External pressure measurement system
NASA Astrophysics Data System (ADS)
Chandler, Jon K.; Fowler, Don P.
Hydraulic systems comprise an important part of jet aircraft and their pressure needs must be checked constantly. Tests of the prototype external pressure measurement system show that it is possible to accurately convert the small expansion of tubing with pressure into a direct pressure reading without inserting a pressure gage into the piping system. The tool described in the paper is a clamp-on displacement transducer that can read pressure directly in PSI from 0 to 5000. Some limitations concerning temperature and accuracy should be remedied by additional design work. The system promises to streamline troubleshooting of all types of piping systems.
Hu, Mei-Hua; Chan, Wei-Hung; Chen, Yao-Chang; Cherng, Chen-Hwan; Lin, Chih-Kung; Tsai, Chien-Sung; Chou, Yu-Ching; Huang, Go-Shine
2016-01-01
The effects of intravenous (IV) catheter gauge and pressurization of IV fluid (IVF) bags on fluid flow rate have been studied. However, the pressure needed to achieve a flow rate equivalent to that of a 16 gauge (G) catheter through smaller G catheters and the potential for endothelial damage from the increased kinetic energy produced by higher pressurization are unclear. Constant pressure on an IVF bag was maintained by an automatic adjustable pneumatic pressure regulator of our own design. Fluids running through 16 G, 18 G, 20 G, and 22 G catheters were assessed while using IV bag pressurization to achieve the flow rate equivalent to that of a 16 G catheter. We assessed flow rates, kinetic energy, and flow injury to rabbit inferior vena cava endothelium. By applying sufficient external constant pressure to an IVF bag, all fluids could be run through smaller (G) catheters at the flow rate in a 16 G catheter. However, the kinetic energy increased significantly as the catheter G increased. Damage to the venous endothelium was negligible or minimal/patchy cell loss. We designed a new rapid infusion system, which provides a constant pressure that compresses the fluid volume until it is free from visible residual fluid. When large-bore venous access cannot be obtained, multiple smaller catheters, external pressure, or both should be considered. However, caution should be exercised when fluid pressurized to reach a flow rate equivalent to that in a 16 G catheter is run through a smaller G catheter because of the profound increase in kinetic energy that can lead to venous endothelium injury.
NASA Technical Reports Server (NTRS)
Pendergrass, J. R.; Walsh, R. L.
1975-01-01
An examination of the factors which modify the simulation of a constraint in the motion of the aft attach points of the orbiter and external tank during separation has been made. The factors considered were both internal (spring and damper constants) and external (friction coefficient and dynamic pressure). The results show that an acceptable choice of spring/damper constant combinations exist over the expected range of the external factors and that the choice is consistent with a practical integration interval. The constraint model is shown to produce about a 10 percent increase in the relative body pitch angles over the unconstrained case whereas the MDC-STL constraint model is shown to produce about a 38 percent increase.
Acrylic Plastic Spherical Pressure Hull for Continental Shelf Depths
1993-03-01
the con- l and secure conduit for the instrumentation leads at cave surface of the sphere (figure 26). The meridi- any external pressure to which the...constant pressure monitoring. In-line pressure CEA-06-1 25WT-120 with a gage factor of 2.11, transducers sense chamber pressures and send a bonded to the...wired to a strain gage conditioner that sensed strain as an analog FINDINGS voltage corresponding to the change in resistance occuring in each gage as it
Ab-initio study of (Ga,Cr)N and (Ga,Mn)N DMSs: under hydrostatic pressure
NASA Astrophysics Data System (ADS)
Rani, Anita; Kumar, Ranjan
2018-03-01
The influence of hydrostatic pressure between 0-100 GPa on structural, electronic and magnetic properties of CrxGa1-xN and MnxGa1-xN (x = 0.25) diluted magnetic semiconductors has been studied. The calculations have been performed using DFT as implemented in code SIESTA. LDA + U as exchange-correlation (XC) potential have been used to study the parameters. Under external pressure, shifting in both valence band and conduction band energy levels from their actual positions has been observed, which lead to modification of electronic properties. Also, N0 α, s-d exchange constant and p-d exchange constants, N0 β have been calculated at different pressures. Both the compounds show half metallic nature at studied pressure range.
On Thermodiffusion and Gauge Transformations for Thermodynamic Fluxes and Driving Forces
NASA Astrophysics Data System (ADS)
Goldobin, D. S.
2017-12-01
We discuss the molecular diffusion transport in infinitely dilute liquid solutions under nonisothermal conditions. This discussion is motivated by an occurring misinterpretation of thermodynamic transport equations written in terms of chemical potential in the presence of temperature gradient. The transport equations contain the contributions owned by a gauge transformation related to the fact that chemical potential is determined up to the summand of form ( AT + B) with arbitrary constants A and B, where constant A is owned by the entropy invariance with respect to shifts by a constant value and B is owned by the potential energy invariance with respect to shifts by a constant value. The coefficients of the cross-effect terms in thermodynamic fluxes are contributed by this gauge transformation and, generally, are not the actual cross-effect physical transport coefficients. Our treatment is based on consideration of the entropy balance and suggests a promising hint for attempts of evaluation of the thermal diffusion constant from the first principles. We also discuss the impossibility of the "barodiffusion" for dilute solutions, understood in a sense of diffusion flux driven by the pressure gradient itself. When one speaks of "barodiffusion" terms in literature, these terms typically represent the drift in external potential force field (e.g., electric or gravitational fields), where in the final equations the specific force on molecules is substituted with an expression with the hydrostatic pressure gradient this external force field produces. Obviously, the interpretation of the latter as barodiffusion is fragile and may hinder the accounting for the diffusion fluxes produced by the pressure gradient itself.
NASA Technical Reports Server (NTRS)
Allen, John L
1956-01-01
Unsteady shock-induced separation of the ramp boundary layer was reduced and stabilized more effectively by external perforations than by external or internal slots. At Mach 2.0 peak total-pressure recovery was increased from 0.802 to 0.89 and stable mass-flow range was increased 185 percent over that for the solid ramp. Peak pressure recovery occurred just before instability. The 7 and one-third-diameter duct ahead of the engine reduced large total-pressure distortions but was not as successful for small distortions as obtained with throat bleed. By removing boundary-layer air the bypass nearly recovered the total-pressure loss due to the long duct.
System Regulates the Water Contents of Fuel-Cell Streams
NASA Technical Reports Server (NTRS)
Vasquez, Arturo; Lazaroff, Scott
2005-01-01
An assembly of devices provides for both humidification of the reactant gas streams of a fuel cell and removal of the product water (the water generated by operation of the fuel cell). The assembly includes externally-sensing forward-pressure regulators that supply reactant gases (fuel and oxygen) at variable pressures to ejector reactant pumps. The ejector supply pressures depend on the consumption flows. The ejectors develop differential pressures approximately proportional to the consumption flow rates at constant system pressure and with constant flow restriction between the mixer-outlet and suction ports of the ejectors. For removal of product water from the circulating oxygen stream, the assembly includes a water/gas separator that contains hydrophobic and hydrophilic membranes. The water separator imposes an approximately constant flow restriction, regardless of the quality of the two-phase flow that enters it from the fuel cell. The gas leaving the water separator is nearly 100 percent humid. This gas is returned to the inlet of the fuel cell along with a quantity of dry incoming oxygen, via the oxygen ejector, thereby providing some humidification.
NASA Astrophysics Data System (ADS)
Islam, A. K. M. Farid Ul; Liton, M. N. H.; Anowar, M. G. M.
2018-06-01
The pressure dependent mechanical stability, electronic structure and optical properties of Ba(Mg1/3Nb2/3)O3 (BMN) perovskite have been investigated in the framework of the density functional theory. Geometry optimization shows that the BMN possesses more compressibility along c-axis. The dependency of the elastic constants, the aggregated elastic moduli (B, G) and the elastic anisotropy on pressure has also been studied. BMN shows brittle character at ambient pressure but it becomes ductile, and also stiffer and anisotropic nature due to external pressure. Electronic structure indicates the conversion of indirect to direct band gap with increasing pressure. Dominated ionic character of BMN is confirmed from the bond population analysis. By analyzing the optical spectra, a red shift at the band edge is observed in the visible range indicating the band gap tuning. It is seen that the static dielectric constant increases with pressure.
NASA Technical Reports Server (NTRS)
Wilson, Jack; Paxson, Daniel E.
2002-01-01
In one-dimensional calculations of pulsed detonation engine (PDE) performance, the exit boundary condition is frequently taken to be a constant static pressure. In reality, for an isolated detonation tube, after the detonation wave arrives at the exit plane, there will be a region of high pressure, which will gradually return to ambient pressure as an almost spherical shock wave expands away from the exit, and weakens. Initially, the flow is supersonic, unaffected by external pressure, but later becomes subsonic. Previous authors have accounted for this situation either by assuming the subsonic pressure decay to be a relaxation phenomenon, or by running a two-dimensional calculation first, including a domain external to the detonation tube, and using the resulting exit pressure temporal distribution as the boundary condition for one-dimensional calculations. These calculations show that the increased pressure does affect the PDE performance. In the present work, a simple model of the exit process is used to estimate the pressure decay time. The planar shock wave emerging from the tube is assumed to transform into a spherical shock wave. The initial strength of the spherical shock wave is determined from comparison with experimental results. Its subsequent propagation, and resulting pressure at the tube exit, is given by a numerical blast wave calculation. The model agrees reasonably well with other, limited, results. Finally, the model was used as the exit boundary condition for a one-dimensional calculation of PDE performance to obtain the thrust wall pressure for a hydrogen-air detonation in tubes of length to diameter ratio (L/D) of 4, and 10, as well as for the original, constant pressure boundary condition. The modified boundary condition had no performance impact for values of L/D > 10, and moderate impact for L/D = 4.
On the use of external burning to reduce aerospace vehicle transonic drag
NASA Technical Reports Server (NTRS)
Trefny, Charles J.
1990-01-01
The external combustion of hydrogen to reduce the transonic drag of aerospace vehicles is currently being investigated. A preliminary analysis based on a constant pressure control volume is discussed. Results indicate that the specific impulse of the external burning process rivals that of a turbojet and depends on the severity of the initial base drag as well as on the Mach flight number and the equivalence ratio. A test program was conducted to investigate hydrogen-air flame stability at the conditions of interest and to demonstrate drag reduction on a simple expansion ramp. Initial test results are presented and compared with the control-volume analysis. The expansion ramp surface pressure coefficient showed little variation with fuel pressure and altitude, in disagreement with the analysis. Flame stability results were encouraging and indicate that stable combustion is possible over an adequate range of conditions. Facility interference and chemical kinetics phenomena that make interpretation of subscale ground test data difficult are discussed.
External Cooling Coupled to Reduced Extremity Pressure Device
NASA Technical Reports Server (NTRS)
Kuznetz, Lawrence H.
2011-01-01
Although suited astronauts are currently cooled with a Liquid Cooled Ventilation Garment (LCVG), which can remove up to 85 percent of body heat, their effectiveness is limited because cooling must penetrate layers of skin, muscle, fat, bone, and tissue to reach the bloodstream, where its effect is prominent. Vasoconstriction further reduces the effectiveness by limiting arterial flow when exposed to cold (the frostbite response), resulting in a time constant on the order of 20 minutes from application to maximum effect. This delay can be crucial in severe exposure to hypo- or hyper-thermic conditions, compromising homeostasis. The purpose of this innovation is to provide a lightweight, effective means of delivering heat or cold from an external source directly to the bloodstream. The effectiveness of this ECCREP (External Cooling Coupled to Reduced Extremity Pressure) device is based on not having to penetrate layers of skin, muscle, fat, and tissue, thereby avoiding the thermal lag associated with their mass and heat capacity. This is accomplished by means of an outer boot operating at a slightly reduced pressure than the rest of the body, combined with an inner boot cooled or heated by an external source via water or chemicals. Heat transfer from the external source to the foot takes place by means of circulating water or flexible heat pipes.
Characterization of Engine Control Authority on HCCI Combustion as the High Load Limit is Approached
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szybist, James P; Edwards, Kevin Dean; Foster, Matthew
2013-01-01
While the potential emissions and efficiency benefits of homogeneous charge compression ignition (HCCI) combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on characterizing the authority of the available engine controls as the high load limit of HCCI combustion is approached. The experimental work is performed on a boosted single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), and a hydraulic valve actuation (HVA) valve train to enable the negative valve overlap (NVO) breathing strategy. Valve lift and duration are held constant whilemore » phasing is varied in an effort to make the results as relevant as possible to production intent cam-based variable valve actuation (VVA) systems on multi-cylinder engines. Results presented include engine loads from 350 to 650 kPa IMEPnet and manifold pressure from 98 to 190 kPaa at 2000 rpm. It is found that in order to increase engine load to 650 kPa IMEPnet, it is necessary to increase manifold pressure and external EGR while reducing the NVO duration. Both NVO duration and fuel injection timing are effective means of controlling combustion phasing, with NVO duration being a coarse control and fuel injection timing being a fine control. NOX emissions are low throughout the study, with emissions below 0.1 g/kW-h at all boosted HCCI conditions, while good combustion efficiency is maintained (>96.5%). Net indicated thermal efficiency increases with load up to 600 kPa IMEPnet, where a peak efficiency of 41% is achieved. Results of independent parametric investigations are presented on the effect of external EGR, intake effect of manifold pressure, and the effect of NVO duration. It is found that increasing EGR at a constant manifold pressure and increasing manifold pressure at a constant EGR rate both have the effect of retarding combustion phasing. It is also found that combustion phasing becomes increasingly sensitive to NVO duration as engine load increases. Finally, comparisons are made between three commonly used noise metrics (AVL noise meter, ringing intensity (RI), and maximum pressure rise rate (MPRR)). It is found that compared to the AVL noise meter, RI significantly underestimates combustion noise under boosted conditions.« less
Li, Xiaogai; von Holst, Hans; Kleiven, Svein
2013-01-01
A 3D finite element (FE) model has been developed to study the mean intracranial pressure (ICP) response during constant-rate infusion using linear poroelasticity. Due to the uncertainties in the poroelastic constants for brain tissue, the influence of each of the main parameters on the transient ICP infusion curve was studied. As a prerequisite for transient analysis, steady-state simulations were performed first. The simulated steady-state pressure distribution in the brain tissue for a normal cerebrospinal fluid (CSF) circulation system showed good correlation with experiments from the literature. Furthermore, steady-state ICP closely followed the infusion experiments at different infusion rates. The verified steady-state models then served as a baseline for the subsequent transient models. For transient analysis, the simulated ICP shows a similar tendency to that found in the experiments, however, different values of the poroelastic constants have a significant effect on the infusion curve. The influence of the main poroelastic parameters including the Biot coefficient α, Skempton coefficient B, drained Young's modulus E, Poisson's ratio ν, permeability κ, CSF absorption conductance C(b) and external venous pressure p(b) was studied to investigate the influence on the pressure response. It was found that the value of the specific storage term S(ε) is the dominant factor that influences the infusion curve, and the drained Young's modulus E was identified as the dominant parameter second to S(ε). Based on the simulated infusion curves from the FE model, artificial neural network (ANN) was used to find an optimised parameter set that best fit the experimental curve. The infusion curves from both the FE simulation and using ANN confirmed the limitation of linear poroelasticity in modelling the transient constant-rate infusion.
NASA Technical Reports Server (NTRS)
1976-01-01
The entropy of a gas system with the number of particles subject to external control is maximized to derive relations between the thermodynamic variables that obtain at equilibrium. These relations are described in terms of the chemical potential, defined as equivalent partial derivatives of entropy, energy, enthalpy, free energy, or free enthalpy. At equilibrium, the change in total chemical potential must vanish. This fact is used to derive the equilibrium constants for chemical reactions in terms of the partition functions of the species involved in the reaction. Thus the equilibrium constants can be determined accurately, just as other thermodynamic properties, from a knowledge of the energy levels and degeneracies for the gas species involved. These equilibrium constants permit one to calculate the equilibrium concentrations or partial pressures of chemically reacting species that occur in gas mixtures at any given condition of pressure and temperature or volume and temperature.
Siebert, Tobias; Rode, Christian; Till, Olaf; Stutzig, Norman; Blickhan, Reinhard
2016-05-03
Transversal unidirectional compression applied to muscles via external loading affects muscle contraction dynamics in the longitudinal direction. A recent study reported decreasing longitudinal muscle forces with increasing transversal load applied with a constant contact area (i.e., leading to a simultaneous increase in local pressure). To shed light on these results, we examine whether the decrease in longitudinal force depends on the load, the local pressure, or both. To this end, we perform isometric experiments on rat M. gastrocnemius medialis without and with transversal loading (i) changing the local pressure from 1.1-3.2Ncm(-2) (n=9) at a constant transversal load (1.62N) and (ii) increasing the transversal load (1.15-3.45N) at a constant local pressure of 2.3Ncm(-2) (n=7). While we did not note changes in the decrease in longitudinal muscle force in the first experiment, the second experiment resulted in an almost-linear reduction of longitudinal force between 7.5±0.6% and 14.1±1.7%. We conclude that the observed longitudinal force reduction is not induced by local effects such as malfunction of single muscle compartments, but that similar internal stress conditions and myofilament configurations occur when the local pressure changes given a constant load. The decreased longitudinal force may be explained by increased internal pressure and a deformed myofilament lattice that is likely associated with the decomposition of cross-bridge forces on the one hand and the inhibition of cross-bridges on the other hand. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vortex Formation During Unsteady Boundary-Layer Separation
NASA Astrophysics Data System (ADS)
Das, Debopam; Arakeri, Jaywant H.
1998-11-01
Unsteady laminar boundary-layer separation is invariably accompanied by the formation of vortices. The aim of the present work is to study the vortex formation mechanism(s). An adverse pressure gradient causing a separation can be decomposed into a spatial component ( spatial variation of the velocity external to the boundary layer ) and a temporal component ( temporal variation of the external velocity ). Experiments were conducted in a piston driven 2-D water channel, where the spatial component could be be contolled by geometry and the temporal component by the piston motion. We present results for three divergent channel geometries. The piston motion consists of three phases: constant acceleration from start, contant velocity, and constant deceleration to stop. Depending on the geometry and piston motion we observe different types of unsteady separation and vortex formation.
Parameter identification of a rotor supported in a pressurized bearing lubricated with water
NASA Technical Reports Server (NTRS)
Grant, John W.; Muszynska, Agnes; Bently, Donald E.
1994-01-01
A rig for testing an externally pressurized (hydrostatic), water-lubricated bearing was developed. Applying a nonsynchronous sweep frequency, rotating perturbation force with a constant amplitude as an input, rotor vibration response data was acquired in Bode and Dynamic Stiffness formats. Using this data, the parameters of the rotor/bearing system were identified. The rotor/bearing model was represented by the generalized (modal) parameters of the first lateral mode, with the rotational character of the fluid force taken into account.
An apparatus for altering the mechanical load of the respiratory system.
Younes, M; Bilan, D; Jung, D; Kroker, H
1987-06-01
We describe an apparatus for altering the mechanical load against which the respiratory muscles operate in humans. A closed system incorporates a rolling seal spirometer. The spirometer piston shaft is coupled to a fast-responding linear actuator that develops force in proportion to desired command signals. The command signal may be flow (resistive loading or unloading), volume (elastic loading or unloading), constant voltage (continuous positive or negative pressure), or any external function. Combinations of loads can be applied. Logic circuits permit application of the load at specific times during the respiratory cycle, and the magnitude of the loads is continuously adjustable. Maximum pressure output is +/- 20 cmH2O. The apparatus permits loading or unloading over a range of ventilation extending from resting levels to those observed during high levels of exercise (over 100 l/min). In response to a square-wave input, pressure rises exponentially with a time constant of 20 ms.
NASA Astrophysics Data System (ADS)
Ali, Md. Lokman; Rahaman, Md. Zahidur
2018-04-01
By using first principles calculation dependent on the density functional theory (DFT), we have investigated the mechanical, structural properties and the Debye temperature of Fe2ScM (M=P and As) compounds under various pressures up to 60 GPa. The optical properties have been investigated under zero pressure. Our calculated optimized structural parameters of both the materials are in good agreement with other theoretical predictions. The calculated elastic constants show that Fe2ScM (M=P and As) compounds are mechanically stable under external pressure below 60 GPa. From the elastic constants, the shear modulus G, the bulk modulus B, Young’s modulus E, anisotropy factor A and Poisson’s ratio ν are calculated by using the Voigt-Reuss-Hill approximation. The Debye temperature and average sound velocities are also investigated from the obtained elastic constants. The detailed analysis of all optical functions reveals that both compounds are good dielectric material.
He, Zhipeng; Liu, Zhao; Zhou, Xiaofeng; Huang, He
2018-06-01
The secondary structure transitions of regenerated silk fibroin (RSF) under different external perturbations have been studied extensively, except for pressure. In this work, time-resolved infrared spectroscopy with the attenuated total reflectance (ATR) accessory was employed to follow the secondary structure transitions of RSF in its wet film under low pressure. It has been found that pressure alone is favorable only to the formation of β-sheet structure. Under constant pressure there is an optimum amount of D 2 O in the wet film (D 2 O : film = 2:1) so as to provide the optimal condition for the reorganization of the secondary structure and to have the largest formation of β-sheet structure. Under constant amount of D 2 O and constant pressure, the secondary structure transitions of RSF in its wet film can be divided into three stages along with time. In the first stage, random coil, α-helix, and β-turn were quickly transformed into β-sheet. In the second stage, random coil and β-turn were relatively slowly transformed into β-sheet and α-helix, and the content of α-helix was recovered to the value prior to the application of pressure. In the third and final stage, no measurable changes can be found for each secondary structure. This study may be helpful to understand the secondary structure changes of silk fibroin in silkworm's glands under hydrostatic pressure. © 2018 Wiley Periodicals, Inc.
Preventing Molecular and Particulate Infiltration in a Confined Volume
NASA Technical Reports Server (NTRS)
Scialdone, John J.
1999-01-01
Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, C., E-mail: lichun@nwpu.edu.cn; Shang, J.; Yue, Z.
2015-07-15
In this paper, the basic electronic structures and elastic properties of Ni{sub 3}Al doping with alloying elements (Re, Cr, and Mo) under different pressures have been investigated using first-principles calculations based on density functional theory. It is shown that both alloying elements and external applied pressure contribute positively to the elastic properties of Ni{sub 3}Al, and the configurations of the compounds remain almost unchanged. The calculated elastic constants and moduli increase linearly with the pressure increasing from 0 and 40 GPa. Among the alloying elements studied in the present work, Re exhibits the most significant effect compared with the othermore » elements, showing its practical importance. Especially, if both alloying elements doping and pressure effects are considered simultaneously, which has not been considered previously, the studied compounds exhibit an even better elastic property than the simple superposition of the two influences. Such synergistic effect demonstrates promising applications of Ni-based single crystal superalloys in possible extreme mechanical environments.« less
Annular Internal-External-Expansion Rocket Nozzles for Large Booster Applications
NASA Technical Reports Server (NTRS)
Connors, James F.; Cubbison, Robert W.; Mitchell, Glenn A.
1961-01-01
For large-thrust booster applications, annular rocket nozzles employing both internal and external expansion are investigated. In these nozzles, free-stream air flows through the center as well as around the outside of the exiting jet. Flaps for deflecting the rocket exhaust are incorporated on the external-expansion surface for thrust-vector control. In order to define nozzle off-design performance, thrust vectoring effectiveness, and external stream effects, an experimental investigation was conducted on two annular nozzles with area ratios of 15 and 25 at Mach 0, 2, and 3 in the Lewis 10- by 10-foot wind tunnel. Air, pressurized to 600 pounds per square inch absolute, was used to simulate the exhaust flow. For a nozzle-pressure-ratio range of 40 to 1000, the ratio of actual to ideal thrust was essentially constant at 0.98 for both nozzles. Compared with conventional convergent-divergent configurations on hypothetical boost missions, the performance gains of the annular nozzle could yield significant orbital payload increases (possibly 8 to 17 percent). A single flap on the external-expansion surface of the area-ratio-25 annular nozzle produced a side force equal to 4 percent of the axial force with no measurable loss in axial thrust.
Structural and electronic properties of high pressure phases of lead chalcogenides
NASA Astrophysics Data System (ADS)
Petersen, John; Scolfaro, Luisa; Myers, Thomas
2012-10-01
Lead chalcogenides, most notably PbTe and PbSe, have become an active area of research due to their thermoelectric properties. The high figure of merit (ZT) of these materials has brought much attention to them, due to their ability to convert waste heat into electricity. Variation in synthesis conditions gives rise to a need for analysis of structural and thermoelectric properties of these materials at different pressures. In addition to the NaCl structure at ambient conditions, lead chalcogenides have a dynamic orthorhombic (Pnma) intermediate phase and a higher pressure yet stable CsCl phase. By altering the lattice constant, we simulate the application of external pressure; this has notable effects on ground state total energy, band gap, and structural phase. Using the General Gradient Approximation (GGA) in Density Functional Theory (DFT), we calculate the phase transition pressures by finding the differences in enthalpy from total energy calculations. For each phase, elastic constants, bulk modulus, shear modulus, Young's modulus, and hardness are calculated, using two different approaches. In addition to structural properties, we analyze the band structure and density of states at varying pressures, paying special note to thermoelectric implications.
NASA Astrophysics Data System (ADS)
Miyazono, Keitaro; Hanaya, Tadashi; Sueishi, Yoshimi
2014-07-01
By synthesizing unique nitroxide probes (α-substituted phenyl-2,4,6-trimethoxybenzyl(t-butyl)nitroxide), we have shown that p-sulfonatocalix[8]arene (Calix-S8) and γ-cyclodextin (γ-CD) form electron spin resonance spectroscopically separable group-inclusion complexes (α-substituted phenyl-in (R-in) and t-butyl-in complexes) and determined the group-inclusion constants of Calix-S8 and γ-CD. Using nitroxide probes, we have examined the effects of substituent and external pressure on group-inclusion complexation with Calix-S8 and γ-CD. Experiments on pressure dependence enabled us to calculate the reaction volume (Δ V) for R-in and t-butyl-in complex formations. Δ V for group-in complexation with Calix-S8 had negative values. In contrast, Δ V values for γ-CD showed positive values, which is responsible for the repelled water molecules in the CD cavity. The characteristic pressure effects on group-in complexation suggest that group recognition by γ-CD is sensitive when compared with that by Calix-S8.
Generation of a pulsed low-energy electron beam using the channel spark device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elgarhy, M. A. I., E-mail: elgarhy@azhar.edu.eg; Hassaballa, S. E.; Rashed, U. M.
2015-12-15
For the generation of low-energy electron beam, the design and characteristics of channel spark discharge (CSD) operating at a low voltage are presented in this paper. The discharge voltage, discharge current, X-ray emissions, and electron beam current were experimentally determined. The effects of the applied voltage, working gas pressure, and external capacitance on the CSD and beam parameters were measured. At an applied voltage of 11 kV, an oxygen gas pressure of 25 mTorr, and an external capacitance of 16.45 nF, the maximum measured current was 900 A. The discharge current increased with the increase in the pressure and capacitance,more » while its periodic time decreased with the increase in the pressure. Two types of the discharge were identified and recorded: the hollow cathode discharge and the conduction discharge. A Faraday cup was used to measure the beam current. The maximum measured beam current was 120 A, and the beam signal exhibited two peaks. The increase in both the external capacitance and the applied discharge voltage increased the maximum electron beam current. The electron-beam pulse time decreased with the increase in the gas pressure at a constant voltage and increased with the decrease in the applied discharge voltage. At an applied voltage of 11 kV and an oxygen gas pressure of 15 mTorr, the maximum beam energy was 2.8 keV. The X-ray signal intensity decreased with the increase in the gas pressure and increased with the increase in the capacitance.« less
Effects of osmotic pressure in the extracellular matrix on tissue deformation.
Lu, Y; Parker, K H; Wang, W
2006-06-15
In soft tissues, large molecules such as proteoglycans trapped in the extracellular matrix (ECM) generate high levels of osmotic pressure to counter-balance external pressures. The semi-permeable matrix and fixed negative charges on these molecules serve to promote the swelling of tissues when there is an imbalance of molecular concentrations. Structural molecules, such as collagen fibres, form a network of stretch-resistant matrix, which prevents tissue from over-swelling and keeps tissue integrity. However, collagen makes little contribution to load bearing; the osmotic pressure in the ECM is the main contributor balancing external pressures. Although there have been a number of studies on tissue deformation, there is no rigorous analysis focusing on the contribution of the osmotic pressure in the ECM on the viscoelastic behaviour of soft tissues. Furthermore, most previous works were carried out based on the assumption of infinitesimal deformation, whereas tissue deformation is finite under physiological conditions. In the current study, a simplified mathematical model is proposed. Analytic solutions for solute distribution in the ECM and the free-moving boundary were derived by solving integro-differential equations under constant and dynamic loading conditions. Osmotic pressure in the ECM is found to contribute significantly to the viscoelastic characteristics of soft tissues during their deformation.
NASA Technical Reports Server (NTRS)
Torrence, M. G.
1975-01-01
An investigation of a fixed-geometry, swept external-internal compression inlet was conducted at a Mach number of 6.0 and a test-section Reynolds number of 1.55 x 10 to the 7th power per meter. The test conditions was constant for all runs with stagnation pressure and temperature at 20 atmospheres and 500 K, respectively. Tests were made at angles of attack of -5 deg, 0 deg, 3 deg, and 5 deg. Measurements consisted of pitot- and static-pressure surveys in inlet throat, wall static pressures, and surface temperatures. Boundary-layer bleed was provided on the centerbody and on the cowl internal surface. The inlet performance was consistently high over the range of the angle of attack tested, with an overall average total pressure recovery of 78 percent and corresponding adiabatic kinetic-energy efficiency of 99 percent. The inlet throat flow distribution was uniform and the Mach number and pressure level were of the correct magnitude for efficient combustor design. The utilization of a swept compression field to meet the starting requirements of a fixed-geometry inlet produced neither flow instability nor a tendency to unstart.
Constant flow-driven microfluidic oscillator for different duty cycles
Kim, Sung-Jin; Yokokawa, Ryuji; Lesher-Perez, Sasha Cai; Takayama, Shuichi
2012-01-01
This paper presents microfluidic devices that autonomously convert two constant flow inputs into an alternating oscillatory flow output. We accomplish this hardware embedded self-control programming using normally closed membrane valves that have an inlet, an outlet, and a membrane-pressurization chamber connected to a third terminal. Adjustment of threshold opening pressures in these 3-terminal flow switching valves enabled adjustment of oscillation periods to between 57–360 s with duty cycles of 0.2–0.5. These values are in relatively good agreement with theoretical values, providing the way for rational design of an even wider range of different waveform oscillations. We also demonstrate the ability to use these oscillators to perform temporally patterned delivery of chemicals to living cells. The device only needs a syringe pump, thus removing the use of complex, expensive external actuators. These tunable waveform microfluidic oscillators are envisioned to facilitate cell-based studies that require temporal stimulation. PMID:22206453
Mechanics and applications of pressure adaptive honeycomb
NASA Astrophysics Data System (ADS)
Vos, Roelof
A novel adaptive aerostructure is presented that relies on certified aerospace materials and can therefore be applied in conventional passenger aircraft. This structure consists of a honeycomb material which' cells extend over a significant length perpendicular to the plane of the cells. Each of the cells contains an inelastic pouch (or bladder) that forms a circular tube when the cell forms a perfect hexagon. By changing the cell differential pressure (CDP) the stiffness of the honeycomb can be altered. Using an external force or the elastic force within the honeycomb material, the honeycomb can be deformed such that the cells deviate from their perfect-hexagonal shape. It can be shown that by increasing the CDP, the structure eventually returns to a perfect hexagon. By doing so, a fully embedded pneumatic actuator is created that can perform work and substitute conventional low-bandwidth flight control actuators. It is shown that two approaches can be taken to regulate the stiffness of this embedded actuator: (1) The first approach relies on the pouches having a fixed amount of air in them and stiffness is altered by a change in ambient pressure. Coupled to the ambient pressure-altitude cycle that aircraft encounter during each flight, this approach yields a true adaptive aerostructure that operates independently of pilot input and is controlled solely by the altitude the aircraft is flying at. (2) The second approach relies on a controlled constant CDP. This CDP could be supplied from one of the compressor stages of the engine as a form of bleed air. Because of the air-tight pouches there would essentially be no mass flow, meaning engine efficiency would not be significantly affected due to this application. By means of a valve system the pilot could have direct control over the pressure and, consequently, the stiffness of the structure. This allows for much higher CDPs (on the order of 1MPa) than could physically be achieved by relying on the ambient pressure decrease with altitude. This option does require more infrastructure like tubing, valves, and supporting electronics from the cockpit. Applications of pressure adaptive honeycomb are tailored primarily towards low-bandwidth applications like secondary flight control. The most profound application is the morphing of an entire wing section, from leading to trailing edge, due to the adaptive honeycomb. On a smaller scale, other examples include a solid state pressure adaptive flap, a pressure adaptive droop nose, a pressure adaptive Gurney flap and a pressure adaptive engine inlet. Each of these applications is based on the same principle of stiffness alteration with pressure and can be used with either actuation option (constant mass or constant pressure). A model that relates the volumetric change of the honeycomb cells to the external blocked stress was shown to correlate well to experiments that were carried out on several test articles. Based on this model it was estimated that pressure adaptive honeycomb has a maximum mass-specific energy density of 12.4J/g, for the case of an externally applied CDP of 0.9MPa (can be supplied from a high-pressure compressor stage of a gas turbine). In addition, it was shown that a maximum strain of 76% can be achieved and that the maximum blocked stress amounts to 0.82MPa. In the case of a 40kPa drop in atmospheric pressure and constant mass of air in the pouches, the maximum mass specific energy amounts to 1.1J/g and a maximum blocked force of 70kPa can be attained. Pressure adaptive honeycomb was embedded into a 25%c adaptive flap on a NACA2412 wing section with a chord of 1.08m. Wind tunnel tests at Reynolds number of 1 million demonstrated a shift in the cl -- alpha curve upwards by an average of 0.3, thereby increasing the maximum lift coefficient from 1.27 to 1.52. This successfully demonstrated the application of pressure adaptive honeycomb embedded in a morphing aircraft structure.
Unstable equilibrium behaviour in collapsible tubes.
Bertram, C D
1986-01-01
Thick-walled silicone rubber tube connected to rigid pipes upstream and downstream was externally pressurised (pe) to cause collapse while aqueous fluid flowed through propelled by a constant upstream head. Three types of equilibrium were found: stable equilibria (steady flow) at high downstream flow resistance R2, self-excited oscillations at low R2, and 'unattainable' (by varying external pressure) or exponentially unstable equilibria at intermediate R2. The self-excited oscillations were highly non-linear and appeared in four, apparently discrete, frequency bands: 2.7 Hz, 3.8-5.0 Hz, 12-16 Hz and 60-63 Hz, suggesting that the possible oscillation modes may be harmonically related. Stable, intermediate 'two-in-every-three-beats' oscillation was also observed, with a repetition frequency in the 3.8-5.0 Hz band. As pe was increased, self-excited oscillations were eventually suppressed, leaving internal fluid pressure varying with no single dominant frequency as a result of turbulent jet dissipation at the downstream rigid pipe connection. Comparison of pressure-wave velocity calculated from the local pressure-area relation for the tube with fluid velocity indicated that supercritical velocities were attained in the course of the self-excited oscillations.
Microgravity combustion of dust suspensions
NASA Technical Reports Server (NTRS)
Lee, John H. S.; Peraldi, Olivier; Knystautas, Rom
1993-01-01
Unlike the combustion of homogeneous gas mixtures, there are practically no reliable fundamental data (i.e., laminar burning velocity, flammability limits, quenching distance, minimum ignition energy) for the combustion of heterogeneous dust suspensions. Even the equilibrium thermodynamic data such as the constant pressure volume combustion pressure and the constant pressure adiabatic flame temperature are not accurately known for dust mixtures. This is mainly due to the problem of gravity sedimentation. In normal gravity, turbulence, convective flow, electric and acoustic fields are required to maintain a dust in suspension. These external influences have a dominating effect on the combustion processes. Microgravity offers a unique environment where a quiescent dust cloud can in principle be maintained for a sufficiently long duration for almost all combustion experiments (dust suspensions are inherently unstable due to Brownian motion and particle aggregation). Thus, the microgravity duration provided by drop towers, parabolic flights, and the space shuttle, can all be exploited for different kinds of dust combustion experiments. The present paper describes some recent studies on microgravity combustion of dust suspension carried out on the KC-135 and the Caravelle aircraft. The results reported are obtained from three parabolic flight campaigns.
Drop dynamics in space and interference with acoustic field (M-15)
NASA Technical Reports Server (NTRS)
Yamanaka, Tatsuo
1993-01-01
The objective of the experiment is to study contactless positioning of liquid drops, excitation of capillary waves on the surface of acoustically levitated liquid drops, and deformation of liquid drops by means of acoustic radiation pressure. Contactless positioning technologies are very important in space materials processing because the melt is processed without contacting the wall of a crucible which can easily contaminate the melt specifically for high melting temperatures and chemically reactive materials. Among the contactless positioning technologies, an acoustic technology is especially important for materials unsusceptible to electromagnetic fields such as glasses and ceramics. The shape of a levitated liquid drop in the weightless condition is determined by its surface tension and the internal and external pressure distribution. If the surface temperature is constant and there exist neither internal nor external pressure perturbations, the levitated liquid drop forms a shape of perfect sphere. If temperature gradients on the surface and internal or external pressure perturbations exist, the liquid drop forms various modes of shapes with proper vibrations. A rotating liquid drop was specifically studied not only as a classical problem of theoretical mechanics to describe the shapes of the planets of the solar system, as well as their arrangement, but it is also more a contemporary problem of modern non-linear mechanics. In the experiment, we are expecting to observe various shapes of a liquid drop such as cocoon, tri-lobed, tetropod, multi-lobed, and doughnut.
Deformation twinning of a silver nanocrystal under high pressure. Supplementary materials
Huang, X. J.; Yang, W. G.; Harder, R.; ...
2015-10-20
Within a high-pressure environment, crystal deformation is controlled by complex processes such as dislocation motion, twinning, and phase transitions, which change materials’ microscopic morphology and alter their properties. Likewise, understanding a crystal’s response to external stress provides a unique opportunity for rational tailoring of its functionalities. It is very challenging to track the strain evolution and physical deformation from a single nanoscale crystal under high-pressure stress. Here, we report an in situ three-dimensional mapping of morphology and strain evolutions in a single-crystal silver nanocube within a high-pressure environment using the Bragg Coherent Diffractive Imaging (CDI) method. We also observed amore » continuous lattice distortion, followed by a deformation twining process at a constant pressure. The ability to visualize stress-introduced deformation of nanocrystals with high spatial resolution and prominent strain sensitivity provides an important route for interpreting and engineering novel properties of nanomaterials.« less
NASA Astrophysics Data System (ADS)
Devidas, T. R.; Abhirami, S.; Sharma, Shilpam; Amaladas, E. P.; Mani, Awadhesh
2018-03-01
Studies on the electrical transport properties of the 3D topological insulators Bi2Se3 under iso-electronic substitution of Te at Se sites and the application of external pressure have been performed to understand the evolution of its ground-state properties and to explore possible electronic phase transitions in Bi2Se3‑x Te x (x=0\\text{--}3 ) systems. While the external pressure suppresses the metallic behaviour of Bi2Se3 arising from defect charge carriers leading ultimately to non-metal behaviour, the effect of pressure on Te-doped samples x=1\\text{--}2 seems to be more striking, and causes multiple electronic phase transitions such as an insulator-to-metal transition (MIT) followed by pressure-induced superconducting transition at higher pressures. All the critical parameters such as critical pressure for the occurrence of MIT (PMIT}) , superconductivity (PSC}) and maximum pressure induced superconducting transition temperature (Tc,max}) for given compositions are seen to exhibit maxima at x=1.6 which is the composition that exhibits the most insulating behaviour with least concentration of defect charge carriers among the samples of Bi2Se3‑x Te x (x=0\\text{--}3 ) series. The superconducting transition temperature (Tc}) decreases with increasing pressure in x=1\\text{--}2 samples, while it remains nearly constant for Bi2Te3. Based on the analysis of the experimental data it is surmised that the pressure-induced superconductivity seen in these systems is of conventional (BCS) type.
Definitions of climate and climate change under varying external conditions
NASA Astrophysics Data System (ADS)
Werndl, C.
2014-06-01
Commonly, definitions of climate are endorsed where the external conditions are held constant. This paper argues that these definitions risk being empirically void because in reality the external conditions vary. As a consequence, analogous definitions for varying external conditions are explored with help of the recently developed theory of non-autonomous dynamical systems, and the similarities and differences between the cases of constant and varying external conditions are discussed. It is argued that there are analogous definitions for varying external conditions which are preferable to the definitions where the external conditions are held constant. In this context, a novel definition is proposed (namely, climate as the distribution over time under a regime of varying external conditions), which is argued to be promising.
NASA Astrophysics Data System (ADS)
Zhou, X.; Nolte, D. D.; Pyrak-Nolte, L. J.
2017-12-01
The hysteretic relationship between capillary pressure (Pc) on saturation (S) has been shown to be a projection of a higher-dimensional surface that depends on interfacial area per volume (IAV) as the additional state variable. Most studies that validate the capillary-pressure-saturation-IAV relationship are performed on 2D micro-models or cores where scanning is performed in pressure and not in saturation. We have developed an EWOD technique (electro-wetting on dielectric) to internally manipulate fluid saturation to determine the effect on externally measured pressures. Applying electric fields to electrolytic fluids changes the contact angle among the fluids and the solid. For a parallel-plate electro-wetting set-up, the pressure difference is given by gsl (cosq'EW - cosqEW )/d', where d' is the aperture, qEQ and q'EW are the contact angles before and after the application of voltage, V, and gsl is the interfacial tension between the solid and liquid phases. This pressure difference enables direct control over internal fluid distributions. The contact angle reverts to the original value when V = 0. A sealed micro-model with Electro-Wetting on Dielectric (EWOD) electrodes was fabricated using a PDMS wedge-shaped channel with an entrance width of 1 mm and an exit width of 2 mm. The channel length was 2 mm, and had a depth of 0.9 mm. The PDMS channel was attached to an aluminum plate that served as the ground electrode. An ITO slide coated with PDMS formed the high voltage electrode and was used to seal the micro-model. X-ray Micro-CT scans showed that the contact angle between electrodes changes from from 110˚ (non-wetting) to 70˚ (wetting) for an applied voltage of 318 V AC. By applying voltage to the wedge-shaped micromodel, with the inlet and the outlet opened to the atmosphere, the externally measured capillary pressure remained constant even though the fluid-air interface moved and the saturation increased. For a closed system, the externally measured change in capillary pressure was 30 Pa and the saturation in the channel increased. EWOD provides method to assess the contributions of wettability to the fundamental physics of immiscible fluids in analog porous media. Acknowledgment: This research was supported by the National Science Foundation (1314663-EAR).
Design verification of large time constant thermal shields for optical reference cavities.
Zhang, J; Wu, W; Shi, X H; Zeng, X Y; Deng, K; Lu, Z H
2016-02-01
In order to achieve high frequency stability in ultra-stable lasers, the Fabry-Pérot reference cavities shall be put inside vacuum chambers with large thermal time constants to reduce the sensitivity to external temperature fluctuations. Currently, the determination of thermal time constants of vacuum chambers is based either on theoretical calculation or time-consuming experiments. The first method can only apply to simple system, while the second method will take a lot of time to try out different designs. To overcome these limitations, we present thermal time constant simulation using finite element analysis (FEA) based on complete vacuum chamber models and verify the results with measured time constants. We measure the thermal time constants using ultrastable laser systems and a frequency comb. The thermal expansion coefficients of optical reference cavities are precisely measured to reduce the measurement error of time constants. The simulation results and the experimental results agree very well. With this knowledge, we simulate several simplified design models using FEA to obtain larger vacuum thermal time constants at room temperature, taking into account vacuum pressure, shielding layers, and support structure. We adopt the Taguchi method for shielding layer optimization and demonstrate that layer material and layer number dominate the contributions to the thermal time constant, compared with layer thickness and layer spacing.
Hempfling, H; Husemann, B
1975-06-01
1. Glucose loading tests were undertaken on isolated pancreas or pancreas-duodenal preparations. 2. In 75% of cases a vasodilatation can be observed which leads to enhanced blood circulation under constant pressure in the isolated organ. 3. This vasodilatation persists until the level of blood sugar has normalized. 4. The experiment being carried out on an isolated organ, external factors such as the vagus nerve, do not become active.
A Seafloor Test of the A-0-A Approach to Calibrating Pressure Sensors for Vertical Geodesy
NASA Astrophysics Data System (ADS)
Wilcock, W. S. D.; Manalang, D.; Harrington, M.; Cram, G.; Tilley, J.; Burnett, J.; Martin, D.; Paros, J. M.
2017-12-01
Seafloor geodetic observations are critical for understanding the locking and slip of the megathrust in Cascadia and other subduction zones. Differences of bottom pressure time series have been used successfully in several subduction zones to detect slow-slip earthquakes centered offshore. Pressure sensor drift rates are much greater than the long-term rates of strain build-up and thus, in-situ calibration is required to measure secular strain. One approach to calibration is to use a dead-weight tester, a laboratory apparatus that produces an accurate reference pressure, to calibrate a pressure sensor deployed on the seafloor by periodically switching between the external pressure and the deadweight tester (Cook et al, this session). The A-0-A method replaces the dead weight tester by using the internal pressure of the instrument housing as the reference pressure. We report on the first non-proprietary ocean test of this approach on the MARS cabled observatory at a depth of 900 m depth in Monterey Bay. We use the Paroscientific Seismic + Oceanic Sensors module that is designed for combined geodetic, oceanographic and seismic observations. The module comprises a three-component broadband accelerometer, two pressure sensors that for this deployment measure ocean pressures, A, up to 2000 psia (14 MPa), and a barometer to measure the internal housing reference pressure, 0. A valve periodically switches between external and internal pressures for 5 minute calibrations. The seafloor test started in mid-June and the results of 30 calibrations collected over the first 6 weeks of operation are very encouraging. After correcting for variations in the internal temperature of the housing, the offset of the pressure sensors from the barometer reading as a function of time, can be fit with a straight line for each sensor with a rms misfit of 0.1 hPa (1 mm of water). The slopes of these lines (-4 cm/yr and -0.4 cm/yr) vary by an order of magnitude but the difference in the span (external minus internal pressure) of the two sensors is constant to 0.05 hPa. We will present the results for the first 6 months of A-0-A calibrations for vertical geodesy and also discuss the performance of the pressure sensors and accelerometer for monitoring seismic activity, tilt and ocean infragravity waves.
Skaburskis, M; Helal, R; Zidulka, A
1987-10-01
Patients with noncardiogenic pulmonary edema requiring ventilatory assistance are usually supported with CPPV using positive end-expiratory pressure (PEEP), but CPPV requires endotracheal intubation and may decrease cardiac output (QT). The purpose of this study was to examine thoracoabdominal continuous negative pressure ventilation (CNPV) using external negative end-expiratory pressure (NEEP). The effects on gas exchange and hemodynamics were compared with those of CPPV with PEEP, with the premise that CNPV might sustain venous return and improve QT. In 6 supine, anesthetized and paralyzed dogs with oleic-acid-induced pulmonary edema, 30 min of CNPV was alternated twice with 30 min of CPPV. Positive and negative pressure ventilation were carefully matched for fractional inspired oxygen concentration (FIO2 = 0.56), breathing frequency, and tidal volume. In addition, we matched the increase in delta FRC obtained with the constant distending pressures produced by both modes of ventilation. An average of -9 cm H2O of NEEP produced the same delta FRC as 10.8 cm H2O of PEEP. Gas exchange did not differ significantly between the 2 modes. However, QT was 15.8% higher during CNPV than during CPPV (p less than 0.02). Mixed venous oxygen saturation also improved during CNPV compared with that during CPPV (58.3 versus 54.5%, p less than 0.01). Negative pressure ventilation using NEEP may be a viable alternative to positive pressure ventilation with PEEP in the management of critically ill patients with noncardiogenic pulmonary edema. It offers comparable improvement in gas exchange with the advantages of less cardiac depression and the possible avoidance of endotracheal intubation.
Reconstruction of Pressure Profile Evolution during Levitated Dipole Experiments
NASA Astrophysics Data System (ADS)
Mauel, M.; Garnier, D.; Boxer, A.; Ellsworth, J.; Kesner, J.
2008-11-01
Magnetic levitation of the LDX superconducting dipole causes significant changes in the measured diamagnetic flux and what appears to be an isotropic plasma pressure profile (p˜p||). This poster describes the reconstruction of plasma current and plasma pressure profiles from external measurements of the equilibrium magnetic field, which vary substantially as a function of time depending upon variations in neutral pressure and multifrequency ECRH power levels. Previous free-boundary reconstructions of plasma equilibrium showed the plasma to be anisotropic and highly peaked at the location of the cyclotron resonance of the microwave heating sources. Reconstructions of the peaked plasma pressures confined by a levitated dipole incorporate the small axial motion of the dipole (±5 mm), time varying levitation coil currents, eddy currents flowing in the vacuum vessel, constant magnetic flux linking the superconductor, and new flux loops located near the hot plasma in order to closely couple to plasma current and dipole current variations. I. Karim, et al., J. Fusion Energy, 26 (2007) 99.
46 CFR 154.408 - Cargo tank external pressure load.
Code of Federal Regulations, 2010 CFR
2010-10-01
... minimum internal pressure (maximum vacuum), and the maximum external pressure to which any portion of the... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo tank external pressure load. 154.408 Section 154... Equipment Cargo Containment Systems § 154.408 Cargo tank external pressure load. For the calculation...
Power consumption of rotary blood pumps: pulsatile versus constant-speed mode.
Pirbodaghi, Tohid; Cotter, Chris; Bourque, Kevin
2014-12-01
We investigated the power consumption of a HeartMate III rotary blood pump based on in vitro experiments performed in a cardiovascular simulator. To create artificial-pulse mode, we modulated the pump speed by decreasing the mean speed by 2000 rpm for 200 ms and then increasing speed by 4000 rpm (mean speeds plus 2000 rpm) for another 200 ms, creating a square waveform shape. The HeartMate III was connected to a cardiovascular simulator consisting of a hydraulic pump system to simulate left ventricle pumping action, arterial and venous compliance chambers, and an adjustable valve for peripheral resistance to facilitate the desired aortic pressure. The simulator operated based on Suga's elastance model to mimic the Starling response of the heart, thereby reproducing physiological blood flow and pressure conditions. We measured the instantaneous total electrical current and voltage of the pump to evaluate its power consumption. The aim was to answer these fundamental questions: (i) How does pump speed modulation affect pump power consumption? (ii) How does the power consumption vary in relation to external pulsatile flow? The results indicate that speed modulation and external pulsatile flow both moderately increase the power consumption. Increasing the pump speed reduces the impact of external pulsatile flow. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Parabolic flight - Loss of sense of orientation
NASA Technical Reports Server (NTRS)
Lackner, J. R.; Graybiel, A.
1979-01-01
On the earth, or in level flight, a blindfolded subject being rotated at constant velocity about his recumbent long body axis experiences illusory orbital motion of his body in the opposite direction. By contrast, during comparable rotation in the free-fall phase of parabolic flight, no body motion is perceived and all sense of external orientation may be lost; when touch and pressure stimulation is applied to the body surface, a sense of orientation is reestablished immediately. The increased gravitoinertial force period of a parabola produces an exaggeration of the orbital motion experienced in level flight. These observations reveal an important influence of touch, pressure, and kinesthetic information on spatial orientation and provide a basis for understanding many of the postural illusions reported by astronauts in space flight.
Kornuta, Jeffrey A.; Dixon, J. Brandon
2015-01-01
In addition to external forces, collecting lymphatic vessels intrinsically contract to transport lymph from the extremities to the venous circulation. As a result, the lymphatic endothelium is routinely exposed to a wide range of dynamic mechanical forces, primarily fluid shear stress and circumferential stress, which have both been shown to affect lymphatic pumping activity. Although various ex-vivo perfusion systems exist to study this innate pumping activity in response to mechanical stimuli, none are capable of independently controlling the two primary mechanical forces affecting lymphatic contractility: transaxial pressure gradient, ΔP, which governs fluid shear stress; and average transmural pressure, Pavg, which governs circumferential stress. Hence, the authors describe a novel ex-vivo lymphatic perfusion system (ELPS) capable of independently controlling these two outputs using a linear, explicit model predictive control (MPC) algorithm. The ELPS is capable of reproducing arbitrary waveforms within the frequency range observed in the lymphatics in vivo, including a time-varying ΔP with a constant Pavg, time-varying ΔP and Pavg, and a constant ΔP with a time-varying Pavg. In addition, due to its implementation of syringes to actuate the working fluid, a post-hoc method of estimating both the flow rate through the vessel and fluid wall shear stress over multiple, long (5 sec) time windows is also described. PMID:24809724
49 CFR 195.108 - External pressure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false External pressure. 195.108 Section 195.108... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.108 External pressure. Any external pressure that will be exerted on the...
49 CFR 195.108 - External pressure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false External pressure. 195.108 Section 195.108... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.108 External pressure. Any external pressure that will be exerted on the...
49 CFR 195.108 - External pressure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false External pressure. 195.108 Section 195.108... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.108 External pressure. Any external pressure that will be exerted on the...
49 CFR 195.108 - External pressure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false External pressure. 195.108 Section 195.108... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.108 External pressure. Any external pressure that will be exerted on the...
49 CFR 195.108 - External pressure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false External pressure. 195.108 Section 195.108... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Design Requirements § 195.108 External pressure. Any external pressure that will be exerted on the...
Influence of gaseous hydrogen on the mechanical properties of high temperature alloys
NASA Technical Reports Server (NTRS)
1976-01-01
Tensile tests of six nickel-base and one cobalt-base alloy were conducted in 34.5 MN/sq m helium and hydrogen environments at temperatures from 297 K to 1,088 K. Mechanical properties tests of the nickel-base alloy MAR M-246 (Hf modified), in two cast conditions, were conducted in gaseous environments at temperatures from 297 K to 1,144 K and pressures from one atmosphere to 34.5 MN/sq m. The objective of this program was to obtain the mechanical properties of the various alloys proposed for use in space propulsion systems in a pure hydrogen environment at different temperatures and to compare with the mechanical properties in helium at the same conditions. All testing was conducted on solid specimens exposed to external gaseous pressure. Smooth and notched tensile properties were determined using ASTM tensile testing techniques, and creep-rupture life was determined using ASTM creep-rupture techniques. Low-cycle fatigue life was established by constant total strain and constant stress testing using smooth specimens and a closed-loop test machine.
Bending strength model for internal spur gear teeth
NASA Technical Reports Server (NTRS)
Savage, Michael; Rubadeux, K. L.; Coe, H. H.
1995-01-01
Internal spur gear teeth are normally stronger than pinion teeth of the same pitch and face width since external teeth are smaller at the base. However, ring gears which are narrower have an unequal addendum or are made of a material with a lower strength than that of the meshing pinion may be loaded more critically in bending. In this study, a model for the bending strength of an internal gear tooth as a function of the applied load pressure angle is presented which is based on the inscribed Lewis constant strength parabolic beam. The bending model includes a stress concentration factor and an axial compression term which are extensions of the model for an external gear tooth. The geometry of the Lewis factor determination is presented, the iteration to determine the factor is described, and the bending strength J factor is compared to that of an external gear tooth. This strength model will assist optimal design efforts for unequal addendum gears and gears of mixed materials.
NASA Astrophysics Data System (ADS)
Casini, Leonardo; Funedda, Antonio
2014-09-01
The mylonites of the Baccu Locci Shear Zone (BLSZ), Sardinia (Italy), were deformed during thrusting along a bottom-to-top strain gradient in lower greenschist facies. The microstructure of metavolcanic protoliths shows evidence for composite deformation accommodated by dislocation creep within strong quartz porphyroclasts, and pressure solution in the finer grained matrix. The evolution of mylonite is simulated in two sets of numerical experiments, assuming either a constant width of the deforming zone (model 1) or a narrowing shear zone (model 2). A 2-5 mm y-1 constant-external-velocity boundary condition is applied on the basis of geologic constraints. Inputs to the models are provided by inverting paleostress values obtained from quartz recrystallized grain-size paleopiezometry. Both models predict a significant stress drop across the shear zone. However, model 1 involves a dramatic decrease in strain rate towards the zone of apparent strain localization. In contrast, model 2 predicts an increase in strain rate with time (from 10-14 to 10-12 s-1), which is consistent with stabilization of the shear zone profile and localization of deformation near the hanging wall. Extrapolating these results to the general context of crust strength suggests that pressure-solution creep may be a critical process for strain softening and for the stabilization of deformation within shear zones.
Performance characteristics of two multiaxis thrust-vectoring nozzles at Mach numbers up to 1.28
NASA Technical Reports Server (NTRS)
Wing, David J.; Capone, Francis J.
1993-01-01
The thrust-vectoring axisymmetric (VA) nozzle and a spherical convergent flap (SCF) thrust-vectoring nozzle were tested along with a baseline nonvectoring axisymmetric (NVA) nozzle in the Langley 16-Foot Transonic Tunnel at Mach numbers from 0 to 1.28 and nozzle pressure ratios from 1 to 8. Test parameters included geometric yaw vector angle and unvectored divergent flap length. No pitch vectoring was studied. Nozzle drag, thrust minus drag, yaw thrust vector angle, discharge coefficient, and static thrust performance were measured and analyzed, as well as external static pressure distributions. The NVA nozzle and the VA nozzle displayed higher static thrust performance than the SCF nozzle throughout the nozzle pressure ratio (NPR) range tested. The NVA nozzle had higher overall thrust minus drag than the other nozzles throughout the NPR and Mach number ranges tested. The SCF nozzle had the lowest jet-on nozzle drag of the three nozzles throughout the test conditions. The SCF nozzle provided yaw thrust angles that were equal to the geometric angle and constant with NPR. The VA nozzle achieved yaw thrust vector angles that were significantly higher than the geometric angle but not constant with NPR. Nozzle drag generally increased with increases in thrust vectoring for all the nozzles tested.
Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.
Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth
2015-10-01
Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by Daedalus Enterprises.
NASA Astrophysics Data System (ADS)
Hamed, A. E.; Kassem, M. E.; El-Wahidy, E. F.; El-Abshehy, M. A.
1995-03-01
The temperature dependence of specific heat at constant pressure, Cp(T), has been measured for lithium sodium sulphate, LiNaSo4 crystals, at different ?-radiation doses and external bias electric field (Eb), in the temperature range 300-900 K. A nonlinear dependence of transition temperature, T1 and a remarkable change in the thermodynamic parameters, were obtained as the effect of both electric field and ?-radiation. The effect of ?-radiation doses on the phase transition in LiNaSO4 crystals was explained as due to an internal bias field, Eb, originating from the interaction of polar defects with the order parameter of the host lattice. The internal bias field effect on the behaviour of Cp(T) in LiNaSO4 crystals was similar to that of the external electric field (E).
NASA Astrophysics Data System (ADS)
Zhu, Haiyan; Shi, Liwei; Li, Shuaiqi; Duan, Yifeng; Zhang, Shaobo; Xia, Wangsuo
2018-04-01
The effects of hydrostatic pressure and biaxial strains on the elastic and electronic properties of a superhard material t-C8B2N2 have been studied using first-principles calculations. The structure is proven to be mechanically and dynamically stable under the applied external forces. All the elastic constants (except C66) and elastic modulus increase (decrease) with increasing pressure and compressive (tensile) biaxial strain ɛxx. A microscopic model is used to calculate the Vicker's hardness of every single bond as well as the crystal. The hardness of t-C8B2N2 (64.7 GPa) exceeds that of c-BN (62 GPa) and increases obviously by employing pressure and compressive ɛxx. Furthermore, the Debye temperature and anisotropy of sound velocities for t-C8B2N2 have been discussed. t-C8B2N2 undergoes an indirect to direct bandgap transition when ɛxx > 2%; however, the indirect bandgap character of the material remains under pressure.
Computational Study of Axisymmetric Off-Design Nozzle Flows
NASA Technical Reports Server (NTRS)
DalBello, Teryn; Georgiadis, Nicholas; Yoder, Dennis; Keith, Theo
2003-01-01
Computational Fluid Dynamics (CFD) analyses of axisymmetric circular-arc boattail nozzles operating off-design at transonic Mach numbers have been completed. These computations span the very difficult transonic flight regime with shock-induced separations and strong adverse pressure gradients. External afterbody and internal nozzle pressure distributions computed with the Wind code are compared with experimental data. A range of turbulence models were examined, including the Explicit Algebraic Stress model. Computations have been completed at freestream Mach numbers of 0.9 and 1.2, and nozzle pressure ratios (NPR) of 4 and 6. Calculations completed with variable time-stepping (steady-state) did not converge to a true steady-state solution. Calculations obtained using constant timestepping (timeaccurate) indicate less variations in flow properties compared with steady-state solutions. This failure to converge to a steady-state solution was the result of using variable time-stepping with large-scale separations present in the flow. Nevertheless, time-averaged boattail surface pressure coefficient and internal nozzle pressures show reasonable agreement with experimental data. The SST turbulence model demonstrates the best overall agreement with experimental data.
