Transitioning NWChem to the Next Generation of Manycore Machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bylaska, Eric J.; Apra, E; Kowalski, Karol
The NorthWest chemistry (NWChem) modeling software is a popular molecular chemistry simulation software that was designed from the start to work on massively parallel processing supercomputers [1-3]. It contains an umbrella of modules that today includes self-consistent eld (SCF), second order Møller-Plesset perturbation theory (MP2), coupled cluster (CC), multiconguration self-consistent eld (MCSCF), selected conguration interaction (CI), tensor contraction engine (TCE) many body methods, density functional theory (DFT), time-dependent density functional theory (TDDFT), real-time time-dependent density functional theory, pseudopotential plane-wave density functional theory (PSPW), band structure (BAND), ab initio molecular dynamics (AIMD), Car-Parrinello molecular dynamics (MD), classical MD, hybrid quantum mechanicsmore » molecular mechanics (QM/MM), hybrid ab initio molecular dynamics molecular mechanics (AIMD/MM), gauge independent atomic orbital nuclear magnetic resonance (GIAO NMR), conductor like screening solvation model (COSMO), conductor-like screening solvation model based on density (COSMO-SMD), and reference interaction site model (RISM) solvation models, free energy simulations, reaction path optimization, parallel in time, among other capabilities [4]. Moreover, new capabilities continue to be added with each new release.« less
Habib, Ullah; Cecilia, D Wilfred; Maizatul, S Shaharun
2017-06-08
Ionic liquids (ILs) based ultrasonic-assisted extract has been applied for the extraction of essential oil from Persicaria minor leaves. The effects of temperature, sonication time, and particle size of the plant material on the yield of essential oil were investigated. Among the different ILs employed, 1-ethyl-3-methylimidazolium acetate was the most effective, providing a 9.55% yield of the essential oil under optimum conditions (70 ℃, 25 min, IL:hexane ratio of 7:10 (v/v), particle size 60-80 mesh). The performance of 1-ethyl-3-methylimidazolium acetate in the extraction was attributed to its low viscosity and ability to disintegrate the structural matrix of the plant material. The ability of 1-ethyl-3-methylimidazolium acetate was also confirmed using the conductor like-screening model for realistic solvents. This research proves that ILs can be used to extract essential oils from lignocellulosic biomass.
NASA Astrophysics Data System (ADS)
Gatto, Paolo; Lipparini, Filippo; Stamm, Benjamin
2017-12-01
The domain-decomposition (dd) paradigm, originally introduced for the conductor-like screening model, has been recently extended to the dielectric Polarizable Continuum Model (PCM), resulting in the ddPCM method. We present here a complete derivation of the analytical derivatives of the ddPCM energy with respect to the positions of the solute's atoms and discuss their efficient implementation. As it is the case for the energy, we observe a quadratic scaling, which is discussed and demonstrated with numerical tests.
Paduszyński, Kamil
2018-04-12
A conductor-like screening model for real solvents (COSMO-RS) is nowadays one of the most popular and commonly applied tools for the estimation of thermodynamic properties of complex fluids. The goal of this work is to provide a comprehensive review and analysis of the performance of this approach in calculating liquid-liquid equilibrium (LLE) phase diagrams in ternary systems composed of ionic liquid and two molecular compounds belonging to diverse families of chemicals (alkanes, aromatics, S/N-compounds, alcohols, ketones, ethers, carboxylic acid, esters, and water). The predictions are presented for extensive experimental database, including 930 LLE data sets and more than 9000 data points (LLE tie lines) reported for 779 unique ternary mixtures. An impact of the type of molecular binary subsystem on the accuracy of predictions is demonstrated and discussed on the basis of representative examples. The model's capability of capturing qualitative trends in the LLE distribution ratio and selectivity is also checked for a number of structural effects. Comparative analysis of two levels of quantum chemical theory (BP-TZVP-COSMO vs BP-TZVPD-FINE) for the input molecular data for COSMO-RS is presented. Finally, some general recommendations for the applicability of the model are indicated based on the analysis of the global performance as well as on the results obtained for systems relevant from the point of view of important separation problems.
Advancement of Analysis Method for Electromagnetic Screening Effect of Mountain Tunnel
NASA Astrophysics Data System (ADS)
Okutani, Tamio; Nakamura, Nobuyuki; Terada, Natsuki; Fukuda, Mitsuyoshi; Tate, Yutaka; Inada, Satoshi; Itoh, Hidenori; Wakao, Shinji
In this paper we report advancement of an analysis method for electromagnetic screening effect of mountain tunnel with a multiple conductor circuit model. On A.C. electrified railways it is a great issue to manage the influence of electromagnetic induction caused by feeding circuits. Tunnels are said to have a screening effect to reduce the electromagnetic induction because a large amount of steel is used in the tunnels. But recently the screening effect is less expected because New Austrian Tunneling Method (NATM), in which the amount of steel used is less than in conventional methods, is adopted as the standard tunneling method for constructing mountain tunnels. So we measured and analyzed the actual screening effect of mountain tunnels constructed with NATM. In the process of the analysis we have advanced a method to analyze the screening effect more precisely. In this method we can adequately model tunnel structure as a part of multiple conductor circuit.
Kuechler, Erich R; Giese, Timothy J; York, Darrin M
2016-04-28
To better represent the solvation effects observed along reaction pathways, and of ionic species in general, a charge-dependent variable-radii smooth conductor-like screening model (VR-SCOSMO) is developed. This model is implemented and parameterized with a third order density-functional tight binding quantum model, DFTB3/3OB-OPhyd, a quantum method which was developed for organic and biological compounds, utilizing a specific parameterization for phosphate hydrolysis reactions. Unlike most other applications with the DFTB3/3OB model, an auxiliary set of atomic multipoles is constructed from the underlying DFTB3 density matrix which is used to interact the solute with the solvent response surface. The resulting method is variational, produces smooth energies, and has analytic gradients. As a baseline, a conventional SCOSMO model with fixed radii is also parameterized. The SCOSMO and VR-SCOSMO models shown have comparable accuracy in reproducing neutral-molecule absolute solvation free energies; however, the VR-SCOSMO model is shown to reduce the mean unsigned errors (MUEs) of ionic compounds by half (about 2-3 kcal/mol). The VR-SCOSMO model presents similar accuracy as a charge-dependent Poisson-Boltzmann model introduced by Hou et al. [J. Chem. Theory Comput. 6, 2303 (2010)]. VR-SCOSMO is then used to examine the hydrolysis of trimethylphosphate and seven other phosphoryl transesterification reactions with different leaving groups. Two-dimensional energy landscapes are constructed for these reactions and calculated barriers are compared to those obtained from ab initio polarizable continuum calculations and experiment. Results of the VR-SCOSMO model are in good agreement in both cases, capturing the rate-limiting reaction barrier and the nature of the transition state.
Fabrication and modeling of stretchable conductors for traumatic brain injury research
NASA Astrophysics Data System (ADS)
Cao, Wenzhe
Stretchable electronics are an emergent class of electronics that can retain their electric functionality under large mechanical deformation, such as stretching, bending and compression. Like traditional electric circuits, stretchable electronics rely on electrical conductors, but in this specific instance the conductors must also be stretchable. This thesis research had three goals: (1) fabricate elastically stretchable conductors that retain their electrical conductance when stretched by tens of percent of strain; (2) understand the underlying stretching mechanism of gold conductors on polydimethylsiloxane (PDMS) substrates; (3) produce a special device---a stretchable microelectrode array, which contains a matrix of stretchable conductors that enables a new approach to studying traumatic brain injury. We first developed and optimized the micro-fabrication process to make elastically stretchable thin gold film conductors on PDMS substrates. The conductors can retain electrical conduction while being stretched reversibly to 140% uniaxially and 16% radially. We further developed a fabrication process to encapsulate the conductors with either a commercially available photopatternable silicone (PPS) or with PDMS. 100 microm by 100 microm vias were patterned in the encapsulation layer to expose electrical contacts. PPS encapsulated conductors can be stretched uniaxially to 80%, and the PDMS encapsulated conductor can be stretched to ˜15%, without losing electrical conduction. We also introduced acrylate-based shape memory polymers (SMPs) as a new type of substrate for stretchable conductors. Their stiffness can be tuned by varying the monomer composition or by changing the ambient temperature. Thin gold film conductors deposited on pre-strained SMPs remain conductive when first stretched and then relaxed to their pre-strain value. Moreover, an SMP can also serve as a stretchable carrier to make pre-strained conductors on an overlying PDMS membrane. The resistance of gold conductors made on pre-strained PDMS changes less during stretching than that made on non-pre-strained PDMS substrate. We built a model of the electrical resistance in function of strain. The model is based on the topography of the thin gold film on PDMS. This model is a first attempt at predicting electrical resistance of stretchable thin gold film conductors. Lastly, we fabricated stretchable microelectrode arrays (SMEAs). They were utilized at Columbia University to study traumatic brain injury (TBI). Tissues cultured on SMEA remained viable for 19 days, and the electrodes were able to both stimulate and record neural tissue activity before, during and after stretching. Therefore SMEAs are able to bring together mechanical injury, electrophysiological recording and pharmacological studies. The SMEAs could serve as in vitro platforms for high throughput therapeutic screening and discovery for traumatic injury. The ability to reproducibly fabricate stretchable conductors using micro-fabrication technology will facilitate adoption by industry. The ability to understand the stretching mechanism will enable us to design more robust material systems. The SMEA prototypes demonstrate that stretchable conductors are practical, and their mechanical compatibility with biological systems also makes them candidates for use in biomedical devices.
Schieschke, Nils; Di Remigio, Roberto; Frediani, Luca; Heuser, Johannes; Höfener, Sebastian
2017-07-15
We present the explicit derivation of an approach to the multiscale description of molecules in complex environments that combines frozen-density embedding (FDE) with continuum solvation models, in particular the conductor-like screening model (COSMO). FDE provides an explicit atomistic description of molecule-environment interactions at reduced computational cost, while the outer continuum layer accounts for the effect of long-range isotropic electrostatic interactions. Our treatment is based on a variational Lagrangian framework, enabling rigorous derivations of ground- and excited-state response properties. As an example of the flexibility of the theoretical framework, we derive and discuss FDE + COSMO analytical molecular gradients for excited states within the Tamm-Dancoff approximation (TDA) and for ground states within second-order Møller-Plesset perturbation theory (MP2) and a second-order approximate coupled cluster with singles and doubles (CC2). It is shown how this method can be used to describe vertical electronic excitation (VEE) energies and Stokes shifts for uracil in water and carbostyril in dimethyl sulfoxide (DMSO), respectively. In addition, VEEs for some simplified protein models are computed, illustrating the performance of this method when applied to larger systems. The interaction terms between the FDE subsystem densities and the continuum can influence excitation energies up to 0.3 eV and, thus, cannot be neglected for general applications. We find that the net influence of the continuum in presence of the first FDE shell on the excitation energy amounts to about 0.05 eV for the cases investigated. The present work is an important step toward rigorously derived ab initio multilayer and multiscale modeling approaches. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Solvation effect on isomer stability and electronic structures of protonated serotonin
NASA Astrophysics Data System (ADS)
Omidyan, Reza; Amanollahi, Zohreh; Azimi, Gholamhassan
2017-07-01
Microsolvation effect on geometry and transition energies of protonated serotonin has been investigated by MP2 and CC2 quantum chemical methods. Also, conductor-like screening model, implemented recently in the MP2 and ADC(2) methods, was examined to address the bulk water environment's effect on the isomer stability and electronic transition energies of protonated serotonin. It has been predicted that the dipole moment of gas phase isomers plays the main role on the isomer stabilization in water solution and electronic transition shifts. Also, both red- and blue-shift effects have been predicted to take place on electronic transition energies, upon hydration.
Modeling of screening currents in coated conductor magnets containing up to 40000 turns
NASA Astrophysics Data System (ADS)
Pardo, E.
2016-08-01
Screening currents caused by varying magnetic fields degrade the homogeneity and stability of the magnetic fields created by REBCO coated conductor coils. They are responsible for the AC loss; which is also important for other power applications containing windings, such as transformers, motors and generators. Since real magnets contain coils exceeding 10000 turns, accurate modeling tools for this number of turns or above are necessary for magnet design. This article presents a fast numerical method to model coils with no loss of accuracy. We model a 10400-turn coil for its real number of turns and coils of up to 40000 turns with continuous approximation, which introduces negligible errors. The screening currents, the screening current induced field (SCIF) and the AC loss is analyzed in detail. The SCIF is at a maximum at the remnant state with a considerably large value. The instantaneous AC loss for an anisotropic magnetic-field dependent J c is qualitatively different than for a constant J c , although the loss per cycle is similar. Saturation of the magnetization currents at the end pancakes causes the maximum AC loss at the first ramp to increase with J c . The presented modeling tool can accurately calculate the SCIF and AC loss in practical computing times for coils with any number of turns used in real windings, enabling parameter optimization.
Predictive model for ionic liquid extraction solvents for rare earth elements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabda, Mariusz; Oleszek, Sylwia; Institute of Environmental Engineering of the Polish Academy of Sciences, ul. M. Sklodowskiej-Curie 34, 41-819, Zabrze
2015-12-31
The purpose of our study was to select the most effective ionic liquid extraction solvents for dysprosium (III) fluoride using a theoretical approach. Conductor-like Screening Model for Real Solvents (COSMO-RS), based on quantum chemistry and the statistical thermodynamics of predefined DyF{sub 3}-ionic liquid systems, was applied to reach the target. Chemical potentials of the salt were predicted in 4,400 different ionic liquids. On the base of these predictions set of ionic liquids’ ions, manifesting significant decrease of the chemical potentials, were selected. Considering the calculated physicochemical properties (hydrophobicity, viscosity) of the ionic liquids containing these specific ions, the most effectivemore » extraction solvents for liquid-liquid extraction of DyF{sub 3} were proposed. The obtained results indicate that the COSMO-RS approach can be applied to quickly screen the affinity of any rare earth element for a large number of ionic liquid systems, before extensive experimental tests.« less
Liang, Jiajie; Tong, Kwing; Pei, Qibing
2016-07-01
A water-based silver-nanowire (AgNW) ink is formulated for screen printing. Screen-printed AgNW patterns have uniform sharp edges, ≈50 μm resolution, and electrical conductivity as high as 4.67 × 10(4) S cm(-1) . The screen-printed AgNW patterns are used to fabricate a stretchable composite conductor, and a fully printed and intrinsically stretchable thin-film transistor array is also realized. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Microwave Imaging with Infrared 2-D Lock-in Amplifier
NASA Astrophysics Data System (ADS)
Chiyo, Noritaka; Arai, Mizuki; Tanaka, Yasuhiro; Nishikata, Atsuhiro; Maeno, Takashi
We have developed a 3-D electromagnetic field measurement system using 2-D lock-in amplifier. This system uses an amplitude modulated electromagnetic wave source to heat a resistive screen. A very small change of temperature on a screen illuminated with the modulated electromagnetic wave is measured using an infrared thermograph camera. In this paper, we attempted to apply our system to microwave imaging. By placing conductor patches in front of the resistive screen and illuminating with microwave, the shape of each conductor was clearly observed as the temperature difference image of the screen. In this way, the conductor pattern inside the non-contact type IC card could be visualized. Moreover, we could observe the temperature difference image reflecting the shape of a Konnyaku (a gelatinous food made from devil's-tonge starch) or a dried fishbone, both as non-conducting material resembling human body. These results proved that our method is applicable to microwave see-through imaging.
Liang, Jiajie; Tong, Kwing; Pei, Qibing
2016-05-09
Silver nanowire is a very promising material for fabricating compliant conductors which are essential for stretchable/wearable electronic devices. Screen printing is a cost-effective and scalable technology to fabricate large-area thin film coatings with modest pattern resolution. The biggest challenge to prepare a screen printable silver nanowire ink stems from the low viscosity of silver nanowire dispersions and that the addition of a thickening agent could dramatically increase the inter-nanowire contact resistance in the resulting coating. Herein, we report the synthesis of a water-based silver nanowire ink, which was formulated with low solid contents, high viscosity at 0.1 s -1 shearmore » rate, and appropriate rheological behavior suitable for screen printing. Silver nanowire coating patterns were screen printed with uniform sharp edges, ~50 μm resolution, and electrical conductivity as high as 4.67 × 10 4 S cm -1. The screen printed silver nanowires were then used to fabricate a composite conductor that retained a conductivity greater than 10,000 S cm -1 under 70% tensile strain. Fully printed and stretchable/wearable thin-film transistor arrays were also fabricated by employing the screen printed composite conductor as the source, drain, and gate, drop cast semiconducting carbon nanotubes as the channel, and a dielectric elastomer. The 10 × 6 thin-film transistor arrays had a fabrication yield of 91.7%, average mobility of 33.8 ± 3.7 cm 2V -1s -1, ON/OFF ratio ~1000, and remained stable during 1,000 cycles of wearing on and peeling off a glass tube with 5 mm diameter.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Jiajie; Tong, Kwing; Pei, Qibing
Silver nanowire is a very promising material for fabricating compliant conductors which are essential for stretchable/wearable electronic devices. Screen printing is a cost-effective and scalable technology to fabricate large-area thin film coatings with modest pattern resolution. The biggest challenge to prepare a screen printable silver nanowire ink stems from the low viscosity of silver nanowire dispersions and that the addition of a thickening agent could dramatically increase the inter-nanowire contact resistance in the resulting coating. Herein, we report the synthesis of a water-based silver nanowire ink, which was formulated with low solid contents, high viscosity at 0.1 s -1 shearmore » rate, and appropriate rheological behavior suitable for screen printing. Silver nanowire coating patterns were screen printed with uniform sharp edges, ~50 μm resolution, and electrical conductivity as high as 4.67 × 10 4 S cm -1. The screen printed silver nanowires were then used to fabricate a composite conductor that retained a conductivity greater than 10,000 S cm -1 under 70% tensile strain. Fully printed and stretchable/wearable thin-film transistor arrays were also fabricated by employing the screen printed composite conductor as the source, drain, and gate, drop cast semiconducting carbon nanotubes as the channel, and a dielectric elastomer. The 10 × 6 thin-film transistor arrays had a fabrication yield of 91.7%, average mobility of 33.8 ± 3.7 cm 2V -1s -1, ON/OFF ratio ~1000, and remained stable during 1,000 cycles of wearing on and peeling off a glass tube with 5 mm diameter.« less
Features of a SINDA/FLUINT model of a liquid oxygen supply line
NASA Astrophysics Data System (ADS)
Simmonds, Boris G.
1993-11-01
The modeling features used in a steady-state heat transfer problem using SINDA/FLUINT are described. The problem modeled is a 125 feet long, 3 inch diameter pipe, filled with liquid oxygen flow driven by a given pressure gradient. The pipe is fully insulated in five sections. Three sections of 1 inch thick spray-on foam and two sections of vacuum jacket. The model evaluates friction, turns losses and convection heat transfer between the fluid and the pipe wall. There is conduction through the foam insulation with temperature dependent thermal conductivity. The vacuum space is modeled with radiation and gas molecular conduction, if present, in the annular gap. Heat is transferred between the outer surface and surrounding ambient by natural convection and radiation; and, by axial conduction along the pipe and through the vacuum jacket spacers and welded seal flanges. The model makes extensive use of SINDA/FLUINT basic capabilities such as the GEN option for nodes and conductors (to generate groups of nodes or conductors), the SIV option (to generate single, temperature varying conductors), the SIM option (for multiple, temperature varying conductors) and the M HX macros for fluids (to generate strings of lumps, paths, and ties representing a diabatic duct). It calls subroutine CONTRN (returns the relative location in the G-array of a network conductor, given an actual conductor number) enabling an extensive manipulation of conductor (calculates an assignment of their values) with DO loops. Models like this illustrate to the new and even to the old SINDA/FLUINT user, features of the program that are not so obvious or known, and that are extremely handy when trying to take advantage of both, the automation of the DATA headers and make surgical modifications to specific parameters of the thermal or fluid elements in the OPERATIONS portion of the model.
Features of a SINDA/FLUINT model of a liquid oxygen supply line
NASA Technical Reports Server (NTRS)
Simmonds, Boris G.
1993-01-01
The modeling features used in a steady-state heat transfer problem using SINDA/FLUINT are described. The problem modeled is a 125 feet long, 3 inch diameter pipe, filled with liquid oxygen flow driven by a given pressure gradient. The pipe is fully insulated in five sections. Three sections of 1 inch thick spray-on foam and two sections of vacuum jacket. The model evaluates friction, turns losses and convection heat transfer between the fluid and the pipe wall. There is conduction through the foam insulation with temperature dependent thermal conductivity. The vacuum space is modeled with radiation and gas molecular conduction, if present, in the annular gap. Heat is transferred between the outer surface and surrounding ambient by natural convection and radiation; and, by axial conduction along the pipe and through the vacuum jacket spacers and welded seal flanges. The model makes extensive use of SINDA/FLUINT basic capabilities such as the GEN option for nodes and conductors (to generate groups of nodes or conductors), the SIV option (to generate single, temperature varying conductors), the SIM option (for multiple, temperature varying conductors) and the M HX macros for fluids (to generate strings of lumps, paths, and ties representing a diabatic duct). It calls subroutine CONTRN (returns the relative location in the G-array of a network conductor, given an actual conductor number) enabling an extensive manipulation of conductor (calculates an assignment of their values) with DO loops. Models like this illustrate to the new and even to the old SINDA/FLUINT user, features of the program that are not so obvious or known, and that are extremely handy when trying to take advantage of both, the automation of the DATA headers and make surgical modifications to specific parameters of the thermal or fluid elements in the OPERATIONS portion of the model.
Electronic processes in TTF-derived complexes studied by IR spectroscopy
NASA Astrophysics Data System (ADS)
Graja, Andrzej
2001-09-01
We focus our attention on the plasma-edge-like dispersion of the reflectance spectra of the selected bis(ethylenodithio)tetrathiafulvalene (BEDT-TTF)-derived organic conductors. The standard procedure to determine the electron transport parameters in low-dimensional organic conductors consists of fitting the appropriate theoretical models with the experimental reflectance data. This procedure provides us with basic information like plasma frequency, the optical effective mass of charge carriers, their number, mean free path and damping constant. Therefore, it is concluded that the spectroscopy is a powerful tool to study the electronic processes in conducting organic solids.
The performance of cable braids and terminations to lightning induced transients
NASA Technical Reports Server (NTRS)
Crofts, David
1991-01-01
The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.
Applicability of DFT model in reactive distillation
NASA Astrophysics Data System (ADS)
Staszak, Maciej
2017-11-01
The density functional theory (DFT) applicability to reactive distillation is discussed. Brief modeling techniques description of distillation and rectification with chemical reaction is provided as a background for quantum method usage description. The equilibrium and nonequilibrium distillation models are described for that purpose. The DFT quantum theory is concisely described. The usage of DFT in the modeling of reactive distillation is described in two parts. One of the fundamental and very important component of distillation modeling is vapor-liquid equilibrium description for which the DFT quantum approach can be used. The representative DFT models, namely COSMO-RS (Conductor like Screening Model for Real Solvents), COSMOSPACE (COSMO Surface Pair Activity Coefficient) and COSMO-SAC (SAC - segment activity coefficient) approaches are described. The second part treats the way in which the chemical reaction is described by means of quantum DFT method. The intrinsic reaction coordinate (IRC) method is described which is used to find minimum energy path of substrates to products transition. The DFT is one of the methods which can be used for that purpose. The literature data examples are provided which proves that IRC method is applicable for chemical reaction kinetics description.
Plasmonic transparent conductors
NASA Astrophysics Data System (ADS)
Liapis, Andreas C.; Sfeir, Matthew Y.; Black, Charles T.
2016-09-01
Many of today's technological applications, such as solar cells, light-emitting diodes, displays, and touch screens, require materials that are simultaneously optically transparent and electrically conducting. Here we explore transparent conductors based on the excitation of surface plasmons in nanostructured metal films. We measure both the optical and electrical properties of films perforated with nanometer-scale features and optimize the design parameters in order to maximize optical transmission without sacrificing electrical conductivity. We demonstrate that plasmonic transparent conductors can out-perform indium tin oxide in terms of both their transparency and their conductivity.
Method and apparatus for preparing multiconductor cable with flat conductors
NASA Technical Reports Server (NTRS)
Marcell, G. V. (Inventor)
1969-01-01
A method and apparatus for preparing flat conductor cable having a plurality of ribbon-like conductors disposed upon and adhesively bonded to the surface of a substrate is described. The conductors are brought into contact with the substrate surface, and while maintained in axial tension on said substrate, the combination is seated on a yieldably compressible layer to permit the conductor to become embedded into the surface of the substrate film.
Passos, Helena; Dinis, Teresa B V; Cláudio, Ana Filipa M; Freire, Mara G; Coutinho, João A P
2018-05-23
Aqueous biphasic systems (ABS) composed of ionic liquids (ILs) and conventional salts have been largely investigated and successfully used in separation processes, for which the determination of the corresponding ternary phase diagrams is a prerequisite. However, due the large number of ILs that can be prepared and their high structural versatility, it is impossible to experimentally cover and characterize all possible combinations of ILs and salts that may form ABS. The development of tools for the prediction and design of IL-based ABS is thus a crucial requirement. Based on a large compilation of experimental data, a correlation describing the formation of IL-based ABS is shown here, based on the hydrogen-bonding interaction energies of ILs (EHB) obtained by the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) and the molar entropy of hydration of the salt ions. The ability of the proposed model to predict the formation of novel IL-based ABS is further ascertained.
Sicaire, Anne-Gaëlle; Vian, Maryline; Fine, Frédéric; Joffre, Florent; Carré, Patrick; Tostain, Sylvain; Chemat, Farid
2015-01-01
The present study was designed to evaluate the performance of alternative bio-based solvents, more especially 2-methyltetrahydrofuran, obtained from crop’s byproducts for the substitution of petroleum solvents such as hexane in the extraction of fat and oils for food (edible oil) and non-food (bio fuel) applications. First a solvent selection as well as an evaluation of the performance was made with Hansen Solubility Parameters and the COnductor-like Screening MOdel for Realistic Solvation (COSMO-RS) simulations. Experiments were performed on rapeseed oil extraction at laboratory and pilot plant scale for the determination of lipid yields, extraction kinetics, diffusion modeling, and complete lipid composition in term of fatty acids and micronutrients (sterols, tocopherols and tocotrienols). Finally, economic and energetic evaluations of the process were conducted to estimate the cost of manufacturing using 2-methyltetrahydrofuran (MeTHF) as alternative solvent compared to hexane as petroleum solvent. PMID:25884332
Moncho, Salvador; Autschbach, Jochen
2010-01-12
A benchmark study for relativistic density functional calculations of NMR spin-spin coupling constants has been performed. The test set contained 47 complexes with heavy metal atoms (W, Pt, Hg, Tl, Pb) with a total of 88 coupling constants involving one or two heavy metal atoms. One-, two-, three-, and four-bond spin-spin couplings have been computed at different levels of theory (nonhybrid vs hybrid DFT, scalar vs two-component relativistic). The computational model was based on geometries fully optimized at the BP/TZP scalar relativistic zeroth-order regular approximation (ZORA) and the conductor-like screening model (COSMO) to include solvent effects. The NMR computations also employed the continuum solvent model. Computations in the gas phase were performed in order to assess the importance of the solvation model. The relative median deviations between various computational models and experiment were found to range between 13% and 21%, with the highest-level computational model (hybrid density functional computations including scalar plus spin-orbit relativistic effects, the COSMO solvent model, and a Gaussian finite-nucleus model) performing best.
Hong, Sukjoon; Yeo, Junyeob; Kim, Gunho; Kim, Dongkyu; Lee, Habeom; Kwon, Jinhyeong; Lee, Hyungman; Lee, Phillip; Ko, Seung Hwan
2013-06-25
We introduce a facile approach to fabricate a metallic grid transparent conductor on a flexible substrate using selective laser sintering of metal nanoparticle ink. The metallic grid transparent conductors with high transmittance (>85%) and low sheet resistance (30 Ω/sq) are readily produced on glass and polymer substrates at large scale without any vacuum or high-temperature environment. Being a maskless direct writing method, the shape and the parameters of the grid can be easily changed by CAD data. The resultant metallic grid also showed a superior stability in terms of adhesion and bending. This transparent conductor is further applied to the touch screen panel, and it is confirmed that the final device operates firmly under continuous mechanical stress.
NASA Astrophysics Data System (ADS)
Schacherer, C.; Kudymow, A.; Noe, M.
2008-02-01
Coated conductors are suitable for many power applications like motors, magnets and superconducting fault current limiters (SCFCLs). For their use in resistive SCFCLs main requirements are quench stability and resistance development above Tc. Several coated conductors are available with different kinds of stabilization like thickness or material of cap-layer and additional stabilization. The stabilization can vary and has a great influence on the quench stability and quench behaviour of a coated conductor. Thus, for the dimensioning of a superconducting current limiting element there is a need of reliable and universal design parameters. This paper presents experimental quench test results on several coated conductor types with different stabilization and geometry. The test results show that the dissipated energy during a quench is a very useful parameter for the SCFCL design.
System and method for sub-sea cable termination
Chen, Qin; Yin, Weijun; Zhang, Lili
2016-04-05
An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.
Elastically stretchable thin film conductors on an elastomeric substrate
NASA Astrophysics Data System (ADS)
Jones Harris, Joyelle Elizabeth
Imagine a large, flat screen television that can be rolled into a small cylinder after purchase in the store and then unrolled and mounted onto the wall of a home. The electronic devices within the television must be able to withstand large deformation and tensile strain. Consider a robot that is covered with an electronic skin that simulates human skin. The skin would enable the machine to lift an elderly person with care and sensitivity. The skin will endure repeated deformation with the highest tensile strains being experienced at the robot's joints. These applications and many others will benefit from stretchable electronic circuitry. While several different methods have been employed to create stretchable electronics, all methods use a common tool -- stretchable conductors. Therefore, the goal of this thesis work was to fabricate elastically stretchable conductors that can be used in stretchable electronics. We deposited Au thin films on an elastomeric substrate, and the resulting conductors remained electrically continuous when stretched by 30% and more. We developed photolithographic processes that can be used to pattern elastically stretchable conductors with a 10 mum resolution. We fabricated bi-level stretchable conductors that are separated by an elastomeric insulator and are electrically connected through via holes in the insulator. We applied our bi-level conductors to create a stretchable resistor-inductor-capacitor (RLC) circuit with a tunable resonant frequency. We also used stretchable conductors to measure action potentials in biological samples. This thesis describes the fabrication and application of our elastically stretchable conductors.
Size-Dependent Rupture Strain of Elastically Stretchable Metal Conductors
Graudejus, O.; Jia, Z.; Li, T.; Wagner, S.
2012-01-01
Experiments show that the rupture strain of gold conductors on elastomers decreases as the conductors are made long and narrow. Rupture is caused by the irreversible coalescence of microcracks into one long crack. A mechanics model identifies a critical crack length ℓcr, above which the long crack propagates across the entire conductor width. ℓcr depends on the fracture toughness of the gold film and the width of the conductor. The model provides guidance for the design of highly stretchable conductors. PMID:22773917
Solubility prediction, solvate and cocrystal screening as tools for rational crystal engineering.
Loschen, Christoph; Klamt, Andreas
2015-06-01
The fact that novel drug candidates are becoming increasingly insoluble is a major problem of current drug development. Computational tools may address this issue by screening for suitable solvents or by identifying potential novel cocrystal formers that increase bioavailability. In contrast to other more specialized methods, the fluid phase thermodynamics approach COSMO-RS (conductor-like screening model for real solvents) allows for a comprehensive treatment of drug solubility, solvate and cocrystal formation and many other thermodynamics properties in liquids. This article gives an overview of recent COSMO-RS developments that are of interest for drug development and contains several new application examples for solubility prediction and solvate/cocrystal screening. For all property predictions COSMO-RS has been used. The basic concept of COSMO-RS consists of using the screening charge density as computed from first principles calculations in combination with fast statistical thermodynamics to compute the chemical potential of a compound in solution. The fast and accurate assessment of drug solubility and the identification of suitable solvents, solvate or cocrystal formers is nowadays possible and may be used to complement modern drug development. Efficiency is increased by avoiding costly quantum-chemical computations using a database of previously computed molecular fragments. COSMO-RS theory can be applied to a range of physico-chemical properties, which are of interest in rational crystal engineering. Most notably, in combination with experimental reference data, accurate quantitative solubility predictions in any solvent or solvent mixture are possible. Additionally, COSMO-RS can be extended to the prediction of cocrystal formation, which results in considerable predictive accuracy concerning coformer screening. In a recent variant costly quantum chemical calculations are avoided resulting in a significant speed-up and ease-of-use. © 2015 Royal Pharmaceutical Society.
NASA Astrophysics Data System (ADS)
Brighenti, A.; Bonifetto, R.; Isono, T.; Kawano, K.; Russo, G.; Savoldi, L.; Zanino, R.
2017-12-01
The ITER Central Solenoid Model Coil (CSMC) is a superconducting magnet, layer-wound two-in-hand using Nb3Sn cable-in-conduit conductors (CICCs) with the central channel typical of ITER magnets, cooled with supercritical He (SHe) at ∼4.5 K and 0.5 MPa, operating for approximately 15 years at the National Institutes for Quantum and Radiological Science and Technology in Naka, Japan. The aim of this work is to give an overview of the issues related to the hydraulic performance of the three different CICCs used in the CSMC based on the extensive experimental database put together during the past 15 years. The measured hydraulic characteristics are compared for the different test campaigns and compared also to those coming from the tests of short conductor samples when available. It is shown that the hydraulic performance of the CSMC conductors did not change significantly in the sequence of test campaigns with more than 50 cycles up to 46 kA and 8 cooldown/warmup cycles from 300 K to 4.5 K. The capability of the correlations typically used to predict the friction factor of the SHe for the design and analysis of ITER-like CICCs is also shown.
Films of Carbon Nanomaterials for Transparent Conductors
Ho, Xinning; Wei, Jun
2013-01-01
The demand for transparent conductors is expected to grow rapidly as electronic devices, such as touch screens, displays, solid state lighting and photovoltaics become ubiquitous in our lives. Doped metal oxides, especially indium tin oxide, are the commonly used materials for transparent conductors. As there are some drawbacks to this class of materials, exploration of alternative materials has been conducted. There is an interest in films of carbon nanomaterials such as, carbon nanotubes and graphene as they exhibit outstanding properties. This article reviews the synthesis and assembly of these films and their post-treatment. These processes determine the film performance and understanding of this platform will be useful for future work to improve the film performance. PMID:28809267
Physical and Electronic Isolation of Carbon Nanotube Conductors
NASA Technical Reports Server (NTRS)
OKeeffe, James; Biegel, Bryan (Technical Monitor)
2001-01-01
Multi-walled nanotubes are proposed as a method to electrically and physically isolate nanoscale conductors from their surroundings. We use tight binding (TB) and density functional theory (DFT) to simulate the effects of an external electric field on multi-wall nanotubes. Two categories of multi-wall nanotube are investigated, those with metallic and semiconducting outer shells. In the metallic case, simulations show that the outer wall effectively screens the inner core from an applied electric field. This offers the ability to reduce crosstalk between nanotube conductors. A semiconducting outer shell is found not to perturb an electric field incident on the inner core, thereby providing physical isolation while allowing the tube to remain electrically coupled to its surroundings.
Directional detector of gamma rays
Cox, Samson A.; Levert, Francis E.
1979-01-01
A directional detector of gamma rays comprises a strip of an electrical cuctor of high atomic number backed with a strip of a second electrical conductor of low atomic number. These elements are enclosed within an electrical conductor that establishes an electrical ground, maintains a vacuum enclosure and screens out low-energy gamma rays. The detector exhibits a directional sensitivity marked by an increased output in the favored direction by a factor of ten over the output in the unfavored direction.
Geometries of geoelectrical structures in central Tibetan Plateau from INDEPTH magnetotelluric data
NASA Astrophysics Data System (ADS)
Vozar, J.; Jones, A. G.; Le Pape, F.
2012-12-01
Magnetotelluric (MT) data collected on N-S profiles crossing the Banggong-Nujiang Suture (BNS), which separates the Qiangtang and Lhasa Terranes in central Tibet, as a part of InterNational DEep Profiling of Tibet and the Himalaya project (INDEPTH) are modeled by 2D, 3D inversion codes and 1D petro-physical package LitMod. The modeling exhibits regional resistive and conductive structures correlated with ShuangHu Suture, Tanggula Mountains and strike-slip faults like BengCo-Jiali fault in the south. The BNS is not manifested in the geoelectrical models as a strong crustal regional structure. The strike direction azimuth of mid and lower crustal structures estimated from horizontal slices from 3D modeling (N110°E) is slightly different from one estimated by 2D strike analysis (N100°E). Orientation of crustal structures is perpendicular to convergence direction in this area. The deepest lower crustal conductors are correlated to areas with maximum Moho depth obtained from satellite gravity data. The anisotropic 2D modeling reveals that lower crustal conductor in Lhasa Terrane is anisotropic. This anisotropy can be interpreted as a proof for crustal channel flow below Lhasa Terrane. But same Lhasa lower crust conductor from isotropic 3D modeling can be interpreted more likely as 3D lower Indian crust structure, located to the east from line 500, than geoelectrical anisotropic crustal flow. From deep electromagnetic sounding, supported by independent integrated petro-physical investigation, we can estimate the next upper-mantle conductive layer at depths from 200 km to 250 km below the Lhasa Terrane and less resistive Tibetan lithosphere below the Qiangtang Terrane with conductive upper-mantle in depths about 120 km.
Use of Second Generation Coated Conductors for Efficient Shielding of dc Magnetic Fields (Postprint)
2010-07-15
layer of superconducting film, can attenuate an external magnetic field of up to 5 mT by more than an order of magnitude. For comparison purposes...appears to be especially promising for the realization of large scale high-Tc superconducting screens. 15. SUBJECT TERMS magnetic screens, current...realization of large scale high-Tc superconducting screens. © 2010 American Institute of Physics. doi:10.1063/1.3459895 I. INTRODUCTION Magnetic screening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irminger, Philip; Starke, Michael R; Dimitrovski, Aleksandar D
2014-01-01
Power system equipment manufacturers and researchers continue to experiment with novel overhead electric conductor designs that support better conductor performance and address congestion issues. To address the technology gap in testing these novel designs, Oak Ridge National Laboratory constructed the Powerline Conductor Accelerated Testing (PCAT) facility to evaluate the performance of novel overhead conductors in an accelerated fashion in a field environment. Additionally, PCAT has the capability to test advanced sensors and measurement methods for accessing overhead conductor performance and condition. Equipped with extensive measurement and monitoring devices, PCAT provides a platform to improve/validate conductor computer models and assess themore » performance of novel conductors. The PCAT facility and its testing capabilities are described in this paper.« less
Mechanistic insights related to the design and construction of lithium single ion conductors
NASA Astrophysics Data System (ADS)
Spahlinger, Gregory
Lithium single ion conductors are a class of electrolytes, typically designed for lithium ion batteries, with the potential to improve the performance of these batteries. The benefits of single ion conductors arise out of the fact that their immobile anions are not capable of concentrating near the anode of the battery, causing an increase in resistance as the battery is discharged. Unfortunately lithium single ion conductors suffer severe drawbacks in their conductivity which have been attributed to diverse causes. Because of the low success rate of single ion conductors in the literature and previous work in the Baker group, I have chosen to investigate mechanistic questions related to the design and construction of these materials, without engineering new materials. An attractive design strategy for the screening of immobile anion moieties for single ion conductors would be the use of the copper catalyzed alkyne azide (CUAAC) "click" reaction in order to efficiently introduce anions onto a polymer or nanoparticle support in a way that is efficient and tunable. A variable added by this strategy would be the presence of a 1,2,3-triazole moiety which is without any significant precedent in the lithium ion electrolyte literature. In order to assess the impact of the triazole in on the conductivity of an electrolyte a series of model compounds were synthesized containing a variable number of triazoles in an otherwise poly(ethylene glycol) like oligomer chain. The model compounds were subjected to differential scanning calorimetry, electrochemical impedance spectroscopy, and in one case single crystal X-ray diffraction, and solvent shells were modeled for lithium with and without triazoles using ab initio quantum chemistry calculations. It was concluded that the triazole is not significantly stronger than an ether oxygen as a ligand in the electrolytes, however the triazole has a substantial dipole which exerts some deleterious effects on the conductivity, leading to an increase in the Arrhenius activation energy for the process. These effects are balanced by an increase in the pre-exponential factor which leads to "compensation behavior" due to the dependence of that quantity on the dipole density in the material. The observed effect is one of a lower conductivity for the model compounds relative to poly(ethylene glycol)dimethyl ether 500 at room temperature, which converges to roughly the same conductivity around 80 °C. In synthetic studies, attempts were made to synthesize N-triflylpropanesultam (TPS) a five membered heterocycle whose nucleophilic ring opening would yield a desirable anion for use in single ion conductors. TPS proved to be significantly more difficult to open than expected, which prompted a computational study. In order to study the nucleofugality of polyatomic anionic leaving groups derived from oxygen and nitrogen, a contingent of 19 methylating agents consisting of amines or alcohols activated with carbonyl or sulfonyl substituents has been examined via ab initio calculations. Gas phase activation energies for alkylation of ammonia, and gas phase methyl cation affinitys were calculated. It was found that polyatomic anionic leaving groups derived from nitrogen will have higher activation energies for Menshutkin (SN2) alkylation even when they have similar methyl cation affinities. This inherent deficit in the nucleofugality of nitrogen derived leaving groups appears to be a result of the way bond cleavage is synchronized with bond formation to the incoming ammonia nucleophile. Additionally the second sulfonyl group present in a sulfonimide appears to be less effective at activating nitrogen due to a preference for tetrahedral geometries at nitrogen in the transition states of sulfonamide groups. Optimal delocalization of electron density is therefore frustrated due to the symmetry of the leaving group.
Electrical screening procedure for solid ionic conductors
NASA Technical Reports Server (NTRS)
Kautz, H. E.; Singer, J.; Fielder, W. L.; Fordyce, J. S.
1973-01-01
An electrical screening method has been developed for preliminary evaluation of polycrystalline specimens of candidates for use as solid ionic conductive electrolytes in batteries. The procedure measures dielectric loss and capacitance, from which are calculated an ac conductivity attributed provisionally to ions and an activation energy for that conductivity. Electronic conductivity is directly measured. The screening procedure applied to sodium beta-alumina yielded acceptable values for conductivity and activation energy.
NASA Astrophysics Data System (ADS)
Sendek, Austin D.; Yang, Qian; Cubuk, Ekin D.; Duerloo, Karel-Alexander N.; Cui, Yi; Reed, Evan J.
We present a new type of large-scale computational screening approach for identifying promising candidate materials for solid state electrolytes for lithium ion batteries that is capable of screening all known lithium containing solids. To predict the likelihood of a candidate material exhibiting high lithium ion conductivity, we leverage machine learning techniques to train an ionic conductivity classification model using logistic regression based on experimental measurements reported in the literature. This model, which is built on easily calculable atomistic descriptors, provides new insight into the structure-property relationship for superionic behavior in solids and is approximately one million times faster to evaluate than DFT-based approaches to calculating diffusion coefficients or migration barriers. We couple this model with several other technologically motivated heuristics to reduce the list of candidate materials from the more than 12,000 known lithium containing solids to 21 structures that show promise as electrolytes, few of which have been examined experimentally. Our screening utilizes structures and electronic information contained in the Materials Project database. This work is supported by an Office of Technology Licensing Fellowship through the Stanford Graduate Fellowship Program and a seed Grant from the TomKat Center for Sustainable Energy at Stanford.
Study, selection, and preparation of solid cationic conductors
NASA Technical Reports Server (NTRS)
Roth, W. L.; Mitoff, S. P.; King, R. N.
1972-01-01
Crystal chemical principles and transport theory were used to predict structures and specific compounds which might find application as solid electrolytes in rechargeable high energy and high power density batteries operating at temperatures less than 200 C. More than twenty compounds were synthesized or obtained and screened by nuclear magnetic resonance and conductivity. Many were densified by sintering or hot pressing. Encouraging results were obtained for nine of these materials but none have yet been good ionic conductors at low temperature.
NASA Astrophysics Data System (ADS)
Dondurur, Derman
2005-11-01
The Normalized Full Gradient (NFG) method was proposed in the mid 1960s and was generally used for the downward continuation of the potential field data. The method eliminates the side oscillations which appeared on the continuation curves when passing through anomalous body depth. In this study, the NFG method was applied to Slingram electromagnetic anomalies to obtain the depth of the anomalous body. Some experiments were performed on the theoretical Slingram model anomalies in a free space environment using a perfectly conductive thin tabular conductor with an infinite depth extent. The theoretical Slingram responses were obtained for different depths, dip angles and coil separations, and it was observed from NFG fields of the theoretical anomalies that the NFG sections yield the depth information of top of the conductor at low harmonic numbers. The NFG sections consisted of two main local maxima located at both sides of the central negative Slingram anomalies. It is concluded that these two maxima also locate the maximum anomaly gradient points, which indicates the depth of the anomaly target directly. For both theoretical and field data, the depth of the maximum value on the NFG sections corresponds to the depth of the upper edge of the anomalous conductor. The NFG method was applied to the in-phase component and correct depth estimates were obtained even for the horizontal tabular conductor. Depth values could be estimated with a relatively small error percentage when the conductive model was near-vertical and/or the conductor depth was larger.
A Mathematical Evaluation of the Core Conductor Model
Clark, John; Plonsey, Robert
1966-01-01
This paper is a mathematical evaluation of the core conductor model where its three dimensionality is taken into account. The problem considered is that of a single, active, unmyelinated nerve fiber situated in an extensive, homogeneous, conducting medium. Expressions for the various core conductor parameters have been derived in a mathematically rigorous manner according to the principles of electromagnetic theory. The purpose of employing mathematical rigor in this study is to bring to light the inherent assumptions of the one dimensional core conductor model, providing a method of evaluating the accuracy of this linear model. Based on the use of synthetic squid axon data, the conclusion of this study is that the linear core conductor model is a good approximation for internal but not external parameters. PMID:5903155
NASA Astrophysics Data System (ADS)
Patel, Utkarsh R.; Triverio, Piero
2016-09-01
An accurate modeling of skin effect inside conductors is of capital importance to solve transmission line and scattering problems. This paper presents a surface-based formulation to model skin effect in conductors of arbitrary cross section, and compute the per-unit-length impedance of a multiconductor transmission line. The proposed formulation is based on the Dirichlet-Neumann operator that relates the longitudinal electric field to the tangential magnetic field on the boundary of a conductor. We demonstrate how the surface operator can be obtained through the contour integral method for conductors of arbitrary shape. The proposed algorithm is simple to implement, efficient, and can handle arbitrary cross-sections, which is a main advantage over the existing approach based on eigenfunctions, which is available only for canonical conductor's shapes. The versatility of the method is illustrated through a diverse set of examples, which includes transmission lines with trapezoidal, curved, and V-shaped conductors. Numerical results demonstrate the accuracy, versatility, and efficiency of the proposed technique.
Topological properties of a self-assembled electrical network via ab initio calculation
NASA Astrophysics Data System (ADS)
Stephenson, C.; Lyon, D.; Hübler, A.
2017-02-01
Interacting electrical conductors self-assemble to form tree like networks in the presence of applied voltages or currents. Experiments have shown that the degree distribution of the steady state networks are identical over a wide range of network sizes. In this work we develop a new model of the self-assembly process starting from the underlying physical interaction between conductors. In agreement with experimental results we find that for steady state networks, our model predicts that the fraction of endpoints is a constant of 0.252, and the fraction of branch points is 0.237. We find that our model predicts that these scaling properties also hold for the network during the approach to the steady state as well. In addition, we also reproduce the experimental distribution of nodes with a given Strahler number for all steady state networks studied.
NASA Astrophysics Data System (ADS)
Du, Patrick Y.; Zhou, Qi-Bin
This paper presents an analysis of lightning-induced magnetic fields in a building. The building of concern is protected by the lightning protection system with an insulated down conductor. In this paper a system model for metallic structure of the building is constructed first using the circuit approach. The circuit model of the insulated down conductor is discussed extensively, and explicit expressions of the circuit parameters are presented. The system model was verified experimentally in the laboratory. The modeling approach is applied to analyze the impulse magnetic fields in a full-scale building during a direct lightning strike. It is found that the impulse magnetic field is significantly high near the down conductor. The field is attenuated if the down conductor is moved to a column in the building. The field can be reduced further if the down conductor is housed in an earthed metal pipe. Recommendations for protecting critical equipment against lightning-induced magnetic fields are also provided in the paper.
Sanabria, Charlie; Lee, Peter J.; Starch, William; ...
