Science.gov

Sample records for contact sorptive tape

  1. Quantitative determination of some volatile suspected allergens in cosmetic creams spread on skin by direct contact sorptive tape extraction-gas chromatography-mass spectrometry.

    PubMed

    Sgorbini, B; Ruosi, M R; Cordero, C; Liberto, E; Rubiolo, P; Bicchi, C

    2010-04-16

    This study describes a method based on direct contact sorptive tape extraction followed by on-line thermal desorption gas chromatography-mass spectrometry (DC-STE-GC-MS) to detect and quantify a group of suspected volatile allergens on the European Union (E.U.) list and a related compound on the skin (the stratum corneum) of volunteers treated with a cream of known composition fortified with the reference allergens. The following compounds were tested: citronellol, Z-citral (neral), geraniol, cinnamaldehyde, anisyl alcohol, cinnamyl alcohol, eugenol, methyleugenol, coumarin, isoeugenol, alpha-isomethylionone, 2-(4-tert-butylbenzyl)propionaldehyde (lilial), alpha-amylcinnamaldehyde, alpha-hexylcinnamaldehyde. Sorptive tape extraction (STE) is a sorption-based sampling technique in which a flexible polydimethylsiloxane (PDMS) tape is used to recover analytes by direct contact with the surface of a solid matrix or from the headspace in equilibrium with it. The reliability of the method was confirmed by: (i) allergen recoveries varying from 52.3% for lilial to 95.7% for neral, (ii) linearity in the range 10-150ppm, with regression coefficient R(2) always above 0.97, (iii) repeatability of each analyte, RSD% never exceeding 10%, (iv) intermediate precision, always below 15%, and (v) LOD and LOQ in the ppb range, therefore fully compatible with E.U. prescriptions (ppm). Other parameters such as substantivity analyte, approximate permeation through skin and influence of different nature of stratum corneum on recovery were also investigated. The method was also successfully applied to five commercially available creams declared to contain some of the allergens in question spread on the skin of the same volunteers. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Direct Contact - Sorptive Tape Extraction coupled with Gas Chromatography - Mass Spectrometry to reveal volatile topographical dynamics of lima bean (Phaseolus lunatus L.) upon herbivory by Spodoptera littoralis Boisd.

    PubMed

    Boggia, Lorenzo; Sgorbini, Barbara; Bertea, Cinzia M; Cagliero, Cecilia; Bicchi, Carlo; Maffei, Massimo E; Rubiolo, Patrizia

    2015-04-12

    The dynamics of plant volatile (PV) emission, and the relationship between damaged area and biosynthesis of bioactive molecules in plant-insect interactions, remain open questions. Direct Contact-Sorptive Tape Extraction (DC-STE) is a sorption sampling technique employing non adhesive polydimethylsiloxane tapes, which are placed in direct contact with a biologically-active surface. DC-STE coupled to Gas Chromatography - Mass Spectrometry (GC-MS) is a non-destructive, high concentration-capacity sampling technique able to detect and allow identification of PVs involved in plant responses to biotic and abiotic stresses. Here we investigated the leaf topographical dynamics of herbivory-induced PV (HIPV) produced by Phaseolus lunatus L. (lima bean) in response to herbivory by larvae of the Mediterranean climbing cutworm (Spodoptera littoralis Boisd.) and mechanical wounding by DC-STE-GC-MS. Time-course experiments on herbivory wounding caused by larvae (HW), mechanical damage by a pattern wheel (MD), and MD combined with the larvae oral secretions (OS) showed that green leaf volatiles (GLVs) [(E)-2-hexenal, (Z)-3-hexen-1-ol, 1-octen-3-ol, (Z)-3-hexenyl acetate, (Z)-3-hexenyl butyrate] were associated with both MD and HW, whereas monoterpenoids [(E)-β-ocimene], sesquiterpenoids [(E)-nerolidol] and homoterpenes (DMNT and TMTT) were specifically associated with HW. Up-regulation of genes coding for HIPV-related enzymes (Farnesyl Pyrophosphate Synthase, Lipoxygenase, Ocimene Synthase and Terpene Synthase 2) was consistent with HIPV results. GLVs and sesquiterpenoids were produced locally and found to influence their own gene expression in distant tissues, whereas (E)-β-ocimene, TMTT, and DMNT gene expression was limited to wounded areas. DC-STE-GC-MS was found to be a reliable method for the topographical evaluation of plant responses to biotic and abiotic stresses, by revealing the differential distribution of different classes of HIPVs. The main advantages of this

  3. Direct Contact Sorptive Extraction: A Robust Method for Sampling Plant Volatiles in the Field.

    PubMed

    Kfoury, Nicole; Scott, Eric; Orians, Colin; Robbat, Albert

    2017-09-27

    Plants produce volatile organic compounds (VOCs) with diverse structures and functions, which change in response to environmental stimuli and have important consequences for interactions with other organisms. To understand these changes, in situ sampling is necessary. In contrast to dynamic headspace (DHS), which is the most often employed method, direct contact sampling employing a magnetic stir bar held in place by a magnet eliminates artifacts produced by enclosing plant materials in glass or plastic chambers. Direct-contact sorptive extraction (DCSE) using polydimethylsiloxane coated stir bars (Twisters) coated stir bars is more sensitive than DHS, captures a wider range of compounds, minimizes VOC collection from neighboring plants, and distinguishes the effects of herbivory in controlled and field conditions. Because DCSE is relatively inexpensive and simple to employ, scalability of field trials can be expanded concomitant with increased sample replication. The sensitivity of DCSE combined with the spectral deconvolution data analysis software makes the two ideal for comprehensive, in situ profiling of plant volatiles.

  4. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  6. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    PubMed

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  7. Friction and morphology of magnetic tapes in sliding contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Bhushan, B.

    1984-01-01

    Friction and morphological studies were conducted with magnetic tapes containing a Ni-Zn ferrite hemispherical pin in laboratory air at a relative humidity of 40 percent and at 23 C. The results indicate that the binder plays a significant role in the friction properties, morphology, and microstructure of the tape. Comparisons were made with four binders: nitrocellulose; poly (vinyledene) chloride; cellulose acetate; and hydroxyl-terminated, low molecular weight polyester added to the base polymer, polyester-polyurethane. The coefficient of friction was lowest for the tape with the nitrocellulose binder and increased in the order hydroxylterminated, low molecular weight polyester resin; poly (vinyledene) chloride; and cellulose acetate. The degree of enclosure of the oxide particles by the binder was highest for hydroxyl-terminated, low molecular weight polyester and decreased in the order cellulose acetate, poly (vinyledene) chloride, and nitrocellulose. The nature of deformation of the tape was a factor in controlling friction. The coefficient of friction under elastic contact conditions was considerably lower than under conditions that produced plastic contacts.

  8. Abrasion and deformed layer formation of manganese-zinc ferrite in sliding contact with lapping tapes

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1986-01-01

    Wear experiments were conducted using replication electron microscopy and reflection electron diffraction to study abrasion and the deformed layers produced in single-crystal Mn-Zn ferrite simulated heads during contact with lapping tapes. The crystaline state of the head is changed drastically during the abrasion process. Crystalline states ranging from nearly amorphous to highly textured polycrystalline can be produced on the wear surface of a single-crystal Mn-Zn ferrite head. The total thickness of the deformed layer was approximately 0.8 microns. This thickness increased as the load and abrasive grit size increased. The anisotropic wear of the ferrite was found to be inversely proportional to the hardness of the wear surface. The wear was lower in the order 211 111 10 0110. The wear of the ferrite increased markedly with an increase in sliding velocity and abrasive grit size.

  9. Effects of wear on structure-sensitive magnetic properties of ceramic ferrite in contact with magnetic tape

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1985-01-01

    Wear experiments and electron microscopy and diffraction studies were conducted to examine the wear and deformed layers in single-crystal Mn-Zn (ceramic) ferrite magnetic head material in contact with magnetic tape and the effects of that contact on magnetic properties. The crystalline state of the single-crystal magnetic head was changed drastically during the sliding process. A nearly amorphous structure was produced on its wear surface. Deformation in the surficial layer of the magnetic head was a critical factor in readback signal loss above 2.5 dB. The signal output level was reduced as applied normal load was increased. Considerable plastic flow occurred on the magnetic tape surface with sliding, and the signal loss due to the tape wear was approximately 1 dB.

  10. Contact resistance between two REBCO tapes under load and load cycles

    NASA Astrophysics Data System (ADS)

    Lu, Jun; Goddard, Robert; Han, Ke; Hahn, Seungyong

    2017-04-01

    No-insulation (NI) REBCO magnets have many advantages. They are self-protecting, and therefore do not need quench detection and protection, which can be very challenging to implement in a high T c superconducting magnet. Moreover, by removing the insulation and allowing thinner copper stabilizers, NI REBCO magnets have significantly higher engineering current density and higher mechanical strength. On the other hand, NI REBCO magnets have the drawbacks of long magnet charging time and high field ramp loss. In principle, these drawbacks can be mitigated by managing the turn-to-turn contact resistivity (R c). Evidently, the first step toward managing R c is to establish a reliable method of accurate R c measurement. In this paper, we present experimental R c measurements for REBCO tapes as a function of mechanical load up to 144 MPa and load cycles up to 14. We find that R c is in the range of 26-100 μΩ·cm2, and that it decreases with increasing pressure, and gradually increases with the number of load cycles. The results are discussed in the framework of Holm’s electric contact theory.

  11. Friction and Morphology of Magnetic Tapes in Sliding Contact with Nickel-Zinc Ferrite.

    DTIC Science & Technology

    1984-01-01

    microstructure of the tape. Comparisons were made with four binders: nitrocellulose; poly(vinyledene) chloride; cellulose acetate ; and hydroxyl-terminated, low...nitrocellulose binder and increased in the order hydroxyl-terminated, low-molecular-weight polyester resin; poly (vinyledene) chloride; and cellulose acetate . The...order cellulose acetate , poly (vinyledene) chloride, and nitrocellulose. The nature of deformation of the tape was a factor in controlling friction. The

  12. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  13. Humidity effects on adhesion of nickel-zinc ferrite in elastic contact with magnetic tape and itself

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Kusaka, T.; Maeda, C.

