Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J
2015-08-01
Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A&M. TAN607 floor plan for first floor. Shows stepped door ...
A&M. TAN-607 floor plan for first floor. Shows stepped door plug design from hot shop into special services cubicle, cubicle windows, and other details. This drawing was re-drawn to show as-built conditions in 1985. Ralph M. Parsons 902-3-ANP-607-A 99. Date of original: January 1955. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106751 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Karcher, D M; Makagon, M M; Fraley, G S; Fraley, S M; Lilburn, M S
2013-03-01
Commercial poultry production management practices have been under increased public scrutiny driven by concerns for food safety and animal welfare. Within the United States, wood shavings and raised plastic floors are common flooring systems used in duck production. It is intuitive that each flooring type would present different management challenges influencing physical characteristics of growing ducks. This study evaluated the relationship between flooring type and duck condition during the winter. Random samples of 20 ducks from 5 predetermined areas (n = 100) were examined in commercial duck houses (n = 9, litter; n = 11, raised plastic slats). Ducks were assessed at 7, 21, and 32 d of age for eye, nostril, and feather cleanliness, feather and foot pad quality, and gait. The data were analyzed to determine the proportion of ducks with a given score. In both housing types, the proportion of 0 scores for foot pad quality improved during the production cycle (P < 0.0001). Feather hygiene declined with age in ducks reared on litter flooring, whereas ducks reared on slatted flooring had cleaner feathers at d 32 (P < 0.011). With the exception of foot pad scores, the majority of ducks had no detectable problems for any single trait. The only main effect due to flooring pertained to feather quality with the proportion of ducks having a 0 or 1 score greater in litter flooring systems than slats (P < 0.05). Overall, the condition of ducks reared, regardless of flooring system, was considered to be good.
A&M. TAN607 first floor plan for cold assembly area. Shows ...
A&M. TAN-607 first floor plan for cold assembly area. Shows special source vaults, X-ray room, instrument shops, and positions of large machines in component test laboratory. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 100. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106752 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Fraley, S M; Fraley, G S; Karcher, D M; Makagon, M M; Lilburn, M S
2013-07-01
The management and well-being of commercial Pekin ducks has been studied in the European Union where straw is the predominant litter source. In the United States, however, the most prevalent litter is wood shavings, with a recent trend toward using plastic slatted flooring. A previous study in the United States evaluated the relationship between flooring type (litter, slats) and duck condition during winter months and found very few differences between the 2 in terms of overall duck condition. The purpose of the current study was to reevaluate the 2 flooring systems during the summer months to determine if seasonal differences would interact with flooring type to have an impact on duck condition. Eighteen commercial barns that produce Pekin ducks for Maple Leaf Farms Inc. (Leesburg, IN), located in northern Indiana and southern Wisconsin (n = 9 litter; n = 9 raised slatted floor), were used for this study. Twenty ducks were randomly selected from 5 predetermined areas within each house (n = 100 total) and scored for eye condition, nostril and feather cleanliness, and feather and foot pad quality at 7, 21, and 32 d of age. Environmental data, including carbon monoxide, ammonia, RH, and temperature, were also obtained at each collection day. The only statistical differences in body condition occurred at 7 d; there were more ducks with clear eyes and eye rings on the litter flooring, whereas average nostril scores were better on the plastic slatted floors. Live weight, weight gain per day, flock mortality, and condemnations at the plant were collected, and the only statistical difference was a higher gain per day for ducks reared on slatted floors compared with litter (P < 0.05). There were no differences between flooring systems in the environmental parameters measured within the barns. In summary, there were very few differences between the litter and slatted flooring systems, indicating that there may not be clear advantages for one particular flooring system over the other from the point of view of duck well-being and production.
Pelvic Floor Muscle Training to Manage Overactive Bladder and Urinary Incontinence.
Angelini, Kimberly
Overactive bladder (OAB) and urinary incontinence (UI) are common chronic conditions that can negatively affect women's quality of life. Pelvic floor muscle training is the first-line treatment. Two recent Cochrane Reviews examining pelvic floor muscle training for the treatment of UI and OAB are summarized here to provide women's health nurses with current recommendations for UI and OAB management. This column also identifies practice improvement education in the area of pelvic floor muscle training and treatment for OAB and UI. © 2017 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.
Kennedy, Peter G; Schouboe, Jesse L; Rogers, Rachel H; Weber, Marjorie G; Nadkarni, Nalini M
2010-02-01
The ecological importance of microbial symbioses in terrestrial soils is widely recognized, but their role in soils that accumulate in forest canopies is almost entirely unknown. To address this gap, this study investigated the Frankia-Alnus rubra symbiosis in canopy and forest floor roots at Olympic National Park, WA, USA. Sixteen mature A. rubra trees were surveyed and Frankia genetic diversity in canopy and forest floor nodules was assessed with sequence-based nifH analyses. A seedling bioassay experiment was conducted to determine Frankia propagule availability in canopy and forest floor soils. Total soil nitrogen from both environments was also quantified. Nodules were present in the canopies of nine of the 16 trees sampled. Across the study area, Frankia canopy and forest floor assemblages were similar, with both habitats containing the same two genotypes. The composition of forest floor and canopy genotypes on the same tree was not always identical, however, suggesting that dispersal was not a strictly local phenomenon. Frankia seedling colonization was similar in canopy soils regardless of the presence of nodules as well as in forest floor soils, indicating that dispersal was not likely to be a major limiting factor. The total soil nitrogen of canopy soils was higher than that of forest floor soils, but the presence of Frankia nodules in canopy soils did not significantly alter soil nitrogen levels. Overall, this study indicates that the Frankia-A. rubra symbiosis is similar in canopy and forest floor environments. Because canopy roots are exposed to different environmental conditions within very small spatial areas and because those areas can be easily manipulated (e.g., fertilizer or watering treatments), they present microbial ecologists with a unique arena to examine root-microbe interactions.
Hashiguchi, Nobuko; Tochihara, Yutaka; Ohnaka, Tadakatsu; Tsuchida, Chiaki; Otsuki, Tamio
2004-11-01
The purpose of this study was to investigate the effects of a floor heating and air conditioning system on thermal responses of the elderly. Eight elderly men and eight university students sat for 90 minutes in a chair under the following 3 conditions: air conditioning system (A), floor heating system (F) and no heating system (C). The air temperature of sitting head height for condition A was 25 degrees C, and the maximum difference in vertical air temperature was 4 degrees C. The air and floor temperature for condition F were 21 and 29 degrees C, respectively. The air temperature for condition C was 15 degrees C. There were no significant differences in rectal temperature and mean skin temperature between condition A and F. Systolic blood pressure of the elderly men in condition C significantly increased compared to those in condition A and F. No significant differences in systolic blood pressure between condition A and F were found. The percentage of subjects who felt comfortable under condition F was higher than that of those under condition A in both age groups, though the differences between condition F and A was not significant. Relationships between thermal comfort and peripheral (e.g., instep, calf, hand) skin temperature, and the relationship between thermal comfort and leg thermal sensation were significant for both age groups. However, the back and chest skin temperature and back thermal sensation for the elderly, in contrast to that for the young, was not significantly related to thermal comfort. These findings suggested that thermal responses and physiological strain using the floor heating system did not significantly differ from that using the air conditioning system, regardless of the subject age and despite the fact that the air temperature with the floor heating system was lower. An increase in BP for elderly was observed under the condition in which the air temperature was 15 degrees C, and it was suggested that it was necessary for the elderly people to heat the room somehow in winter. Moreover, it is particularly important for elderly people to avoid a decrease in peripheral skin temperature, and maintain awareness of the warmth of peripheral areas, such as the leg, in order to ensure thermal comfort.
A&M. TAN607 second floor plan for hot shop. Roof of ...
A&M. TAN-607 second floor plan for hot shop. Roof of pool. Viewing window locations. Special equipment room. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 101. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106753 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Ryan, D.F.; Huntington, T.G.; Wayne, Martin C.
1992-01-01
To investigate whether mechanical mixing during harvesting could account for losses observed from forest floor, we measured surface disturbance on a 22 ha watershed that was whole-tree harvested. Surface soil on each 10 cm interval along 81, randomly placed transects was classified immediately after harvesting as mineral or organic, and as undisturbed, depressed, rutted, mounded, scarified, or scalped (forest floor scraped away). We quantitatively sampled these surface categories to collect soil in which preharvest forest floor might reside after harvest. Mechanically mixed mineral and organic soil horizons were readily identified. Buried forest floor under mixed mineral soil occurred in 57% of mounds with mineral surface soil. Harvesting disturbed 65% of the watershed surface and removed forest floor from 25% of the area. Mechanically mixed soil under ruts with organic or mineral surface soil, and mounds with mineral surface soil contained organic carbon and nitrogen pools significantly greater than undisturbed forest floor. Mechanical mixing into underlying mineral soil could account for the loss of forest floor observed between the preharvest condition and the second growing season after whole-tree harvesting. ?? 1992.
Krebs, N; Berry, S L; Tucker, C B
2011-01-01
Interest in the use of rubber flooring in freestall barns has increased, but little is known about which design features of these surfaces are important for cattle. In 2 experiments, we evaluated how the type and compressibility of the flooring surface in front of the feed bunk influenced the behavioral response to 4 h of forced standing after morning milking. Two flooring types were compared: rubber and concrete. Rubber was tested at 3 levels of compressibility: 2, 4, and 35 times as compressible as concrete. Four hours of forced standing was evaluated because it mimicked conditions that can occur on dairies, particularly when waiting for artificial insemination or veterinary treatment. The effects of cow weight and hoof surface area, gait score, and hoof health on the response to treatment were evaluated. Restless behavior, as measured by number of steps, almost doubled over the 4h of forced standing, regardless of flooring material. Cows lay down, on average, within 5 min after access to the lying area was provided. These results indicate that the 4 h of forced standing was uncomfortable. No differences in restless behavior were observed in association with the type or compressibility of the flooring surface in front of the feed bunk. Cow size, hoof health, or gait score did not consistently explain the response to the flooring treatments or stepping rate, although these populations of animals were generally healthy. It is unclear if comfort did not differ between the flooring options tested during 4 h of forced standing or if alterative methodology, such as measuring more subtle shifts in weight, is required to assess design features of rubber flooring. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Subjective assessments of floor slipperiness before and after walk under two lighting conditions.
Li, Kai Way; Zhao, Caijun; Peng, Lu; Liu, Ai-Qun
2018-06-01
A gait experiment was performed. The participants were tested under shoes, floors, surface and lighting conditions. They gave floor slipperiness ratings before and after a gait trial. The perceived sense of slip (PSOS) was collected. It was found that the perceived floor slipperiness (PFS) before walking was affected significantly by the lighting, floor and surface conditions. Relative low PFS values were recorded under wet and detergent-contaminated conditions in the normal daylight condition as compared with those in the dimmed condition. The PFS after the gait was significantly affected by the floor and surface conditions. The PSOS was highly correlated with the PFS after trial. The regression analyses results indicated that both the coefficient of friction (COF) of the floor and lighting were primary predictors of the PFS before a gait. The COF and walking speed were the primary predictors of the PFS after a gait.
D'Souza, Clive; Paquet, Victor; Lenker, James A; Steinfeld, Edward
2017-07-01
The emergence of low-floor bus designs and related regulatory standards in the U.S. have resulted in substantial improvements in public transit accessibility. However, passengers using wheeled mobility devices still experience safety concerns and inefficiencies in boarding, disembarking, and interior circulation on low-floor buses. This study investigates effects of low-floor bus interior configuration and passenger crowding on boarding and disembarking efficiency and safety. Users of manual wheelchairs (n = 18), powered wheelchairs (n = 21) and electric scooters (n = 9) simulated boarding and disembarking in three interior layout configurations at low and high passenger crowding conditions on a full-scale laboratory mock-up of a low-floor bus. Dependent measures comprised task times and critical incidents during access ramp use, fare payment, and movement to and from the doorway and wheeled mobility securement area. Individual times for unassisted boarding ranged from 15.2 to 245.3 s and for disembarking ranged from 9.1 to 164.6 s across layout and passenger crowding conditions. Nonparametric analysis of variance showed significant differences and interactions across vehicle design conditions, passenger load and mobility device type on user performance. The configuration having electronic on-board fare payment, rear-bus entrance doorways and adjacent device securement areas demonstrated greatest efficiency and safety. High passenger load adversely impacted efficiency and frequency of critical incidents during on-board circulation across all three layouts. Findings have broader implications for improving transit system efficiency and quality of service across the spectrum of transit users. Copyright © 2017 Elsevier Ltd. All rights reserved.
Modality dependence and intermodal transfer in the Corsi Spatial Sequence Task: Screen vs. Floor.
Röser, Andrea; Hardiess, Gregor; Mallot, Hanspeter A
2016-07-01
Four versions of the Corsi Spatial Sequence Task (CSST) were tested in a complete within-subject design, investigating whether participants' performance depends on the modality of task presentation and reproduction that put different demands on spatial processing. Presentation of the sequence (encoding phase) and the reproduction (recall phase) were each carried out either on a computer screen or on the floor of a room, involving actual walking in the recall phase. Combinations of the two different encoding and recall procedures result in the modality conditions Screen-Screen, Screen-Floor, Floor-Screen, and Floor-Floor. Results show the expected decrease in performance with increasing sequence length, which is likely due to processing limitations of working memory. We also found differences in performance between the modality conditions indicating different involvements of spatial working memory processes. Participants performed best in the Screen-Screen modality condition. Floor-Screen and Floor-Floor modality conditions require additional working memory resources for reference frame transformation and spatial updating, respectively; the resulting impairment of the performance was about the same in these two conditions. Finally, the Screen-Floor modality condition requires both types of additional spatial demands and led to the poorest performance. Therefore, we suggest that besides the well-known spatial requirements of CSST, additional working memory resources are demanded in walking CSST supporting processes such as spatial updating, mental rotation, reference frame transformation, and the control of walking itself.
Aided Electrophysiology Using Direct Audio Input: Effects of Amplification and Absolute Signal Level
Billings, Curtis J.; Miller, Christi W.; Tremblay, Kelly L.
2016-01-01
Purpose This study investigated (a) the effect of amplification on cortical auditory evoked potentials (CAEPs) at different signal levels when signal-to-noise ratios (SNRs) were equated between unaided and aided conditions, and (b) the effect of absolute signal level on aided CAEPs when SNR was held constant. Method CAEPs were recorded from 13 young adults with normal hearing. A 1000-Hz pure tone was presented in unaided and aided conditions with a linear analog hearing aid. Direct audio input was used, allowing recorded hearing aid noise floor to be added to unaided conditions to equate SNRs between conditions. An additional stimulus was created through scaling the noise floor to study the effect of signal level. Results Amplification resulted in delayed N1 and P2 peak latencies relative to the unaided condition. An effect of absolute signal level (when SNR was constant) was present for aided CAEP area measures, such that larger area measures were found at higher levels. Conclusion Results of this study further demonstrate that factors in addition to SNR must also be considered before CAEPs can be used to clinically to measure aided thresholds. PMID:26953543
ERIC Educational Resources Information Center
Morrow, Hugh
1997-01-01
Examines the decision-making factors when selecting school flooring. Areas to consider include what the area being covered is used for and the flooring's life-cycle costing. Suggestions on the types of flooring to consider are offered, as are tips on buying flooring made of recycled materials, and considerations for making the best overall…
Heerkens, Jasper L T; Delezie, Evelyne; Kempen, Ine; Zoons, Johan; Ampe, Bart; Rodenburg, T Bas; Tuyttens, Frank A M
2015-09-01
Feather pecking and high mortality levels are significant welfare problems in non-cage housing systems for laying hens. The aim of this study was to identify husbandry-related risk factors for feather damage, mortality, and egg laying performance in laying hens housed in the multi-tier non-cage housing systems known as aviaries. Factors tested included type of system flooring, degree of red mite infestation, and access to free-range areas. Information on housing characteristics, management, and performance in Belgian aviaries (N=47 flocks) were obtained from a questionnaire, farm records, and farm visits. Plumage condition and pecking wounds were scored in 50 randomly selected 60-week-old hens per flock. Associations between plumage condition, wounds, performance, mortality, and possible risk factors were investigated using a linear model with a stepwise model selection procedure. Many flocks exhibited a poor plumage condition and a high prevalence of wounds, with considerable variation between flocks. Better plumage condition was found in wire mesh aviaries (P<0.001), in aviaries with no red mite infestation (P=0.004), and in free-range systems (P=0.011) compared to plastic slatted aviaries, in houses with red mite infestations, and those without a free-range area. Furthermore, hens in aviaries with wire mesh flooring had fewer wounds on the back (P=0.006) and vent (P=0.009), reduced mortality (P=0.003), and a better laying performance (P=0.013) as compared to hens in aviaries with plastic slatted flooring. Flocks with better feather cover had lower levels of mortality (P<0.001). Red mite infestations were more common in plastic slatted aviaries (P=0.043). Other risk factors associated with plumage condition were genotype, number of diet changes, and the presence of nest perches. Wire mesh flooring in particular seems to have several health, welfare, and performance benefits in comparison to plastic slats, possibly related to decreased feather pecking, better hygiene, and fewer red mite infestations. This suggests that adjustments to the aviary housing design may further improve laying hen welfare and performance. © 2015 Poultry Science Association Inc.
De Palo, P; Tateo, A; Zezza, F; Corrente, M; Centoducati, P
2006-12-01
An evaluation of behavioral and hygienic conditions was carried out with 4 materials used as free-stall flooring for dairy cows: polyethylene vinyl acetate (EVA) and polypropylene vinyl acetate (PVA) mats, wood shavings, and solid manure. The free-stall type selected by cows was evaluated in response to changes in environmental temperature and humidity. Two tests were used: 1) a preference test, in which 8 cows were housed in a pen with 32 free stalls and 4 types of flooring; and 2) an aversion test, in which 32 cows were placed in 4 pens, each with 8 free stalls. The free stalls in each pen had a single type of bedding material. These tests showed that the comfort of dairy cows was predominantly influenced by environmental conditions. The preference test for lying showed that cows preferred free-stall floors with EVA mats over those with PVA mats, wood shavings, and solid manure (332.4 +/- 24.0 vs. 130.8 +/- 6.2, 160.9 +/- 23.7, and 102.6 +/- 23.2 min/d, respectively), but under conditions of heat stress, with a temperature-humidity index > 80, they chose wood shavings and solid manure lying areas. These results were confirmed by the aversion test. In all experimental and environmental conditions, the PVA mats were the least suitable. The mats contaminated with organic manure and the free stalls bedded with wood shavings and organic solids did not differ in either the coliform load on the lying surfaces (EVA mats: 290 +/- 25; PVA mats: 306 +/- 33; wood shavings: 290 +/- 39; and solid manure: 305 +/- 23 log(10) cfu/mL) or the total bacterial count in the raw milk (EVA mats: 232 +/- 22; PVA mats: 233 + 24; wood shavings: 221 +/- 24; and solid manure: 220 +/- 25 log(10) cfu/mL). These results demonstrate that the comfort of dairy cows housed in barns with free stalls as resting areas does not depend only on the material used, but also on the value of the material in microenvironmental conditions.
A first generation dynamic ingress, redistribution and transport model of soil track-in: DIRT.
Johnson, D L
2008-12-01
This work introduces a spatially resolved quantitative model, based on conservation of mass and first order transfer kinetics, for following the transport and redistribution of outdoor soil to, and within, the indoor environment by track-in on footwear. Implementations of the DIRT model examined the influence of room size, rug area and location, shoe size, and mass transfer coefficients for smooth and carpeted floor surfaces using the ratio of mass loading on carpeted to smooth floor surfaces as a performance metric. Results showed that in the limit for large numbers of random steps the dual aspects of deposition to and track-off from the carpets govern this ratio. Using recently obtained experimental measurements, historic transport and distribution parameters, cleaning efficiencies for the different floor surfaces, and indoor dust deposition rates to provide model boundary conditions, DIRT predicts realistic floor surface loadings. The spatio-temporal variability in model predictions agrees with field observations and suggests that floor surface dust loadings are constantly in flux; steady state distributions are hardly, if ever, achieved.
Benchmark for Performance: Geothermal Applications in Lincoln Public Schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durfee, D.J.; Hughes, P.J.; Martin, M.A.
1999-06-19
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident among the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
Benchmark for performance: Geothermal applications in Lincoln public schools
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shonder, J.A.; Martin, M.A.; Sharp, T.R.
1999-07-01
Vertical-bore, geothermal heat pumps (GHPs) have been providing heating and cooling to four new elementary schools located in Lincoln, Nebraska since 1995. According to representatives of the local utility and school district, the systems are providing a comfortable, complaint-free environment with utility costs that are nearly half of that of other schools in the district. Performance data collected from on-site energy management systems and district billing and utility records for all fifty schools in the Lincoln district indicate that only five consume less energy than the best performing GHP school; however, these five cool less than 10% of their totalmore » floor area, while the GHP schools cool 100% of their floor area. When compared to other new schools (with similar ventilation loads), the GHP schools used approximately 26% less source energy per square foot of floor area. Variations in annual energy performance are evident amongst the four GHP schools, however, together they still consume less source energy than 70% of all schools in the district. These variations are most likely due to operational differences rather than installed equipment, building orientation, or environmental (bore field) conditions.« less
Buffing, burnishing, and stripping of vinyl asbestos floor tile
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollett, B.A.; Edwards, A.; Clark, P.J.
Studies were conducted to evaluate airborne asbestos concentrations during the three principal types of preventative maintenance (low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping) used on asbestos-containing floor tiles. These were done under pre-existing and prepared levels of floor care maintenance. Airborne asbestos concentrations were measured before and during each floor care procedure to determine the magnitude of the increase in airborne asbestos levels during each procedure. Airborne total fiber concentrations were also measured for comparison with the Occupational Safety and Health Administration`s (OSHA) Permissible Exposure Limit (PEL) of 0.1 f/cm{sup 3}. Low-speed spray-buffing and wet-stripping were evaluated on pre-existing floormore » conditions and three levels of prepared floor care conditions (poor, medium, and good). Ultra high-speed burnishing and wet-stripping were evaluated on two levels of prepared floor care conditions (poor and good). Floor care conditions were defined in consultation with the Chemical Specialty Manufacturers Association and other representatives of floor-care chemical manufacturers. Controlled studies were conducted in an unoccupied building at the decommissioned Chanute Air Force Base in Rantoul, Illinois, with the cooperation of the U.S. Air Force. The building offered approximately 8600 ft{sup 2} of open floor space tiled with 9-inch by 9-inch resilient floor tile containing approximately 5% chrysotile asbestos.« less
41 CFR 102-80.145 - What is meant by “flashover”?
Code of Federal Regulations, 2010 CFR
2010-07-01
...”? Flashover means fire conditions in a confined area where the upper gas layer temperature reaches 600 °C (1100 °F) and the heat flux at floor level exceeds 20 kW/m2 (1.8 Btu/ft2/sec). Reasonable Worst Case...
41 CFR 102-80.145 - What is meant by “flashover”?
Code of Federal Regulations, 2011 CFR
2011-01-01
...”? Flashover means fire conditions in a confined area where the upper gas layer temperature reaches 600 °C (1100 °F) and the heat flux at floor level exceeds 20 kW/m2 (1.8 Btu/ft2/sec). Reasonable Worst Case...
Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions.
van Raalte, Heather; Egorov, Vladimir
2015-08-01
The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions ( p < 0.05 for one-way ANOVA and/or p < 0.05 for t -test with correlation factor r from -0.73 to -0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse.
Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions
van Raalte, Heather; Egorov, Vladimir
2015-01-01
The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions (p < 0.05 for one-way ANOVA and/or p < 0.05 for t-test with correlation factor r from −0.73 to −0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse. PMID:26389014
Friction between footwear and floor covered with solid particles under dry and wet conditions.
Li, Kai Way; Meng, Fanxing; Zhang, Wei
2014-01-01
Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.
This School Is for Kids and Community.
ERIC Educational Resources Information Center
American School Board Journal, 1982
1982-01-01
In Avon (Indiana), a community lacking public buildings, a middle school was built with community uses in mind. The swimming pool, gymnasium, and commons area can be blocked off for community use by using floor-to-ceiling gates. The school's heating, ventilating, and air conditioning systems are also energy-efficient. (Author/MLF)
A&M. TAN607 floor plans. Shows three floor levels of pool, ...
A&M. TAN-607 floor plans. Shows three floor levels of pool, hot shop, and warm shop. Includes view of pool vestibule, personnel labyrinth, location of floor rails, and room numbers of office areas, labs, instrument rooms, and stairways. This drawing was re-drawn to show as-built features in 1993. Ralph M. Parsons 902-3-ANP-607-A 96. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106748 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
The influence of novel compliant floors on balance control in elderly women--A biomechanical study.
Wright, Alexander D; Laing, Andrew C
2011-07-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (SmartCell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard 'Rigid' floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
The influence of novel compliant floors on balance control in elderly women—A biomechanical study
Wright, Alexander D.; Laing, Andrew C.
2012-01-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (Smart-Cell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard ‘Rigid’ floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. PMID:21545881
Sea-floor morphology and sedimentary environments in southern Narragansett Bay, Rhode Island
McMullen, Katherine Y.; Poppe, Lawrence J.; Blackwood, Dann S.; Nardi, Matthew J.; Andring, Matthew A.
2015-09-09
Multibeam echosounder data collected by the National Oceanic and Atmospheric Administration along with sediment samples and still and video photography of the sea floor collected by the U.S. Geological Survey were used to interpret sea-floor features and sedimentary environments in southern Narragansett Bay, Rhode Island, as part of a long-term effort to map the sea floor along the northeastern coast of the United States. Sea-floor features include rocky areas and scour depressions in high-energy environments characterized by erosion or nondeposition, and sand waves and megaripples in environments characterized by coarse-grained bedload transport. Two shipwrecks are also located in the study area. Much of the sea floor is relatively featureless within the resolution of the multibeam data; sedimentary environments in these areas are characterized by processes associated with sorting and reworking. This report releases bathymetric data from the multibeam echosounder, grain-size analyses of sediment samples, and photographs of the sea floor and interpretations of the sea-floor features and sedimentary environments. It provides base maps that can be used for resource management and studies of topics such as benthic ecology, contaminant inventories, and sediment transport.
Postfire rehabilitation treatments: are we learning what works?
P. R. Robichaud; R. E. Brown
2005-01-01
Major concerns after wildfires are the increased erosion and flooding potential due to loss of the protective forest floor layer, loss of water storage, and the creation of water repellent soil conditions. Treatments to mitigate postfire erosion and runoff are commonly applied on highly erodible areas; however the effectiveness of these treatments has had limited...
Code of Federal Regulations, 2010 CFR
2010-04-01
... domestic water, electrical system, elevators, emergency power, fire protection, HVAC, and sanitary system... applicable), ceiling, doors, electrical systems, floors, hot water heater, HVAC (where individual units are... standards address the major areas of the HUD housing: the site; the building exterior; the building systems...
Code of Federal Regulations, 2012 CFR
2012-04-01
... domestic water, electrical system, elevators, emergency power, fire protection, HVAC, and sanitary system... applicable), ceiling, doors, electrical systems, floors, hot water heater, HVAC (where individual units are... standards address the major areas of the HUD housing: the site; the building exterior; the building systems...
Code of Federal Regulations, 2014 CFR
2014-04-01
... domestic water, electrical system, elevators, emergency power, fire protection, HVAC, and sanitary system... applicable), ceiling, doors, electrical systems, floors, hot water heater, HVAC (where individual units are... standards address the major areas of the HUD housing: the site; the building exterior; the building systems...
Code of Federal Regulations, 2013 CFR
2013-04-01
... domestic water, electrical system, elevators, emergency power, fire protection, HVAC, and sanitary system... applicable), ceiling, doors, electrical systems, floors, hot water heater, HVAC (where individual units are... standards address the major areas of the HUD housing: the site; the building exterior; the building systems...
MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR FIRST FLOOR: MACHINE ...
MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR FIRST FLOOR: MACHINE SHOP, ELECTRICAL AND INSTRUMENT SHOP, TOOL CRIB, ELECTRONIC SHOP, LOCKER ROOM, SPECIAL TEMPERATURE CONTROLLED ROOM, AND OFFICES. "NEW" ON DRAWING REFERS TO REVISION OF 11/1956 DRAWING ON WHICH AREAS WERE DESIGNATED AS "FUTURE." HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-7, 5/1957. INL INDEX NO. 532-0653-00-381-101839, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
45. PRODUCTION AREA, GROUND FLOOR, EAST WING. GLAZE MIXING AREA ...
45. PRODUCTION AREA, GROUND FLOOR, EAST WING. GLAZE MIXING AREA IN THE RIGHT BACKGROUND, COURTYARD THROUGH THE DOORWAY TO THE LEFT. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA
Cooper, Alan; Twichell, David; Hart, Patrick
1999-01-01
During April 1999, the U.S. Geological Survey (USGS) conducted a 13-day cruise in the Garden Banks and Green Canyon regions of the Gulf of Mexico. The R/V Gyre, owned by Texas A&M University, was chartered for the cruise. The general objectives were (1) to acquire very high resolution seismic-reflection data and side-scan sonar images of the upper and middle continental slope (200-1200-m water depths), (2) to study the acoustic character and features of the sea floor for evidence of sea-floor hazards, and (3) to look for evidence of subsurface gas hydrates and their effects. The Gulf of Mexico is well known for hydrocarbon resources, with emphasis now on frontier deep-water areas. For water depths greater than about 250 m, the pressure-termperature conditions are correct for the development of shallow-subsurface gas hydrate formation (Anderson et al., 1992). Gas hydrates are ice-like mixtures of gas and water (Kvenvolden, 1993). They are known to be present from extensive previous sampling in sea-floor cores and from mound-like features observed on the sea floor in many parts of the northern Gulf, including the Green Canyon and Garden Banks areas (e.g., Roberts, 1995). Seismic-reflection data are extensive in the Gulf of Mexico, but few very-high-resolution data like those needed for gas-hydrate studies exist in the public domain. The occurrence and mechanisms of gas hydrate formation and dissociation are important to understand, because of their perceived economic potential for methane gas, their potential controls on local and regional sea-floor stability, and their possible effects on earth climates due to massive release of methane greenhouse gas into the atmosphere. Three high-resolution seismic-reflection systems and one side-scan sonar system were used on the cruise to map the surface reflectance and features of the sea floor and the acoustic geometries and character of the shallow sub-surface. The cruise was designed to acquire regional and detailed local information. The regional survey covered an area about 3400 km2 in the Green Canyon and Garden Banks regions. Data recorded included 15 cu. in. water gun multichannel seismic-reflection and Huntec boomer information. Detailed surveys were planned in two parts of the study area, but due to a winch failure only one detailed survey was done in the Green Canyon area. The detailed survey included collection of 15 cu. in. water gun multichannel seismic-reflection, chirp seismic-reflection, and side-scan data.
Sea-floor geology of Long Island Sound north of Duck Pond Point, New York
McMullen, K.Y.; Poppe, L.J.; Danforth, W.W.; Blackwood, D.S.; Schaer, J.D.; Glomb, K.A.; Doran, E.F.
2012-01-01
The U.S. Geological Survey, the National Oceanic and Atmospheric Administration (NOAA), and the Connecticut Department of Environmental Protection are mapping the sea floor in coastal areas of the northeastern United States. As part of the project, more than 100 square kilometers of multibeam-echosounder data, 23 sediment samples, bottom video, and 86 still photographs were obtained from an area in Long Island Sound north of Duck Pond Point, New York, in the study area of NOAA survey H11999. This report delineates the sediment types and sea-floor features found within this area in order to better understand the sea-floor processes occurring in this part of Long Island Sound. The sea floor in the study area is dominated by ubiquitous sand-wave fields and three northeast-southwest trending bathymetric depressions. Barchanoid and transverse sand waves, including sinusoidal, bifurcating, arced, and straight-crested morphologies, are variably present. Asymmetrical sand-wave profiles indicate a westward to southwestward direction of sediment transport in most of the study area; current ripples and megaripples on the stoss slopes of the sand waves indicate transport is ongoing. The majority of the sediment on the sea floor is sand, although bouldery, gravelly, and muddy sediments are also present. Gray, cohesive mud crops out on the walls of some of the scour depressions associated with the troughs of large sand waves. Clasts of the muddy sediment scattered on the sea floor around the depressions demonstrate the intensity of the scour and suggest erosion of the underlying distal deltaic sediments.
DeepSurveyCam--A Deep Ocean Optical Mapping System.
Kwasnitschka, Tom; Köser, Kevin; Sticklus, Jan; Rothenbeck, Marcel; Weiß, Tim; Wenzlaff, Emanuel; Schoening, Timm; Triebe, Lars; Steinführer, Anja; Devey, Colin; Greinert, Jens
2016-01-28
Underwater photogrammetry and in particular systematic visual surveys of the deep sea are by far less developed than similar techniques on land or in space. The main challenges are the rough conditions with extremely high pressure, the accessibility of target areas (container and ship deployment of robust sensors, then diving for hours to the ocean floor), and the limitations of localization technologies (no GPS). The absence of natural light complicates energy budget considerations for deep diving flash-equipped drones. Refraction effects influence geometric image formation considerations with respect to field of view and focus, while attenuation and scattering degrade the radiometric image quality and limit the effective visibility. As an improvement on the stated issues, we present an AUV-based optical system intended for autonomous visual mapping of large areas of the seafloor (square kilometers) in up to 6000 m water depth. We compare it to existing systems and discuss tradeoffs such as resolution vs. mapped area and show results from a recent deployment with 90,000 mapped square meters of deep ocean floor.
Sran, Meena M; Robinovitch, Stephen N
2008-08-01
In vivo biomechanical study of 11 male volunteers. To measure the peak forces applied to the buttocks in a backward fall from standing, and to determine whether this force is lowered by reductions in floor stiffness. Fall-related vertebral fractures are common and backward falls result in impact to the buttocks. Compliant flooring may reduce impact force and risk for vertebral fracture during a fall. However, we have little knowledge of the peak forces applied to the body during a backward fall, or how floor stiffness affects this force. Eleven males, mean age 25 +/- 5 (SD) years, were suddenly released from a backward lean of 15 degrees , falling backward onto the ground which was covered with 4.5, 7.5, or 10.5 cm of ethylene vinyl acetate foam rubber. We measured 3-dimensional impact forces applied to the buttocks at 960 Hz with a force plate. We used repeated measures analysis of variance and post hoc t tests to compare peak forces between conditions. We also modeled peak vertical force for falls onto a bare floor. RESULTS.: There was a significant difference in peak vertical force between falls onto the 10.5 cm foam condition compared with the 7.5 cm (P = 0.002) and 4.5 cm (P < 0.001) conditions. Peak vertical force (N) was (mean +/- SD) 5099 +/- 868, 4788 +/- 702, and 4544 +/- 672 for the 4.5, 7.5, and 10.5 cm foam conditions, respectively, and estimated at 6027 +/- 988 for the rigid (bare floor) condition. Compared with the bare floor, these foam floors provided, on average, 24, 20, and 15% force attenuation respectively. In a backward fall onto the buttocks, peak impact forces are 6.4 to 9.0 times body weight in a fall onto a bare floor. Reducing floor stiffness using even a thin (4.5 cm) layer of foam may provide 15% vertical force attenuation during a fall onto the buttocks.
INTERIOR SECOND FLOOR EAST ENGINEERING DESIGN AREA DETAIL VIEW, FACING ...
INTERIOR SECOND FLOOR EAST ENGINEERING DESIGN AREA DETAIL VIEW, FACING NORTH. - NASA Industrial Plant, Systems Integration & Checkout Facility, 12214 Lakewood Boulevard, Downey, Los Angeles County, CA
33. Second floor, detail of plumbing access area Veterans ...
33. Second floor, detail of plumbing access area - Veterans Administration Center, Officers Duplex Quarters, 5302 East Kellogg (Legal Address); 5500 East Kellogg (Common Address), Wichita, Sedgwick County, KS
13. VIEW INTO BLOCK AREA SHOWING KEY MECHANISM, NOTE FLOOR ...
13. VIEW INTO BLOCK AREA SHOWING KEY MECHANISM, NOTE FLOOR SEPARATION AT THRESHOLD AND KEY-WINDING MECHANISM - Montgomery County Jail, Washington & Spring Streets, Crawfordsville, Montgomery County, IN
The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.
de Boer, Rob
2003-01-01
It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.
Interior view of second floor sleeping area; camera facing south. ...
Interior view of second floor sleeping area; camera facing south. - Mare Island Naval Shipyard, Marine Barracks, Cedar Avenue, west side between Twelfth & Fourteenth Streets, Vallejo, Solano County, CA
Li, Kai Way; Chen, Chin Jung
2004-11-01
Tread groove design is very common in footwear. However, coefficient of friction (COF) measurements between the footwear material and floor using a slipmeter were commonly performed using flat footwear pads. Such measurements might underestimate the actual slip resistance of the footwear pad. This research investigates the effects of the tread groove width on the measured COF using four footwear materials, three floors, and four liquid-contamination conditions using a Brungraber Mark II slipmeter. The analysis of variance results indicated that the footwear material, floor, contamination conditions, and groove width were all significant (p < 0.0001) factors affecting the measured COF. The hypothesis that wider tread grooves result in higher COF values was true with some exceptions especially on oil contaminated floors. A regression model, with an R2 of 0.91, was established to describe and predict the relationship between the COF and the tread groove width under footwear material/floor/contamination conditions.
What Will Science Gain From Mapping the World Ocean Floor?
NASA Astrophysics Data System (ADS)
Jakobsson, M.
2017-12-01
It is difficult to estimate how much of the World Ocean floor topography (bathymetry) that has been mapped. Estimates range from a few to more than ten percent of the World Ocean area. The most recent version of the bathymetric grid compiled by the General Bathymetric Chart of the Oceans (GEBCO) has bathymetric control points in 18% of the 30 x 30 arc second large grid cells. The depth values for the rest of the cells are obtained through interpolation guided by satellite altimetry in deep water. With this statistic at hand, it seems tenable to suggest that there are many scientific discoveries to be made from a complete high-resolution mapping of the World Ocean floor. In this presentation, some of our recent scientific discoveries based on modern multibeam bathymetric mapping will be highlighted and discussed. For example, how multibeam mapping provided evidence for a km-thick ice shelf covering the entire Arctic Ocean during peak glacial conditions, a hypothesis proposed nearly half a century ago, and how groundwater escape features are visible in high-resolution bathymetry in the Baltic Sea, with potential implications for the freshwater budget and distribution of nutrients and pollutants. Presented examples will be placed in the context of mapping resolution, systematic surveys versus mapping along transits, and scientific hypothesis driven mapping versus ocean exploration. The newly announced Nippon Foundation - GEBCO Seabed 2030 project has the vision to map 100% of the World Ocean floor mapped by 2030. Are there specific scientific areas where we can expect new discoveries from all mapping data collected through the Seabed 2030 project? Are there outstanding hypothesis that can be tested from a fully mapped World Ocean floor?
ETR ELECTRICAL BUILDING, TRA648. FLOOR PLANS FOR FIRST FLOOR AND ...
ETR ELECTRICAL BUILDING, TRA-648. FLOOR PLANS FOR FIRST FLOOR AND BASEMENT. SECTIONS. KAISER ETR-5528-MTR-648-A-2, 12/1955. INL INDEX NO. 532-0648-00-486-101402, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
36 CFR 1192.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Floors, steps and thresholds... Light Rail Vehicles and Systems § 1192.79 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and mobility aid users are to be...
49 CFR 38.79 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.79 Section 38.79... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...
49 CFR 38.99 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads, places for standees, and areas where wheelchair and...
49 CFR 38.117 - Floors, steps and thresholds.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.117 Section 38...) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.117 Floors, steps and thresholds. (a) Floor surfaces on aisles, step treads and areas where wheelchair and mobility aid...
11. Interior view, second floor, tin shop area looking southwest, ...
11. Interior view, second floor, tin shop area looking southwest, showing laminated plank arched roof trusses. - Larrabee & Hingston Company, Main Shop Building, 19 Howley Street, Peabody, Essex County, MA
Refrigeration Plant, North Elevation, Second Floor Plan, East Elevation, Ground ...
Refrigeration Plant, North Elevation, Second Floor Plan, East Elevation, Ground Floor Plan, Section A-A - Kennecott Copper Corporation, On Copper River & Northwestern Railroad, Kennicott, Valdez-Cordova Census Area, AK
131. ARAII Administration building (ARA613) floor plans for first and ...
131. ARA-II Administration building (ARA-613) floor plans for first and second floors. Includes roof plan. Shows use of rooms as offices, laboratory, conference room. F.C. Torkelson Company 842-area/SL-1-613-A-1. Date: October 1958. Ineel index code no. 070-0613-00-851-150718. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Effect of flooring on standing comfort and fatigue.
Cham, R; Redfern, M S
2001-01-01
This study investigated the influence of flooring on subjective discomfort and fatigue during standing and on potentially related objective measures. Participants stood for 4 h on each of 7 flooring conditions while performing computer tasks. During the 3rd and 4th h, floor type had a significant effect on a number of subjective ratings, including lower-leg and lower-back discomfort/fatigue and 2 of 4 objective variables (center of pressure weight shift and lower-extremity skin temperature). In addition, lower-leg volumetric measurements showed tendencies toward greater lower-extremity swelling on uncomfortable floors. The hard floor and 1 floor mat condition consistently had the worst discomfort/fatigue and objective ratings. Significant relationships were noted between the affected subjective ratings and objective variables. In general, floor mats characterized by increased elasticity, decreased energy absorption, and increased stiffness resulted in less discomfort and fatigue. Thus flooring properties do affect low-back and lower-leg discomfort/fatigue, but the result may be detectable only after 3 h of standing. Potential applications of this research include the reduction of work-related health problems associated with long-term standing.
ERIC Educational Resources Information Center
Schmid, Sue
1994-01-01
Describes the benefits of using rubber floor coverings in a gym's free-weight and cardiovascular equipment areas. Tips on purchasing a rubber floor are highlighted as is an annotated list of suppliers and their rubber flooring products. (GR)
Motor cortical representation of the pelvic floor muscles.
Schrum, A; Wolff, S; van der Horst, C; Kuhtz-Buschbeck, J P
2011-07-01
Pelvic floor muscle training involves rhythmical voluntary contractions of the external urethral sphincter and ancillary pelvic floor muscles. The representation of these muscles in the motor cortex has not been located precisely and unambiguously. We used functional magnetic resonance imaging to determine brain activity during slow and fast pelvic floor contractions. Cerebral responses were recorded in 17 healthy male volunteers, 21 to 47 years old, with normal bladder control. Functional magnetic resonance imaging was performed during metronome paced slow (0.25 Hertz) and fast (0.7 Hertz) contractions of the pelvic floor that mimicked the interruption of voiding. To study the somatotopy of the cortical representations, flexion-extension movements of the right toes were performed as a control task. Functional magnetic resonance imaging during pelvic floor contractions detected activity of the supplementary motor area in the medial wall and of the midcingulate cortex, insula, posterior parietal cortex, putamen, thalamus, cerebellar vermis and upper ventral pons. There were no significant differences in activation between slow and fast contractions. Toe movements involved significantly stronger activity of the paracentral lobule (ie the medial primary motor cortex) than did the pelvic floor contractions. Otherwise the areas active during pelvic floor and leg muscle contractions overlapped considerably. The motor cortical representation of pelvic floor muscles is located mostly in the supplementary motor area. It extends further ventrally and anteriorly than the representation of distal leg muscles. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Puricelli, Edela; Barreiro, Bernardo Ottoni Braga; Quevedo, Alexandre Silva; Ponzoni, Deise
2017-01-01
Lesions in the floor of the mouth can be a challenging diagnosis due to the variety of pathological conditions that might be found in this area. Within a broad range of lesions, attention has to be addressed to those that require specific management, such as a dermoid cyst (DC) and a ranula. Especially in pediatric patients, in whom the failure of diagnosis can postpone the correct treatment and cause sequelae later in life. DC, a developmental anomaly, is managed primarily by surgical resection. On the other hand, ranula is a pseudocyst that may be treated by marsupialization. This article reports a large and painful lesion in the floor of the mouth in a pediatric patient. With a diagnostic hypothesis of ranula, two surgical interventions were performed, but there were recurrences of the lesion. Subsequently, the patient was referred to the Oral and Maxillofacial Surgery Unit for re-evaluation. Computed tomography showed a semi-transparent image suggesting a cystic formation. Another surgical procedure was performed where the lesion was completely removed. Anatomopathological analysis confirmed the diagnosis of DC. The five-year follow-up showed no signs of recurrence. This article indicates that although DC in the floor of the mouth is rare, it should be considered in the differential diagnosis of other diseases in this area. This precaution may be particularly important in the following circumstances: 1) Similar lesions that have different therapeutic approaches and, 2) To prevent future sequelae in pediatric patients.
NASA Astrophysics Data System (ADS)
Cárdenas, J.; Osma, G.; Caicedo, C.; Torres, A.; Sánchez, S.; Ordóñez, G.
2016-07-01
This research shows the energy analysis of the Electrical Engineering Building, located on campus of the Industrial University of Santander in Bucaramanga - Colombia. This building is a green pilot for analysing energy saving strategies such as solar pipes, green roof, daylighting, and automation, among others. Energy analysis was performed by means of DesignBuilder software from virtual model of the building. Several variables were analysed such as air temperature, relative humidity, air velocity, daylighting, and energy consumption. According to two criteria, thermal load and energy consumption, critical areas were defined. The calibration and validation process of the virtual model was done obtaining error below 5% in comparison with measured values. The simulations show that the average indoor temperature in the critical areas of the building was 27°C, whilst relative humidity reached values near to 70% per year. The most critical discomfort conditions were found in the area of the greatest concentration of people, which has an average annual temperature of 30°C. Solar pipes can increase 33% daylight levels into the areas located on the upper floors of the building. In the case of the green roofs, the simulated results show that these reduces of nearly 31% of the internal heat gains through the roof, as well as a decrease in energy consumption related to air conditioning of 5% for some areas on the fourth and fifth floor. The estimated energy consumption of the building was 69 283 kWh per year.
Oh, Hyeon-Ju; Jeong, Na-Na; Chi, Woo-Bae; Seo, Ji-Hoon; Jun, Si-Moon; Sohn, Jong-Ryeul
2015-10-01
Particulate matter (PM) in buildings are mostly sourced from the transport of outdoor particles through a heating, ventilation, and air conditioning (HVAC) system and generation of particle within the building itself. We investigated the concentrations and characteristic of indoor and outdoor particles and airborne bacteria concentrations across four floors of a building located in a high-traffic area. In all the floors we studied (first, second, fifth, and eighth), the average concentrations of particles less than 10 μm (PM10) in winter for were higher than those in summer. On average, a seasonal variation in the PM10 level was found for the first, fifth, and eighth floors, such that higher values occurred in the winter season, compared to the summer season. In addition, in winter, the indoor concentrations of PM10 on the first, fifth, and eighth floors were higher than those of the outdoor PM10. The maximum level of airborne bacteria concentration was found in a fifth floor office, which held a private academy school consisting of many students. Results indicated that the airborne bacteria remained at their highest concentration throughout the weekday period and varied by students' activity. The correlation coefficient (R (2)) and slope of linear approximation for the concentrations of particulate matter were used to evaluate the relationship between the indoor and outdoor particulate matter. These results can be used to predict both the indoor particle levels and the risk of personal exposure to airborne bacteria.
ETR, TRA642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTORGENERATOR ...