2016-05-31
As part of the ITER conductor qualification process, 3 m long Cable-in-Conduit Conductors (CICCs) were tested at the SULTAN facility under conditions simulating ITER operation so as to establish the current sharing temperature, T cs, as a function of multiple full Lorentz force loading cycles. After a comprehensive evaluation of both the Toroidal Field (TF) and the Central Solenoid (CS) conductors, it was found that T cs degradation was common in long twist pitch TF conductors while short twist pitch CS conductors showed some T cs increase. However, one kind of TF conductors containing superconducting strand fabricated by the Bochvarmore » Institute of Inorganic Materials (VNIINM) avoided T cs degradation despite having long twist pitch. In our earlier metallographic autopsies of long and short twist pitch CS conductors, we observed a substantially greater transverse strand movement under Lorentz force loading for long twist pitch conductors, while short twist pitch conductors had negligible transverse movement. With help from the literature, we concluded that the transverse movement was not the source of T cs degradation but rather an increase of the compressive strain in the Nb 3Sn filaments possibly induced by longitudinal movement of the wires. Like all TF conductors this TF VNIINM conductor showed large transverse motions under Lorentz force loading, but Tcs actually increased, as in all short twist pitch CS conductors. We here propose that the high surface roughness of the VNIINM strand may be responsible for the suppression of the compressive strain enhancement (characteristic of long twist pitch conductors). Furthermore, it appears that increasing strand surface roughness could improve the performance of long twist pitch CICCs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanabria, Charlie; Lee, Peter J.; Starch, William
As part of the ITER conductor qualification process, 3 m long Cable-in-Conduit Conductors (CICCs) were tested at the SULTAN facility under conditions simulating ITER operation so as to establish the current sharing temperature, T cs, as a function of multiple full Lorentz force loading cycles. After a comprehensive evaluation of both the Toroidal Field (TF) and the Central Solenoid (CS) conductors, it was found that T cs degradation was common in long twist pitch TF conductors while short twist pitch CS conductors showed some T cs increase. However, one kind of TF conductors containing superconducting strand fabricated by the Bochvarmore » Institute of Inorganic Materials (VNIINM) avoided T cs degradation despite having long twist pitch. In our earlier metallographic autopsies of long and short twist pitch CS conductors, we observed a substantially greater transverse strand movement under Lorentz force loading for long twist pitch conductors, while short twist pitch conductors had negligible transverse movement. With help from the literature, we concluded that the transverse movement was not the source of T cs degradation but rather an increase of the compressive strain in the Nb 3Sn filaments possibly induced by longitudinal movement of the wires. Like all TF conductors this TF VNIINM conductor showed large transverse motions under Lorentz force loading, but Tcs actually increased, as in all short twist pitch CS conductors. We here propose that the high surface roughness of the VNIINM strand may be responsible for the suppression of the compressive strain enhancement (characteristic of long twist pitch conductors). Furthermore, it appears that increasing strand surface roughness could improve the performance of long twist pitch CICCs.« less
Mintzberg, H
1998-01-01
The orchestra conductor is a popular metaphor for managers today--up there on the podium in complete control. But that image may be misleading, says Henry Mintzberg, who recently spent a day with Bramwell Tovey, conductor of the Winnipeg Symphony Orchestra, in order to explore the metaphor. He found that Tovey does not operate like an absolute ruler but practices instead what Mintzberg calls covert leadership. Covert leadership means managing with a sense of nuances, constraints, and limitations. When a manager like Tovey guides an organization, he leads without seeming to, without his people being fully aware of all that he is doing. That's because in this world of professionals, a leader is not completely powerless--but neither does he have absolute control over others. As knowledge work grows in importance, the way an orchestra conductor really operates may serve as a good model for managers in a wide range of businesses. For example, Mintzberg found that Tovey does a lot more hands-on work than one might expect. More like a first-line supervisor than a hands-off executive, he takes direct and personal charge of what is getting done. In dealing with his musicians, his focus is on inspiring them, not empowering them. Like other professionals, the musicians don't need to be empowered--they're already secure in what they know and can do--but they do need to be infused with energy for the tasks at hand. This is the role of the covert leader: to act quietly and unobtrusively in order to exact not obedience but inspired performance.
Liu, Jie; Liang, WanZhen
2013-01-14
This work extends our previous works [J. Liu and W. Z. Liang, J. Chem. Phys. 135, 014113 (2011); J. Liu and W. Z. Liang, J. Chem. Phys. 135, 184111 (2011)] on analytical excited-state Hessian within the framework of time-dependent density functional theory (TDDFT) to couple with a conductor-like polarizable continuum model (CPCM). The formalism, implementation, and application of analytical first and second energy derivatives of TDDFT/CPCM excited state with respect to the nuclear and electric perturbations are presented. Their performances are demonstrated by the calculations of excitation energies, excited-state geometries, and harmonic vibrational frequencies for a number of benchmark systems. The calculated results are in good agreement with the corresponding experimental data or other theoretical calculations, indicating the reliability of the current computer implementation of the developed algorithms. Then we made some preliminary applications to calculate the resonant Raman spectrum of 4-hydroxybenzylidene-2,3-dimethyl-imidazolinone in ethanol solution and the infrared spectra of ground and excited states of 9-fluorenone in methanol solution.
NASA Astrophysics Data System (ADS)
Cao, Wenzhe; Görrn, Patrick; Wagner, Sigurd
2011-05-01
The electrical resistance of gold film conductors on polydimethyl siloxane substrates at stages of uniaxial stretching is measured and modeled. The surface area of a gold conductor is assumed constant during stretching so that the exposed substrate takes up all strain. Sheet resistances are calculated from frames of scanning electron micrographs by numerically solving for the electrical potentials of all pixels in a frame. These sheet resistances agree sufficiently well with values measured on the same conductors to give credence to the model of a stretchable network of gold links defined by microcracks.
Transparent conductors based on microscale/nanoscale materials for high performance devices
NASA Astrophysics Data System (ADS)
Gao, Tongchuan
Transparent conductors are important as the top electrode for a variety of optoelectronic devices, including solar cells, light-emitting diodes (LEDs), at panel displays, and touch screens. Doped indium tin oxide (ITO) thin films are the predominant transparent conductor material. However, ITO thin films are brittle, making them unsuitable for the emerging flexible devices, and suffer from high material and processing cost. In my thesis, we developed a variety of transparent conductors toward a performance comparable with or superior to ITO thin films, with lower cost and potential for scalable manufacturing. Metal nanomesh (NM), hierarchical graphene/metal microgrid (MG), and hierarchical metal NM/MG materials were investigated. Simulation methods were used as a powerful tool to predict the transparency and sheet resistance of the transparent conductors by solving Maxwell's equations and Poisson's equation. Affordable and scalable fabrication processes were developed thereafter. Transparent conductors with over 90% transparency and less than 10 O/square sheet resistance were successfully fabricated on both rigid and flexible substrates. Durability tests, such as bending, heating and tape tests, were carried out to evaluate the robustness of the samples. Haze factor, which characterizes how blurry a transparent conductor appears, was also studied in-depth using analytical calculation and numerical simulation. We demonstrated a tunable haze factor for metal NM transparent conductors and analyzed the principle for tuning the haze factor. Plasmonic effects, excited by some transparent conductors, can lead to enhanced performance in photovoltaic devices. We systematically studied the effect of incorporating metal NM into ultrathin film silicon solar cells using numerical simulation, with the aid of optimization algorithms to reduce the optimization time. Mechanisms contributing to the enhanced performance were then identified and analyzed. Over 72% enhancement in short-circuit current-density was demonstrated by the optimal solar cell compared with 300-nm-thick Si solar cell with antireflection coating and silver back reflector.
NASA Technical Reports Server (NTRS)
Malroy, Eric T.
2007-01-01
The programs, arrays and logic structure were developed to enable the dynamic update of conductors in thermal desktop. The MatLab program FMHTPRE.m processes the Thermal Desktop conductors and sets up the arrays. The user needs to manually copy portions of the output to different input regions in Thermal Desktop. Also, Fortran subroutines are provided that perform the actual updates to the conductors. The subroutines are setup for helium gas, but the equations can be modified for other gases. The maximum number of free molecular conductors allowed is 10,000 for a given radiation task. Additional radiation tasks for FMHT can be generated to account for more conductors. Modifications to the Fortran subroutines may be warranted, when the mode of heat transfer is in the mixed or continuum mode. The FMHT Thermal Desktop model should be activated by using the "Case Set Manager" once the model is setup. Careful setup of the model is needed to avoid excessive solve times.
High current capacity electrical connector
Bettis, Edward S.; Watts, Harry L.
1976-01-13
An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a "sandwiched" configuration in which a conductor plate contacts the busses along major surfaces thereof clamped between two stainless steel backing plates. The conductor plate is provided with a plurality of contact buttons affixed therein in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors.
An oppositely charged insect exclusion screen with gap-free multiple electric fields
NASA Astrophysics Data System (ADS)
Matsuda, Yoshinori; Kakutani, Koji; Nonomura, Teruo; Kimbara, Junji; Kusakari, Shin-ichi; Osamura, Kazumi; Toyoda, Hideyoshi
2012-12-01
An electric field screen was constructed to examine insect attraction mechanisms in multiple electric fields generated inside the screen. The screen consisted of two parallel insulated conductor wires (ICWs) charged with equal but opposite voltages and two separate grounded nets connected to each other and placed on each side of the ICW layer. Insects released inside the fields were charged either positively or negatively as a result of electricity flow from or to the insect, respectively. The force generated between the charged insects and opposite ICW charges was sufficient to capture all insects.
Study on galloping behavior of iced eight bundle conductor transmission lines
NASA Astrophysics Data System (ADS)
Zhou, Linshu; Yan, Bo; Zhang, Liang; Zhou, Song
2016-02-01
Wind tunnel test was carried out to obtain the aerodynamic coefficients of an eight bundle conductor accreted with crescent-shaped ice. A user-defined cable element with torsional degree of freedom is developed in ABAQUS software to capture the torsional deformation of the iced conductors during galloping. By means of the user-defined cable element, different damping ratios in in-plane, out-of-plane and torsional directions of the conductors can be defined and the aerodynamic forces varying with their motion status can be exerted on the conductors conveniently when ABAQUS is used to simulate galloping of transmission lines. A wind tunnel test to model galloping of an iced eight bundle conductor segment was carried out, and the validity of the numerical simulation method is demonstrated by the agreement of the galloping orbit of the bundle conductor segment model recorded in the test and that by the numerical simulation. Furthermore, galloping behavior, including dynamic responses, galloping orbits, frequencies, vibration modes and amplitudes, of typical iced eight bundle conductor transmission lines in the cases of different span lengths, initial tensions in sub-conductors, wind velocities, angles of wind attack and damping ratios is studied, and the galloping behavior of the lines with internal resonance conditions is discussed. The obtained results may provide a fundamental tool for the development of anti-galloping techniques of eight bundle conductor transmission lines.
The contribution of phosphate–phosphate repulsions to the free energy of DNA bending
Range, Kevin; Mayaan, Evelyn; Maher, L. J.; York, Darrin M.
2005-01-01
DNA bending is important for the packaging of genetic material, regulation of gene expression and interaction of nucleic acids with proteins. Consequently, it is of considerable interest to quantify the energetic factors that must be overcome to induce bending of DNA, such as base stacking and phosphate–phosphate repulsions. In the present work, the electrostatic contribution of phosphate–phosphate repulsions to the free energy of bending DNA is examined for 71 bp linear and bent-form model structures. The bent DNA model was based on the crystallographic structure of a full turn of DNA in a nucleosome core particle. A Green's function approach based on a linear-scaling smooth conductor-like screening model was applied to ascertain the contribution of individual phosphate–phosphate repulsions and overall electrostatic stabilization in aqueous solution. The effect of charge neutralization by site-bound ions was considered using Monte Carlo simulation to characterize the distribution of ion occupations and contribution of phosphate repulsions to the free energy of bending as a function of counterion load. The calculations predict that the phosphate–phosphate repulsions account for ∼30% of the total free energy required to bend DNA from canonical linear B-form into the conformation found in the nucleosome core particle. PMID:15741179
A new percolation model for composite solid electrolytes and dispersed ionic conductors
NASA Astrophysics Data System (ADS)
Risyad Hasyim, Muhammad; Lanagan, Michael T.
2018-02-01
Composite solid electrolytes (CSEs) including conductor/insulator composites known as dispersed ionic conductors (DICs) have motivated the development of novel percolation models that describe their conductivity. Despite the long history, existing models lack in one or more key areas: (1) rigorous foundation for their physical theory, (2) explanation for non-universal conductor-insulator transition, (3) classification of DICs, and (4) extension to frequency-domain. This work describes a frequency-domain effective medium approximation (EMA) of a bond percolation model for CSEs. The EMA is derived entirely from Maxwell’s equations and contains basic microstructure parameters. The model was applied successfully to several composite systems from literature. Simulations and fitting of literature data address these key areas and illustrate the interplay between space charge layer properties and bulk microstructure.
Effect of conductor geometry on source localization: Implications for epilepsy studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlitt, H.; Heller, L.; Best, E.
1994-07-01
We shall discuss the effects of conductor geometry on source localization for applications in epilepsy studies. The most popular conductor model for clinical MEG studies is a homogeneous sphere. However, several studies have indicated that a sphere is a poor model for the head when the sources are deep, as is the case for epileptic foci in the mesial temporal lobe. We believe that replacing the spherical model with a more realistic one in the inverse fitting procedure will improve the accuracy of localizing epileptic sources. In order to include a realistic head model in the inverse problem, we mustmore » first solve the forward problem for the realistic conductor geometry. We create a conductor geometry model from MR images, and then solve the forward problem via a boundary integral equation for the electric potential due to a specified primary source. One the electric potential is known, the magnetic field can be calculated directly. The most time-intensive part of the problem is generating the conductor model; fortunately, this needs to be done only once for each patient. It takes little time to change the primary current and calculate a new magnetic field for use in the inverse fitting procedure. We present the results of a series of computer simulations in which we investigate the localization accuracy due to replacing the spherical model with the realistic head model in the inverse fitting procedure. The data to be fit consist of a computer generated magnetic field due to a known current dipole in a realistic head model, with added noise. We compare the localization errors when this field is fit using a spherical model to the fit using a realistic head model. Using a spherical model is comparable to what is usually done when localizing epileptic sources in humans, where the conductor model used in the inverse fitting procedure does not correspond to the actual head.« less
Mechanism of Superconductivity in Quasi-Two-Dimensional Organic Conductor β-(BDA-TTP) Salts
NASA Astrophysics Data System (ADS)
Nonoyama, Yoshito; Maekawa, Yukiko; Kobayashi, Akito; Suzumura, Yoshikazu; Ito, Hiroshi
2008-09-01
We investigate theoretically the superconductivity of two-dimensional organic conductors, β-(BDA-TTP)2SbF6 and β-(BDA-TTP)2AsF6, to understand the role of the spin and charge fluctuations. The transition temperature is estimated by applying random phase approximation to an extended Hubbard model wherein realistic transfer energies are estimated by extended Hückel calculation. We find a gapless superconducting state with a dxy-like symmetry, which is consistent with the experimental results obtained by specific heat and scanning tunneling microscope. In the present model with an effectively half-filled triangular lattice, spin fluctuation competes with charge fluctuation as a mechanism of pairing interaction since both fluctuations have the same characteristic momentum q=(π,0) for V being smaller than U. This is in contrast to a model with a quarter-filled square lattice, wherein both fluctuations contribute cooperatively to pairing interaction due to fluctuations having different characteristic momenta. The resultant difference in the superconductivity of these two materials is also discussed.
Polarizable Molecular Dynamics in a Polarizable Continuum Solvent
Lipparini, Filippo; Lagardère, Louis; Raynaud, Christophe; Stamm, Benjamin; Cancès, Eric; Mennucci, Benedetta; Schnieders, Michael; Ren, Pengyu; Maday, Yvon; Piquemal, Jean-Philip
2015-01-01
We present for the first time scalable polarizable molecular dynamics (MD) simulations within a polarizable continuum solvent with molecular shape cavities and exact solution of the mutual polarization. The key ingredients are a very efficient algorithm for solving the equations associated with the polarizable continuum, in particular, the domain decomposition Conductor-like Screening Model (ddCOSMO), a rigorous coupling of the continuum with the polarizable force field achieved through a robust variational formulation and an effective strategy to solve the coupled equations. The coupling of ddCOSMO with non variational force fields, including AMOEBA, is also addressed. The MD simulations are feasible, for real life systems, on standard cluster nodes; a scalable parallel implementation allows for further speed up in the context of a newly developed module in Tinker, named Tinker-HP. NVE simulations are stable and long term energy conservation can be achieved. This paper is focused on the methodological developments, on the analysis of the algorithm and on the stability of the simulations; a proof-of-concept application is also presented to attest the possibilities of this newly developed technique. PMID:26516318
Cheel, José; Minceva, Mirjana; Urajová, Petra; Aslam, Rabya; Hrouzek, Pavel; Kopecký, Jiří
2015-10-01
Aeruginosin-865 was isolated from cultivated soil cyanobacteria using a combination of centrifugal partition chromatography (CPC) and gel permeation chromatography. The solubility of Aer-865 in different solvents was evaluated using the conductor-like screening model for real solvents (COSMO-RS). The CPC separation was performed in descending mode with a biphasic solvent system composed of water-n-BuOH-acetic acid (5:4:1, v/v/v). The upper phase was used as a stationary phase, whereas the lower phase was employed as a mobile phase at a flow rate of 10 mL/min. The revolution speed and temperature of the separation column were 1700 rpm and 25 degrees C, respectively. Preparative CPC separation followed by gel permeation chromatography was performed on 50 mg of crude extract yielding Aer-865 (3.5 mg), with a purity over 95% as determined by HPLC. The chemical identity of the isolated compound was confirmed by comparing its spectroscopic data (UV, HRESI-MS, HRESI-MS/MS) with those of an authentic standard and data available in the literature.
Design of transparent conductors and periodic two-dimensional electron gases without doping
NASA Astrophysics Data System (ADS)
Zhang, Xiuwen; Zhang, Lijun; Zunger, Alex; Perkins, John; Materials by Design Team; John D. Perkins Collaboration
The functionality of transparency plus conductivity plays an important role in renewable energy and information technologies, including applications such as solar cells, touch-screen sensors, and flat panel display. However, materials with such seemingly contraindicated properties are difficult to come by. The traditional strategy for designing bulk transparent conductors (TCs) starts from a wide-gap insulator and finds ways to make it conductive by extensive doping. We propose a different strategy for TC design--starting with a metallic conductor and designing transparency by control of intrinsic interband transitions and intraband plasmonic frequency. We identified specific design principles for prototypical intrinsic TC classes and searched computationally for materials that satisfy them. The electron gases in the 3D intrinsic TCs demonstrate intriguing properties, such as periodic 2D electron gas regions with very high carrier density. We will discuss a more extended search of these functionalities, in parallel with stability and growability calculations
Conductors for commercial MRI magnets beyond NbTi: requirements and challenges.
Parizh, Michael; Lvovsky, Yuri; Sumption, Michael
2017-01-01
Magnetic Resonance Imaging (MRI), a powerful medical diagnostic tool, is the largest commercial application of superconductivity. The superconducting magnet is the largest and most expensive component of an MRI system. The magnet configuration is determined by competing requirements including optimized functional performance, patient comfort, ease of siting in a hospital environment, minimum acquisition and lifecycle cost including service. In this paper, we analyze conductor requirements for commercial MRI magnets beyond traditional NbTi conductors, while avoiding links to a particular magnet configuration or design decisions. Potential conductor candidates include MgB 2 , ReBCO and BSCCO options. The analysis shows that no MRI-ready non-NbTi conductor is commercially available at the moment. For some conductors, MRI specifications will be difficult to achieve in principle. For others, cost is a key barrier. In some cases, the prospects for developing an MRI-ready conductor are more favorable, but significant developments are still needed. The key needs include the development of, or significant improvements in: (a) conductors specifically designed for MRI applications, with form-fit-and-function readily integratable into the present MRI magnet technology with minimum modifications. Preferably, similar conductors should be available from multiple vendors; (b) conductors with improved quench characteristics, i.e. the ability to carry significant current without damage while in the resistive state; (c) insulation which is compatible with manufacturing and refrigeration technologies; (d) dramatic increases in production and long-length quality control, including large-volume conductor manufacturing technology. In-situ MgB 2 is, perhaps, the closest to meeting commercial and technical requirements to become suitable for commercial MRI. Conductor technology is an important, but not the only, issue in introduction of HTS / MgB 2 conductor into commercial MRI magnets. These new conductors, even when they meet the above requirements, will likely require numerous modifications and developments in the associated magnet technology.
Conductors for commercial MRI magnets beyond NbTi: requirements and challenges
NASA Astrophysics Data System (ADS)
Parizh, Michael; Lvovsky, Yuri; Sumption, Michael
2017-01-01
Magnetic resonance imaging (MRI), a powerful medical diagnostic tool, is the largest commercial application of superconductivity. The superconducting magnet is the largest and most expensive component of an MRI system. The magnet configuration is determined by competing requirements including optimized functional performance, patient comfort, ease of siting in a hospital environment, minimum acquisition and lifecycle cost including service. In this paper, we analyze conductor requirements for commercial MRI magnets beyond traditional NbTi conductors, while avoiding links to a particular magnet configuration or design decisions. Potential conductor candidates include MgB2, ReBCO and BSCCO options. The analysis shows that no MRI-ready non-NbTi conductor is commercially available at the moment. For some conductors, MRI specifications will be difficult to achieve in principle. For others, cost is a key barrier. In some cases, the prospects for developing an MRI-ready conductor are more favorable, but significant developments are still needed. The key needs include the development of, or significant improvements in: (a) conductors specifically designed for MRI applications, with form-fit-and-function readily integratable into the present MRI magnet technology with minimum modifications. Preferably, similar conductors should be available from multiple vendors; (b) conductors with improved quench characteristics, i.e. the ability to carry significant current without damage while in the resistive state; (c) insulation which is compatible with manufacturing and refrigeration technologies; (d) dramatic increases in production and long-length quality control, including large-volume conductor manufacturing technology. In-situ MgB2 is, perhaps, the closest to meeting commercial and technical requirements to become suitable for commercial MRI. Conductor technology is an important, but not the only, issue in introduction of HTS/MgB2 conductor into commercial MRI magnets. These new conductors, even when they meet the above requirements, will likely require numerous modifications and developments in the associated magnet technology.
Conductors for commercial MRI magnets beyond NbTi: requirements and challenges
Parizh, Michael; Lvovsky, Yuri; Sumption, Michael
2016-01-01
Magnetic Resonance Imaging (MRI), a powerful medical diagnostic tool, is the largest commercial application of superconductivity. The superconducting magnet is the largest and most expensive component of an MRI system. The magnet configuration is determined by competing requirements including optimized functional performance, patient comfort, ease of siting in a hospital environment, minimum acquisition and lifecycle cost including service. In this paper, we analyze conductor requirements for commercial MRI magnets beyond traditional NbTi conductors, while avoiding links to a particular magnet configuration or design decisions. Potential conductor candidates include MgB2, ReBCO and BSCCO options. The analysis shows that no MRI-ready non-NbTi conductor is commercially available at the moment. For some conductors, MRI specifications will be difficult to achieve in principle. For others, cost is a key barrier. In some cases, the prospects for developing an MRI-ready conductor are more favorable, but significant developments are still needed. The key needs include the development of, or significant improvements in: (a) conductors specifically designed for MRI applications, with form-fit-and-function readily integratable into the present MRI magnet technology with minimum modifications. Preferably, similar conductors should be available from multiple vendors; (b) conductors with improved quench characteristics, i.e. the ability to carry significant current without damage while in the resistive state; (c) insulation which is compatible with manufacturing and refrigeration technologies; (d) dramatic increases in production and long-length quality control, including large-volume conductor manufacturing technology. In-situ MgB2 is, perhaps, the closest to meeting commercial and technical requirements to become suitable for commercial MRI. Conductor technology is an important, but not the only, issue in introduction of HTS / MgB2 conductor into commercial MRI magnets. These new conductors, even when they meet the above requirements, will likely require numerous modifications and developments in the associated magnet technology. PMID:28626340
1987-09-01
can be reduced substantially, compared to using numerical methods to model inter - " connect parasitics. Although some accuracy might be lost with...conductor widths and spacings listed in Table 2 1 , have been employed for simulation. In the first set of the simulations, planar dielectric inter ...model, there are no restrictions on the iumber ol diele-iric and conductors. andl the shape of the conductors and the dielectric inter - a.e,, In the
MOD silver metallization for photovoltaics
NASA Technical Reports Server (NTRS)
Vest, G. M.; Vest, R. W.
1984-01-01
The development of flat plate solar arrays is reported. Photovoltaic cells require back side metallization and a collector grid system on the front surface. Metallo-organic decomposition (MOD) silver films can eliminate most of the present problems with silver conductors. The objectives are to: (1) identify and characterize suitable MO compounds; (2) develop generic synthesis procedures for the MO compounds; (3) develop generic fabrication procedures to screen printable MOD silver inks; (4) optimize processing conditions to produce grid patterns and photovoltaic cells; and (5) develop a model which describes the adhesion between the fired silver film and the silicon surface.
Tribologic analyses of a self-mated aluminium contact used for overhead transmission lines
NASA Astrophysics Data System (ADS)
Steier, V. Franco
2017-05-01
The lifetime of aluminium components is often limited to their poor wear resistance. One example for such aluminium applications are overhead transmission lines. The sore points of these lines are the segments where the aluminium conductors are fixed to the line supports. The fixation is commonly realized via aluminium suspension clamps. Here, a superposition of different loads like traction and bending stresses, clamping forces and different types of wear occurs. To investigate the wear behaviour in these peculiar points, tribologic model tests were carried out. Within the tests, overhead conductor wires and aluminium plates, extracted from suspension clamps were reciprocally slid against aluminium plates (cylinder-on-plate test). The COF and a wear related parameter were recorded constantly. Subsequently, the loaded surfaces were analysed using confocal laser and electron scanning microscopy as well as energy dispersive X-ray spectroscopy. The investigation detected the formation of an oxidized tribologic layer between both components. The tribolayer, which mayor part adhered on the suspension clamps, was mostly formed from material removed from the conductor wires.
Electrostatic analogy for symmetron gravity
NASA Astrophysics Data System (ADS)
Ogden, Lillie; Brown, Katherine; Mathur, Harsh; Rovelli, Kevin
2017-12-01
The symmetron model is a scalar-tensor theory of gravity with a screening mechanism that suppresses the effect of the symmetron field at high densities characteristic of the Solar System and laboratory scales but allows it to act with gravitational strength at low density on the cosmological scale. We elucidate the screening mechanism by showing that in the quasistatic Newtonian limit there are precise analogies between symmetron gravity and electrostatics for both strong and weak screening. For strong screening we find that large dense bodies behave in a manner analogous to perfect conductors in electrostatics. Based on this analogy we find that the symmetron field exhibits a lightning rod effect wherein the field gradients are enhanced near the ends of pointed or elongated objects. An ellipsoid placed in a uniform symmetron gradient is shown to experience a torque. By symmetry there is no gravitational torque in this case. Hence this effect unmasks the symmetron and might serve as the basis for future laboratory experiments. The symmetron force between a point mass and a large dense body includes a component corresponding to the interaction of the point mass with its image in the larger body. None of these effects have counterparts in the Newtonian limit of Einstein gravity. We discuss the similarities between symmetron gravity and the chameleon model as well as the differences between the two.
Going full circle: phase-transition thermodynamics of ionic liquids.
Preiss, Ulrich; Verevkin, Sergey P; Koslowski, Thorsten; Krossing, Ingo
2011-05-27
We present the full enthalpic phase transition cycle for ionic liquids (ILs) as examples of non-classical salts. The cycle was closed for the lattice, solvation, dissociation, and vaporization enthalpies of 30 different ILs, relying on as much experimental data as was available. High-quality dissociation enthalpies were calculated at the G3 MP2 level. From the cycle, we could establish, for the first time, the lattice and solvation enthalpies of ILs with imidazolium ions. For vaporization, lattice, and dissociation enthalpies, we also developed new prediction methods in the course of our investigations. Here, as only single-ion values need to be calculated and the tedious optimization of an ion pair can be circumvented, the computational time is short. For the vaporization enthalpy, a very simple approach was found, using a surface term and the calculated enthalpic correction to the total gas-phase energy. For the lattice enthalpy, the most important constituent proved to be the calculated conductor-like screening model (COSMO) solvation enthalpy in the ideal electric conductor. A similar model was developed for the dissociation enthalpy. According to our assessment, the typical error of the lattice enthalpy would be 9.4 kJ mol(-1), which is less than half the deviation we get when using the (optimized) Kapustinskii equation or the recent volume-based thermodynamics (VBT) theory. In contrast, the non-optimized VBT formula gives lattice enthalpies 20 to 140 kJ mol(-1) lower than the ones we assessed in the cycle, because of the insufficient description of dispersive interactions. Our findings show that quantum-chemical calculations can greatly improve the VBT approaches, which were parameterized for simple, inorganic salts with ideally point-shaped charges. In conclusion, we suggest the term "augmented VBT", or "aVBT", to describe this kind of theoretical approach. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Electrostatic potential profiles of molecular conductors
NASA Astrophysics Data System (ADS)
Liang, G. C.; Ghosh, A. W.; Paulsson, M.; Datta, S.
2004-03-01
The electrostatic potential across a short ballistic molecular conductor depends sensitively on the geometry of its environment, and can affect its conduction significantly by influencing its energy levels and wave functions. We illustrate some of the issues involved by evaluating the potential profiles for a conducting gold wire and an aromatic phenyl dithiol molecule in various geometries. The potential profile is obtained by solving Poisson’s equation with boundary conditions set by the contact electrochemical potentials and coupling the result self-consistently with a nonequilibrium Green’s function formulation of transport. The overall shape of the potential profile (ramp versus flat) depends on the feasibility of transverse screening of electric fields. Accordingly, the screening is better for a thick wire, a multiwalled nanotube, or a close-packed self-assembled monolayer, in comparison to a thin wire, a single-walled nanotube, or an isolated molecular conductor. The electrostatic potential further governs the alignment or misalignment of intramolecular levels, which can strongly influence the molecular current voltage (I V) characteristic. An external gate voltage can modify the overall potential profile, changing the I V characteristic from a resonant conducting to a saturating one. The degree of saturation and gate modulation depends on the availability of metal-induced-gap states and on the electrostatic gate control parameter set by the ratio of the gate oxide thickness to the channel length.
NASA Astrophysics Data System (ADS)
Hilton, D. K.; Gavrilin, A. V.; Trociewitz, U. P.
2015-07-01
Applications of (RE = Y, Gd)BCO coated conductors for the generation of high magnetic fields are increasing sharply, this while (RE)BCO coated conductors themselves are evolving rapidly. This article describes and demonstrates recently developed and applied mathematical models that systematically and comprehensively characterize the transport critical current angular dependence of a batch of (RE)BCO coated conductor in high magnetic fields at fixed temperatures with an uncertainty of 10% or better. The model development was based on analysis of experimental data sets from various published sources and coated conductors with different microstructures. These derivations directly are applicable to the accurate prediction of the performance in high magnetic fields of coils wound with (RE)BCO coated conductors. In particular, a nonlinear fit is discussed in this article of transport critical current at T = 4.2 K versus field and angle data. This fit was used to estimate the hysteresis losses of (RE)BCO coated conductors in high magnetic fields, and to design the inserts wound with such conductors of the all-superconducting 32 T magnet being constructed at the NHMFL. A series of such fits, recently developed at several fixed temperatures, continues to be used to simulate the quench behavior of that magnet.
Professional Orchestral Conductors' Use of Selected Teaching Behaviors in Rehearsal
ERIC Educational Resources Information Center
Whitaker, Jennifer A.
2017-01-01
This descriptive study examined professional conductors' use of rehearsal time in sequential pattern components, discussing task presentation targets, and using verbal imagery and modeling techniques. Commercially available videos of 15 professional conductors rehearsing prominent orchestras were scripted, coded, and timed for selected teaching…
Cryogenic Quenching Process for Electronic Part Screening
NASA Technical Reports Server (NTRS)
Sheldon, Douglas J.; Cressler, John
2011-01-01
The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.
Hierarchical Material Properties in Finite Element Analysis: The Oilfield Infrastructure Problem.
NASA Astrophysics Data System (ADS)
Weiss, C. J.; Wilson, G. A.
2017-12-01
Geophysical simulation of low-frequency electromagnetic signals within built environments such as urban centers and industrial landscapes facilities is a challenging computational problem because strong conductors (e.g., pipes, fences, rail lines, rebar, etc.) are not only highly conductive and/or magnetic relative to the surrounding geology, but they are very small in one or more of their physical length coordinates. Realistic modeling of such structures as idealized conductors has long been the standard approach; however this strategy carries with it computational burdens such as cumbersome implementation of internal boundary conditions, and limited flexibility for accommodating realistic geometries. Another standard approach is "brute force" discretization (often coupled with an equivalent medium model) whereby 100's of millions of voxels are used to represent these strong conductors, but at the cost of extreme computation times (and mesh design) for a simulation result when possible. To minimize these burdens, a new finite element scheme (Weiss, Geophysics, 2017) has been developed in which the material properties reside on a hierarchy of geometric simplicies (i.e., edges, facets and volumes) within an unstructured tetrahedral mesh. This allows thin sheet—like structures, such as subsurface fractures, to be economically represented by a connected set of triangular facets, for example, that freely conform to arbitrary "real world" geometries. The same holds thin pipe/wire-like structures, such as casings or pipelines. The hierarchical finite element scheme has been applied to problems in electro- and magnetostatics for oilfield problems where the elevated, but finite, conductivity and permeability of the steel-cased oil wells must be properly accounted for, yielding results that are otherwise unobtainable, with run times as low as a few 10s of seconds. Extension of the hierarchical finite element concept to broadband electromagnetics is presently underway, as are its implications for geophysical inversion.
Design-Based Research as an Informal Learning Model for Choral Conductors
ERIC Educational Resources Information Center
Cooper, Naomi
2017-01-01
The number of community choirs continues to grow, and literature endorsing the benefits of choral singing for physical, mental and emotional health and well-being is rapidly expanding, meaning that the professional development of community choral conductors is in the public interest. However, research on choral conductor education remains limited.…
Metalizing Solar Cells by Selective Electroplating
NASA Technical Reports Server (NTRS)
Dutta, S.; Palaschak, P. A.
1986-01-01
Contact patterns traced by laser scanning. Conductor paths deposited on silicon solar-cell wafers by laser irradiation followed by electroplating. Laser-assisted metalization technique offers better resolution and lower contact resistance than does conventional metalization by screen printing. At the same time, less expensive than metalization with masks and photolithography.
NASA Astrophysics Data System (ADS)
Shinde, Manish; Pawar, Amol; Karmakar, Soumen; Seth, Tanay; Raut, Varsha; Rane, Sunit; Bhoraskar, Sudha; Amalnerkar, Dinesh
2009-11-01
Uncapped silver nanoparticles were synthesized by DC arc thermal plasma technique. The synthesized nanoparticles were structurally cubic and showed wide particle size variation (between 20-150 nm). Thick film paste formulated from such uncapped silver nanoparticles was screen-printed on alumina substrates and the resultant `green' films were fired at different firing temperatures. The films fired at 600 °C revealed better microstructure properties and also yielded the lowest value of sheet resistance in comparison to those corresponding to conventional peak firing temperature of 850 °C. Our findings directly support the role of silver nanoparticles in substantially depressing the operative peak firing temperature involved in traditional conductor thick films technology.
NASA Astrophysics Data System (ADS)
Mitchell, N.
2007-01-01
Nb3Sn cable in conduit-type conductors were expected to provide an efficient way of achieving large conductor currents at high field (up to 13 T) combined with good stability to electromagnetic disturbances due to the extensive helium contact area with the strands. Although ITER model coils successfully reached their design performance (Kato et al 2001 Fusion Eng. Des. 56/57 59-70), initial indications (Mitchell 2003 Fusion Eng. Des. 66-68 971-94) that there were unexplained performance shortfalls have been confirmed. Recent conductor tests (Pasztor et al 2004 IEEE Trans. Appl. Supercond. 14 1527-30) and modelling work (Mitchell 2005 Supercond. Sci. Technol. 18 396-404) suggest that the shortfalls are due to a combination of strand bending and filament fracture under the transverse magnetic loads. Using the new model, the extensive database from the ITER CS insert coil has been reassessed. A parametric fit based on a loss of filament area and n (the exponent of the power-law fit to the electric field) combined with a more rigorous consideration of the conductor field gradient has enabled the coil behaviour to be explained much more consistently than in earlier assessments, now fitting the Nb3Sn strain scaling laws when used with measurements of the conductor operating strain, including conditions when the insert coil current (and hence operating strain) were reversed. The coil superconducting performance also shows a fatigue-type behaviour consistent with recent measurements on conductor samples (Martovetsky et al 2005 IEEE Trans. Appl. Supercond. 15 1367-70). The ITER conductor design has already been modified compared to the CS insert, to increase the margin and provide increased resistance to the degradation, by using a steel jacket to provide thermal pre-compression to reduce tensile strain levels, reducing the void fraction from 36% to 33% and increasing the non-copper material by 25%. Test results are not yet available for the new design and performance predictions at present rely on models with limited verification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuechler, Erich R.; Department of Chemistry, University of Minnesota, Minneapolis, Minnesota 55455-0431; Giese, Timothy J.
To better represent the solvation effects observed along reaction pathways, and of ionic species in general, a charge-dependent variable-radii smooth conductor-like screening model (VR-SCOSMO) is developed. This model is implemented and parameterized with a third order density-functional tight binding quantum model, DFTB3/3OB-OPhyd, a quantum method which was developed for organic and biological compounds, utilizing a specific parameterization for phosphate hydrolysis reactions. Unlike most other applications with the DFTB3/3OB model, an auxiliary set of atomic multipoles is constructed from the underlying DFTB3 density matrix which is used to interact the solute with the solvent response surface. The resulting method is variational,more » produces smooth energies, and has analytic gradients. As a baseline, a conventional SCOSMO model with fixed radii is also parameterized. The SCOSMO and VR-SCOSMO models shown have comparable accuracy in reproducing neutral-molecule absolute solvation free energies; however, the VR-SCOSMO model is shown to reduce the mean unsigned errors (MUEs) of ionic compounds by half (about 2-3 kcal/mol). The VR-SCOSMO model presents similar accuracy as a charge-dependent Poisson-Boltzmann model introduced by Hou et al. [J. Chem. Theory Comput. 6, 2303 (2010)]. VR-SCOSMO is then used to examine the hydrolysis of trimethylphosphate and seven other phosphoryl transesterification reactions with different leaving groups. Two-dimensional energy landscapes are constructed for these reactions and calculated barriers are compared to those obtained from ab initio polarizable continuum calculations and experiment. Results of the VR-SCOSMO model are in good agreement in both cases, capturing the rate-limiting reaction barrier and the nature of the transition state.« less
Analytical investigation in bending characteristic of twisted stacked-tape cable conductor
NASA Astrophysics Data System (ADS)
Takayasu, Makoto; Chiesa, Luisa
2015-12-01
An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.
Lorvidhaya, Peem; Mendoza, Ivan; Sehli, Sharmila; Atalay, Michael K; Kim, Michael H
2013-11-01
Lead insulation defects with externalization of the conductors exist in Riata defibrillator leads. Cinefluoroscopy is currently the gold standard to detect such defects. Prospective evaluation of alternative screening options such as chest radiography (CXR), which has been recommended by the FDA, is not well described. Patients with Riata leads underwent cinefluoroscopy, CXR, and device interrogation. Leads were classified as abnormal (clear cable separation), borderline, or normal by independent evaluation of cinefluoroscopy and CXR. CXR evaluation was done in two ways as follows: (1) routine CXR read by daily staff radiologists for lead screening and (2) CXR evaluation by a radiologist educated about the lead defect. One hundred two patients were evaluated at our institution. Cinefluoroscopy showed externalized conductors in 33 patients (32 %). Twenty-five of 33 patients (76 %) who had abnormal cinefluoroscopic findings had abnormal CXR findings on blinded review by the educated radiologist. All 25 patients with abnormal CXR had abnormal findings on cinefluoroscopy. Daily staff radiologists without direct education other than prompts for lead screening detected CXR abnormalities in only 8 out of 102 (8 %) cases. Cinefluoroscopy appears to be more sensitive than CXR for the detection of Riata cable extrusion. Interpretation of CXR by a radiologist with education in lead defects correlates highly with cinefluoroscopy with very high specificity. Depending on available resources for screening, CXR may be a reasonable alternative to cinefluoroscopy. Multidisciplinary collaboration across specialties (radiology and electrophysiology) can lead to improved diagnostic capability and thus the potential for enhanced quality of care.
GEOquery: a bridge between the Gene Expression Omnibus (GEO) and BioConductor.
Davis, Sean; Meltzer, Paul S
2007-07-15
Microarray technology has become a standard molecular biology tool. Experimental data have been generated on a huge number of organisms, tissue types, treatment conditions and disease states. The Gene Expression Omnibus (Barrett et al., 2005), developed by the National Center for Bioinformatics (NCBI) at the National Institutes of Health is a repository of nearly 140,000 gene expression experiments. The BioConductor project (Gentleman et al., 2004) is an open-source and open-development software project built in the R statistical programming environment (R Development core Team, 2005) for the analysis and comprehension of genomic data. The tools contained in the BioConductor project represent many state-of-the-art methods for the analysis of microarray and genomics data. We have developed a software tool that allows access to the wealth of information within GEO directly from BioConductor, eliminating many the formatting and parsing problems that have made such analyses labor-intensive in the past. The software, called GEOquery, effectively establishes a bridge between GEO and BioConductor. Easy access to GEO data from BioConductor will likely lead to new analyses of GEO data using novel and rigorous statistical and bioinformatic tools. Facilitating analyses and meta-analyses of microarray data will increase the efficiency with which biologically important conclusions can be drawn from published genomic data. GEOquery is available as part of the BioConductor project.
Schröder, Bernd; Freire, Mara G; Varanda, Fatima R; Marrucho, Isabel M; Santos, Luís M N B F; Coutinho, João A P
2011-07-01
The aqueous solubility of hexafluorobenzene has been determined, at 298.15K, using a shake-flask method with a spectrophotometric quantification technique. Furthermore, the solubility of hexafluorobenzene in saline aqueous solutions, at distinct salt concentrations, has been measured. Both salting-in and salting-out effects were observed and found to be dependent on the nature of the cationic/anionic composition of the salt. COSMO-RS, the Conductor-like Screening Model for Real Solvents, has been used to predict the corresponding aqueous solubilities at conditions similar to those used experimentally. The prediction results showed that the COSMO-RS approach is suitable for the prediction of salting-in/-out effects. The salting-in/-out phenomena have been rationalized with the support of COSMO-RS σ-profiles. The prediction potential of COSMO-RS regarding aqueous solubilities and octanol-water partition coefficients has been compared with typically used QSPR-based methods. Up to now, the absence of accurate solubility data for hexafluorobenzene hampered the calculation of the respective partition coefficients. Combining available accurate vapor pressure data with the experimentally determined water solubility, a novel air-water partition coefficient has been derived. Copyright © 2011 Elsevier Ltd. All rights reserved.
Design principles for solid-state lithium superionic conductors.
Wang, Yan; Richards, William Davidson; Ong, Shyue Ping; Miara, Lincoln J; Kim, Jae Chul; Mo, Yifei; Ceder, Gerbrand
2015-10-01
Lithium solid electrolytes can potentially address two key limitations of the organic electrolytes used in today's lithium-ion batteries, namely, their flammability and limited electrochemical stability. However, achieving a Li(+) conductivity in the solid state comparable to existing liquid electrolytes (>1 mS cm(-1)) is particularly challenging. In this work, we reveal a fundamental relationship between anion packing and ionic transport in fast Li-conducting materials and expose the desirable structural attributes of good Li-ion conductors. We find that an underlying body-centred cubic-like anion framework, which allows direct Li hops between adjacent tetrahedral sites, is most desirable for achieving high ionic conductivity, and that indeed this anion arrangement is present in several known fast Li-conducting materials and other fast ion conductors. These findings provide important insight towards the understanding of ionic transport in Li-ion conductors and serve as design principles for future discovery and design of improved electrolytes for Li-ion batteries.
Jalem, Randy; Kanamori, Kenta; Takeuchi, Ichiro; Nakayama, Masanobu; Yamasaki, Hisatsugu; Saito, Toshiya
2018-04-11
Safe and robust batteries are urgently requested today for power sources of electric vehicles. Thus, a growing interest has been noted for fabricating those with solid electrolytes. Materials search by density functional theory (DFT) methods offers great promise for finding new solid electrolytes but the evaluation is known to be computationally expensive, particularly on ion migration property. In this work, we proposed a Bayesian-optimization-driven DFT-based approach to efficiently screen for compounds with low ion migration energies ([Formula: see text]. We demonstrated this on 318 tavorite-type Li- and Na-containing compounds. We found that the scheme only requires ~30% of the total DFT-[Formula: see text] evaluations on the average to recover the optimal compound ~90% of the time. Its recovery performance for desired compounds in the tavorite search space is ~2× more than random search (i.e., for [Formula: see text] < 0.3 eV). Our approach offers a promising way for addressing computational bottlenecks in large-scale material screening for fast ionic conductors.
Theoretical study of chain transfer to solvent reactions of alkyl acrylates.
Moghadam, Nazanin; Srinivasan, Sriraj; Grady, Michael C; Rappe, Andrew M; Soroush, Masoud
2014-07-24
This computational and theoretical study deals with chain transfer to solvent (CTS) reactions of methyl acrylate (MA), ethyl acrylate (EA), and n-butyl acrylate (n-BA) self-initiated homopolymerization in solvents such as butanol (polar, protic), methyl ethyl ketone (MEK) (polar, aprotic), and p-xylene (nonpolar). The results indicate that abstraction of a hydrogen atom from the methylene group next to the oxygen atom in n-butanol, from the methylene group in MEK, and from a methyl group in p-xylene by a live polymer chain are the most likely mechanisms of CTS reactions in MA, EA, and n-BA. Energy barriers and molecular geometries of reactants, products, and transition states are predicted. The sensitivity of the predictions to three hybrid functionals (B3LYP, X3LYP, and M06-2X) and three different basis sets (6-31G(d,p), 6-311G(d), and 6-311G(d,p)) is investigated. Among n-butanol, sec-butanol, and tert-butanol, tert-butanol has the highest CTS energy barrier and the lowest rate constant. Although the application of the conductor-like screening model (COSMO) does not affect the predicted CTS kinetic parameter values, the application of the polarizable continuum model (PCM) results in higher CTS energy barriers. This increase in the predicted CTS energy barriers is larger for butanol and MEK than for p-xylene. The higher rate constants of chain transfer to n-butanol reactions compared to those of chain transfer to MEK and p-xylene reactions suggest the higher CTS reactivity of n-butanol.
Mobility propagation and dynamic facilitation in superionic conductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Annamareddy, Ajay, E-mail: vkannama@ncsu.edu; Eapen, Jacob, E-mail: jacob.eapen@ncsu.edu
2015-11-21
In an earlier work [V. A. Annamareddy et al., Phys. Rev. E 89, 010301(R) (2014)], we showed the manifestation of dynamical heterogeneity (DH)—the presence of clustered mobile and immobile regions—in UO{sub 2}, a model type II superionic conductor. In the current work, we demonstrate the mechanism of dynamic facilitation (DF) in two superionic conductors (CaF{sub 2} and UO{sub 2}) using atomistic simulations. Using the mobility transfer function, DF is shown to vary non-monotonically with temperature with the intensity of DF peaking at temperatures close to the superionic transition temperature (T{sub λ}). Both the metrics quantifying DH and DF show remarkablemore » correspondence implying that DF, in the framework of kinematically constrained models, underpins the heterogeneous dynamics in type II superionic conductors.« less
Room Temperature Ammonia Gas Sensing Using Mixed Conductor based TEMPOS Structures.
Saroch, Mamta; Srivastava, Sunita; Fink, Dietmar; Chandra, Amita
2008-10-14
The current/voltage characteristics of mixed (ion+electron) conductor-based 'TEMPOS' (Tunable Electronic Material with Pores in Oxide on Silicon) structures are reported. TEMPOS are novel electronic MOS-like structures having etched swift heavy ion tracks (i.e., nanopores) in the dielectric layer filled with some conducting material. The three contacts (two on top and one on the bottom), which resemble the classical bipolar or field effect transistor arrangements are, in principle, interchangeable when the overall electrical resistance along the tracks and on the surface are similar. Consequently, three configurations are obtained by interchanging the top contacts with the base contact in electronic circuits. The current/voltage characteristics show a diode like behaviour. Impedance measurements have been made for TEMPOS structures with tracks filled with ion conductors and also mixed conductors to study the ammonia sensing behaviour. The impedance has been found to be a function of frequency and magnitude of the applied signal and concentration of the ammonia solution. This is attributed to the large number of charge carriers (here protons) available for conduction on exposure to ammonia and also to the large surface to volume ratio of the polymer composites embedded in the ion tracks. The measurement of both, the real and imaginary parts of impedance allows one to enhance the detection sensitivity greatly.
Room Temperature Ammonia Gas Sensing Using Mixed Conductor based TEMPOS Structures
Saroch, Mamta; Srivastava, Sunita; Fink, Dietmar; Chandra, Amita
2008-01-01
The current/voltage characteristics of mixed (ion+electron) conductor-based ‘TEMPOS’ (Tunable Electronic Material with Pores in Oxide on Silicon) structures̵ are reported. TEMPOS are novel electronic MOS-like structures having etched swift heavy ion tracks (i.e., nanopores) in the dielectric layer filled with some conducting material. The three contacts (two on top and one on the bottom), which resemble the classical bipolar or field effect transistor arrangements are, in principle, interchangeable when the overall electrical resistance along the tracks and on the surface are similar. Consequently, three configurations are obtained by interchanging the top contacts with the base contact in electronic circuits. The current/voltage characteristics show a diode like behaviour. Impedance measurements have been made for TEMPOS structures with tracks filled with ion conductors and also mixed conductors to study the ammonia sensing behaviour. The impedance has been found to be a function of frequency and magnitude of the applied signal and concentration of the ammonia solution. This is attributed to the large number of charge carriers (here protons) available for conduction on exposure to ammonia and also to the large surface to volume ratio of the polymer composites embedded in the ion tracks. The measurement of both, the real and imaginary parts of impedance allows one to enhance the detection sensitivity greatly. PMID:27873874
NASA Astrophysics Data System (ADS)
Li, Xuebao; Cui, Xiang; Lu, Tiebing; Ma, Wenzuo; Bian, Xingming; Wang, Donglai; Hiziroglu, Huseyin
2016-03-01
The corona-generated audible noise (AN) has become one of decisive factors in the design of high voltage direct current (HVDC) transmission lines. The AN from transmission lines can be attributed to sound pressure pulses which are generated by the multiple corona sources formed on the conductor, i.e., transmission lines. In this paper, a detailed time-domain characteristics of the sound pressure pulses, which are generated by the DC corona discharges formed over the surfaces of a stranded conductors, are investigated systematically in a laboratory settings using a corona cage structure. The amplitude of sound pressure pulse and its time intervals are extracted by observing a direct correlation between corona current pulses and corona-generated sound pressure pulses. Based on the statistical characteristics, a stochastic model is presented for simulating the sound pressure pulses due to DC corona discharges occurring on conductors. The proposed stochastic model is validated by comparing the calculated and measured A-weighted sound pressure level (SPL). The proposed model is then used to analyze the influence of the pulse amplitudes and pulse rate on the SPL. Furthermore, a mathematical relationship is found between the SPL and conductor diameter, electric field, and radial distance.