    1985-01-01

    The effects of humidity on the adhesion of Ni-Zn ferrite and magnetic tape in elastic contact with a Ni-Zn ferrite hemispherical pin in moist nitrogen were studied. Adhesion was independent of normal load in dry, humid, and saturated nitrogen. Ferrites adhere to ferrites in a saturated atmosphere primarily from the surface tension effects of a thin film of water adsorbed on the ferrite surfaces. The surface tension of the water film calculated from the adhesion results was 48 times 0.00001 to 56 times 0.00001 N/cm; the accepted value for water is 72.7 x 0.00001 N/cm. The adhesion of ferrite-ferrite contacts increased gradually with increases in relative humidity to 80 percent, but rose rapidly above 80 percent. The adhesion at saturation was 30 times or more greater than that below 80 percent relative humidity. Although the adhesion of magnetic tape - ferrite contacts remained low below 40 percent relative humidity and the effect of humidity was small, the adhesion increased considerably with increasing relative humidity above 40 percent. The changes in adhesion of elastic contacts were reversible on humidifying and dehumidifying.

  14. Modeling the evolution of thermal contact resistance between two thermoplastic pre-impregnated tapes considering the real surface

    NASA Astrophysics Data System (ADS)

    Leon, Angel; Barasinski, Anais; Chinesta, Francisco

    2016-10-01

    In this work, we address the modeling of in-situ consolidation considering the real description of the surfaces between two pre-impregnated (pre-pregs) tapes. A walevet-based description is used to represent the real surface between pre-pregs, using the Haar wavelet. Since the surface is well described, in order to carry out the compression of both surfaces for consolidating, the flow model during the compression of each asperity is discussed: lubrication hypotheses considering partial wall slip condition at the asperities interfaces are compared to the fully numerical solution of Newtonian and non-Newtonian flows. Once the surface deformation is properly described, the thermal contact resistance is obtained by solving the thermal problem during the compression process of both surfaces. In order to make possible the fully numerical solution of all scales involved in the surface representation (due to its fractal nature), both, the Stokes and the thermal problems are solved by using the Proper Generalized Decomposition (PGD).

  15. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  16. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  17. VLBA: Formatter to Tape

    NASA Astrophysics Data System (ADS)

    Rogers, A. E. E. R.

    Introduction; Why Magnetic Tape?; VLBI Recording Systems; The VLBA Data Format; Longitudinal Format; Transverse Track Format; Data and Non-Data Replacement; Track Width and Track Structure; The VLBA Formatter; Switch Board; Header Control Board; Transport Driver Board; Timing and Control Board; DataBuffer Board; Analysis Board; Magnetic Recording Fundamentals; Recording Losses; Wavelength Response; Head-to-Tape Contact and Tribology; The VLBA Recorder; The Tape Transport; The Headstack; The Headstack Positioner; Control Electronics; Signal Electronics and Eye Pattern; Characteristics and Limitations; Error Rate Versus Bit Density; Tape Thickness Interchange; Head Flying; Overwrite; Tracking Errors; Headlife and Humidity; Thin Tape and Edge Damage by Frictional Heating; Tape Reel and Shipping Canister; Future VLBI Recording Systems; Expansion Paths for the VLBA Formatter; Recorder Improvements; Thinner Tape; Higher Data Rates; Next Generation of Heads; Mark IV; Summary and Conclusions

  18. Review of Allergic and Photoallergic Contact Dermatitis from an Ingredient in a Medicament Vehicle Consisting of a Compress, Poultice, Plaster, and Tape

    PubMed Central

    Oiso, Naoki; Kawada, Akira

    2011-01-01

    The topical application of a medicament vehicle consisting of a compress, poultice, plaster, and tape containing a nonsteroidal anti-inflammatory drug or methyl salicylate is prevalent in Japan. The method is effective for conveying ingredients to the muscles via the skin for the relief of muscular pain. However, an ingredient in the occlusive vehicle can cause allergic and photoallergic contact dermatitis. We summarize cases reported over the past decade and discuss the current strategy for diminishing the risk of allergic and photoallergic contact dermatitis. PMID:21603165

  19. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Thomas, R. D. (Inventor)

    1973-01-01

    A thermocouple which may be rolled as a tape until needed and a method of making it are described. Thermoelectrically different metals are applied to a strip of electrically nonconductive material in longitudinally overlapping relationship. Apertures may be provided along the tape in overlapping region at predetermined intervals. An adhesive material is applied to the side of the tape opposite the thermoelectric metals either before or after the thermoelectric metals are deposited. The tape may be cut or torn to form a thermocouple device which is ready for application to a body whose temperature is to be monitored or measured.

  20. Millimeter-scale contact printing of aqueous solutions using a stamp made out of paper and tape.

    PubMed

    Cheng, Chao-Min; Mazzeo, Aaron D; Gong, Jinlong; Martinez, Andres W; Phillips, Scott T; Jain, Nina; Whitesides, George M

    2010-12-07

    This communication describes a simple method for printing aqueous solutions with millimeter-scale patterns on a variety of substrates using an easily fabricated, paper-based microfluidic device (a paper-based "stamp") as a contact printing device. The device is made from inexpensive materials, and it is easily assembled by hand; this method is thus accessible to a wide range of laboratories and budgets. A single device was used to print over 2500 spots in less than three minutes at a density of 16 spots per square centimetre. This method provides a new tool to pattern biochemicals-reagents, antigens, proteins, and DNA-on planar substrates. The accuracy of the volume of fluid delivered in simple paper-to-paper printing is low, and although the pattern transfer is rapid, it is better suited for qualitative than accurate, quantitative work. By patterning the paper to which the transfer occurs using wax printing or an equivalent technique, accuracy increases substantially.

  1. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  2. Stir bar sorptive extraction for trace analysis.

    PubMed

    David, Frank; Sandra, Pat

    2007-06-08

    Stir bar sorptive extraction (SBSE) was introduced in 1999 as a solventless sample preparation method for the extraction and enrichment of organic compounds from aqueous matrices. The method is based on sorptive extraction, whereby the solutes are extracted into a polymer coating on a magnetic stirring rod. The extraction is controlled by the partitioning coefficient of the solutes between the polymer coating and the sample matrix and by the phase ratio between the polymer coating and the sample volume. For a polydimethylsiloxane coating and aqueous samples, this partitioning coefficient resembles the octanol-water partitioning coefficient. In comparison to solid phase micro-extraction, a larger amount of sorptive extraction phase is used and consequently extremely high sensitivities can be obtained as illustrated by several successful applications in trace analysis in environmental, food and biomedical fields. Initially SBSE was mostly used for the extraction of compounds from aqueous matrices. The technique has also been applied in headspace mode for liquid and solid samples and in passive air sampling mode. In this review article, the principles of stir bar sorptive extraction are described and an overview of SBSE applications is given.

  3. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  4. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Mazaris, G. A., Jr.; Thomas, R. D.

    1972-01-01

    Preformed, low cost, thin film thermocouples on adhesive tapes were fabricated. Metal strips of two dissimilar metals were laid on opposite edges of plastic substrate so that they overlap in center portion, forming thermocouple junction. Useful temperature range for polyimide films was 4 to 673 K.

  5. Sorptivity and liquid infiltration into dry soil

    NASA Astrophysics Data System (ADS)

    Culligan, Patricia J.; Ivanov, Vladimir; Germaine, John T.

    2005-10-01

    The sorptivity S quantifies the effect of capillarity on liquid movement in a porous material. For liquid infiltration into an initially dry material, S is a parameter that is contingent on both liquid and material properties as well as the maximum liquid content behind the infiltrating front, θm. Scaling analyses are used to derive a dimensionless, intrinsic sorptivity S∗ that is constant for different liquids, Miller-similar materials and different values of θm. The analyses confirm that S is dependent on β1/2, where β = cos ϕ is a measure of the wettability of the liquid. They also indicate a power law relationship between S and Se(av), the average liquid saturation behind the infiltrating front. Seventeen water and eleven Soltrol 220 horizontal infiltration experiments are reported in uniform, dry sand. Test results show that water is partially wetting in the sand. They also confirm that S∝Se(av)d, where d = 3.2 for the experimental conditions. The usefulness of a general, dimensionless Boltzmann variable is demonstrated to normalize infiltration profiles for the different liquids. An approximate method for sorptivity calculation is shown to provide an accurate estimate of S∗.

  6. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  7. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  8. Acoustics of multiscale sorptive porous materials

    NASA Astrophysics Data System (ADS)

    Venegas, R.; Boutin, C.; Umnova, O.

    2017-08-01

    This paper investigates sound propagation in multiscale rigid-frame porous materials that support mass transfer processes, such as sorption and different types of diffusion, in addition to the usual visco-thermo-inertial interactions. The two-scale asymptotic method of homogenization for periodic media is successively used to derive the macroscopic equations describing sound propagation through the material. This allowed us to conclude that the macroscopic mass balance is significantly modified by sorption, inter-scale (micro- to/from nanopore scales) mass diffusion, and inter-scale (pore to/from micro- and nanopore scales) pressure diffusion. This modification is accounted for by the dynamic compressibility of the effective saturating fluid that presents atypical properties that lead to slower speed of sound and higher sound attenuation, particularly at low frequencies. In contrast, it is shown that the physical processes occurring at the micro-nano-scale do not affect the macroscopic fluid flow through the material. The developed theory is exemplified by introducing an analytical model for multiscale sorptive granular materials, which is experimentally validated by comparing its predictions with acoustic measurements on granular activated carbons. Furthermore, we provide empirical evidence supporting an alternative method for measuring sorption and mass diffusion properties of multiscale sorptive materials using sound waves.

  9. Dual-phase twisters: a new approach to headspace sorptive extraction and stir bar sorptive extraction.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara; David, Frank; Sandra, Pat

    2005-11-11

    The fields of applicability of headspace sorptive extraction (HSSE) and stir bar sorptive extraction (SBSE) using polydimethylsiloxane (PDMS) as sorbent have been intensively discussed and widely described. One of the limits of sorptive extraction is that PDMS (i.e. an apolar phase) is the only polymer currently in use making it difficult to recover polar analytes from complex or multi-ingredient matrices and those with very volatile components (C1-C4 analytes). Dual-phase twisters are here introduced as new tools for HSSE and SBSE to overcome the above limits. Dual-phase twisters combine the concentration capabilities of two or more sampling materials operating in different ways (in this case sorption and adsorption). The new twisters consist of a short PDMS tube the ends of which are closed with two magnetic stoppers, thus creating an inner cavity that can be packed with different types of adsorbents like activated carbons. The concentration capability of dual-phase twisters was evaluated by using them for the HSSE and SBSE sampling of a number of matrices in the vegetable, food and environmental fields. The contributions made by different carbons to recovery, repeatability and intermediate precision were also investigated.