ETR, TRA-642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTOR-GENERATOR SETS AND OTHER ELECTRICAL EQUIPMENT. PHILLIPS PETROLEUM COMPANY ETR-D-1781, 7/1960. INL INDEX NO. 532-0642-00-706-020384, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2013 CFR
2013-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2014 CFR
2014-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2012 CFR
2012-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2011 CFR
2011-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
7 CFR Exhibit D to Subpart A of... - Thermal Performance Construction Standards
Code of Federal Regulations, 2010 CFR
2010-01-01
... floor insulation, the total heat loss attributed to the floor from the heated area shall not exceed the heat loss calculated for floors with required insulation. AInsulation may be omitted from floors over.... Definitions A. British thermal unit (Btu) means the quantity of heat required to raise the temperature of one...
Liao, Wenhua; Liu, Chunjing; Gao, Zhiling
2018-04-09
Patches of dung and urine are major contributors to the feedlot gas emissions. This study investigated the impacts of dung deposition frequency (partly reflecting animal stocking density of a feedlot), dairy feedlot floor conditions (old floor indicated with the presence of consolidated manure pad [CMP] vs. new floor with the absence of consolidated manure pad [CMPn]), and application of dicyandiamide (DCD) and hydroquinone (HQ) on nitrous oxide (N 2 O) and methane (CH 4 ) emissions from patches in the laboratory, and the integrative impacts were expressed in terms of global warming potential (CO 2 -equivalent). Dung deposition frequency, feedlot floor condition, and application of inhibitors showed inverse impacts on N 2 O and CH 4 emissions from patches. Greenhouse gas (GHG) emissions from the dung, urine, and dung+urine patches on the CMP feedlot surface were approximately 7.48, 87.35, and 7.10 times those on the CMPn feedlot surface (P < 0.05). Meanwhile, GHG emissions from CMP and CMPn feedlot surfaces under high deposition frequency condition were approximately 10 and 1.7 times those under low-frequency condition. Moreover, application of HQ slightly reduced the GHG emission from urine patches, by 14.9% (P > 0.05), while applying DCD or DCD+HQ significantly reduced the GHG, by 60.3% and 65.0%, respectively (P < 0.05). Overall, it is necessary to include feedlot management such as animal stocking density and feedlot floor condition to the process of determining emission factors for feedlots. In the future, field measurements to quantitatively evaluate the relative contribution of nitrification and denitrification to the N 2 O emissions of feedlot surfaces are highly required for effective N 2 O control. This study shows that feedlot CH 4 and N 2 O emissions inversely respond to the dicyandiamide (DCD) application. Applying DCD significantly reduces GHG emissions of feedlot urine patches. Feedlot floor condition and stocking density strongly impact feedlot GHG emissions. Including feedlot floor condition and stocking density in the feedlot EF determining process is necessary.
An argument for competency-based training in pelvic floor physiotherapy practice.
Frawley, Helena C; Neumann, Patricia; Delany, Clare
2018-05-10
Pelvic floor dysfunction has been described as "a silent epidemic," affecting many people in the community yet under-recognized and insufficiently managed. There is evidence that pelvic floor physiotherapy can manage many of these disorders, however a competency framework to guide and inform pelvic floor physiotherapy training and practice is lacking. The assessment and management of the pelvic floor complex is not addressed as a core component of most entry-to-practice physiotherapy programs despite being within the scope of physiotherapy practice which is in contrast with the knowledge and skills that physiotherapists graduate with in core areas of clinical practice. This results in a registration-competency gap, and the need for post-graduation training to ensure clinicians are appropriately skilled to practice safely and effectively in this area. In addition, there are potential ethical and legal issues unique to this area of physiotherapy practice to be considered. We use a series of clinical scenarios to highlight the domains of knowledge, skills and communication required for practice in this area, based on our experience in Australia. We propose a framework for the future which defines competence in pelvic floor physiotherapy to provide clarity to clinicians about their clinical, ethical and legal obligations to the public, our referrers and third-party payers.
A pilot study on the improvement of the lying area of finishing pigs by a soft lying mat.
Savary, Pascal; Gygax, Lorenz; Jungbluth, Thomas; Wechsler, Beat; Hauser, Rudolf
2011-01-01
In this pilot study, we tested whether a soft mat (foam covered with a heat-sealed thermoplastic) reduces alterations and injuries at the skin and the leg joints.The soft mat in the lying area of partly slatted pens was compared to a lying area consisting of either bare or slightly littered (100 g straw per pig and day) concrete flooring. In this study we focused on skin lesions on the legs of finishing pigs as indicators of impaired welfare. Pigs were kept in 19 groups of 8-10 individuals and were examined for skin lesions around the carpal and tarsal joints either at a weight of <35 kg, or at close to 100 kg. The likelihood of hairless patches and wounds at the tarsal joints was significantly lower in pens with the soft lying mat than in pens with a bare concrete floor. Pens with a littered concrete floor did not differ compared to pens with a bare concrete floor. The soft lying mat thus improved floor quality in the lying area in terms of preventing skin lesions compared to bare and slightly littered concrete flooring. Such soft lying mats have thus the potential to improve lying comfort and welfare of finishing pigs.
1974-08-01
COPY Reinforced concrete members ( beams and columns ): sizes, spans, support conditions, reinforcement ratios Steel members (open web joists, beams ...order of 30 to 50 percent of gross wall area are expected in upper portions butnt i n areas ’housing EOC’s. Open web joists and precast concrete units...are expected to dominate roof systems. Floors over the EOC’s are expected to be of rein- forced concrete . Cast-in-place flat plates and precast
Wang, Shousen; Qin, Yong; Xiao, Deyong; Wei, Liangfeng
2017-07-24
Endonasal transsphenoidal microsurgery is often adopted in the resection of pituitary adenoma, and has showed satisfactory treatment and minor injuries. It is important to accurately localize sellar floor and properly incise the bone and dura matter. Fifty-one patients with pituitary adenoma undergoing endonasal transsphenoidal microsurgery were included in the present study. To identify the scope of sellar floor opening, CT scan of the paranasal sinus and MRI scan of the pituitary gland were performed for each subject. Intraoperatively, internal carotid artery injury, leakage of cerebrospinal fluid, and tumor texture were recorded, and postoperative complications and residual tumors were identified. The relative size of sellar floor opening significantly differed among the pituitary micro-, macro- and giant adenoma groups, and between the total and partial tumor resection groups. The ratio of sellar floor opening area to maximal tumor area was significantly different between the total and partial resection groups. Logistic regression analysis revealed that the ratio of sellar floor opening area to the largest tumor area, tumor texture, tumor invasion and age were independent prognostic factors. The vertical distance between the top point of sellar floor opening and planum sphenoidale significantly differed between the patients with and without leakage of cerebrospinal fluid. These results together indicated that relatively insufficient sellar floor opening is a cause of leading to residual tumor, and the higher position of the opening and closer to the planum sphenoidale are likely to induce the occurrence of leakage of cerebrospinal fluid.
6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION ...
6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR
LOFT, TAN650. Service building preamp tower, top three floors. Floor ...
LOFT, TAN-650. Service building pre-amp tower, top three floors. Floor plan, cable mazes, duct labyrinth. Borated water tank enclosure on roof. Kaiser engineers 6413-11-STEP/LOFT-650-A-3. Date: October 1964. INEEL index code no. 036-650-00-486-122215 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Effect of different flooring systems on weight and pressure distribution on claws of dairy cows.
Telezhenko, E; Bergsten, C; Magnusson, M; Ventorp, M; Nilsson, C
2008-05-01
Weight and pressure distribution on the claw were studied in Swedish Holsteins housed in different flooring systems. A total of 127 cows housed in different sections of the experimental barn were used. Each section had different flooring in the walking and standing areas. There were rubber mats or abrasive mastic asphalt flooring on the alleys or a low-abrasive slatted concrete floor. Some sections had feed-stalls equipped with rubber mats; other sections did not. The vertical ground reaction force, contact area, and average contact pressure were determined on the left hind foot using the I-Scan system and analyzed with the F-scan system. These determinations were made in each of the following 3 zones of the claw: bulb, wall, and sole. Most of the weight on claws exposed to concrete floors was carried by the bulb (37.4 +/- 3.5 and 18.3 +/- 2.9% of weight exerted on the foot in the lateral and medial claw, respectively) and the wall zone (20.0 +/- 2.6 and 13.4 +/- 2.4% on lateral and medial claw, respectively). The weight and pressure distribution in cows kept on sections with rubber covered alleys but passing daily over the asphalt floor on their way to the milking parlor did not differ in any zones, except for lateral bulbs, compared with those exposed to slatted concrete alone. Still, the weight bearing of the sole zone in cows kept on rubber mats without access to asphalt was less than that of cows kept on concrete slatted floors (5.1 +/- 0.7 vs. 12.7 +/- 1.1% and 1.1 +/- 0.5 vs. 8.7 +/- 0.7% in lateral and medial claws, respectively). In cows kept on asphalt flooring without feed-stalls, most weight was exerted to the sole zone (36.2 +/- 2.9 and 22.2 +/- 1.8% in lateral and medial claws, respectively). Feed-stalls in combination with asphalt flooring yielded a decreased total contact area (30.1 +/- 1.2 cm(2)) compared with asphalt floors without feed-stalls (35.7 +/- 1.2 cm(2)). The largest total contact area was obtained on the asphalt floor without feed-stalls, resulting in a lower contact pressure (39.8 +/- 2.3 N/cm(2)) than in claws exposed to concrete (66.0 +/- 2.7 N/ cm(2)) or rubber mats (56.7 +/- 1.7 N/cm(2)). In conclusion, housing with abrasive floors resulted in claws with increased contact area at the sole surface and therefore, decreased contact pressure, but reduced the weight-bearing role of the strongest part of the claw capsule, the claw wall.
ERIC Educational Resources Information Center
Kennedy, Mike
2011-01-01
The day a school opens its doors for the first time, the flooring will be new and untarnished. When the flooring is in such pristine condition, many flooring materials--carpeting, vinyl, terrazzo, wood or some other surface--will look good. But school and university planners who decide what kind of material covers the floors of their facilities…
HOT CELL BUILDING, TRA632. FLOOR PLAN OF EXPANSION SHOWS LOCATION ...
HOT CELL BUILDING, TRA-632. FLOOR PLAN OF EXPANSION SHOWS LOCATION OF NEW CELLS, "HEAVY" CELL AT WEST END, "LIGHT" CELLS AT EAST. MOCK-UP AND STORAGE AREAS IN SOUTH HALF OF FLOOR. H.K. FERGUSON 895-MTR-ETR-632-A1, 12/1958. INL INDEX NO. 531-0632-00-279-101924, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
3. Eastlooking view of marine museum lower and upper floors ...
3. East-looking view of marine museum lower and upper floors from area office building window - Duluth Ship Canal, Marine Museum-Area Office, North end of Minnesota Point at Canal Park, Duluth, St. Louis County, MN
Hoaglund, J. R.; Kolak, J.J.; Long, D.T.; Larson, G.J.
2004-01-01
Two numerical models, one simulating present groundwater flow conditions and one simulating ice-induced hydraulic loading from the Port Huron ice advance, were used to characterize both modern and Pleistocene groundwater exchange between the Michigan Basin and near-surface water systems of Saginaw Bay (Lake Huron) and the surrounding Saginaw Lowlands area. These models were further used to constrain the origin of saline, isotopically light groundwater, and porewater from the study area. Output from the groundwater-flow model indicates that, at present conditions, head in the Marshall aquifer beneath Saginaw Bay exceeds the modern lake elevation by as much as 21 m. Despite this potential for flow, simulated groundwater discharge through the Saginaw Bay floor constitutes only 0.028 m3 s-1 (???1 cfs). Bedrock lithology appears to regulate the rate of groundwater discharge, as the portion of the Saginaw Bay floor underlain by the Michigan confining unit exhibits an order of magnitude lower flux than the portion underlain by the Saginaw aquifer. The calculated shoreline discharge of groundwater to Saginaw Bay is also relatively small (1.13 m3 s-1 or ???40 cfs) because of low gradients across the Saginaw Lowlands area and the low hydraulic conductivities of lodgement tills and glacial-lake clays surrounding the bay. In contrast to the present groundwater flow conditions, the Port Huron ice-induced hydraulic-loading model generates a groundwater-flow reversal that is localized to the region of a Pleistocene ice sheet and proglacial lake. This area of reversed vertical gradient is largely commensurate with the distribution of isotopically light groundwater presently found in the study area. Mixing scenarios, constrained by chloride concentrations and ??18O values in porewater samples, demonstrate that a mixing event involving subglacial recharge could have produced the groundwater chemistry currently observed in the Saginaw Lowlands area. The combination of models and mixing scenarios indicates that structural control is a major influence on both the present and Pleistocene flow systems.
ADM. Service Building (TAN603). Floor plan. Names of functional areas. ...
ADM. Service Building (TAN-603). Floor plan. Names of functional areas. Ralph M. Parsons 902-2-ANY-603-A 43. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 033-0603-00-693-106718 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterling, D.A.; Roegner, K.C.; Lewis, R.D.
Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less
DeepSurveyCam—A Deep Ocean Optical Mapping System
Kwasnitschka, Tom; Köser, Kevin; Sticklus, Jan; Rothenbeck, Marcel; Weiß, Tim; Wenzlaff, Emanuel; Schoening, Timm; Triebe, Lars; Steinführer, Anja; Devey, Colin; Greinert, Jens
2016-01-01
Underwater photogrammetry and in particular systematic visual surveys of the deep sea are by far less developed than similar techniques on land or in space. The main challenges are the rough conditions with extremely high pressure, the accessibility of target areas (container and ship deployment of robust sensors, then diving for hours to the ocean floor), and the limitations of localization technologies (no GPS). The absence of natural light complicates energy budget considerations for deep diving flash-equipped drones. Refraction effects influence geometric image formation considerations with respect to field of view and focus, while attenuation and scattering degrade the radiometric image quality and limit the effective visibility. As an improvement on the stated issues, we present an AUV-based optical system intended for autonomous visual mapping of large areas of the seafloor (square kilometers) in up to 6000 m water depth. We compare it to existing systems and discuss tradeoffs such as resolution vs. mapped area and show results from a recent deployment with 90,000 mapped square meters of deep ocean floor. PMID:26828495
INTERIOR SHOWING STAIRCASE TO SECOND FLOOR FROM MAIN LOBBY/RECEPTION AREA, ...
INTERIOR SHOWING STAIRCASE TO SECOND FLOOR FROM MAIN LOBBY/RECEPTION AREA, VIEW FACING WEST-SOUTHWEST. - Naval Air Station Barbers Point, Control Tower & Aviation Operations Building, Near intersection of runways between Hangar 110 & Building 115, Ewa, Honolulu County, HI
7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA ...
7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR
Drahota, Amy; Gal, Diane; Windsor, Julie; Dixon, Simon; Udell, Julie; Ward, Derek; Soilemezi, Dia; Dean, Taraneh; Severs, Martin
2011-12-01
Falls are an issue disproportionately affecting older people who are at increased risk of falls and injury. This protocol describes a pilot study investigating shock-absorbing flooring for fall-related injuries in wards for older people. To inform future research by evaluating fall-related injuries on the intervention and existing flooring, assessing the sustainability of the flooring in ward environments, estimating the cost-effectiveness of the floor and assessing how the floor affects patients and other users. This study uses mixed methods a pilot cluster randomised controlled trial, observation via mechanical testing and interviews. Eight participating wards (clusters) are randomised using a computer-generated list. No blinding is incorporated into the study. Each site has a baseline period of approximately 6 months. Then, four sites receive the intervention floor, while four continue using standard floors. Sites are then followed up for approximately 1 year. Any person admitted to a bed in the 'study area' of a participating ward can be entered into the trial. Orientated patients, visitors and any hospital staff who use the floor in a study area are eligible for inclusion in an interview. An 8.3 mm thick vinyl floor covering with polyvinyl chloride foam backing (Tarkett Omnisports EXCEL). The primary outcome is fall-related injuries. Severity of injuries, falls, cost-effectiveness, user views and mechanical performance (shock absorbency and slip resistance) are also being assessed.
A Summary--The Economics of Carpeting and Resilient Flooring. An Evaluation and Comparison.
ERIC Educational Resources Information Center
Parks, George M.
Of use to those concerned with the economics of flooring selection and maintenance, this comparison may prove useful as an estimating guide in the preparation of cost estimates for any flooring area where economics is a factor in the choice of materials. All costs attributed to carpet or resilient flooring have been obtained either by survey or…
Estimated flows of gases and carbon within CEEF ecosystem composed of human, crops and goats
NASA Astrophysics Data System (ADS)
Tako, Y.; Komatsubara, O.; Honda, G.; Arai, R.; Nitta, K.
The Closed Ecology Experiment Facilities (CEEF) can be used as a test bed for Controlled Ecological Life Support Systems (CELSS), because technologies developed for the CEEF system facilitate self-sufficient material circulation necessary for long term missions such as Lunar and Mars exploration. In the experiment conducted under closed condition in FY2003, rice and soybeans were cultivated sequentially in two chambers and a chamber, each having a cultivation area of 30 m2 and floor area of 43 m2, inside the Plantation Module with artificial lighting of the CEEF. In the chamber having a cultivation area of 60 m2 and floor area of 65 m2, inside the Plantation Module with natural and artificial lighting, peanuts and safflowers were also cultivated. Stable transplant (or seeding) and harvest of each crop were maintained during a month. Flows of CO2, O2 and carbon to and from the crops were analyzed during the stable cultivation period. Simulated works and stay in the CEEF lasting five days were conducted two times under ventilating condition in FY2003. Gas exchange of human was estimated using heart rate data collected during the experiments and correlation between gas exchange rate and heart rate. Gas exchange rate and carbon balance of female goats were determined using an open-flow measurement system with a gastight chamber. From these results, flows of gases and carbon in the CEEF were discussed.
Weather support area, floor plan and details. ("Alter COC, Bldg. ...
Weather support area, floor plan and details. ("Alter COC, Bldg. 2605, Weather Support Area, Floor Plan & Details" Also includes a site plan and a finish schedule. The exact location of this construction is obscure, but it appears to be the enclosure of space at the north end of room 101, the "Display Area" or "War Room") Strategic Air Command, Civil Engineering. Drawing no. B-1081, sheet no. 1 of 2, 9 July 1968; project no. MAR-132-8; CE-562; file drawer 2605-9, also 1315. Various scales. 29x41 inches. pencil on paper - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Sea-floor geology in northeastern Block Island Sound, Rhode Island
McMullen, Kate Y.; Poppe, Lawrence J.; Ackerman, Seth D.; Blackwood, Dann S.; Lewit, P.G.; Parker, Castle E.
2013-01-01
Multibeam-echosounder and sidescan-sonar data collected by the National Oceanic and Atmospheric Administration in northeastern Block Island Sound, combined with sediment samples and bottom photography collected by the U.S. Geological Survey, are used to interpret sea-floor features and sedimentary environments in this 52-square-kilometer-area offshore Rhode Island. Boulders, which are often overgrown with sessile fauna and flora, are mostly in water depths shallower than 20 meters. They are probably part of the southern flank of the Harbor Hill-Roanoke Point-Charlestown-Buzzards Bay moraine, deposited about 18,000 years ago. Scour depressions, areas of the sea floor with a coarser grained, rippled surface lying about 0.5 meter below the finer grained, surrounding sea floor, along with erosional outliers within the depressions are in a band near shore and also offshore in deep parts of the study area. Textural and bathymetric differences between areas of scour depressions and the surrounding sea floor or erosional outliers stand out in the sidescan-sonar imagery with sharp tonal contrasts. Also visible in the sidescan-sonar imagery are broad, low-profile bedforms with coarser grained troughs and finer grained crests.
29 CFR 1926.855 - Manual removal of floors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... floor arch, debris and other material shall be removed from such arch and other adjacent floor area... collapse. The open space between planks shall not exceed 16 inches. (c) Safe walkways, not less than 18... cleared of debris and any other unnecessary materials. ...
29 CFR 1926.855 - Manual removal of floors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... floor arch, debris and other material shall be removed from such arch and other adjacent floor area... collapse. The open space between planks shall not exceed 16 inches. (c) Safe walkways, not less than 18... cleared of debris and any other unnecessary materials. ...
29 CFR 1926.855 - Manual removal of floors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... floor arch, debris and other material shall be removed from such arch and other adjacent floor area... collapse. The open space between planks shall not exceed 16 inches. (c) Safe walkways, not less than 18... cleared of debris and any other unnecessary materials. ...
29 CFR 1926.855 - Manual removal of floors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... floor arch, debris and other material shall be removed from such arch and other adjacent floor area... collapse. The open space between planks shall not exceed 16 inches. (c) Safe walkways, not less than 18... cleared of debris and any other unnecessary materials. ...
29 CFR 1926.855 - Manual removal of floors.
Code of Federal Regulations, 2014 CFR
2014-07-01
... floor arch, debris and other material shall be removed from such arch and other adjacent floor area... collapse. The open space between planks shall not exceed 16 inches. (c) Safe walkways, not less than 18... cleared of debris and any other unnecessary materials. ...
36 CFR 910.33 - Off-street parking.
Code of Federal Regulations, 2011 CFR
2011-07-01
... not fixed, each seven square feet of gross floor area usable for seating shall be considered one seat; (3) Retail, trade, and service establishments: one parking space for each 750 square feet of gross... each 1,800 square feet of gross floor area. ...
36 CFR 910.33 - Off-street parking.
Code of Federal Regulations, 2010 CFR
2010-07-01
... not fixed, each seven square feet of gross floor area usable for seating shall be considered one seat; (3) Retail, trade, and service establishments: one parking space for each 750 square feet of gross... each 1,800 square feet of gross floor area. ...
36 CFR 910.33 - Off-street parking.
Code of Federal Regulations, 2014 CFR
2014-07-01
... not fixed, each seven square feet of gross floor area usable for seating shall be considered one seat; (3) Retail, trade, and service establishments: one parking space for each 750 square feet of gross... each 1,800 square feet of gross floor area. ...
36 CFR 910.33 - Off-street parking.
Code of Federal Regulations, 2012 CFR
2012-07-01
... not fixed, each seven square feet of gross floor area usable for seating shall be considered one seat; (3) Retail, trade, and service establishments: one parking space for each 750 square feet of gross... each 1,800 square feet of gross floor area. ...
A study of riders' noise exposure on Bay Area Rapid Transit trains.
Dinno, Alexis; Powell, Cynthia; King, Margaret Mary
2011-02-01
Excessive noise exposure may present a hazard to hearing, cardiovascular, and psychosomatic health. Mass transit systems, such as the Bay Area Rapid Transit (BART) system, are potential sources of excessive noise. The purpose of this study was to characterize transit noise and riders' exposure to noise on the BART system using three dosimetry metrics. We made 268 dosimetry measurements on a convenience sample of 51 line segments. Dosimetry measures were modeled using linear and nonlinear multiple regression as functions of average velocity, tunnel enclosure, flooring, and wet weather conditions and presented visually on a map of the BART system. This study provides evidence of levels of hazardous levels of noise exposure in all three dosimetry metrics. L(eq) and L(max) measures indicate exposures well above ranges associated with increased cardiovascular and psychosomatic health risks in the published literature. L(peak) indicate acute exposures hazardous to adult hearing on about 1% of line segment rides and acute exposures hazardous to child hearing on about 2% of such rides. The noise to which passengers are exposed may be due to train-specific conditions (velocity and flooring), but also to rail conditions (velocity and tunnels). These findings may point at possible remediation (revised speed limits on longer segments and those segments enclosed by tunnels). The findings also suggest that specific rail segments could be improved for noise.
40 CFR 435.11 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (dd) Sanitary waste means the human body waste discharged from toilets and urinals located within...: (i) Water area as used in “site” in 40 CFR 122.29 and 122.2 means the water area and water body floor... 122.29 means the process of surveying, clearing or preparing an area of the water body floor for the...
24 CFR 3285.505 - Crawlspace ventilation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of ventilation openings must not be less than one square foot (ft.2) for every 150 square feet (ft.2) of the home's floor area. The total area of ventilation openings may be reduced to one square foot (ft.2) for every 1,500 square feet (ft.2) of the home's floor area, where a uniform 6-mil polyethylene...
24 CFR 3285.505 - Crawlspace ventilation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of ventilation openings must not be less than one square foot (ft.2) for every 150 square feet (ft.2) of the home's floor area. The total area of ventilation openings may be reduced to one square foot (ft.2) for every 1,500 square feet (ft.2) of the home's floor area, where a uniform 6-mil polyethylene...
24 CFR 3285.505 - Crawlspace ventilation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of ventilation openings must not be less than one square foot (ft.2) for every 150 square feet (ft.2) of the home's floor area. The total area of ventilation openings may be reduced to one square foot (ft.2) for every 1,500 square feet (ft.2) of the home's floor area, where a uniform 6-mil polyethylene...
24 CFR 3285.505 - Crawlspace ventilation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of ventilation openings must not be less than one square foot (ft.2) for every 150 square feet (ft.2) of the home's floor area. The total area of ventilation openings may be reduced to one square foot (ft.2) for every 1,500 square feet (ft.2) of the home's floor area, where a uniform 6-mil polyethylene...
J. A. Parrotta; O. H. Knowles; J.M. Wunderle Jr.
1997-01-01
Patterns of plant and animal diversity were studied in a 10-year-old native species reforestation area at a bauxite-mined site at porto Trombetas in western Para State, Brazil. Understorey and overstorey floristic composition and structure, understorey light conditions, forest floor development and soil properties were evaluated in a total of 38 78.5-m2
LOFT. Containment and service building (TAN650) ground floor plan. Penetrations ...
LOFT. Containment and service building (TAN-650) ground floor plan. Penetrations in dome wall. Shielded personnel maze at airlock door. Reactor chamber floor hatches and holddowns. Rails in concrete floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-2. Date: October 1964. INEEL index code no. 036-650-00-486-122214 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF Reactor Building (PER620). Floor at left of view is ...
PBF Reactor Building (PER-620). Floor at left of view is floor of first basement. Photographer: Farmer/Capek. Date: March 17, 1967. INEEL negative no. 67-1753 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Johnny L. Boggs; Steven G. McNulty; Linda H. Pardo
2007-01-01
We evaluated foliar and forest floor chemistry across a gradient of N deposition in the Northeast at 11 red spruce (Picea rubens Sarg.) sites in 1987/1988 and foliar and forest floor chemistry and basal area growth at six paired spruce and deciduous sites in 1999. The six red spruce plots were a subset of the original 1987/1988 spruce sites. In 1999...
Hardwood? Carpet? or Tile? A comparison of flooring costs under residential conditions
David G. Martens; David G. Martens
1971-01-01
Initial installation cost, annual maintenance cost, and total long-term cost are important in the purchase of flooring products. Before deciding on a flooring material, the prudent buyer will consider each of these in relation to his personal desires. From these evaluations, he will then be able to select the flooring material that is best suited to his individual...
ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP640). ...
ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111678. ALTERNATE ID NUMBER 8952-CPP-640-A-1. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
44. GLAZE STORAGE AND MIXING AREA, GROUND FLOOR, EAST WING. ...
44. GLAZE STORAGE AND MIXING AREA, GROUND FLOOR, EAST WING. TILES ARE DIPPED IN GLAZE AT THE COUNTER AGAINST THE FAR WALL. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA
Keleş, A; Keskin, C
2018-02-01
To conduct a quantitative and qualitative analysis of the band-shaped isthmus area, the floor of which was in the apical third in the mesial roots of mandibular first molars using micro-computed tomography (micro-CT). Micro-CT images of 269 mesial roots of mandibular first molars were evaluated, and 40 specimens with a band-shaped isthmus, with a floor in the apical third, were selected. The major diameter, minor diameter, roundness, area and perimeter values for the most coronal and apical slices where the isthmus was visible were measured. The distances between these slices were measured as the isthmus length, and the total volume, structure model index and surface area of the isthmus were measured. The distances between the isthmus floor and two apical foramina and the number of root canal orifices were calculated. The dimensions of the isthmus roof and the floor were compared, and the data were analysed using descriptive statistics and Student's t-tests with a significance threshold set at 5%. A total of 15% of the specimens had band-shaped isthmuses with a floor in the apical third. The isthmus roof exhibited significantly greater major and minor diameter values compared to the isthmus floor (P < 0.05). No significant difference was detected between the isthmus roof and the floor with regard to roundness (P > 0.05). Three- and two-dimensional analyses of the mesial roots of mandibular molars revealed that band-shaped isthmuses had complex shapes. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Sea-floor geology in northwestern Block Island Sound, Rhode Island
McMullen, Katherine Y.; Poppe, Lawrence J.; Ackerman, Seth D.; Blackwood, Dann S.; Woods, D.A.
2014-01-01
Multibeam-echosounder and sidescan-sonar data, collected by the National Oceanic and Atmospheric Administration in a 69-square-kilometer area of northwestern Block Island Sound, are used with sediment samples, and still and video photography of the sea floor, collected by the U.S. Geological Survey at 43 stations within this area, to interpret the sea-floor features and sedimentary environments. Features on the sea floor include boulders, sand waves, scour depressions, modern marine sediments, and trawl marks. Boulders, which are often several meters wide, are found in patches in the shallower depths and tend to be overgrown with sessile flora and fauna. They are lag deposits of winnowed glacial drift, and reflect high-energy environments characterized by processes associated with erosion and nondeposition. Sand waves and megaripples tend to have crests that either trend parallel to shore with 20- to 50-meter (m) wavelengths or trend perpendicular to shore with several-hundred-meter wavelengths. The sand waves reflect sediment transport directions perpendicular to shore by waves, and parallel to shore by tidal or wind-driven currents, respectively. Scour depressions, which are about 0.5 m lower than the surrounding sea floor, have floors of gravel and coarser sand than bounding modern marine sediments. These scour depressions, which are conspicuous in the sidescan-sonar data because of their more highly reflective coarser sediment floors, are likely formed by storm-generated, seaward-flowing currents and maintained by the turbulence in bottom currents caused by their coarse sediments. Areas of the sea floor with modern marine sediments tend to be relatively flat to current-rippled and sandy.
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID ...
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID NOT EXPLAIN DARK CLOUD. MTR WING WILL ATTACH TO GROUND FLOOR. INL NEGATIVE NO. 1567. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Li, Bo; Ling, Zongcheng; Zhang, Jiang; Chen, Jian; Liu, ChangQing; Bi, Xiangyu
2018-02-01
Highland crater Lalande (4.45°S, 8.63°W; D = 23.4 km) is located on the PKT area of the lunar near side, southeast of the Mare Insularum. It is a complex crater in Copernican era and has three distinguishing features: high silicic anomaly, the highest Th abundance and special landforms on its floor. There are some low-relief bulges on the left of Lalande's floor with regular circle or ellipse shapes. They are ∼250-680 m wide and ∼30-91 m high with maximum flank slopes >20°. There are two possible scenarios for the formation of these low-relief bulges which are impact melt products or young silicic volcanic eruptions. We estimated the absolute model ages of the ejecta deposits, several melt ponds and the hummocky floor and determined the ratio of diameter and depth of the crater Lalande. In addition, we found some similar bugle features within other Copernican-aged craters and there were no volcanic source vents on Lalande's floor. Thus, we hypothesized that these low-relief bulges were most consistent with an origin of impact melts during the crater formation instead of small and young volcanic activities occurring on the floor. Based on Kaguya Terrain Camera (TC) ortho-mosaic and Digital Terrain Model (DTM) data produced by TC imagery in stereo, geological units and some linear features on the floor and wall of Lalande have been mapped. Eight geological units are organized by crater floor units: hummocky floor, central peak and low-relief bulges; and crater wall units: terraced walls, channeled and veneered walls, interior walls, mass wasting areas, blocky areas, and melt ponds. These geological units and linear features provided us a chance to understand some details of the cratering process and elevation differences on the floor. We proposed that subsidence due to melt cooling, late-stage wall collapse and rocks uplifted from beneath the surface could be the possible causes of the observed elevation differences on Lalande's floor.
Views of the Sea Floor in Northern Monterey Bay, California
Storlazzi, Curt D.; Golden, Nadine E.; Finlayson, David P.
2008-01-01
A sonar survey that produced unprecedented high-resolution images of the sea floor in northern Monterey Bay was conducted in 2005 and 2006. The survey, performed over 14 days by the U.S. Geological Survey (USGS), consisted of 172 tracklines and over 300 million soundings and covered an area of 12.2 km2 (4.7 mi2). The goals of this survey were to collect high-resolution bathymetry (depth to the sea floor) and acoustic backscatter data (amount of sound energy bounced back from the sea floor, which provides information on sea-floor hardness and texture) from the inner continental shelf. These data will provide a baseline for future change analyses, geologic mapping, sediment- and contaminant-transport studies, benthic-habitat delineation, and numerical modeling efforts. The survey shows that the inner shelf in this area is extremely varied in nature, encompassing flat sandy areas, faults, boulder fields, and complex bedrock ridges that support rich marine ecosystems. Furthermore, many of these complex bedrock ridges form the ?reefs? that result in a number of California?s classic surf breaks.
D'Souza, Clive; Paquet, Victor L; Lenker, James A; Steinfeld, Edward
2017-11-13
Low ridership of public transit buses among wheeled mobility device users suggests the need to identify vehicle design conditions that are either particularly accommodating or challenging. The objective of this study was to determine the effects of low-floor bus interior seating configuration and passenger load on wheeled mobility device user-reported difficulty, overall acceptability and design preference. Forty-eight wheeled mobility users evaluated three interior design layouts at two levels of passenger load (high vs. low) after simulating boarding and disembarking tasks on a static full-scale low-floor bus mockup. User self-reports of task difficulty, acceptability and design preference were analyzed across the different test conditions. Ramp ascent was the most difficult task for manual wheelchair users relative to other tasks. The most difficult tasks for users of power wheelchairs and scooters were related to interior circulation, including moving to the securement area, entry and positioning in the securement area and exiting the securement area. Boarding and disembarking at the rear doorway was significantly more acceptable and preferred compared to the layouts with front doorways. Understanding transit usability barriers, perceptions and preferences among wheeled mobility users is an important consideration for clinicians who recommend mobility-related device interventions to those who use public transportation. Implications for Rehabilitation In order to maximize community participation opportunities for wheeled mobility users, clinicians should consider potential public transit barriers during the processes of wheelchair device selection and skills training. Usability barriers experienced by wheeled mobility device users on transit vehicles differ by mobility device type and vehicle configurations. Full-scale environment simulations are an effective means of identifying usability barriers and design needs in people with mobility impairments and may provide an alternative model for determining readiness for using fixed route buses or eligibility for paratransit.
2010-07-01
Edgemeade Readiness Center are public lands managed by the BLM. These areas are primarily composed of undeveloped basalt plains dominated by 4.0 Affected...areas where new buildings would be constructed. 4.10.2 Existing Conditions Basaltic formations in the general vicinity are in abundance. The Snake...River has cut down through many of these formations leaving basalt plains and terraces several hundred feet above the valley floor. Subsequently
ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT ...
ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111679. ALTERNATE ID NUMBER 8952-CPP-640-A-2. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
40 CFR 435.41 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... separation even if located separately from wellheads. (dd) Sanitary waste means the human body waste... means the water area and water body floor beneath any exploratory, development, or production facility... preparing an area of the water body floor for the purpose of constructing or placing a development or...
36 CFR 910.60 - Gross floor area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Gross floor area. 910.60 Section 910.60 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE...
36 CFR 910.60 - Gross floor area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Gross floor area. 910.60 Section 910.60 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT CORPORATION GENERAL GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE...
VIEW OF PDP ROOM WITH FLOOR AT LEVEL +15 AND ...
VIEW OF PDP ROOM WITH FLOOR AT LEVEL +15 AND SHEAVE RACK ABOVE, LOOKING SOUTH. ON THE LEFT SIDE, CABLES GO THROUGH THE WALL TOWARD THE PDP CONTROL ROOM AREA - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC
35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING ...
35. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" DINING AREA LOOKING WEST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT
148. ARAIII Reactor building (ARA608) Floor plan. Shows location of ...
148. ARA-III Reactor building (ARA-608) Floor plan. Shows location of reactor, heater, and mechanical loop pits; mechanical and electrical equipment rooms; and other work areas. Aerojet-general 880-area/GCRE-608-A-1. Date: February 1958. Ineel index code no. 063-0608-00-013-102612. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
A&M. TAN607 second floor plan for cold assembly area. Metallurgical ...
A&M. TAN-607 second floor plan for cold assembly area. Metallurgical lab, chemistry lab, nuclear instrument lab, equipment rooms. Ralph M. Parsons 902-ANP-607-A 102. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-693-106754 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
20. MAIN FLOOR CANNING AREA LOOKING SOUTH Stairway to ...
20. MAIN FLOOR CANNING AREA - LOOKING SOUTH Stairway to the left leads into empty can storage area from which a can conveyor track, for flat oval cans, can be seen descending at a forty-five degree angle. Cement bases in the foreground held brining tanks into which cut fish were sluiced. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA
ASBESTOS EXPOSURES DURING ROUTINE FLOOR TILE MAINTENANCE. PART 1: SPRAY-BUFFING AND WET-STRIPPING
This study was conducted to ealuate airborne asbestos concentrations during spray-uffing and wet-stripping of asbestos-containing residient floor tile under three levels of floor conditions (poor, medium, and good). Airborne asbestos concentrations were measured by transmission e...
11. Second Floor of c. 1900 side ell addition. View ...
11. Second Floor of c. 1900 side ell addition. View looking from the rear of the automobile storage area toward the south front and east side corner and showing the ramp leading to the first floor. - Vaughn Chevrolet Building, 101-109 East Main Street, Monongahela, Washington County, PA
Gunnarsson, S; Keeling, L J; Svedberg, J
1999-03-01
1. Effects of rearing conditions on behavioural problems were investigated in a cohort study of commercial flocks of laying hens housed in 2 different loose housing systems. The sample population was 120 385 laying hens from 59 flocks of various hybrids at 21 different farms. 2. Logistic regression modelling was used to test the effects of selected factors on floor eggs, cloacal cannibalism and feather pecking. In addition to early access to perches or litter, models included hybrid, stocking density, group size, housing system, age at delivery, identical housing system at the rearing farm and at the production farm and, in models for floor eggs and cloacal cannibalism, nest area per hen. Odds ratios were calculated from the results of the models to allow risk assessment. 3. No significant correlations were found between the prevalence of floor eggs, cloacal cannibalism and feather pecking. 4. Access to perches from not later than the 4th week of age decreased the prevalence of floor eggs during the period from start-of-lay until 35 weeks of age, odds ratio 0-30 (P<0-001). Furthermore, early access to perches decreased the prevalence of cloacal cannibalism during the production period, odds ratio 0-46 (P=0.03). 5. No other factor had a significant effect in these models. Although it was not significant, early access to litter had a non-significant tendency to reduce the prevalence of feather pecking.
24 CFR 3280.109 - Room requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Planning Considerations § 3280.109 Room requirements. (a) Every manufactured home shall have at least one living area with not less than 150 sq. ft. of gross floor area. (b) Rooms designed for sleeping purposes shall have a minimum gross square foot floor...
21. DETAIL OF AREA WHERE FIRST FLOOR PASSAGEWAY USED TO ...
21. DETAIL OF AREA WHERE FIRST FLOOR PASSAGEWAY USED TO BE SHOWING VERTICAL WOOD MOLDING COVERING JOINT WHERE PARTITION USED TO BE (LEFT), TELLER'S WINDOW LINKING PASSAGEWAY WITH INFORMATION BOOTH (CENTER), AND TYPICAL FURNITURE. VIEW TO EAST. - Boise Project, Boise Project Office, 214 Broadway, Boise, Ada County, ID
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605, INTERIOR. FIRST FLOOR. CAMERA IS IN ...
PROCESS WATER BUILDING, TRA-605, INTERIOR. FIRST FLOOR. CAMERA IS IN SOUTHEAST CORNER AND FACES NORTHWEST. CONTROL ROOM AT RIGHT. CRANE MONORAIL IS OVER FLOOR HATCHES AND FLOOR OPENINGS. SIX VALVE HANDWHEELS ALONG FAR WALL IN LEFT CENTER VIEW. SEAL TANK IS ON OTHER SIDE OF WALL; PROCESS WATER PIPES ARE BELOW VALVE WHEELS. NOTE CURBS AROUND FLOOR OPENINGS. INL NEGATIVE NO. HD46-26-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Kanter, Gregg; Rogers, Rebecca G; Pauls, Rachel N; Kammerer-Doak, Dorothy; Thakar, Ranee
2015-01-01
Introduction and Hypothesis We evaluated the associations between pelvic floor muscle strength and tone with sexual activity and sexual function in women with pelvic floor disorders. Methods This was a secondary analysis of a multicenter study of women with pelvic floor disorders from the US and UK performed to validate the Pelvic Organ Prolapse/Incontinence Sexual Questionnaire, IUGA-Revised (PISQ-IR). Participants were surveyed about whether they were sexually active and completed the PISQ-IR and Female Sexual Function Index (FSFI) questionnaires to assess sexual function. Physical exams included assessment of pelvic floor strength by the Oxford Grading Scale, and assessment of pelvic floor tone per ICS guidelines. Results The cohort of 585 women was middle aged (mean age 54.9 +/−12.1) with 395 (67.5%) reporting sexual activity. Women with a strong pelvic floor (n=275) were more likely to report sexual activity than women with weak strength (n=280) (75.3 vs. 61.8%, p<0.001), but normal or hypoactive pelvic floor tone was not associated with sexual activity (68.8 vs. 60.2%, normal vs. hypoactive, p=0.08). After multivariable analysis, a strong pelvic floor remained predictive of sexual activity (OR 1.89, CI 1.18–3.03, p<0.01). Among sexually active women (n=370), a strong pelvic floor was associated with higher scores on the PISQ-IR domain of condition impact (Parameter Estimate 0.20+/−0.09, P=0.04), and FSFI orgasm domain (PE 0.51+/−0.17, P=0.004). Conclusion A strong pelvic floor is associated with higher rates of sexual activity as well as higher sexual function scores on the condition impact domain of the PISQ-IR and orgasm domain of the FSFI. PMID:25994625
NASA Astrophysics Data System (ADS)
Fan, L. F.; Lien, K. L.; Hsieh, I. C.; Lin, S.
2017-12-01
Methane seep in deep sea environment could lead to build up of chemosynthesis communities, and a number of geological and biological anomalies as compare to the surrounding area. In order to examine the linkage between seep anomalies and those at the vicinity background area, and to detail mapping those spatial variations, we used a deep towed camera system (TowCam) to survey seafloor on the Tainan Ridge, Northeastern South China Sea (SCS). The underwater sea floor pictures could provide better spatial variations to demonstrate impact of methane seep on the sea floor. Water column variations of salinity, temperature, dissolved oxygen were applied to delineate fine scale variations at the study area. In addition, sediment cores were collected for chemical analyses to confirm the existence of local spatial variations. Our results show large spatial variations existed as a result of differences in methane flux. In fact, methane is the driving force for the observed biogeochemical variations in the water column, on the sea floor, and in the sediment. Of the area we have surveyed, there are approximately 7% of total towcam survey data showing abnormal water properties. Corresponding to the water column anomalies, underwater sea floor pictures taken from those places showed that chemosynthetic clams and muscles could be identified, together with authigenic carbonate buildups, and bacterial mats. Moreover, sediment cores with chemical anomalies also matched those in the water column and on the sea floor. These anomalies, however, represent only a small portion of the area surveyed and could not be identified with typical (random) coring method. Methane seep, therefore, require tedious and multiple types of surveys to better understand the scale and magnitude of seep and biogeochemical anomalies those were driven by gas migrations.
143. ARAIII Control building (ARA607) Floor plan. Shows control room, ...
143. ARA-III Control building (ARA-607) Floor plan. Shows control room, contaminated work area, counting and computer room, health physics room, instrument repair room, offices, and other rooms. Aerojet-general 880-area/GCRE-607-A-1. Date: February 1958. Ineel index code no. 063-0607-00-013-102546. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
SPERTI Gate House at control area (PER603). Floor plan, elevations, ...
SPERT-I Gate House at control area (PER-603). Floor plan, elevations, sections. This Gate House replaced the original gate house, for which drawings are no longer extant. F.C. Torkelson 842-SPERT-603-A-1. Date: February 1962. INEEL index no. 760-0603-00-851-151336 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
19. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, FROM ...
19. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, FROM THE FEMALE MEDIUM SECURITY AREA FACING THE FEMALE MEDIUM SECURITY SLEEPING AREA. THE FEMALE CELL BLOCK DOOR IN SHOWN ON THE RIGHT OF PHOTO. THE SLEEPING AREA IS IN THE CENTER OF PHOTO. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI
Effect of Different Flooring Designs on the Performance and Foot Pad Health in Broilers and Turkeys.
Chuppava, Bussarakam; Visscher, Christian; Kamphues, Josef
2018-05-03
Litter quality has a significant influence on the performance and foot pad health in poultry. The objective of this study was to evaluate the effects of different types of flooring designs on the performance and foot pad health in fattening broilers and turkeys. Three trials were conducted for each species using a total of 720 Ross 308 broilers and 720 Big 6 turkeys. After day seven, animals were randomly assigned to four groups with three subgroups each: G1—floor pens with litter, G2—floor pens with litter and floor heating, G3—partially-slatted flooring, including a littered area, and G4—fully-slatted flooring with a sand bath (900 cm²). Animals of both species had a significantly higher final body weight at dissection (day 36) after being reared on fully-slatted floors compared to common littered floors. In turkeys, the feed conversion ratio was worse in G4 (1.53 ± 0.04) than in G1 (1.47 ± 0.02) and G2 (1.48 ± 0.03). Water to feed ratio was significantly higher in G2 than other groups. Turkeys’ foot pad health was significantly better in G4 than in other groups beginning at day 21. In turkeys, platforms with slatted floors that allow for temporary separation of the feet from the litter could lead to improvements in foot pad health which could better enable the realization of species-specific behaviours and activities in littered areas.
This study was conducted to evaluate airborne asbestos concentrations during ultra high speed (UHS) burnishing and wet-stripping of asbestos-containing resilient floor tile under two levels of floor care condition (poor and good). Airborne asbestos concentrations were measured by...
49 CFR 38.23 - Mobility aid accessibility.
Code of Federal Regulations, 2012 CFR
2012-10-01
... in width. When the platform is at vehicle floor height with the inner barrier (if applicable) down or... accessible entrance as practicable and shall have a clear floor area of 30 inches by 48 inches. Such space shall adjoin, and may overlap, an access path. Not more than 6 inches of the required clear floor space...
49 CFR 38.23 - Mobility aid accessibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... in width. When the platform is at vehicle floor height with the inner barrier (if applicable) down or... accessible entrance as practicable and shall have a clear floor area of 30 inches by 48 inches. Such space shall adjoin, and may overlap, an access path. Not more than 6 inches of the required clear floor space...
GROUND FLOOR OF JENNE BARN LOOKING EAST. (The barns ground ...
GROUND FLOOR OF JENNE BARN LOOKING EAST. (The barns ground floor is used for animal pens. On the left is an area enclosed for chickens. The Jenne milking stanchions remain along the south end of the barn.) - Jenne Farm, Barn, 538 Engle Road, Coupeville, Island County, WA
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR ...
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR UNDER WEATHER SHELTER DURING COLD WINTER. NOTE ABUNDANCE OF BEAMS; THE FLOOR WILL SUPPORT HEAVY LOADS. INL NEGATIVE NO. 1175. Unknown Photographer, 12/20/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Parker, E. Martin
Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new homemore » floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.« less
Thermal Analysis for Ion-Exchange Column System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Si Y.; King, William D.