Microstructure of a base metal thick film system. [Glass frit with base metal oxide addition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mentley, D.E.
1976-06-01
A base metal thick film conductor system using glass frits with base metal oxide additions was investigated as metallization for hybrid microcircuits. Application of previous work on wetting and chemical bonding was made to this system. The observation of changes in the properties of the thick film was made by photomicrographs of screened samples and sheet resistivity measurements. In addition to the chemical and wetting properties, the effect of glass frit particle size on conductivity was also analyzed. The base metal oxide addition was found to produce a more consistent thick film conductor at low volume percentages of metal bymore » inhibiting the formation of low melting redox reaction products.« less
Aeolian vibration control of overhead electrical transmission line conductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sireteanu, T.; Migdalovici, M.; Videa, E.
The paper presents a mathematical model and an analytical procedure to control the wind induced vibration of a single conductor such that the dynamic strain about the suspension clamp is kept within the imposed safety limits. The method is based on the energy balance principle which takes into account the wind energy input, the energy dissipated by the conductor self-damping properties and by the Stockbridge dampers which are frequently used for the aeolian vibration control. The damping characteristics of the Stockbridge dampers are expressed in terms of their mechanical impedance determined experimentally on a vibration exciter. The method can bemore » used to establish whether or not it is necessary to equip the conductor by Stockbridge dampers, which type of damper is more suitable for a given conductor, span length and EDS (every day stress), the necessary number of dampers as well as their optimum spacing on the conductor.« less
Screen-Cage Ion Plating Of Silver On Polycrystalline Alumina
NASA Technical Reports Server (NTRS)
Spalvins, Talivaldis; Sliney, Harold E.; Deadmore, Daniel L.
1995-01-01
Screen-cage ion plating (SCIP) cost-effective technique offering high throwing power for deposition of adherent metal films on ceramic substrates. Applies silver films to complexly shaped substrates of polycrystalline alumina. Silver adheres tenaciously and reduces friction. SCIP holds promise for applying lubricating soft metallic films to high-temperature ceramic components of advanced combustion engines. Other potential uses include coating substrates with metal for protection against corrosion, depositing electrical conductors on dielectric substrates, making optically reflective or electrically or thermally conductive surface layers, and applying decorative metal coats to ceramic trophies or sculptures.
NASA Astrophysics Data System (ADS)
Matsuda, Y.; Kakutani, K.; Nonomura, T.; Kimbara, J.; Osamura, K.; Kusakar, S.; Toyoda, H.
2015-10-01
An electric field screen can be used to keep mosquitoes out of houses with open windows. In this study, doubly charged dipolar electric field screens (DD-screens) were used to capture mosquitoes entering through a window. The screen had two components: three layers of insulated conductor iron wires (ICWs) in parallel arrays and two electrostatic direct current (DC) voltage generators that supplied negative or positive voltages to the ICWs. Within each layer, the ICWs were parallel at 5-mm intervals, and connected to each other and to a negative or positive voltage generator. The negatively and positively charged ICWs are represented as ICW(-) and ICW(+), respectively. The screen consisted of one ICW(+) layer with an ICW(-) layer on either side. The Asian tiger mosquito (Aedes albopictus) and house mosquito (Culex pipiens) were used as models of vectors carrying viral pathogens. Adult mosquitoes were blown into the space between the ICWs by sending compressed air through the tip of an insect aspirator to determine the voltage range that captured all of the test insects. Wind speed was measured at the surface of the ICW using a sensitive anemometer. The result showed that at ≥ 1.2 kV, the force was strong enough that the ICWs captured all of the mosquitoes, despite a wind speed of 7 m/s. Therefore, the DD-screen could serve as a physical barrier to prevent noxious mosquitoes from entering houses with good air penetration.
ERIC Educational Resources Information Center
Freer, Patrick K.
2007-01-01
Because there are hundreds, perhaps thousands, of honor choir events each year across the United States, most choir directors will likely be invited to conduct an honor choir at one point or another. Additionally, many conductors will work with honor choirs at the city, municipal, and county levels. Still others will work with ensembles from…
Surface property detection apparatus and method
Martens, J.S.; Ginley, D.S.; Hietala, V.M.; Sorensen, N.R.
1995-08-08
Apparatus and method for detecting, determining, and imaging surface resistance corrosion, thin film growth, and oxide formation on the surface of conductors or other electrical surface modification. The invention comprises a modified confocal resonator structure with the sample remote from the radiating mirror. Surface resistance is determined by analyzing and imaging reflected microwaves; imaging reveals anomalies due to surface impurities, non-stoichiometry, and the like, in the surface of the superconductor, conductor, dielectric, or semiconductor. 4 figs.
A novel eddy current damper: theory and experiment
NASA Astrophysics Data System (ADS)
Ebrahimi, Babak; Khamesee, Mir Behrad; Golnaraghi, Farid
2009-04-01
A novel eddy current damper is developed and its damping characteristics are studied analytically and experimentally. The proposed eddy current damper consists of a conductor as an outer tube, and an array of axially magnetized ring-shaped permanent magnets separated by iron pole pieces as a mover. The relative movement of the magnets and the conductor causes the conductor to undergo motional eddy currents. Since the eddy currents produce a repulsive force that is proportional to the velocity of the conductor, the moving magnet and the conductor behave as a viscous damper. The eddy current generation causes the vibration to dissipate through the Joule heating generated in the conductor part. An accurate, analytical model of the system is obtained by applying electromagnetic theory to estimate the damping properties of the proposed eddy current damper. A prototype eddy current damper is fabricated, and experiments are carried out to verify the accuracy of the theoretical model. The experimental test bed consists of a one-degree-of-freedom vibration isolation system and is used for the frequency and transient time response analysis of the system. The eddy current damper model has a 0.1 m s-2 (4.8%) RMS error in the estimation of the mass acceleration. A damping coefficient as high as 53 Ns m-1 is achievable with the fabricated prototype. This novel eddy current damper is an oil-free, inexpensive damper that is applicable in various vibration isolation systems such as precision machinery, micro-mechanical suspension systems and structure vibration isolation.
A simple node and conductor data generator for SINDA
NASA Technical Reports Server (NTRS)
Gottula, Ronald R.
1992-01-01
This paper presents a simple, automated method to generate NODE and CONDUCTOR DATA for thermal match modes. The method uses personal computer spreadsheets to create SINDA inputs. It was developed in order to make SINDA modeling less time consuming and serves as an alternative to graphical methods. Anyone having some experience using a personal computer can easily implement this process. The user develops spreadsheets to automatically calculate capacitances and conductances based on material properties and dimensional data. The necessary node and conductor information is then taken from the spreadsheets and automatically arranged into the proper format, ready for insertion directly into the SINDA model. This technique provides a number of benefits to the SINDA user such as a reduction in the number of hand calculations, and an ability to very quickly generate a parametric set of NODE and CONDUCTOR DATA blocks. It also provides advantages over graphical thermal modeling systems by retaining the analyst's complete visibility into the thermal network, and by permitting user comments anywhere within the DATA blocks.
Magnetic flux-load current interactions in ferrous conductors
NASA Astrophysics Data System (ADS)
Cannell, Michael J.; McConnell, Richard A.
1992-06-01
A modeling technique has been developed to account for interactions between load current and magnetic flux in an iron conductor. Such a conductor would be used in the active region of a normally conducting homopolar machine. This approach has been experimentally verified and its application to a real machine demonstrated. Additionally, measurements of the resistivity of steel under the combined effects of magnetic field and current have been conducted.
A discrete method for modal analysis of overhead line conductor bundles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Migdalovici, M.A.; Sireteanu, T.D.; Albrecht, A.A.
The paper presents a mathematical model and a semi-analytical procedure to calculate the vibration modes and eigenfrequencies of single or bundled conductors with spacers which are needed for evaluation of the wind induced vibration of conductors and for optimization of spacer-dampers placement. The method consists in decomposition of conductors in modules and the expansion by polynomial series of unknown displacements on each module. A complete system of polynomials are deduced for this by Legendre polynomials. Each module is considered either boundary conditions at the extremity of the module or the continuity conditions between the modules and also a number ofmore » projections of module equilibrium equation on the polynomials from the expansion series of unknown displacement. The global system of the eigenmodes and eigenfrequencies is of the matrix form: A X + {omega}{sup 2} M X = 0. The theoretical considerations are exemplified on one conductor and on bundle of two conductors with spacers. From this, a method for forced vibration calculus of a single or bundled conductors is also presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morozovska, Anna N.; Morozovsky, Nicholas V.; Eliseev, Eugene A.
We performed self-consistent modelling of nonlinear electrotransport and electromechanical response of thin films of mixed ionic-electronic conductors (MIEC) allowing for steric effects of mobile charged defects (ions, protons, or vacancies), electron degeneration, and Vegard stresses. We establish correlations between the features of the nonlinear space-charge dynamics, current-voltage, and bending-voltage curves for different types of the film electrodes. A pronounced ferroelectric-like hysteresis of the bending-voltage loops and current maxima on the double hysteresis current-voltage loops appear for the electron-transport electrodes. The double hysteresis loop with pronounced humps indicates a memristor-type resistive switching. The switching occurs due to the strong nonlinear couplingmore » between the electronic and ionic subsystems. A sharp meta-stable maximum of the electron density appears near one open electrode and moves to another one during the periodic change of applied voltage. Our results can explain the nonlinear nature and correlation of electrical and mechanical memory effects in thin MIEC films. The analytical expression proving that the electrically induced bending of MIEC films can be detected by interferometric methods is derived.« less
NASA Astrophysics Data System (ADS)
Jing, Ze; Yong, Huadong; Zhou, Youhe
2012-08-01
In this paper, a theoretical model is proposed to analyze the transverse normal stress and interfacial shearing stress induced by the electromagnetic force in the superconducting coated conductor. The plane strain approach is used and a singular integral equation is derived. By assuming that the critical current density is magnetic field independent and the superconducting film is infinitely thin, the interfacial shearing stress and normal stress in the film are evaluated for the coated conductor during the increasing and decreasing in the transport current, respectively. The calculation results are discussed and compared for the conductor with different substrate and geometry. The results indicate that the coated conductor with stiffer substrate and larger width experiences larger interfacial shearing stress and less normal stress in the film.
Customizing G Protein-coupled receptor models for structure-based virtual screening.
de Graaf, Chris; Rognan, Didier
2009-01-01
This review will focus on the construction, refinement, and validation of G Protein-coupled receptor models for the purpose of structure-based virtual screening. Practical tips and tricks derived from concrete modeling and virtual screening exercises to overcome the problems and pitfalls associated with the different steps of the receptor modeling workflow will be presented. These examples will not only include rhodopsin-like (class A), but also secretine-like (class B), and glutamate-like (class C) receptors. In addition, the review will present a careful comparative analysis of current crystal structures and their implication on homology modeling. The following themes will be discussed: i) the use of experimental anchors in guiding the modeling procedure; ii) amino acid sequence alignments; iii) ligand binding mode accommodation and binding cavity expansion; iv) proline-induced kinks in transmembrane helices; v) binding mode prediction and virtual screening by receptor-ligand interaction fingerprint scoring; vi) extracellular loop modeling; vii) virtual filtering schemes. Finally, an overview of several successful structure-based screening shows that receptor models, despite structural inaccuracies, can be efficiently used to find novel ligands.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xuebao, E-mail: lxb08357x@ncepu.edu.cn; Cui, Xiang, E-mail: x.cui@ncepu.edu.cn; Ma, Wenzuo
The corona-generated audible noise (AN) has become one of decisive factors in the design of high voltage direct current (HVDC) transmission lines. The AN from transmission lines can be attributed to sound pressure pulses which are generated by the multiple corona sources formed on the conductor, i.e., transmission lines. In this paper, a detailed time-domain characteristics of the sound pressure pulses, which are generated by the DC corona discharges formed over the surfaces of a stranded conductors, are investigated systematically in a laboratory settings using a corona cage structure. The amplitude of sound pressure pulse and its time intervals aremore » extracted by observing a direct correlation between corona current pulses and corona-generated sound pressure pulses. Based on the statistical characteristics, a stochastic model is presented for simulating the sound pressure pulses due to DC corona discharges occurring on conductors. The proposed stochastic model is validated by comparing the calculated and measured A-weighted sound pressure level (SPL). The proposed model is then used to analyze the influence of the pulse amplitudes and pulse rate on the SPL. Furthermore, a mathematical relationship is found between the SPL and conductor diameter, electric field, and radial distance.« less
Complexation and molecular modeling studies of europium(III)-gallic acid-amino acid complexes.
Taha, Mohamed; Khan, Imran; Coutinho, João A P
2016-04-01
With many metal-based drugs extensively used today in the treatment of cancer, attention has focused on the development of new coordination compounds with antitumor activity with europium(III) complexes recently introduced as novel anticancer drugs. The aim of this work is to design new Eu(III) complexes with gallic acid, an antioxida'nt phenolic compound. Gallic acid was chosen because it shows anticancer activity without harming health cells. As antioxidant, it helps to protect human cells against oxidative damage that implicated in DNA damage, cancer, and accelerated cell aging. In this work, the formation of binary and ternary complexes of Eu(III) with gallic acid, primary ligand, and amino acids alanine, leucine, isoleucine, and tryptophan was studied by glass electrode potentiometry in aqueous solution containing 0.1M NaNO3 at (298.2 ± 0.1) K. Their overall stability constants were evaluated and the concentration distributions of the complex species in solution were calculated. The protonation constants of gallic acid and amino acids were also determined at our experimental conditions and compared with those predicted by using conductor-like screening model for realistic solvation (COSMO-RS) model. The geometries of Eu(III)-gallic acid complexes were characterized by the density functional theory (DFT). The spectroscopic UV-visible and photoluminescence measurements are carried out to confirm the formation of Eu(III)-gallic acid complexes in aqueous solutions. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bremner, Paul G.; Vazquez, Gabriel; Christiano, Daniel J.; Trout, Dawn H.
2016-01-01
Prediction of the maximum expected electromagnetic pick-up of conductors inside a realistic shielding enclosure is an important canonical problem for system-level EMC design of space craft, launch vehicles, aircraft and automobiles. This paper introduces a simple statistical power balance model for prediction of the maximum expected current in a wire conductor inside an aperture enclosure. It calculates both the statistical mean and variance of the immission from the physical design parameters of the problem. Familiar probability density functions can then be used to predict the maximum expected immission for deign purposes. The statistical power balance model requires minimal EMC design information and solves orders of magnitude faster than existing numerical models, making it ultimately viable for scaled-up, full system-level modeling. Both experimental test results and full wave simulation results are used to validate the foundational model.
Non-noble metal based metallization systems
NASA Technical Reports Server (NTRS)
Garcia, A., III
1983-01-01
The results of efforts to produce a nonsilver metallization system for silicon photovoltaic cells are given. The system uses a metallization system based on molybdenum, tin, and titanium hydride. The initial work in this system was done using the MIDFILM process. The MIDFILM process attains a line resolution comparable to photoresist methods with a process related to screen printing. The surface to be processed is first coated with a thin layer of photopolymer material. Upon exposure to ultraviolet light through a suitable mask, the polymer in the non-pattern area crosslinks and becomes hard. The unexposed pattern areas remain tacky. The conductor material is then applied in the form of a dry mixture of metal which adheres to the tacky pattern area. The assemblage is then fired to ash the photopolymer and sinter the conductor powder.
Demonstration of a Conduction Cooled React and Wind MgB2 Coil Segment for MRI Applications
Kim, H. S.; Kovacs, C.; Rindfleisch, M.; Yue, J.; Doll, D.; Tomsic, M.; Sumption, M. D.; Collings, E. W.
2016-01-01
This study is a contribution to the development of technology for an MgB2-based, cryogen-free, superconducting magnet for an MRI system. Specifically, we aim to demonstrate that a react and wind coil can be made using high performance in-situ route MgB2 conductor, and that the conductor could be operated in conduction mode with low levels of temperature gradient. In this work, an MgB2 conductor was used for the winding of a sub-size, MRI-like coil segment. The MgB2 coil was wound on a 457 mm ID 101 OFE copper former using a react-and-wind approach. The total length of conductor used was 330 m. The coil was epoxy impregnated and then instrumented for low temperature testing. After the initial cool down (conduction cooling) the coil Ic was measured as a function of temperature (15-30 K), and an Ic of 200 A at 15 K was measured. PMID:27857508
Making the case for high temperature low sag (htls) overhead transmission line conductors
NASA Astrophysics Data System (ADS)
Banerjee, Koustubh
The future grid will face challenges to meet an increased power demand by the consumers. Various solutions were studied to address this issue. One alternative to realize increased power flow in the grid is to use High Temperature Low Sag (HTLS) since it fulfills essential criteria of less sag and good material performance with temperature. HTLS conductors like Aluminum Conductor Composite Reinforced (ACCR) and Aluminum Conductor Carbon Composite (ACCC) are expected to face high operating temperatures of 150-200 degree Celsius in order to achieve the desired increased power flow. Therefore, it is imperative to characterize the material performance of these conductors with temperature. The work presented in this thesis addresses the characterization of carbon composite core based and metal matrix core based HTLS conductors. The thesis focuses on the study of variation of tensile strength of the carbon composite core with temperature and the level of temperature rise of the HTLS conductors due to fault currents cleared by backup protection. In this thesis, Dynamic Mechanical Analysis (DMA) was used to quantify the loss in storage modulus of carbon composite cores with temperature. It has been previously shown in literature that storage modulus is correlated to the tensile strength of the composite. Current temperature relationships of HTLS conductors were determined using the IEEE 738-2006 standard. Temperature rise of these conductors due to fault currents were also simulated. All simulations were performed using Microsoft Visual C++ suite. Tensile testing of metal matrix core was also performed. Results of DMA on carbon composite cores show that the storage modulus, hence tensile strength, decreases rapidly in the temperature range of intended use. DMA on composite cores subjected to heat treatment were conducted to investigate any changes in the variation of storage modulus curves. The experiments also indicates that carbon composites cores subjected to temperatures at or above 250 degree Celsius can cause permanent loss of mechanical properties including tensile strength. The fault current temperature analysis of carbon composite based conductors reveal that fault currents eventually cleared by backup protection in the event of primary protection failure can cause damage to fiber matrix interface.
The European Alps as an interrupter of the Earth's conductivity structures
NASA Astrophysics Data System (ADS)
Al-Halbouni, D.
2013-07-01
Joint interpretation of magnetotelluric and geomagnetic depth sounding results in the period range of 10-105 s in the Western European Alps offer new insights into the conductivity structure of the Earth's crust and mantle. This first large scale electromagnetic study in the Alps covers a cross-section from Germany to northern Italy and shows the importance of the alpine mountain chain as an interrupter of continuous conductors. Poor data quality due to the highly crystalline underground is overcome by Remote Reference and Robust Processing techniques and the combination of both electromagnetic methods. 3-D forward modeling reveals on the one hand interrupted dipping crustal conductors with maximum conductances of 4960 S and on the other hand a lithosphere thickening up to 208 km beneath the central Western Alps. Graphite networks arising from Palaeozoic sedimentary deposits are considered to be accountable for the occurrence of high conductivity and the distribution pattern of crustal conductors. The influence of huge sedimentary Molasse basins on the electromagnetic data is suggested to be minor compared with the influence of crustal conductors. Dipping direction (S-SE) and maximum angle (10.1°) of the northern crustal conductor reveal the main thrusting conditions beneath the Helvetic Alps whereas the existence of a crustal conductor in the Briançonnais supports theses about its belonging to the Iberian Peninsula. In conclusion the proposed model arisen from combined 3-D modeling of noise corrected electromagnetic data is able to explain the geophysical influence of various structural features in and around the Western European Alps and serves as a background for further upcoming studies.
Microelectronic components and metallic oxide studies and applications
NASA Technical Reports Server (NTRS)
Williams, L., Jr.
1976-01-01
The project involved work in two basic areas: (1) Evaluation of commercial screen printable thick film conductors, resistors, thermistors and dielectrics as well as alumina substrates used in hybird microelectronics industries. Results of tests made on materials produced by seven companies are presented. (2) Experimental studies on metallic oxides of copper and vanadium, in an effort to determine their electrochemical properties in crystalline, powder mixtures and as screen printable thick films constituted the second phase of the research effort. Oxide investigations were aimed at finding possible applications of these materials as switching devices memory elements and sensors.
NASA Technical Reports Server (NTRS)
1989-01-01
Electro-Expulsive Separation System, a low power electro-thermal deicer, was invented by Leonard A. Haslim from the Ames Research Center, who was named 1988 NASA Inventor of the Year for his work. Sold under license by Dataproducts New England, Inc., it consists of an elastic, rubber-like deicer boot on the wing's leading edge with copper ribbons embedded in it. Conductors are separated by slits in between and parallel to the ribbons. When the system is switched on, a bank of capacitors in the power supply discharges into the conductors which induces the conductor pairs to repel each other. This results in a powerful force causing the slit voids to expand explosively, removing ice on the wing. EESS is more flexible, more effective, and easier to maintain than previous systems. Potential ship, bridge and industrial applications are under study.
A study of electric transmission lines for use on the lunar surface
NASA Technical Reports Server (NTRS)
Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.
1994-01-01
The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.
NASA Astrophysics Data System (ADS)
Xiao, Ruijuan; Li, Hong; Chen, Liquan
2015-09-01
Looking for solid state electrolytes with fast lithium ion conduction is an important prerequisite for developing all-solid-state lithium secondary batteries. By combining the simulation techniques in different levels of accuracy, e.g. the bond-valence (BV) method and the density functional theory (DFT), a high-throughput design and optimization scheme is proposed for searching fast lithium ion conductors as candidate solid state electrolytes for lithium rechargeable batteries. The screening from more than 1000 compounds is performed through BV-based method, and the ability to predict reliable tendency of the Li+ migration energy barriers is confirmed by comparing with the results from DFT calculations. β-Li3PS4 is taken as a model system to demonstrate the application of this combination method in optimizing properties of solid electrolytes. By employing the high-throughput DFT simulations to more than 200 structures of the doping derivatives of β-Li3PS4, the effects of doping on the ionic conductivities in this material are predicted by the BV calculations. The O-doping scheme is proposed as a promising way to improve the kinetic properties of this materials, and the validity of the optimization is proved by the first-principles molecular dynamics (FPMD) simulations.
Natural deep eutectic solvents: cytotoxic profile.
Hayyan, Maan; Mbous, Yves Paul; Looi, Chung Yeng; Wong, Won Fen; Hayyan, Adeeb; Salleh, Zulhaziman; Mohd-Ali, Ozair
2016-01-01
The purpose of this study was to investigate the cytotoxic profiles of different ternary natural deep eutectic solvents (NADESs) containing water. For this purpose, five different NADESs were prepared using choline chloride as a salt, alongside five hydrogen bond donors (HBD) namely glucose, fructose, sucrose, glycerol, and malonic acid. Water was added as a tertiary component during the eutectics preparation, except for the malonic acid-based mixture. Coincidentally, the latter was found to be more toxic than any of the water-based NADESs. A trend was observed between the cellular requirements of cancer cells, the viscosity of the NADESs, and their cytotoxicity. This study also highlights the first time application of the conductor-like screening model for real solvent (COSMO-RS) software for the analysis of the cytotoxic mechanism of NADESs. COSMO-RS simulation of the interactions between NADESs and cellular membranes' phospholipids suggested that NADESs strongly interacted with cell surfaces and that their accumulation and aggregation possibly defined their cytotoxicity. This reinforced the idea that careful selection of NADESs components is necessary, as it becomes evident that organic acids as HBD highly contribute to the increasing toxicity of these neoteric mixtures. Nevertheless, NADESs in general seem to possess relatively less acute toxicity profiles than their DESs parents. This opens the door for future large scale utilization of these mixtures.
Kungwan, Nawee; Ngaojampa, Chanisorn; Ogata, Yudai; Kawatsu, Tsutomu; Oba, Yuki; Kawashima, Yukio; Tachikawa, Masanori
2017-10-05
Solvent dependence of double proton transfer in the formic acid-formamidine (FA-FN) complex at room temperature was investigated by means of ab initio path integral molecular dynamics (AIPIMD) simulation with taking nuclear quantum and thermal effects into account. The conductor-like screening model (COSMO) was applied for solvent effect. In comparison with gas phase, double proton delocalization between two heavy atoms (O and N) in FA-FN were observed with reduced proton transfer barrier height in low dielectric constant medium (<4.8). For dielectric constant medium at 4.8, the chance of finding these two protons are more pronounced due to the solvent effect which completely washes out the proton transfer barrier. In the case of higher dielectric constant medium (>4.8), the ionic species becomes more stable than the neutral ones and the formate anion and formamidium cation are thermodynamically stable. For ab initio molecular dynamics simulation, in low dielectric constant medium (<4.8) a reduction of proton transfer barrier with solvent effect is found to be less pronounced than the AIPIMD due to the absence of nuclear quantum effect. Moreover, the motions of FA-FN complex are significantly different with increasing dielectric constant medium. Such a difference is revealed in detail by the principal component analysis.
Jeschke, Steffen; Jankowski, Piotr; Best, Adam S; Johansson, Patrik
2018-03-12
Cyclodextrins (CDs) are pyranoside-based macromolecules with a hydrophobic cavity to encapsulate small molecules. They are used as molecular vehicles, for instance in pharmaceutical drug delivery or as solubility enhancer of monomers for their polymerization in aqueous solution. In this context, it was discovered about 10 years ago that the bis(trifluoromethylsulonyl)imide (TFSI) anion forms host-guest complexes with βCD in aqueous media. This sparked interest in using the TFSI anion in lithium-based battery electrolytes open for its encapsulation by βCD as an attractive approach to increase the contribution of the cation to the total ion conductivity. By using semi-empirical quantum mechanical (SQM) methods and the conductor-like screening model for a real solvent (COSMO-RS), a randomly methylated βCD (RMβCD) is here identified as a suitable host for TFSI when using organic solvents often used in battery technology. By combining molecular dynamics (MD) simulations with different NMR and FTIR experiments, the formation of the corresponding RMβCD-TFSI complex was investigated. Finally, the effects of the addition RMβCD to a set of electrolytes on the ion conductivity are measured and explained using three distinct scenarios. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Multiregion bicentric-spheres models of the head for the simulation of bioelectric phenomena.
Vatta, Federica; Bruno, Paolo; Inchingolo, Paolo
2005-03-01
Equations are derived for the electric potentials [electroencephalogram (EEG)] produced by dipolar sources in a multiregion bicentric-spheres volume-conductor head model. Being the equations valid for an arbitrary number of regions, our proposal is a generalization of many spherical models presented so far in literature, each of those regarded as a particular case of our multiregion model. Moreover, our approach allows considering new features of the head volume-conductor to better approximate electrical properties of the real head.
NASA Astrophysics Data System (ADS)
Wang, Gang; Wei, Wenbo; Ye, Gaofeng; Jin, Sheng; Jing, Jianen; Zhang, Letian; Dong, Hao; Xie, Chengliang; Omisore, Busayo O.; Guo, Zeqiu
2017-09-01
The approximately north-south trending Cenozoic Yadong-Gulu rift (YGR) in the eastern Lhasa block is an ideal location to investigate the extensional kinematic mechanism of the upper crust and the deformation characteristics of the Indian lithospheric slab in southern Tibet. The magnetotelluric (MT) method has been widely used in probing subsurface structures at lithospheric scale and is sensitive to high electrically conductive body (conductor). A three-dimensional (3-D) inversion of MT data was conducted to derive the east-west electrical structures across the northern segment of the YGR. The result reveals that the conductors in the middle crust are not continuous in the east-west direction. The deep conductor underneath the YGR is interpreted to result from the tearing of the Indian lithospheric slab. The upper crust to the east of the YGR is significantly intruded by underlying conductors. Based on the features of the 3-D inversion result from this study and other geophysical observations, the formation of the YGR is most likely caused by tearing of the Indian lithospheric slab through the pull of mid-lower crustal conductors that have locally weak strength beneath the YGR.
Cottingham, J.G.
1982-03-15
A mechanically stable, wound, multifilar, ribbon-type conductor is described having a cross-sectional aspect ratio which may be greater than 12:1, comprising a plurality of conductive strands wound to form a flattened helix containing a plastic strip into which the strands have been pressed so as to form a bond between the strip and the strands. The bond mechanically stabilizes the conductor under tension, preventing it from collapsing into a tubular configuration. In preferred embodiments the plastic strip may be polytetrafluoroethylene, and the conductive strands may be formed from a superconductive material. Conductors in accordance with the present invention may be manufactured by winding a plurality of conductive strands around a hollow mandrel; the cross-section of a hollow mandrel; the cross-section of the mandrel continuously varying from substnatially circular to a high aspect ratio elipse while maintaining a constant circumference. The wound conductive strands are drawn from the mandrel as a multifilar helix while simultaneously a plastic strip is fed through the hollow mandrel so that it is contained within the helix as it is withdrawn from the mandrel. The helical conductor is then compressed into a ribbon-like form and the strands are bonded to the plastic strip by a combination of heat and pressure.
Cottingham, James G.
1987-01-01
A mechanically stable, wound, multifilar, ribbon-type conductor having a cross-sectional aspect ratio which may be greater than 12:1, comprising a plurality of conductive strands wound to form a flattened helix containing a plastic strip into which the strands have been pressed so as to form a bond between the strip and the strands. The bond mechanically stabilizes the conductor under tension, preventing it from collapsing into a tubular configuration. In preferred embodiments the plastic strip may be polytetrafluoroethylene, and the conductive strands may be formed from a superconductive material. Conductors in accordance with the present invention may be manufactured by winding a plurality of conductive strands around a hollow mandrel; the cross-section of a hollow mandrel; the cross-section of the mandrel continuously varying from substantially circular to a high aspect ratio elipse while maintaining a constant circumference. The wound conductive strands are drawn from the mandrel as a multifilar helix while simultaneously a plastic strip is fed through the hollow mandrel so that it is contained within the helix as it is withdrawn from the mandrel. The helical conductor is then compressed into a ribbon-like form and the strands are bonded to the plastic strip by a combination of heat and pressure.
Cottingham, James G.
1987-11-03
A mechanically stable, wound, multifilar, ribbon-type conductor having a cross-sectional aspect ratio which may be greater than 12:1, comprising a plurality of conductive strands wound to form a flattened helix containing a plastic strip into which the strands have been pressed so as to form a bond between the strip and the strands. The bond mechanically stabilizes the conductor under tension, preventing it from collapsing into a tubular configuration. In preferred embodiments the plastic strip may be polytetrafluoroethylene, and the conductive strands may be formed from a superconductive material. Conductors in accordance with the present invention may be manufactured by winding a plurality of conductive strands around a hollow mandrel; the cross-section of a hollow mandrel; the cross-section of the mandrel continuously varying from substantially circular to a high aspect ratio elipse while maintaining a constant circumference. The wound conductive strands are drawn from the mandrel as a multifilar helix while simultaneously a plastic strip is fed through the hollow mandrel so that it is contained within the helix as it is withdrawn from the mandrel. The helical conductor is then compressed into a ribbon-like form and the strands are bonded to the plastic strip by a combination of heat and pressure.
Modesto-Costa, Lucas; Borges, Itamar
2018-08-05
The 4-N,N-dimethylaminobenzonitrile (DMABN) molecule is a prototypical system displaying twisted intramolecular (TICT) charge transfer effects. The ground and the first four electronic excited states (S 1 -S 4 ) in gas phase and upon solvation were studied. Charge transfer values as function of the torsion angle between the donor group (dimethylamine) and the acceptor moiety (benzonitrile) were explicitly computed. Potential energy curves were also obtained. The algebraic diagrammatic construction method at the second-order [ADC(2)] ab initio wave function was employed. Three solvents of increased polarities (benzene, DMSO and water) were investigated using discrete (average solvent electrostatic configuration - ASEC) and continuum (conductor-like screening model - COSMO) models. The results for the S 3 and S 4 excited states and the S 1 -S 4 charge transfer curves were not previously available in the literature. Electronic gas phase and solvent vertical spectra are in good agreement with previous theoretical and experimental results. In the twisted (90°) geometry the optical oscillator strengths have negligible values even for the S 2 bright state. Potential energy curves show two distinct pairs of curves intersecting at decreasing angles or not crossing in the more polar solvents. Charge transfer and electric dipole values allowed the rationalization of these results. The former effects are mostly independent of the solvent model and polarity. Although COSMO and ASEC solvent models mostly lead to similar results, there is an important difference: some crossings of the excitation energy curves appear only in the ASEC solvation model, which has important implications to the photochemistry of DMABN. Copyright © 2018 Elsevier B.V. All rights reserved.
Toward Paradoxical Inconsistency in Electrostatics of Metallic Conductors
Naturally, when dealing with fundamental problems, the V and V effort should include careful exploration and, if necessary, revision of the fundamentals...Current developments show a clear trend toward more serious efforts in validation and verification (V and V) of physical and engineering models...underlying the physics. With this understanding in mind, we review some fundamentals of the models of crystalline electric conductors and find a
Effects of particle size distribution in thick film conductors
NASA Technical Reports Server (NTRS)
Vest, R. W.
1983-01-01
Studies of particle size distribution in thick film conductors are discussed. The distribution of particle sizes does have an effect on fired film density but the effect is not always positive. A proper distribution of sizes is necessary, and while the theoretical models can serve as guides to selecting this proper distribution, improved densities can be achieved by empirical variations from the predictions of the models.
Analysis of the ITER central solenoid insert (CSI) coil stability tests
NASA Astrophysics Data System (ADS)
Savoldi, L.; Bonifetto, R.; Breschi, M.; Isono, T.; Martovetsky, N.; Ozeki, H.; Zanino, R.
2017-07-01
At the end of the test campaign of the ITER Central Solenoid Insert (CSI) coil in 2015, after 16,000 electromagnetic (EM) cycles, some tests were devoted to the study of the conductor stability, through the measurement of the Minimum Quench Energy (MQE). The tests were performed by means of an inductive heater (IH), located in the high-field region of the CSI and wrapped around the conductor. The calorimetric calibration of the IH is presented here, aimed at assessing the energy deposited in the conductor for different values of the IH electrical operating conditions. The MQE of the conductor of the ITER CS module 3L can be estimated as ∼200 J ± 20%, deposited on the whole conductor on a length of ∼10 cm (the IH length) in ∼40 ms, at current and magnetic field conditions relevant for the ITER CS operation. The repartition of the energy deposited in the conductor under the IH is computed to be ∼10% in the cable and 90% in the jacket by means of a 3D Finite Elements EM model. It is shown how this repartition implies that the bundle (cable + helium) heat capacity is fully available for stability on the time scale of the tested disturbances. This repartition is used in input to the thermal-hydraulic analysis performed with the 4C code, to assess the capability of the model to accurately reproduce the stability threshold of the conductor. The MQE computed by the code for this disturbance is in good agreement with the measured value, with an underestimation within 15% of the experimental value.
NASA Astrophysics Data System (ADS)
Sakai, Masamichi; Takao, Hiraku; Matsunaga, Tomoyoshi; Nishimagi, Makoto; Iizasa, Keitaro; Sakuraba, Takahito; Higuchi, Koji; Kitajima, Akira; Hasegawa, Shigehiko; Nakamura, Osamu; Kurokawa, Yuichiro; Awano, Hiroyuki
2018-03-01
We have proposed an enhancement mechanism of the Hall effect, the signal of which is amplified due to the generation of a sustaining mode of spin current. Our analytic derivations of the Hall resistivity revealed the conditions indispensable for the observation of the effect: (i) the presence of the transverse component of an effective electric field due to spin splitting in chemical potential in addition to the longitudinal component; (ii) the simultaneous presence of holes and electrons each having approximately the same characteristics; (iii) spin-polarized current injection from magnetized electrodes; (iv) the boundary condition for the transverse current (J c, y = 0). The model proposed in this study was experimentally verified by using van der Pauw-type Hall devices consisting of the nonmagnetic bipolar conductor YH x (x ≃ 2) and TbFeCo electrodes. Replacing Au electrodes with TbFeCo electrodes alters the Hall resistivity from the ordinary Hall effect to the anomalous Hall-like effect with an enhancement factor of approximately 50 at 4 T. We interpreted the enhancement phenomenon in terms of the present model.
Drude conductivity exhibited by chemically synthesized reduced graphene oxide
NASA Astrophysics Data System (ADS)
Younas, Daniyal; Javed, Qurat-ul-Ain; Fatima, Sabeen; Kalsoom, Riffat; Abbas, Hussain; Khan, Yaqoob
2017-09-01
Electrical conductance in graphene layers having Drude like response due to massless Dirac fermions have been well explained theoretically as well as experimentally. In this paper Drude like electrical conductivity response of reduced graphene oxide synthesized by chemical route is presented. A method slightly different from conventional methods is used to synthesize graphene oxide which is then converted to reduced graphene oxide. Various analytic techniques were employed to verify the successful oxidation and reductions in the process and were also used to measure various parameters like thickness of layers and conductivity. Obtained reduced graphene oxide has very thin layers of thickness around 13 nm on average and reduced graphene oxide has average thickness below 20 nm. Conductivity of the reduced graphene was observed to have Drude like response which is explained on basis of Drude model for conductors.
Physics of Electronic Materials
NASA Astrophysics Data System (ADS)
Rammer, Jørgen
2017-03-01
1. Quantum mechanics; 2. Quantum tunneling; 3. Standard metal model; 4. Standard conductor model; 5. Electric circuit theory; 6. Quantum wells; 7. Particle in a periodic potential; 8. Bloch currents; 9. Crystalline solids; 10. Semiconductor doping; 11. Transistors; 12. Heterostructures; 13. Mesoscopic physics; 14. Arithmetic, logic and machines; Appendix A. Principles of quantum mechanics; Appendix B. Dirac's delta function; Appendix C. Fourier analysis; Appendix D. Classical mechanics; Appendix E. Wave function properties; Appendix F. Transfer matrix properties; Appendix G. Momentum; Appendix H. Confined particles; Appendix I. Spin and quantum statistics; Appendix J. Statistical mechanics; Appendix K. The Fermi-Dirac distribution; Appendix L. Thermal current fluctuations; Appendix M. Gaussian wave packets; Appendix N. Wave packet dynamics; Appendix O. Screening by symmetry method; Appendix P. Commutation and common eigenfunctions; Appendix Q. Interband coupling; Appendix R. Common crystal structures; Appendix S. Effective mass approximation; Appendix T. Integral doubling formula; Bibliography; Index.
NASA Astrophysics Data System (ADS)
Anota, E. Chigo; Villanueva, M. Salazar; Shakerzadeh, E.; Castro, M.
2018-02-01
The adsorption, activation and possible dissociation of the glucose molecule on the magnetic [BN fullerene-B6]- system is performed by means of density functional theory calculations. Three models of magnetic nanocomposites were inspected: i) pristine BN fullerene, BN fullerene functionalized with a magnetic B6 cluster which generates two structures: ii) pyramidal (P) and iii) triangular (T). Chemical interactions of glucose appear for all these cases; however, for the BNF:B6(T)—glucose system, the interaction generates an effect of dissociation on glucose, due to the magnetic effects, since it has high spin multiplicity. The latter nanocomposite shows electronic behavior like-conductor and like-semi-conductor for the P and T geometries, respectively. Intrinsic magnetism associated to values of 1.0 magneton bohr (µB) for the pyramidal and 5.0 µB for the triangular structure, high polarity, and low-chemical reactivity are found for these systems. These interesting properties make these functionalized fullerenes a good option for being used as nano-vehicles for drug delivery. These quantum descriptors remain invariant when the [BN]-fullerene and [BNF:B6 (P) or (T)]- nanocomposites are interacting with the glucose molecule. According to the determined adsorption energy, chemisorption regimes occur in both the phases: gas and aqueous medium.
Thermal protection system ablation sensor
NASA Technical Reports Server (NTRS)
Gorbunov, Sergey (Inventor); Martinez, Edward R. (Inventor); Scott, James B. (Inventor); Oishi, Tomomi (Inventor); Fu, Johnny (Inventor); Mach, Joseph G. (Inventor); Santos, Jose B. (Inventor)
2011-01-01
An isotherm sensor tracks space vehicle temperatures by a thermal protection system (TPS) material during vehicle re-entry as a function of time, and surface recession through calibration, calculation, analysis and exposed surface modeling. Sensor design includes: two resistive conductors, wound around a tube, with a first end of each conductor connected to a constant current source, and second ends electrically insulated from each other by a selected material that becomes an electrically conductive char at higher temperatures to thereby complete an electrical circuit. The sensor conductors become shorter as ablation proceeds and reduced resistance in the completed electrical circuit (proportional to conductor length) is continually monitored, using measured end-to-end voltage change or current in the circuit. Thermocouple and/or piezoelectric measurements provide consistency checks on local temperatures.
Overheating instability of a thin conductor with respect to stratification
NASA Astrophysics Data System (ADS)
Garanin, S. F.; Kuznetsov, S. D.
2018-04-01
We consider an overheating instability of a thin (compared to the skin depth) conductor with respect to stratification at the stage when its resistivity rises up to an electrical explosion. Temperature perturbations under such conditions are shown to grow in proportion to resistivity. In the model, when resistivity is proportional to temperature, perturbations grow in proportion to temperature and hence exhibit no relative growth. For a conductor with initial thickness perturbations, temperature perturbations grow in proportion to resistivity and current action integral, i.e., somewhat faster than perturbations in the problem of constant thickness conductors. Comparison of our results with simulations of the growth of stratification during electrical heating of foils in warm dense matter generation systems demonstrates their close agreement.
NASA Astrophysics Data System (ADS)
Kololuoma, Terho K.; Tuomikoski, Markus; Makela, Tapio; Heilmann, Jali; Haring, Tomi; Kallioinen, Jani; Hagberg, Juha; Kettunen, Ilkka; Kopola, Harri K.
2004-06-01
Embedding of optoelectrical, optical, and electrical functionalities into low-cost products like packages and printed matter can be used to increase their information content. These functionalities make also possible the realization of new type of entertaining, impressive or guiding effects on the product packages and printed matter. For these purposes, components like displays, photodetectors, light sources, solar cells, battery elements, diffractive optical elements, lightguides, electrical conductors, resistors, transistors, switching elements etc. and their integration to functional modules are required. Additionally, the price of the components for low-end products has to be in cent scale or preferably below that. Therefore, new, cost-effective, and volume scale capable manufacturing techniques are required. Recent developments of liquid-phase processable electrical and optical polymeric, inorganic, and hybrid materials - inks - have made it possible to fabricate functional electrical, optical and optoelectrical components by conventional roll-to-roll techniques such as gravure printing, embossing, digital printing, offset, and screen printing on flexible paper and plastic like substrates. In this paper, we show our current achievements in the field of roll-to-roll fabricated, optics, electronics and optoelectronics. With few examples, we also demonstrate the printing and hot-embossing capabilities of table scale printing machines and VTT Electronic's 'PICO' roll-to-roll pilot production facility.
Haufe, Stefan; Huang, Yu; Parra, Lucas C
2015-08-01
In electroencephalographic (EEG) source imaging as well as in transcranial current stimulation (TCS), it is common to model the head using either three-shell boundary element (BEM) or more accurate finite element (FEM) volume conductor models. Since building FEMs is computationally demanding and labor intensive, they are often extensively reused as templates even for subjects with mismatching anatomies. BEMs can in principle be used to efficiently build individual volume conductor models; however, the limiting factor for such individualization are the high acquisition costs of structural magnetic resonance images. Here, we build a highly detailed (0.5mm(3) resolution, 6 tissue type segmentation, 231 electrodes) FEM based on the ICBM152 template, a nonlinear average of 152 adult human heads, which we call ICBM-NY. We show that, through more realistic electrical modeling, our model is similarly accurate as individual BEMs. Moreover, through using an unbiased population average, our model is also more accurate than FEMs built from mismatching individual anatomies. Our model is made available in Matlab format.
NASA Astrophysics Data System (ADS)
Bologna, Mauricio S.; Egbert, Gary D.; Padilha, Antonio L.; Pádua, Marcelo B.; Vitorello, Ícaro
2017-09-01
We present a magnetotelluric (MT) study in the northeastern part of the São Francisco Craton that encompasses an Archean-Proterozoic terrain, the Serrinha Block, breached by a rift basin developed mostly in Early Cretaceous times during the opening of the South Atlantic Ocean. Even though the MT sites are regularly spaced, the profiles have different orientations from one another, making the data distribution over the area highly uneven and therefore non-ideal for 3-D modeling. However, the data set is very complex, with dimensionality analysis indicating prevalence of 3-D geoelectric structure. Results from 3-D inversion are evaluated for robustness and potentiality for yielding tectonic information. At upper crustal depths, the resulting 3-D model is coherent with surface geology, whereas at mid and lower crustal depths more cryptic structures are revealed, likely of Palaeoproterozoic age. The most striking features in the model are several strong (∼1 Ωṡm) crustal conductors beneath the central part of the Serrinha Block, which we attribute to a Palaeoproterozoic oceanic plate subduction and arc-continent collision event involving the Rio Itapicuru Greenstone Belt and the basement of the Serrinha Block. The west-dipping geometry of these conductors provides a constraint on subduction polarity and gives support to tectonic evolutionary models proposing that the Rio Itapicuru Belt was formed in an island arc environment.
Water solvent effects using continuum and discrete models: The nitromethane molecule, CH3NO2.
Modesto-Costa, Lucas; Uhl, Elmar; Borges, Itamar
2015-11-15
The first three valence transitions of the two nitromethane conformers (CH3NO2) are two dark n → π* transitions and a very intense π → π* transition. In this work, these transitions in gas-phase and solvated in water of both conformers were investigated theoretically. The polarizable continuum model (PCM), two conductor-like screening (COSMO) models, and the discrete sequential quantum mechanics/molecular mechanics (S-QM/MM) method were used to describe the solvation effect on the electronic spectra. Time dependent density functional theory (TDDFT), configuration interaction including all single substitutions and perturbed double excitations (CIS(D)), the symmetry-adapted-cluster CI (SAC-CI), the multistate complete active space second order perturbation theory (CASPT2), and the algebraic-diagrammatic construction (ADC(2)) electronic structure methods were used. Gas-phase CASPT2, SAC-CI, and ADC(2) results are in very good agreement with published experimental and theoretical spectra. Among the continuum models, PCM combined either with CASPT2, SAC-CI, or B3LYP provided good agreement with available experimental data. COSMO combined with ADC(2) described the overall trends of the transition energy shifts. The effect of increasing the number of explicit water molecules in the S-QM/MM approach was discussed and the formation of hydrogen bonds was clearly established. By including explicitly 24 water molecules corresponding to the complete first solvation shell in the S-QM/MM approach, the ADC(2) method gives more accurate results as compared to the TDDFT approach and with similar computational demands. The ADC(2) with S-QM/MM model is, therefore, the best compromise for accurate solvent calculations in a polar environment. © 2015 Wiley Periodicals, Inc.
Particle trap for compressed gas insulated transmission systems
Cookson, A.H.
1984-04-26
A particle trap is provided for gas insulated transmission lines having a central high voltage conductor supported within an outer coaxial conductive sheath by a dielectric support member. A cavity between the inner conductor and outer sheath is filled with a dielectric insulating gas. A cone-like particle deflector, mounted to the inner conductor, deflects moving particles away from the support member, to radially outer portions of the cavity. A conductive shield is disposed adjacent the outer sheath to form a field-free region in radially outer portions of the cavity, between the shield and the sheath. Particles traveling along the cavity are deflected by the cone-like deflector into the field-free region where they are held immobile. In a vertical embodiment, particles enter the field-free region through an upper end of a gap formed between shield and sheath members. In a horizontal embodiment, the deflector cone has a base which is terminated radially internally of the shield. Apertures in the shield located adjacent the deflector allow passage of deflected particles into the field-free region. The dielectric support member is thereby protected from contaminating particles that may otherwise come to rest thereon.
Particle trap for compressed gas insulated transmission systems
Cookson, Alan H.
1985-01-01
A particle trap is provided for gas insulated transmission lines having a central high voltage conductor supported within an outer coaxial conductive sheath by a dielectric support member. A cavity between the inner conductor and outer sheath is filled with a dielectric insulating gas. A cone-like particle deflector, mounted to the inner conductor, deflects moving particles away from the support member, to radially outer portions of the cavity. A conductive shield is disposed adjacent the outer sheath to form a field-free region in radially outer portions of the cavity, between the shield and the sheath. Particles traveling along the cavity are deflected by the cone-like deflector into the field-free region where they are held immobile. In a vertical embodiment, particles enter the field-free region through an upper end of a gap formed between shield and sheath members. In a horizontal embodiment, the deflector cone has a base which is terminated radially internally of the shield. Apertures in the shield located adjacent the deflector allow passage of deflected particles into the field-free region. The dielectric support member is thereby protected from contaminating particles that may otherwise come to rest thereon.
Preparing the Conductor as Teacher
ERIC Educational Resources Information Center
Ulrich, Jerry
2009-01-01
While music is as old as humanity, conducting as a profession is relatively new. Although a nineteenth-century model has served as the template for the training of conductors, many undergraduate conducting students will spend their teaching careers working with inexperienced and/or amateur musicians. Additionally, the size of many ensembles in…
NASA Astrophysics Data System (ADS)
Iváncsy, T.; Kiss, I.; Szücs, L.; Tamus, Z. Á.
2015-10-01
The lightning current generates time-varying magnetic field near the down- conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts. In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated.