  10. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  11. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  12. CREATIVE TEACHING WITH TAPE.

    ERIC Educational Resources Information Center

    Minnesota Mining and Mfg. Co., St. Paul. Revere-Mincom Div.

    SOME CLASSROOM APPLICATIONS OF THE TAPE RECORDER ARE DISCUSSED, WITH SECTIONS ON THE CARE, USE, AND SELECTION OF TAPE RECORDING EQUIPMENT ACCESSORIES. THIS DOCUMENT IS AVAILABLE FROM WOLLENSAK-3M COMPANY ATTENTION--CREATIVE TEACHING WITH TAPE, 2501 HUDSON ROAD, ST. PAUL, MINNESOTA 55119. (MS)

  13. On the recovery of fibres by tape lifts, tape scanning, and manual isolation.

    PubMed

    Schotman, Tom G; van der Weerd, Jaap

    2015-12-01

    The recovery of fibre traces via tape lifting, tape scanning and manual isolation is investigated. The recovery efficiency of taping was determined using different tapes, donor textiles, and receptor textiles. It was determined that tape lifts generally recover over 90% of extraneous fibres that had been transferred by direct contact with a donor textile. The recovery via tape scanning was evaluated by the preparation of a set of 15 tapes that contained a number of target fibres on a background of other fibres. The tapes presented varying difficulty and were investigated by trained fibre examiners. The examiners were asked to locate the target fibres and to provide their opinion on the difficulty of the search. As expected, the efficiency decreases for more difficult searches. It was determined that the efficiency of the search was influenced by the microscopic illumination modes used by the examiner. A final experiment investigated the recovery by manual isolation of fibres from non-textile items. It was determined that all fibres from tie cables and knives were recovered, except in those cases where the recipient item contained many fibres. In addition, the examiners correctly sampled each of three fibre populations present on a sample of duct tape. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  14. HEURISTIC OPTIMIZATION AND ALGORITHM TUNING APPLIED TO SORPTIVE BARRIER DESIGN

    EPA Science Inventory

    While heuristic optimization is applied in environmental applications, ad-hoc algorithm configuration is typical. We use a multi-layer sorptive barrier design problem as a benchmark for an algorithm-tuning procedure, as applied to three heuristics (genetic algorithms, simulated ...

  15. HEURISTIC OPTIMIZATION AND ALGORITHM TUNING APPLIED TO SORPTIVE BARRIER DESIGN

    EPA Science Inventory

    While heuristic optimization is applied in environmental applications, ad-hoc algorithm configuration is typical. We use a multi-layer sorptive barrier design problem as a benchmark for an algorithm-tuning procedure, as applied to three heuristics (genetic algorithms, simulated ...

  16. ERTS wideband tape recorder

    NASA Technical Reports Server (NTRS)

    Hayes, J. M.

    1973-01-01

    The ERTS video bandwith tape recorder uses a rotary head to run the tape in transverse mode; the head wheel gives a head-to-tape surface speed of nearly 5080 centimeter per second. The electronics unit handles 15 megabit per second rate with a bit-error rate of 0.00001. An operational unit onboard ERTS A returned images from the 85 to 90 percent of the earth that are not available in real time.

  17. GRIPPER DEVICE FOR TAPES

    DOEpatents

    Bellarts, H.J.

    1962-10-23

    The relationship of a two-part plug or dummy fuel element and a flat thin metallic tape that is releasably gripped edgewise by the plug is described. The plug and tape shift a column of fuel elements lengthwise in a reactor process tube, through a pull transmitted to the tape by an operator and a push of the plug against the column of fuel elements. (AEC)

  18. Magnetic Tape Care, Storage, and Error Recovery.

    ERIC Educational Resources Information Center

    Schenck, Thomas

    1984-01-01

    Explains format of data on magnetic tape and process of reading and writing data to tape, and discusses sources of tape errors (physically damaged tape, unclean tape, magnetic alteration of data on tape, unclean or defective tape drive); correcting and/or bypassing tape errors; and care, storage, and shipment of tapes. (EJS)

  19. Effects of taping on Achilles tendon protection and kendo performance.

    PubMed

    Tsai, Feng-Hua; Chu, I-Hua; Huang, Chun-Hao; Liang, Jing-Min; Wu, Jia-Hroung; Wu, Wen-Lan

    2017-03-02

    It has been reported that there is high rate of Achilles tendon injury among kendo athletes. For protection and support the area, kendo athletes habitually use taping during practice or games. To investigate the effect of various taping techniques on injury prevention and functional performance in kendo athletes. Case-control study. Laboratory. Fifteen University Kendo Team athletes with at least 2 years kendo experience. Athletes completed 5 stepping backwards and striking cycles under four taping conditions: No taping; Athletic taping of ankle joint (AT-Ankle); Athletic taping of Achilles tendon (AT-Achilles); and Kinesio-Tex taping of Achilles tendon (KT-Achilles). Jump distance, lower limb angular motion, left foot-ground contact time, Achilles tendon force (ATF), and soleus and medial gastrocnemius muscle activities. Lowest peak ATF was found in AT-Achilles during heel-down phase, statistically significantly different from KT-Achilles peak force. Significant decline of soleus muscle EMG amplitude was also found when compared to No taping, during heel-down phase and other conditions during pushing phase. Conversely, KT-Achilles showed significant decrease in foot-ground contact time compared with No taping and greater ankle range of motion than in AT-Ankle. To protect the Achilles tendon, AT-Achilles taping is recommended since it tends to decrease ATF. Conversely, to enhance athletes' performance, we recommend KT-Achilles taping to speed up kendo striking motion. However, the Achilles tendon must withstand greatest forces concurrently. This finding implies that AT-Achilles taping can protect the injured Achilles tendon and KT-Achilles taping can enhance performance on the kendo striking motion.

  20. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  1. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  2. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  3. Solar cell interconnection and packaging using tape carrier

    SciTech Connect

    Kim, N.P.; Stanbery, B.J.

    1991-06-04

    This paper describes an array of photovoltaic cells. It comprises: photovolatic cells having a ratio of mass to surface area of less than 60 milligrams/square centimeter; a dielectric tape having a carrier surface for supporting the photovoltaic cells; interconnect means including an electrical circuit for electrically interconnecting the photovoltaic cells, the interconnect means supported by the dielectric tape on the carrier surface, the electrical circuit including contact fingers; and means defining primary openings in the dielectric tape, a primary opening being associated with a contact finger and positioned such that the contact finger can be directed from below the carrier surface in the direction of the photovoltaic cells and electrically connected to a photovoltaic cell, a portion of both sides of the contact finger being substantially free of the dielectric tape. This patent also describes the array of the above claim, wherein the photovoltaic cells are tandem cells including an upper subcell and a lower subcell.

  4. Duct Tape Durability Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2004-04-01

    Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

  5. Relationship between liquid sorptivity and capillarity in concrete

    SciTech Connect

    Hanzic, L.; Ilic, R

    2003-09-01

    Neutron radiography (NR) was applied to study liquid transport processes in concrete. With this method, it is possible to monitor the liquid distribution inside specimens and to measure the height of the liquid front for liquids of high hydrogen content inside concrete. The experiment was performed with water and fuel oil for three different types of concrete. The results are compared with the sorptivity measured by the gravimetric method. It is shown that the ratio between the capillarity coefficient and sorptivity depends upon the combination of liquid and solid phases. For water, this value was found to be 5.5{+-}0.6, 5.8{+-}0.6 and 7.1{+-}0.7 in concrete without additives, concrete with an air-entraining agent and concrete with a plasticizer, respectively. For fuel oil, the value is about 50% higher than that for water.

  6. Towards a 1000 tracks digital tape recorder

    NASA Astrophysics Data System (ADS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  7. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  8. Carbon Nanotube-Based Synthetic Gecko Tapes

    NASA Astrophysics Data System (ADS)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  9. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  10. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  11. Tape Dump and Restore.

    DTIC Science & Technology

    1980-08-28

    VM/ CMS as provided at Virginia Tech and to make it possible to transfer files from this system to other computer systems , possibly machines using the...Technical Memorandum No. 80-5 DTI(-C August 28, 1980 DEC T.77w S DEC23 1980 F ABSTRACT A set of three programs to write CMS disk files on magnetic...tape in a variety of formats suitable for reading on a variety of computing systems and for restoring these tape files to disk within the restrictions

  12. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  13. Modeling of the viscoelastic mechano-sorptive behavior in wood

    NASA Astrophysics Data System (ADS)

    Dubois, Frédéric; Husson, Jean-Marie; Sauvat, Nicolas; Manfoumbi, Nicaise

    2012-11-01

    This paper focuses on the modeling of linearly viscoelastic, mechano-sorptive behavior and its effects during moisture content changes in timber. A generalized Kelvin-Voigt model integrating specific hygro-lock springs is developed and associated, in series, with a shrinkage-swelling element. The coupling between moisture content state and mechanical state implies an evolution in rheological parameters. This alternative approach leads to incorporating strain blockings during the drying period as well as memory effects during wetting phases after unloading. An incremental formulation is also established using a finite-element software, and, moreover, an experimental validation from tensile creep-recovery tests is presented.

  14. Adhesive Tape and Intravascular-Catheter-Associated Infections

    PubMed Central

    Redelmeier, Donald A; Livesley, Nigel J

    1999-01-01

    Adhesive tape is placed in close contact with intravascular catheters for extended periods and could theoretically contribute to local infections. We found that 74% of specimens of tape collected in one hospital were colonized by pathogenic bacteria. However, only 5% of specimens had significant growth from an inner layer obtained by discarding the outside layer from each roll. We suggest that adhesive tape is a potential source of pathogenic bacteria and that discarding the outer layer from a partially used roll might be a simple method for reducing the risk of infection to patients. PMID:10354258

  15. Determination of crystal violet in water by direct solid phase spectrophotometry after rotating disk sorptive extraction.