Computations of Internal and External Axisymmetric Nozzle Aerodynamics at Transonic Speeds
NASA Technical Reports Server (NTRS)
Dalbello, Teryn; Georgiadis, Nicholas; Yoder, Dennis; Keith, Theo
2003-01-01
Computational Fluid Dynamics (CFD) analyses of axisymmetric circular-arc boattail nozzles have been completed in support of NASA's Next Generation Launch Technology Program to investigate the effects of high-speed nozzle geometries on the nozzle internal flow and the surrounding boattail regions. These computations span the very difficult transonic flight regime, with shock-induced separations and strong adverse pressure gradients. External afterbody and internal nozzle pressure distributions computed with the Wind code are compared with experimental data. A range of turbulence models were examined in Wind, including an Explicit Algebraic Stress model (EASM). Computations on two nozzle geometries have been completed at freestream Mach numbers ranging from 0.6 to 0.9, driven by nozzle pressure ratios (NPR) ranging from 2.9 to 5. Results obtained on converging-only geometry indicate reasonable agreement to experimental data, with the EASM and Shear Stress Transport (SST) turbulence models providing the best agreement. Calculations completed on a converging-diverging geometry involving large-scale internal flow separation did not converge to a true steady-state solution when run with variable timestepping (steady-state). Calculations obtained using constant timestepping (time-accurate) indicate less variations in flow properties compared with steady-state solutions. This failure to converge to a steady-state solution was found to be the result of difficulties in using variable time-stepping with large-scale separations present in the flow. Nevertheless, time-averaged boattail surface pressure coefficient and internal nozzle pressures show fairly good agreement with experimental data. The SST turbulence model demonstrates the best over-all agreement with experimental data.
Cosgrove, D J; Van Volkenburgh, E; Cleland, R E
1984-01-01
Theory predicts that, for growing plant cells isolated from a supply of water, stress relaxation of the cell wall should decrease cell turgor pressure (P) until the yield threshold for cell explanation is reached. This prediction was tested by direct P measurements of pea (Pisum sativum L.) stem cortical cells before and after excision of the growing region and isolation of the growing tissue from an external water supply. Cell P was measured with the micro-pressure probe under conditions which eliminated transpiration. Psychrometric measurements of water potential confirmed the pressure-probe measurements. Following excision, P of the growing cells decreased in 1 h by an average of 1.8 bar to a mean plateau value of 2.8 bar, and remained constant thereafter. Treatment with 10(-5) M indole-3-acetic acid or 10(-5) M fusicoccin (known growth stimulants) accelerated the rate of P relaxation, whereas various treatments which inhibit growth slowed down or completely stopped P relaxation in apical segments. In contrast, P of basal (nongrowing) segments gradually increased because of absorption of solutes from the cell-wall free space of the tissue. Such solute absorption also occurred in apical segments, but wall relaxation held P at the yield threshold in those segments which were isolated from an external water supply. These results provide a new and rapid method for measuring the yield threshold and they show that P in intact growing pea stems exceeds the yield threshold by about 2 bar. Wall relaxation is shown here to affect the water potential and turgor pressure of excised growing segments. In addition, solute release and absorption upon excision may influence the water potential and turgor pressure of nongrowing excised plant tissues.
NASA Technical Reports Server (NTRS)
Barton, J. E.; Patterson, H. W.
1973-01-01
An analysis of transient pressures in externally pressurized cryogenic hydrogen and oxygen tanks was conducted and the effects of design variables on pressure response determined. The analysis was conducted with a computer program which solves the compressible viscous flow equations in two-dimensional regions representing the tank and external loop. The external loop volume, thermal mass, and heat leak were the dominant design variables affecting the system pressure response. No significant temperature stratification occurred in the fluid contained in the tank.
The Bulging Behavior of Thick-Walled 6063 Aluminum Alloy Tubes Under Double-Sided Pressures
NASA Astrophysics Data System (ADS)
Cui, Xiao-Lei; Wang, Xiao-Song; Yuan, Shi-Jian
2015-05-01
To make further exploration on the deformation behavior of tube under double-sided pressures, the thick-walled 6063 aluminum alloy tubes with an outer diameter of 65 mm and an average thickness of 7.86 mm have been used to be bulged under the combined action of internal and external pressures. In the experiment, two ends of the thick-walled tubes were fixed using the tooth and groove match. Three levels of external pressure (0 MPa, 40 MPa, and 80 MPa), in conjunction with the internal pressure, were applied on the tube outside and inside simultaneously. The effect of external pressure on the bulging behavior of the thick-walled tubes, such as the limiting expansion ratio, the bulging zone profile, and the thickness distribution, has been investigated. It is shown that the limiting expansion ratio, the bulging zone profile, and the thickness distribution in the homogeneous bulging area are all insensitive to the external pressure. However, the external pressure can make the thick-walled tube achieve a thinner wall at the fracture area. It reveals that the external pressure can only improve the fracture limit of the thick-walled 6063 tubes, but it has very little effect on their homogeneous bulging behavior. It might be because the external pressure can only increase the magnitude of the hydrostatic pressure for the tube but has no effect on the Lode parameter.
Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois A; Guiochon, Georges
2014-01-17
Five methods for controlling the mobile phase flow rate for gradient elution analyses using very high pressure liquid chromatography (VHPLC) were tested to determine thermal stability of the column during rapid gradient separations. To obtain rapid separations, instruments are operated at high flow rates and high inlet pressure leading to uneven thermal effects across columns and additional time needed to restore thermal equilibrium between successive analyses. The purpose of this study is to investigate means to minimize thermal instability and obtain reliable results by measuring the reproducibility of the results of six replicate gradient separations of a nine component RPLC standard mixture under various experimental conditions with no post-run times. Gradient separations under different conditions were performed: constant flow rates, two sets of constant pressure operation, programmed flow constant pressure operation, and conditions which theoretically should yield a constant net heat loss at the column's wall. The results show that using constant flow rates, programmed flow constant pressures, and constant heat loss at the column's wall all provide reproducible separations. However, performing separations using a high constant pressure with programmed flow reduces the analysis time by 16% compared to constant flow rate methods. For the constant flow rate, programmed flow constant pressure, and constant wall heat experiments no equilibration time (post-run time) was required to obtain highly reproducible data. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Piscesa, B.; Attard, M. M.; Suprobo, P.; Samani, A. K.
2017-11-01
External confining devices are often used to enhance the strength and ductility of reinforced concrete columns. Among the available external confining devices, steel tube is one of the most widely used in construction. However, steel tube has some drawbacks such as local buckling which needs to be considered when estimating the axial load carrying capacity of the concrete-filled-steel-tube (CFST) column. To tackle this problem in design, Eurocode 4 provided guidelines to estimate the effective yield strength of the steel tube material. To study the behavior of CFST column, in this paper, a non-linear analysis using a fiber-based approach was conducted. The use of the fiber-based approach allows the engineers to predict not only the axial load carrying capacity but also the complete load-deformation curve of the CFST columns for a known confining pressure. In the proposed fiber-based approach, an inverse analysis is used to estimate the constant confining pressure similar to design-oriented models. This paper also presents comparisons between the fiber-based approach model with the experimental results and the 3D non-linear finite element analysis.
Constant-pH molecular dynamics using stochastic titration
NASA Astrophysics Data System (ADS)
Baptista, António M.; Teixeira, Vitor H.; Soares, Cláudio M.
2002-09-01
A new method is proposed for performing constant-pH molecular dynamics (MD) simulations, that is, MD simulations where pH is one of the external thermodynamic parameters, like the temperature or the pressure. The protonation state of each titrable site in the solute is allowed to change during a molecular mechanics (MM) MD simulation, the new states being obtained from a combination of continuum electrostatics (CE) calculations and Monte Carlo (MC) simulation of protonation equilibrium. The coupling between the MM/MD and CE/MC algorithms is done in a way that ensures a proper Markov chain, sampling from the intended semigrand canonical distribution. This stochastic titration method is applied to succinic acid, aimed at illustrating the method and examining the choice of its adjustable parameters. The complete titration of succinic acid, using constant-pH MD simulations at different pH values, gives a clear picture of the coupling between the trans/gauche isomerization and the protonation process, making it possible to reconcile some apparently contradictory results of previous studies. The present constant-pH MD method is shown to require a moderate increase of computational cost when compared to the usual MD method.
Pressure effects on the electronic properties in CeCoIn5: A first-principle study
NASA Astrophysics Data System (ADS)
Medeiros, Gustavo; Gonzalez, J. L.; Scopel, Wanderlã L.
2017-11-01
Superconducting heavy fermions are exotic materials with strong electronic correlations. The temperature-pressure phase diagrams of some of these materials show a complex interplay between superconductivity and magnetism that is essential to understand the physical properties of these systems. In this work, first principle calculations are performed in order to study the pressure effects on the electronic correlations in the CeCoIn5 system, which is superconducting at ambient pressure with Tc = 2.3 K. The density functional theory (DFT) method was used to include on-site coulomb repulsions (U) at the d (Co and In) and f (Ce) electrons of the CeCoIn5 compound. External applied pressures were simulated by correlating an applied pressure with a reduction of the volume of the unit cell, but keeping constant the c/a relation, as reported in experiments. Our findings reveal that the U parameters for all atomic species increase linearly with the pressure (P), being this effect higher for the f-electrons of the cerium ions, where dU / dP = 1.2 eV/GPa. In summary, these results not only suggest that the pressure effect can be correlated with an increase in the electronic correlations in the CeCoIn5 compound, as also, the work allows quantify this effect.
46 CFR 64.19 - External pressure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... HANDLING SYSTEMS Standards for an MPT § 64.19 External pressure. (a) A tank without a vacuum breaker must be designed to withstand an external pressure of 71/2 psig or more. (b) A tank with a vacuum breaker...
46 CFR 64.19 - External pressure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... HANDLING SYSTEMS Standards for an MPT § 64.19 External pressure. (a) A tank without a vacuum breaker must be designed to withstand an external pressure of 71/2 psig or more. (b) A tank with a vacuum breaker...
46 CFR 64.19 - External pressure.
Code of Federal Regulations, 2014 CFR
2014-10-01
... HANDLING SYSTEMS Standards for an MPT § 64.19 External pressure. (a) A tank without a vacuum breaker must be designed to withstand an external pressure of 71/2 psig or more. (b) A tank with a vacuum breaker...
46 CFR 64.19 - External pressure.
Code of Federal Regulations, 2011 CFR
2011-10-01
... HANDLING SYSTEMS Standards for an MPT § 64.19 External pressure. (a) A tank without a vacuum breaker must be designed to withstand an external pressure of 71/2 psig or more. (b) A tank with a vacuum breaker...
46 CFR 64.19 - External pressure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... HANDLING SYSTEMS Standards for an MPT § 64.19 External pressure. (a) A tank without a vacuum breaker must be designed to withstand an external pressure of 71/2 psig or more. (b) A tank with a vacuum breaker...
Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces
NASA Astrophysics Data System (ADS)
David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth
2015-04-01
We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.
David, Grégory; Esat, Kıvanç; Hartweg, Sebastian; Cremer, Johannes; Chasovskikh, Egor; Signorell, Ruth
2015-04-21
We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.
NASA Technical Reports Server (NTRS)
Wingett, Paul (Inventor)
2001-01-01
A mounting assembly for mounting a composite pressure vessel to a vehicle includes a saddle having a curved surface extending between two pillars for receiving the vessel. The saddle also has flanged portions which can be bolted to the vehicle. Each of the pillars has hole in which is mounted the shaft portion of an attachment member. A resilient member is disposed between each of the shaft portions and the holes and loaded by a tightening nut. External to the holes, each of the attachment members has a head portion to which a steel band is attached. The steel band circumscribes the vessel and translates the load on the springs into a clamping force on the vessel. As the vessel expands and contracts, the resilient members expand and contract so that the clamping force applied by the band to the vessel remains constant.
Critical behavior and phase transition of dilaton black holes with nonlinear electrodynamics
NASA Astrophysics Data System (ADS)
Dayyani, Z.; Sheykhi, A.; Dehghani, M. H.; Hajkhalili, S.
2018-02-01
In this paper, we take into account the dilaton black hole solutions of Einstein gravity in the presence of logarithmic and exponential forms of nonlinear electrodynamics. First of all, we consider the cosmological constant and nonlinear parameter as thermodynamic quantities which can vary. We obtain thermodynamic quantities of the system such as pressure, temperature and Gibbs free energy in an extended phase space. We complete the analogy of the nonlinear dilaton black holes with the Van der Waals liquid-gas system. We work in the canonical ensemble and hence we treat the charge of the black hole as an external fixed parameter. Moreover, we calculate the critical values of temperature, volume and pressure and show that they depend on the dilaton coupling constant as well as on the nonlinear parameter. We also investigate the critical exponents and find that they are universal and independent of the dilaton and nonlinear parameters, which is an expected result. Finally, we explore the phase transition of nonlinear dilaton black holes by studying the Gibbs free energy of the system. We find that in the case of T>T_c, we have no phase transition. When T=T_c, the system admits a second-order phase transition, while for T=T_f
Clinical significance of stapedioplasty biomechanics: swimming, diving, flying after stapes surgery.
Hüttenbrink, Karl-Bernd
2007-01-01
A piston prosthesis in stapedioplasty significantly modifies the function of the normal ossicular chain. Due to the fact that the ear works as a pressure receptor, a piston prosthesis will be displaced at ambient air pressure changes in a different way than the normal stapes. Our ear is constantly exposed to these pressure changes in daily live, for example during swallowing, with tubal opening, with wind gusts at the external ear, during flying, or diving. Temporal bone experiments showed that elevated static pressures, like in tympanometry, can displace a piston up to 0.5mm in the vestibule. These large movements, which are caused by the missing attachment of the piston to the annual ligament, may explain why a short piston can be lifted out of the footplate perforation (e.g. after sneezing) or a piston with excessive length might come into contact with the membranous labyrinth, causing vertigo with an inward movement. Flying or diving can be performed by the patients after stapedioplasty, provided that a test with tympanometry is tolerated without evoking vertigo.
Molecular dynamics study of vacancy-like defects in a model glass : static behaviour
NASA Astrophysics Data System (ADS)
Delaye, J. M.; Limoge, Y.
1993-10-01
The possibility of defining vacancy-like defects in a Lennard-Jones glass is searched for in a systematic manner. Considering different relaxation levels of the same system, as well as different external pressures, we use a Molecular Dynamics simulation method, to study at constant volume or external pressure, the relaxation of a “piece” of glass, after the sudden removal of an atom. Three typical kinds of behaviour can be observed: the persistence of the empty volume left by the missing atom, its migration by clearly identifiable atomic jumps and the dissipation “on the spot”. A careful analysis of the probabilities of these three kinds of behaviour shows that a meaningful definition of vacancy-like defects can be given in a Lennard-Jones glass. Dans cet article, nous nous penchons de façon systématique sur la possibilité de définir des défauts de type lacunaire dans un verre de Lennard-Jones, à différents niveaux de relaxation et de pression, par une méthode de simulation numérique en dynamique moléculaire à volume ou à pression constants. Le défaut est créé en supprimant un atome et en suivant la réponse du système. Nous observons trois comportements typiques : la persistance sur place du “trou” laissé par l'atome supprimé, sa migration par des sauts atomiques clairement identifiés et enfin sa dissipation sur place. Une analyse détaillée de ces trois comportements montre qu'il est possible dans un verre de Lennard-Jones de définir des défauts de type lacunaire.
NASA Astrophysics Data System (ADS)
Mishra, Karuna Kara; Bevara, Samatha; Ravindran, T. R.; Patwe, S. J.; Gupta, Mayanak K.; Mittal, Ranjan; Krishnan, R. Venkata; Achary, S. N.; Tyagi, A. K.
2018-02-01
Herein we reported structural stability, vibrational and thermal properties of K2Ce[PO4]2, a relatively underexplored complex phosphate of tetravalent Ce4+ from in situ high-pressure Raman spectroscopic investigations up to 28 GPa using a diamond anvil cell. The studies identified the soft phonons that lead to a reversible phase transformation above 8 GPa, and a phase coexistence of ambient (PI) and high pressure (PII) phases in a wider pressure region 6-11 GPa. From a visual representation of the computed eigen vector displacements, the Ag soft mode at 82 cm-1 is assigned as a lattice mode of K+ cation. Pressure-induced positional disorder is apparent from the substantial broadening of internal modes and the disappearance of low frequency lattice and external modes in phase PII above 18 GPa. Isothermal mode Grüneisen parameters γi of the various phonon modes are calculated and compared for several modes. Using these values, thermal properties such as average Grüneisen parameter, and thermal expansion coefficient are estimated as 0.47, and 2.5 × 10-6 K-1, respectively. The specific heat value was estimated from all optical modes obtained from DFT calculations as 314 J-mol-1 K-1. Our earlier reported temperature dependence of phonon frequencies is used to decouple the "true anharmonic" (explicit contribution at constant volume) and "quasi harmonic" (implicit contribution brought out by volume change) contributions from the total anharmonicity. In addition to the 81 cm-1 Ag lattice mode, several other lattice and external modes of PO43- ions are found to be strongly anharmonic.
NASA Astrophysics Data System (ADS)
Rubio, Rafael M.; Salamanca, Juan J.
2018-07-01
The dynamics of external force free motion of pendulums on surfaces of constant Gaussian curvature is addressed when the pivot moves along a geodesic obtaining the Lagrangian of the system. As an application it is possible the study of elastic and quantum pendulums.
Dynamic Characteristics of The DSI-Type Constant-Flow Valves
NASA Astrophysics Data System (ADS)
Kang, Yuan; Hu, Sheng-Yan; Chou, Hsien-Chin; Lee, Hsing-Han
Constant flow valves have been presented in industrial applications or academic studies, which compensate recess pressures of a hydrostatic bearing to resist load fluctuating. The flow rate of constant-flow valves can be constant in spite of the pressure changes in recesses, however the design parameters must be specified. This paper analyzes the dynamic responses of DSI-type constant-flow valves that is designed as double pistons on both ends of a spool with single feedback of working pressure and regulating restriction at inlet. In this study the static analysis presents the specific relationships among design parameters for constant flow rate and the dynamic analyses give the variations around the constant flow rate as the working pressure fluctuates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guan, Jiwen; Song, Yang, E-mail: yang.song@uwo.ca; Department of Chemistry, University of Western Ontario, London, Ontario N6A 5B7
The polymerization process of condensed styrene to produce polystyrene as an industrially important polymeric material was investigated using a novel approach by combining external compression with ultraviolet radiation. The reaction evolution was monitored as a function of time and the reaction products were characterized by in situ Fourier transform infrared spectroscopy. By optimizing the loading pressures, we observed highly efficient and selective production of polystyrene of different tacticities. Specifically, at relatively low loading pressures, infrared spectra suggest that styrene monomers transform to amorphous atactic polystyrene (APS) with minor crystalline isotactic polystyrene. In contrast, APS was found to be the solemore » product when polymerization occurs at relatively higher loading pressures. The time-dependent reaction profiles allow the examination of the polymerization kinetics by analyzing the rate constant and activation volume as a function of pressure. As a result, an optimized pressure condition, which allows a barrierless reaction to proceed, was identified and attributed to the very desirable reaction yield and kinetics. Finally, the photoinitiated reaction mechanism and the growth geometry of the polymer chains were investigated from the energy diagram of styrene and by the topology analysis of the crystal styrene. This study shows strong promise to produce functional polymeric materials in a highly efficient and controlled manner.« less
Junicke, H; Feldman, H; van Loosdrecht, M C M; Kleerebezem, R
2015-04-01
In this study, the impact of the hydrogen partial pressure on lactate degradation was investigated in a coculture of Desulfovibrio sp. G11 and Methanobrevibacter arboriphilus DH1. To impose a change of the hydrogen partial pressure, formate was added to the reactor. Hydrogen results from the bioconversion of formate besides lactate in the liquid phase. In the presence of a hydrogen-consuming methanogen, this approach allows for a better estimation of low dissolved hydrogen concentrations than under conditions where hydrogen is supplied externally from the gas phase, resulting in a more accurate determination of kinetic parameters. A change of the hydrogen partial pressure from 1,200 to 250 ppm resulted in a threefold increase of the biomass-specific lactate consumption rate. The 50 % inhibition constant of hydrogen on lactate degradation was determined as 0.692 ± 0.064 μM dissolved hydrogen (831 ± 77 ppm hydrogen in the gas phase). Moreover, for the first time, the maximum biomass-specific lactate consumption rate of Desulfovibrio sp. G11 (0.083 ± 0.006 mol-Lac/mol-XG11/h) and the affinity constant for hydrogen uptake of Methanobrevibacter arboriphilus DH1 (0.601 ± 0.022 μM dissolved hydrogen) were determined. Contrary to the widely established view that the biomass-specific growth rate of a methanogenic coculture is determined by the hydrogen-utilizing partner; here, it was found that the hydrogen-producing bacterium determined the biomass-specific growth rate of the coculture grown on lactate and formate.
Direct measurement of asperity contact growth in quartz at hydrothermal conditions
Beeler, Nicholas M.; Hickman, Stephen H.
2015-01-01
Earthquake recurrence requires interseismic fault restrengthening which results from solid state deformation in room-temperature friction and indentation experiments. In contrast exhumed fault zones show solution-transport processes such as pressure solution and contact overgrowths influence fault zone properties . In the absence of fluid flow, overgrowths are driven by gradients in surface curvature where material is dissolved, diffuses, and precipitates at the contact without convergence normal to the contact. To determine the rate of overgrowth for quartz, we conducted single contact experiments in an externally heated pressure vessel. Convergence was continuously monitored using reflected-light interferometry through a long-working-distance microscope. Contact normal force was constant with an initial effective normal stress of 1.7 MPa, temperature was between 350 and 530{degree sign}C, and water pressure was constant at 150 MPa. Two control experiments were conducted: one dry at 425{degree sign}C and one bi-material (sapphire) at 425{degree sign}C and 150 MPa water pressure. No contact growth or convergence was observed in the controls. For wet single-phase contacts, growth was initially rapid and then decreased with time. No convergence was observed. Fluid inclusions indicate that the contact is not uniformly wetted. The contact is bounded by small regions of high aperture, reflecting local free-face dissolution as the source for the overgrowth. The apparent activation energy is ~125 kJ/mol. Extrapolation predicts rates of contact area increase orders of magnitude faster than in dry, room-temperature and hydrothermal friction experiments, suggesting that natural strength recovery near the base of the seismogenic zone could be dominated by contact overgrowth.
21 CFR 868.5935 - External negative pressure ventilator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ventilator. (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a device chamber that is intended to support a patient's ventilation by alternately applying and releasing external negative pressure over the diaphragm and upper trunk of the patient. (b) Classification. Class II...
Mouser, J Grant; Ade, Carl J; Black, Christopher D; Bemben, Debra A; Bemben, Michael G
2018-05-01
Blood flow restriction (BFR), the application of external pressure to occlude venous return and restrict arterial inflow, has been shown to increase muscular size and strength when combined with low-load resistance exercise. BFR in the research setting uses a wide range of pressures, applying a pressure based upon an individual's systolic pressure or a percentage of occlusion pressure; not a directly determined reduction in blood flow. The relationship between relative pressure and blood flow has not been established. To measure blood flow in the arm under relative levels of BFR. Forty-five people (18-40 years old) participated. Arterial occlusion pressure in the right arm was measured using a 5-cm pneumatic cuff. Blood flow in the brachial artery was measured at rest and at pressures between 10% and 90% of occlusion using ultrasound. Blood flow decreased in a nonlinear, stepped fashion. Blood flow decreased at 10% of occlusion and remained constant until decreasing again at 40%, where it remained until 90% of occlusion. The decrease in brachial blood flow is not proportional to the applied relative pressure. The prescription of blood flow restriction should take into account the stimulus provided at each relative level of blood flow. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Stability of aerosol droplets in Bessel beam optical traps under constant and pulsed external forces
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Grégory; Esat, Kıvanç; Hartweg, Sebastian
We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance formore » the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.« less
Effect of initial conditions on combustion generated loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tieszen, S.R.
1991-01-01
This analytical study examines the effect of initial thermodynamic conditions on the loads generated by the combustion of homogeneous hydrogen-air-steam mixtures. The effect of initial temperature, pressure, hydrogen concentration, and steam concentration is evaluated for two cases, (1) constant volume and (2) constant initial pressure. For each case, the Adiabatic, Isochoric, Complete Combustion (AICC), Chapman-Jouguet (CJ), and normally reflected CJ pressures are calculated for a range of hydrogen and steam concentrations representative of the entire flammable regime. For detonation loads, pressure profiles and time-histories are also evaluated in one-dimensional Cartesian geometry. The results show that to a first approximation, themore » AICC and CJ pressures are directly proportional to the initial density. Increasing the hydrogen concentration up to stoichiometric concentrations significantly increases the AICC, CJ, and reflected CJ pressures. For the constant volume case, the AICC, CJ, and reflected CJ pressures increase with increasing hydrogen concentration on the rich side of stoichiometric concentrations. For the constant initial pressure case, the AICC, CJ and reflected CJ pressures decrease with increasing hydrogen concentration on the rich side of stoichiometric values. The addition of steam decreases the AICC, CJ and reflected CJ pressures for the constant initial pressure case, but increases them for the constant volume case. For detonations, the pressure time-histories can be normalized with the AICC pressure and the reverberation time for Cartesian geometry. 35 refs., 16 figs.« less
Highly efficient and selective pressure-assisted photon-induced polymerization of styrene
NASA Astrophysics Data System (ADS)
Guan, Jiwen; Song, Yang
2016-06-01
The polymerization process of condensed styrene to produce polystyrene as an industrially important polymeric material was investigated using a novel approach by combining external compression with ultraviolet radiation. The reaction evolution was monitored as a function of time and the reaction products were characterized by in situ Fourier transform infrared spectroscopy. By optimizing the loading pressures, we observed highly efficient and selective production of polystyrene of different tacticities. Specifically, at relatively low loading pressures, infrared spectra suggest that styrene monomers transform to amorphous atactic polystyrene (APS) with minor crystalline isotactic polystyrene. In contrast, APS was found to be the sole product when polymerization occurs at relatively higher loading pressures. The time-dependent reaction profiles allow the examination of the polymerization kinetics by analyzing the rate constant and activation volume as a function of pressure. As a result, an optimized pressure condition, which allows a barrierless reaction to proceed, was identified and attributed to the very desirable reaction yield and kinetics. Finally, the photoinitiated reaction mechanism and the growth geometry of the polymer chains were investigated from the energy diagram of styrene and by the topology analysis of the crystal styrene. This study shows strong promise to produce functional polymeric materials in a highly efficient and controlled manner.
Kartamyshev, Sergey P; Balashov, Sergey A; Melkumyants, Arthur M
2007-01-01
The effect of shear stress at the endothelium in the attenuation of the noradrenaline-induced constriction of the femoral vascular bed perfused at a constant blood flow was investigated in 16 anesthetized cats. It is known that the adrenergic vasoconstriction of the femoral vascular bed is considerably greater at a constant pressure perfusion than at a constant blood flow. This difference may depend on the ability of the endothelium to relax smooth muscle in response to an increase in wall shear stress. Since the shear stress is directly related to the blood flow and inversely related to the third power of vessel diameter, vasoconstriction at a constant blood flow increases the wall shear stress that is the stimulus for smooth muscle relaxation opposing constriction. On the other hand, at a constant perfusion pressure, vasoconstriction is accompanied by a decrease in flow rate, which prevents a wall shear stress increase. To reveal the effect of endothelial sensitivity to shear stress, we compared noradrenaline-induced changes in total and proximal arterial resistances during perfusion of the hind limb at a constant blood flow and at a constant pressure in vessels with intact and injured endothelium. We found that in the endothelium-intact bed the same concentration of noradrenaline at a constant flow caused an increase in overall vascular peripheral resistance that was half as large as at a constant perfusion pressure. This difference is mainly confined to the proximal arterial vessels (arteries and large arterioles) whose resistance at a constant flow increased only 0.19 +/- 0.03 times compared to that at a constant pressure. The removal of the endothelium only slightly increased constrictor responses at the perfusion under a constant pressure (noradrenaline-induced increases of both overall and proximal arterial resistance augmented by 12%), while the responses of the proximal vessels at a constant flow became 4.7 +/- 0.4 times greater than in the endothelium-intact bed. A selective blockage of endothelium sensitivity to shear stress using a glutaraldehyde dimer augmented the constrictor responses of the proximal vessels at a constant flow 4.6-fold (+/-0.3), but had no significant effect on the responses at a constant pressure. These results are consistent with the conclusion that the difference in constrictor responses at constant flow and pressure perfusions depends mainly on the smooth muscle relaxation caused by increased wall shear stress. Copyright (c) 2007 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Ruan, Zhongyuan; Iñiguez, Gerardo; Karsai, Márton; Kertész, János
2015-11-01
Diffusion of information, behavioral patterns or innovations follows diverse pathways depending on a number of conditions, including the structure of the underlying social network, the sensitivity to peer pressure and the influence of media. Here we study analytically and by simulations a general model that incorporates threshold mechanism capturing sensitivity to peer pressure, the effect of "immune" nodes who never adopt, and a perpetual flow of external information. While any constant, nonzero rate of dynamically introduced spontaneous adopters leads to global spreading, the kinetics by which the asymptotic state is approached shows rich behavior. In particular, we find that, as a function of the immune node density, there is a transition from fast to slow spreading governed by entirely different mechanisms. This transition happens below the percolation threshold of network fragmentation, and has its origin in the competition between cascading behavior induced by adopters and blocking due to immune nodes. This change is accompanied by a percolation transition of the induced clusters.
Radiative-photochemical response of the mesosphere to dynamical forcing
NASA Technical Reports Server (NTRS)
Frederick, J. E.
1981-01-01
Combination of the chemical continuity equation for odd oxygen with the second law of thermodynamics yields analytic solutions which describe the coupled behavior of temperature and ozone perturbations in response to an externally specified forcing. The results appear in a form which allows easy physical interpretation of the coupling between radiative and photochemical processes. When the forcing is chosen to mimic a planetary scale wave, the theory shows that photochemical acceleration of radiative damping reduces the amplitude of the temperature perturbation by an amount which increases with the wave period. Although ozone fluctuations are anti-correlated with those in temperature, minima in ozone do not coincide exactly in longitude with temperature maxima. The percentage variation in ozone increases upward and is always larger than that in temperature at the same pressure. This demonstrates that variations in ozone on constant pressure surfaces may serve as a sensitive indicator of wave activity in the mesosphere.
Microfabricated injectable drug delivery system
Krulevitch, Peter A.; Wang, Amy W.
2002-01-01
A microfabricated, fully integrated drug delivery system capable of secreting controlled dosages of multiple drugs over long periods of time (up to a year). The device includes a long and narrow shaped implant with a sharp leading edge for implantation under the skin of a human in a manner analogous to a sliver. The implant includes: 1) one or more micromachined, integrated, zero power, high and constant pressure generating osmotic engine; 2) low power addressable one-shot shape memory polymer (SMP) valves for switching on the osmotic engine, and for opening drug outlet ports; 3) microfabricated polymer pistons for isolating the pressure source from drug-filled microchannels; 4) multiple drug/multiple dosage capacity, and 5) anisotropically-etched, atomically-sharp silicon leading edge for penetrating the skin during implantation. The device includes an externally mounted controller for controlling on-board electronics which activates the SMP microvalves, etc. of the implant.
NASA Astrophysics Data System (ADS)
Xiao-Lin, Zhang; Yuan-Yuan, Wu; Xiao-Hong, Shao; Yong, Lu; Ping, Zhang
2016-05-01
The high pressure behaviors of Th4H15 and ThH2 are investigated by using the first-principles calculations based on the density functional theory (DFT). From the energy-volume relations, the bct phase of ThH2 is more stable than the fcc phase at ambient conditions. At high pressure, the bct ThH2 and bcc Th4H15 phases are more brittle than they are at ambient pressure from the calculated elastic constants and the Poisson ratio. The thermodynamic stability of the bct phase ThH2 is determined from the calculated phonon dispersion. In the pressure domain of interest, the phonon dispersions of bcc Th4H15 and bct ThH2 are positive, indicating the dynamical stability of these two phases, while the fcc ThH2 is unstable. The thermodynamic properties including the lattice vibration energy, entropy, and specific heat are predicted for these stable phases. The vibrational free energy decreases with the increase of the temperature, and the entropy and the heat capacity are proportional to the temperature and inversely proportional to the pressure. As the pressure increases, the resistance to the external pressure is strengthened for Th4H15 and ThH2. Project supported by the Long-Term Subsidy Mechanism from the Ministry of Finance and the Ministry of Education of China.
Constant-Pressure Hydraulic Pump
NASA Technical Reports Server (NTRS)
Galloway, C. W.
1982-01-01
Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.
Stankovicha, Joseph J; Gritti, Fabrice; Beaver, Lois Ann; Stevensona, Paul G; Guiochon, Georges
2013-11-29
Five methods were used to implement fast gradient separations: constant flow rate, constant column-wall temperature, constant inlet pressure at moderate and high pressures (controlled by a pressure controller),and programmed flow constant pressure. For programmed flow constant pressure, the flow rates and gradient compositions are controlled using input into the method instead of the pressure controller. Minor fluctuations in the inlet pressure do not affect the mobile phase flow rate in programmed flow. There producibilities of the retention times, the response factors, and the eluted band width of six successive separations of the same sample (9 components) were measured with different equilibration times between 0 and 15 min. The influence of the length of the equilibration time on these reproducibilities is discussed. The results show that the average column temperature may increase from one separation to the next and that this contributes to fluctuation of the results.
Changes in ionic selectivity with changes in density of water in gels and cells
Wiggins, Philippa M.; van Ryn, René T.
1990-01-01
Gels equilibrated with aqueous solutions of impermeant solutes reached a steady state in which, in the absence of a pressure difference, the activity of water in the pores of the gel was higher than that of water in the external solution. The chemical potential of water in the gel/polymer solution slurry was higher than that in the supernatant polymer solution removed from the gel. Water in the pores of the gel decreased in density to 0.96 as increasing osmotic stress was applied. It is argued that at constant temperature and pressure water can equilibrate between two compartments of unequal osmolality only by adjusting its molar volume. Experiments showed that when gel water had a higher activity than external water it was K+ selective; when it had a lower activity it was Na+ selective. It is proposed that a continuous spectrum of water structures can exist in these two compartment systems from dense, reactive, weakly-bonded water which selects highly hydrated ions, to expanded, stretched, unreactive, viscous water which is strongly hydrogen bonded and selects K+ and univalent anions. These findings are related to the state and properties of cytoplasmic water which is probably held under osmotic stress by the activity of the sodium pump. PMID:19431765
Merging Hyperspectural Imagery and Multi Scale Modeling for Laser Lethality
2016-02-24
standing aluminum films, (2) the effect of the external gas pressure on the flow structures and the mechanisms of the alumina and oxygen transport to...expansion from Al target irradiated by a continuous wave laser into a supersonic external air flow is investigated in kinetic simulations performed for...a broad range of pressure in the external flow. The results of the simulations reveal a significant effect of the external gas pressure on the flow
Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois Ann; Guiochon, Georges
2014-01-10
Using a column packed with fully porous particles, four methods for controlling the flow rates at which gradient elution runs are conducted in very high pressure liquid chromatography (VHPLC) were tested to determine whether reproducible thermal conditions could be achieved, such that subsequent analyses would proceed at nearly the same initial temperature. In VHPLC high flow rates are achieved, producing fast analyses but requiring high inlet pressures. The combination of high flow rates and high inlet pressures generates local heat, leading to temperature changes in the column. Usually in this case a post-run time is input into the analytical method to allow the return of the column temperature to its initial state. An alternative strategy involves operating the column without a post-run equilibration period and maintaining constant temperature variations for subsequent analysis after conducting one or a few separations to bring the column to a reproducible starting temperature. A liquid chromatography instrument equipped with a pressure controller was used to perform constant pressure and constant flow rate VHPLC separations. Six replicate gradient separations of a nine component mixture consisting of acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide dissolved in water/acetonitrile (65:35, v/v) were performed under various experimental conditions: constant flow rate, two sets of constant pressure, and constant pressure operation with a programmed flow rate. The relative standard deviations of the response factors for all the analytes are lower than 5% across the methods. Programming the flow rate to maintain a fairly constant pressure instead of using instrument controlled constant pressure improves the reproducibility of the retention times by a factor of 5, when plotting the chromatograms in time. Copyright © 2013 Elsevier B.V. All rights reserved.
Keefe, Douglas H; Feeney, M Patrick; Hunter, Lisa L; Fitzpatrick, Denis F
2017-01-01
Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz.
Liu, Yong; Lin, Zhongguo
2014-04-01
The present study employed a quantitative survey to ascertain whether the external pressure of environmental risk management (ERM) on commercial banks was a contributing factor to their ERM behavior. Data was obtained using questionnaires from 204 branches of commercial banks located in the Yangtze River Delta of China. The relationship between external pressure and behavior was tested using a linear structural relations model through path analysis. The results revealed that external pressure of ERM was significantly and positively related to the behavior and that pressure from governmental regulations was the most important contributing factor in the passive feedback behavior and preventive behavior of commercial banks. The pressure from markets was the most important contributing factor in banks' active participation behavior; the pressure from community and NGOs was the most important contributing factor in their enthusiastic behavior.
NASA Technical Reports Server (NTRS)
Simoneau, R. J.
1975-01-01
Choked flow rates and axial pressure distributions were measured for subcooled nitrogen in a converging-diverging nozzle with a constant area section in the throat region. Stagnation pressures ranged from slightly above saturation to twice the thermodynamic critical pressure. Stagnation temperatures ranged from 0.75 to 1.03 times the thermodynamic critical temperature. The choking plane is at the divergence end of the constant area throat section. At high stagnation pressures the fluid stays liquid well into the constant area throat region; at near saturation stagnation pressures it appears that vaporization occurs at or before the entrance to the constant area throat region. The throat-to-stagnation pressure ratio data exhibits an anomalous flat region, and this anomaly is related to the two-phase process. The fluid is metastably all liquid below the saturation pressure.
Competition of superconductivity with the structural transition in M o 3 S b 7
Ye, G. Z.; Cheng, J. -G.; Yan, Jiaqiang; ...
2016-12-14
Prior to the superconducting transition at T c ≈ 2.3 K, Mo 3Sb 7 undergoes a symmetry-lowering, cubic-to-tetragonal structural transition at T s = 53 K. In this paper, we have monitored the pressure dependence of these two transitions by measuring the resistivity of Mo 3Sb 7 single crystals under various hydrostatic pressures up to 15 GPa. The application of external pressure enhances T c but suppresses T s until P c ≈ 10 GPa, above which a pressure-induced first order structural transition takes place and is manifested by the phase coexistence in the pressure range 8 ≤ P ≤more » 12 GPa. The cubic phase above 12 GPa is also found to be superconducting with a higher T c ≈ 6 K that decreases slightly with further increasing pressure. The variations with pressure of T c and T s satisfy the Bilbro-McMillan equation, i.e. T c nT s 1-n = constant, thus suggesting the competition of superconductivity with the structural transition that has been proposed to be accompanied with a spin-gap formation at T s. Finally, this scenario is supported by our first-principles calculations which imply the plausible importance of magnetism that competes with the superconductivity in Mo 3Sb 7.« less
NASA Astrophysics Data System (ADS)
Ustinov, E. A.
2017-07-01
The aim of this paper is to present a method of a direct evaluation of the chemical potential of fluid, liquid, and solid with kinetic Monte Carlo simulation. The method is illustrated with the 12-6 Lennard-Jones (LJ) system over a wide range of density and temperature. A distinctive feature of the methodology used in the present study is imposing an external potential on the elongated simulation box to split the system into two equilibrium phases, one of which is substantially diluted. This technique provides a reliable direct evaluation of the chemical potential of the whole non-uniform system (including that of the uniformly distributed dense phase in the central zone of the box), which, for example, is impossible in simulation of the uniform crystalline phase. The parameters of the vapor-liquid, liquid-solid, and fluid-solid transitions have been reliably determined. The chemical potential and the pressure are defined as thermodynamically consistent functions of density and temperature separately for the liquid and the solid (FCC) phases. It has been shown that in two-phase systems separated by a flat interface, the crystal melting always occurs at equilibrium conditions. It is also proved that in the limit of zero temperature, the specific heat capacity of an LJ crystal at constant volume is exactly 3Rg (where Rg is the gas constant) without resorting to harmonic oscillators.
Weber, J A; Tenhunen, J D; Lange, O L
1985-09-01
The effect of temperature on photosynthesis at constant water-vapor pressure in the air was investigated using two sclerophyll species, Arbutus unedo and Quercus suber, and one mesophytic species, Spinacia oleracea. Photosynthesis and transpiration were measured over a range of temperatures, 20-39° C. The external concentration of CO2 was varied from 340 μbar to near CO2 compensation. The initial slope (carboxylation efficiency, CE) of the photosynthetic response to intercellular CO2 concentration, the CO2 compensation point (Γ), and the extrapolated rate of CO2 released into CO2-free air (R i) were calculated. At an external CO2 concentration of 320-340 μbar CO2, photosynthesis decreased with temperature in all species. The effect of temperature on Γ was similar in all species. While CE in S. oleracea changed little with temperature, CE decreased by 50% in Q. suber as temperature increased from 25 to 34° C. Arbutus unedo also exhibited a decrease in CE at higher temperatures but not as marked as Q. suber. The absolut value of R i increased with temperature in S. oleracea, while changing little or decreasing in the sclerophylls. Variations in Γ and R i of the sclerophyll species are not consistent with greater increase of respiration with temperature in the light in these species compared with S. oleracea.
NASA Astrophysics Data System (ADS)
Xu, Xiaobin; Liu, Yangqian; Gao, Fuyu; Song, Ningfang
2018-07-01
Hollow-core photonic bandgap fibers (HC-PBFs) are suitable for spaceborne fiber optical gyroscopes owing to their excellent environmental adaptability. However, hundreds of small holes full of air at one atmosphere of pressure can make the HC-PBF sensitive to external atmospheric pressure. In this study, we investigated the phase sensitivity of the fundamental mode to external atmospheric pressure for the HC-PBF, and the experimental result indicates that the phase sensitivity is approximately 1.6 × 10-5 ppm/Pa, which is mostly contributed by the change in the pressure-induced length. Through the choice of coating, the phase sensitivity to external atmospheric pressure can be reduced by about a factor of five compared to current HC-PBFs, and the excellent temperature performance can be maintained at the same time.
ERIC Educational Resources Information Center
Musambira, George; Collins, Steven; Brown, Tim; Voss, Kimberly
2012-01-01
Although communication program faculty have traditionally not enjoyed large grants for research, administrators are pressuring them to garner external funding. This article examines the success rate of securing external funding that communication administrators reported for their units. Results show that while the pressure has increased on most…
Chemical potential in active systems: predicting phase equilibrium from bulk equations of state?
NASA Astrophysics Data System (ADS)
Paliwal, Siddharth; Rodenburg, Jeroen; van Roij, René; Dijkstra, Marjolein
2018-01-01
We derive a microscopic expression for a quantity μ that plays the role of chemical potential of active Brownian particles (ABPs) in a steady state in the absence of vortices. We show that μ consists of (i) an intrinsic chemical potential similar to passive systems, which depends on density and self-propulsion speed, but not on the external potential, (ii) the external potential, and (iii) a newly derived one-body swim potential due to the activity of the particles. Our simulations on ABPs show good agreement with our Fokker-Planck calculations, and confirm that μ (z) is spatially constant for several inhomogeneous active fluids in their steady states in a planar geometry. Finally, we show that phase coexistence of ABPs with a planar interface satisfies not only mechanical but also diffusive equilibrium. The coexistence can be well-described by equating the bulk chemical potential and bulk pressure obtained from bulk simulations for systems with low activity but requires explicit evaluation of the interfacial contributions at high activity.
Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom
2005-08-01
Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.
Ring stability of underground toroidal tanks
NASA Astrophysics Data System (ADS)
Lubis, Asnawi; Su'udi, Ahmad
2017-06-01
The design of pressure vessels subjected to internal pressure is governed by its strength, while the design of pressure vessels subjected to external pressure is governed by its stability, which is for circular cross-section is called the ring stability. This paper presented the results of finite element study of ring stability of circular toroidal tank without stiffener under external pressure. The tank was placed underground and external pressure load from soil was simulated as pressure at the top of the vessel along 30° circumferentially. One might ask the reason for choosing toroidal rather than cylindrical tank. Preliminary finite element studies showed that toroidal shells can withstand higher external pressure than cylindrical shells. In this study, the volume of the tank was fixed for 15,000 litters. The buckling external pressure (pL) was calculated for radius ratio (R/r) of 2, 3, and 4. The corresponding cross-section radiuses were 724.3 mm, 632.7 mm, and 574.9 mm, respectively. The selected element type was SHELL 281 from the ANSYS element library. To obtain the buckling load, the arc-length method was used in the nonlinear analysis. Both material and geometric nonlinearities were activated during the analysis. The conclusion of this study is that short-radius and thin-walled toroidal shell produces higher buckling load.
NASA Technical Reports Server (NTRS)
Demarest, H. H., Jr.
1972-01-01
The elastic constants and the entire frequency spectrum were calculated up to high pressure for the alkali halides in the NaCl lattice, based on an assumed functional form of the inter-atomic potential. The quasiharmonic approximation is used to calculate the vibrational contribution to the pressure and the elastic constants at arbitrary temperature. By explicitly accounting for the effect of thermal and zero point motion, the adjustable parameters in the potential are determined to a high degree of accuracy from the elastic constants and their pressure derivatives measured at zero pressure. The calculated Gruneisen parameter, the elastic constants and their pressure derivatives are in good agreement with experimental results up to about 600 K. The model predicts that for some alkali halides the Grunesen parameter may decrease monotonically with pressure, while for others it may increase with pressure, after an initial decrease.
Analytical vacuum force, atmospheric pressure dispute
NASA Astrophysics Data System (ADS)
Yongquan, Han
Typically, the gap gas molecules is 10-9 m, since the center speed of the tornado is over 100 m / sec, it divided by the speed of a tornado, the gap of the gas molecules becomes 10-11m. Equivalent to the gap when there is no tornado that the gas molecules allow radiation to pass through, equivalent to the gap is reduced gas molecules 100 times by a tornado. There is no change in the Earth's radiate, the Earth's radiation is reduced to one percent of the original intensity by the radiation through the tornado periphery into the center of the tornado. According to the APS Division of Nuclear Physics in APS -2013 Fall Meeting - Event - Gravitational radiation theory http://meetings.aps.org/Meeting/DNP13/Session/FB.8, which I published, the gravity will br reduced to the original gravity percentage one. Waterspout by the Earth's gravity to become the original one percent. Cause the external of the tornadoes atmospheric pressure is constant, the height waterspout should support column height atmospheric pressure is 100 times,that height waterspout may reach nearly kilometers.
Feasibility study of an active soft catheter actuated by SMA wires
NASA Astrophysics Data System (ADS)
Konh, Bardia; Karimi, Saeed; Miller, Scott
2018-03-01
This study aims to assess the feasibility of using a combination of thin elastomer tubes and SMA wires to develop an active catheter. Cardiac catheters have been widely used in investigational and interventional procedures such as angiography, angioplasty, electro- physiology, and endocardial ablation. The commercial models manually steer inside the patient's body via internally installed pull wires. Active catheters, on the other hand, have the potential to revolutionize surgical procedures because of their computer-controlled and enhanced motion. Shape memory alloys have been used for almost a decade as a trustworthy actuator for biomedical applications. In this work, SMA wires were attached to a small pressurized elastomer tube to realize deflection. The tube was pressurized to maintain a constant stress on the SMA wires. The tip motion via actuation of SMA wires was then measured and reported. The results of this study showed that by adopting an appropriate training process for the SMA wires prior to performing the experiments and adopting an appropriate internal pressure for the elastomer tube, less external loads on SMA wires would be needed for a consistent actuation.
Feasibility of nitric oxide administration by neonatal helmet-CPAP: a bench study.
Trevisanuto, Daniele; Doglioni, Nicoletta; Micaglio, Massimo; Zanardo, Vincenzo
2007-09-01
Inhaled nitric oxide (NO) may have a role in the treatment of preterm infants with respiratory failure. We evaluated the feasibility of administering NO therapy by a new continuous positive airway pressure (CPAP) system (neonatal helmet-CPAP). While maintaining a constant total flow of 8, 10, and 12 l.min(-1), NO concentrations were progressively increased to 5, 10, 20, and 40 p.p.m. in the neonatal helmet-CPAP pressure chamber (5 cmH2O). NO, NO2, and O2 concentrations were measured in the pressure chamber and the immediate external environment. In the chamber, NO2 levels remained low (
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monteseguro, V.; Rodríguez-Hernández, P.; Muñoz, A., E-mail: amunoz@ull.es
The structural, elastic, and vibrational properties of yttrium aluminum garnet Y{sub 3}Al{sub 5}O{sub 12} are studied under high pressure by ab initio calculations in the framework of the density functional theory. The calculated ground state properties are in good agreement with the available experimental data. Pressure dependences of bond length and bulk moduli of the constituent polyhedra are reported. The evolution of the elastic constants and the major elastic properties, Young and shear modulus, Poisson's ratios, and Zener anisotropy ratio, are described. The mechanical stability is analyzed, on the light of “Born generalized stability criteria,” showing that the garnet ismore » mechanically unstable above 116 GPa. Symmetries, frequencies, and pressure coefficients of the Raman-active modes are discussed on the basis of the calculated total and partial phonon density of states, which reflect the dynamical contribution of each atom. The relations between the phonon modes of Y{sub 3}Al{sub 5}O{sub 12} and the internal and external molecular modes of the different polyhedra are discussed. Infrared-active modes, as well as the silent modes, and their pressure dependence are also investigated. No dynamical instabilities were found below 116 GPa.« less
Keefe, Douglas H.; Feeney, M. Patrick; Hunter, Lisa L.; Fitzpatrick, Denis F.
2017-01-01
Human ear-canal properties of transient acoustic stimuli are contrasted that utilize measured ear-canal pressures in conjunction with measured acoustic pressure reflectance and admittance. These data are referenced to the tip of a probe snugly inserted into the ear canal. Promising procedures to calibrate across frequency include stimuli with controlled levels of incident pressure magnitude, absorbed sound power, and forward pressure magnitude. An equivalent pressure at the eardrum is calculated from these measured data using a transmission-line model of ear-canal acoustics parameterized by acoustically estimated ear-canal area at the probe tip and length between the probe tip and eardrum. Chirp stimuli with constant incident pressure magnitude and constant absorbed sound power across frequency were generated to elicit transient-evoked otoacoustic emissions (TEOAEs), which were measured in normal-hearing adult ears from 0.7 to 8 kHz. TEOAE stimuli had similar peak-to-peak equivalent sound pressure levels across calibration conditions. Frequency-domain TEOAEs were compared using signal level, signal-to-noise ratio (SNR), coherence synchrony modulus (CSM), group delay, and group spread. Time-domain TEOAEs were compared using SNR, CSM, instantaneous frequency and instantaneous bandwidth. Stimuli with constant incident pressure magnitude or constant absorbed sound power across frequency produce generally similar TEOAEs up to 8 kHz. PMID:28147608
Transition to a Source with Modified Physical Parameters by Energy Supply or Using an External Force
NASA Astrophysics Data System (ADS)
Kucherov, A. N.
2017-11-01
A study has been made of the possibility for the physical parameters of a source/sink, i.e., for the enthalpy, temperature, total pressure, maximum velocity, and minimum dimension, at a constant radial Mach number to be changed by energy or force action on the gas in a bounded zone. It has been shown that the parameters can be controlled at a subsonic, supersonic, and transonic (sonic in the limit) radial Mach number. In the updated source/sink, all versions of a vortex-source combination can be implemented: into a vacuum, out of a vacuum, into a submerged space, and out of a submerged space, partially or fully.
Vertical normal modes of a mesoscale model using a scaled height coordinate
NASA Technical Reports Server (NTRS)
Lipton, A. E.; Pielke, R. A.
1986-01-01
Vertical modes were derived for a version of the Colorado State Regional Atmospheric Mesoscale Modeling System. The impacts of three options for dealing with the upper boundary of the model were studied. The standard model formulation holds pressure constant at a fixed altitude near the model top, and produces a fastest mode with a speed of about 90 m/sec. An alternative formulation, which allows for an external mode, could require recomputation of vertical modes for every surface elevation on the horizontal grid unless the modes are derived in a particular way. These results have bearing on the feasibility of applying vertical mode initialization to models with scaled height coordinates.
Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.
Mannino, Brian J; Pullen, Michael W; Gaines, Robert
2017-03-01
Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.
Diastolic function of the nonfilling human left ventricle.
Paulus, W J; Vantrimpont, P J; Rousseau, M F
1992-12-01
To investigate an early-diastolic left ventricular suction effect in humans, tip-micromanometer left ventricular pressure recordings were obtained in patients with mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon, which fits tightly in the mitral orifice. When mitral inflow was impeded in anesthetized dogs, left ventricular pressure decayed to a negative asymptote value. This negative asymptote value was consistent with an early diastolic suction effect. Tip-micromanometer left ventricular pressure recordings were obtained in 23 patients with symptomatic mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon. The left ventricular diastolic asymptote pressure (P(asy)) was determined in 47 nonfilling beats with a sufficiently long (greater than 200 ms) diastolic time interval (that is, the interval from minimal first derivative of left ventricular pressure to left ventricular end-diastolic pressure) and equaled 2 +/- 3 mm Hg for beats with normal intraventricular conduction and 3 +/- 2 mm Hg for beats with aberrant intraventricular conduction. Left ventricular angiography was performed in five patients during the first inflation of the Inoue balloon at the time of complete balloon expansion. Left ventricular end-diastolic volume of the nonfilling beats averaged 38 +/- 14 ml and was comparable to the left ventricular end-systolic volume (39 +/- 19 ml) measured during baseline angiography before mitral valvuloplasty. Time constants of left ventricular pressure decay were calculated on 21 nonfilling beats with a diastolic time interval greater than 200 ms, normal intraventricular conduction and peak left ventricular pressure greater than 50 mm Hg. Time constants (T0 and TBF) derived from an exponential curve fit with zero asymptote pressure and with a best-fit asymptote pressure were compared with a time constant (T(asy)) derived from an exponential curve fit with the measured diastolic left ventricular asymptote pressure. The value for T(asy) (37 +/- 9 ms) was significantly smaller than that for TBF (68 +/- 28 ms, p less than 0.001) and the value for the measured diastolic left ventricular asymptote pressure (2 +/- 4 mm Hg) was significantly larger than that for the best-fit asymptote pressure (-9 +/- 11 mm Hg, p less than 0.001). T0 (44 +/- 20 ms) was significantly (p less than 0.01) different from TBF but not from T(asy). During balloon inflation of a self-positioning Inoue balloon, left ventricular pressure decayed continuously toward a positive asymptote value and left ventricular cavity volume was comparable to the left ventricular end-systolic volume of filling beats. In these nonfilling beats, the best-fit asymptote pressure was unrelated to the measured asymptote pressure and T0 was a better measure of T(asy) than was TBF. Reduced internal myocardial restoring forces, caused by different extracellular matrix of the human heart, reduced external myocardial restoring forces caused by low coronary perfusion pressure during the balloon inflation and inward motion of the balloon-occluded mitral valve into the left ventricular cavity could explain the failure to observe significant diastolic left ventricular suction in the human heart.
Šesták, Jozef; Kahle, Vladislav
2014-07-11
Performing gradient liquid chromatography at constant pressure instead of constant flow rate has serious potential for shortening the analysis time and increasing the productivity of HPLC instruments that use gradient methods. However, in the constant pressure mode the decreasing column permeability during a long period of time negatively affects the repeatability of retention time. Thus a volume-based approach, in which the detector signal is plotted as a function of retention volume, must be taken into consideration. Traditional HPLC equipment, however, requires quite complex hardware and software modifications in order to work at constant pressure and in the volume-based mode. In this short communication, a low cost and easily feasible pressure-controlled extension of the previously described simple gradient liquid chromatography platform is proposed. A test mixture of four nitro esters was separated by 10-60% (v/v) acetone/water gradient and a high repeatability of retention volumes at 20MPa (RSD less than 0.45%) was realized. Separations were also performed at different values of pressure (20, 25, and 31MPa), and only small variations of the retention volumes (up to 0.8%) were observed. In this particular case, the gain in the analysis speed of 7% compared to the constant flow mode was realized at a constant pressure. Copyright © 2014 Elsevier B.V. All rights reserved.
Nonlinear vibration of a hemispherical dome under external water pressure
NASA Astrophysics Data System (ADS)
Ross, C. T. F.; McLennan, A.; Little, A. P. F.
2011-07-01
The aim of this study was to analyse the behaviour of a hemi-spherical dome when vibrated under external water pressure, using the commercial computer package ANSYS 11.0. In order to achieve this aim, the dome was modelled and vibrated in air and then in water, before finally being vibrated under external water pressure. The results collected during each of the analyses were compared to the previous studies, and this demonstrated that ANSYS was a suitable program and produced accurate results for this type of analysis, together with excellent graphical displays. The analysis under external water pressure, clearly demonstrated that as external water pressure was increased, the resonant frequencies decreased and a type of dynamic buckling became likely; because the static buckling eigenmode was similar to the vibration eigenmode. ANSYS compared favourably with the in-house software, but had the advantage that it produced graphical displays. This also led to the identification of previously undetected meridional modes of vibration; which were not detected with the in-house software.
NASA Technical Reports Server (NTRS)
Sorensen, E
1940-01-01
The conventional axial blowers operate on the high-pressure principle. One drawback of this type of blower is the relatively low pressure head, which one attempts to overcome with axial blowers producing very high pressure at a given circumferential speed. The Schicht constant-pressure blower affords pressure ratios considerably higher than those of axial blowers of conventional design with approximately the same efficiency.
NASA Astrophysics Data System (ADS)
Got, J. L.; Amitrano, D.; Carrier, A.; Marsan, D.; Jouanne, F.; Vogfjord, K. S.
2017-12-01
At Grimsvötn volcano, high-quality earthquake and continuous GPS data were recorded by the Icelandic Meteorological Office during its 2004-2011 inter-eruptive period and exhibited remarkable patterns : acceleration of the cumulated earthquake number, and a 2-year exponential decrease in displacement rate followed by a 4-year constant inflation rate. We proposed a model with one magma reservoir in a non-linear elastic damaging edifice, with incompressible magma and a constant pressure at the base of the magma conduit. We first modelled seismicity rate and damage as a function of time, and show that Kachanov's elastic brittle damage law may be used to express the decrease of the effective shear modulus with time. We then derived simple analytical expressions for the magma reservoir overpressure and the surface displacement as a function of time. We got a very good fit of the seismicity and surface displacement data by adjusting only three phenomenological parameters and computed magma reservoir overpressure, magma flow and strain power as a function of time. Overpressure decrease is controlled by damage and shear modulus decrease. Displacement increases, although overpressure is decreasing, because shear modulus decreases more than overpressure. Normalized strain power reaches a maximum 0.25 value. This maximum is a physical limit, after which the elasticity laws are no longer valid, earthquakes cluster, cumulative number of earthquakes departs from the model. State variable extrema provide four reference times that may be used to assess the mechanical state and dynamics of the volcanic edifice. We also performed the spatial modelling of the progressive damage and strain localization around a pressurized magma reservoir. We used Kachanov's damage law and finite element modelling of an initially elastic volcanic edifice pressurized by a spherical magma reservoir, with a constant pressure in the reservoir and various external boundary conditions. At each node of the model, Young's modulus is decreased if deviatoric stress locally reaches the Mohr-Coulomb plastic threshold. For a compressive horizontal stress, the result shows a complex strain localization pattern, showing reverse and normal faulting very similar to what is obtained from analog modelling and observed at volcanic resurgent domes.
Diffusional falsification of kinetic constants on Lineweaver-Burk plots.
Ghim, Y S; Chang, H N
1983-11-07
The effect of mass transfer resistances on the Lineweaver-Burk plots in immobilized enzyme systems has been investigated numerically and with analytical approximate solutions. While Hamilton, Gardner & Colton (1974) studied the effect of internal diffusion resistances in planar geometry, our study was extended to the combined effect of internal and external diffusion in cylindrical and spherical geometries as well. The variation of Lineweaver-Burk plots with respect to the geometries was minimized by modifying the Thiele modulus and the Biot number with the shape factor. Especially for a small Biot number all the three Lineweaver-Burk plots fell on a single line. As was discussed by Hamilton et al. (1974), the curvature of the line for large external diffusion resistances was small enough to be assumed linear, which was confirmed from the two approximate solutions for large and small substrate concentrations. Two methods for obtaining intrinsic kinetic constants were proposed: First, we obtained both maximum reaction rate and Michaelis constant by fitting experimental data to a straight line where external diffusion resistance was relatively large, and second, we obtained Michaelis constant from apparent Michaelis constant from the figure in case we knew maximum reaction rate a priori.
NASA Technical Reports Server (NTRS)
Montoya, L. C.; Lux, D. P.
1975-01-01
Wing pressure distributions obtained in flight with flush orifice and external tubing orifice installations for Mach numbers from 0.50 to 0.97 are compared. The procedure used to install the external tubing orifice is discussed. The results indicate that external tubing orifice installations can give useful results.