NASA Astrophysics Data System (ADS)
Xu, Zhongtang; Yuan, Pusheng; Ma, Yanwei; Cai, Chuanbing
2017-03-01
We report on the transport properties of FeSe0.5Te0.5 (FST) thin films fabricated on less-well-textured flexible coated conductor templates with LaMnO3 (LMO) as buffer layers using pulsed laser deposition. The LMO buffer layers exhibit large in-plane misalignment of ˜7.72°, which is unfavorable for cuprate-coated conductors due to the high grain boundaries. The FST thin films show a superconducting transition temperature of 16.8 K, higher than that of bulk materials due to the compressive strain between LMO and FST. Atomic force microscopy observations reveal that island-like features appear at the surfaces of both LMO and FST, confirming the island growth mode. A self-field transport critical-current density of up to 0.43 MA cm-2 at 4.2 K has been observed in FST thin films, which is much higher than that in powder-in-tube processed FST tapes. The films are capable of carrying current densities of over 105 A cm-2 in the whole applied magnetic field up to 9 T, showing great potential for high-field applications. The results indicate that, for FST, highly textured metal tapes are not needed to produce coated conductors with high performance, which is of great advantage over cuprate-coated conductors.
Characterization of the ITER CS conductor and projection to the ITER CS performance
Martovetsky, N.; Isono, T.; Bessette, D.; ...
2017-06-20
The ITER Central Solenoid (CS) is one of the critical elements of the machine. The CS conductor went through an intense optimization and qualification program, which included characterization of the strands, a conductor straight short sample testing in the SULTAN facility at the Swiss Plasma Center (SPC), Villigen, Switzerland, and a single-layer CS Insert coil recently tested in the Central Solenoid Model Coil (CSMC) facility in QST-Naka, Japan. In this paper, we obtained valuable data in a wide range of the parameters (current, magnetic field, temperature, and strain), which allowed a credible characterization of the CS conductor in different conditions.more » Finally, using this characterization, we will make a projection to the performance of the CS in the ITER reference scenario.« less
Characterization of the ITER CS conductor and projection to the ITER CS performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martovetsky, N.; Isono, T.; Bessette, D.
The ITER Central Solenoid (CS) is one of the critical elements of the machine. The CS conductor went through an intense optimization and qualification program, which included characterization of the strands, a conductor straight short sample testing in the SULTAN facility at the Swiss Plasma Center (SPC), Villigen, Switzerland, and a single-layer CS Insert coil recently tested in the Central Solenoid Model Coil (CSMC) facility in QST-Naka, Japan. In this paper, we obtained valuable data in a wide range of the parameters (current, magnetic field, temperature, and strain), which allowed a credible characterization of the CS conductor in different conditions.more » Finally, using this characterization, we will make a projection to the performance of the CS in the ITER reference scenario.« less
Packaging printed circuit boards: A production application of interactive graphics
NASA Technical Reports Server (NTRS)
Perrill, W. A.
1975-01-01
The structure and use of an Interactive Graphics Packaging Program (IGPP), conceived to apply computer graphics to the design of packaging electronic circuits onto printed circuit boards (PCB), were described. The intent was to combine the data storage and manipulative power of the computer with the imaginative, intuitive power of a human designer. The hardware includes a CDC 6400 computer and two CDC 777 terminals with CRT screens, light pens, and keyboards. The program is written in FORTRAN 4 extended with the exception of a few functions coded in COMPASS (assembly language). The IGPP performs four major functions for the designer: (1) data input and display, (2) component placement (automatic or manual), (3) conductor path routing (automatic or manual), and (4) data output. The most complex PCB packaged to date measured 16.5 cm by 19 cm and contained 380 components, two layers of ground planes and four layers of conductors mixed with ground planes.
Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies.
Guerin, Bastien; Serano, Peter; Iacono, Maria Ida; Herrington, Todd M; Widge, Alik S; Dougherty, Darin D; Bonmassar, Giorgio; Angelone, Leonardo M; Wald, Lawrence L
2018-05-04
We propose a framework for electromagnetic (EM) simulation of deep brain stimulation (DBS) patients in radiofrequency (RF) coils. We generated a model of a DBS patient using post-operative head and neck computed tomography (CT) images stitched together into a 'virtual CT' image covering the entire length of the implant. The body was modeled as homogeneous. The implant path extracted from the CT data contained self-intersections, which we corrected automatically using an optimization procedure. Using the CT-derived DBS path, we built a model of the implant including electrodes, helicoidal internal conductor wires, loops, extension cables, and the implanted pulse generator. We also built four simplified models with straight wires, no extension cables and no loops to assess the impact of these simplifications on safety predictions. We simulated EM fields induced by the RF birdcage body coil in the body model, including at the DBS lead tip at both 1.5 Tesla (64 MHz) and 3 Tesla (123 MHz). We also assessed the robustness of our simulation results by systematically varying the EM properties of the body model and the position and length of the DBS implant (sensitivity analysis). The topology correction algorithm corrected all self-intersection and curvature violations of the initial path while introducing minimal deformations (open-source code available at http://ptx.martinos.org/index.php/Main_Page). The unaveraged lead-tip peak SAR predicted by the five DBS models (0.1 mm resolution grid) ranged from 12.8 kW kg -1 (full model, helicoidal conductors) to 43.6 kW kg -1 (no loops, straight conductors) at 1.5 T (3.4-fold variation) and 18.6 kW kg -1 (full model, straight conductors) to 73.8 kW kg -1 (no loops, straight conductors) at 3 T (4.0-fold variation). At 1.5 T and 3 T, the variability of lead-tip peak SAR with respect to the conductivity ranged between 18% and 30%. Variability with respect to the position and length of the DBS implant ranged between 9.5% and 27.6%.
Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies
NASA Astrophysics Data System (ADS)
Guerin, Bastien; Serano, Peter; Iacono, Maria Ida; Herrington, Todd M.; Widge, Alik S.; Dougherty, Darin D.; Bonmassar, Giorgio; Angelone, Leonardo M.; Wald, Lawrence L.
2018-05-01
We propose a framework for electromagnetic (EM) simulation of deep brain stimulation (DBS) patients in radiofrequency (RF) coils. We generated a model of a DBS patient using post-operative head and neck computed tomography (CT) images stitched together into a ‘virtual CT’ image covering the entire length of the implant. The body was modeled as homogeneous. The implant path extracted from the CT data contained self-intersections, which we corrected automatically using an optimization procedure. Using the CT-derived DBS path, we built a model of the implant including electrodes, helicoidal internal conductor wires, loops, extension cables, and the implanted pulse generator. We also built four simplified models with straight wires, no extension cables and no loops to assess the impact of these simplifications on safety predictions. We simulated EM fields induced by the RF birdcage body coil in the body model, including at the DBS lead tip at both 1.5 Tesla (64 MHz) and 3 Tesla (123 MHz). We also assessed the robustness of our simulation results by systematically varying the EM properties of the body model and the position and length of the DBS implant (sensitivity analysis). The topology correction algorithm corrected all self-intersection and curvature violations of the initial path while introducing minimal deformations (open-source code available at http://ptx.martinos.org/index.php/Main_Page). The unaveraged lead-tip peak SAR predicted by the five DBS models (0.1 mm resolution grid) ranged from 12.8 kW kg‑1 (full model, helicoidal conductors) to 43.6 kW kg‑1 (no loops, straight conductors) at 1.5 T (3.4-fold variation) and 18.6 kW kg‑1 (full model, straight conductors) to 73.8 kW kg‑1 (no loops, straight conductors) at 3 T (4.0-fold variation). At 1.5 T and 3 T, the variability of lead-tip peak SAR with respect to the conductivity ranged between 18% and 30%. Variability with respect to the position and length of the DBS implant ranged between 9.5% and 27.6%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flanagan, Gene
Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb 3Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber opticmore » sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh backscattered laser signals that are shifted by the changes in the fiber that are induced by a local change in the YBCO temperature or strain. One goal of this project was to show that modern technology can be used to interrogate the signals from a (very expensive) YBCO magnet to detect an impending quench in time to protect it from self-destruction. The results show that Rayleigh-backscattering interrogated optical fibers (RIOF) have significant advantages over traditional techniques, including very high spatial resolution and the ability to detect a hot-spot well before the peak local temperature becomes so high that the conductor can be damaged. RIOF quench detection is intrinsically faster than voltage taps, and this intrinsic advantage is greater as the coil size and/or current margin increases. We describe the development and testing program performed under the grant.« less
DOT National Transportation Integrated Search
2013-10-01
This document provides a step-by-step description of the design and execution of a strategic job analysis, using the position of Freight Conductor as an example. This document was created to be useful for many different needs, and can be used as an e...
A Classroom Activity for Teaching Electric Polarization of Insulators and Conductors
ERIC Educational Resources Information Center
Deligkaris, Christos
2018-01-01
The phenomenon of electric polarization is crucial to student understanding of forces exerted between charged objects and insulators or conductors, the process of charging by induction, and the behavior of electroscopes near charged objects. In addition, polarization allows for microscopic-level models of everyday-life macroscopic-level phenomena.…
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.
Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha
2017-05-01
Atrial fibrillation (AF) is a common cardiac arrhythmia that increases the risk of thromboembolic events. Anticoagulation therapy to prevent AF-related stroke has been shown to be cost-effective. A national screening programme for AF may prevent AF-related events, but would involve a substantial investment of NHS resources. To conduct a systematic review of the diagnostic test accuracy (DTA) of screening tests for AF, update a systematic review of comparative studies evaluating screening strategies for AF, develop an economic model to compare the cost-effectiveness of different screening strategies and review observational studies of AF screening to provide inputs to the model. Systematic review, meta-analysis and cost-effectiveness analysis. Primary care. Adults. Screening strategies, defined by screening test, age at initial and final screens, screening interval and format of screening {systematic opportunistic screening [individuals offered screening if they consult with their general practitioner (GP)] or systematic population screening (when all eligible individuals are invited to screening)}. Sensitivity, specificity and diagnostic odds ratios; the odds ratio of detecting new AF cases compared with no screening; and the mean incremental net benefit compared with no screening. Two reviewers screened the search results, extracted data and assessed the risk of bias. A DTA meta-analysis was perfomed, and a decision tree and Markov model was used to evaluate the cost-effectiveness of the screening strategies. Diagnostic test accuracy depended on the screening test and how it was interpreted. In general, the screening tests identified in our review had high sensitivity (> 0.9). Systematic population and systematic opportunistic screening strategies were found to be similarly effective, with an estimated 170 individuals needed to be screened to detect one additional AF case compared with no screening. Systematic opportunistic screening was more likely to be cost-effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.
Electrowetting on semiconductors
NASA Astrophysics Data System (ADS)
Palma, Cesar; Deegan, Robert
2015-01-01
Applying a voltage difference between a conductor and a sessile droplet sitting on a thin dielectric film separating it from the conductor will cause the drop to spread. When the conductor is a good metal, the change of the drop's contact angle due to the voltage is given by the Young-Lippmann (YL) equation. Here, we report experiments with lightly doped, single crystal silicon as the conductive electrode. We derive a modified YL equation that includes effects due to the semiconductor and contact line pinning. We show that light induces a non-reversible wetting transition, and that our model agrees well with our experimental results.
Modelling Near-Surface Metallic Clutter Without the Excruciating Pain
NASA Astrophysics Data System (ADS)
Downs, C. M.; Weiss, C. J.; Bach, J.; Williams, J. T.
2016-12-01
An ongoing problem in modeling electromagnetic (EM) interactions with the near-surface and related anthropogenic metal clutter is the large difference in length scale between the clutter dimensions and their resulting EM response. For example, observational evidence shows that cables, pipes and rail lines can have a strong influence far from where they are located, even in situations where these artefacts are volumetrically insignificant over the scale of the model. This poses a significant modeling problem for understanding geohazards in urban environments, for example, because of the very fine numerical discretization required for accurate representation of an artefact embedded in a larger computational domain. We adopt a sub-grid approximation and impose a boundary condition along grid edges to capture the vanishing fields of a perfect conductor. We work in a Cartesian system where the EM fields are solved via finite volumes in the frequency domain in terms of the Lorenz gauged magnetic vector (A) and electric scalar (Phi) potentials. The electric fied is given simply by A-grad(Phi), and set identically to zero along edges of the mesh that coincide with the center of long, slender metallic conductors. A simple extension to bulky artefacts like blocks or slabs involves endowing all such edges in their interior with the same "internal" boundary condition. In essence, we apply the "perfect electric conductor" boundary condition to select edges interior to the modeling domain. We note a few minor numerical consequences of this approach, namely: the zero-E field internal boundary condition destroys the symmetry of the finite volume coefficient matrix; and, the accuracy of the representation of the conducting artefact is restricted by the relatively coarse discretization mesh. The former is overcome with the use of preconditioned bi-conjugate gradient methods instead of the quasi-minimal-residual method. Both are matrix-free iterative solvers - thus avoiding unnecessary storage- and both exhibit generally good convergence for well-posed problems. The latter is more difficult to overcome without either modifying the mesh (potentially degrading the condition number of the coefficient matrix) or with novel mesh sub-gridding. Initial results show qualitative agreement with the expected physics.
Photoelectron Pumped Phosphors,
1989-07-01
result of SEE, if the screen is made from a dielectric or a semi- conductor with a high resistivity . The CL brightness depends on the energy of the...1. The rare-earth ion activated high resistance phos- phors based on the materials with garnet, spinel and diamond structure can be considered as the...most prospective CL materials, especially in the compounds that include the rare-earth elements in their host matrix. 2. The low resistance CL oxides
Analysis of Drop Shapes during Electrowetting on a Dielectric
NASA Astrophysics Data System (ADS)
Daneshbod, Yousef
2005-03-01
Electrowetting refers to the electrostatic control of the interfacial energy of a liquid on a solid, primarily used for the transport of micro-liter volumes of drops on surfaces with embedded electrode arrays. In the present work, the drop is modeled as a two-dimensional lens-like conductor immersed in an infinite dielectric medium slightly above a planar conductor. A matched asymptotic expansion is used to approximate the electrostatic field surrounding the drop. The outer problem models the drop as a conducting circular segment resting on the conducting plane, each maintained at a separate constant potential. The inner problem corrects the region near the edge of the drop by modeling it as an infinite planar conducting wedge lying slightly above the conducting plane. By matching the inner and outer solutions, the charge density along the entire surface of the drop can be approximated, enabling the calculation of the total capacitance of the system. An energy minimization method similar to that of Shapiro et al. [J. Appl. Phys., 93, 5794 (2003)] is applied to the total energy consisting of the liquid/gas, liquid/solid and solid/gas surface energies, together with the electrostatic contribution, subject to the constraint that the drop volume remains constant. A modified form of the Young-Lippmann equation is thus derived that includes the contribution from the extra capacitance of the drop obtained via matched asymptotics.
Kink modes and surface currents associated with vertical displacement events
NASA Astrophysics Data System (ADS)
Manickam, Janardhan; Boozer, Allen; Gerhardt, Stefan
2012-08-01
The fast termination phase of a vertical displacement event (VDE) in a tokamak is modeled as a sequence of shrinking equilibria, where the core current profile remains constant so that the safety-factor at the axis, qaxis, remains fixed and the qedge systematically decreases. At some point, the n = 1 kink mode is destabilized. Kink modes distort the magnetic field lines outside the plasma, and surface currents are required to nullify the normal component of the B-field at the plasma boundary and maintain equilibrium at finite pressure. If the plasma touches a conductor, the current can be transferred to the conductor, and may be measurable by the halo current monitors. This report describes a practical method to model the plasma as it evolves during a VDE, and determine the surface currents, needed to maintain equilibrium. The main results are that the onset conditions for the disruption are that the growth-rate of the n = 1 kink exceeds half the Alfven time and the associated surface current needed to maintain equilibrium exceeds one half of the core plasma current. This occurs when qedge drops below a low integer, usually 2. Application to NSTX provides favorable comparison with non-axisymmetric halo-current measurements. The model is also applied to ITER and shows that the 2/1 mode is projected to be the most likely cause of the final disruption.
Influence of magnetic materials on the transport properties of superconducting composite conductors
NASA Astrophysics Data System (ADS)
Glowacki, B. A.; Majoros, M.; Campbell, A. M.; Hopkins, S. C.; Rutter, N. A.; Kozlowski, G.; Peterson, T. L.
2009-03-01
Magnetic materials can help to improve the performance of practical superconductors on the macro/microscale as magnetic diverters and also on the nanoscale as effective pinning centres. It has been established by numerical modelling that magnetic shielding of the filaments reduces ac losses in self-field conditions due to decoupling of the filaments and, at the same time, it increases the critical current of the composite. This effect is especially beneficial for coated conductors, in which the anisotropic properties of the superconductor are amplified by the conductor architecture. However, ferromagnetic coatings are often chemically incompatible with YBa2Cu3O7 and (Pb,Bi)2Sr2Ca2Cu3O9 conductors, and buffer layers have to be used. In contrast, in MgB2 conductors an iron matrix may remain in direct contact with the superconducting core. The application of superconducting-magnetic heterostructures requires consideration of the thermal and electromagnetic stability of the superconducting materials used. On the one hand, magnetic components reduce the critical current gradient across the individual filaments but, on the other hand, they often reduce the thermal conductivity between the superconducting core and the cryogen, which may cause the destruction of the conductor in the event of thermal instability. A possible nanoscale method of improving the critical current density of superconducting conductors is the introduction of sub-micron magnetic pinning centres. However, the volumetric density and chemical compatibility of magnetic inclusions has to be controlled to avoid suppression of the superconducting properties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, S.; Li, Y.; Liu, C.
2015-08-15
This paper presents a statistical theory for the initial onset of multipactor breakdown in coaxial transmission lines, taking both the nonuniform electric field and random electron emission velocity into account. A general numerical method is first developed to construct the joint probability density function based on the approximate equation of the electron trajectory. The nonstationary dynamics of the multipactor process on both surfaces of coaxial lines are modelled based on the probability of various impacts and their corresponding secondary emission. The resonant assumption of the classical theory on the independent double-sided and single-sided impacts is replaced by the consideration ofmore » their interaction. As a result, the time evolutions of the electron population for exponential growth and absorption on both inner and outer conductor, in response to the applied voltage above and below the multipactor breakdown level, are obtained to investigate the exact mechanism of multipactor discharge in coaxial lines. Furthermore, the multipactor threshold predictions of the presented model are compared with experimental results using measured secondary emission yield of the tested samples which shows reasonable agreement. Finally, the detailed impact scenario reveals that single-surface multipactor is more likely to occur with a higher outer to inner conductor radius ratio.« less
MT data inversion and sensitivity analysis to image electrical structure of Zagros collision zone
NASA Astrophysics Data System (ADS)
Layegh Haghighi, T.; Montahaei, M.; Oskooi, B.
2018-01-01
Magnetotelluric (MT) data from 46 stations on a 470-km-long profile across the Zagros fold-thrust belt (ZFTB) that marks the Arabia-Eurasia collision zone were inverted to derive 2-D electrical resistivity structure between Busher on the coast of Persian Gulf and Posht-e-Badam, 160 km north east of Yazd. The model includes prominent anomalies in the upper and lower crust, beneath the brittle-ductile transition depth and mostly related to the fluid distribution and sedimentary layers beneath the profile. The conductivities and dimensions of the fault zone conductors (FZCs) and high conductivity zones (HCZs) as the major conductive anomalies in a fault zone conceptual model vary significantly below the different faults accommodated in this region. The enhanced conductivity below the site Z30 correlates well with the main Zagros thrust (MZT), located at the western boundary of Sanandaj-Sirjan zone (SSZ) and known as the transition between the two continents. The depth extent of the huge conductor beneath the south west of the profile, attributed to the thick sedimentary columns of the Arabian crust, cannot be resolved due to the smearing effect of the smoothness constraint employed in the regularized inversion procedure and the sensitivity of MT data to the conductance of the subsurface. We performed different tests to determine the range of 2-D models consistent with the data. Our approach was based on synthetic studies, comprising of hypothesis testing and the use of a priori information throughout the inversion procedure as well as forward modeling. We conclude that the minimum depth extent of the conductive layer beneath the southwest of the profile can be determined as approximately deeper than 15 km and also the screening effect of the conductive overburden is highly intense in this model and prevents the deep structures from being resolved properly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jakobtorweihen, S., E-mail: jakobtorweihen@tuhh.de; Ingram, T.; Gerlach, T.
2014-07-28
Quantitative predictions of biomembrane/water partition coefficients are important, as they are a key property in pharmaceutical applications and toxicological studies. Molecular dynamics (MD) simulations are used to calculate free energy profiles for different solutes in lipid bilayers. How to calculate partition coefficients from these profiles is discussed in detail and different definitions of partition coefficients are compared. Importantly, it is shown that the calculated coefficients are in quantitative agreement with experimental results. Furthermore, we compare free energy profiles from MD simulations to profiles obtained by the recent method COSMOmic, which is an extension of the conductor-like screening model for realisticmore » solvation to micelles and biomembranes. The free energy profiles from these molecular methods are in good agreement. Additionally, solute orientations calculated with MD and COSMOmic are compared and again a good agreement is found. Four different solutes are investigated in detail: 4-ethylphenol, propanol, 5-phenylvaleric acid, and dibenz[a,h]anthracene, whereby the latter belongs to the class of polycyclic aromatic hydrocarbons. The convergence of the free energy profiles from biased MD simulations is discussed and the results are shown to be comparable to equilibrium MD simulations. For 5-phenylvaleric acid the influence of the carboxyl group dihedral angle on free energy profiles is analyzed with MD simulations.« less
Prediction of solubilities for ginger bioactive compounds in hot water by the COSMO-RS method
NASA Astrophysics Data System (ADS)
Zaimah Syed Jaapar, Syaripah; Azian Morad, Noor; Iwai, Yoshio
2013-04-01
The solubilities in water of four main ginger bioactives, 6-gingerol, 6-shogaol, 8-gingerol and 10-gingerol, were predicted using a conductor-like screening model for real solvent (COSMO-RS) calculations. This study was conducted since no experimental data are available for ginger bioactive solubilities in hot water. The σ-profiles of these selected molecules were calculated using Gaussian software and the solubilities were calculated using the COSMO-RS method. The solubilities of these ginger bioactives were calculated at 50 to 200 °C. In order to validate the accuracy of the COSMO-RS method, the solubilities of five hydrocarbon molecules were calculated using the COSMO-RS method and compared with the experimental data in the literature. The selected hydrocarbon molecules were 3-pentanone, 1-hexanol, benzene, 3-methylphenol and 2-hydroxy-5-methylbenzaldehyde. The calculated results of the hydrocarbon molecules are in good agreement with the data in the literature. These results confirm that the solubilities of ginger bioactives can be predicted using the COSMO-RS method. The solubilities of the ginger bioactives are lower than 0.0001 at temperatures lower than 130 °C. At 130 to 200 °C, the solubilities increase dramatically with the highest being 6-shogaol, which is 0.00037 mole fraction, and the lowest is 10-gingerol, which is 0.000039 mole fraction at 200 °C.
Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires
NASA Astrophysics Data System (ADS)
Yao, Shanshan; Zhu, Yong
2014-01-01
Considerable efforts have been made to achieve highly sensitive and wearable sensors that can simultaneously detect multiple stimuli such as stretch, pressure, temperature or touch. Here we develop highly stretchable multifunctional sensors that can detect strain (up to 50%), pressure (up to ~1.2 MPa) and finger touch with high sensitivity, fast response time (~40 ms) and good pressure mapping function. The reported sensors utilize the capacitive sensing mechanism, where silver nanowires are used as electrodes (conductors) and Ecoflex is used as a dielectric. The silver nanowire electrodes are screen printed. Our sensors have been demonstrated for several wearable applications including monitoring thumb movement, sensing the strain of the knee joint in patellar reflex (knee-jerk) and other human motions such as walking, running and jumping from squatting, illustrating the potential utilities of such sensors in robotic systems, prosthetics, healthcare and flexible touch panels.Considerable efforts have been made to achieve highly sensitive and wearable sensors that can simultaneously detect multiple stimuli such as stretch, pressure, temperature or touch. Here we develop highly stretchable multifunctional sensors that can detect strain (up to 50%), pressure (up to ~1.2 MPa) and finger touch with high sensitivity, fast response time (~40 ms) and good pressure mapping function. The reported sensors utilize the capacitive sensing mechanism, where silver nanowires are used as electrodes (conductors) and Ecoflex is used as a dielectric. The silver nanowire electrodes are screen printed. Our sensors have been demonstrated for several wearable applications including monitoring thumb movement, sensing the strain of the knee joint in patellar reflex (knee-jerk) and other human motions such as walking, running and jumping from squatting, illustrating the potential utilities of such sensors in robotic systems, prosthetics, healthcare and flexible touch panels. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr05496a
NASA Astrophysics Data System (ADS)
Aizawa, H.; Kuroki, K.; Yasuzuka, S.; Yamada, J.
2012-11-01
We perform a first-principles band calculation for a group of quasi-two-dimensional organic conductors β-(BDA-TTP)2MF6 (M = P, As, Sb and Ta). The ab-initio calculation shows that the density of states is correlated with the bandwidth of the singly occupied (highest) molecular orbital, while it is not necessarily correlated with the unit-cell volume. The direction of the major axis of the cross section of the Fermi surface lies in the Γ-B-direction, which differs from that obtained by the extended Hückel calculation. Then, we construct a tight-binding model which accurately reproduces the ab-initio band structure. The obtained transfer energies give a smaller dimerization than in the extended Hückel band. As to the difference in the anisotropy of the Fermi surface, the transfer energies along the inter-stacking direction are smaller than those obtained in the extended Hückel calculation. Assuming spin-fluctuation-mediated superconductivity, we apply random phase approximation to a two-band Hubbard model. This two-band Hubbard model is composed of the tight-binding model derived from the first-principles band structure and an on-site (intra-molecule) repulsive interaction taken as a variable parameter. The obtained superconducting gap changes sign four times along the Fermi surface like in a d-wave gap, and the nodal direction is different from that obtained in the extended Hückel model. Anion dependence of Tc is qualitatively consistent with the experimental observation.
The Influence of Music Style and Conductor Race on Perceptions of Ensemble and Conductor Performance
ERIC Educational Resources Information Center
Vanweelden, Kimberly; McGee, Isaiah R.
2007-01-01
The purpose of this study was to examine music style and conductor race on perceptions of ensemble and conductor performance. Results found that conductor race and music style significantly affected ratings of ensemble and conductor performance. Evaluators rated a white conductor group higher than a black conductor group conducting the same…
3-D interpretation of short-period magnetotelluric data at Furnas Volcano, Azores Islands
NASA Astrophysics Data System (ADS)
Hogg, C.; Kiyan, D.; Rath, V.; Byrdina, S.; Vandemeulebrouck, J.; Revil, A.; Viveiros, F.; Carmo, R.; Silva, C.; Ferreira, T.
2018-04-01
Accurate geophysical imaging of shallow subsurface features provides crucial constraints on understanding the dynamics of volcanic systems. At Furnas Volcano (Azores), intense circulation of volcanic fluids at depth leading to high CO2 outgassing and flank destabilization poses considerable threat to the local population. Presented is a novel 3-D electrical resistivity model developed from 39 magnetotelluric soundings that images the hydrothermal system of the Furnas Volcano to a depth of 1 km. The resistivity model images two conductive zones, one at 100 m and another at 500 m depth, separated by a resistive layer. The shallow conductor has conductivity less than 1 S m-1, which can be explained by clay mineral surface conduction with a mass fraction of at least 20 per cent smectite. The deeper conductor extends across the majority of the survey area. This deeper conductor is located at depths where smectite is generally replaced by chlorite and we interpret it as aqueous fluids near the boiling point and infer temperatures of at least 240 °C. The less conductive layer found between these conductors is probably steam-dominated, and coincides within the mixed-clay zone found in many volcanic hydrothermal systems.
Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi
2018-02-14
This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.
Tubular screen electrical connection support for solid oxide fuel cells
Tomlins, Gregory W.; Jaszcar, Michael P.
2002-01-01
A solid oxide fuel assembly is made of fuel cells (16, 16', 18, 24, 24', 26), each having an outer interconnection layer (36) and an outer electrode (28), which are disposed next to each other with rolled, porous, hollow, electrically conducting metal mesh conductors (20, 20') between the fuel cells, connecting the fuel cells at least in series along columns (15, 15') and where there are no metal felt connections between any fuel cells.
Temperature limited heater utilizing non-ferromagnetic conductor
Vinegar,; Harold J. , Harris; Kelvin, Christopher [Houston, TX
2012-07-17
A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.
NASA Astrophysics Data System (ADS)
Glowacki, B. A.; Majoros, M.
2009-06-01
Magnetic materials can help to improve the performance of practical superconductors on the macroscale/microscale as magnetic diverters and also on the nanoscale as effective pinning centres. It has been established by numerical modelling that magnetic shielding of the filaments reduces AC losses in self-field conditions due to decoupling of the filaments and, at the same time, it increases the critical current of the composite. This effect is especially beneficial for coated conductors, in which the anisotropic properties of the superconductor are amplified by the conductor architecture. However, ferromagnetic coatings are often chemically incompatible with YBa2Cu3O7 and (Pb,Bi)2Sr2Ca2Cu3O9 conductors, and buffer layers have to be used. In contrast, in MgB2 conductors an iron matrix may remain in direct contact with the superconducting core. The application of superconducting-magnetic heterostructures requires consideration of the thermal and electromagnetic stability of the superconducting materials used. On one hand, magnetic materials reduce the critical current gradient across the individual filaments but, on the other hand, they often reduce the thermal conductivity between the superconducting core and the cryogen, which may cause destruction of the conductor in the event of thermal instability. A possible nanoscale method of improving the critical current density of superconducting conductors is the introduction of sub-micron magnetic pinning centres. However, the volumetric density and chemical compatibility of magnetic inclusions has to be controlled to avoid suppression of the superconducting properties.
NASA Astrophysics Data System (ADS)
Im, Hyeon-Gyun; An, Byeong Wan; Jin, Jungho; Jang, Junho; Park, Young-Geun; Park, Jang-Ung; Bae, Byeong-Soo
2016-02-01
We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband.We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07657a
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campione, Salvatore; Basilio, Lorena I.; Warne, Larry Kevin
Our paper reports on a transmission-line model for calculating the shielding effectiveness of multiple-shield cables with arbitrary terminations. Since the shields are not perfect conductors and apertures in the shields permit external magnetic and electric fields to penetrate into the interior regions of the cable, we use this model to estimate the effects of the outer shield current and voltage (associated with the external excitation and boundary conditions associated with the external conductor) on the inner conductor current and voltage. It is commonly believed that increasing the number of shields of a cable will improve the shielding performance. But thismore » is not always the case, and a cable with multiple shields may perform similar to or worse than a cable with a single shield. Furthermore, we want to shed more light on these situations, which represent the main focus of this paper.« less
Campione, Salvatore; Basilio, Lorena I.; Warne, Larry Kevin; ...
2016-06-25
Our paper reports on a transmission-line model for calculating the shielding effectiveness of multiple-shield cables with arbitrary terminations. Since the shields are not perfect conductors and apertures in the shields permit external magnetic and electric fields to penetrate into the interior regions of the cable, we use this model to estimate the effects of the outer shield current and voltage (associated with the external excitation and boundary conditions associated with the external conductor) on the inner conductor current and voltage. It is commonly believed that increasing the number of shields of a cable will improve the shielding performance. But thismore » is not always the case, and a cable with multiple shields may perform similar to or worse than a cable with a single shield. Furthermore, we want to shed more light on these situations, which represent the main focus of this paper.« less
Golbamaki, Azadi; Golbamaki, Nazanin; Sizochenko, Natalia; Rasulev, Bakhtiyor; Leszczynski, Jerzy; Benfenati, Emilio
2018-06-09
The genetic toxicology of nanomaterials is a crucial toxicology issue and one of the least investigated topics. Substantially, the genotoxicity of metal oxide nanomaterials' data is resulting from in vitro comet assay. Current contributions to the genotoxicity data assessed by the comet assay provide a case-by-case evaluation of different types of metal oxides. The existing inconsistency in the literature regarding the genotoxicity testing data requires intelligent assessment strategies, such as weight of evidence evaluation. Two main tasks were performed in the present study. First, the genotoxicity data from comet assay for 16 noncoated metal oxide nanomaterials with different core composition were collected. An evaluation criterion was applied to establish which of these individual lines of evidence were of sufficient quality and what weight could have been given to them in inferring genotoxic results. The collected data were surveyed on (1) minimum necessary characterization points for nanomaterials and (2) principals of correct comet assay testing for nanomaterials. Second, in this study the genotoxicity effect of metal oxide nanomaterials was investigated by quantitative nanostructure-activity relationship approach. A set of quantum-chemical descriptors was developed for all investigated metal oxide nanomaterials. A classification model based on decision tree was developed for the investigated dataset. Thus, three descriptors were identified as the most responsible factors for genotoxicity effect: heat of formation, molecular weight, and surface area of the oxide cluster based on the conductor-like screening model. Conclusively, the proposed genotoxicity assessment strategy is useful to prioritize the study of the nanomaterials for further risk assessment evaluations.
Multi-Scale Computational Models for Electrical Brain Stimulation
Seo, Hyeon; Jun, Sung C.
2017-01-01
Electrical brain stimulation (EBS) is an appealing method to treat neurological disorders. To achieve optimal stimulation effects and a better understanding of the underlying brain mechanisms, neuroscientists have proposed computational modeling studies for a decade. Recently, multi-scale models that combine a volume conductor head model and multi-compartmental models of cortical neurons have been developed to predict stimulation effects on the macroscopic and microscopic levels more precisely. As the need for better computational models continues to increase, we overview here recent multi-scale modeling studies; we focused on approaches that coupled a simplified or high-resolution volume conductor head model and multi-compartmental models of cortical neurons, and constructed realistic fiber models using diffusion tensor imaging (DTI). Further implications for achieving better precision in estimating cellular responses are discussed. PMID:29123476
Integrated, nonvolatile, high-speed analog random access memory
NASA Technical Reports Server (NTRS)
Katti, Romney R. (Inventor); Wu, Jiin-Chuan (Inventor); Stadler, Henry L. (Inventor)
1994-01-01
This invention provides an integrated, non-volatile, high-speed random access memory. A magnetically switchable ferromagnetic or ferrimagnetic layer is sandwiched between an electrical conductor which provides the ability to magnetize the magnetically switchable layer and a magneto resistive or Hall effect material which allows sensing the magnetic field which emanates from the magnetization of the magnetically switchable layer. By using this integrated three-layer form, the writing process, which is controlled by the conductor, is separated from the storage medium in the magnetic layer and from the readback process which is controlled by the magnetoresistive layer. A circuit for implementing the memory in CMOS or the like is disclosed.
Transducer for downhole drilling components
Hall, David R; Fox, Joe R
2006-05-30
A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. The transmission element may include an annular housing forming a trough, an electrical conductor disposed within the trough, and an MCEI material disposed between the annular housing and the electrical conductor.
Klasmeier, Jörg; Matthies, Michael; Macleod, Matthew; Fenner, Kathrin; Scheringer, Martin; Stroebe, Maximilian; Le Gall, Anne Christine; Mckone, Thomas; Van De Meent, Dik; Wania, Frank
2006-01-01
We propose a multimedia model-based methodology to evaluate whether a chemical substance qualifies as POP-like based on overall persistence (Pov) and potential for long-range transport (LRTP). It relies upon screening chemicals against the Pov and LRTP characteristics of selected reference chemicals with well-established environmental fates. Results indicate that chemicals of high and low concern in terms of persistence and long-range transport can be consistently identified by eight contemporary multimedia models using the proposed methodology. Model results for three hypothetical chemicals illustrate that the model-based classification of chemicals according to Pov and LRTP is not always consistent with the single-media half-life approach proposed by the UNEP Stockholm Convention and thatthe models provide additional insight into the likely long-term hazards associated with chemicals in the environment. We suggest this model-based classification method be adopted as a complement to screening against defined half-life criteria at the initial stages of tiered assessments designed to identify POP-like chemicals and to prioritize further environmental fate studies for new and existing chemicals.
ggCyto: Next Generation Open-Source Visualization Software for Cytometry.
Van, Phu; Jiang, Wenxin; Gottardo, Raphael; Finak, Greg
2018-06-01
Open source software for computational cytometry has gained in popularity over the past few years. Efforts such as FlowCAP, the Lyoplate and Euroflow projects have highlighted the importance of efforts to standardize both experimental and computational aspects of cytometry data analysis. The R/BioConductor platform hosts the largest collection of open source cytometry software covering all aspects of data analysis and providing infrastructure to represent and analyze cytometry data with all relevant experimental, gating, and cell population annotations enabling fully reproducible data analysis. Data visualization frameworks to support this infrastructure have lagged behind. ggCyto is a new open-source BioConductor software package for cytometry data visualization built on ggplot2 that enables ggplot-like functionality with the core BioConductor flow cytometry data structures. Amongst its features are the ability to transform data and axes on-the-fly using cytometry-specific transformations, plot faceting by experimental meta-data variables, and partial matching of channel, marker and cell populations names to the contents of the BioConductor cytometry data structures. We demonstrate the salient features of the package using publicly available cytometry data with complete reproducible examples in a supplementary material vignette. https://bioconductor.org/packages/devel/bioc/html/ggcyto.html. gfinak@fredhutch.org. Supplementary data are available at Bioinformatics online and at http://rglab.org/ggcyto/.
Howe, Andrew J; McKeag, Nicholas A; Wilson, Carol M; Ashfield, Kyle P; Roberts, Michael J
2015-06-01
Implantable cardioverter defibrillator (ICD) lead insulation failure and conductor externalization have been increasingly reported. The 7.8F silicon-insulated Linox SD and Linox S ICD leads (Biotronik, Berlin, Germany) were released in 2006 and 2007, respectively, with an estimated 85,000 implantations worldwide. A 39-year-old female suffered an out-of-hospital ventricular fibrillation (VF) arrest with successful resuscitation. An ICD was implanted utilizing a single coil active fixation Linox(Smart) S lead (Biotronik, Berlin, Germany). A device-triggered alert approximately 3 years after implantation confirmed nonphysiological high rate sensing leading to VF detection. A chest X-ray showed an abnormality of the ICD lead and fluoroscopic screening confirmed conductor externalization proximal to the defibrillator coil. In view of the combined electrical and fluoroscopic abnormalities, urgent lead extraction and replacement were performed. A review of Linox (Biotronik) and Vigila (Sorin Group, Milan, Italy) lead implantations within our center (n = 98) identified 3 additional patients presenting with premature lead failure, 2 associated with nonphysiological sensed events and one associated with a significant decrease in lead impedance. All leads were subsequently removed and replaced. This case provides a striking example of insulation failure affecting the Linox ICD lead and, we believe, is the first to demonstrate conductor externalization manifesting both electrical and fluoroscopic abnormalities. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mardesich, N.
The scope of the contract covers the development and evaluation of forming solar cell collector grid contacts by the MIDFILM process. This is a proprietary process developed by the Ferro Corporation which is a subcontractor for the program. The MIDFILM process attains line resolution characteristics of photoresist methods with processing related to screen printing. The surface to be processed is first coated with a thin layer of photoresist material. Upon exposure to ultraviolet light through a suitable mask, the resist in the non-pattern area cross-links and becomes hard. The unexposed pattern areas remain tacky. The conductor material is applied inmore » the form of a dry mixture of metal and frit particles which adhere to the tacky pattern area. The assemblage is then fired to ash the photopolymer and sinter the fritted conductor powder. Effort was concentrated during this period on the establishment, optimization and identification of problem areas of the MIDFILM process. Progress is reported. (WHK)« less
Metallic oxide switches using thick film technology
NASA Technical Reports Server (NTRS)
Patel, D. N.; Williams, L., Jr.
1974-01-01
Metallic oxide thick film switches were processed on alumina substrates using thick film technology. Vanadium pentoxide in powder form was mixed with other oxides e.g., barium, strontium copper and glass frit, ground to a fine powder. Pastes and screen printable inks were made using commercial conductive vehicles and appropriate thinners. Some switching devices were processed by conventional screen printing and firing of the inks and commercial cermet conductor terminals on 96% alumina substrates while others were made by applying small beads or dots of the pastes between platinum wires. Static, and dynamic volt-ampere, and pulse tests indicate that the switching and self-oscillatory characteristics of these devices could make them useful in memory element, oscillator, and automatic control applications.
Staged anticonvulsant screening for chronic epilepsy.
Berdichevsky, Yevgeny; Saponjian, Yero; Park, Kyung-Il; Roach, Bonnie; Pouliot, Wendy; Lu, Kimberly; Swiercz, Waldemar; Dudek, F Edward; Staley, Kevin J
2016-12-01
Current anticonvulsant screening programs are based on seizures evoked in normal animals. One-third of epileptic patients do not respond to the anticonvulsants discovered with these models. We evaluated a tiered program based on chronic epilepsy and spontaneous seizures, with compounds advancing from high-throughput in vitro models to low-throughput in vivo models. Epileptogenesis in organotypic hippocampal slice cultures was quantified by lactate production and lactate dehydrogenase release into culture media as rapid assays for seizure-like activity and cell death, respectively. Compounds that reduced these biochemical measures were retested with in vitro electrophysiological confirmation (i.e., second stage). The third stage involved crossover testing in the kainate model of chronic epilepsy, with blinded analysis of spontaneous seizures after continuous electrographic recordings. We screened 407 compound-concentration combinations. The cyclooxygenase inhibitor, celecoxib, had no effect on seizures evoked in normal brain tissue but demonstrated robust antiseizure activity in all tested models of chronic epilepsy. The use of organotypic hippocampal cultures, where epileptogenesis occurs on a compressed time scale, and where seizure-like activity and seizure-induced cell death can be easily quantified with biomarker assays, allowed us to circumvent the throughput limitations of in vivo chronic epilepsy models. Ability to rapidly screen compounds in a chronic model of epilepsy allowed us to find an anticonvulsant that would be missed by screening in acute models.
Conductor for a fluid-cooled winding
Kenney, Walter J.
1983-01-01
A conductor and method of making the conductor are provided for use in winding electrical coils which are cooled by a fluid communicating with the conductor. The conductor is cold worked through twisting and reshaping steps to form a generally rectangular cross section conductor having a plurality of helical cooling grooves extending axially of the conductor. The conductor configuration makes it suitable for a wide variety of winding applications and permits the use of simple strip insulation between turns and perforated sheet insulation between layers of the winding.
Semi-flexible gas-insulated transmission line using sandwiched discs for intermittent flexing joints
Kommineni, P.R.
1983-02-15
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by the use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements are formed by sandwiching together, by fusing, a pair of thin hollow discs which are fixedly secured to both the main conductor sections and the conductor hub section. 4 figs.
Larbalestier, David
2018-01-11
There are over 5000 superconducting materials but only about 5 have ever been useful for applications in magnets, while HEP, which has been so vital for the development of superconducting magnet technology has made virtually every magnet out of just one, the simple bcc alloy Nb-Ti with Tc of 9 K and upper critical field ~ 14T (at 2K). Significant demonstrations of the capability of the brittle intermetallic Nb3Sn have shown that fields of more than 15 T can be generated in dipole form. But Nb-Ti and Nb3Sn are staid, conventional superconductors, far from the cutting edge of superconducting science research where cuprates like YBa2Cu3O7-x and Bi2Sr2CaCu2Ox remain at the scientific forefront and in 2008 were joined by the recently discovered Fe-As pnictide superconductors. What could it mean to have materials for magnets with 10 times the Tc of Nb-Ti (90-120 K) and 3 or more times the critical field (100-240 T)? One enormous barrier is that higher Tc so far always means more complexity and a more localized superconducting interaction which is sensitive to local loss of superconductivity. The issue that has made the cuprate high temperature superconductors so hard to apply is that grain boundaries which form a 3D network in any practical wire form, easily acquire degraded superconducting properties. But conductors can now be made with extreme texture so that grain boundaries are minimized. Moreover almost practical conductors of Bi2Sr2CaCu2Ox and YBa2Cu3O7-x are now are in production and in late 2008 we were, at the Magnet Lab, able to make small solenoids operating at high current density in fields of 32 and almost 34 T respectively. Within the HEP community, there is enthusiasm to embrace HTS conductors for new very high field machines that could, like the Muon Collider, use fields of 30-50 T. In my talk I would like to explore the underlying science controlling such potential applications.
A new expression of Ns versus Ef to an accurate control charge model for AlGaAs/GaAs
NASA Astrophysics Data System (ADS)
Bouneb, I.; Kerrour, F.
2016-03-01
Semi-conductor components become the privileged support of information and communication, particularly appreciation to the development of the internet. Today, MOS transistors on silicon dominate largely the semi-conductors market, however the diminution of transistors grid length is not enough to enhance the performances and respect Moore law. Particularly, for broadband telecommunications systems, where faster components are required. For this reason, alternative structures proposed like hetero structures IV-IV or III-V [1] have been.The most effective components in this area (High Electron Mobility Transistor: HEMT) on IIIV substrate. This work investigates an approach for contributing to the development of a numerical model based on physical and numerical modelling of the potential at heterostructure in AlGaAs/GaAs interface. We have developed calculation using projective methods allowed the Hamiltonian integration using Green functions in Schrodinger equation, for a rigorous resolution “self coherent” with Poisson equation. A simple analytical approach for charge-control in quantum well region of an AlGaAs/GaAs HEMT structure was presented. A charge-control equation, accounting for a variable average distance of the 2-DEG from the interface was introduced. Our approach which have aim to obtain ns-Vg characteristics is mainly based on: A new linear expression of Fermi-level variation with two-dimensional electron gas density in high electron mobility and also is mainly based on the notion of effective doping and a new expression of AEc
NASA Astrophysics Data System (ADS)
Jiang, Zhenan; Zhou, Wei; Li, Quan; Yao, Min; Fang, Jin; Amemiya, Naoyuki; Bumby, Chris W.
2018-07-01
Dynamic resistance, which occurs when a HTS coated conductor carries a DC current under an AC magnetic field, can have critical implications for the design of HTS machines. Here, we report measurements of dynamic resistance in a commercially available SuperPower 4 mm-wide YBCO coated conductor, carrying a DC current under an applied AC magnetic field of arbitrary orientation. The reduced DC current, I t/I c0, ranged from 0.01 to 0.9, where I t is the DC current level and I c0 is the self-field critical current of the conductor. The field angle (the angle between the magnetic field and the normal vector of the conductor wide-face) was varied between 0° and 90° at intervals of 10°. We show that the effective width of the conductor under study is ˜12% less than the physical wire width, and we attribute this difference to edge damage of the wire during or after manufacture. We then examine the measured dynamic resistance of this wire under perpendicular applied fields at very low DC current levels. In this regime we find that the threshold field, B th, of the conductor is well described by the nonlinear equation of Mikitik and Brandt. However, this model consistently underestimates the threshold field at higher current levels. As such, the dynamic resistance in a coated conductor under perpendicular magnetic fields is best described using two different equations for each of the low and high DC current regimes, respectively. At low DC currents where I t/I c0 ≤ 0.1, the nonlinear relationship of Mikitik and Brandt provides the closest agreement with experimental data. However, in the higher current regime where I t/I c0 ≥ 0.2, closer agreement is obtained using a simple linear expression which assumes a current-independent penetration field. We further show that for the conductor studied here, the measured dynamic resistance at different field angles is dominated by the perpendicular magnetic field component, with negligible contribution from the parallel component. Our findings now enable the dynamic resistance of a single conductor to be analytically determined for a very wide range of DC currents and at all applied field angles.
NASA Astrophysics Data System (ADS)
Singh, Shailendra; Maurya, Ved P.; Singh, Roshan K.; Srivastava, Shalivahan; Tripathi, Anurag; Adhikari, P. K.
2018-04-01
Greenstone belts are well known for gold occurrences at different regions of the world. The Dhanjori basin in the eastern Singhbhum region shows major characteristics of a rifted greenstone belt. Initially, we conducted 14 audio-magnetotelluric (AMT) measurements for a profile of ˜ 20 km in the frequency range of 1 kHz to 10 Hz over this rather complex geologic environment covering Dhanjori Volcanics (DhV) and Kolhan Group (KG). Subsequently, gravity and magnetic surveys were also conducted over this AMT profile. The purpose of the survey was to identify and map conductive features and to relate them to metallogeny of the area along with the mapping of the basement of Dhanjori basin. The strike analysis showed N30°W strike for DhV for all the frequencies and for sites over KG domain in the frequency range of 100-10 Hz, but for KG domain, the obtained strike in 1 kHz to 100 Hz is N45°E. As the combination of transverse electric (TE), transverse magnetic (TM) and tipper (Tzy) can recover the electrical signature in complex geological environment, we discuss the conductivity model obtained from TE+TM+Tzy only. The inversion was carried for the regional profile with 14 sites and for 7 sites over KG domain. Conductivity model shows two well resolved conductors, one each in KG and Quartz Pebble Conglomerate Dhanjori (QPCD) domains respectively showing common linked concordant features between these regional and KG profiles. The conductors are interpreted as sulfide mineralization linked with QPCD group of rocks which may host gold. These conductors are also horizontally disposed due to the intrusive younger Mayurbhanj Granite. These intrusives correlate well with the gravity modeling as well. The thickness of the Dhanjori basin at the central is about 3.0 km, similar to that from gravity modeling. The conductivity model also indicates the presence of shallow conductors, but could not be resolved due to lack of high frequency data. However, the results from the close-by drill site indicate the presence of shallow sulfide mineralization hosting gold. The deep level conductors delineated from AMT studies are associated with gravity high and low magnetic. ICP-AES results of Dhanjori samples show significant concentration of gold ˜ 5.0 g/t, which is of economic consideration. Thus, it can be inferred that the conductors have evidences of sulfide mineralization which host gold.
46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Equipment safety grounding (bonding) conductors. 111.05... § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must... 110.10-1). (b) Each equipment-grounding conductor (other than a system-grounding conductor) of a cable...
46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Equipment safety grounding (bonding) conductors. 111.05... § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must... 110.10-1). (b) Each equipment-grounding conductor (other than a system-grounding conductor) of a cable...
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, P.R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent. 3 figs.
Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint
Kommineni, Prasad R.
1983-01-25
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent.
Schmidt, Frank [Langenhagen, DE; Allais, Arnaud [Hannover, DE; Mirebeau, Pierre [Villebon sur Yvette, FR; Ganhungu, Francois [Vieux-Reng, FR; Lallouet, Nicolas [Saint Martin Boulogne, FR
2009-10-20
A terminal structure (2) for a superconducting cable (1) is described. It consists of a conductor (2a) and an insulator (2b) that surrounds the conductor (2a), wherein the superconducting cable (1) has a core with a superconducting conductor (5) and a layer of insulation that surrounds the conductor (5), and wherein the core is arranged in such a way that it can move longitudinally in a cryostat. The conductor (2a) of the terminal structure (2) is electrically connected with the superconducting conductor (5) or with a normal conductor (6) that is connected with the superconducting conductor (5) by means of a tubular part (7) made of an electrically conductive material, wherein the superconducting conductor (5) or the normal conductor (6) can slide in the part (7) in the direction of the superconductor.