    PubMed

    Manzo, Valentina; Navarro, Orielle; Honda, Luis; Sánchez, Karen; Inés Toral, M; Richter, Pablo

    2013-03-15

    The microextraction of crystal violet (CV) from water samples into polydimethylsiloxane (PDMS) using the rotating disk sorptive extraction (RDSE) technique was performed. The extracting device was a small Teflon disk that had an embedded miniature magnetic stirring bar and a PDMS (560 μL) film attached to one side of the disk using double-sided tape. The extraction involves a preconcentration of CV into the PDMS, where the analyte is then directly quantified using solid phase spectrophotometry at 600 nm. Different chemical and extraction device-related variables were studied to achieve the best sensitivity for the determination. The optimum extraction was performed at pH 14 because under this condition, CV is transformed to the neutral and colorless species carbinol, which can be quantitatively transferred to the PDMS phase. Although the colorless species is the chemical form extracted in the PDMS, an intense violet coloration appeared in the phase because the -OH bond in the carbinol molecule is weakened through the formation of hydrogen bonds with the oxygen atoms of the PDMS, allowing the resonance between the three benzene rings to compensate for the charge deficit on the central carbon atom of the molecule. The accuracy and precision of the method were evaluated in river water samples spiked with 10 and 30 μg L(-1) of CV, yielding a relative standard deviation of 6.2% and 8.4% and a recovery of 98.4% and 99.4%, respectively. The method detection limit was 1.8 μg L(-1) and the limit of quantification was 5.4 μg L(-1), which can be decreased if the sample volume is increased.

  16. Supplemental TV Taped Problems.

    ERIC Educational Resources Information Center

    Squires, Robert G.; Frank, David V.

    1983-01-01

    Videotapes were developed as supplemental material for a course in chemical engineering thermodynamics. Describes the course, videotapes produced (includes list by topics as related to course content), and effectiveness of the tapes. Although no significant improvement in test performance was noted, students indicated they learned material faster…

  17. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  18. MAG -- Access to magnetic tapes

    NASA Astrophysics Data System (ADS)

    Allan, P. M.; Chipperfield, A. J.

    The MAG subroutine library allows a programmer to write portable programs which access data stored on magnetic tapes. By using the MAG routines, a program can read and write tapes, position the tape (both in absolute terms and relative to the current position) and can control the allocation of the tape drive and the physical mounting of the tape on systems which provide that facility. The library is currently supported for Sun Sparcstations running Solaris and for DEC Alphas running OSF/1. Historically it has been supported for DEC Ultrix and for SunOS and may still work for them. The library is also available for VAX/VMS systems.

  19. Tamper tape seals

    SciTech Connect

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R&D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique {open_quotes}fingerprint{close_quotes} characteristics that can be accessed as desired.

  20. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  1. Application of stir bar sorptive extraction for wine analysis.

    PubMed

    Hayasaka, Yoji; MacNamara, Kevin; Baldock, Gayle A; Taylor, Randell L; Pollnitz, Alan P

    2003-04-01

    Stir bar sorptive extraction (SBSE) coupled with gas chromatography/mass spectrometry (GC/MS) was used to analyse wine samples for three applications: flavour and compositional analysis; 2,4,6-trichloroanisole (TCA), a common off-aroma in wine; and agrochemicals. SBSE was found to be orders of magnitude more sensitive than modern conventional methodology, allowing for lower detection and quantitation levels, and improved confirmation of identity; SBSE often gave better signal to noise in scan mode than other methods in selective ion monitoring (SIM) mode. With the help of their characteristic mass spectra all agrochemicals could be identified unambiguously at concentrations of 10 microg L(-1) in wine and a further 100 constituents were detected in a Cabernet Sauvignon sample. Thus it is now possible to analyse complex samples such as wine by scan mode, with better confirmation of identity, and without sacrificing sensitivity, where previously SIM methodology had to be used.

  2. Characterisation, quantity and sorptive properties of microplastics extracted from cosmetics.

    PubMed

    Napper, Imogen E; Bakir, Adil; Rowland, Steven J; Thompson, Richard C

    2015-10-15

    Cosmetic products, such as facial scrubs, have been identified as potentially important primary sources of microplastics to the marine environment. This study characterises, quantifies and then investigates the sorptive properties of plastic microbeads that are used as exfoliants in cosmetics. Polyethylene microbeads were extracted from several products, and shown to have a wide size range (mean diameters between 164 and 327 μm). We estimated that between 4594 and 94,500 microbeads could be released in a single use. To examine the potential for microbeads to accumulate and transport chemicals they were exposed to a binary mixture of (3)H-phenanthrene and (14)C-DDT in seawater. The potential for transport of sorbed chemicals by microbeads was broadly similar to that of polythene (PE) particles used in previous sorption studies. In conclusion, cosmetic exfoliants are a potentially important, yet preventable source of microplastic contamination in the marine environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Stir bar sorptive extraction: recent applications, limitations and future trends.

    PubMed

    Camino-Sánchez, F J; Rodríguez-Gómez, R; Zafra-Gómez, A; Santos-Fandila, A; Vílchez, J L

    2014-12-01

    Stir bar sorptive extraction (SBSE) has generated growing interest due to its high effectiveness for the extraction of non-polar and medium-polarity compounds from liquid samples or liquid extracts. In particular, in recent years, a large amount of new analytical applications of SBSE has been proposed for the extraction of natural compounds, pollutants and other organic compounds in foods, biological samples, environmental matrices and pharmaceutical products. The present review summarizes and discusses the theory behind SBSE and the most recent developments concerning its effectiveness. In addition, the main results of recent analytical approaches and their applications, published in the last three years, are described. The advantages, limitations and disadvantages of SBSE are described and an overview of future trends and novel extraction sorbents and supports is given.

  4. Interplay between sniffing and odorant sorptive properties in the rat

    PubMed Central

    Rojas-Líbano, Daniel; Kay, Leslie M.

    2012-01-01

    For decades it has been known that the olfactory sensory epithelium can act like a chromatograph, separating odorants based on their air-mucus sorptive properties (Mozell and Jagodowicz, 1973). It has been hypothesized that animals could take advantage of this property, modulating sniffing behavior to manipulate airflow and thereby direct odorant molecules to the portions of the olfactory epithelium where they are best detected (Schoenfeld and Cleland, 2005). We report here a test of this hypothesis in behaving rats, monitoring respiratory activity through diaphragm EMG, which allowed us to estimate nasal airflow. In our test rats had to detect either low-sorption (LS) or high-sorption (HS) monomolecular odorant targets from the same stimulus set of six binary odor mixtures. We found that it is more difficult for rats to detect LS than HS targets. Even though sniffing bouts are the same duration for each group (approximately 500 ms), sniffing longer and using more inhalations results in better performance for rats assigned to detect LS targets. LS-detecting rats also increase the duration of individual inhalations (81 msec for LS- vs. 69 msec for HS-detecting rats) and sniff at lower frequencies (7.8 Hz for LS- vs. 8.6 Hz for HS-detecting rats) when learning to sense the target. When LS-detecting rats do discriminate well, they do so with lower airflow, more sniffs and lower frequency sniffing than HS-detecting counterparts. These data show that rats adjust sniff strategies as a function of odorant sorptiveness and provide support for the chromatographic and zonation hypotheses. PMID:23115193

  5. Magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.; Jafferis, W.

    1980-01-01

    Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

  6. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  7. Pillows and Tape.

    PubMed

    Mand, Parandeep; Miller, Kevin M

    2010-03-09

    A 76-year-old man with a severe neck deformity resulting in a facedown posture presented with a visually significant cataract in his right eye. The patient had been scheduled for cataract surgery elsewhere, but the surgery was cancelled in the operating room when he could not be positioned beneath the operating microscope. The patient's surgery was safely and effectively performed by placing 25 to 30 pillows under his buttocks and legs and one pillow and a towel beneath his head and neck. The patient and pillows were taped to the operating table so that they would not move.

  8. Tape casting of magnesium oxide.

    SciTech Connect

    Ayala, Alicia; Corral, Erica L.; Loehman, Ronald E.; Bencoe, Denise Nora; Reiterer, Markus; Shah, Raja A.

    2008-02-01

    A tape casting procedure for fabricating ceramic magnesium oxide tapes has been developed as a method to produce flat sheets of sintered MgO that are thin and porous. Thickness of single layer tapes is in the range of 200-400 {micro}m with corresponding surface roughness values in the range of 10-20 {micro}m as measured by laser profilometry. Development of the tape casting technique required optimization of pretreatment for the starting magnesium oxide (MgO) powder as well as a detailed study of the casting slurry preparation and subsequent heat treatments for sintering and final tape flattening. Milling time of the ceramic powder, plasticizer, and binder mixture was identified as a primary factor affecting surface morphology of the tapes. In general, longer milling times resulted in green tapes with a noticeably smoother surface. This work demonstrates that meticulous control of the entire tape casting operation is necessary to obtain high-quality MgO tapes.

  9. Multifilamentary niobium tin superconductor tape

    NASA Technical Reports Server (NTRS)

    Brisbin, P. H.; Coles, W. D.

    1975-01-01

    In the method proposed for fabricating multifilamentary Nb3Sn tape, filamentary superconducting paths are produced in standard commercial superconductor tape by chemical milling of separator slots through the Nb3Sn layer. The multifilament configuration features a matrix of ten 1.2 mm wide parallel helical superconducting paths along the length of the tape. The paths are spaced 0.4 mm apart. Tapes tested as small pancake coils demonstrated the integrity and continuity of the matrix, and showed that critical current was sustained in direct proportion to retained superconductor.

  10. Lower-Thermal-Conductivity Tapes For Tape Automated Bonding

    NASA Technical Reports Server (NTRS)

    Young, Erick T.; Scutero, Michael J.

    1996-01-01

    Foils of manganin substituted for copper foils ordinarily serving as electrical conductors on tapes used in tape automated bonding (TAB) in electronic circuits. Modification makes possible to apply TAB technology to circuits in which substantial gradients of temperature exist under design operating conditions. Other advantages include high reliability, automated assembly, and automated testing.

  11. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  12. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides…

  13. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides…

  14. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  15. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  16. Book Selection from MARC Tapes.