Appalakondaiah, S; Vaitheeswaran, G; Lebègue, S
2013-05-14
We report a detailed theoretical study of the structural and vibrational properties of solid nitromethane using first principles density functional calculations. The ground state properties were calculated using a plane wave pseudopotential code with either the local density approximation, the generalized gradient approximation, or with a correction to include van der Waals interactions. Our calculated equilibrium lattice parameters and volume using a dispersion correction are found to be in reasonable agreement with the experimental results. Also, our calculations reproduce the experimental trends in the structural properties at high pressure. We found a discontinuity in the bond length, bond angles, and also a weakening of hydrogen bond strength in the pressure range from 10 to 12 GPa, picturing the structural transition from phase I to phase II. Moreover, we predict the elastic constants of solid nitromethane and find that the corresponding bulk modulus is in good agreement with experiments. The calculated elastic constants show an order of C11> C22 > C33, indicating that the material is more compressible along the c-axis. We also calculated the zone center vibrational frequencies and discuss the internal and external modes of this material under pressure. From this, we found the softening of lattice modes around 8-11 GPa. We have also attempted the quasiparticle band structure of solid nitromethane with the G0W0 approximation and found that nitromethane is an indirect band gap insulator with a value of the band gap of about 7.8 eV with G0W0 approximation. Finally, the optical properties of this material, namely the absorptive and dispersive part of the dielectric function, and the refractive index and absorption spectra are calculated and the contribution of different transition peaks of the absorption spectra are analyzed. The static dielectric constant and refractive indices along the three inequivalent crystallographic directions indicate that this material has a considerable optical anisotropy.
Mei, Ling; Jiao, Hongmei; Sharma, Tarun; Dua, Arshish; Sanvanson, Patrick; Jadcherla, Sudarshan R; Shaker, Reza
2017-11-01
External cricoid pressure is increasingly used to augment the upper esophageal sphincter (UES). Our objective was to determine the effect of 1) pressures applied to cricoid, supracricoid, and subcricoid regions on the length and amplitude of the UES high-pressure zone (UESHPZ), and 2) the external cricoid pressure on lower esophageal sphincter (LES) tone. Case-control study. We studied 11 patients with supraesophageal reflux (mean age 58 ± 12 years) and 10 healthy volunteers (mean age 47 ± 19 years). We tested 20, 30, and 40 mm Hg pressures to cricoid, 1 cm proximal and 1 cm distal to the cricoid. In an additional 15 healthy volunteers (mean age 46 ± 23 years), we studied the effect of external cricoid pressure on LES tone. UES and LES pressures were determined using high-resolution manometry. There was significant increase of UESHPZ length with application of pressure at all sites. The increase of UESHPZ length was relatively symmetric, more orad, and more caudad when the pressure was applied at the cricoid, supracricoid, and subcricoid levels, respectively. The magnitude of pressure increase was greatest at the middle and orad part of the UESHPZ when the pressure was applied at the cricoid and supracricoid levels, respectively. The corresponding magnitude of increase in the caudad part of the UESHPZ was not observed with pressure at the subcricoid level. There was no change of the LES pressure with application of cricoid pressure. The effect of external pressure on the UESHPZ is site dependent. Subcricoid pressure has the least effect on UESHPZ. External cricoid pressure at 20 to 40 mm Hg has no effect on the LES pressure. 3b. Laryngoscope, 127:2466-2474, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Lee, Yonghun; Kim, Dong-Min; Li, Zhenglin; Kim, Dong-Eun; Kim, Sung-Jin
2018-03-13
We demonstrate a microfiltration chip that separates blood plasma by using water-head-driven pulsatile pressures rather than any external equipment and use it for on-chip amplification of nucleic acids. The chip generates pulsatile pressures to significantly reduce filter clogging without hemolysis, and consists of an oscillator, a plasma-extraction pump, and filter units. The oscillator autonomously converts constant water-head pressure to pulsatile pressure, and the pump uses the pulsatile pressure to extract plasma through the filter. Because the pulsatile pressure can periodically clear blood cells from the filter surface, filter clogging can be effectively reduced. In this way, we achieve plasma extraction with 100% purity and 90% plasma recovery at 15% hematocrit. During a 10 min period, the volume of plasma extracted was 43 μL out of a 243 μL extraction volume at 15% hematocrit. We also studied the influence of the pore size and diameter of the filter, blood loading volume, oscillation period, and hematocrit level on the filtration performance. To demonstrate the utility of our chip for point-of-care testing (POCT) applications, we successfully implemented on-chip amplification of a nucleic acid (miDNA21) in plasma filtered from blood. We expect our chip to be useful not only for POCT applications but also for other bench-top analysis tools using blood plasma.
Jiao, Hongmei; Mei, Ling; Sharma, Tarun; Kern, Mark; Sanvanson, Patrick
2016-01-01
Oropharyngeal dysphagia due to upper esophageal sphincter (UES) dysfunction is commonly encountered in the clinical setting. Selective experimental perturbation of various components of the deglutitive apparatus can provide an opportunity to improve our understanding of the swallowing physiology and pathophysiology. The aim is to characterize the pharyngeal and UES deglutitive pressure phenomena in an experimentally induced restriction of UES opening in humans. We studied 14 volunteers without any dysphagic symptoms (7 men, 66 ± 11 yr) but with various supraesophageal reflux symptoms. To induce UES restriction, we used a handmade device that with adjustment could selectively apply 0, 20, 30, or 40 mmHg pressure perpendicularly to the cricoid cartilage. Deglutitive pharyngeal and UES pressure phenomena were determined during dry and 5- and 10-ml water swallows × 3 for each of the UES perturbations. External cricoid pressure against the UES resulted in a significant increase in hypopharyngeal intrabolus pressure and UES nadir deglutitive relaxation pressure for all tested swallowed volumes (P < 0.05). Application of external cricoid pressure increased the length of the UES high pressure zone from 2.5 ± 0.2 to 3.1 ± 0.2, 3.5 ± 0.1, and 3.7 ± 0.1 cm for 20, 30, and 40 mmHg cricoid pressure, respectively (P < 0.05). External cricoid pressure had no significant effect on pharyngeal peristalsis. On the other hand, irrespective of external cricoid pressure deglutitive velopharyngeal contractile integral progressively increased with increased swallowed volumes (P < 0.05). In conclusion, acute experimental restriction of UES opening by external cricoid pressure manifests the pressure characteristics of increased resistance to UES transsphincteric flow observed clinically without affecting the pharyngeal peristaltic contractile function. PMID:27198193
The Gaseous Explosive Reaction : The Effect of Inert Gases
NASA Technical Reports Server (NTRS)
Stevens, F W
1928-01-01
Attention is called in this report to previous investigations of gaseous explosive reactions carried out under constant volume conditions, where the effect of inert gases on the thermodynamic equilibrium was determined. The advantage of constant pressure methods over those of constant volume as applied to studies of the gaseous explosive reaction is pointed out and the possibility of realizing for this purpose a constant pressure bomb mentioned. The application of constant pressure methods to the study of gaseous explosive reactions, made possible by the use of a constant pressure bomb, led to the discovery of an important kinetic relation connecting the rate of propagation of the zone of explosive reaction within the active gases, with the initial concentrations of those gases: s = K(sub 1)(A)(sup n1)(B)(sup n2)(C)(sup n3)------. By a method analogous to that followed in determining the effect of inert gases on the equilibrium constant K, the present paper records an attempt to determine their kinetic effect upon the expression given above.
Calculation of the external work done during walking in very young children.
Schepens, Benedicte; Detrembleur, Christine
2009-10-01
During walking, muscles must perform positive work to replace the energy lost from the body at each step, even if the average speed is constant and the terrain level. Young children have immature and irregular walk, but little is known about the effect of this walking pattern on the muscular external work done. Our objective was to measure using force platforms and the method of Cavagna (J Appl Physiol 39:174-179, 1975) the amount of muscular external work done by 1-year-old-, 4-year-old children and adults during walking. We were interested to quantify the approximation made by measuring only the positive external work done and assuming it reflects the external work done. After having confirmed that young children were not able to walk at a constant average speed over a complete number of steps, we showed the effect of the selection of trials by measuring the external work done assuming the amount of positive work done is equal to the negative work done (supposing there is no acceleration or deceleration over a complete number of steps). We observed that even if young subjects were not able to walk at a constant lateral speed over a complete number of steps, the amount of work done to maintain the center of mass movements in the transversal plane is not more than 10% of the external positive work done. This observational study points out that the measurement of external work, a good summary indicator for the gait mechanics, may be interpreted precociously when the population studied walked irregularly.
Measurement of Intrasound from the Marine Environment
2015-09-01
external inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure interference signal...moves up and down. An external inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure...10 EXTERNAL INTEGRATED MEASUREMENT UNIT ..................................................... 13 ADAPTIVE NOISE CANCELATION
External Pressure, Motivation, and Treatment Outcome among Pregnant Substance-Using Women
Ondersma, Steven J.; Winhusen, Theresa; Lewis, Daniel F.
2009-01-01
The weight of evidence suggests that legal pressure to enter treatment facilitates retention. However, the extent to which such mandates (a) influence actual levels of substance use, or (b) also facilitate retention among pregnant women, is unclear. Associations between external pressure—defined as self-reported pressure to attend treatment under threat of incarceration, loss of child custody, and/or loss of subsidized housing—and the key outcomes of retention and substance use were therefore examined in a sample of 200 pregnant women receiving community-based substance abuse treatment. The role of external pressure was examined in a series of Cox and GEE regressions, which suggested that external pressure as measured at baseline was associated with decreased risk of dropout (Hazard Ratio = .47, p = .001) and fewer drug-positive urine tests throughout treatment and 12-week follow-up (OR = 0.48, p = .03). These differences did not appear to be the result of baseline differences between coerced and non-coerced participants in education, legal history, presence or absence of a substance use disorder, employment, or motivation. The present findings extend the larger literature on external pressure by demonstrating effects on drug use as well as on retention, and among pregnant women. PMID:19926408
Buckling of Cracked Laminated Composite Cylindrical Shells Subjected to Combined Loading
NASA Astrophysics Data System (ADS)
Allahbakhsh, Hamidreza; Shariati, Mahmoud
2013-10-01
A series of finite element analysis on the cracked composite cylindrical shells under combined loading is carried out to study the effect of loading condition, crack size and orientation on the buckling behavior of laminated composite cylindrical shells. The interaction buckling curves of cracked laminated composite cylinders subject to different combinations of axial compression, bending, internal pressure and external pressure are obtained, using the finite element method. Results show that the internal pressure increases the critical buckling load of the CFRP cylindrical shells and bending and external pressure decrease it. Numerical analysis show that axial crack has the most detrimental effect on the buckling load of a cylindrical shell and results show that for lower values of the axial compressive load and higher values of the external pressure, the buckling is usually in the global mode and for higher values of axial compressive load and lower levels of external pressure the buckling mode is mostly in the local mode.
Determining Atmospheric Pressure Using a Water Barometer
ERIC Educational Resources Information Center
Lohrengel, C. Frederick, II; Larson, Paul R.
2012-01-01
The atmosphere is an envelope of compressible gases that surrounds Earth. Because of its compressibility and nonuniform heating by the Sun, it is in constant motion. The atmosphere exerts pressure on Earth's surface, but that pressure is in constant flux. This experiment allows students to directly measure atmospheric pressure by measuring the…
Application of Pressure Sensitive Paint to Confined Flow at Mach Number 2.5
NASA Technical Reports Server (NTRS)
Lepicovsky, J.; Bencic, T. J.; Bruckner, R. J.
1998-01-01
Pressure sensitive paint (PSP) is a novel technology that is being used frequently in external aerodynamics. For internal flows in narrow channels, and applications at elevated nonuniform temperatures, however, there are still unresolved problems that complicate the procedures for calibrating PSP signals. To address some of these problems, investigations were carried out in a narrow channel with supersonic flows of Mach 2.5. The first set of tests focused on the distribution of the wall pressure in the diverging section of the test channel downstream of the nozzle throat. The second set dealt with the distribution of wall static pressure due to the shock/wall interaction caused by a 25 deg. wedge in the constant Mach number part of the test section. In addition, the total temperature of the flow was varied to assess the effects of temperature on the PSP signal. Finally, contamination of the pressure field data, caused by internal reflection of the PSP signal in a narrow channel, was demonstrated. The local wall pressures were measured with static taps, and the wall pressure distributions were acquired by using PSP. The PSP results gave excellent qualitative impressions of the pressure field investigated. However, the quantitative results, specifically the accuracy of the PSP data in narrow channels, show that improvements need to be made in the calibration procedures, particularly for heated flows. In the cases investigated, the experimental error had a standard deviation of +/- 8.0% for the unheated flow, and +/- 16.0% for the heated flow, at an average pressure of 11 kpa.
Li, Lixiao; Kazoe, Yutaka; Mawatari, Kazuma; Sugii, Yasuhiko; Kitamori, Takehiko
2012-09-06
Understanding fluid and interfacial properties in extended nanospace (10-1000 nm) is important for recent advances of nanofluidics. We studied properties of water confined in fused-silica nanochannels of 50-1500 nm sizes with two types of cross-section: (1) square channel of nanoscale width and depth, and (2) plate channel of microscale width and nanoscale depth. Viscosity and wetting property were simultaneously measured from capillary filling controlled by megapascal external pressure. The viscosity increased in extended nanospace, while the wetting property was almost constant. Especially, water in the square nanochannels had much higher viscosity than the plate channel, which can be explained considering loosely coupled water molecules by hydrogen bond on the surface within 24 nm. This study suggests specificity of fluids two-dimensionally confined in extended nanoscale, in which the liquid is highly viscous by the specific water phase, while the wetting dynamics is governed by the well-known adsorbed water layer of several-molecules thickness.
Conner, Bradley T; Longshore, Douglas; Anglin, M Douglas
2009-04-01
Motivation for change has historically been viewed as the crucial element affecting responsiveness to drug treatment. Various external pressures, such as legal coercion, may engender motivation in an individual previously resistant to change. Dramatic relief may be the change process that is most salient as individuals internalize such external pressures. Results of structural equation modeling on data from 465 drug users (58.9% male; 21.3% Black, 34.2% Hispanic/Latino, and 35.1% White) entering drug treatment indicated that internal motivation and external pressure significantly and positively predicted dramatic relief and that dramatic relief significantly predicted attitudes towards drug treatment: chi (2) = 142.20, df = 100, p < 0.01; Robust Comparative Fit Index = 0.97, Root Mean Squared Error of Approximation = 0.03. These results indicate that when external pressure and internal motivation are high, dramatic relief is also likely to be high. When dramatic relief is high, attitudes towards drug treatment are likely to be positive. The findings indicate that interventions to get individuals into drug treatment should include processes that promote Dramatic Relief. Implications for addictions health services are discussed.
A novel scaling approach for sooting laminar coflow flames at elevated pressures
NASA Astrophysics Data System (ADS)
Abdelgadir, Ahmed; Steinmetz, Scott A.; Attili, Antonio; Bisetti, Fabrizio; Roberts, William L.
2016-11-01
Laminar coflow diffusion flames are often used to study soot formation at elevated pressures due to their well-characterized configuration. In these expriments, these flames are operated at constant mass flow rate (constant Reynolds number) at increasing pressures. Due to the effect of gravity, the flame shape changes and as a results, the mixing field changes, which in return has a great effect on soot formation. In this study, a novel scaling approach of the flame at different pressures is proposed. In this approach, both the Reynolds and Grashof's numbers are kept constant so that the effect of gravity is the same at all pressures. In order to keep the Grashof number constant, the diameter of the nozzle is modified as pressure varies. We report both numerical and experimental data proving that this approach guarantees the same nondimensional flow fields over a broad range of pressures. In the range of conditions studied, the Damkoehler number, which varies when both Reynolds and Grashof numbers are kept constant, is shown to play a minor role. Hence, a set of suitable flames for investigating soot formation at pressure is identified. This research made use of the resources of IT Research Computing at King Abdullah University of Science & Technology (KAUST), Saudi Arabia.
The molecular dynamics simulation on the mechanical properties of Ni glass with external pressure
NASA Astrophysics Data System (ADS)
Zhang, Chuan-Hui; Wang, Ying; Sun, Dong-Bai
2017-08-01
In this paper, rapid quenching of Ni from crystal to metallic glass (MG) at different external pressures is simulated by molecular dynamics. The pair distribution functions (PDFs), mean-square displacement, glass transition temperature (Tg) and elastic property are calculated and compared with each other. The split of the second PDF peak means the liquid’s transition to glass state starts as previously reported for other MGs. And the Ri/R1 ratio rule is found to hold very well in Ni MG and reveals the SPO structural feature in the configurations. Moreover, with high external pressure, Tg values are more approximated by density-temperature and enthalpy-temperature curves. At last, the elastic modulus and mechanics modulus of quenching models produced a monotonous effect with increasing external pressure and temperature.
Scheinpflug, L; Vorwerk, U; Begall, K
1995-01-01
By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.
1998-01-01
equipped with a constant- pressure switch or control: drills; tappers; fastener drivers; horizontal, vertical, and angle grinders with wheels more than...hand-held power tools must be equipped with either a positive “on-off” control switch, a constant pressure switch , or a “lock-on” control: disc sanders...percussion tools with no means of holding accessories securely, must be equipped with a constant- pressure switch that will shut off the power when the
NASA Technical Reports Server (NTRS)
Stevens, N. J.; Berkopec, F. D.; Blech, R. A.
1976-01-01
The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... window channels, aft cabin pressure web, external wing to fuselage fillets, and fasteners; repair or..., the vertical channels, the upper picture window channels, aft cabin pressure web, external wing to... lower wing main spar, the vertical channels, the upper picture window channels, aft cabin pressure web...
Air ejector augmented compressed air energy storage system
Ahrens, Frederick W.; Kartsounes, George T.
1980-01-01
Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.
Gorbacheva, E V; Ganchenko, G S; Demekhin, E A
2018-03-27
The stability of the electroosmotic flow of electrolyte-dielectric viscous liquids under the influence of the DC and AC electric fields along with the external pressure gradient is studied theoretically. Liquids are bounded by two infinite parallel plates. The lower wall bordering the electrolyte is assumed to be a charged surface, and the upper wall is electrically isolated. The charge at the lower boundary is assumed to be immobile, while the surface charge at the free surface is assumed to be mobile. In this paper, we study the micro- and nanosized liquid layers. The mathematical model is described by a nonlinear system of the Nernst-Planck-Poisson-Stokes partial differential equations with the appropriate boundary conditions on the solid surface, the electrolyte/dielectric interface, and on the upper wall. The pressure gradient is highly important for the stability of the flow. For the DC case, the external pressure could either stabilize and destabilize the flow depending on the relative directions of the electroosmotic flow and the pressure-driven flow. For the AC case, the dependence on the value of the external pressure is not monotonous for different wave numbers of perturbations, but, as a rule, the external pressure destabilizes the flow. As the frequency of the electric field increases, the one-dimensional solution of the problem becomes stable.
Effects of mucosal loading on vocal fold vibration.
Tao, Chao; Jiang, Jack J
2009-06-01
A chain model was proposed in this study to examine the effects of mucosal loading on vocal fold vibration. Mucosal loading was defined as the loading caused by the interaction between the vocal folds and the surrounding tissue. In the proposed model, the vocal folds and the surrounding tissue were represented by a series of oscillators connected by a coupling spring. The lumped masses, springs, and dampers of the oscillators modeled the tissue properties of mass, stiffness, and viscosity, respectively. The coupling spring exemplified the tissue interactions. By numerically solving this chain model, the effects of mucosal loading on the phonation threshold pressure, phonation instability pressure, and energy distribution in a voice production system were studied. It was found that when mucosal loading is small, phonation threshold pressure increases with the damping constant R(r), the mass constant R(m), and the coupling constant R(mu) of mucosal loading but decreases with the stiffness constant R(k). Phonation instability pressure is also related to mucosal loading. It was found that phonation instability pressure increases with the coupling constant R(mu) but decreases with the stiffness constant R(k) of mucosal loading. Therefore, it was concluded that mucosal loading directly affects voice production.
Effects of mucosal loading on vocal fold vibration
NASA Astrophysics Data System (ADS)
Tao, Chao; Jiang, Jack J.
2009-06-01
A chain model was proposed in this study to examine the effects of mucosal loading on vocal fold vibration. Mucosal loading was defined as the loading caused by the interaction between the vocal folds and the surrounding tissue. In the proposed model, the vocal folds and the surrounding tissue were represented by a series of oscillators connected by a coupling spring. The lumped masses, springs, and dampers of the oscillators modeled the tissue properties of mass, stiffness, and viscosity, respectively. The coupling spring exemplified the tissue interactions. By numerically solving this chain model, the effects of mucosal loading on the phonation threshold pressure, phonation instability pressure, and energy distribution in a voice production system were studied. It was found that when mucosal loading is small, phonation threshold pressure increases with the damping constant Rr, the mass constant Rm, and the coupling constant Rμ of mucosal loading but decreases with the stiffness constant Rk. Phonation instability pressure is also related to mucosal loading. It was found that phonation instability pressure increases with the coupling constant Rμ but decreases with the stiffness constant Rk of mucosal loading. Therefore, it was concluded that mucosal loading directly affects voice production.
75 FR 16655 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 700 Series Turbofan Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... pressure (HP-IP) turbine internal and external oil vent tubes for coking and carbon buildup, and cleaning... borescope inspections of the HP-IP turbine internal and external oil vent tubes for coking and carbon...-intermediate pressure (HP-IP) turbine internal oil vent tubes, external oil vent tubes, and bearing chamber...
Flow of High Internal Phase Ratio Emulsions through Pipes
NASA Astrophysics Data System (ADS)
Kostak, K.; Özsaygı, R.; Gündüz, I.; Yorgancıoǧlu, E.; Tekden, E.; Güzel, O.; Sadıklar, D.; Peker, S.; Helvacı, Ş. Ş.
2015-04-01
The flow behavior of W/O type of HIPRE stabilized by hydrogen bonds with a sugar (sorbitol) in the aqueous phase, was studied. Two groups of experiments were done in this work: The effect of wall shear stresses were investigated in flow through pipes of different diameters. For this end, HIPREs prestirred at constant rate for the same duration were used to obtain similar drop size distributions. Existence and extent of elongational viscosity were used as a probe to elucidate the effect of drop size distribution on the flow behavior: HIPREs prestirred for the same duration at different rates were subjected to flow through converging pipes. The experimental flow curves for flow through small cylindrical pipes indicated four different stages: 1) initial increase in the flow rate at low pressure difference, 2) subsequent decrease in the flow rate due to capillary flow, 3) pressure increase after reaching the minimum flow rate and 4) slip flow after a critical pressure difference. HIPREs with sufficient external liquid phase in the plateau borders can elongate during passage through converging pipes. In the absence of liquid stored in the plateau borders, the drops rupture during extension and slip flow takes place without elongation.
Demonstration that a new flow sensor can operate in the clinical range for cerebrospinal fluid flow
Raj, Rahul; Lakshmanan, Shanmugamurthy; Apigo, David; Kanwal, Alokik; Liu, Sheng; Russell, Thomas; Madsen, Joseph R.; Thomas, Gordon A.; Farrow, Reginald C.
2015-01-01
A flow sensor has been fabricated and tested that is capable of measuring the slow flow characteristic of the cerebrospinal fluid in the range from less than 4 mL/h to above 100 mL/h. This sensor is suitable for long-term implantation because it uses a wireless external spectrometer to measure passive subcutaneous components. The sensors are pressure-sensitive capacitors, in the range of 5 pF with an air gap at atmospheric pressure. Each capacitor is in series with an inductor to provide a resonant frequency that varies with flow rate. At constant flow, the system is steady with drift <0.3 mL/h over a month. At variable flow rate, V̇, the resonant frequency, f0, which is in the 200–400 MHz range, follows a second order polynomial with respect to V̇. For this sensor system the uncertainty in measuring f0 is 30 kHz which corresponds to a sensitivity in measuring flow of ΔV̇= 0.6 mL/hr. Pressures up to 20 cm H2O relative to ambient pressure were also measured. An implantable twin capacitor system is proposed that can measure flow, which is fully compensated for all hydrostatic pressures. For twin capacitors, other sources of systematic variation within clinical range, such as temperature and ambient pressure, are smaller than our sensitivity and we delineate a calibration method that should maintain clinically useful accuracy over long times. PMID:26543321
NASA Astrophysics Data System (ADS)
Peng, Z.; Day, D. A.; Stark, H.; Li, R.; Palm, B. B.; Brune, W. H.; Jimenez, J. L.
2015-04-01
Oxidation flow reactors (OFRs) using OH produced from low-pressure Hg lamps at 254 nm (OFR254) or both 185 and 254 nm (OFR185) are commonly used in atmospheric chemistry and other fields. OFR254 requires the addition of externally formed O3 since OH is formed from O3 photolysis, while OFR185 does not since O2 can be photolyzed to produce O3 and OH can also be formed from H2O photolysis. In this study, we use a plug-flow kinetic model to investigate OFR properties under a very wide range of conditions applicable to both field and laboratory studies. We show that the radical chemistry in OFRs can be characterized as a function of UV light intensity, H2O concentration, and total external OH reactivity (OHRext, e.g., from VOCs, NOx, and SO2). OH exposure is decreased by added external OH reactivity. OFR185 is especially sensitive to this effect at low UV intensity due to low primary OH production. OFR254 can be more resilient against OH suppression at high injected O3 (e.g., 70 ppm), as a larger primary OH source from O3, as well as enhanced recycling of HO2 to OH, make external perturbations to the radical chemistry less significant. However if the external OH reactivity in OFR254 is much larger than OH reactivity from injected O3, OH suppression can reach two orders of magnitude. For a typical input of 7 ppm O3 (OHRO3 = 10 s-1) ten-fold OH suppression is observed at OHRext ∼ 100 s-1, which is similar or lower than used in many laboratory studies. This finding may have important implications for the interpretation of past laboratory studies, as applying OHexp measurements acquired under different conditions could lead to over an order-of-magnitude error in the estimated OHexp. The uncertainties of key model outputs due to uncertainty in all rate constants and absorption cross-sections in the model are within ± 25% for OH exposure and within ± 60% for other parameters. These uncertainties are small relative to the dynamic range of outputs. Uncertainty analysis shows that most of the uncertainty is contributed by photolysis rates of O3, O2, and H2O and reactions of OH and HO2 with themselves or with some abundant species, i.e., O3 and H2O2. Using HOx-recycling vs. destructive external OH reactivity only leads to small changes in OHexp under most conditions. Changing the identity (rate constant) of external OH reactants can result in substantial changes in OHexp due to different reductions in OH suppression as the reactant is consumed. We also report two equations for estimating OH exposure in OFR254. We find that the equation estimating OHexp from measured O3 consumption performs better than an alternative equation that does not use it, and thus recommend measuring both input and output O3 concentrations in OFR254 experiments. This study contributes to establishing a firm and systematic understanding of the gas-phase HOx and Ox chemistry in these reactors, and enables better experiment planning and interpretation as well as improved design of future reactors.
NASA Technical Reports Server (NTRS)
Anderson, Karl F. (Inventor); Parker, Allen R., Jr. (Inventor)
1993-01-01
A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.
Longshore, Douglas; Anglin, M. Douglas
2009-01-01
Motivation for change has historically been viewed as the crucial element affecting responsiveness to drug treatment. Various external pressures, such as legal coercion, may engender motivation in an individual previously resistant to change. Dramatic relief may be the change process that is most salient as individuals internalize such external pressures. Results of structural equation modeling on data from 465 drug users (58.9% male; 21.3% Black, 34.2% Hispanic/Latino, and 35.1% White) entering drug treatment indicated that internal motivation and external pressure significantly and positively predicted dramatic relief and that dramatic relief significantly predicted attitudes towards drug treatment: χ2=142.20, df=100, p<0.01; Robust Comparative Fit Index=0.97, Root Mean Squared Error of Approximation=0.03. These results indicate that when external pressure and internal motivation are high, dramatic relief is also likely to be high. When dramatic relief is high, attitudes towards drug treatment are likely to be positive. The findings indicate that interventions to get individuals into drug treatment should include processes that promote Dramatic Relief. Implications for addictions health services are discussed. PMID:18535908
Verstraeten, M; Broeckhoven, K; Lynen, F; Choikhet, K; Landt, K; Dittmann, M; Witt, K; Sandra, P; Desmet, G
2013-01-25
The present contribution investigates the quantitation aspects of mass-sensitive detectors with nebulizing interface (ESI-MSD, ELSD, CAD) in the constant pressure gradient elution mode. In this operation mode, the pressure is controlled and maintained at a set value and the liquid flow rate will vary according to the inverse mobile phase viscosity. As the pressure is continuously kept at the allowable maximum during the entire gradient run, the average liquid flow rate is higher compared to that in the conventional constant flow rate operation mode, thus shortening the analysis time. The following three mass-sensitive detectors were investigated: mass spectrometry detector (MS), evaporative light scattering detector (ELSD) and charged aerosol detector (CAD) and a wide variety of samples (phenones, polyaromatic hydrocarbons, wine, cocoa butter) has been considered. It was found that the nebulizing efficiency of the LC-interfaces of the three detectors under consideration changes with the increasing liquid flow rate. For the MS, the increasing flow rate leads to a lower peak area whereas for the ELSD the peak area increases compared to the constant flow rate mode. The peak area obtained with a CAD is rather insensitive to the liquid flow rate. The reproducibility of the peak area remains similar in both modes, although variation in system permeability compromises the 'long-term' reproducibility. This problem can however be overcome by running a flow rate program with an optimized flow rate and composition profile obtained from the constant pressure mode. In this case, the quantification remains reproducibile, despite any occuring variations of the system permeability. Furthermore, the same fragmentation pattern (MS) has been found in the constant pressure mode compared to the customary constant flow rate mode. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Erum, Nazia; Azhar Iqbal, Muhammad
2017-09-01
The effect of pressure variation on stability, structural parameters, elastic constants, mechanical, electronic and thermodynamic properties of cubic SrKF3 fluoroperovskite have been investigated by using the full-potential linearized augmented plane wave (FP-LAPW) method combined with Quasi-harmonic Debye model in which the phonon effects are considered. The calculated lattice parameters show a prominent decrease in lattice constant and bonds length with the increase in pressure. The application of pressure from 0 to 25 GPa reveals a predominant characteristic associated with widening of bandgap with GGA and GGA plus Tran-Blaha modified Becke-Johnson (TB-mBJ) potential. The influence of pressure on elastic constants and their related mechanical parameters have been discussed in detail. Apart of linear dependence of elastic coefficients, transition from brittle to ductile behavior is also observed at elevated pressure ranges. We have successfully computed variation of lattice constant, volume expansion, bulk modulus, Debye temperature and specific heat capacities at pressure and temperature in the range of 0-25 GPa and 0-600 K.
Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra
2015-06-01
The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.
Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber
2011-12-01
Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.
Evolution of ferromagnetism in charge ordered manganite: An effect of external pressure
NASA Astrophysics Data System (ADS)
Dash, S.; Pradhan, M. K.; Rao, T. Lakshmana
2018-05-01
Detailed magnetic measurements of the Pr0.75Na0.25MnO3 polycrystalline sample have been carried out under external hydrostatic pressure upto 10kbar. Pressure strongly suppresses the first order magnetic transition, while thermal hysteresis narrows down progressively and then disappears with increase in pressure. The significant enhancement of the field cooled magnetization value at different pressures is due to the antiferromagnetic to ferromagnetic transformation, while ruling out any contribution from the domain alignment within the ferromagnetic phase.
Generalized Couette Poiseuille flow with boundary mass transfer
NASA Astrophysics Data System (ADS)
Marques, F.; Sanchez, J.; Weidman, P. D.
1998-11-01
A generalized similarity formulation extending the work of Terrill (1967) for Couette Poiseuille flow in the annulus between concentric cylinders of infinite extent is given. Boundary conditions compatible with the formulation allow a study of the effects of inner and outer cylinder transpiration, rotation, translation, stretching and twisting, in addition to that of an externally imposed constant axial pressure gradient. The problem is governed by [eta], the ratio of inner to outer radii, a Poiseuille number, and nine Reynolds numbers. Single-cylinder and planar problems can be recovered in the limits [eta][rightward arrow]0 and [eta][rightward arrow]1, respectively. Two coupled primary nonlinear equations govern the meridional motion generated by uniform mass flux through the porous walls and the azimuthal motion generated by torsional movement of the cylinders; subsidiary equations linearly slaved to the primary flow govern the effects of cylinder translation, cylinder rotation, and an external pressure gradient. Steady solutions of the primary equations for uniform source/sink flow of strength F through the inner cylinder are reported for 0[less-than-or-eq, slant][eta][less-than-or-eq, slant]1. Asymptotic results corroborating the numerical solutions are found in different limiting cases. For F<0 fluid emitted through the inner cylinder fills the gap and flows uniaxially down the annulus; an asymptotic analysis leads to a scaling that removes the effect of [eta] in the pressure parameter [beta], namely [beta]=[pi]2R*2, where R*=F(1[minus sign][eta])/(1+[eta]). The case of sink flow for F>0 is more complex in that unique solutions are found at low Reynolds numbers, a region of triple solutions exists at moderate Reynolds numbers, and a two-cell solution prevails at large Reynolds numbers. The subsidiary linear equations are solved at [eta]=0.5 to exhibit the effects of cylinder translation, rotation, and an axial pressure gradient on the source/sink flows.
ERIC Educational Resources Information Center
Schmidt-Rohr, Klaus
2014-01-01
We demonstrate that the formula for irreversible expansion work in most chemical thermodynamics textbooks does not apply during the expansion process. Instead of the "external pressure" P[subscript ext], the pressure P[subscript sys,mb] on the piston or other moving boundary (hence the subscript mb), which is nearly equal to the system…
Inducing Peer Pressure to Promote Cooperation
Mani, Ankur; Rahwan, Iyad; Pentland, Alex
2013-01-01
Cooperation in a large society of self-interested individuals is notoriously difficult to achieve when the externality of one individual's action is spread thin and wide on the whole society. This leads to the ‘tragedy of the commons’ in which rational action will ultimately make everyone worse-off. Traditional policies to promote cooperation involve Pigouvian taxation or subsidies that make individuals internalize the externality they incur. We introduce a new approach to achieving global cooperation by localizing externalities to one's peers in a social network, thus leveraging the power of peer-pressure to regulate behavior. The mechanism relies on a joint model of externalities and peer-pressure. Surprisingly, this mechanism can require a lower budget to operate than the Pigouvian mechanism, even when accounting for the social cost of peer pressure. Even when the available budget is very low, the social mechanisms achieve greater improvement in the outcome. PMID:23619166
Inducing peer pressure to promote cooperation.
Mani, Ankur; Rahwan, Iyad; Pentland, Alex
2013-01-01
Cooperation in a large society of self-interested individuals is notoriously difficult to achieve when the externality of one individual's action is spread thin and wide on the whole society. This leads to the 'tragedy of the commons' in which rational action will ultimately make everyone worse-off. Traditional policies to promote cooperation involve Pigouvian taxation or subsidies that make individuals internalize the externality they incur. We introduce a new approach to achieving global cooperation by localizing externalities to one's peers in a social network, thus leveraging the power of peer-pressure to regulate behavior. The mechanism relies on a joint model of externalities and peer-pressure. Surprisingly, this mechanism can require a lower budget to operate than the Pigouvian mechanism, even when accounting for the social cost of peer pressure. Even when the available budget is very low, the social mechanisms achieve greater improvement in the outcome.
Inducing Peer Pressure to Promote Cooperation
NASA Astrophysics Data System (ADS)
Mani, Ankur; Rahwan, Iyad; Pentland, Alex
2013-04-01
Cooperation in a large society of self-interested individuals is notoriously difficult to achieve when the externality of one individual's action is spread thin and wide on the whole society. This leads to the `tragedy of the commons' in which rational action will ultimately make everyone worse-off. Traditional policies to promote cooperation involve Pigouvian taxation or subsidies that make individuals internalize the externality they incur. We introduce a new approach to achieving global cooperation by localizing externalities to one's peers in a social network, thus leveraging the power of peer-pressure to regulate behavior. The mechanism relies on a joint model of externalities and peer-pressure. Surprisingly, this mechanism can require a lower budget to operate than the Pigouvian mechanism, even when accounting for the social cost of peer pressure. Even when the available budget is very low, the social mechanisms achieve greater improvement in the outcome.
Reaction of SO2 with OH in the atmosphere.
Long, Bo; Bao, Junwei Lucas; Truhlar, Donald G
2017-03-15
The OH + SO 2 reaction plays a critical role in understanding the oxidation of SO 2 in the atmosphere, and its rate constant is critical for clarifying the fate of SO 2 in the atmosphere. The rate constant of the OH + SO 2 reaction is calculated here by using beyond-CCSDT correlation energy calculations for a benchmark, validated density functional methods for direct dynamics, canonical variational transition state theory with anharmonicity and multidimensional tunneling for the high-pressure rate constant, and system-specific quantum RRK theory for pressure effects; the combination of these methods can compete in accuracy with experiments. There has been a long-term debate in the literature about whether the OH + SO 2 reaction is barrierless, but our calculations indicate a positive barrier with an transition structure that has an enthalpy of activation of 0.27 kcal mol -1 at 0 K. Our results show that the high-pressure limiting rate constant of the OH + SO 2 reaction has a positive temperature dependence, but the rate constant at low pressures has a negative temperature dependence. The computed high-pressure limiting rate constant at 298 K is 1.25 × 10 -12 cm 3 molecule -1 s -1 , which agrees excellently with the value (1.3 × 10 -12 cm 3 molecule -1 s -1 ) recommended in the most recent comprehensive evaluation for atmospheric chemistry. We show that the atmospheric lifetime of SO 2 with respect to oxidation by OH depends strongly on altitude (in the range 0-50 km) due to the falloff effect. We introduce a new interpolation procedure for fitting the combined temperature and pressure dependence of the rate constant, and it fits the calculated rate constants over the whole range with a mean unsigned error of only 7%. The present results provide reliable kinetics data for this specific reaction, and also they demonstrate convenient theoretical methods that can be reliable for predicting rate constants of other gas-phase reactions.
NASA Technical Reports Server (NTRS)
Vonpragenau, G. L. (Inventor)
1984-01-01
The configuration and relationship of the external propellant tank and solid rocket boosters of space transportation systems such as the space shuttle are described. The space shuttle system with the improved propellant tank is shown. The external tank has a forward pressure vessel for liquid hydrogen and an aft pressure vessel for liquid oxygen. The solid rocket boosters are joined together by a thrust frame which extends across and behind the external tank. The thrust of the orbiter's main rocket engines are transmitted to the aft portion of the external tank and the thrust of the solid rocket boosters are transmitted to the aft end of the external tank.
Yeung, Ching-Yan C; Holmes, David F; Thomason, Helen A; Stephenson, Christian; Derby, Brian; Hardman, Matthew J
2016-11-01
Pressure ulcers are complex wounds caused by pressure- and shear-induced trauma to skin and underlying tissues. Pressure-reducing devices, such as dressings, have been shown to successfully reduce pressure ulcer incidence, when used in adjunct to pressure ulcer preventative care. While pressure-reducing devices are available in a range of materials, with differing mechanical properties, understanding of how a material's mechanical properties will influence clinical efficacy remains limited. The aim of this study was to establish a standardized ex vivo model to allow comparison of the cell protection potential of two gel-like pressure-reducing devices with differing mechanical properties (elastic moduli of 77 vs. 35 kPa). The devices also displayed differing energy dissipation under compressive loading, and resisted strain differently under constant load in compressive creep tests. To evaluate biological efficacy we employed a new ex vivo porcine skin model, with a confirmed elastic moduli closely matching that of human skin (113 vs. 119 kPa, respectively). Static loads up to 20 kPa were applied to porcine skin ex vivo with subsequent evaluation of pressure-induced cell death and cytokine release. Pressure application alone increased the percentage of epidermal apoptotic cells from less than 2% to over 40%, and increased cellular secretion of the pro-inflammatory cytokine TNF-alpha. Co-application of a pressure-reducing device significantly reduced both cellular apoptosis and cytokine production, protecting against cellular damage. These data reveal new insight into the relationship between mechanical properties of pressure-reducing devices and their biological effects. After appropriate validation of these results in clinical pressure ulcer prevention with all tissue layers present between the bony prominence and external surface, this ex vivo porcine skin model could be widely employed to optimize design and evaluation of devices aimed at reducing pressure-induced skin damage. © 2016 The Authors Wound Repair and Regeneration published by Wiley Periodicals, Inc. on behalf of The Wound Healing Society.
Air ejector augmented compressed air energy storage system
Ahrens, F.W.; Kartsounes, G.T.
Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.
Mathes, Stephanie H; Wohlwend, Lorenz; Uebersax, Lorenz; von Mentlen, Roger; Thoma, Daniel S; Jung, Ronald E; Görlach, Christoph; Graf-Hausner, Ursula
2010-12-15
Gingival cells of the oral connective tissue are exposed to complex mechanical forces during mastication, speech, tooth movement and orthodontic treatments. Especially during wound healing following surgical procedures, internal and external forces may occur, creating pressure upon the newly formed tissue. This clinical situation has to be considered when developing biomaterials to augment soft tissue in the oral cavity. In order to pre-evaluate a collagen sponge intended to serve as a substitute for autogenous connective tissue grafts (CTGs), a dynamic bioreactor system was developed. Pressure and shear forces can be applied in this bioreactor in addition to a constant medium perfusion to cell-material constructs. Three-dimensional volume changes and stiffness of the matrices were analyzed. In addition, cell responses such as cell vitality and extracellular matrix (ECM) production were investigated. The number of metabolic active cells constantly increased under fully dynamic culture conditions. The sponges remained elastic even after mechanical forces were applied for 14 days. Analysis of collagen type I and fibronectin revealed a statistically significant accumulation of these ECM molecules (P < 0.05-0.001) when compared to static cultures. An increased expression of tenascin-c, indicating tissue remodeling processes, was observed under dynamic conditions only. The results indicate that the tested in vitro cell culture system was able to mimic both the biological and mechanical environments of the clinical situation in a healing wound. © 2010 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Prokhorov, V. M.; Gromnitskaya, E. L.
2018-04-01
The ultrasonic study results for dependence of the elastic wave velocities and second-order elasticity coefficients of the polycrystalline aluminum alloy AMg6 and its nanocomposite n-AMg6/C60 on hydrostatic pressure up to 1.6 GPa have been described. The ultrasonic research has been carried out using a highpressure ultrasonic piezometer based on the piston-cylinder device. The pressure derivatives of the secondorder elastic constants of these materials established in the present study have been compared with the results of the third-order elastic constants measurements of the test alloys using the Thurston-Brugger method. Involving available literature data, we determined the relationships between the pressure derivatives of the second-order elastic constants of the AMg6 alloy and the Mg-content and nanostructuring.
Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio
2014-09-01
Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).
The gaseous explosive reaction at constant pressure : the reaction order and reaction rate
NASA Technical Reports Server (NTRS)
Stevens, F W
1931-01-01
The data given in this report covers the explosive limits of hydrocarbon fuels. Incidental to the purpose of the investigation here reported, the explosive limits will be found to be expressed for the condition of constant pressure, in the fundamental terms of concentrations (partial pressures) of fuel and oxygen.
NASA Astrophysics Data System (ADS)
Walicka, A.; Walicki, E.; Jurczak, P.; Falicki, J.
2017-08-01
In the paper, the influence of both the bearing surfaces roughness as well as porosity of one bearing surface on the pressure distribution and load-carrying capacity of a curvilinear, externally pressurized, thrust bearing is discussed. The equations of motion of a pseudo-plastic Rabinowitsch fluid are used to derive the Reynolds equation. After general considerations on the flow in a bearing clearance and in a porous layer using the Morgan-Cameron approximation and Christensen theory of hydrodynamic lubrication with rough bearing surfaces the modified Reynolds equation is obtained. The analytical solution is presented; as a result one obtains the formulae expressing the pressure distribution and load-carrying capacity. Thrust radial and conical bearings, externally pressurized, are considered as numerical examples.
Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J
2016-01-01
Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p < 0.05 considered as significant. Perfusate flow remained constant in the Constant flow group, but was more than halved during hypothermia in the Constant PPA group concomitant with a more fold increase in PVR. In the Constant flow group, Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased hemoconcentration, but the changes were less in hypothermic lungs perfused at constant PPA.
The effect of ignition location on explosion venting of hydrogen-air mixtures
NASA Astrophysics Data System (ADS)
Cao, Y.; Guo, J.; Hu, K.; Xie, L.; Li, B.
2017-07-01
The effect of ignition location and vent burst pressure on the internal pressure-time history and external flame propagation was investigated for vented explosions of hydrogen-air mixtures in a small cylindrical vessel. A high-speed camera was used to record videos of the external flame while pressure transducers were used to record pressure-time histories. It was found that central ignition always leads to the maximum internal peak overpressure, and front ignition resulted in the lowest value of internal peak overpressure. The internal peak overpressures are increased corresponding to the increase in the vent burst pressure in the cases of central and rear ignition. Because of the effect of acoustic oscillations, the phenomenon of oscillations is observed in the internal pressure profile for the case of front ignition. The pressure oscillations for the cases of rear and central ignition are triggered by external explosions. The behavior of flames outside the chamber is significantly associated with the internal pressure of the chamber so that the velocity of the jet flame is closely related to the internal overpressure peak.
A root-mean-square pressure fluctuations model for internal flow applications
NASA Technical Reports Server (NTRS)
Chen, Y. S.
1985-01-01
A transport equation for the root-mean-square pressure fluctuations of turbulent flow is derived from the time-dependent momentum equation for incompressible flow. Approximate modeling of this transport equation is included to relate terms with higher order correlations to the mean quantities of turbulent flow. Three empirical constants are introduced in the model. Two of the empirical constants are estimated from homogeneous turbulence data and wall pressure fluctuations measurements. The third constant is determined by comparing the results of large eddy simulations for a plane channel flow and an annulus flow.
The p- T phase diagram of KNbO 3 by a dielectric constant measurement
NASA Astrophysics Data System (ADS)
Kobayashi, Y.; Endo, S.; Deguchi, K.; Ming, L. C.; Zou, G.
2001-11-01
A dielectric constant measurement was carried out on perovskite-type ferroelectrics KNbO 3 over a wide range of temperature under high pressure. The temperature- and pressure-dependence of the dielectric constant clarified that all temperatures of the transitions from the ferroelectric rhombohedral to orthorhombic, to tetragonal and then to the paraelectric cubic phase, decrease with increasing pressure. These results indicate that the orthorhombic-tetragonal transition takes place at 8.5 GPa and the tetragonal-cubic transition at 11 GPa, at room temperature.
Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy
NASA Technical Reports Server (NTRS)
Edwards, Lawrence G.; Haberbusch, Mark
1993-01-01
The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.
NASA Technical Reports Server (NTRS)
Bosco, S. R.; Nava, D. F.; Brobst, W. D.; Stief, L. J.
1984-01-01
The absolute rate constants for the reaction between the NH2 free radical and acetylene and ethylene is measured experimentally using a flash photolysis technique. The constant is considered to be a function of temperature and pressure. At each temperature level of the experiment, the observed pseudo-first-order rate constants were assumed to be independent of flash intensity. The results of the experiment indicate that the bimolecular rate constant for the NH2 + C2H2 reaction increases with pressure at 373 K and 459 K but not at lower temperatures. Results near the pressure limit conform to an Arrhenius expression of 1.11 (+ or -) 0.36 x 10 to the -13th over the temperature range from 241 to 459 K. For the reaction NH2 + C2H4, a smaller rate of increase in the bimolecular rate constant was observed over the temperature range 250-465 K. The implications of these results for current theoretical models of NH2 + C2H2 (or H4) reactions in the atmospheres of Jupiter and Saturn are discussed.
Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton
2015-02-01
The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Finite element modelling of sound transmission from outer to inner ear.
Areias, Bruno; Santos, Carla; Natal Jorge, Renato M; Gentil, Fernanda; Parente, Marco Pl
2016-11-01
The ear is one of the most complex organs in the human body. Sound is a sequence of pressure waves, which propagates through a compressible media such as air. The pinna concentrates the sound waves into the external auditory meatus. In this canal, the sound is conducted to the tympanic membrane. The tympanic membrane transforms the pressure variations into mechanical displacements, which are then transmitted to the ossicles. The vibration of the stapes footplate creates pressure waves in the fluid inside the cochlea; these pressure waves stimulate the hair cells, generating electrical signals which are sent to the brain through the cochlear nerve, where they are decoded. In this work, a three-dimensional finite element model of the human ear is developed. The model incorporates the tympanic membrane, ossicular bones, part of temporal bone (external auditory meatus and tympanic cavity), middle ear ligaments and tendons, cochlear fluid, skin, ear cartilage, jaw and the air in external auditory meatus and tympanic cavity. Using the finite element method, the magnitude and the phase angle of the umbo and stapes footplate displacement are calculated. Two slightly different models are used: one model takes into consideration the presence of air in the external auditory meatus while the other does not. The middle ear sound transfer function is determined for a stimulus of 60 dB SPL, applied to the outer surface of the air in the external auditory meatus. The obtained results are compared with previously published data in the literature. This study highlights the importance of external auditory meatus in the sound transmission. The pressure gain is calculated for the external auditory meatus.
Responses of Atriplex spongiosa and Suaeda monoica to Salinity
Storey, Richard; Jones, R. Gareth Wyn
1979-01-01
The growth and tissue water, K+, Na+, Cl−, proline and glycinebetaine contents of the shoots and roots of two Chenopodiaceae, Atriplex spongiosa and Suaeda monoica have been measured over a range of external NaCl salinities. Both species showed some fresh weight response to low salinity mainly due to increased succulence. S. monoica showed both a greater increase in succulence (at low salinities) and tolerance of high salinities than A. spongiosa. Both species had high affinities for Na+ and maintained constant but low shoot K+ contents with increasing salinity. These trends were more marked with S. monoica in which Na+ stimulated the accumulation of K+ in roots. An association between high leaf Na+ accumulation, high osmotic pressure, succulence, and a positive growth response at low salinities was noted. Proline accumulation was observed in shoot tissues with suboptimal water contents. High glycinebetaine contents were found in the shoots of both species. These correlated closely with the sap osmotic pressure and it is suggested that glycinebetaine is the major cytoplasmic osmoticum (with K+ salts) in these species at high salinities. Na+ salts may be preferentially utilized as vacuolar osmotica. PMID:16660671
NASA Astrophysics Data System (ADS)
El Ghazi, Haddou; John Peter, A.
2017-04-01
Hydrogenic-like donor-impurity related self and induced polarizations, bending energy and photo-ionization cross section in spherical core/shell zinc blende (In,Ga)N/GaN are computed. Based on the variational approach and within effective-mass and one parabolic approximations, the calculations are made under finite potential barrier taking into account of the discontinuity of the effective-mass and the constant dielectric. The photo-ionization cross section is studied according to the photon incident energy considering the effects of hydrostatic pressure, applied electric field, structure's radius, impurity's position and indium composition in the core. It is obtained that the influences mentioned above lead to either blue shifts or redshifts of the resonant peak of the photo-ionization cross section spectrum. The unusual behavior related to the structure radius is discussed which is as a consequence of the finite potential confinement. We have shown that the photo-ionization cross section can be controlled with adjusting the internal and external factors. These properties can be useful for producing some device applications such as quantum dot infrared photodetectors.
NASA Astrophysics Data System (ADS)
1992-09-01
ESDU 92026 provides a procedure for the design and performance analysis of the bearings with five or more identical equally-spaced rectangular recesses (or pockets) fed by identical capillary restrictors from a constant pressure supply. The method takes account of stiffness and overload capacity requirements and determines the bearing overall size and proportions from the required load, speed and shaft diameter, recommends the clearance and supply pressure, and defines the recess dimensions and capillary restrictor size from the properties of the chosen lubricant. Equations and charts allow prediction of the journal displacement under load, the power loss, the lubricant flow rate, and the bearing and lubricant temperatures. The method applies to laminar flow and guidance is given for assessing the onset of non-laminar flow in the bearing and restrictors. Guidance is also given on the likelihood of bearing-induced instability. The user is assisted by flowcharts in applying the method, and two practical worked examples illustrate the procedure. ESDU 92037 introduces a FORTRAN program that implements the method, and magnetic media are available in ESDUpac A9237.
ESTIMATION OF CARBOXYLIC ACID ESTER HYDROLYSIS RATE CONSTANTS
SPARC chemical reactivity models were extended to calculate hydrolysis rate constants for carboxylic acid esters from molecular structure. The energy differences between the initial state and the transition state for a molecule of interest are factored into internal and external...
Ignition Delay of Combustible Materials in Normoxic Equivalent Environments
NASA Technical Reports Server (NTRS)
McAllister, Sara; Fernandez-Pello, Carlos; Ruff, Gary; Urban, David
2009-01-01
Material flammability is an important factor in determining the pressure and composition (fraction of oxygen and nitrogen) of the atmosphere in the habitable volume of exploration vehicles and habitats. The method chosen in this work to quantify the flammability of a material is by its ease of ignition. The ignition delay time was defined as the time it takes a combustible material to ignite after it has been exposed to an external heat flux. Previous work in the Forced Ignition and Spread Test (FIST) apparatus has shown that the ignition delay in the currently proposed space exploration atmosphere (approximately 58.6 kPa and32% oxygen concentration) is reduced by 27% compared to the standard atmosphere used in the Space Shuttle and Space Station. In order to determine whether there is a safer environment in terms of material flammability, a series of piloted ignition delay tests using polymethylmethacrylate (PMMA) was conducted in the FIST apparatus to extend the work over a range of possible exploration atmospheres. The exploration atmospheres considered were the normoxic equivalents, i.e. reduced pressure conditions with a constant partial pressure of oxygen. The ignition delay time was seen to decrease as the pressure was reduced along the normoxic curve. The minimum ignition delay observed in the normoxic equivalent environments was nearly 30% lower than in standard atmospheric conditions. The ignition delay in the proposed exploration atmosphere is only slightly larger than this minimum. Interms of material flammability, normoxic environments with a higher pressure relative to the proposed pressure would be desired.
Jackman, A P; Green, J F
1990-01-01
We developed and tested a new two-compartment serial model of the arterial vasculature which unifies the capacitance (downstream arterial compliance) and waterfall (constant downstream pressure load) theories of blood flow through the arteries. In this model, blood drains from an upstream compliance through a resistance into a downstream compliance which empties into the veins through a downstream resistance which terminates in a constant pressure load. Using transient arterial pressure data obtained from an isolated canine hindlimb preparation, we tested this model, using a stop-flow technique. Numerical parameter estimation techniques were used to estimate the physiologic parameters of the model. The downstream compliance was found to be more than ten times larger than the upstream compliance and the constant pressure load was significantly above venous pressures but decreased in response to vasodilation. Our results support the applicability of both the capacitance and waterfall theories.
The impact of constant light on the estrous cycle of the rat.
Campbell, C S; Schwartz, N B
1980-04-01
The initial effects of constant bright light on the events of the rat estrous cycle were monitored in order to examine the interdependence of the hormonal and behavioral rhythms which comprise the cycle. Females exposed to constant bright light for only one cycle either failed to ovulate or showed a delay in the hormonal and behavioral events of the cycle as well as in ovulation. Females exposed to constant light for two cycles 1) failed to ovulate, 2) showed an advancement, or 3) showed a delay in the hormonal events of the estrous cycle and ovulation. Vaginal cytology and the onset of locomotor activity did not maintain their normal temporal relationships with the other events of the estrous cycle in constant light. In spite of the absence of an external timing signal, the majority of hormonal rhythms maintained their normal phase relationships and showed little sign of internal desynchrony. Ovaries in many animals showed high rates of follicular atresia early in the cycle, suggesting that the effects of bright constant light are far more complex than can be attributed to a simple absence of an external timing signal.
Duerr, K; Troeppner, O; Olah, J; Li, J; Zahl, A; Drewello, T; Jux, N; Harvey, J N; Ivanović-Burmazović, I
2012-01-14
The solution behavior of iron(III) and iron(II) complexes of 5(4),10(4),15(4),20(4)-tetra-tert-butyl-5,10,15,20-tetraphenylporphyrin (H(2)tBuTPP) and the reaction with superoxide (KO(2)) in DMSO have been studied in detail. Applying temperature and pressure dependent NMR studies, the thermodynamics of the low-spin/high-spin equilibrium between bis- and mono-DMSO Fe(II) forms have been quantified (K(DMSO) = 0.082 ± 0.002 at 298.2 K, ΔH° = +36 ± 1 kJ mol(-1), ΔS° = +101 ± 4 J K(-1) mol(-1), ΔV° = +16 ± 2 cm(3) mol(-1)). This is a key activation step for substitution and inner-sphere electron transfer. The superoxide binding constant to the iron(II) form of the studied porphyrin complex was found to be (9 ± 0.5) × 10(3) M(-1), and does not change significantly in the presence of the externally added crown ether in DMSO (11 ± 4) × 10(3) M(-1). The rate constants for the superoxide binding (k(on) = (1.30 ± 0.01) × 10(5) M(-1) s(-1)) and release (k(off) = 11.6 ± 0.7 s(-1)) are not affected by the presence of the external crown ether in solution. The resulting iron(II)-superoxide adduct has been characterized (mass spectrometry, EPR, high-pressure UV/Vis spectroscopy) and upon controlled addition of a proton source it regenerates the starting iron(II) complex. Based on DFT calculations, the reaction product without neighboring positive charge has iron(II)-superoxo character in both high-spin side-on and low-spin end-on forms. The results are compared to those obtained for the analogous complex with covalently attached crown ether, and more general conclusions regarding the spin-state equilibrium of iron(II) porphyrins, their reaction with superoxide and the electronic structure of the product species are drawn.
Computational study of single-expansion-ramp nozzles with external burning
NASA Astrophysics Data System (ADS)
Yungster, Shaye; Trefny, Charles J.
1992-04-01
A computational investigation of the effects of external burning on the performance of single expansion ramp nozzles (SERN) operating at transonic speeds is presented. The study focuses on the effects of external heat addition and introduces a simplified injection and mixing model based on a control volume analysis. This simplified model permits parametric and scaling studies that would have been impossible to conduct with a detailed CFD analysis. The CFD model is validated by comparing the computed pressure distribution and thrust forces, for several nozzle configurations, with experimental data. Specific impulse calculations are also presented which indicate that external burning performance can be superior to other methods of thrust augmentation at transonic speeds. The effects of injection fuel pressure and nozzle pressure ratio on the performance of SERN nozzles with external burning are described. The results show trends similar to those reported in the experimental study, and provide additional information that complements the experimental data, improving our understanding of external burning flowfields. A study of the effect of scale is also presented. The results indicate that combustion kinetics do not make the flowfield sensitive to scale.
Computational study of single-expansion-ramp nozzles with external burning
NASA Technical Reports Server (NTRS)
Yungster, Shaye; Trefny, Charles J.
1992-01-01
A computational investigation of the effects of external burning on the performance of single expansion ramp nozzles (SERN) operating at transonic speeds is presented. The study focuses on the effects of external heat addition and introduces a simplified injection and mixing model based on a control volume analysis. This simplified model permits parametric and scaling studies that would have been impossible to conduct with a detailed CFD analysis. The CFD model is validated by comparing the computed pressure distribution and thrust forces, for several nozzle configurations, with experimental data. Specific impulse calculations are also presented which indicate that external burning performance can be superior to other methods of thrust augmentation at transonic speeds. The effects of injection fuel pressure and nozzle pressure ratio on the performance of SERN nozzles with external burning are described. The results show trends similar to those reported in the experimental study, and provide additional information that complements the experimental data, improving our understanding of external burning flowfields. A study of the effect of scale is also presented. The results indicate that combustion kinetics do not make the flowfield sensitive to scale.
Stretchable Dual-Capacitor Multi-Sensor for Touch-Curvature-Pressure-Strain Sensing.
Jin, Hanbyul; Jung, Sungchul; Kim, Junhyung; Heo, Sanghyun; Lim, Jaeik; Park, Wonsang; Chu, Hye Yong; Bien, Franklin; Park, Kibog
2017-09-07
We introduce a new type of multi-functional capacitive sensor that can sense several different external stimuli. It is fabricated only with polydimethylsiloxane (PDMS) films and silver nanowire electrodes by using selective oxygen plasma treatment method without photolithography and etching processes. Differently from the conventional single-capacitor multi-functional sensors, our new multi-functional sensor is composed of two vertically-stacked capacitors (dual-capacitor). The unique dual-capacitor structure can detect the type and strength of external stimuli including curvature, pressure, strain, and touch with clear distinction, and it can also detect the surface-normal directionality of curvature, pressure, and touch. Meanwhile, the conventional single-capacitor sensor has ambiguity in distinguishing curvature and pressure and it can detect only the strength of external stimulus. The type, directionality, and strength of external stimulus can be determined based on the relative capacitance changes of the two stacked capacitors. Additionally, the logical flow reflected on a tree structure with its branches reaching the direction and strength of the corresponding external stimulus unambiguously is devised. This logical flow can be readily implemented in the sensor driving circuit if the dual-capacitor sensor is commercialized actually in the future.
High resolution gas volume change sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dirckx, Joris J. J.; Aernouts, Jef E. F.; Aerts, Johan R. M.