NASA Astrophysics Data System (ADS)
Wu, Xiangyang; Tan, Yunfei; Fang, Zhen; Jiang, Donghui; Chen, Zhiyou; Chen, Wenge; Kuang, Guangli
2017-10-01
A large cable-in-conduit-conductor (CICC) test facility has been designed and fabricated at the High Magnetic Field Laboratory of the Chinese Academy of Sciences (CHMFL) in order to meet the test requirement of the conductors which are applied to the future fusion reactor. The critical component of the test facility is an 80 kA superconducting transformer which consists of a multi-turn primary coil and a minor-turn secondary coil. As the current source of the conductor samples, the electromagnetic performance of the superconducting transformer determines the stability and safety of the test facility. In this paper, the key factors and parameters, which have much impact on the performance of the transformer, are analyzed in detail. The conceptual design and optimizing principles of the transformer are discussed. An Electromagnetic-Circuit coupled model built in ANSYS Multiphysics is successfully used to investigate the electromagnetic characterization of the transformer under the dynamic operation condition.
Semi-flexible gas-insulated transmission line using electric field stress shields
Cookson, Alan H.; Dale, Steinar J.; Bolin, Philip C.
1982-12-28
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections.
NASA Astrophysics Data System (ADS)
Matsuda, Y.; Nonomura, T.; Kakutani, K.; Kimbara, J.; Osamura, K.; Kusakari, S.; Toyoda, H.
2015-10-01
An electric field screen is a physical device used to exclude pest insects from greenhouses and warehouses to protect crop production and storage. The screen consists of iron insulated conductor wires (ICWs) arrayed in parallel and linked to each other, an electrostatic DC voltage generator used to supply a negative charge to the ICWs, and an earthed stainless net placed on one side of the ICW layer. The ICW was negatively charged to polarize the earthed net to create a positive charge on the ICW side surface, and an electric field formed between the opposite charges of the ICW and earthed net. The current study focused on the ability of the screen to repel insects reaching the screen net. This repulsion was a result of the insect's behaviour, i.e., the insects were deterred from entering the electric field of the screen. In fact, when the screen was negatively charged with the appropriate voltages, the insects placed their antennae inside the screen and then flew away without entering. Obviously, the insects recognized the electric field using their antennae and thereby avoided entering. Using a wide range of insects and spiders belonging to different taxonomic groups, we confirmed that the avoidance response to the electric field was common in these animals.
Conductor and joint test results of JT-60SA CS and EF coils using the NIFS test facility
NASA Astrophysics Data System (ADS)
Obana, Tetsuhiro; Takahata, Kazuya; Hamaguchi, Shinji; Kizu, Kaname; Murakami, Haruyuki; Chikaraishi, Hirotaka; Noguchi, Hiroki; Kobuchi, Takashi; Moriuchi, Sadatomo; Imagawa, Shinsaku; Mito, Toshiyuki; Tsuchiya, Katsuhiko; Natsume, Kyohei; Yoshida, Kiyoshi; Nomoto, Kazuhiro; Kim, Tae-hyun
2016-01-01
In 2007, JAEA and NIFS launched the test project to evaluate the performance of cable-in-conduit (CIC) conductors and conductor joints for the JT-60SA CS and EF coils. In this project, conductor tests for four types of coil conductor and joint tests for seven types of conductor joint have been conducted for the past eight years using the NIFS test facility. As a result, the test project indicated that the CIC conductors and conductor joints fulfill the design requirement for the CS and EF coils. In addition, the NIFS test facility is expected to be utilized as the test facility for the development of a conductor and conductor joint for the purpose of the DEMO nuclear fusion power plant, provided that the required magnetic field strength is within 9 T.
Thermal conductor for high-energy electrochemical cells
Hoffman, Joseph A.; Domroese, Michael K.; Lindeman, David D.; Radewald, Vern E.; Rouillard, Roger; Trice, Jennifer L.
2000-01-01
A thermal conductor for use with an electrochemical energy storage device is disclosed. The thermal conductor is attached to one or both of the anode and cathode contacts of an electrochemical cell. A resilient portion of the conductor varies in height or position to maintain contact between the conductor and an adjacent wall structure of a containment vessel in response to relative movement between the conductor and the wall structure. The thermal conductor conducts current into and out of the electrochemical cell and conducts thermal energy between the electrochemical cell and thermally conductive and electrically resistive material disposed between the conductor and the wall structure. The thermal conductor may be fabricated to include a resilient portion having one of a substantially C-shaped, double C-shaped, Z-shaped, V-shaped, O-shaped, S-shaped, or finger-shaped cross-section. An elastomeric spring element may be configured so as to be captured by the resilient conductor for purposes of enhancing the functionality of the thermal conductor. The spring element may include a protrusion that provides electrical insulation between the spring conductor and a spring conductor of an adjacently disposed electrochemical cell in the presence of relative movement between the cells and the wall structure. The thermal conductor may also be fabricated from a sheet of electrically conductive material and affixed to the contacts of a number of electrochemical cells.
46 CFR 111.05-31 - Grounding conductors for systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Grounding conductors for systems. 111.05-31 Section 111... Grounding conductors for systems. (a) A conductor for grounding a direct-current system must be the larger of: (1) The largest conductor supplying the system; or (2) No. 8 AWG (8.4mm2). (b) A conductor for...
46 CFR 111.05-31 - Grounding conductors for systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Grounding conductors for systems. 111.05-31 Section 111... Grounding conductors for systems. (a) A conductor for grounding a direct-current system must be the larger of: (1) The largest conductor supplying the system; or (2) No. 8 AWG (8.4mm2). (b) A conductor for...
In vitro models may be useful for the rapid toxicological screening of large numbers of chemicals for their potential to produce toxicity. Such screening could facilitate prioritization of resources needed for in vivo toxicity testing towards those chemicals most likely to resul...
Semi-flexible gas-insulated transmission line using electric field stress shields
Cookson, A.H.; Dale, S.J.; Bolin, P.C.
1982-12-28
A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections. 10 figs.
NASA Technical Reports Server (NTRS)
Xie, Yunsong; Fan, Xin; Chen, Yunpeng; Wilson, Jeefrey D.; Simons, Rainee N.; Xiao, John Q.
2013-01-01
We validate through simulation and experiment that artificial magnetic conductors (AMC s) can be well characterized by a transmission line model. The theoretical bandwidth limit of the in-phase reflection can be expressed in terms of the effective RLC parameters from the surface patch and the properties of the substrate. It is found that the existence of effective inductive components will reduce the in-phase reflection bandwidth of the AMC. Furthermore, we propose design strategies to optimize AMC structures with an in-phase reflection bandwidth closer to the theoretical limit.
Simplified risk assessment of noise induced hearing loss by means of 2 spreadsheet models.
Lie, Arve; Engdahl, Bo; Tambs, Kristian
2016-11-18
The objective of this study has been to test 2 spreadsheet models to compare the observed with the expected hearing loss for a Norwegian reference population. The prevalence rates of the Norwegian and the National Institute for Occupational Safety and Health (NIOSH) definitions of hearing outcomes were calculated in terms of sex and age, 20-64 years old, for a screened (with no occupational noise exposure) (N = 18 858) and unscreened (N = 38 333) Norwegian reference population from the Nord-Trøndelag Hearing Loss Study (NTHLS). Based on the prevalence rates, 2 different spreadsheet models were constructed in order to compare the prevalence rates of various groups of workers with the expected rates. The spreadsheets were then tested on 10 different occupational groups with varying degrees of hearing loss as compared to a reference population. Hearing of office workers, train drivers, conductors and teachers differed little from the screened reference values based on the Norwegian and the NIOSH criterion. The construction workers, miners, farmers and military had an impaired hearing and railway maintenance workers and bus drivers had a mildly impaired hearing. The spreadsheet models give a valid assessment of the hearing loss. The use of spreadsheet models to compare hearing in occupational groups with that of a reference population is a simple and quick method. The results are in line with comparable hearing thresholds, and allow for significance testing. The method is believed to be useful for occupational health services in the assessment of risk of noise induced hearing loss (NIHL) and the preventive potential in groups of noise-exposed workers. Int J Occup Med Environ Health 2016;29(6):991-999. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Induction heaters used to heat subsurface formations
Nguyen, Scott Vinh [Houston, TX; Bass, Ronald M [Houston, TX
2012-04-24
A heating system for a subsurface formation includes an elongated electrical conductor located in the subsurface formation. The electrical conductor extends between at least a first electrical contact and a second electrical contact. A ferromagnetic conductor at least partially surrounds and at least partially extends lengthwise around the electrical conductor. The electrical conductor, when energized with time-varying electrical current, induces sufficient electrical current flow in the ferromagnetic conductor such that the ferromagnetic conductor resistively heats to a temperature of at least about 300.degree. C.
Results of Buoyancy-gravity Effects in ITER Cable-in- Conduit Conductor with Dual Channel
NASA Astrophysics Data System (ADS)
Bruzzone, P.; Stepanov, B.; Zanino, R.; Richard, L. Savoldi
2006-04-01
The coolant in the ITER cable-in-conduit conductors (CICC) flows at significant higher speed in the central channel than in the strand bundle region due to the large difference of hydraulic impedance. When energy is deposited in the bundle region, e.g. by ac loss or radiation, the heat removal in vertically oriented dual channel CICC with the coolant flowing downward is affected by the reduced density of helium (buoyancy) in the bundle region, which is arising from the temperature gradient due to poor heat exchange between the two channels. At large deposited power, flow stagnation and back-flow can cause in the strand bundle area a slow temperature runaway eventually leading to quench. A new test campaign of the thermal-hydraulic behavior was carried out in the SULTAN facility on an instrumented section of the ITER Poloidal Field Conductor Insert (PFIS). The buoyancy-gravity effect was investigated using ac loss heating, with ac loss in the cable calibrated in separate runs. The extent of upstream temperature increase was explored over a broad range of mass flow rate and deposited power. The experimental behavior is partly reproduced by numerical simulations. The results from the tests are extrapolated to the likely operating conditions of the ITER Toroidal Field conductor with the inboard leg cooled from top to bottom and heat deposited by nuclear radiation from the burning plasma.
Estimated number of infants detected and missed by critical congenital heart defect screening.
Ailes, Elizabeth C; Gilboa, Suzanne M; Honein, Margaret A; Oster, Matthew E
2015-06-01
In 2011, the US Secretary of Health and Human Services recommended universal screening of newborns for critical congenital heart defects (CCHDs), yet few estimates of the number of infants with CCHDs likely to be detected through universal screening exist. Our objective was to estimate the number of infants with nonsyndromic CCHDs in the United States likely to be detected (true positives) and missed (false negatives) through universal newborn CCHD screening. We developed a simulation model based on estimates of birth prevalence, prenatal diagnosis, late detection, and sensitivity of newborn CCHD screening through pulse oximetry to estimate the number of true-positive and false-negative nonsyndromic cases of the 7 primary and 5 secondary CCHD screening targets identified through screening. We estimated that 875 (95% uncertainty interval [UI]: 705-1060) US infants with nonsyndromic CCHDs, including 470 (95% UI: 360-585) infants with primary CCHD screening targets, will be detected annually through newborn CCHD screening. An additional 880 (UI: 700-1080) false-negative screenings, including 280 (95% UI: 195-385) among primary screening targets, are expected. We estimated that similar numbers of CCHDs would be detected under scenarios comparing "lower" (∼19%) and "higher" (∼41%) than current prenatal detection prevalences. A substantial number of nonsyndromic CCHD cases are likely to be detected through universal CCHD screening; however, an equal number of false-negative screenings, primarily among secondary targets of screening, are likely to occur. Future efforts should document the true impact of CCHD screening in practice. Copyright © 2015 by the American Academy of Pediatrics.
NASA Astrophysics Data System (ADS)
Dondurur, Derman; Sarı, Coşkun
2004-07-01
A FORTRAN 77 computer code is presented that permits the inversion of Slingram electromagnetic anomalies to an optimal conductor model. Damped least-squares inversion algorithm is used to estimate the anomalous body parameters, e.g. depth, dip and surface projection point of the target. Iteration progress is controlled by maximum relative error value and iteration continued until a tolerance value was satisfied, while the modification of Marquardt's parameter is controlled by sum of the squared errors value. In order to form the Jacobian matrix, the partial derivatives of theoretical anomaly expression with respect to the parameters being optimised are calculated by numerical differentiation by using first-order forward finite differences. A theoretical and two field anomalies are inserted to test the accuracy and applicability of the present inversion program. Inversion of the field data indicated that depth and the surface projection point parameters of the conductor are estimated correctly, however, considerable discrepancies appeared on the estimated dip angles. It is therefore concluded that the most important factor resulting in the misfit between observed and calculated data is due to the fact that the theory used for computing Slingram anomalies is valid for only thin conductors and this assumption might have caused incorrect dip estimates in the case of wide conductors.
Method for making conductors for ferrite memory arrays. [from pre-formed metal conductors
NASA Technical Reports Server (NTRS)
Heckler, C. H.; Baba, P. D.; Bhiwandker, N. C. (Inventor)
1974-01-01
The ferrite memory arrays are made from pre-formed metal conductors for the ferrite arrays. The conductors are made by forming a thin sheet of a metallizing paste of metal alloy powder, drying the paste layer, bisque firing the dried sheet at a first temperature, and then punching the conductors from the fired sheet. During the bisque firing, the conductor sheet shrinks to 58 percent of its pre-fired volume and the alloy particles sinter together. The conductors are embedded in ferrite sheet material and finally fired at a second higher temperature during which firing the conductors shrink approximately the same degree as the ferrite material.
Solvent effects on adsorption of CO over CuCl(1 1 1) surface: A density functional theory study
NASA Astrophysics Data System (ADS)
Zhang, Riguang; Ling, Lixia; Wang, Baojun; Huang, Wei
2010-09-01
DFT calculations have been performed to investigate the effect of dielectric responses of the solvent environment on the CO adsorption over CuCl(1 1 1) surface by using COSMO (conductor-like solvent model) model in Dmol 3. Different dielectric constants, including vacuum, liquid paraffin, methylene chloride, methanol and water solution, are considered. The effects of solvent model on the structural parameters, adsorption energies and vibrational frequency of CO adsorption over CuCl(1 1 1) surface have been investigated. The calculation results suggest that solvent effects can improve the stability of CO adsorption and reduce the intensity of C-O bond, which might mean that solvent is in favor of C-O bond activation and improve the reaction activity of oxidative carbonylation in a slurry reactor.
NASA Astrophysics Data System (ADS)
Yagotintsev, K.; Nijhuis, A.
2018-07-01
Two prototype Nb3Sn cable-in-conduit conductors conductors were designed and manufactured for the toroidal field (TF) magnet system of the envisaged European DEMO fusion reactor. The AC loss, contact resistance and mechanical properties of two sample conductors were tested in the Twente Cryogenic Cable Press under cyclic load up to 30 000 cycles. Though both conductors were designed to operate at 82 kA in a background magnetic field of 13.6 T, they reflect different approaches with respect to the magnet winding pack assembly. The first approach is based on react and wind technology while the second is the more common wind and react technology. Each conductor was tested first for AC loss in virgin condition without handling. The impact of Lorentz load during magnet operation was simulated using the cable press. In the press each conductor specimen was subjected to transverse cyclic load up to 30 000 cycles in liquid helium bath at 4.2 K. Here a summary of results for AC loss, contact resistance, conductor deformation, mechanical heat production and conductor stiffness evolution during cycling of the load is presented. Both conductors showed similar mechanical behaviour but quite different AC loss. In comparison with previously tested ITER TF conductors, both DEMO TF conductors possess very low contact resistance resulting in high coupling loss. At the same time, load cycling has limited impact on properties of DEMO TF conductors in comparison with ITER TF conductors.
Breil, Cassandra; Abert Vian, Maryline; Zemb, Thomas; Kunz, Werner; Chemat, Farid
2017-03-27
Bligh and Dyer (B & D) or Folch procedures for the extraction and separation of lipids from microorganisms and biological tissues using chloroform/methanol/water have been used tens of thousands of times and are "gold standards" for the analysis of extracted lipids. Based on the Conductor-like Screening MOdel for realistic Solvatation (COSMO-RS), we select ethanol and ethyl acetate as being potentially suitable for the substitution of methanol and chloroform. We confirm this by performing solid-liquid extraction of yeast ( Yarrowia lipolytica IFP29 ) and subsequent liquid-liquid partition-the two steps of routine extraction. For this purpose, we consider similar points in the ternary phase diagrams of water/methanol/chloroform and water/ethanol/ethyl acetate, both in the monophasic mixtures and in the liquid-liquid miscibility gap. Based on high performance thin-layer chromatography (HPTLC) to obtain the distribution of lipids classes, and gas chromatography coupled with a flame ionisation detector (GC/FID) to obtain fatty acid profiles, this greener solvents pair is found to be almost as effective as the classic methanol-chloroform couple in terms of efficiency and selectivity of lipids and non-lipid material. Moreover, using these bio-sourced solvents as an alternative system is shown to be as effective as the classical system in terms of the yield of lipids extracted from microorganism tissues, independently of their apparent hydrophilicity.
Breil, Cassandra; Abert Vian, Maryline; Zemb, Thomas; Kunz, Werner; Chemat, Farid
2017-01-01
Bligh and Dyer (B & D) or Folch procedures for the extraction and separation of lipids from microorganisms and biological tissues using chloroform/methanol/water have been used tens of thousands of times and are “gold standards” for the analysis of extracted lipids. Based on the Conductor-like Screening MOdel for realistic Solvatation (COSMO-RS), we select ethanol and ethyl acetate as being potentially suitable for the substitution of methanol and chloroform. We confirm this by performing solid–liquid extraction of yeast (Yarrowia lipolytica IFP29) and subsequent liquid–liquid partition—the two steps of routine extraction. For this purpose, we consider similar points in the ternary phase diagrams of water/methanol/chloroform and water/ethanol/ethyl acetate, both in the monophasic mixtures and in the liquid–liquid miscibility gap. Based on high performance thin-layer chromatography (HPTLC) to obtain the distribution of lipids classes, and gas chromatography coupled with a flame ionisation detector (GC/FID) to obtain fatty acid profiles, this greener solvents pair is found to be almost as effective as the classic methanol–chloroform couple in terms of efficiency and selectivity of lipids and non-lipid material. Moreover, using these bio-sourced solvents as an alternative system is shown to be as effective as the classical system in terms of the yield of lipids extracted from microorganism tissues, independently of their apparent hydrophilicity. PMID:28346372
NASA Astrophysics Data System (ADS)
Tamer, Ömer; Tamer, Sevil Arabacı; İdil, Önder; Avcı, Davut; Vural, Hatice; Atalay, Yusuf
2018-01-01
In this paper, pyridine- 2- carboxylic acid, also known as picolinic acid (pic), and its two derivate, 4- methoxy-pyridine- 2- carboxylic acid (4-Mpic) and 4- chloro-pyridine- 2- carboxylic acid (4-Clpic) have been characterized by FT-IR and UV-Vis spectroscopy techniques as well as DFT calculations. B3LYP level of Density Functional Theory (DFT) method was used to obtain ground state geometries, vibration wavenumbers, first order hyperpolarizabilities and molecular electrostatic potential (MEP) surfaces for pic, 4Clpic and 4Mpic. The electronic absorption wavelengths and HOMO-LUMO energies were investigated by time dependent B3LYP (TD-B3LYP) level with the conductor-like polarizable continuum model (CPCM). The effects of Cl atom and OCH3 group on HOMO-LUMO energy gaps and first order hyperpolarizability parameters of pic, 4Clpic and 4Mpic molecules were examined. All molecules were screened for their antibacterial activities against Gram-positive and Gram-negative bacteria and for their antifungal activities against yeast strains by using minimal inhibitory concentration method (MIC). All compounds (pic, 4Mpic and 4Clpic) have been found to be very active against to the Gram (+) and Gram (-) bacteria. The DNA interactions of pic, 4Clpic and 4Mpic were analyzed by molecular docking simulations, and the interaction of the 4Mpic molecule with DNA is found to be higher than 4Clpic and pic.
NASA Astrophysics Data System (ADS)
Folsom, M.; Pepin, J.; Person, M. A.; Kelley, S.; Peacock, J.
2016-12-01
Twelve magnetotelluric (MT) soundings were collected along a 40 km profile crossing the Rio Grande rift and a portion of the Socorro Magma Body (SMB). A comparison of 1D, 2D and 3D inverse models highlight the strengths and weaknesses of the respective methods. 2D inversion results are distorted by the 3D nature of the data at longer periods, producing conductive artifacts at depths greater than 3 km. We demonstrate through a 3D forward modelling exercise how it is possible to recreate this effect by placing large resistive and conductive features off of an otherwise perfectly 2D resistivity model. Investigators that image deep conductors using 2D inversion codes should consider the influence of off-axis 3D features. Interpretation of the models currently show no indication of the SMB, but outlines the geometry of syn-rift and pre-rift sediments at the "Socorro Constriction", the southern terminus of the Albuquerque Basin. A strong, northward trending conductor 2-3 km deep and less than 2 ohm-m is coincident with the rift, creating a reversal of induction arrow direction at this point. This is interpreted as deep basin brines, perhaps influenced by evaporates hosted in the Permian Abo and Yeso formations. It has been noted that Rio Grande salinity increases in a stepwise manner, coincident with the terminal ends of sedimentary basins. Our geophysical models suggest a possible connection between rift-bounding faults and deep sedimentary brines, which likely impact the water quality of the Rio Grande. Future work includes adding additional MT stations to better constrain off-axis features and their relationship to the Rio Grande.
NASA Astrophysics Data System (ADS)
Šouc, J.; Vojenčiak, M.; Gömöry, F.
2010-04-01
Several short cable models were constructed from YBCO coated conductor (YBCO CC) to study their basic dc and ac electrical properties. They were prepared using superconducting tapes helically wound on fiberglass former of different diameter (5, 8 and 10 mm) with different twist pitch (from 1.7 up to 2.4 cm). The number of parallel-connected tapes ranged from 1 up to 6. The standard length of the models was 11 cm. In one case a 35 cm long model has been manufactured in order to perform a bending test. We observed that the critical currents of the models were proportional to the number of tapes used for their construction. Transport and magnetization ac loss were measured at 36 and 72 Hz.
Testing of the 3M Company Composite Conductor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, John P; Rizy, D Tom; Kisner, Roger A
2010-10-01
The 3M Company has developed a high-temperature low-sag conductor referred to as Aluminum-Conductor Composite-Reinforced or ACCR. The conductor uses an aluminum metal matrix material to replace the steel in conventional conductors. The objective of this work is to accelerate the commercial acceptance by electric utilities of this new conductor design by testing four representative conductor classes in controlled conditions. A unique facility called the Powerline Conductor Accelerated Testing (PCAT) Facility was built at ORNL for testing overhead conductors. The PCAT has been uniquely designed for testing overhead bare transmission line conductors at high currents and temperatures after they have beenmore » installed and tensioned to the manufacturer's specifications. The ability to operate a transmission line conductor in this manner does not exist elsewhere in the United States. Four classes of ACCR cable designed by the 3M Company have been successfully test at ORNL small, medium, large and small/compact. Based on these and other manufacturer tests, the 3M Company has successfully introduced the ACCR into the commercial market and has completed over twenty installations for utility companies.« less
Pluripotent stem cell derived hepatocyte like cells and their potential in toxicity screening.
Greenhough, Sebastian; Medine, Claire N; Hay, David C
2010-12-30
Despite considerable progress in modelling human liver toxicity, the requirement still exists for efficient, predictive and cost effective in vitro models to reduce attrition during drug development. Thousands of compounds fail in this process, with hepatotoxicity being one of the significant causes of failure. The cost of clinical studies is substantial, therefore it is essential that toxicological screening is performed early on in the drug development process. Human hepatocytes represent the gold standard model for evaluating drug toxicity, but are a limited resource. Current alternative models are based on immortalised cell lines and animal tissue, but these are limited by poor function, exhibit species variability and show instability in culture. Pluripotent stem cells are an attractive alternative as they are capable of self-renewal and differentiation to all three germ layers, and thereby represent a potentially inexhaustible source of somatic cells. The differentiation of human embryonic stem cells and induced pluripotent stem cells to functional hepatocyte like cells has recently been reported. Further development of this technology could lead to the scalable production of hepatocyte like cells for liver toxicity screening and clinical therapies. Additionally, induced pluripotent stem cell derived hepatocyte like cells may permit in vitro modelling of gene polymorphisms and genetic diseases. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Im, Hyeon-Gyun; An, Byeong Wan; Jin, Jungho; Jang, Junho; Park, Young-Geun; Park, Jang-Ung; Bae, Byeong-Soo
2016-02-21
We report a high-performance, flexible and robust metal nanotrough-embedded transparent conducting hybrid film (metal nanotrough-GFRHybrimer). Using an electro-spun polymer nanofiber web as a template and vacuum-deposited gold as a conductor, a junction resistance-free continuous metal nanotrough network is formed. Subsequently, the metal nanotrough is embedded on the surface of a glass-fabric reinforced composite substrate (GFRHybrimer). The monolithic composite structure of our transparent conducting film allows simultaneously high thermal stability (24 h at 250 °C in air), a smooth surface topography (Rrms < 1 nm) and excellent opto-electrical properties. A flexible touch screen panel (TSP) is fabricated using the transparent conducting films. The flexible TSP device stably operates on the back of a human hand and on a wristband.
30 CFR Appendix I to Subpart D of... - Appendix I to Subpart D of Part 18
Code of Federal Regulations, 2011 CFR
2011-07-01
... diameter of three-conductor portable power cables with tolerances in inches—601 to 5,000 volts. 8 Fuse... diameters. Table 1—Portable Power Cable Ampacities—600 Volts (Amperes Per Conductor Based on 60 °C. Copper Temperature—40 °C. Ambient) Conductor size—AWG or MCM Single conductor 2-conductor, round or flat 3-conductor...
30 CFR Appendix I to Subpart D of... - Appendix I to Subpart D of Part 18
Code of Federal Regulations, 2010 CFR
2010-07-01
... diameter of three-conductor portable power cables with tolerances in inches—601 to 5,000 volts. 8 Fuse... diameters. Table 1—Portable Power Cable Ampacities—600 Volts (Amperes Per Conductor Based on 60 °C. Copper Temperature—40 °C. Ambient) Conductor size—AWG or MCM Single conductor 2-conductor, round or flat 3-conductor...
NASA Astrophysics Data System (ADS)
Roslan, M. F.; Shaffiar, N. M.; Khairusshima, M. K. N.; Sharifah, I. S. S.
2018-01-01
Over the years, the technology of electronic industry has growth tremendously. Open ended research on how to make a better concept of electronic circuit is ongoing especially on the stretchable electronic devices. There are many designs to achieve stretchability in electronic circuits. The problem occurs when deformation applied to the stretchable electronic circuit, it cannot maintain its functionality. Fracture may happen on the conductor. In this research, the study on deformation of stretchable electronic interconnects substrate using Polydimethlysiloxanes is carried out. The purpose of this research are to study the axial deformation occur, to determine the optimum shape of the conductor designs (horseshoe, rectangular and u-shape design) for the stretchable electronic interconnect and to compare the mechanical properties of Polydimethlysiloxanes (PDMS) with Polyurethane (PU) using Finite Element Analysis (FEA). The simulation was done on the FE model of the stretchable circuit with dimension of 2.4 X 2.4 X 0.5 mm. The stretching of the FE model was simulated with the range of elongation at 10, 20 and 30 percent from its original length in order to find the strain value for all three of the conductor designs. The best conductor design is used to simulate with different types of substrate (PDMS and PU). From the simulation result, Horseshoe design record the lowest strain value for each elongation, followed by rectangular and U-shape design. Thus, Horseshoe is considered as the optimum design for the conductor compared to the other two designs. From the result also, it shows that PDMS substrate will offer more maximum allowable stretchability compared to PU substrates. Thus PDMS is considered as a better substrate compare to PU. PDMS is a good material to replace PU since it can perform under tension much better mechanically.
24 CFR 3280.802 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-04-01
... which, by insertion in a receptacle, establishes connection between the conductors of the attached... and the capacity to conduct safely any current likely to be imposed. (6) Branch circuit (i) means the... predetermined overload of current without injury to itself when properly applied within its rating. (9...
Ceramic electrical insulation for electrical coils, transformers, and magnets
Rice, John A.; Hazelton, Craig S.; Fabian, Paul E.
2002-01-01
A high temperature electrical insulation is described, which is suitable for electrical windings for any number of applications. The inventive insulation comprises a cured preceramic polymer resin, which is preferably a polysiloxane resin. A method for insulating electrical windings, which are intended for use in high temperature environments, such as superconductors and the like, advantageously comprises the steps of, first, applying a preceramic polymer layer to a conductor core, to function as an insulation layer, and second, curing the preceramic polymer layer. The conductor core preferably comprises a metallic wire, which may be wound into a coil. In the preferred method, the applying step comprises a step of wrapping the conductor core with a sleeve or tape of glass or ceramic fabric which has been impregnated by a preceramic polymer resin. The inventive insulation system allows conducting coils and magnets to be fabricated using existing processing equipment, and maximizes the mechanical and thermal performance at both elevated and cryogenic temperatures. It also permits co-processing of the wire and the insulation to increase production efficiencies and reduce overall costs, while still remarkably enhancing performance.
What did we learn from Riata™?
Fischer, Avi; Jenney, C
2015-06-01
The Riata™ 8 French (Fr) and Riata ST™ 7 Fr families of silicone leads have experienced a specific form of insulation abrasion characterized by externalization of conductor cables outside the lead body. Design differences between the 8 Fr and 7 Fr leads make conductor externalization less likely in the smaller diameter lead. The Riata Lead Evaluation Study (RLES) reported on the prevalence of externalized conductors (EC) in patients implanted with Riata™ and Riata ST™ silicone leads and provided details on the incidence of electrical abnormalities in Riata™ and Riata ST™ leads with and without EC. The prevalence of EC was significantly lower for the Riata ST™ leads (7 Fr) as compared with Riata™ leads (8 Fr) (24/259 (9.3 %) vs. 125/517 (24.2 %), P < 0.001), and the majority of leads with EC were not associated with electrical malfunction. The aim of this manuscript is to describe the design of the Riata™ and Riata ST™ families of leads, provide details regarding the mechanisms and rates of lead failure, and discuss recommendations for patient management.
Design of a Wireless Sensor Module for Monitoring Conductor Galloping of Transmission Lines.
Huang, Xinbo; Zhao, Long; Chen, Guimin
2016-10-09
Conductor galloping may cause flashovers and even tower collapses. The available conductor galloping monitoring methods often employ acceleration sensors to measure the conductor translations without considering the conductor twist. In this paper, a new sensor for monitoring conductor galloping of transmission lines based on an inertial measurement unit and wireless communication is proposed. An inertial measurement unit is used for collecting the accelerations and angular rates of a conductor, which are further transformed into the corresponding geographic coordinate frame using a quaternion transformation to reconstruct the galloping of the conductor. Both the hardware design and the software design are described in details. The corresponding test platforms are established, and the experiments show the feasibility and accuracy of the proposed monitoring sensor. The field operation of the proposed sensor in a conductor spanning 734 m also shows its effectiveness.
30 CFR 57.12011 - High-potential electrical conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-potential electrical conductors. 57.12011... Electricity Surface and Underground § 57.12011 High-potential electrical conductors. High-potential electrical conductors shall be covered, insulated, or placed to prevent contact with low potential conductors. ...
33 CFR 183.445 - Conductors: Protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Conductors: Protection. 183.445 Section 183.445 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Conductors: Protection. (a) Each conductor or group of conductors that passes through a bulkhead, structural...
33 CFR 183.445 - Conductors: Protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Conductors: Protection. 183.445 Section 183.445 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Conductors: Protection. (a) Each conductor or group of conductors that passes through a bulkhead, structural...
33 CFR 159.71 - Electrical controls and conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conductors. 159.71 Section 159.71 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Electrical controls and conductors. Electrical controls and conductors must be installed in accordance with good marine practice. Wire must be copper and must be stranded. Electrical controls and conductors must...
30 CFR 57.12004 - Electrical conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electrical conductors. 57.12004 Section 57... Surface and Underground § 57.12004 Electrical conductors. Electrical conductors shall be of a sufficient... operations will not damage the insulating materials. Electrical conductors exposed to mechanical damage shall...
33 CFR 159.71 - Electrical controls and conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conductors. 159.71 Section 159.71 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Electrical controls and conductors. Electrical controls and conductors must be installed in accordance with good marine practice. Wire must be copper and must be stranded. Electrical controls and conductors must...
30 CFR 57.12011 - High-potential electrical conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false High-potential electrical conductors. 57.12011... Electricity Surface and Underground § 57.12011 High-potential electrical conductors. High-potential electrical conductors shall be covered, insulated, or placed to prevent contact with low potential conductors. ...
30 CFR 57.12004 - Electrical conductors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical conductors. 57.12004 Section 57... Surface and Underground § 57.12004 Electrical conductors. Electrical conductors shall be of a sufficient... operations will not damage the insulating materials. Electrical conductors exposed to mechanical damage shall...
30 CFR 57.12004 - Electrical conductors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical conductors. 57.12004 Section 57... Surface and Underground § 57.12004 Electrical conductors. Electrical conductors shall be of a sufficient... operations will not damage the insulating materials. Electrical conductors exposed to mechanical damage shall...
Yanagisawa, Y; Piao, R; Iguchi, S; Nakagome, H; Takao, T; Kominato, K; Hamada, M; Matsumoto, S; Suematsu, H; Jin, X; Takahashi, M; Yamazaki, T; Maeda, H
2014-12-01
High-temperature superconductors (HTS) are the key technology to achieve super-high magnetic field nuclear magnetic resonance (NMR) spectrometers with an operating frequency far beyond 1GHz (23.5T). (RE)Ba 2 Cu 3 O 7- x (REBCO, RE: rare earth) conductors have an advantage over Bi 2 Sr 2 Ca 2 Cu 3 O 10- x (Bi-2223) and Bi 2 Sr 2 CaCu 2 O 8- x (Bi-2212) conductors in that they have very high tensile strengths and tolerate strong electromagnetic hoop stress, thereby having the potential to act as an ultra-compact super-high field NMR magnet. As a first step, we developed the world's first NMR magnet comprising an inner REBCO coil and outer low-temperature superconducting (LTS) coils. The magnet was successfully charged without degradation and mainly operated at 400MHz (9.39T). Technical problems for the NMR magnet due to screening current in the REBCO coil were clarified and solved as follows: (i) A remarkable temporal drift of the central magnetic field was suppressed by a current sweep reversal method utilizing ∼10% of the peak current. (ii) A Z2 field error harmonic of the main coil cannot be compensated by an outer correction coil and therefore an additional ferromagnetic shim was used. (iii) Large tesseral harmonics emerged that could not be corrected by cryoshim coils. Due to those harmonics, the resolution and sensitivity of NMR spectra are ten-fold lower than those for a conventional LTS NMR magnet. As a result, a HSQC spectrum could be achieved for a protein sample, while a NOESY spectrum could not be obtained. An ultra-compact 1.2GHz NMR magnet could be realized if we effectively take advantage of REBCO conductors, although this will require further research to suppress the effect of the screening current. Copyright © 2014 Elsevier Inc. All rights reserved.
Design, development, fabrication and testing of high temperature Flat Conductor Cable (FCC)
NASA Technical Reports Server (NTRS)
Rigling, W. S.
1974-01-01
The results are presented of a development program for a flat, 25-conductor signal cable and a flat, 3-conductor power cable. Flat cables employ conductors made of strips or flattened round copper conductors insulated with polyimide films. It is shown that conductor thickness ranges from 0.003 to 0.010 inch, and begins to soften and loose mechanical strength at temperatures above 200 C.
NASA Astrophysics Data System (ADS)
Sancarlos-González, Abel; Pineda-Sanchez, Manuel; Puche-Panadero, Ruben; Sapena-Bano, Angel; Riera-Guasp, Martin; Martinez-Roman, Javier; Perez-Cruz, Juan; Roger-Folch, Jose
2017-12-01
AC lines of industrial busbar systems are usually built using conductors with rectangular cross sections, where each phase can have several parallel conductors to carry high currents. The current density in a rectangular conductor, under sinusoidal conditions, is not uniform. It depends on the frequency, on the conductor shape, and on the distance between conductors, due to the skin effect and to proximity effects. Contrary to circular conductors, there are not closed analytical formulas for obtaining the frequency-dependent impedance of conductors with rectangular cross-section. It is necessary to resort to numerical simulations to obtain the resistance and the inductance of the phases, one for each desired frequency and also for each distance between the phases' conductors. On the contrary, the use of the parametric proper generalized decomposition (PGD) allows to obtain the frequency-dependent impedance of an AC line for a wide range of frequencies and distances between the phases' conductors by solving a single simulation in a 4D domain (spatial coordinates x and y, the frequency and the separation between conductors). In this way, a general "virtual chart" solution is obtained, which contains the solution for any frequency and for any separation of the conductors, and stores it in a compact separated representations form, which can be easily embedded on a more general software for the design of electrical installations. The approach presented in this work for rectangular conductors can be easily extended to conductors with an arbitrary shape.
24 CFR 3280.815 - Polarization.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) The identified (white) conductor shall be employed for grounding circuit conductors only and shall be... unswitched wire in switched circuits, except that a cable containing an identified conductor (white) shall be... unidentified conductor is the return conductor from the switch to the outlet. Painting of the terminal end of...
46 CFR 169.683 - Overcurrent protection, general.
Code of Federal Regulations, 2011 CFR
2011-10-01
... provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation... ungrounded conductors of the circuit simultaneously. (c) Each conductor, including a generator lead and shore...
24 CFR 3280.815 - Polarization.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) The identified (white) conductor shall be employed for grounding circuit conductors only and shall be... unswitched wire in switched circuits, except that a cable containing an identified conductor (white) shall be... unidentified conductor is the return conductor from the switch to the outlet. Painting of the terminal end of...
Correlation between cation conduction and ionic morphology in a PEO-based single ion conductor
NASA Astrophysics Data System (ADS)
Lin, Kan-Ju; Maranas, Janna
2011-03-01
We use molecular dynamics simulation to study ion transport and backbone mobility of a PEO-based single ion conductor. Ion mobility depends on the chemical structure and the local environment of the ions, which consequently impact ionic conductivity. We characterize the aggregation state of the ions, and assess the role of ion complexes in ionomer dynamics. In addition to solvated cations and pairs, higher order ion clusters are found. Most of the ion clusters are in string-like structure and cross-link two or more different ionomer chains through ionic binding. Ionic crosslinks decrease mobility at the ionic co-monomer; hence the mobility of the adjacent PEO segment is influenced. Na ions show slow mobility when they are inside large clusters. The hopping timescale for Na varies from 20 ns to 200. A correlation is found between Na mobility and the number of hops from one coordination site to another. Besides ether oxygens, Na ions in the ionomer also use the anion and the edge of the cluster as hopping sites. The string-like structure of clusters provide less stable sites at the two ends thus ions are more mobile in those regions. We observed Grotthus like mechanism in our ionomer, in which the positive charge migrates within the string-like cluster without the cations actually moving.
NASA Astrophysics Data System (ADS)
Stewart, Ian Edward
Printed electronics, including transparent conductors, currently rely on expensive materials to generate high conductivity devices. Conductive inks for thick film applications utilizing inkjet, aerosol, and screen printing technologies are often comprised of expensive and rare silver particles. Thin film applications such as organic light emitting diodes (OLEDs) and organic photovoltaics (OPVs) predominantly employ indium tin oxide (ITO) as the transparent conductive layer which requires expensive and wasteful vapor deposition techniques. Thus an alternative to silver and ITO with similar performance in printed electronics warrants considerable attention. Copper nanomaterials, being orders of magnitude cheaper and more abundant than silver or indium, solution-coatable, and exhibiting a bulk conductivity only 6 % less than silver, have emerged as a promising candidate for incorporation in printed electronics. First, we examine the effect of nanomaterial shape on the conductivity of thick films. The inks used in such films often require annealing at elevated temperature in order to sinter the silver nanoparticles together and obtain low resistivities. We explore the change in morphology and resistivity that occurs upon heating thick films of silver nanowires (of two different lengths, Ag NWs), nanoparticles (Ag NPs), and microflakes (Ag MFs) deposited from water at temperatures between 70 and 400 °C. At the lowest temperatures, longer Ag NWs exhibited the lowest resistivity (1.8 x 10-5 O cm), suggesting that the resistivity of thick films of silver nanostructures is dominated by the contact resistance between particles. This result supported previous research showing that junction resistance between Ag NWs in thin film conductors also dominates optoelectronic performance. Since the goal is to replace silver with copper, we perform a similar analysis by using a pseudo-2D rod network modeling approach that has been modified to include lognormal distributions in length that more closely reflect experimental data collected from the nanowire transparent conductors. In our analysis, we find that Cu NW-based transparent conductors are capable of achieving comparable electrical performance to Ag NW transparent conductors with similar dimensions. We also synthesize high aspect ratio Cu NWs (as high as 5700 in an aqueous based synthesis taking less than 30 minutes) and show that this increase in aspect ratio can result results in transparent conducting films with a transmittance >95% at a sheet resistance <100 O sq-1, optoelectronic properties similar to that for ITO. Two of the major barriers preventing the further use of Cu NWs in printed electronics are the necessity to anneal the nanowires under H2 at higher temperatures and copper's susceptibility to oxidation. The former issue is solved by removing the insulating oxide along the Cu NWs with acetic acid and pressing the nanowires together to make H2 annealing obsolete. Finally, several methods of preventing copper oxidation in the context of transparent conductors were successfully developed such as electroplating zinc, tin, and indium and electrolessly plating benzotriazole (BTAH), nickel, silver, gold, and platinum. While all of the shells lessened or prevented oxidation both in dry and humid conditions, it was found that a thin layer of silver confers identical optoelectronic properties to the Cu NWs as pure Ag NWs. These results are expected provide motivation to replace pure silver and ITO in printed electronics.
Preliminary fabrication and characterization of low-leakage hybrid coaxial cable
NASA Astrophysics Data System (ADS)
Rudnitsky, Arkady; Elbaz, David; Zalevsky, Zeev
2013-10-01
In this paper we present the fabrication and the initial characterization of a new type of coaxial cable having reduced leakage characteristics and the capability of transmitting optical signals, in additional to the RF signal, through the glass medium between the metallic conductors. The suggested decreased leakage and material loss is obtained by using different metallic shield geometry. The suggested model is composed of a central conductor surrounded by plurality of metallic wires circularly disposed.
Varenyk, O. V.; Silibin, M. V.; Kiselev, Dmitri A.; ...
2015-08-19
The frequency dependent Electrochemical Strain Microscopy (ESM) response of mixed ionic-electronic conductors is analyzed within the framework of Fermi-Dirac statistics and the Vegard law, accounting for steric effects from mobile donors. The emergence of dynamic charge waves and nonlinear deformation of the surface in response to bias applied to the tip-surface junction is numerically explored. The 2D maps of the strain and concentration distributions across the mixed ionic-electronic conductor and bias-induced surface displacements are calculated. Furthermore, the obtained numerical results can be applied to quantify the ESM response of Li-based solid electrolytes, materials with resistive switching, and electroactive ferroelectric polymers,more » which are of potential interest for flexible and high-density non-volatile memory devices.« less
NASA Astrophysics Data System (ADS)
Varenyk, O. V.; Silibin, M. V.; Kiselev, D. A.; Eliseev, E. A.; Kalinin, S. V.; Morozovska, A. N.
2015-08-01
The frequency dependent Electrochemical Strain Microscopy (ESM) response of mixed ionic-electronic conductors is analyzed within the framework of Fermi-Dirac statistics and the Vegard law, accounting for steric effects from mobile donors. The emergence of dynamic charge waves and nonlinear deformation of the surface in response to bias applied to the tip-surface junction is numerically explored. The 2D maps of the strain and concentration distributions across the mixed ionic-electronic conductor and bias-induced surface displacements are calculated. The obtained numerical results can be applied to quantify the ESM response of Li-based solid electrolytes, materials with resistive switching, and electroactive ferroelectric polymers, which are of potential interest for flexible and high-density non-volatile memory devices.
30 CFR 56.12005 - Protection of power conductors from mobile equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Protection of power conductors from mobile... MINES Electricity § 56.12005 Protection of power conductors from mobile equipment. Mobile equipment shall not run over power conductors, nor shall loads be dragged over power conductors, unless the...
An Exploratory Comparison of Novice, Intermediate, and Expert Orchestral Conductors
ERIC Educational Resources Information Center
Bergee, Martin J.
2005-01-01
This study compared novice, "intermediate" (graduate student), and expert orchestral conductors. Two novice conductors, one graduate student in orchestral conducting, and one expert conductor led a university symphony orchestra in part of the first movement of Brahms's Symphony No. 2. Wired for sound, conductors attempted to verbalize their…
30 CFR 56.12005 - Protection of power conductors from mobile equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of power conductors from mobile... MINES Electricity § 56.12005 Protection of power conductors from mobile equipment. Mobile equipment shall not run over power conductors, nor shall loads be dragged over power conductors, unless the...
NASA Astrophysics Data System (ADS)
Cordell, Darcy; Unsworth, Martyn J.; Díaz, Daniel
2018-04-01
Magnetotelluric (MT) data were collected at the Laguna del Maule volcanic field (LdMVF), located in central Chile (36°S, 70.5°W), which has been experiencing unprecedented upward ground deformation since 2007. These data were used to create the first detailed three-dimensional electrical resistivity model of the LdMVF and surrounding area. The resulting model was spatially complex with several major conductive features imaged at different depths and locations around Laguna del Maule (LdM). A near-surface conductor (C1; 0.5 Ωm) approximately 100 m beneath the lake is interpreted as a conductive smectite clay cap related to a shallow hydrothermal reservoir. At 4 km depth, a strong conductor (C3; 0.3 Ωm) is located beneath the western edge of LdM. The proximity of C3 to the recent Pleistocene-to-Holocene vents in the northwest LdMVF and nearby hot springs suggests that C3 is a hydrous (>5 wt% H2O), rhyolitic partial melt with melt fraction >35% and a free-water hydrothermal component. C3 dips towards, and is connected to, a deeper conductor (C4; 1 Ωm). C4 is located to the north of LdM at >8 km depth below surface and is interpreted as a long-lived, rhyolitic-to-andesitic magma reservoir with melt fractions less than 35%. It is hypothesized that the deeper magma reservoir (C4) is providing melt and hydrothermal fluids to the shallower magma reservoir (C3). A large conductor directly beneath the LdMVF is not imaged with MT suggesting that any mush volume beneath LdM must be anhydrous (<2 wt% H2O), low temperature and low melt fraction (<25%) in order to go undetected. The presence of large conductors to the north has important implications for magma dynamics as it suggests that material may have a significant lateral component (>10 km) as it moves from the deep magma reservoir (C4) to create small, ephemeral volumes of eruptible melt (C3). It is hypothesized that there may be a north-south contrast in physical processes affecting the growth of melt-rich zones since major conductors are imaged in the northern LdMVF while no major conductors are detected beneath the southern vents. The analysis and interpretation of features directly beneath the lake is complicated by the surface conductor C1 which attenuates low-frequency signals. The attenuation from C1 does not affect C3 or C4. At 1 km depth directly beneath LdM, a weak conductor (C2; <10 Ωm) is imaged but is not required by the data. Forward modeling tests show that a relatively large (30 km3), high melt fraction (>50%), silicic reservoir with 5 wt% H2O at 2 to 5 km depth beneath the inflation center is not supported by the MT data. However, a smaller (10 km3) eruptible volume could go undetected even with relatively high melt fraction (>50%). The location of large melt regions to the north has important implications for long-term volcanic hazards at LdMVF as well as other volcanoes as it raises the possibility that the vent distribution is not always indicative of the location of deeper source regions of melt.
Electro-expulsive separation system
NASA Technical Reports Server (NTRS)
Haslim, Leonard A. (Inventor); Lee, Robert D. (Inventor)
1987-01-01
An electro-expulsive system has one or more overlapped conductors, each comprising a flexible ribbon conductor, which is folded back on itself. The conductors are embedded in an elastomeric material. Large current pulses are fed to the conductors from power storage units. As a result of the antiparallel currents, the opposed segments of a conductor are forcefully separated and the elastomeric material is distended. Voids in the elastomer aid the separation of the conductor segments. The distention is almost instantaneous when a current pulse reaches the conductor and the distention tends to remove any solid body on the surface of the elastomeric material.
Multifilamentary niobium tin magnet conductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larbalestier, D.C.; Madsen, P.E.; Lee, J.A.
1975-03-01
Practical magnet conductors of multifilamentary Nb$sub 3$Sn have been produced. Evaluation of these bronze route conductors is described. Conductors studied range from a 1369 filament all-bronze matrix conductor to 5143 and approximately 42,000 filament conductors, containing internal high purity copper protected by diffusion barriers. Filament sizes vary from approximately 3 to 8 $mu$m diameter. The effect of heat treatment conditions on critical current and transition temperature is presented and it is shown that overall critical current densities greater than those available in niobium titanium can now be produced in multifilamentary Nb$sub 3$Sn magnet conductor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caporaso, George J.; Poole, Brian R.; Hawkins, Steven A.