    ERIC Educational Resources Information Center

    Wainwright, Jane; Hills, Jacqueline

    In April 1971 the Aslib Research and Development Department began a study on selective dissemination from MARC tapes. The aim of the project was to explore the technical and economic feasibility of providing selective notifications of current books, by extraction from MARC tapes, to specialized libraries. Typical of the potential customers…

  17. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  18. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  19. Centrally managed tapes at DESY

    SciTech Connect

    Hell, O.

    1994-12-31

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years.

  20. Tape-Smoothing Tool For Adhesion Tests

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1992-01-01

    Small tool smoothes adhesive tape uniformly to ensure consistency and repeatability of tape-peel tests of adhesion of paint to substrate. Includes resilient pad covered with tough, smooth fabric. Internal spring regulates force applied to tape.

  1. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  2. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  3. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  4. Noncontacting ultrasonic and electromagnetic HTS tape NDE

    SciTech Connect

    Telschow, K.L.; Bruneel, F.W.; Walter, J.B.; Koo, L.S.

    1996-10-01

    Two noncontacting nondestructive evaluation techniques (electromagnetic and ultrasonic) for inspection of high temperature superconducting tapes are described. Results for Ag-clad BSCCO tapes are given.

  5. Modeling the effect of initial soil moisture on sorptivity and infiltration

    NASA Astrophysics Data System (ADS)

    Stewart, Ryan; Abou Najm, Majdi; Rupp, David; Selker, John

    2016-04-01

    Soil capillarity, often associated with the parameter sorptivity, is a primary control on infiltration during short-duration rainfall and irrigation events. However, most mathematical models used to quantify capillarity are only valid for dry antecedent conditions. In this study, we examine how the capillary component of sorptivity (i.e., wetting front potential) varies with initial soil water content, and use this finding to provide a simple modification to the classic Green-Ampt sorptivity model. The modified model has many practical applications, including 1) describing the relative sorptivity of a soil at various water contents; 2) quantifying saturated hydraulic conductivity from sorptivity measurements; and 3) interpreting transient time behavior of single ring infiltration (i.e., beerkan) measurements. The model is especially useful in low permeability soils, where steady-state conditions may not be attained for hours or even days, and in shrink-swell soils, where rapid infiltration measurements are often desired so as not to induce substantial material swelling.

  6. Optimum Installation of Sorptive Building Materials Using Contribution Ratio of Pollution Source for Improvement of Indoor Air Quality

    PubMed Central

    Park, Seonghyun; Seo, Janghoo

    2016-01-01

    Reinforcing the insulation and airtightness of buildings and the use of building materials containing new chemical substances have caused indoor air quality problems. Use of sorptive building materials along with removal of pollutants, constant ventilation, bake-out, etc. are gaining attention in Korea and Japan as methods for improving such indoor air quality problems. On the other hand, sorptive building materials are considered a passive method of reducing the concentration of pollutants, and their application should be reviewed in the early stages. Thus, in this research, activated carbon was prepared as a sorptive building material. Then, computational fluid dynamics (CFD) was conducted, and a method for optimal installation of sorptive building materials was derived according to the indoor environment using the contribution ratio of pollution source (CRP) index. The results show that a method for optimal installation of sorptive building materials can be derived by predicting the contribution ratio of pollutant sources according to the CRP index. PMID:27043605

  7. Optimum Installation of Sorptive Building Materials Using Contribution Ratio of Pollution Source for Improvement of Indoor Air Quality.

    PubMed

    Park, Seonghyun; Seo, Janghoo

    2016-04-01

    Reinforcing the insulation and airtightness of buildings and the use of building materials containing new chemical substances have caused indoor air quality problems. Use of sorptive building materials along with removal of pollutants, constant ventilation, bake-out, etc. are gaining attention in Korea and Japan as methods for improving such indoor air quality problems. On the other hand, sorptive building materials are considered a passive method of reducing the concentration of pollutants, and their application should be reviewed in the early stages. Thus, in this research, activated carbon was prepared as a sorptive building material. Then, computational fluid dynamics (CFD) was conducted, and a method for optimal installation of sorptive building materials was derived according to the indoor environment using the contribution ratio of pollution source (CRP) index. The results show that a method for optimal installation of sorptive building materials can be derived by predicting the contribution ratio of pollutant sources according to the CRP index.

  8. The mechano-sorptive behavior of poplar during high-temperature drying

    SciTech Connect

    Dagang, L.; Lianbai, G.

    1999-10-01

    In this study the mechano-sorptive creep perpendicular to the grain was demonstrated by an experimental technique based on the analysis of strain of 30mm thick fast-growing poplar lumber. For levels of drying temperatures (85 C, 105 C, 115 C and 125 C) were used to dry the wood. The overall board shrinkage and the immediately released and set strains were measured as a function of time. The total strain that occurs in lumber drying is the sum of four components: elastic strain, shrinkage strain, visco-elastic creep strain and mechano-sorptive creep strain. The elastic and visco-elastic components of creep are small and produced immediately after the creation of stress. Mechano-sorptive creep is the major strain that causes casehardening during drying.

  9. Asteroid Composite Tape

    NASA Astrophysics Data System (ADS)

    1998-07-01

    This is a composite tape showing 10 short segments primarily about asteroids. The segments have short introductory slides, which include brief descriptions about the shots. The segments are: (1) Radar movie of asteroid 1620 Geographos; (2) Animation of the trajectories of Toutatis and Earth (3) Animation of a landing on Toutatis; (4) Simulated encounter of an asteroid with Earth, includes a simulated impact trajectory; (5) An animated overview of the Manrover vehicle; (6) The Near Earth Asteroid Tracking project, includes a photograph of USAF Station in Hawaii, and animation of Earth approaching 4179 Toutatis and the asteroid Gaspara; (7) live video of the anchor tests of the Champoleon anchoring apparatus; (8) a second live video of the Champoleon anchor tests showing anchoring spikes, and collision rings; (9) An animated segment with narration about the Stardust mission with sound, which describes the mission to fly close to a comet, and capture cometary material for return to Earth; (10) live video of the drop test of a Stardust replica from a hot air balloon; this includes sound but is not narrated.

  10. Canadian Contemporary Issues on Tape

    ERIC Educational Resources Information Center

    Shapter, Jean

    1974-01-01

    Four tapes with interviews with experts in the designated fields comprise the series: a) Canada's Foreign Relations, 1867-1919; b) Canada's Foreign Relations, 1919-1945; c) Canada and China, and d) Canadian Diplomacy and Foreign Policy. (JA)

  11. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  12. How to Tape an Ankle

    MedlinePlus

    ... Materials needed: 1½" athletic tape, Tuf-Skin/Quick Drying Adhesive, two pads to help prevent blistering (2" ... the start of the calf muscle. Use the spray adhesive to help secure the pre-wrap. Apply ...

  13. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  14. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  15. Life without Scissors and Tape

    ERIC Educational Resources Information Center

    Lovell, Donna

    2006-01-01

    My fellow teachers and I took a look at the use of tape and scissors in our 3-6 classroom. We had noticed children's over-reliance on these tools and wondered what would happen if we simply removed them. We decided to initiate a classroom research project in which the students worked for a while without scissors or tape. One goal of the project…

  16. Tape Storage Optimization at BNL

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2011-12-01

    The BNL's RHIC and Atlas Computing Facility (RACF), is supporting the RHIC experiment as its Tier0 center and the Atlas/LHC as a Tier1 center. The RACF had to address the issue of efficient access to data stored to disk and tape storage. Randomly restoring files out of tapes destroys access performance to tape by causing too frequently, high latency and time consuming tape mount and dismount. BNL's mass storage system currently holds more than 16 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on a code from OakRidge National Lab, and then it was renamed to BNL Batch at 2005 after some major modifications and enhancements. The new BNL Batch, ERADAT, provides dynamic HPSS resource management, schedule jobs efficiently, enhanced visibility of real-time staging activities and advanced error handling, to maximize the tape staging performance. ERADAT is the interface between HPSS and other applications such as the DataCarousel, our home developed production system and dCache. Scalla/Xrootd MSS can also be interfaced with HPSS via DataCarousel. ERADAT has demonstrated great performance in BNL and other institute.

  17. What's up with duct tape

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.

    2005-03-01

    Recent research suggests that almost any tape can be made to work for a core-to-collar joint when perfectly applied. Given all the better choices available and all the problems that can and do occur in the field, we would not recommend that cloth-backed (natural) rubber-adhesive tapes be used, unless they can pass a suitable E2343 test. If visual degradation is an important factor, Oriented Polypropylene (OPP) and cloth-backed tapes should be avoided. While tapes that fail usually show visual degradation, the converse is not always true. We speculate, however, that visually degraded tapes are more likely to be susceptible to damage from vibration and other mechanical stresses. Conventional nylon straps are quite prone to fail at higher temperatures, but no systematic studies have yet been done across product classes. UL has proposed a new standard for straps, but the protocol for the current UL test does not, however, suggest that it would be a good indicator of durability. Products meeting the new UL standard for straps should be independently tested for the failure modes observed in the field and laboratory to determine if that test is a reasonable indicator of durability. Until a suitable test for strap durability exists, they recommend that only high temperature nylon or metal straps be used--especially in cases where tapes may be sensitive to mechanical stresses.

  18. The ultratough peeling of elastic tapes from viscoelastic substrates

    NASA Astrophysics Data System (ADS)

    Afferrante, L.; Carbone, G.

    2016-11-01

    The peeling of an elastic thin tape from a flat smooth viscoelastic substrate is investigated. Based on a Green function approach and on the translational invariance, a closed form analytical solution is proposed, which takes into account the viscoelastic dissipation in the substrate material. We find that peeling is prevented from taking place, only when the external force is smaller than the one predicted by Kendall's formula for elastic tapes on rigid substrates. However, we also find that, regardless of the value of the applied force, steady state detachment may occur when the elastic tape is sufficiently stiff. In this case, the constant peeling velocity can be modulated by properly defining the geometrical parameters and the material properties of tape and viscoelastic foundation. On the other hand, for relatively high peeling angles or compliant tapes a threshold value of the peeling force is found, above which the steady-state equilibrium is no longer possible and unstable detachment occurs. The present study contributes to shed light on the behavior of pressure sensitive adhesives in contact with viscoelastic substrates like the human skin. At the same time, it can be considered a first step towards a better understanding of the effect of viscoelastic dissipation on the fracture behavior of solids.