2012-12-20
Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models weremore » used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.« less
Surficial geology of the sea floor in Long Island Sound offshore of Orient Point, New York
McMullen, K.Y.; Poppe, L.J.; Danforth, W.W.; Blackwood, D.S.; Schaer, J.D.; Guberski, M.R.; Wood, D.A.; Doran, E.F.
2011-01-01
The U.S. Geological Survey (USGS), the National Oceanic and Atmospheric Administration (NOAA), and the Connecticut Department of Environmental Protection (CT DEP) are working cooperatively to map and interpret features of the sea floor along the northeastern coast of the United States. This report presents multibeam bathymetry and sidescan-sonar data obtained during NOAA survey H11446, which was conducted in a 12-km2 area in Long Island Sound offshore of Orient Point, NY. In addition, sediment and photographic data from 26 stations obtained during a USGS verification cruise are presented. Overall, the sea floor slopes gently seaward, but topography is more complex in sand-wave and boulder areas, which are evident in the multibeam and sidescan-sonar data from the study area. Sand waves generally have north-south-oriented crests with 10- to 20-m wavelengths. Sand-wave asymmetry indicates eastward net sediment transport in the east and westward net sediment transport in the northern and western parts of the study area. Areas with boulders on the sea floor are typically hummocky and are part of a glacial moraine system. Boulders are typically encrusted with seaweed, sponges, and anemones as shown in the bottom photography.
117. ARAI Shop and maintenance (ARA627) building roof and floor ...
117. ARA-I Shop and maintenance (ARA-627) building roof and floor plan. Includes room finish and equipment schedule. Norman Engineering Company 961-area/SF-627-A-1. Date: January 1959. Ineel index code no. 068-0627-00-613-102759. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
24. View of lobby area on first floor transmitter building ...
24. View of lobby area on first floor transmitter building no. 102 looking into controlled access corridor and door system - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
LOFT. Containment and service building (TAN650) basement floor plan. Basement ...
LOFT. Containment and service building (TAN-650) basement floor plan. Basement airlock, shielded roadway, service areas, connection to control building. Kaiser engineers 6413-11-STEP/LOFT-650-A-1. Date: October 1964. INEEL index code no. 036-650-00-416-122213 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
160. ARAIII Service building (ARA610). Includes floor plan, north and ...
160. ARA-III Service building (ARA-610). Includes floor plan, north and west elevations, and section details. Aerojet-general 880-area/GCRE-610-A-1. Date: February 1958. Ineel index code no. 063-0610-00-013-102684. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR ...
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR PLAN AND VICINITY PLAN RELATIONSHIP TO ADMINISTRATION AND MAINTENANCE AREA. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-2. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
Structure-borne sound from magnetic resonance imaging systems
NASA Astrophysics Data System (ADS)
Ungar, Eric E.; Zapfe, Jeffrey A.
2003-10-01
Magnetic resonance imaging (MRI) systems are known to produce a considerable amount of audible noise. The recent tendency to install such systems on above-grade floors has led to increasing concerns about structure-borne noise transmission from the MRI to adjacent occupied areas. This paper presents the results of a study in which structure-borne noise forces produced by two operational MRI systems were determined via measurement of the floor vibrations induced by the systems and of the impedance of their supporting floors. Forces with known spectra were applied to the floors of planned MRI suites in a hospital extension and the corresponding noise in adjacent areas was measured. Similarly, airborne noise was introduced in the planned suites and the related noise in adjacent areas was measured. The results then were scaled to correspond to the measured MRI forces and airborne noise. It was found that in areas below the planned MRI installations structure-borne noise would predominate, unless it is mitigated. Structure-borne noise isolation of MRI systems, whose environments must meet stringent vibration criteria, is discussed briefly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burr, G.A.; Alderfer, R.J.
In response to a request from the Ohio Department of Health, an investigation was undertaken of possible hazardous working conditions at One Government Center, a modern 22 story municipal office building located in downtown Toledo, Ohio. Employees reported fatigue, nausea, headache, and other effects perhaps linked to poor indoor air quality. The building housed offices for the city of Toledo, the county and the state of Ohio. Questionnaires were administered to workers, and air quality measurements were made on floors 15 through 22. For the most part the concentration of carbon-dioxide (124389) was below the acceptable limit (1000 parts permore » million) with two exceptions which probably reflected a higher occupancy level and more extensive use of office partitions. Temperature and humidity levels measured were all within the acceptable limits. Respirable particulate levels in a smoking lounge located on the seventeenth floor were 454 micrograms/cubic meter and exceeded the recommended limit of 150 micrograms/cubic meter. The authors conclude that the indoor air quality parameters were within acceptable limits in most of the areas. The authors recommend that the existing smoking policy should be modified, and that the number of employees in specific areas be reduced or the ventilation in these same areas should be increased.« less
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), SECOND FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), SECOND FLOOR SHOWING PROCESS MAKEUP AREA AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING COLD LAB, DECONTAMINATION ROOM, MULTICURIE CELL ROOM, AND OFFICES. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051980. ALTERNATE ID NUMBER CPP-E-1980. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Lau, Winifred Ka Yan; Liang, Peng; Man, Yu Bon; Chung, Shan Shan; Wong, Ming Hung
2014-03-01
This study investigated health risks exerted on electronic waste (e-waste) recycling workers exposed to cadmium (Cd), chromium (Cr), copper (Cu), lead (Pb), nickel (Ni), mercury (Hg), and zinc (Zn) in Hong Kong. E-waste recycling workshops were classified into eight working areas: 1 = office, 2 = repair, 3 = dismantling, 4 = storage, 5 = desoldering, 6 = loading, 7 = cable shredding, and 8 = chemical waste. The aforementioned metal concentrations were analyzed in suspended air particulates, surface dust and floor dust collected from the above study areas in five workshops. Elevated Pb levels were measured in dismantling and desoldering areas (582 and 486 μg/100 cm(2) in surface and 3,610 and 19,172 mg/kg in floor dust, respectively). Blood lead levels of 10 and 39.5 μg/dl were estimated using United States Environmental Protection Agency's Adult Lead Model as a result of exposure to the floor dust from these two areas. Human health risk assessments were conducted to evaluate cancer and noncancer risks resulting from exposure to floor dust through the combined pathways of ingestion, dermal contact, and inhalation. Findings indicated that workers may be exposed to cancer risks above the acceptable range at 147 in a million at the 95th percentile in the dismantling area. Workers should be informed of associated risks to safeguard their health.
McMullen, Katherine Y.; Poppe, Lawrence J.; Danforth, William W.; Blackwood, Dann S.; Clos, Andrew R.; Parker, Castle E.
2014-01-01
Multibeam-echosounder data, collected during survey H12299 by the National Oceanic and Atmospheric Administration in a 162-square-kilometer area of Block Island Sound, northeast of Gardiners Island, New York, are used along with sediment samples and bottom photography, collected at 37 stations in this area by the U.S. Geological Survey during cruise 2013-005-FA, to interpret sea-floor features and sedimentary environments. These data and interpretations provide important base maps for future studies of the sea floor, focused, for example, on benthic ecology and resource management. The features and sedimentary environments on the sea floor are products of the glacial history and modern tidal regime. Features include bedforms such as sand waves and megaripples, boulders, a large current-scoured depression, exposed glaciolacustrine sediments, and areas of modern marine sediment. Sand covers much of the study area and is often in the form of sand waves and megaripples, which indicate environments characterized by coarse-grained bedload transport. Boulders and gravelly lag deposits, which indicate environments of erosion or nondeposition, are found off the coast of Gardiners Island and on bathymetric highs, probably marking areas where deposits associated with recessional ice-front positions, the northern flank of the terminal moraine, or coastal-plain sediments covered with basal till are exposed. Bottom photographs and video of boulders show that they are commonly covered with sessile fauna. Strong tidal currents have produced the deep scour depression along the northwestern edge of the study area. The eastern side of this depression is armored with a gravel lag. Sea-floor areas characterized by modern marine sediments appear featureless at the 2-meter resolution of the bathymetry and flat to current rippled in the photography. These modern environments are indicative of sediment sorting and reworking.
High Resolution Quaternary Seismic Stratigraphy of the New York Bight Continental Shelf
Schwab, William C.; Denny, J.F.; Foster, D.S.; Lotto, L.L.; Allison, M.A.; Uchupi, E.; Swift, B.A.; Danforth, W.W.; Thieler, E.R.; Butman, Bradford
2003-01-01
A principal focus for the U.S. Geological Survey (USGS) Coastal and Marine Geology Program (marine.usgs.gov) is regional reconnaissance mapping of inner-continental shelf areas, with initial emphasis on heavily used areas of the sea floor near major population centers. The objectives are to develop a detailed regional synthesis of the sea-floor geology in order to provide information for a wide range of management decisions and to form a basis for further investigations of marine geological processes. In 1995, the USGS, in cooperation with the U.S. Army Corps of Engineers (USACOE), New York District, began to generate reconnaissance maps of the continental shelf seaward of the New York - New Jersey metropolitan area. This mapping encompassed the New York Bight inner-continental shelf, one of the most heavily trafficked and exploited coastal regions in the United States. Contiguous areas of the Hudson Shelf Valley, the largest physiographic feature on this segment of the continental shelf, also were mapped as part of a USGS study of contaminated sediments (Buchholtz ten Brink and others, 1994; 1996). The goal of the reconnaissance mapping was to provide a regional synthesis of the sea-floor geology in the New York Bight area, including: (a) a description of sea-floor morphology; (b) a map of sea-floor sedimentary lithotypes; (c) the geometry and structure of the Cretaceous strata and Quaternary deposits; and (d) the geologic history of the region. Pursuing the course of this mapping effort, we obtained sidescan-sonar images of 100 % of the sea floor in the study area. Initial interpretations of these sidescan data were presented by Schwab and others, (1997a, 1997b, 2000a). High-resolution seismic-reflection profiles collected along each sidescan-sonar line used multiple acoustic sources (e.g., watergun, CHIRP, Geopulse). Multibeam swath-bathymetry data also were obtained for a portion of the study area (Butman and others, 1998;). In this report, we present a series of structural and sediment isopach maps and interpretations of the Quaternary evolution of the inner-continental shelf off the New York - New Jersey metropolitan area based on subbottom, sidescan-sonar, and multibeam-bathymetric data.
Pelvic Floor Physical Therapy and Women's Health Promotion.
Lawson, Samantha; Sacks, Ashley
2018-05-19
Pelvic floor dysfunction is defined as abnormal function of the pelvic floor and includes conditions that can have significant adverse impacts on a woman's quality of life, including urinary incontinence (stress, urge, and mixed), fecal incontinence, pelvic organ prolapse, sexual dysfunction, diastasis recti abdominis, pelvic girdle pain, and chronic pain syndromes. Women's health care providers can screen for, identify, and treat pelvic floor dysfunction. This article examines the case of a woman with multiple pelvic-floor-related problems and presents the evidence for the use of pelvic floor physical therapy (PFPT) for pregnancy-related pelvic floor dysfunction. PFPT is an evidence-based, low-risk, and minimally invasive intervention, and women's health care providers can counsel women about the role that PFPT may play in the prevention, treatment, and/or management of pelvic floor dysfunction. © 2018 by the American College of Nurse-Midwives.
Dobbs, Lauren K; Cunningham, Christopher L
2014-05-15
Methamphetamine (METH) indirectly stimulates the laterodorsal tegmental nucleus (LDT) acetylcholine (ACh) neurons to increase ACh within the ventral tegmental area (VTA). LDT ACh inhibition attenuates METH and saline locomotor activity. The aim of these experiments was to determine whether LDT ACh contributes to METH conditioned place preference (CPP). C57BL/6J mice received a bilateral electrolytic or sham lesion of the LDT. After recovery, mice received alternating pairings of METH (0.5 mg/kg) and saline with distinct tactile floor cues over 8 days. During preference tests, mice were given access to both floor types and time spent on each was recorded. Mice were tested again after exposure to both extinction and reconditioning trials. Brains were then processed for choline acetyltransferase immunohistochemistry to label LDT ACh neurons. Lesioned mice had significantly fewer LDT ACh neurons and showed increased saline and METH locomotor activity during the first conditioning trial compared to sham mice. Locomotor activity (saline and METH) was negatively correlated with the number of LDT ACh neurons. Lesioned and sham mice showed similar METH CPP following conditioning, extinction and reconditioning trials. LDT ACh neurons are not necessary for METH reward as indexed by CPP, but may be important for basal and METH-induced locomotor activity. Copyright © 2014 Elsevier B.V. All rights reserved.
75 FR 16651 - Airworthiness Directives; The Boeing Company Model 747-200C and -200F Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... upper chord of the upper deck floor beams in Area 5, and the inspection for fatigue cracking in the.... That AD currently requires repetitive inspections to find fatigue cracking in the floor panel... additional repetitive inspections to find fatigue cracking in the floor panel attachment fastener holes of...
Flooring choices for newborn ICUs.
White, R D
2007-12-01
Floors are a major element of newborn intensive care unit (NICU) construction. They provide visual cues, sound control, and with certain materials, some degree of physical comfort for workers. Flooring materials may entail a significant cost for installation and upkeep and can have substantial ecological impact, both in the choice of the flooring itself, as well as the substances used to clean it. In this article the important aspects to consider for each factor are explored and recommendations are offered for appropriate choices in various NICU areas.
Prevention of Salmonella cross-contamination in an oilmeal manufacturing plant.
Morita, T; Kitazawa, H; Iida, T; Kamata, S
2006-08-01
The mechanisms of Salmonella contamination in an oilmeal plant were investigated and the basic data were collected in order to achieve control of Salmonella in oilmeal. Salmonella was detected in all contamination vectors and environmental factors investigated, namely: operators, processing floor, dust in the air and rodents. In particular, high concentrations of Salmonella were detected on the processing floor of the manufacturing area, which has high oil content. Steam was the most effective disinfection method used for the processing floor, as the effects of heat sterilization and disinfection may work in tandem. In addition, restricting the movement of operators of the production chain remarkably reduced Salmonella contamination, even in areas of otherwise high contamination. Within the oilmeal plant, high Salmonella contamination rates for the processing floor represent the greatest risk of contamination of oilmeal via operators, dust in the air and rodents. Therefore, control of the processing floor is the most important means for reducing the oilmeal contamination rate. Specific Salmonella control methods for oilmeal plants have been established.
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING ...
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING MACHINE THAT REMOVES SHELL FRAGMENTS. METALLIC DUST REMOVED BY MAGNETIC SEPERATOR UNDERNEATH SCREEN. SAWDUST IS RETURNED TO SAWDUST HOPPER BY ELEVATOR. HOODS OVER SCREENING MACHINE AT WORKBENCH REMOVE FINE SAWDUST. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...
MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
49. TILE PACKING AREA AND APPRENTICE WORKSPACE, SECOND FLOOR, SOUTH ...
49. TILE PACKING AREA AND APPRENTICE WORKSPACE, SECOND FLOOR, SOUTH END OF EAST WING. THE SKYLIGHT, ADDED IN 1976. COVERS A ROOF OPENING LEFT FOR THE CHIMNEY OF A POSSIBLE THIRD BISCUIT KILN. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA
Students’ Mathematical Literacy in Solving PISA Problems Based on Keirsey Personality Theory
NASA Astrophysics Data System (ADS)
Masriyah; Firmansyah, M. H.
2018-01-01
This research is descriptive-qualitative research. The purpose is to describe students’ mathematical literacy in solving PISA on space and shape content based on Keirsey personality theory. The subjects are four junior high school students grade eight with guardian, artisan, rational or idealist personality. Data collecting methods used test and interview. Data of Keirsey Personality test, PISA test, and interview were analysed. Profile of mathematical literacy of each subject are described as follows. In formulating, guardian subject identified mathematical aspects are formula of rectangle area and sides length; significant variables are terms/conditions in problem and formula of ever encountered question; translated into mathematical language those are measurement and arithmetic operations. In employing, he devised and implemented strategies using ease of calculation on area-subtraction principle; declared truth of result but the reason was less correct; didn’t use and switch between different representations. In interpreting, he declared result as area of house floor; declared reasonableness according measurement estimation. In formulating, artisan subject identified mathematical aspects are plane and sides length; significant variables are solution procedure on both of daily problem and ever encountered question; translated into mathematical language those are measurement, variables, and arithmetic operations as well as symbol representation. In employing, he devised and implemented strategies using two design comparison; declared truth of result without reason; used symbol representation only. In interpreting, he expressed result as floor area of house; declared reasonableness according measurement estimation. In formulating, rational subject identified mathematical aspects are scale and sides length; significant variables are solution strategy on ever encountered question; translated into mathematical language those are measurement, variable, arithmetic operation as well as symbol and graphic representation. In employing, he devised and implemented strategies using additional plane forming on area-subtraction principle; declared truth of result according calculation process; used and switched between symbol and graphic representation. In interpreting, he declared result as house area within terrace and wall; declared reasonableness according measurement estimation. In formulating, idealist subject identified mathematical aspects are sides length; significant variables are terms/condition in problem; translated into mathematical language those are measurement, variables, arithmetic operations as well as symbol and graphic representation. In employing, he devised and implemented strategies using trial and error and two design in process of finding solutions; declared truth of result according the use of two design of solution; used and switched between symbol and graphic representation. In interpreting, he declared result as floor area of house; declared reasonableness according measurement estimation.
Jayasekara, Lalani; Leone, Cortney M; Sharp, Julia; Getty, Morgan
2016-09-01
In the U.S., 60% of norovirus outbreaks are attributed to long-term care facilities (LTCFs). A descriptive study of 26 LTCFs in South Carolina was conducted to determine the presence of environmental factors associated with transmission of human noroviruses. Sanitary conditions in one common area, one staff/visitor bathroom, and the main kitchen were assessed using two audit forms. While surfaces in all kitchens were in good sanitary condition, 23 LTCFs used quaternary ammonium-based sanitizers and three LTCFs used chlorine bleach for kitchen sanitization. All common areas were also clean and in good condition; however, 20 LTCFs had upholstered chairs, and five LTCFs had carpeted floors. Seven facilities used quaternary ammonium-based disinfectants exclusively, whereas six LTCFs used chlorine bleach exclusively, and eight LTCFs used both to disinfect common areas. Seven staff/visitor bathrooms were accessible to residents, and hand washing signage was missing from 10. These results reveal the presence of environmental factors that might facilitate norovirus transmission within LTCFs.
Investigating Mars: Rabe Crater
2017-12-14
This VIS image of Rabe Crater is dominated by the extensive dunes that cover the crater floor. To the top of the image part of the pit is visible, as well as a small peninsula that has been eroded into the upper level floor materials. On the upper elevation on the side left of the peninsula the dunes cascade onto the lower pit elevation. There is also a slight arc to the dunes on the pit floor due to how the peninsula changed the wind pattern. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 52206 Latitude: -43.6573 Longitude: 34.9551 Instrument: VIS Captured: 2013-09-20 13:07 https://photojournal.jpl.nasa.gov/catalog/PIA22142
Modelling the Interior Structure of Enceladus Based on the 2014's Cassini Gravity Data.
Taubner, R-S; Leitner, J J; Firneis, M G; Hitzenberger, R
2016-06-01
We present a model for the internal structure of Saturn's moon Enceladus. This model allows us to estimate the physical conditions at the bottom of the satellite's potential subsurface water reservoir and to determine the radial distribution of pressure and gravity. This leads to a better understanding of the physical and chemical conditions at the water/rock boundary. This boundary is the most promising area on icy moons for astrobiological studies as it could serve as a potential habitat for extraterrestrial life similar to terrestrial microbes that inhabit rocky mounds on Earth's sea floors.
Structural safety of trams in case of misguidance in a switch
NASA Astrophysics Data System (ADS)
Schindler, Christian; Schwickert, Martin; Simonis, Andreas
2010-08-01
Tram vehicles mainly operate on street tracks where sometimes misguidance in switches occurs due to unfavourable conditions. Generally, in this situation, the first running gear of the vehicle follows the bend track while the next running gears continue straight ahead. This leads to a constraint that can only be solved if the vehicle's articulation is damaged or the wheel derails. The last-mentioned situation is less critical in terms of safety and costs. Five different tram types, one of them high floor, the rest low floor, were examined analytically. Numerical simulation was used to determine which wheel would be the first to derail and what level of force is needed in the articulation area between two carbodies to make a tram derail. It was shown that with pure analytical simulation, only an idea of which tram type behaves better or worse in such a situation can be gained, while a three-dimensional computational simulation gives more realistic values for the forces that arise. Three of the four low-floor tram types need much higher articulation forces to make a wheel derail in a switch misguidance situation. One particular three-car type with two single-axle running gears underneath the centre car must be designed to withstand nearly three times higher articulation forces than a conventional high-floor articulated tram. Tram designers must be aware of that and should design the carbody accordingly.
The effects of surface condition on abdominal muscle activity during single-legged hold exercise.
Ha, Sung-min; Oh, Jae-seop; Jeon, In-cheol; Kwon, Oh-yun
2015-02-01
To treat low-back pain, various spinal stability exercises are commonly used to improve trunk muscle function and strength. Because human movement for normal daily activity occurs in multi-dimensions, the importance of exercise in multi-dimensions or on unstable surfaces has been emphasized. Recently, a motorized rotating platform (MRP) for facilitating multi-dimensions dynamic movement was introduced for clinical use. However, the abdominal muscle activity with this device has not been reported. The purpose of this study was to compare the abdominal muscle activity (rectus abdominis, external and internal oblique muscles) during an active single-leg-hold (SLH) exercise on a floor (stable surface), foam roll, and motorized rotating platform (MRP). Thirteen healthy male subjects participated in this study. Using electromyography, the abdominal muscle activity was measured while the subjects performed SLH exercises on floor (stable surface), foam roll, and MRP. There were significant differences in the abdominal muscle activities among conditions (P<.05), except for left EO (P>.05) (Fig. 2). After the Bonferroni correction, however, no significant differences among conditions remained, except for differences in both side IO muscle activity between the floor and foam roll conditions (padj<0.017). The findings suggest that performing the SLH exercises on a foam roll and MRP is more effective increased activities of both side of RA and IO, and Rt. EO compared to floor condition. However, there were no significant differences in abdominal muscles activity in the multiple comparison between conditions (mean difference were smaller than the standard deviation in the abdominal muscle activities) (padj>0.017), except for differences in both side IO muscle activity between the floor (stable surface) and foam roll (padj<0.017) (effect size: 0.79/0.62 (non-supporting/supporting leg) for foam-roll versus floor). Copyright © 2014 Elsevier Ltd. All rights reserved.
Floor Identification with Commercial Smartphones in Wifi-Based Indoor Localization System
NASA Astrophysics Data System (ADS)
Ai, H. J.; Liu, M. Y.; Shi, Y. M.; Zhao, J. Q.
2016-06-01
In this paper, we utilize novel sensors built-in commercial smart devices to propose a schema which can identify floors with high accuracy and efficiency. This schema can be divided into two modules: floor identifying and floor change detection. Floor identifying module starts at initial phase of positioning, and responsible for determining which floor the positioning start. We have estimated two methods to identify initial floor based on K-Nearest Neighbors (KNN) and BP Neural Network, respectively. In order to improve performance of KNN algorithm, we proposed a novel method based on weighting signal strength, which can identify floors robust and quickly. Floor change detection module turns on after entering into continues positioning procedure. In this module, sensors (such as accelerometer and barometer) of smart devices are used to determine whether the user is going up and down stairs or taking an elevator. This method has fused different kinds of sensor data and can adapt various motion pattern of users. We conduct our experiment with mobile client on Android Phone (Nexus 5) at a four-floors building with an open area between the second and third floor. The results demonstrate that our scheme can achieve an accuracy of 99% to identify floor and 97% to detecting floor changes as a whole.
13. Missile site control building, third and fourth floor interior, ...
13. Missile site control building, third and fourth floor interior, showing east corner and former electrical equipment area, room #306. This building was salvaged and sealed in the 1970's; the lower floors also suffered flooding - Stanley R. Mickelsen Safeguard Complex, Missile Site Control Building, Northeast of Tactical Road; southeast of Tactical Road South, Nekoma, Cavalier County, ND
137. ARAII Building ARA602 floor plan as it appeared in ...
137. ARA-II Building ARA-602 floor plan as it appeared in 1980 when electrical modifications were being made. Shows partial layout of floor plan. EG&G Idaho, Inc. 1570-ARA-II-602-E-3. Date: April 1980. Ineel index code no. 070--0602-10-220-159761. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
HOT CELL BUILDING, TRA632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED ...
HOT CELL BUILDING, TRA-632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED FLOOR LOADINGS AND CONCRETE SLAB THICKNESSES, A TYPICAL FEATURE OF NUCLEAR ARCHITECTURE. IDAHO OPERATIONS OFFICE MTR-632-IDO-2, 11/1952. INL INDEX NO. 531-0632-62-396-110561, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kendall, J.; Hams, J.E.; Buck, S.P.
1990-05-01
Advances in high resolution side-scan sonar imaging technology are so effective at imaging sea-floor geology that they have greatly improved the efficiency of a bottom sampling program The traditional sea-floor geology methodology of shooting a high-resolution seismic survey and sampling along the seismic grid was considered successful if outcrops were sampled on 20% of the attempts. A submersible was used sparingly because of the inability to consistently locate sea-floor outcrops. Side-scan sonar images have increased the sampling success ratio to 70-95% and allow the cost-effective use of a submersible even in areas of sparse sea-floor outcrops. In offshore basins thismore » new technology has been used in consolidated and semiconsolidated rock terranes. When combined with observations from a two-man submersible, SCUBA traverses, seismic data, and traditional sea-floor bottom sampling techniques, enough data are provided to develop an integrated sea-floor geologic interpretation. On individual prospects, side-scan sonar has aided the establishment of critical dip in poor seismic data areas, located seeps and tar mounds, and determined erosional breaching of a prospect. Over a mature producing field, side-scan sonar has influenced the search for field extension by documenting the orientation and location of critical trapping cross faults. These relatively inexpensive techniques can provide critical data in any marine basin where rocks crop out on the sea floor.« less
11. INTERIOR VIEW OF BALCONY FROM GROUND FLOOR LEVEL. ...
11. INTERIOR VIEW OF BALCONY FROM GROUND FLOOR LEVEL. - Wright-Patterson Air Force Base, Area B, Building No. 12, Technical Data Building, Third Street, between B & D Streets, Dayton, Montgomery County, OH
18. MAINTENANCE SHOP, FIRST FLOOR, INTERIOR, ENGINE AND AIRPLANE OVERHAUL ...
18. MAINTENANCE SHOP, FIRST FLOOR, INTERIOR, ENGINE AND AIRPLANE OVERHAUL AREAS; LOOKING EAST - Northwest Airways Hangar & Administration Building, 590 Bayfield Street, St. Paul Downtown Airport (Holman), Saint Paul, Ramsey County, MN
17. MAINTENANCE SHOP, FIRST FLOOR, INTERIOR, ENGINE AND AIRPLANE OVERHAUL ...
17. MAINTENANCE SHOP, FIRST FLOOR, INTERIOR, ENGINE AND AIRPLANE OVERHAUL AREAS; LOOKING WEST. - Northwest Airways Hangar & Administration Building, 590 Bayfield Street, St. Paul Downtown Airport (Holman), Saint Paul, Ramsey County, MN
VIEW FACING EAST LOOKING DOWN FROM OPEN HEARTH TAPPING FLOOR ...
VIEW FACING EAST LOOKING DOWN FROM OPEN HEARTH TAPPING FLOOR AREA, NOTE FOUNDATIONS OF OPEN HEARTH FURNACES. - Pittsburgh Steel Company, Monessen Works, Open Hearth Plant, Donner Avenue, Monessen, Westmoreland County, PA
Building G interior, second floor oblique looking southwest, showing storage ...
Building G interior, second floor oblique looking southwest, showing storage area for samples - Daniel F. Waters Germantown Dye Works, Building G, 37-55 East Wister Street, Philadelphia, Philadelphia County, PA
McMullen, K.Y.; Poppe, L.J.; Ackerman, S.D.; Blackwood, D.S.; Schaer, J.D.; Nadeau, M.A.; Wood, D.A.
2011-01-01
The U.S. Geological Survey (USGS) and the National Oceanic and Atmospheric Administration (NOAA) are working together to study sea-floor environments off the northeast coast of the United States. During 2008, NOAA survey H11996 collected multibeam echosounder data in a 65-square kilometer area in central Rhode Island Sound, southeast of Point Judith, Rhode Island. During 2010, the USGS collected bottom photographs and sediment samples from 25 stations in this study area. The bathymetry, photography, and sediment data are used to interpret sea-floor features including scour depressions, sand waves, trawl marks, and dredge spoils. Scour depressions cover the bathymetric highs in much of the study area. Sand waves are located mostly in the southwest, and trawl marks tend to be in the northern regions. Dredge spoils are located at a disposal site in a bathymetric low in the western end of the study area. Most stations have a sea-floor surface of sand or silty sand, but eight of the stations have boulders to pea-sized gravel or gravelly sediment on the surface. Photographs show sandy areas typically have scattered burrows, shells, amphipod communities, and worm tubes. Boulders and cobbles are commonly overgrown with hydrozoans and anemones.
41 CFR 102-74.180 - What illumination levels must Federal agencies maintain on Federal facilities?
Code of Federal Regulations, 2010 CFR
2010-07-01
... surfaces, measured at a height of 30 inches above floor level, during working hours (for visually difficult...) 30 foot-candles in work areas during working hours, measured at 30 inches above floor level; (c) 10 foot-candles, but not less than 1 foot-candle, in non-work areas, during working hours (normally this...
127. ARAII Administrative and technical support building (ARA606) ground floor ...
127. ARA-II Administrative and technical support building (ARA-606) ground floor plan. Indicates use of rooms for classrooms, offices, and lunch room. C.A. Sundberg and Associates 866-area-ALPR-606-A-2. Date: June 1958. Ineel index code no. 070-0606-00-822-102825. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
16. VIEW TO NORTHEAST OF SECONDFLOOR ASSEMBLY AREA FROM NEAR ...
16. VIEW TO NORTHEAST OF SECOND-FLOOR ASSEMBLY AREA FROM NEAR SOUTHWEST WEST. NOTE DIFFERENCE IN ROOF STRUCTURE BETWEEN SAWTOOTH SKYLIGHTS OVER MOST OF THE SECOND FLOOR (RIGHT) AND THE PORTION OF THE ROOF RUNNING ALONG THE WEST EDGE OF THE BUILDING (LEFT). - Rosie the Riveter National Historical Park, Ford Assembly Plant, 1400 Harbour Way South, Richmond, Contra Costa County, CA
MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR MEZZANINE: LUNCH AND ...
MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR MEZZANINE: LUNCH AND CONFERENCE ROOM, STORAGE AREA, OFFICES FOR FOREMEN, STENOS, ENGINEERS, DISPATCHER, WOMEN'S RESTROOM. HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-12, 2/1958. INL INDEX NO. 532-0653-00-381-102837, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
11. The work area of a typical fuel storage and ...
11. The work area of a typical fuel storage and transfer basin. The wooden floor was built over the 20-foot deep water-filled basin. Buckets filled with irradiated fuel of dummy slugs in the floor and were hung on trolleys attached to the monorail tracks suspended from the ceiling. 85-H807 - B Reactor, Richland, Benton County, WA
Ait Bamai, Yu; Araki, Atsuko; Kawai, Toshio; Tsuboi, Tazuru; Saito, Ikue; Yoshioka, Eiji; Kanazawa, Ayako; Tajima, Shuji; Shi, Cong; Tamakoshi, Akiko; Kishi, Reiko
2014-01-15
Phthalates are widely used as plasticizers in numerous products. However, there has been some concern about the various effects they may have on human health. Thus, household phthalate levels are an important public health issue. While many studies have assessed phthalate levels in house dust, the association of these levels with building characteristics has scarcely been examined. The present study investigated phthalate levels in house dust samples collected from the living areas of homes, and examined associations between these phthalate levels and the interior materials. Dust was collected from two portions of the living area: floor dust from the entire floor surface, and multi-surface dust from objects more than 35 cm above the floor. The levels of seven phthalates were measured using gas chromatography/mass spectrometry in selective ion monitoring mode. Phthalate levels were higher in multi-surface dust than in floor dust. Among floor dust samples, those from dwellings with compressed wooden flooring had significantly higher levels of di-iso-butyl phthalate compared to those with other floor materials, while polyvinyl chloride (PVC) flooring was associated with higher di-2-ethylhexyl phthalate (DEHP) levels. Among multi-surface dust samples, higher levels of DEHP and di-iso-nonyl phthalate (DINP) were found in samples from homes with PVC wallpaper than without. The number of PVC interior materials was significantly positively correlated with the levels of DEHP and DINP in multi-surface dust. The phthalate levels in multi-surface dust were associated with the interior surface materials, and those in floor dust were directly related to the flooring materials. Our findings show that when using house dust as an exposure assessment, it is very important to note where the samples were collected from. The present report provides useful information about the association between phthalates and dust inside dwellings, which will assist with establishing public health provisions. © 2013. Published by Elsevier B.V. All rights reserved.
Novel safety floors do not influence early compensatory balance reactions in older adults.
Wright, Alexander D; Heckman, George A; McIlroy, William E; Laing, Andrew C
2014-01-01
Novel safety flooring systems are a promising approach for reducing fall-related injuries in seniors, as they have been demonstrated to substantially reduce impact severity during falls, while minimally impairing balance control in community-dwelling older women. This pilot study aimed to characterize the potential effects of flooring conditions on dynamic balance control in retirement home-dwellers with more limited mobility. A tether-release paradigm was used to simulate a trip-type perturbation in 15 seniors across five flooring surfaces (three novel safety floors and one carpet compared to institutional-grade resilient rolled-sheeting). Kinetic and kinematic data tracked the displacement profiles of the underfoot centre-of-pressure and whole-body centre-of-mass, which were used to characterize compensatory balance reactions. Difference tests (ANOVA) found that the onset of the compensatory balance reaction was not associated with floor condition, nor were the timing and magnitude of peak centre-of-pressure excursion (minimum margin of safety) and velocity. Accordingly, the minimum margin of safety of the centre-of-mass was not significantly different across floors. Equivalence tests supported these findings. This study provides evidence that the carpet and novel safety floors tested do not negatively influence characteristics of initial dynamic balance responses following a lean-and-release perturbation compared to an institutional-grade resilient rolled-sheeting surface. In combination with reports of substantial force attenuative properties during fall-related impacts, these findings support the promise of novel safety floors as a biomechanically effective strategy for reducing fall-related injuries. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Riber, A B; Hinrichsen, L K
2016-07-01
Feather eating has been associated with feather pecking, which continues to pose economic and welfare problems in egg production. Knowledge on feather eating is limited and studies of feather eating in commercial flocks of laying hens have not been performed previously. Therefore, the main objective was to investigate feather eating and its association with plumage damage and floor feather characteristics in commercial flocks of layers in barn and organic production systems. The study was performed in 13 flocks of barn layers and 17 flocks of organic layers. Each flock was visited at around 32 and 62 weeks of age. During both visits, the plumage condition was assessed and the density of floor feathers recorded. In week 62, droppings and floor feathers were collected. Droppings were examined for presence of feather content, whereas length, downiness and pecking damage were recorded for each floor feather. In week 62, a higher prevalence of hens with poor plumage condition was found in barn (22.2%) compared with organic production systems (7.4%; P<0.001), but the prevalence of droppings with feather content did not differ between the two production systems (8.5% in barn v. 4.3% in organic; P=0.99). Our hypothesis about a positive correlation between feather eating and plumage damage was not supported as no correlation was found between the prevalence of poor plumage condition and the prevalence of droppings with feather content. However, the prevalence of pecking damaged floor feathers was positively correlated both with prevalence of droppings with feather content (P<0.05) and poor plumage condition (P<0.01), indicating a possible association between feather eating and feather pecking. In conclusion, it was confirmed that feather eating occurs on-farm, but feather eating was only found to be positively correlated to the number of floor feathers with pecking damage and not as expected to the prevalence of plumage damage. More research is needed into the sources from where feathers are selected for ingestion, that is, whether they are picked from the floor litter, plucked directly from other hens or dislodged during preening of own feathers.
Biomechanical paradigm and interpretation of female pelvic floor conditions before a treatment
Lucente, Vincent; van Raalte, Heather; Murphy, Miles; Egorov, Vladimir
2017-01-01
Background Further progress in restoring a woman’s health may be possible if a patient with a damaged pelvic floor could undergo medical imaging and biomechanical diagnostic tests. The results of such tests could contribute to the analysis of multiple treatment options and suggest the optimal one for that patient. Aim To develop a new approach for the biomechanical characterization of vaginal conditions, muscles, and connective tissues in the female pelvic floor. Methods Vaginal tactile imaging (VTI) allows biomechanical assessment of the soft tissue along the entire length of the anterior, posterior, and lateral vaginal walls at rest, with manually applied deflection pressures and with muscle contraction, muscle relaxation, and Valsalva maneuver. VTI allows a large body of measurements to evaluate individual variations in tissue elasticity, support defects, as well as pelvic muscle function. Presuming that 1) the female pelvic floor organs are suspended by ligaments against which muscles contract to open or close the outlets and 2) damaged ligaments weaken the support and may reduce the force of muscle contraction, we made an attempt to characterize multiple pelvic floor structures from VTI data. Results All of the 138 women enrolled in the study were successfully examined with the VTI. The study subjects have had normal pelvic support or pelvic organ prolapse (stages I–IV). The average age of this group of subjects was 60±15 years. We transposed a set of 31 VTI parameters into a quantitative characterization of pelvic muscles and ligamentous structures. Interpretation of the acquired VTI data for normal pelvic floor support and prolapse conditions is proposed based on biomechanical assessment of the functional anatomy. Conclusion Vaginal tactile imaging allows biomechanical characterization of female pelvic floor structures and tissues in vivo, which may help to optimize treatment of the diseased conditions such as prolapse, incontinence, atrophy, and some forms of pelvic pain. PMID:28831274
10. Interior view, east shop, ground floor, looking northwest, showing ...
10. Interior view, east shop, ground floor, looking northwest, showing hardware storage rooms in tin shop area at right. - Larrabee & Hingston Company, Main Shop Building, 19 Howley Street, Peabody, Essex County, MA
Looking Southeast from Second Floor Mezzanine of Pellet Plant to ...
Looking Southeast from Second Floor Mezzanine of Pellet Plant to Erbia Mixing Area and Poreformer and Acrawax Mixing Station - Hematite Fuel Fabrication Facility, Pellet Plant, 3300 State Road P, Festus, Jefferson County, MO
5. ROOF DETAIL, LOOKING EAST TOWARD SECOND FLOOR WAREHOUSE FROM ...
5. ROOF DETAIL, LOOKING EAST TOWARD SECOND FLOOR WAREHOUSE FROM ROOF OF ASSEMBLY AREA. - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA
PBF (PER620) interior. Counting room, main floor. Date: May 2004. ...
PBF (PER-620) interior. Counting room, main floor. Date: May 2004. INEEL negative no. HD-41-6-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Female Pelvic Floor Biomechanics: Bridging the Gap
Easley, Deanna C.; Abramowitch, Steven D.; Moalli, Pamela A.
2017-01-01
Purpose of review The pelvic floor is a complex assembly of connective tissues and striated muscle that simultaneously counteract gravitational forces, inertial forces, and intraabdominal pressures while maintaining the position of the pelvic organs. In 30% of women, injury or failure of the pelvic floor results in pelvic organ prolapse (POP). Surgical treatments have high recurrence rates, due, in part, to a limited understanding of physiologic loading conditions. It is critical to apply biomechanics to help elucidate how altered loading conditions of the pelvis contribute to the development of pelvic organ prolapse and to define surgeries to restore normal support. Recent findings Evidence suggests the ewe is a potential animal model for studying vaginal properties and that uterosacral and cardinal ligaments experience significant creep, which may be affecting surgical outcomes. A new method of measuring ligament displacements in vivo was developed, and finite element models that simulate urethral support, pelvic floor dynamics, and the impact of episiotomies on the pelvic floor were studied. Summary This review highlights some contributions over the past year, including mechanical testing and the creation of models, which are used to understand pelvic floor changes with loading, and the impact of surgical procedures, to illustrate how biomechanics is being utilized. PMID:28267057
Localization of wood floor structure by infrared thermography
NASA Astrophysics Data System (ADS)
Cochior Plescanu, C.; Klein, M.; Ibarra-Castanedo, C.; Bendada, A.; Maldague, X.
2008-03-01
One of our industrial partners, Assek Technologie, is interested in developing a technique that would improve the drying process of wood floor in basements after flooding. In order to optimize the procedure, the floor structure and the damaged (wet) area extent must first be determined with minimum intrusion (minimum or no dismantling). The present study presents the use of infrared thermography to reveal the structure of (flooded) wood floors. The procedure involves opening holes in the floor. Injecting some hot air through those holes reveals the framing structure even if the floor is covered by vinyl or ceramic tiles. This study indicates that thermal imaging can also be used as a tool to validate the decontamination process after drying. Thermal images were obtained on small-scale models and in a demonstration room.
Effects of neoprene mat on diarrhea, mortality and foreleg abrasion of pre-weaning piglets.
Gu, Zhaobing; Xin, Hongwei; Wang, Chaoyuan; Shi, Zhengxiang; Liu, Zuohua; Yang, Feiyun; Lin, Baozhong; Wang, Chao; Li, Baoming
2010-06-01
Modern commercial swine farrowing crates are typically equipped with slatted iron floor to improve management efficiency (e.g., ease of manure handling, cleanliness of the farrowing crates and hence improved animal hygiene). However, the bare and hard floor surface can impair the welfare of the sow-litter because of some undesirable impacts on the pigs, such as foreleg abrasion, large temperature gradients between the cold floor surface and the abdomen of the piglets (hence higher susceptibility to diarrhea), and higher pre-weaning mortality or morbidity. Although straw bedding has been shown to be conducive to providing better environment for the sow-litter, use of straw creates challenges in terms of economics, hygiene and manure handling. This study investigates the use of neoprene mat (NM) in key areas of the farrowing crates - underneath the sow and in the piglet suckling area to improve the microenvironment and hence welfare of the sow-litter. Two experiments were conducted, each involving 12 sow-litters. The first experiment was to evaluate the thickness of a rectangular-shaped NM (7, 10 or 13 mm) vs. the slatted iron floor (control or Ctrl) and collect the corresponding animal response data; while the second follow-up experiment was to verify the benefits of supplying an improved, double concave (or H)-shaped NM with 10mm thick (CNM10) vs. Ctrl for the farrowing operation. Results of both experiments demonstrated considerable benefits of the NM placement in the farrowing crates. Specifically, the NM reduced the piglet foreleg lesion area and joint swellings (0% for NM vs. 8-10% for Ctrl during suckling periods in both Expts 1 and 2, P<0.001); reduced pre-weaning piglet crushing mortality (18.5+/-5.0%, 6.7+/-3.3% and 9.1+/-5.2% and for Ctrl, NM7 and NM10 and in Expt 1, P<0.05); and reduced piglet diarrhea morbidity (0.6+/-0.2% for CNM10 vs. 2.7+/-0.3% for Ctrl in Expt 2, P<0.01). Piglets in the NM litters had smaller temperature gradients between the abdomen and the contact floor surface (3.8+/-2.3 degrees C for NM vs. 7.6+/-0.5 degrees C for Ctrl in Expt 1, P<0.001; 9.2+/-0.5 degrees C for CNM10 vs. 15.9+/-0.5 degrees C for Ctrl in Expt 2, P<0.001). Moreover, sows in the NM regimens showed longer transition time when changing from standing to lying position (7.4+/-0.3s for CNM10 vs. 4.5+/-0.2s for Ctrl in Expt 2, P<0.05), indicative of more floor comfort for the NM condition. Results of this study suggest that supply of NM underneath the sow and in the piglet suckling area is conducive to enhancing comfort, health and welfare of the sow and litter. (c) 2010 Elsevier B.V. All rights reserved.
Pietsch, Hollie A; Bosch, Kelly E; Weyland, David R; Spratley, E Meade; Henderson, Kyvory A; Salzar, Robert S; Smith, Terrance A; Sagara, Brandon M; Demetropoulos, Constantine K; Dooley, Christopher J; Merkle, Andrew C
2016-11-01
Three laboratory simulated sub-injurious under-body blast (UBB) test conditions were conducted with whole-body Post Mortem Human Surrogates (PMHS) and the Warrior Assessment Injury Manikin (WIAMan) Technology Demonstrator (TD) to establish and assess UBB biofidelity of the WIAMan TD. Test conditions included a rigid floor and rigid seat with independently varied pulses. On the floor, peak velocities of 4 m/s and 6 m/s were applied with a 5 ms time to peak (TTP). The seat peak velocity was 4 m/s with varied TTP of 5 and 10 ms. Tests were conducted with and without personal protective equipment (PPE). PMHS response data was compiled into preliminary biofidelity response corridors (BRCs), which served as evaluation metrics for the WIAMan TD. Each WIAMan TD response was evaluated against the PMHS preliminary BRC for the loading and unloading phase of the signal time history using Correlation Analysis (CORA) software to assign a numerical score between 0 and 1. A weighted average of all responses was calculated to determine body region and whole body biofidelity scores for each test condition. The WIAMan TD received UBB biofidelity scores of 0.62 in Condition A, 0.59 in Condition B, and 0.63 in Condition C, putting it in the fair category (0.44-0.65). Body region responses with scores below a rating of good (0.65-0.84) indicate potential focus areas for the next generation of the WIAMan design.
2010-01-01
Background Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. Methods The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. Results The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. Conclusions The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies. PMID:20584307
Hesse, Stefan; Waldner, Andreas; Tomelleri, Christopher
2010-06-28
Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies.
Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.
Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho
2016-03-15
Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Halmeenmäki, Elisa; Peltola, Olli; Haikarainen, Iikka; Ryhti, Kira; Rannik, Üllar; Pihlatie, Mari
2017-04-01
Methane (CH4) is an important and strong greenhouse gas of which atmospheric concentration is rising. While boreal forests are considered as an important sink of CH4 due to soil CH4 oxidation, the soils have also a capacity to emit CH4. Moreover, vegetation is shown to contribute to the ecosystem-atmosphere CH4 flux, and it has been estimated to be the least well known natural sources of CH4. In addition to well-known CH4 emissions from wetland plants, even boreal trees have been discovered to emit CH4. At the SMEAR (Station for Measuring Ecosystem-Atmosphere Relations) II station in Hyytiälä, southern Finland (61° 51' N, 24°17' E; 181 m asl), we have detected small CH4 emissions from above the canopy of a Scots pine (Pinus sylvestris) dominated forest. To assess the origin of the observed emissions, we conducted forest floor CH4 flux measurements with 54 soil chambers at the footprint area of the above canopy flux measurements during two growing seasons. In addition, we measured the soil volumetric water content (VWC) every time next to the forest floor chamber measurements, and estimated vegetation coverages inside the chambers. In order to model the forest floor CH4 flux at the whole footprint area, we combined lidar (light detection and ranging) data with the field measurements. To predict the soil water content and thus the potential CH4 flux, we used local elevation, slope, and ground return intensity (GRI), calculated from the lidar data (National Land Survey of Finland). We categorized the soil chambers into four classes based on the VWC so that the class with the highest VWC values includes all the soil chambers with a potential to emit CH4. Based on a statistically significant correlation between the VWC and the forest floor CH4 flux (r = 0.30, p < 0.001), we modelled the potential forest floor CH4 flux of the whole area. The results of the soil chamber measurements show a few areas of the forest floor with significant CH4 emissions. The modelled map of the potential CH4 flux is consistent with the measurements of the flux and the VWC, indicating that the wetter areas have potential for CH4 emissions, while the drier areas have potential for CH4 uptake. Preliminary results of the vegetation coverage show a positive correlation between the first year forest floor CH4 flux and the coverage of Sphagnum spp. mosses (r = 0.55, p < 0.001). Furthermore, we will include the vegetation coverage to the analysis, and compare the modelled forest floor CH4 flux with the measured above canopy flux. This ongoing research will give valuable information about the CH4 sources and dynamics in boreal forests.
20. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT AREA ...
20. VIEW OF THE BASEMENT FLOOR PLAN. THE BASEMENT AREA INCLUDES A UTILITY ROOM, PROCESS WASTE STORAGE AND MAINTENANCE AREAS, AND THE ENTRANCE TO AN UNDERGROUND TUNNEL LEADING TO BUILDING 881. THE ORIGINAL DRAWING HAS BEEN ARCHIVED ON MICROFILM. THE DRAWING WAS REPRODUCED AT THE BEST QUALITY POSSIBLE. LETTERS AND NUMBERS IN THE CIRCLES INDICATE FOOTER AND/OR COLUMN LOCATIONS. - Rocky Flats Plant, Uranium Rolling & Forming Operations, Southeast section of plant, southeast quadrant of intersection of Central Avenue & Eighth Street, Golden, Jefferson County, CO
26. View of second floor of transmitter building no. 102 ...
26. View of second floor of transmitter building no. 102 looking across electronic equipment cabinets in area of missile impact predictor (MIP) area. Note U.S. Air Force emblem in mid-center of photograph. This area is in front of the Missile Warning Operations Center (MWOC) office. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Beschorner, Kurt E.; Albert, Devon L.; Chambers, April J.; Redfern, Mark S.
2018-01-01
Previous research on slip and fall accidents has suggested that pressurized fluid between the shoe and floor is responsible for initiating slips yet this effect has not been verified experimentally. This study aimed to 1) measure hydrodynamic pressures during slipping for treaded and untreaded conditions; 2) determine the effects of fluid pressure on slip severity; and 3) quantify how fluid pressures vary with instantaneous resultant slipping speed, position on the shoe surface, and throughout the progression of the slip. Eighteen subjects walked on known dry and unexpected slippery floors, while wearing treaded and untreaded shoes. Fluid pressure sensors, embedded in the floor, recorded hydrodynamic pressures during slipping. The maximum fluid pressures (mean+/−standard deviation) were significantly higher for the untreaded conditions (124 +/−75 kPa) than the treaded conditions (1.1 +/−0.29 kPa). Maximum fluid pressures were positively correlated with peak slipping speed (r = 0.87), suggesting that higher fluid pressures, which are associated with untreaded conditions, resulted in more severe slips. Instantaneous resultant slipping speed and position of sensor relative to the shoe sole and walking direction explained 41% of the fluid pressure variability. Fluid pressures were primarily observed for untreaded conditions. This study confirms that fluid pressures are relevant to slipping events, consistent with fluid dynamics theory (i.e. the Reynolds equation), and can be modified with shoe tread design. The results suggest that the occurrence and severity of unexpected slips can be reduced by designing shoes/floors that reduce underfoot fluid pressures. PMID:24267270
25. Similar view of lobby area on first floor transmitter ...
25. Similar view of lobby area on first floor transmitter building no. 102 looking at door in photograph AK-30-A-24 in closed position showing locking system and restricted access notification. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Ahearn, D G; Crow, S A; Simmons, R B; Price, D L; Noble, J A; Mishra, S K; Pierson, D L
1996-05-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
NASA Technical Reports Server (NTRS)
Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.
1996-01-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
Impact of a large flood on mountain river habitats, channel morphology, and valley infrastructure
NASA Astrophysics Data System (ADS)
Hajdukiewicz, Hanna; Wyżga, Bartłomiej; Mikuś, Paweł; Zawiejska, Joanna; Radecki-Pawlik, Artur
2016-11-01
The Biała River, Polish Carpathians, was considerably modified by channelization and channel incision in the twentieth century. To restore the Biała, establishing an erodible corridor was proposed in two river sections located in its mountain and foothill course. In these sections, longer, unmanaged channel reaches alternate with short, channelized reaches; and channel narrowing and incision increases in the downstream direction. In June 2010 an 80-year flood occurred on the river; and this study aims at determining its effects on physical habitat conditions for river biota, channel morphology, and valley-floor infrastructure. Surveys of 10 pairs of closely located, unmanaged and channelized cross sections, performed in 2009 and in the late summer 2010, allowed us to assess the flood-induced changes to physical habitat conditions. A comparison of channel planforms determined before (2009) and after (2012) the flood provided information on the degree of channel widening as well as changes in the width of particular elements of the river's active zone in eight stretches of the Biała. The impact of the flood on valley-floor infrastructure was confronted with the degree of river widening in unmanaged and channelized river reaches. Before the flood, unmanaged cross sections were typified by finer bed material and greater lateral variability in depth-averaged and near-bed flow velocity than channelized cross sections. The flood tended to equalize habitat conditions in both types of river cross sections, obliterating differences (in particular physical habitat parameters) between channelized and unmanaged channel reaches. River widening mostly reflected an increase in the area of channel bars, whereas the widening of low-flow channels was less pronounced. A comparison of channel planform from 2009 and 2012 indicated that intense channel incision typical of downstream sections limited river widening by the flood. Active channel width increased by half in the unmanaged cross sections and by one-third in the channelized cross sections. However, damage to the valley-floor infrastructure was practically limited to the channelized river reaches with reinforced channel banks. This indicates incompetent management of riparian areas rather than the degree of river widening as a principal reason for the economic losses during the flood.
16. VIEW OF FIRST FLOOR EAST OPERATING GALLERY. NOTE THE ...
16. VIEW OF FIRST FLOOR EAST OPERATING GALLERY. NOTE THE SERIES OF MANIPULATOR ARMS ALONG THE LEFT WALL. - Nevada Test Site, Engine Maintenance Assembly & Disassembly Facility, Area 25, Jackass Flats, Mercury, Nye County, NV
View from second floor platform looking up at subsequent platforms. ...
View from second floor platform looking up at subsequent platforms. Note the Shuttle assembly outlined by the platform edges. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL
17. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, MALE ...
17. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, MALE MEDIUM SECURITY SLEEPING AREA. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI
Vallejo family sleeping space, west wing, upper floor, looking north ...
Vallejo family sleeping space, west wing, upper floor, looking north from the south end. The doorway at far right connects with the dining area. - Vallejo Adobe, Adobe Road at Casa Grande, Petaluma, Sonoma County, CA
Floor Plans Level 15 Load Platform, Level 17 Lower ...
Floor Plans - Level 15 Load Platform, Level 17 Lower Platform, Level 22 and Upper Platform, and Level 27 - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
INTERIOR VIEW OF FIRST FLOOR HALLWAY FROM THE EAST END ...
INTERIOR VIEW OF FIRST FLOOR HALLWAY FROM THE EAST END OF BUILDING 63, FACING WEST. - Naval Computer & Telecommunications Area Station, Enlisted Men's Barracks, West corner of Central Street & Midway Drive, Wahiawa, Honolulu County, HI
McMullen, K.Y.; Poppe, L.J.; DiGiacomo-Cohen, M. L.; Moser, M.S.; Christman, E.B.
2005-01-01
We used sidescan-sonar imagery detailing almost 300 km2 of the sea floor in west-central Long Island Sound in conjunction with bathymetry, sediment samples, bottom video, and seismic data to interpret the area's surficial geology. The distribution of sediments and sedimentary environments interpreted from these data sets represents the Quaternary geology, regional bathymetry, and effects of modern tidal- and wave-driven currents. Four distinct sedimentary environments consisting of 1) fine-grained deposition, 2) sorting and reworking, 3) coarse-grained bedload transport, and 4) erosion or nondeposition, were identified and mapped. Relatively low-energy environments prevail where deposition of clayey silts occurs in deeper water throughout the central part of the study area, and in the protected areas of the far northeastern corner. As low-energy environments transition to relatively high-energy environments, sorting and reworking of sand, silty sand, and sand-silt-clay takes place on the flanks of the shoals and over smaller bathymetric highs. Environments of coarse-grained bedload transport, distinguished by sandy sediments with current-derived bedforms, are located on an unnamed shoal in the northwestern part of the study area and directly to the south of this on Stratford Shoal. High-energy conditions are reflected by environments of erosion or nondeposition, which occur on bathymetric highs where gravel and gravelly sediments are present.
ETR, TRA642. CONSOLE FLOOR. CAMERA IS ON WEST SIDE OF ...
ETR, TRA-642. CONSOLE FLOOR. CAMERA IS ON WEST SIDE OF FLOOR AND FACES NORTH. OUTER WALL OF STORAGE CANAL IS AT RIGHT. SHIELDING IS THICKER AT LOWER LEVEL, WHERE SPENT FUEL ELEMENTS WILL COOL AFTER REMOVAL FROM REACTOR. INL NEGATIVE NO. 56-1401. Jack L. Anderson, Photographer, 5/1/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Samuel V. Glass; Charles G. Carll; Jay P. Curole; Matthew D. Voitier
2010-01-01
In flood-prone areas, elevating a buildingâs floor system above the anticipated flood level can significantly limit the extent of property damage associated with flooding. In hot and humid climates, such as the Gulf Coast region, raised floor systems may, however, be at risk for seasonal moisture accumulation, as the majority of residential buildings in such climates...
Study of traffic noise levels at various heights of a 39-story building
Norman L. Meyerson
1977-01-01
Comparative measurements of exterior noise levels made at floors 3, 14, 26, and 37 of a high-rise apartment tower, when presented as a statistical distribution of percent exceedance vs. decibels, show the nature of the influence of local traffic at the low floors compared to the influence of an area source at the high floors. The open window penalty to interior noise...
Sarah A. Lewis; Andrew T. Hudak; Roger D. Ottmar; Peter R. Robichaud; Leigh B. Lentile; Sharon M. Hood; James B. Cronan; Penny Morgan
2011-01-01
Wildfire is a major forest disturbance in interior Alaska that can both directly and indirectly alter ecological processes. We used a combination of pre- and post-fire forest floor depths and post-fire ground cover assessments measured in the field, and high-resolution airborne hyperspectral imagery, to map forest floor conditions after the 2004 Taylor Complex in...
Sea-Floor geology and character of Eastern Rhode Island Sound West of Gay Head, Massachusetts
Poppe, L.J.; McMullen, K.Y.; Ackerman, S.D.; Blackwood, D.S.; Irwin, B.J.; Schaer, J.D.; Forrest, M.R.
2011-01-01
Gridded multibeam bathymetry covers approximately 102 square kilometers of sea floor in eastern Rhode Island Sound west of Gay Head, Massachusetts. Although originally collected for charting purposes during National Oceanic and Atmospheric Administration hydrographic survey H11922, these acoustic data and the sea-floor stations subsequently occupied to verify them (1) show the composition and terrain of the seabed, (2) provide information on sediment transport and benthic habitat, and (3) are part of an expanding series of studies that provide a fundamental framework for research and management activities (for example, windfarms and fisheries) along the Massachusetts inner continental shelf. Most of the sea floor in the study area has an undulating to faintly rippled appearance and is composed of bioturbated muddy sand, reflecting processes associated with sediment sorting and reworking. Shallower areas are composed of rippled sand and, where small fields of megaripples are present, indicate sedimentary environments characterized by processes associated with coarse bedload transport. Boulders and gravel were found on the floors of scour depressions and on top of an isolated bathymetric high where erosion has removed the Holocene marine sediments and exposed the underlying relict lag deposits of Pleistocene drift. The numerous scour depressions, which formed during storm-driven events, result in the juxtaposition of sea-floor areas with contrasting sedimentary environments and distinct gravel, sand, and muddy sand textures. This textural heterogeneity in turn creates a complex patchwork of habitats. Our observations of local variations in community structure suggest that this small-scale textural heterogeneity adds dramatically to the sound-wide benthic biological diversity.
Investigating Mars: Rabe Crater
2017-12-11
Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. In this VIS image the rim of the pit is visible near the top of the image. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 17074 Latitude: -43.6954 Longitude: 34.66 Instrument: VIS Captured: 2005-10-20 04:05 https://photojournal.jpl.nasa.gov/catalog/PIA22139
Investigating Mars: Rabe Crater
2017-12-15
This VIS image provides another instance where the topography of the upper floor material affects the winds and dune formation. At the edges of the dune field, the dunes become smaller and more separated, revealing the harder surface that the dunes are moving across. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 57843 Latitude: -43.3482 Longitude: 34.6454 Instrument: VIS Captured: 2014-12-28 12:37 https://photojournal.jpl.nasa.gov/catalog/PIA22143
Investigating Mars: Rabe Crater
2017-12-12
In this VIS image of the floor of Rabe Crater the step down into the pit is visible in the sinuous ridges on the left side of the image. The appearance of the exposed side of the cliffs does not look like a volcanic, difficult to erode material, but rather an easy to erode material such as layered sediments. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 34456 Latitude: -43.7164 Longitude: 34.4056 Instrument: VIS Captured: 2009-09-20 09:38 https://photojournal.jpl.nasa.gov/catalog/PIA22140
Evaporation components of a boreal forest: variations during the growing season
NASA Astrophysics Data System (ADS)
Grelle, A.; Lundberg, A.; Lindroth, A.; Morén, A.-S.; Cienciala, E.
1997-10-01
To improve the understanding of interactions between the boreal forest and the climate system as a key issue for global climate change, the water budget of a mixed pine and spruce forest in central Sweden was estimated by measurements of the water flux components and the total evaporation flux during the period 16 May-31 October 1995. Total evaporation was measured using eddy correlation and the components were obtained using measurements of precipitation, throughfall, tree transpiration, and forest floor evaporation. On a daily basis, tree transpiration was the dominant evaporation component during the vegetation period. However, it could be efficiently blocked by a wet canopy associated with large interception evaporation. The accumulated total evaporation was 399 mm, transpiration was 243 mm, forest floor evaporation was 56 mm and interception evaporation was 74 mm. The accumulated sum of interception, transpiration, and floor evaporation was 51 mm larger than the actual measured total evaporation. This difference was mainly attributed to the fact that transpiration was measured in a rather dense 50-year-old stand while total evaporation represented the average conditions of older, roughly 100-year-old stands. To compare eddy-correlation measurements with small-scale measurements of evaporation components, a source area analysis was made to select the flux data that give the best representation of the investigated stand. Especially under stable atmospheric conditions the requirements for surface homogeneity were very high and extreme care had to be taken to be aware of the flux source areas. Canopy water storage was determined by two methods: by the water balance of the canopy, which gave a result of 3.3 mm; and by the so-called minimum method based on plots of throughfall versus precipitation, which gave a much lower value of 1.5 mm. Seasonal interception evaporation constituted 30% of the precipitation.
13. Second Floor of c. 1900 side ell addition. View ...
13. Second Floor of c. 1900 side ell addition. View looking from the center of the automobile storage area toward the north east rear corner. - Vaughn Chevrolet Building, 101-109 East Main Street, Monongahela, Washington County, PA
12. First Floor of c. 1900 side ell addition. View ...
12. First Floor of c. 1900 side ell addition. View looking from the center of the automobile show room area toward the east side elevation. - Vaughn Chevrolet Building, 101-109 East Main Street, Monongahela, Washington County, PA
8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND ...
8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND STORAGE MAGAZINES AND LAUNCHER-LOADER ASSEMBLIES. - NIKE Missile Base SL-40, Underground Storage Magazines & Launcher-Loader Assemblies, Southwesternmost end of launch area, Hecker, Monroe County, IL
McMullen, K.Y.; Poppe, L.J.; Haupt, T.A.; Crocker, J.M.
2009-01-01
The U.S. Geological Survey (USGS) and National Oceanic and Atmospheric Administration (NOAA) have been working together to interpret sea-floor geology along the northeastern coast of the United States. In 2004, the NOAA Ship RUDE completed survey H11322, a sidescan-sonar and bathymetric survey that covers about 60 square kilometers of the sea floor in western Rhode Island Sound. This report interprets sidescan-sonar and bathymetric data from NOAA survey H11322 to delineate sea-floor features and sedimentary environments in the study area. Paleozoic bedrock and Cretaceous Coastal Plain sediments in Rhode Island Sound underlie Pleistocene glacial drift that affects the distribution of surficial Holocene marine and transgressional sediments. The study area has three bathymetric highs separated by a channel system. Features and patterns in the sidescan-sonar imagery include low, moderate, and high backscatter; sand waves; scarps; erosional outliers; boulders; trawl marks; and dredge spoils. Four sedimentary environments in the study area, based on backscatter and bathymetric features, include those characterized by erosion or nondeposition, coarse-grained bedload transport, sorting and reworking, and deposition. Environments characterized by erosion or nondeposition and coarse-grained bedload transport are located in shallower areas and environments characterized by deposition are located in deeper areas; environments characterized by sorting and reworking processes are generally located at moderate depths.
Haavik, Heidi; Murphy, Bernadette A; Kruger, Jennifer
2016-06-01
The aim of this study was to investigate whether a single session of spinal manipulation of pregnant women can alter pelvic floor muscle function as measured using ultrasonographic imaging. In this preliminary, prospective, comparative study, transperineal ultrasonographic imaging was used to assess pelvic floor anatomy and function in 11 primigravid women in their second trimester recruited via notice boards at obstetric caregivers, pregnancy keep-fit classes, and word of mouth and 15 nulliparous women recruited from a convenience sample of female students at the New Zealand College of Chiropractic. Following bladder voiding, 3-/4-dimensional transperineal ultrasonography was performed on all participants in the supine position. Levator hiatal area measurements at rest, on maximal pelvic floor contraction, and during maximum Valsalva maneuver were collected before and after either spinal manipulation or a control intervention. Levator hiatal area at rest increased significantly (P < .05) after spinal manipulation in the pregnant women, with no change postmanipulation in the nonpregnant women at rest or in any of the other measured parameters. Spinal manipulation of pregnant women in their second trimester increased the levator hiatal area at rest and thus appears to relax the pelvic floor muscles. This did not occur in the nonpregnant control participants, suggesting that it may be pregnancy related. Copyright © 2016. Published by Elsevier Inc.
TRITIUM LABORATORY, TRA666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT ...
TRITIUM LABORATORY, TRA-666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT CENTER OF VIEW. SIGN ABOVE DOOR SAYS "HYDRAULIC TEST FACILITY CONTROL ROOM." SIGN IN WINDOW SAYS "EATING AREA." "EVACUATION AND EMERGENCY INFORMATION" IS POSTED ON CABINET AT LEFT OF VIEW. INL NEGATIVE NO. HD30-2-3. Mike Crane, Photographer, 6/2001 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Dobbler, Priscila Caroline Thiago; Laureano, Álvaro Macedo; Sarzi, Deise Schroder; Cañón, Ehidy Rocio Peña; Metz, Geferson Fernando; de Freitas, Anderson Santos; Takagaki, Beatriz Midori; D Oliveira, Cristiane Barbosa; Pylro, Victor Satler; Copetti, André Carlos; Victoria, Filipe; Redmile-Gordon, Marc; Morais, Daniel Kumazawa; Roesch, Luiz Fernando Wurdig
2018-04-01
Humans distribute a wide range of microorganisms around building interiors, and some of these are potentially pathogenic. Recent research established that humans are the main drivers of the indoor microbiome and up to now significant literature has been produced about this topic. Here we analyzed differences in bacterial composition between men's and women's restrooms and other common areas within the same public building. Bacterial DNA samples were collected from restrooms and halls of a three-floor building from the Federal University of Pampa, RS, Brazil. The bacterial community was characterized by amplification of the V4 region of the 16S rRNA gene and sequencing. Throughout all samples, the most abundant phylum was Proteobacteria, followed by Actinobacteria, Bacteroidetes and Firmicutes. Beta diversity metrics showed that the structure of the bacterial communities were different among the areas and floors tested, however, only 6-9% of the variation in bacterial communities was explained by the area and floors sampled. A few microorganisms showed significantly differential abundance between men's and women's restrooms, but in general, the bacterial communities from both places were very similar. Finally, significant differences among the microbial community profile from different floors were reported, suggesting that the type of use and occupant demographic within the building may directly influence bacterial dispersion and establishment.
Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?
Stella, Judith; Hurt, Moriah; Bauer, Amy; Gomes, Paulo; Ruple, Audrey; Beck, Alan; Croney, Candace
2018-04-21
Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli . Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated.
McMullen, Katherine Y.; Poppe, Lawrence J.; Twomey, Erin R.; Danforth, William W.; Haupt, Todd A.; Crocker, James M.
2007-01-01
The U.S. Geological Survey (USGS) is working with the National Oceanic and Atmospheric Administration (NOAA) to interpret the surficial geology in estuaries and sounds along the northeastern coast of the United States. This report interprets the area covered by NOAA Survey H11320, about 72 km² of sea floor in eastern Rhode Island Sound (RIS), located about 8 km south of Sakonnet Point, Rhode Island (fig. 1). Previous work in RIS includes studies of both sea-floor processes and subsurface geologic framework. McMaster (1960) mapped surficial sediment samples in Narragansett Bay and RIS and McMaster and others (1968) conducted a seismic-reflection survey in Block Island Sound and RIS. O'Hara and Oldale (1980) collected seismic-reflection profiles, sidescan-sonar data, and vibracores in eastern RIS (fig. 2). They interpreted the geologic history, assessed sand and gravel resources, and evaluated the mining impact of these resources. McMaster's (1960) interpretation of the surficial sediment within this study area consisted of sand with several isolated areas of gravel. Several other sediment samples were previously obtained within the study area: three National Oceanographic Data Center (NODC) dredge samples from 1942 consisted of sand and one National Ocean Service (NOS) sample from 1939 was rocky (fig. 2; Poppe and others, 2003). The purpose of this report is to define the sea-floor morphology and sedimentary environments and interpret processes occurring on the sea floor using sidescan-sonar imagery, multibeam bathymetry, and historic seismic-reflection profiles.
Physical and chemical test results of electrostatic safe flooring materials
NASA Technical Reports Server (NTRS)
Gompf, R. H.
1988-01-01
This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.
13. Architectural First Floor Plan Buildings 185189 D, U.S. Atomic ...
13. Architectural First Floor Plan Buildings 185-189 D, U.S. Atomic Energy Commission, General Electric Company, Dwg. NO. H-1-11825, 1959. - D-Reactor Complex, Deaeration Plant-Refrigeration Buildings, Area 100-D, Richland, Benton County, WA
12. Architectural Floor Plans, 233S, U.S. Atomic Energy Commission, Hanford ...
12. Architectural Floor Plans, 233-S, U.S. Atomic Energy Commission, Hanford Atomic Products Operations, General Electric Company, Dwg. H-2-30464, 1956. - Reduction-Oxidation Complex, Plutonium Concentration Facility, 200 West Area, Richland, Benton County, WA
25. CAFETERIA Note remains of tile floor in foreground. Food ...
25. CAFETERIA Note remains of tile floor in foreground. Food cooked on the stove was served to workers in the eating area to the left of the counter (off picture). - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA
10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal ...
10. Floor Layout of Thermal Hydraulics Laboratory, from The Thermal Hydraulics Laboratory at Hanford. General Electric Company, Hanford Atomic Products Operation, Richland, Washington, 1961. - D-Reactor Complex, Deaeration Plant-Refrigeration Buildings, Area 100-D, Richland, Benton County, WA
PLANING MILL, FIRST FLOOR INTERIOR, LOOKING SOUTH. THE LARGE DEVICE ...
PLANING MILL, FIRST FLOOR INTERIOR, LOOKING SOUTH. THE LARGE DEVICE IS A WHEEL BORING MACHINE USED DURING THE TIME THIS AREA WAS A WHEEL SHOP. - Southern Pacific, Sacramento Shops, Planing Mill, 111 I Street, Sacramento, Sacramento County, CA
Performance Support on the Shop Floor.
ERIC Educational Resources Information Center
Kasvi, Jyrki J. J.; Vartiainen, Matti
2000-01-01
Discussion of performance support on the shop floor highlights four support systems for assembly lines that incorporate personal computer workstations in local area networks and use multimedia documents. Considers new customer-focused production paradigms; organizational learning; knowledge development; and electronic performance support systems…
39. VIEW TO NORTHEAST; WEST FRONT MBE BUILDING, FIRST FLOOR, ...
39. VIEW TO NORTHEAST; WEST FRONT MBE BUILDING, FIRST FLOOR, FRED HARVEY NEWSSTAND STOREROOM (AREA BURNED BY VANDALS) (Dobson) - Los Angeles Union Passenger Terminal, Mail, Baggage, & Express Building, 800 North Alameda Street, Los Angeles, Los Angeles County, CA
ETR, TRA642 AND TRA647. FLOOR PLANS FOR FIRST AND SECOND ...
ETR, TRA-642 AND TRA-647. FLOOR PLANS FOR FIRST AND SECOND FLOORS OF THE OFFICE AND CONTROL BUILDING ALONG THE NORTH WALL OF THE ETR BUILDING. HEALTH PHYSICS, OPERATIONS, AND CONTROL ROOM. AIRLOCK DOOR. OFFICES. STAIRWAY LOCATIONS. KAISER ETR-5528-MTR-642-A-3, 10/1955. INL INDEX NO. 532-0642-00-100911, REV. 0. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. FLOOR AND ROOF PLANS FOR SECOND ...
PROCESS WATER BUILDING, TRA-605. FLOOR AND ROOF PLANS FOR SECOND FLOOR. DETAILS OF CONCRETE ROOF SLABS. FLASH EVAPORATOR SUPPORTS AND PIPE OPENINGS TO TANKS BELOW. NOTE SPECIFIES THAT EQUIPMENT IS TO BE INSTALLED BEFORE ERECTION OF ROOF AND WALLS. BLAW-KNOX 3150-805-4, 1/1951. INL INDEX NO. 531-0605-62-098-100660, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, NORTH HALF. CAMERA IS ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, NORTH HALF. CAMERA IS NEAR NORTHWEST CORNER AND FACING SOUTH ALONG WEST CORRIDOR. STORAGE CANAL IS ALONG LEFT OF VIEW; PERIMETER WALL, ALONG RIGHT. CORRIDOR WAS ONE MEANS OF WALKING FROM NORTH TO SOUTH SIDE OF CONSOLE FLOOR. INL NEGATIVE NO. HD46-18-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Maps showing late Pleistocene and Holocene evolution of the South Texas continental shelf
Pyle, Carroll A.; Berryhill, Henry L.; Trippet, Anita R.
1979-01-01
Interpretation of acoustical profiles has provided insight into the late Quaternary geologic history of the Continental Shelf off South Texas. (See the geographic index map on sheet 1 for location of the area studied.) The profiles reveal the interplay of tectonism, sedimentation, and cyclic fluctuations of sea level in the building and geologic evolution of the continental terrace. The sequence of sediments studied extends to about 200 meters (m) beneath the sea-floor surface. Four seismic-stratigraphic units underlain by four prominent sound reflectors were identified and mapped. This geologic synthesis, for which the research was funded by the U.S. Bureau of Land Management (BLM), is but one aspect of a coordinated, multidisciplinary environmental study of the South Texas Outer Continental Shelf sponsored by BLM (Berryhill, 1976, 1977). The environmental studies are keyed to the leasing of Federal Outer Continental Shelf (OCS) lands for petroleum exploration and production. Their purpose is to provide the data development of petroleum resources on the OCS, as well as to provide the basis for predicting the impact of oil and gas exploration and production on the marine environment. Of primary concern is the recognition of geologic conditions that might be hazardous to structures placed on the sea floor. Geologic hazards relate directly to the potential for significant movement of the sea floor in the future. Judging sea-floor stability and recognizing geologic features that are potentially hazardous require an understanding of the recent geologic history of the area, which, in turn, entails determining the relative rates and interactions of sedimentation and tectonism through time. In addition to the primary objective, the synthesis provides knowledge about the magnitude and extent of sea-level fluctuations in the western Gulf of Mexico, and it provides a depositional facies model of possible use in appraising the resource potential of the more deeply buried sediments.
Impact of the buildings areas on the fire incidence.
Srekl, Jože; Golob, Janvit
2010-03-01
A survey of statistical studies shows that probability of fires is expressed by the equation P(A) = KAα, where A = total floor area of the building and K and are constants for an individual group, or risk category. This equation, which is based on the statistical data on fires in Great Britain, does not include the impact factors such as the number of employees and the activities carried out in these buildings. In order to find out possible correlations between the activities carried out in buildings, the characteristics of buildings and number of fires, we used a random sample which included 134 buildings as industrial objects, hotels, restaurants, warehouses and shopping malls. Our study shows that the floor area of buildings has low impact on the incidence of fires. After analysing the sample of buildings by using multivariate analysis we proved a correlation between the number of fires, floor area of objects, work operation period (per day) and the number of employees in objects.
14. Building 105, Facilities Engineering Building, 1830, interior, 1st floor, ...
14. Building 105, Facilities Engineering Building, 1830, interior, 1st floor, crib area of building, showing electrical and plumbing cribs, wall and ceiling detail, looking S. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
SPERTI Control Building (PER601) floor plan. Detail of cable inlet. ...
SPERT-I Control Building (PER-601) floor plan. Detail of cable inlet. Idaho Operations Office. Date: February 1955. INEEL index no. 760-0601-00-396-109139 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Exum, Natalie G; Olórtegui, Maribel Paredes; Yori, Pablo Peñataro; Davis, Meghan F; Heaney, Christopher D; Kosek, Margaret; Schwab, Kellogg J
2016-07-19
Over two billion people worldwide lack access to an improved sanitation facility that adequately retains or treats feces. This results in the potential for fecal material containing enteric pathogens to contaminate the environment, including household floors. This study aimed to assess how floor type and sanitation practices impacted the concentration of fecal contamination on household floors. We sampled 189 floor surfaces within 63 households in a peri-urban community in Iquitos, Peru. All samples were analyzed for colony forming units (CFUs) of E. coli, and households were evaluated for their water, sanitation, and hygiene characteristics. Results of multivariate linear regression indicated that households with improved sanitation and cement floors in the kitchen area had reduced fecal contamination to those with unimproved sanitation and dirt floors (Beta: -1.18 log10 E. coli CFU/900 cm(2); 95% confidence interval [CI]: -1.77, -0.60). Households that did not versus did share their sanitation facility also had less contaminated kitchen floors (Beta: -0.65 log10 E. coli CFU/900 cm(2); 95% CI: -1.15, -0.16). These findings suggest that the sanitation facilities of a home may impact the microbial load found on floors, contributing to the potential for household floors to serve as an indirect route of fecal pathogen transmission to children.
7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. ...
7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. OC1-59-53; Drawing No. 5841-A-1; D.O. SERIES AW1525/2 Rev. B. Stamped: RECORD DRAWING AS CONSTRUCTED. Below stamp: Contract No. 5619, Rev. B. Date: 7-8-59. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room
NASA Technical Reports Server (NTRS)
2005-01-01
NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.
Stalder, Claudio; Rüggeberg, Andres; Neururer, Christoph; Spangenberg, Jorge E.; Spezzaferri, Silvia
2018-01-01
The marine environment in the Gulf of Gabes (southern Tunisia) is severely impacted by phosphate industries. Nowadays, three localities, Sfax, Skhira and Gabes produce phosphoric acid along the coasts of this Gulf and generate a large amount of phosphogypsum as a waste product. The Gabes phosphate industry is the major cause of pollution in the Gulf because most of the waste is directly discharged into the sea without preliminary treatment. This study investigates the marine environment in the proximity of the phosphate industries of Gabes and the coastal marine environment on the eastern coast of Djerba, without phosphate industry. This site can be considered as "pristine" and enables a direct comparison between polluted and “clean” adjacent areas. Phosphorous, by sequential extractions (SEDEX), Rock-Eval, C, H, N elemental analysis, and stable carbon isotope composition of sedimentary organic matter, X-ray diffraction (qualitative and quantitative analysis) were measured on sediments. Temperature, pH and dissolved oxygen were measured on the water close to the sea floor of each station to estimate environmental conditions. These analyses are coupled with video surveys of the sea floor. This study reveals clear differentiations in pollution and eutrophication in the investigated areas. PMID:29771969
Leclercq, S; Saulnier, H
2001-01-01
Slips contribute to 12% of occupational accidents. A slip resistant floor is a mean to prevent slipping accidents occurring in workshops. Floor slip resistance is often evaluated by measuring a friction index, proportional to the force opposing slipping of a reference elastomer on the floor surface under test. When implementing a portable appliance, slip resistance measurements carried out on lubricated floors were not stabilized. The authors advanced the hypothesis of oil impregnating the elastomer. A new elastomer suited to in-situ measurement has been developed to achieve stable measuring conditions. This study highlights the fact that the nature and characteristics of a reference elastomer must be specified when slip resistance measurements are carried out.
31. View of mezzanine floor level in transmitter building no. ...
31. View of mezzanine floor level in transmitter building no. 102 showing various electronic central indicator panel to control building air conditioning, steam pressure, supply temperature, discharge temperature, supply pressure, transformer vault status, and radome conditioning system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK
Lunar and Venusian radar bright rings
NASA Technical Reports Server (NTRS)
Thompson, T. W.; Saunders, R. S.; Weissman, D. E.
1986-01-01
Twenty-one lunar craters have radar bright ring appearances which are analogous to eleven complete ring features in the earth-based 12.5 cm observations of Venus. Radar ring diameters and widths for the lunar and Venusian features overlap for sizes from 45 to 100 km. Radar bright areas for the lunar craters are associated with the slopes of the inner and outer rim walls, while level crater floors and level ejecta fields beyond the raised portion of the rim have average radar backscatter. It is proposed that the radar bright areas of the Venusian rings are also associated with the slopes on the rims of craters. The lunar craters have evolved to radar bright rings via mass wasting of crater rim walls and via post-impact flooding of crater floors. Aeolian deposits of fine-grained material on Venusian crater floors may produce radar scattering effects similar to lunar crater floor flooding. These Venusian aeolian deposits may preferentially cover blocky crater floors producing a radar bright ring appearance. It is proposed that the Venusian features with complete bright ring appearances and sizes less than 100 km are impact craters. They have the same sizes as lunar craters and could have evolved to radar bright rings via analogous surface processes.
The Penn State Safety Floor: Part I--Design parameters associated with walking deflections.
Casalena, J A; Ovaert, T C; Cavanagh, P R; Streit, D A
1998-08-01
A new flooring system has been developed to reduce peak impact forces to the hips when humans fall. The new safety floor is designed to remain relatively rigid under normal walking conditions, but to deform elastically when impacted during a fall. Design objectives included minimizing peak force experienced by the femur during a fall-induced impact, while maintaining a maximum of 2 mm of floor deflection during walking. Finite Element Models (FEMs) were developed to capture the complex dynamics of impact response between two deformable bodies. Validation of the finite element models included analytical calculations of theoretical buckling column response, experimental quasi-static loading of full-scale flooring prototypes, and flooring response during walking trials. Finite Element Method results compared well with theoretical and experimental data. Both finite element and experimental data suggest that the proposed safety floor can effectively meet the design goal of 2 mm maximum deflection during walking, while effectively reducing impact forces during a fall.
Case Study of Envelope Sealing in Existing Multiunit Structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Podorson, D.
2012-10-01
Envelope air sealing was included in the retrofit of a 244 unit low-rise multifamily housing complex in Durham, N.C. Pre- and post-retrofit enclosure leakage tests were conducted on 51 units and detailed diagnostics were performed on 16. On average, total leakage was reduced by nearly half, from 19.7 ACH50 to 9.4 ACH50. Costs for air sealing were $0.31 per square foot of conditioned floor area, lower than estimates found in the National Residential Efficiency Measures Database (NREMD) and other sources, perhaps due in part to the large-scale production nature of the project. Modeling with BEopt software -- using an estimatemore » of 85% of the envelope air leakage going to the outside (based on guarded tests performed at the site) -- calculated a space conditioning energy cost savings of 15% to 21% due to the air sealing retrofit. Important air leakage locations identified included plumbing and electrical penetrations, dropped ceilings/soffits, windows, ducts and wall-to-floor intersections. Previous repair activity had created significant leakage locations as well. Specifications and a pictorial guide were developed for contractors performing the work.« less
Randy Kolka; Brian Sturtevant; Philip Townsend; Jessica Miesel; Peter Wolter; Shawn Fraver; Tom DeSutter
2014-01-01
Forest fires are important contributors of C, N, and Hg to the atmosphere. In the fall of 2011, a large wildfire occurred in northern Minnesota and we were able to quickly access the area to sample the forest floor and mineral soil for C, N, and Hg pools. When compared with unburned reference soils, the mean loss of C resulting from fire in the forest floor and the...
Toward Autonomous Multi-floor Exploration: Ascending Stairway Localization and Modeling
2013-03-01
robots have traditionally been restricted to single floors of a building or outdoor areas free of abrupt elevation changes such as curbs and stairs ...solution to this problem and is motivated by the rich potential of an autonomous ground robot that can climb stairs while exploring a multi-floor...parameters of the stairways, the robot could plan a path that traverses the stairs in order to explore the frontier at other elevations that were previously
16. SECOND FLOOR RCA COMMUNICATION RECEIVING STATION FORMERLY THE POINTTOPOINT ...
16. SECOND FLOOR RCA COMMUNICATION RECEIVING STATION FORMERLY THE POINT-TO-POINT RECEIVERS WERE LOCATED HERE. (SOUTHEAST ARCHIVAL PHOTOS AND RCA LOGO ON FLOOR AS A REFERENCE). DURING THE LAST PHASE OF THE RCA ERA AND DURING GENERAL ELECTRIC-AMERITRON OWNERSHIP THIS ROOM HOUSED SATELLITE OPERATING EQUIPMENT. WHEN BOUGHT BY MCI EQUIPMENT (HI TECH) WAS REMOVED. AREA IS NOW USED FOR NATIONAL PARK SERVICE LAW ENFORCEMENT PERSONNEL. - Marconi Radio Sites, Receiving, Point Reyes Station, Marin County, CA
18. VIEW OF THE CEILING, THE PIPING TRANSPORTED CHEMICALS FROM ...
18. VIEW OF THE CEILING, THE PIPING TRANSPORTED CHEMICALS FROM A CHEMICAL PREPARATION ROOM ON THE SECOND FLOOR TO THE FIRST FLOOR PROCESS AREAS. (6/12/73) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
ERIC Educational Resources Information Center
Knuffman, Susan M.
1997-01-01
Explores ways of maintaining school floors and carpeting that ensure students and staff are comfortable, safe, and healthy. Carpet maintenance for high- to low-traffic areas and cleaning procedures are examined, as are ways maintenance staff can work together to help ensure a successful flooring-maintenance plan. (GR)
Quantifying macropore recharge: Examples from a semi-arid area
Wood, W.W.; Rainwater, Ken A.; Thompson, D.B.
1997-01-01
The purpose of this paper is to illustrate the significantly increased resolution of determining macropore recharge by combining physical, chemical, and isotopic methods of analysis. Techniques for quantifying macropore recharge were developed for both small-scale (1 to 10 km2) and regional-scale areas in and semi-arid areas. The Southern High Plains region of Texas and New Mexico was used as a representative field site to test these methods. Macropore recharge in small-scale areas is considered to be the difference between total recharge through floors of topographically dosed basins and interstitial recharge through the same area. On the regional scale, macropore recharge was considered to be the difference between regional average annual recharge and interstitial recharge measured in the unsaturated zone. Stable isotopic composition of ground water and precipitation was used us an independent estimate of macropore recharge on the regional scale. Results of this analysis suggest that in the Southern High Plains recharge flux through macropores is between 60 and 80 percent of the total 11 mm/y. Between 15 and 35 percent of the recharge occurs by interstitial recharge through the basin floors. Approximately 5 percent of the total recharge occurs as either interstitial or matrix recharge between the basin floors, representing approximately 95 percent of the area. The approach is applicable to other arid and semi-arid areas that focus rainfall into depressions or valleys.The purpose of this paper is to illustrate the significantly increased resolution of determining macropore recharge by combining physical, chemical, and isotopic methods of analysis. Techniques for quantifying macropore recharge were developed for both small-scale (1 to 10 km2) and regional-scale areas in arid and semi-arid areas. The Southern High Plains region of Texas and New Mexico was used as a representative field site to test these methods. Macropore recharge in small-scale areas is considered to be the difference between total recharge through floors of topographically closed basins and interstitial recharge through the same area. On the regional scale, macropore recharge was considered to be the difference between regional average annual recharge and interstitial recharge measured in the unsaturated zone. Stable isotopic composition of ground water and precipitation was used as an independent estimate of macropore recharge on the regional scale. Results of this analysis suggest that in the Southern High Plains recharge flux through macropores is between 60 and 80 percent of the total 11 mm/y. Between 15 and 35 percent of the recharge occurs by interstitial recharge through the basin floors. Approximately 5 percent of the total recharge occurs as either interstitial or matrix recharge between the basin floors, representing approximately 95 percent of the area. The approach is applicable to other arid and semi-arid areas that focus rainfall into depressions or valleys.
On the Biomechanics of Vaginal Birth and Common Sequelae
Ashton-Miller, James A.; DeLancey, John O.L.
2010-01-01
Approximately 11% of U.S. women undergo surgery for pelvic floor dysfunction, including genital organ prolapse and urinary and fecal incontinence. The major risk factor for developing these conditions is giving vaginal birth. Vaginal birth is a remarkable event about which little is known from a biomechanical perspective. We first review the functional anatomy of the female pelvic floor, the normal loads acting on the pelvic floor in activities of daily living, and the functional capacity of the pelvic floor muscles. Computer models show that the stretch ratio in the pelvic floor muscles can reach an extraordinary 3.26 by the end of the second stage of labor. Magnetic resonance images provide evidence that show that the pelvic floor regions experiencing the most stretch are at the greatest risk for injury, especially in forceps deliveries. A conceptual model suggests how these injuries may lead to the most common form of pelvic organ prolapse, a cystocele. PMID:19591614
Mapping the Sea Floor of the Historic Area Remediation Site (HARS) Offshore of New York City
Butman, Bradford
2002-01-01
The area offshore of New York City has been used for the disposal of dredged material for over a century. The area has also been used for the disposal of other materials such as acid waste, industrial waste, municipal sewage sludge, cellar dirt, and wood. Between 1976 and 1995, the New York Bight Dredged Material Disposal Site, also known as the Mud Dump Site (MDS), received on average about 6 million cubic yards of dredged material annually. In September 1997 the MDS was closed as a disposal site, and it and the surrounding area were designated as the Historic Area Remediation Site (HARS). The sea floor of the HARS, approximately 9 square nautical miles in area, currently is being remediated by placing a minimum 1-m-thick cap of clean dredged material on top of the surficial sediments that are contaminated from previous disposal of dredged and other materials. The U.S. Geological Survey (USGS) is working cooperatively with the U.S. Army Corps of Engineers (USACE) to map the sea floor geology of the HARS and changes in the characteristics of the surficial sediments over time.
de Araujo, Camila Carvalho; Coelho, Suelene A; Stahlschmidt, Paulo; Juliato, Cassia R T
2018-05-01
Pregnancy and delivery are well-established risk factors for pelvic floor dysfunction (PFD), but the physiopathology, such as the delivery route, is not well understood. This study evaluated the impact of delivery route on the pelvic floor muscles via 3D ultrasound. This review is registered in the PROSPERO database. The criteria for inclusion were prospective studies with 3D translabial ultrasound assessment in primigravida women during pregnancy and postpartum published in English, Spanish or Portuguese between 1980 and 2016. We excluded studies that did not include the topic of urogenital hiatus measurement and literature reviews. The MeSH terms were obstetric delivery, postpartum period, labor, parturition, three-dimensional images, ultrasonography, pelvic floor, and pelvic floor disorders. The search retrieved 155 articles. After analysis, 6 articles were included. Four studies showed that vaginal delivery (VD) was associated with a larger hiatal area. One study associated the hiatal area with levator ani muscle (LAM) defects in VD. Four articles evaluated the bladder neck, 3 of which showed a significant increase in bladder neck mobility associated with VD and 1 showed decreased bladder neck elevation, not associated with the delivery mode; the first 3 articles all evaluated LAM injuries and showed an association between VD and LAM injury. Women who underwent VD presented defects of the puborectalis muscle. Vaginal delivery was associated with a higher number of LAM injuries, puborectalis defects, increased bladder neck mobility, and enlargement of the hiatal area.
Wall-Friction Support of Vertical Loads in Submerged Sand and Gravel Columns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walton, O. R.; Vollmer, H. J.; Hepa, V. S.
Laboratory studies of the ‘floor-loads’ under submerged vertical columns of sand and/or gravel indicate that such loads can be approximated by a buoyancy-corrected Janssen-silo-theory-like relationship. Similar to conditions in storage silos filled with dry granular solids, most of the weight of the sand or gravel is supported by wall friction forces. Laboratory measurements of the loads on the floor at the base of the water-filled columns (up to 25-diameters tall) indicate that the extra floor-load from the addition of the granular solid never exceeded the load that would exist under an unsupported (wide) bed of submerged sand or gravel thatmore » has a total depth corresponding to only two column-diameters. The measured floorloads reached an asymptotic maximum value when the depth of granular material in the columns was only three or four pipe-diameters, and never increased further as the columns were filled to the top (e.g. up to heights of 10 to 25 diameters). The floor-loads were stable and remained the same for days after filling. Aggressive tapping (e.g. hitting the containing pipe on the outside, manually with a wrench up and down the height and around the circumference) could increase (and occasionally decrease) the floor load substantially, but there was no sudden collapse or slumping to a state without significant wall friction effects. Considerable effort was required, repeatedly tapping over almost the entire column wall periphery, in order to produce floor-loads that corresponded to the total buoyancy-corrected weight of granular material added to the columns. Projecting the observed laboratory behavior to field conditions would imply that a stable floor-load condition, with only a slightly higher total floor pressure than the preexisting hydrostatic-head, would exist after a water-filled bore-hole is filled with sand or gravel. Significant seismic vibration (either a large nearby event or many micro-seismic events over an extended period) would likely be necessary before the full (buoyancy-corrected) weight of the sand and/or gravel would be ‘delivered’ to the bottom of the submerged column.« less
SAFETY AND SECURITY BUILDING, TRA614. SIMPLIFIED FLOOR LAYOUT AND WEST ...
SAFETY AND SECURITY BUILDING, TRA-614. SIMPLIFIED FLOOR LAYOUT AND WEST ELEVATION. BLAW-KNOX 3150-14-1, 1/1950. INL INDEX NO. 531-0614-00-098-100024, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
15. View looking up Dramp from middle floor level showing ...
15. View looking up D-ramp from middle floor level showing lighting conduits and manometer panel on wall of decontamination area. Building 501, October 2, 1956 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE
78 FR 28887 - Changes in Flood Hazard Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Management Branch, Federal Insurance and Mitigation Administration, FEMA, 500 C Street SW., Washington, DC...: Bexar (FEMA Docket No.: B- Unincorporated areas The Honorable Nelson W. Bexar County Public February 19... Allen, 305 Century Department, 305 Parkway, 1st Floor, Century Parkway, Allen, TX 75013. 1st Floor...