2015-06-30
The devices, systems and techniques disclosed here can be used to reduce undesired effects by magnetic field induced eddy currents based on a diamagnetic composite material structure including diamagnetic composite sheets that are separated from one another to provide a high impedance composite material structure. In some implementations, each diamagnetic composite sheet includes patterned conductor layers are separated by a dielectric material and each patterned conductor layer includes voids and conductor areas. The voids in the patterned conductor layers of each diamagnetic composite sheet are arranged to be displaced in position from one patterned conductor layer to an adjacent patternedmore » conductor layer while conductor areas of the patterned conductor layers collectively form a contiguous conductor structure in each diamagnetic composite sheet to prevent penetration by a magnetic field.« less
NASA Astrophysics Data System (ADS)
Amemiya, Naoyuki; Tominaga, Naoki; Toyomoto, Ryuki; Nishimoto, Takuma; Sogabe, Yusuke; Yamano, Satoshi; Sakamoto, Hisaki
2018-07-01
The shielding-current-induced field is a serious concern for the applications of coated conductors to magnets. The striation of the coated conductor is one of the countermeasures, but it is effective only after the decay of the coupling current, which is characterised with the coupling time constant. In a non-twisted striated coated conductor, the coupling time constant is determined primarily by its length and the transverse resistance between superconductor filaments, because the coupling current could flow along its entire length. We measured and numerically calculated the frequency dependences of magnetisation losses in striated and copper-plated coated conductors with various lengths and their stacks at 77 K and determined their coupling time constants. Stacked conductors simulate the turns of a conductor wound into a pancake coil. Coupling time constants are proportional to the square of the conductor length. Stacking striated coated conductors increases the coupling time constants because the coupling currents in stacked conductors are coupled to one another magnetically to increase the mutual inductances for the coupling current paths. We carried out the numerical electromagnetic field analysis of conductors wound into pancake coils and determined their coupling time constants. They can be explained by the length dependence and mutual coupling effect observed in stacked straight conductors. Even in pancake coils with practical numbers of turns, i.e. conductor lengths, the striation is effective to reduce the shielding-current-induced fields for some dc applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, J.P.; RIzy, D.T.; Kisner, R.A.
The 3M Company has developed a high-temperature low-sag conductor referred to as Aluminum- Conductor Composite-Reinforced or ACCR. The conductor uses an aluminum metal matrix material to replace the steel in conventional conductors so the core has a lower density and higher conductivity. The objective of this work is to accelerate the commercial acceptance by electric utilities of these new conductor designs by testing four representative conductor classes in controlled conditions. Overhead transmission lines use bare aluminum conductor strands wrapped around a steel core strands to transmit electricity. The typical cable is referred to as aluminum-conductor steel-reinforced (ACSR). The outer strandsmore » are aluminum, chosen for its conductivity, low weight, and low cost. The center strand is of steel for the strength required to support the weight without stretching the aluminum due to its ductility. The power density of a transmission corridor has been directly increased by increasing the voltage level. Transmission voltages have increased from 115-kV to 765- kV over the past 80 years. In the United States, further increasing the voltage level is not feasible at this point in time, so in order to further increase the power density of a transmission corridor, conductor designs that increase the current carrying capability have been examined. One of the key limiting factors in the design of a transmission line is the conductor sag which determines the clearance of the conductor above ground or underlying structures needed for electrical safety. Increasing the current carrying capability of a conductor increases the joule heating in the conductor which increases the conductor sag. A conductor designed for high-temperature and lowsag operation requires an engineered modification of the conductor materials. To make an advanced cable, the 3M Company solution has been the development of a composite conductor consisting of Nextel ceramic fibers to replace the steel core and an aluminum-zirconium alloy to improve the outer strands. The result is a cable that can carry more current than steelaluminum lines without sagging as much at higher temperatures. A unique facility called the Powerline Conductor Accelerated Testing (PCAT) Facility was built at ORNL for testing overhead conductors. The PCAT has been uniquely designed for testing overhead bare transmission line conductors at high currents and temperatures after they have been installed and tensioned to the manufacturer's specifications. The ability to operate a transmission line conductor in this manner does not exist elsewhere in the United States. Four classes of ACCR cable designed by 3M have been successfully test at ORNL – small, medium, large and small/compact. Based on these and other manufacturer tests, the 3M Company has successfully introduced the ACCR into the commercial market and has completed over twenty installations for utility companies.« less
The effect of the cation alkyl chain branching on mutual solubilities with water and toxicities.
Kurnia, Kiki A; Sintra, Tânia E; Neves, Catarina M S S; Shimizu, Karina; Canongia Lopes, José N; Gonçalves, Fernando; Ventura, Sónia P M; Freire, Mara G; Santos, Luís M N B F; Coutinho, João A P
2014-10-07
The design of ionic liquids has been focused on the cation-anion combinations but other more subtle approaches can be used. In this work the effect of the branching of the cation alkyl chain on the design of ionic liquids (ILs) is evaluated. The mutual solubilities with water and toxicities of a series of bis(trifluoromethylsulfonyl)-based ILs, combined with imidazolium, pyridinium, pyrrolidinium, and piperidinium cations with linear or branched alkyl chains, are reported. The mutual solubility measurements were carried out in the temperature range from (288.15 to 323.15) K. From the obtained experimental data, the thermodynamic properties of the solution (in the water-rich phase) were determined and discussed. The COnductor like Screening MOdel for Real Solvents (COSMO-RS) was used to predict the liquid-liquid equilibrium. Furthermore, molecular dynamic simulations were also carried out aiming to get a deeper understanding of these fluids at the molecular level. The results show that the increase in the number of atoms at the cation ring (from five to six) leads to a decrease in the mutual solubilities with water while increasing their toxicity, and as expected from the well-established relationship between toxicities and hydrophobicities of ILs. The branching of the alkyl chain was observed to decrease the water solubility in ILs, while increasing the ILs solubility in water. The inability of COSMO-RS to correctly predict the effect of branching alkyl chains toward water solubility on them was confirmed using molecular dynamic simulations to be due to the formation of nano-segregated structures of the ILs that are not taken into account by the COSMO-RS model. In addition, the impact of branched alkyl chains on the toxicity is shown to be not trivial and to depend on the aromatic nature of the ILs.
30 CFR 57.12080 - Bare conductor guards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare conductor guards. 57.12080 Section 57... Underground Only § 57.12080 Bare conductor guards. Trolley wires and bare power conductors shall be guarded at... conductors are less than 7 feet above the rail, they shall be guarded at all points where persons work or...
30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipped with metallic shields around each power conductor with one or more ground conductors having a total cross-sectional area of not less than one-half the power conductor, and with an insulated conductor for the ground continuity check circuit. External ground check conductors may be used if they are...
30 CFR 57.12080 - Bare conductor guards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bare conductor guards. 57.12080 Section 57... Underground Only § 57.12080 Bare conductor guards. Trolley wires and bare power conductors shall be guarded at... conductors are less than 7 feet above the rail, they shall be guarded at all points where persons work or...
Fischer, William H.; Yoon, Kue H.
1984-04-10
A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed perpendicular to the direction of travel of the inner conductor/insulating support assembly.
Polymer thick-film conductors and dielectrics for membrane switches and flexible circuitry
NASA Technical Reports Server (NTRS)
Nazarenko, N.
1983-01-01
The fabrication and operation of membrane switches are discussed. The membrane switch functions as a normally open, momentary contact, low-voltage pressure-sensitive device. Its design is a three-layer sandwich usually constructed of polyester film. Conductive patterns are deposited onto the inner side of top and bottom sheets by silk screening. The center spacer is then placed between the two circuit layers to form a sandwich, generally held together by an adhesive. When pressure is applied to the top layer, it flexes through the punched openings of the spacer to establish electrical contact between conductive pads of the upper and lower sheets, momentarily closing the circuit. Upon release of force the top sheet springs back to its normal open position. The membrane touch switch is being used in a rapidly expanding range of applications, including instrumentation, appliances, electronic games and keyboards. Its board acceptance results from its low cost, durability, ease of manufacture, cosmetic appeal and design flexibility. The principal electronic components in the membrane switch are the conductor and dielectric.
Chen, Judy Ying; Ma, Qiufei; Everhard, Francois; Yermilov, Irina; Tian, Haijun; Mayer, Kenneth Hugh
2011-06-01
The Centers for Disease Control strongly recommends HIV screening for all patients who present to health care settings with sexually transmitted diseases (STD) or blood-borne pathogens exposure. The objective of this study is to assess the rates and determinants of HIV screening in a national sample of commercially insured patients screened or diagnosed with an STD or hepatitis B or C. We used Poisson regression model with a robust error variance to assess the determinants of HIV screening using administrative claims data from health plans across 6 states (n = 270,423). The overall HIV screening rate of patients who were diagnosed or screened for STDs or hepatitis was low (32.7%); rates were lowest for patients presenting with epididymitis or granuloma inguinale (<10%). Patients aged 25 to 34 years were more likely to be screened than other age groups. Females were significantly less likely to be screened for HIV (prevalence ratio = 0.90; 95% CI = 0.89, 0.91) than males. Patients living in states where no written HIV informed consent was required were significantly more likely to be screened than those living in states where written HIV informed consent was specifically required. HIV screening rates were low and varied by STD categories. Females and younger and older patients were at increased risk of no HIV screening. Requiring specific written informed consent for HIV screening resulted in less HIV screening. Interventions are urgently needed to increase the HIV screening rate among this at-risk population.
Lung Cancer Screening May Benefit Those at Highest Risk
People at the highest risk for lung cancer, based on a risk model, may be more likely to benefit from screening with low-dose CT, a new analysis suggests. The study authors believe the findings may better define who should undergo lung cancer screening, as this Cancer Currents blog post explains.
Nanoscale electromechanical parametric amplifier
Aleman, Benjamin Jose; Zettl, Alexander
2016-09-20
This disclosure provides systems, methods, and apparatus related to a parametric amplifier. In one aspect, a device includes an electron source electrode, a counter electrode, and a pumping electrode. The electron source electrode may include a conductive base and a flexible conductor. The flexible conductor may have a first end and a second end, with the second end of the flexible conductor being coupled to the conductive base. A cross-sectional dimension of the flexible conductor may be less than about 100 nanometers. The counter electrode may be disposed proximate the first end of the flexible conductor and spaced a first distance from the first end of the flexible conductor. The pumping electrode may be disposed proximate a length of the flexible conductor and spaced a second distance from the flexible conductor.
Wireless tamper detection sensor and sensing system
NASA Technical Reports Server (NTRS)
Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)
2011-01-01
A wireless tamper detection sensor is defined by a perforated electrical conductor. The conductor is shaped to form a geometric pattern between first and second ends thereof such that the conductor defines an open-circuit that can store and transfer electrical and magnetic energy. The conductor resonates in the presence of a time-varying magnetic field to generate a harmonic response. The harmonic response changes when the conductor experiences a change in its geometric pattern due to severing of the conductor along at least a portion of the perforations. A magnetic field response recorder is used to wirelessly transmit the time-varying magnetic field and wirelessly detecting the conductor's harmonic response.
Plasma Generator Using Spiral Conductors
NASA Technical Reports Server (NTRS)
Szatkowski, George N. (Inventor); Dudley, Kenneth L. (Inventor); Ticatch, Larry A. (Inventor); Smith, Laura J. (Inventor); Koppen, Sandra V. (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor)
2016-01-01
A plasma generator includes a pair of identical spiraled electrical conductors separated by dielectric material. Both spiraled conductors have inductance and capacitance wherein, in the presence of a time-varying electromagnetic field, the spiraled conductors resonate to generate a harmonic electromagnetic field response. The spiraled conductors lie in parallel planes and partially overlap one another in a direction perpendicular to the parallel planes. The geometric centers of the spiraled conductors define endpoints of a line that is non-perpendicular with respect to the parallel planes. A voltage source coupled across the spiraled conductors applies a voltage sufficient to generate a plasma in at least a portion of the dielectric material.
NASA Astrophysics Data System (ADS)
Das, Suprem R.; Sadeque, Sajia; Jeong, Changwook; Chen, Ruiyi; Alam, Muhammad A.; Janes, David B.
2016-06-01
Although transparent conductive oxides such as indium tin oxide (ITO) are widely employed as transparent conducting electrodes (TCEs) for applications such as touch screens and displays, new nanostructured TCEs are of interest for future applications, including emerging transparent and flexible electronics. A number of twodimensional networks of nanostructured elements have been reported, including metallic nanowire networks consisting of silver nanowires, metallic carbon nanotubes (m-CNTs), copper nanowires or gold nanowires, and metallic mesh structures. In these single-component systems, it has generally been difficult to achieve sheet resistances that are comparable to ITO at a given broadband optical transparency. A relatively new third category of TCEs consisting of networks of 1D-1D and 1D-2D nanocomposites (such as silver nanowires and CNTs, silver nanowires and polycrystalline graphene, silver nanowires and reduced graphene oxide) have demonstrated TCE performance comparable to, or better than, ITO. In such hybrid networks, copercolation between the two components can lead to relatively low sheet resistances at nanowire densities corresponding to high optical transmittance. This review provides an overview of reported hybrid networks, including a comparison of the performance regimes achievable with those of ITO and single-component nanostructured networks. The performance is compared to that expected from bulk thin films and analyzed in terms of the copercolation model. In addition, performance characteristics relevant for flexible and transparent applications are discussed. The new TCEs are promising, but significant work must be done to ensure earth abundance, stability, and reliability so that they can eventually replace traditional ITO-based transparent conductors.
Modification of the Mathematical Model of the Thermoelectric Module of a Thermostating Coating
NASA Astrophysics Data System (ADS)
Zarubin, V. S.; Kuvyrkin, G. N.; Savel'eva, I. Yu.
2017-03-01
A modification has been made of the previously constructed mathematical model of a fragment of a flat thermostating coating including a thermoelectric module based on the variation formulation of the stationary problem of heat conduction in an inhomogeneous solid body. With the use of the Fourier finite integral transform the dependences have been obtained for calculating the temperature distribution in the heat insulating layer in the vicinity of the thermoelectric element and commutating conductors. This enabled us to refine one of the diagnostic variables of the model — the total heat resistance of the heat insulator between commutating plates and conductors of the thermoelectric module influencing the energy characteristics of the thermostating coating under investigation.
Lau, Ernest W
2013-01-01
The mathematical modelling of column buckling or beam bending under an axial or transverse load is well established. However, the existent models generally assume a high degree of symmetry in the structure of the column and minor longitudinal and transverse displacements. The situation when the column is made of several components with different mechanical properties asymmetrically distributed in the transverse section, semi-rigid, and subjected to multiple axial loads with significant longitudinal and transverse displacements through compression and bending has not been well characterised. A more comprehensive theoretical model allowing for these possibilities and assuming a circular arc contour for the bend is developed, and used to establish the bending axes, balance between compression and bending, and equivalent stiffness of the column. In certain situations, such as with pull cable catheters commonly used for minimally invasive surgical procedures, the compression loads are applied via cables running through channels inside a semi-rigid column. The model predicts the mathematical relationships between the radius of curvature of the bend and the tension in and normal force exerted by such cables. Conjugate extension with reciprocal compression-bending is a special structural arrangement for a semi-rigid column such that extension of one segment is linked to compression-bending of another by inextensible cables running between them. Leads are cords containing insulated electrical conductor coil and cables between the heart muscle and cardiac implantable electronic devices. Leads can behave like pull cable catheters through differential component pulling, providing a possible mechanism for inside-out abrasion and conductor cable externalisation. Certain design features may predispose to this mode of structural failure. Copyright © 2012 Elsevier Ltd. All rights reserved.
Leatherdale, S T; Ahmed, R
2011-09-01
To determine the percentage of Canadian youth meeting screen-time guidelines and to identify characteristics associated with different screen-time behaviours. Using nationally representative data collected from the 2008/2009 Youth Smoking Survey (YSS), we analyzed three screen-time behaviours, cigarette smoking, weekly spending money, self esteem, region and grade by sex, and conducted four logistic regression models to examine factors associated with more than 2 hours a day of sedentary screen time. Of 51 922 Canadian youth in grades 6 to 12, 50.9% spent more than 2 hours per day in screen-based behaviours. The average daily screen time was 7.8 (± 2.3) hours. Males and current smokers were more likely to report over 2 hours per day watching TV and videos or playing video games, whereas students in higher grades and those with weekly spending money were more likely to report playing or surfing on a computer. Youth with higher self-esteem were less likely to report spending over 2 hours per day in each of the three screen-time behaviours examined. Developing a better understanding of the factors associated with more hours of screen time is required to develop and target interventions that reduce screen-time behaviours.
46 CFR 111.60-4 - Minimum cable conductor size.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...
46 CFR 111.60-4 - Minimum cable conductor size.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
campione, Salvatore; Warne, Larry K.; Schiek, Richard
This report details the modeling results for the response of a finite-length dissipative conductor interacting with a conducting ground to the Bell Labs electromagnetic pulse excitation. We use both a frequency-domain and a time-domain method based on transmission line theory through a code we call ATLOG - Analytic Transmission Line Over Ground. Results are compared to the circuit simulator Xyce for selected cases. Intentionally Left Blank
DOE Office of Scientific and Technical Information (OSTI.GOV)
campione, Salvatore; Warne, Larry K.; Schiek, Richard
2017-09-01
This report details the modeling results for the response of a finite-length dissipative conductor interacting with a conducting ground to a hypothetical nuclear device with the same output energy spectrum as the Fat Man device. We use a frequency-domain method based on transmission line theory and implemented it in a code we call ATLOG - Analytic Transmission Line Over Ground. Select results are compared to ones computed using the circuit simulator Xyce. Intentionally Left Blank
29 CFR 1926.404 - Wiring design and protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Portable and mobile X-ray and associated equipment; (4) Tools likely to be used in wet and/or conductive...) The noncurrent-carrying metal parts of equipment and the equipment grounding conductor terminals of... receptacles mounted on the vehicle or on the generator, and (C) The noncurrent-carrying metal parts of...
29 CFR 1926.404 - Wiring design and protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Portable and mobile X-ray and associated equipment; (4) Tools likely to be used in wet and/or conductive...) The noncurrent-carrying metal parts of equipment and the equipment grounding conductor terminals of... receptacles mounted on the vehicle or on the generator, and (C) The noncurrent-carrying metal parts of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stelzer, Gerald; Meinke, Rainer; Senti, Mark
A conductor assembly and method for constructing an assembly of the type which, when conducting current, generates a magnetic field or which, in the presence of a changing magnetic field, induces a voltage. In one embodiment the method provides a first insulative layer tubular in shape and including a surface along which a conductor segment may be positioned. A channel formed in the surface of the insulative layer defines a first conductor path and includes a surface of first contour in cross section along a first plane transverse to the conductor path. A segment of conductor having a surface ofmore » second contour in cross section is positioned at least partly in the channel and extends along the conductor path. Along the first plane, contact between the conductor surface of second contour and the channel surface of first contour includes at least two separate regions of contact.« less
System providing limit switch function with simultaneous absolute position output
NASA Technical Reports Server (NTRS)
Alhorn, Dean C. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)
2006-01-01
A limit and position sensing system includes a sensor assembly and an emitter. The sensor assembly includes first and second electrical conductors arranged in opposing parallel planes. The first electrical conductor is coiled outwardly from either end thereof in a clockwise fashion to form a first coil region and a second coil region. The second electrical conductor forms a single coil with portions of the single coil's rings lying between the first end and second end of the first electrical conductor being parallel to an axis of the first electrical conductor's plane. Ferromagnetic material is aligned with the first and second electrical conductors and spans beyond (a) the first and second ends of the first electrical conductor, and (b) the portions of the rings of the second electrical conductor's single coil that lie between the first end and second end of the first electrical conductor. The emitter is spaced apart from the sensor assembly and transmits a periodic electromagnetic wave towards the sensor assembly.
Rhodes, Mark A.
2008-10-21
A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.
Advanced CerMet ceramic composites for medical applications.
Dittmer, Robert; Schaefer, Christian M; Fischer, Jean-Francois; Hausch, Ulrich; Troetzschel, Jens; Specht, Heiko
2017-11-01
Implantable active devices such as pacemakers are facing rigorous requirements. Because they reside within the body for years, materials applied in this surrounding must exhibit biocompatibility and extraordinary reliability. They also have to provide a number of functional properties. In this work we present a method that enables the realization of a highly complex profile of properties by means of a dual composite approach. Using multilayer technology, an electrical conductor is embedded into a ceramic matrix, thus, creating conductive paths that are insulated from each other. In addition to this macroscopically hybrid architecture, this approach features a second composite aspect: the conductor is not composed of a single metallic phase, but is a ceramic-metal mixture. Owing to its interpenetrating microstructure, this CerMet allows for a strong and hermetic integration of the conductor into the ceramic matrix otherwise impossible due to mismatch in thermal expansion. In fact, the CerMet ceramic composite exhibits a higher strength than the pure ceramic as revealed by a three-point bending test study. At the same time, the CerMet offers high and virtually metal-like conductor properties, enabling a down-scaling of the conductive paths to 150µm diameter and smaller. Furthermore, the described composite is biocompatible, non-magnetic, and chemically inert, which is vital for the application in active, implantable, medical devices. Beside the general fabrication route, we present the microstructural, functional, and mechanical properties of this newly developed class of dual composites. Copyright © 2017 Elsevier Ltd. All rights reserved.
Electromechanical properties of superconductors for DOE fusion applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekin, J.W.; Moreland, J.; Brauch, J.C.
1986-03-01
This is an interim report presenting data on superconductor performance under mechanical load, which are needed for the selection of superconductors and the mechanical design of superconducting magnets for DOE fusion energy systems. A further aim of the reported research is to measure and understand the electromechanical properties of promising new superconductor materials with strong application potential at high magnetic fields. Results include the following. The first strain vs. critical-current studies were made on a Chevrel-phase superconductor, PbMo/sub 6/S/sub 8/. Chevrel-phase superconductors were found to have a large strain effect, comparable in magnitude to A-15 superconductors like Nb/sub 3/Sn. Electromechanical-propertymore » measurements of an experimental liquid-tin-infiltrated Nb/sub 3/Sn conductor showed it to have an irreversible strain limit twice as large as bronze-process supercondutors and a significantly higher overall critical-current denstiy; the liquid-infiltration process thus has the potential for development of a practical Nb/sub 3/Sn conductors with both superior critical-current density and extremely good mechanical properties. Electromechanical parameters were obtained on several Nb/sub 3/Sn conductors that are candidate materials for superconducting fusion magnets, icluding conductors fabricated by the bronze, internal-tin, and jelly-roll processes. Thermal contraction data are reported on several new structural materials for superconductor sheathing and reinforcement, and a new diagnostic tool for probing the energy gap of practical superconductors has been developed using electron tunneling.« less
James, Monique; Thomas, Melanie; Frolov, Latoya; Riano, Nicholas S; Vittinghoff, Eric; Schillinger, Dean; Newcomer, John W; Mangurian, Christina
2017-08-01
This study aimed to determine cervical cancer screening rates among women with severe mental illness. California Medicaid administrative records (2010-2011) for 31,308 women with severe mental illness were examined. Participants received specialty mental health services and were not dually eligible for Medicare. Poisson models assessed association between selected predictors and cervical cancer screening. Overall, 20.2% of women with severe mental illness received cervical cancer screening during the one-year period. Compared with white women, Asian women (adjusted risk ratio [ARR]=1.23), black women (ARR=1.10), and Hispanic women (ARR=1.11) (p<.001) were more likely to have been screened. Women ages 28-37 were more likely than those ages 18-27 to have been screened (ARR=1.31, p<.001). Evidence of other health care use was the strongest predictor of screening (ARR=3.07, p<.001). Most women in the sample were not regularly screened for cervical cancer. Cervical cancer screening for this high-risk population should be prioritized.
Push-pull radio frequency circuit with integral transistion to waveguide output
Bennett, Wilfred P.
1987-01-01
A radio frequency circuit for ICRF heating includes a resonant push-pull circuit, a double ridged rectangular waveguide, and a coupling transition which joins the waveguide to the resonant circuit. The resonant circuit includes two cylindrical conductors mounted side by side and two power vacuum tubes attached to respective ends of a cylindrical conductor. A conductive yoke is located at the other end of the cylindrical conductors to short circuit the two cylindrical conductors. The coupling transition includes two relatively flat rectangular conductors extending perpendicular to the longitudinal axes of a respective cylindrical conductor to which the flat conductor is attached intermediate the ends thereof. Conductive side covers and end covers are also provided for forming pockets in the waveguide into which the flat conductors extend when the waveguide is attached to a shielding enclosure surrounding the resonant circuit.
Activation barriers for methylation of DNA bases by dimethyl sulfate
NASA Astrophysics Data System (ADS)
Eichler, Daniel R.; Papadantonakis, George A.
2017-12-01
The SN2 transition states of the methylation reaction of DNA bases with dimethyl sulfate were examined employing DFT/ M06-2X/6-31+G∗ and DFT/B3LYP-D3/6-311+G (2df, 2p) levels of theory. Solvation effects were examined using the conductor-like polarizable continuum model (CPCM). Calculation results and feedback from electrostatic potential maps show that in water, charge separation lowers the activation barriers relative to the gas phase for the reactions at N7 of guanine, N3 of adenine and cytosine. Also, the reaction at the O6 site of guanine is governed by steric interference and exhibits a higher activation barrier in water.
NASA Astrophysics Data System (ADS)
Reddy B., Venkata P.; Mukherjee, Subhajit; Mitra, Ishani; Moi, Sankar Ch.
2017-12-01
Heptaplatin is an approved platinum based cytostatic drug for the treatment of gastric cancers. The hydrolytic bio-transformation of Heptaplatin and the platination processes of guanine (G) and adenine (A) with resulting mono and di-aquated species of Heptaplatin have been investigated using density functional theory (DFT) combined with the conductor like dielectric continuum model (CPCM) approach, to spotlight the drug activation energy profiles and their binding mechanisms. The stationary points on the potential energy surfaces were fully optimized and characterized. The mono-functional binding of Heptaplatin, guanine as target over adenine due to electronic factors and more favorable hydrogen-bonds pattern.
Analytical study of nano-scale logical operations
NASA Astrophysics Data System (ADS)
Patra, Moumita; Maiti, Santanu K.
2018-07-01
A complete analytical prescription is given to perform three basic (OR, AND, NOT) and two universal (NAND, NOR) logic gates at nano-scale level using simple tailor made geometries. Two different geometries, ring-like and chain-like, are taken into account where in each case the bridging conductor is coupled to a local atomic site through a dangling bond whose site energy can be controlled by means of external gate electrode. The main idea is that when injecting electron energy matches with site energy of local atomic site transmission probability drops exactly to zero, whereas the junction exhibits finite transmission for other energies. Utilizing this prescription we perform logical operations, and, we strongly believe that the proposed results can be verified in laboratory. Finally, we numerically compute two-terminal transmission probability considering general models and the numerical results match exactly well with our analytical findings.
33 CFR 183.435 - Conductors in circuits of 50 volts or more.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Conductors in circuits of 50... Requirements § 183.435 Conductors in circuits of 50 volts or more. (a) Each conductor in a circuit that has a... nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable...
33 CFR 183.435 - Conductors in circuits of 50 volts or more.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Conductors in circuits of 50... Requirements § 183.435 Conductors in circuits of 50 volts or more. (a) Each conductor in a circuit that has a... nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable...
33 CFR 183.435 - Conductors in circuits of 50 volts or more.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Conductors in circuits of 50... Requirements § 183.435 Conductors in circuits of 50 volts or more. (a) Each conductor in a circuit that has a... nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable...
33 CFR 183.435 - Conductors in circuits of 50 volts or more.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Conductors in circuits of 50... Requirements § 183.435 Conductors in circuits of 50 volts or more. (a) Each conductor in a circuit that has a... nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable...
33 CFR 183.435 - Conductors in circuits of 50 volts or more.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Conductors in circuits of 50... Requirements § 183.435 Conductors in circuits of 50 volts or more. (a) Each conductor in a circuit that has a... nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable...
Fischer, William H.
1984-01-01
A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a non-binding transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement and for moving without binding along corrugations of any slope less than vertical. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed parallel to the motion of travel of the inner conductor/insulating support assembly.
Foster, Jr., John S.; Wilson, James R.; McDonald, Jr., Charles A.
1983-01-01
1. In an electrical energy generator, the combination comprising a first elongated annular electrical current conductor having at least one bare surface extending longitudinally and facing radially inwards therein, a second elongated annular electrical current conductor disposed coaxially within said first conductor and having an outer bare surface area extending longitudinally and facing said bare surface of said first conductor, the contiguous coaxial areas of said first and second conductors defining an inductive element, means for applying an electrical current to at least one of said conductors for generating a magnetic field encompassing said inductive element, and explosive charge means disposed concentrically with respect to said conductors including at least the area of said inductive element, said explosive charge means including means disposed to initiate an explosive wave front in said explosive advancing longitudinally along said inductive element, said wave front being effective to progressively deform at least one of said conductors to bring said bare surfaces thereof into electrically conductive contact to progressively reduce the inductance of the inductive element defined by said conductors and transferring explosive energy to said magnetic field effective to generate an electrical potential between undeformed portions of said conductors ahead of said explosive wave front.
Ono, Kentaro; Nakamura, Akinori; Maess, Burkhard
2015-01-01
For orchestra musicians, synchronized playing under a conductor's direction is necessary to achieve optimal performance. Previous studies using simple auditory/visual stimuli have reported cortico-subcortical networks underlying synchronization and that training improves the accuracy of synchronization. However, it is unclear whether people who played regularly under a conductor and non-musicians activate the same networks when synchronizing with a conductor's gestures. We conducted a functional magnetic resonance imaging (fMRI) experiment testing nonmusicians and musicians who regularly play music under a conductor. Participants were required to tap the rhythm they perceived from silent movies displaying either conductor's gestures or a swinging metronome. Musicians performed tapping under a conductor with more precision than nonmusicians. Results from fMRI measurement showed greater activity in the anterior part of the left superior frontal gyrus (SFG) in musicians with more frequent practice under a conductor. Conversely, tapping with the metronome did not show any difference between musicians and nonmusicians, indicating that the expertize effect in tapping under the conductor does not result in a general increase in tapping performance for musicians. These results suggest that orchestra musicians have developed an advanced ability to predict conductor's next action from the gestures.
NASA Technical Reports Server (NTRS)
Koga, J. K.; Lin, C. S.; Winglee, R. M.
1989-01-01
Injections of nonrelativistic electron beams from an isolated equipotential conductor into a uniform background of plasma and neutral gas were simulated using a 2-D electrostatic particle code. The ionization effects on spacecraft charging are examined by including interactions of electrons with neutral gas. The simulations show that the conductor charging potential decreases with increasing neutral background density due to the production of secondary electrons near the conductor surface. In the spacecraft wake, the background electrons accelerated towards the charged spacecraft produce an enhancement of secondary electrons and ions. Simulations run for longer times indicate that the spacecraft potential is further reduced and short wavelength beam-plasma oscillations appear. The results are applied to explain the spacecraft charging potential measured during the SEPAC experiments from Spacelab 1.
Electric/magnetic field sensor
Schill, Jr., Robert A.; Popek, Marc [Las Vegas, NV
2009-01-27
A UNLV novel electric/magnetic dot sensor includes a loop of conductor having two ends to the loop, a first end and a second end; the first end of the conductor seamlessly secured to a first conductor within a first sheath; the second end of the conductor seamlessly secured to a second conductor within a second sheath; and the first sheath and the second sheath positioned adjacent each other. The UNLV novel sensor can be made by removing outer layers in a segment of coaxial cable, leaving a continuous link of essentially uncovered conductor between two coaxial cable legs.
Conductor-polymer composite electrode materials
Ginley, D.S.; Kurtz, S.R.; Smyrl, W.H.; Zeigler, J.M.
1984-06-13
A conductive composite material useful as an electrode, comprises a conductor and an organic polymer which is reversibly electrochemically dopable to change its electrical conductivity. Said polymer continuously surrounds the conductor in intimate electrical contact therewith and is prepared by electrochemical growth on said conductor or by reaction of its corresponding monomer(s) on said conductor which has been pre-impregnated or pre-coated with an activator for said polymerization. Amount of the conductor is sufficient to render the resultant composite electrically conductive even when the polymer is in an undoped insulating state.
Flat conductor cable design, manufacture, and installation
NASA Technical Reports Server (NTRS)
Angele, W.; Hankins, J. D.
1973-01-01
Pertinent information for hardware selection, design, manufacture, and quality control necessary for flat conductor cable interconnecting harness application is presented. Comparisons are made between round wire cable and flat conductor cable. The flat conductor cable interconnecting harness systems show major cost, weight, and space savings, plus increased system performance and reliability. The design application section includes electrical characteristics, harness design and development, and a full treatise on EMC considerations. Manufacturing and quality control sections pertain primarily to the developed conductor-contact connector system and special flat conductor cable to round wire cable transitions.
Miniature intermittent contact switch
NASA Technical Reports Server (NTRS)
Sword, A.
1972-01-01
Design of electric switch for providing intermittent contact is presented. Switch consists of flexible conductor surrounding, but separated from, fixed conductor. Flexing of outside conductor to contact fixed conductor completes circuit. Advantage is small size of switch compared to standard switches.
Reactive conductors for increased efficiency of exploding foil initiators and other detonators
Morris, Christopher J.; Wilkins, Paul; May, Chadd; Zakar, Eugene
2015-05-05
Provided among other things are reactive energetic material systems used for conductors in detonators for increased efficiencies. According to an embodiment, a detonator may include: a conductor including at least two constituents including (i) an electrically conductive constituent, and (ii) an electrically non-conductive constituent, that when subjected to sufficient electrical energy, result in an exothermic reaction; and a flyer plate having a non-conductive surface in contact with said conductor. When the sufficient electrical energy is supplied to said conductor, rapid heating and vaporization of at least a portion of the conductor occurs so as to explosively drive at least a portion of the flyer plate away from said conductor. In an embodiment, a multilayer conductor may be formed of alternating layers of at least one electrically conductive layer, and at least one electrically non-conductive layer, that when subjected to sufficient electrical energy, result in an exothermic reaction.
Hannon, Peggy A.; Escoffery, Cam; Vu, Thuy; Kohn, Marlana; Vernon, Sally W.; DeGroff, Amy
2014-01-01
Introduction Since 2009, the Centers for Disease Control and Prevention (CDC) has awarded nearly $95 million to 29 states and tribes through the Colorectal Cancer Control Program (CRCCP) to fund 2 program components: 1) providing colorectal cancer (CRC) screening to uninsured and underinsured low-income adults and 2) promoting population-wide CRC screening through evidence-based interventions identified in the Guide to Community Preventive Services (Community Guide). CRCCP is a new model for disseminating and promoting use of evidence-based interventions. If the program proves successful, CDC may adopt the model for future cancer control programs. The objective of our study was to compare the colorectal cancer screening practices of recipients of CRCCP funding (grantees) with those of nonrecipients (nongrantees). Methods We conducted parallel Web-based surveys in 2012 with CRCCP grantees (N = 29) and nongrantees (N = 24) to assess promotion and provision of CRC screening, including the use of evidence-based interventions. Results CRCCP grantees were significantly more likely than nongrantees to use Community Guide-recommended evidence-based interventions (mean, 3.14 interventions vs 1.25 interventions, P < .001) and to use patient navigation services (eg, transportion or language translation services) (72% vs 17%, P < .001) for promoting CRC screening. Both groups were equally likely to use other strategies. CRCCP grantees were significantly more likely to provide CRC screening than were nongrantees (100% versus 50%, P < .001). Conclusion Results suggest that CRCCP funding and support increases use of evidence-based interventions to promote CRC screening, indicating the program’s potential to increase population-wide CRC screening rates. PMID:25275807
Vertically aligned gas-insulated transmission line having particle traps at the inner conductor
Dale, Steinar J.
1984-01-01
Gas insulated electrical apparatus having first and second conductors separated by an insulating support within an insulating gas environment, and particle traps disposed along the surface of the high potential conductor for trapping and inactivating foreign particles which may be present within the insulating gas medium. Several embodiments of the invention were developed which are particularly suited for vertically aligned gas insulated transmission lines. The particle traps are grooves or cavities formed into the walls of the tubular inner conductor, without extending into the hollow portion of the conductor. In other embodiments, the traps are appendages or insert flanges extending from the inner conductor, with the insulator supports contacting the appendages instead of the inner conductor.
High-field double-pancake superconducting coils and a method of winding
Materna, P.A.
1984-01-31
A double-pancake coil having first and second pancakes may comprise a plurality of conductor means, each conductor means having a different grade and having one or more conductors, wherein each pancake of said double-pancake coil is comprised of inner and outer turns; wherein said inner turns are comprised of at least one of said conductor means wound about an axis and nested within one another; wherein said outer turns are comprised of said inner conductor means and at least one other conductor means co-wound about said inner turns and nested within one another; wherein each of said conductor means is wound along said axis from said first pancake to said second pancake at a different turn.
High-field double-pancake superconducting coils and a method of winding
Materna, Peter A.
1985-01-01
A double-pancake coil having first and second pancakes may comprise a plurality of conductor means, each conductor means having a different grade and having one or more conductors, wherein each pancake of said double-pancake coil is comprised of inner and outer turns; wherein said inner turns are comprised of at least one of said conductor means wound about an axis and nested within one another; wherein said outer turns are comprised of said inner conductor means and at least one other conductor means co-wound about said inner turns and nested within one another; wherein each of said conductor means is wound along said axis from said first pancake to said second pancake at a different turn.
Modeling of transmission line exposure to direct lightning strokes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizk, F.A.M.
1990-10-01
The paper introduces a new model for assessing the exposure of free-standing structures and horizontal conductors above flat ground to direct lightning strokes. The starting point of this work is a recently developed criterion for positive leader inception, modified to account for positive leaders initiated under the influence of a negative descending lightning stroke. Subsequent propagation of the positive leader is analyzed to define the point of encounter of the two leaders which determines the attractive radius of a structure or the attractive lateral distance of a conductor. These parameters are investigated for a wide range of heights and return-strokemore » currents. A method for analyzing shielding failure and determining the critical shielding angle is also described. The predictions of the model are compared with field observations and previously developed models.« less
30 CFR 56.12010 - Isolation or insulation of communication conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conductors. 56.12010 Section 56.12010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... MINES Electricity § 56.12010 Isolation or insulation of communication conductors. Telephone and low... energized power conductors or any other power source. ...
30 CFR 56.12010 - Isolation or insulation of communication conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conductors. 56.12010 Section 56.12010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... MINES Electricity § 56.12010 Isolation or insulation of communication conductors. Telephone and low... energized power conductors or any other power source. ...
Analyse dynamique des lignes de grande portee sous charges de vent
NASA Astrophysics Data System (ADS)
Ashby, Mathieu
There are two types of electric crossing : i) subterranean / submarine line ii) overhead-line crossing. We always consider the last one as a more economic option. The inconvenience of an overhead-line crossing would be the environmental constraints among which the existing obstacles, the clearance for the navigation and the aesthetics demanded by the public. The overhead-line crossings usually have conductors of long ranges which are outside of the field of application for the current transmission line codes. These are limited to reaches of a length included between 200 m and 800 m, as well as a height of support lower than 60 m. However, for reaches over 800 m and over a height over 60 m, the criteria of conception in the transmission line codes for the calculation of wind loads are not applicable. In this study we concentrate on loads on the supports owed to the limit wind applied to bare conductors and insulators chains The objective of the present study is to examine the effect of the temporal and spatial correlation of the wind load along the conductors on a finite element model. A special attention was brought to the evaluation of the importance of the dynamic load transmitted on by the conductors and the insulators chains for the case of a turbulent wind load. The numerical study on finite element model for the example of a overhead-line crossing was done with the software ADINA. The wind load for the finite element model for the example of a overhead-line crossing was generated by the software WindGen which uses the method of Simiu-Scanlan and the method of spectral representation developed by Shinozuka-Deodatis. Wind loads generated where integrated into the finite element model ADINA for a dynamic analysis of the overhead-line crossing. For the first part, the current methods are used to calculate the efforts in supports due to the wind loads with an engineering approach and a comparaison approach. The current methods are then compared with the efforts obtained from an advanced method, transient dynamic and spectral stochastic, and specifically for the case of a simple overhead-line and an overhead-line crossings. For the second part, the effect of the longitudinal correlation of the wind load on two parallel conductors was examined. Finally, dynamic experiments on an insulators chain were made to determine the variation of the damping and the rigidity of the system for different type of insulators, different speed of application of the load and the inclination of the insulator. Key words : transient dynamics, spectral stochastic, turbulent wind, conductor, aerodynamic damping, structural damping, spatial correlation, wind spectra
Collective phenomena in the early stages of relativistic heavy-ion collisions
NASA Astrophysics Data System (ADS)
Ryblewski, Radoslaw
Geophysical signatures of volcano-hosted geothermal systems in Indonesia are compiled and synthesized. Parameters include electrical resistivity, seismicity, downhole logging, and pressure/temperature data; temperature and pressure states of systems are simulated through numerical models. The systems are Sungai Penuh, Hululais, Lumutbalai, Ulubelu, Kamojang, Kotamobagu, Tompaso, and Lahendong. The general resistivity structure of the systems comprises a vertical conductor under the volcano peak (<10 ohm.m), a lateral conductor under the volcano flank (<10 ohm.m), and an intermediate resistivity zone under the lateral conductor. Background formations are generally resistive with a resistivity >70 ohm.m. The vertical conductor is the expression of either an active or inactive volcanic neck / magmatic chimney. The lateral conductor is the claycap of the geothermal system containing an argillic alteration zone that keeps the hot fluids and the heat inside the reservoir. The topography of the volcano dictates the hydrology and shapes the extent of the lateral conductor. The hydrothermal fluids themselves are kept within the intermediate resistivity region, 10--60 ohm.m for a liquid-dominated system, and up to 100 ohm.m for a vapor-dominated system, preferably with the temperature of 200--300 ° C. On the margins, the reservoir may have either sharp or diffuse contact with the background or the claycap; vapor-dominated systems have a sharp contact. A diffuse contact is usually associated with a gradational change in temperature, with temperature reversal at depth. The caprock of a geothermal system has an aseismic character possibly due to its ductile behavior from the clay and from its low permeability structure. The low permeability property impedes liquid movement and flashing that could induce seismicity. The propylitic reservoir is seismogenic due to less clay content and its high permeability that promotes liquid movement and flashing into steam which induces seismicity. Modeling studies suggest that the most favorable permeability configuration for a vapor-dominated reservoir similar to Kamojang contains a caprock with the permeability of 3 x 10 -16 m2 accompanied with a recharge region/hostrock having the permeability of 10-18 m2 to 10-17 m2. A heat flow of 8 MW/km 2 for 9 kyr is the minimum combination to produce a thick vapor-dominated zone (> 1000 meter) in a 2.8 km thick reservoir with the permeability of 10-13 m 2. Model simulations are produced that reach steady state at 10.7 kyr, with 38--40 bar and 250--252 ° C reservoir yielding a heatloss of 90 MW and 35 kg/s of steam escaping from the reservoir. This study provided an unusual opportunity to characterize and model volcano-hosted geothermal systems.
30 CFR Appendix I to Subpart D of... - Appendix I to Subpart D of Part 18
Code of Federal Regulations, 2013 CFR
2013-07-01
... 60 °C. copper temperature (40 °C. ambient) Resistance at 60 °C. copper temperature (ohms) 6 550 50 0... Temperature—40 °C. Ambient) Conductor size—AWG or MCM Single conductor 2-conductor, round or flat 3-conductor... 2—Portable Cord Ampacities—600 Volts (Amperes Per Conductor Based on 60 °C. Copper Temperature—40 °C...
Design study of an YBCO-coated beam screen for the super proton-proton collider bending magnets
NASA Astrophysics Data System (ADS)
Gan, Pingping; Zhu, Kun; Fu, Qi; Li, Haipeng; Lu, Yuanrong; Easton, Matt; Liu, Yudong; Tang, Jingyu; Xu, Qingjin
2018-04-01
In order to reduce the beam impedance and refrigeration power dramatically, we have designed a high temperature superconductor (HTS) coated beam screen to screen the cold chamber walls of the super proton-proton collider bending magnets from beam-induced heat loads. It employs an absorber, inspired by the future circular collider studies, to absorb the immense synchrotron radiation power of 12.8 W/m emitted from the 37.5 TeV proton beams. Such a structure has the advantage of decreasing the electron cloud effect and improving the beam vacuum. We have compared the critical magnetic field and current density and accessibility of two potential HTS materials for the beam screen, TlBa2Ca2Cu3O9-δ (Tl-1223) and Yttrium Barium Copper Oxide (YBCO) and finally chose YBCO for coating. The beam screen is tentatively designed to work at 55-70 K because of the limited development of the YBCO material. The thermal analysis with oxygen cooling fluid indicates that the YBCO conductor can maintain its superconductivity even if the synchrotron radiation hits the YBCO-coated surface and the mechanical analysis shows that the structure has the ability to resist the Lorenz force during magnet quenches.
NASA Astrophysics Data System (ADS)
He, Xiang; Chen, Jianping; Zhang, Yachun; Chen, Yudong; Zeng, Xiaojun; Tang, Chunmei
2015-10-01
Some reports presented that the radar cross section (RCS) from the radar antenna of military airplanes can be reduced by using a low-temperature plasma screen. This paper gives a numerical and experimental analysis of this RCS-reduction method. The shape of the plasma screen was designed as a semi-ellipsoid in order to make full use of the space in the radar dome. In simulations, we discussed the scattering of the electromagnetic (EM) wave by a perfect electric conductor (PEC) covered with this plasma screen using the finite-difference-time-domain (FDTD) method. The variations of their return loss as a function of wave frequency, plasma density profile, and collision frequency were presented. In the experiments, a semi-ellipsoidal shaped plasma screen was produced. Electromagnetic attenuation of 1.5 GHz EM wave was measured for a radio frequency (RF) power of 5 kW at an argon pressure of 200-1150 Pa. A good agreement is found between simulated and experimental results. It can be confirmed that the plasma screen is useful in applications for stealth of radar antenna. supported by National Natural Science Foundation of China (No. 51107033) and the Fundamental Research Funds for the Central Universities, China (No. 2013B33614)
Superconducting magnet cooling system
Vander Arend, Peter C.; Fowler, William B.
1977-01-01
A device is provided for cooling a conductor to the superconducting state. The conductor is positioned within an inner conduit through which is flowing a supercooled liquid coolant in physical contact with the conductor. The inner conduit is positioned within an outer conduit so that an annular open space is formed therebetween. Through the annular space is flowing coolant in the boiling liquid state. Heat generated by the conductor is transferred by convection within the supercooled liquid coolant to the inner wall of the inner conduit and then is removed by the boiling liquid coolant, making the heat removal from the conductor relatively independent of conductor length.
Comparison study and thoron interference test of different radon monitors.
Sumesh, C G; Kumar, A Vinod; Tripathi, R M; Puranik, V D
2013-03-01
A comparison study and thoron interference test for different continuous radon monitors were carried out. The comparison study includes three passive diffusion monitors [one pulse ionisation chamber based-Alpha Guard and two silicon semi-conductor based-Radon Scout Plus (RSP)] and one silicon semi-conductor-based active radon thoron discriminating monitor--RAD 7. Radon emanation standard, supplied by National Institute of Science and Technology, has been utilised for the comparison study to qualify the calibration of the continuous radon monitors. All the instruments showed good agreement with the estimated radon concentration using (226)Ra/(222)Rn emanation standard. It was found that the active radon monitoring system is having a higher initial response towards the transient radon concentration than the passive radon monitors studied. The instruments measuring radon concentration without energy discrimination are likely to have some sensitivity towards the thoron concentration. Thus, thoron interference study was carried out in the above monitors. Nine percent interference in measured radon concentration in the Alpha Guard monitor and 4 % interference in the semi-conductor-based RSP monitors was observed. Study indicates that the interference of thoron in radon monitors depends on the area of diffusion of gas, volume of detection and sensitivity factor.
Modeling Test and Treatment Strategies for Presymptomatic Alzheimer Disease
Burke, James F.; Langa, Kenneth M.; Hayward, Rodney A.; Albin, Roger L.
2014-01-01
Objectives In this study, we developed a model of presymptomatic treatment of Alzheimer disease (AD) after a screening diagnostic evaluation and explored the circumstances required for an AD prevention treatment to produce aggregate net population benefit. Methods Monte Carlo simulation methods were used to estimate outcomes in a simulated population derived from data on AD incidence and mortality. A wide variety of treatment parameters were explored. Net population benefit was estimated in aggregated QALYs. Sensitivity analyses were performed by individually varying the primary parameters. Findings In the base-case scenario, treatment effects were uniformly positive, and net benefits increased with increasing age at screening. A highly efficacious treatment (i.e. relative risk 0.6) modeled in the base-case is estimated to save 20 QALYs per 1000 patients screened and 221 QALYs per 1000 patients treated. Conclusions Highly efficacious presymptomatic screen and treat strategies for AD are likely to produce substantial aggregate population benefits that are likely greater than the benefits of aspirin in primary prevention of moderate risk cardiovascular disease (28 QALYS per 1000 patients treated), even in the context of an imperfect treatment delivery environment. PMID:25474698
Architecture for coated conductors
Foltyn, Stephen R.; Arendt, Paul N.; Wang, Haiyan; Stan, Liliana
2010-06-01
Articles are provided including a base substrate having a layer of an oriented cubic oxide material with a rock-salt-like structure layer thereon, and, a layer of epitaxial titanium nitride upon the layer of an oriented cubic oxide material having a rock-salt-like structure. Such articles can further include thin films of high temperature superconductive oxides such as YBCO upon the layer of epitaxial titanium nitride or upon a intermediate buffer layer upon the layer of epitaxial titanium nitride.