  19. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  20. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    NASA Technical Reports Server (NTRS)

    Kashani, Ali

    2011-01-01

    To increase contact conductance between two mating surfaces, a conductive tape has been developed by growing dense arrays of carbon nanotubes (CNTs, graphite layers folded into cylinders) on both sides of a thermally conductive metallic foil. When the two mating surfaces are brought into contact with the conductive tape in between, the CNT arrays will adhere to the mating surface. The van der Waals force between the contacting tubes and the mating surface provides adhesion between the two mating surfaces. Even though the thermal contact conductance of a single tube-to-tube contact is small, the tremendous amount of CNTs on the surface leads to a very large overall contact conductance. Interface contact thermal resistance rises from the microroughness and the macroscopic non-planar quality of mating surfaces. When two surfaces come into contact with each other, the actual contact area may be much less than the total area of the surfaces. The real area of contact depends on the load, the surface roughness, and the elastic and inelastic properties of the surface. This issue is even more important at cryogenic temperatures, where materials become hard and brittle and vacuum is used, which prevents any gas conduction through the interstitial region. A typical approach to increase thermal contact conductance is to use thermally conducting epoxies or greases, which are not always compatible with vacuum conditions. In addition, the thermal conductivities of these compounds are often relatively low. The CNTs used in this approach can be metallic or semiconducting, depending on the folding angle and diameter. The electrical resistivity of multiwalled carbon nanotubes (MWCNTs) has been reported. MWCNTs can pass a current density and remain stable at high temperatures in air. The thermal conductivity of a MWCNT at room temperature is measured to be approximately 3,000 W/m-K, which is much larger than that of diamond. At room temperature, the thermal conductance of a 0.3 sq cm

  1. Ionic liquids intercalated in montmorillonite as the sorptive phase for the extraction of low-polarity organic compounds from water by rotating-disk sorptive extraction.

    PubMed

    Fiscal-Ladino, Jhon A; Obando-Ceballos, Mónica; Rosero-Moreano, Milton; Montaño, Diego F; Cardona, Wilson; Giraldo, Luis F; Richter, Pablo

    2017-02-08

    Montmorillonite (MMT) clays were modified by the intercalation into their galleries of ionic liquids (IL) based on imidazolium quaternary ammonium salts. This new eco-materials exhibited good features for use as a sorptive phase in the extraction of low-polarity analytes from aqueous samples. Spectroscopic analyses of the modified clays were conducted and revealed an increase in the basal spacing and a shifting of the reflection plane towards lower values as a consequence of the effective intercalation of organic cations into the MMT structure. The novel sorbent developed herein was assayed as the sorptive phase in rotating-disk sorptive extraction (RDSE), using polychlorinated biphenyls (PCBs), representative of low-polarity pollutants, as model analytes. The final determination was made by gas chromatography with electron capture detection. Among the synthetized sorptive phases, the selected system for analytical purposes consisted of MMT modified with the 1-hexadecyl-3-methylimidazolium bromide (HDMIM-Br) IL. Satisfactory analytical features were achieved using a sample volume of 5 mL: the relative recoveries from a wastewater sample were higher than 80%, the detection limits were between 3 ng L(-1) and 43 ng L(-1), the precision (within-run precision) expressed as the relative standard deviation ranged from 2% to 24%, and the enrichment factors ranged between 18 and 28. Using RDSE, the extraction efficiency achieved for the selected MMT-HDMIM-Br phase was compared with other commercial solid phases/supports, such as polypropylene, polypropylene with 1-octanol (as a supported liquid membrane), octadecyl (C18) and octyl (C8), and showed the highest response for all the studied analytes. Under the optimized extraction conditions, this new device was applied in the analysis of the influent of a wastewater treatment plant in Santiago (Chile), demonstrating its applicability through the good recoveries and precision achieved with real samples. Copyright © 2016

  2. Preliminary evaluation of PAH sorptive changes in soil by Soxhlet extraction.

    PubMed

    Hwang, Sangchul; Cutright, Teresa J

    2004-04-01

    This study was conducted to evaluate the influence of sorbent modification by synthetic, chemical/thermal weathering on the sorptive behavior of polycyclic aromatic hydrocarbons (PAHs). A clean sandy-clay-loam soil was subjected to Soxhlet extraction and PAH sorptive phenomena were evaluated based on quantity and quality changes in soil organic matter (SOM) and clay minerals. Critical changes in sorption capacity were found to depend on the initial PAH concentrations. Above 7 mg/l, weathering increased the PAH in comparison to that of unmodified soil, whereas it decreased when applied below this concentration. Similarly, less PAH was desorbed from the altered soil when PAH was applied above 7 mg/l. Therefore, when PAH was applied below 7 mg/l, quantitative reduction of sorbent amount (i.e., SOM and clay minerals) by soil weathering governed PAH sorptive behavior. However, when the PAH was applied above the critical limit, qualitative modifications in the sorbents facilitated an opposite trend. Sorbent swelling, removal of competing compounds, and possible changes in surface characteristics by Soxhlet extraction, together with increased concentration gradient effects were factors that resulted in dissimilar PAH sorptive phenomena, pivoting at the critical concentration.

  3. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  4. Quick-release medical tape.

    PubMed

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M

    2012-11-13

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive-skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes.

  5. Novel digital optical tape recorder

    NASA Astrophysics Data System (ADS)

    Oakley, William S.

    1996-01-01

    A novel very high performance digital optical tape recorder is described. Linear tape motion at 4.2 meters per second and simultaneous writing of about 80 parallel bit tracks with a data density of three bits per micron per track enables a data rate of 1,000 Megabits per second, sufficient for a data rate of 100 megabytes per second with error correction. One micron track to track spacing gives a data capacity of one Terabyte (1,000 GB) in a single '3480' style tape cartridge shell. A single beam from a frequency doubled, laser diode pumped, solid state (2X- LDP-SS) laser is split into a multiplicity of like beams, each of which is then independently modulated at 12.5 MHz for recording.

  6. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  7. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  8. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  9. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  10. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  11. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  12. [Tethered tape or the fourth factor. A new cause of recurrent stress incontinence after midurethral tape procedures vaginal tape insertion].

    PubMed

    Kociszewski, J; Fabian, G; Grothey, S; Viereck, V; Füsgen, I; Wiedemann, A

    2014-01-01

    This is the first report of a newly identified cause of recurrent stress urinary incontinence (SUI) after midurethral tape insertion. This article reports a series of cases with primary or secondary tape failure including clinical presentation and findings, the results of pelvic floor (PF) ultrasound, and the (surgical) correction of malpositioned vaginal tapes. A vaginal tape for treating SUI must be accurately placed under the mid-third of the urethra and at a distance of 3-5 mm from the urethra. Alignment parallel to the urethra in the urethrovaginal septum is also essential for adequate function. A tethered tape refers to the adhesion of a tape edge to the anterior vaginal wall either during primary wound closure or due to secondary ingrowths and is typically associated with recurrent SUI during activities or changes in posture. Less common is SUI through an increase in pressure from cranially, which occurs when coughing or laughing. "Vaginal polyps" may point to imminent vaginal erosion of the tape. In the sagittal plane, the PF examination will identify an oblique orientation of the tape at rest, an abnormal closeness of the tape to the transducer, and changes in tape shape upon manipulation of the vaginal probe. Once the diagnosis has been established, a tethered tape is easy to correct by realignment or tightening to accomplish correct positioning parallel to the urethra. This measure restores tape function and continence. Primary or secondary failure of a tension-free vaginal tape may be caused by a tethered tape. This complication can be diagnosed on the basis of characteristic findings at PF ultrasound. In most women, the tape position can be corrected and there is no need for tape removal.

  13. Patellar taping for patellofemoral pain syndrome in adults.

    PubMed

    Callaghan, Michael J; Selfe, James

    2012-04-18

    Patellofemoral pain syndrome refers to the clinical presentation of knee pain related to changes in the patellofemoral joint. Patellofemoral pain syndrome usually has a gradual onset of pain with none of the features associated with other knee diseases or trauma. It is often treated by physiotherapists, who use a variety of techniques including patellar taping. This involves the application of adhesive sports medical tape applied directly to the skin over the patella on the front of the knee. Patients often report an instantaneous improvement in pain and function after the tape is applied, but its longer term effects are uncertain. The objective was to assess the effects, primarily on pain and function, of patellar taping for treating patellofemoral pain syndrome in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, CINAHL, EMBASE, PEDro, SPORTDiscus, AMED, reference lists of articles, trial registers and conference proceedings. All were searched to August 2011. Randomised controlled trials and quasi-randomised controlled trials testing the effects of patellar taping on clinically relevant outcomes, pain and function, in adults with patellofemoral pain syndrome. We excluded studies testing only the immediate effects of tape application. Both review authors independently performed study selection, data extraction and assessment of risk of bias. Trialists were contacted for more information. Data were pooled where possible. Five small heterogeneous randomised controlled trials, all at high risk of performance bias and most at risk of at least one other type of bias, were included. These involved approximately 200 participants with a diagnosis of patellofemoral pain syndrome. All compared taping versus control (no or placebo taping) and all included one or more co-interventions given to both taping and control group participants; this was prescribed exercise in four

  14. Securing the endotracheal tube with adhesive tape: an integrative literature review.

    PubMed

    Krug, Lois; Machan, Melissa; Villalba, Jose

    2014-12-01

    The practice of securing the endotracheal tube with adhesive tape appears to be benign. However, evidence-based research suggests it is a high-risk practice. Common elements for the taping practice include the tape, anesthesia gas machine, and anesthesia provider. Researchers have found that adhesive tape outside its original packaging became contaminated with pathogens. The bacteria found on the tape included Pseudomonas, Escherichia coli, Klebsiella, Enterobacter, coagulase-positive staphylococci, methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococcal organisms. In addition, a patient does not need to have direct contact with the anesthesia gas machine for pathogen transmission to occur. Anesthesia providers were identified as the origin of bacterial transmission in 12% of cases, with pathogens on their hands 66% of the time. Unfortunately, anesthesia providers are often noncompliant with hand hygiene. They failed to practice hand hygiene 82% of the time. Last, the tape can drop to the floor and harbor pathogens despite cleaning 41.6% of the time; it is often retrieved and reused. All the common elements, independently and collectively, involve the tape and its potential to increase the patient's exposure to pathogens and the risk of infection. This literature review presents evidence-based research regarding endotracheal tube taping practice to ensure patient safety.