Van Batavia, Jason P; Combs, Andrew J; Hyun, Grace; Bayer, Agnes; Medina-Kreppein, Daisy; Schlussel, Richard N; Glassberg, Kenneth I
2011-10-01
Noninvasive uroflowmetry with simultaneous electromyography is useful to triage cases of lower urinary tract symptoms into 4 urodynamically defined conditions, especially when incorporating short and long electromyography lag times in the analysis. We determined the prevalence of these 4 conditions at a single referral institution and the usefulness of uroflowmetry with simultaneous electromyography and electromyography lag time to confirm the diagnosis, guide treatment and monitor response. We retrospectively reviewed the records of 100 consecutive normal children who presented with persistent lower urinary tract symptoms, underwent uroflowmetry with electromyography as part of the initial evaluation and were diagnosed with 1 of 4 conditions based on certain uroflowmetry/electromyography features. The conditions included 1) dysfunctional voiding--active pelvic floor electromyography during voiding with or without staccato flow, 2a) idiopathic detrusor overactivity disorder-A--a quiet pelvic floor during voiding and shortened lag time (less than 2 seconds), 2b) idiopathic detrusor overactivity disorder-B--a quiet pelvic floor with a normal lag time, 3) detrusor underutilization disorder--volitionally deferred voiding with expanded bladder capacity but a quiet pelvic floor, and 4) primary bladder neck dysfunction--prolonged lag time (greater than 6 seconds) and a depressed, right shifted uroflowmetry curve with a quiet pelvic floor during voiding. Treatment was tailored to the underlying condition in each patient. The group consisted of 50 males and 50 females with a mean age of 8 years (range 3 to 18). Dysfunctional voiding was more common in females (p <0.05) while idiopathic detrusor overactivity disorder-B and primary bladder neck dysfunction were more common in males (p <0.01). With treatment uroflowmetry parameters normalized for all types. Electromyography lag time increased in idiopathic detrusor overactivity disorder-A cases and decreased in primary bladder neck dysfunction cases. Noninvasive uroflowmetry with simultaneous electromyography offers an excellent alternative to invasive urodynamics to diagnose 4 urodynamically defined conditions. It identifies the most appropriate therapy for the specific condition and objectively monitors the treatment response. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Repair Air Conditioning, COC Bldg 2605, First Floor Plan. By ...
Repair Air Conditioning, COC Bldg 2605, First Floor Plan. By Strategic Air Command, Civil Engineering. Drawing no. R-156, sheet no. 2 of 4, 15 August 1968; project no. MAR-125-8;CE-572; file drawer 2605-6. Scale one-eighth inch to one foot. 29x41 inches. pencil on paper 405 - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Effect of different flooring systems on claw conformation of dairy cows.
Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C
2009-06-01
The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and medial claws.
PUMP HOUSE FOR MTR WELL NO. 1, TRA601. FLOOR PLAN, ...
PUMP HOUSE FOR MTR WELL NO. 1, TRA-601. FLOOR PLAN, ELEVATIONS, SECTION SHOWING WELL CASING, ROOF FRAMING PLAN. AS BUILT. WELL HOUSE FOR WELL NO. 2, TRA-602, WAS IDENTICAL IN ALL PARTICULARS EXCEPT FLOOR DIMENSIONS AND ARRANGEMENT OF PUMP AND ELECTRICAL EQUIPMENT INSIDE. IDAHO OPERATIONS OFFICE MTR-601-IDO-1, 12/1954. INL INDEX NO. 531-0601-00-396-110463, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
2014-01-01
soil, etc.) (Ref 6); (b) the kinematic and structural response of the target to blast loading including the role of target design and use of blast...both the role of material behavior under transient-dynamic loading conditions as well as the kinematic and structural responses of the target structure... seats , ammunition storage racks, power-train lines, etc.). Tradition- ally, the floor-rupture problem is solved through the use of thicker floor-plates
Effect of rubber flooring on group-housed sows' gait and claw and skin lesions.
Bos, E-J; van Riet, M M J; Maes, D; Millet, S; Ampe, B; Janssens, G P J; Tuyttens, F A M
2016-05-01
This study evaluated the influence of floor type on sow welfare in terms of lameness, claw lesions, and skin lesions. In a 2 × 3 factorial design, we have investigated the effect of rubber coverings on concrete floors and the effect of 3 levels of dietary zinc supplementation on locomotion and claw and skin lesions in group-housed sows. Six groups of 21 ± 4 hybrid sows were monitored during 3 successive reproductive cycles. The sows were group housed from d 28 after insemination (d 0) until 1 wk before expected farrowing date (d 108) in pens with either exposed concrete floors or concrete floors covered with rubber in part of the lying area and the fully slatted area. During each reproductive cycle, locomotion and skin lesions were assessed 4 times (d 28, 50, 108, and 140) and claw lesions were assessed twice (d 50 and 140). Results are given as least squares means ± SE. Locomotion and claw scores were given in millimeters, on analog scales of 150 and 160 mm, respectively. Here, we report on the effect of floor type, which did not interact with dietary zinc concentration ( > 0.10 for all variables). At move to group (d 28) and mid gestation (d 50), no differences between floor treatments were seen in locomotion ( > 0.10). At the end of gestation (d 108), sows housed on rubber flooring scored 9.9 ± 4.1 mm better on gait ( < 0.001). Regarding claw disorders, both parameters "heel overgrowth and erosion" (difference of 4.6 ± 1.8 mm; = 0.01) and "heel-sole crack" (difference of 3.1 ± 1.5 mm; = 0.04) scores were better for sows on rubber flooring at mid gestation (d 50). However, sows on rubber flooring scored worse for "vertical cracks in the wall horn" (difference of 3.4 ± 1.7 mm; = 0.04). At the end of lactation (d 140), both "white line" (difference of 2.9 ± 1 mm; = 0.02) and "claw length" (difference of 4.7 ± 1.4 mm; < 0.001) had better scores on rubber flooring. No differences for skin lesions were observed between floor treatments. The improved scores for gait toward the end of gestation and some types of claw disorders at mid gestation suggest that rubber flooring in group housing has a beneficial effect on the overall leg health of sows. The documented increase in vertical cracks in the wall horn at d 50 requires further investigation.
Li, Ning; Tsushima, Eiki; Tsushima, Hitoshi
2013-04-05
Use of hip protectors and compliant flooring has been recommended for preventing hip fracture due to falls. We aimed to identify the factors attenuating forces in falls by comparing and analyzing the impact forces occurring with various combinations of hip protectors and flooring materials. We designed a simplified pendulum device to simulate the impact force at the hip during falling. The impact force was measured on pressure-sensitive recording film under combined conditions of two kinds of hip protector (hard or soft shell) and three kinds of floor material (concrete, wooden, or tatami matting). We then calculated the percentage force attenuation under each test condition compared with the use of a concrete floor and no hip protector. All the tests using tatami matting reduced the impact to below the average fracture threshold of elderly people (3472N). A combination of tatami and soft hip protector provided the best attenuation (72.5%). Multiple regression analyses showed that use of tatami matting and a soft hip protector had the biggest force-attenuation effect. The soft hip protector gave better percentage force attenuation than did the hard one. Use of tatami matting as a flooring material could be an effective strategy for helping prevent hip fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.
Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?
Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace
2018-01-01
Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated. PMID:29690514
Measurements of carbonyls in a 13-story building.
Báez, Armando P; Padilla, Hugo G; García, Rocío M; Belmont, Raúl D; Torres, Maria del Carmen B
2004-01-01
Formaldehyde and acetaldehyde are emitted by many mobile and stationary sources and secondary aldehydes are intermediates in the photo-oxidation of organic compounds in the atmosphere. These aldehydes are emitted indoors by many materials such as furniture, carpets, heating and cooling systems, an by smoking. Carbonyls, mainly formaldehyde and acetaldehyde, have been studied because of their adverse health effects. In addition, formaldehyde is a suspected carcinogen. Therefore, the concentrations of formaldehyde and acetaldehyde were determined to assess the inhalation exposure doses to carbonyls for people who work in a 13-story building and in order to evaluate the cancer hazard. Carbonyl compounds in indoor and outdoor air were measured at a 13-story building located in Mexico City. The mezzanine, fifth and tenth floors, and the third level-parking garage were selected for sampling. Samples were collected in two sampling periods, the first from April 20 to 29, 1998 and the second from December 1 to 20, 1998. Carbonyls were sampled by means of DNHP-coated cartridges at a flow rate of 1 l min(-1) from 9:00 to 19:00 hours, during 2-hour time intervals and analyzed by HPLC with hours, during 2-hour time intervals and analyzed by HPLC with UV/VIS detection. Mean carbonyl concentrations were highest in the 3rd level-parking garage, with the formaldehyde concentration being the highest ranging from 108 to 418 microg m(-3). In working areas, the highest carbonyl arithmetic mean concentrations (AM) were observed on the 5th floor. Acetone and formaldehyde concentrations were highest in April ranging from 161 to 348 microg m(-3) (AM = 226) and from 157 to 270 microg m(-3) (AM = 221), respectively. Propionaldehyde and butyraldehyde were present in smaller concentrations ranging from 2 to 25 and 1 to 28 microg m(-3), respectively, considering all the samples. Mean indoor/outdoor ratios of carbonyls ranged from 1.8 to 9.6. A reduction of inhalation exposure doses of 41% and 45% was observed in the fifth floor air after the air conditioning systems had been repaired. Formaldehyde and acetaldehyde concentrations were higher in smoking environments. Indoor carbonyl concentrations were significantly greater than outdoor concentrations. Tobacco smoke seems to be the main indoor source of formaldehyde. After the air conditioning system was maintained and repaired (as was recommended), an important reduction in the emission of formaldehyde and acetaldehyde was achieved on all floors, except for the 3rd level parking garage, thereby reducing the inhalation exposure doses. The results obtained in this research demonstrated that maintenance of air conditioning systems must be carried out regularly in order to avoid possible adverse effects on health. Additionally, it is mandatory that isolated smoking areas, with air extraction systems, be installed in every public building.
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2016-09-01
The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.
One corner of the third floor has examples of Edison ...
One corner of the third floor has examples of Edison motion picture projectors in rather poor condition. Better preserved examples are in storage in Vault #12. - Thomas A. Edison Laboratories, Building No. 5, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
Rao, Anantheswar Y. N.
2015-01-01
Midline cleft of the lower lip and mandible is an extremely rare condition. Since 1819, when the first case was reported by Couronne, fewer than 80 cases have been described in the world literature so far. The cleft has also been described as facial cleft no. 30 by Paul Tessier. The condition varies in severity from a mild variety in which there is a submucous cleft and notching in the lower lip to a severe variety, involving the tongue, floor of the mouth, mandible, absent hyoid, atrophic neck muscles, and sternum. In this case report, a female child having complete midline cleft of the lower lip and mandible, with bifid tongue stuck to the floor of the mouth, absent hyoid bone and flexion contracture band extending from the confluence of the tip of the tongue, floor of the mouth, cleft mandible to the manubrium sterni is described, with special emphasis on surgical planning and management. PMID:26576245
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. CAMERA FACING SOUTH INTO ETR ELECTRICAL BUILDING (TRA-648). INL NEGATIVE NO. HD46-20-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Urban Fire Simulation. Version 2
1993-02-01
of the building. In this case the distribution of windows in the tract per floor ( DWPF (FLOORHT)) is calculated under the assumption that the number of...given urban area. The probability that no room on the subject floor will flash over is calculated at label (V) from PNRFOF DWPF (FLOORHT) (1 - FFORF
36 CFR 28.12 - Development standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... unless it complies with the following: (a) A single-family home is the only type of development permitted... accessory structures on the property and any extension of the upper floors beyond the developed area on the... and accessory structures on the property and any extension of the upper floors beyond the developed...
6. PERSPECTIVE VIEW TO SOUTHWEST SHOWING NORTHWEST CORNER OF ASSEMBLY ...
6. PERSPECTIVE VIEW TO SOUTHWEST SHOWING NORTHWEST CORNER OF ASSEMBLY BUILDING WHERE SHOWROOMS (FIRST FLOOR) AND OFFICES (SECOND FLOOR) WERE LOCATED. WEST SIDE OF ASSEMBLY AREA IS TO RIGHT. - Rosie the Riveter National Historical Park, Ford Assembly Plant, 1400 Harbour Way South, Richmond, Contra Costa County, CA
8. VIEW TO EAST SHOWING PORTION OF WEST ELEVATION OF ...
8. VIEW TO EAST SHOWING PORTION OF WEST ELEVATION OF ASSEMBLY AREA. MAIN ASSEMBLY LINE RAN FROM RIGHT TO LEFT ALONG THE FIRST-FLOOR WINDOWS. PARTS STORAGE WAS ON SECOND FLOOR. - Rosie the Riveter National Historical Park, Ford Assembly Plant, 1400 Harbour Way South, Richmond, Contra Costa County, CA
36 CFR 28.23 - Certificates of suspension of authority for acquisition by condemnation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... developed area on the ground level; (2) On the survey, the line of mean high water, the toe of the dune, and the crest of the dune shall be identified if they traverse the lot; (3) A floor plan of each floor of...
Matsuda, Yasunori; Sakaida, Hiroshi; Kobayashi, Masayoshi; Takeuchi, Kazuhiko
2016-10-01
Although surgical treatment of orbital floor fractures can be performed by many different approaches, the application of endoscopic modified medial maxillectomy (EMMM) for this condition has rarely been described in the literature. We report on a case of a 7-year-old boy with a trapdoor orbital floor fracture successfully treated with the application of EMMM. The patient suffered trauma to the right orbit floor and the inferior rectus was entrapped at the orbital floor. Initially, surgical repair via endoscopic endonasal approach was attempted. However, we were unable to adequately access the orbital floor through the maxillary ostium. Therefore, an alternative route of access to the orbital floor was established by EMMM. With sufficient visualization and operating space, the involved orbital content was completely released from the entrapment site and reduced into the orbit. To facilitate wound healing, the orbital floor was supported with a water-inflated urethral balloon catheter for 8 days. At follow-up 8 months later, there was no gaze restriction or complications associated with the EMMM. This case illustrates the efficacy and safety of EMMM in endoscopic endonasal repair of orbital floor fracture, particularly for cases with a narrow nasal cavity such as in pediatric patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hirayama, Hideo; Kondo, Kenjiro; Suzuki, Seishiro; Hamamoto, Shimpei; Iwanaga, Kohei
2017-09-01
Pulse height distributions were measured using a LaBr3 detector set in a 1 cm lead collimator to investigate main radiation source at the operation floor of Fukushima Daiichi Nuclear Power Station Unit 4. It was confirmed that main radiation source above the reactor well was Co-60 from the activated steam dryer in the DS pool (Dryer-Separator pool) and that at the standby area was Cs-134 and Cs-137 from contaminated buildings and debris at the lower floor. Full energy peak count rate of Co-60 was reduced about 1/3 by 12mm lead sheet placed on the floor of the fuel handling machine.
31. PETIBONE SAND THROWING MACHINE BOX FLOOR GREY IRON FOUNDRY ...
31. PETIBONE SAND THROWING MACHINE BOX FLOOR GREY IRON FOUNDRY FORCES CONDITIONED MOLDING SAND, AT HIGH VELOCITY, INTO MOLDS TOO BIG TO BE MADE ON ONE OF THE CONVEYOR SYSTEMS. - Stockham Pipe & Fittings Company, Grey Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
Arnold, W; Vosteen, K H
1979-08-01
The authors tell of their experience with the reconstruction of the floor of the mouth following surgery for cancer. They feel that especially in older patients with bad general condition the simplest surgical methods of reconstruction are the best.
Ground Penetrating Radar Investigations in the Noble Hall of São Carlos Theater in Lisbon, Portugal
NASA Astrophysics Data System (ADS)
Fontul, S.; Solla, M.; Cruz, H.; Machado, J. S.; Pajewski, L.
2018-05-01
This paper describes a study conducted by the National Laboratory for Civil Engineering of Portugal (LNEC), in cooperation with the Defense University Center at the Spanish Naval Academy and "La Sapienza," University of Rome, to assess the health and safety conditions of the Noble Hall floor in the São Carlos National Theater (Lisbon, Portugal). In a multidisciplinary approach, extensive fieldwork was carried out. The survey included the location and characterization of beams in the various areas of the floor by using two ground penetrating radar (GPR) systems equipped with two different ground- or air-coupled antennas, local inspection openings to visually assess the geometry, timber species and conservation state of structural members, and an assessment of the conservation state of the timber beam ends using drilling equipment. All the tests performed and the results obtained are presented. The potential of using non-destructive tests for the inspection of timber cultural heritage structures, particularly GPR, is discussed, and some practical recommendations are made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, D.L.; Wagner, J.B.
1988-09-01
Before siting oil and gas platforms on the sea floor as artificial reefs offshore Louisiana, potentially hazardous and unstable geologic conditions must be identified and evaluated to assess their possible impacts on platform stability. Geologic and man-made features can be identified and assessed from high-resolution geophysical techniques (3.5-7.0 kHz echograms, single-channel seismic, and side-scan sonar). Such features include faults, diapirs, scarps, channels, gas seeps, irregular sea floor topography, mass wasting deposits (slumps, slides, and debris flows), pipelines, and other subsea marine equipment. Geotechnical techniques are utilized to determine lithologic and physical properties of the sediments for correlation with the geophysicalmore » data. These techniques are used to develop a series of geologic maps, cross sections, and pipeline and platform-location maps. Construction of echo-character maps from 3.5-kHz data provides an analysis of near-bottom sedimentation processes (turbidity currents and debris flows).« less
The image acquisition system design of floor grinder
NASA Astrophysics Data System (ADS)
Wang, Yang-jiang; Liu, Wei; Liu, Hui-qin
2018-01-01
Based on linear CCD, high resolution image real-time acquisition system serves as designing a set of image acquisition system for floor grinder through the calculation of optical imaging system. The entire image acquisition system can collect images of ground before and after the work of the floor grinder, and the data is transmitted through the Bluetooth system to the computer and compared to realize real-time monitoring of its working condition. The system provides technical support for the design of unmanned ground grinders.
Network support for turn-taking in multimedia collaboration
NASA Astrophysics Data System (ADS)
Dommel, Hans-Peter; Garcia-Luna-Aceves, Jose J.
1997-01-01
The effectiveness of collaborative multimedia systems depends on the regulation of access to their shared resources, such as continuous media or instruments used concurrently by multiple parties. Existing applications use only simple protocols to mediate such resource contention. Their cooperative rules follow a strict agenda and are largely application-specific. The inherent problem of floor control lacks a systematic methodology. This paper presents a general model on floor control for correct, scalable, fine-grained and fair resource sharing that integrates user interaction with network conditions, and adaptation to various media types. The motion of turn-taking known from psycholinguistics in studies on discourse structure is adapted for this framework. Viewed as a computational analogy to speech communication, online collaboration revolves around dynamically allocated access permissions called floors. The control semantics of floors derives from concurrently control methodology. An explicit specification and verification of a novel distributed Floor Control Protocol are presented. Hosts assume sharing roles that allow for efficient dissemination of control information, agreeing on a floor holder which is granted mutually exclusive access to a resource. Performance analytic aspects of floor control protocols are also briefly discussed.
Effect of rubber flooring in front of the feed bunk on the time budgets of dairy cattle.
Fregonesi, Jose A; Tucker, Cassandra B; Weary, Daniel M; Flower, Frances C; Vittie, Tyler
2004-05-01
The objective of this experiment was to study the effect of rubber flooring in front of the feed bunk on the immediate behavioral response of dairy cattle. Four groups of 12 dairy cattle were alternately housed in sections of a free-stall barn with either 1.85 m of rubber flooring or grooved concrete in the area in front of the feed bunk. Rubber flooring did not affect time spent eating. However, animals showed a slight, but detectable, increase in time standing without eating on the rubber surface (5.5%) compared with concrete (4.8%). For reasons that are unclear, this increase in time spent standing was not limited to the area in front of the feed bunk; animals spent 11.0% of the available time standing elsewhere in the pen (outside of the free stall but not in front of the feed bunk) when they had access to the rubber flooring, compared with 9.0% when housed with access to only concrete floors. In addition, animals spent slightly less time lying in the free stall when they had access to rubber in front of the feed bunk (52.5 vs. 54.3%). Time spent engaged in behaviors such as standing elsewhere in the pen and eating were variable over time. For example, time spent eating declined from 23.1 to 17.4% over the 6-wk trial. In conclusion, dairy cattle with access to rubber flooring in front of the feeder showed small differences in where and how much time they spent standing, although the biological implications of these small changes are unclear.
Investigating Mars: Rabe Crater
2017-12-18
The majority of the dune field in Rabe Crater consists of a sand sheet with dune forms on the surface. The sand sheet is where a thick layer of sand has been concentrated. As continued winds blow across the sand surface it creates dune forms. The depth of the sand sheet prevents excavation to the crater floor and the dune forms all appear connected. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 58024 Latitude: -43.6954 Longitude: 34.8236 Instrument: VIS Captured: 2015-01-12 09:48 https://photojournal.jpl.nasa.gov/catalog/PIA22144
Investigating Mars: Rabe Crater
2017-12-21
This is a false color image of Rabe Crater. In this combination of filters "blue" typically means basaltic sand. This VIS image crosses the entire crater and demonstrates how extensive the dunes are on the floor of Rabe Crater. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The THEMIS VIS camera contains 5 filters. The data from different filters can be combined in multiple ways to create a false color image. These false color images may reveal subtle variations of the surface not easily identified in a single band image. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 67013 Latitude: -43.2572 Longitude: 34.5875 Instrument: VIS Captured: 2017-01-21 18:25 https://photojournal.jpl.nasa.gov/catalog/PIA22147
Effects of elevated CO2 and temperature on forest floor litter decomposition and chemistry
Forest floor can be a major component of the carbon held in forested soils. In mature forests it represents the balance between additions and decomposition under current climate conditions. Because of its position at the soil surface, this reservoir of C is highly susceptible...
McMullen, Katherine Y.; Poppe, Lawrence J.; Parker, Castle E.
2015-01-01
Multibeam bathymetry, collected during NOAA hydrographic surveys in 2008 and 2009, is coupled with USGS data from sampling and photographic stations to map the seabed morphology and composition of Rhode Island Sound along the US Atlantic coast, and to provide information on sediment transport and benthic habitats. Patchworks of scour depressions cover large areas on seaward-facing slopes and bathymetric highs in the sound. These depressions average 0.5-0.8 m deep and occur in water depths reaching as much as 42 m. They have relatively steep well-defined sides and coarser-grained floors, and vary strongly in shape, size, and configuration. Some individual scour depressions have apparently expanded to combine with adjacent depressions, forming larger eroded areas that commonly contain outliers of the original seafloor sediments. Where cobbles and scattered boulders are present on the depression floors, the muddy Holocene sands have been completely removed and the winnowed relict Pleistocene deposits exposed. Low tidal-current velocities and the lack of obstacle marks suggest that bidirectional tidal currents alone are not capable of forming these features. These depressions are formed and maintained under high-energy shelf conditions owing to repetitive cyclic loading imposed by high-amplitude, long-period, storm-driven waves that reduce the effective shear strength of the sediment, cause resuspension, and expose the suspended sediments to erosion by wind-driven and tidal currents. Because epifauna dominate on gravel floors of the depressions and infauna are prevalent in the finer-grained Holocene deposits, it is concluded that the resultant close juxtaposition of silty sand-, sand-, and gravel-dependent communities promotes regional faunal complexity. These findings expand on earlier interpretations, documenting how storm wave-induced scour produces sorted bedforms that control much of the benthic geologic and biologic diversity in Rhode Island Sound.
Wood, W.W.; Stokes, S.; Rich, J.
2002-01-01
Springs in the 40 to 50 large lake basins (>15 km2) on the southern portion of the Southern High Plains (SHP) were active during periods of aridity in the Holocene when there may have been human habitation of the area. Eolian erosion of the lake floors and lunette accretion occurred as groundwater levels declined in response to decreased groundwater recharge. The declining lake floor associated with eolian erosion allowed groundwater evaporative discharge to continue, thus maintaining a groundwater gradient toward the lake. This hydrologic condition was favorable for a relatively continuous spring discharge to the lake, independent of the elevation of the lake floor. To evaluate the postulated dynamic equilibrium critical to this conclusion, 17 optically stimulated ages were determined from a 17.7-m deep core of a lunette adjacent to Double Lakes, Texas (33??13???15???N, 101??54???08???W). The core yielded sediment accumulation dates of 11,500 ?? 1100, 6500 ?? 700, and 4900 ?? 500 yr B.P., corresponding broadly with periods of aridity known from other evidence. Based on analysis of this lunette, it is concluded that springs in Double Lakes basin probably existed throughout the Holocene with discharges similar to those observed historically. We assumed that similar dynamic equilibrium existed in the other large lake basins in the SHP and that these springs could have provided a continuous source of water for indigenous peoples during periods of prolonged aridity. The dynamic equilibrium that is proposed in this study is applicable not only to other arid and semiarid geographic areas with wind-erodible material but also over different geologic times. ?? 2002 University of Washington.
PROCESS WATER BUILDING, TRA605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN ...
PROCESS WATER BUILDING, TRA-605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN LEFT HALF OF VIEW. CAMERA IS IN NORTHWEST CORNER FACING SOUTHEAST. INL NEGATIVE NO. HD46-27-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG ...
ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG SOUTH PERIMETER WALL (COMMON TO ELECTRICAL BUILDING, TRA-648). CAMERA FACES WEST. INL NEGATIVE NO. HD46-16-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
31. INTERIOR VIEW TO THE EAST OF THE FIRST FLOOR ...
31. INTERIOR VIEW TO THE EAST OF THE FIRST FLOOR SOUTH CORRIDOR AND VIEWING GALLERY TO THE DISASSEMBLY BAY AND POST-MORTEM CELLS. VIEWING STATIONS ARE ON BOTH SIDES OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
SAFETY AND SECURITY BUILDING, TRA614. FLOOR, ROOF, AND FOUNDATION PLANS. ...
SAFETY AND SECURITY BUILDING, TRA-614. FLOOR, ROOF, AND FOUNDATION PLANS. ROOM FUNCTIONS. DOOR AND ROOM FINISH SCHEDULE. BLAW-KNOX 3150-814-1, 3/1950. INL INDEX NO. 531-0614-00-098-100702, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
38. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR ...
38. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR CORRIDOR ON THE SOUTH SIDE OF THE DISASSEMBLY BAY. VIEWING AND WORK STATIONS ARE ALONG THE NORTH WALL OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
LPT. EBOR (TAN646). Floor plan for new helium management wing. ...
LPT. EBOR (TAN-646). Floor plan for new helium management wing. Detail of sample vault and basement switch room. Kaiser engineers EBOR/GA-646-A-101. Date: May 1963. INEEL index code no. 037-0646-00-486-119115 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Change House (TAN606). Elevations and floor plan. Room Names. ...
ADM. Change House (TAN-606). Elevations and floor plan. Room Names. Ralph M. Parsons 902-2-ANP-606-A 65. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0606-00-693-106733 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Warehouse (TAN604) Floor plan. General warehouse and chemical storage. ...
ADM. Warehouse (TAN-604) Floor plan. General warehouse and chemical storage. Ralph M. Parsons 902-2-ANP-604-A 55. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0604-00-693-106727 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
General view of the shop floor looking north in the ...
General view of the shop floor looking north in the Vertical Processing Area of the Space Shuttle Main Engine (SSME) Processing Facility at Kennedy Space Center. SSME number 2061 is in the foreground. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
MTR WING A, TRA604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE ...
MTR WING A, TRA-604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE LABORATORY 114. CAMERA FACING NORTH. DISPOSAL OF RADIOACTIVE MATERIALS IS UNDERWAY. INL NEGATIVE NO. HD46-12-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. Technical service laboratory in administration building (TAN602). Floor plan, ...
A&M. Technical service laboratory in administration building (TAN-602). Floor plan, reception desk, door and finish schedules. Ralph M. Parsons 1480-12-ANP/GE-3-602-A-1. INEEL index code no. 033-0602-00-693-107488 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...
Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE OF ETR REACTOR, CAMERA FACING NORTH. CABINET CONTAINING "NUCLEAR INSTRUMENT SYSTEMS" IS RESTRICTED. INL NEGATIVE NO. HD46-18-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Stone Age hut in Israel yields world's oldest evidence of bedding.
Nadel, Dani; Weiss, Ehud; Simchoni, Orit; Tsatskin, Alexander; Danin, Avinoam; Kislev, Mordechai
2004-04-27
The earliest archaeological remains of dwelling huts built by Homo sapiens were found in various European Upper Paleolithic open-air camps. Although floors of huts were found in a small number of cases, modern organization of the home space that includes defined resting areas and bedding remains was not discovered. We report here the earliest in situ bedding exposed on a brush hut floor. It has recently been found at the previously submerged, excellently preserved 23,000-year-old fisher-hunter-gatherers' camp of Ohalo II, situated in Israel on the shore of the Sea of Galilee. The grass bedding consists of bunches of partially charred Puccinellia confer convoluta stems and leaves, covered by a thin compact layer of clay. It is arranged in a repeated pattern, on the floor, around a central hearth. This study describes the bedding in its original context on a well preserved intentionally constructed floor. It also reconstructs on the basis of direct evidence (combined with ethnographic analogies) the Upper Paleolithic hut as a house with three major components: a hearth, specific working locales, and a comfortable sleeping area near the walls.
Sensitization to epoxy resin systems in special flooring workers.
Condé-Salazar, L; Gonzalez de Domingo, M A; Guimaraens, D
1994-09-01
The use of new products in building and public works is increasing, among them being special floor coverings containing epoxy resins and derivatives. These are used principally in heavily frequented areas, such as shopping precincts, hospitals, civic centres, etc., due to their high resistance to wear and tear, environmental factors, etc. In the last 2 years, we have studied 15 cases of men sensitized to epoxy resin, or derivatives, who worked with special floorings. Speed of sensitization, severity of lesions, and localization to the hands, face and legs were characteristic.
Investigating Mars: Rabe Crater
2017-12-20
This is a false color image of Rabe Crater. In this combination of filters "blue" typically means basaltic sand. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The THEMIS VIS camera contains 5 filters. The data from different filters can be combined in multiple ways to create a false color image. These false color images may reveal subtle variations of the surface not easily identified in a single band image. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 52231 Latitude: -43.6665 Longitude: 34.2627 Instrument: VIS Captured: 2013-09-22 14:29 https://photojournal.jpl.nasa.gov/catalog/PIA22146
Investigating Mars: Rabe Crater
2017-12-22
This is a false color image of Rabe Crater. In this combination of filters "blue" typically means basaltic sand. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The THEMIS VIS camera contains 5 filters. The data from different filters can be combined in multiple ways to create a false color image. These false color images may reveal subtle variations of the surface not easily identified in a single band image. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 67144 Latitude: -43.5512 Longitude: 34.5951 Instrument: VIS Captured: 2017-02-01 12:57 https://photojournal.jpl.nasa.gov/catalog/PIA22148
Investigating Mars: Rabe Crater
2017-12-19
This is a false color image of Rabe Crater. In this combination of filters "blue" typically means basaltic sand. Rabe Crater is 108 km (67 miles) across. Craters of similar size often have flat floors. Rabe Crater has some areas of flat floor, but also has a large complex pit occupying a substantial part of the floor. The interior fill of the crater is thought to be layered sediments created by wind and or water action. The pit is eroded into this material. The eroded materials appear to have stayed within the crater forming a large sand sheet with surface dune forms as well as individual dunes where the crater floor is visible. The dunes also appear to be moving from the upper floor level into the pit. The THEMIS VIS camera contains 5 filters. The data from different filters can be combined in multiple ways to create a false color image. These false color images may reveal subtle variations of the surface not easily identified in a single band image. The Odyssey spacecraft has spent over 15 years in orbit around Mars, circling the planet more than 69000 times. It holds the record for longest working spacecraft at Mars. THEMIS, the IR/VIS camera system, has collected data for the entire mission and provides images covering all seasons and lighting conditions. Over the years many features of interest have received repeated imaging, building up a suite of images covering the entire feature. From the deepest chasma to the tallest volcano, individual dunes inside craters and dune fields that encircle the north pole, channels carved by water and lava, and a variety of other feature, THEMIS has imaged them all. For the next several months the image of the day will focus on the Tharsis volcanoes, the various chasmata of Valles Marineris, and the major dunes fields. We hope you enjoy these images! Orbit Number: 51157 Latitude: -43.6787 Longitude: 34.3985 Instrument: VIS Captured: 2013-06-26 05:33 https://photojournal.jpl.nasa.gov/catalog/PIA22145
Urogenital consequences in ageing women.
Doumouchtsis, Stergios K; Chrysanthopoulou, Eleftheria L
2013-10-01
Various anatomical, physiological, genetic, lifestyle and reproductive factors interact throughout a woman's life span and contribute to pelvic floor disorders. Ageing affects pelvic floor anatomy and function, which can result in a variety of disorders, such as pelvic organ prolapse, lower urinary tract symptoms, dysfunctional bowel and bladder evacuation, and sexual dysfunction. The exact mechanisms and pathophysiological processes by which ageing affects pelvic floor and lower urinary and gastrointestinal tract anatomy and function are not always clear. In most cases, it is difficult to ascertain the exact role of ageing per se as an aetiological, predisposing or contributing factor. Other conditions associated with ageing that may co-exist, such as changes in mental status, can result in different types of pelvic floor dysfunction (e.g. functional incontinence). Pelvic organ dysfunction may be associated with significant morbidity and affect quality of life. These groups of patients often pose difficult diagnostic and therapeutic dilemmas owing to complex medical conditions and concurrent morbidities. In this chapter, we summarise the current evidence on the management of pelvic floor disorders, with emphasis on elderly women and the associations between the ageing process and these disorders. Clinicians with an understanding of the affect of ageing on the pelvic floor and lower urinary and gastrointestinal tract anatomy and function, and the complex interplay of other comorbidities, will be able to investigate, diagnose and treat appropriately there women. A holistic approach may result in substantial improvements in their quality of life. Copyright © 2013. Published by Elsevier Ltd.
The effect on lower spine muscle activation of walking on a narrow beam in virtual reality.
Antley, Angus; Slater, Mel
2011-02-01
To what extent do people behave in immersive virtual environments as they would in similar situations in a physical environment? There are many ways to address this question, ranging from questionnaires, behavioral studies, and the use of physiological measures. Here, we compare the onsets of muscle activity using surface electromyography (EMG) while participants were walking under three different conditions: on a normal floor surface, on a narrow ribbon along the floor, and on a narrow platform raised off the floor. The same situation was rendered in an immersive virtual environment (IVE) Cave-like system, and 12 participants did the three types of walking in a counter-balanced within-groups design. The mean number of EMG activity onsets per unit time followed the same pattern in the virtual environment as in the physical environment-significantly higher for walking on the platform compared to walking on the floor. Even though participants knew that they were in fact really walking at floor level in the virtual environment condition, the visual illusion of walking on a raised platform was sufficient to influence their behavior in a measurable way. This opens up the door for this technique to be used in gait and posture related scenarios including rehabilitation.
Low-floor bus design preferences of walking aid users during simulated boarding and alighting.
D'souza, Clive; Paquet, Victor; Lenker, James; Steinfeld, Edward; Bareria, Piyush
2012-01-01
Low-floor buses represent a significant improvement in accessible public transit for passengers with limited mobility. However, there is still a need for research on the inclusive design of transit buses to identify specific low-floor bus design conditions that are either particularly accommodating or challenging for passengers with functional and mobility impairments. These include doorway locations, seating configuration and the large front wheel-well covers that collectively impact boarding, alighting and interior movement of passengers. Findings from a laboratory study using a static full-scale simulation of a lowfloor bus to evaluate the impact of seating configuration and crowding on interior movement and accessibility for individuals with and without walking aids are presented (n=41). Simulated bus journeys that included boarding, fare payment, seating, and alighting were performed. Results from video observations and subjective assessments showed differences in boarding and alighting performance and users' perceptions of task difficulty. The need for assistive design features (e.g. handholds, stanchions), legroom and stowage space for walking aids was evident. These results demonstrate that specific design conditions in low-floor buses can significantly impact design preference among those who use walking aids. Consideration of ergonomics and inclusive design can therefore be used to improve the design of low-floor buses.
Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.
Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L
2016-09-01
Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance. Pelvic floor muscle collagen content was not altered by parity but increased dramatically with aging (P < .05). Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force-generating capacity of all pelvic floor muscles in the parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. Copyright © 2016 Elsevier Inc. All rights reserved.
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
Deusser, Rebecca E.; Schwab, William C.; Denny, Jane F.
2002-01-01
Researchers of the sea-floor mapping facility at the U.S. Geological Survey (USGS) Woods Hole Field Center in Woods Hole, Mass., use state-of-the-art technology to produce accurate geologic maps of the sea floor. In addition to basic bathymetry and morphology, sea-floor maps may contain information about the distribution of sand resources, patterns of coastal erosion, pathways of pollutant transport, and geologic controls on marine biological habitats. The maps may also show areas of human impacts, such as disturbance by bottom fishing and pollution caused by offshore waste disposal. The maps provide a framework for scientific research and provide critical information to decisionmakers who oversee resources in the coastal ocean.
Rejano-Campo, M; Desvergée, A; Pizzoferrato, A C
2018-03-01
Pelvic girdle pain (PGP) is characterized by the presence of pain in the posterior pelvic area, distally and laterally to the fifth lumbar vertebra, and/or at the pubic symphysis. PGP is a very common pain condition in women, especially during pregnancy and postpartum. After delivery, pain prevalence decreases to 7 % in the first three months. The current literature describes an association between pelvic girdle pain and different perineal characteristics and symptoms. A better understanding of perineal structures influence on PGP could assist towards the management of this condition. The aim of this review is to describe the peer-reviewed literature about perineal function in patients with PGP. A bibliographic search on PubMed was conducted. The key words used were: pelvic girdle pain, pregnacy-related low back pain, lumbopelvic pain, posterior pelvic pain, peripartum pelvic pain, pelvic girdle relaxation, pelvic joint instability, peripartum pelvic pain, sacroiliac joint pain, sacroiliac joint dysfunction, sacroiliac-joint related pelvic pain and pelvic floor. Two hundred and twenty-one (221) articles were identified. Out of them, a total of nine articles were selected. The level of evidence was determined using Oxford's scale. Patients with PGP showed increased activity of the pelvic floor muscles (P=0.05) (LE3), decreased urogenital hiatus area (PGP 12.4 cm 2 ±2.7, control 13.7 cm 2 ±2.8, P=0.015) (LE3), shorter endurance time (PGP 17.8 s; control 54.0 s, P=0.00) (LE3), significantly later onset time during affected side leg elevation (PGP 25ms, control -129ms, P=0.01) (LE3), levator ani and obturator internus tenderness (PGP 25/26; control 5/25, P<0.001) (LE3) and a higher prevalence of vesico-sphincteric disorders compared to asymptomatic subjects (LE3). This review confirms that subjects suffering PGP present particular perineal characteristics regarding morphology and biomechanics. It would be interesting to develop clinical research concerning pelvic floor release effect in PGP. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Global distribution of naturally occurring marine hypoxia on continental margins
NASA Astrophysics Data System (ADS)
Helly, John J.; Levin, Lisa A.
2004-09-01
Hypoxia in the ocean influences biogeochemical cycling of elements, the distribution of marine species and the economic well being of many coastal countries. Previous delineations of hypoxic environments focus on those in enclosed seas where hypoxia may be exacerbated by anthropogenically induced eutrophication. Permanently hypoxic water masses in the open ocean, referred to as oxygen minimum zones, impinge on a much larger seafloor surface area along continental margins of the eastern Pacific, Indian and western Atlantic Oceans. We provide the first global quantification of naturally hypoxic continental margin floor by determining upper and lower oxygen minimum zone depth boundaries from hydrographic data and computing the area between the isobaths using seafloor topography. This approach reveals that there are over one million km 2 of permanently hypoxic shelf and bathyal sea floor, where dissolved oxygen is <0.5 ml l -1; over half (59%) occurs in the northern Indian Ocean. We also document strong variation in the intensity, vertical position and thickness of the OMZ as a function of latitude in the eastern Pacific Ocean and as a function of longitude in the northern Indian Ocean. Seafloor OMZs are regions of low biodiversity and are inhospitable to most commercially valuable marine resources, but support a fascinating array of protozoan and metazoan adaptations to hypoxic conditions.
Characterization of the protective capacity of flooring systems using force-deflection profiling.
Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C
2013-01-01
'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Analysis of the performance and space conditioning impacts of dedicated heat pump water heaters
NASA Astrophysics Data System (ADS)
Morrison, L.; Swisher, J.
The development and testing of the newly-marketed dedicated heat pump water heater (HPWH) are described. This system utilizes an air-to-water heat pump, costs about $1,000 installed, and obtains a coefficient of performance (COP) of about 2.0 in laboratory and field tests. To investigate HPWH performance and space conditioning impacts, a simulation was developed to mode the thermal performance of a residence with resistance baseboard heat, air conditioning, and either heat pump or resistance water heating. The building characteristics are adapted for three U.S. geographical areas (Madison, Wisconsin; Washington, D.C.; and Ft. Worth, Texas), and the system is simulated for a year with typical weather data. The thermal network includes both a house node and a basement node so that the water heating equipment can be simulated in an unconditioned basement in Northern cities and in a conditioned first-floor utility room in Southern cities.
An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong
2011-03-15
Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.
Earthquake response of storey building in Jakarta using accelerographs data analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Julius, Admiral Musa, E-mail: admiralmusajulius@yahoo.com; Jakarta Geophysics Observatory, Indonesia Agency of Meteorology Climatology and Geophysics; Sunardi, Bambang, E-mail: b.sunardi@gmail.com
As seismotectonic, the Jakarta city will be greatly affected by the earthquake which originated from the subduction zone of the Sunda Strait and south of Java. Some occurrences of earthquakes in these location are often perceived by the occupants in the upper floors of multi-storey buildings in Jakarta but was not perceived by the occupants on the ground floor. The case shows the difference in ground-motion parameters on each floor height. The analysis of the earthquake data recorded by accelerographs on different floors need to be done to know the differences in ground-motion parameters. Data used in this research ismore » accelerograph data installed on several floors in the main building of Meteorology Climatology and Geophysics Agency with a case study of Kebumen earthquake on January 25{sup th} 2014. Parameters analyzed include the Peak Ground Acceleration (PGA), Peak Ground Displacement (PGD), Peak Spectral Acceleration (PSA), Amplification (Ag), and the Effective Duration of earthquake (t{sub e}). Research stages include accelerographs data acquisition in three (3) different floors, conversion and data partition for each component, conversion to units of acceleration, determination of PGA, PGD, PSA, Ag and t{sub e} as well as data analysis. The study shows the value of PGA on the ground floor, 7{sup th} floor and 15{sup th} floors, respectively are 0.016 g, 0.053 g and 0.116 g. PGD on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 2.15 cm, 2.98 cm and 4.92 cm. PSA on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 0.067 g, 0.308 g and 0.836 g. Amplification of the peak acceleration value on the ground floor, 7{sup th} floor and 15{sup th} floor to the surface rock are 4.37, 6.07 and 7.30. Effective duration of the earthquake on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 222.28 s, 202.28 s and 91.58 s. In general, with increasing floor of the building, the value of the peak ground acceleration, peak ground displacement, peak spectral acceleration and amplification growing, contrary to the value of the effective duration of earthquake decreases. The difference in this parameter is strongly influenced by local soil conditions and building construction.« less
Evaluation of conductive concrete for anti-static flooring applications
NASA Astrophysics Data System (ADS)
Yehia, Sherif; Qaddoumi, Nasser; Hassan, Mohamed; Swaked, Bassam
2015-04-01
Static electricity, exchange of electrons, and retention of charge between any two materials due to contact and separation are affected by the condition of the materials being nonconductive or insulated from ground. Several work environments, such as electronics industry, hospitals, offices, and computer rooms all require electro-static discharge (ESD) mitigation. Carpet Tile, Carpet Broadloom, Vinyl Tile, Vinyl sheet, Epoxy and Rubber are examples of existing flooring systems in the market. However, each system has its advantages and limitations. Conductive concrete is a relatively new material technology developed to achieve high electrical conductivity and high mechanical strength. The conductive concrete material can be an economical alternative for these ESD flooring systems. In this paper, the effectiveness of conductive concrete as an anti-static flooring system was evaluated. The initial results indicated that the proposed conductive concrete flooring and ground system met the acceptance criteria stated by ASTM F150.
Study Guide for Floorcovering [and Instructor's Key]. V&TECC Curriculum Guide.
ERIC Educational Resources Information Center
Duenk, Lester G.; And Others
Designed for use with industrial cooperative training programs, this study guide on floor covering installation presents the basic foundation knowledge which must be put to practice on the job. The guide begins with a floor covering occupational brief. Specific topics in this section include status of the occupation, working conditions, salary,…
Code of Federal Regulations, 2011 CFR
2011-10-01
... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be... vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the...
Preliminary study of TEC application in cooling system
NASA Astrophysics Data System (ADS)
Sulaiman, A. C.; Amin, N. A. M.; Saidon, M. S.; Majid, M. S. A.; Rahman, M. T. A.; Kazim, M. N. F. M.
2017-10-01
Integration of thermoelectric cooling (TEC) within a space cooling system in the lecturer room is studied. The studied area (air conditioned surrounding) is encapsulated with wall, floor, roof, and glass window. TEC module is placed on the glass window. The prototype of the studied compartment is designed using cabin container. The type and number of TEC module are studied and the effects on the cooling performance are analyzed as it is assumed to be tested within an air conditioned lecturer room. The experimental and mathematical modeling of the cooling system developed. It is expected that the mathematical modeling derived from this study will be used to estimate the use of the number of TEC module to be integrated with air conditioner unit where possible.
LPT. Shield test facility (TAN645 and 646). Floor plan and ...
LPT. Shield test facility (TAN-645 and -646). Floor plan and room names. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107347 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Guard House (TAN642). Elevations, floor plan, sections, details. Ralph ...
LPT. Guard House (TAN-642). Elevations, floor plan, sections, details. Ralph M. Parsons 1229-12 ANP/GE-7-642-A-S-H7V-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0642-00-693-107306 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Demineralization plant, TAN649. Floor plan, elevation details. Ralph M. ...
A&M. Demineralization plant, TAN-649. Floor plan, elevation details. Ralph M. Parsons 1480-4-ANP/GE-3-649-A-1. Date: October 1958. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0649-00-693-107439 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control and equipment building (TAN620) floor plan. Schedule of ...
IET. Control and equipment building (TAN-620) floor plan. Schedule of furniture and equipment. Ralph M. Parsons 902-4-ANP-A 320. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0620-00-693-106905 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Effects of different flooring options in outside pens of hutches on dairy calf growth
USDA-ARS?s Scientific Manuscript database
Growth rates of dairy calves may vary due to many different factors, including housing. The objective of this study was to determine if calf growth was affected by different flooring options in the outside penned area of a calf hutch. For this study, 33 hutches were blocked in groups of 3 by locatio...
Rules for Adaptive Learning and Assistance on the Shop Floor
ERIC Educational Resources Information Center
Ullrich, Carsten
2016-01-01
Today's shop floor, the area of a factory where operatives assemble products, is a complex and demanding work environment. The employed and produced technology becomes ever more complex, and employees are responsible for an increasing amount of tasks. As a consequence, the employee is under constant pressure to solve problems occurring on the shop…
138. ARAII Building ARA606 floor plan for remodel as Inel ...
138. ARA-II Building ARA-606 floor plan for remodel as Inel Welding Laboratory. Shows room divisions and welding stations to be installed. Aerojet Nuclear Company 1375-ARA-II-606-E-2. Date: June 1976. Ineel index code no. 070-0606-10-400-156552. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Control Building (PER619) floor plan and elevations. Room numbers ...