Varma, Sandeep R; Sivaprakasam, Thiyagarajan O; Mishra, Abheepsa; Prabhu, Sunil; M, Rafiq; P, Rangesh
2017-10-15
Psoriasis is considered to be a systemic disease of immune dysfunction. It is still unclear what triggers the inflammatory cascade associated with psoriasis but recent evidences suggest the vital role of IL-23/IL-17A cytokine axis in etiology of psoriasis. Several studies have been conducted in psoriatic-like animal models but ethical issues and complexity surrounding it halts the screening of new anti-psoriatic drug candidates. Hence, in this study, we developed a new in-vitro model for psoriasis using imiquimod (IMQ) induced differentiated HaCaT cells which could be used for screening of new anti-psoriatic drug candidates. The differentiated HaCaT cells were treated with IMQ (100μM) to induce psoriatic like inflammation and its effect was investigated using a natural anti-psoriatic compound, curcumin. The proliferation of psoriatic-like cells was inhibited by curcumin at 25 and 50µM concentrations. The psoriatic-like cells decreased in number with increase in apoptotic and dead cells upon curcumin treatment. Curcumin inhibited the proliferation of IMQ-induced differentiated HaCaT cells (Psoriatic-like cells) by down-regulation of pro-inflammatory cytokines, interleukin-17, tumor necrosis factor-α, interferon-γ, and interleukin-6. Apart from this, curcumin significantly enhanced the skin-barrier function by up-regulation of involucrin (iNV) and filaggrin (FLG), the regulators of epidermal skin barrier. The IMQ-induced differentiated HaCaT in vitro model recapitulated some aspects of the psoriasis pathogenesis similar to murine model. Henceforth, we conclude that this model may be used for rapid screening of anti-psoriatic drug candidates and warrant further mechanistic studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Prostate cancer screening behavior in men from seven ethnic groups: the fear factor.
Consedine, Nathan S; Morgenstern, Amy H; Kudadjie-Gyamfi, Elizabeth; Magai, Carol; Neugut, Alfred I
2006-02-01
Rates of prostate cancer screening are known to vary among the major ethnic groups. However, likely variations in screening behavior among ethnic subpopulations and the likely role of psychological characteristics remain understudied. We examined differences in prostate cancer screening among samples of 44 men from each of seven ethnic groups (N = 308; U.S.-born European Americans, U.S.-born African Americans, men from the English-speaking Caribbean, Haitians, Dominicans, Puerto Ricans, and Eastern Europeans) and the associations among trait fear, emotion regulatory characteristics, and screening. As expected, there were differences in the frequency of both digital rectal exam (DRE) and prostate-specific antigen (PSA) tests among the groups, even when demographic factors and access were controlled. Haitian men reported fewer DRE and PSA tests than either U.S.-born European American or Dominican men, and immigrant Eastern European men reported fewer tests than U.S.-born European Americans; consistent with prior research, U.S.-born African Americans differed from U.S.-born European Americans for DRE but not PSA frequency. Second, the addition of trait fear significantly improved model fit, as did the inclusion of a quadratic, inverted U, trait fear term, even where demographics, access, and ethnicity were controlled. Trait fear did not interact with ethnicity, suggesting its effect may operate equally across groups, and adding patterns of information processing and emotion regulation to the model did not improve model fit. Overall, our data suggest that fear is among the key psychological determinants of male screening behavior and would be usefully considered in models designed to increase male screening frequency.
Thermal oxidative degradation of ethylene tetrafluoroethylene copolymer systems
NASA Astrophysics Data System (ADS)
Elders, Jonathan Patrick
Thermo-oxidative degradation of ethylene tetrafluoroethylene (ETFE) was investigated to determine how modifications for use in an electrical wire system affected its thermal stability. Modifications included electron irradiation and subsequent cross-linking during manufacture and contact with a metal surface. Samples with irradiation histories between 0 and 48 MRads were investigated. Degradation of ETFE was enhanced by contact with a metal "conductor" surface: silver - coated copper. Polymer degradation was analyzed by weight loss kinetics (thermogravimetric analysis (TGA)), changes in polymer morphology (differential scanning calorimetry (DSC)), optical microscopy, attenuated total reflectance (ATR) infrared spectroscopy, and gas chromatography - mass spectroscopy (GC/MS). Conductor aging (copper permeation through silver with subsequent oxidation) was investigated using scanning Auger Electron Spectroscopy (AES). Conductor aging is enhanced in the presence of the polymer surface. Interactions between conductor and polymer were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The rate of polymer degradation from 220°C to 280°C was independent of time and extent of degradation, and rate was proportional to irradiation dose. The activation energy for degradation of unirradiated ETFE was 227 kJ/mol and decreased from 150 to 138 kJ/mol for ETFE irradiated to doses between 6 and 48 MRads. Rates of degradation at 300°C to 320°C were dependent on the extent of degradation. Rates of degradation at temperatures between 230°C and 310°C were an order of magnitude larger in the presence of a conductor than in its absence, and activation energies for degradation in the presence of conductor were reduced to 120 kJ/mol. Degradation was modeled as the combination of bulk polymer degradation and catalytic degradation at the polymer-metal interface. ETFE aged at 250°C in the presence or absence of a conductor exhibited a double melting endotherm. ATR spectra of aged ETFE indicated polymer oxidation. Based on AES experiments, copper permeation during aging in the presence or absence of ETFE was consistent with Fickian diffusion. The coefficient for copper diffusion through silver was approximately 10 -15 cm2/second, and catalytic ETFE degradation was proportional to conductor aging. The copper oxidized on the surface to yield a material with a stoichiometric composition of Cu3O 2.
Developing Musicality: Formal and Informal Practices
ERIC Educational Resources Information Center
Jaffurs, Sheri E.
2004-01-01
Musicality is a loosely used term with many meanings. It can be applied to a small child who chants a nursery rhyme, or to a harmonica player who plays by ear, or to a conductor like Toscanini. Some educators and philosophers believe that musicality is manifested in the technical achievements of musicians. Others believe that technique is…
Screening fifth forces in k-essence and DBI models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brax, Philippe; Burrage, Clare; Davis, Anne-Christine, E-mail: Philippe.Brax@cea.fr, E-mail: Clare.Burrage@nottingham.ac.uk, E-mail: A.C.Davis@damtp.cam.ac.uk
New fifth forces have not yet been detected in the laboratory or in the solar system, hence it is typically difficult to introduce new light scalar fields that would mediate such forces. In recent years it has been shown that a number of non-linear scalar field theories allow for a dynamical mechanism, such as the Vainshtein and chameleon ones, that suppresses the strength of the scalar fifth force in experimental environments. This is known as screening, however it is unclear how common screening is within non-linear scalar field theories. k-essence models are commonly studied examples of non-linear models, with DBImore » as the best motivated example, and so we ask whether these non-linearities are able to screen a scalar fifth force. We find that a Vainshtein-like screening mechanism exists for such models although with limited applicability. For instance, we cannot find a screening mechanism for DBI models. On the other hand, we construct a large class of k-essence models which lead to the acceleration of the Universe in the recent past for which the fifth force mediated by the scalar can be screened.« less
Cost effectiveness of screening immigrants for hepatitis B.
Wong, William W L; Woo, Gloria; Jenny Heathcote, E; Krahn, Murray
2011-09-01
The prevalence of chronic hepatitis B (CHB) infection among the immigrants of North America ranges from 2 to 15%, among whom 40% develop advanced liver disease. Screening for hepatitis B surface antigen is not recommended for immigrants. The objective of this study is to estimate the health and economic effects of screening strategies for CHB among immigrants. We used the Markov model to examine the cost-effectiveness of three screening strategies: (i) 'No screening'; (ii) 'Screen and Treat' and (iii) 'Screen, Treat and Vaccinate' for 20-65 years old individuals who were born abroad but are currently living in Canada. Model data were obtained from the published literature. We measured predicted hepatitis B virus (HBV)-related deaths, costs (2008 Canadian Dollars), quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratio (ICER). Our results show that screening all immigrants will prevent 59 HBV-related deaths per 10, 000 persons screened over the lifetime of the cohort. Screening was associated with an increase in quality-adjusted life expectancy (0.024 QALYs) and cost ($1665) per person with an ICER of $69, 209/QALY gained compared with 'No screening'. The 'Screen, Treat and Vaccinate' costs an additional $81, generates an additional 0.000022 QALYs per person, with an ICER of $3, 648,123/QALY compared with the 'Screen and Treat'. Sensitivity analyses suggested that the 'Screen and Treat' is likely to be moderately cost-effective. We show that a selective hepatitis B screening programme targeted at all immigrants in Canada is likely to be moderately cost-effective. Identification of silent CHB infection with the offer of treatment when appropriate can extend the lives of immigrants at reasonable cost. © 2011 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Desmarais, Jacques K.; Smith, Richard S.
2016-03-01
A novel automatic data interpretation algorithm is presented for modelling airborne electromagnetic (AEM) data acquired over resistive environments, using a single-component (vertical) transmitter, where the position and orientation of a dipole conductor is allowed to vary in three dimensions. The algorithm assumes that the magnetic fields produced from compact vortex currents are expressed as a linear combinations of the fields arising from dipoles in the subsurface oriented parallel to the [1, 0, 0], [0, 1, 0], and [0, 0, 1], unit vectors. In this manner, AEM responses can be represented as 12 terms. The relative size of each term in the decomposition can be used to determine geometrical information about the orientation of the subsurface conductivity structure. The geometrical parameters of the dipole (location, depth, dip, strike) are estimated using a combination of a look-up table and a matrix inverted in a least-squares sense. Tests on 703 synthetic models show that the algorithm is capable of extracting most of the correct geometrical parameters of a dipole conductor when three-component receiver data is included in the interpretation procedure. The algorithm is unstable when the target is perfectly horizontal, as the strike is undefined. Ambiguities may occur in predicting the orientation of the dipole conductor if y-component data is excluded from the analysis. Application of our approach to an anomaly on line 15 of the Reid Mahaffy test site yields geometrical parameters in reasonable agreement with previous authors. However, our algorithm provides additional information on the strike and offset from the traverse line of the conductor. Disparities in the values of predicted dip and depth are within the range of numerical precision. The index of fit was better when strike and offset were included in the interpretation procedure. Tests on the data from line 15701 of the Chibougamau MEGATEM survey shows that the algorithm is applicable to situations where three-component AEM data is available.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Conductors. 159.73 Section 159.73 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.73 Conductors. Current carrying conductors must be...
30 CFR 7.403 - Application requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., round or flat). (iii) Number and size (gauge) of each conductor. (iv) Voltage rating for all cables containing electric conductors. (v) For electric cables, current-carrying capacity of each conductor, with corresponding ambient temperature upon which the current rating (ampacity) is based, of each power conductor. (2...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Conductors. 159.73 Section 159.73 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.73 Conductors. Current carrying conductors must be...
30 CFR 57.12010 - Isolation or insulation of communication conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conductors. 57.12010 Section 57.12010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... conductors. Telephone and low-potential signal wire shall be protected, by isolation or suitable insulation, or both, from contacting energized power conductors or any other power source. ...
30 CFR 57.12010 - Isolation or insulation of communication conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conductors. 57.12010 Section 57.12010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... conductors. Telephone and low-potential signal wire shall be protected, by isolation or suitable insulation, or both, from contacting energized power conductors or any other power source. ...
Xue, Mianqiang; Yan, Guoqing; Li, Jia; Xu, Zhenming
2012-10-02
Electrostatic separation has been widely used to separate conductors and nonconductors for recycling e-waste. However, the components of e-waste are complex, which can be classified as conductors, semiconductors, and nonconductors according to their conducting properties. In this work, we made a novel attempt to recover the mixtures containing conductors (copper), semiconductors (extrinsic silicon), and nonconductors (woven glass reinforced resin) by electrostatic separation. The results of binary mixtures separation show that the separation of conductor and nonconductor, semiconductor and nonconductor need a higher voltage level while the separation of conductor and semiconductor needs a higher roll speed. Furthermore, the semiconductor separation efficiency is more sensitive to the high voltage level and the roll speed than the conductor separation efficiency. An integrated process was proposed for the multiple mixtures separation. The separation efficiency of conductors and semiconductors can reach 82.5% and 88%, respectively. This study contributes to the efficient recycling of valuable resources from e-waste.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, P.; Pham, K.
1995-12-31
Under emergency conditions, a bare overhead conductor can carry an increased amount of current that is well in excess of its normal rating. When there is this increase in current flow on a bare overhead conductor, the temperature does not rise instantaneously. but increases along a curve determined by the current, the conductor properties and the ambient conditions. The conductor temperature at the end of a short-time overload period must be restricted to its maximum design value. This paper presents a simplified approach in analyzing the dynamic performance for bare overhead conductors during short-time overload condition. A computer program wasmore » developed to calculate the short-time ratings for bare overhead conductors. The following parameters: current induced heating. solar load, convective/conductive cooling, radiative cooling, altitude, wind velocity and ampacity of the bare conductor were considered. Several sample graphical output lots are included with the paper.« less
Structure for monolithic optical circuits
NASA Technical Reports Server (NTRS)
Evanchuk, Vincent L. (Inventor)
1984-01-01
A method for making monolithic optical circuits, with related optical devices as required or desired, on a supporting surface (10) consists of coating the supporting surface with reflecting metal or cladding resin, spreading a layer of liquid radiation sensitive plastic (12) on the surface, exposing the liquid plastic with a mask (14) to cure it in a desired pattern of light conductors (16, 18, 20), washing away the unexposed liquid plastic, and coating the conductors thus formed with reflective metal or cladding resin. The index of refraction for the cladding (22) is selected to be lower than for the conductors so that light in the conductors will be reflected by the interface with the cladding. For multiple level conductors, as where one conductor must cross over another, the process may be repeated to fabricate a bridge with columns (24, 26) of conductors to the next level, and conductor (28) between the columns. For more efficient transfer of energy over the bridge, faces at 45.degree. may be formed to reflect light up and across the bridge.
Cheng, Yongqiang; Balachandran, Janakiraman; Bi, Zhonghe; ...
2017-07-18
The local structure around the mobile ions influences their dynamics. The knowledge about the relationship between these properties is of fundamental importance and may lead the way for development of improved solid state ionic conductors. Here, we use inelastic neutron scattering and ab initio modeling to study a representative proton conductor, La 0.8Ba 1.2GaO 3.9, where different local structures are possible for the same stoichiometry. The intrinsic correlations between the local bonding environment and the dynamical behavior of protons are presented. In particular, we identify how the local Ba/La concentration affects the proton vibrational frequencies, hydrogen bond strength, O–H rotationsmore » and in turn long-range proton mobility. Furthermore, possible mechanism for proton transport, through the inter-tetrahedral bond switching, O–H rotations and tetrahedral reorientation is anticipated.« less
Hard X-ray and low-energy gamma-ray spectrometers
NASA Technical Reports Server (NTRS)
Gehrels, N.; Crannell, C. J.; Orwig, L. E.; Forrest, D. J.; Lin, R. P.; Starr, R.
1988-01-01
Basic principles of operation and characteristics of scintillation and semi-conductor detectors used for solar hard X-ray and gamma-ray spectrometers are presented. Scintillation materials such as NaI offer high stopping power for incident gamma rays, modest energy resolution, and relatively simple operation. They are, to date, the most often used detector in solar gamma-ray spectroscopy. The scintillator BGO has higher stopping power than NaI, but poorer energy resolution. The primary advantage of semi-conductor materials such as Ge is their high-energy resolution. Monte-Carlo simulations of the response of NaI and Ge detectors to model solar flare inputs show the benefit of high resoluton for studying spectral lines. No semi-conductor material besides Ge is currently available with adequate combined size and purity to make general-use hard X-ray and gamma-ray detectors for solar studies.
NASA Astrophysics Data System (ADS)
Pasztor, G.; Bruzzone, P.
2004-06-01
The dc performance of a recently produced internal tin route Nb3Sn strand with enhanced specification is studied extensively and compared with predecessor wires manufactured by the suppliers for the ITER Model Coils in 1996. The wire has been selected for use in a full size, developmental cable-in-conduit conductor sample, which is being tested in the SULTAN Test Facility. The critical current, Ic, and the index of the current/voltage characteristic, n, are measured over a broad range of field and temperature, using ITER standard sample holders, made of TiAlV grooved cylinders. The behavior of Ic versus applied tensile strain is also investigated at 4.2 K and 12 T, on straight specimens. Scaling law parameters are drawn from the fit of the experimental results. The implications of the test results to the design of the fusion conductors are discussed.
Hall, David R [Provo, UT; Fox, Joe [Spanish Fork, UT
2008-01-15
A transmission system in a downhole component comprises a data transmission element in both ends of the downhole component. Each data transmission element houses an electrically conducting coil in a MCEI circular trough. An electrical conductor connects both the transmission elements. The electrical conductor comprises at least three electrically conductive elements insulated from each other. In the preferred embodiment the electrical conductor comprises an electrically conducting outer shield, an electrically conducting inner shield and an electrical conducting core. In some embodiments of the present invention, the electrical conductor comprises an electrically insulating jacket. In other embodiments, the electrical conductor comprises a pair of twisted wires. In some embodiments, the electrical conductor comprises semi-conductive material.
Cluster-inspired Superionic Conductors
NASA Astrophysics Data System (ADS)
Fang, Hong; Jena, Puru
Superionic conductors with desirable properties hold the key to the development of next generation of rechargeable metal-ion batteries. In this study, we report a new family of superionic conductors composed by clusters based on the antiperovskite fast-ion conductors. The new lightweight conductor shows larger electrochemical stability window and favorable thermal and mechanical properties, while maintain a high Li+-ionconductivity at room temperature and a low activation energy. We reveal the conduction mechanism of the material by identifying the relation between the orientational symmetry of the cluster rotors and the potential surface felt by the lithium ion. We also find that the mixed phase of the new conductors show further enhanced conductivity.
Multiwire conductor having greatly increased interwire resistance and method for making same
Luhman, Thomas; Suenaga, Masaki
1984-01-17
An improved multiwire conductor of the type which is mechanically stabilized by a tin based solder filler. A solder filled conductor is heated to a temperature above its melting point for a period long enough to allow a substantial amount of copper to be dissolved from the wires comprising the conductor. The copper forms the brittle intermetallic compound Cu.sub.5 Sn.sub.6 with tin in the solder. After cooling the conductor is flexed causing a random cracking of the solder, and thereby increasing the interwire resistance of the conductor. The subject invention is particularly adapted for use with braided, ribbon-type solder filled superconductors.
Luhman, Thomas; Klamut, Carl
1984-02-14
An improved multiwire conductor of the type which is mechanically stabilized by a solder filler. A solder filled conductor is heated to a temperature sufficient to make the solder brittle, but below the melting point of the solder. While still hot, the conductor is flexed, causing the solder to separate from the wires comprising the conductor, thereby increasing the interwire resistance. In one embodiment the conductor may be heated to a temperature above the eutectic temperature of the solder so that a controlled amount of solder is removed. The subject invention is particularly suited for use with braided, ribbon-type, solder filled superconductors.
Luhman, T.; Klamut, C.
1982-03-15
An improved multiwire conductor of the type which is mechanically stabilized by a solder filler. A solder filled conductor is heated to a temperature sufficient to make the solder brittle, but below the melting point of the solder. While still hot, the conductor is flexed, causing the solder to separate from the wires comprising the conductor, thereby increasing the interwire resistance. In one embodiment the conductor may be heated to a temperature above the eutectic temperature of the solder so that a controlled amount of solder is removed. The subject invention is particularly suited for use with braided, ribbon-type, solder filled superconductors.
MQXFS1 Quadrupole Fabrication Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ambrosio, G.; Anerella, M.; Bossert, R.
This report presents the fabrication and QC data of MQXFS1, the first short model of the low-beta quadrupoles (MQXF) for the LHC High Luminosity Upgrade. It describes the conductor, the coils, and the structure that make the MQXFS1 magnet. Qualification tests and non-conformities are also presented and discussed. The fabrication of MQXFS1 was started before the finalization of conductor and coil design for MQXF magnets. Two strand design were used (RRP 108/127 and RRP 132/169). Cable and coil cross-sections were “first generation”.
Solving time-dependent two-dimensional eddy current problems
NASA Technical Reports Server (NTRS)
Lee, Min Eig; Hariharan, S. I.; Ida, Nathan
1990-01-01
Transient eddy current calculations are presented for an EM wave-scattering and field-penetrating case in which a two-dimensional transverse magnetic field is incident on a good (i.e., not perfect) and infinitely long conductor. The problem thus posed is of initial boundary-value interface type, where the boundary of the conductor constitutes the interface. A potential function is used for time-domain modeling of the situation, and finite difference-time domain techniques are used to march the potential function explicitly in time. Attention is given to the case of LF radiation conditions.
30 CFR 75.1002 - Installation of electric equipment and conductors; permissibility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conductors; permissibility. 75.1002 Section 75.1002 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Wires and Trolley Feeder Wires § 75.1002 Installation of electric equipment and conductors... equipment is located within 150 feet of pillar workings or longwall faces. (b) Electric conductors and...
30 CFR 75.513 - Electric conductor; capacity and insulation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric conductor; capacity and insulation. 75.513 Section 75.513 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... § 75.513 Electric conductor; capacity and insulation. [Statutory Provision] All electric conductors...
30 CFR 75.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conduits enclosing power conductors. 75.700 Section 75.700 Mineral Resources MINE SAFETY AND HEALTH... Grounding § 75.700 Grounding metallic sheaths, armors, and conduits enclosing power conductors. [Statutory Provisions] All metallic sheaths, armors, and conduits enclosing power conductors shall be electrically...
30 CFR 77.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conduits enclosing power conductors. 77.700 Section 77.700 Mineral Resources MINE SAFETY AND HEALTH..., and conduits enclosing power conductors. Metallic sheaths, armors, and conduits enclosing power conductors shall be electrically continuous throughout and shall be grounded by methods approved by an...
30 CFR 75.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conduits enclosing power conductors. 75.700 Section 75.700 Mineral Resources MINE SAFETY AND HEALTH... Grounding § 75.700 Grounding metallic sheaths, armors, and conduits enclosing power conductors. [Statutory Provisions] All metallic sheaths, armors, and conduits enclosing power conductors shall be electrically...
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... protection must be provided for each ungrounded conductor, to open the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or its insulation. (b) Each conductor of a control, interlock, or indicator circuit, such as a conductor for an instrument...
46 CFR 120.380 - Overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch or circuit breaker, unless...
46 CFR 120.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch or circuit breaker, unless...
30 CFR 77.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conduits enclosing power conductors. 77.700 Section 77.700 Mineral Resources MINE SAFETY AND HEALTH..., and conduits enclosing power conductors. Metallic sheaths, armors, and conduits enclosing power conductors shall be electrically continuous throughout and shall be grounded by methods approved by an...
30 CFR 75.1002 - Installation of electric equipment and conductors; permissibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conductors; permissibility. 75.1002 Section 75.1002 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... Wires and Trolley Feeder Wires § 75.1002 Installation of electric equipment and conductors... equipment is located within 150 feet of pillar workings or longwall faces. (b) Electric conductors and...
30 CFR 75.513 - Electric conductor; capacity and insulation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductor; capacity and insulation. 75.513 Section 75.513 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... § 75.513 Electric conductor; capacity and insulation. [Statutory Provision] All electric conductors...
46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...
46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...
46 CFR 111.05-33 - Equipment safety grounding (bonding) conductors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Equipment safety grounding (bonding) conductors. 111.05... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-33 Equipment safety grounding (bonding) conductors. (a) Each equipment-grounding conductor must...
33 CFR 159.71 - Electrical controls and conductors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Electrical controls and... Electrical controls and conductors. Electrical controls and conductors must be installed in accordance with good marine practice. Wire must be copper and must be stranded. Electrical controls and conductors must...
33 CFR 159.71 - Electrical controls and conductors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Electrical controls and... Electrical controls and conductors. Electrical controls and conductors must be installed in accordance with good marine practice. Wire must be copper and must be stranded. Electrical controls and conductors must...
33 CFR 159.71 - Electrical controls and conductors.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Electrical controls and... Electrical controls and conductors. Electrical controls and conductors must be installed in accordance with good marine practice. Wire must be copper and must be stranded. Electrical controls and conductors must...
Laser drilling of vias in dielectric for high density multilayer LSHI thick film circuits
NASA Technical Reports Server (NTRS)
Cocca, T.; Dakesian, S.
1977-01-01
A design analysis of a high density multilevel thick film digital microcircuit used for large scale integration is presented. The circuit employs 4 mil lines, 4 mil spaces and requires 4 mil diameter vias. Present screened and fired thick film technology is limited on a production basis to 16 mil square vias. A process whereby 4 mil diameter vias can be fabricated in production using laser technology was described along with a process to produce 4 mil diameter vias for conductor patterns which have 4 mil lines and 4 mil spacings.
Superaligned carbon nanotube arrays, films, and yarns: a road to applications.
Jiang, Kaili; Wang, Jiaping; Li, Qunqing; Liu, Liang; Li, Changhong; Fan, Shoushan
2011-03-04
A superaligned carbon nanotube (CNT) array is a special kind of vertically aligned CNT array with the capability of being converted into continuous fi lms and yarns. The as-produced CNT fi lms are transparent and highly conductive, with aligned CNTs parallel to the direction of drawing. After passing through volatile solutions or being twisted, CNT fi lms can be further condensed into shrunk yarns. These shrunk yarns possess high tensile strengths and Young’s moduli, and are good conductors. Many applications of CNT fi lms and shrunk yarns have been demonstrated, such as TEM grids, loudspeakers, touch screens, etc.
Implications of the Babinet Principle for Casimir interactions
NASA Astrophysics Data System (ADS)
Maghrebi, Mohammad F.; Jaffe, Robert L.; Abravanel, Ronen
2011-09-01
We formulate the Babinet Principle (BP) as a relation between scattering amplitudes and combine it with multiple scattering techniques to derive new properties of electromagnetic Casimir forces. We show that the Casimir force exerted by a planar conductor or dielectric on a self-complementary perforated planar mirror is approximately half that on a uniform mirror independent of the distance between them. Also, the BP suggests that Casimir edge effects are generically anomalously small. Furthermore, the BP can be used to relate any planar object to its complementary geometry, a relation we use to estimate Casimir forces between two screens with apertures.
Resistive coating for current conductors in cryogenic applications
Hirayama, Chikara; Wagner, George R.
1982-05-18
This invention relates to a resistive or semiconducting coating for use on current conductors in cryogenic applications. This includes copper-clad superconductor wire, copper wire used for stabilizing superconductor magnets, and for hyperconductors. The coating is a film of cuprous sulfide (Cu.sub.2 S) that has been found not to degrade the properties of the conductors. It is very adherent to the respective conductors and satisfies the mechanical, thermal and electrical requirements of coatings for the conductors.
High pressure, high current, low inductance, high reliability sealed terminals
Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN
2010-03-23
The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.
30 CFR 57.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Communication conductors on power poles. 57... MINES Electricity Surface and Underground § 57.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried...
46 CFR 183.372 - Equipment and conductor grounding.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Equipment and conductor grounding. 183.372 Section 183... conductor grounding. (a) All metallic enclosures and frames of electrical equipment must be permanently... equipment must be bonded together to a common ground by a normally non-current carrying conductor. Metallic...
30 CFR 57.12005 - Protection of power conductors from mobile equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of power conductors from mobile... NONMETAL MINES Electricity Surface and Underground § 57.12005 Protection of power conductors from mobile equipment. Mobile equipment shall not run over power conductors, nor shall loads be dragged over power...
33 CFR 183.455 - Overcurrent protection: General.
Code of Federal Regulations, 2011 CFR
2011-07-01
....455 Overcurrent protection: General. (a) Each ungrounded current-carrying conductor must be protected... breaker or fuse must be placed at the source of power for each circuit or conductor except: (1) If it is... seven inches of the source of power for each circuit or conductor measured along the conductor. (2) If...
46 CFR 120.372 - Equipment and conductor grounding.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Equipment and conductor grounding. 120.372 Section 120... INSTALLATION Power Sources and Distribution Systems § 120.372 Equipment and conductor grounding. (a) All... together to a common ground by a normally non-current carrying conductor. Metallic cases of instruments and...
46 CFR 183.380 - Overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch...
46 CFR 183.372 - Equipment and conductor grounding.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Equipment and conductor grounding. 183.372 Section 183... conductor grounding. (a) All metallic enclosures and frames of electrical equipment must be permanently... equipment must be bonded together to a common ground by a normally non-current carrying conductor. Metallic...
46 CFR 183.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch...
30 CFR 77.503 - Electric conductors; capacity and insulation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric conductors; capacity and insulation... UNDERGROUND COAL MINES Electrical Equipment-General § 77.503 Electric conductors; capacity and insulation. Electric conductors shall be sufficient in size and have adequate current carrying capacity and be of such...
30 CFR 57.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Communication conductors on power poles. 57... MINES Electricity Surface and Underground § 57.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried...
30 CFR 75.513-1 - Electric conductor; size.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric conductor; size. 75.513-1 Section 75.513-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... Electric conductor; size. An electric conductor is not of sufficient size to have adequate carrying...
30 CFR 56.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Communication conductors on power poles. 56... Electricity § 56.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried on poles supporting...
30 CFR 77.503 - Electric conductors; capacity and insulation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductors; capacity and insulation... UNDERGROUND COAL MINES Electrical Equipment-General § 77.503 Electric conductors; capacity and insulation. Electric conductors shall be sufficient in size and have adequate current carrying capacity and be of such...
21 CFR 868.1920 - Esophageal stethoscope with electrical conductors.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Esophageal stethoscope with electrical conductors... stethoscope with electrical conductors. (a) Identification. An esophageal stethoscope with electrical conductors is a device that is inserted into the esophagus to listen to a patient's heart and breath sounds...
30 CFR 56.12048 - Communication conductors on power poles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Communication conductors on power poles. 56... Electricity § 56.12048 Communication conductors on power poles. Telegraph, telephone, or signal wires shall not be installed on the same crossarm with power conductors. When carried on poles supporting...
46 CFR 120.372 - Equipment and conductor grounding.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Equipment and conductor grounding. 120.372 Section 120... INSTALLATION Power Sources and Distribution Systems § 120.372 Equipment and conductor grounding. (a) All... together to a common ground by a normally non-current carrying conductor. Metallic cases of instruments and...
33 CFR 183.455 - Overcurrent protection: General.
Code of Federal Regulations, 2010 CFR
2010-07-01
....455 Overcurrent protection: General. (a) Each ungrounded current-carrying conductor must be protected... breaker or fuse must be placed at the source of power for each circuit or conductor except: (1) If it is... seven inches of the source of power for each circuit or conductor measured along the conductor. (2) If...
30 CFR 57.12005 - Protection of power conductors from mobile equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Protection of power conductors from mobile... NONMETAL MINES Electricity Surface and Underground § 57.12005 Protection of power conductors from mobile equipment. Mobile equipment shall not run over power conductors, nor shall loads be dragged over power...
21 CFR 868.1920 - Esophageal stethoscope with electrical conductors.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal stethoscope with electrical conductors... stethoscope with electrical conductors. (a) Identification. An esophageal stethoscope with electrical conductors is a device that is inserted into the esophagus to listen to a patient's heart and breath sounds...
30 CFR 75.513-1 - Electric conductor; size.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductor; size. 75.513-1 Section 75.513-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... Electric conductor; size. An electric conductor is not of sufficient size to have adequate carrying...
29 CFR 1910.305 - Wiring methods, components, and equipment for general use.
Code of Federal Regulations, 2010 CFR
2010-07-01
... distribution center. (B) Conductors shall be run as multiconductor cord or cable assemblies. However, if... persons, feeders may be run as single insulated conductors. (v) The following requirements apply to branch... shall be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they...
29 CFR 1910.305 - Wiring methods, components, and equipment for general use.
Code of Federal Regulations, 2011 CFR
2011-07-01
... distribution center. (B) Conductors shall be run as multiconductor cord or cable assemblies. However, if... persons, feeders may be run as single insulated conductors. (v) The following requirements apply to branch... shall be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they...
29 CFR 1910.305 - Wiring methods, components, and equipment for general use.
Code of Federal Regulations, 2013 CFR
2013-07-01
... distribution center. (B) Conductors shall be run as multiconductor cord or cable assemblies. However, if... persons, feeders may be run as single insulated conductors. (v) The following requirements apply to branch... shall be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they...
29 CFR 1910.305 - Wiring methods, components, and equipment for general use.
Code of Federal Regulations, 2014 CFR
2014-07-01
... distribution center. (B) Conductors shall be run as multiconductor cord or cable assemblies. However, if... persons, feeders may be run as single insulated conductors. (v) The following requirements apply to branch... shall be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they...
29 CFR 1910.305 - Wiring methods, components, and equipment for general use.
Code of Federal Regulations, 2012 CFR
2012-07-01
... distribution center. (B) Conductors shall be run as multiconductor cord or cable assemblies. However, if... persons, feeders may be run as single insulated conductors. (v) The following requirements apply to branch... shall be multiconductor cord or cable assemblies or open conductors. If run as open conductors, they...
30 CFR 75.513-1 - Electric conductor; size.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric conductor; size. 75.513-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.513-1 Electric conductor; size. An electric conductor is not of sufficient size to have adequate carrying...
30 CFR 75.513-1 - Electric conductor; size.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric conductor; size. 75.513-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.513-1 Electric conductor; size. An electric conductor is not of sufficient size to have adequate carrying...
30 CFR 75.513-1 - Electric conductor; size.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric conductor; size. 75.513-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.513-1 Electric conductor; size. An electric conductor is not of sufficient size to have adequate carrying...
30 CFR 77.508 - Lightning arresters, ungrounded and exposed power conductors and telephone wires.
Code of Federal Regulations, 2011 CFR
2011-07-01
... power conductors and telephone wires. 77.508 Section 77.508 Mineral Resources MINE SAFETY AND HEALTH... arresters, ungrounded and exposed power conductors and telephone wires. All ungrounded, exposed power conductors and telephone wires shall be equipped with suitable lightning arresters which are adequately...
30 CFR 77.508 - Lightning arresters, ungrounded and exposed power conductors and telephone wires.
Code of Federal Regulations, 2010 CFR
2010-07-01
... power conductors and telephone wires. 77.508 Section 77.508 Mineral Resources MINE SAFETY AND HEALTH... arresters, ungrounded and exposed power conductors and telephone wires. All ungrounded, exposed power conductors and telephone wires shall be equipped with suitable lightning arresters which are adequately...
Conditioning flat conductors for flat conductor cable production
NASA Technical Reports Server (NTRS)
1968-01-01
Apparatus can straighten, anneal, clean, and a tension to stretch a cable one percent to assure uniform cross-sectional area. A conductor passes through temperature controlled distilled water and through a toroid coil. As The conductor enters the water, steam performs the cleaning action. Quenching and annealing also take place.
46 CFR 111.50-3 - Protection of conductors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Protection of conductors. 111.50-3 Section 111.50-3...-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-3 Protection of conductors. (a) Purpose. The purpose of overcurrent protection for conductors is to open the electric circuit if the current reaches a...
46 CFR 111.50-3 - Protection of conductors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of conductors. 111.50-3 Section 111.50-3...-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-3 Protection of conductors. (a) Purpose. The purpose of overcurrent protection for conductors is to open the electric circuit if the current reaches a...
30 CFR 77.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2014 CFR
2014-07-01
... in resistance grounded systems, where the enclosed conductors are a part of the system, will be approved if a solid connection is made to the neutral conductor; in all other systems, the following... earth; (b) A solid connection to a grounding conductor, other than the neutral conductor of a resistance...
30 CFR 77.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in resistance grounded systems, where the enclosed conductors are a part of the system, will be approved if a solid connection is made to the neutral conductor; in all other systems, the following... earth; (b) A solid connection to a grounding conductor, other than the neutral conductor of a resistance...
NASA Astrophysics Data System (ADS)
Sakkiah, Sugunadevi; Thangapandian, Sundarapandian; John, Shalini; Lee, Keun Woo
2011-01-01
This study was performed to find the selective chemical features for Aurora kinase-B inhibitors using the potent methods like Hip-Hop, virtual screening, homology modeling, molecular dynamics and docking. The best hypothesis, Hypo1 was validated toward a wide range of test set containing the selective inhibitors of Aurora kinase-B. Homology modeling and molecular dynamics studies were carried out to perform the molecular docking studies. The best hypothesis Hypo1 was used as a 3D query to screen the chemical databases. The screened molecules from the databases were sorted based on ADME and drug like properties. The selective hit compounds were docked and the hydrogen bond interactions with the critical amino acids present in Aurora kinase-B were compared with the chemical features present in the Hypo1. Finally, we suggest that the chemical features present in the Hypo1 are vital for a molecule to inhibit the Aurora kinase-B activity.
Electrical structure of the central Cascadia subduction zone: The EMSLAB Lincoln Line revisited
NASA Astrophysics Data System (ADS)
Evans, Rob L.; Wannamaker, Philip E.; McGary, R. Shane; Elsenbeck, Jimmy
2014-09-01
The EMSLAB experiment was an ambitious onshore-offshore magnetotelluric (MT) transect of the Cascadia subduction zone. When completed (1985-1988), it was the largest experiment of its kind. Modeling and inversion capabilities at the time were, however, not sufficiently sophisticated to handle a fully regularized inversion of the data, including the seafloor data and bathymetric constraints, with the main final model presented based on trial and error forward modeling of the responses. Moreover, new data collected as part of the Earthscope USArray program are of higher quality due to improvements in instrument technology, and augment the original EMSLAB data set, presenting an opportunity to revisit the structure in this part of the subduction system. We have integrated the original wide-band MT data as well as several long-period stations from the original EMSLAB data set and invert these in conjunction with EMSLAB seafloor responses and new Earthscope data on land. This new composite data set has been analyzed in several ways, within a two-dimensional geometry in which conductivity is assumed to be invariant along a strike direction roughly coincident with that of the subduction zone. We have solved for fully smooth regularized models, as well as solutions that allow discontinuities in conductivity along the top surface of the descending slab. Finally, we have tested specific features in the EMSLAB model, notably a moderately shallow ( 30 km depth) forearc conductor. A feature similar to this shallow conductor is a consistent and required feature in our new inversion models, but the new models highlight the connection between the slab and what is interpreted to be an accumulation of aqueous fluids in the deep crust. The depth ( 40 km) at which the conductor intersects the slab suggests that the fluids are released by the transition of hydrous basalt to eclogite at upper greenschist facies and higher metamorphic grade. The nose of the mantle wedge has a conductivity consistent with a dry peridotite composition and thermal models of the system. At a depth of around 80 km the mantle intersecting the slab shows a slight increase in conductivity. This increase is not sufficient to require the presence of melt, but a conductor indicative of melt can be inserted into the model at this depth without compromising the fit.
The effect of conductor permeability on electric current transducers
NASA Astrophysics Data System (ADS)
Mirzaei, M.; Ripka, P.; Chirtsov, A.; Kaspar, P.; Vyhnanek, J.
2018-04-01
In this paper, experimental works and theoretical analysis are presented to analyze the influence of the conductor permeability on the precision of yokeless current sensors. The results of finite-element method (FEM) fit well the measured field values around the conductor. Finally we evaluate the difference in magnetic fields distribution around non-magnetic and magnetic conductor. The calculated values show that the permeability of the ferromagnetic conductor significally affects the reading of the electric current sensors even at DC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lebouc, L.; Marmignon, J.
1983-03-29
A cable for prospecting, said cable including a core of conductor wires surrounded by insulating material and by armour formed by at least one layer of helically wound steel wires. It includes, from its center to its periphery, inside the armour, an axial monofilament made of a polymer that withstands high temperatures, said monofilament forming the insulation of an inner conductor, an outer conductor and a sheath made of a thermoplastic substance that withstands high temperatures, said inner conductor serving a different electrical function than said core of conductor wires.
2004-01-24
Engineers and technicians in the control room at the Dryden Flight Research Center must constantly monitor critical operations and checks during research projects like NASA's hypersonic X-43A. Visible in the photo, taken two days before the X-43's captive carry flight in January 2004, are [foreground to background]; Tony Kawano (Range Safety Officer), Brad Neal (Mission Controller), and Griffin Corpening (Test Conductor).
Jones, Edmund; Masconi, Katya L.; Sweeting, Michael J.; Thompson, Simon G.; Powell, Janet T.
2018-01-01
Markov models are often used to evaluate the cost-effectiveness of new healthcare interventions but they are sometimes not flexible enough to allow accurate modeling or investigation of alternative scenarios and policies. A Markov model previously demonstrated that a one-off invitation to screening for abdominal aortic aneurysm (AAA) for men aged 65 y in the UK and subsequent follow-up of identified AAAs was likely to be highly cost-effective at thresholds commonly adopted in the UK (£20,000 to £30,000 per quality adjusted life-year). However, new evidence has emerged and the decision problem has evolved to include exploration of the circumstances under which AAA screening may be cost-effective, which the Markov model is not easily able to address. A new model to handle this more complex decision problem was needed, and the case of AAA screening thus provides an illustration of the relative merits of Markov models and discrete event simulation (DES) models. An individual-level DES model was built using the R programming language to reflect possible events and pathways of individuals invited to screening v. those not invited. The model was validated against key events and cost-effectiveness, as observed in a large, randomized trial. Different screening protocol scenarios were investigated to demonstrate the flexibility of the DES. The case of AAA screening highlights the benefits of DES, particularly in the context of screening studies.
Tokarz, Richard D.
1983-01-01
A temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles.
Cryogenic vacuumm RF feedthrough device
Wu, Genfa [Yorktown, VA; Phillips, Harry Lawrence [Hayes, VA
2008-12-30
A cryogenic vacuum rf feedthrough device comprising: 1) a probe for insertion into a particle beam; 2) a coaxial cable comprising an inner conductor and an outer conductor, a dielectric/insulating layer surrounding the inner conductor, the latter being connected to the probe for the transmission of higher mode rf energy from the probe; and 3) a high thermal conductivity stub attached to the coaxial dielectric about and in thermal contact with the inner conductor which high thermal conductivity stub transmits heat generated in the vicinity of the probe efficiently and radially from the area of the probe and inner conductor all while maintaining useful rf transmission line characteristics between the inner and outer coaxial conductors.
Multiwire conductor having greatly increased interwire resistance and method for making same
Luhman, T.; Suenaga, M.
1982-03-15
An improved multiwire conductor of the type which is mechanically stabilized by a tin based solder filler is described. A solder filled conductor is heated to a temperature above its melting point for a period long enough to allow a substantial amount of copper to be dissolved from the wires comprising the conductor. The copper forms the brittle intermetallic compound Cu/sub 5/Sn/sub 6/ with tin in the solder. After cooling the conductor is flexed causing a random cracking of the solder, and thereby increasing the interwire resistance of the conductor. The subject invention is particularly adapted for use with braided, ribbon-type solder filled superconductors.
Electron launching voltage monitor
Mendel, Clifford W.; Savage, Mark E.
1992-01-01
An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors.
Unsplit bipolar pulse forming line
Rhodes, Mark A [Pleasanton, CA
2011-05-24
A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.
NASA Astrophysics Data System (ADS)
Nijhuis, A.; van Lanen, E. P. A.; Rolando, G.
2012-01-01
The ITER cable-in-conduit conductors (CICCs) are built up from sub-cable bundles, wound in different stages, which are twisted to counter coupling loss caused by time-changing external magnet fields. The selection of the twist pitch lengths has major implications for the performance of the cable in the case of strain-sensitive superconductors, i.e. Nb3Sn, as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. At present, this is a great challenge for the ITER central solenoid (CS) CICCs and the solution presented here could be a breakthrough for not only the ITER CS but also for CICC applications in general. After proposing longer twist pitches in 2006 and successful confirmation by short sample tests later on, the ITER toroidal field (TF) conductor cable pattern was improved accordingly. As the restrictions for coupling loss are more demanding for the CS conductors than for the TF conductors, it was believed that longer pitches would not be applicable for the conductors in the CS coils. In this paper we explain how, with the use of the TEMLOP model and the newly developed models JackPot-ACDC and CORD, the design of a CICC can be improved appreciably, particularly for the CS conductor layout. For the first time a large improvement is predicted not only providing very low sensitivity to electromagnetic load and thermal axial cable stress variations but at the same time much lower AC coupling loss. Reduction of the transverse load and warm-up-cool-down degradation can be reached by applying longer twist pitches in a particular sequence for the sub-stages, offering a large cable transverse stiffness, adequate axial flexibility and maximum allowed lateral strand support. Analysis of short sample (TF conductor) data reveals that increasing the twist pitch can lead to a gain of the effective axial compressive strain of more than 0.3% with practically no degradation from bending. This is probably explained by the distinct difference in mechanical response of the cable during axial contraction for short and long pitches. For short pitches periodic bending in different directions with relatively short wavelength is imposed because of a lack of sufficient lateral restraint of radial pressure. This can lead to high bending strain and eventually buckling. Whereas for cables with long twist pitches, the strands are only able to react as coherent bundles, being tightly supported by the surrounding strands, providing sufficient lateral restraint of radial pressure in combination with enough slippage to avoid single strand bending along detrimental short wavelengths. Experimental evidence of good performance was already provided with the test of the long pitch TFPRO2-OST2, which is still until today, the best ITER-type cable to strand performance ever without any cyclic load (electromagnetic and thermal contraction) degradation. For reduction of the coupling loss, specific choices of the cabling twist sequence are needed to minimize the area of linked strands and bundles that are coupled and form loops with the applied changing magnetic field, instead of simply avoiding longer pitches. In addition we recommend increasing the wrap coverage of the CS conductor from 50% to at least 70%. A larger wrap coverage fraction enhances the overall strand bundle lateral restraint. The long pitch design seems the best solution to optimize the ITER CS conductor within the given restrictions of the present coil design envelope, only allowing marginal changes. The models predict significant improvement against strain sensitivity and substantial decrease of the AC coupling loss in Nb3Sn CICCs, but also for NbTi CICCs minimization of the coupling loss can obviously be achieved. Although the success of long pitches to transverse load degradation was already demonstrated, the prediction of the elegant innovative combination with low coupling loss needs to be validated by a short sample test.
30 CFR 75.804 - Underground high-voltage cables.
Code of Federal Regulations, 2010 CFR
2010-07-01
... grounded systems shall be equipped with metallic shields around each power conductor with one or more ground conductors having a total cross sectional area of not less than one-half the power conductor, and with an insulated external conductor not smaller than No. 8 (A.W.G.) or an insulated internal ground...
30 CFR 75.804 - Underground high-voltage cables.
Code of Federal Regulations, 2011 CFR
2011-07-01
... grounded systems shall be equipped with metallic shields around each power conductor with one or more ground conductors having a total cross sectional area of not less than one-half the power conductor, and with an insulated external conductor not smaller than No. 8 (A.W.G.) or an insulated internal ground...
Yakymyshyn, Christopher Paul; Brubaker, Michael Allen; Yakymyshyn, Pamela Jane
2007-01-16
A current sensor is described that uses a plurality of magnetic field sensors positioned around a current carrying conductor. The sensor can be hinged to allow clamping to a conductor. The current sensor provides high measurement accuracy for both DC and AC currents, and is substantially immune to the effects of temperature, conductor position, nearby current carrying conductors and aging.
46 CFR 111.60-4 - Minimum cable conductor size.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...
46 CFR 111.60-4 - Minimum cable conductor size.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...
46 CFR 111.60-4 - Minimum cable conductor size.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...
Tremblay, Paul L [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID
2010-09-28
A device and method for altering the line reactance of a transmission line having a transmission line, a first floating conductor and a grounding (shielding) conductor. The first floating conductor is positioned between and electrically insulated from the transmission line and the grounding conductor. A source and a load are connected at opposite ends of the transmission line.
66. DETAIL OF LAUNCH CONDUCTOR AND ASSISTANT LAUNCH CONDUCTOR PANELS ...
66. DETAIL OF LAUNCH CONDUCTOR AND ASSISTANT LAUNCH CONDUCTOR PANELS IN CONSOLE LOCATED CENTRALLY IN SLC-3E CONTROL ROOM. FROM LEFT TO RIGHT IN BACKGROUND: LAUNCH OPERATOR, LAUNCH ANALYST, AND FACILITIES PANELS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Method of making and structure for monolithic optical circuits
NASA Technical Reports Server (NTRS)
Evanchuk, Vincent L. (Inventor)
1983-01-01
A method for making monolithic optical circuits, with related optical devices as required or desired, on a supporting surface (10) consists of coating the supporting surface with reflecting metal or cladding resin, spreading a layer of liquid radiation senstivie plastic (12) on the surface, exposing the liquid plastic with a mask (14) to cure it in a desired pattern of light conductors (16, 18, 20), washing away the unexposed liquid plastic, and coating the conductors thus formed with reflective metal or cladding resin. The index of refraction for the cladding (22) is selected to be lower than for the conductors so that light in the conductors will be reflected by the interface with the cladding. For multiple level conductors, as where one conductor must cross over another, the process may be repeated to fabricate a bridge with columns (24, 26) of conductors to the next level, and conductor (28) between the columns. For more efficient transfer of energy over the bridge, faces at 45.degree. may be formed to reflect light up and across the bridge.
Progressing in cable-in-conduit for fusion magnets: from ITER to low cost, high performance DEMO
NASA Astrophysics Data System (ADS)
Uglietti, D.; Sedlak, K.; Wesche, R.; Bruzzone, P.; Muzzi, L.; della Corte, A.
2018-05-01
The performance of ITER toroidal field (TF) conductors still have a significant margin for improvement because the effective strain between ‑0.62% and ‑0.95% limits the strands’ critical current between 15% and 45% of the maximum achievable. Prototype Nb3Sn cable-in-conduit conductors have been designed, manufactured and tested in the frame of the EUROfusion DEMO activities. In these conductors the effective strain has shown a clear improvement with respect to the ITER conductors, reaching values between ‑0.55% and ‑0.28%, resulting in a strand critical current which is two to three times higher than in ITER conductors. In terms of the amount of Nb3Sn strand required for the construction of the DEMO TF magnet system, such improvement may lead to a reduction of at least a factor of two with respect to a similar magnet built with ITER type conductors; a further saving of Nb3Sn is possible if graded conductors/windings are employed. In the best case the DEMO TF magnet could require fewer Nb3Sn strands than the ITER one, despite the larger size of DEMO. Moreover high performance conductors could be operated at higher fields than ITER TF conductors, enabling the construction of low cost, compact, high field tokamaks.
Fishing anti(lymph)angiogenic drugs with zebrafish.
García-Caballero, Melissa; Quesada, Ana R; Medina, Miguel A; Marí-Beffa, Manuel
2018-02-01
Zebrafish, an amenable small teleost fish with a complex mammal-like circulatory system, is being increasingly used for drug screening and toxicity studies. It combines the biological complexity of in vivo models with a higher-throughput screening capability compared with other available animal models. Externally growing, transparent embryos, displaying well-defined blood and lymphatic vessels, allow the inexpensive, rapid, and automatable evaluation of drug candidates that are able to inhibit neovascularisation. Here, we briefly review zebrafish as a model for the screening of anti(lymph)angiogenic drugs, with emphasis on the advantages and limitations of the different zebrafish-based in vivo assays. Copyright © 2017 Elsevier Ltd. All rights reserved.