  15. A Dry Powder Process for Preparing Uni-Tape Prepreg from Polymer Powder Coated Filamentary Towpregs

    NASA Technical Reports Server (NTRS)

    Wilkinson, Steven P. (Inventor); Johnston, Norman J. (Inventor); Marchello, Joseph M. (Inventor)

    1995-01-01

    A process for preparing uni-tape prepreg from polymer powder coated filamentary towpregs is provided. A plurality of polymer powder coated filamentary towpregs are provided. The towpregs are collimated so that each towpreg is parallel. The sandwich is heated to a temperature wherein the polymer flows and intimately contacts the filaments and pressure is repeatedly applied perpendicularly to the sandwich with a longitudinal oscillating action wherein the filaments move apart and the polymer wets the filaments forming a uni-tape prepreg. The uni-tape prepreg is subsequently cooled.

  16. Dry powder process for preparing uni-tape prepreg from polymer powder coated filamentary towpregs

    NASA Technical Reports Server (NTRS)

    Wilkinson, Steven P. (Inventor); Johnston, Norman J. (Inventor); Marchello, Joseph M. (Inventor)

    1997-01-01

    A process for preparing uni-tape prepreg from polymer powder coated filamentary towpregs is provided. A plurality of polymer powder coated filamentary towpregs are provided. The towpregs are collimated so that each towpreg is parallel. A material is applied to each side of the towpreg to form a sandwich. The sandwich is heated to a temperature wherein the polymer flows and intimately contacts the filaments and pressure is repeatedly applied perpendicularly to the sandwich with a longitudinal oscillating action wherein the filaments move apart and the polymer wets the filaments forming a uni-tape prepreg. The uni-tape prepreg is subsequently cooled.

  17. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  18. A Study of Audio Tape: Part II

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    To evaluate reel audio tape, tests were performed to identify: signal-to-noise ratio, total harmonic distortion, dynamic response, frequency response, biased and virgin tape noise, dropout susceptibility and oxide coating uniformity. (SCC)

  19. A Study of Audio Tape

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    This is part I of a report on a study comparing reel and cassette tapes for signal-to-noise ration, total harmonic distortion, dynamic response, frequency response, bias and virgin noise and oxide coating uniformity. Test equipment and procedures are described and results are discussed. Charts detail research findings. (CHK)

  20. Counseling: Discipline, Tape Cassettes, Occupations

    ERIC Educational Resources Information Center

    Nation's Schools and Colleges, 1975

    1975-01-01

    Special instructional centers in Dade County, Florida, provide tutoring and remedial instruction to suspended students; at the University of Wisconsin (Madison) 225 dial access tape cassettes offer information and advice; and a computer program at Willowbrook High School in Villa Park, Illinois, helps students choose careers. (MLF)

  1. Double-Adhesive Tape Test Reduces Waste

    NASA Technical Reports Server (NTRS)

    Lee, L. C.; Reed, M. W.

    1982-01-01

    New method for testing peel strength of particular thermal-control tape used on Space Shuttle orbiter radiators requires only half amount of tape of method previously employed. Thermal-control tape consists of layers of FEP, silver, Inconel metal, adhesive, Kapton Film, and second adhesive layer. Method also avoids cost of labor and materials to prepare second test coupon and can be adapted for testing other types of double-faced adhesive tapes in military, industrial and consumer applications.

  2. Continuous critical current measurement of high-temperature superconductor tapes with magnetic substrates using magnetic-circuit method.

    PubMed

    Zou, S N; Gu, C; Qu, T M; Han, Z

    2013-10-01

    The critical current (I(c)) of high-temperature superconductor (HTS) tapes has to be examined not only for short samples, but also for the entire tape, because local weak points can possibly lead to the quenching of the whole HTS device. Some methods were reported for continuous I(c) measurement along the length of a HTS tape, but few of them were applicable to tapes with magnetic substrates represented by YBa2Cu3O(7-δ)(YBCO)-coated conductors based on Ni5W alloy substrate by rolling assisted bi-axially textured substrate process. We previously presented a contact-free method using magnetic circuits to measure I(c) continuously of long HTS tapes, namely the magnetic-circuit (MC) method. This method has been previously applied with high speed and resolution to measure I(c) of HTS tapes with non-magnetic substrates, due to its resistance to noise aroused by mechanical vibration. In this work, its ability to measure HTS tapes with magnetic substrates is demonstrated both theoretically and experimentally. A 100 m long commercial YBCO tape based on Ni5W alloy substrate was measured and regular I(c) fluctuations were discovered. The MC method can be a powerful tool for quality control of HTS tapes, especially for tapes with magnetic substrates.

  3. Circular tapered tape fabrication: Final report

    SciTech Connect

    Stockdale, D.A.

    1988-04-01

    A new approach to producing tapered tapes has been developed involving generating a tapered tape in a circular configuration on a lathe rather than a mill. This approach is more cost-effective and the redesigned slot configuration induced less stress on the tapes during installation and removal.

  4. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nystagmus tape. 886.1905 Section 886.1905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a...

  5. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nystagmus tape. 886.1905 Section 886.1905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a...

  6. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nystagmus tape. 886.1905 Section 886.1905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a...

  7. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nystagmus tape. 886.1905 Section 886.1905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a...

  8. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nystagmus tape. 886.1905 Section 886.1905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a...

  9. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  10. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  11. Investigation of electrical characteristics of no-insulation coil wound with surface-processed HTS tape

    NASA Astrophysics Data System (ADS)

    Jeon, Haeryong; Lee, Woo Seung; Kim, Jinsub; Baek, Geonwoo; Jeon, Sangsu; Yoon, Yong Soo; Ko, Tae Kuk

    2017-08-01

    This paper deals with the electrical characteristics of no-insulation coil wound with surface-processed HTS tape. The bypassing current path through turn-to-turn contacts within a coil is formed in the no-insulation coil, and this bypassing current path determines two characteristics: 1) self-protection and 2) charge-discharge delay. The amplitude of bypassing current is determined by contact resistance between the turn-to-turn contacts of the no-insulation coil. The surface roughness of the HTS tape is one of the parameters to change the contact resistance. The HTS tapes were processed to roughen by bead blast and abrasive paper, and the no-insulation coil is fabricated using processed HTS tape. We have studied the charge-discharge delay and self-protecting characteristic of each no-insulation coil by 1) sudden discharge tests and 2) overcurrent tests. The FEM simulations of contact resistance of no-insulation coil were carried out. The contact surface resistance of a case processed by abrasive paper has almost three times larger than that of reference no-insulation coil, and a case processed by bead blast presents almost same contact surface resistance with reference no-insulation coil.

  12. Optical and sorptive properties of cellulose fiber by infrared spectroscopy methods

    NASA Astrophysics Data System (ADS)

    Vaicikauskas, Viktoras V.; Svedas, Vitas; Januskevicius, Regimantas

    1997-02-01

    Optical and sorptive properties of cellulose have been investigated by three methods covering the wide 7000 - 80 cm-1 spectral range. Attenuated total reflection spectra showed shift of sorbed water bands to shorter wavelengths under paper moisture increase. Surface electromagnetic waves (SEW) propagation at metal - Ge (film) - paper system were investigated firstly in far infrared region. Four slopes in the SEW intensity dependence versus time under paper drying were observed. Near infrared diffuse transmittance revealed a band of bonded to cellulose water at 1.53 micrometers which shows 0.08 micrometer red shift compared to 1.45 micrometer band of free water. Damping constants of cellulose sheets of various thickness were determined in the 140 - 85 cm-1 range by the surface electromagnetic wave method. Sorptive properties of cellulose are compared to those of other sorbers made of divided silica.

  13. Permeable sorptive walls for treatment of hydrophobic organic contaminant plumes in groundwater

    SciTech Connect

    Grathwohl, P.; Peschik, G.

    1997-12-31

    Highly hydrophobic contaminants are easily adsorbed from aqueous solutions. Since for many of these compounds sorption increases with increasing organic carbon content natural materials such as bituminous shales and coals may be used in permeable sorptive walls. This, however, only applies if sorption is at equilibrium, which may not always be the case in groundwater treatment using a funnel-and-gate system. In contrast to the natural solids, granular activated carbons (GACs) have very high sorption capacities and reasonably fast sorption kinetics. The laboratory results show that application of GACs (e.g. F100) is economically feasible for in situ removal of polycyclic aromatic hydrocarbons (PAH) from groundwater at a former manufactured gas plant site (MGP). For less sorbing compounds (such as benzene, toluene, xylenes) a combination of adsorption and biodegradation is necessary (i.e. sorptive + reactive treatment).

  14. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  15. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  16. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  17. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  18. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  19. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  20. Acrylic emulsion binder for tape casting

    SciTech Connect

    Tang, X.; Ibbitson, S.A.; Donato, A.T.

    1996-06-01

    A crosslinkable acrylic emulsion binder has been demonstrated to significantly increase tensile strength of green tapes. A low Tg acrylic emulsion binder is blended with the crosslinkable binder to retain flexibility and elasticity of green tapes. The tensile strength of green tapes can be increased from 1.19 MPa to 2.34 MPa by incorporating a crosslinkable binder into the formulation while the tapes remain flexible and elastic with {approximately}15% strain at break. Upon stretching, the green tapes do not yield before breaking. Increasing the drying temperature appears to slightly increase the tensile strength of the green tapes, and has a marginal effect on the strain at break of the tapes. This binder system does not liberate formaldehyde as a result of crosslinking.

  1. Weathering products of basic rocks as sorptive materials of natural radionuclides

    SciTech Connect

    Omelianenko, B.I.; Niconov, B.S.; Ryzhov, B.I.; Shikina, N.D.

    1994-06-01

    The principal requirements for employing natural minerals as buffer and backfill material in high-level waste (HLW) repositories are high sorptive properties, low water permeability, relatively high thermal conductivity, and thermostability. The major task of the buffer is to prevent the penetration of radionuclides into groundwater. The authors of this report examined weathered basic rocks from three regions of Russia in consideration as a suitable radioactive waste barrier.