PBF Control Building (PER-619) floor plan and elevations. Room numbers and functions. Roof plans for "high" roof and rest of roof. Ebasco Services 1205-PER/PER 619-A-1. Date: July 1965. INEEL index no. 760-0619-00-205-123022 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETR, TRA642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN ...
ETR, TRA-642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN PLACE AND CONDUIT PRESERVED, HIGH-DENSITY CONCRETE IS PLACED BETWEEN THE THERMAL RING AND THE OUTER REACTOR FORM. INL NEGATIVE NO. 56-2400. Jack L. Anderson, Photographer, 6/10/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Beaulieu, Harry J; Beaulieu, Serrita; Brown, Chris
2008-06-01
Phenyl mercuric acetate (PMA) historically has been used as a catalyst in polyurethane systems. In the 1950s-1970s, PMA was used as a catalyst in the 3M Tartan brand polyurethane flexible floors that were installed commonly in school gymnasiums. Mercury vapor is released into air above the surface of these floors. Sampling mercury in bulk flooring material and mercury vapor in air was conducted in nine Idaho schools in the spring of 2006. These evaluations were conducted in response to concerns by school officials that the floors could contain mercury and could release the mercury vapor into the air, presenting a potential health hazard for students, staff, and visitors. Controlled abatement was conducted in one school where remodeling would impact the mercury-bearing flexible gym floors ( approximately 9,000 ft(2) total). The controlled abatement consisted of containment of the work area with negative air technology; worker protection, including mercury-specific training, use of personal protective equipment, and biological and exposure monitoring; and environmental protection, including proper disposal of mercury-bearing hazardous waste material.
Andreozzi, Jacqueline M; Brůža, Petr; Tendler, Irwin I; Mooney, Karen E; Jarvis, Lesley A; Cammin, Jochen; Li, Harold; Pogue, Brian W; Gladstone, David J
2018-06-01
The purpose of this study was to identify the optimal treatment geometry for total skin electron therapy (TSET) using a new optimization metric from Cherenkov image analysis, and to investigate the sensitivity of the Cherenkov imaging method to floor scatter effects in this unique treatment setup. Cherenkov imaging using an intensified charge coupled device (ICCD) was employed to measure the relative surface dose distribution as a 2D image in the total skin electron treatment plane. A 1.2 m × 2.2 m × 1 cm white polyethylene sheet was placed vertically at a source to surface distance (SSD) of 300 cm, and irradiated with 6 MeV high dose rate TSET beams. The linear accelerator coordinate system used stipulates 0° is the bottom of the gantry arc, and progresses counterclockwise so that gantry angle 270° produces a horizontal beam orthogonal to the treatment plane. First, all unique pairs of treatment beams were analyzed to determine the performance of the currently recommended symmetric treatment angles (±20° from the horizontal), compared to treatment geometries unconstrained to upholding gantry angle symmetry. This was performed on two medical linear accelerators (linacs). Second, the extent of the floor scatter contributions to measured surface dose at the extended SSD required for TSET were imaged using three gantry angles of incidence: 270° (horizontal), 253° (-17°), and 240° (-30°). Images of the surface dose profile at each angle were compared to the standard concrete floor when steel plates, polyvinyl chloride (PVC), and solid water were placed on the ground at the base of the treatment plane. Postprocessing of these images allowed for comparison of floor material-based scatter profiles with previously published simulation results. Analysis of the symmetric treatment geometry (270 ± 20°) and the identified optimal treatment geometry (270 + 23° and 270 - 17°) showed a 16% increase in the 90% isodose area for the latter field pair on the first linac. The optimal asymmetric pair for the second linac (270 + 25° and 270 - 17°) provided a 52% increase in the 90% isodose area when compared to the symmetric geometry. Difference images between Cherenkov images captured with test materials (steel, PVC, and solid water) and the control (concrete floor) demonstrated relative changes in the two-dimensional (2D) dose profile over a 1 × 1.9 m region of interest (ROI) that were consistent with published simulation data. Qualitative observation of the residual images demonstrates localized increases and decreases with respect to the change in floor material and gantry angle. The most significant changes occurred when the beam was most directly impinging the floor (gantry angle 240°, horizontal -30°), where the PVC floor material decreased scatter dose by 1-3% in 7.2% of the total ROI area, and the steel plate increased scatter dose by 1-3% in 7.0% of the total ROI area. An updated Cherenkov imaging method identified asymmetric, machine-dependent TSET field angle pairs that provided much larger 90% isodose areas than the commonly adopted symmetric geometry suggested by Task Group 30 Report 23. A novel demonstration of scatter dose Cherenkov imaging in the TSET field was established. © 2018 American Association of Physicists in Medicine.
Methane from shallow seep areas of the NW Svalbard Arctic margin does not reach the sea surface
NASA Astrophysics Data System (ADS)
Silyakova, Anna; Greinert, Jens; Jansson, Pär; Ferré, Bénédicte
2015-04-01
Methane, an important greenhouse gas, leaks from large areas of the Arctic Ocean floor. One overall question is how much methane passes from the seabed through the water column, potentially reaching the atmosphere. Transport of methane from the ocean floor into and through the water column depends on many factors such as distribution of gas seeps, microbial methane oxidation, and ambient oceanographic conditions, which may trigger a change in seep activity. From June-July 2014 we investigated dissolved methane in the water column emanating from the "Prins Karls Forland seeps" area offshore the NW Svalbard Arctic margin. Measurements of the spatial variability of dissolved methane in the water column included 65 CTD stations located in a grid covering an area of 30 by 15 km. We repeated an oceanographic transect twice in a week for time lapse studies, thus documenting significant temporal variability in dissolved methane above one shallow seep site (~100 m water depth). Analysis of both nutrient concentrations and dissolved methane in water samples from the same transect, reveal striking similarities in spatial patterns of both dissolved methane and nutrients indicating that microbial community is involved in methane cycling above the gas seepage. Our preliminary results suggest that although methane release can increase in a week's time, providing twice as much dissolved gas to the water column, no methane from a seep reaches the sea surface. Instead it spreads horizontally under the pycnocline. Yet microbial communities react rapidly to the methane supply above gas seepage areas and may also have an important role as an effective filter, hindering methane release from the ocean to the atmosphere during rapid methane ebullition. This study is funded by CAGE (Centre for Arctic Gas Hydrate, Environment and Climate), Norwegian Research Council grant no. 223259.
Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å
2016-06-01
To study the correlation between palpation, perineometry and transperineal ultrasound for assessment of pelvic floor muscle contraction and to define a contraction scale for ultrasound measurements. This was a cross-sectional study of 608 women examined with palpation of pelvic floor muscle contraction, using the Modified Oxford Scale, and measurement of the vaginal squeeze pressure with a vaginal balloon connected to a fiber-optic microtip transducer (perineometry). Transperineal ultrasound was used for measurements of levator hiatal area and anteroposterior (AP) diameter in the plane of minimal hiatal dimensions, at rest and on contraction. The pelvic floor muscle contraction was expressed as the percentage difference between values at rest and on contraction. Spearman's rank was used to test for correlation between the different methods of assessment. Significant correlations were found between all assessment methods (P < 0.001). Palpation correlated with perineometry (rs = 0.74) and with proportional change in hiatal area (rs = 0.67) and AP diameter (rs = 0.69) on ultrasound. Perineometry correlated with proportional change in hiatal area (rs = 0.60) and AP diameter (rs = 0.66) on ultrasound. We defined a contraction scale based on the proportional change in AP diameter. In this population, a change in AP diameter of < 7% corresponded to absence of contractions, 7-18% corresponded to weak contractions, 18-35% corresponded to normal contractions and > 35% corresponded to strong contractions. We found moderate to strong correlation between ultrasound measurements, palpation and perineometry for assessing pelvic floor muscle contraction. The proportional change in levator hiatal AP diameter was the ultrasound measurement with strongest correlation to palpation and perineometry and formed the basis for the contraction scale for ultrasound measurements. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Field evaluation of two commonly used slipmeters.
Chang, Wen-Ruey; Cotnam, John P; Matz, Simon
2003-01-01
A variety of slipmeters have been used to assess the slipperiness of floor surfaces. International standards for the operation of slipmeters describe the protocol for a single measurement. These standards usually do not cover some of the critical elements in safety assessment such as methods for the selection of measurement locations and the necessary number of repeated measurements at each location. Furthermore, most of the slipmeters were evaluated in laboratory settings with new floor surfaces and artificial contaminants. Two commonly used slipmeters, the Brungraber Mark II and the English XL, were evaluated at actual worksites in this experiment. Four floor tiles in each of four different work areas in the kitchens of 18 fast food restaurants were selected for repeated measurements with these two slipmeters. The results indicated that sanding of footwear materials has a significant effect on the outcomes of friction measurements, and the tile-to-tile variations in friction in the same areas of restaurants were also mostly statistically significant. Significant local variation in friction among tiles in the same area could potentially increase the chances of slip and fall incidents. Both slipmeters used in this experiment could potentially have problems in the areas with grease, such as grill and fryer areas, since the build-up of grease during repeated strikes could alter the outcome of friction measured.
Carbon dioxide and methane emissions from the scale model of open dairy lots.
Ding, Luyu; Cao, Wei; Shi, Zhengxiang; Li, Baoming; Wang, Chaoyuan; Zhang, Guoqiang; Kristensen, Simon
2016-07-01
To investigate the impacts of major factors on carbon loss via gaseous emissions, carbon dioxide (CO2) and methane (CH4) emissions from the ground of open dairy lots were tested by a scale model experiment at various air temperatures (15, 25, and 35 °C), surface velocities (0.4, 0.7, 1.0, and 1.2 m sec(-1)), and floor types (unpaved soil floor and brick-paved floor) in controlled laboratory conditions using the wind tunnel method. Generally, CO2 and CH4 emissions were significantly enhanced with the increase of air temperature and velocity (P < 0.05). Floor type had different effects on the CO2 and CH4 emissions, which were also affected by air temperature and soil characteristics of the floor. Although different patterns were observed on CH4 emission from the soil and brick floors at different air temperature-velocity combinations, statistical analysis showed no significant difference in CH4 emissions from different floors (P > 0.05). For CO2, similar emissions were found from the soil and brick floors at 15 and 25 °C, whereas higher rates were detected from the brick floor at 35 °C (P < 0.05). Results showed that CH4 emission from the scale model was exponentially related to CO2 flux, which might be helpful in CH4 emission estimation from manure management. Gaseous emissions from the open lots are largely dependent on outdoor climate, floor systems, and management practices, which are quite different from those indoors. This study assessed the effects of floor types and air velocities on CO2 and CH4 emissions from the open dairy lots at various temperatures by a wind tunnel. It provided some valuable information for decision-making and further studies on gaseous emissions from open lots.
NASA Astrophysics Data System (ADS)
Aghababaei, Sajjad; Saeedi, Gholamreza; Jalalifar, Hossein
2016-05-01
The floor failure at longwall face decreases productivity and safety, increases operation costs, and causes other serious problems. In Parvadeh-I coal mine, the timber is used to prevent the puncture of powered support base into the floor. In this paper, a rock engineering system (RES)-based model is presented to evaluate the risk of floor failure mechanisms at the longwall face of E 2 and W 1 panels. The presented model is used to determine the most probable floor failure mechanism, effective factors, damaged regions and remedial actions. From the analyzed results, it is found that soft floor failure is dominant in the floor failure mechanism at Parvadeh-I coal mine. The average of vulnerability index (VI) for soft, buckling and compressive floor failure mechanisms was estimated equal to 52, 43 and 30 for both panels, respectively. By determining the critical VI for soft floor failure mechanism equal to 54, the percentage of regions with VIs beyond the critical VI in E 2 and W 1 panels is equal to 65.5 and 30, respectively. The percentage of damaged regions showed that the excess amount of used timber to prevent the puncture of weak floor below the powered support base is equal to 4,180,739 kg. RES outputs and analyzed results showed that setting and yielding load of powered supports, length of face, existent water at face, geometry of powered supports, changing the cutting pattern at longwall face and limiting the panels to damaged regions with supercritical VIs could be considered to control the soft floor failure in this mine. The results of this research could be used as a useful tool to identify the damaged regions prior to mining operation at longwall panel for the same conditions.
NASA Astrophysics Data System (ADS)
Ohkura, Hiroshi
Full polarimetric SAR images of ALOS PALSAR of Shinmoe-dake volcano in Japan were analyzed. The volcano erupted in January, 2011 and volcano ash deposited more than 10 cm in 12 km (2) and 1 m in 2 km (2) . Two images before and after the eruption were compared based on a point view of the four-component scattering model to detect changes of polarimetric scattering characteristics. The main detected changes are as follows. Total power of the four-component scattering model decreased on a farslope after the eruption. An incident angle on a farslope is larger than the angle on a foreslope. Decrease of surface roughness due to deposited volcanic ashes makes back-scattering smaller in the area of a larger incidence angle. However the rate of the double-bounce component got higher in a forest at the foot of a mountain slope and on a plain, where the ground surface is almost horizontal and the incident angle is relatively-large. Decrease of roughness of the forest floor increases forward scattering on the floor of the larger incident angle. This increases the double-bounced scattering due to bouncing back between the forest floor and trunks which stand "perpendicularly" on the almost horizontal forest floor. The rate of the surface scattering component got higher around an area where layover occurred. In the study area, most of layovers occurred at a ridge where an incidence angle was small. Decrease of surface roughness due to the ash deposit increases the surface scattering power in the area of the small incidence angle.
2014-04-03
CAPE CANAVERAL, Fla. – The Mobile Launcher is visible through a window inside Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
DESIGN AND HAZARDS SUMMARY REPORT, BOILING REACTOR EXPERIMENT V (BORAX V)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1961-05-01
Design data for BORAX V are presented along with results of hazards evaluation studies. Considcration of the hazards associated with the operation of BORAX V was based on the following conditions: For normal steady-state power and experimental operation, the reactor and plant are adequately shielded and ventilated to allow personnel to be safely stationed in the turbine building and on the main floor of the reactor building. The control building is located one- half mile distant from the reactor building. For special, hazardous experiments, personnel are withdrawn from the reactor area. (M.C.G.)
Said, Hakim K; Bevers, Michael; Butler, Charles E
2007-12-01
Patients who undergo pelvic floor resection as treatment for recurrent cancer following radiation therapy have increased rates of complications, particularly if permanent prosthetic mesh is used for reconstruction. Human acellular dermal matrix (HADM), commonly used for reconstruction in other torso locations, is associated with lower rates of complications (including infection, adhesions and cutaneous exposure) than synthetic mesh. We describe an effective technique to reconstruct the pelvic floor and perineum with HADM and thigh-based flaps following pelvic exenteration and radical vulvectomy. A 75-year-old woman underwent radical resection of the pelvic floor and perineum to treat recurrent vulvar squamous cell carcinoma and osteoradionecrosis. The pelvic floor and perineal soft tissue defect were reconstructed with HADM (AlloDerm; LifeCell Corporation, Branchburg, NJ) and bilateral, thigh-based tissue flaps, respectively. Despite a large resection, previous irradiation therapy and bacterial contamination the wounds healed without complications. Reconstruction of pelvic floor defects using HADM is an option when wound conditions are unfavorable for the use of permanent prosthetic meshes.
Dairy cow preferences for soft or hard flooring when standing or walking.
Telezhenko, E; Lidfors, L; Bergsten, C
2007-08-01
Concrete is the most commonly used alley flooring in confined dairy herds because of its qualities of construction and ease of cleaning. Nevertheless, the hardness, abrasiveness, and slipperiness of concrete floors have adverse effects on animal well-being and health, and yielding rubber flooring is becoming popular as a way of improving the flooring conditions on walkways. The aim of this study was to investigate preferences of dairy cows for rubber compared with concrete flooring under the conditions of a commercial dairy farm. The study was conducted in an organic dairy herd with free-stall housing. Floor preference was tested on groups of standing cows in a 120-m2 holding pen before milking, and 1 yr later on a 12- x 3-m walkway. The holding pen and the walkway were divided lengthwise into 2 identical sections. Two types of solid rubber mats (soft and extra soft) were tested against solid concrete in the holding pen. Slatted and solid rubber mats were tested against slatted concrete in the walkway. Each floor type was tested over 4 d on the left side and 4 d on the right side of the holding pen and the walkway, respectively. Concrete flooring on both sides of the sections was tested as a control before the testing of different section materials. All observations of the distribution of cows in the sections were made from video recordings captured in association with the afternoon milking. The number of cows on each section was recorded approximately every 7 min in the holding pen, and continuously on the walkway. A significantly higher proportion of cows stood on the side with the soft and extra soft rubber mats (65.1 +/- 2.7 and 69.3 +/- 2.6%, respectively, mean +/- SEM) compared with the control distribution when only the solid concrete was available (50.9 +/- 3.9%). A significantly higher proportion of nonlame cows walked exclusively on the side with the slatted (64.5 +/- 5.4%, d 4) or solid rubber mats (68.2 +/- 5.1%, d 4) compared with controls (28.9 +/- 4.3%). Lame cows within a group of walking cows did not show a higher preference for soft flooring as distinct as nonlame cows (52.7 +/- 6.9 and 59.4 +/- 6.2% for the solid and slatted rubber mats, respectively, at d 4 vs. 40.3 +/- 6.2% for control), presumably because of competition with other, higher ranked cows. It was concluded that the majority of cows preferred to walk and stand on soft rubber rather than on concrete flooring.
Measuring Room Area or Volume Electronically
NASA Technical Reports Server (NTRS)
Kavaya, M. J.
1987-01-01
Area- and volume-measuring instrument hand-held or mounted on tripod. Instrument rapidly measures distances to walls, ceiling, or floor at many viewing angles and automatically computes area or volume of room. Results obtained rapidly with minimal effort.
The Combine Use of Semi-destructive and Non-destructive Methods for Tiled Floor Diagnostics
NASA Astrophysics Data System (ADS)
Štainbruch, Jakub; Bayer, Karol; Jiroušek, Tomáš; Červinka, Josef
2017-04-01
The combination of semi-destructive and non-destructive methods was used to asset the conditions of a tiled floor in the historical monument Minaret, situated in the park complex of the Chateau Lednice (South Moravia Region, Czech Republic), before its renovation. Another set of measurements is going to be performed after the conservation works are finished. (The comparison of the results collected during pre- and post-remediation measurements will be known and presented during the General Assembly meeting in Wien.) The diagnostic complex of methods consisted of photogrammetry, resistivity drilling and georadar. The survey was aimed to contour extends of air gaps beneath the tiles and the efficiency of filling gaps by means of injection, consolidation and gluing individual layers. The state chateau Lednice creates a part of the Lednice-Valtice precinct, a UNESCO landmark, and belongs among the greatest historic monuments in Southern Moravia. In the chateau park there is a romantic observation tower in the shape of a minaret built according to the plans of Josef Hardtmuth between 1798-1804. The Minaret has been extensively renovated for many decades including the restoration of mosaic floors from Venetian terazzo. During the static works of the Minaret building between 1999-2000, the mosaic floors in the rooms on the second floor were transferred and put back onto concrete slabs. Specifically, the floor was cut up to tiles and these were glued to square slabs which were then attached to the base plate. The transfer was not successful and the floor restoration was finalized between 2016-2017. The damage consisted in separating the original floor from the concrete plate which led to creating gaps. Furthermore, the layers of the floor were not compact. It was necessary to fill the gaps and consolidate and glue the layers. The existence of air gap between individual layers of the tiles and their degradation was detected using two different diagnostic methods: semi-destructive resistivity drilling, and non-destructive georadar, and the results were compared. Floors were measured by 3D laser scanning technology and captured by the camera before reconstruction work. Using SFM photogrammetry were achieved results: ortomozaik (0.3 mm / pix) and DEM (0.6 mm / pix). These results were a basis for restoration work and also allow comparisons with the original state at any stage of the project. Drilling resistance measurement is used for indirect determination of strength profile based on resistance to drilling depending on into the depth. The observed resistance to drilling correlates with the strength and toughness of the measured material. The method is referred as a micro- or semi-invasive, since sampling is not necessary and but the drilling diameter is usually 3-5 mm. The ultrasonic measurement consists in the measuring of the longitude as well as the transverse waves - velocity, shape, amplitude. The propagation velocity is a characteristic values for the material influenced by its composition and compactness. Georadar (GPR) is a high frequency electromagnetic pulse method. For measurement the GPR RAMAC system coupled with 1600 MHz shielded antenna was used. Two tiles (one with defects and one in relatively good condition) were surveyed in a regular grid of perpendicular lines 5 cm separated. Data were processed by means of ReflexW software and performed in the form of cross sections and amplitude maps. The map of the amplitude summed over a time window 1 - 1,4 ns (representing the intensity of the reflection from the tiles bottom) gave good result. The areas of registered relatively high amplitudes correspond with the position of airgaps. A correlation was observed between the results of different survey methods.
Gait of dairy cows on floors with different slipperiness.
Telezhenko, E; Magnusson, M; Bergsten, C
2017-08-01
This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the coefficient of friction, but the effect of pattern was better detected by skid-resistance measurements. Consequently, several physical characteristics are needed to objectively describe the slip resistance of cattle floors. Soft rubber mats gave better tracking than hard, solid floors, even with a grooved surface or a tamped pattern. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
ETRCF, TRA654, INTERIOR. CAMERA IS ON MAIN FLOOR. NOTE CRANE ...
ETR-CF, TRA-654, INTERIOR. CAMERA IS ON MAIN FLOOR. NOTE CRANE HOOKS. ELECTRICAL EQUIPMENT IS PART OF PAST EXPERIMENT. DOOR AT LEFT EDGE OF VIEW LEADS TO REACTOR SERVICE BUILDING, TRA-635. INL NEGATIVE NO. HD24-1-2. Mike Crane, Photographer, ca. 2003 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. REACTOR IS IN CENTER ...
ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. REACTOR IS IN CENTER OF VIEW. CAMERA FACES NORTHWEST. NOTE CRANE RAILS AND DANGLING ELECTRICAL CABLE AT UPPER PART OF VIEW FOR "MOFFETT 2 TON" CRANE. INL NEGATIVE NO. HD46-14-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
FET. Control and equipment building (TAN630). Basement floor plan. Tunnel ...
FET. Control and equipment building (TAN-630). Basement floor plan. Tunnel to hangar (TAN-629). Electrical and chemical services. Ralph M. Parsons 1229-2 ANP/GE-630-A-1. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107080 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR, TRA642. ON BASEMENT FLOOR. REACTOR VESSEL WILL BE PLACED ...
ETR, TRA-642. ON BASEMENT FLOOR. REACTOR VESSEL WILL BE PLACED WITHIN THE INNER METAL FORM. WHEN CONCRETE IS POURED OUTSIDE THIS FORM, CONDUIT HOLES WILL BE PRESERVE SPACE THROUGH HOLES. INL NEGATIVE NO. 56-1507. Jack L. Anderson, Photographer, 5/8/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
36. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR ...
36. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR CORRIDOR ON THE EAST SIDE OF THE DISASSEMBLY BAY. A VIEWING AND WORK STATION AND ENTRANCE TO THE CONTROL ROOM ARE ON THE WEST SIDE OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
26. DETAIL OF STRUCTURAL COLLAPSE OF TOP FLOOR OF MILL, ...
26. DETAIL OF STRUCTURAL COLLAPSE OF TOP FLOOR OF MILL, ABOVE ORE BIN, LOOKING WEST FROM TOP OF STAIRWAY IN CA-290-25. THE PIPE AT CENTER WAS USED TO SPREAD CRUSHED ORE COMING FROM THE JAW CRUSHER EVENLY TO ALL AREA OF THE ORE BIN BELOW. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA
MTR WING, TRA604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, ...
MTR WING, TRA-604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, INSTRUMENT SHOP, COUNTING ROOM, HEALTH PHYSICS LAB, LABS AND OFFICES, STORAGE, SHIPPING AND RECEIVING. BLAW-KNOX 3150-4-2, 7/1950. INL INDEX NO. 053-604-00-099-100008, REV. 7. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ADM. Fuel Pump House (TAN611). Elevations, floor plan. Drawing includes ...
ADM. Fuel Pump House (TAN-611). Elevations, floor plan. Drawing includes elevation and plans for "H.M." structures (Hose Storage?). Ralph M. Parsons 902-2-ANP-611-A 78 Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0611-00-693-106741 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
is limited. Check the calendar for dates and registration. Visitors meet in the Wilson Hall atrium and making your way to the 1st floor of Wilson Hall in time for the tour. Fermilab is a busy lab so Fermilab's exhibit and viewing areas on the 15th floor of Wilson Hall are open Monday-Friday from 8 a.m. to 4
FET. Control and equipment building, TAN630. Main floor plan. Control ...
FET. Control and equipment building, TAN-630. Main floor plan. Control room. Room numbers and functions. Ralph M. Parsons. 1229-2-ANP/GE-5-630-A-2. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107081 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. TAN607. Foundation plan for hot shop floor and pool. ...
A&M. TAN-607. Foundation plan for hot shop floor and pool. Tunnels to turntable. Motor pit. Ralph M. Parsons 902-3-ANP-607-S128. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-62-693-160722 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Jonatha L. Horton; Barton D. Clinton; John F. Walker; Colin M. Beir; Erik T. Nilsen
2009-01-01
Ericaceous shrubs can influence soil properties in many ecosystems. In this study, we examined how soil and forest floor properties vary among sites with different ericaceous evergreen shrub basal area in the southern Appalachian mountains. We randomly located plots along transects that included open understories and understories with varying amounts of Rhododendron...
General view of the shop floor looking north in the ...
General view of the shop floor looking north in the Vertical Processing Area of the Space Shuttle Main Engine (SSME) Processing Facility at Kennedy Space Center. SSME number 2061's nozzle is being inspected by an SSME technician in the foreground. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
4. "ARCHITECTURAL, FLOOR PLAN-ELEVATIONS-SECTIONS, OBSERVATION BUNKERS." Specifications No. ENG (NASA)04-353-63-1; Drawing No. 60-09-34; sheet 325. Ref. No. A-13. D.O. SERIES 1597/87. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunker 1-D-3, Test Area 1-125, northwest end of Altair Boulevard, Boron, Kern County, CA
FAST CHOPPER DETECTOR HOUSE, TRA665. SECOND FLOOR ADDITION: PLAN, SECTIONS ...
FAST CHOPPER DETECTOR HOUSE, TRA-665. SECOND FLOOR ADDITION: PLAN, SECTIONS AND DETAILS AS ADDED TO THE EXISTING CHOPPER HOUSE IN 1962. F.C. TORKELSON 842-MTR-665-S-3, 4/1962. INL INDEX NO. 531-0665-60-851-150997, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
20. VIEW TO WEST OF INTERIOR OF CRANEWAY WITH TOW ...
20. VIEW TO WEST OF INTERIOR OF CRANEWAY WITH TOW TRAVELING BRIDGE CRANES (ONE OVERHEAD IN FOREGROUND AND ONE OVERHEAD IN BACKGROUNDS). NOTE WOOD BLOCK PAVING ON THE FLOOR. FIRST FLOOR ASSEMBLY AREA IS THE SPACE IN THE BACKGROUND ON THE RIGHT. - Rosie the Riveter National Historical Park, Ford Assembly Plant, 1400 Harbour Way South, Richmond, Contra Costa County, CA
Contreras Ortiz, Oscar; Rizk, Diaa Ee; Falconi, Gabriele; Schreiner, Lucas; Gorbea Chávez, Viridiana
2017-02-01
For four decades, the training for fellows in Urogynecology has been defined by taking into account the proposals of the relevant international societies. Primary health care providers and general OB/GYN practitioners could not find validated guidelines for the integration of knowledge in pelvic floor dysfunctions. The FIGO Working Group (FWG) in Pelvic Floor Medicine and Reconstructive Surgery has looked for the consensus of international opinion leaders in order to develop a set of minimal requirements of knowledge and skills in this area. This manuscript is divided into three categories of knowledge and skills, these are: to know, to understand, and to perform in order to offer the patients a more holistic health care in this area. The FWG reached consensus on the minimal requirements of knowledge and skills regarding each of the enabling objectives identified for postgraduate obstetrics and gynecology physicians and for residents in obstetrics and gynecology. Our goal is to propose and validate the basic objectives of minimal knowledge in pelvic floor medicine and reconstructive surgery. Neurourol. Urodynam. 36:514-517, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Stone Age hut in Israel yields world's oldest evidence of bedding
Nadel, Dani; Weiss, Ehud; Simchoni, Orit; Tsatskin, Alexander; Danin, Avinoam; Kislev, Mordechai
2004-01-01
The earliest archaeological remains of dwelling huts built by Homo sapiens were found in various European Upper Paleolithic open-air camps. Although floors of huts were found in a small number of cases, modern organization of the home space that includes defined resting areas and bedding remains was not discovered. We report here the earliest in situ bedding exposed on a brush hut floor. It has recently been found at the previously submerged, excellently preserved 23,000-year-old fisher-hunter-gatherers' camp of Ohalo II, situated in Israel on the shore of the Sea of Galilee. The grass bedding consists of bunches of partially charred Puccinellia confer convoluta stems and leaves, covered by a thin compact layer of clay. It is arranged in a repeated pattern, on the floor, around a central hearth. This study describes the bedding in its original context on a well preserved intentionally constructed floor. It also reconstructs on the basis of direct evidence (combined with ethnographic analogies) the Upper Paleolithic hut as a house with three major components: a hearth, specific working locales, and a comfortable sleeping area near the walls. PMID:15090648
Tomelleri, Christopher; Waldner, Andreas; Werner, Cordula; Hesse, Stefan
2011-01-01
The main goal of robotic gait rehabilitation is the restoration of independent gait. To achieve this goal different and specific patterns have to be practiced intensively in order to stimulate the learning process of the central nervous system. The gait robot G-EO Systems was designed to allow the repetitive practice of floor walking, stair climbing and stair descending. A novel control strategy allows training in adaptive mode. The force interactions between the foot and the ground were analyzed on 8 healthy volunteers in three different conditions: real floor walking on a treadmill, floor walking on the gait robot in passive mode, floor walking on the gait robot in adaptive mode. The ground reaction forces were measured by a Computer Dyno Graphy (CDG) analysis system. The results show different intensities of the ground reaction force across all of the three conditions. The intensities of force interactions during the adaptive training mode are comparable to the real walking on the treadmill. Slight deviations still occur in regard to the timing pattern of the forces. The adaptive control strategy comes closer to the physiological swing phase than the passive mode and seems to be a promising option for the treatment of gait disorders. Clinical trials will validate the efficacy of this new option in locomotor therapy on the patients. © 2011 IEEE
Stafford, Ryan E; Aljuraifani, Rafeef; Hug, François; Hodges, Paul W
2017-04-01
To investigate whether increases in stiffness can be detected in the anatomical region associated with the striated urethral sphincter (SUS) during voluntary activation using shear-wave elastography (SWE); to identify the location and area of the stiffness increase relative to the point of greatest dorsal displacement of the mid urethra (i.e. SUS); and to determine the relationship between muscle stiffness and contraction intensity. In all, 10 healthy men participated. A linear ultrasound (US) transducer was placed mid-sagittal on the perineum adjacent to a pair of electromyography electrodes that recorded non-specific pelvic floor muscle activity. Stiffness in the area expected to contain the SUS was estimated via US SWE at rest and during voluntary pelvic floor muscles contractions to 5%, 10% and 15% maximum. Still image frames were exported for each repetition and analysed with software that detected increases in stiffness above 150% of the resting stiffness. Pelvic floor muscle contraction elicited an increase in stiffness above threshold within the region expected to contain the SUS for all participants and contraction intensities. The mean (SD) ventral-dorsal distance between the centre of the stiffness area and region of maximal motion of the mid-urethra (caused by SUS contraction) was 5.6 (1.8), 6.2 (0.8), and 5.8 (0.7) mm for 5%, 10% and 15% maximal voluntary contraction, respectively. Greater pelvic floor muscle contraction intensity resulted in a concomitant increase in stiffness, which differed between contraction intensities (5% vs 10%, P < 0.001; 5% vs 15%, P < 0.001; 10% vs 15%, P = 0.003). Voluntary contraction of the pelvic floor muscles in men is associated with an area of stiffness increase measured with SWE, which concurs with the expected location of the SUS. The increase in stiffness occurred in association with an increase in perineal surface electromyography activity, providing evidence that stiffness amplitude relates to general pelvic floor muscle contraction intensity. Future applications of SWE may include investigations of patient populations in which dysfunction of the SUS is thought to play an important role, or investigation of the effect of rehabilitation programmes that target this muscle. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Brain Mechanisms Underlying Urge Incontinence and its Response to Pelvic Floor Muscle Training.
Griffiths, Derek; Clarkson, Becky; Tadic, Stasa D; Resnick, Neil M
2015-09-01
Urge urinary incontinence is a major problem, especially in the elderly, and to our knowledge the underlying mechanisms of disease and therapy are unknown. We used biofeedback assisted pelvic floor muscle training and functional brain imaging (functional magnetic resonance imaging) to investigate cerebral mechanisms, aiming to improve the understanding of brain-bladder control and therapy. Before receiving biofeedback assisted pelvic floor muscle training functionally intact, older community dwelling women with urge urinary incontinence as well as normal controls underwent comprehensive clinical and bladder diary evaluation, urodynamic testing and brain functional magnetic resonance imaging. Evaluation was repeated after pelvic floor muscle training in those with urge urinary incontinence. Functional magnetic resonance imaging was done to determine the brain reaction to rapid bladder filling with urgency. Of 65 subjects with urge urinary incontinence 28 responded to biofeedback assisted pelvic floor muscle training with 50% or greater improvement of urge urinary incontinence frequency on diary. However, responders and nonresponders displayed 2 patterns of brain reaction. In pattern 1 in responders before pelvic floor muscle training the dorsal anterior cingulate cortex and the adjacent supplementary motor area were activated as well as the insula. After the training dorsal anterior cingulate cortex/supplementary motor area activation diminished and there was a trend toward medial prefrontal cortex deactivation. In pattern 2 in nonresponders before pelvic floor muscle training the medial prefrontal cortex was deactivated, which changed little after the training. In older women with urge urinary incontinence there appears to be 2 patterns of brain reaction to bladder filling and they seem to predict the response and nonresponse to biofeedback assisted pelvic floor muscle training. Moreover, decreased cingulate activation appears to be a consequence of the improvement in urge urinary incontinence induced by training while prefrontal deactivation may be a mechanism contributing to the success of training. In nonresponders the latter mechanism is unavailable, which may explain why another form of therapy is required. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Paton, Susan; Thompson, Katy-Anne; Parks, Simon R; Bennett, Allan M
2015-08-01
The aim of this study was to quantify reaerosolization of microorganisms caused by walking on contaminated flooring to assess the risk to individuals accessing areas contaminated with pathogenic organisms, for example, spores of Bacillus anthracis. Industrial carpet and polyvinyl chloride (PVC) floor coverings were contaminated with aerosolized spores of Bacillus atrophaeus by using an artist airbrush to produce deposition of ∼10(3) to 10(4) CFU · cm(-2). Microbiological air samplers were used to quantify the particle size distribution of the aerosol generated when a person walked over the floorings in an environmental chamber. Results were expressed as reaerosolization factors (percent per square centimeter per liter), to represent the ratio of air concentration to surface concentration generated. Walking on carpet generated a statistically significantly higher reaerosolization factor value than did walking on PVC (t = 20.42; P < 0.001). Heavier walking produced a statistically significantly higher reaerosolization factor value than did lighter walking (t = 12.421; P < 0.001). Height also had a statistically significant effect on the reaerosolization factor, with higher rates of recovery of B. atrophaeus at lower levels, demonstrating a height-dependent gradient of particle reaerosolization. Particles in the respirable size range were recovered in all sampling scenarios (mass mean diameters ranged from 2.6 to 4.1 μm). The results of this study can be used to produce a risk assessment of the potential aerosol exposure of a person accessing areas with contaminated flooring in order to inform the choice of appropriate respiratory protective equipment and may aid in the selection of the most suitable flooring types for use in health care environments, to reduce aerosol transmission in the event of contamination. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Thompson, Katy-Anne; Parks, Simon R.; Bennett, Allan M.
2015-01-01
The aim of this study was to quantify reaerosolization of microorganisms caused by walking on contaminated flooring to assess the risk to individuals accessing areas contaminated with pathogenic organisms, for example, spores of Bacillus anthracis. Industrial carpet and polyvinyl chloride (PVC) floor coverings were contaminated with aerosolized spores of Bacillus atrophaeus by using an artist airbrush to produce deposition of ∼103 to 104 CFU · cm−2. Microbiological air samplers were used to quantify the particle size distribution of the aerosol generated when a person walked over the floorings in an environmental chamber. Results were expressed as reaerosolization factors (percent per square centimeter per liter), to represent the ratio of air concentration to surface concentration generated. Walking on carpet generated a statistically significantly higher reaerosolization factor value than did walking on PVC (t = 20.42; P < 0.001). Heavier walking produced a statistically significantly higher reaerosolization factor value than did lighter walking (t = 12.421; P < 0.001). Height also had a statistically significant effect on the reaerosolization factor, with higher rates of recovery of B. atrophaeus at lower levels, demonstrating a height-dependent gradient of particle reaerosolization. Particles in the respirable size range were recovered in all sampling scenarios (mass mean diameters ranged from 2.6 to 4.1 μm). The results of this study can be used to produce a risk assessment of the potential aerosol exposure of a person accessing areas with contaminated flooring in order to inform the choice of appropriate respiratory protective equipment and may aid in the selection of the most suitable flooring types for use in health care environments, to reduce aerosol transmission in the event of contamination. PMID:25979883
Finite Element Models and Properties of a Stiffened Floor-Equipped Composite Cylinder
NASA Technical Reports Server (NTRS)
Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.
2010-01-01
Finite element models were developed of a floor-equipped, frame and stringer stiffened composite cylinder including a coarse finite element model of the structural components, a coarse finite element model of the acoustic cavities above and below the beam-supported plywood floor, and two dense models consisting of only the structural components. The report summarizes the geometry, the element properties, the material and mechanical properties, the beam cross-section characteristics, the beam element representations and the boundary conditions of the composite cylinder models. The expressions used to calculate the group speeds for the cylinder components are presented.
Expendable oceanographic sensor apparatus
McCoy, Kim O.; Downing, Jr., John P.; DeRoos, Bradley G.; Riches, Michael R.
1993-01-01
An expendable oceanographic sensor apparatus is deployed from an airplane or a ship to make oceanographic observations in a profile of the surface-to-ocean floor, while deployed on the floor, and then a second profile when returning to the ocean surface. The device then records surface conditions until on-board batteries fail. All data collected is stored and then transmitted from the surface to either a satellite or other receiving station. The apparatus is provided with an anchor that causes descent to the ocean floor and then permits ascent when the anchor is released. Anchor release is predetermined by the occurrence of a pre-programmed event.
Low-to-moderate Reynolds number swirling flow in an annular channel with a rotating end wall.
Davoust, Laurent; Achard, Jean-Luc; Drazek, Laurent
2015-02-01
This paper presents a new method for solving analytically the axisymmetric swirling flow generated in a finite annular channel from a rotating end wall, with no-slip boundary conditions along stationary side walls and a slip condition along the free surface opposite the rotating floor. In this case, the end-driven swirling flow can be described from the coupling between an azimuthal shear flow and a two-dimensional meridional flow driven by the centrifugal force along the rotating floor. A regular asymptotic expansion based on a small but finite Reynolds number is used to calculate centrifugation-induced first-order correction to the azimuthal Stokes flow obtained as the solution at leading order. For solving the first-order problem, the use of an integral boundary condition for the vorticity is found to be a convenient way to attribute boundary conditions in excess for the stream function to the vorticity. The annular geometry is characterized by both vertical and horizontal aspect ratios, whose respective influences on flow patterns are investigated. The vertical aspect ratio is found to involve nontrivial changes in flow patterns essentially due to the role of corner eddies located on the left and right sides of the rotating floor. The present analytical method can be ultimately extended to cylindrical geometries, irrespective of the surface opposite the rotating floor: a wall or a free surface. It can also serve as an analytical tool for monitoring confined rotating flows in applications related to surface viscosimetry or crystal growth from the melt.
IMPACT OF VAGINAL PARITY AND AGING ON THE ARCHITECTURAL DESIGN OF PELVIC FLOOR MUSCLES
Alperin, Marianna; Cook, Mark; Tuttle, Lori J.; Esparza, Mary C.; Lieber, Richard L.
2016-01-01
Background Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the PFM intrinsic structure due to childbirth and aging that lead to muscle dysfunction remain elusive. Objectives To determine the impact of vaginal deliveries and aging on human cadaveric PFM architecture, the strongest predictor of active muscle function. Study Design Coccygeus, iliococcygeus and pubovisceralis were obtained from younger, ≤ 51 years, vaginally nulliparous (N=5) and vaginally parous (N=6), and older, >51 years, vaginally nulliparous (N=6) and vaginally parous (N=6) donors without history of PFDs. Architectural parameters, predictive of muscle’s excursion and force-generating capacity, were determined using validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined using two-way ANOVA, with Tukey’s post-hoc testing with significance level of 0.05. Results The mean age of younger and older donors differed by ~40 years (P=0.001), but was similar between nulliparous and parous donors within each age group (P>0.9). Median parity was 2 (range 1–3) in younger and older vaginally parous groups, P=0.7. The main impact of parity was increased fiber length in the more proximal coccygeus (P=0.03), and iliococcygeus (P=0.04). Aging changes manifested as decreased physiological cross sectional area across all pelvic floor muscles, P<0.05, which substantially exceeded the age-related decline in muscle mass. Physiological cross sectional area was lower in younger vaginally parous, compared to younger vaginally nulliparous pelvic floor muscles, however the differences did not reach statistical significance. Pelvic floor muscles’ collagen content was not altered by parity, but increased dramatically with aging, P<0.05. Conclusions Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force generating capacity of all pelvic floor muscles in parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. PMID:26953079
ERIC Educational Resources Information Center
Watt, W. Bradford
2000-01-01
Discusses the use of seamless flooring in areas where cleanliness, waterproofing, and slip resistance is emphasized. Areas such as locker rooms, restrooms, kitchens and cafeterias, lobbies and hallways, multipurpose-rooms, and walkways are considered. (GR)
2014-04-03
CAPE CANAVERAL, Fla. – The Ground Systems Development and Operations Program is overseeing efforts to create a new multi-user firing room in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida. The main floor consoles, cabling and wires below the floor and ceiling tiles above have been removed. Sub-flooring has been installed and the room is marked off to create four separate rooms on the main floor. In view along the soffit are space shuttle launch plaques for 21 missions launched from Firing Room 4. The design of Firing Room 4 will incorporate five control room areas that are flexible to meet current and future NASA and commercial user requirements. The equipment and most of the consoles from Firing Room 4 were moved to Firing Room 2 for possible future reuse. Photo credit: NASA/Ben Smegelsky
Yan, Xu; Zhang, Xinwen; Chi, Weichao; Ai, Hongjun; Wu, Lin
2015-05-01
This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.
53. VIEW FROM FLOOR OF MAST TRENCH SHOWING BASE OF ...
53. VIEW FROM FLOOR OF MAST TRENCH SHOWING BASE OF ERECT UMBILICAL MAST. AIR-CONDITIONING DUCTS VISIBLE ON RIGHT SIDE OF MAST. HYDRAULIC ACTUATOR ARMS FOR OPENING TRENCH DOORS VISIBLE ON LEFT SIDE OF PHOTO. 'DOOR STOP' PEDESTAL IN FOREGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
New Whole-House Solutions Case Study: Schneider Homes, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2013-02-01
Schneider Homes cut energy use by 50% over the 2004 IECC on 28 homes built near Seattle in 2008. Schneider packed the walls with R-23 of blown fiberglass and blanketed the ceiling with R-38 of blown cellulose. Ducts went into conditioned space through open-web floor trusses between floors and air handlers went into an air sealed garage closet.
ERIC Educational Resources Information Center
Armstrong Cork Co., Lancaster, PA.
Survey information based on actual flooring installations in several types of buildings and traffic conditions, representing nearly 113 million square feet of actual user experience, is contained in this comprehensive report compiled by the Armstrong Cork Company. The comparative figures provided by these users clearly establish that--(1) the…
Laing, Andrew C; Robinovitch, Stephen N
2009-05-01
Low stiffness floors such as carpet appear to decrease hip fracture risk by providing a modest degree of force attenuation during falls without impairing balance. It is unknown whether other compliant floors can more effectively reduce impact loads without coincident increases in fall risk. We used a hip impact simulator to assess femoral neck force for four energy-absorbing floors (SmartCell, SofTile, Firm Foam, Soft Foam) compared to a rigid floor. We also assessed the influence of these floors on balance/mobility in 15 elderly women. We observed differences in the mean attenuation in peak femoral neck force provided by the SmartCell (24.5%), SofTile (47.2%), Firm Foam (76.6%), and Soft Foam (52.4%) floors. As impact velocity increased from 2 to 4m/s, force attenuation increased for SmartCell (from 17.3% to 33.7%) and SofTile (from 44.9% to 51.2%), but decreased for the Firm Foam (from 87.0% to 64.5%) and Soft Foam (from 66.1% to 37.9%) conditions. Regarding balance, there were no significant differences between the rigid, SmartCell, and SofTile floors in proportion of successful trials, Get Up and Go time, balance confidence or utility ratings. SofTile, Firm Foam, and Soft Foam caused significant increases (when compared to the rigid floor) in postural sway in the anterior-posterior and medial-lateral directions during standing. However, SmartCell increased sway only in the anterior-posterior direction. This study demonstrates that two commercially available compliant floors can attenuate femoral impact force by up to 50% while having only limited influence on balance in older women, and supports development of clinical trials to test their effectiveness in high-risk settings.
Influence of sports flooring and shoes on impact forces and performance during jump tasks.
Malisoux, Laurent; Gette, Paul; Urhausen, Axel; Bomfim, Joao; Theisen, Daniel
2017-01-01
We aim to determine the influence of sports floorings and sports shoes on impact mechanics and performance during standardised jump tasks. Twenty-one male volunteers performed ankle jumps (four consecutive maximal bounds with very dynamic ankle movements) and multi-jumps (two consecutive maximal counter-movement jumps) on force plates using minimalist and cushioned shoes under 5 sports flooring (SF) conditions. The shock absorption properties of the SF, defined as the proportion of peak impact force absorbed by the tested flooring when compared with a concrete hard surface, were: SF0 = 0% (no flooring), SF1 = 19%, SF2 = 26%, SF3 = 37% and SF4 = 45%. Shoe and flooring effects were compared using 2x5 repeated-measures ANOVA with post-hoc Bonferroni-corrected comparisons. A significant interaction between SF and shoe conditions was found for VILR only (p = 0.003). In minimalist shoes, SF influenced Vertical Instantaneous Loading Rate (VILR) during ankle jumps (p = 0.006) and multi-jumps (p<0.001), in accordance with shock absorption properties. However, in cushioned shoes, SF influenced VILR during ankle jumps only (p<0.001). Contact Time was the only additional variable affected by SF, but only during multi-jumps in minimalist shoes (p = 0.037). Cushioned shoes induced lower VILR (p<0.001) and lower Contact Time (p≤0.002) during ankle jumps and multi-jumps compared to minimalist shoes. During ankle jumps, cushioned shoes induced greater Peak Vertical Ground Reaction Force (PVGRF, p = 0.002), greater Vertical Average Loading Rate (p<0.001), and lower eccentric (p = 0.008) and concentric (p = 0.004) work. During multi-jumps, PVGRF was lower (p<0.001) and jump height was higher (p<0.001) in cushioned compared to minimalist shoes. In conclusion, cushioning influenced impact forces during standardised jump tasks, whether it was provided by the shoes or the sports flooring. VILR is the variable that was the most affected.