2007-05-15
Changes of gas quantity in a system can be measured either by measuring pressure changes or by measuring volume changes. As sensitive pressure sensors are readily available, pressure change is the commonly used technique. In many physiologic systems, however, buildup of pressure influences the gas exchange mechanisms, thus changing the gas quantity change rate. If one wants to study the gas flow in or out of a biological gas pocket, measurements need to be done at constant pressure. In this article we present a highly sensitive sensor for quantitative measurements of gas volume change at constant pressure. The sensor ismore » based on optical detection of the movement of a droplet of fluid enclosed in a capillary. The device is easy to use and delivers gas volume data at a rate of more than 15 measurements/s and a resolution better than 0.06 {mu}l. At the onset of a gas quantity change the sensor shows a small pressure artifact of less than 15 Pa, and at constant change rates the pressure artifact is smaller than 10 Pa or 0.01% of ambient pressure.« less
Elastic constants and pressure derivative of elastic constants of Si1-xGex solid solution
NASA Astrophysics Data System (ADS)
Jivani, A. R.; Baria, J. K.; Vyas, P. S.; Jani, A. R.
2013-02-01
Elastic properties of Si1-xGex solid solution with arbitrary (atomic) concentration (x) are studied using the pseudo-alloy atom model based on the pseudopotential theory and on the higher-order perturbation scheme with the application of our own proposed model potential. We have used local-field correction function proposed by Sarkar et al to study Si-Ge system. The Elastic constants and pressure derivatives of elastic constants of the solid solution is investigated with different concentration x of Ge. It is found in the present study that the calculated numerical values of the aforesaid physical properties of Si-Ge system are function of x. The elastic constants (C11, C12 and C44) decrease linearly with increase in concentration x and pressure derivative of elastic constants (C11, C12 and C44) increase with the concentration x of Ge. This study provides better set of theoretical results for such solid solution for further comparison either with theoretical or experimental results.
Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2015-01-01
A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. Compared to traditional external-compression, two-dimensional and axisymmetric inlets, streamline-traced inlets promise reduced cowl wave drag and sonic boom, but at the expense of reduced total pressure recovery and increased total pressure distortion. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion.
Externally Pressurized Journal Gas Bearings
NASA Technical Reports Server (NTRS)
Laub, John H.
1959-01-01
Externally pressurized gas-lubricated bearings with multiple orifice feed are investigated. An analytical treatment is developed for a semi-cylindrical bearing with 9 orifices and for a cylindrical journal bearing with 192 radial and 24 axial orifices. Experiments are described on models of the two bearing configurations with specially designed fixtures which incorporate pneumatic loading and means for determining pressure profiles, gas flow and gap height. The correlation between theory and experiment is satisfactory.
Static-stress analysis of dual-axis safety vessel
NASA Astrophysics Data System (ADS)
Bultman, D. H.
1992-11-01
An 8 ft diameter safety vessel, made of HSLA-100 steel, is evaluated to determine its ability to contain the quasi-static residual pressure from a high explosive (HE) blast. The safety vessel is designed for use with the Dual-Axis Radiographic Hydrotest (DARHT) facility being developed at Los Alamos National Laboratory. A smaller confinement vessel fits inside the safety vessel and contains the actual explosion, and the safety vessel functions as a second layer of containment in the unlikely case of a confinement vessel leak. The safety vessel is analyzed as a pressure vessel based on the ASME Boiler and Pressure Vessel Code, Section 8, Division 1, and the Welding Research Council Bulletin, WRC107. Combined stresses that result from internal pressure and external loads on nozzles are calculated and compared to the allowable stresses for HSLA-100 steel. Results confirm that the shell and nozzle components are adequately designed for a static pressure of 830 psi, plus the maximum expected external loads. Shell stresses at the 'shell to nozzle' interface, produced from external loads on the nozzles, were less than 700 psi. The maximum combined stress resulting from the internal pressure plus external loads was 17,384 psi, which is significantly less than the allowable stress of 42,375 psi for HSLA-100 steel.
Thompson, D S; Wilmshurst, P; Juul, S M; Waldron, C B; Jenkins, B S; Coltart, D J; Webb-Peploe, M M
1983-01-01
High fidelity measurements of left ventricular pressure were made at increasing pacing rates in 21 patients with hypertrophic cardiomyopathy and a control group of 11 patients investigated for chest pain who proved to have normal hearts. In both groups the fall in pressure during isovolumic relaxation from the point of min dp/dt approximated closely to a monoexponential, and could be described by a time constant and asymptote. The time constant shortened and the asymptote increased as heart rate rose in both groups. The time constant was longer and min dp/dt less in the cardiomyopathy group than controls at all heart rates. In the cardiomyopathy patients min dp/dt, but not the time constant, was related to systolic pressure. During pacing, eight cardiomyopathy patients developed metabolic evidence of myocardial ischaemia, but indices of relaxation did not differ between these eight and the other 13 either at basal heart rate or the highest pacing rate. In 10 cardiomyopathy patients measurements were repeated at comparable pacing rates after propranolol (0.2 mg/kg). Left ventricular end-diastolic pressure and indices of contractility decreased after the drug, but the time constant did not change. Eight patients received verapamil (20 mg) after which there were substantial reductions in systolic pressure and contractility. Min dp/dt decreased in proportion to systolic pressure, but the time constant was unchanged. At the highest pacing rate before drug administration three patients had abnormal lactate extraction which was corrected by either propranolol (one patient) or verapamil (two patients). Despite abolition of metabolic evidence of ischaemia, relaxation did not improve. It is concluded that abnormal isovolumic relaxation is common in patients with hypertrophic cardiomyopathy, but its severity correlates poorly with other features of the disease. Abnormal relaxation is not the result of ischaemia, and pressure derived indices of relaxation do not improve after the administration of propranolol or verapamil. PMID:6681978
NASA Technical Reports Server (NTRS)
Cohn, R. B. (Inventor)
1983-01-01
A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.
Ultra-high pressure waterjets efficient in removing coatings
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
Little if any thought was given to pipeline rehabilitation 50 years, a time when pipe manufacturers often coated the external diameter of pipe with coal tar to help eliminate corrosion. Unfortunately, contractors rehabilitating these pipelines today encounter major difficulties when attempting to remove coal tar with traditional removal processes. A leading pipeline rehabilitation firm, F.F. Yockey Company, Inc. of Magnolia, Texas, faced a constant challenge stripping coal tar with rotating knives and brushes. The process generated heat that melted the tar and caused the machines to jam. Another problem was the damage to the substrate caused by the friction-based cleaningmore » techniques of rotating knives and brushes. The knives also failed to completely clean the substrate, leaving behind a significant amount of residue. Contractors learned that new coating bonded poorly to the substrates covered with residual contaminants, thus yielding unsatisfactory results. As he looked for a solution, Dick Yockey, president and CEO of R.F. Yockey, began exploring the use of ultra-high pressure waterjet surface preparation equipment. This system involved water pressurized at levels ranging from 35,000 to 55,000 psi. The water travels through small orifices in a high-speed rotating nozzle, forming a cohesive stream of water. This paper reviews the design and performance of this system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ulvestad, A.; Welland, M. J.; Cha, W.
Crystallographic imperfections can significantly alter material properties and responses to external stimuli, including solute induced phase transformations and crystal growth and dissolution . Despite recent progress in imaging defects using both electron and x-ray techniques, in situ three-dimensional imaging studies of defect dynamics, necessary to understand and engineer nanoscale processes, remains challenging. Here, we report in situ three-dimensional imaging of defect dynamics during the hydriding phase transformation of individual palladium nanocrystals by Bragg Coherent Diffractive Imaging (BCDI) . During constant pressure experiments, we observed that the phase transformation begins after the nucleation of dislocations in large (300 nm) particles. Themore » 3D dislocation network shows that dislocations are close to the phase boundary. The 3D phase morphology resolved by BCDI suggests that the hydrogen-rich phase is more similar to a spherical cap on the hydrogen-poor phase than the core-shell model commonly assumed. We substantiate this conclusion using 3D phase field modeling and demonstrate how phase morphology affects the critical size for dislocation nucleation. We determine the size dependence of the transformation pressure for large (150-300 nm) palladium nanocrystals using variable pressure experiments. Our results reveal a pathway for solute induced structural phase transformations in nanocrystals and demonstrate BCDI as a novel method for understanding dislocation dynamics in phase transforming systems at the nanoscale.« less
Enhancing separation in short-capillary electrophoresis via pressure-driven backflow.
Tian, Miaomiao; Wang, Yujia; Mohamed, Amara Camara; Guo, Liping; Yang, Li
2015-07-01
We present a novel easy-to-operate and efficient method to improve the separation efficiency in short-capillary electrophoresis by introducing steady backflow to counterbalance electro-osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run-to-run repeatability and capillary-to-capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure-driven backflow to enhance separation efficiency in short-capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cesana, Giancarlo; Sega, Roberto; Ferrario, Marco; Chiodini, Paolo; Corrao, Giovanni; Mancia, Giuseppe
2003-01-01
The extent to which psychosocial stress concurs to raise blood pressure is still uncertain. Here the association between job strain and office blood pressure in a pooled analysis of four population samples from northern Italy is assessed. Four surveys assessing prevalence of major coronary risk factors were performed in 1986, 1990, 1991, and 1993 in area "Brianza" (Milan), a World Health Organization-MONItoring cardiovascular disease (WHO-MONICA) Project collaborating center. Ten year age- and gender-stratified independent samples were randomly recruited from the 25- to 64-year-old residents. The methods used to assess coronary risk factors strictly adhered to the MONICA manual, were kept constant, and underwent internal and external quality controls. Job strain was investigated through the administration to employed participants of a questionnaire derived from the Karasek model, assessing job demand/control latitude. Analysis was restricted to 25- to 54-year-old participants, untreated for hypertension (1799 men and 1010 women). Among men, there was a 3 mm Hg increase of systolic blood pressure (p<.001) moving from low to high strain job categories. This difference was independent from age, education, body mass index, alcohol intake, smoking habits, leisure time physical activity, and survey. No relevant differences among job strain categories were found in women and for diastolic blood pressure in both gender groups. These results carried out on a large population-based sample confirm previous findings obtained adopting ambulatory blood pressure measurements in more restricted samples of population or patients. Further research is needed to clarify the relationship between perceived work stress and blood pressure in women.
RHYTHMICITY IN THE PROTOPLASMIC STREAMING OF A SLIME MOLD, PHYSARUM POLYCEPHALUM
Kishimoto, Uichiro
1958-01-01
The electric potential difference (1 to 15 mv.) between two loci of the slime mold connected with a strand of protoplasm changes rhythmically with the same period (60 to 180 seconds) as that of back and forth protoplasmic streaming along the strand. When atmospheric pressure at a part of the plasmodium is increased (about 10 cm. H2O), the electric potential at this part becomes positive (0 to 20 mv.) to another part with a time constant of 2 to 15 minutes. If the atmospheric pressure at a part of the plasmodium is changed (about 10 cm. H2O) periodically, the electric potential rhythm also changes with the same period as that of the applied pressure change, and the amplitude of the former grows to a new level (i.e., forced oscillation). The electric potential rhythm, in this case, is generally delayed about 90° in phase angle from the external pressure change. The period of the electric potential rhythm which coincided with that of the pressure change is maintained for a while after stopping the application of the pressure change, if the period is not much different from the native flow rhythm. Such a pressure effect is brought about by the forced transport of protoplasm and is reversible as a rule. In the statistical analysis made by Kishimoto (1958) and in the rheological treatment made in the report, the rhythmic deformation of the contractile protein networks is supposed to be the cause of the protoplasmic flow along the strand and of the electric potential rhythm. The role of such submicroscopic networks in the protoplasm in various kinds of protoplasmic movement is emphasized. PMID:13563809
NASA Astrophysics Data System (ADS)
Timpmann, Kõu; Kangur, Liina; Lõhmus, Ants; Freiberg, Arvi
2017-07-01
The optical absorption and fluorescence response to external high pressure of the reaction center membrane chromoprotein complex from the wild-type non-sulfur photosynthetic bacterium Rhodobacter sphaeroides was investigated using the native pigment cofactors as local molecular probes of the reaction center structure at physiological (ambient) and cryogenic (79 K) temperatures. In detergent-purified complexes at ambient temperature, abrupt blue shift and accompanied broadening of the special pair band was observed at about 265 MPa. These reversible in pressure features were assigned to a pressure-induced rupture of a lone hydrogen bond that binds the photo-chemically active L-branch primary electron donor bacteriochlorophyll cofactor to the surrounding protein scaffold. In native membrane-protected complexes the hydrogen bond rupture appeared significantly restricted and occurred close to about 500 MPa. The free energy change associated with the rupture of the special pair hydrogen bond in isolate complexes was estimated to be equal to about 12 kJ mol-1. In frozen samples at cryogenic temperatures the hydrogen bond remained apparently intact up to the maximum utilized pressure of 600 MPa. In this case, however, heterogeneous spectral response of the cofactors from the L-and M-branches was observed due to anisotropic build-up of the protein structure. While in solid phase, the special pair fluorescence as a function of pressure exactly followed the respective absorption spectrum at a constant Stokes shift, at ambient temperature, the two paths began to deviate strongly from one other at the hydrogen bond rupture pressure. This effect was tentatively interpreted by different emission properties of hydrogen-bound and hydrogen-unbound special pair exciton states.
Compartmentalized storage tank for electrochemical cell system
NASA Technical Reports Server (NTRS)
Piecuch, Benjamin Michael (Inventor); Dalton, Luke Thomas (Inventor)
2010-01-01
A compartmentalized storage tank is disclosed. The compartmentalized storage tank includes a housing, a first fluid storage section disposed within the housing, a second fluid storage section disposed within the housing, the first and second fluid storage sections being separated by a movable divider, and a constant force spring. The constant force spring is disposed between the housing and the movable divider to exert a constant force on the movable divider to cause a pressure P1 in the first fluid storage section to be greater than a pressure P2 in the second fluid storage section, thereby defining a pressure differential.
Spherical shells buckling to the sound of music
NASA Astrophysics Data System (ADS)
Lee, Anna; Marthelot, Joel; Reis, Pedro
We study how the critical buckling load of spherical elastic shells can be modified by a fluctuating external pressure field. In our experiments, we employ thin elastomeric shells of nearly uniform thickness fabricated by the coating of a hemispherical mold with a polymer solution, which upon curing yields elastic structures. A shell is submerged in a water bath and loaded quasi-statically until buckling occurs by reducing its inner volume with a syringe pump. Simultaneously, a plunger connected to an electromagnetic shaker is placed above the shell and driven sinusoidally to create a fluctuating external pressure field that can excite dynamic vibration modes of the shell. These dynamic modes induce effective compressive stresses, in addition to those from the inner pressure loading, which can modify the critical conditions for the onset of buckling. We systematically quantify how the frequency and amplitude of the external driving affects the buckling strength of our shells. In specific regions of the parameter space, we find that pressure fluctuations can result in large reductions of the critical buckling pressure. This is analogous to the classic knock-down effect in shells due to intrinsic geometric imperfections, albeit now in a way that can be controlled externally.
NASA Astrophysics Data System (ADS)
Haghi, Hosein; Baumgardt, Holger; Kroupa, Pavel; Grebel, Eva K.; Hilker, Michael; Jordi, Katrin
2009-05-01
We investigate the mean velocity dispersion and the velocity dispersion profile of stellar systems in modified Newtonian dynamics (MOND), using the N-body code N-MODY, which is a particle-mesh-based code with a numerical MOND potential solver developed by Ciotti, Londrillo & Nipoti. We have calculated mean velocity dispersions for stellar systems following Plummer density distributions with masses in the range of 104 to 109Msolar and which are either isolated or immersed in an external field. Our integrations reproduce previous analytic estimates for stellar velocities in systems in the deep MOND regime (ai, ae << a0), where the motion of stars is either dominated by internal accelerations (ai >> ae) or constant external accelerations (ae >> ai). In addition, we derive for the first time analytic formulae for the line-of-sight velocity dispersion in the intermediate regime (ai ~ ae ~ a0). This allows for a much-improved comparison of MOND with observed velocity dispersions of stellar systems. We finally derive the velocity dispersion of the globular cluster Pal14 as one of the outer Milky Way halo globular clusters that have recently been proposed as a differentiator between Newtonian and MONDian dynamics.
What is limiting more flexible fire management—public or agency pressure?
Toddi A. Steelman; Sarah M. McCaffrey
2011-01-01
Conventional wisdom within American federal fire management agencies suggests that external influence such as community or political pressure for aggressive suppression are key factors circumscribing the ability to execute less aggressive fire management strategies. Thus, a better understanding of external constraints on fire management options is essential. This...
Pressure dependence of the refractive index and dielectric constant in a fluoroperovskite, KMgF3
NASA Astrophysics Data System (ADS)
Uchino, Kenji; Nomura, Shoichiro; Vedam, K.; Newnham, Robert E.; Cross, Leslie E.
1984-06-01
The hydrostatic-pressure dependence of the refractive index and the low-frequency dielectric constant of a perovskite-type single crystal, KMgF3, have been determined at room temperature. The refractive index n for λ=589.3 nm increases monotonously in proportion to pressure p with a slope of ∂n∂p=2.46×10-4kbar-1. On the other hand, the dielectric constant at 10 kHz decreases with increasing pressure, from which the electric-displacement-related electrostrictive coefficient Qh (=Q11+2Q12) is calculated as 0.24 m4 C-2. These data are compared with the ∂n∂p values and the Qh coefficients of various alkali fluorides and perovskite oxides.
Pressure-driven flow of a Herschel-Bulkley fluid with pressure-dependent rheological parameters
NASA Astrophysics Data System (ADS)
Panaseti, Pandelitsa; Damianou, Yiolanda; Georgiou, Georgios C.; Housiadas, Kostas D.
2018-03-01
The lubrication flow of a Herschel-Bulkley fluid in a symmetric long channel of varying width, 2h(x), is modeled extending the approach proposed by Fusi et al. ["Pressure-driven lubrication flow of a Bingham fluid in a channel: A novel approach," J. Non-Newtonian Fluid Mech. 221, 66-75 (2015)] for a Bingham plastic. Moreover, both the consistency index and the yield stress are assumed to be pressure-dependent. Under the lubrication approximation, the pressure at zero order depends only on x and the semi-width of the unyielded core is found to be given by σ(x) = -(1 + 1/n)h(x) + C, where n is the power-law exponent and the constant C depends on the Bingham number and the consistency-index and yield-stress growth numbers. Hence, in a channel of constant width, the width of the unyielded core is also constant, despite the pressure dependence of the yield stress, and the pressure distribution is not affected by the yield-stress function. With the present model, the pressure is calculated numerically solving an integro-differential equation and then the position of the yield surface and the two velocity components are computed using analytical expressions. Some analytical solutions are also derived for channels of constant and linearly varying widths. The lubrication solutions for other geometries are calculated numerically. The implications of the pressure-dependence of the material parameters and the limitations of the method are discussed.
Alexe-Ionescu, A L; Barbero, G; Lelidis, I
2014-08-28
We consider the influence of the spatial dependence of the ions distribution on the effective dielectric constant of an electrolytic solution. We show that in the linear version of the Poisson-Nernst-Planck model, the effective dielectric constant of the solution has to be considered independent of any ionic distribution induced by the external field. This result follows from the fact that, in the linear approximation of the Poisson-Nernst-Planck model, the redistribution of the ions in the solvent due to the external field gives rise to a variation of the dielectric constant that is of the first order in the effective potential, and therefore it has to be neglected in the Poisson's equation that relates the actual electric potential across the electrolytic cell to the bulk density of ions. The analysis is performed in the case where the electrodes are perfectly blocking and the adsorption at the electrodes is negligible, and in the absence of any ion dissociation-recombination effect.
Weppner, Justin
2013-08-01
The military medical community has promoted use of Foley catheter balloon tamponade in the initial management of vascular injury owing to neck or maxillofacial trauma. The aim of the study was to compare outcomes with Foley catheter tamponade with those obtained with traditional use of external pressure. This retrospective cohort study evaluated all cases of persistent bleeding caused by penetrating neck or maxillofacial trauma received at one forward aid station between December 2009 and October 2011. Cohorts included those who were treated with Foley catheter tamponade and those managed with external pressure. Which treatment option was applied depended solely on the availability of Foley catheters at the time. The effectiveness of each technique in controlling initial and delayed hemorrhage is described, and the impact on mortality is analyzed using the Student's t test and Fisher's exact test. Seventy-seven subjects met the inclusion criteria with 42 subjects in the Foley group and 35 subjects in the external pressure group. A statistically significant difference was found between the groups regarding delayed failure, experienced by three patients (7%) in the Foley group and nine patients (26%) in the external pressure group (p < 0.05). The difference in mortality, 5% (two patients) in the Foley tamponade group and 23% (eight patients) in the external pressure group, was statistically significant (p < 0.05). For penetrating neck and maxillofacial injuries in a combat environment, Foley catheter balloon tamponade significantly reduced mortality when compared with direct pressure techniques through its effect on preventing delayed bleeding.
Large-Scale Physical Models of Thermal Remediation of DNAPL Source Zones in Aquitards
2009-05-01
pressure at the bottom of the tank. The higher pressure is reflected in higher measured water levels in external gauges . Figure 63: 3D Cross...than atmospheric. This higher pressure can raise the apparent water level in a sight gauge or external overflow and can even drive more fluid through...the water table. All met or exceeded their goals. Typical turnkey unit costs (including design, permitting, fabrication, mobilization, drilling
System Would Regulate Low Gas Pressure
NASA Technical Reports Server (NTRS)
Frazer, Robert E.
1994-01-01
System intended to maintain gases in containers at pressures near atmospheric. Includes ballast volume in form of underinflated balloon that communicates with working volume. Balloon housed in rigid chamber not subjected to extremes of temperature of working volume. Pressure in chamber surrounding balloon regulated at ambient atmospheric pressure or at constant small differential pressure above or below ambient. Expansion and contraction of balloon accommodates expansion or contraction of gas during operational heating or cooling in working volume, maintaining pressure in working volume at ambient or constant differential above or below ambient. Gas lost from system due to leakage or diffusion, low-pressure sensor responds, signaling valve actuators to supply more gas to working volume. If pressure rises too high, overpressure relief valve opens before excessive pressure damages system.
Syed, Hasson; Unnikrishnan, Vinu U; Olcmen, Semih
2016-02-01
Elevated intracranial pressure is a major contributor to morbidity and mortality in severe head injuries. Wall shear stresses in the artery can be affected by increased intracranial pressures and may lead to the formation of cerebral aneurysms. Earlier research on cerebral arteries and aneurysms involves using constant mean intracranial pressure values. Recent advancements in intracranial pressure monitoring techniques have led to measurement of the intracranial pressure waveform. By incorporating a time-varying intracranial pressure waveform in place of constant intracranial pressures in the analysis of cerebral arteries helps in understanding their effects on arterial deformation and wall shear stress. To date, such a robust computational study on the effect of increasing intracranial pressures on the cerebral arterial wall has not been attempted to the best of our knowledge. In this work, fully coupled fluid-structure interaction simulations are carried out to investigate the effect of the variation in intracranial pressure waveforms on the cerebral arterial wall. Three different time-varying intracranial pressure waveforms and three constant intracranial pressure profiles acting on the cerebral arterial wall are analyzed and compared with specified inlet velocity and outlet pressure conditions. It has been found that the arterial wall experiences deformation depending on the time-varying intracranial pressure waveforms, while the wall shear stress changes at peak systole for all the intracranial pressure profiles. © IMechE 2015.
Passive tire pressure sensor and method
Pfeifer, Kent Bryant; Williams, Robert Leslie; Waldschmidt, Robert Lee; Morgan, Catherine Hook
2006-08-29
A surface acoustic wave device includes a micro-machined pressure transducer for monitoring tire pressure. The device is configured having a micro-machined cavity that is sealed with a flexible conductive membrane. When an external tire pressure equivalent to the cavity pressure is detected, the membrane makes contact with ridges on the backside of the surface acoustic wave device. The ridges are electrically connected to conductive fingers of the device. When the detected pressure is correct, selected fingers on the device will be grounded producing patterned acoustic reflections to an impulse RF signal. When the external tire pressure is less than the cavity reference pressure, a reduced reflected signal to the receiver results. The sensor may further be constructed so as to identify itself by a unique reflected identification pulse series.
Passive tire pressure sensor and method
Pfeifer, Kent Bryant; Williams, Robert Leslie; Waldschmidt, Robert Lee; Morgan, Catherine Hook
2007-09-04
A surface acoustic wave device includes a micro-machined pressure transducer for monitoring tire pressure. The device is configured having a micro-machined cavity that is sealed with a flexible conductive membrane. When an external tire pressure equivalent to the cavity pressure is detected, the membrane makes contact with ridges on the backside of the surface acoustic wave device. The ridges are electrically connected to conductive fingers of the device. When the detected pressure is correct, selected fingers on the device will be grounded producing patterned acoustic reflections to an impulse RF signal. When the external tire pressure is less than the cavity reference pressure, a reduced reflected signal to the receiver results. The sensor may further be constructed so as to identify itself by a unique reflected identification pulse series.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gadzhaliev, M. M.; Daunov, M. I.; Musaev, A. M., E-mail: akhmed-musaev@yandex.ru
The pressure dependence of permittivity χ of direct gap ZnO, CdTe, InSb, InAs, CdSnAs{sub 2}, and CdGeAs{sub 2} semiconductors in the hydrostatic pressure range from zero to 1 GPa is determined from the results of quantitative analysis of the pressure dependences of resistivity ρ(P) and Hall constant R{sub H}(P). It is found that the dielectric constant decreases upon an increase in pressure so that coefficient (dχ/d{sub P})/χ increases with (dE{sub g}/dP)/E{sub g}.
A System to Measure Both Inner and Outer Car Tire Temperatures ``in situ''
NASA Astrophysics Data System (ADS)
Koštial, P.; Mokryšová, M.; Šišáková, J.; Mošková, Z.; Rusnáková, S.
2009-02-01
In the paper, a system for the complex analysis of the internal and external tire temperatures and pressure of sporty tires is presented. Tests were performed on the test circuit of a tire producer. The CTPA 05 measuring system (complex temperature-pressure analyzer) enables simultaneous measurements of the internal temperature and pressure in a passenger or sports tire. The experimentalist determines that the CTPA 05 can be used to measure independently the external temperature of the overcoat on the front wheel driving tires at three points. Measurements of both the internal tire temperature and pressure, as well as of the external tire temperature, are collected together with GPS (global position system) data. The system of measurement is fully automatic and contactless. The obtained results are in very good agreement with those obtained by independent methods.
1987-07-01
A forward segment is being lowered into the Transient Pressure Test Article (TPTA) test stand at the Marshall Space Flight Center (MSFC) east test area. The TPTA test stand, 14-feet wide, 27-feet long, and 33-feet high, was built in 1987 to provide data to verify the sealing capability of the redesign solid rocket motor (SRM) field and nozzle joints. The test facility applies pressure, temperature, and external loads to a short stack of solid rocket motor hardware. The simulated SRM ignition pressure and temperature transients are achieved by firing a small amount of specially configured solid propellant. The pressure transient is synchronized with external programmable dynamic loads that simulate lift off loads at the external tank attach points. Approximately one million pounds of dead weight on top of the test article simulates the weight of the other Shuttle elements.
1987-07-01
A forward segment is being lowered into the Transient Pressure Test Article (TPTA) test stand at thw Marshall Space Flight Center (MSFC) east test area. The TPTA test stand, 14-feet wide, 27-feet long, and 33-feet high, was built in 1987 to provide data to verify the sealing capability of the redesign solid rocket motor (SRM) field and nozzle joints. The test facility applies pressure, temperature, and external loads to a short stack of solid rocket motor hardware. The simulated SRM ignition pressure and temperature transients are achieved by firing a small amount of specially configured solid propellant. The pressure transient is synchronized with external programmable dynamic loads that simulate lift off loads at the external tank attach points. Approximately one million pounds of dead weight on top of the test article simulates the weight of the other Shuttle elements.
A thin-walled pressurized sphere exposed to external general corrosion and nonuniform heating
NASA Astrophysics Data System (ADS)
Sedova, Olga S.; Pronina, Yulia G.; Kuchin, Nikolai L.
2018-05-01
A thin-walled spherical shell subjected to simultaneous action of internal and external pressure, nonuniform heating and outside mechanochemical corrosion is considered. It is assumed that the shell is homogeneous, isotropic and linearly elastic. The rate of corrosion is linearly dependent on the equivalent stress, which is the sum of mechanical and temperature stress components. Paper presents a new analytical solution, which takes into account the effect of the internal and external pressure values themselves, not only their difference. At the same time, the new solution has a rather simple form as compared to the results based on the solution to the Lame problem for a thick-walled sphere under pressure. The solution obtained can serve as a benchmark for numerical analysis and for a qualitative forecast of durability of the vessel.
Chloride Fluxes in Isolated Dialyzed Barnacle Muscle Fibers
DiPolo, R.
1972-01-01
Chloride outflux and influx has been studied in single isolated muscle fibers from the giant barnacle under constant internal composition by means of a dialysis perfusion technique. Membrane potential was continually recorded. The chloride outfluxes and influxes were 143 and 144 pmoles/cm2-sec (mean resting potential: 58 mv, temperature: 22°–24°C) with internal and external chloride concentrations of 30 and 541 mM, respectively. The chloride conductance calculated from tracer measurements using constant field assumptions is about fourfold greater than that calculated from published electrical data. Replacing 97% of the external chloride ions by propionate reduces the chloride efflux by 51%. Nitrate ions applied either to the internal or external surface of the membrane slows the chloride efflux. The external pH dependence of the chloride efflux follows the external pH dependence of the membrane conductance, in the range pH 3.9–4.7, increasing with decreasing pH. In the range pH 5–9, the chloride efflux increased with increasing pH, in a manner similar to that observed in frog muscle fibers. The titration curve for internal pH changes in the range 4.0–7.0 was quantitatively much different from that for external pH change, indicating significant asymmetry in the internal and external pH dependence of the chloride efflux. PMID:5074810
NASA Astrophysics Data System (ADS)
Huveneers, François
2018-04-01
We investigate the long-time behavior of a passive particle evolving in a one-dimensional diffusive random environment, with diffusion constant D . We consider two cases: (a) The particle is pulled forward by a small external constant force and (b) there is no systematic bias. Theoretical arguments and numerical simulations provide evidence that the particle is eventually trapped by the environment. This is diagnosed in two ways: The asymptotic speed of the particle scales quadratically with the external force as it goes to zero, and the fluctuations scale diffusively in the unbiased environment, up to possible logarithmic corrections in both cases. Moreover, in the large D limit (homogenized regime), we find an important transient region giving rise to other, finite-size scalings, and we describe the crossover to the true asymptotic behavior.
Lauf, P K; Adragna, N C
1996-10-01
Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K-Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato-2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl.
1996-01-01
Swelling-induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing. This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K- Cl cotransport. The anion exchange inhibitor 4,4'diisothiocyanato- 2,2'disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3, at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal K concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl. PMID:8894982
External front instabilities induced by a shocked particle ring.
Rodriguez, V; Saurel, R; Jourdan, G; Houas, L
2014-10-01
The dispersion of a cylindrical particle ring by a blast or shock wave induces the formation of coherent structures which take the form of particle jets. A blast wave, issuing from the discharge of a planar shock wave at the exit of a conventional shock tube, is generated in the center of a granular medium ring initially confined inside a Hele-Shaw cell. With the present experimental setup, under impulsive acceleration, a solid particle-jet formation is observed in a quasi-two-dimensional configuration. The aim of the present investigation is to observe in detail the formation of very thin perturbations created around the external surface of the dispersed particle layer. By means of fast flow visualization with an appropriate recording window, we focus solely on the first instants during which the external particle ring becomes unstable. We find that the critical area of the destabilization of the external ring surface is constant regardless of the acceleration of the initial layer. Moreover, we observe in detail the external front perturbation wavelength, rendered dimensionless by the initial ring perimeter, and follow its evolution with the initial particle layer acceleration. We report this quantity to be constant regardless of the evolution of the initial particle layer acceleration. Finally, we can reasonably assert that external front perturbations depend solely on the material of the particles.
Multiphoton amplitude in a constant background field
NASA Astrophysics Data System (ADS)
Ahmad, Aftab; Ahmadiniaz, Naser; Corradini, Olindo; Kim, Sang Pyo; Schubert, Christian
2018-01-01
In this contribution, we present our recent compact master formulas for the multiphoton amplitudes of a scalar propagator in a constant background field using the worldline fomulation of quantum field theory. The constant field has been included nonperturbatively, which is crucial for strong external fields. A possible application is the scattering of photons by electrons in a strong magnetic field, a process that has been a subject of great interest since the discovery of astrophysical objects like radio pulsars, which provide evidence that magnetic fields of the order of 1012G are present in nature. The presence of a strong external field leads to a strong deviation from the classical scattering amplitudes. We explicitly work out the Compton scattering amplitude in a magnetic field, which is a process of potential relevance for astrophysics. Our final result is compact and suitable for numerical integration.
NASA Technical Reports Server (NTRS)
Parmar, D. S.; Holmes, H. K.
1993-01-01
Ferroelectric liquid crystals in a new configuration, termed partially exposed polymer dispersed ferroelectric liquid crystal (PEPDFLC), respond to external pressures and demonstrate pressure-induced electro-optic switching response. When the PEPDFLC thin film is sandwiched between two transparent conducting electrodes, one a glass plate and the other a flexible sheet such as polyvenylidene fluoride, the switching characteristics of the thin film are a function of the pressure applied to the flexible transparent electrode and the bias voltage across the electrodes. Response time measurements reveal a linear dependence of the change in electric field with external pressure.
Monte Carlo modeling the phase diagram of magnets with the Dzyaloshinskii - Moriya interaction
NASA Astrophysics Data System (ADS)
Belemuk, A. M.; Stishov, S. M.
2017-11-01
We use classical Monte Carlo calculations to model the high-pressure behavior of the phase transition in the helical magnets. We vary values of the exchange interaction constant J and the Dzyaloshinskii-Moriya interaction constant D, which is equivalent to changing spin-spin distances, as occurs in real systems under pressure. The system under study is self-similar at D / J = constant , and its properties are defined by the single variable J / T , where T is temperature. The existence of the first order phase transition critically depends on the ratio D / J . A variation of J strongly affects the phase transition temperature and width of the fluctuation region (the ;hump;) as follows from the system self-similarity. The high-pressure behavior of the spin system depends on the evolution of the interaction constants J and D on compression. Our calculations are relevant to the high pressure phase diagrams of helical magnets MnSi and Cu2OSeO3.
Schools under Pressure: The External Environment and Recent Organizational Reforms.
ERIC Educational Resources Information Center
Salganik, Laura H.
Reductions in resources and increases in external demands place schools under pressure that can be relieved to some extent by organizational changes. When resources are sufficient, these changes may take the form of technical rationality--that is, decisions concerning policy and practices are made on the basis of neutral, measurable data rather…
40 CFR 63.7741 - What are the installation, operation, and maintenance requirements for my monitors?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Pollutants for Iron and Steel Foundries Continuous Compliance Requirements § 63.7741 What are the... eliminates pulsating pressure, vibration, and internal and external corrosion. (ii) Use a gauge with a... minimizes or eliminates pulsating pressure, vibration, and internal and external corrosion. (ii) Use a gauge...
The Politics of Testing in South Africa
ERIC Educational Resources Information Center
Chisholm, Linda; Wildeman, Russell
2013-01-01
This article considers the politics of adoption of a testing regime in South Africa. While the broad features of this regime are similar to those in developed countries, there are features specific to the South African context. These emerge from a combination of external and internal pressures. External pressures derive from international testing…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diefenbacher, Jason; McKelvy, Michael; Chizmeshya, Andrew V.G.
2005-01-01
A microreactor has been developed for in situ, spectroscopic investigations of materials and reaction processes with full external pressure and temperature control from ambient conditions to 400 deg. C and 310 bar. The sample chamber is in direct contact with an external manifold, whereby gases, liquids or fluids can be injected and their activities controlled prior to and under investigation conditions. The microreactor employs high strength, single crystal moissanite windows which allow direct probe beam interaction with a sample to investigate in situ reaction processes and other materials properties. The relatively large volume of the cell, along with full opticalmore » accessibility and external temperature and pressure control, make this reaction cell well suited for experimental investigations involving any combination of gas, fluid, and solid interactions. The microreactor's capabilities are demonstrated through an in situ x-ray diffraction study of the conversion of a meta-serpentine sample to magnesite under high pressure and temperature. Serpentine is one of the mineral candidates for the implementation of mineral carbonation, an intriguing carbon sequestration candidate technology.« less
Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.
Kang, Seong Min; Her, Keun; Choi, Seong Wook
2016-08-25
In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diefenbacher, J.; McKelvy, M.; Chizemeshya, A.V.
2010-07-13
A microreactor has been developed for in situ, spectroscopic investigations of materials and reaction processes with full external pressure and temperature control from ambient conditions to 400 C and 310 bar. The sample chamber is in direct contact with an external manifold, whereby gases, liquids or fluids can be injected and their activities controlled prior to and under investigation conditions. The microreactor employs high strength, single crystal moissanite windows which allow direct probe beam interaction with a sample to investigate in situ reaction processes and other materials properties. The relatively large volume of the cell, along with full optical accessibilitymore » and external temperature and pressure control, make this reaction cell well suited for experimental investigations involving any combination of gas, fluid, and solid interactions. The microreactor's capabilities are demonstrated through an in situ x-ray diffraction study of the conversion of a meta-serpentine sample to magnesite under high pressure and temperature. Serpentine is one of the mineral candidates for the implementation of mineral carbonation, an intriguing carbon sequestration candidate technology.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahart, Muhtar; Aihaiti, Dilare; Hemley, Russell J.
The pressure dependence of the Boson peak (BP) of glycerol, including its behavior across the liquid-glass transition, has been studied under pressure using Raman scattering. A significant increase of the BP frequency was observed with pressure up to 11 GPa at room temperature. The pressure dependence of BP frequency ν BP is proportional to (1+P/P 0) 1/3, where P and P 0 are the pressure and a constant, respectively, the spectra are consistent with a soft potential model. The characteristic length of medium range order is close in size to a cyclic trimer of glycerol molecules, which is predicted asmore » the medium range order of a BP vibration using molecular dynamics simulations. The pressure dependence of a characteristic length of medium range order is nearly constant. The pressure induced structural changes in glycerol can be understood in terms of the shrinkage of voids with cyclic trimers remaining up to at least 11 GPa. Lastly, the pressure dependence of intermolecular O-H stretching mode indicates that the intermolecular hydrogen bond distance gradually decreases below the glass transition pressure of ~5 GPa, while it becomes nearly constant in the glassy state indicating the disappearance of the free volume in the dense glass.« less
Biofeedback defaecation training for anismus.
Lestàr, B; Penninckx, F; Kerremans, R
1991-11-01
Anismus, paradoxical external sphincter function, spastic pelvic floor syndrome, rectoanal dysnergia, abdomino-levator incoordination for abdominopelvic asychronism, are all due to paradoxical contraction of the striated sphincter apparatus during voiding and is characterised by prolonged and excessive straining at stool. Biofeedback is the treatment of choice and has to be introduced at an early stage. We present the results of an ambulatory approach based on the integration of simulated balloon defaecation with small (50 ml) as well as constant rectal sensation volume, defaecometry and anal manometry. The pathophysiology visualised by the patient's own anorectal pressure recordings on the screen of a personal computer is explained and corrected. Sixteen patients were treated and followed for at least 1 year. Manometric data were normal except for an increased minimum residual pressure and rectal compliance. Nine patients could not evacuate a 50 ml bolus initially. Simulated defaecation became possible in seven out of these nine patients when the bolus was increased up to the individual constant rectal sensation volume. Two patients could not evacuate this volume either, while defaecation was made much less laborious in the other seven patients. Paradoxical contraction was immediately corrected in 7/16 cases. Also, as an immediate, objective benefit of a single training session, improved defaecation of a 50 ml bolus was observed in 11 patients. This effect was preserved after 6 weeks in nine cases; symptomatic recurrence did not occur in these patients during follow-up. This method of defaecation training has many advantages as compared with sphincter training using EMG electrodes eventually performed in the absence of a desire to defaecate or in lying position.(ABSTRACT TRUNCATED AT 250 WORDS)
Viscous Creep in Dry Unconsolidated Gulf of Mexico Shale
NASA Astrophysics Data System (ADS)
Chang, C.; Zoback, M. D.
2002-12-01
We conducted laboratory experiments to investigate creep characteristics of dry unconsolidated shale recovered from the pathfinder well, Gulf of Mexico (GOM). We subjected jacketed cylindrical specimens (25.4 mm diameter) to hydrostatic pressure that increased from 10 to 50 MPa in steps of 5 MPa. We kept the pressure constant in each step for at least 6 hours and measured axial and lateral strains (provided by LVDTs) and ultrasonic velocities (provided by seismic-wave transducers). The dry shale exhibited pronounced creep strain at all pressure levels, indicating that the dry frame of the shale possesses an intrinsic viscous property. Interestingly, the creep behavior of the shale is different above and below 30 MPa confining pressure. Above 30 MPa, the amount of creep strain in 6 hours is nearly constant with equal pressurization steps, indicating a linear viscous rheology. Below 30 MPa, the amount of creep increases linearly as pressure is raised in constant incremental steps, suggesting that the creep deformation accelerates as pressure increases within this pressure range. Thus, the general creep behavior of the GOM shale is characterized by a bilinear dependence on pressure magnitude. This creep characteristic is quite different from that observed in unconsolidated reservoir sands (Hagin and Zoback, 2002), which exhibited nearly constant amount of creep regardless of the pressure magnitude for equal increasing steps of pressure. The shale exhibits a lack of creep (and nearly negligible strain recovery) when unloaded, suggesting that the creep strain is irrecoverable and can be considered viscoplastic deformation. SEM observations show that the major mechanism of compaction of the dry shale appears to be packing of clay and a progressive collapse of pore (void) spaces. Creep compaction is considerably more significant than compaction that occurs instantaneously, indicating that the process of shale compaction is largely time-dependent.
Kinetic analysis of volatile formation in milk subjected to pressure-assisted thermal treatments.
Vazquez-Landaverde, P A; Qian, M C; Torres, J A
2007-09-01
Volatile formation in milk subjected to pressure-assisted thermal processing (PATP) was investigated from a reaction kinetic analysis point of view to illustrate the advantages of this technology. The concentration of 27 volatiles of different chemical class in milk subjected to pressure, temperature, and time treatments was fitted to zero-, 1st-, and 2nd-order chemical reaction models. Temperature and pressure effects on rate constants were analyzed to obtain activation energy (E(a)) and activation volume (deltaV*) values. Hexanal, heptanal, octanal, nonanal, and decanal followed 1st-order kinetics with rate constants characterized by E(a) values decreasing with pressure reflecting negative deltaV* values. Formation of 2-methylpropanal, 2,3-butanedione, and hydrogen sulfide followed zero-order kinetics with rate constants increasing with temperature but with unclear pressure effects. E(a) values for 2-methylpropanal and 2,3-butanedione increased with pressure, that is, deltaV* > 0, whereas values for hydrogen sulfide remained constant, that is, deltaV* = 0. The concentration of all other volatiles, including methanethiol, remained unchanged in pressure-treated samples, suggesting large negative deltaV* values. The concentration of methyl ketones, including 2-pentanone, 2-hexanone, 2-heptanone, 2-octanone, 2-nonanone, 2-decanone, and 2-undecanone, was independent of pressure and pressure-holding time. PATP promoted the formation of few compounds, had no effect on some, and inhibited the formation of volatiles reported to be factors of the consumer rejection of "cooked" milk flavor. The kinetic behavior observed suggested that new reaction formation mechanisms were not likely involved in volatile formation in PATP milk. The application of the Le Chatelier principle frequently used to explain the high quality of pressure-treated foods, often with no supporting experimental evidence, was not necessary.
NASA Astrophysics Data System (ADS)
Escamilla, R.; Carvajal, E.; Cruz-Irisson, M.; Romero, M.; Gómez, R.; Marquina, V.; Galván, D. H.; Durán, A.
2016-12-01
The structural, elastic, vibrational, thermodynamic and electronic properties of the Mo2B intermetallic under pressure are assessed using first-principles calculations based on the generalized gradient approximation (GGA) proposed by Perdew-Wang (PW91). Our results show that the calculated structural parameters at a pressure of zero GPa are in good agreement with the available experimental data. The effect of high pressures on the lattice constants shows that the compression along the c-axis and along the a-axis are similar. The elastic constants were calculated using the static finite strain technique, and the bulk shear moduli are derived from the ideal polycrystalline aggregate. We find that the elastic constants, elastic modulus and hardness monotonically increase as a function of pressure; consequently, the structure is dynamically stable and tends from brittle to ductile behavior under pressure. The Debye temperature θD increases and the so-called Gru¨ neisen constant γ decreases due to stiffening of the crystal structure. The phonon dispersion curves were obtained using the direct method. Additionally, the internal energy (ΔE), the Helmholtz free energy (ΔF), the entropy (S) and the lattice contribution to the heat capacity Cv were calculated and analyzed with the help of the phonon dispersion curves. The N(EF) and the electron transfer between the B and Mo atoms increase as a function of pressure.
Aggarwal, A. K.; Sharma, Richa; Sharma, Sanjeev
2014-01-01
The objective of this paper is to provide guidance for the design of the thick-walled cylinder made up of transversely isotropic material so that collapse of cylinder due to influence of internal and external pressure can be avoided. The concept of transition theory based on Lebesgue strain measure has been used to simplify the constitutive equations. Results have been analyzed theoretically and discussed numerically. From this analysis, it has been concluded that, under the influence of internal and external pressure, circular cylinder made up of transversely isotropic material (beryl) is on the safer side of the design as compared to the cylinders made up of isotropic material (steel). This is because of the reason that percentage increase in effective pressure required for initial yielding to become fully plastic is high for beryl as compared to steel which leads to the idea of “stress saving” that reduces the possibility of collapse of thick-walled cylinder due to internal and external pressure. PMID:24523632
NASA Technical Reports Server (NTRS)
Weber, L. A.
1975-01-01
Compressibility measurements and thermodynamic properties data for parahydrogen were extended to higher temperatures and pressures. Results of an experimental program are presented in the form of new pressure, volume and temperature data in the temperature range 23 to 300 K at pressures up to 800 bar. Also given are tables of thermodynamic properties on isobars to 1000 bar including density, internal energy, enthalpy, entropy, specific heats at constant volume and constant pressure, velocity of sound, and surface derivatives. The accuracy of the data is discussed and comparisons are made with previous data.
Transient Behavior of Lumped-Constant Systems for Sensing Gas Pressures
NASA Technical Reports Server (NTRS)
Delio, Gene J; Schwent, Glennon V; Cesaro, Richard S
1949-01-01
The development of theoretical equations describing the behavior of a lumped-constant pressure-sensing system under transient operation Is presented with experimental data that show agreement with the equations. A pressure-sensing system 'consisting of a tube terminating in a reservoir is investigated for the transient relation between a presSure disturbance at the open end of the tube and the pressure response in the reservoir. Design parameters are presented that can be adjusted to achieve a desired performance fran such a system when the system is considered as a transfer member of a control loop.
NASA Astrophysics Data System (ADS)
Novak, Charles W.
1982-02-01
In this, the International Year of the Disabled, attention is directed among other areas toward rehabilitation and sports participation of wheelchair users. As an application of movement analysis in medicine and rehabilitation and as an application of sports research using biomechanics, this investigation was performed to compare the results of two methods of gathering data on the stress of wheelchair propelling at equivalent work loads and to account for differences in physiological responses with a mechanical analysis of wheelchair propelling. Physiological data collected were heart rate, systolic blood pressure, and rate-pressure product. A biomechanical cinematography analysis was used to determine external work in wheelchair propelling and to determine the extent to which modifications in segment actionsoccurred during increasing magnitude of work. A cycle ergometer was adjusted to replicate external work loads performed during wheelchair propelling. A t-test of equivalent external work loads indicated that heart rate was not different between the two exercise modes at the .05 level of significance. The t-test did indicate a significant difference in systolic blood pressure and rate-pressure product at the .05 level of significance. The biomechanical analysis of wheelchair propelling established that an increase in external work was accomplished by a decrease in the range of motion and an increase in the speed of movement. During cycle ergometry the range and speed of movement remained the same while resistance was increased. Results of the study established that while heart rate for equivalent external work loads was the same for wheelchair propelling and arm cranking cycle ergometry, systolic blood pressure and rate-pressure product were not the same. The suggestion was that some means of propelling a wheelchair other than that which is con-sidered "standard" might be considered which produces less stressful responses in wheelchair users.
Chen, Chih-Chung; Johnson, Mark I
2009-10-01
Frequency-modulated transcutaneous electrical nerve stimulation (TENS) delivers currents that fluctuate between preset boundaries over a fixed period of time. This study compared the effects of constant-frequency TENS and frequency-modulated TENS on blunt pressure pain in healthy human volunteers. Thirty-six participants received constant-frequency TENS (80 pps), frequency-modulated TENS (20 to 100 pps), and placebo (no current) TENS at a strong nonpainful intensity in a randomized cross-over manner. Pain threshold was taken from the forearm using pressure algometry. There were no statistical differences between constant-frequency TENS and frequency-modulated TENS after 20 minutes (OR = 1.54; CI, 0.29, 8.23, P = 1.0). Both constant-frequency TENS and frequency-modulated TENS were superior to placebo TENS (OR = 59.5, P < .001 and OR = 38.5, P < .001, respectively). Frequency-modulated TENS does not influence hypoalgesia to any greater extent than constant-frequency TENS when currents generate a strong nonpainful paraesthesia at the site of pain. The finding that frequency-modulated TENS and constant-frequency TENS were superior to placebo TENS provides further evidence that a strong yet nonpainful TENS intensity is a prerequisite for hypoalgesia. This study provides evidence that TENS, delivered at a strong nonpainful intensity, increases pain threshold to pressure algometry in healthy participants over and above that seen with placebo (no current) TENS. Frequency-modulated TENS does not increase hypoalgesia to any appreciable extent to that seen with constant-frequency TENS.
Extra compressibility terms for Favre-averaged two-equation models of inhomogeneous turbulent flows
NASA Technical Reports Server (NTRS)
Rubesin, Morris W.
1990-01-01
Forms of extra-compressibility terms that result from use of Favre averaging of the turbulence transport equations for kinetic energy and dissipation are derived. These forms introduce three new modeling constants, a polytropic coefficient that defines the interrelationships of the pressure, density, and enthalpy fluctuations and two constants in the dissipation equation that account for the non-zero pressure-dilitation and mean pressure gradients.
Pressure Roller For Tape-Lift Tests
NASA Technical Reports Server (NTRS)
Abrams, Eve
1991-01-01
Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.
Method and apparatus for providing a precise amount of gas at a precise humidity
Hallman, Jr., Russell L.; Truett, James C.
2001-02-06
A fluid transfer system includes a permeable fluid carrier, a constant temperature source of a first fluid, and a constant pressure source of a second fluid. The fluid carrier has a length, an inlet end, and an outlet end. The constant pressure source connects to the inlet end and communicates the second fluid into the fluid carrier, and the constant temperature source surrounds a least of portion of the length. A mixture of the first fluid and the second fluid exits via the outlet end A method of making a mixture of two fluids is also disclosed.
Production of ZrC Matrix for Use in Gas Fast Reactor Composite Fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasudevamurthy, Gokul; Knight, Travis W.; Roberts, Elwyn
2007-07-01
Zirconium carbide is being considered as a candidate for inert matrix material in composite nuclear fuel for Gas fast reactors due to its favorable characteristics. ZrC can be produced by the direct reaction of pure zirconium and graphite powders. Such a reaction is exothermic in nature. The reaction is self sustaining once initial ignition has been achieved. The heat released during the reaction is high enough to complete the reaction and achieve partial sintering without any external pressure applied. External heat source is required to achieve ignition of the reactants and maintain the temperature close to the adiabatic temperature tomore » achieve higher levels of sintering. External pressure is also a driving force for sintering. In the experiments described, cylindrical compacts of ZrC were produced by direct combustion reaction. External induction heating combined with varying amounts of external applied pressure was employed to achieve varying degrees of density/porosity. The effect of reactant particle size on the product characteristics was also studied. The samples were characterized for density/porosity, composition and microstructure. (authors)« less
High temperature aqueous stress corrosion testing device
Bornstein, A.N.; Indig, M.E.
1975-12-01
A description is given of a device for stressing tensile samples contained within a high temperature, high pressure aqueous environment, thereby permitting determination of stress corrosion susceptibility of materials in a simple way. The stressing device couples an external piston to an internal tensile sample via a pull rod, with stresses being applied to the sample by pressurizing the piston. The device contains a fitting/seal arrangement including Teflon and weld seals which allow sealing of the internal system pressure and the external piston pressure. The fitting/seal arrangement allows free movement of the pull rod and the piston.
Measurement of the Density of Base Fluids at Pressures 0.422 to 2.20 Gpa
NASA Technical Reports Server (NTRS)
Hamrock, B. J.; Jacobson, B. O.; Bergstroem, S. I.
1985-01-01
The influence of pressure on the density of six base fluids is experimentally studied for a range of pressures from 0.422 to 2.20 GPa. An important parameter used to describe the results is the change in relative volume with change in pressure dv sub r/dp. For pressures less than the solidification pressure (p ps) a small change in pressure results in a large change in dv sub r/ps. For pressures greater than the solidification pressure (p ps) there is no change in dv sub r/dp with changing pressure. The solidification pressures of the base fluids varies considerably, as do the slopes that the experimental data assumes for p ps. A new formula is developed that describes the effect of pressure on density in terms of four constants. These constants vary for the different base fluids tested.
Molecular Dynamics Evaluation of Dielectric-Constant Mixing Rules for H2O-CO2 at Geologic Conditions
Mountain, Raymond D.; Harvey, Allan H.
2015-01-01
Modeling of mineral reaction equilibria and aqueous-phase speciation of C-O-H fluids requires the dielectric constant of the fluid mixture, which is not known from experiment and is typically estimated by some rule for mixing pure-component values. In order to evaluate different proposed mixing rules, we use molecular dynamics simulation to calculate the dielectric constant of a model H2O–CO2 mixture at temperatures of 700 K and 1000 K at pressures up to 3 GPa. We find that theoretically based mixing rules that depend on combining the molar polarizations of the pure fluids systematically overestimate the dielectric constant of the mixture, as would be expected for mixtures of nonpolar and strongly polar components. The commonly used semiempirical mixing rule due to Looyenga works well for this system at the lower pressures studied, but somewhat underestimates the dielectric constant at higher pressures and densities, especially at the water-rich end of the composition range. PMID:26664009
Mountain, Raymond D; Harvey, Allan H
2015-10-01
Modeling of mineral reaction equilibria and aqueous-phase speciation of C-O-H fluids requires the dielectric constant of the fluid mixture, which is not known from experiment and is typically estimated by some rule for mixing pure-component values. In order to evaluate different proposed mixing rules, we use molecular dynamics simulation to calculate the dielectric constant of a model H 2 O-CO 2 mixture at temperatures of 700 K and 1000 K at pressures up to 3 GPa. We find that theoretically based mixing rules that depend on combining the molar polarizations of the pure fluids systematically overestimate the dielectric constant of the mixture, as would be expected for mixtures of nonpolar and strongly polar components. The commonly used semiempirical mixing rule due to Looyenga works well for this system at the lower pressures studied, but somewhat underestimates the dielectric constant at higher pressures and densities, especially at the water-rich end of the composition range.
Effects of external stream flow and afterbody variations on the performance of a plug nozzle
NASA Technical Reports Server (NTRS)
Salmi, R J; Cortright, E M , Jr
1956-01-01
The off-design operation of an isentropic plug nozzle designed for a jet pressure ratio of 15 was investigated experimentally at subsonic Mach numbers up to 0.9 and jet pressure ratios up to 5. When installed in a cylindrical nacelle with a sharp turn at the nozzle lip, the interaction of the jet and the external stream produced low pressures on the base formed by the high lip angle. These low pressures increased the nacelle drag and caused an overexpansion of the jet, which resulted in lower pressures on the plug and, hence, reduced thrust. With a boattail ahead of the plug nozzle, the base pressures were increased and the jet overexpansion significantly reduced.
Ceramic pressure housing with metal endcaps
Downing, Jr., John P.; DeRoos, Bradley G.; Hackman, Donald J.
1995-01-01
A housing for the containment of instrumentation in a high pressure fluid environment that consists of a metallic endcap and ceramic cylinder bonded together. The improvement comprises a structure which results in the improved sealing of said housing as the fluid pressure increases. The cylindrical ceramic tube and endcap are dimensioned such that mechanical failure does not occur when exposed to the desired external operating pressures which includes up to 36,000 feet of water. The housing is designed to withstand the external operating pressures without being subject to mechanical failure or excessive deformation which results in the loss of pressure housing integrity via cracking or deformation of the ceramic tube, deformation of the endcap, or from failure of the bonding agent.
Ceramic pressure housing with metal endcaps
Downing, J.P. Jr.; DeRoos, B.G.; Hackman, D.J.
1995-06-27
A housing is disclosed for the containment of instrumentation in a high pressure fluid environment that consists of a metallic endcap and ceramic cylinder bonded together. The improvement comprises a structure which results in the improved sealing of said housing as the fluid pressure increases. The cylindrical ceramic tube and endcap are dimensioned such that mechanical failure does not occur when exposed to the desired external operating pressures which includes up to 36,000 feet of water. The housing is designed to withstand the external operating pressures without being subject to mechanical failure or excessive deformation which results in the loss of pressure housing integrity via cracking or deformation of the ceramic tube, deformation of the endcap, or from failure of the bonding agent. 9 figs.
van Meegdenburg, Maxime M; Trzpis, Monika; Heineman, Erik; Broens, Paul M A
2016-09-01
Chronic anal fissure is a painful disorder caused by linear ulcers in the distal anal mucosa. Even though it counts as one of the most common benign anorectal disorders, its precise etiology and pathophysiology remains unclear. Current thinking is that anal fissures are caused by anal trauma and pain, which leads to internal anal sphincter hypertonia. Increased anal basal pressure leads to diminished anodermal blood flow and local ischemia, which delays healing and leads to chronic anal fissure. The current treatment of choice for chronic anal fissure is either lateral internal sphincterotomy or botulinum toxin injections. In contrast to current thinking, we hypothesize that the external, rather than the internal, anal sphincter is responsible for increased anal basal pressure in patients suffering from chronic anal fissure. We think that damage to the anal mucosa leads to hypersensitivity of the contact receptors of the anal-external sphincter continence reflex, resulting in overreaction of the reflex. Overreaction causes spasm of the external anal sphincter. This in turn leads to increased anal basal pressure, diminished anodermal blood flow, and ischemia. Ischemia, finally, prevents the anal fissure from healing. Our hypothesis is supported by two findings. The first concerned a chronic anal fissure patient with increased anal basal pressure (170mmHg) who had undergone lateral sphincterotomy. Directly after the operation, while the submucosal anesthetic was still active, basal anal pressure decreased to 80mmHg. Seven hours after the operation, when the anesthetic had completely worn off, basal anal pressure increased again to 125mmHg, even though the internal anal sphincter could no longer be responsible for the increase. Second, in contrast to previous studies, recent studies demonstrated that botulinum toxin influences external anal sphincter activity and, because it is a striated muscle relaxant, it seems reasonable to presume that it affects the striated external anal sphincter, rather than the smooth internal anal sphincter. If our hypothesis is proved correct, the treatment option of lateral internal sphincterotomy should be abandoned in patients suffering from chronic anal fissures, since it fails to eliminate the cause of high anal basal pressure. Additionally, lateral internal sphincterotomy may cause damage to the anal-external sphincter continence reflex, resulting in fecal incontinence. Instead, higher doses of botulinum toxin should be administered to those patients suffering from chronic anal fissure who appeared unresponsive to lower doses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pressure Dependence of the Boson Peak of Glassy Glycerol
Ahart, Muhtar; Aihaiti, Dilare; Hemley, Russell J.; ...
2017-05-31
The pressure dependence of the Boson peak (BP) of glycerol, including its behavior across the liquid-glass transition, has been studied under pressure using Raman scattering. A significant increase of the BP frequency was observed with pressure up to 11 GPa at room temperature. The pressure dependence of BP frequency ν BP is proportional to (1+P/P 0) 1/3, where P and P 0 are the pressure and a constant, respectively, the spectra are consistent with a soft potential model. The characteristic length of medium range order is close in size to a cyclic trimer of glycerol molecules, which is predicted asmore » the medium range order of a BP vibration using molecular dynamics simulations. The pressure dependence of a characteristic length of medium range order is nearly constant. The pressure induced structural changes in glycerol can be understood in terms of the shrinkage of voids with cyclic trimers remaining up to at least 11 GPa. Lastly, the pressure dependence of intermolecular O-H stretching mode indicates that the intermolecular hydrogen bond distance gradually decreases below the glass transition pressure of ~5 GPa, while it becomes nearly constant in the glassy state indicating the disappearance of the free volume in the dense glass.« less
Redistribution of oxygen ions in single crystal YBa2Cu3O7-x owing to external hydrostatic pressure
NASA Astrophysics Data System (ADS)
Boiko, Yu. I.; Bogdanov, V. V.; Vovk, R. V.; Khadzhai, G. Ya.; Savich, S. V.