Whittington, Melanie D; Atherly, Adam J; Curtis, Donna J; Lindrooth, Richard C; Bradley, Cathy J; Campbell, Jonathan D
2017-08-01
Patients in the ICU are at the greatest risk of contracting healthcare-associated infections like methicillin-resistant Staphylococcus aureus. This study calculates the cost-effectiveness of methicillin-resistant S aureus prevention strategies and recommends specific strategies based on screening test implementation. A cost-effectiveness analysis using a Markov model from the hospital perspective was conducted to determine if the implementation costs of methicillin-resistant S aureus prevention strategies are justified by associated reductions in methicillin-resistant S aureus infections and improvements in quality-adjusted life years. Univariate and probabilistic sensitivity analyses determined the influence of input variation on the cost-effectiveness. ICU. Hypothetical cohort of adults admitted to the ICU. Three prevention strategies were evaluated, including universal decolonization, targeted decolonization, and screening and isolation. Because prevention strategies have a screening component, the screening test in the model was varied to reflect commonly used screening test categories, including conventional culture, chromogenic agar, and polymerase chain reaction. Universal and targeted decolonization are less costly and more effective than screening and isolation. This is consistent for all screening tests. When compared with targeted decolonization, universal decolonization is cost-saving to cost-effective, with maximum cost savings occurring when a hospital uses more expensive screening tests like polymerase chain reaction. Results were robust to sensitivity analyses. As compared with screening and isolation, the current standard practice in ICUs, targeted decolonization, and universal decolonization are less costly and more effective. This supports updating the standard practice to a decolonization approach.
Kim, Ki Joon
2014-01-01
Abstract This study explores the psychological effects of screen size on smartphone adoption by proposing an extended Technology Acceptance Model (TAM) that integrates an empirical comparison between large and small screens with perceived control, affective quality, and the original TAM constructs. A structural equation modeling analysis was conducted on data collected from a between-subjects experiment (N=130) in which users performed a web-based task on a smartphone with either a large (5.3 inches) or a small (3.7 inches) screen. Results show that a large screen, compared to a small screen, is likely to lead to higher smartphone adoption by simultaneously promoting both the utilitarian and hedonic qualities of smartphones, which in turn positively influence perceived ease of use of—and attitude toward—the device respectively. Implications and directions for future research are discussed. PMID:24694112
Kim, Ki Joon; Sundar, S Shyam
2014-07-01
This study explores the psychological effects of screen size on smartphone adoption by proposing an extended Technology Acceptance Model (TAM) that integrates an empirical comparison between large and small screens with perceived control, affective quality, and the original TAM constructs. A structural equation modeling analysis was conducted on data collected from a between-subjects experiment (N=130) in which users performed a web-based task on a smartphone with either a large (5.3 inches) or a small (3.7 inches) screen. Results show that a large screen, compared to a small screen, is likely to lead to higher smartphone adoption by simultaneously promoting both the utilitarian and hedonic qualities of smartphones, which in turn positively influence perceived ease of use of-and attitude toward-the device respectively. Implications and directions for future research are discussed.
Fractional power-law spatial dispersion in electrodynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tarasov, Vasily E., E-mail: tarasov@theory.sinp.msu.ru; Departamento de Análisis Matemático, Universidad de La Laguna, 38271 La Laguna, Tenerife; Trujillo, Juan J., E-mail: jtrujill@ullmat.es
2013-07-15
Electric fields in non-local media with power-law spatial dispersion are discussed. Equations involving a fractional Laplacian in the Riesz form that describe the electric fields in such non-local media are studied. The generalizations of Coulomb’s law and Debye’s screening for power-law non-local media are characterized. We consider simple models with anomalous behavior of plasma-like media with power-law spatial dispersions. The suggested fractional differential models for these plasma-like media are discussed to describe non-local properties of power-law type. -- Highlights: •Plasma-like non-local media with power-law spatial dispersion. •Fractional differential equations for electric fields in the media. •The generalizations of Coulomb’s lawmore » and Debye’s screening for the media.« less
Electrostatic MEMS devices with high reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldsmith, Charles L; Auciello, Orlando H; Sumant, Anirudha V
The present invention provides for an electrostatic microelectromechanical (MEMS) device comprising a dielectric layer separating a first conductor and a second conductor. The first conductor is moveable towards the second conductor, when a voltage is applied to the MEMS device. The dielectric layer recovers from dielectric charging failure almost immediately upon removal of the voltage from the MEMS device.
33 CFR 183.430 - Conductors in circuits of less than 50 volts.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Conductors in circuits of less... Requirements § 183.430 Conductors in circuits of less than 50 volts. (a) Each conductor in a circuit that has a... Standard 1128. (b) This section does not apply to communication systems; electronic navigation equipment...
33 CFR 183.430 - Conductors in circuits of less than 50 volts.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Conductors in circuits of less... Requirements § 183.430 Conductors in circuits of less than 50 volts. (a) Each conductor in a circuit that has a... Standard 1128. (b) This section does not apply to communication systems; electronic navigation equipment...
33 CFR 183.430 - Conductors in circuits of less than 50 volts.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Conductors in circuits of less... Requirements § 183.430 Conductors in circuits of less than 50 volts. (a) Each conductor in a circuit that has a... Standard 1128. (b) This section does not apply to communication systems; electronic navigation equipment...
33 CFR 183.430 - Conductors in circuits of less than 50 volts.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Conductors in circuits of less... Requirements § 183.430 Conductors in circuits of less than 50 volts. (a) Each conductor in a circuit that has a... Standard 1128. (b) This section does not apply to communication systems; electronic navigation equipment...
33 CFR 183.430 - Conductors in circuits of less than 50 volts.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Conductors in circuits of less... Requirements § 183.430 Conductors in circuits of less than 50 volts. (a) Each conductor in a circuit that has a... Standard 1128. (b) This section does not apply to communication systems; electronic navigation equipment...
Convectively cooled electrical grid structure
Paterson, J.A.; Koehler, G.W.
1980-11-10
Undesirable distortions of electrical grid conductors from thermal cycling are minimized and related problems such as unwanted thermionic emission and structural failure from overheating are avoided by providing for a flow of fluid coolant within each conductor. The conductors are secured at each end to separate flexible support elements which accommodate to individual longitudinal expansion and contraction of each conductor while resisting lateral displacements, the coolant flow preferably being directed into and out of each conductor through passages in the flexible support elements. The grid may have a modular or divided construction which facilitates manufacture and repairs.
Temperature limited heaters using phase transformation of ferromagnetic material
Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN
2009-10-06
Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.
Tokarz, Richard D.
1982-01-01
A liquid level sensor having a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.
High temperature superconducting composite conductor and method for manufacturing the same
Holesinger, Terry G.; Bingert, John F.
2002-01-01
A high temperature superconducting composite conductor is provided including a high temperature superconducting material surrounded by a noble metal layer, the high temperature superconducting composite conductor characterized as having a fill factor of greater than about 40. Additionally, the conductor can be further characterized as containing multiple cores of high temperature superconducting material surrounded by a noble metal layer, said multiple cores characterized as having substantially uniform geometry in the cross-sectional dimensions. Processes of forming such a high temperature superconducting composite conductor are also provided.
Not Available
1981-01-29
Aliquid level sensor is described which has a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.
Electron launching voltage monitor
Mendel, C.W.; Savage, M.E.
1992-03-17
An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.
75 FR 69165 - Conductor Certification
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
...FRA proposes to prescribe regulations for certification of conductors, as required by the Rail Safety Improvement Act of 2008. The proposed rule would require railroads to have a formal program for certifying conductors. As part of that program, railroads would be required to have a formal process for training prospective conductors and determining that all persons are competent before permitting them to serve as a conductor. FRA is proposing this regulation to ensure that only those persons who meet minimum Federal safety standards serve as conductors, to reduce the rate and number of accidents and incidents, and to improve railroad safety. Although this NPRM does not propose any specific amendments to the regulation governing locomotive engineer certification, it does highlight areas in that regulation that may require conforming changes.
Non-local electron transport through normal and topological ladder-like atomic systems
NASA Astrophysics Data System (ADS)
Kurzyna, Marcin; Kwapiński, Tomasz
2018-05-01
We propose a locally protected ladder-like atomic system (nanoconductor) on a substrate that is insensitive to external perturbations. The system corresponds to coupled atomic chains fabricated on different surfaces. Electron transport properties of such conductors are studied theoretically using the model tight-binding Su-Schriffer-Hegger (SSH) Hamiltonian and Green's function formalism. We have found that the conductance of the system is almost insensitive to single adatoms and oscillates as a function of the side chain length with very large periods. Non-local character of the electron transport was observed also for topological SSH chains where nontrivial end states survive in the presence of disturbances as well as for different substrates. We have found that the careful inspection of the density of states or charge waves can provide the information about the atom energy levels and hopping amplitudes. Moreover, the ladder-like geometry allows one to distinguish between normal and topological zero-energy states. It is important that topological chains do not reveal Friedel oscillations which are observed in non-topological chains.
Gravitational anti-screening as an alternative to dark matter
NASA Astrophysics Data System (ADS)
Penner, A. Raymond
2016-04-01
A semiclassical model of the screening of electric charge by virtual electric dipoles, as found in electrodynamic theory, will be presented. This model is then applied to the hypothetical case of an electric force where like charges attract. The resulting anti-screening of the electric charge is found to have the same functional dependence on the field source and observation distance that is found with the Baryonic Tully-Fisher Relationship. This leads to an anti-screening model for the gravitational force which is then used to determine the theoretical rotational curve of the Galaxy and the theoretical velocity dispersions and shear values for the Coma cluster. These theoretical results are found to be in good agreement with the corresponding astronomical observations. The screening of electric charge as found in QED and the larger apparent masses of galaxies and galactic clusters therefore appears to be two sides of the same coin.
A model for phase evolution and volume expansion in tube type Nb3Sn conductors
NASA Astrophysics Data System (ADS)
Xu, X.; Sumption, M. D.; Collings, E. W.
2013-12-01
In this work, an analytic model for phase formation and volume expansion during heat treatment in tube type Nb3Sn strands is presented. Tube type Nb3Sn conductors consist of Nb or Nb-Ta alloy tube with a simple Cu/Sn binary metal insert to form the basic subelement (filament). A number of these elements, each with an outer Cu jacket, are restacked to form a multifilamentary strand. The present tube type conductors, with 4.2 K, 12 T non-Cu critical current density (Jc) in the 2000-2500 A mm-2 range and effective subelement diameters (deff) in the 12-36 μm range, are of interest for a number of applications. During the reaction of typical tube type strands, the Sn-Cu becomes molten and reacts with the Nb tube first to form NbSn2, then Nb6Sn5. At later times in the reaction sequence, all of the NbSn2 and Nb6Sn5 is converted to Nb3Sn. Some of the Nb3Sn is formed by a Nb-Sn reaction and has a fine grain (FG) structure, while some is converted from Nb6Sn5, which results in a coarse grain (CG) region. The fractions of FG and CG A15 are important in determining the final conductor properties. In this work we develop an analytic model to predict the radial extents of the various phases, and in particular the final FG and CG fractions based on the starting Nb, Cu, and Sn amounts in the subelements. The model is then compared to experimental results and seen to give reasonable agreement. By virtue of this model we outline an approach to minimize the CG regions in tube type and PIT strands and maximize the final FG area fractions. Furthermore, the volume change during the various reaction stages was also studied. It is proposed that the Sn content in the Cu-Sn alloy has a crucial influence on the radial expansion.
Perceived Benefits and Barriers of Cervical Cancer Screening Among Chinese American Women.
Tung, Wei-Chen; Lu, Minggen; Granner, Michelle
2017-03-01
To explore the perceived benefits and barriers to cervical cancer screening among Chinese American women using stages of the Transtheoretical Model of Change. . Cross-sectional design with self-report surveys. . Chinese communities (e.g., churches, supermarkets, restaurants) in Northern California and Northern Nevada. . 121 Chinese women aged 21-65 years living in Northern California and Northern Nevada. . A snowball sampling technique using personal contacts was used. . Stages of change and perceived benefits and barriers to cervical cancer screening. . Participants in the action/maintenance stage were most likely to believe that cervical cancer was treatable if caught early. Women in the contemplation/preparation stage were more likely to state that they worried about or feared screening, that it was too expensive, and that they would want to use Chinese medicine to cure an illness before trying Western medicine. Women in the precontemplation/relapse stage were most likely to report that they did not know where to get screened and that their partner would not want them to be screened. . Perceived benefits and barriers to screening were differentially associated with the stages of change. Results may support culturally sensitive and theory-based programs to improve screening rates among Chinese American women. . The results suggest the importance of cultural sensitivity among nursing providers when working with Chinese Americans to provide more relevant, holistic care.
Research on the Test of Transmission Line Galloping
NASA Astrophysics Data System (ADS)
Zhang, Lichun; Li, Qing; lv, Zhongbin; Ji, Kunpeng; Liu, Bin
2018-03-01
The load of iced transmission line and the load generated by galloping after the conductor are covered by ice all may cause severe circuit faults, such as tripping, conductor breaking, armor clamp damage and even tower collapse, thus severely threatening running safety of power system. The generation and development processes of galloping of power transmission line is very complicated, and numerous factors may influence the galloping excitation, such as environmental factors, terrain factors and structural parameters of power transmission line; in which, the ice covering of conductor is one of necessary factors causing galloping. Therefore, researches on ice covering increasing test of different types of conductors under different meteorological conditions have been conducted in large-sized multi-functional phytotron, thus obtaining the relation curve of ice covering increasing of conductor along with time under different conditions, and analyzing factors influencing increasing of ice covering. The research result shows that under the same ice covering conditions, the increasing of ice covering of conductor with small diameter is relatively rapid; both environmental temperature and wind speed have obvious influence on increasing of ice covering of conductor, and the environmental temperature will decide the type of ice covering of conductor surface. Meanwhile, after wind tunnel tests targeting conductors with different ice covering shapes, pneumatic stability loss characteristics of conductors with different ice shapes have been obtained. Research results have important scientific reference value for revealing the mechanism of galloping of iced power transmission line, and have relatively high engineering practicability value for promoting realization of early warning system for galloping of iced power transmission line.
Assessment of the noise annoyance among subway train conductors in Tehran, Iran.
Hamidi, Mansoureh; Kavousi, Amir; Zaheri, Somayeh; Hamadani, Abolfazl; Mirkazemi, Roksana
2014-01-01
Subway transportation system is a new phenomenon in Iran. Noise annoyance interferes with the individual's task performance, and the required alertness in the driving of subway trains. This is the first study conducted to measure the level of noise and noise annoyance among conductors of subway organization in Tehran, Iran. This cross sectional study was conducted among 167 randomly selected train conductors. Information related to noise annoyance was collected by using a self-administered questionnaire. The dosimetry and sound metering was done for the conductors and inside the cabins. There were 41 sound metering measuring samples inside the conductors' cabin, and there were 12 samples of conductors' noise exposure. The results of sound level meter showed that the mean Leq was 73.0 dBA ± 8.7 dBA and the dosimetry mean measured Leq was 82.1 dBA ± 6.8 dBA. 80% of conductors were very annoyed/annoyed by noise in their work place. 53.9% of conductors reported that noise affected their work performance and 63.5% reported that noise causes that they lose their concentration. The noise related to movement of train wheels on rail was reported as the worst by 83.2% followed by the noise of brakes (74.3%) and the ventilation noise (71.9%). 56.9% of conductors reported that they are suffering from sleeplessness, 40.1% from tinnitus and 80.2% feeling fatigue and sleepy. The study results showed the high level of noise and noise annoyance among train conductors and the poor health outcome of their exposure to this level of noise.
Electrical anisotropy in the presence of oceans—a sensitivity study
NASA Astrophysics Data System (ADS)
Cembrowski, Marcel; Junge, Andreas
2018-05-01
Electrical anisotropy in the presence of oceans is particularly relevant at continent-ocean subduction zones (e.g. Cascadian and Andean Margin), where seismic anisotropy has been found with trench-parallel or perpendicular fast direction. The identification of electrical anisotropy at such locations sheds new light on the relation between seismic and electrical anisotropies. At areas confined by two opposite oceans, for example the Pyrenean Area and Central America, we demonstrate that the superposed responses of both oceans generate a uniform and large phase split of the main phase tensor axes. The pattern of the tipper arrows is comparatively complicated and it is often difficult to associate their length and orientation to the coast effect. On the basis of simple forward models involving opposite oceans and anisotropic layers, we show that both structures generate similar responses. In the case of a deep anisotropic layer, the resistivity and phase split generated by the oceans alone will be increased or decreased depending on the azimuth of the conducting horizontal principal axes. The 3-D isotropic inversion of the anisotropic forward responses reproduces the input data reasonably well. The anisotropy is explained by large opposed conductors outside the station grid and by tube-like elongated conductors representing a macroscopic anisotropy. If the conductive direction is perpendicular to the shorelines, the anisotropy is not recovered by 3-D isotropic inversion.
Graham, M.H.
1962-09-18
A barrier-grid storage tube and an improved means for writing and reading of information in such a tube are described. A triax cable is provided in the reading and writing circuit and includes a coiled portion. The inner conductor of the cable is connected to the back plate of the barrier grid target assembly of the storage tube, the middle conductor of the cable is connected to a shielding member encompassing the target assembly and this member supports the barrier grid of the assembly, and the outer conductor of the cable is connected to an external shreld surrounding the target assembly. A source of writing sr- gnals is connected between the rnner conductor and middle conductor of said cable. Both the middle and outer conductors are connected to ground at the source end, and a small trimmer condenser is connected between the external shield and the source end of the inner conductor of the cable to compensate for the direct back plate-to-ground capacity due to the imperfect shielding of the barrier grid. The coiled portion of the cable provides for an output signal to a secondary corl coupled thereto. The grounded outer conductor serves as a means for preventing an output signal being applied to the coiled portion of the cable on application of writing signals to the inner and middle conductors of the cable. (AEC)
One-Dimensional Harmonic Model for Biomolecules
Krizan, John E.
1973-01-01
Following in spirit a paper by Rosen, we propose a one-dimensional harmonic model for biomolecules. Energy bands with gaps of the order of semi-conductor gaps are found. The method is discussed for general symmetric and periodic potential functions. PMID:4709518
Variable-Resistivity Material For Memory Circuits
NASA Technical Reports Server (NTRS)
Nagasubramanian, Ganesan; Distefano, Salvador; Moacanin, Jovan
1989-01-01
Nonvolatile memory elements packed densely. Electrically-erasable, programmable, read-only memory matrices made with newly-synthesized organic material of variable electrical resistivity. Material, polypyrrole doped with tetracyanoquinhydrone (TCNQ), changes reversibly between insulating or higher-resistivity state and conducting or low-resistivity state. Thin film of conductive polymer separates layer of row conductors from layer of column conductors. Resistivity of film at each intersection and, therefore, resistance of memory element defined by row and column, increased or decreased by application of suitable switching voltage. Matrix circuits made with this material useful for experiments in associative electronic memories based on models of neural networks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campione, Salvatore; Warne, Larry K.; Schiek, Richard
2017-09-01
This report details the modeling results for the response of a finite-length dissipative conductor interacting with a conducting ground to a hypothetical nuclear device with the same output energy spectrum as the Fat Man device. We use a time-domain method based on transmission line theory that allows accounting for time-varying air conductivities. We implemented such method in a code we call ATLOG - Analytic Transmission Line Over Ground. Results are compared the frequency-domain version of ATLOG previously developed and to the circuit simulator Xyce in some instances. Intentionally Left Blank
ERIC Educational Resources Information Center
Nápoles, Jessica; Silvey, Brian A.
2017-01-01
The purpose of this study was to examine participants' (college band and choral musicians, N = 143) perceptions of conductor clarity and expressivity after viewing band and choral directors conducting with or without a baton. One band and one choral conductor each prepared and conducted two excerpts of Guy Forbes's "O Nata Lux", a piece…
High conductivity composite metal
Zhou, Ruoyi; Smith, James L.; Embury, John David
1998-01-01
Electrical conductors and methods of producing them, where the conductors possess both high strength and high conductivity. Conductors are comprised of carbon steel and a material chosen from a group consisting of copper, nickel, silver, and gold. Diffusion barriers are placed between these two materials. The components of a conductor are assembled and then the assembly is subjected to heat treating and mechanical deformation steps.
Microminiature coaxial cable and methods manufacture
Bongianni, Wayne L.
1986-01-01
A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.
Microminiature coaxial cable and method of manufacture
Bongianni, W.L.
1989-03-28
A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.
Microminiature coaxial cable and method of manufacture
Bongianni, Wayne L.
1989-01-01
A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.
Microminiature coaxial cable and methods of manufacture
Bongianni, W.L.
1983-12-29
A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 ..mu..m thick and from 150 to 200 ..mu..m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dieleectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.
Microminiature coaxial cable and methods manufacture
Bongianni, W.L.
1986-04-08
A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.
NASA Astrophysics Data System (ADS)
Sang, Lina; Gutiérrez, Joffre; Cai, Chuanbing; Dou, Shixue; Wang, Xiaolin
2018-07-01
We report on the effect of in situ hydrostatic pressure on the enhancement of the in-magnetic-field critical current density parallel to the crystallographic c-axis and vortex pinning in epitaxial Y(Dy0.5)Ba2Cu3O7‑δ coated conductors prepared by metal organic deposition. Our results show that in situ hydrostatic pressure greatly enhances the critical current density at high fields and high temperatures. At 80 K and 5 T we observe a ten-fold increase in the critical current density under the pressure of 1.2 GPa, and the irreversibility line is shifted to higher fields without changing the critical temperature. The normalized magnetic relaxation rate shows that vortex creep rates are strongly suppressed due to applied pressure, and the pinning energy is significantly increased based on the collective creep theory. After releasing the pressure, we recover the original superconducting properties. Therefore, we speculate that the in situ hydrostatic pressure exerted on the coated conductor enhances the pinning of existing extended defects. This is totally different from what has been observed in REBa2Cu3O7‑δ melt-textured crystals, where the effect of pressure generates point-like defects.
Superconducting energy storage magnet
NASA Technical Reports Server (NTRS)
Boom, Roger W. (Inventor); Eyssa, Yehia M. (Inventor); Abdelsalam, Mostafa K. (Inventor); Huang, Xianrui (Inventor)
1993-01-01
A superconducting magnet is formed having composite conductors arrayed in coils having turns which lie on a surface defining substantially a frustum of a cone. The conical angle with respect to the central axis is preferably selected such that the magnetic pressure on the coil at the widest portion of the cone is substantially zero. The magnet structure is adapted for use as an energy storage magnet mounted in an earthen trench or tunnel where the strength the surrounding soil is lower at the top of the trench or tunnel than at the bottom. The composite conductor may be formed having a ripple shape to minimize stresses during charge up and discharge and has a shape for each ripple selected such that the conductor undergoes a minimum amount of bending during the charge and discharge cycle. By minimizing bending, the working of the normal conductor in the composite conductor is minimized, thereby reducing the increase in resistance of the normal conductor that occurs over time as the conductor undergoes bending during numerous charge and discharge cycles.
Gullate, Mary
2006-01-01
African American women (AAW) are 25% more likely to present with late stage breast cancer and 20% more likely to die from their disease than Caucasian women. Researchers report that a treatment delay of 3 months is a significant factor in breast cancer mortality. Socioeconomic factors, lack of access and knowledge, spiritual and religious beliefs, fear and fatalism are reported as contributing factors to screening delays. Studies have primarily applied the Health Belief Model (HBM) and modified versions like the Champion HBM to preventive health practices. Neither have significant inclusion of spirituality or religiosity. The TRA/TPB focus on beliefs, intent and attitude as individual determinants of the likelihood of performing a specific behavior; but have not had wide utility in studies related to screening delays among AAW. This paper explores the utility of applying the TRA/TPB as the theoretical framework for determining cultural relevance of spirituality and religiosity to screening delays among AAW.
Klein, Jonathan D; Handwerker, Lisa; Sesselberg, Tracy S; Sutter, Erika; Flanagan, Erinn; Gawronski, Beth
2007-08-01
To evaluate whether quality of care provided to adolescents enrolled in a community-based managed care plan was better for those who also received some care at school-based health centers (SBHCs). The Young Adult Health Care Survey (YAHCS) was administered to 374 adolescents (commercially insured, Medicaid-insured, and SBHC users) to assess risk behaviors, provision of preventive screening and counseling, and quality of care. SBHC users were most likely to report that their provider told them their discussions were confidential, and that they received screening/counseling on sexually transmitted diseases (STDs), HIV/AIDS, condom use, and birth control. Commercially insured adolescents were least likely to report discussion of sexual health issues. SBHC users had the highest mean YAHCS quality measure scores for screening/counseling on pregnancy/STDs, diet and exercise, and helpfulness of counseling provided; Medicaid-insured teens had the lowest scores on four of seven measures. Regression models controlled for demographics, use of screener, and site of care showed that use of a screener had a significant impact on six of seven quality measure models. Younger age predicted screening for risk behaviors; being female, African-American, and an SBHC user predicted screening on pregnancy/STDs. SBHCs may increase adolescents' access to confidential care, and SBHC providers may be more likely than those in other settings to screen and counsel patients about sexual health. Overall quality of preventive care reported by commercially insured adolescents may be better in some health content areas and worse in others compared with care reported by Medicaid-insured youth and SBHC users.
High voltage feedthrough bushing
Brucker, John P.
1993-01-01
A feedthrough bushing for a high voltage diode provides for using compression sealing for all sealing surfaces. A diode assembly includes a central conductor extending through the bushing and a grading ring assembly circumferentially surrounding and coaxial with the central conductor. A flexible conductive plate extends between and compressively seals against the central conductor and the grading ring assembly, wherein the flexibility of the plate allows inner and outer portions of the plate to axially translate for compression sealing against the central conductor and the grading ring assembly, respectively. The inner portion of the plate is bolted to the central conductor for affecting sealing. A compression beam is also bolted to the central conductor and engages the outer portion of the plate to urge the outer portion toward the grading ring assembly to obtain compression sealing therebetween.
Computational quench model applicable to the SMES/CICC
NASA Astrophysics Data System (ADS)
Luongo, Cesar A.; Chang, Chih-Lien; Partain, Kenneth D.
1994-07-01
A computational quench model accounting for the hydraulic peculiarities of the 200 kA SMES cable-in-conduit conductor has been developed. The model is presented and used to simulate the quench on the SMES-ETM. Conclusions are drawn concerning quench detection and protection. A plan for quench model validation is presented.
NASA Astrophysics Data System (ADS)
Rode, Stefan; Bennett, Robert; Yoshi Buhmann, Stefan
2018-04-01
We discuss the Casimir effect for boundary conditions involving perfect electromagnetic conductors, which interpolate between perfect electric conductors and perfect magnetic conductors. Based on the corresponding reciprocal Green’s tensor we construct the Green’s tensor for two perfectly reflecting plates with magnetoelectric coupling (non-reciprocal media) within the framework of macroscopic quantum electrodynamics. We calculate the Casimir force between two arbitrary perfect electromagnetic conductor plates, resulting in a universal analytic expression that connects the attractive Casimir force with the repulsive Boyer force. We relate the results to a duality symmetry of electromagnetism.
Conductor requirements for high-temperature superconducting utility power transformers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pleva, E. F.; Mehrotra, V.; Schwenterly, S W
High-temperature superconducting (HTS) coated conductors in utility power transformers must satisfy a set of operating requirements that are driven by two major considerations-HTS transformers must be economically competitive with conventional units, and the conductor must be robust enough to be used in a commercial manufacturing environment. The transformer design and manufacturing process will be described in order to highlight the various requirements that it imposes on the HTS conductor. Spreadsheet estimates of HTS transformer costs allow estimates of the conductor cost required for an HTS transformer to be competitive with a similarly performing conventional unit.
Formation of 2D nanoparticles with block structure in simultaneous electric explosion of conductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kryzhevich, Dmitrij S., E-mail: kryzhev@ispms.ru, E-mail: kost@ispms.ru; Zolnikov, Konstantin P., E-mail: kryzhev@ispms.ru, E-mail: kost@ispms.ru; Abdrashitov, Andrei V.
2014-11-14
A molecular dynamics simulation of nanoparticle formation in simultaneous electric explosion of conductors is performed. Interatomic interaction is described using potentials calculated in the framework of the embedded atom method. High-rate heating results in failure of the conductors with the formation of nanoparticles. The influence of the heating rate, temperature distribution over the specimen cross-section and the distance between simultaneously exploded conductors on the structure of formed nanoparticles is studied. The calculation results show that the electric explosion of conductors allows the formation of nanoparticles with block structure.
Convectively cooled electrical grid structure
Paterson, James A.; Koehler, Gary W.
1982-01-01
Undesirable distortions of electrical grid conductors (12) from thermal cycling are minimized and related problems such as unwanted thermionic emission and structural failure from overheating are avoided by providing for a flow of fluid coolant within each conductor (12). The conductors (12) are secured at each end to separate flexible support elements (16) which accommodate to individual longitudinal expansion and contraction of each conductor (12) while resisting lateral displacements, the coolant flow preferably being directed into and out of each conductor through passages (48) in the flexible support elements (16). The grid (11) may have a modular or divided construction which facilitates manufacture and repairs.
46 CFR 111.05-37 - Overcurrent devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... devices. (a) A permanently grounded conductor must not have an overcurrent device unless the overcurrent device simultaneously opens each ungrounded conductor of the circuit. (b) The neutral conductor of the...
77 FR 61657 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-10
.... The railroad now requests a similar waiver from the conductor certification regulations for purposes... encourage conductor reporting of close calls and protect conductors and Amtrak from discipline or sanctions...
46 CFR 111.05-37 - Overcurrent devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... devices. (a) A permanently grounded conductor must not have an overcurrent device unless the overcurrent device simultaneously opens each ungrounded conductor of the circuit. (b) The neutral conductor of the...
Gangarapu, Satesh; Marcelis, Antonius T M; Zuilhof, Han
2013-04-02
The pKa of the conjugate acids of alkanolamines, neurotransmitters, alkaloid drugs and nucleotide bases are calculated with density functional methods (B3LYP, M08-HX and M11-L) and ab initio methods (SCS-MP2, G3). Implicit solvent effects are included with a conductor-like polarizable continuum model (CPCM) and universal solvation models (SMD, SM8). G3, SCS-MP2 and M11-L methods coupled with SMD and SM8 solvation models perform well for alkanolamines with mean unsigned errors below 0.20 pKa units, in all cases. Extending this method to the pKa calculation of 35 nitrogen-containing compounds spanning 12 pKa units showed an excellent correlation between experimental and computational pKa values of these 35 amines with the computationally low-cost SM8/M11-L density functional approach. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
46 CFR 111.15-20 - Conductors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-20 Conductors. (a) Each conductor penetration to a battery room must be made watertight. (b) The termination of each cable...
46 CFR 111.15-20 - Conductors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-20 Conductors. (a) Each conductor penetration to a battery room must be made watertight. (b) The termination of each cable...
46 CFR 111.15-20 - Conductors.
Code of Federal Regulations, 2012 CFR
2012-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-20 Conductors. (a) Each conductor penetration to a battery room must be made watertight. (b) The termination of each cable...
46 CFR 111.15-20 - Conductors.
Code of Federal Regulations, 2011 CFR
2011-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-20 Conductors. (a) Each conductor penetration to a battery room must be made watertight. (b) The termination of each cable...
46 CFR 111.15-20 - Conductors.
Code of Federal Regulations, 2014 CFR
2014-10-01
... REQUIREMENTS Storage Batteries and Battery Chargers: Construction and Installation § 111.15-20 Conductors. (a) Each conductor penetration to a battery room must be made watertight. (b) The termination of each cable...
Super-Joule heating in graphene and silver nanowire network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maize, Kerry; Das, Suprem R.; Sadeque, Sajia
Transistors, sensors, and transparent conductors based on randomly assembled nanowire networks rely on multi-component percolation for unique and distinctive applications in flexible electronics, biochemical sensing, and solar cells. While conduction models for 1-D and 1-D/2-D networks have been developed, typically assuming linear electronic transport and self-heating, the model has not been validated by direct high-resolution characterization of coupled electronic pathways and thermal response. In this letter, we show the occurrence of nonlinear “super-Joule” self-heating at the transport bottlenecks in networks of silver nanowires and silver nanowire/single layer graphene hybrid using high resolution thermoreflectance (TR) imaging. TR images at the microscopicmore » self-heating hotspots within nanowire network and nanowire/graphene hybrid network devices with submicron spatial resolution are used to infer electrical current pathways. The results encourage a fundamental reevaluation of transport models for network-based percolating conductors.« less
High conductivity composite metal
Zhou, R.; Smith, J.L.; Embury, J.D.
1998-01-06
Electrical conductors and methods of producing them are disclosed, where the conductors possess both high strength and high conductivity. Conductors are comprised of carbon steel and a material chosen from a group consisting of copper, nickel, silver, and gold. Diffusion barriers are placed between these two materials. The components of a conductor are assembled and then the assembly is subjected to heat treating and mechanical deformation steps. 10 figs.
Detailed characteristics of intermittent current pulses due to positive corona
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yang, E-mail: liuyangwuh520@sina.com; Cui, Xiang; Lu, Tiebing
In order to get detailed characteristics of intermittent current pulses due to positive corona such as the repetition rate of burst-pulse trains, the peak value ratio of the primary pulse to the secondary pulse, the number of pulses per burst, and the interval of the secondary pulses, a systematic study was carried out in a coaxial conductor-cylinder electrode system with the conductor electrode being set with a discharge point. Empirical formulae for the number of pulses per burst and the interval of the secondary pulses are first presented. A theoretical model based on the motion of the space-charge clouds ismore » proposed. Analysis with the model gives explanations to the experimental results and reveals some new insights into the physical mechanism of positive intermittent corona.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... shall be grounded to the ground conductor in the cable. The coupler shall be constructed so that the ground check continuity conductor shall be broken first and the ground conductors shall be broken last...
NASA Astrophysics Data System (ADS)
Jewulski, J. R.; Osif, T. L.; Remick, R. J.
1990-12-01
The purpose of this program was to survey the field of solid-state proton conductors (SSPC), identify conductors that could be used to develop solid-state fuel cells suitable for use with coal derived fuel gases, and begin the experimental research required for the development of these fuel cells. This document covers the following topics: the history of developments and current status of the SSPC, including a review of proton conducting electrolyte structures, the current status of the medium temperature SSPC development, electrodes for moderate temperature (SSPC) fuel cell, basic material and measurement techniques applicable for SSPC development, modeling, and optimization studies. Correlation and optimization studies are described which include correlation studies on proton conduction and oxide cathode optimization for the SSPC fuel cell. Experiments with the SSPC fuel cells are presented which include the fabrication of the electrolyte disks, apparatus for conducting measurements, the strontium-cerium based electrolyte, the barium-cerium based electrolyte with solid foil electrodes, the barium-cerium based electrolyte with porous electrodes, and conduction mechanisms.
Deep electrical resistivity structure of northwestern Costa Rica
NASA Astrophysics Data System (ADS)
Brasse, H.; Kapinos, G.; Mütschard, L.; Alvarado, G. E.; Worzewski, T.; Jegen, M.
2009-01-01
First long-period magnetotelluric investigations were conducted in early 2008 in northwestern Costa Rica, along a profile that extends from the coast of the Pacific Ocean, traverses the volcanic arc and ends currently at the Nicaraguan border. The aim of this study is to gain insight into the electrical resistivity structure and thus fluid distribution at the continental margin where the Cocos plate subducts beneath the Caribbean plate. Preliminary two-dimensional models map the only moderately resistive mafic/ultramafic complexes of the Nicoya Peninsula (resistivity of a few hundred Ωm), the conductive forearc and the backarc basins (several Ωm). Beneath the backarc basin the data image a poor conductor in the basement with a clear termination in the south, which may tentatively be interpreted as the Santa Elena Suture. The volcanic arc shows no pronounced anomaly at depth, but a moderate conductor underlies the backarc with a possible connection to the upper mantle. A conductor at deep-crustal levels in the forearc may reflect fluid release from the downgoing slab.
NASA Astrophysics Data System (ADS)
Belyaev, B. A.; Serzhantov, A. M.; Bal'va, Ya. F.; Leksikov, An. A.; Galeev, R. G.
2015-05-01
A microstrip bandpass filter of new design based on original resonators with an interdigital structure of conductors has been studied. The proposed filters of third to sixth order are distinguished for their high frequency-selective properties and much smaller size than analogs. It is established that a broad stop band, extending up to a sixfold central bandpass frequency, is determined by low unloaded Q of higher resonance mode and weak coupling of resonators in the pass band. It is shown for the first time that, as the spacing of interdigital stripe conductors decreases, the Q of higher resonance mode monotonically drops, while the Q value for the first operating mode remains high. A prototype fourth-order filter with a central frequency of 0.9 GHz manufactured on a ceramic substrate with dielectric permittivity ɛ = 80 has microstrip topology dimensions of 9.5 × 4.6 × 1 mm3. The electrodynamic 3D model simulations of the filter characteristics agree well with the results of measurements.
ERIC Educational Resources Information Center
Mid-Hudson Migrant Education Center, New Paltz, NY.
Written in Spanish, this guide for the grade 2 career education unit for migrant children focuses on the fields of recreation and transportation. Like the English version, the guide covers 11 jobs--travel agent, tour guide, camp counselor, coach, usher, school bus driver, airplane pilot, trucker, mover, railroad conductor, and astronaut. Student…
Kharissova, Oxana V; Osorio, Mario; Vázquez, Mario Sánchez; Kharisov, Boris I
2012-08-01
Using molecular mechanics (MM+), semi-empirical (PM6) and density functional theory (DFT) (B3LYP) methods we characterized bismuth nanotubes. In addition, we predicted the bismuth clusters {Bi(20)(C(5V)), Bi(24)(C(6v)), Bi(28)(C(1)), B(32)(D(3H)), Bi(60)(C(I))} and calculated their conductor properties.
NASA Technical Reports Server (NTRS)
Roth, W. L.; Muller, O.
1974-01-01
Crystal chemical principles and transport theory have been used to predict structures and specific compounds which might find application as solid electrolytes in rechargeable high energy and high power density batteries operating at temperatures less than 200 C. Structures with 1-, 2-, and 3-dimensional channels were synthesized and screened by nuclear magnetic resonance, dielectric loss, and conductivity. There is significant conductivity at room temperature in some of the materials but none attain a level that is comparable to beta-alumina. Microwave and fast pulse methods were developed to measure conductivity in powders and in small crystals.
NASA Astrophysics Data System (ADS)
Yi, You; Cheng, He; Xinxin, Wang
2018-01-01
The wind tunnel tests were carried out to obtain the variation laws of static aerodynamic characteristics of crescent and D-shape iced conductor with different wind velocities, wind attack angles and torsional elastic support stiffness. Test results show that the variation of wind velocity has a relatively large influence on the aerodynamic coefficients of crescent conductor with torsional elastic support 1. However, the influence on that of D-shape conductor is not obvious. With the increase of the torsional elastic support stiffness, the lift and moment coefficient curves of the crescent iced conductor form an obvious peak phenomenon in the range of 0 ° ∼30°. Meanwhile, the wind attack angle position corresponding to the maximum value of the lift and moment coefficients of the D-shape iced conductor appear a backward moving phenomenon.
Resistive foil edge grading for accelerator and other high voltage structures
Caporaso, George J.; Sampayan, Stephen F.; Sanders, David M.
2014-06-10
In a structure or device having a pair of electrical conductors separated by an insulator across which a voltage is placed, resistive layers are formed around the conductors to force the electric potential within the insulator to distribute more uniformly so as to decrease or eliminate electric field enhancement at the conductor edges. This is done by utilizing the properties of resistive layers to allow the voltage on the electrode to diffuse outwards, reducing the field stress at the conductor edge. Preferably, the resistive layer has a tapered resistivity, with a lower resistivity adjacent to the conductor and a higher resistivity away from the conductor. Generally, a resistive path across the insulator is provided, preferably by providing a resistive region in the bulk of the insulator, with the resistive layer extending over the resistive region.
NASA Astrophysics Data System (ADS)
Zeitlin, Bruce A.; Gregory, Eric; Pyon, Taeyoung; Scanlan, R. M.; Polyanskii, Anatolii A.; Lee, Peter J.
2004-06-01
A number of configurations of a mono element internal tin conductor (MEIT) were fabricated to explore the effect of internal fins on the effective filament size (Deff) and its effect on wire processing. A current density of 2.85 × 109 A/m2 (12 T) was achieved in a high tin, high Nb conductor. Wire lengths as long as 15.8 km at 0.254 mm diameter with breaks averaging 3 per unit length were achieved. Magnetization measurements and Magneto-Optical (MO) images were taken of the finned and non-fin conductor which indicated the fins appeared to be effective. The Deff achieved in the fin conductor was 80 μm compared with an equivalent conductor without a fin of 165 μm.
Magnetic circuit for hall effect plasma accelerator
NASA Technical Reports Server (NTRS)
Manzella, David H. (Inventor); Jacobson, David T. (Inventor); Hofer, Richard (Inventor); Peterson, Peter (Inventor); Jankovsky, Robert S. (Inventor)
2009-01-01
A Hall effect plasma accelerator includes inner and outer electromagnets, circumferentially surrounding the inner electromagnet along a thruster centerline axis and separated therefrom, inner and outer magnetic conductors, in physical connection with their respective inner and outer electromagnets, with the inner magnetic conductor having a mostly circular shape and the outer magnetic conductor having a mostly annular shape, a discharge chamber, located between the inner and outer magnetic conductors, a magnetically conducting back plate, in magnetic contact with the inner and outer magnetic conductors, and a combined anode electrode/gaseous propellant distributor, located at a bottom portion of the discharge chamber. The inner and outer electromagnets, the inner and outer magnetic conductors and the magnetically conducting back plate form a magnetic circuit that produces a magnetic field that is largely axial and radially symmetric with respect to the thruster centerline.
Electronic transport properties of 4f shell elements of liquid metal using hard sphere Yukawa system
NASA Astrophysics Data System (ADS)
Patel, H. P.; Sonvane, Y. A.; Thakor, P. B.
2018-04-01
The electronic transport properties are analyzed for 4f shell elements of liquid metals. To examine the electronic transport properties like electrical resistivity (ρ), thermal conductivity (σ) and thermo electrical power (Q), we used our own parameter free model potential with the Hard Sphere Yukawa (HSY) reference system. The screening effect on aforesaid properties has been examined by using different screening functions like Hartree (H), Taylor (T) and Sarkar (S). The correlations of our resultsand other data with available experimental values are intensely promising. Also, we conclude that our newly constructed parameter free model potential is capable of explaining the above mentioned electronic transport properties.
Data transmission element for downhole drilling components
Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Dahlgren, Scott; Fox, Joe; Sneddon, Cameron; Briscoe, Michael
2006-01-31
A robust data transmission element for transmitting information between downhole components, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The data transmission element components include a generally U-shaped annular housing, a generally U-shaped magnetically conductive, electrically insulating element such as ferrite, and an insulated conductor. Features on the magnetically conducting, electrically insulating element and the annular housing create a pocket when assembled. The data transmission element is filled with a polymer to retain the components within the annular housing by filling the pocket with the polymer. The polymer can bond with the annular housing and the insulated conductor but preferably not the magnetically conductive, electrically insulating element. A data transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe.
Conductors and semiconductors for advanced organic electronics
NASA Astrophysics Data System (ADS)
Meyer-Friedrichsen, Timo; Elschner, Andreas; Keohan, Frank; Lövenich, Wilfried; Ponomarenko, Sergei A.
2009-08-01
The development of suitable materials for organic electronics is still one of the key points to access new application areas with this promising technology. Semiconductors based on thiophene chemistry show very high charge carrier mobilities. The functionalization with linker groups provided materials that built monomolecular layers of the semiconductors on the hydrolyzed oxide surface of a silicon-wafer. This approach lead to self-assembled mono-layer field-effect transistors (SAM-FETs) with mobilities of up to 0.04 cm2/Vs, which is comparable to the values of the respective bulk thin film. Transparent inorganic conductors like ITO are highly conductive but the costly processing and the brittleness hamper their use in cost-sensitive and/or flexible devices. Highly conductive PEDOT-grades have been developed with conductivities of up to 1000 S/cm which are easily applicable by printing techniques and can be used as ITO replacement in devices such as touch panels or organic photovoltaics.
Status of high temperature superconductor development for accelerator magnets
NASA Technical Reports Server (NTRS)
Hirabayashi, H.
1995-01-01
High temperature superconductors are still under development for various applications. As far as conductors for magnets are concerned, the development has just been started. Small coils wound by silver sheathed Bi-2212 and Bi-2223 oxide conductors have been reported by a few authors. Essential properties of high T(sub c) superconductors like pinning force, coherent length, intergrain coupling, weak link, thermal property, AC loss and mechanical strength are still not sufficiently understandable. In this talk, a review is given with comparison between the present achievement and the final requirement for high T(sub c) superconductors, which could be particularly used in accelerator magnets. Discussions on how to develop high T(sub c) superconductors for accelerator magnets are included with key parameters of essential properties. A proposal of how to make a prototype accelerator magnet with high T(sub c) superconductors with prospect for future development is also given.
How do Orthopaedic Surgeons Address Psychological Aspects of Illness?
Vranceanu, Ana Maria; Beks, Reinier B.; Guitton, Thierry G.; Janssen, Stein J.; Ring, David
2017-01-01
Background: Orthopaedic surgeons have a pivotal role in transitioning the care of orthopedic patients from a biomedical to a biopsychosocial model. In an effort to foster this transition, we designed a study aimed to determine surgeons’ attitudes and practice of noticing, screening, discussing psychological illness with patients, as well as making referrals to address psychosocial issues in patients in need. Additionally, we asked surgeons to rank order potential barriers to and reasons for referrals to psychosocial treatment. Methods: Orthopaedic surgeons members of the Science and Variation Group and Ankle Platform (N =350) completed demographics, and a 4-part survey assessing the degree to which surgeons notice, assess, screen and refer for psychological treatments, as well ranked ordered barriers to engaging in these processes. Results: As a group surgeons were neutral to referral for psychological treatment and formal screening of psychological factors, and somewhat likely to notice and discuss psychological factors. Surgeons were more likely to refer for psychological treatment if they engaged in research, or if they reside in South America as opposed to North America. The highest ranked barriers to screening, noticing, discussing and referring for psychological treatment were lack of time, stigma and feeling uncomfortable. Conclusion: Overall surgeons are likely to notice and discuss psychological factors, but less likely to formally screen or refer for psychological treatment. Transition to biopsychosocial models should focus on problem solving these barriers by teaching surgeons communication skills to increase comfort with discussing psychoemotional factors associated with orthopedic problems. The use of empathic communication can be very helpful in normalizing the difficulty of coping with an orthopedic condition, and may facilitate referral. PMID:28271080
Development of a Novel Hybrid Multi-Junction Architecture for Silicon Solar Cells
2015-03-26
W Watts KOH Potassium Hydroxide xj Junction depth k Thermal conductivity z Normal distance l Conductor length σ Stefan...outermost orbit [9]. A material conducts electricity when its valence electrons move into the conduction band and become conductor electrons. Conductor ...become a conductor , it must absorb enough energy to overcome the band gap, which is the energy difference between the valence band and the conduction
NASA Astrophysics Data System (ADS)
Mulder, T.; van der Laan, D.; Weiss, J. D.; Dudarev, A.; Dhallé, M.; ten Kate, H. H. J.
2017-12-01
Two new ReBCO-CORC® based cable-in-conduit conductors (CICC) are developed by CERN in collaboration with ACT-Boulder. Both conductors feature a critical current of about 80 kA at 4.5 K and 12 T. One conductor is designed for operation in large detector magnets, while the other is aimed for application in fusion type magnets. The conductors use a six-around-one cable geometry with six flexible ReBCO CORC® strands twisted around a central tube. The fusion CICC is designed to be cooled by the internal forced flow of either helium gas or supercritical helium to cope with high heat loads in superconducting magnets in large fusion experimental reactors. In addition, the cable is enclosed by a stainless steel jacket to accommodate with the high level of Lorentz forces present in such magnets. Detector type magnets require stable, high-current conductors. Therefore, the detector CORC® CICC comprises an OFHC copper jacket with external conduction cooling, which is advantageous due to its simplicity. A 2.8 m long sample of each conductor is manufactured and prepared for testing in the Sultan facility at PSI Villigen. In the paper, the conductor design and assembly steps for both CORC® CICCs are highlighted.
Materials and methods for autonomous restoration of electrical conductivity
Blaiszik, Benjamin J; Odom, Susan A; Caruso, Mary M; Jackson, Aaron C; Baginska, Marta B; Ritchey, Joshua A; Finke, Aaron D; White, Scott R; Moore, Jeffrey S; Sottos, Nancy R; Braun, Paul V; Amine, Khalil
2014-03-25
An autonomic conductivity restoration system includes a solid conductor and a plurality of particles. The particles include a conductive fluid, a plurality of conductive microparticles, and/or a conductive material forming agent. The solid conductor has a first end, a second end, and a first conductivity between the first and second ends. When a crack forms between the first and second ends of the conductor, the contents of at least a portion of the particles are released into the crack. The cracked conductor and the released contents of the particles form a restored conductor having a second conductivity, which may be at least 90% of the first conductivity.
Giordano, S.
1963-11-12
A high peak power level r-f attenuator that is readily and easily insertable along a coaxial cable having an inner conductor and an outer annular conductor without breaking the ends thereof is presented. Spaced first and second flares in the outer conductor face each other with a slidable cylindrical outer conductor portion therebetween. Dielectric means, such as water, contact the cable between the flares to attenuate the radio-frequency energy received thereby. The cylindrical outer conductor portion is slidable to adjust the voltage standing wave ratio to a low level, and one of the flares is slidable to adjust the attenuation level. An integral dielectric container is also provided. (AFC)