Influence of sports flooring and shoes on impact forces and performance during jump tasks
Urhausen, Axel; Bomfim, Joao
2017-01-01
We aim to determine the influence of sports floorings and sports shoes on impact mechanics and performance during standardised jump tasks. Twenty-one male volunteers performed ankle jumps (four consecutive maximal bounds with very dynamic ankle movements) and multi-jumps (two consecutive maximal counter-movement jumps) on force plates using minimalist and cushioned shoes under 5 sports flooring (SF) conditions. The shock absorption properties of the SF, defined as the proportion of peak impact force absorbed by the tested flooring when compared with a concrete hard surface, were: SF0 = 0% (no flooring), SF1 = 19%, SF2 = 26%, SF3 = 37% and SF4 = 45%. Shoe and flooring effects were compared using 2x5 repeated-measures ANOVA with post-hoc Bonferroni-corrected comparisons. A significant interaction between SF and shoe conditions was found for VILR only (p = 0.003). In minimalist shoes, SF influenced Vertical Instantaneous Loading Rate (VILR) during ankle jumps (p = 0.006) and multi-jumps (p<0.001), in accordance with shock absorption properties. However, in cushioned shoes, SF influenced VILR during ankle jumps only (p<0.001). Contact Time was the only additional variable affected by SF, but only during multi-jumps in minimalist shoes (p = 0.037). Cushioned shoes induced lower VILR (p<0.001) and lower Contact Time (p≤0.002) during ankle jumps and multi-jumps compared to minimalist shoes. During ankle jumps, cushioned shoes induced greater Peak Vertical Ground Reaction Force (PVGRF, p = 0.002), greater Vertical Average Loading Rate (p<0.001), and lower eccentric (p = 0.008) and concentric (p = 0.004) work. During multi-jumps, PVGRF was lower (p<0.001) and jump height was higher (p<0.001) in cushioned compared to minimalist shoes. In conclusion, cushioning influenced impact forces during standardised jump tasks, whether it was provided by the shoes or the sports flooring. VILR is the variable that was the most affected. PMID:29020108
32. INTERIOR VIEW TO THE NORTH OF THE FIRST FLOOR ...
32. INTERIOR VIEW TO THE NORTH OF THE FIRST FLOOR EAST CORRIDOR AND VIEWING GALLERY TO THE DISASSEMBLY BAY. A VIEWING AND WORK STATION FOR THE EAST SIDE OF THE UPPER LEVEL OF THE DISASSEMBLY BAY IS ON THE WEST SIDE OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
Instrumentation and control building, architectural, floor plans. Specifications no. Eng-04-353-55-72; Drawing No. 60-09-12' sheet 64 of 148; file no. 1321/15. Stamped: record drawing - as constructed. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA
A Novel Group Coordination Protocol for Collaborative Multimedia Systems
1998-01-01
technology have advanced considerably, ef- ficient group coordination support for applications characterized by synchronous and wide-area groupwork is...As a component within a general coordination architecture for many-to-many groupwork , floor control coexists with proto- cols for reliable ordered...multicast and media synchronization at a sub-application level. Orchestration of multiparty groupwork with fine-grained and fair floor control is an
A&M. TAN633. Hot cell floor plans, elevations, sections. Hole schedule ...
A&M. TAN-633. Hot cell floor plans, elevations, sections. Hole schedule (penetrations through concrete). Swing-door details. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-3. Date: December 1956. Approved by INEEL Classification Office for public release. INNEL index code no. 034-0633-00-693-107317 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR HEAT EXCHANGER BUILDING, TRA644. FLOOR PLAN AND SECTIONS. PUMP ...
ETR HEAT EXCHANGER BUILDING, TRA-644. FLOOR PLAN AND SECTIONS. PUMP CUBICLES WITH PUMP MOTORS OUTSIDE CUBICLES. HEAT EXCHANGER EQUIPMENT. COOLANT PIPE TUNNEL ENTERS FROM REACTOR BUILDING. KAISER ETR-5582-MTR-644-A-3, 2/1956. INL INDEX NO. 532-0644-00-486-101294, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LPT. Shield test facility (TAN646). Floor plan for water treatment ...
LPT. Shield test facility (TAN-646). Floor plan for water treatment room on west facade, tank and filter locations in basement along service tunnel and in coupling station. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-2. April 1957. INEEL Index code no. 037-0645/0646-51-693-107387 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
MTR, TRA603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL ...
MTR, TRA-603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL PARTITIONS ON EAST SIDE OF INSTRUMENT ROOM. DETAIL OF COLUMN ENCASEMENTS. STAIRWAYS IN NORTH AND SOUTH CORNERS. PASSENGER ELEVATION. BLAW-KNOX 3150-803-3, 7/1950. INL INDEX NO. 531-0603-00-098-100562, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
High Frequency Acoustic Reflection and Transmission in Ocean Sediments
2003-09-30
Development of a physical model of high-frequency acoustic interaction with the ocean floor, including penetration through and reflection from smooth and...experiments and additional laboratory measurements in the ARL:UT sand tank, an improved model of sediment acoustics will be developed that is...distinct areas of concentration: development of a broadband the oretical model to describe the acoustic interaction with the ocean floor in littoral
Daniel J. Porter; John O. Sawyer
2007-01-01
We characterized the volume, weight and top surface area of naturally fallen logs in an old-growth redwood forest, and quantified conifer recruit densities on these logs and on the surrounding forest floor. We report significantly greater conifer recruit densities on log substrates as compared to the forest floor. Log substrate availability was calculated on a per...
General view, kitchen and living/dining area of secondfloor apartment, east ...
General view, kitchen and living/dining area of second-floor apartment, east wing, looking southeast. - Lazaretto Quarantine Station, Wanamaker Avenue and East Second Street, Essington, Delaware County, PA
Improved repeatability of nasal potential difference with a larger surface catheter.
Vermeulen, François; Proesmans, Marijke; Boon, Mieke; De Boeck, Kris
2015-05-01
To increase the power of nasal potential difference (NPD) as a biomarker of CFTR function, improvement of its repeatability is needed. We evaluated the improvement in repeatability resulting from measuring NPD (1) over a larger surface area and (2) at a fixed location. To assess repeatability, NPD was measured on two occasions with a new method using a larger surface catheter at fixed locations on the nasal floor (LSC-floor(5cm) and LSC-floor(3cm)) or at the most negative basal potential (LSC-floor(max)); with a sidehole catheter on the nasal floor at 5 cm) from the nasal margin (SHC-floor(5cm)) or at the most negative potential (SHC-floor(max)); and with an endhole catheter below the inferior surface of the lower turbinate at the most negative potential (EHC-turb(max)). The within-subject standard deviation (S(w)) for repeated measurements of the total chloride response in the controls was smallest with the LSC-floor at a fixed location (LSC-floor(5cm) 3.1 mV; 95% CI 2.3-4.6 mV) and highest with the SHC-floor (SHC-floor(max) 14.6 mV; 95% CI 10.9-22.2 mV) or the EHC-turbinate (EHC-turb(max) 12.5 mV; 95% CI 10.7-23.0 mV) at the most negative basal potential. Measuring with the LSC-floor at the maximal potential increased the Sw (LSC-floor(max) 8.8 mV, 95% CI 6.0-16.1 mV, p=0.009 vs LSC-floor(5cm)), while measuring with the SHC-floor at a fixed location slightly decreased the Sw (SHC-floor(5cm) 9.8 mV, 95% CI 8.9-20.6 mV, p=0.06 vs SHC-floor(max)). In patients with cystic fibrosis, the S(w) was comparable, between 2.2 mV and 4.3 mV. Sample size calculations for trials using NPD to assess changes in ion transport showed that the number of subjects to be included could be approximately halved measuring with the larger surface catheter at a fixed location vs SHC or EHC at fixed locations. Measuring the NPD at a fixed location and over a larger surface resulted in increased repeatability and thereby also power as a biomarker of CFTR modulation. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Zhang, Pei-Feng; Hu, Yuan-Man; Xiong, Zai-Ping; Liu, Miao
2011-02-01
Based on the 1:10000 aerial photo in 1997 and the three QuickBird images in 2002, 2005, and 2008, and by using Barista software and GIS and RS techniques, the three-dimensional information of the residential community in Tiexi District of Shenyang was extracted, and the variation pattern of the three-dimensional landscape in the district during its reconstruction in 1997-2008 and related affecting factors were analyzed with the indices, ie. road density, greening rate, average building height, building height standard deviation, building coverage rate, floor area rate, building shape coefficient, population density, and per capita GDP. The results showed that in 1997-2008, the building area for industry decreased, that for commerce and other public affairs increased, and the area for residents, education, and medical cares basically remained stable. The building number, building coverage rate, and building shape coefficient decreased, while the floor area rate, average building height, height standard deviation, road density, and greening rate increased. Within the limited space of residential community, the containing capacity of population and economic activity increased, and the environment quality also improved to some extent. The variation degree of average building height increased, but the building energy consumption decreased. Population growth and economic development had positive correlations with floor area rate, road density, and greening rate, but negative correlation with building coverage rate.
Sea-floor geology and character offshore of Rocky Point, New York
Poppe, L.J.; McMullen, K.Y.; Ackerman, S.D.; Blackwood, D.S.; Irwin, B.J.; Schaer, J.D.; Lewit, P.G.; Doran, E.F.
2010-01-01
The U.S. Geological Survey (USGS), the Connecticut Department of Environmental Protection, and the National Oceanic and Atmospheric Administration (NOAA) have been working cooperatively to interpret surficial sea-floor geology along the coast of the Northeastern United States. NOAA survey H11445 in eastern Long Island Sound, offshore of Plum Island, New York, covers an area of about 12 square kilometers. Multibeam bathymetry and sidescan-sonar imagery from the survey, as well as sediment and photographic data from 13 stations occupied during a USGS verification cruise are used to delineate sea-floor features and characterize the environment. Bathymetry gradually deepens offshore to over 100 meters in a depression in the northwest part of the study area and reaches 60 meters in Plum Gut, a channel between Plum Island and Orient Point. Sand waves are present on a shoal north of Plum Island and in several smaller areas around the basin. Sand-wave asymmetry indicates that counter-clockwise net sediment transport maintains the shoal. Sand is prevalent where there is low backscatter in the sidescan-sonar imagery. Gravel and boulder areas are submerged lag deposits produced from the Harbor Hill-Orient Point-Fishers Island moraine segment and are found adjacent to the shorelines and just north of Plum Island, where high backscatter is present in the sidescan-sonar imagery.
Dive report: Alvin dive #1461; September 28, 1984 (JD 272); Plume site, southern Juan de Fuca Rift
Holcomb, R.T.; Kappel, Ellen S.; Ross, Stephanie L.
1987-01-01
Dive 1461 was the seventh of nine dives during a sea-going field program to investigate hydrothermal activity along the crest of the southern Juan de Fuca Ridge. During this dive on the Plume site, ALVIN crossed the western floor of the axial valley and traversed about 300 ra of the rim and floor of the narrow inner cleft. Hydrotherraal vents were observed only along the east wall of the inner cleft, and venting was concentrated in a single area less than 50 ra long near the base of that wall. The principal vents extended up the wall from the floor of the cleft to a height of about 10 m. Deposits of hydrothermal minerals occur as incrustations and chimneys on the floor and wall of the cleft. Associated with the hydrothermal vents is a community of vent organisms dominated by vestimentiferan worms and fluffy materials of uncertain nature. The inner cleft at the Plume Site is about 60 ra wide and 15-30 m deep. It has a simple U-shaped profile north of the active vent area, but to the south it contains at least one high, narrow ridge which converges with the east wall of the cleft at the site of hydrothermal venting. This area was also the site of a volcanic eruption, which occurred sometime earlier. Like many similar but subaerial examples, this eruption was episodic, but the cause of its interruptions is not yet known. The present hydrotherraal activity appears to be a residual effect of that last eruption, and the rate of hydrothermal deposition will probably decline in this area until another eruption occurs.
Mayne, Darren J; Morgan, Geoffrey G; Willmore, Alan; Rose, Nectarios; Jalaludin, Bin; Bambrick, Hilary; Bauman, Adrian
2013-12-24
Walkability describes the capacity of the built environment to support walking for various purposes. This paper describes the construction and validation of two objective walkability indexes for Sydney, Australia. Walkability indexes using residential density, intersection density, land use mix, with and without retail floor area ratio were calculated for 5,858 Sydney Census Collection Districts in a geographical information system. Associations between variables were evaluated using Spearman's rho (ρ). Internal consistency and factor structure of indexes were estimated with Cronbach's alpha and principal components analysis; convergent and predictive validity were measured using weighted kappa (κw) and by comparison with reported walking to work at the 2006 Australian Census using logistic regression. Spatial variation in walkability was assessed using choropleth maps and Moran's I. A three-attribute abridged Sydney Walkability Index comprising residential density, intersection density and land use mix was constructed for all Sydney as retail floor area was only available for 5.3% of Census Collection Districts. A four-attribute full index including retail floor area ratio was calculated for 263 Census Collection Districts in the Sydney Central Business District. Abridged and full walkability index scores for these 263 areas were strongly correlated (ρ=0.93) and there was good agreement between walkability quartiles (κw=0.73). Internal consistency ranged from 0.60 to 0.71, and all index variables loaded highly on a single factor. The percentage of employed persons who walked to work increased with increasing walkability: 3.0% in low income-low walkability areas versus 7.9% in low income-high walkability areas; and 2.1% in high income-low walkability areas versus 11% in high income-high walkability areas. The adjusted odds of walking to work were 1.05 (0.96-1.15), 1.58 (1.45-1.71) and 3.02 (2.76-3.30) times higher in medium, high and very high compared to low walkability areas. Associations were similar for full and abridged indexes. The abridged Sydney Walkability Index has predictive validity for utilitarian walking, will inform urban planning in Sydney, and will be used as an objective measure of neighbourhood walkability in a large population cohort. Abridged walkability indexes may be useful in settings where retail floor area data are unavailable.
2013-01-01
Background Walkability describes the capacity of the built environment to support walking for various purposes. This paper describes the construction and validation of two objective walkability indexes for Sydney, Australia. Methods Walkability indexes using residential density, intersection density, land use mix, with and without retail floor area ratio were calculated for 5,858 Sydney Census Collection Districts in a geographical information system. Associations between variables were evaluated using Spearman’s rho (ρ). Internal consistency and factor structure of indexes were estimated with Cronbach’s alpha and principal components analysis; convergent and predictive validity were measured using weighted kappa (κw) and by comparison with reported walking to work at the 2006 Australian Census using logistic regression. Spatial variation in walkability was assessed using choropleth maps and Moran’s I. Results A three-attribute abridged Sydney Walkability Index comprising residential density, intersection density and land use mix was constructed for all Sydney as retail floor area was only available for 5.3% of Census Collection Districts. A four-attribute full index including retail floor area ratio was calculated for 263 Census Collection Districts in the Sydney Central Business District. Abridged and full walkability index scores for these 263 areas were strongly correlated (ρ=0.93) and there was good agreement between walkability quartiles (κw=0.73). Internal consistency ranged from 0.60 to 0.71, and all index variables loaded highly on a single factor. The percentage of employed persons who walked to work increased with increasing walkability: 3.0% in low income-low walkability areas versus 7.9% in low income-high walkability areas; and 2.1% in high income-low walkability areas versus 11% in high income-high walkability areas. The adjusted odds of walking to work were 1.05 (0.96–1.15), 1.58 (1.45–1.71) and 3.02 (2.76–3.30) times higher in medium, high and very high compared to low walkability areas. Associations were similar for full and abridged indexes. Conclusions The abridged Sydney Walkability Index has predictive validity for utilitarian walking, will inform urban planning in Sydney, and will be used as an objective measure of neighbourhood walkability in a large population cohort. Abridged walkability indexes may be useful in settings where retail floor area data are unavailable. PMID:24365133
Exercise Equipment Usability Assessment for a Deep Space Concept Vehicle
NASA Technical Reports Server (NTRS)
Rhodes, Brooke M.; Reynolds, David W.
2015-01-01
With international aspirations to send astronauts to deep space, the world is now faced with the complex problem of keeping astronauts healthy in unexplored hostile environments for durations of time never before attempted by humans. The great physical demands imparted by space exploration compound the problem of astronaut health, as the astronauts must not only be healthy, but physically fit upon destination arrival in order to perform the scientific tasks required of them. Additionally, future deep space exploration necessitates the development of environments conducive to long-duration habitation that would supplement propulsive vehicles. Space Launch System (SLS) core stage barrel sections present large volumes of robust structure that can be recycled and used for long duration habitation. This assessment will focus on one such conceptual craft, referred to as the SLS Derived Habitat (SLS-DH). Marshall Space Flight Center's (MSFC) Advanced Concepts Office (ACO) has formulated a high-level layout of this SLS-DH with parameters such as floor number and orientation, floor designations, grid dimensions, wall placement, etc. Yet to be determined, however, is the layout of the exercise area. Currently the SLS-DH features three floors laid out longitudinally, leaving 2m of height between the floor and ceilings. This short distance between levels introduces challenges for proper placement of exercise equipment such as treadmills and stationary bicycles, as the dynamic envelope for the 95th percentile male astronauts is greater than 2m. This study aims to assess the optimal equipment layout and sizing for the exercise area of this habitat. Figure 1 illustrates the layout of the DSH concept demonstrator located at MSFC. The exercise area is located on the lower level, seen here as the front half of the level occupied by a crew member. This small volume does not allow for numerous or bulky exercise machines, so the conceptual equipment has been limited to a treadmill and stationary bicycle. With the most current treadmill aboard the International Space Station (ISS), the Combined Operational Load-Bearing External Resistance Treadmill (COLBERT), being located in an International Standard Payload Rack (ISPR), the bottom of the conceptual treadmill features a height of 38in. Making the treadmill flush with the floor would be impossible in this rack configuration, as the distance from the outer wall of the spacecraft to the bottom floor would be too shallow. From preliminary sizing, the 38in required for the bottom of the treadmill combined with a 78in operational envelope for a 95th percentile may not be accommodated in the exercise area in a vertical orientation. Figure 2 demonstrates the volume required (in maroon) for an ISPR-bound treadmill in the concept demonstrator. Early indications as seen in this figure indicate that the crew members would contact the ceiling in such an arrangement. An assessment will be conducted to evaluate various orientations of exercise equipment in the concept demonstrator. Orientations to be tested include putting the bottom of the treadmill on the wall, having the treadmill at an angle in the floor both horizontally and vertically, and having a shorter (non-rack bound) treadmill in a vertical orientation on the floor. This assessment will yield findings regarding sizing of the area and how well participants feel they could exercise in such an environment. Due to the restrictions of assessing a microgravity vehicle in a normal-gravity environment, simulations in MSFC's Virtual Environments Lab (VEL) may be necessary. Final deliverables will include recommendations regarding the location and size of possible exercise equipment aboard the SLS-Derived DSH.
Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, D.; Kono, J.; Vieira, R.
During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less
NASA Astrophysics Data System (ADS)
Ohkawa, S.; Hiruta, A.; Yanagimoto, Y.; Matsumoto, R.; Asakawa, E.
2016-12-01
To delineate the detailed structure of the gas chimneys, a high-resolution three-dimensional seismic survey (HR3D) was carried out in Joetsu area, at the southeastern margin of Japan Sea where hydrate-related mound and pockmark systems with gas chimneys are widely developed. HR3D data have successfully revealed the fine structure of gas chimneys which were not clearly imaged by the existing seismic data, such as sub-bottom profilers and conventional large-scale 3D surveys for petroleum exploration. HR3D data are also useful to interpolate and extrapolate spatially the geological/geophysical information obtained at wells most of which were drilled into the gas hydrate concentrated zones (GHCZs.) In the areas of low hydrate concentration, the reflections show a parallel-stratified pattern and the bottom simulating reflector (BSR) is parallel to the sea floor reflections. On the other hand, GHCZs are seismologically characterized by (1) strong sea floor reflections on the chimney mounds, (2) chaotic reflection patterns in the chimneys, and (3) pull-up of bottom simulating reflector (BSR) as shown in the attached figure. Strong sea floor reflections suggest that solid hydrates deposit in the very shallow part beneath the sea floor and the chaotic reflections indicate the hydrates are not continuously layered but interspersedly distributed. The BSR pull-up phenomena as much as 70 80msec are caused by high-velocity materials existing between the sea floor and the BSR. The sonic logs acquired by LWD at wells drilled into GHCZs show high velocity up to 3,800 m/s in the massive hydrates. The pull-up times estimated from the sonic data are consistent in general with the observed pull-up times on HR3D sections, suggesting the pull-up times could be useful for a preliminary evaluation of hydrate zones before drilling and/or in the areas without well data. This study was conducted under the commission from AIST as a part of the methane hydrate research project funded by METI (the Ministry of Economy, Trade and Industry, Japan.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, D.; Kono, J.; Vieira, R.
During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less
Housing and Wood Products Assessment.
1982-12-10
1981 to a peak of of floor area, the North Central almost 3 million in 1972 when region 1,670 square feet, the government subsidy programs were South...other masonry alterations. lumber by plywood. Lumber has Interior decorative panel already been effectively elimina- products are also used widely in...possible savings in walls . already been effectively elimi- is 25 percent and 40 percent on nated in these markets and future roofs. Wood joist floor
76 FR 36014 - Proposed Amendment of Class C Airspace; Palm Beach International Airport, FL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-21
... Park Airport (LNA) from 1,200 feet MSL to 1,600 feet MSL. The FAA is proposing this action to enhance... floor of Class C airspace to 1,600 feet MSL within an area overlying, and to the south of, the Palm... of LNA is at 1,200 feet MSL. Raising the Class C floor as proposed would enhance safety by providing...
HEALTH AND SAFETY BUILDING, TRA667. SOUTH AND WEST ELEVATIONS. FLOOR ...
HEALTH AND SAFETY BUILDING, TRA-667. SOUTH AND WEST ELEVATIONS. FLOOR PLAN AND ROOM DESIGNATIONS. NOTE PAIR OF ENTRY DOORS IN WEST ELEVATION FOR MEN AND WOMEN. CONCRETE T-BEAMS. F.C. TORKELSON CO. 842-MTR-667-A1, 1/1963. INL INDEX NO. 531-0667-00-851-151143, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ON GROUND FLOOR, CAMERA LOOKS SOUTHWEST INTO PIT. ...
ETR, TRA-642. ON GROUND FLOOR, CAMERA LOOKS SOUTHWEST INTO PIT. CANAL STRUCTURE IS AT RIGHT OF CENTER WITH RECTANGULAR OPENING TO BE MATED WITH THE DE-FUELING MECHANISM THAT WILL DEPOSIT FUEL RODS INTO THE WORKING CANAL. INL NEGATIVE NO. 56-3710. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. TAN607 third floor plan for hot shop. Crane control ...
A&M. TAN-607 third floor plan for hot shop. Crane control rooms and their shielding windows. Plenum. Wall rack for manipulators in hot shop. Ralph M. Parsons 902-3-ANP-607-A 103. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106755 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
46. NORTH END OF MILL NO. 2, 1st FLOOR, BELOW ...
46. NORTH END OF MILL NO. 2, 1st FLOOR, BELOW PICKER AND CLOTH ROOM AREA. FUNCTION OF THIS SPACE UNKNOWN AT PRESENT. NOTE THAT EYE BEAM REPLACES ORIGINAL WALL OF 1892 PICKER HOUSE. CENTER (OR LEFT) DOOR IS ENTRY TO MILL NO. 2. RIGHT DOOR IS ENTRY TO 1892 NAPPER ROOM. - Prattville Manufacturing Company, Number One, 242 South Court Street, Prattville, Autauga County, AL
4. Interior of second floor of Dixie Cotton Mill, view ...
4. Interior of second floor of Dixie Cotton Mill, view facing west. This area is now designated the upstairs yarn storage room. Note the change of column type and roof structure from the first to second column in foreground of photograph. The round columns were used in the 1913 addition to the original 1895 structure. - Dixie Cotton Mill, 710 Greenville Street, La Grange, Troup County, GA
8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...
8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
6. Photographic copy of blueprint dated 1929; Henschien & McLaren, ...
6. Photographic copy of blueprint dated 1929; Henschien & McLaren, Chicago, architects; Original in collection of Rath drawings and blueprints owned by Waterloo Community Development Board, Waterloo, Iowa; PLAN OF KILLING FLOOR IN 1929 BEEF HOUSE; CATTLE WERE SKINNED ON THE FLOOR IN PRITCHING AREA NEAR CENTER OF DRAWING - Rath Packing Company, Cooler Building-1929 Beef House, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
PROCESS WATER BUILDING, TRA605. SECTIONS B, C AND D SHOW ...
PROCESS WATER BUILDING, TRA-605. SECTIONS B, C AND D SHOW RELATIONSHIP BETWEEN FLASH EVAPORATORS (ABOVE) AND SEAL AND SUMP TANKS (BELOW). BASEMENT FLOOR IS BELOW GRADE; FIRST FLOOR, ABOVE GRADE. SHIELDING TOLERANCES. BLAW-KNOX 3150-5-7, 8/1950. INL INDEX NO. 531-605-00-098-100012, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Robert Woolsey; Thomas M. McGee; Carol Blanton Lutken
2007-03-31
The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances,more » necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 (MC118) in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. These delays caused scheduling and deployments difficulties but many sensors and instruments were completed during this period. Software has been written that will accommodate the data that the station retrieves, when it begins to be delivered. In addition, new seismic data processing software has been written to treat the peculiar data to be received by the vertical line array (VLA) and additional software has been developed that will address the horizontal line array (HLA) data. These packages have been tested on data from the test deployments of the VLA and on data from other, similar, areas of the Gulf (in the case of the HLA software). The CMRET has conducted one very significant research cruise during this reporting period: a March cruise to perform sea trials of the Station Service Device (SSD), the custom Remotely Operated Vehicle (ROV) built to perform several of the unique functions required for the observatory to become fully operational. March's efforts included test deployments of the SSD and Florida Southern University's mass spectrometer designed to measure hydrocarbon gases in the water column and The University of Georgia's microbial collector. The University of Georgia's rotational sea-floor camera was retrieved as was Specialty Devices storm monitor array. The former was deployed in September and the latter in June, 2006. Both were retrieved by acoustic release from a dispensable weight. Cruise participants also went prepared to recover any and all instruments left on the sea-floor during the September Johnson SeaLink submersible cruise. One of the pore-fluid samplers, a small ''peeper'' was retrieved successfully and in fine condition. Other instrumentation was left on the sea-floor until modifications of the SSD are complete and a return cruise is accomplished.« less
NASA Astrophysics Data System (ADS)
Bagley, P. M.; Bradley, S.; Priede, I. G.; Gray, P.
1999-12-01
Most research on animal behaviour in the deep ocean (to depths of 6000 m) is restricted to the capture of dead specimens or viewing activity over small areas of the sea floor by means of cameras or submersibles. This paper describes the use of a miniature acoustic code-activated transponder (CAT) tag and short base-line sonar to track the movements of deep-sea fish in two dimensions over an area 1 km in diameter centred on a lander platform. The CAT tags and sonar are transported to the deep-sea floor by means of a subsea mooring which is ballasted so that it lands and remains on the sea floor for the duration of the tracking experiment (the lander). A description of the CAT, lander and short base-line sonar is given. Results are presented to illustrate the operation of the system.
20. VIEW OF THE RECORDS STORAGE AREA LOCATED ON THE ...
20. VIEW OF THE RECORDS STORAGE AREA LOCATED ON THE FIRST FLOOR MEZZANINE. (1/83) - Rocky Flats Plant, General Manufacturing, Support, Records-Central Computing, Southern portion of Plant, Golden, Jefferson County, CO
Bottom morphology in the Song Hau distributary channel, Mekong River Delta, Vietnam
NASA Astrophysics Data System (ADS)
Allison, Mead A.; Dallon Weathers, H.; Meselhe, Ehab A.
2017-09-01
Field studies in the Song Hau distributary of the Mekong Delta in Vietnam conducted at high (Sept.-Oct 2014) and low (March 2015) Mekong River discharge are utilized to examine channel bottom morphology and links with sediment transport in the system. Multibeam bathymetric mapping surveys over the entire channel complex in the lower 80 km of the distributary channel, and over 12- to 24-h tidal periods at six transect locations in the reach are used to characterize bottom type and change on seasonal and tidal timescales, supplemented by bottom sampling. The results of this study indicate that the largest proportion of channel floor (up to 80% of the total area) is composed of substratum outcrops of relict sediment units deposited during the progradation of the delta in the last 3.5 ka. These take the form of outcrops that are either (1) steep-sided, tabular channel floor, (2) steep-sided sidewall, or (3) relatively flat channel floor. Flatter outcrops of channel floor substratum are identified by the presence of sedimentary furrows (<0.5 m deep) incised into the channel bottom that are exposed at high discharge and oriented along channel and laterally continuous for kilometers. These furrows are persistent in location and extent across tidal cycles and appear to be incised into relict units, sometimes with a thin surficial layer of modern sediment observable in bottom grabs. The extent of substratum exposure, greater than that observed previously in low tidal energy systems like the Mississippi River, may relate both to a relatively low sand supply from the catchment, and/or to an efficient transfer of both sand and mud through this tidally energetic channel. Sand bottom areas forming dunes, comprise about 19% of the channel floor over the study area and are generally less than a few meters thick except on bar extensions of mid-channel islands. Both sandy and substratum areas are mantled by soft muds 0.25-1 m thick during low discharge in the estuarine section of the study area. This mud mantling appears to be a key control on bottom sourcing of sand to suspension. An understanding of channel bottom morphology, particularly mobility and erodibility of sediments, is valuable for setting up morphodynamic models of channel evolution that can be used to test system response to anthropogenic alterations in the catchment and rising sea levels.
Bergsten, Christer; Telezhenko, Evgenij; Ventorp, Michael
2015-01-01
Simple Summary In this study the effect of different flooring systems on locomotion, claw conformation, loading, claw- and leg disorders was assessed in heifers from one year before to one year after calving. After calving, heifers kept on alleys covered with rubber flooring were found to develop less lameness, fewer claw disorders of the sole horn and fewer leg lesions than those kept on concrete alleys. Recruitment heifers reared on soft deep straw bedding had fewer sole horn lesions and more overgrown claws before calving, but were more prone to severe sole horn lesions after calving, than those reared in cubicles with hard concrete floors. Abstract Claw health, an important dairy cow welfare parameter, may be affected by early-life foot/leg stresses. To investigate this, groups of pregnant heifers were allocated to deep straw bedding (Soft) or cubicles (Hard), both with scraped concrete feeding alleys. After the grazing season, they were re-housed in cubicle systems, half on slatted concrete (Hard) and half on slatted rubber (Soft) alleys. Claw measurements, contact area and pressure distribution claw/flooring, claw disorders and leg lesions were recorded at the start and end of each housing season. Locomotion and leg lesions were also scored monthly after calving. Prevalence of sole haemorrhages was higher among pregnant heifers in cubicles than in deep straw. After calving, first-calvers on Hard floors had higher odds for lameness (OR = 3.6; p < 0.01), sole haemorrhages/ulcers (OR = 2.2; p < 0.05), white-line haemorrhages (OR = 2.8; p < 0.01) and leg lesions (OR = 2.6; p < 0.02) than those on Soft floors. Lowest prevalence and severity of sole and white-line haemorrhages (non-significant) in first-calvers was found in those on Soft floors and reared on Hard floors and the highest prevalence and severity on those on Hard floors reared on Soft floors. Soft flooring after calving is of most importance for healthy feet and legs. PMID:26479380
The slip resistance of common footwear materials measured with two slipmeters.
Chang, W R; Matz, S
2001-12-01
The slip resistance of 16 commonly used footwear materials was measured with the Brungraber Mark II and the English XL on 3 floor surfaces under surface conditions of dry, wet, oily and oily wet. Three samples were used for each material combination and surface condition. The results of a one way ANOVA analysis indicated that the differences among different samples were statistically significant for a large number of material combinations and surface conditions. The results indicated that the ranking of materials based on their slip resistance values depends highly on the slipmeters, floor surfaces and surface conditions. For contaminated surfaces including wet, oily and oily wet surfaces, the slip resistance obtained with the English XL was usually higher than that measured with the Brungraber Mark II. The correlation coefficients between the slip resistance obtained with these two slipmeters calculated for different surface conditions indicated a strong correlation with statistical significance.
Laying hen movement in a commercial aviary: Enclosure to floor and back again.
Campbell, D L M; Makagon, M M; Swanson, J C; Siegford, J M
2016-01-01
Many producers in the laying hen industry, including in North America, are phasing out conventional cages in response to consumer demands and sometimes subsequent legislation. Alternative housing systems such as aviaries are being implemented in an attempt to improve hen welfare. Aviaries provide additional space and resources to groups of hens, including a litter area on the floor. However, little is known about hen movement between tiered enclosures and floor litter areas in aviary systems. Diurnal rhythms and social attraction may result in peak times of movement that could lead to overcrowding of areas, or alternatively hen preferences may lead to some areas not being fully utilized. We monitored hen movement between tiered enclosures and litter areas, including movement on and off the outer perch, across the day at peak, mid and end of lay in a commercial aviary. Hens moved onto and off of the open litter area across the day, transitioning between tiered enclosures, outer perches, open litter areas, and litter areas under tiered enclosures. At certain times of day, there were periods of greater hen movement down to the open litter area and between litter areas. For example, more hens were typically observed exiting enclosures, jumping from perches to open litter, and traveling between open litter and litter under tiered enclosures in the morning (all P ≤ 0.001). In all but one instance, more hens were observed on open litter areas in the afternoon than at other times of day (all P ≤ 0.029). However, hen re-entry to tiered enclosures showed less circadian patterning. Hen movement was observed between areas of interest at all sampled time periods, indicating hens use all areas of the system. Further research should examine whether all individual hens do move between areas equally, including within levels of the tiered enclosure, or if crowding occurs on the outer perches or in the litter during times of peak movement. © 2015 Poultry Science Association Inc.
Thompson, Katy-Anne; Paton, Susan; Pottage, Thomas; Bennett, Allan
2018-05-09
Four commercially available robotic vacuum cleaners were assessed for sampling efficiency of wet disseminated Bacillus atrophaeus spores on carpet, Polyvinyl Chloride (PVC) and laminate flooring. Furthermore, their operability was evaluated and decontamination efficiency of one robot was assessed using a sodium hypochlorite solution. In an environmental chamber, robots self-navigated around 4 m 2 of flooring containing a single contaminated 0.25 m 2 tile (ca. 10 4 spores per cm 2 ). Contamination levels at pre-determined locations were assessed by macrofoam swabs (PVC and laminate) or water soluble tape (carpet), before and after sampling. Robots were dismantled post-sampling and spore recoveries assessed. Aerosol contamination was also measured during sampling. Robot sampling efficiencies were variable, however, robots recovered most spores from laminate (up to 17.1%), then PVC, and lastly carpet. All robots spread contamination from the 'hotspot' (all robots spread < 0.6% of the contamination to other areas) and became surface contaminated. Spores were detected at low levels during air sampling (<5.6 spores l -1 ). Liquid decontamination inactivated 99.1% of spores from PVC. Robotic vacuum cleaners show promise for both sampling and initial decontamination of indoor flooring. In the event of a bioterror incident, e.g. deliberate release of Bacillus anthracis spores, areas require sampling to determine the magnitude and extent of contamination, and to establish decontamination efficacy. In this study we investigate robotic sampling methods against high concentrations of bacterial spores applied by wet deposition to different floorings, contamination spread to other areas, potential transfer of spores to the operators and assessment of a wet vacuum robot for spore inactivation. The robots' usability was evaluated and how they can be employed in real life scenarios. This will help to reduce the economic cost of sampling and the risk to sampling/decontamination teams. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Astrophysics Data System (ADS)
Vitasse, Yann; Klein, Geoffrey; Kirchner, James W.; Rebetez, Martine
2017-11-01
Some of the world's valleys are famous for having particularly cold microclimates. The La Brevine valley, in the Swiss Jura Mountains, holds the record for the lowest temperature ever measured in an inhabited location in Switzerland. We studied cold air pools (CAPs) in this valley during the winter of 2014-2015 using 44 temperature data loggers distributed between 1033 and 1293 m asl. Our goals were to (i) describe the climatic conditions under which CAPs form in the valley, (ii) examine the spatial configuration and the temperature structure of the CAPs and (iii) quantify how often temperature inversions occur in winter using long-term series of temperature from the valley floor. Our results show that CAPs occurred every second night, on average, during the winter of 2014-2015 and were typically formed under cloudless, windless and high-pressure conditions. Strong temperature inversions up to 28 °C were detected between the valley floor and the surrounding hills. The spatial temperature structure of the CAPs varies among the different inversion days, with the upper boundary of the cold pool generally situated at about 1150 m asl. Although mean temperatures have increased in this area over the period 1960-2015 in connection with climate change, the occurrences of extreme cold temperatures did not decrease in winter and are highly correlated with the North Atlantic Oscillation and the East Atlantic indices. This suggests that CAPs in sheltered valleys are largely decoupled from the free atmosphere temperature and will likely continue to occur in the next decades under warmer conditions.
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef
2016-01-01
Purpose Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. Methods A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. Results HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. Conclusions In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect. PMID:27126724
No Concentration Decrease of House Dust Mite Allergens With Rising Altitude in Alpine Regions.
Grafetstätter, Carina; Prossegger, Johanna; Braunschmid, Herbert; Sanovic, Renata; Hahne, Penelope; Pichler, Christina; Thalhamer, Josef; Hartl, Arnulf
2016-07-01
Several studies over the past 4 decades have indicated a significant reduction in house dust mite (HDM) and HDM allergen concentration in areas higher than 1,500 m above sea level. These have served as basis of allergen avoidance therapies for HDM allergy and asthma. However, modern construction techniques used in the insulation, heating, and glazing of buildings as well as global warming have changed the environmental parameters for HDM living conditions. The present study revisits the paradigm of decreasing HDM allergen concentrations with increasing altitude in the alpine region of Germany and Austria. A total of 122 dust samples from different abodes (hotels, privates and mountain huts) at different altitudes (400-2,600 m) were taken, and concentrations of HDM allergens were analyzed. Humidity and temperature conditions, and numerous indoor environmental parameters such as fine dust, type of flooring, age of building, and frequency of cleaning were determined. HDM allergen concentrations did not significantly change with increasing altitude or relative humidity. At the level of indoor parameters, correlations could be found for different flooring types and the concentration of HDM allergens. In contrast to the widespread view of the relationship between altitude and HDM allergen concentrations, clinically relevant concentrations of HDM allergens could be detected in high-lying alpine regions in Austria and Germany. These results indicate that improvement in conditions of asthmatic patients sensitized against HDMs during a stay at high altitude can no longer be ascribed to decreased levels of HDM allergens, instead, other mechanisms may trigger the beneficial effect.
Panman, Cmcr; Wiegersma, M; Kollen, B J; Berger, M Y; Lisman-Van Leeuwen, Y; Vermeulen, K M; Dekker, J H
2017-02-01
To compare effects and cost-effectiveness of pelvic floor muscle training (PFMT) and watchful waiting in women with pelvic organ prolapse. Randomised controlled trial. Dutch general practice. Women (≥55 years) with symptomatic mild prolapse, identified by screening. Linear multilevel analysis. Primary outcome was change of pelvic floor symptoms (Pelvic-Floor-Distress-Inventory-20 [PFDI-20]) during 24 months. Secondary outcomes were condition-specific and general quality of life, costs, sexual functioning, prolapse stage, pelvic floor muscle function and women's perceived improvement of symptoms. PFMT (n = 145) resulted in a 12.2-point (95% CI 7.2-17.2, P < 0.001) greater improvement in PFDI-20 score during 24 months compared with watchful waiting (n = 142). Participants randomised to PFMT more often reported improved symptoms (43% versus 14% for watchful waiting). Direct medical costs per person were €330 for PFMT and €91 for watchful waiting but costs for absorbent pads were lower in the PFMT group (€40 versus €77). Other secondary outcomes did not differ between groups. Post-hoc subgroup analysis demonstrated that PFMT was more effective in women experiencing higher pelvic floor symptom distress at baseline. PFMT resulted in greater pelvic floor symptom improvement compared with watchful waiting. The difference was statistically significant, but below the presumed level of clinical relevance (15 points). PFMT more often led to women's perceived improvement of symptoms, lower absorbent pads costs, and was more effective in women experiencing higher pelvic floor symptom distress. Therefore, PFMT could be advised in women with bothersome symptoms of mild prolapse. Pelvic floor muscle training can be effective in women with bothersome symptoms of mild prolapse. © 2016 Royal College of Obstetricians and Gynaecologists.
Mitchell, Carl P J; Kolka, Randall K; Fraver, Shawn
2012-08-07
A number of factors influence the amount of mercury (Hg) in forest floors and soils, including deposition, volatile emission, leaching, and disturbances such as fire. Currently the impact on soil Hg pools from other widespread forest disturbances such as blowdown and management practices like salvage logging are unknown. Moreover, ecological and biogeochemical responses to disturbances are generally investigated within a single-disturbance context, with little currently known about the impact of multiple disturbances occurring in rapid succession. In this study we capitalize on a combination of blowdown, salvage logging and fire events in the sub-boreal region of northern Minnesota to assess both the singular and combined effects of these disturbances on forest floor and soil total Hg concentrations and pools. Although none of the disturbance combinations affected Hg in mineral soil, we did observe significant effects on both Hg concentrations and pools in the forest floor. Blowdown increased the mean Hg pool in the forest floor by 0.76 mg Hg m(-2) (223%). Salvage logging following blowdown created conditions leading to a significantly more severe forest floor burn during wildfire, which significantly enhanced Hg emission. This sequence of combined events resulted in a mean loss of approximately 0.42 mg Hg m(-2) (68% of pool) from the forest floor, after conservatively accounting for potential losses via enhanced soil leaching and volatile emissions between the disturbance and sampling dates. Fire alone or blowdown followed by fire did not significantly affect the total Hg concentrations or pools in the forest floor. Overall, unexpected consequences for soil Hg accumulation and by extension, atmospheric Hg emission and risk to aquatic biota, may result when combined impacts are considered in addition to singular forest floor and soil disturbances.
PVC flooring is related to human uptake of phthalates in infants.
Carlstedt, F; Jönsson, B A G; Bornehag, C-G
2013-02-01
Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P < 0.007) and related to the body area of the infant. Levels of the DEHP metabolites MEHHP (P < 0.01) and MEOHP (P < 0.04) were higher in the 2-month-old infants who were not exclusively breast-fed when compared with breast-fed children. The findings indicate that the use of soft PVC as flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.
Transvaginal Pelvic Floor Muscle Injection Technique: A Cadaver Study.
Gupta, Priyanka; Ehlert, Michael; Sirls, Larry T; Peters, Kenneth
Women with pelvic floor dysfunction can have tender areas on vaginal examination, which can be treated with trigger-point injections. There are no publications to evaluate the accuracy of pelvic floor muscle injections. Trigger-point injections were performed on 2 fresh cadaveric pelvises using a curved nasal cannula guide and 7-in spinal needle. This was performed using our standard template of 2 sets of injections at the 1-, 3-, and 5-o'clock positions distally and proximally. The first pelvis was dissected to examine dye penetration. Based on these results, we modified our technique and repeated the injections on the second cadaver. We dissected the second pelvis and compared our findings. The 1-o'clock proximal and distal injections stained the obturator internus and externus near the insertion at the ischiopubic ramus. The 3-o'clock injections stained the midbody of the pubococcygeus and puborectalis. The distal 5-o'clock position was too deep and stained the fat of the ischiorectal space. The proximal 5-o'clock injection stained the area of the pudendal nerve. Our goal at the distal 5-o'clock position was to infuse the iliococcygeus muscle, so we shortened the needle depth from 2 to 1 cm beyond the cannula tip. In our second dissection, the distal 5-o'clock injection again stained only the fat of the ischiorectal space. This is the first study to characterize the distribution of pelvic floor muscle injections in a cadaver model and confirms the ability to deliver medications effectively to the pelvic floor muscles.
NASA Technical Reports Server (NTRS)
2004-01-01
5 May 2004 Most middle-latitude craters on Mars have strange landforms on their floors. Often, the floors have pitted and convoluted features that lack simple explanation. In this case, the central part of the crater floor shown in this 2004 Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image bears some resemblance to the folded nature of a brain. Or not. It depends upon the 'eye of the beholder,' perhaps. The light-toned 'ring' around the 'brain' feature is more easily explained--windblown ripples and dunes. The crater occurs near 33.1oS, 91.2oW, and is illuminated from the upper left. The picture covers an area about 3 km (1.9 mi) across.DOE Office of Scientific and Technical Information (OSTI.GOV)
Malhotra, Mini; New, Joshua Ryan; Im, Piljae
As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, andmore » jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses represent a majority of courthouse buildings. However, collectively they comprise a small fraction of total courthouse floor area in the US. Spaces and operation of courthouse also varies depending on the court type (federal court vs state court; district, appellate, versus Supreme Court) and jurisdiction (general jurisdiction, general jurisdiction trial, or special courts). Based on the statistics on courthouses, general jurisdiction trial court is considered for the prototype model. The model is assumed to be a 4-courtroom, small, 72,000 sqft three-story building including a ground level/ basement.« less
13. Interior view of food storage area looking towards hallway; ...
13. Interior view of food storage area looking towards hallway; southeast corner of building on lower floor; view to north. - Ellsworth Air Force Base, Mess & Administration Building, 1561 Ellsworth Street, Blackhawk, Meade County, SD
“Hotspots” for Aggression in Licensed Drinking Venues
Graham, Kathryn; Bernards, Sharon; Osgood, D. Wayne; Wells, Samantha
2011-01-01
Introduction and Aims In order to better understand the social context of barroom aggression, the aim was to identify common locations (“hotspots”) for aggression in bars and examine the association of hotspots with aggression severity and environmental characteristics. Design and Methods Aggression hotspots were identified using narrative descriptions and data recorded on premises’ floor plans for 1057 incidents of aggression collected in the Safer Bars evaluation. Hierarchical Linear Modeling was used to identify bar-level and night-level characteristics associated with each hotspot. Results The most common location for aggression was the dance floor (20.0% of incidents) or near the dance floor (11.5%), followed by near the serving bar (15.7%), at tables (13.1%), aisles, hallways and other areas of movement (6.2%), entrance (4.5%) and the pool playing area (4.1%). Hotspots were predicted mainly by bar-level characteristics, with dance floor aggression associated with crowded bars, a high proportion of female and young patrons, lots of sexual activity, a large number of patrons and staff, security staff present, better monitoring and coordination by staff, and people hanging around at closing. Incidents at tables and pool tables tended to occur in bars with the opposite characteristics. Nightly variations in patron intoxication and rowdiness were associated with aggression at tables while variations in crowding and sexual activity were associated with aggression in areas of movement. Incidents outside tended to be more severe. Discussion and Conclusions Each aggression location and their associated environments have somewhat different implications for staff training, premises design, policy and prevention. PMID:22050319
'Hotspots' for aggression in licensed drinking venues.