2018-01-01
The effect of high hydrostatic pressure on the temperature dependences of the electrical resistance in the basal plane of single crystal YBa2Cu3O7-x with an oxygen deficit is studied. It is found that an external hydrostatic pressure P ≈ 7 kbar substantially intensifies the diffusive coalescence of oxygen clusters, i.e., causes an increase in their average size. This, in turn, produces an increased number of negative U-centers whose presence leads to the appearance of a phase capable of generating paired carriers of electrical charge and is, therefore, characterized by a higher transition temperature Tc. Changes in the form of the temperature and time dependences of the electrical resistivity under external hydrostatic pressure are discussed in terms of this same hypothesis regarding the mechanism of diffusive coalescence of oxygen clusters.
Pressure dependence of the absolute rate constant for the reaction OH + C2H2 from 228 to 413K
NASA Technical Reports Server (NTRS)
Michael, J. V.; Nava, D. F.; Borokowski, R. P.; Payne, W. A.; Stief, L. J.
1980-01-01
The pressure dependence of absolute rate constants for the reaction of OH + C2H2 yields products has been examined at five temperatures ranging from 228 to 413 K. The experimental techniques which was used is flash photolysis-resonance fluoresence. OH was produced by water photolysis and hydroxyl resonance fluorescent photons were measured by multiscaling techniques. The results indicate that the low pressure bimolecular rate constant is 4 x 10 the the minus 13th power cu cm molecule (-1) s(-1) over the temperature range studied. A substantial increase in the bimolecular rate constant with an increase in pressure was observed at all temperatures except 228 K. This indicates the importance of initial adduct formation and subsequent stablization. The high pressure results are well represented by the Arrhenius expression (k sub bi) sub infinity = (6.83 + or - 1.19) x 10 to the minus 12th power exp(-646 + or - 47/T)cu cm molecule (-1) s(-1). The results are compared to previous investigated and are theoretically discussed. The implications of these results on modeling of terrestrial and planetary atmospheres and also in combustion chemistry are discussed.
Capillary-Physics Mechanism of Elastic-Wave Mobilization of Residual Oil
NASA Astrophysics Data System (ADS)
Beresnev, I. A.; Pennington, W. D.; Turpening, R. M.
2003-12-01
Much attention has been given to the possibility of vibratory mobilization of residual oil as a method of enhanced recovery. The common features of the relevant applications have nonetheless been inconsistency in the results of field tests and the lack of understanding of a physical mechanism that would explain variable experiences. Such a mechanism can be found in the physics of capillary trapping of oil ganglia, driven through the pore channels by an external pressure gradient. Entrapping of ganglia occurs due to the capillary pressure building on the downstream meniscus entering a narrow pore throat. The resulting internal-pressure imbalance acts against the external gradient, which needs to exceed a certain threshold to carry the ganglion through. The ganglion flow thus exhibits the properties of the Bingham (yield-stress) flow, not the Darcy flow. The application of vibrations is equivalent to the addition of an oscillatory forcing to the constant gradient. When this extra forcing acts along the gradient, an instant "unplugging" occurs, while, when the vibration reverses direction, the flow is plugged. This asymmetry results in an average non-zero flow over one period of vibration, which explains the mobilization effect. The minimum-amplitude and maximum-frequency thresholds apply for the mobilization to occur. When the vibration amplitude exceeds a certain "saturation" level, the flow returns to the Darcy regime. The criterion of the mobilization of a particular ganglion involves the parameters of both the medium (pore geometry, interfacial and wetting properties, fluid viscosity) and the oscillatory field (amplitude and frequency). The medium parameters vary widely under natural conditions. It follows that an elastic wave with a given amplitude and frequency will always produce a certain mobilization effect, mobilizing some ganglia and leaving others intact. The exact macroscopic effect is hard to predict, as it will represent a response of the populations of ganglia with unknown parameter distributions. The variability of responses to vibratory stimulation should thus be expected.
Perceptions of selected science careers by African American high school males
NASA Astrophysics Data System (ADS)
Ijames, Erika Denise
Research indicates that internal and external factors such as role models, stereotypes, and pressures placed on African American males by their family and friends influence their perceptions of science careers (Assibey-Mensah, 1997; Hess & Leal, 1997; Jacobowitz, 1983; Maple & Stage, 1991; Thomas, 1989; Ware & Lee, 1988). The purpose of this research was to investigate the perceptions of African American high school males about selected science careers based on apparent internal and external factors. Two questions guided this research: (1) What are high school African American males' perceptions of science careers? (2) What influences high school African American males' perceptions of science careers? This research was based on a pilot study in which African American college males perceived a selection of science careers along racial and gender lines. The follow-up investigation was conducted at Rockriver High School in Acorn County, and the participants were three college-bound African American males. The decision to choose males was based on the concept of occupational niching along gender lines. In biology, niching is defined as the role of a particular species regarding space and reproduction, and its interactions with other factors. During the seven-week period of the students' senior year, they met with the researcher to discuss their perceptions of science careers. An ethnographic approach was used to allow a richer and thicker narrative to occur. Critical theory was used to describe and interpret the voices of the participants from a social perspective. The data collected were analyzed using a constant comparative analysis technique. The participants revealed role models, negative stereotypes, peer pressure, social pressures, and misconceptions as some of the factors that influenced their perceptions of science careers. Results of this research suggest that by dispelling the misconceptions, educators can positively influence the attitudes and perceptions of their students about science careers and possibly increase the number of African American men as well as other minorities currently underrepresented in some science careers.
Structural Influence of Dynamics of Bottom Loads
2014-02-10
using the Numerette research craft, are underway. Early analytic research on slamming was done by von Karman [5] using a momentum approach, and by...pressure q{x,t) as two constant pressures, qi and qj, traveling at a constant speed c. Using the Euler- Bernoulli beam assumptions the governing
Distillation device supplies cesium vapor at constant pressure
NASA Technical Reports Server (NTRS)
Basiulis, A.; Shefsiek, P. K.
1968-01-01
Distillation apparatus in the form of a U tube supplies small amounts of pure cesium vapor at constant pressure to a thermionic converter. The upstream leg of the U tube is connected to a vacuum pump to withdraw noncondensable impurities, the bottom portion serves as a reservoir for the liquid cesium.
Therapeutic Ultrasound Enhancement of Drug Delivery to Soft Tissues
NASA Astrophysics Data System (ADS)
Lewis, George; Wang, Peng; Lewis, George; Olbricht, William
2009-04-01
Effects of exposure to 1.58 MHz focused ultrasound on transport of Evans Blue Dye (EBD) in soft tissues are investigated when an external pressure gradient is applied to induce convective flow through the tissue. The magnitude of the external pressure gradient is chosen to simulate conditions in brain parenchyma during convection-enhanced drug delivery (CED) to the brain. EBD uptake and transport are measured in equine brain, avian muscle and agarose brain-mimicking phantoms. Results show that ultrasound enhances EBD uptake and transport, and the greatest enhancement occurs when the external pressure gradient is applied. The results suggest that exposure of the brain parenchyma to ultrasound could enhance penetration of material infused into the brain during CED therapy.
Fikru, Mahelet G
2014-11-01
This paper examines the different internal and external institutional factors that affect the decision of businesses in developing countries to adopt international certification (IC). Past studies focus on pressure from international laws, the role of multinationals, and businesses mimicking practices of their counterparts in developed countries. This paper finds that, in addition to these external factors, internal factors may have a significant role. Even though environmental regulation is weak in developing countries, governments do not ignore industrial pollution and casualties. They respond by increasing bureaucratic regulations for businesses and this can affect the decision to adopt IC. Furthermore, internal pressure may come from workers' unions that push for a safe and healthy working environment. Published by Elsevier Ltd.
Mizuno, Ju; Namba, Chikara; Takahashi, Toru
2014-10-01
We investigated external pressure on peroneal nerve tract coming in contact with two kinds of leg holders using pressure distribution measurement system BIG- MAT® (Nitta Corp., Osaka) in the lithotomy position Peak contact (active) pressure at the left fibular head region coming in contact with knee-crutch-type leg holder M® (Takara Belmont Corp., Osaka), which supports the left popliteal fossa, was 78.0 ± 26.4 mmHg. On the other hand, peak contact pressure at the left lateral lower leg region coming in contact with boot-support-type leg holder Bel Flex® (Takara Belmont Corp., Osaka), which supports the left lower leg and foot was 26.3±7.9 mmHg. These results suggest that use of knee-crutch-type leg holder is more likely to induce common peroneal nerve palsy at the fibular head region, but use of boot-support-type leg holder dose not easily induce superficial peroneal nerve palsy at the lateral lower leg region, because capillary blood pressure is known to be 32 mmHg. Safer holders for positioning will be developed to prevent nerve palsy based on the analysis of chronological change in external pressure using BIG-MAT® system during anesthesia.
Skin friction under pressure. The role of micromechanics
NASA Astrophysics Data System (ADS)
Leyva-Mendivil, Maria F.; Lengiewicz, Jakub; Limbert, Georges
2018-03-01
The role of contact pressure on skin friction has been documented in multiple experimental studies. Skin friction significantly raises in the low-pressure regime as load increases while, after a critical pressure value is reached, the coefficient of friction of skin against an external surface becomes mostly insensitive to contact pressure. However, up to now, no study has elucidated the qualitative and quantitative nature of the interplay between contact pressure, the material and microstructural properties of the skin, the size of an indenting slider and the resulting measured macroscopic coefficient of friction. A mechanistic understanding of these aspects is essential for guiding the rational design of products intended to interact with the skin through optimally-tuned surface and/or microstructural properties. Here, an anatomically-realistic 2D multi-layer finite element model of the skin was embedded within a computational contact homogenisation procedure. The main objective was to investigate the sensitivity of macroscopic skin friction to the parameters discussed above, in addition to the local (i.e. microscopic) coefficient of friction defined at skin asperity level. This was accomplished via the design of a large-scale computational experiment featuring 312 analyses. Results confirmed the potentially major role of finite deformations of skin asperities on the resulting macroscopic friction. This effect was shown to be modulated by the level of contact pressure and relative size of skin surface asperities compared to those of a rigid slider. The numerical study also corroborated experimental observations concerning the existence of two contact pressure regimes where macroscopic friction steeply and non-linearly increases up to a critical value, and then remains approximately constant as pressure increases further. The proposed computational modelling platform offers attractive features which are beyond the reach of current analytical models of skin friction, namely, the ability to accommodate arbitrary kinematics, non-linear constitutive properties and the complex skin microstructure.
Numerical Modeling of Cavitating Venturi: A Flow Control Element of Propulsion System
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Saxon, Jeff (Technical Monitor)
2002-01-01
In a propulsion system, the propellant flow and mixture ratio could be controlled either by variable area flow control valves or by passive flow control elements such as cavitating venturies. Cavitating venturies maintain constant propellant flowrate for fixed inlet conditions (pressure and temperature) and wide range of outlet pressures, thereby maintain constant, engine thrust and mixture ratio. The flowrate through the venturi reaches a constant value and becomes independent of outlet pressure when the pressure at throat becomes equal to vapor pressure. In order to develop a numerical model of propulsion system, it is necessary to model cavitating venturies in propellant feed systems. This paper presents a finite volume model of flow network of a cavitating venturi. The venturi was discretized into a number of control volumes and mass, momentum and energy conservation equations in each control volume are simultaneously solved to calculate one-dimensional pressure, density, and flowrate and temperature distribution. The numerical model predicts cavitations at the throat when outlet pressure was gradually reduced. Once cavitation starts, with further reduction of downstream pressure, no change in flowrate is found. The numerical predictions have been compared with test data and empirical equation based on Bernoulli's equation.
Aqueous Humor Dynamics of the Brown-Norway Rat
Ficarrotta, Kayla R.; Bello, Simon A.; Mohamed, Youssef H.; Passaglia, Christopher L.
2018-01-01
Purpose The study aimed to provide a quantitative description of aqueous humor dynamics in healthy rat eyes. Methods One eye of 26 anesthetized adult Brown-Norway rats was cannulated with a needle connected to a perfusion pump and pressure transducer. Pressure-flow data were measured in live and dead eyes by varying pump rate (constant-flow technique) or by modulating pump duty cycle to hold intraocular pressure (IOP) at set levels (modified constant-pressure technique). Data were fit by the Goldmann equation to estimate conventional outflow facility (\\begin{document}\
Spin-oscillator model for the unzipping of biomolecules by mechanical force.
Prados, A; Carpio, A; Bonilla, L L
2012-08-01
A spin-oscillator system models unzipping of biomolecules (such as DNA, RNA, or proteins) subject to an external force. The system comprises a macroscopic degree of freedom, represented by a one-dimensional oscillator, and internal degrees of freedom, represented by Glauber spins with nearest-neighbor interaction and a coupling constant proportional to the oscillator position. At a critical value F(c) of an applied external force F, the oscillator rest position (order parameter) changes abruptly and the system undergoes a first-order phase transition. When the external force is cycled at different rates, the extension given by the oscillator position exhibits a hysteresis cycle at high loading rates, whereas it moves reversibly over the equilibrium force-extension curve at very low loading rates. Under constant force, the logarithm of the residence time at the stable and metastable oscillator rest position is proportional to F-F(c) as in an Arrhenius law.
Rock Deformation at High Confining Pressure and Temperature.
debugged, delivered and installed to the contracting agency. Clay specimens of illite, kaolinite and montmorillonite were deformed in tri-axial compression...at 25 and 3000C at a constant confining pressure of 2 kb and a constant strain rate of .0001 sec. The illite and kaolinite are stronger under these...conditions than montmorillonite . Cores from dolomite single crystals were deformed at a confining pressure of 7 kb and temperatures of 300 and 500C
Reduction of dissipation in a thermal engine by means of periodic changes of external constraintsa)
NASA Astrophysics Data System (ADS)
Escher, Claus; Ross, John
1985-03-01
We consider a thermal engine driven by chemical reactions, which take place in a continuous flow, stirred tank reactor fitted with a movable piston. Work can be produced by means of a heat engine coupled to the products and to an external heat bath, and by the piston. Two modes of operation are compared, each with fixed input rate of chemicals: one with periodic variation of an external constraint [mode (b)], in which we vary the external pressure, and one without such variation [mode (a)]. We derive equations for the total power output in each of the two modes. The power output in mode (b) can be larger than that of mode (a) for the same chemical throughput and for the same average value of the external pressure. For a particularly simple case it is shown that the total power output in mode (b) is larger than that in (a) if work is done by the piston. At the same time the entropy production is decreased and the efficiency is increased. The possibility of an increased power output is due to the proper control of the relative phase of the externally varied constraint and its conjugate variable, the external pressure and the volume. This control is achieved by the coupling of nonlinear kinetics to the externally varied constraint. Details of specific mechanisms and the occurrence of resonance phenomena are presented in the following article.
NASA Astrophysics Data System (ADS)
Ali, Amir R.; Kamel, Mohamed A.
2017-05-01
This paper studies the effect of the electrostriction force on the single optical dielectric core coated with multi-layers based on whispering gallery mode (WGM). The sensing element is a dielectric core made of polymeric material coated with multi-layers having different dielectric and mechanical properties. The external electric field deforming the sensing element causing shifts in its WGM spectrum. The multi-layer structures will enhance the body and the pressure forces acting on the core of the sensing element. Due to the gradient on the dielectric permittivity; pressure forces at the interface between every two layers will be created. Also, the gradient on Young's modulus will affect the overall stiffness of the optical sensor. In turn the sensitivity of the optical sensor to the electric field will be increased when the materials of each layer selected properly. A mathematical model is used to test the effect for that multi-layer structures. Two layering techniques are considered to increase the sensor's sensitivity; (i) Pressure force enhancement technique; and (ii) Young's modulus reduction technique. In the first technique, Young's modulus is kept constant for all layers, while the dielectric permittivity is varying. In this technique the results will be affected by the value dielectric permittivity of the outer medium surrounding the cavity. If the medium's dielectric permittivity is greater than that of the cavity, then the ascending ordered layers of the cavity will yield the highest sensitivity (the core will have the smallest dielectric permittivity) to the applied electric field and vice versa. In the second technique, Young's modulus is varying along the layers, while the dielectric permittivity has a certain constant value per layer. On the other hand, the descending order will enhance the sensitivity in the second technique. Overall, results show the multi-layer cavity based on these techniques will enhance the sensitivity compared to the typical polymeric optical sensor.
ERIC Educational Resources Information Center
Kondratuk, Tammy B.; Hausdorf, Peter A.; Korabik, Karen; Rosin, Hazel M.
2004-01-01
Today's organizations are undergoing constant and substantial change due to many internal and external forces. These changes are impacting on the inter- and intra-organizational career mobility of managers and employees. This research assessed the relationship between career mobility history and a recent internal or external job change on…
Effect of pressure and magnetic field on the electrical resistivity of TbB6
NASA Astrophysics Data System (ADS)
Sakai, Takeshi; Oomi, Gendo; Kunii, Satoru
2009-06-01
Electrical resistivity of a single crystal of TbB6 was studied under hydrostatic pressures up to 2.1 GPa and magnetic fields up to 9 T. The Néel temperature, rN, decreases linearly with increasing pressure: \\ddiff lnTN/\\ddiff P = 3.14×10-2 GPa-1 at zero external field. This pressure dependence of TN weakens as external fields increase. At ambient pressure, the magnetoresistance at 4.2 K is positive up to 4.8 T and becomes negative above 4.8 T. The positive magnetoresistance observed at ambient pressure is suppressed by applying pressure, which enhances the negative magnetoresistance. These results are interpreted in terms of the reduction of the scattering of conduction electrons, due to disordered magnetic moment being suppressed by derealization of 4f electrons at high pressure, and the magnetic field variation of the large transition probability between the ground state and the excited levels.
USDA-ARS?s Scientific Manuscript database
Control of western cherry fruit fly (Rhagoletis indifferens Curran) using thiamethoxam in sucrose bait and spinosad bait in cherry orchards under external fly pressure and its relation to rapidity of kill and residual bait activity were studied in Washington and Utah in 2010 and 2011. Thiamethoxam ...
ERIC Educational Resources Information Center
Turcato, Carolina; Barin-Cruz, Luciano; Pedrozo, Eugenio Avila
2012-01-01
Purpose: This study aims to investigate how an organic cotton production network learns to maintain its hybrid network and its sustainability in the face of internal and external pressures. Design/methodology/approach: A qualitative case study was conducted in Justa Trama, a Brazilian-based organic cotton production network formed by six members…
Investigation of the hydrochlorination of SiCl4
NASA Technical Reports Server (NTRS)
Mui, J. Y. P.
1983-01-01
A basic, experimental study on the hydrochlorination of silicon tetrachloride and metallurgical grade silicon with hydrogen gas to form trichlorosilane was carried out to greatly expand the range of reaction conditions. The equilibrium constant, K sub p, for the hydrochlorination reaction was measured as a function of temperature, pressure and concentration. The variation of the equilibrium constant as a function of temperature provided the measurement on the heat of reaction, delta H, by the Second Law Method. The value of delta H was measured to give 10.6 Kcal/mole. The equilibrium constant was also studied as a function of concentration. In agreement with the theory, the equilibrium constant remained constant with respect to the varying H2/SiCl4 feed ratios. On the other hand, the effect of pressure on the equilibrium constant was found to be more complex.
Three-dimensional imaging of dislocation dynamics during the hydriding phase transformation
NASA Astrophysics Data System (ADS)
Ulvestad, A.; Welland, M. J.; Cha, W.; Liu, Y.; Kim, J. W.; Harder, R.; Maxey, E.; Clark, J. N.; Highland, M. J.; You, H.; Zapol, P.; Hruszkewycz, S. O.; Stephenson, G. B.
2017-05-01
Crystallographic imperfections significantly alter material properties and their response to external stimuli, including solute-induced phase transformations. Despite recent progress in imaging defects using electron and X-ray techniques, in situ three-dimensional imaging of defect dynamics remains challenging. Here, we use Bragg coherent diffractive imaging to image defects during the hydriding phase transformation of palladium nanocrystals. During constant-pressure experiments we observe that the phase transformation begins after dislocation nucleation close to the phase boundary in particles larger than 300 nm. The three-dimensional phase morphology suggests that the hydrogen-rich phase is more similar to a spherical cap on the hydrogen-poor phase than to the core-shell model commonly assumed. We substantiate this using three-dimensional phase field modelling, demonstrating how phase morphology affects the critical size for dislocation nucleation. Our results reveal how particle size and phase morphology affects transformations in the PdH system.
Dargatz, Benjamin; Gonzalez-Julian, Jesus; Guillon, Olivier
2015-04-01
The retention of nanocrystallinity in dense ceramic materials is still a challenge, even with the application of external pressure during sintering. The compaction behavior of high purity and acetate enriched zinc oxide (ZnO) nano-powders was investigated. It was found that acetate in combination with water plays a key role during the compaction into green bodies at moderate temperatures. Application of constant pressure resulted in a homogeneous green body with superior packing density (86% of theoretical value) at moderate temperature (85 °C) in the presence of water. In contrast, no improvement in density could be achieved if pure ZnO powder was used. This compaction behavior offers superior packing of the particles, resulting in a high relative density of the consolidated compact with negligible coarsening. Dissolution accompanying creep diffusion based matter transport is suggested to strongly support reorientation of ZnO particles towards densities beyond the theoretical limit for packing of ideal monosized spheres. Finally, the sintering trajectory reveals that grain growth is retarded compared to conventional processing up to 90% of theoretical density. Moreover, nearly no radial shrinkage was observed after sinter-forging for bodies performed with this advanced processing method.
NASA Astrophysics Data System (ADS)
Majumder, Sambit; Majumder, Abhik; Bhaumik, Swapan
2016-07-01
The present microelectronics market demands devices with high power dissipation capabilities having enhanced cooling per unit area. The drive for miniaturizing the devices to even micro level dimensions is shooting up the applied heat flux on such devices, resulting in complexity in heat transfer and cooling management. In this paper, a method of CPU processor cooling is introduced where active and passive cooling techniques are incorporated simultaneously. A heat sink consisting of fins is designed, where water flows internally through the mini-channel fins and air flows externally. Three dimensional numerical simulations are performed for large set of Reynolds number in laminar region using finite volume method for both developing flows. The dimensions of mini-channel fins are varied for several aspect ratios such as 1, 1.33, 2 and 4. Constant temperature (T) boundary condition is applied at heat sink base. Channel fluid temperature, pressure drop are analyzed to obtain best cooling option in the present study. It has been observed that as the aspect ratio of the channel decreases Nusselt number decreases while pressure drop increases. However, Nusselt number increases with increase in Reynolds number.
Biofunctionalized Ceramic with Self-Assembled Networks of Nanochannels
Jang, Hae Lin; Lee, Keunho; Kang, Chan Soon; Lee, Hye Kyoung; Ahn, Hyo-Yong; Jeong, Hui-Yun; Park, Sunghak; Kim, Seul Cham; Jin, Kyoungsuk; Park, Jimin; Yang, Tae-Youl; Kim, Jin Hong; Shin, Seon Ae; Han, Heung Nam; Oh, Kyu Hwan; Lee, Ho-Young; Lim, Jun; Hong, Kug Sun; Snead, Malcolm L.; Xu, Jimmy; Nam, Ki Tae
2015-01-01
Nature designs circulatory systems with hierarchically organized networks of gradually tapered channels ranging from micrometer to nanometer in diameter. In most hard tissues in biological systems, fluid, gasses, nutrients and wastes are constantly exchanged through such networks. Here, we developed a biologically-inspired, hierarchically-organized structure in ceramic to achieve effective permeation with minimum void region, using fabrication methods that create a long-range, highly-interconnected nanochannel system in a ceramic biomaterial. This design of a synthetic model-material was implemented through a novel pressurized sintering process formulated to induce a gradual tapering in channel diameter based on pressure-dependent polymer agglomeration. The resulting system allows long range, efficient transport of fluid and nutrients into sites and interfaces that conventional fluid conduction cannot reach without external force. We demonstrate the ability of mammalian bone-forming cells placed at the distal transport termination of the nanochannel system to proliferate in a manner dependent solely upon the supply of media by the self-powering nanochannels. This approach mimics the significant contribution that nanochannel transport plays in maintaining living hard tissues by providing nutrient supply that facilitates cell growth and differentiation, and thereby makes the ceramic composite ‘alive’. PMID:25827409
Gonzalez-Julian, Jesus; Guillon, Olivier
2015-01-01
The retention of nanocrystallinity in dense ceramic materials is still a challenge, even with the application of external pressure during sintering. The compaction behavior of high purity and acetate enriched zinc oxide (ZnO) nano-powders was investigated. It was found that acetate in combination with water plays a key role during the compaction into green bodies at moderate temperatures. Application of constant pressure resulted in a homogeneous green body with superior packing density (86% of theoretical value) at moderate temperature (85 °C) in the presence of water. In contrast, no improvement in density could be achieved if pure ZnO powder was used. This compaction behavior offers superior packing of the particles, resulting in a high relative density of the consolidated compact with negligible coarsening. Dissolution accompanying creep diffusion based matter transport is suggested to strongly support reorientation of ZnO particles towards densities beyond the theoretical limit for packing of ideal monosized spheres. Finally, the sintering trajectory reveals that grain growth is retarded compared to conventional processing up to 90% of theoretical density. Moreover, nearly no radial shrinkage was observed after sinter-forging for bodies performed with this advanced processing method. PMID:27877777
Fluid overpressures and strength of the sedimentary upper crust
NASA Astrophysics Data System (ADS)
Suppe, John
2014-12-01
The classic crustal strength-depth profile based on rock mechanics predicts a brittle strength σ1 -σ3 = κ(ρbar gz -Pf) that increases linearly with depth as a consequence of [1] the intrinsic brittle pressure dependence κ plus [2] an assumption of hydrostatic pore-fluid pressure, Pf = ρwgz. Many deep borehole stress data agree with a critical state of failure of this form. In contrast, fluid pressures greater than hydrostatic ρbar gz >Pf >ρw gz are normally observed in clastic continental margins and shale-rich mountain belts. Therefore we explore the predicted shapes of strength-depth profiles using data from overpressured regions, especially those dominated by the widespread disequilibrium-compaction mechanism, in which fluid pressures are hydrostatic above the fluid-retention depth zFRD and overpressured below, increasing parallel to the lithostatic gradient ρbar gz . Both brittle crustal strength and frictional fault strength below the zFRD must be constant with depth because effective stress (ρbar gz -Pf) is constant, in contrast with the classic linearly increasing profile. Borehole stress and fluid-pressure measurements in several overpressured deforming continental margins agree with this constant-strength prediction, with the same pressure-dependence κ as the overlying hydrostatic strata. The role of zFRD in critical-taper wedge mechanics and jointing is illustrated. The constant-strength approximation is more appropriate for overpressured crust than classic linearly increasing models.
Numerical study of external burning flowfields
NASA Technical Reports Server (NTRS)
Bittner, Robert D.; Mcclinton, Charles R.
1991-01-01
This paper demonstrates the successful application of CFD to modeling an external burning flowfield. The study used the 2D, 3D, and PNS versions of the SPARK code. Various grids, boundary conditions, and ignition methodologies have been employed. Flameholding was achieved through the use of a subsonic outflow condition and a hot block located behind the step to ignite the fuel. Since the resulting burning produces a large subsonic region downstream of the cowl, this entire surface can be pressurized to the level of the back pressure. An evaluation of interactions between the ramjet exhaust and the external burning products demonstrate the complexity of this design issue. Ths code is now capable of evaluating the external burning effectiveness for flight vehicles using simple injector schemes, and the methodology can be readily applied to other external burning designs.
21 CFR 868.2700 - Pressure regulator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... purposes and that is used to convert a medical gas pressure from a high variable pressure to a lower, more constant working pressure. This device includes mechanical oxygen regulators. (b) Classification. Class I...
Effect of Detonation through a Turbine Stage
NASA Technical Reports Server (NTRS)
Ellis, Matthew T.
2004-01-01
Pulse detonation engines (PDE) have been investigated as a more efficient means of propulsion due to its constant volume combustion rather than the more often used constant pressure combustion of other propulsion systems. It has been proposed that a hybrid PDE-gas turbine engine would be a feasible means of improving the efficiency of the typical constant pressure combustion gas turbine cycle. In this proposed system, multiple pulse detonation tubes would replace the conventional combustor. Also, some of the compressor stages may be removed due to the pressure rise gained across the detonation wave. The benefits of higher thermal efficiency and reduced compressor size may come at a cost. The first question that arises is the unsteadiness in the flow created by the pulse detonation tubes. A constant pressure combustor has the advantage of supplying a steady and large mass flow rate. The use of the pulse detonation tubes will create an unsteady mass flow which will have currently unknown effects on the turbine located downstream of the combustor. Using multiple pulse detonation tubes will hopefully improve the unsteadiness. The interaction between the turbine and the shock waves exiting the tubes will also have an unknown effect. Noise levels are also a concern with this hybrid system. These unknown effects are being investigated using TURBO, an unsteady turbomachinery flow simulation code developed at Mississippi State University. A baseline case corresponding to a system using a constant pressure combustor with the same mass flow rate achieved with the pulse detonation hybrid system will be investigated first.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dadfarnia, Mohsen; Nibur, Kevin A.; San Marchi, Christopher W.
2010-07-01
Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} ismore » the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nibur, Kevin A.
2010-11-01
Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} ismore » the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.« less
Ideal relaxation of the Hopf fibration
NASA Astrophysics Data System (ADS)
Smiet, Christopher Berg; Candelaresi, Simon; Bouwmeester, Dirk
2017-07-01
Ideal magnetohydrodynamics relaxation is the topology-conserving reconfiguration of a magnetic field into a lower energy state where the net force is zero. This is achieved by modeling the plasma as perfectly conducting viscous fluid. It is an important tool for investigating plasma equilibria and is often used to study the magnetic configurations in fusion devices and astrophysical plasmas. We study the equilibrium reached by a localized magnetic field through the topology conserving relaxation of a magnetic field based on the Hopf fibration in which magnetic field lines are closed circles that are all linked with one another. Magnetic fields with this topology have recently been shown to occur in non-ideal numerical simulations. Our results show that any localized field can only attain equilibrium if there is a finite external pressure, and that for such a field a Taylor state is unattainable. We find an equilibrium plasma configuration that is characterized by a lowered pressure in a toroidal region, with field lines lying on surfaces of constant pressure. Therefore, the field is in a Grad-Shafranov equilibrium. Localized helical magnetic fields are found when plasma is ejected from astrophysical bodies and subsequently relaxes against the background plasma, as well as on earth in plasmoids generated by, e.g., a Marshall gun. This work shows under which conditions an equilibrium can be reached and identifies a toroidal depression as the characteristic feature of such a configuration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebey, Peter S.; Dole, James M.; Geller, Drew A.
2005-11-15
Beta-layering, the process of beta-decay heat-driven mass redistribution, has been demonstrated in a deuterium-tritium (D-T)-filled polymer sphere of the type required for fusion ignition experiments at the National Ignition Facility. This is the first report, to the best of the authors' knowledge, of a D-T layer formed in a permeation-filled sphere. The 2-mm-diam sphere was filled with D-T by permeation; cooled to cryogenic temperatures while in the high-pressure permeation vessel; and, while cold, removed to an optical axis where the D-T was frozen, melted, and beta-layered in a series of experiments over several weeks' time. This work was performed inmore » the Los Alamos National Laboratory cryogenic pressure loader system. The beta-layering time constant was 24.0 {+-} 2.5 min, less than the theoretical value of 26.8 min, and not showing the significant increase due to build-up of {sup 3}He often observed in beta-layered samples. Supercooling of the liquid D-T was observed. Neither the polymer target nor its tenting material showed visual signs of degradation after 5 weeks of exposure to D-T. Small external thermal gradients were used to shift the D-T material back and forth within the sphere.« less
Three-dimensional imaging of dislocation dynamics during the hydriding phase transformation
Ulvestad, A.; Welland, M. J.; Cha, W.; ...
2017-01-16
Crystallographic imperfections can significantly alter material properties and responses to external stimuli, including solute induced phase transformations and crystal growth and dissolution . Despite recent progress in imaging defects using both electron and x-ray techniques, in situ three-dimensional imaging studies of defect dynamics, necessary to understand and engineer nanoscale processes, remains challenging. Here, we report in situ three-dimensional imaging of defect dynamics during the hydriding phase transformation of individual palladium nanocrystals by Bragg Coherent Diffractive Imaging (BCDI) . During constant pressure experiments, we observed that the phase transformation begins after the nucleation of dislocations in large (300 nm) particles. Themore » 3D dislocation network shows that dislocations are close to the phase boundary. The 3D phase morphology resolved by BCDI suggests that the hydrogen-rich phase is more similar to a spherical cap on the hydrogen-poor phase than the core-shell model commonly assumed. We substantiate this conclusion using 3D phase field modeling and demonstrate how phase morphology affects the critical size for dislocation nucleation. We determine the size dependence of the transformation pressure for large (150-300 nm) palladium nanocrystals using variable pressure experiments. Our results reveal a pathway for solute induced structural phase transformations in nanocrystals and demonstrate BCDI as a novel method for understanding dislocation dynamics in phase transforming systems at the nanoscale.« less
Bahng, Mi-Kyung; Macdonald, R Glen
2008-12-25
The rate constant for the reaction NH(2)(X(2)B(1)) + NH(2)(X(2)B(1)) --> products was measured in CF(4), N(2) and Ar carrier gases at 293 +/- 2 K over a pressure range from 2 to 10 Torr. The NH(2) radical was produced by the 193 nm photolysis of NH(3) dilute in the carrier gas. Both the loss of NH(3) and its subsequent recovery and the production of NH(2) and subsequent reaction were monitored simultaneously following the photolysis laser pulse. Both species were detected using quantitative time-resolved high-resolution absorption spectroscopy. The NH(3) molecule was monitored in the NIR using a rotation transition of the nu(1) + nu(3) first combination band near 1500 nm, and the NH(2) radical was monitored using the (1)2(21) <-- (1)3(31) rotational transition of the (0,7,0)A(2)A(1) <-- (0,0,0) X(2)B(1) band near 675 nm. The low-pressure rate constant showed a linear dependence on pressure. The slope of the pressure dependence was dominated by a recombination rate constant for NH(2) + NH(2) given by (8.0 +/- 0.5) x 10(-29), (5.7 +/- 0.7) x 10(-29), and (3.9 +/- 0.4) x 10(-29) cm(6) molecule(-2) s(-1) in CF(4), N(2), and Ar bath gases, respectively, where the uncertainties are +/-2sigma in the scatter of the measurements. The average of the three independent measurements of the sum of the disproportionation rate constants (the zero pressure rate constant) was (3.4 +/- 6) x 10(-13) cm(3) molecule(-1) s(-1), where the uncertainty is +/-2sigma in the scatter of the measurements.
Fouling resilient perforated feed spacers for membrane filtration.
Kerdi, Sarah; Qamar, Adnan; Vrouwenvelder, Johannes S; Ghaffour, Noreddine
2018-04-24
The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50%-61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L m -2 .h -1 and 6.6 L m -2 .h -1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those observed with other perforated spacers, resulting in the cleanest membrane surface. Copyright © 2018 Elsevier Ltd. All rights reserved.
Geomagnetic Storm Effects in the Low- to Middle-Latitude Upper Thermosphere
NASA Technical Reports Server (NTRS)
Burns, A. G.; Killeen, T. L.; Deng, W.; Carignan, G. R.; Roble, R. G.
1995-01-01
In this paper, we use data from the Dynamics Explorer 2 (DE 2) satellite and a theoretical simulation made by using the National Center for Atmospheric Research thermosphere/ionosphere general circulation model (NCAR-TIGCM) to study storm-induced changes in the structure of the upper thermosphere in the low- to middle-latitude (20 deg-40 deg N) region of the winter hemisphere. Our principal results are as follows: (1) The winds associated with the diurnal tide weaken during geomagnetic storms, causing primarily zonally oriented changes in the evening sector, few changes in the middle of the afternoon, a combination of zonal and meridional changes in the late morning region, and mainly meridional changes early in the morning; (2) Decreases in the magnitudes of the horizontal winds associated with the diurnal tide lead to a net downward tendency in the vertical winds blowing through a constant pressure surface; (3) Because of these changes in the vertical wind, there is an increase in compressional heating (or a decrease in cooling through expansion), and thus temperatures in the low- to middle-latitudes of the winter hemisphere increase; (4) Densities of all neutral species increase on a constant height surface, but the pattern of changes in the O/N2 ratio is not well ordered on these surfaces; (5) The pattern of changes in the O/N2 ratio is better ordered on constant pressure surfaces. The increases in this ratio on constant pressure surfaces in the low- to middle-latitude, winter hemisphere are caused by a more downward tendency in the vertical winds that blow through the constant pressure surfaces. Nitrogen-poor air is then advected downward through the pressure surface, increasing the O/N2 ratio; (6) The daytime geographical distribution of the modeled increases in the O/N2 ratio on a constant pressure surface in the low- to middle-latitudes of the winter hemisphere correspond very closely with those of increases in the modeled electron densities at the F2 peak.
NASA Technical Reports Server (NTRS)
Thornton, D. E.
1976-01-01
Tests were conducted in a 14 foot transonic wind tunnel to examine the feasibility of the auxiliary aerodynamic data system (AADS) for determining angles of attack and sideslip during boost flight. The model used was a 0.07 scale replica of the external tank forebody consisting of the nose portion and a 60 inch (full scale) cylindrical section of the ogive cylinder tangency point. The model terminated in a blunt base with a 320.0 inch diameter at external tank (ET) station 1120.37. Pressure data were obtained from five pressure orifices (one total and four statics) on the nose probe, and sixteen surface static pressure orifices along the ET forebody.
On the internal structure of relativistic jets collimated by ambient gas pressure
NASA Astrophysics Data System (ADS)
Beskin, V. S.; Chernoglazov, A. V.; Kiselev, A. M.; Nokhrina, E. E.
2017-12-01
Recent progress in very long baseline interferometry (VLBI) observations of relativistic jets outflowing from active galactic nuclei gives us direct information about jet width rjet(l) dependence on the distance l from the 'central engine'. Being the missing link in previous works, this relation opens the possibility of determining the internal structure of a jet. In this article, we consider a relativistic jet submerged in an external medium with finite gas pressure Pext. Neither an external magnetic field nor an infinitely thin current sheet will be assumed. This approach allows us to construct a reasonable solution in which both the magnetic field and the flow velocity vanish at the jet boundary r = rjet. In particular, the connection between external gas pressure and internal structure of a relativistic jet is determined.
Stapes Displacement and Intracochlear Pressure in Response to Very High Level, Low Frequency Sounds
Greene, Nathaniel T.; Jenkins, Herman A.; Tollin, Daniel J.; Easter, James R.
2018-01-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (< 130 dB SPL) sound levels intracochlear pressure (PIC), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (DStap), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak PIC will vary linearly with DStap up to some saturation point. However, no direct tests of DStap, or of the relationship with PIC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between DStap and PIC to very high level sounds, measurements of DStap and PIC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of PIC were made in scala vestibuli (PSV) and scala tympani (PST), along with the SPL in the external auditory canal (PEAC), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (VStap). Stimuli were moderate (~100 dB SPL) to very high level (up to ~170 dB SPL), low frequency tones (20–2560 Hz). Both DStap and PSV increased proportionally with sound pressure level in the ear canal up to approximately ~150 dB SPL, above which both DStap and PSV showed a distinct deviation from proportionality with PEAC. Both DStap and PSV approached saturation: DStap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while PSV showed substantial frequency dependence in the saturation point. The relationship between PSV and DStap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that PSV sound pressure holds constant relationship with DStap, described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. PMID:28189837
A study of nonlinear dynamics of single- and two-phase flow oscillations
NASA Astrophysics Data System (ADS)
Mawasha, Phetolo Ruby
The dynamics of single- and two-phase flows in channels can be contingent on nonlinearities which are not clearly understood. These nonlinearities could be interfacial forces between the flowing fluid and its walls, variations in fluid properties, growth of voids, etc. The understanding of nonlinear dynamics of fluid flow is critical in physical systems which can undergo undesirable system operating scenarios such an oscillatory behavior which may lead to component failure. A nonlinear lumped mathematical model of a surge tank with a constant inlet flow into the tank and an outlet flow through a channel is derived from first principles. The model is used to demonstrate that surge tanks with inlet and outlet flows contribute to oscillatory behavior in laminar, turbulent, single-phase, and two-phase flow systems. Some oscillations are underdamped while others are self-sustaining. The mechanisms that are active in single-phase oscillations with no heating are presented using specific cases of simplified models. Also, it is demonstrated how an external mechanism such as boiling contributes to the oscillations observed in two-phase flow and gives rise to sustained oscillations (or pressure drop oscillations). A description of the pressure drop oscillation mechanism is presented using the steady state pressure drop versus mass flow rate characteristic curve of the heated channel, available steady state pressure drop versus mass flow rate from the surge tank, and the transient pressure drop versus mass flow rate limit cycle. Parametric studies are used to verify the theoretical pressure drop oscillations model using experimental data by Yuncu's (1990). The following contributions are unique: (1) comparisons of nonlinear pressure drop oscillation models with and without the effect of the wall thermal heat capacity and (2) comparisons of linearized pressure drop oscillation models with and without the effect of the wall thermal heat capacity to identify stability boundaries.
40 CFR 796.1950 - Vapor pressure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gases until the measured vapor pressure is constant, a process called “degassing.” Impurities more... simulations. Vapor pressure is computed on the assumption that the total pressure of a mixture of gases is...
External stimulation strength controls actin response dynamics in Dictyostelium cells
NASA Astrophysics Data System (ADS)
Hsu, Hsin-Fang; Westendorf, Christian; Tarantola, Marco; Zykov, Vladimir; Bodenschatz, Eberhard; Beta, Carsten
2015-03-01
Self-sustained oscillation and the resonance frequency of the cytoskeletal actin polymerization/depolymerization have recently been observed in Dictyostelium, a model system for studying chemotaxis. Here we report that the resonance frequency is not constant but rather varies with the strength of external stimuli. To understand the underlying mechanism, we analyzed the polymerization and depolymerization time at different levels of external stimulation. We found that polymerization time is independent of external stimuli but the depolymerization time is prolonged as the stimulation increases. These observations can be successfully reproduced in the frame work of our time delayed differential equation model.
Gene delivery by direct injection (microinjection) using a controlled-flow system.
Dean, David A
2006-12-01
INTRODUCTIONThis protocol describes a method for constant-flow microinjection using the Pneumatic PicoPump (World Precision Instruments). This type of system is very simple and can be assembled on a relatively low budget. In this method, a constant flow of sample is delivered from the tip of the pipette, and the amount of sample injected into the cell is determined by how long the pipette remains in the cell. A typical system is composed of a pressure regulator that can be adjusted for two pressures (back pressure and injection pressure), a capillary holder, and a coarse and fine micromanipulator.
Noise effects on the health status in a dynamic failure model for living organisms
NASA Astrophysics Data System (ADS)
Kang, H.; Jo, J.; Choi, M. Y.; Choi, J.; Yoon, B.-G.
2007-03-01
We study internal and external noise effects on the healthy-unhealthy transition and related phenomena in a dynamic failure model for living organisms. It is found that internal noise makes the system weaker, leading to breakdown under smaller stress. The discontinuous healthy-unhealthy transition in a system with global load sharing below a critical point is naturally explained in terms of the bistability for the health status. External noise present in constant stress gives similar results; further, it induces resonance in response to periodic stress, regardless of load transfer. In the case of local load sharing, such periodic stress is revealed more hazardous than the constant stress.
A programmable point-of-care device for external CSF drainage and monitoring.
Simkins, Jeffrey R; Subbian, Vignesh; Beyette, Fred R
2014-01-01
This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.
ERIC Educational Resources Information Center
Brown, Shawn M.
2012-01-01
This thesis examined the role of strategic marketing in organizational adaptation to a rapidly changing and competitive external environment among institutions of higher education. Colleges and universities adapt to external pressures as open systems operating within a broader external environment (Bess & Dee, 2008; Keller, 1983). How does…
Ion energy distribution and gas heating in the cathode fall of a direct-current microdischarge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ito, Tsuyohito; Cappelli, Mark A.
2006-04-15
This paper reports on measurements of the ion energy distribution (IED) at the cathode of an argon dc microdischarge using energy-resolved molecular beam mass spectrometry. The measurements are conducted at a fixed pressure-electrode separation product (pd) of 1 cm Torr with a maximum discharge pressure of 20 Torr. The measured IED is compared to the theory of Davis and Vanderslice [W. D. Davis and T. A. Vanderslice, Phys. Rev. 131, 219 (1963)]. A higher pressure in a case of almost constant normalized current densities by pressure (Jp{sup -2}=0.080{+-}0.006 mAecm{sup -2} Torr{sup -2}) yields a lower ratio of the ion meanmore » free path to the sheath thickness. The results in almost constant Jp{sup -2} case then indicate that a scaling law of Jp{sup -2} is no longer applicable for IED of microdischarge. Expected background gaseous temperatures from IEDs with the collisional Child law have reasonable increasing with increased current density (J) in both cases of almost constant Jp{sup -2} and a constant pressure of 10 Torr. Supported by temperature measurement by laser absorption spectroscopy, it is demonstrated that the expanded theory might be applicable also to microdischarges (Ar{approx}20 Torr) with temperature adjusting.« less
Kim, Yong Doo; Kang, Ji Hwan; Bae, Hyun Kil; Kang, Namgoo; Oh, Sang Hyub; Lee, Jin-Hong; Woo, Jin Chun; Lee, Sangil
2017-11-21
Liquid hydrocarbon mixtures such as liquefied petroleum gas and liquefied natural gas are becoming integral parts of the world's energy system. Certified reference materials (CRMs) of liquid hydrocarbon mixtures are necessary to allow assessment of the accuracy and traceability of the compositions of such materials. A piston-type constant-pressure cylinder (PCPC) comprising chambers for a pressurizing gas (helium) and liquid (hydrocarbons) separated by a piston can be used to develop accurate and traceable liquid hydrocarbon mixture CRMs. The development of accurate CRMs relies on the maintenance of their composition. However, a PCPC might allow hydrocarbons to leak owing to the imperfect seal of the piston. In this study, a novel leak-free bellows-type constant-pressure cylinder (BCPC) is designed and evaluated by comparison with PCPCs. Liquid hydrocarbon mixtures consisting of ethane, propane, propene, isobutane, n-butane, 1-butene, and isopentane were prepared in both types of constant pressure cylinders and then monitored to check leakages between the gas and liquid chambers. Overall, notable leakage occurred from and into both chambers in the PCPCs, whereas no leakage occurred in the BCPCs in the three months after their gravimetric preparation. The BCPCs maintained no leakage even 10 months after their preparation, whereas the PCPCs showed significantly increasing leakage during the same period.
Peng, Shoujian; Fang, Zhiming; Shen, Jian; Xu, Jiang; Wang, Geoff
2017-10-30
The cleat compressibility of coal is a key parameter that is extensively used in modeling the coal reservoir permeability for Coal Bed Methane (CBM) recovery. Cleat compressibility is often determined from the permeability measurement made at different confining pressures but with a constant pore pressure. Hence, this parameter ignores the sorption strain effects on the cleat compressibility. By using the transient pulse decay (TPD) technique, this study presents the results from a laboratory characterization program using coal core drilled from different bedding directions to estimate gas permeability and coal cleat compressibility under different pore pressures while maintaining effective stress constant. Cleat compressibility was determined from permeability and sorption strain measurements that are made at different pore pressures under an effective stress constant. Results show that the cleat compressibility of coal increases slightly with the increase of pore pressure. Moreover, the cleat compressibility of Sample P (representing the face cleats in coal) is larger than that of Sample C (representing the butt cleats in coal). This result suggests that cleat compressibility should not be regarded as constant in the modeling of the CBM recovery. Furthermore, the compressibility of face cleats is considerably sensitive to the sorption-induced swelling/shrinkage and offers significant effects on the coal permeability.
NASA Technical Reports Server (NTRS)
Simmonds, A. L.; Miller, C. G., III; Nealy, J. E.
1976-01-01
Equilibrium thermodynamic properties for pure ammonia were generated for a range of temperature from 500 to 50,000 K and pressure from 0.01 to 40 MN/sq m and are presented in tabulated and graphical form. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular-weight ratio, specific heat at constant pressure, specific heat at constant volume, isentropic exponent, and species mole fractions. These properties were calculated by the method which is based on minimization of the Gibbs free energy. The data presented herein are for an 18-species ammonia model. Heats of formation and spectroscopic constants used as input data are presented. Comparison of several thermodynamic properties calculated with the present program and a second computer code is performed for a range of pressure and for temperatures up to 30,000 K.
Frost heave susceptibility of saturated soil under constant rate of freezing
NASA Astrophysics Data System (ADS)
Ryokai, K.; Iguro, M.; Yoneyama, K.
Introduced are the results of experiments carried out to quantitatively obtain the frost heave pressure and displacement of soil subjected to artificial freezing or freezing around in-ground liquefied natural gas storage tanks. This experiment is conducted to evaluate the frost heave susceptibility of saturated soil under overconsolidation. In other words, this experiment was carried out to obtain the relation of the over-burden pressure and freezing rate to the frost heave ratio by observing the frost heave displacement and freezing time of specimens by freezing the specimens at a constant freezing rate under a constant overburden pressure, while letting water freely flow in and out of the system. Introduced are the procedures for frost heave test required to quantitatively obtain the frost heave displacement and pressure of soil. Furthermore, the relation between the frost heave susceptibility and physical properties of soil obtained by this test is reported.
NASA Astrophysics Data System (ADS)
Çoban, Cansu
2017-08-01
The pressure dependent behaviour of the structural, electronic, mechanical, vibrational, and thermodynamic properties of Pd2TiX (X=Ga, In) Heusler alloys was investigated by ab initio calculations. The lattice constant, the bulk modulus and its first pressure derivative, the electronic band structure and the density of states (DOS), mechanical properties such as elastic constants, anisotropy factor, Young's modulus, etc., the phonon dispersion curves and phonon DOS, entropy, heat capacity, and free energy were obtained under pressure. It was determined that the calculated lattice parameters are in good agreement with the literature, the elastic constants obey the stability criterion, and the phonon dispersion curves have no negative frequency which shows that the compounds are stable. The band structures at 0, 50, and 70 GPa showed valence instability at the L point which explains the superconductivity in Pd2TiX (X=Ga, In).
On the etiology of the electric activity of the external anal and urethral sphincters.
Shafik, Ali A; Shafik, Ismail A; El Sibai, Olfat
2014-10-01
In a previous study, the external anal sphincter (EAS) in dogs, known to consist of skeletal muscle fibers, was proved to contain bundles of smooth muscle fibers in between as well. Cause of electric activity in the external anal and urethral sphincters is not known; the current study investigated this point. Slices from external anal and urethral sphincters of 21 cadavers (12 male, 9 female). Eighth were fully and mat wide neonates, 13 were adults, were stained with hematoxylin and eosin, Masson's trichrome and succinic dehydrogenase, and examined microscopically. Eighteen healthy volunteers, electromyography activity of their external anal and urethral sphincters was recorded at rest, on coughing, after pudendal nerve block and after drotaverine administration, (a smooth muscle relaxant). Anal and urethral pressures were also measured. Microscopic studies have shown that both external anal and urethral sphincters were formed of bundles of smooth muscle fibers present in between the skeletal muscle fibers. Bilateral pudendal nerve block did not abolish the external anal or the urethral sphincters electromyography activity at rest, or on coughing, and did not cause significant anal or urethral pressure changes (p > .05). Drotaverine administration lead to disappearance of the electromyography activity and significant decline of the anal and urethral pressures (p < .05). The results were reproducible when the tests were repeated in the same subject. Histologic examination revealed the presence of smooth muscle fibers, between the skeletal fibers of the external anal and urethral sphincters. Evidence suggests that the smooth muscle fibers are the source of the electric activity of the sphincters and might explain some physiologic phenomena such as the external anal contraction on rectal distension or on coughing.
Intraocular pressure reduction and regulation system
NASA Technical Reports Server (NTRS)
Baehr, E. F.; Burnett, J. E.; Felder, S. F.; Mcgannon, W. J.
1979-01-01
An intraocular pressure reduction and regulation system is described and data are presented covering performance in: (1) reducing intraocular pressure to a preselected value, (2) maintaining a set minimum intraocular pressure, and (3) reducing the dynamic increases in intraocular pressure resulting from external loads applied to the eye.
CFD simulation and experimental validation of a GM type double inlet pulse tube refrigerator
NASA Astrophysics Data System (ADS)
Banjare, Y. P.; Sahoo, R. K.; Sarangi, S. K.
2010-04-01
Pulse tube refrigerator has the advantages of long life and low vibration over the conventional cryocoolers, such as GM and stirling coolers because of the absence of moving parts in low temperature. This paper performs a three-dimensional computational fluid dynamic (CFD) simulation of a GM type double inlet pulse tube refrigerator (DIPTR) vertically aligned, operating under a variety of thermal boundary conditions. A commercial computational fluid dynamics (CFD) software package, Fluent 6.1 is used to model the oscillating flow inside a pulse tube refrigerator. The simulation represents fully coupled systems operating in steady-periodic mode. The externally imposed boundary conditions are sinusoidal pressure inlet by user defined function at one end of the tube and constant temperature or heat flux boundaries at the external walls of the cold-end heat exchangers. The experimental method to evaluate the optimum parameters of DIPTR is difficult. On the other hand, developing a computer code for CFD analysis is equally complex. The objectives of the present investigations are to ascertain the suitability of CFD based commercial package, Fluent for study of energy and fluid flow in DIPTR and to validate the CFD simulation results with available experimental data. The general results, such as the cool down behaviours of the system, phase relation between mass flow rate and pressure at cold end, the temperature profile along the wall of the cooler and refrigeration load are presented for different boundary conditions of the system. The results confirm that CFD based Fluent simulations are capable of elucidating complex periodic processes in DIPTR. The results also show that there is an excellent agreement between CFD simulation results and experimental results.
Cuskley, Christine F; Pugliese, Martina; Castellano, Claudio; Colaiori, Francesca; Loreto, Vittorio; Tria, Francesca
2014-01-01
Human languages are rule governed, but almost invariably these rules have exceptions in the form of irregularities. Since rules in language are efficient and productive, the persistence of irregularity is an anomaly. How does irregularity linger in the face of internal (endogenous) and external (exogenous) pressures to conform to a rule? Here we address this problem by taking a detailed look at simple past tense verbs in the Corpus of Historical American English. The data show that the language is open, with many new verbs entering. At the same time, existing verbs might tend to regularize or irregularize as a consequence of internal dynamics, but overall, the amount of irregularity sustained by the language stays roughly constant over time. Despite continuous vocabulary growth, and presumably, an attendant increase in expressive power, there is no corresponding growth in irregularity. We analyze the set of irregulars, showing they may adhere to a set of minority rules, allowing for increased stability of irregularity over time. These findings contribute to the debate on how language systems become rule governed, and how and why they sustain exceptions to rules, providing insight into the interplay between the emergence and maintenance of rules and exceptions in language.
Cuskley, Christine F.; Pugliese, Martina; Castellano, Claudio; Colaiori, Francesca; Loreto, Vittorio; Tria, Francesca
2014-01-01
Human languages are rule governed, but almost invariably these rules have exceptions in the form of irregularities. Since rules in language are efficient and productive, the persistence of irregularity is an anomaly. How does irregularity linger in the face of internal (endogenous) and external (exogenous) pressures to conform to a rule? Here we address this problem by taking a detailed look at simple past tense verbs in the Corpus of Historical American English. The data show that the language is open, with many new verbs entering. At the same time, existing verbs might tend to regularize or irregularize as a consequence of internal dynamics, but overall, the amount of irregularity sustained by the language stays roughly constant over time. Despite continuous vocabulary growth, and presumably, an attendant increase in expressive power, there is no corresponding growth in irregularity. We analyze the set of irregulars, showing they may adhere to a set of minority rules, allowing for increased stability of irregularity over time. These findings contribute to the debate on how language systems become rule governed, and how and why they sustain exceptions to rules, providing insight into the interplay between the emergence and maintenance of rules and exceptions in language. PMID:25084006
NASA Astrophysics Data System (ADS)
Bravo, Teresa; Maury, Cédric
2018-03-01
This paper describes analytical and experimental studies carried out to examine the attenuation and absorption properties of rigidly-backed fibrous anisotropic materials in contact with a uniform mean flow. The aim is to provide insights for the development of non-locally reacting wall-treatments able to dissipate the noise induced by acoustic excitations over in-duct or external lining systems. A model of sound propagation in anisotropic bulk-reacting liners is presented that fully accounts for anisotropic losses due to heat conduction, viscous dissipation and diffusion processes along and across the material fibres as well as for the convective effect of an external flow. The propagation constant for the least attenuated mode of the coupled system is obtained using a simulated annealing search method. The predicted acoustical performance is validated in the no-flow case for a wide range of fibre diameters. They are assessed against impedance tube and free-field pressure-velocity measurements of the normal incidence absorption coefficient and surface impedance. Parametric studies are then conducted to determine the key constitutive parameters such as the fibres orientation or the amount of anisotropy that mostly influence the axial attenuation or the normal absorption. They are supported by a low-frequency approximation to the axial attenuation under a low-speed flow.
NASA Technical Reports Server (NTRS)
Hwang, Kyu C.; Tiwari, Surrendra N.; Miley, Stanley J.
1995-01-01
In recent years, active research has been conducted to study the technological feasibility of supersonic laminar flow control on the wing of the High Speed Civil Transport (HSCT). For this study, the F-16XL has been chosen due to its highly swept crank wing planform that closely resembles the HSCT configurations. During flights, it is discovered that the shock wave generated from the aircraft inlet introduces disturbances on the wing where the data acquisition is conducted. The flow field about a supersonic inlet is characterized by a complex three dimensional pattern of shock waves generated by the geometrical configuration of a deflector and a cowl lip. Hence, in this study, experimental method is employed to investigate the effects of the variation of deflector configuration on the flow field, and consequently, the possibility of diverting the incoming shock-disturbances away from the test section. In the present experiments, a model composed of a simple circular tube with a triangular deflector is designed to study the deflector length and the deflector base width variation in the flow field. Experimental results indicate that the lowest external pressure ratio is observed at the junction where the deflector lip and the inlet cowl lip merge. Also, it is noted that the external pressure ratio, the internal pressure ratio, the coefficient of spillage drag, and the shock standoff distance decrease as the deflector length increases. In addition, the Redefined Total Pressure Recovery Ratio (RTPRR) increases with an increase in the deflector length. Results from the study of the effect of the deflector's base width variation on the flow field indicate that the lowest external pressure ratio is observed at the junction between the inlet cowl lip and the deflector lip. As the base width of the deflector increases, the external pressure ratio at 0 rotation increases, whereas the external pressure ratio at 180 rotation decreases. In addition, the internal pressure ratio and the coefficient of spillage drag decrease as the base width of the deflector increases. However, RTPRR and shock standoff distance increase as the base width increases. In conclusion, as deflector dimensions vary, distinctive patterns in the pressure variation around the inlet deflector are observed. With an increase in the deflector length and base width, the magnitude of shock-disturbances are weakened due to a decrease in the external pressure ratio. Also, as the deflector length and base width increase, a smaller bow shock angle is formed. Therefore, the inlet shock wave formation would be significantly altered, and consequently, shock disturbances on the wing test section can be avoided through appropriately designing the deflector.
The SPARC vapor pressure and activity coefficient models were coupled to estimate Henry’s Law Constant (HLC) in water and in hexadecane for a wide range of non-polar and polar solute organic compounds without modification to/or additional parameterization of the vapor pressure or...
Measuring Time-Averaged Blood Pressure
NASA Technical Reports Server (NTRS)
Rothman, Neil S.
1988-01-01
Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.
Ankle Joint Contact Loads and Displacement With Progressive Syndesmotic Injury.
Hunt, Kenneth J; Goeb, Yannick; Behn, Anthony W; Criswell, Braden; Chou, Loretta
2015-09-01
Ligamentous injuries to the distal tibiofibular syndesmosis are predictive of long-term ankle dysfunction. Mild and moderate syndesmotic injuries are difficult to stratify, and the impact of syndesmosis injury on the magnitude and distribution of forces within the ankle joint during athletic activities is unknown. Eight below-knee cadaveric specimens were tested in the intact state and after sequential sectioning of the following ligaments: anterior-inferior tibiofibular, anterior deltoid (1 cm), interosseous/transverse (IOL/TL), posterior-inferior tibiofibular, and whole deltoid. In each condition, specimens were loaded in axial compression to 700 N and then externally rotated to 20 N·m torque. During axial loading and external rotation, both the fibula and the talus rotated significantly after each ligament sectioning as compared to the intact condition. After IOL/TL release, a significant increase in posterior translation of the fibula was observed, although no syndesmotic widening was observed. Mean tibiotalar contact pressure increased significantly after IOL/TL release, and the center of pressure shifted posterolaterally, relative to more stable conditions, after IOL/TL release. There were significant increases in mean contact pressure and peak pressure along with a reduction in contact area with axial loading and external rotation as compared to axial loading alone for all 5 conditions. Significant increases in tibiotalar contact pressures occur when external rotation stresses are added to axial loading. Moderate and severe injuries are associated with a significant increase in mean contact pressure combined with a shift in the center of pressure and rotation of the fibula and talus. Considerable changes in ankle joint kinematics and contact mechanics may explain why moderate syndesmosis injuries take longer to heal and are more likely to develop long-term dysfunction and, potentially, ankle arthritis. © The Author(s) 2015.
Choi, Eunsoo; Kim, Dongkyun; Park, Kyoungsoo
2014-12-01
For external jackets of reinforced concrete columns, shape memory alloy (SMA) wires are easy to install, and they provide active and passive confining pressure; steel plates, on the other hand, only provide passive confining pressure, and their installation on concrete is not convenient because of the requirement of a special device. To investigate how SMA wires distinctly impact bond behavior compared with steel plates, this study conducted push-out bond tests of steel reinforcing bars embedded in concrete confined by SMA wires or steel plates. For this purpose, concrete cylinders were prepared with dimensions of 100 mm x 200 mm, and D-22 reinforcing bars were embedded at the center of the concrete cylinders. External jackets of 1.0 mm and 1.5 mm thickness steel plates were used to wrap the concrete cylinders. Additionally, NiTiNb SMA wire with a diameter of 1.0 mm was wound around the concrete cylinders. Slip of the reinforcing bars due to pushing force was measured by using a displacement transducer, while the circumferential deformation of specimens was obtained by using an extensometer. The circumferential deformation was used to calculate the circumferential strains of the specimens. This study assessed the radial confining pressure due to the external jackets on the reinforcing bars at bond strength from bond stress-slip curves and bond stress-circumferential strain curves. Then, the effects of the radial confining pressure on the bond behavior of concrete are investigated, and an equation is suggested to estimate bond strength using the radial confining pressure. Finally, this study focused on how active confining pressure due to recovery stress of the SMA wires influences bond behavior.
NASA Astrophysics Data System (ADS)
Lee, Scott A.
2014-03-01
High-pressure Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the low-frequency vibrational modes of crystalline cytidine at 295 K by evaluating the logarithmic derivative of the vibrational frequency with respect to pressure: 1/ω dω/dP. Crystalline samples of molecular materials such as cytidine have vibrational modes that are localized within a molecular unit (``internal'' modes) as well as modes in which the molecular units vibrate against each other (``external'' modes). The value of the logarithmic derivative is a diagnostic probe of the nature of the eigenvector of the vibrational modes, making high pressure experiments a very useful probe for such studies. Internal stretching modes have low logarithmic derivatives while external as well as internal torsional and bending modes have higher logarithmic derivatives. All of the Raman modes below 200 cm-1 in cytidine are found to have high logarithmic derivatives, consistent with being either external modes or internal torsional or bending modes.
Pressure-flow specificity of inspiratory muscle training.
Tzelepis, G E; Vega, D L; Cohen, M E; Fulambarker, A M; Patel, K K; McCool, F D
1994-08-01
The inspiratory muscles (IM) can be trained by having a subject breathe through inspiratory resistive loads or by use of unloaded hyperpnea. These disparate training protocols are characterized by high inspiratory pressure (force) or high inspiratory flow (velocity), respectively. We tested the hypothesis that the posttraining improvements in IM pressure or flow performance are specific to training protocols in a way that is similar to force-velocity specificity of skeletal muscle training. IM training was accomplished in 15 normal subjects by use of three protocols: high inspiratory pressure-no flow (group A, n = 5), low inspiratory pressure-high flow (group B, n = 5), and intermediate inspiratory pressure and flow (group C, n = 5). A control group (n = 4) did no training. Before and after training, we measured esophageal pressure (Pes) and inspiratory flow (VI) during single maximal inspiratory efforts against a range of external resistances including an occluded airway. Efforts originated below relaxation volume (Vrel), and peak Pes and VI were measured at Vrel. Isovolume maximal Pes-VI plots were constructed to assess maximal inspiratory pressure-flow performance. Group A (pressure training) performed 30 maximal static inspiratory maneuvers at Vrel daily, group B (flow training) performed 30 sets of three maximal inspiratory maneuvers with no added external resistance daily, and group C (intermediate training) performed 30 maximal inspiratory efforts on a midrange external resistance (7 mm ID) daily. Subjects trained 5 days/wk for 6 wk. Data analysis included comparison of posttraining Pes-VI slopes among training groups.(ABSTRACT TRUNCATED AT 250 WORDS)
Aerogel Insulation Applications for Liquid Hydrogen Launch Vehicle Tanks
NASA Technical Reports Server (NTRS)
Fesmire, J. E.; Sass, J.
2007-01-01
Aerogel based insulation systems for ambient pressure environments were developed for liquid hydrogen (LH2) tank applications. Solutions to thermal insulation problems were demonstrated for the Space Shuttle External Tank (ET) through extensive testing at the Cryogenics Test Laboratory. Demonstration testing was performed using a 1/10th scale ET LH2 intertank unit and liquid helium as the coolant to provide the 20 K cold boundary temperature. Cryopumping tests in the range of 20K were performed using both constant mass and constant pressure methods. Long-duration tests (up to 10 hours) showed that the nitrogen mass taken up inside the intertank is reduced by a factor of nearly three for the aerogel insulated case as compared to the un-insulated (bare metal flight configuration) case. Test results including thermal stabilization, heat transfer effectiveness, and cryopumping confirm that the aerogel system eliminates free liquid nitrogen within the intertank. Physisorption (or adsorption) of liquid nitrogen within the fine pore structure of aerogel materials was also investigated. Results of a mass uptake method show that the sorption ratio (liquid nitrogen to aerogel beads) is about 62 percent by volume. A novel liquid nitrogen production method of testing the liquid nitrogen physical adsorption capacity of aerogel beads was also performed to more closely approximate the actual launch vehicle cooldown and thermal stabilization effects within the aerogel material. The extraordinary insulating effectiveness of the aerogel material shows that cryopumping is not an open-cell mass transport issue but is strictly driven by thermal communication between warm and cold surfaces. The new aerogel insulation technology is useful to solve heat transfer problem areas and to augment existing thermal protection systems on launch vehicles. Examples are given and potential benefits for producing launch systems that are more reliable, robust, reusable, and efficient are outlined.
NASA Astrophysics Data System (ADS)
Spagnuolo, Elena; Violay, Marie; Nielsen, Stefan; Cornelio, Chiara; Di Toro, Giulio
2017-04-01
Fluid pressure has been indicated as a major factor controlling natural (e.g., L'Aquila, Italy, 2009 Mw 6.3) and induced seismicity (e.g., Wilzetta, Oklahoma, 2011 Mw 5.7). Terzaghi's principle states that the effective normal stress is linearly reduced by a pore pressure (Pf) increase σeff=σn(1 - αPf), where the effective stress parameter α, may be related to the fraction of the fault area that is flooded. A value of α =1 is often used by default, with Pf shifting the Mohr circle towards lower normal effective stresses and anticipating failure on pre-existing faults. However, within a complex fault core of inhomogeneous permeability, α may vary in a yet poorly understood way. To shed light on this problem, we conducted experiments on calcite-bearing rock samples (Carrara marble) at room humidity conditions and in the presence of pore fluids (drained conditions) using a rotary apparatus (SHIVA). A pre-cut fault is loaded by constant shear stress τ under constant normal stress σn=15 MPa until a target value corresponding roughly to the 80 % of the frictional fault strength. The pore pressure Pf is then raised with regular pressure and time steps to induce fault instability. Assuming α=1 and a threshold for instability τp_eff=μp σeff, the experiments reveal that an increase of Pf does not necessarily induce an instability even when the effective strength threshold is largely surpassed (e.g., τp_eff=1.3 μpσeff). This result may indicate that the Pf increase did not instantly diffuse throughout the slip zone, but took a finite time to equilibrate with the external imposed pressure increase due to finite permeability. Under our experimental conditions, a significant departure from α=1 is observed provided that the Pf step is shorter than about < 20s. We interpret this delay as indicative of the diffusion time (td), which is related to fluid penetration length l by l = √ κtd-, where κ is the hydraulic diffusivity on the fault plane. We show that a simple cubic law relates td to hydraulic aperture, pore pressure gradient and injection rate. We redefine α as the ratio between the fluid penetration length and sample dimension L resulting in α = min(√ktd,L) L. Under several pore pressure loading rates this relation yields an approximate hydraulic diffusivity κ ˜10-8 m2 s-1 which is compatible, for example, with a low porosity shale. Our results highlight that a high injection flow rate in fault plane do not necessarily induce seismogenic fault slip: a critical pore penetration length or fluid patch size is necessary to trigger fault instability.
Monitoring of intracranial compliance: correction for a change in body position.
Raabe, A; Czosnyka, M; Piper, I; Seifert, V
1999-01-01
The objectives of our study were 1. to investigate whether the intracranial compliance changes with body position; 2. to test if the pressure-volume index (PVI) calculation is affected by different body positions; 3. to define the optimal parameter to correct PVI for changes in body position and 4. to investigate the physiological meaning of the constant term (P0) in the model of the intracranial volume-pressure relationship. Thirteen patients were included in this study. All patients were subjected to 2 to 3 different body positions. In each position, either classic bolus injection was performed for measurement of intracranial compliance and calculation of PVI or the new Spiegelberg compliance monitor was used to calculate PVI continuously. Four different models were used for calculating the constant pressure term P0 and the P0 corrected PVI values. Pressure volume index not corrected for the constant term P0 significantly decreased with elevating the patients head (r = 0.70, p < 0.0001). In contrast, volume-pressure response and ICP pulse amplitude did not change with position. Using the constant term P0 to correct the PVI we found no changes between the different body positions. Our results suggest that during the variation in body position there is no change in intracranial compliance but a change in hydrostatic offset pressure which causes a shifting of the volume-pressure curve along the pressure axis without its shape being affected. PVI measurements should either be performed only with the patient in the 0 degree recumbent position or that the PVI calculation should be corrected for the hydrostatic difference between the level of the ICP transducer and the hydrostatic indifference point of the craniospinal system close to the third thoracic vertebra.
Effect of Loading Efficiency on the Process of Consolidation in Unsaturated Soils
NASA Astrophysics Data System (ADS)
Lo, W. C.; Lee, J. W.; Deng, J. H.; Liu, J. H.
2016-12-01
Loading efficiency is an undrained poroelastic coefficient that causes an increase in the pore pressure due to an increase in the compressive axial stress. In order to illustrate the importance of loading efficiency on the process of consolidation in unsaturated soils, we utilize two assumptions proposed by Biot (1941) and Terzaghi (1943) to formulate the initial conditions taking account of loading efficiency and without consideration of loading efficiency, respectively. In Biot's theory (1941), he suggested that water is not allowed to escape when the external loading is instantly applied on a porous medium. Accordingly, the soil texture sample is considered to be undrained, and the linearized increment of the fluid content is equal to zero. For this reason, water and air can sustain an external loading only partially at the moment it is imposed, leading to an immediate one-dimensional consolidation. On the contrary, Terzaghi (1943) posited that as the external loading is initially applied, it is entirely sustained by the pore fluid. Thus, the initial water and air pressures are equal to the stress of external loading. Numerical calculations of excess pore water pressure and total settlement were made for a soil with clay texture as an illustrative example. A comparative study shows that in the early stage of consolidation, the model of considering loading efficiency generates larger time-dependent total settlement and also has the highest value of excess pore water pressure initially. The physical cause behind this difference is that the initial conditions established from Biot's theory is much smaller, reflecting the soil skeleton to carry most of external load at the moment it is imposed. Our results indicate that, in terms of the initial conditions for water and air pressures, the loading efficiency must be taken into account in the early stage of consolidation.
Third-order elastic constants of diamond determined from experimental data
Winey, J. M.; Hmiel, A.; Gupta, Y. M.
2016-06-01
The pressure derivatives of the second-order elastic constants (SOECs) of diamond were determined by analyzing previous sound velocity measurements under hydrostatic stress [McSkimin and Andreatch, J. Appl. Phys. 43, 294 (1972)]. Furthermore, our analysis corrects an error in the previously reported results.We present a complete and corrected set of third-order elastic constants (TOECs) using the corrected pressure derivatives, together with published data for the nonlinear elastic response of shock compressed diamond [Lang and Gupta, Phys. Rev. Lett. 106, 125502 (2011)] and it differs significantly from TOECs published previously.
Enthalpy versus entropy: What drives hard-particle ordering in condensed phases?
Anthamatten, Mitchell; Ou, Jane J.; Weinfeld, Jeffrey A.; ...
2016-07-27
In support of mesoscopic-scale materials processing, spontaneous hard-particle ordering has been actively pursued for over a half-century. The generally accepted view that entropy alone can drive hard particle ordering is evaluated. Furthermore, a thermodynamic analysis of hard particle ordering was conducted and shown to agree with existing computations and experiments. Conclusions are that (i) hard particle ordering transitions between states in equilibrium are forbidden at constant volume but are allowed at constant pressure; (ii) spontaneous ordering transitions at constant pressure are driven by enthalpy, and (iii) ordering under constant volume necessarily involves a non-equilibrium initial state which has yet tomore » be rigorously defined.« less
Variations of Thermal Pressure for Solids along the Principal Hugoniot
NASA Astrophysics Data System (ADS)
Gong, Zizheng; Yu, Hui; Deng, Liwei; Zhang, Li; Yang, Jinke
2006-07-01
The behavior of thermal pressure PTH for all kinds of solid materials was investigated using the lattice dynamics theory up to 500GPa. The results show that for most metals, ionic crystal and minerals, the thermal pressure is approximately independent on volume, whereas the thermal pressure of a few solids has strong dependence on volume. The volume dependence of thermal pressure has no relation with the chemical bonding type and crystal structure of materials, but is correlated with the Debye temperature ΘD and the second Grüneisen parameter q. The ratio of the thermal pressure to the total pressure (PTH /PTotal) along the Hugoniot keeps constant over a wide compression range, not only for non-porous materials but also for porous materials within certain porosity, which could explain the existence of material constant parameter β along solid Hugoniot.
NASA Astrophysics Data System (ADS)
Makedonska, N.; Sparks, D. W.; Aharonov, E.
2012-12-01
Pressure solution (also termed chemical compaction) is considered the most important ductile deformation mechanism operating in the Earth's upper crust. This mechanism is a major player in a variety of geological processes, including evolution of sedimentary basins, hydrocarbon reservoirs, aquifers, earthquake recurrence cycles, and fault healing. Pressure solution in massive rocks often localizes into solution seams or stylolites. Field observations of stylolites often show elastic/brittle interactions in regions between pressure solution features, including and shear fractures, veins and pull-apart features. To understand these interactions, we use a grain-scale model based on the Discrete Element Method that allows granular dissolution at stressed contacts between grains. The new model captures both the slow chemical compaction process and the more abrupt brittle fracturing and sliding between grains. We simulate a sample of rock as a collection of particles, each representing either a grain or a unit of rock, bonded to each other with breakable cement. We apply external stresses to this sample, and calculate elastic and frictional interactions between the grains. Dissolution is modeled by an irreversible penetration of contacting grains into each other at a rate that depends on the contact stress and an adjustable rate constant. Experiments have shown that dissolution rates at grain contacts are greatly enhanced when there is a mineralogical contrast. Therefore, we dissolution rate constant can be increased to account for an amount of impurities (e.g. clay in a quartz or calcite sandstone) that can accumulate on dissolving contacts. This approach allows large compaction and shear strains within the rock, while allowing examination of local grain-scale heterogeneity. For example, we will describe the effect of pressure solution on the distribution of contact forces magnitudes and orientations. Contact forces in elastic granular packings are inherently heteregeneous, but stress-dependent dissolution tends to equalize them. We apply our model to the simulation of stylolite networks, particularly the interaction of stylolite tips. The stress concentrations from these tips are transmitted through the intervening rock, which can cause elastic strain, brittle damage and frictional sliding. Our model shows that grain rearrangement and compaction rate depend on the surface friction coefficient of grains. Simulation results show the development of shear zones between stylolites, and a high porosity process zone at the tips of stylolites. These features, which have been observed in field studies, are modeled and predicted for the first time. This modeling tool holds a promise to provide many new insights regarding the coupling between pressure solution and brittle deformation, i.e. between mechanical and chemical compaction.
Bubble Continuous Positive Airway Pressure Enhances Lung Volume and Gas Exchange in Preterm Lambs
Pillow, J. Jane; Hillman, Noah; Moss, Timothy J. M.; Polglase, Graeme; Bold, Geoff; Beaumont, Chris; Ikegami, Machiko; Jobe, Alan H.
2007-01-01
Rationale: The technique used to provide continuous positive airway pressure (CPAP) to the newborn may influence lung function and breathing efficiency. Objectives: To compare differences in gas exchange physiology and lung injury resulting from treatment of respiratory distress with either bubble or constant pressure CPAP and to determine if the applied flow influences short-term outcomes. Methods: Lambs (133 d gestation; term is 150 d) born via cesarean section were weighed, intubated, and treated with CPAP for 3 hours. Two groups were treated with 8 L/minute applied flow using the bubble (n = 12) or the constant pressure (n = 12) technique. A third group (n = 10) received the bubble method with 12 L/minute bias flow. Measurements at study completion included arterial blood gases, oxygraphy, capnography, tidal flow, multiple breath washout, lung mechanics, static pressure–volume curves, and bronchoalveolar lavage fluid protein. Measurements and Main Results: Birth weight and arterial gas variables at 15 minutes were comparable. Flow (8 or 12 L/min) did not influence the 3-hour outcomes in the bubble group. Bubble technique was associated with a higher pH, PaO2, oxygen uptake, and area under the flow–volume curve, and a decreased alveolar protein, respiratory quotient, PaCO2, and ventilation inhomogeneity compared with the constant pressure group. Conclusions: Compared with constant pressure technique, bubble CPAP promotes enhanced airway patency during treatment of acute postnatal respiratory disease in preterm lambs and may offer protection against lung injury. PMID:17431223
Periodic Heat Transfer at Small Pressure Fluctuations
NASA Technical Reports Server (NTRS)
Pfriem, H.
1943-01-01
The effect of cyclic gas pressure variations on the periodic heat transfer at a flat wall is theoretically analyzed and the differential equation describing the process and its solution for relatively. Small pressure fluctuations developed, thus explaining the periodic heat cycle between gas and wall surface. The processes for pure harmonic pressure and temperature oscillations, respectively, in the gas space are described by means of a constant heat transfer coefficient and the equally constant phase angle between the appearance of the maximum values of the pressure and heat flow most conveniently expressed mathematically in the form of a complex heat transfer coefficient. Any cyclic pressure oscillations, can be reduced by Fourier analysis to harmonic oscillations, which result in specific, mutual relationships of heat-transfer coefficients and phase angles for the different harmonics.
Vapor pressure measured with inflatable plastic bag
NASA Technical Reports Server (NTRS)
1965-01-01
Deflated plastic bag in a vacuum chamber measures initial low vapor pressures of materials. The bag captures the test sample vapors and visual observation of the vapor-inflated bag under increasing external pressures yields pertinent data.
Chang, Dwayne; Manecksha, Rustom P; Syrrakos, Konstantinos; Lawrentschuk, Nathan
2012-01-01
To investigate the effects of height, external pressure, and bladder fullness on the flow rate in continuous, non-continuous cystoscopy and the automated irrigation fluid pumping system (AIFPS). Each experiment had two 2-litre 0.9% saline bags connected to a continuous, non-continuous cystoscope or AIFPS via irrigation tubing. Other equipment included height-adjustable drip poles, uroflowmetry devices, and model bladders. In Experiment 1, saline bags were elevated to measure the increment in flow rate. In Experiment 2, saline bags were placed under external pressures to evaluate the effect on flow rate. In Experiment 3, flow rate changes in response to variable bladder fullness were measured. Elevating saline bags caused an increase in flow rates, however the increment slowed down beyond a height of 80 cm. Increase in external pressure on saline bags elevated flow rates, but inconsistently. A fuller bladder led to a decrease in flow rates. In all experiments, the AIFPS posted consistent flow rates. Traditional irrigation systems were susceptible to changes in height of irrigation solution, external pressure application, and bladder fullness thus creating inconsistent flow rates. The AIFPS produced consistent flow rates and was not affected by any of the factors investigated in the study.
NASA Technical Reports Server (NTRS)
Carlson, J. R.; Pendergraft, O. C., Jr.; Burley, J. R., II
1986-01-01
A three-dimensional subsonic aerodynamic panel code (VSAERO) was used to predict the effects of upper and lower external nozzle flap geometry on the external afterbody/nozzle pressure coefficient distributions and external nozzle drag of nonaxisymmetric convergent-divergent exhaust nozzles having parallel external sidewalls installed on a generic twin-engine high performance aircraft model. Nozzle static pressure coefficient distributions along the upper and lower surfaces near the model centerline and near the outer edges (corner) of the two surfaces were calculated, and nozzle drag was predicted using these surface pressure distributions. A comparison between the theoretical predictions and experimental wind tunnel data is made to evaluate the utility of the code in calculating the flow about these types of non-axisymmetric afterbody configurations. For free-stream Mach numbers of 0.60 and 0.90, the conditions where the flows were attached on the boattails yielded the best comparison between the theoretical predictions and the experimental data. For the Boattail terminal angles of greater than 15 deg., the experimental data for M = 0.60 and 0.90 indicated areas of separated flow, so the theoretical predictions failed to match the experimental data. Even though calculations of regions of separated flows are within the capabilities of the theoretical method, acceptable solutions were not obtained.
Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
Andrew, Matthew; Bijeljic, Branko; Blunt, Martin
2015-01-01
X-ray microtomography was used to image, at a resolution of 6.6 µm, the pore-scale arrangement of residual carbon dioxide ganglia in the pore-space of a carbonate rock at pressures and temperatures representative of typical formations used for CO2 storage. Chemical equilibrium between the CO2, brine and rock phases was maintained using a high pressure high temperature reactor, replicating conditions far away from the injection site. Fluid flow was controlled using high pressure high temperature syringe pumps. To maintain representative in-situ conditions within the micro-CT scanner a carbon fiber high pressure micro-CT coreholder was used. Diffusive CO2 exchange across the confining sleeve from the pore-space of the rock to the confining fluid was prevented by surrounding the core with a triple wrap of aluminum foil. Reconstructed brine contrast was modeled using a polychromatic x-ray source, and brine composition was chosen to maximize the three phase contrast between the two fluids and the rock. Flexible flow lines were used to reduce forces on the sample during image acquisition, potentially causing unwanted sample motion, a major shortcoming in previous techniques. An internal thermocouple, placed directly adjacent to the rock core, coupled with an external flexible heating wrap and a PID controller was used to maintain a constant temperature within the flow cell. Substantial amounts of CO2 were trapped, with a residual saturation of 0.203 ± 0.013, and the sizes of larger volume ganglia obey power law distributions, consistent with percolation theory. PMID:25741751
Anti-control of chaos of single time-scale brushless DC motor.
Ge, Zheng-Ming; Chang, Ching-Ming; Chen, Yen-Sheng
2006-09-15
Anti-control of chaos of single time-scale brushless DC motors is studied in this paper. In order to analyse a variety of periodic and chaotic phenomena, we employ several numerical techniques such as phase portraits, bifurcation diagrams and Lyapunov exponents. Anti-control of chaos can be achieved by adding an external constant term or an external periodic term.
A mathematical model for filtration and macromolecule transport across capillary walls.
Facchini, L; Bellin, A; Toro, E F
2014-07-01
Metabolic substrates, such as oxygen and glucose, are rapidly delivered to the cells of large organisms through filtration across microvessels walls. Modelling this important process is complicated by the strong coupling between flow and transport equations, which are linked through the osmotic pressure induced by the colloidal plasma proteins. The microvessel wall is a composite media with the internal glycocalyx layer exerting a strong sieving effect on macromolecules, with respect to the external layer composed by the endothelial cells. The physiological structure of the microvessel is represented as the superimposition of two membranes with different properties; the inner membrane represents the glycocalyx, while the outer membrane represents the surrounding endothelial cells. Application of the mass conservation principle and thermodynamic considerations lead to a model composed of two coupled second-order ordinary differential equations for the hydrostatic and osmotic pressures, one, expressing volumetric mass conservation and the other, which is non-linear in the unknown osmotic pressure, expressing macromolecules mass conservation. Despite the complexity of the system, the assumption that the properties of the layers are piece-wise constant allows us to obtain analytical solutions for the two pressures. This solution is in agreement with experimental observations, which contrary to common belief, show that flow reversal cannot occur in steady-state conditions unless the hydrostatic pressure in the lumen drops below physiologically plausible values. The observed variations of the volumetric flux and the solute mass flux in case of a significant reduction of the hydrostatic pressure at the lumen are in qualitative agreement with observed variations during detailed experiments reported in the literature. On the other hand, homogenising the microvessel wall into a single-layer membrane with equivalent properties leads to a very different distribution of pressure across the microvessel walls, not consistent with observations. Copyright © 2014 Elsevier Inc. All rights reserved.
On the interaction between the external magnetic field and nanofluid inside a vertical square duct
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Kashif; Ahmad, Shabbir; Ahmad, Shahzad, E-mail: shahzadahmadbzu@gmail.com
In this paper, we numerically study how the external magnetic field influences the flow and thermal characteristics of nanofluid inside a vertical square duct. The flow is considered to be laminar and hydrodynamically as well as thermally developed, whereas the thermal boundary condition of constant heat flux per unit axial length with constant peripheral temperature at any cross section, is assumed. The governing equations are solved using the spectral method and the finite difference method. Excellent comparison is noted in the numerical results given by the two methods but the spectral method is found to be superior in terms ofmore » both efficiency and accuracy. We have noted that the flow reversal due to high Raleigh number may be controlled by applying an external magnetic field of suitable strength. Moreover, the Nusselt number is found to be almost a linear function of the nanoparticle volume fraction parameter, for different values of the Raleigh number and the magnetic parameter.« less
Static-stress analysis of dual-axis confinement vessel
NASA Astrophysics Data System (ADS)
Bultman, D. H.
1992-11-01
This study evaluates the static-pressure containment capability of a 6-ft-diameter, spherical vessel, made of HSLA-100 steel, to be used for high-explosive (HE) containment. The confinement vessel is designed for use with the Dual-Axis Radiographic Hydrotest Facility (DARHT) being developed at Los Alamos National Laboratory. Two sets of openings in the vessel are covered with x-ray transparent covers to allow radiographic imaging of an explosion as it occurs inside the vessel. The confinement vessel is analyzed as a pressure vessel based on the ASME Boiler and Pressure Vessel Code, Section 8, Division 1, and the Welding Research Council Bulletin, WRC-107. Combined stresses resulting from internal pressure and external loads on nozzles are calculated and compared with the allowable stresses for HSLA-100 steel. Results confirm that the shell and nozzles of the confinement vessel are adequately designed to safely contain the maximum residual pressure of 1675 psi that would result from an HE charge of 24.2 kg detonated in a vacuum. Shell stresses at the shell-to-nozzle interface, produced from external loads on the nozzles, were less than 400 psi. The maximum combined stress resulting from the internal pressure plus external loads was 16,070 psi, which is less than half the allowable stress of 42,375 psi for HSLA-100 steel.
Elasticity of methane hydrate phases at high pressure.
Beam, Jennifer; Yang, Jing; Liu, Jin; Liu, Chujie; Lin, Jung-Fu
2016-04-21
Determination of the full elastic constants (cij) of methane hydrates (MHs) at extreme pressure-temperature environments is essential to our understanding of the elastic, thermodynamic, and mechanical properties of methane in MH reservoirs on Earth and icy satellites in the solar system. Here, we have investigated the elastic properties of singe-crystal cubic MH-sI, hexagonal MH-II, and orthorhombic MH-III phases at high pressures in a diamond anvil cell. Brillouin light scattering measurements, together with complimentary equation of state (pressure-density) results from X-ray diffraction and methane site occupancies in MH from Raman spectroscopy, were used to derive elastic constants of MH-sI, MH-II, and MH-III phases at high pressures. Analysis of the elastic constants for MH-sI and MH-II showed intriguing similarities and differences between the phases' compressional wave velocity anisotropy and shear wave velocity anisotropy. Our results show that these high-pressure MH phases can exhibit distinct elastic, thermodynamic, and mechanical properties at relevant environments of their respective natural reservoirs. These results provide new insight into the determination of how much methane exists in MH reservoirs on Earth and on icy satellites elsewhere in the solar system and put constraints on the pressure and temperature conditions of their environment.
ERIC Educational Resources Information Center
Sefcik, Lesley; Bedford, Simon; Czech, Peter; Smith, Judith; Yorke, Jonathan
2018-01-01
External referencing of assessment and students' achievement standards is a growing priority area within higher education, which is being pressured by government requirements to evidence outcome attainment. External referencing benefits stakeholders connected to higher education by helping to assure that assessments and standards within courses…
K 3 Fe(CN) 6 under External Pressure: Dimerization of CN – Coupled with Electron Transfer to Fe(III)
Li, Kuo; Zheng, Haiyan; Wang, Lijuan; ...
2015-09-14
The addition polymerization of charged monomers like C≡C 2– and C≡N– is scarcely seen at ambient conditions but can progress under external pressure with their conductivity significantly enhanced, which expands the research field of polymer science to inorganic salts. Moreover, the reaction pressures of transition metal cyanides like Prussian blue and K 3Fe(CN) 6 are much lower than that of alkali cyanides. To figure out the effect of the transition metal on the reaction, the crystal structure and electronic structure of K 3Fe(CN) 6 under external pressure are investigated by in situ neutron diffraction, in situ X-ray absorption fine structuremore » (XAFS), and neutron pair distribution functions (PDF) up to ~15 GPa. The cyanide anions react following a sequence of approaching–bonding–stabilizing. The Fe(III) brings the cyanides closer which makes the bonding progress at a low pressure (2–4 GPa). At ~8 GPa, an electron transfers from the CN to Fe(III), reduces the charge density on cyanide ions, and stabilizes the reaction product of cyanide. Finally, from this study we can conclude that bringing the monomers closer and reducing their charge density are two effective routes to decrease the reaction pressure, which is important for designing novel pressure induced conductor and excellent electrode materials.« less
Negative pressure wound therapy and external fixation device: a simple way to seal the dressing.
Bulla, Antonio; Farace, Francesco; Uzel, André-Pierre; Casoli, Vincent
2014-07-01
Negative pressure therapy is widely applied to treat lower limb trauma. However, sealing a negative pressure dressing in the presence of an external fixation device may be difficult and time consuming. Therefore, screws, pins, wires, etc, may preclude the vacuum, preventing the plastic drape to perfectly adhere to the foam. To maintain the vacuum, we tried to prevent air leaking around the screws putting bone wax at the junction between the pins and the plastic drape. This solution, in our hands, avoids air leakage and helps maintain vacuum in a fast and inexpensive way.
MedlinePlus Videos and Cool Tools
... health care products or services, or control the information found on external websites. The Hill Foundation is ... health care products or services, or control the information found on external websites. The Hill Foundation is ...
Measurement of Oil-Film Pressures in Journal Bearings under Constant and Variable Loads
NASA Technical Reports Server (NTRS)
Buske, A.; Rolli, W.
1949-01-01
In a study of journal bearings, the measurement of the oil-film strength produces some significant information. A new instrument is described by means of which the pressure of the oil film in bearings (under constant or alternating load) can be measured and recorded. With this device, the pressure distribution in the lubricating film of a bearing bushing was measured (under different operating conditions on a journal bearing) in the pulsator-bearing-testing machine. These tests are described and discussed in the present report.
Integration of a supersonic unsteady aerodynamic code into the NASA FASTEX system
NASA Technical Reports Server (NTRS)
Appa, Kari; Smith, Michael J. C.
1987-01-01
A supersonic unsteady aerodynamic loads prediction method based on the constant pressure method was integrated into the NASA FASTEX system. The updated FASTEX code can be employed for aeroelastic analyses in subsonic and supersonic flow regimes. A brief description of the supersonic constant pressure panel method, as applied to lifting surfaces and body configurations, is followed by a documentation of updates required to incorporate this method in the FASTEX code. Test cases showing correlations of predicted pressure distributions, flutter solutions, and stability derivatives with available data are reported.
Inflatable bladder provides accurate calibration of pressure switch
NASA Technical Reports Server (NTRS)
Smith, N. J.
1965-01-01
Calibration of a pressure switch is accurately checked by a thin-walled circular bladder. It is placed in the pressure switch and applies force to the switch diaphragm when expanded by an external pressure source. The disturbance to the normal operation of the switch is minimal.
Dual-pump CARS of Air in a Heated Pressure Vessel up to 55 Bar and 1300 K
NASA Technical Reports Server (NTRS)
Cantu, Luca; Gallo, Emanuela; Cutler, Andrew D.; Danehy, Paul M.
2014-01-01
Dual-pump Coherent anti-Stokes Raman scattering (CARS) measurements have been performed in a heated pressure vessel at NASA Langley Research Center. Each measurement, consisting of 500 single shot spectra, was recorded at a fixed location in dry air at various pressures and temperatures, in a range of 0.03-55×10(exp 5) Pa and 300-1373 K, where the temperature was varied using an electric heater. The maximum output power of the electric heater limited the combinations of pressures and temperatures that could be obtained. Charts of CARS signal versus temperature (at constant pressure) and signal versus pressure (at constant temperature) are presented and fit with an empirical model to validate the range of capability of the dual-pump CARS technique; averaged spectra at different conditions of pressure and temperature are also shown.
Makarov, Alexey A; Schafer, Wes A; Helmy, Roy
2015-02-17
The market of protein therapeutics is exploding, and characterization methods for proteins are being further developed to understand and explore conformational structures with regards to function and activity. There are several spectroscopic techniques that allow for analyzing protein secondary structure in solution. However, a majority of these techniques need to use purified protein, concentrated enough in the solution to produce a relevant spectrum. In this study, we describe a novel approach which uses ultrahigh pressure liquid chromatography (UHPLC) coupled with mass-spectrometry (MS) to explore compressibility of the secondary structure of proteins under increasing pressure detected by hydrogen-deuterium exchange (HDX). Several model proteins were used for these studies. The studies were conducted with UHPLC in isocratic mode at constant flow rate and temperature. The pressure was modified by a backpressure regulator up to about 1200 bar. It was found that the increase of retention factors upon pressure increase, at constant flow rate and temperature, was based on reduction of the proteins' molecular molar volume. The change in the proteins' molecular molar volume was caused by changes in protein folding, as was revealed by differential deuterium exchange. The degree of protein folding under certain UHPLC conditions can be controlled by pressure, at constant temperature and flow rate. By modifying pressure during UHPLC separation, it was possible to achieve changes in protein folding, which were manifested as changes in the number of labile protons exchanged to deuterons, or vice versa. Moreover, it was demonstrated with bovine insulin that a small difference in the number of protons exchanged to deuterons (based on protein folding under pressure) could be observed between batches obtained from different sources. The use of HDX during UHPLC separation allowed one to examine protein folding by pressure at constant flow rate and temperature in a mixture of sample solution with minimal amounts of sample used for analysis.
Mass transfer equation for proteins in very high-pressure liquid chromatography.
Gritti, Fabrice; Guiochon, Georges
2009-04-01
The mass transfer kinetics of human insulin was investigated on a 50 mm x 2.1 mm column packed with 1.7 microm BEH-C(18) particles, eluted with a water/acetonitrile/trifluoroacetic acid (TFA) (68/32/0.1, v/v/v) solution. The different contributions to the mass transfer kinetics, e.g., those of longitudinal diffusion, eddy dispersion, the film mass transfer resistance, cross-particle diffusivity, adsorption-desorption kinetics, and transcolumn differential sorption, were incorporated into a general mass transfer equation designed to account for the mass transfer kinetics of proteins under high pressure. More specifically, this equation includes the effects of pore size exclusion, pressure, and temperature on the band broadening of a protein. The flow rate was first increased from 0.001 to 0.250 mL/min, the pressure drop increasing from 2 to 298 bar, and the column being placed in stagnant air at 296.5 K, in order to determine the effective diffusivity of insulin through the porous particles, the mass transfer rate constants, and the adsorption equilibrium constant in the low-pressure range. Then, the column inlet pressure was increased by using capillary flow restrictors downstream the column, at the constant flow rate of 0.03 mL/min. The column temperature was kept uniform by immersing the column in a circulating water bath thermostatted at 298.7 and 323.15 K, successively. The results showed that the surface diffusion coefficient of insulin decreases faster than its bulk diffusion coefficient with increasing average column pressure. This is consistent with the adsorption energy of insulin onto the BEH-C(18) surface increasing strongly with increasing pressure. In contrast, given the precision of the height equivalent to a theoretical plate (HETP) measurement (+/-12%), the adsorption kinetics of insulin appears to be rather independent of the pressure. On average, the adsorption rate constant of insulin is doubled from about 40 to 80 s(-1) when the temperature increases from 298.7 to 323.15 K.
Cosmological constant is a conserved charge
NASA Astrophysics Data System (ADS)
Chernyavsky, Dmitry; Hajian, Kamal
2018-06-01
Cosmological constant can always be considered as the on-shell value of a top form in gravitational theories. The top form is the field strength of a gauge field, and the theory enjoys a gauge symmetry. We show that cosmological constant is the charge of the global part of the gauge symmetry, and is conserved irrespective of the dynamics of the metric and other fields. In addition, we introduce its conjugate chemical potential, and prove the generalized first law of thermodynamics which includes variation of cosmological constant as a conserved charge. We discuss how our new term in the first law is related to the volume–pressure term. In parallel with the seminal Wald entropy, this analysis suggests that pressure can also be considered as a conserved charge.
Implantable device for in-vivo intracranial and cerebrospinal fluid pressure monitoring
Ericson, Milton N.; McKnight, Timothy E.; Smith, Stephen F.; Hylton, James O.
2003-01-01
The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.
Tan, Ee Lim; DeRouin, Andrew J.; Pereles, Brandon D.; Ong, Keat Ghee
2011-01-01
A passive and wireless sensor was developed for monitoring pressure in vivo. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is an airtight chamber sealed with an elastic pressure membrane. A strip of magnetically-soft material is attached to the bottom of the chamber and a permanent magnet strip is embedded inside the membrane. Under the excitation of an externally applied AC magnetic field, the magnetically-soft strip produces a higher-order magnetic signature that can be remotely detected with an external receiving coil. As ambient pressure varies, the pressure membrane deflects, altering the separation distance between the magnetically-soft strip and the permanent magnet. This shifts the higher-order harmonic signal, allowing for detection of pressure change as a function of harmonic shifting. The wireless, passive nature of this sensor technology allows for continuous long-term pressure monitoring, particularly useful for biomedical applications such as monitoring pressure in aneurysm sac and sphincter of Oddi. In addition to demonstrating its pressure sensing capability, an animal model was used to investigate the efficacy and feasibility of the pressure sensor in a biological environment. PMID:25585564
MHD Stability in Compact Stellarators
NASA Astrophysics Data System (ADS)
Fu, Guoyong
1999-11-01
A key issue for current carrying compact stellarators(S.P. Hirshman et al., "Physics of compact stellarators", Phys. Plasmas 6, 1858 (1999).) is the stability of ideal MHD modes. We present recent stability results of external kink modes, ballooning mode, and vertical modes in Quasi-axisymmetric Stellarators (QAS)( A. Reiman et al, "Physics issue in the design of a high beta Quasi-Axisymmetric Stellarator" the 17th IAEA Fusion Energy conference, (Yokohama, Japan, October 1998), Paper ICP/06.) as well as Quasi-Omnigeneous Stellarators (QOS)^2. The 3D stability code Terpsichore(W. A. Cooper et al., Phys. Plasmas 3, 275 (1996)) is used in this study. The vertical stability in a current carrying stellarator is studied for the first time. The vertical mode is found to be stabilized by externally generated poloidal flux(G.Y. Fu et al., "Stability of vertical mode in a current carrying stellarator"., to be submitted). Physically, this is because the external poloidal flux enhances the field line bending energy relative to the current drive term in the MHD energy principle, δ W. A simple stability criteria is derived in the limit of large aspect ratio and constant current density. For wall at infinite distance from the plasma, the amount of external flux needed for stabilization is given by f=(κ^2-κ)/(κ^2+1) where κ is the axisymmetric elongation and f is the fraction of the external rotational transform at the plasma edge. A systematic parameter study shows that the external kink in QAS can be stabilized at high beta ( ~ 5%) without a conducting wall by combination of edge magnetic shear and 3D shaping(G. Y. Fu et al., "MHD stability calculations of high-beta Quasi-Axisymmetric Stellarators", the 17th IAEA Fusion Energy conference, (Yokohama, Japan, October 1998), paper THP1/07.). The optimal shaping is obtained by using an optimizer with kink stability included in its objective function. The physics mechanism for the kink modes is studied by examining relative contributions of individual terms in δ W. It is found the external kinks are mainly driven by the parallel current. The pressure contributes significantly to the overall drive through the curvature term and the Pfirsch-Schluter current. These results demonstrate potential of QAS and QOS for disruption-free operations at high-beta without a close-fitting conducting wall and feedback stabilization.
NASA Technical Reports Server (NTRS)
Cantrell, John H.
2014-01-01
The second and third-order Brugger elastic constants are obtained for liquids and ideal gases having an initial hydrostatic pressure p(sub 1). For liquids the second-order elastic constants are C(sub 11) = A + p(sub 1), C(sub 12) = A -- p(sub 1), and the third-order constants are C(sub 111) = --(B + 5A + 3p(sub 1)), C(sub 112) = --(B + A -- p(sub 1)), and C(sub 123) = A -- B -- p1, where A and B are the Beyer expansion coefficients in the liquid equation of state. For ideal gases the second order constants are C(sub 11) = p(sub 1)gamma + p9sub 1), C(sub 12) = p(sub 1)gamma -- p(sub 1), and the third-order constants are C(sub 111) = p(sub 1)(gamma(2) + 4gamma + 3), C(sub 112) = --p(sub 1)(gamma(2) -- 1), and C(sub 123) = --p(sub 1) (gamma(2) -- 2gamma + 1), where gamma is the ratio of specific heats. The inequality of C(sub 11) and C(sub 12) results in a nonzero shear constant C(sub 44) = (1/2)(C(sub 11) C(sub 12)) = p(sub 1) for both liquids and gases. For water at standard temperature and pressure the ratio of terms p1/A contributing to the second-order constants is approximately 4.3 x 10(-5). For atmospheric gases the ratio of corresponding terms is approximately 0.7. Analytical expressions that include initial stresses are derived for the material 'nonlinearity parameters' associated with harmonic generation and acoustoelasticity for fluids and solids of arbitrary crystal symmetry. The expressions are used to validate the relationships for the elastic constants of fluids.
Pressure sores–a constant problem for plegic patients and a permanent challenge for plastic surgery
Marinescu, S; Florescu, IP; Jecan, C
2010-01-01
Pressure sores–a constant problem for plegic patients and a permanent challenge for plastic surgery Pressure sores can be defined as lesions caused by unrelieved pressure resulting in damage of the underlying tissue. They represent a common problem in the pathology of plegic patients and, plastic surgery has a significant role in their treatment. Pressure sores occur over bony prominences and so, they are most commonly seen at the sacrum and trochanters in paralyzed patients and at ischium for the patients who sit in a wheelchair for a long time. For these patients, surgical treatment is very important because on one hand, it stops the loss of nutrients and proteins at the site of the pressure sore, and on the other hand, it permits the initiation of neuromuscular recuperation treatment much faster. PMID:20968200
The efficiency of combustion turbines with constant-pressure combustion
NASA Technical Reports Server (NTRS)
Piening, Werner
1941-01-01
Of the two fundamental cycles employed in combustion turbines, namely, the explosion (or constant-volume) cycle and the constant-pressure cycle, the latter is considered more in detail and its efficiency is derived with the aid of the cycle diagrams for the several cases with adiabatic and isothermal compression and expansion strokes and with and without utilization of the exhaust heat. Account is also taken of the separate efficiencies of the turbine and compressor and of the pressure losses and heat transfer in the piping. The results show that without the utilization of the exhaust heat the efficiencies for the two cases of adiabatic and isothermal compression is offset by the increase in the heat supplied. It may be seen from the curves that it is necessary to attain separate efficiencies of at least 80 percent in order for useful results to be obtained. There is further shown the considerable effect on the efficiency of pressure losses in piping or heat exchangers.
Pressure and temperature dependences of the reaction of OH with nitric acid
NASA Technical Reports Server (NTRS)
Stachnik, R. A.; Molina, L. T.; Molina, M. J.
1986-01-01
Rate constants for the reaction of OH with HNO3 have been measured by using a laser flash photolysis resonance absorption technique at 298 and 248 K in the presence of 10-730 Torr of He, N2, and SF6. A dependence on total pressure was observed with rate constant values increasing at 298 K from 1.11 x 10 to the -13th cu cm/molecule/s at 10 Torr to 1.45 x 10 to the -13th cu cm/molecule/s at 730 Torr, and at 248 K from 1.87 x 10 to the -13th cu cm/molecule/s at 10 Torr to 3.07 x 10 to the -13th cu cm/molecule/s at 730 Torr with helium as the diluent gas. Falloff behavior occurred at lower pressures with SF6 or N2 as the diluent gas. Extrapolated zero pressure rate constants were determined and correspond to an Arrhenius activation energy of E/R = -710 K.
External Squeeze-Film Damper For Hydrostatic Bearing
NASA Technical Reports Server (NTRS)
Buckmann, Paul S.
1992-01-01
External squeeze-film damping device suppresses vibrations of rapidly turning shaft supported by pivoted-pad hydrostatic bearing in high-pressure/high-power-density turbomachine. Stacked disks provide damping and clearance for alignment.
Buckling of Thin Cylindrical Shell Subject to Uniform External Pressure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forasassi, G.; Lo Frano, R.
2006-07-01
The buckling of cylindrical shells under uniform external pressure loading has been widely investigated. In general, when tubes are subjected to external pressure, collapse is initiated by yielding, but interaction with instability is significant, in that imperfections associated with fabrication of shells reduce the load bearing capacity by a significant amount even when thickness is considerable. A specific buckling analysis is used to predict collapse failure of long pressure vessels and pipelines when they are subjected to external over-pressure. The problem of buckling for variable load conditions is relevant for the optimisation of several Nuclear Power Plant applications as, formore » instance, the IRIS (International Reactor Innovative and Secure) LWR integrated Steam Generator (SG) tubes. In this paper, we consider in addition to the usual assumptions of thin shell, homogeneous and isotropic material, also the tube geometric imperfections and plastic deformations that may affect the limit load. When all those conditions are considered at present, a complete theoretical analysis was not founding the literature. At Pisa University a research activity is being carried out on the buckling of thin walled metal specimen, with reference to several geometries and two different stainless steel materials. A test equipment (with the necessary data acquisition facility), suitable for carrying out many test on this issue, as well as numerical models implemented on the MARC FEM code, were set up. In this report, the results of the performed analyses of critical pressure load determination with different numerical and experimental approaches are presented. The numerical results obtained are compared with the experimental results, for the same geometry and loading conditions, showing a good agreement between these two approaches. (authors)« less
Titiyal, Jeewan S; Kaur, Manpreet; Falera, Ruchita; Jose, Cijin P; Sharma, Namrata
2016-04-01
To evaluate the time to donor lenticule apposition in cases of Descemet stripping automated endothelial keratoplasty (DSAEK) using microscope-integrated intraoperative optical coherence tomography (iOCT). Thirty eyes of 27 patients planned to undergo Descemet stripping automated endothelial keratoplasty were enrolled in this prospective study. In group I (n = 10), continuous intracameral positive pressure was maintained for 8 minutes. In group II (n = 10) and group III (n = 10), external corneal massage was initiated simultaneously with positive intracameral air pressure. The external corneal massage was continued till complete resolution of interface fluid; the positive intracameral pressure was maintained for 8 minutes in group II and for 5 minutes in group III. The host-donor relationship was continuously monitored with the iOCT. The main outcome measure was time to complete donor lenticule apposition. In group I, the interface fluid persisted after 8 minutes of positive intracameral pressure in all eyes (10/10); hence an external corneal massage was required to achieve optimal donor adherence. In groups II and III, all eyes (20/20) had complete resolution of the interface fluid at the end of 3 minutes. In 100% of the eyes (30/30), the grafts were attached after anterior chamber decompression as seen on the iOCT. In all cases, the donor lenticules were adhered in the postoperative period. iOCT helps in understanding that the donor lenticule is well apposed within 1 to 3 minutes with the technique of simultaneous positive intracameral pressure and external corneal massage. This knowledge minimizes the waiting time for graft apposition and prevents prolonged intraocular pressure elevation.
Pressure distribution over an NACA 23012 airfoil with an NACA 23012 external-airfoil flap
NASA Technical Reports Server (NTRS)
Wenzinger, Carl J
1938-01-01
Report presents the results of pressure-distribution tests of an NACA 23012 airfoil with an NACA 23012 external airfoil flap made in the 7 by 10-foot wind tunnel. The pressures were measured on the upper and lower surfaces at one chord section on both the main airfoil and on the flap for several different flap deflections and at several angles of attack. A test installation was used in which the airfoil was mounted horizontally in the wind tunnel between vertical end planes so that two-dimensional flow was approximated. The data are presented in the form of pressure-distribution diagrams and as graphs of calculated coefficients for the airfoil-and-flap combination and for the flap alone.
Razus, Domnina; Brinzea, Venera; Mitu, Maria; Oancea, Dumitru
2010-02-15
An experimental study on pressure evolution during closed vessel explosions of propane-air mixtures was performed, for systems with various initial concentrations and pressures ([C(3)H(8)]=2.50-6.20 vol.%, p(0)=0.3-1.2 bar). The explosion pressures and explosion times were measured in a spherical vessel (Phi=10 cm), at various initial temperatures (T(0)=298-423 K) and in a cylindrical vessel (Phi=10 cm; h=15 cm), at ambient initial temperature. The experimental values of explosion pressures are examined against literature values and compared to adiabatic explosion pressures, computed by assuming chemical equilibrium within the flame front. The influence of initial pressure, initial temperature and fuel concentration on explosion pressures and explosion times are discussed. At constant temperature and fuel/oxygen ratio, the explosion pressures are linear functions of total initial pressure, as reported for other fuel-air mixtures. At constant initial pressure and composition, both the measured and calculated (adiabatic) explosion pressures are linear functions of reciprocal value of initial temperature. Such correlations are extremely useful for predicting the explosion pressures of flammable mixtures at elevated temperatures and/or pressures, when direct measurements are not available.
14 CFR 25.365 - Pressurized compartment loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Pressurized compartment loads. For airplanes with one or more pressurized compartments the following apply: (a... differential loads from zero up to the maximum relief valve setting. (b) The external pressure distribution in... zero up to the maximum allowed during landing. (d) The airplane structure must be designed to be able...
Spacecraft compartment venting
NASA Astrophysics Data System (ADS)
Scialdone, John J.
1998-10-01
At various times, concerns have been expressed that rapid decompressions of compartments of gas pockets and thermal blankets during spacecraft launches may have caused pressure differentials across their walls sufficient to cause minor structural failures, separations of adhesively-joined parts, ballooning, and flapping of blankets. This paper presents a close form equation expressing the expected pressure differentials across the walls of a compartment as a function of the external to the volume pressure drops, the pressure at which the rates occur and the vent capability of the compartment. The pressure profiles measured inside the shrouds of several spacecraft propelled by several vehicles and some profiles obtained from ground vacuum systems have been included. The equation can be used to design the appropriate vent, which will preclude excessive pressure differentials. Precautions and needed approaches for the evaluations of the expected pressures have been indicated. Methods to make a rapid assessment of the response of the compartment to rapid external pressure drops have been discussed. These are based on the evaluation of the compartment vent flow conductance, the volume and the length of time during which the rapid pressure drop occurs.
Spacecraft Compartment Venting
NASA Technical Reports Server (NTRS)
Scialdone, John J.
1998-01-01
At various time concerns have been expressed that rapid decompressions of compartments of gas pockets and thermal blankets during spacecraft launches may have caused pressure differentials across their walls sufficient to cause minor structural failures, separations of adhesively-joined parts, ballooning, and flapping of blankets. This paper presents a close form equation expressing the expected pressure differentials across the walls of a compartment as a function of the external to the volume pressure drops, the pressure at which the rates occur and the vent capability of the compartment. The pressure profiles measured inside the shrouds of several spacecraft propelled by several vehicles and some profiles obtained from ground vacuum systems have been included. The equation can be used to design the appropriate vent, which will preclude excessive pressure differentials. Precautions and needed approaches for the evaluations of the expected pressures have been indicated. Methods to make a rapid assessment of the response of the compartment to rapid external pressure drops have been discussed. These are based on the evaluation of the compartment vent flow conductance, the volume and the length of time during which the rapid pressure drop occurs.
A Systems Analysis of Strike Naval Aviation Training
2013-06-01
from external nodes (yellow) and flows through the model design (gray nodes). Arrows represent information flow direction and identify what...multiple times need to be established as external functions accessible by all subroutines • Variables and constants must be defined up-front, and...Downloaded Figure 37. Blocks In Figure 38, proficiency threshold breeches are highlighted to indicate when the resulting skill proficiency drops below the
Methodology for the Design of Streamline-Traced External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2014-01-01
A design methodology based on streamline-tracing is discussed for the design of external-compression, supersonic inlets for flight below Mach 2.0. The methodology establishes a supersonic compression surface and capture cross-section by tracing streamlines through an axisymmetric Busemann flowfield. The compression system of shock and Mach waves is altered through modifications to the leading edge and shoulder of the compression surface. An external terminal shock is established to create subsonic flow which is diffused in the subsonic diffuser. The design methodology was implemented into the SUPIN inlet design tool. SUPIN uses specified design factors to design the inlets and computes the inlet performance, which includes the flow rates, total pressure recovery, and wave drag. A design study was conducted using SUPIN and the Wind-US computational fluid dynamics code to design and analyze the properties of two streamline-traced, external-compression (STEX) supersonic inlets for Mach 1.6 freestream conditions. The STEX inlets were compared to axisymmetric pitot, two-dimensional, and axisymmetric spike inlets. The STEX inlets had slightly lower total pressure recovery and higher levels of total pressure distortion than the axisymmetric spike inlet. The cowl wave drag coefficients of the STEX inlets were 20% of those for the axisymmetric spike inlet. The STEX inlets had external sound pressures that were 37% of those of the axisymmetric spike inlet, which may result in lower adverse sonic boom characteristics. The flexibility of the shape of the capture cross-section may result in benefits for the integration of STEX inlets with aircraft.
NASA Astrophysics Data System (ADS)
Wenger, Oliver S.; Salley, G. Mackay; Valiente, Rafael; Güdel, Hans U.
2002-06-01
We present a study of upconversion materials and processes under external hydrostatic pressure. The near-infrared to visible photon upconversion properties of Ti2+-doped NaCl and Ni2+-doped CsCdCl3 at 15 K are studied as a function of external hydrostatic pressure. It is found that in Ti2+:NaCl pressure can be used to switch on an efficient upconversion mechanism, which is inactive at ambient pressure, leading to an order-of-magnitude enhancement of the overall upconversion efficiency of this material. For Ni2+:CsCdCl3 it is demonstrated that upconversion luminescence excitation spectroscopy can be used to study the pressure dependence of excited state absorption transitions. The results demonstrate the ability to tune upconversion properties by altering the local crystal field of active ions, in addition to probing the pressure dependence of excited state absorption transitions via upconversion spectroscopy.
Spool-Valve Pressure-Difference Regulator
NASA Technical Reports Server (NTRS)
Grasso, A. P.
1983-01-01
Valves maintain preset pressure difference between gas flows. Two spool valves connected by shaft move back and forth in response to changes in pressure in oxygen and hydrogen chambers. Spool-valve assembly acts to restore pressures to preset difference. By eliminating diaphragms, pressure exerted directly on external end of spool valve; however, forces and therefore sensitivity of assembly are reduced.
Diffusion coalescence in НоBa2Cu3O7-x single crystals under the application of hydrostatic pressure
NASA Astrophysics Data System (ADS)
Boiko, Y. I.; Bogdanov, V. V.; Vovk, R. V.; Khadzhaj, G. Ya; Kamchatnaya, S. N.; Goulatis, I. L.; Chroneos, A.
2017-09-01
Experimental results on the effect of external hydrostatic pressure up to 5 kbar on the ρ(T) dependence in the ab plane of HoBa2Cu3O7-x single crystals (x ≈ 0.35) in the temperature range from 300 K to the superconducting transition temperature T c are presented and discussed. It was established that the application of external hydrostatic pressure P = 5 kbar significantly intensified the process of diffusion coalescence of oxygen clusters, causing the growth of their average size. This leads to an increase in the number of negative U-centers, the presence of which results to the appearance of a phase capable of generating paired carriers of electric charge and, correspondingly, characterized by a higher transition temperature T c. Employing this hypothesis that concerns the mechanism of the diffusion coalescence of oxygen clusters, the change in the form of the temperature and time dependences of the electrical resistivity under the application of external hydrostatic pressure is discussed.
CN radical reactions with hydrogen cyanide and cyanogen - Comparison of theory and experiment
NASA Technical Reports Server (NTRS)
Yang, D. L.; Yu, T.; Lin, M. C.; Melius, C. F.
1992-01-01
The method of laser photolysis/laser-induced fluorescence is used to obtain absolute rate constants for CN radical reactions with HCN and C2N2. The rate constants were found to be temperature-dependent in the range 300-740 K and pressure independent in the range 100-600 Torr. Rice-Remsperger-Kassel-Marcus theory for both reactions employing the transition state parameters obtained by the BAC-MP4 method are made. These calculations yielded reasonable results for the CN + HCN reaction, predicting both the temperature dependence and pressure independence. No pressure effect was observed in the pressure range 100-1000 Torr at temperatures below 900 K, confirming the experimental results.
Pressure compensated flow control valve
Minteer, Daniel J.
1999-01-01
The invention is an air flow control valve which is capable of maintaining a constant flow at the outlet despite changes in the inlet or outlet pressure. The device consists of a shell assembly with an inlet chamber and outlet chamber separated by a separation plate. The chambers are connected by an orifice. Also located within the inlet chamber is a port controller assembly. The port controller assembly consists of a differential pressure plate and port cap affixed thereon. The cap is able to slide in and out of the orifice separating the inlet and outlet chambers. When the pressure differential is sufficient, the differential pressure plate rises or falls to maintain a constant air flow. Movement of the port controller assembly does not require the use of seals, diaphragms, tight tolerances, bushings, bearings, hinges, guides, or lubricants.
The Oxidation Rate of SiC in High Pressure Water Vapor Environments
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Robinson, R. Craig
1999-01-01
CVD SiC and sintered alpha-SiC samples were exposed at 1316 C in a high pressure burner rig at total pressures of 5.7, 15, and 25 atm for times up to 100h. Variations in sample emittance for the first nine hours of exposure were used to determine the thickness of the silica scale as a function of time. After accounting for volatility of silica in water vapor, the parabolic rate constants for Sic in water vapor pressures of 0.7, 1.8 and 3.1 atm were determined. The dependence of the parabolic rate constant on the water vapor pressure yielded a power law exponent of one. Silica growth on Sic is therefore limited by transport of molecular water vapor through the silica scale.
Accommodations for earth-viewing payloads on the international space station
NASA Astrophysics Data System (ADS)
Park, B.; Eppler, D. B.
The design of the International Space Station (ISS) includes payload locations that are external to the pressurized environment. These external or attached payload accommodation locations will allow direct access to the space environment at the ISS orbit and direct viewing of the earth and space. NASA sponsored payloads will have access to several different types of standard external locations; the S3 Truss Sites, the Columbus External Payload Facility (EPF), and the Japanese Experiment Module Exposed Facility (JEM-EF). As the ISS Program develops, it may also be possible to locate external payloads at the P3 Truss Sites or at non-standard locations similar to the handrail-attached payloads that were flown during the MIR Program. Earth-viewing payloads may also be located within the pressurized volume of the US Lab in the Window Observational Research Facility (WORF). Payload accommodations at each of the locations will be described, as well as transport to and retrieval from the site.
Rey, Marcel; Fernández-Rodríguez, Miguel Ángel; Steinacher, Mathias; Scheidegger, Laura; Geisel, Karen; Richtering, Walter; Squires, Todd M; Isa, Lucio
2016-04-21
We have studied the complete two-dimensional phase diagram of a core-shell microgel-laden fluid interface by synchronizing its compression with the deposition of the interfacial monolayer. Applying a new protocol, different positions on the substrate correspond to different values of the monolayer surface pressure and specific area. Analyzing the microstructure of the deposited monolayers, we discovered an isostructural solid-solid phase transition between two crystalline phases with the same hexagonal symmetry, but with two different lattice constants. The two phases corresponded to shell-shell and core-core inter-particle contacts, respectively; with increasing surface pressure the former mechanically failed enabling the particle cores to come into contact. In the phase-transition region, clusters of particles in core-core contacts nucleate, melting the surrounding shell-shell crystal, until the whole monolayer moves into the second phase. We furthermore measured the interfacial rheology of the monolayers as a function of the surface pressure using an interfacial microdisk rheometer. The interfaces always showed a strong elastic response, with a dip in the shear elastic modulus in correspondence with the melting of the shell-shell phase, followed by a steep increase upon the formation of a percolating network of the core-core contacts. These results demonstrate that the core-shell nature of the particles leads to a rich mechanical and structural behavior that can be externally tuned by compressing the interface, indicating new routes for applications, e.g. in surface patterning or emulsion stabilization.