Graham, Kathryn; Bernards, Sharon; Osgood, D Wayne; Wells, Samantha
2012-06-01
In order to better understand the social context of barroom aggression, the aim was to identify common locations ('hotspots') for aggression in bars and examine the association of hotspots with aggression severity and environmental characteristics. Aggression hotspots were identified using narrative descriptions and data recorded on premises' floor plans for 1057 incidents of aggression collected in the Safer Bars evaluation. Hierarchical Linear Modelling was used to identify bar-level and night-level characteristics associated with each hotspot. The most common location for aggression was the dance floor (20.0% of incidents) or near the dance floor (11.5%), followed by near the serving bar (15.7%), at tables (13.1%), aisles, hallways and other areas of movement (6.2%), entrance (4.5%) and the pool playing area (4.1%). Hotspots were predicted mainly by bar-level characteristics, with dance floor aggression associated with crowded bars, a high proportion of female and young patrons, lots of sexual activity, a large number of patrons and staff, security staff present, better monitoring and coordination by staff, and people hanging around at closing. Incidents at tables and pool tables tended to occur in bars with the opposite characteristics. Nightly variations in patron intoxication and rowdiness were associated with aggression at tables while variations in crowding and sexual activity were associated with aggression in areas of movement. Incidents outside tended to be more severe. Each aggression location and their associated environments have somewhat different implications for staff training, premises design, policy and prevention. © 2011 Australasian Professional Society on Alcohol and other Drugs.
Neurophysiology of the pelvic floor in clinical practice: a systematic literature review
Bianchi, Francesca; Squintani, Giovanna Maddalena; Osio, Maurizio; Morini, Alberto; Bana, Cristina; Ardolino, Gianluca; Barbieri, Sergio; Bertolasi, Laura; Caramelli, Riccardo; Cogiamanian, Filippo; Currà, Antonio; de Scisciolo, Giuseppe; Foresti, Camillo; Frasca, Vittorio; Frasson, Emma; Inghilleri, Maurizio; Maderna, Luca; Motti, Luisa; Onesti, Emanuela; Romano, Marcello Calogero; Del Carro, Ubaldo
2017-01-01
Summary Neurophysiological testing of the pelvic floor is recognized as an essential tool to identify pathophysiological mechanisms of pelvic floor disorders, support clinical diagnosis, and aid in therapeutic decisions. Nevertheless, the diagnostic value of these tests in specific neurological diseases of the pelvic floor is not completely clarified. Seeking to fill this gap, the members of the Neurophysiology of the Pelvic Floor Study Group of the Italian Clinical Neurophysiology Society performed a systematic review of the literature to gather available evidence for and against the utility of neurophysiological tests. Our findings confirm the utility of some tests in specific clinical conditions [e.g. concentric needle electromyography, evaluation of sacral reflexes and of pudendal somatosensory evoked potentials (pSEPs) in cauda equina and conus medullaris lesions, and evaluation of pSEPs and perineal sympathetic skin response in spinal cord lesions], and support their use in clinical practice. Other tests, particularly those not currently supported by high-level evidence, when employed in individual patients, should be evaluated in the overall clinical context, or otherwise used for research purposes.
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
40. INTERIOR VIEW TO THE SOUTHEAST OF ROOM 302, A ...
40. INTERIOR VIEW TO THE SOUTHEAST OF ROOM 302, A SMALL ISOLATED OFFICE ON THE THIRD FLOOR ON THE EAST SIDE OF THE DISASSEMBLY BAY. A METAL SPIRAL STAIRCASE IS IN THE SOUTHEAST CORNER AND HATCHWAYS ARE IN THE CEILING AND FLOOR TOWARD THE EAST SIDE OF THE ROOM. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
LPT. Low power test (TAN640 and 641) floor plan. Cells ...
LPT. Low power test (TAN-640 and -641) floor plan. Cells 101 and 102, control rooms, shielded counting room, generator room, list of room numbers and names. Door details. Ralph M. Parsons 1229-12 ANP/GE-7-640-A-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0640-00-693-107274 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. FLOOR PLAN AND SECTION OF FLASH ...
PROCESS WATER BUILDING, TRA-605. FLOOR PLAN AND SECTION OF FLASH EVAPORATOR ROOM SHOWING ITS LOCATION ABOVE THE SEAL AND SUMP TANKS. PIPING TAKES WATER FROM SEAL TANK UPWARD TO FLASH EVAPORATORS AND THEN BACK DOWN TO SUMP TANK. BLAW-KNOX 3150-5-6, 8/1950. INL INDEX NO. 531-605-00-098-100011, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Wei, John T; Dunn, Rodney; Nygaard, Ingrid; Burgio, Kathryn; Lukacz, Emily S; Markland, Alayne; Wren, Patricia A; Brubaker, Linda; Barber, Matthew D; Jelovsek, J Eric; Spino, Cathie; Meikle, Susie; Janz, Nancy
To establish validity for the Pelvic Floor Disorders Network (PFDN) self-administered Adaptive Behavior Index (ABI) and to assess whether ABI assesses known discordance between severity of pelvic floor symptoms and self-reported bother. In addition to the ABI questionnaire, participants in 1 of 6 Pelvic Floor Disorders Network trials completed condition-specific measures of pretreatment symptom severity (including Pelvic Floor Distress Inventory; PFDI) and health-related quality of life (Pelvic Floor Impact Questionnaire; PFIQ). The final survey was developed from an iterative process using subject and expert endorsement, factor analyses, and response distributions. Domains were created using a development cohort (n = 304 women), reliability and validity were established using a validation cohort (n = 596 women), and test-retest reliability was assessed (n = 111 women). Factor analyses supported an 11-item avoidance domain and a 6-item hygiene domain. Cronbach' alphas were 0.88 and 0.68, respectively. Test-retest reliability was 0.84 for both domains. Construct validity was demonstrated in correlations between the ABI domains and baseline PFDI and PFIQ (r values, 0.43-0.79 with all P values <0.0001). Moreover, the ABI accounted for 8% to 26% of unexplained variance between the symptoms severity measure and the impact on health related quality of life. After treatment, avoidance domain scores improved for urinary and fecal incontinence groups and hygiene scores improved for the fecal incontinence group. The ABI is a reliable and valid measure in women with pelvic floor disorders. Adaptive behaviors account in part for discordance between pelvic floor symptom severity and bother.
Verdon, Megan; Zegarra, Natalia; Achayra, Rutu; Hemsworth, Paul H
2018-06-05
This research studied whether floor feeding group-housed sows their daily allocation over multiple feed drops per day provides more equitable feeding opportunities in later drops. Over four time replicates, 275 sows were mixed into groups of 10 for both their first and second gestations (200 sows/gestation, 126 sows observed in both gestations). The feeding behavior of individual sows was recorded for 10 min following each of four feed drops per day (0730, 0900, 1100, 1500 h) on days 2, 9 and 51 post-mixing. The location of feeding sows (i.e., feeding in areas associated with high, reduced or little/no food availability) was also recorded. Sow aggressive behavior on day 2 was used to classify sows as dominant (D), subdominant (SD), or submissive (SM). Dominant sows spent the most time feeding in areas of high-food availability (gestation 1, p < 0.001; gestation 2, p = 0.023); SD sows fed more frequently than D sows from areas of reduced food availability (gestation 1, p = 0.001; gestation 2, p = 0.025); and SM sows performed more feeding behavior in areas of little/no food availability (gestation 1, p < 0.001; gestation 2, p < 0.001). These relationships did not change over feed drops or days in either gestation ( p > 0.05). Further research on the management and design of floor feeding systems is required, with a particular emphasis on increasing accessibility to sows that avoid the feeding area.
Surficial geology of the sea floor in Long Island Sound offshore of Plum Island, New York
McMullen, K.Y.; Poppe, L.J.; Danforth, W.W.; Blackwood, D.S.; Schaer, J.D.; Ostapenko, A.J.; Glomb, K.A.; Doran, E.F.
2010-01-01
The U.S. Geological Survey (USGS), the Connecticut Department of Environmental Protection, and the National Oceanic and Atmospheric Administration (NOAA) have been working cooperatively to interpret surficial sea-floor geology along the coast of the Northeastern United States. NOAA survey H11445 in eastern Long Island Sound, offshore of Plum Island, New York, covers an area of about 12 square kilometers. Multibeam bathymetry and sidescan-sonar imagery from the survey, as well as sediment and photographic data from 13 stations occupied during a USGS verification cruise are used to delineate sea-floor features and characterize the environment. Bathymetry gradually deepens offshore to over 100 meters in a depression in the northwest part of the study area and reaches 60 meters in Plum Gut, a channel between Plum Island and Orient Point. Sand waves are present on a shoal north of Plum Island and in several smaller areas around the basin. Sand-wave asymmetry indicates that counter-clockwise net sediment transport maintains the shoal. Sand is prevalent where there is low backscatter in the sidescan-sonar imagery. Gravel and boulder areas are submerged lag deposits produced from the Harbor Hill-Orient Point-Fishers Island moraine segment and are found adjacent to the shorelines and just north of Plum Island, where high backscatter is present in the sidescan-sonar imagery.
139. VIEW OF AGENA TRANSFER AREA SHELTER (117A), LSB (BLDG. ...
139. VIEW OF AGENA TRANSFER AREA SHELTER (117A), LSB (BLDG. 770), FROM VEHICLE CHECKOUT AREA (117). STAINLESS STEEL FLOOR SQUARE BY LOCKER WAS LEVEL PEDESTAL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Manning, D P; Jones, C
2001-04-01
Research over a period of about 18 years has shown that a microcellular polyurethane known as AP66033 is the most slip-resistant safety footwear soling material on oily and wet surfaces. In recent years it has been replaced in commercially available footwear by a dual density polyurethane (DDP) which has a dense outer layer and a soft microcellular backing. This research programme has compared the slip resistance of AP66033 with DDP and some rubber solings. In addition, data were obtained on the effects of soling and floor roughness, and floor polish on slip resistance. Some data were also obtained for walking on ice. The coefficient of friction (CoF) of the solings was measured on 19 water wet surfaces in three conditions: (I) when the solings were new, (II) following abrasion to create maximum roughness and (III) after polishing. The CoF was measured on four oily surfaces after each of 11 abrasion or polishing treatments. The profound effects of the roughening of all soles and of floor roughness on the CoF were demonstrated for both wet and oily surfaces. The superior slip resistance of AP66033 was confirmed for oily and wet conditions; however, some rubbers not suitable for safety footwear achieved higher CoF values on wet floors. All of the floor polishes reduced the CoF of all floors when contaminated with water. The mean CoF of DDP solings was lower than the mean for AP66033 on wet and oily surfaces. No safety footwear soling provided adequate grip on dry ice and the CoF was reduced by water on the ice. A rubber used for rock climbing footwear was one of the most slip-resistant solings on wet surfaces in the laboratory but recorded the lowest CoF on ice. It is concluded that the incidence of occupational injuries caused by slipping could be reduced by the following: (A) returning to safety footwear soled with the microcellular polyurethane AP66033; (B) abrading all new and smooth footwear solings with a belt sanding machine coated with P100 grit; (C) avoiding the use of floor polish; (D) informing the general public about the poor slip resistance of ordinary footwear on ice and the lowering of slip resistance in cold weather.
Ahrens, F; Platz, S; Link, C; Mahling, M; Meyer, H H D; Erhard, M H
2011-05-01
The objective was to investigate the effect of changing the flooring in the alleys of a barn from slatted concrete to slatted rubber mats on hoof disorders and animal hygiene in 44 loose-housed Brown Swiss dairy cows. Cows were examined for disorders of the hind hooves (hemorrhages, white line fissures, ulcers, heel horn erosion, and digital dermatitis) and for skin lesions. The dirtiness of the animals and of the floor was recorded. Climatic (temperature, humidity) and ammonia gas conditions were measured. Evaluations were carried out when the cows were housed on a concrete slatted floor and after 4 and 10 mo on soft flooring (slatted rubber mats, 29-mm thick). The anatomical portion of claw (medial, lateral), number of lactations (parity), and days in milk were included as covariates in the statistical model. Changing the flooring from slatted concrete to slatted rubber mats increased the score for white line fissures [1.0 ± 0.3 (concrete) vs. 2.5 ± 0.4 (10 mo rubber mats)] and influenced air humidity (i.e., the difference in the absolute humidity between the inside and outside of the barn increased from 1.5 ± 0.1 to 1.7 ± 0.2g/m(3)), whereas the other hoof disorders, skin lesions (score of 8.7 ± 0.3), the dirtiness of the animals (score of 5.9 ± 0.3), and the floor (score of 2.1 ± 0.1), and ammonia gas concentration (2.6 ± 0.3mg/kg) were not affected (overall scores or measures; mean ± SE). Lateral claws were more affected (except for heel horn erosion) than medial claws (estimated effects between 1.3 ± 0.2 and 3.0 ± 0.6). Parity influenced hoof disorders (except for hemorrhages) and skin lesions (estimated effects between -0.6 ± 0.3 and 0.5 ± 0.2). Days in milk influenced hoof disorders, but had no effect on skin lesions and on the dirtiness of the animal. Irrespective of floor type, the slots (2.6 ± 0.1) were dirtier than the slats (1.6 ± 0.1). In conclusion, covering slatted concrete flooring with slatted rubber mats partially impaired hoof health but did not influence skin lesions or the dirtiness of the cows or the floor. Similar results were found for climatic conditions, as ammonia gas concentration was not affected, but absolute humidity increased in the barn when rubber mats were present. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bell, L.
2002-01-01
The Sasakawa International Center for Space Architecture (SICSA) has a long history of projects that involve design of space structures, including habitats for low-Earth orbit (LEO) and planetary applications. Most of these facilities and component systems are planned to comply with size, geometry and mass restrictions imposed by the Space Shuttle Orbiter's payload and lift/landing abort restrictions. These constraints limit launch elements to approximately 15 ft. diameter, 40 ft. long cylindrical dimensions weighing no more than approximately 25 metric tons. It is clear that future success of commercial space programs such as tourism will hinge upon the availability of bigger and more efficient Earth to LEO launch vehicles which can greatly reduce transportation and operational costs. This will enable development and utilization of larger habitat modules and other infrastructure elements which can be deployed with fewer launches and on-orbit assembly procedures. The sizing of these new heavy lift launchers should be scaled to optimize habitat functionality and efficiency, just as the habitat designs must consider optimization of launch vehicle economy. SICSA's planning studies address these vehicle and habitat optimization priorities as parallel and interdependent considerations. The allowable diameter of habitat modules established by launch vehicle capacity dictates functionally acceptable internal configuration options. Analyses of these options relative to practical dimensions for Earth-to-orbit launch vehicle scaling were conducted for two general schemes. The "bologna slice" configuration stacks the floors within a predominately cylindrical or spherical envelope, producing circular areas. The "banana split" approach divides a cylindrical module longitudinally, creating floors that are generally rectangular in shape. The assessments established minimum sizes for reasonable utility and efficiency. The bologna slice option. This configuration is only acceptable for modules with diameters of approximately 45 ft. or more. Smaller dimensions will severely limit maximum sight lines, creating claustrophobic conditions. Equipment racks and other elements typically located around internal parameters will further reduce open areas, and vertical circulation access ways between floor levels will diminish usable space even more. However this scheme can work very well for larger diameter habitats, particularly for surface applications where a relatively wide-based/low height module is to be landed vertically. The banana split option. A longitudinal floor orientation can serve very satisfactorily for modules with diameters of 15 ft. or more. Unlike the bologna slice's circular floors, the rectangular spaces offer considerable versatility to accommodate diverse equipment and functional arrangements. Modules smaller than 15 ft. in diameter (the International Space Station standard) will be incompatible with efficient equipment rack design and layouts due to tight-radius wall curvatures. Beyond the 15 ft. diameters, it is logical to scale the modules at dimensional increments based upon the number of desired floors, allowing approximately 8-9 ft. of height/level. Current SICSA Mars mission planning advocates development of new launchers with payload accommodations for 45 ft. diameter, 200 metric ton cargo elements. This large booster will offer launch economies along with habitat scaling advantages. Launch system design efficiencies are influenced by the amount of functional drag that results as the vehicle passes through the Earth's atmosphere. These drag losses are subject to a "cubed-squared law". As the launchcraft's external dimensions increase, its surface area increases with the square of the dimension, while the volume increases with the cube. Since drag is a function of surface, not volume, increasing the vehicle size will reduce proportional drag losses. For this reason, the huge Saturn V Moon rocket experienced relatively low drag. Module pressure envelope geometries also influence internal layout versatility and functionality. SICSA examined cylindrical and spherical envelope approaches for habitat module application, exploring special advantages and disadvantages each presented. The 45 ft. diameter sphere constrained functional volumes and layouts around the upper level perimeter. A modified scheme was selected which reshaped and expanded the height of that area. SICSA's final plan proposes 45 ft. diameter modules of modified spherical form.
Flooring in front of the feed bunk affects feeding behavior and use of freestalls by dairy cows.
Tucker, C B; Weary, D M; de Passillé, A M; Campbell, B; Rushen, J
2006-06-01
In 2 experiments we assessed how preferences, time budgets, and feeding behavior of dairy cows change in response to flooring surfaces in front of the feed bunk. In Experiment 1, 12 nonlactating dairy cattle were individually housed with access to 2 standing platforms filled with either concrete or sawdust. In Experiment 2, 24 nonlactating dairy cattle were given access to either concrete or Animat rubber flooring in front of the feed bunk. In Experiment 1, cows preferred the sawdust to the concrete flooring. In both experiments, cows provided with a softer floor in front of the feed bunk spent more time standing near the feed bunk without eating (Experiment 1: 67 vs. 40 min/d on sawdust vs. concrete, respectively, SEM = 5.6 min/d; Experiment 2: 176 vs. 115 min/d on Animat vs. concrete, respectively, SEM = 20.5 min/d) compared with when they were kept on concrete. The increased time spent at the feed bunk was due to a combination of more frequent eating and standing bouts, indicating that cows were more willing to move on nonconcrete flooring. Total time spent eating was significantly greater on the softer floor in Experiment 2, but not in Experiment 1 (Exp. 1: 289 vs. 275 min/d on sawdust and concrete, respectively, SEM = 7.3 min/d; Exp. 2: 330 vs. 289 min/d on Animat and concrete, respectively, SEM = 15.4), although feed intake was increased on the sawdust treatment in Experiment 1. Cows spent significantly more time lying in the feed alley when the flooring was rubber (219 vs. 53 min/d on Animat and concrete, SEM = 53.6 min/d), perhaps because the lying area in Experiment 2 was inadequate. In conclusion, cows prefer to stand on softer flooring in front of the feed bunk, and are more willing to move on and spend more time standing in front of the feed bunk when provided with softer flooring. These results indicate that cows find softer flooring surfaces more comfortable to stand on than concrete, and highlight the importance of evaluating the comfort of the entire facility.
Effects of housing density and cage floor space on C57BL/6J mice
Smith, A.L.; Mabus, S.L.; Stockwell, J.D.; Muir, C.
2004-01-01
The Guide for the Care and Use of Laboratory Animals (the Guide) is widely accepted as the housing standard by most Institutional Animal Care and Use Committees. The recommendations are based on best professional judgment rather than experimental data. Current efforts are directed toward replacing these guidelines with data-driven, species-appropriate standards. Our studies were undertaken to determine the optimum housing density for C57BL/6J mice, the most commonly used inbred mouse strain. Four-week-old mice were housed for 8 weeks at four densities (the recommended ???12 in2 [ca. 77.4 cm 2]/mouse down to 5.6 in2 [ca. 36.1 cm2]/mouse) in three cage types with various amounts of floor space. Housing density did not affect a variety of physiologic parameters but did affect certain micro-environmental parameters, although these remained within accepted ranges. A second study was undertaken housing C57BL/6J mice with as little as 3.2 in2/mouse (ca. 20.6 cm2). The major effect was elevated ammonia concentrations that exceeded limits acceptable in the workplace at increased housing densities; however, the nasal passages and eyeballs of the mice remained microscopically normal. On the basis of these results, we conclude that C57BL/6J mice as large as 29 g may be housed with 5.6 in2 of floor space per mouse. This area is approximately half the floor space recommended in the Guide. The role of the Guide is to ensure that laboratory animals are well treated and housed in a species-appropriate manner. Our data suggest that current policies could be altered in order to provide the optimal habitation conditions matched to this species' social needs. Copyright 2004 by the American Association for Laboratory Animal Science.
Animal Welfare and Food Safety Aspects of Confining Broiler Chickens to Cages
Shields, Sara; Greger, Michael
2013-01-01
Simple Summary In commercial chicken meat production, broiler chickens are usually kept on the floor in ware-house like buildings, but the use of cages is becoming more common. Confining chickens to cages is a welfare problem, as has been thoroughly demonstrated for laying hens used for egg production. Caged broiler chickens may suffer from poor bone strength due to lack of exercise, feather loss, and restriction of natural behavior. There are also potential food safety concerns associated with the use of cages. While cages may provide an economic advantage in some geographical regions of the world, the severe, inherent disadvantages should also be considered before cages are more widely adopted in the global broiler chicken industry. Abstract In most areas of the world, broiler chickens are raised in floor systems, but cage confinement is becoming more common. The welfare of broiler chickens in cages is affected by movement restriction, poor bone strength due to lack of exercise, and prevention of key behavioral patterns such as dustbathing and ground scratching. Cages for broiler chickens also have a long history of causing skin and leg conditions that could further compromise welfare, but a lack of controlled studies makes it difficult to draw conclusions about newer cage designs. Cage environments are usually stocked at a higher density than open floor systems, and the limited studies available suggest that caging may lead to increased levels of fear and stress in the birds. Further, birds reared on the floor appear less likely to harbor and shed Salmonella, as litter may serve as a seeding agent for competitive exclusion by other microorganisms. Cages for laying hens used in egg production have met with substantial opposition due to welfare concerns and caging broiler chickens will likely be subject to the same kinds of social disapproval. PMID:26487409
Cochran, Susan A.; Gibbs, Ann E.; White, Darla J.
2014-01-01
Nearshore areas off of west-central Maui, Hawai‘i, once dominated by abundant coral coverage, now are characterized by an increased abundance of turf algae and macroalgae. In an effort to improve the health and resilience of the coral reef system, the Kahekili Herbivore Fisheries Management Area was established by the State of Hawai‘i, and the U.S. Coral Reef Task Force selected the Kā‘anapali region as a priority study area. To support these efforts, the U.S. Geological survey mapped nearly 5 km2 of sea floor from the shoreline to water depths of about 30 m. Unconsolidated sediment (predominantly sand) constitutes 65 percent of the sea floor in the mapped area. Reef and other hardbottom potentially available for coral recruitments constitutes 35 percent of the mapped area. Of this potentially available hardbottom, only 51 percent is covered with a minimum of 10 percent coral, and most is found between 5 and 10 m water depth.
Pelvic Floor Dynamics During High-Impact Athletic Activities: A Computational Modeling Study
Dias, Nicholas; Peng, Yun; Khavari, Rose; Nakib, Nissrine A.; Sweet, Robert M.; Timm, Gerald W.; Erdman, Arthur G.; Boone, Timothy B.
2017-01-01
Background Stress urinary incontinence is a significant problem in young female athletes, but the pathophysiology remains unclear because of the limited knowledge of the pelvic floor support function and limited capability of currently available assessment tools. The aim of our study is to develop an advanced computer modeling tool to better understand the dynamics of the internal pelvic floor during highly transient athletic activities. Methods Apelvic model was developed based on high-resolution MRI scans of a healthy nulliparous young female. A jump-landing process was simulated using realistic boundary conditions captured from jumping experiments. Hypothesized alterations of the function of pelvic floor muscles were simulated by weakening or strengthening the levator ani muscle stiffness at different levels. Intra-abdominal pressures and corresponding deformations of pelvic floor structures were monitored at different levels of weakness or enhancement. Findings Results show that pelvic floor deformations generated during a jump-landing process differed greatly from those seen in a Valsalva maneuver which is commonly used for diagnosis in clinic. The urethral mobility was only slightly influenced by the alterations of the levator ani muscle stiffness. Implications for risk factors and treatment strategies were also discussed. Interpretation Results suggest that clinical diagnosis should make allowances for observed differences in pelvic floor deformations between a Valsalva maneuver and a jump-landing process to ensure accuracy. Urethral hypermobility may be a less contributing factor than the intrinsic sphincteric closure system to the incontinence of young female athletes. PMID:27886590
The influence of "preparedness" on autoshaping, schedule performance, and choice.
Burns, J D; Malone, J C
1992-11-01
Two groups of experimentally naive pigeons were exposed to an autoshaping procedure in which the response key was mounted on the wall (the conventional location) or on the floor of the chamber. In two experiments, subjects readily responded to the wall key, but floor-key subjects required shaping. A subsequent experiment compared performance of wall- and floor-key groups on an ascending series of fixed-ratio schedule values, resistance to extinction, differential reinforcement of other behavior, and reversal of key assignment. Each experiment was followed by several sessions of fixed-ratio training; the performance of the wall- and floor-key groups was almost identical throughout. In the final experiment, a fixed-ratio requirement could be completed on either or both keys. Birds initially chose the key on which they had responded during the preceding (reversal of key assignment) experiment. However, within a few sessions both groups showed almost exclusive preference for the floor key. Preference for a key located on the floor may follow from the fact that pigeons are ground feeders and may thus be more "prepared" to peck the floor than to peck a wall. However, autoshaping, under the conditions prevailing here, occurred much more readily to the wall key, suggesting that pecking a vertical surface is more highly prepared. Difficulties in determining relative preparedness seem moot, however, given the lack of between-group differences in the intervening experiments. It is thus unlikely that schedule performances critically depend upon the specific operant response involved.
NASA Astrophysics Data System (ADS)
Stein, M.; Palchan, D.; Goldstein, S. L.; Almogi-Labin, A.; Tirosh, O.; Erel, Y.
2017-12-01
The last interglacial peak, Marine Isotope Stage 5e (MIS 5e), was associated with stronger northern hemisphere insolation, higher global sea levels and higher average global temperatures compared to the Holocene, and is considered as an analogue for a future warming world. In this perspective the present-day areas of the Sahara - Arabia deserts (the "desert belt") are of special interest since their margins are densely inhabited and global climate models predict enhanced aridity in these regions due to future warming. The Red Sea situated at the midst of the desert belt and the Dead Sea at the northern fringe of the desert belt comprise sensitive monitors for past hydroclimate changes in the Red Sea-Levant regions as global climate shifted from glacial to interglacial conditions. Here, we reconstruct the synoptic conditions that controlled desert dust transport to the Red Sea and the Dead Sea during MIS5e. The reconstruction is based on Nd-Sr isotopes and chemical composition of carbonate-free detritus recovered from sediment cores drilled at the deep floors of these water-bodies combined with data of contemporaneous dust storms transporting dust to the lake and sea floors. During Termination 2 ( 134-130 ka) the Sahara, Nile River desiccated and the Dead Sea watershed were under extreme dry conditions manifested by lake level drop, deposition of salt and enhanced transport of Sahara dusts to the entire studied transect. At the peak of the interglacial MIS 5e ( 130-120 ka), enhanced flooding activity mobilized local fine detritus from the surroundings of the Red Sea and the Dead Sea watershed into the water-bodies. This interval coincided with the Sapropel event S5 in the Mediterranean that responded to enhanced monsoon rains at the heads of the Blue Nile River. At the end of MIS 5e ( 120-116 ka) the effect of the regional floods faded and the Dead Sea and Red Sea areas re-entered sever arid conditions with salt deposition at the Dead Sea. Overall, the desert margins were under turbulent climate regime during the last interglacial period, fluctuating between contraction and expansions manifested with extreme enhanced flooding and extreme arid spells.
Harmer, S G; Ethunandan, M; Zaki, G A; Brennan, P A
2007-03-01
A 52-year-old man was being attended to in a hospital for a fracture of the right zygoma and orbital floor, after being struck on the right upper face. After blowing his nose, he immediately lost vision in the right eye, and an urgent CT scan showed extensive retrobulbar air. Vision was regained within an hour. The management of this rare condition is discussed.
Wiegersma, Marian; Panman, Chantal M C R; Kollen, Boudewijn J; Berger, Marjolein Y; Lisman-Van Leeuwen, Yvonne; Dekker, Janny H
2014-12-22
To compare the effects of pelvic floor muscle training and watchful waiting on pelvic floor symptoms in a primary care population of women aged 55 years and over with symptomatic mild pelvic organ prolapse. Randomised controlled trial. Dutch primary care. Women aged 55 years or over with symptomatic mild prolapse (leading edge above the hymen) were identified by screening. Exclusion criteria were current prolapse treatment or treatment in the previous year, malignancy of pelvic organs, current treatment for another gynaecological disorder, severe/terminal illness, impaired mobility, cognitive impairment, and insufficient command of the Dutch language. Pelvic floor muscle training versus watchful waiting. The primary outcome was change in bladder, bowel, and pelvic floor symptoms measured with the Pelvic Floor Distress Inventory-20 (PFDI-20), three months after the start of treatment. Secondary outcomes were changes in condition specific and general quality of life, sexual function, degree of prolapse, pelvic floor muscle function, and patients' perceived change in symptoms. Of the 287 women who were randomised to pelvic floor muscle training (n=145) or watchful waiting (n=142), 250 (87%) completed follow-up. Participants in the intervention group improved by (on average) 9.1 (95% confidence interval 2.8 to 15.4) points more on the PFDI-20 than did participants in the watchful waiting group (P=0.005). Of women in the pelvic floor muscle training group, 57% (82/145) reported an improvement in overall symptoms from the start of the study compared with 13% (18/142) in the watchful waiting group (P<0.001). Other secondary outcomes showed no significant difference between the groups. Although pelvic floor muscle training led to a significantly greater improvement in PFDI-20 score, the difference between the groups was below the presumed level of clinical relevance (15 points). Nevertheless, 57% of the participants in the intervention group reported an improvement of overall symptoms. More studies are needed to identify factors related to success of pelvic floor muscle training and to investigate long term effects.Trial registration Dutch Trial Register (www.trialregister.nl) identifier: NTR2047. © Wiegersma et al 2014.
LOFT. Reactor support apparatus inside containment building (TAN650). Camera is ...
LOFT. Reactor support apparatus inside containment building (TAN-650). Camera is on crane rail level and facing northerly. View shows top two banks of round conduit openings on wall for electrical and other connections to control room. Ladders and platforms provide access to reactor instrumentation. Note hatch in floor and drain at edge of floor near wall. Date: 1974. INEEL negative no. 74-219 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
STS-55 crewmembers repair waste water tank on OV-102's middeck
NASA Technical Reports Server (NTRS)
1993-01-01
Three STS-55 crewmembers participate in an inflight maintenance (IFM) exercise to counter problems experienced with a waste water tank below Columbia's, Orbiter Vehicle (OV) 102's, middeck. Mission Specialist 3 (MS3) Bernard A. Harris, Jr, inside the airlock, holds middeck floor access panel MD54G and looks below at Pilot Terence T. Henricks who is in the bilge area. Commander Steven R. Nagel is lying on middeck floor at the left.
A&M. Hot cell addition (TAN633). Floor plan, elevations. Arrangement of ...
A&M. Hot cell addition (TAN-633). Floor plan, elevations. Arrangement of monorail along corridor, four hot cells, plug access openings, viewing windows, photo darkroom. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-1. Date: December 1956 as redrawn in August 1998. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0633-00-693-107315 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
18. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, MIDDLE ...
18. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, MIDDLE OF MALE MEDIUM SECURITY SLEEPING AREA LOOKING UP AT THE CLERESTORY. THE WOOD TRUSS SYSTEM IS SHOWN IN UPPER RIGHT CORNER OF PHOTO, RETREATING INTO THE BACKGROUND OF THE PHOTO. THE WOOD STRUTS SHOWN IN THE UPPER LEFT OF PHOTO, TRANSVERSES ACROSS TOWARDS THE RIGHT OF PHOTO. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI
LOFT. Containment and service building (TAN650). Section through north/south axis. ...
LOFT. Containment and service building (TAN-650). Section through north/south axis. Shows basement and four additional levels of pre-amp tower, shielded roadway, chambers below reactor floor, railroad door, sumps, shielding. Section C shows basement sumps and chambers below reactor floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-5. Date: October 1964. INEEL index code no. 036-650-00-486-122217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
129. Photographic copy of drawing (24 June 1963, original drawing ...
129. Photographic copy of drawing (24 June 1963, original drawing in Archives, Public Affairs Departmentm, Sears Merchandise Group, Hoffman Estates, Illinois). Swain and Meyers, Inc. 1/4 inch to one foot. Partial floor plan illustrating the layout of the large package handling area. Tables and equipment not present at the time of the survey are shown. SECOND FLOOR, SECTON B - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL
ETR, TRA642. ON GROUND FLOOR. THE 60TON ETR REACTOR VESSEL ...
ETR, TRA-642. ON GROUND FLOOR. THE 60-TON ETR REACTOR VESSEL IS DROPPED INTO PLACE OVER PIT. KAISER USED TWO MULTI-BLOCK DRUM PULLEYS WITH A COMBINED CAPACITY OF 100 TONS AND A 100-TON DRUM HOIST. THE VESSEL WAS 35 1/2 FEET LONG. INL NEGATIVE NO. 56-4149. R.G. Larsen, Photographer, 12/18/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A Neolithic case of fibrous dysplasia from Çatalhöyük (Turkey).
Milella, Marco; Knüsel, Christopher J; Haddow, Scott D
2016-12-01
The vast majority of primary burials at Neolithic Çatalhöyük (Central Anatolia, Turkey, 7100-6000cal BC) are recovered from beneath house floors, with burials in external spaces extremely rare. Excavations at Çatalhöyük in 1998 brought to light a young adult male buried in a midden (a burial location observed so far for only 4 out of 440 individuals), showing a suite of pathological features affecting the entire skeleton. The observed pathological changes include perimortem and antemortem fractures, proliferative and resorptive areas, thinning of the bone cortex, and localized areas of disorganized spongy bone invaded by fibrous tissue. We propose a differential diagnosis by considering a set of conditions: Paget's disease, osteomyelitis, hyperparathyrhoidism, Ollier's disease, fibrosarcoma, and fibrous dysplasia. The severity and distribution of the observed skeletal changes are consistent with a diagnosis of polyostotic fibrous dysplasia, a possibly debilitating and disfiguring condition. This, together with an unusual depositional context, may suggest a socially-mediated reaction to this individual's infirmity. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wattrus, N. J.; Binder, T.
2012-12-01
Until the 1950s, lake trout supported a valuable commercial fishery in the Great Lakes. The introduction of sea lamprey into the Great Lakes and overfishing resulted in the loss of most populations. Despite consistent stocking efforts since the 1960s, restoration of these populations has been slow. The reasons are numerous, but may be related to differences in the spawning behavior between hatchery and wild trout. A four-year study initiated in 2010, utilizes acoustic telemetry to characterize and compare the spawning behaviors of hatchery and wild lake trout in the Drummond Island Refuge in northern Lake Huron. In this project, the movement of tagged fish are monitored by an array of over 125 lake floor hydrophones during the fall spawning period. Fish behavior is overlaid over detailed bathymetric and substrate data and compared with environmental variables (e.g. water temperature, wind speed and direction, and wave height and direction) to develop a conceptual behavioral model. Sites suspected of being spawning sites based upon telemetry data are verified through the use of divers and trapping eggs and fry. Prior to this study, the factors that influenced how the spawning fish utilize the lake floor shoals have been poorly understood. Among the factors thought to impact spawning success were: bathymetry and substrate composition. Diver and telemetry data suggest that the fish(both hatchery raised and wild) are particularly attracted to rocky substrates and that fragment size is important. High resolution multibeam bathymetric surveys conducted in 2010 and 2011 have been used to characterize the shape and composition of the lake floor in the study area. Classification of the substrate is a labor intensive process requiring divers, drop cameras and sediment sampling. To improve this, the traditional approach has been to use supervised and unsupervised classification techniques that are based upon measured acoustic backscatter from an echosounder or sidescan sonar. Bottom classification based upon backscatter measurements from the collected multibeam sonar data using Quester Tangent's Multiview software does not appear to readily resolve the various classes of rocky substrate, for example it appears to have difficulty differentiating between areas dominated by boulder sized rocks from areas covered predominantly by cobble sized fragments. The extremely shallow nature of the reef areas utilized by the spawning fish (z_av < 10 m) ensures that the bathymetric data has a very high spatial resolution (dx ~ 0.1m). Visual inspection of the bathymetry of the reefs clearly show variations in the texture and morphology of the lake floor that correlate with divers' observations of aggregations of fish in spawning condition. We describe the results of a study to investigate the application of terrain analysis for subdividing the reefs into regions based upon their texture and morphology. A variety of descriptors are evaluated as is the influence of scale on the analyses.
Li, Juanjuan; Lee, Kyungmo; Chen, Haohua; Ou, Guomin
2013-11-01
Because of the low bone quality in the posterior maxilla, edentulism in this area often results in a resorbed osseous structure and a pneumatized maxillary sinus, which makes dental implant surgery in the posterior maxilla a challenge. Two main surgical approaches are available for the sinus lift procedure: lateral and crestal. Improvement of the maxillary sinus floor elevation technique and increase in predictability are desirable. This article describes an innovative approach to maxillary sinus floor elevation with piezoelectric surgery and hydraulic pressure for xenograft and simultaneous implant placement in situations with insufficient residual alveolar bone. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Experimental Investigation of Properties of Foam Concrete for Industrial Floors in Testing Field
NASA Astrophysics Data System (ADS)
Vlcek, Jozef; Drusa, Marian; Scherfel, Walter; Sedlar, Bronislav
2017-12-01
Foam concrete (FC), as a mixture of cement, water, additives and technical foam, is well known for more than 30 years. It is building material with good mechanical properties, low thermal conductivity, simple and even high technological treatment. Foam concrete contains closed void pores, what allows achieving low bulk density and spare of raw materials. Thanks to its properties, it is usable as a replacement of conventional subbase layers of the industrial floors, the transport areas or as a part of the foundation structures of the buildings. Paper presents the preparation of the testing field (physical model) which was created for experimental investigation of the foam concrete subbase layer of the industrial floor in a real scale.
Carpeting/Flooring: Revitalizing Carpets.
ERIC Educational Resources Information Center
Woolford, Alison; Hill, Michael
2003-01-01
With properly specified fiber and a comprehensive maintenance program, school carpets can retain their appearance longer. Discusses carpet characteristics; proper carpet installation; effective preventive-maintenance programs (keep outside areas clean, use soil barriers, protect desk areas, maintain HVAC systems, and specify eating, drinking, and…
Code of Federal Regulations, 2014 CFR
2014-07-01
..., floors, roofs, roadways and sidewalks in the industrial area, utility poles, unmanned machinery, concrete... areas above 6 feet in height, roofs, asphalt roadways, concrete roadways, wooden utility poles, unmanned..., metals, glass, aluminum siding, and enameled or laminated surfaces. Low-concentration PCBs means PCBs...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., floors, roofs, roadways and sidewalks in the industrial area, utility poles, unmanned machinery, concrete... areas above 6 feet in height, roofs, asphalt roadways, concrete roadways, wooden utility poles, unmanned..., metals, glass, aluminum siding, and enameled or laminated surfaces. Low-concentration PCBs means PCBs...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., floors, roofs, roadways and sidewalks in the industrial area, utility poles, unmanned machinery, concrete... areas above 6 feet in height, roofs, asphalt roadways, concrete roadways, wooden utility poles, unmanned..., metals, glass, aluminum siding, and enameled or laminated surfaces. Low-concentration PCBs means PCBs...
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-01-01
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at −700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m. PMID:28475168
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control.
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-05-05
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at -700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m.
Sandwich Core Heat-Pipe Radiator for Power and Propulsion Systems
NASA Technical Reports Server (NTRS)
Gibson, Marc; Sanzi, James; Locci, Ivan
2013-01-01
Next-generation heat-pipe radiator technologies are being developed at the NASA Glenn Research Center to provide advancements in heat-rejection systems for space power and propulsion systems. All spacecraft power and propulsion systems require their waste heat to be rejected to space in order to function at their desired design conditions. The thermal efficiency of these heat-rejection systems, balanced with structural requirements, directly affect the total mass of the system. Terrestrially, this technology could be used for thermal control of structural systems. One potential use is radiant heating systems for residential and commercial applications. The thin cross section and efficient heat transportability could easily be applied to flooring and wall structures that could evenly heat large surface areas. Using this heat-pipe technology, the evaporator of the radiators could be heated using any household heat source (electric, gas, etc.), which would vaporize the internal working fluid and carry the heat to the condenser sections (walls and/or floors). The temperature could be easily controlled, providing a comfortable and affordable living environment. Investigating the appropriate materials and working fluids is needed to determine this application's potential success and usage.
Barbour, M M; Hunt, J E; Walcroft, A S; Rogers, G N D; McSeveny, T M; Whitehead, D
2005-02-01
Here we develop and test a method to scale sap velocity measurements from individual trees to canopy transpiration (E(c)) in a low-productivity, old-growth rainforest dominated by the conifer Dacrydium cupressinum. Further, E(c) as a component of the ecosystem water balance is quantified in relation to forest floor evaporation rates and measurements of ecosystem evaporation using eddy covariance (E(eco)) in conditions when the canopy was dry and partly wet. Thermal dissipation probes were used to measure sap velocity of individual trees, and scaled to transpiration at the canopy level by dividing trees into classes based on sapwood density and canopy position (sheltered or exposed). When compared with ecosystem eddy covariance measurements, E(c) accounted for 51% of E(eco) on dry days, and 22% of E(eco) on wet days. Low transpiration rates, and significant contributions to E(eco) from wet canopy evaporation and understorey transpiration (35%) and forest floor evaporation (25%), were attributable to the unique characteristics of the forest: in particular, high rainfall, low leaf area index, low stomatal conductance and low productivity associated with severe nutrient limitation.
Factors influencing restaurant worker perception of floor slipperiness.
Courtney, Theodore K; Huang, Yueng-Hsiang; Verma, Santosh K; Chang, Wen-Ruey; Li, Kai Way; Filiaggi, Alfred J
2006-11-01
Falls are responsible for a substantial injury burden in the global workplace. Restaurant environments are particularly challenged by slips, trips, and falls. This study explored those factors that could influence workers' self-reports of slipperiness in U.S. fast-food restaurants. One hundred and twenty-six workers employed in 10 fast-food restaurants in the northeastern United States participated in the study representing a study-wide response rate of 87.5%. Participants' ratings of floor slipperiness and occupational slip history within the past 4 weeks were collected through written questionnaire. Additional factors collected by questionnaire included age, gender, shift length, and shoe type. Shoe condition (wear) and shoe contamination were visually assessed by the investigators. Floor friction was also measured. Lower restaurant mean coefficient of friction and the presence of contamination on workers' shoe soles were environmental factors significantly associated with workers reporting more slippery conditions. A recent workplace history of slipping with or without a subsequent fall was also significantly associated with workers reporting more slippery conditions. Workers over the age of 45 reported conditions to be significantly less slippery than younger workers. The results suggest that worker ratings of slipperiness are influenced not only by the actual level of friction but also by the other individual and environmental factors noted above. Recommendations for future studies would include a longitudinal design to better capture the temporal sequence between these variables. More field research is needed to better understand the association between workplace conditions, worker perception of slipperiness, and slipping at work.
Effects of two trimming methods of dairy cattle on concrete or rubber-covered slatted floors.
Ouweltjes, W; Holzhauer, M; van der Tol, P P J; van der Werf, J
2009-03-01
This study monitored claw health, claw conformation, locomotion, activity, and step traits of cows from a single dairy herd that were trimmed according to the standard Dutch method or with an alternative "concave" trimming method. Half of the cows were kept in a stall section with concrete slatted floors in the alleys. The other cows were kept in a pen within the same housing with an identical concrete slatted floor in the alleys, but with a rubber top layer. All experimental cows were kept in the same environment for at least 3 mo before and after trimming. It was hypothesized that trimming for more-concave soles (i.e., with 3 to 5 mm of sole dug out under the claw bone) was preferred to the standard Dutch trimming with flat sole surfaces for cows kept in stalls with soft alley floors. None of the claw health or locomotion traits differed for the trimming methods. No interactions were found between flooring and trimming method. Floor effects were significant for several traits. Cows on the rubber-topped floors had significantly fewer sole hemorrhages (prevalence of 22 vs. 48% in mo 3) and larger claws (claw length 76.1 +/- 5.0 vs. 72.5 +/- 4.9 mm; heel height 49.3 +/- 6.3 vs. 46.0 +/- 6.4 mm; claw diagonal 129 +/- 6.4 vs. 125 +/- 6.9 mm), spent more time standing in the alleys (55.4 +/- 2.8 vs. 49.6 +/- 2.8%), and had higher activity (61.0 +/- 3.7 vs. 53.0 +/- 3.7 steps/h). This suggests greater claw comfort on rubber flooring compared with concrete flooring. Kinetic patterns during claw-floor contact while walking were similar for all treatments. During the double-support (stance) phase, claw-floor contact area increased to a maximum in the first 30% of double-support phase time, remained more or less stable until 80% of double-support phase time, and sharply decreased as the animal pushed off as shown by the change in center of pressure. A gradual change of center of pressure in the medial direction during double-support phase time was shown. The research hypothesis was rejected, but soft alley floors had subtle beneficial effects.
Ley-Chavez, Adriana; Hmar-Lagroun, Tatiana; Douglas-Ntagha, Pamela; Cumbo, Charlotte L
2016-01-01
Inefficient facility layouts have been found to be a challenge in health care, with excessive walking adding to the demands of staff and creating delays, which can impact the quality of care. Minimizing unnecessary transportation during care delivery improves efficiency, reduces delays, and frees up resources for use on value-added activities. This article presents a methodology and application of facility design to improve responsiveness and efficiency at a large hospital. The approach described provides the opportunity to improve existing layouts in facilities in which the floor plan is already defined, but there is some flexibility to relocate key areas. The existing physical constraints and work flows are studied and taken into consideration, and the volume of traffic flow throughout the facility guides the decision of where to relocate areas for maximum efficiency. Details on the steps followed and general recommendations to perform the necessary process and data analyses are provided. We achieved a 34.8% reduction in distance walked (4740 miles saved per year) and a 30% reduction in floors traveled in elevators (344 931 floors, which translate to 842 hours spent using elevators) by relocating 4 areas in which frequently used resources are housed.
Using Six Sigma methodology to reduce patient transfer times from floor to critical-care beds.
Silich, Stephan J; Wetz, Robert V; Riebling, Nancy; Coleman, Christine; Khoueiry, Georges; Abi Rafeh, Nidal; Bagon, Emma; Szerszen, Anita
2012-01-01
In response to concerns regarding delays in transferring critically ill patients to intensive care units (ICU), a quality improvement project, using the Six Sigma process, was undertaken to correct issues leading to transfer delay. To test the efficacy of a Six Sigma intervention to reduce transfer time and establish a patient transfer process that would effectively enhance communication between hospital caregivers and improve the continuum of care for patients. The project was conducted at a 714-bed tertiary care hospital in Staten Island, New York. A Six Sigma multidisciplinary team was assembled to assess areas that needed improvement, manage the intervention, and analyze the results. The Six Sigma process identified eight key steps in the transfer of patients from general medical floors to critical care areas. Preintervention data and a root-cause analysis helped to establish the goal transfer-time limits of 3 h for any individual transfer and 90 min for the average of all transfers. The Six Sigma approach is a problem-solving methodology that resulted in almost a 60% reduction in patient transfer time from a general medical floor to a critical care area. The Six Sigma process is a feasible method for implementing healthcare related quality of care projects, especially those that are complex. © 2011 National Association for Healthcare Quality.