Daar, David A; Wirth, Garrett A; Evans, Gregory Rd; Carmean, Melissa; Gordon, Ian L
2017-02-01
Current embodiments of negative pressure wound therapy (NPWT) create a hermetically sealed chamber at the surface of the body using polyurethane foam connected to a vacuum pump, which is then covered by a flexible adhesive drape. Commercially available NPWT systems routinely use flexible polyethylene films that have a sticky side, coated with the same acrylate adhesives used in other medical devices such as ECG leads and grounding pads. Severe reactions to the acrylate adhesives in these other devices, although uncommon, have been reported. We describe the case of a 63-year-old woman with an intractable leg ulcer resulting from external-beam radiotherapy (XRT). Treatment with a standard commercial NPWT system induced severe inflammation of the skin in direct contact with drape adhesive. We successfully administered prolonged, outpatient NPWT to the patient using an alternative method (first described by Bagautdinov in 1986), using plain polyethylene film and petrolatum. The necessary hermetic seal is achieved by smearing the skin with petrolatum before applying the polyethylene film and activating the vacuum pump. The Bagautdinov method is a practical solution to the problem of adapting NPWT to patients with contact sensitivity or skin tears related to the adhesive compounds in the flexible drapes. Its use of a circumferential elastic wrap to maintain constant pressure on the seal probably limits the Bagautdinov technique to the extremities. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Base Heating Sensitivity Study for a 4-Cluster Rocket Motor Configuration in Supersonic Freestream
NASA Technical Reports Server (NTRS)
Mehta, Manish; Canabal, Francisco; Tashakkor, Scott B.; Smith, Sheldon D.
2011-01-01
In support of launch vehicle base heating and pressure prediction efforts using the Loci-CHEM Navier-Stokes computational fluid dynamics solver, 35 numerical simulations of the NASA TND-1093 wind tunnel test have been modeled and analyzed. This test article is composed of four JP-4/LOX 500 lbf rocket motors exhausting into a Mach 2 - 3.5 wind tunnel at various ambient pressure conditions. These water-cooled motors are attached to a base plate of a standard missile forebody. We explore the base heating profiles for fully coupled finite-rate chemistry simulations, one-way coupled RAMP (Reacting And Multiphase Program using Method of Characteristics)-BLIMPJ (Boundary Layer Integral Matrix Program - Jet Version) derived solutions and variable and constant specific heat ratio frozen flow simulations. Variations in turbulence models, temperature boundary conditions and thermodynamic properties of the plume have been investigated at two ambient pressure conditions: 255 lb/sq ft (simulated low altitude) and 35 lb/sq ft (simulated high altitude). It is observed that the convective base heat flux and base temperature are most sensitive to the nozzle inner wall thermal boundary layer profile which is dependent on the wall temperature, boundary layer s specific energy and chemical reactions. Recovery shock dynamics and afterburning significantly influences convective base heating. Turbulence models and external nozzle wall thermal boundary layer profiles show less sensitivity to base heating characteristics. Base heating rates are validated for the highest fidelity solutions which show an agreement within +/-10% with respect to test data.
Simulating cosmic ray physics on a moving mesh
NASA Astrophysics Data System (ADS)
Pfrommer, C.; Pakmor, R.; Schaal, K.; Simpson, C. M.; Springel, V.
2017-03-01
We discuss new methods to integrate the cosmic ray (CR) evolution equations coupled to magnetohydrodynamics on an unstructured moving mesh, as realized in the massively parallel AREPO code for cosmological simulations. We account for diffusive shock acceleration of CRs at resolved shocks and at supernova remnants in the interstellar medium (ISM) and follow the advective CR transport within the magnetized plasma, as well as anisotropic diffusive transport of CRs along the local magnetic field. CR losses are included in terms of Coulomb and hadronic interactions with the thermal plasma. We demonstrate the accuracy of our formalism for CR acceleration at shocks through simulations of plane-parallel shock tubes that are compared to newly derived exact solutions of the Riemann shock-tube problem with CR acceleration. We find that the increased compressibility of the post-shock plasma due to the produced CRs decreases the shock speed. However, CR acceleration at spherically expanding blast waves does not significantly break the self-similarity of the Sedov-Taylor solution; the resulting modifications can be approximated by a suitably adjusted, but constant adiabatic index. In first applications of the new CR formalism to simulations of isolated galaxies and cosmic structure formation, we find that CRs add an important pressure component to the ISM that increases the vertical scaleheight of disc galaxies and thus reduces the star formation rate. Strong external structure formation shocks inject CRs into the gas, but the relative pressure of this component decreases towards halo centres as adiabatic compression favours the thermal over the CR pressure.
Experimental flow studies in glaucoma drainage device development.
2001-10-01
(I) To examine whether small holes produced by 248 nm excimer laser ablation in a polymer substrate could consistently produce a pressure drop in the desired target range (5-15 mm Hg) at physiological aqueous flow rates for use as an internal flow restrictor in a glaucoma drainage device, and (ii) to investigate whether external leakage could be reduced in comparison with conventional tube and plate glaucoma drainage devices by redesigning the exterior cross sectional shape of the portion contained within the sclerocorneal tunnel. Single holes with target diameters of 10 microm, 15 microm, 20 microm, and 25 microm were drilled using a 248 nm excimer laser in sample discs (n=6 at each diameter) punched from a 75 microm thick polyimide sheet. Sample discs were tested in a flow rig designed to measure the pressure drop across the discs. Using filtered, degassed water at a flow rate of 1.4 microl/min repeated flow measurements were taken (n=6) for each disc. After flow testing, all discs were imaged using a scanning electron microscope and the dimensions of each hole were derived using image analysis software. In the external leakage study, corneoscleral buttons (n=13) were prepared from cadaver pig eyes and mounted on an artificial anterior chamber infused with Tyrode solution. After the pressure had stabilised, standard occluded silicone tube implants were inserted through 23 gauge needle stab incisions at the limbus. These were compared against prototype PMMA implants with a novel shape profile inserted through 1.15 mm width microvitreoretinal (MVR) stab incisions at the limbus. The infusion rate was maintained and a second pressure measurement was taken when the pressure had stabilised. The difference between the first and second pressure measurement was then compared, as an index of external leakage. Ablated tubes were found to have a near perfect circular outline on both the entry and exit side. The observed pressure drops across the ablated sample discs at each target diameter were as follows: 10 microm, mean 25.66 (SD 4.9) mm Hg; 15 microm, 6.7 (1.15); 20 microm, 1.66 (1.07); and 25 microm, <0.1 mm Hg. A strong correlation was observed between observed pressure drops and those predicted by Poiseuille's formula (R(2) =0.996). Target ablations of 15 microm diameter produced tubes that consistently achieved a pressure drop within the desired range (5-15 mm Hg). In the external leakage study, preinsertion pressures (mm Hg; mean (SD)) were 19.00 (4.3) (conventional method) and 20.00 (3.9) (new technique with PMMA prototypes). Post-insertion pressures were significantly reduced (10.40 (7.7); p<0.01) for the conventional technique and were essentially unchanged for the new technique (18.80 (4.9); p>0.1). It was shown that it is possible, in principle, to control the dimensions of a manufactured tubular lumen in a glaucoma drainage device accurately enough to provide consistent protection from hypotony in the early period after glaucoma filtration surgery. By redesigning the external profile of glaucoma drainage device and incision technique, it was also shown that it is possible to eliminate uncontrolled external leakage.
NASA Astrophysics Data System (ADS)
Smith, Robert William
Many electrically driven thermoacoustic refrigerators have employed corrugated metal bellows to couple work from an electro-mechanical transducer to the working fluid typically. An alternative bellows structure to mediate this power transfer is proposed: a laminated hollow cylinder comprised of alternating layers of rubber and metal 'hoop-stack'. Fatigue and visoelastic power dissipation in the rubber are critical considerations; strain energy density plays a role in both. Optimal aspect ratios for a rectangle corss-section in the rubber, for given values of bellows axial strain and oscillatory pressure loads are discussed. Comparisons of tearing energies estimated from known load cases and those obtained by finite element analysis for candidate dimensions are presented. The metal layers of bellows are subject to an out-of-plane buckling instability for the case of external pressure loading; failure of this type was experimentally observed. The proposed structure also exhibits column instability when subject to internal pressure, as do metal bellows. For hoop-stack bellows, shear deflection cannot be ignored and this leads to column instability for both internal and external pressures, the latter being analogous to the case of tension buckling of a beam. During prototype bellows testing, transverse modes of vibration are believed to have been excited parametrically as a consequence of the oscillatory pressures. Some operating frequencies of interest in this study lie above the cut-on frequency at which Timoshenko beam theory (TBT) predicts multiple phase speeds; it is shown that TBT fails to accurately predict both mode shapes and resonance frequencies in this regime. TBT is also shown to predict multiple phase speeds in the presence of axial tension, or external pressures, at magnitudes of interest in this study, over the entire frequency spectrum. For modes below cut-on absent a pressure differential (or equivalently, axial load) TBT predicts decreasing resonance frequencies for both internal external static pressure, and converges on known, valid static buckling solutions. Parametric stability in the presence of oscillatory pressure is discussed for such modes; periodic solutions to the Whittaker-Hill equation are pursued to illustrate the shape of the parametric instability regions, and contrasted with results of the more well-known Mathieu equation.
Nonlinear aspects of infrasonic pressure transfer into the perilymph.
Krukowski, B; Carlborg, B; Densert, O
1980-06-01
The perilymphatic pressure was studied in response to various low frequency pressure changes in the ear canal. The pressure transfer was analysed and found to be nonlinear in many aspects. The pressure response was found to contain two time constants representing the inner ear pressure regulating mechanisms. The time constants showed an asymmetry in response to positive and negative going inputs--the effects to some extent proportional to input levels. Further nonlinearities were found when infrasonic sine waves were applied to the ear. Harmonic distortion and modulation appeared. When short bursts of infrasound were introduced a clear d.c. shift was observed as a consequence of an asymmetry in the response to positive and negative going pressure inputs. A temporary change in mean perilymphatic pressure was thus achieved and continued throughout the duration of the signal. At very low frequencies a distinct phase shift was detected in the sine waves. This appeared as a phase lead, breaking the continuity of the output sine wave.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco
A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.
Rotating electric machine with fluid supported parts
Smith, Jr., Joseph L.; Kirtley, Jr., James L.
1981-01-01
A rotating electric machine in which the armature winding thereof and other parts are supported by a liquid to withstand the mechanical stresses applied during transient overloads and the like. In particular, a narrow gap is provided between the armature winding and the stator which supports it and this gap is filled with an externally pressurized viscous liquid. The liquid is externally pressurized sufficiently to balance the static loads on the armature winding. Transient mechanical loads which deform the armature winding alter the gap dimensions and thereby additionally pressurize the viscous liquid to oppose the armature winding deformation and more nearly uniformly to distribute the resulting mechanical stresses.
Dankelman, J; Stassen, H G; Spaan, J A
1990-03-01
In this study the response of driving pressure/flow ration on an abrupt change in heart rate was analysed. The difference between the response obtained with constant pressure and constant flow perfusion was also studied. The responses show a fast initial reversed phase followed by a slow phase caused by regulation. To test whether the initial phase could be the result of mechanical changes in the coronary circulation, a model for regulation was extended by the addition of four different mechanical models originating from the literature. These extended models were able to explain the fast initial phase. However, the mechanical model consisting of an intramyocardial compliance (C = 0.08 ml mm Hg-1 100 g-1) with a variable venous resistance, and the model consisting of a waterfall and a small compliance (C = 0.007 ml mm Hg-1 100g-1) both explained these responses best. The analysis showed that there is no direct relationship between rate of change of vascular tone and rate of change of pressure/flow ratio. However, on the basis of the two extended models, it can be predicted that the half-time for the response of regulation to be complete is about 9s with constant pressure perfusion and 15 s with constant flow perfusion.
Voicing produced by a constant velocity lung source
Howe, M. S.; McGowan, R. S.
2013-01-01
An investigation is made of the influence of subglottal boundary conditions on the prediction of voiced sounds. It is generally assumed in mathematical models of voicing that vibrations of the vocal folds are maintained by a constant subglottal mean pressure pI, whereas voicing is actually initiated by contraction of the chest cavity until the subglottal pressure becomes large enough to separate the vocal folds. The problem is reformulated to determine voicing characteristics in terms of a prescribed volumetric flow rate Qo of air from the lungs—the evolution of the resulting time-dependent subglottal mean pressure p¯_(t) is then governed by glottal mechanics, the aeroacoustics of the vocal tract, and the influence of continued contraction of the lungs. The new problem is analyzed in detail for an idealized mechanical vocal system that permits precise specification of all boundary conditions. Predictions of the glottal volume velocity pulse shape are found to be in good general agreement with the traditional constant-pI theory when pI is set equal to the time averaged value of p¯_(t). But, in all cases examined the constant-pI approximation yields values of the mean flow rates Qo and sound pressure levels that are smaller by as much as 10%. PMID:23556600
Jana, Rajesh; Saha, Pinku; Pareek, Vivek; Basu, Abhisek; Kapri, Sutanu; Bhattacharyya, Sayan; Mukherjee, Goutam Dev
2016-01-01
We have carried out detailed experimental investigations on polycrystalline CuO using dielectric constant, dc resistance, Raman spectroscopy and X-ray diffraction measurements at high pressures. Observation of anomalous changes both in dielectric constant and dielectric loss in the pressure range 3.7–4.4 GPa and reversal of piezoelectric current with reversal of poling field direction indicate to a change in ferroelectric order in CuO at high pressures. A sudden jump in Raman integrated intensity of Ag mode at 3.4 GPa and observation of Curie-Weiss type behaviour in dielectric constant below 3.7 GPa lends credibility to above ferroelectric transition. A slope change in the linear behaviour of the Ag mode and a minimum in the FWHM of the same indicate indirectly to a change in magnetic ordering. Since all the previous studies show a strong spin-lattice interaction in CuO, observed change in ferroic behaviour at high pressures can be related to a reentrant multiferroic ordering in the range 3.4 to 4.4 GPa, much earlier than predicted by theoretical studies. We argue that enhancement of spin frustration due to anisotropic compression that leads to change in internal lattice strain brings the multiferroic ordering to room temperature at high pressures. PMID:27530329
Burattini, R; Sipkema, P; van Huis, G A; Westerhof, N
1985-01-01
This study was performed to elucidate the effects of cardiac contraction on coronary pressure-flow relations. On the basis of the waterfall mechanism, a lumped model of the coronary arterial system is presented consisting of a proximal (epicardial) compliance, a coronary resistance, and an intramyocardial compliance. A "back"-pressure, assumed to be proportional (constant k) to left ventricular pressure, impedes flow. From steady-state measurements of circumflex coronary artery flow and inflow pressure, together with left ventricular pressure, the values of the three model parameters and the constant k have been estimated. In the control condition proximal compliance is found to be 1.7 X 10(-12) m4s2kg-1, intramyocardial compliance 110 X 10(-12)m4s2kg-1, and resistance 7.5 X 10(9) kgm-4s-1. The proportionality constant k is close to unity. Effects of changes in left ventricular pressure and inflow pressure and the effect of vasoactive drugs on the parameters are also investigated. Changes in coronary resistance are always opposite to changes in intramyocardial compliance. Sensitivity analysis showed that epicardial compliance plays its major role during isovolumic contraction and relaxation; resistance plays a role throughout the cardiac cycle but is more important in diastole than in systole, whereas intramyocardial compliance plays a role in systole and in early diastole.
Prenatal Care: Third Trimester Visits
... care provider will apply pressure to your abdomen (external cephalic version). If your baby remains in a breech position, ... College of Obstetricians and Gynecologists; 2010. Hofmeyr GJ. External cephalic version. http://www.uptodate.com/home. Accessed July 10, ...
Contrast detection in fluid-saturated media with magnetic resonance poroelastography
Perriñez, Phillip R.; Pattison, Adam J.; Kennedy, Francis E.; Weaver, John B.; Paulsen, Keith D.
2010-01-01
Purpose: Recent interest in the poroelastic behavior of tissues has led to the development of magnetic resonance poroelastography (MRPE) as an alternative to single-phase MR elastographic image reconstruction. In addition to the elastic parameters (i.e., Lamé’s constants) commonly associated with magnetic resonance elastography (MRE), MRPE enables estimation of the time-harmonic pore-pressure field induced by external mechanical vibration. Methods: This study presents numerical simulations that demonstrate the sensitivity of the computed displacement and pore-pressure fields to a priori estimates of the experimentally derived model parameters. In addition, experimental data collected in three poroelastic phantoms are used to assess the quantitative accuracy of MR poroelastographic imaging through comparisons with both quasistatic and dynamic mechanical tests. Results: The results indicate hydraulic conductivity to be the dominant parameter influencing the deformation behavior of poroelastic media under conditions applied during MRE. MRPE estimation of the matrix shear modulus was bracketed by the values determined from independent quasistatic and dynamic mechanical measurements as expected, whereas the contrast ratios for embedded inclusions were quantitatively similar (10%–15% difference between the reconstructed images and the mechanical tests). Conclusions: The findings suggest that the addition of hydraulic conductivity and a viscoelastic solid component as parameters in the reconstruction may be warranted. PMID:20831058
NASA Technical Reports Server (NTRS)
Buckley, Theresa M.
1988-01-01
Following the Challenger tragedy, an evaluation of the integrated main propulsion system flight data revealed a premature decay in the hydrogen external tank ullage pressure. A reconstruction of predicted ullage pressure versus time indicated an inconsistency between predicted and measured ullage pressure starting at approximately 65.5 seconds into the flight and reaching a maximum value between 72 and 72.9 seconds. This discrepancy could have been caused by a hydrogen gas leak or by a liquied hydrogen leak that occurred either in the pressurization system or in the external tank. The corresponding leak rates over the time interval from 65.5 to 72.9 seconds were estimated to range from 0.28 kg/s (0.62 lbm/s) + or - 41 percent to between 0.43 and 0.51kg/s (0.94 and 1.12lbs/s) + or - 1 percent for a gas leak and from 72.9 kg/s (160.5 lbs/s) + or - 41 percent to between 111.6 and 133.2 kg/s (245.8 and 293.3 lbs/s) + or - 1 percent for a liquid leak. No speculation is made to ascertain whether the leak is liquid or gas, as this cannot be determined from the analysis performed. Four structural failures in the hydrogen external tank were considered to explain the leak rates. A break in the 5-cm (2 in) pressurization line, in the 13-cm (5 in) vent line, or in the 43-cm (17 in) feedline is not likely. A break in the 10-cm (4 in) recirculation line with a larger structural failure occurring in the 72 to 73-second time period, the time of the visibly identified premature pressure decay, does seem plausible and the most likely of the four modes considered. These modes are not all-inclusive and do not preclude the possibility of a leak elsewhere in the tank.
Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin
2012-07-01
Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Design concept for pressure switch calibrator
NASA Technical Reports Server (NTRS)
Slingerland, M. G.
1966-01-01
Calibrator and switch design enables pressure switches to operate under 150 g shock loads. The design employs a saturated liquid-to-vapor phase transition at constant pressure to produce a known force independent of displacement over a usable range.
ERIC Educational Resources Information Center
Luyben, William L.; Tuzla, Kemal
2010-01-01
Most chemical engineering undergraduate laboratories have fluid mechanics experiments in which pressure drops through pipes are measured over a range of Reynolds numbers. The standard fluid is liquid water, which is essentially incompressible. Since density is constant, pressure drop does not depend on the pressure in the pipe. In addition, flow…
Probing the effect of tip pressure on fungal growth: Application to Aspergillus nidulans
NASA Astrophysics Data System (ADS)
González-Bermúdez, Blanca; Li, Qingxuan; Guinea, Gustavo V.; Peñalva, Miguel A.; Plaza, Gustavo R.
2017-08-01
The study of fungal cells is of great interest due to their importance as pathogens and as fermenting fungi and for their appropriateness as model organisms. The differential pressure between the hyphal cytoplasm and the bordering medium is essential for the growth process, because the pressure is correlated with the growth rate. Notably, during the invasion of tissues, the external pressure at the tip of the hypha may be different from the pressure in the surrounding medium. We report the use of a method, based on the micropipette-aspiration technique, to study the influence of this external pressure at the hyphal tip. Moreover, this technique makes it possible to study hyphal growth mechanics in the case of very thin hyphae, not accessible to turgor pressure probes. We found a correlation between the local pressure at the tip and the growth rate for the species Arpergillus nidulans. Importantly, the proposed method allows one to measure the pressure at the tip required to arrest the hyphal growth. Determining that pressure could be useful to develop new medical treatments for fungal infections. Finally, we provide a mechanical model for these experiments, taking into account the cytoplasm flow and the wall deformation.
Choi, Sungjoon; Lee, Haksue; Moon, Wonkyu
2010-09-01
Although an air-backed thin plate is an effective sound receiver structure, it is easily damaged via pressure unbalance caused by external hydrostatic pressure. To overcome this difficulty, a simple pressure-balancing module is proposed. Despite its small size and relative simplicity, with proper design and operation, micro-channel structure provides a solution to the pressure-balancing problem. If the channel size is sufficiently small, the gas-liquid interface may move back and forth without breach by the hydrostatic pressure since the surface tension can retain the interface surface continuously. One input port of the device is opened to an intermediate liquid, while the other port is connected to the air-backing chamber. As the hydrostatic pressure increases, the liquid in the micro-channel compresses the air, and the pressure in the backing chamber is then equalized to match the external hydrostatic pressure. To validate the performance of the proposed mechanism, a micro-channel prototype is designed and integrated with the piezoelectric micro-machined flexural sensor developed in our previous work. The working principle of the mechanism is experimentally verified. In addition, the effect of hydrostatic pressure on receiving sensitivity is evaluated and compared with predicted behavior.
NASA Astrophysics Data System (ADS)
Kacimov, A. R.; Obnosov, Yu. V.
2017-03-01
The Russian engineer Kornev in his 1935 book raised perspectives of subsurface "negative pressure" irrigation, which have been overlooked in modern soil science. Kornev's autoirrigation utilizes wicking of a vacuumed water from a porous pipe into a dry adjacent soil. We link Kornev's technology with a slightly modified Philip (1984)'s analytical solutions for unsaturated flow from a 2-D cylindrical pipe in an infinite domain. Two Darcian flows are considered and connected through continuity of pressure along the pipe-soil contact. The first fragment is a thin porous pipe wall in which water seeps at tension saturation; the hydraulic head is a harmonic function varying purely radially across the wall. The Thiem solution in this fragment gives the boundary condition for azimuthally varying suction pressure in the second fragment, ambient soil, making the exterior of the pipe. The constant head, rather than Philip's isobaricity boundary condition, along the external wall slightly modifies Philip's formulae for the Kirchhoff potential and pressure head in the soil fragment. Flow characteristics (magnitudes of the Darcian velocity, total flow rate, and flow net) are explicitly expressed through series of Macdonald's functions. For a given pipe's external diameter, wall thickness, position of the pipe above a free water datum in the supply tank, saturated conductivities of the wall and soil, and soil's sorptive number, a nonlinear equation with respect to the total discharge from the pipe is obtained and solved by a computer algebra routine. Efficiency of irrigation is evaluated by computation of the moisture content within selected zones surrounding the porous pipe.
High-pressure endurable flexible tactile actuator based on microstructured dielectric elastomer
NASA Astrophysics Data System (ADS)
Pyo, Dongbum; Ryu, Semin; Kyung, Ki-Uk; Yun, Sungryul; Kwon, Dong-Soo
2018-02-01
We demonstrate a robust flexible tactile actuator that is capable of working under high external pressures. The tactile actuator is based on a pyramidal microstructured dielectric elastomer layer inducing variation in both mechanical and dielectric properties. The vibrational performance of the actuator can be modulated by changing the geometric parameter of the microstructures. We evaluated the performance of the actuator under high-pressure loads up to 25 kPa, which is over the typical range of pressure applied when humans touch or manipulate objects. Due to the benefit of nonlinearity of the pyramidal structure, the actuator could maintain high mechanical output under various external pressures in the frequency range of 100-200 Hz, which is the most sensitive to vibration acceleration for human finger pads. The responses are not only fast, reversible, and highly durable under consecutive cyclic operations, but also large enough to impart perceivable vibrations for haptic feedback on practical wearable device applications.
Strain measurement in the wavy-ply region of an externally pressurized cross-ply composite ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gascoigne, H.E.; Abdallah, M.G.
1996-07-01
Ply-level strains are determined in the cross-section of an externally pressurized cross-ply (3:1 circumferential to axial fiber ratio) graphite-epoxy ring containing an isolated circumferential wavy region. A special test fixture was used which permitted measuring orthogonal displacement components in the wavy area using moire interferometry as the pressure was increased. Strain components were determined at selected locations in the wavy area up to approximately90% of failure pressure. The study shows: (1) large interlaminar shear strains, which are non-existent in the perfect ring, are present near the wave inflection points; (2) the wavy plies generate increased interlaminar normal compressive strains inmore » both circumferential and axial plies along a radial line coinciding with maximum wave amplitude; and (3) nonlinear strain response begins at approximately 60% of failure pressure.« less
The zonal-mean and regional tropospheric pressure responses to changes in ionospheric potential
NASA Astrophysics Data System (ADS)
Zhou, Limin; Tinsley, Brian; Wang, Lin; Burns, Gary
2018-06-01
Global reanalysis data reveal daily surface pressure responses to changes in the global ionospheric potential in both polar and sub-polar regions. We use 21 years of data to show that the pressure response to externally-induced ionospheric potential changes, that are due to the interplanetary magnetic field east-west (IMF By) component, are present in two separate decadal intervals, and follow the opposite ionospheric potential changes in the Arctic and Antarctic for a given By. We use the 4 years of available data to show that the pressure responses to changes in internally generated ionospheric potential, that are caused by low-latitude thunderstorms and highly electrified clouds, agree in sign and sensitivity with those externally generated. We have determined that the daily varying pressure responses are stronger in local winter and spring. The pressure responses at polar latitudes are predominantly over the Antarctic and Greenland ice caps, and those at sub-polar latitudes are of opposite sign, mainly over oceans. A lead-lag analysis confirms that the responses maximize within two days of the ionospheric potential input. Regions of surface pressure fluctuating by about 4 hPa in winter are found with ionospheric potential changes of about 40 kV. The consistent pressure response to the independent external and internal inputs strongly supports the reality of a cloud microphysical mechanism affected by the global electric circuit. A speculative mechanism involves the ionosphere-earth current density Jz, which produces space charge at cloud boundaries and electrically charged droplets and aerosol particles. Ultrafine aerosol particles, under the action of electro-anti-scavenging, are enabled to grow to condensation nuclei size, affecting cloud microphysics and cloud opacity and surface pressure on time scales of hours.
Condition for a Bounded System of Klein-Gordon Particles in Electric and Magnetic Fields
NASA Astrophysics Data System (ADS)
Kisoglu, Hasan Fatih; Sogut, Kenan
2018-07-01
We investigate the motion of relativistic spinless particles in an external electromagnetic field that is considered to has a constant magnetic field and a time-dependent electric field. For such a system, we obtain analytical eigenfunctions through Asymptotic Iteration Method. We also obtain a condition of choosing the external magnetic field for which the system is bounded with usage of the method in perturbation theory.
NASA Astrophysics Data System (ADS)
Gao, D.; Morley, N. B.
2002-12-01
A 2D model for MHD free surface flow in a spanwise field is developed. The model, designed to simulate film flows of liquid metals in future thermonuclear fusion reactors, considers an applied spanwise magnetic field with spatial and temporal variation and an applied streamwise external current. A special case - a thin falling film flow in spanwise magnetic field with constant gradient and constant applied external streamwise current, is here investigated in depth to gain insight into the behavior of the MHD film flow. The fully developed flow solution is derived and initial linear stability analysis is performed for this special case. It is seen that the velocity profile is significantly changed due to the presence of the MHD effect, resulting in the free surface analog of the classic M-shape velocity profile seen in developing pipe flows in a field gradient. The field gradient is also seen to destabilize the film flow under most conditions. The effect of external current depends on the relative direction of the field gradient to the current direction. By controlling the magnitude of an external current, it is possible to obtain a linearly stable falling film under these magnetic field conditions. Tables 1, Figs 12, Refs 20.
Apparatus for in-situ calibration of instruments that measure fluid depth
Campbell, Melvin D.
1994-01-01
The present invention provides a method and apparatus for in-situ calibration of distance measuring equipment. The method comprises obtaining a first distance measurement in a first location, then obtaining at least one other distance measurement in at least one other location of a precisely known distance from the first location, and calculating a calibration constant. The method is applied specifically to calculating a calibration constant for obtaining fluid level and embodied in an apparatus using a pressure transducer and a spacer of precisely known length. The calibration constant is used to calculate the depth of a fluid from subsequent single pressure measurements at any submerged position.
NASA Astrophysics Data System (ADS)
Rashid, A. A.; Sidek, A. A.; Suffian, S. A.; Daud, M. R. C.
2018-01-01
The idea of assimilating green supply chain is to integrate and establish environmental management into the supply chain practices. The study aims to explore how environmental management competitive pressure influences a SME company in Malaysia to incorporate green supply chain integration, which is an efficient platform to develop environmental innovation. This study further advances green supply chain management research in Malaysia by using the method of quantitative analysis to analyze the model developed which data will be collected based on a sample of SMEs in Malaysia in manufacturing sector. The model developed in this study illustrates how environmental management competitive pressure from main competitors affects three fundamental dimensions of green supply chain integration. The research findings suggest that environmental management competitive pressure is a vital driving force for a SME company to incorporate internal and external collaboration in developing green product innovation. From the analysis conducted, the study strongly demonstrated that the best way for a company to counteract competitor’s environmental management success is to first implement strong internal green product development process then move to incorporate external environmental management innovation between their suppliers and customers. The findings also show that internal integration of green product innovation fully mediates the relationship of environmental management competitive pressure and the external integration of green product innovation.
Correction of aortic insufficiency with an external adjustable prosthetic aortic ring.
Gogbashian, Andrew; Ghanta, Ravi K; Umakanthan, Ramanan; Rangaraj, Aravind T; Laurence, Rita G; Fox, John A; Cohn, Lawrence H; Chen, Frederick Y
2007-09-01
Less invasive, valve-sparing options are needed for patients with aortic insufficiency (AI). We sought to evaluate the feasibility of reducing AI with an external adjustable aortic ring in an ovine model. To create AI, five sheep underwent patch plasty enlargement of the aortic annulus and root by placement of a 10 x 15 mm pericardial patch between the right and noncoronary cusps. An adjustable external ring composed of a nylon band was fabricated and placed around the aortic root. Aortic flow, aortic pressure, and left ventricular pressures were measured with the ring loose (off) and tightened (on). Mean regurgitant orifice area decreased by 86%, from 0.07 +/- 0.03 cm2 (ring loose, off) to 0.01 +/- 0.00 cm2 (ring tightened, on) [p < 0.01]. The regurgitant fraction decreased from 18 +/- 4% to 2 +/- 1% [p < 0.01]. The ring did not significantly affect stroke volume and aortic pressure. An ovine model of aortic root dilatation resulting in acute AI has been developed. In this model, application of an external, adjustable constricting aortic ring eliminated AI. An aortic ring may be a useful adjunct in reducing AI secondary to annular dilatation.
Sound Transmission through Two Concentric Cylindrical Sandwich Shells
NASA Technical Reports Server (NTRS)
Tang, Yvette Y.; Silcox, Richard J.; Robinson, Jay H.
1996-01-01
This paper solves the problem of sound transmission through a system of two infinite concentric cylindrical sandwich shells. The shells are surrounded by external and internal fluid media and there is fluid (air) in the annular space between them. An oblique plane sound wave is incident upon the surface of the outer shell. A uniform flow is moving with a constant velocity in the external fluid medium. Classical thin shell theory is applied to the inner shell and first-order shear deformation theory is applied to the outer shell. A closed form for transmission loss is derived based on modal analysis. Investigations have been made for the impedance of both shells and the transmission loss through the shells from the exterior into the interior. Results are compared for double sandwich shells and single sandwich shells. This study shows that: (1) the impedance of the inner shell is much smaller than that of the outer shell so that the transmission loss is almost the same in both the annular space and the interior cavity of the shells; (2) the two concentric sandwich shells can produce an appreciable increase of transmission loss over single sandwich shells especially in the high frequency range; and (3) design guidelines may be derived with respect to the noise reduction requirement and the pressure in the annular space at a mid-frequency range.
NASA Technical Reports Server (NTRS)
Dash, S. M.; Pergament, H. S.
1978-01-01
The development of a computational model (BOAT) for calculating nearfield jet entrainment, and its incorporation in an existing methodology for the prediction of nozzle boattail pressures, is discussed. The model accounts for the detailed turbulence and thermochemical processes occurring in the mixing layer formed between a jet exhaust and surrounding external stream while interfacing with the inviscid exhaust and external flowfield regions in an overlaid, interactive manner. The ability of the BOAT model to analyze simple free shear flows is assessed by comparisons with fundamental laboratory data. The overlaid procedure for incorporating variable pressures into BOAT and the entrainment correction employed to yield an effective plume boundary for the inviscid external flow are demonstrated. This is accomplished via application of BOAT in conjunction with the codes comprising the NASA/LRC patched viscous/inviscid methodology for determining nozzle boattail drag for subsonic/transonic external flows.
Pressure-induced enhancement in the thermoelectric properties of monolayer and bilayer SnSe2
NASA Astrophysics Data System (ADS)
Zou, Daifeng; Yu, Chuanbin; Li, Yuhao; Ou, Yun; Gao, Yongyi
2018-03-01
The electronic structures of monolayer and bilayer SnSe2 under pressure were investigated by using first-principles calculations including van der Waals interactions. For monolayer SnSe2, the variation of electronic structure under pressure is controlled by pressure-dependent lattice parameters. For bilayer SnSe2, the changes in electronic structure under pressure are dominated by intralayer and interlayer atomic interactions. The n-type thermoelectric properties of monolayer and bilayer SnSe2 under pressure were calculated on the basis of the semi-classical Boltzmann transport theory. It was found that the electrical conductivity of monolayer and bilayer SnSe2 can be enhanced under pressure, and such dependence can be attributed to the pressure-induced changes of the Se-Sn antibonding states in conduction band. Finally, the doping dependence of power factors of n-type monolayer and bilayer SnSe2 at three different pressures were estimated, and the results unveiled that thermoelectric performance of n-type monolayer and bilayer SnSe2 can be improved by applying external pressure. This study benefits to understand the nature of the transport properties for monolayer and bilayer SnSe2 under pressure, and it offers valuable insight for designing high-performance thermoelectric few-layered SnSe2 through strain engineering induced by external pressure.
Pressure-induced enhancement in the thermoelectric properties of monolayer and bilayer SnSe2.
Zou, Daifeng; Yu, Chuanbin; Li, Yuhao; Ou, Yun; Gao, Yongyi
2018-03-01
The electronic structures of monolayer and bilayer SnSe 2 under pressure were investigated by using first-principles calculations including van der Waals interactions. For monolayer SnSe 2 , the variation of electronic structure under pressure is controlled by pressure-dependent lattice parameters. For bilayer SnSe 2 , the changes in electronic structure under pressure are dominated by intralayer and interlayer atomic interactions. The n -type thermoelectric properties of monolayer and bilayer SnSe 2 under pressure were calculated on the basis of the semi-classical Boltzmann transport theory. It was found that the electrical conductivity of monolayer and bilayer SnSe 2 can be enhanced under pressure, and such dependence can be attributed to the pressure-induced changes of the Se-Sn antibonding states in conduction band. Finally, the doping dependence of power factors of n -type monolayer and bilayer SnSe 2 at three different pressures were estimated, and the results unveiled that thermoelectric performance of n -type monolayer and bilayer SnSe 2 can be improved by applying external pressure. This study benefits to understand the nature of the transport properties for monolayer and bilayer SnSe 2 under pressure, and it offers valuable insight for designing high-performance thermoelectric few-layered SnSe 2 through strain engineering induced by external pressure.
Shallow Underground Tunnel/Chamber Explosion Test Program Summary Report
1990-08-01
TECHNICAL REPORT SL-90-10 SHALLOW UNDERGROUND TUNNEL /CHAMBERo ni neers= EXPLOSION TEST PROGRAM SUMMARY REPORT ~ by .11 ~ ~A.Charles E. Joachim N...hazardous et f ects produced by thle eXPlO.SiOll. Fhe prugrari was divided into four study areas; tunnel /c’hamber pressure, external ai rhlast...extern:il grounid motion, andl ejecta/debris. The tunnel /chamber pressure meaisurements 11roe i dell (LI La onl thle i nte rnalI explosion environment and the
Stapes displacement and intracochlear pressure in response to very high level, low frequency sounds.
Greene, Nathaniel T; Jenkins, Herman A; Tollin, Daniel J; Easter, James R
2017-05-01
The stapes is held in the oval window by the stapedial annular ligament (SAL), which restricts total peak-to-peak displacement of the stapes. Previous studies have suggested that for moderate (<130 dB SPL) sound levels intracochlear pressure (P IC ), measured at the base of the cochlea far from the basilar membrane, increases directly proportionally with stapes displacement (D Stap ), thus a current model of impulse noise exposure (the Auditory Hazard Assessment Algorithm for Humans, or AHAAH) predicts that peak P IC will vary linearly with D Stap up to some saturation point. However, no direct tests of D Stap , or of the relationship with P IC during such motion, have been performed during acoustic stimulation of the human ear. In order to examine the relationship between D Stap and P IC to very high level sounds, measurements of D Stap and P IC were made in cadaveric human temporal bones. Specimens were prepared by mastoidectomy and extended facial recess to expose the ossicular chain. Measurements of P IC were made in scala vestibuli (P SV ) and scala tympani (P ST ), along with the SPL in the external auditory canal (P EAC ), concurrently with laser Doppler vibrometry (LDV) measurements of stapes velocity (V Stap ). Stimuli were moderate (∼100 dB SPL) to very high level (up to ∼170 dB SPL), low frequency tones (20-2560 Hz). Both D Stap and P SV increased proportionally with sound pressure level in the ear canal up to approximately ∼150 dB SPL, above which both D Stap and P SV showed a distinct deviation from proportionality with P EAC . Both D Stap and P SV approached saturation: D Stap at a value exceeding 150 μm, which is substantially higher than has been reported for small mammals, while P SV showed substantial frequency dependence in the saturation point. The relationship between P SV and D Stap remained constant, and cochlear input impedance did not vary across the levels tested, consistent with prior measurements at lower sound levels. These results suggest that P SV sound pressure holds constant relationship with D Stap , described by the cochlear input impedance, at these, but perhaps not higher, stimulation levels. Additionally, these results indicate that the AHAAH model, which was developed using results from small animals, underestimates the sound pressure levels in the cochlea in response to high level sound stimulation, and must be revised. Copyright © 2017 Elsevier B.V. All rights reserved.
Collapse of Corroded Pipelines under Combined Tension and External Pressure
Ye, Hao; Yan, Sunting; Jin, Zhijiang
2016-01-01
In this work, collapse of corroded pipeline under combined external pressure and tension is investigated through numerical method. Axially uniform corrosion with symmetric imperfections is firstly considered. After verifying with existing experimental results, the finite element model is used to study the effect of tension on collapse pressure. An extensive parametric study is carried out using Python script and FORTRAN subroutine to investigate the influence of geometric parameters on the collapse behavior under combined loads. The results are used to develop an empirical equation for estimating the collapse pressure under tension. In addition, the effects of loading path, initial imperfection length, yielding anisotropy and corrosion defect length on the collapse behavior are also investigated. It is found that tension has a significant influence on collapse pressure of corroded pipelines. Loading path and anisotropic yielding are also important factors affecting the collapse behavior. For pipelines with relatively long corrosion defect, axially uniform corrosion models could be used to estimate the collapse pressure. PMID:27111544
NASA Astrophysics Data System (ADS)
Morandi, V.; Galli, M.; Marabelli, F.; Comoretto, D.
2010-04-01
In this work, we combined an experimental technique and a detailed data analysis to investigate the influence of an applied pressure on the anisotropic dielectric functions of highly oriented poly(p-phenylene vinylene) (PPV). The dielectric constants were derived from polarized reflectance spectra recorded through a diamond anvil cell up to 50 kbar. The presence of the diamond anvils strongly affects measured spectra requiring the development in an optical model able to take all spurious effects into account. A parametric procedure was then applied to derive the complex dielectric constants for both polarizations as a function of pressure. A detailed analysis of their pressure dependence allows addressing the role of intermolecular interactions and electron-phonon coupling in highly oriented PPV.
Pressure-induced increase of exciton-LO-phonon coupling in a ZnCdSe/ZnSe quantum well
NASA Astrophysics Data System (ADS)
Guo, Z. Z.; Liang, X. X.; Ban, S. L.
2003-07-01
The possibility of pressure-induced increase of exciton-LO-phonon coupling in ZnCdSe/ZnSe quantum wells is studied. The ground state binding energies of the heavy hole excitons are calculated using a variational method with consideration of the electron-phonon interaction and the pressure dependence of the parameters. The results show that for quantum wells with intermediate well width, the exciton binding energy and the LO-phonon energy may coincide in the course of pressure increasing, resulting in the increase of exciton-LO-phonon coupling. It is also found that among the pressure-dependent parameters, the influence of the lattice constant is the most important one. The changes of both the effective masses and the dielectric constants have obvious effects on the exciton binding energy, but their influences are counterbalanced.
Adjoint-based constant-mass partial derivatives
Favorite, Jeffrey A.
2017-09-01
In transport theory, adjoint-based partial derivatives with respect to mass density are constant-volume derivatives. Likewise, adjoint-based partial derivatives with respect to surface locations (i.e., internal interface locations and the outer system boundary) are constant-density derivatives. This study derives the constant-mass partial derivative of a response with respect to an internal interface location or the outer system boundary and the constant-mass partial derivative of a response with respect to the mass density of a region. Numerical results are given for a multiregion two-dimensional (r-z) cylinder for three very different responses: the uncollided gamma-ray flux at an external detector point, k effmore » of the system, and the total neutron leakage. Finally, results from the derived formulas compare extremely well with direct perturbation calculations.« less
NASA Astrophysics Data System (ADS)
Khordad, R.
2010-03-01
The influence of temperature and pressure, simultaneously, on the binding energy of a hydrogenic donor impurity in a ridge GaAs/Ga 1- xAl xAs quantum wire is studied using a variational procedure within the effective mass approximation. The subband energy and the binding energy of the donor impurity in its ground state as a function of the wire bend width and impurity location at different temperatures and pressures are calculated. The results show that, when the temperature increases, the donor binding energy decreases for a constant applied pressure for all wire bend widths. Also, the binding energy increases by increasing the pressure for a constant temperature for all wire bend widths. In addition, when the temperature and pressure are applied simultaneously the binding energy decreases as the quantum wire bend width increases. On the whole, it is deduced that the temperature and pressure have important effects on the donor binding energy in a V-groove quantum wire.
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
Development of a Linear Stirling Model with Varying Heat Inputs
NASA Technical Reports Server (NTRS)
Regan, Timothy F.; Lewandowski, Edward J.
2007-01-01
The linear model of the Stirling system developed by NASA Glenn Research Center (GRC) has been extended to include a user-specified heat input. Previously developed linear models were limited to the Stirling convertor and electrical load. They represented the thermodynamic cycle with pressure factors that remained constant. The numerical values of the pressure factors were generated by linearizing GRC s non-linear System Dynamic Model (SDM) of the convertor at a chosen operating point. The pressure factors were fixed for that operating point, thus, the model lost accuracy if a transition to a different operating point were simulated. Although the previous linear model was used in developing controllers that manipulated current, voltage, and piston position, it could not be used in the development of control algorithms that regulated hot-end temperature. This basic model was extended to include the thermal dynamics associated with a hot-end temperature that varies over time in response to external changes as well as to changes in the Stirling cycle. The linear model described herein includes not only dynamics of the piston, displacer, gas, and electrical circuit, but also the transient effects of the heater head thermal inertia. The linear version algebraically couples two separate linear dynamic models, one model of the Stirling convertor and one model of the thermal system, through the pressure factors. The thermal system model includes heat flow of heat transfer fluid, insulation loss, and temperature drops from the heat source to the Stirling convertor expansion space. The linear model was compared to a nonlinear model, and performance was very similar. The resulting linear model can be implemented in a variety of computing environments, and is suitable for analysis with classical and state space controls analysis techniques.
Development of a Linear Stirling System Model with Varying Heat Inputs
NASA Technical Reports Server (NTRS)
Regan, Timothy F.; Lewandowski, Edward J.
2007-01-01
The linear model of the Stirling system developed by NASA Glenn Research Center (GRC) has been extended to include a user-specified heat input. Previously developed linear models were limited to the Stirling convertor and electrical load. They represented the thermodynamic cycle with pressure factors that remained constant. The numerical values of the pressure factors were generated by linearizing GRC's nonlinear System Dynamic Model (SDM) of the convertor at a chosen operating point. The pressure factors were fixed for that operating point, thus, the model lost accuracy if a transition to a different operating point were simulated. Although the previous linear model was used in developing controllers that manipulated current, voltage, and piston position, it could not be used in the development of control algorithms that regulated hot-end temperature. This basic model was extended to include the thermal dynamics associated with a hot-end temperature that varies over time in response to external changes as well as to changes in the Stirling cycle. The linear model described herein includes not only dynamics of the piston, displacer, gas, and electrical circuit, but also the transient effects of the heater head thermal inertia. The linear version algebraically couples two separate linear dynamic models, one model of the Stirling convertor and one model of the thermal system, through the pressure factors. The thermal system model includes heat flow of heat transfer fluid, insulation loss, and temperature drops from the heat source to the Stirling convertor expansion space. The linear model was compared to a nonlinear model, and performance was very similar. The resulting linear model can be implemented in a variety of computing environments, and is suitable for analysis with classical and state space controls analysis techniques.
Fast Reverse Propagation of Sound in the Living Cochlea
He, Wenxuan; Fridberger, Anders; Porsov, Edward; Ren, Tianying
2010-01-01
Abstract The auditory sensory organ, the cochlea, not only detects but also generates sounds. Such sounds, otoacoustic emissions, are widely used for diagnosis of hearing disorders and to estimate cochlear nonlinearity. However, the fundamental question of how the otoacoustic emission exits the cochlea remains unanswered. In this study, emissions were provoked by two tones with a constant frequency ratio, and measured as vibrations at the basilar membrane and at the stapes, and as sound pressure in the ear canal. The propagation direction and delay of the emission were determined by measuring the phase difference between basilar membrane and stapes vibrations. These measurements show that cochlea-generated sound arrives at the stapes earlier than at the measured basilar membrane location. Data also show that basilar membrane vibration at the emission frequency is similar to that evoked by external tones. These results conflict with the backward-traveling-wave theory and suggest that at low and intermediate sound levels, the emission exits the cochlea predominantly through the cochlear fluids. PMID:20513393
NASA Astrophysics Data System (ADS)
Barbulescu, M.; Erdélyi, R.
2018-06-01
Recent observations have shown that bulk flow motions in structured solar plasmas, most evidently in coronal mass ejections (CMEs), may lead to the formation of Kelvin-Helmholtz instabilities (KHIs). Analytical models are thus essential in understanding both how the flows affect the propagation of magnetohydrodynamic (MHD) waves, and what the critical flow speed is for the formation of the KHI. We investigate both these aspects in a novel way: in a steady magnetic slab embedded in an asymmetric environment. The exterior of the slab is defined as having different equilibrium values of the background density, pressure, and temperature on either side. A steady flow and constant magnetic field are present in the slab interior. Approximate solutions to the dispersion relation are obtained analytically and classified with respect to mode and speed. General solutions and the KHI thresholds are obtained numerically. It is shown that, generally, both the KHI critical value and the cut-off speeds for magnetoacoustic waves are lowered by the external asymmetry.
Blood pressure and the contractility of a human leg muscle.
Luu, Billy L; Fitzpatrick, Richard C
2013-11-01
These studies investigate the relationships between perfusion pressure, force output and pressor responses for the contracting human tibialis anterior muscle. Eight healthy adults were studied. Changing the height of tibialis anterior relative to the heart was used to control local perfusion pressure. Electrically stimulated tetanic force output was highly sensitive to physiological variations in perfusion pressure showing a proportionate change in force output of 6.5% per 10 mmHg. This perfusion-dependent change in contractility begins within seconds and is reversible with a 53 s time constant, demonstrating a steady-state equilibrium between contractility and perfusion pressure. These stimulated contractions did not produce significant cardiovascular responses, indicating that the muscle pressor response does not play a major role in cardiovascular regulation at these workloads. Voluntary contractions at forces that would require constant motor drive if perfusion pressure had remained constant generated a central pressor response when perfusion pressure was lowered. This is consistent with a larger cortical drive being required to compensate for the lost contractility with lower perfusion pressure. The relationship between contractility and perfusion for this large postural muscle was not different from that of a small hand muscle (adductor pollicis) and it responded similarly to passive peripheral and active central changes in arterial pressure, but extended over a wider operating range of pressures. If we consider that, in a goal-oriented motor task, muscle contractility determines central motor output and the central pressor response, these results indicate that muscle would fatigue twice as fast without a pressor response. From its extent, timing and reversibility we propose a testable hypothesis that this change in contractility arises through contraction- and perfusion-dependent changes in interstitial K(+) concentration.
Blood pressure and the contractility of a human leg muscle
Luu, Billy L; Fitzpatrick, Richard C
2013-01-01
These studies investigate the relationships between perfusion pressure, force output and pressor responses for the contracting human tibialis anterior muscle. Eight healthy adults were studied. Changing the height of tibialis anterior relative to the heart was used to control local perfusion pressure. Electrically stimulated tetanic force output was highly sensitive to physiological variations in perfusion pressure showing a proportionate change in force output of 6.5% per 10 mmHg. This perfusion-dependent change in contractility begins within seconds and is reversible with a 53 s time constant, demonstrating a steady-state equilibrium between contractility and perfusion pressure. These stimulated contractions did not produce significant cardiovascular responses, indicating that the muscle pressor response does not play a major role in cardiovascular regulation at these workloads. Voluntary contractions at forces that would require constant motor drive if perfusion pressure had remained constant generated a central pressor response when perfusion pressure was lowered. This is consistent with a larger cortical drive being required to compensate for the lost contractility with lower perfusion pressure. The relationship between contractility and perfusion for this large postural muscle was not different from that of a small hand muscle (adductor pollicis) and it responded similarly to passive peripheral and active central changes in arterial pressure, but extended over a wider operating range of pressures. If we consider that, in a goal-oriented motor task, muscle contractility determines central motor output and the central pressor response, these results indicate that muscle would fatigue twice as fast without a pressor response. From its extent, timing and reversibility we propose a testable hypothesis that this change in contractility arises through contraction- and perfusion-dependent changes in interstitial K+ concentration. PMID:24018946
Fahrenkrug, Jan; Georg, Birgitte; Hannibal, Jens; Jørgensen, Henrik Løvendahl
2018-04-01
The intraocular pressure of mice displays a daily rhythmicity being highest during the dark period. The present study was performed to elucidate the role of the circadian clock and light in the diurnal and the circadian variations in intraocular pressure in mice, by using animals with disrupted clock function (VPAC2 receptor knockout mice) or impaired light information to the clock (PACAP knockout mice). In wildtype mice, intraocular pressure measured under light/dark conditions showed a statistically significant 24 h sinusoidal rhythm with nadir during the light phase and peak during the dark phase. After transfer of the wildtype mice into constant darkness, the intraocular pressure increased, but the rhythmic changes in intraocular pressure continued with a pattern identical to that obtained during the light/dark cycle. The intraocular pressure in VPAC2 receptor deficient mice during light/dark conditions also showed a sinusoidal pattern with significant changes as a function of a 24 h cycle. However, transfer of the VPAC2 receptor knockout mice into constant darkness completely abolished the rhythmic changes in intraocular pressure. The intraocular pressure in PACAP deficient mice oscillated significantly during both 24 h light and darkness and during constant darkness. During LD conditions, the amplitude of PACAP deficient was significantly lower compared to wildtype mice, resulting in higher daytime and lower nighttime values. In conclusion, by studying the VPAC2 receptor knockout mouse which lacks circadian control and the PACAP knockout mouse which displays impaired light signaling, we provided evidence that the daily intraocular pressure rhythms are primarily generated by the circadian master clock and to a lesser extent by environmental light and darkness. Copyright © 2018 Elsevier Ltd. All rights reserved.
Constant-Differential-Pressure Two-Fluid Accumulator
NASA Technical Reports Server (NTRS)
Piecuch, Benjamin; Dalton, Luke T.
2010-01-01
A two-fluid accumulator has been designed, built, and demonstrated to provide an acceptably close approximation to constant differential static pressure between two fluids over the full ranges of (1) accumulator stroke, (2) rates of flow of the fluids, and (3) common static pressure applied to the fluids. Prior differential- pressure two-fluid accumulators are generally not capable of maintaining acceptably close approximations to constant differential pressures. The inadequacies of a typical prior differential-pressure two-fluid accumulator can be summarized as follows: The static differential pressure is governed by the intrinsic spring rate (essentially, the stiffness) of an accumulator tank. The spring rate can be tailored through selection of the tank-wall thickness, selection of the number and/or shape of accumulator convolutions, and/or selection of accumulator material(s). Reliance on the intrinsic spring rate of the tank results in three severe limitations: (1) The spring rate and the expulsion efficiency tend to be inversely proportional to each other: that is to say, as the stiffness (and thus the differential pressure) is increased, the range of motion of the accumulator is reduced. (2) As the applied common static pressure increases, the differential pressure tends to decrease. An additional disadvantage, which may or may not be considered limiting, depending on the specific application, is that an increase in stiffness entails an increase in weight. (3) The additional weight required by a low expulsion efficiency accumulator eliminates the advantage given to such gas storage systems. The high expulsion efficiency provided by this two-fluid accumulator allows for a lightweight, tightly packaged system, which can be used in conjunction with a fuel cell-based system.
Influence of water on clumped-isotope bond reordering kinetics in calcite
NASA Astrophysics Data System (ADS)
Brenner, Dana C.; Passey, Benjamin H.; Stolper, Daniel A.
2018-03-01
Oxygen self-diffusion in calcite and many other minerals is considerably faster under wet conditions relative to dry conditions. Here we investigate whether this "water effect" also holds true for solid-state isotope exchange reactions that alter the abundance of carbonate groups with multiple rare isotopes ('clumped' isotope groups) via the process of solid-state bond reordering. We present clumped-isotope reordering rates for optical calcite heated under wet, high-pressure (100 MPa) conditions. We observe only modest increases in reordering rates under such conditions compared with rates for the same material reacted in dry CO2 under low-pressure conditions. Activation energies under wet, high-pressure conditions are indistinguishable from those for dry, low-pressure conditions, while rate constants are resolvably higher (up to ∼3 times) for wet, high-pressure relative to dry, low-pressure conditions in most of our interpretations of experimental results. This contrasts with the water effect for oxygen self-diffusion in calcite, which is associated with lower activation energies, and diffusion coefficients that are ≥103 times higher compared with dry (pure CO2) conditions in the temperature range of this study (385-450 °C). The water effect for clumped-isotopes leads to calculated apparent equilibrium temperatures ("blocking temperatures") for typical geological cooling rates that are only a few degrees higher than those for dry conditions, while O self-diffusion blocking temperatures in calcite grains are ∼150-200 °C lower in wet conditions compared with dry conditions. Since clumped-isotope reordering is a distributed process that occurs throughout the mineral volume, our clumped-isotope results support the suggestion of Labotka et al. (2011) that the water effect in calcite does not involve major changes in bulk (volume) diffusivity, but rather is primarily a surface phenomenon that facilitates oxygen exchange between the calcite surface and external fluids. We explore the mechanism(s) by which clumped isotope reordering rates may be modestly increased under wet, high-pressure conditions, including changes in defect concentrations in the near surface environment due to reactions at the water-mineral interface, and lattice deformation resulting from pressurization of samples.
Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.
Gritti, Fabrice; Guiochon, Georges
2008-04-11
The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippov, A. V., E-mail: fav@triniti.ru; Dyatko, N. A.; Kostenko, A. S.
2014-11-15
The charging of dust particles in weakly ionized inert gases at atmospheric pressure has been investigated. The conditions under which the gas is ionized by an external source, a beam of fast electrons, are considered. The electron energy distribution function in argon, krypton, and xenon has been calculated for three rates of gas ionization by fast electrons: 10{sup 13}, 10{sup 14}, and 10{sup 15} cm{sup −1}. A model of dust particle charging with allowance for the nonlocal formation of the electron energy distribution function in the region of strong plasma quasi-neutrality violation around the dust particle is described. The nonlocalitymore » is taken into account in an approximation where the distribution function is a function of only the total electron energy. Comparative calculations of the dust particle charge with and without allowance for the nonlocality of the electron energy distribution function have been performed. Allowance for the nonlocality is shown to lead to a noticeable increase in the dust particle charge due to the influence of the group of hot electrons from the tail of the distribution function. It has been established that the screening constant virtually coincides with the smallest screening constant determined according to the asymptotic theory of screening with the electron transport and recombination coefficients in an unperturbed plasma.« less
Staves, M P; Wayne, R; Leopold, A C
1997-11-01
Gravity induces a polarity of cytoplasmic streaming in vertical internodal cells of Chara such that the downwardly directed stream moves faster than the upwardly directed stream. In order to determine whether the statolith theory (in which intracellular sedimenting particles are responsible for gravity sensing) or the gravitational pressure theory (in which the entire protoplast acts as the gravity sensor) best explain the gravity response in Chara internodal cells, we controlled the physical properties of the external medium, including density and osmolarity, with impermeant solutes and examined the effect on the polarity of cytoplasmic streaming. As the density of the external medium is increased, the polarity of cytoplasmic streaming decreases and finally disappears when the density of the external medium is equal to that of the cell (1015 kg/m3). A further increase in the density of the external medium causes a reversal of the gravity response. These results are consistent with the gravitational pressure theory of gravity sensing since the buoyancy of the protoplast is dependent on the difference between the density of the protoplast and the external medium, and are inconsistent with the statolith theory since the buoyancy of intracellular particles are unaffected by changes in the external medium.
NASA Technical Reports Server (NTRS)
Staves, M. P.; Wayne, R.; Leopold, A. C.
1997-01-01
Gravity induces a polarity of cytoplasmic streaming in vertical internodal cells of Chara such that the downwardly directed stream moves faster than the upwardly directed stream. In order to determine whether the statolith theory (in which intracellular sedimenting particles are responsible for gravity sensing) or the gravitational pressure theory (in which the entire protoplast acts as the gravity sensor) best explain the gravity response in Chara internodal cells, we controlled the physical properties of the external medium, including density and osmolarity, with impermeant solutes and examined the effect on the polarity of cytoplasmic streaming. As the density of the external medium is increased, the polarity of cytoplasmic streaming decreases and finally disappears when the density of the external medium is equal to that of the cell (1015 kg/m3). A further increase in the density of the external medium causes a reversal of the gravity response. These results are consistent with the gravitational pressure theory of gravity sensing since the buoyancy of the protoplast is dependent on the difference between the density of the protoplast and the external medium, and are inconsistent with the statolith theory since the buoyancy of intracellular particles are unaffected by changes in the external medium.
Aubert, A E; Denys, B G; Meno, F; Reddy, P S
1985-05-01
Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S1. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequency responses. Volume and pressure overload and positive and negative inotropic drugs were used to generate gallop sounds. Recordings were made in the control state and after the various interventions. S3 and S4 were recorded in 17 experiments each. The amplitude of the external S1 was uniformly higher than that of internal S1 and internal gallop sounds were inconspicuous. With use of Fourier transforms, the gain function was determined by comparing internal to external S1. By inverse transform, the amplitude of the internal gallop sounds was predicted from external sounds. The internal sounds of significant amplitude were predicted in many instances, but the actual recordings showed no conspicuous sounds. The absence of internal gallop sounds of expected amplitude as calculated from the external gallop sounds and the gain function derived from the comparison of internal and external S1 make it very unlikely that external gallop sounds are derived from internal sounds.
NASA Astrophysics Data System (ADS)
Peng, Z.; Day, D. A.; Stark, H.; Li, R.; Lee-Taylor, J.; Palm, B. B.; Brune, W. H.; Jimenez, J. L.
2015-11-01
Oxidation flow reactors (OFRs) using OH produced from low-pressure Hg lamps at 254 nm (OFR254) or both 185 and 254 nm (OFR185) are commonly used in atmospheric chemistry and other fields. OFR254 requires the addition of externally formed O3 since OH is formed from O3 photolysis, while OFR185 does not since O2 can be photolyzed to produce O3, and OH can also be formed from H2O photolysis. In this study, we use a plug-flow kinetic model to investigate OFR properties under a very wide range of conditions applicable to both field and laboratory studies. We show that the radical chemistry in OFRs can be characterized as a function of UV light intensity, H2O concentration, and total external OH reactivity (OHRext, e.g., from volatile organic compounds (VOCs), NOx, and SO2). OH exposure is decreased by added external OH reactivity. OFR185 is especially sensitive to this effect at low UV intensity due to low primary OH production. OFR254 can be more resilient against OH suppression at high injected O3 (e.g., 70 ppm), as a larger primary OH source from O3, as well as enhanced recycling of HO2 to OH, make external perturbations to the radical chemistry less significant. However if the external OH reactivity in OFR254 is much larger than OH reactivity from injected O3, OH suppression can reach 2 orders of magnitude. For a typical input of 7 ppm O3 (OHRO3 = 10 s-1), 10-fold OH suppression is observed at OHRext ~ 100 s-1, which is similar or lower than used in many laboratory studies. The range of modeled OH suppression for literature experiments is consistent with the measured values except for those with isoprene. The finding on OH suppression may have important implications for the interpretation of past laboratory studies, as applying OHexp measurements acquired under different conditions could lead to over a 1-order-of-magnitude error in the estimated OHexp. The uncertainties of key model outputs due to uncertainty in all rate constants and absorption cross-sections in the model are within ±25 % for OH exposure and within ±60 % for other parameters. These uncertainties are small relative to the dynamic range of outputs. Uncertainty analysis shows that most of the uncertainty is contributed by photolysis rates of O3, O2, and H2O and reactions of OH and HO2 with themselves or with some abundant species, i.e., O3 and H2O2. OHexp calculated from direct integration and estimated from SO2 decay in the model with laminar and measured residence time distributions (RTDs) are generally within a factor of 2 from the plug-flow OHexp. However, in the models with RTDs, OHexp estimated from SO2 is systematically lower than directly integrated OHexp in the case of significant SO2 consumption. We thus recommended using OHexp estimated from the decay of the species under study when possible, to obtain the most appropriate information on photochemical aging in the OFR. Using HOx-recycling vs. destructive external OH reactivity only leads to small changes in OHexp under most conditions. Changing the identity (rate constant) of external OH reactants can result in substantial changes in OHexp due to different reductions in OH suppression as the reactant is consumed. We also report two equations for estimating OH exposure in OFR254. We find that the equation estimating OHexp from measured O3 consumption performs better than an alternative equation that does not use it, and thus recommend measuring both input and output O3 concentrations in OFR254 experiments. This study contributes to establishing a firm and systematic understanding of the gas-phase HOx and Ox chemistry in these reactors, and enables better experiment planning and interpretation as well as improved design of future reactors.
Peng, Z.; Day, D. A.; Stark, H.; ...
2015-11-20
Oxidation flow reactors (OFRs) using OH produced from low-pressure Hg lamps at 254 nm (OFR254) or both 185 and 254 nm (OFR185) are commonly used in atmospheric chemistry and other fields. OFR254 requires the addition of externally formed O 3 since OH is formed from O 3 photolysis, while OFR185 does not since O 2 can be photolyzed to produce O 3, and OH can also be formed from H 2O photolysis. In this study, we use a plug-flow kinetic model to investigate OFR properties under a very wide range of conditions applicable to both field and laboratory studies. Wemore » show that the radical chemistry in OFRs can be characterized as a function of UV light intensity, H 2O concentration, and total external OH reactivity (OHR ext, e.g., from volatile organic compounds (VOCs), NO x, and SO 2). OH exposure is decreased by added external OH reactivity. OFR185 is especially sensitive to this effect at low UV intensity due to low primary OH production. OFR254 can be more resilient against OH suppression at high injected O 3 (e.g., 70 ppm), as a larger primary OH source from O 3, as well as enhanced recycling of HO 2 to OH, make external perturbations to the radical chemistry less significant. However if the external OH reactivity in OFR254 is much larger than OH reactivity from injected O 3, OH suppression can reach 2 orders of magnitude. For a typical input of 7 ppm O 3 (OHR O3 = 10 s –1), 10-fold OH suppression is observed at OHR ext ~ 100 s –1, which is similar or lower than used in many laboratory studies. The range of modeled OH suppression for literature experiments is consistent with the measured values except for those with isoprene. The finding on OH suppression may have important implications for the interpretation of past laboratory studies, as applying OH exp measurements acquired under different conditions could lead to over a 1-order-of-magnitude error in the estimated OH exp. The uncertainties of key model outputs due to uncertainty in all rate constants and absorption cross-sections in the model are within ±25 % for OH exposure and within ±60 % for other parameters. These uncertainties are small relative to the dynamic range of outputs. Uncertainty analysis shows that most of the uncertainty is contributed by photolysis rates of O 3, O 2, and H 2O and reactions of OH and HO 2 with themselves or with some abundant species, i.e., O 3 and H 2O 2. OH exp calculated from direct integration and estimated from SO 2 decay in the model with laminar and measured residence time distributions (RTDs) are generally within a factor of 2 from the plug-flow OH exp. However, in the models with RTDs, OH exp estimated from SO 2 is systematically lower than directly integrated OH exp in the case of significant SO 2 consumption. We thus recommended using OH exp estimated from the decay of the species under study when possible, to obtain the most appropriate information on photochemical aging in the OFR. Using HO x-recycling vs. destructive external OH reactivity only leads to small changes in OH exp under most conditions. Changing the identity (rate constant) of external OH reactants can result in substantial changes in OH exp due to different reductions in OH suppression as the reactant is consumed. We also report two equations for estimating OH exposure in OFR254. We find that the equation estimating OH exp from measured O 3 consumption performs better than an alternative equation that does not use it, and thus recommend measuring both input and output O 3 concentrations in OFR254 experiments. As a result, this study contributes to establishing a firm and systematic understanding of the gas-phase HO x and O x chemistry in these reactors, and enables better experiment planning and interpretation as well as improved design of future reactors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Z.; Day, D. A.; Stark, H.
Oxidation flow reactors (OFRs) using OH produced from low-pressure Hg lamps at 254 nm (OFR254) or both 185 and 254 nm (OFR185) are commonly used in atmospheric chemistry and other fields. OFR254 requires the addition of externally formed O 3 since OH is formed from O 3 photolysis, while OFR185 does not since O 2 can be photolyzed to produce O 3, and OH can also be formed from H 2O photolysis. In this study, we use a plug-flow kinetic model to investigate OFR properties under a very wide range of conditions applicable to both field and laboratory studies. Wemore » show that the radical chemistry in OFRs can be characterized as a function of UV light intensity, H 2O concentration, and total external OH reactivity (OHR ext, e.g., from volatile organic compounds (VOCs), NO x, and SO 2). OH exposure is decreased by added external OH reactivity. OFR185 is especially sensitive to this effect at low UV intensity due to low primary OH production. OFR254 can be more resilient against OH suppression at high injected O 3 (e.g., 70 ppm), as a larger primary OH source from O 3, as well as enhanced recycling of HO 2 to OH, make external perturbations to the radical chemistry less significant. However if the external OH reactivity in OFR254 is much larger than OH reactivity from injected O 3, OH suppression can reach 2 orders of magnitude. For a typical input of 7 ppm O 3 (OHR O3 = 10 s –1), 10-fold OH suppression is observed at OHR ext ~ 100 s –1, which is similar or lower than used in many laboratory studies. The range of modeled OH suppression for literature experiments is consistent with the measured values except for those with isoprene. The finding on OH suppression may have important implications for the interpretation of past laboratory studies, as applying OH exp measurements acquired under different conditions could lead to over a 1-order-of-magnitude error in the estimated OH exp. The uncertainties of key model outputs due to uncertainty in all rate constants and absorption cross-sections in the model are within ±25 % for OH exposure and within ±60 % for other parameters. These uncertainties are small relative to the dynamic range of outputs. Uncertainty analysis shows that most of the uncertainty is contributed by photolysis rates of O 3, O 2, and H 2O and reactions of OH and HO 2 with themselves or with some abundant species, i.e., O 3 and H 2O 2. OH exp calculated from direct integration and estimated from SO 2 decay in the model with laminar and measured residence time distributions (RTDs) are generally within a factor of 2 from the plug-flow OH exp. However, in the models with RTDs, OH exp estimated from SO 2 is systematically lower than directly integrated OH exp in the case of significant SO 2 consumption. We thus recommended using OH exp estimated from the decay of the species under study when possible, to obtain the most appropriate information on photochemical aging in the OFR. Using HO x-recycling vs. destructive external OH reactivity only leads to small changes in OH exp under most conditions. Changing the identity (rate constant) of external OH reactants can result in substantial changes in OH exp due to different reductions in OH suppression as the reactant is consumed. We also report two equations for estimating OH exposure in OFR254. We find that the equation estimating OH exp from measured O 3 consumption performs better than an alternative equation that does not use it, and thus recommend measuring both input and output O 3 concentrations in OFR254 experiments. As a result, this study contributes to establishing a firm and systematic understanding of the gas-phase HO x and O x chemistry in these reactors, and enables better experiment planning and interpretation as well as improved design of future reactors.« less
A decrease in nasal CO2 stimulates breathing in the tegu lizard.
Coates, E L; Furilla, R A; Ballam, G O; Bartlett, D
1991-10-01
Tegu lizards decrease ventilatory frequency (f) when constant CO2, as low as 0.4%, is delivered to the nasal cavities. In contrast, CO2, as high as 6%, pulsed into the nasal cavities during the expiratory phase of the breathing cycle does not alter f. The purpose of the present study was to investigate further the effect of nasal CO2 pattern on f in tegu lizards. Specifically, we tested: (1) whether f was affected by CO2 delivered to the nasal cavities during the inspiratory phase of the breathing cycle, and (2) whether pulsed decreases in nasal CO2 from 4% to 2% and from 4% to 0% would remove the f inhibition caused by constant nasal CO2. Ventilation was measured using a pneumotachograph and pressure transducer in-line with an endotracheal T-tube inserted through the glottis. CO2 was delivered to the nasal cavities through small tubes inserted into the external nares. Ventilatory frequency was not significantly altered when 4% CO2 was pulsed into the nasal cavities during inspiration. Dropping the CO2 in the nasal cavities from 4% to 0% at either 15 cycles/min (0.25 Hz) or for one cycle stimulated breathing. There was no significant difference between the f response to a drop in CO2 from 4% to 0% and that to a drop in CO2 from 4% to 2%. The failure to link the phasic CO2 ventilatory response to a phase in the respiratory cycle indicates that the nasal CO2 receptors do not participate in the breath-by-breath regulation of breathing in these lizards. The observation that small decreases in nasal CO2 abolished the f inhibition caused by constant nasal CO2 provides further evidence for the ability of the nasal CO2 receptors to distinguish between pulsed and constant CO2.
ERIC Educational Resources Information Center
Christophersen, Knut-Andreas; Elstad, Eyvind; Turmo, Are
2012-01-01
This article focuses on the comparison of organizational antecedents of teachers' fostering of students' effort in two quite different accountability regimes: one management regime with an external-accountability system and one with no external accountability devices. The methodology involves cross-sectional surveys from two different management…
Haemodynamic and energetic properties of stunned myocardium in rabbit hearts.
Schipke, J. D.; Korbmacher, B.; Dorszewski, A.; Selcan, G.; Sunderdiek, U.; Arnold, G.
1996-01-01
OBJECTIVE--To amplify the description of myocardial stunning. DESIGN--Control versus 30 min after a 20 min no flow ischaemia. EXPERIMENTAL ANIMALS--15 isolated rabbit hearts perfused with erythrocyte suspension. MAIN OUTCOME MEASURES--Left ventricular systolic function in terms of aortic flow, peak systolic pressure (LVPmax), dP/dtmax, and the end systolic pressure-volume relation (ESPVR); early relaxation from dP/dtmin and rate of left ventricular pressure decay (tau). Passive properties: ventricular and myocardial stiffness. Coronary resistance from coronary blood flow and perfusion pressure. Total myocardial oxygen consumption (MVo2tot). Total mechanical energy via pressure-volume area (PVA). Contractile efficiency (Econ) and MVo2 of the unloaded contracting heart (MVo2unl). External mechanical efficiency (Eext) from stroke work and MVo2tot. RESULTS--Systolic variables in stunned myocardium were significantly decreased (mean (SD)): aortic flow: 38 (13) v 9 (11) ml/min; LVPmax: 112 (19) v 74 (18) mm Hg; dP/dtmax: 1475 (400) v 1075 (275) mm Hg/s. ESPVR was not significantly decreased, at 138 (73) v 125 (58) mm Hg/ml, but the volume axis intercept was shifted rightward: 0.30 (0.37) v 0.65 (0.25) ml. Likewise, early relaxation was impaired: dP/dtmin (-1275 (250) v -975 (250) mm Hg/s) and tau (37 (7) v 46 (10) ms). LVPed was significantly decreased at 19 (12) v 12 (7) mm Hg, and both the ventricular (end diastolic pressure-volume relation) and the myocardial stiffness (constant k) were increased by 75% and 31%, respectively. Coronary resistance increased non-significantly from 0.83 (0.31) to 1.04 (0.41) mm Hg/(ml/min/100 g). Decreases in PVA (570 (280) v 270 (200) mm Hg.ml/100 g), MVo2tot (40 (9) v 34 (8) microliters/beat/100 g), and MVo2unl (26 (9) v 22 (6) microliters/beat/100 g) did not reach significance, in contrast to significant decreases in Econ (31 (18) v 14 (7)%) and Eext (0.75 (0.29) v 0.18 (0.25) arbitrary units). CONCLUSIONS--Ventricular systolic function is decreased after brief episodes of ischaemia. The decrease in diastolic function probably amplifies the systolic deterioration during myocardial stunning. Passive diastolic properties are also changed, shown by increases in both ventricular and myocardial stiffness. The increase in coronary resistance indicates stunning at the vascular level which could limit oxygen supply. With maintained MVo2tot during stunning, external efficiency is decreased. Possible candidates for this metabolic stunning are inadequate excitation-contraction coupling and disturbed O2 utilisation by the contractile apparatus. Images PMID:8624873
Physics-Based Fragment Acceleration Modeling for Pressurized Tank Burst Risk Assessments
NASA Technical Reports Server (NTRS)
Manning, Ted A.; Lawrence, Scott L.
2014-01-01
As part of comprehensive efforts to develop physics-based risk assessment techniques for space systems at NASA, coupled computational fluid and rigid body dynamic simulations were carried out to investigate the flow mechanisms that accelerate tank fragments in bursting pressurized vessels. Simulations of several configurations were compared to analyses based on the industry-standard Baker explosion model, and were used to formulate an improved version of the model. The standard model, which neglects an external fluid, was found to agree best with simulation results only in configurations where the internal-to-external pressure ratio is very high and fragment curvature is small. The improved model introduces terms that accommodate an external fluid and better account for variations based on circumferential fragment count. Physics-based analysis was critical in increasing the model's range of applicability. The improved tank burst model can be used to produce more accurate risk assessments of space vehicle failure modes that involve high-speed debris, such as exploding propellant tanks and bursting rocket engines.
Bifurcation theory applied to buckling states of a cylindrical shell
NASA Astrophysics Data System (ADS)
Chaskalovic, J.; Naili, S.
1995-01-01
Veins, bronchii, and many other vessels in the human body are flexible enough to be capable of collapse if submitted to suitable applied external and internal loads. One way to describe this phenomenon is to consider an inextensible elastic and infinite tube, with a circular cross section in the reference configuration, subjected to a uniform external pressure. In this paper, we establish that the nonlinear equilibrium equation for this model has nontrivial solutions which appear for critical values of the pressure. To this end, the tools we use are the Liapunov-Schmidt decomposition and the bifurcation theorem for simple multiplicity. We conclude with the bifurcation diagram, showing the dependence between the cross-sectional area and the pressure.
On the Numerical Solution of the Integral Equation Formulation for Transient Structural Synthesis
2014-09-01
stiffness modification. mass ( ) 1 (2.2 ), spring constant ( ) 100 / 6.9 lbm kg lb k N m ft 2) A SDOF mass-spring system with an...externally applied periodic excitation, subjected to a stiffness modification. mass ( ) 1 (2.2 ), spring constant ( ) 100 / 6.9 lbm kg lb k N m ft...spring. mass ( ) 1 (2.2 ), spring constant ( ) 100 / 6.9 lbm kg lb k N m ft 4) A generalized MDOF cantilevered aluminum beam with
Modeling the pyrolysis study of non-charring polymers under reduced pressure environments
NASA Astrophysics Data System (ADS)
Zong, Ruowen; Kang, Ruxue; Hu, Yanghui; Zhi, Youran
2018-04-01
In order to study the pyrolysis of non-charring polymers under reduced pressure environments, a series of experiments based on black acrylonitrile butadiene styrene (ABS) was conducted in a reduced pressure chamber under different external heat fluxes. The temperatures of the top surface and the bottom of the sample and the mass loss during the whole process were measured in real time. A one-dimensional numerical model was developed to predict the top surface and the bottom surface temperatures of ABS during the pyrolysis at different reduced pressures and external heat fluxes, and the model was validated by the experimental data. The results of the study indicate that the profiles of the top surface and the bottom surface temperatures are different at different pressures and heat fluxes. The temperature and the mass loss rate of the sample under a lower heat flux decreased significantly as the pressure was increased. However, under a higher heat flux, the temperature and the mass loss rate showed little sensitivity to the pressure. The simulated results fitted the experimental results better at the higher heat flux than at the lower heat flux.
Weston, Ralph E; Nguyen, Thanh Lam; Stanton, John F; Barker, John R
2013-02-07
Ab initio microcanonical rate constants were computed using Semi-Classical Transition State Theory (SCTST) and used in two master equation formulations (1D, depending on active energy with centrifugal corrections, and 2D, depending on total energy and angular momentum) to compute temperature-dependent rate constants for the title reactions using a potential energy surface obtained by sophisticated ab initio calculations. The 2D master equation was used at the P = 0 and P = ∞ limits, while the 1D master equation with centrifugal corrections and an empirical energy transfer parameter could be used over the entire pressure range. Rate constants were computed for 75 K ≤ T ≤ 2500 K and 0 ≤ [He] ≤ 10(23) cm(-3). For all temperatures and pressures important for combustion and for the terrestrial atmosphere, the agreement with the experimental rate constants is very good, but at very high pressures and T ≤ 200 K, the theoretical rate constants are significantly smaller than the experimental values. This effect is possibly due to the presence in the experiments of dimers and prereactive complexes, which were not included in the model calculations. The computed H/D kinetic isotope effects are in acceptable agreement with experimental data, which show considerable scatter. Overall, the agreement between experimental and theoretical H/D kinetic isotope effects is much better than in previous work, and an assumption of non-RRKM behavior does not appear to be needed to reproduce experimental observations.
Keromnes, Alan; Metcalfe, Wayne K.; Heufer, Karl A.; ...
2013-03-12
The oxidation of syngas mixtures was investigated experimentally and simulated with an updated chemical kinetic model. Ignition delay times for H 2/CO/O 2/N 2/Ar mixtures have been measured using two rapid compression machines and shock tubes at pressures from 1 to 70 bar, over a temperature range of 914–2220 K and at equivalence ratios from 0.1 to 4.0. Results show a strong dependence of ignition times on temperature and pressure at the end of the compression; ignition delays decrease with increasing temperature, pressure, and equivalence ratio. The reactivity of the syngas mixtures was found to be governed by hydrogen chemistrymore » for CO concentrations lower than 50% in the fuel mixture. For higher CO concentrations, an inhibiting effect of CO was observed. Flame speeds were measured in helium for syngas mixtures with a high CO content and at elevated pressures of 5 and 10 atm using the spherically expanding flame method. A detailed chemical kinetic mechanism for hydrogen and H 2/CO (syngas) mixtures has been updated, rate constants have been adjusted to reflect new experimental information obtained at high pressures and new rate constant values recently published in the literature. Experimental results for ignition delay times and flame speeds have been compared with predictions using our newly revised chemical kinetic mechanism, and good agreement was observed. In the mechanism validation, particular emphasis is placed on predicting experimental data at high pressures (up to 70 bar) and intermediate- to high-temperature conditions, particularly important for applications in internal combustion engines and gas turbines. The reaction sequence H 2 + HO˙ 2 ↔ H˙+H 2O 2 followed by H 2O 2(+M) ↔ O˙H+O˙H(+M) was found to play a key role in hydrogen ignition under high-pressure and intermediate-temperature conditions. The rate constant for H 2+HO˙ 2 showed strong sensitivity to high-pressure ignition times and has considerable uncertainty, based on literature values. As a result, a rate constant for this reaction is recommended based on available literature values and on our mechanism validation.« less
1991-12-01
gradient will be presented. -Finally, a brief discussion of various piezoelectric materials will be presented, including Rochelle salt, quartz, barium...consideringr a microscopic-level dipole arrangement. The strain induced by ain external force or a tempem at ure gradient changes hie orientation of the...pyroelectric materials, an externally applied temperature gradient can be related to the resulting polarization by a l)yroelectric * constant.1 p (130
Costa, Ana Paula Araujo; Lima, Aline Maria Vasconcelos; da Silva, Luiz Henrique; de Oliveira Alves Carvalho, Rosângela; do Amaral, Andréia Vitor Couto; Borges, Naida Cristina
2016-07-22
It has been proposed that sildenafil citrate can increase ocular blood flow, and that this property can be used to treat ocular disorders that involve reflex vasoconstriction. This study therefore proposes to ascertain the vasodilator effect of the drug on retrobulbar circulation in healthy rabbits. For this matter rabbits treated with sildenafil citrate or saline solution had their intraocular pressure (IOP), mean arterial pressure (MAP), ocular perfusion pressure (OPP) and color Doppler imaging of the external ophthalmic artery measured prior to treatment and on days one (moment M1), seven (when M2), fourteen (moment M3), twenty-one (moment M4), and thirty (moment M5) of treatment. The MAP and OPP values of treated group were lower than those of control group at all times, and the mean values differed statistically at moments M1 (S = 71.52 mmHg, C = 84.76 mmHg, p = 0.0356) and M5 (S = 71.38 mmHg, C = 85.52 mmHg, p = 0.0252). The IOP and color Doppler values of the external ophthalmic artery did not differ between tested groups. The dose of 10 mg of sildenafil citrate administered to healthy rabbits causes systemic vasodilation and consequently lower values of MAP and OPP. However, it does not induce changes in IOP and retrobulbar hemodynamics identifiable by color Doppler assessment of the external ophthalmic artery.
First-principles calculations for elastic properties of OsB 2 under pressure
NASA Astrophysics Data System (ADS)
Yang, Jun-Wei; Chen, Xiang-Rong; Luo, Fen; Ji, Guang-Fu
2009-11-01
The structure, elastic properties and elastic anisotropy of orthorhombic OsB 2 are investigated by density functional theory method with the ultrasoft pseudopotential scheme in the frame of the generalized gradient approximation (GGA) as well as local density approximation (LDA). The obtained structural parameters, elastic constants, elastic anisotropy and Debye temperature for OsB 2 under pressure are consistent with the available experimental data and other theoretical results. It is found that the elastic constants, bulk modulus and Debye temperature of OsB 2 tend to increase with increasing pressure. It is predicted that OsB 2 is not a superhard material from our calculations.
NASA Technical Reports Server (NTRS)
Weber, L. A.
1977-01-01
The results of an experimental program are presented in the form of PVT data in the temperature range 58 to 300 K at pressures up to 800 bar. Tables of the derived thermodynamic properties on isobars to 1000 bar are given, including density, internal energy, enthalpy, entropy, specific heats at constant volume and constant pressure, velocity of sound, and the surface derivatives (delta P/delta T) sub rho and (delta P/delta Rho) sub T. Auxiliary tables in engineering units are also given. The accuracy of the data is discussed and comparisons are made with previous data.
Ab initio calculations for the elastic properties of magnesium under pressure
NASA Astrophysics Data System (ADS)
Sin'Ko, G. V.; Smirnov, N. A.
2009-09-01
Results of ab initio calculations of the elastic constants for the hcp, bcc, double hcp (dhcp), and fcc magnesium in a wide range of pressures are presented. The calculated elastic constants are compared with available experimental and theoretical data. We discuss the effect of the electron topological transition that occurs when the hcp structure is compressed on results of calculations and consider possibility of observing the hcp→dhcp transition on the magnesium Hugoniot.
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.; Kaemming, Thomas A.
2012-01-01
A methodology is described whereby the work extracted by a turbine exposed to the fundamentally nonuniform flowfield from a representative pressure gain combustor (PGC) may be assessed. The method uses an idealized constant volume cycle, often referred to as an Atkinson or Humphrey cycle, to model the PGC. Output from this model is used as input to a scalable turbine efficiency function (i.e., a map), which in turn allows for the calculation of useful work throughout the cycle. Integration over the entire cycle yields mass-averaged work extraction. The unsteady turbine work extraction is compared to steady work extraction calculations based on various averaging techniques for characterizing the combustor exit pressure and temperature. It is found that averages associated with momentum flux (as opposed to entropy or kinetic energy) provide the best match. This result suggests that momentum-based averaging is the most appropriate figure-of-merit to use as a PGC performance metric. Using the mass-averaged work extraction methodology, it is also found that the design turbine pressure ratio for maximum work extraction is significantly higher than that for a turbine fed by a constant pressure combustor with similar inlet conditions and equivalence ratio. Limited results are presented whereby the constant volume cycle is replaced by output from a detonation-based PGC simulation. The results in terms of averaging techniques and design pressure ratio are similar.
Methods and apparatus for determining cardiac output
NASA Technical Reports Server (NTRS)
Cohen, Richard J. (Inventor); Sherman, Derin A. (Inventor); Mukkamala, Ramakrishna (Inventor)
2010-01-01
The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.
High Pressure Crystalline Structure and Resistance of Vanadium Dioxide to 13.5 GPa
NASA Astrophysics Data System (ADS)
Brady, Nathaniel; Appavoo, Kannatassen; Montgomery, Jeffery; Vohra, Yogesh; Haglund, Richard; Hilton, David
2013-03-01
We have investigated the insulator-to-metal transition in thin film vanadium dioxide as a function of pressure at ambient temperature using a designer diamond anvil cell (DAC). Four-point probe resistance measurements show a monotonic decrease over the entire pressure range studied with no significant discontinuity. High-pressure X-ray diffraction measurements observe an M1 (P21 / c) phase at 0 GPa, an M2 (C2/m) phase from 0.8 GPa to 1.1 GPa, and a reentrant M1 phase from 1.1 GPa to 13.5 GPa. Crystal refinement above 1.1 GPa shows a monotonically decreasing a, b and c lattice constants and a minimum in the monoclinic angle, β, near 8.5 +/-0.5 GPa. The atomic positions show that the first V-V nearest neighbor distance (d) decreases over the entire pressure range, the second nearest neighbor distance (s) increases until 5 GPa after which it is constant with s ~ f ~3.2 Å. The next most closely spaced V-V distance (f), which corresponds to V atoms in different unit cells, is approximately constant across the entire pressure range measured. NB and JM acknowledge support from the US Dept. Education GAANN Fellowship (P200A090143). KA and RH acknowledge support from the Office of Science, US Department of Energy (DE- FG02-01ER45916).
Capillary pumping independent of the liquid surface energy and viscosity
NASA Astrophysics Data System (ADS)
Guo, Weijin; Hansson, Jonas; van der Wijngaart, Wouter
2018-03-01
Capillary pumping is an attractive means of liquid actuation because it is a passive mechanism, i.e., it does not rely on an external energy supply during operation. The capillary flow rate generally depends on the liquid sample viscosity and surface energy. This poses a problem for capillary-driven systems that rely on a predictable flow rate and for which the sample viscosity or surface energy are not precisely known. Here, we introduce the capillary pumping of sample liquids with a flow rate that is constant in time and independent of the sample viscosity and sample surface energy. These features are enabled by a design in which a well-characterized pump liquid is capillarily imbibed into the downstream section of the pump and thereby pulls the unknown sample liquid into the upstream pump section. The downstream pump geometry is designed to exert a Laplace pressure and fluidic resistance that are substantially larger than those exerted by the upstream pump geometry on the sample liquid. Hence, the influence of the unknown sample liquid on the flow rate is negligible. We experimentally tested pumps of the new design with a variety of sample liquids, including water, different samples of whole blood, different samples of urine, isopropanol, mineral oil, and glycerol. The capillary filling speeds of these liquids vary by more than a factor 1000 when imbibed to a standard constant cross-section glass capillary. In our new pump design, 20 filling tests involving these liquid samples with vastly different properties resulted in a constant volumetric flow rate in the range of 20.96-24.76 μL/min. We expect this novel capillary design to have immediate applications in lab-on-a-chip systems and diagnostic devices.
Automated cuff pressure modulation: a novel device to reduce endotracheal tube injury.
Chadha, Neil K; Gordin, Arie; Luginbuehl, Igor; Patterson, Greg; Campisi, Paolo; Taylor, Glenn; Forte, Vito
2011-01-01
To assess whether dynamically modulating endotracheal tube (ETT) cuff pressure, by decreasing it during each ventilatory cycle instead of maintaining a constant level, would reduce the extent of intubation-related laryngotracheal injury. Single-blind, randomized controlled animal study using a previously validated live porcine model of accelerated intubation-related tracheal injury. Animal research facility. Ten piglets (weight, 16-20 kg each) were anesthetized and underwent intubation using a cuffed ETT. The animals were randomized into the following 2 groups: 5 pigs had a novel device to modulate their cuff pressure from 25 cm H₂O during inspiration to 7 cm H₂O during expiration, and 5 pigs had a constant cuff pressure of 25 cm H₂O. Both groups underwent ventilation under hypoxic conditions for 4 hours. Laryngotracheal mucosal injury after blinded histopathological assessment. The modulated-pressure group showed significantly less overall laryngotracheal damage than the constant-pressure group (mean grades, 1.2 vs 2.1; P < .001). Subglottic damage and tracheal damage were significantly less severe in the modulated-pressure group (mean grades, 1.0 vs 2.2; P < .001, and 1.9 vs 3.2; P < .001, respectively). There was no significant difference in glottic or supraglottic damage between the groups (P = .06 and .27, respectively). This novel device reduces the risk of subglottic and tracheal injury by modulating ETT cuff pressure in synchronization with the ventilatory cycle. This finding could have far-reaching implications for reducing the risk of airway injury in patients undergoing long-term intubation. Further clinical study of this device is warranted.
Microfluidic oscillators with widely tunable periods
Kim, Sung-Jin; Yokokawa, Ryuji; Takayama, Shuichi
2013-01-01
We present experiments and theory of a constant flow-driven microfluidic oscillator with widely tunable oscillation periods. This oscillator converts two constant input-flows from a syringe pump into an alternating, periodic output-flow with oscillation periods that can be adjusted to between 0.3 s to 4.1 h by tuning an external membrane capacitor. This capacitor allows multiple adjustable periods at a given input flow-rate, thus providing great flexibility in device operation. Also, we show that a sufficiently large external capacitance, relative to the internal capacitance of the microfluidic valve itself, is a critical requirement for oscillation. These widely tunable microfluidic oscillators are envisioned to be broadly useful for the study of biological rhythms, as on-chip timing sources for microfluidic logic circuits, and other applications that require variation in timed flow switching. PMID:23429765
Reconstruction of shifting elbow joint compliant characteristics during fast and slow movements.
Latash, M L; Gottlieb, G L
1991-01-01
The purpose of this study was to experimentally investigate the applicability of the equilibrium-point hypothesis to the dynamics of single-joint movements. Subjects were trained to perform relatively slow (movement time 600-1000 ms) or fast (movement time 200-300 ms) single-joint elbow flexion movements against a constant extending torque bias. They were instructed to reproduce the same time pattern of central motor command for a series of movements when the external torque could slowly and unpredictably increase, decrease, or remain constant. For fast movements, the total muscle torque was calculated as a sum of external and inertial components. Analysis of the data allowed reconstruction of the elbow joint compliant characteristics at different times during execution of the learned motor command. "Virtual" trajectories of the movements, representing time-varying changes in a central control parameter, were reconstructed and compared with the "actual" trajectories. For slow movements, the actual trajectories lagged behind the virtual ones. There were no consistent changes in the joint stiffness during slow movements. Similar analysis of experiments without voluntary movements demonstrated a lack of changes in the central parameters, supporting the assumption that the subjects were able to keep the same central motor command in spite of externally imposed unexpected torque perturbations. For the fast movements, the virtual trajectories were N-shaped, and the joint stiffness demonstrated a considerable increase near the middle of the movement. These findings contradict an hypothesis of monotonic joint compliant characteristic translation at a nearly constant rate during such movements.
Preventing collapse of external auditory meatus during audiometry.
Pearlman, R C
1975-11-01
Occlusion of the external auditory meatus resulting from earphone pressure can produce a pseudoconductive hearing loss. I describe a method for detecting ear canal collapse by otoscopy and I suggest a method of correcting the problem with a polyethylene tube prosthesis.
46 CFR 64.53 - Information plate for MPTs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... name. (3) Date of manufacture. (4) Serial number of tank. (5) Maximum allowable working pressure in psig. (6) Test pressure in psig. (7) External-pressure rating in psig. (8) Total capacity in gallons... 122 °F. (12) Date of hydrostatic test. [CGD 84-043, 55 FR 37410, Sept. 11, 1990] ...
Gas pressure in sealed electrochemical cells measured externally
NASA Technical Reports Server (NTRS)
Sherfey, J. M.
1967-01-01
Piezoresistive transducer measures gas pressure inside sealed secondary electrochemical cells without breaking the seal. This method is based on the observed fact that the force exerted by the cell faces on the clamp tightening them against the transducer is a function of the gas pressure inside the cell.
14 CFR 23.365 - Pressurized cabin loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... stress concentrations, must be accounted for. (c) If landings may be made with the cabin pressurized... be designed for the effects of sudden release of pressure in any compartment with external doors or windows. This condition must be investigated for the effects of failure of the largest opening in the...
Twin-spool turbopumps for ''low'' net positive suction pressure operations
NASA Technical Reports Server (NTRS)
Bair, E. K.; Campbell, W. E.; Ford, O. I.
1970-01-01
Modified single-shaft turbopump incorporates inducer and main pump, each separately driven at different speeds through coaxial-shaft arrangement. Inducer operates at low speed for low net positive suction pressure, main pump operates at high speed to generate high pressure. This arrangement requires no external control for the inducer.
Apparatus for in-situ calibration of instruments that measure fluid depth
Campbell, M.D.
1994-01-11
The present invention provides a method and apparatus for in-situ calibration of distance measuring equipment. The method comprises obtaining a first distance measurement in a first location, then obtaining at least one other distance measurement in at least one other location of a precisely known distance from the first location, and calculating a calibration constant. The method is applied specifically to calculating a calibration constant for obtaining fluid level and embodied in an apparatus using a pressure transducer and a spacer of precisely known length. The calibration constant is used to calculate the depth of a fluid from subsequent single pressure measurements at any submerged position. 8 figures.
Effects of external pressure on the performance and ageing of single-layer lithium-ion pouch cells
NASA Astrophysics Data System (ADS)
Mussa, Abdilbari Shifa; Klett, Matilda; Lindbergh, Göran; Lindström, Rakel Wreland
2018-05-01
The effects of external compression on the performance and ageing of NMC(1/3)/Graphite single-layer Li-ion pouch cells are investigated using a spring-loaded fixture. The influence of pressure (0.66, 0.99, 1.32, and 1.98 MPa) on impedance is characterized in fresh cells that are subsequently cycled at the given pressure levels. The aged cells are analyzed for capacity fade and impedance rise at the cell and electrode level. The effect of pressure distribution that may occur in large-format cells or in a battery pack is simulated using parallel connected cells. The results show that the kinetic and mass transport resistance increases with pressure in a fresh cell. An optimum pressure around 1.3 MPa is shown to be beneficial to reduce cyclable-lithium loss during cycling. The minor active mass losses observed in the electrodes are independent of the ageing pressure, whereas ageing pressure affects the charge transfer resistance of both NMC and graphite electrodes and the ohmic resistance of the cell. Pressure distribution induces current distribution but the enhanced current throughput at lower pressures cell does not accelerate its ageing. Conclusions from this work can explain some of the discrepancies in non-uniform ageing reported in the literature and indicate coupling between electrochemistry and mechanics.
Fluidically Controlled Cargo Hook
1975-03-01
Final Breadboard Fluidic Circuit IT 6 External Cargo Handling System - Cü-Sk Type Aircraft 18 7 Back Pressure Switch Response Time - Switching...On 20 8 Back Pressure Switch Response Time - Switching Off 21 9 Hook Actuator - Pressure Rise Rate 22 10 Breadboard Fluidic System Component...LINE LENGTH* FT Figure 7« Back. Pressure Switch Response Time - Switching On. ! TABLE k. INTERFACE VALVE SIGNAL TIME
Biofeedback With Implanted Blood-Pressure Device
NASA Technical Reports Server (NTRS)
Rischell, Robert E.
1988-01-01
Additional uses found for equipment described in "Implanted Blood-Pressure-Measuring Device" (GSC-13042). Implanted with device electronic circuitry that measures, interprets, and transmits data via inductive link through patient's skin to external receiver. Receiver includes audible alarm generator activated when patient's blood pressure exceeds predetermined threshold. Also included in receiver a blood-pressure display, recorder, or both, for use by patient or physician.
NASA Astrophysics Data System (ADS)
Lloyd, Alexander S.; Ruprecht, Philipp; Hauri, Erik H.; Rose, William; Gonnermann, Helge M.; Plank, Terry
2014-08-01
The explosivity of volcanic eruptions is governed in part by the rate at which magma ascends and degasses. Because the time scales of eruptive processes can be exceptionally fast relative to standard geochronometers, magma ascent rate remains difficult to quantify. Here we use as a chronometer concentration gradients of volatile species along open melt embayments within olivine crystals. Continuous degassing of the external melt during magma ascent results in diffusion of volatile species from embayment interiors to the bubble located at their outlets. The novel aspect of this study is the measurement of concentration gradients in five volatile elements (CO2, H2O, S, Cl, F) at fine-scale (5-10 μm) using the NanoSIMS. The wide range in diffusivity and solubility of these different volatiles provides multiple constraints on ascent timescales over a range of depths. We focus on four 100-200 μm, olivine-hosted embayments erupted on October 17, 1974 during the sub-Plinian eruption of Volcán de Fuego. H2O, CO2, and S all decrease toward the embayment outlet bubble, while F and Cl increase or remain roughly constant. Compared to an extensive melt inclusion suite from the same day of the eruption, the embayments have lost both H2O and CO2 throughout the entire length of the embayment. We fit the profiles with a 1-D numerical diffusion model that allows varying diffusivities and external melt concentrations as a function of pressure. Assuming a constant decompression rate from the magma storage region at approximately 220 MPa to the surface, H2O, CO2 and S profiles for all embayments can be fit with a relatively narrow range in decompression rates of 0.3-0.5 MPa/s, equivalent to 11-17 m/s ascent velocity and an 8 to 12 minute duration of magma ascent from ~ 10 km depth. A two stage decompression model takes advantage of the different depth ranges over which CO2 and H2O degas, and produces good fits given an initial stage of slow decompression (0.05-0.3 MPa/s) at high pressure (> 145 MPa), with similar decompression rates to the single-stage model for the shallower stage. The magma ascent rates reported here are among the first for explosive basaltic eruptions and demonstrate the potential of the embayment method for quantifying magmatic timescales associated with eruptions of different vigor.
Influence of the pressure dependent coefficient of friction on deep drawing springback predictions
NASA Astrophysics Data System (ADS)
Gil, Imanol; Galdos, Lander; Mendiguren, Joseba; Mugarra, Endika; Sáenz de Argandoña, Eneko
2016-10-01
This research studies the effect of considering an advanced variable friction coefficient on the springback prediction of stamping processes. Traditional constant coefficient of friction considerations are being replaced by more advanced friction coefficient definitions. The aim of this work is to show the influence of defining a pressure dependent friction coefficient on numerical springback predictions of a DX54D mild steel, a HSLA380 and a DP780 high strength steel. The pressure dependent friction model of each material was fitted to the experimental data obtained by Strip Drawing tests. Then, these friction models were implemented in a numerical simulation of a drawing process of an industrial automotive part. The results showed important differences between defining a pressure dependent friction coefficient or a constant friction coefficient.
NASA Technical Reports Server (NTRS)
Magi, M.; Freivald, A.; Andersson, I.; Ericsson, U.
1981-01-01
Various hydrostatic power transmission systems for automotive applications with power supply at constant pressure and unrestricted flow and with a Volvo Flygmotor variable displacement motor as the principal unit were investigated. Two most promising concepts were analyzed in detail and their main components optimized for minimum power loss at the EPA Urban Driving Cycle. The best fuel consumption is less than 10 lit. per 100 kM for a 1542 kG vehicle with a hydrostatic motor and a two speed gear box in series (braking power not recovered). Realistic system pressure affects the fuel consumption just slightly, but the package volume/weight drastically. Back pressure increases losses significantly. Special attention was paid to description of the behavior and modeling of the losses of variable displacement hydrostatic machines.
Thermal equation of state of silicon carbide
NASA Astrophysics Data System (ADS)
Wang, Yuejian; Liu, Zhi T. Y.; Khare, Sanjay V.; Collins, Sean Andrew; Zhang, Jianzhong; Wang, Liping; Zhao, Yusheng
2016-02-01
A large volume press coupled with in-situ energy-dispersive synchrotron X-ray was used to probe the change of silicon carbide (SiC) under high pressure and temperature (P-T) up to 8.1 GPa and 1100 K. The obtained pressure-volume-temperature data were fitted to a modified high-T Birch-Murnaghan equation of state, yielding values of a series of thermo-elastic parameters, such as the ambient bulk modulus KTo = 237(2) GPa, temperature derivative of the bulk modulus at a constant pressure (∂K/∂T)P = -0.037(4) GPa K-1, volumetric thermal expansivity α(0, T) = a + bT with a = 5.77(1) × 10-6 K-1 and b = 1.36(2) × 10-8 K-2, and pressure derivative of the thermal expansion at a constant temperature (∂α/∂P)T = 6.53 ± 0.64 × 10-7 K-1 GPa-1. Furthermore, we found the temperature derivative of the bulk modulus at a constant volume, (∂KT/∂T)V, equal to -0.028(4) GPa K-1 by using a thermal pressure approach. In addition, the elastic properties of SiC were determined by density functional theory through the calculation of Helmholtz free energy. The computed results generally agree well with the experimentally determined values.
Observation of pressure variation in the cavitation region of submerged journal bearings
NASA Technical Reports Server (NTRS)
Etsion, I.; Ludwig, L. P.
1980-01-01
Visual observations and pressure measurements in the cavitation zone of a submerged journal bearing are described. Tests were performed at various shaft speeds and ambient pressure levels. Some photographs of the cavitation region are presented showing strong reverse flow at the downstream end of the region. Pressure profiles are presented showing significant pressure variations inside the cavitation zone, contrary to common assumptions of constant cavitation pressure.
Razus, D; Brinzea, V; Mitu, M; Movileanu, C; Oancea, D
2011-06-15
The maximum rates of pressure rise during closed vessel explosions of propane-air mixtures are reported, for systems with various initial concentrations, pressures and temperatures ([C(3)H(8)]=2.50-6.20 vol.%, p(0)=0.3-1.3 bar; T(0)=298-423 K). Experiments were performed in a spherical vessel (Φ=10 cm) with central ignition. The deflagration (severity) index K(G), calculated from experimental values of maximum rates of pressure rise is examined against the adiabatic deflagration index, K(G, ad), computed from normal burning velocities and peak explosion pressures. At constant temperature and fuel/oxygen ratio, both the maximum rates of pressure rise and the deflagration indices are linear functions of total initial pressure, as reported for other fuel-air mixtures. At constant initial pressure and composition, the maximum rates of pressure rise and deflagration indices are slightly influenced by the initial temperature; some influence of the initial temperature on maximum rates of pressure rise is observed only for propane-air mixtures far from stoichiometric composition. The differentiated temperature influence on the normal burning velocities and the peak explosion pressures might explain this behaviour. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Akyuzlu, K. M.; Jones, S.; Meredith, T.
1993-01-01
Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.
Wang, Jun; Apte, Pankaj A; Morris, James R; Zeng, Xiao Cheng
2013-09-21
Stockmayer fluids are a prototype model system for dipolar fluids. We have computed the freezing temperatures of Stockmayer fluids at zero pressure using three different molecular-dynamics simulation methods, namely, the superheating-undercooling method, the constant-pressure and constant-temperature two-phase coexistence method, and the constant-pressure and constant-enthalpy two-phase coexistence method. The best estimate of the freezing temperature (in reduced unit) for the Stockmayer (SM) fluid with the dimensionless dipole moment μ*=1, √2, √3 is 0.656 ± 0.001, 0.726 ± 0.002, and 0.835 ± 0.005, respectively. The freezing temperature increases with the dipolar strength. Moreover, for the first time, the solid-liquid interfacial free energies γ of the fcc (111), (110), and (100) interfaces are computed using two independent methods, namely, the cleaving-wall method and the interfacial fluctuation method. Both methods predict that the interfacial free energy increases with the dipole moment. Although the interfacial fluctuation method suggests a weaker interfacial anisotropy, particularly for strongly dipolar SM fluids, both methods predicted the same trend of interfacial anisotropy, i.e., γ100 > γ110 > γ111.
Classical spin glass system in external field with taking into account relaxation effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gevorkyan, A. S., E-mail: g_ashot@sci.am; Abajyan, H. G.
2013-08-15
We study statistical properties of disordered spin systems under the influence of an external field with taking into account relaxation effects. For description of system the spatial 1D Heisenberg spin-glass Hamiltonian is used. In addition, we suppose that interactions occur between nearest-neighboring spins and they are random. Exact solutions which define angular configuration of the spin in nodes were obtained from the equations of stationary points of Hamiltonian and the corresponding conditions for the energy local minimum. On the basis of these recurrent solutions an effective parallel algorithm is developed for simulation of stabile spin-chains of an arbitrary length. Itmore » is shown that by way of an independent order of N{sup 2} numerical simulations (where N is number of spin in each chain) it is possible to generate ensemble of spin-chains, which is completely ergodic which is equivalent to full self-averaging of spin-chains' vector polarization. Distributions of different parameters (energy, average polarization by coordinates, and spin-spin interaction constant) of unperturbed system are calculated. In particular, analytically is proved and numerically is shown, that for the Heisenberg nearest-neighboring Hamiltonian model, the distribution of spin-spin interaction constants as opposed to widely used Gauss-Edwards-Anderson distribution satisfies Levy alpha-stable distribution law. This distribution is nonanalytic function and does not have variance. In the work we have in detail studied critical properties of an ensemble depending on value of external field parameters (from amplitude and frequency) and have shown that even at weak external fields the spin-glass systemis strongly frustrated. It is shown that frustrations have fractal behavior, they are selfsimilar and do not disappear at scale decreasing of area. By the numerical computation is shown that the average polarization of spin-glass on a different coordinates can have values which can lead to catastrophes in the equation ofClausius-Mossotti for dielectric constant. In other words, for some values of external field parameter, a critical phenomenon occurs in the system which is impossible to describe by the real-valued Heisenberg spin-glass Hamiltonian. For the solution of this problem at first the complex-valued disordered Hamiltonian is used. Physically this type of extension of Hamiltonian allows to consider relaxation effects which occur in the system under the influence of an external field. On the basis of developed approach an effective parallel algorithm is developed for simulation of statistic parameters of spin-glass system under the influence of an external field.« less
Spontaneous oscillations in microfluidic networks
NASA Astrophysics Data System (ADS)
Case, Daniel; Angilella, Jean-Regis; Motter, Adilson
2017-11-01
Precisely controlling flows within microfluidic systems is often difficult which typically results in systems being heavily reliant on numerous external pumps and computers. Here, I present a simple microfluidic network that exhibits flow rate switching, bistablity, and spontaneous oscillations controlled by a single pressure. That is, by solely changing the driving pressure, it is possible to switch between an oscillating and steady flow state. Such functionality does not rely on external hardware and may even serve as an on-chip memory or timing mechanism. I use an analytic model and rigorous fluid dynamics simulations to show these results.
Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2015-01-01
A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion
Self-contained small utility system
Labinov, Solomon D.; Sand, James R.
1995-01-01
A method and apparatus is disclosed to provide a fuel efficient source of readily converted energy to an isolated or remote energy consumption facility. External heat from any of a large variety of sources is converted to an electrical, mechanical, heat or cooling form of energy. A polyatomic working fluid energized by external heat sources is dissociated to a higher gaseous energy state for expansion through a turbine prime mover. The working fluid discharge from the turbine prime mover is routed to a recouperative heat exchanger for exothermic recombination reaction heat transfer to working fluid discharged from the compressor segment of the thermodynaic cycle discharge. The heated compressor discharge fluid is thereafter further heated by the external heat source to the initial higher energy state. Under the pressure at the turbine outlet, the working fluid goes out from a recouperative heat exchanger to a superheated vapor heat exchanger where it is cooled by ambient medium down to an initial temperature of condensation. Thereafter, the working fluid is condensed to a complete liquid state in a condenser cooled by an external medium. This liquid is expanded isenthalpically down to the lowest pressure of the cycle. Under this pressure, the working fluid is evaporated to the superheated vapor state of the inlet of a compressor.
Ballast system for maintaining constant pressure in a glove box
NASA Technical Reports Server (NTRS)
Shlichta, Paul J. (Inventor)
1989-01-01
A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
Ballast system for maintaining constant pressure in a glove box
NASA Astrophysics Data System (ADS)
Shlichta, Paul J.
1989-09-01
A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
Ballast system for maintaining constant pressure in a glove box
NASA Technical Reports Server (NTRS)
Shlichta, Paul J. (Inventor)
1990-01-01
A ballast system for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.
When water does not boil at the boiling point.
Chang, Hasok
2007-03-01
Every schoolchild learns that, under standard pressure, pure water always boils at 100 degrees C. Except that it does not. By the late 18th century, pioneering scientists had already discovered great variations in the boiling temperature of water under fixed pressure. So, why have most of us been taught that the boiling point of water is constant? And, if it is not constant, how can it be used as a 'fixed point' for the calibration of thermometers? History of science has the answers.
2017-06-09
28. 16 Ibid., 37. 17 Ibid., 136. 12 unsuccessful due to wind and tide issues which enabled two British ships to elude the slow vessel.18...question of air supply was at one time one of the most difficult problems to solve on paper with which early experimenters with submarines had to contend...recently introduced the constant pressure engine. This engine was the basis for the gas turbine , and his design of constant pressure is now referred to
Concentration Dependent Physical Properties of Ge1-xSnx Solid Solution
NASA Astrophysics Data System (ADS)
Jivani, A. R.; Jani, A. R.
2011-12-01
Our own proposed potential is used to investigate few physical properties like total energy, bulk modulus, pressure derivative of bulk modulus, elastic constants, pressure derivative of elastic constants, Poisson's ratio and Young's modulus of Ge1-xSnx solid solution with x is atomic concentration of α-Sn. The potential combines linear plus quadratic types of electron-ion interaction. First time screening function proposed by Sarkar et al is used to investigate the properties of the Ge-Sn solid solution system.
Steam tables for pure water as an ActiveX component in Visual Basic 6.0
NASA Astrophysics Data System (ADS)
Verma, Mahendra P.
2003-11-01
The IAPWS-95 formulation for the thermodynamic properties of pure water was implemented as an ActiveX component ( SteamTables) in Visual Basic 6.0. For input parameters as temperature ( T=190-2000 K) and pressure ( P=3.23×10 -8-10,000 MPa) the program SteamTables calculates the following properties: volume ( V), density ( D), compressibility factor ( Z0), internal energy ( U), enthalpy ( H), Gibbs free energy ( G), Helmholtz free energy ( A), entropy ( S), heat capacity at constant pressure ( Cp), heat capacity at constant volume ( Cv), coefficient of thermal expansion ( CTE), isothermal compressibility ( Ziso), velocity of sound ( VelS), partial derivative of P with T at constant V (d Pd T), partial derivative of T with V at constant P (d Td V), partial derivative of V with P at constant T (d Vd P), Joule-Thomson coefficient ( JTC), isothermal throttling coefficient ( IJTC), viscosity ( Vis), thermal conductivity ( ThrmCond), surface tension ( SurfTen), Prandtl number ( PrdNum) and dielectric constant ( DielCons) for the liquid and vapor phases of pure water. It also calculates T as a function of P (or P as a function of T) along the sublimation, saturation and critical isochor curves, depending on the values of P (or T). The SteamTables can be incorporated in a program in any computer language, which supports object link embedding (OLE) in the Windows environment. An application of SteamTables is illustrated in a program in Visual Basic 6.0 to tabulate the values of the thermodynamic properties of water and vapor. Similarly, four functions, Temperature(Press), Pressure(Temp), State(Temp, Press) and WtrStmTbls(Temp, Press, Nphs, Nprop), where Temp, Press, Nphs and Nprop are temperature, pressure, phase number and property number, respectively, are written in Visual Basic for Applications (VBA) to use the SteamTables in a workbook in MS-Excel.
Development of a High Efficiency Compressor/Expander for an Air Cycle Air Conditioning System.
1982-11-15
bearing, lb PHUB - Hub pressure (initial guess), psia RLG - Rotor length 1 ’B-2 RPM - Rotational speed, RPM R - Gas constant, lb -ft/lb - R CP - Specific...Compressor discharge port pressure ratio (PCD/PC2).:- CDP - Compressor pressure change, PCD-PCl PHUB - Pressure in compressor hub (acting on base of vanes
Yao, Qian; Cao, Xiao-Mei; Zong, Wen-Gang; Sun, Xiao-Hui; Li, Ze-Rong; Li, Xiang-Yuan
2018-05-31
The isodesmic reaction method is applied to calculate the potential energy surface (PES) along the reaction coordinates and the rate constants of the barrierless reactions for unimolecular dissociation reactions of alkanes to form two alkyl radicals and their reverse recombination reactions. The reaction class is divided into 10 subclasses depending upon the type of carbon atoms in the reaction centers. A correction scheme based on isodesmic reaction theory is proposed to correct the PESs at UB3LYP/6-31+G(d,p) level. To validate the accuracy of this scheme, a comparison of the PESs at B3LYP level and the corrected PESs with the PESs at CASPT2/aug-cc-pVTZ level is performed for 13 representative reactions, and it is found that the deviations of the PESs at B3LYP level are up to 35.18 kcal/mol and are reduced to within 2 kcal/mol after correction, indicating that the PESs for barrierless reactions in a subclass can be calculated meaningfully accurately at a low level of ab initio method using our correction scheme. High-pressure limit rate constants and pressure dependent rate constants of these reactions are calculated based on their corrected PESs and the results show the pressure dependence of the rate constants cannot be ignored, especially at high temperatures. Furthermore, the impact of molecular size on the pressure-dependent rate constants of decomposition reactions of alkanes and their reverse reactions has been studied. The present work provides an effective method to generate meaningfully accurate PESs for large molecular system.
NASA Astrophysics Data System (ADS)
Teitelbaum, Heshel; Caridade, Pedro J. S. B.; Varandas, António J. C.
2004-06-01
Classical trajectory calculations using the MERCURY/VENUS code have been carried out on the H+O2 reactive system using the DMBE-IV potential energy surface. The vibrational quantum number and the temperature were selected over the ranges v=0 to 15, and T=300 to 10 000 K, respectively. All other variables were averaged. Rate constants were determined for the energy transfer process, H+O2(v)-->H+O2(v''), for the bimolecular exchange process, H+O2(v)-->OH(v')+O, and for the dissociative process, H+O2(v)-->H+O+O. The dissociative process appears to be a mere extension of the process of transferring large amounts of energy. State-to-state rate constants are given for the exchange reaction, and they are in reasonable agreement with previous results, while the energy transfer and dissociative rate constants have never been reported previously. The lifetime distributions of the HO2 complex, calculated as a function of v and temperature, were used as a basis for determining the relative contributions of various vibrational states of O2 to the thermal rate coefficients for recombination at various pressures. This novel approach, based on the complex's ability to survive until it collides in a secondary process with an inert gas, is used here for the first time. Complete falloff curves for the recombination of H+O2 are also calculated over a wide range of temperatures and pressures. The combination of the two separate studies results in pressure- and temperature-dependent rate constants for H+O2(v)(+Ar)⇄HO2(+Ar). It is found that, unlike the exchange reaction, vibrational and rotational-translational energy are liabilities in promoting recombination.
Wege, H A; Holgado-Terriza, J A; Cabrerizo-Vílchez, M A
2002-05-15
A new constant pressure pendant-drop penetration surface balance has been developed combining a pendant-drop surface balance, a rapid-subphase-exchange technique, and a fuzzy logic control algorithm. Beside the determination of insoluble monolayer compression-expansion isotherms, it allows performance of noninvasive kinetic studies of the adsorption of surfactants added to the new subphase onto the free surface and of the adsorption/penetration/reaction of the former onto/into/with surface layers, respectively. The interfacial pressure pi is a fundamental parameter in these studies: by working at constant pi one controls the height of the energy barrier to adsorption/penetration and can select different regimes and steps of the adsorption/penetration process. In our device a solution drop is formed at the tip of a coaxial double capillary, connected to a double microinjector. Drop profiles are extracted from digital drop micrographs and fitted to the equation of capillarity, yielding pi, the drop volume V, and the interfacial area A. pi is varied changing V (and hence A) with the microinjector. Control is based on a case-adaptable modulated fuzzy-logic PID algorithm able to maintain constant pi (or A) under a wide range of experimental conditions. The drop subphase liquid can be exchanged quantitatively by the coaxial capillaries. The adsorption/penetration/reaction kinetics at constant pi are then studied monitoring A(t), i.e., determining the relative area change necessary at each instant to compensate the pressure variation due to the interaction of the surfactant in the subsurface with the surface layer. A fully Windows-integrated program manages the whole setup. Examples of experimental protein adsorption and monolayer penetration kinetics are presented.
NASA Technical Reports Server (NTRS)
Scialdone, J. J.
1983-01-01
Methods to prevent the ingestion of external contaminants into the instrument and to limit the effect of the self-generated contaminants during ground, launch, orbiting and landing phases of flight were investigated. It is proposed that a positive pressure and purging flow of clean gas inside the instrument be maintained while on the ground, during launch, and for a period of time in orbit. The pressure to be maintained and the required purging flow are examined in terms of the effectiveness in preventing gaseous and particulate contaminants ingestion and the abatement of the self-generated contaminants. Considerations have been given to the venting requirements for the structural integrity of the instrument during launch, the limitations on the volume and the pressure of the purging gas to be carried along in orbit, and the required venting area is established based on the internal volume of the instrument, the allowable pressure differential, and the rate of external pressure change during launch.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Haiyan; Wang, Lijuan; Li, Kuo
Transformation between different types of carbon–carbon bonding in carbides often results in a dramatic change of physical and chemical properties. Under external pressure, unsaturated carbon atoms form new covalent bonds regardless of the electrostatic repulsion. It was predicted that calcium acetylide (also known as calcium carbide, CaC2) polymerizes to form calcium polyacetylide, calcium polyacenide and calcium graphenide under high pressure. In this work, the phase transitions of CaC2 under external pressure were systematically investigated, and the amorphous phase was studied in detail for the first time. Polycarbide anions like C 6 6- are identified with gas chromatography-mass spectrometry and severalmore » other techniques, which evidences the pressure induced polymerization of the acetylide anions and suggests the existence of the polyacenide fragment. Additionally, the process of polymerization is accompanied with a 107 fold enhancement of the electrical conductivity. The polymerization of acetylide anions demonstrates that high pressure compression is a viable route to synthesize novel metal polycarbides and materials with extended carbon networks, while shedding light on the synthesis of more complicated metal organics.« less
Irrigation Sprinklers Notice of Intent
High-efficiency irrigation sprinklers aim to deliver water more evenly to the landscape than traditional sprinklers and/or regulate outlet pressure to ensure a constant flow rate over a range of supply pressures.
Viscous interaction of flow redevelopment after flow reattachment with supersonic external streams
NASA Technical Reports Server (NTRS)
Chow, W. L.; Spring, D. J.
1975-01-01
A flow model has been developed to study the flow development after reattachment with supersonic external streams. Special attention is given to the pressure difference across the viscous layer, and it is suggested that such a flow redevelopment can be treated as a relaxation of this pressure difference. Upon correlating the pressure difference with a slope parameter of the velocity profile, the system of equations governing the flow would produce a saddle point singularity corresponding to the fully rehabilitated asymptotic flow condition. A method of calculation for this flowfield, in conjunction with the matching of the upstream flow, has been derived and is discussed. Samples of calculations are also presented. Reasonably good agreement with experimental data has also been observed.
Gritti, Fabrice; Gilar, Martin; Jarrell, Joseph A
2016-04-29
A cylindrical vacuum chamber (inner diameter 5 cm) housing a narrow-bore 2.1 mm×100 mm column packed with 1.8 μm HSS-T3 fully porous particles was built in order to isolate thermally the chromatographic column from the external air environment. Consistent with statistical physics and the mean free path of air molecules, the experimental results show that natural air convection and conduction are fully eliminated for housing air pressures smaller than 10(-4) Torr. Heat radiation is minimized by wrapping up the column with low-emissivity aluminum-tape (emissivity coefficient ϵ=0.03 vs. 0.28 for polished stainless steel 316). Overall, the heat flux at the column wall is reduced by 96% with respect to standard still-air ovens. From a practical viewpoint, the efficiency of the column run at a flow rate of 0.6 mL/min at a constant 13,000 psi pressure drop (the viscous heat power is around 9 W/m) is improved by up to 35% irrespective of the analyte retention. Models of heat and mass transfer reveal that (1) the amplitude of the radial temperature gradient is significantly reduced from 0.30 to 0.01 K and (2) the observed improvement in resolution power stems from a more uniform distribution of the flow velocity across the column diameter. The eddy dispersion term in the van Deemter equation is reduced by 0.8±0.1 reduced plate height unit, a significant gain in column performance. Copyright © 2016 Elsevier B.V. All rights reserved.