  2. High density tape casting system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1989-01-01

    A system is provided for casting thin sheets (or tapes) of particles bound together, that are used for oxygen membranes and other applications, which enables the particles to be cast at a high packing density in a tape of uniform thickness. A slurry contains the particles, a binder, and a solvent, and is cast against the inside walls of a rotating chamber. Prior to spraying the slurry against the chamber walls, a solvent is applied to a container. The solvent evaporates to saturate the chamber with solvent vapor. Only then is the slurry cast. As a result, the slurry remains fluid long enough to spread evenly over the casting surface formed by the chamber, and for the slurry particles to become densely packed. Only then is the chamber vented to remove solvent, so the slurry can dry. The major novel feature is applying solvent vapor to a rotating chamber before casting slurry against the chamber walls.

  3. Experimental approach to assess sorptive loss properties of volatile organic compounds in the sampling bag system.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2012-11-01

    In this study, the sorptive loss patterns for volatile organic compounds were evaluated by gaseous standards containing 13 compounds (benzene, toluene, styrene, p-xylene, methyl ethyl ketone, methyl isobutyl ketone, isobutyl alcohol, butyl acetate, acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde). The gaseous standards, prepared initially at two contrasting concentration levels (40 and 4000 ppb) in a polyester aluminum bag, were measured after two consecutive transfers into empty bags. It indicates that the percent loss patterns, if assessed for all 13 target compounds, are affected most sensitively by the initial concentration levels of samples to yield 2.62 ± 2.22% (at 40 ppb) and 9.57 ± 6.74% (at 4000 ppb). Moreover, the sorptive loss patterns at high concentration samples (4000 ppb) tend to increase in relation with increasing molecular weight of target compounds, although such pattern disappears in low concentration samples (40 ppb). The observed loss patterns, if evaluated in relation to some key parameters like concentration or compound type, suggest the possibility that the sorptive loss of target compounds in storage media can occur in a predictable manner. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Application of heuristic optimization techniques and algorithm tuning to multilayered sorptive barrier design.

    PubMed

    Matott, L Shawn; Bartelt-Hunt, Shannon L; Rabideau, Alan J; Fowler, K R

    2006-10-15

    Although heuristic optimization techniques are increasingly applied in environmental engineering applications, algorithm selection and configuration are often approached in an ad hoc fashion. In this study, the design of a multilayer sorptive barrier system served as a benchmark problem for evaluating several algorithm-tuning procedures, as applied to three global optimization techniques (genetic algorithms, simulated annealing, and particle swarm optimization). Each design problem was configured as a combinatorial optimization in which sorptive materials were selected for inclusion in a landfill liner to minimize the transport of three common organic contaminants. Relative to multilayer sorptive barrier design, study results indicate (i) the binary-coded genetic algorithm is highly efficient and requires minimal tuning, (ii) constraint violations must be carefully integrated to avoid poor algorithm convergence, and (iii) search algorithm performance is strongly influenced by the physical-chemical properties of the organic contaminants of concern. More generally, the results suggest that formal algorithm tuning, which has not been widely applied to environmental engineering optimization, can significantly improve algorithm performance and provide insight into the physical processes that control environmental systems.

  5. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  6. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  7. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  8. Comanche Helmet-Mounted Display Heading-Tape Simulation

    NASA Technical Reports Server (NTRS)

    Turpin, Terry; Dowell, Susan; Atencio, Adolph

    2006-01-01

    The Aeroflightdynamics Directorate (AMRDEC) conducted a simulation to assess the performance associated with a Contact Analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a Compressed heading tape similar to that specified by the former Military Standard (MIL-STD) 1295. Six experienced pilots flew three modified Aeronautical Design Standards (ADS)-33 maneuvers (Hover Turn, Bob-up, Transient Turn) and a precision traffic pattern in the NASA Vertical Motion Simulator (VMS). Analysis of the pilot objective performance data and subjective handling qualities ratings (HQRs) showed the following: Compressed symbology in the Velocity Stabilization (VelStab) flight mode generally produced the most precise performances over Contact Analog symbology with respect to the heading, altitude, position, and time criteria specified for the maneuvers tested. VelStab outperformed the Automatic Flight Control System (AFCS) on all maneuvers achieving desired performance on most maneuvers for both symbol sets. Performance in the AFCS mode was generally desirable to adequate for heading and altitude and did not meet adequate standards for hover position and time for the Hover Turn and Bob-up maneuvers. VelStab and AFCS performance were nearly the same for the Transient Turn. Pilot comments concerning the Contact Analog heading-tape implementation were generally unfavorable in spite of the achieved levels of performance. HQRs showed Compressed symbology in the VelStab flight mode produced the lowest mean HQR, encompassing mixed ratings of satisfactory handling and needing improvement. All other symbology/flight-mode combinations yielded higher HQRs, which characterized opinions that deficiencies in aircraft handling due to HMD symbology would need improvement. Contact Analog heading tape and other symbology require improvement, especially when operating in the AFCS mode. NASA-TLX rated Compressed symbology

  9. An Improvement in Thermal Modelling of Automated Tape Placement Process

    SciTech Connect

    Barasinski, Anaies; Leygue, Adrien; Poitou, Arnaud; Soccard, Eric

    2011-01-17

    The thermoplastic tape placement process offers the possibility of manufacturing large laminated composite parts with all kinds of geometries (double curved i.e.). This process is based on the fusion bonding of a thermoplastic tape on a substrate. It has received a growing interest during last years because of its non autoclave abilities.In order to control and optimize the quality of the manufactured part, we need to predict the temperature field throughout the processing of the laminate. In this work, we focus on a thermal modeling of this process which takes in account the imperfect bonding existing between the different layers of the substrate by introducing thermal contact resistance in the model. This study is leaning on experimental results which inform us that the value of the thermal resistance evolves with temperature and pressure applied on the material.

  10. An Improvement in Thermal Modelling of Automated Tape Placement Process

    NASA Astrophysics Data System (ADS)

    Barasinski, Anaïs; Leygue, Adrien; Soccard, Eric; Poitou, Arnaud

    2011-01-01

    The thermoplastic tape placement process offers the possibility of manufacturing large laminated composite parts with all kinds of geometries (double curved i.e.). This process is based on the fusion bonding of a thermoplastic tape on a substrate. It has received a growing interest during last years because of its non autoclave abilities. In order to control and optimize the quality of the manufactured part, we need to predict the temperature field throughout the processing of the laminate. In this work, we focus on a thermal modeling of this process which takes in account the imperfect bonding existing between the different layers of the substrate by introducing thermal contact resistance in the model. This study is leaning on experimental results which inform us that the value of the thermal resistance evolves with temperature and pressure applied on the material.

  11. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  12. The insertion tape: a new circumference tape for use in nutritional assessment.

    PubMed

    Zerfas, A J

    1975-07-01

    Certain body circumferences, such as the mid-upper arm circumference, are regarded as useful indicators of the nutritional status of children. The insertion tape is designed to reduce errors of measurement, prone to occur with the present tapes. At the widened origin of the new tape is a narrow slot perpendicular to the tape's long axis. The measurer threads the distal end of the tape though this slot, tightens to the required tension around the circumference and reads from an open window near the slot. Modifications of the basic tape for specific uses of measurement, screening and survey, are described.

  13. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  14. Aid for electrical contacting of high-temperature fuel cells and method for production thereof

    DOEpatents

    Becker, Ines; Schillig, Cora

    2014-03-18

    A double-sided adhesive metal-based tape for use as contacting aid for SOFC fuel cells is provided. The double-sided metal-based adhesive tape is suitable for simplifying the construction of cell bundles. The double-sided metal-based adhesive tape is used for electrical contacting of the cell connector with the anode and for electrical contacting of the interconnector of the fuel cells with the cell connector. A method for producing the double-sided adhesive metal-base tape is also provided.

  15. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  16. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  17. Effect of crystallographical and geometrical changes of a ferrite head on magnetic signals during the sliding process with magnetic tape

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1986-01-01

    This paper reviews changes in the crystalline structure and geometry of lapped Mn-Zn ferrite heads in sliding contact with magnetic tape and the effects of these changes on magnetic signals. A highly textured, polycrystalline structure was produced on the surface of a single-crystal Mn-Zn ferrite head when it was finished with an aluminum oxide lapping tape. Sliding this lapped surface against a magnetic tape produced a nearly amorphous structure. The sliding process led to a degradation in readback signal of 1 to 2 dB (short-wavelength recording). Furthermore, wear of the magnetic head caused geometrical changes in the head surface. The signal read back with the worn magnetic head was sensitive to operating parameters such as head displacement and tape tension. A change in operating parameters created head-to-tape spacings and, consequently, excessive gains or losses in the readback signal.

  18. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  19. Fabric phase sorptive extraction: An innovative sample preparation approach applied to the analysis of specific migration from food packaging.

    PubMed

    Aznar, M; Alfaro, P; Nerin, C; Kabir, A; Furton, K G

    2016-09-14

    Additives added to food packaging materials can migrate to food in contact with them during storage and shelf life. A novel simple, fast and sensitive analyte extraction method based on fabric phase sorptive extraction (FPSE), followed by analysis using ultra-high performance liquid chromatography and mass spectrometry detection (UPLC-MS) was applied to the analysis of 18 common non-volatile plastic additives. Three FPSE media coated with different sol-gel sorbents characterized with different polarities including sol-gel poly(dimethylsiloxane), sol-gel poly(ethylene glycol) and sol-gel poly(tetrahydrofuran) were studied. All three FPSE media showed very satisfactory results. In general, compounds with low logP values seemed to have higher enrichment factors (EFs), especially with poly(tetrahydrofuran) and poly(ethylene glycol) media. For compounds with high logP values, the use of sol-gel poly(dimethylsiloxane) improved the enrichment capacity. Sample preparation time was optimized at 20 min for sample extraction and 10 min for solvent desorption. Acetonitrile was selected as desorption solvent since recoveries were over 70% for 13 out of 18 selected compounds in all FPSE media. The best extraction recovery values were obtained when compounds were dissolved in aqueous acetic acid solution (3%), where 17 out of 18 compounds showed improvement in their signal intensity after FPSE extraction and 10 obtained enrichment factors above 3 for all the tested FPSE media. When FPSE extracts were concentrated under nitrogen, 11 out of 18 compounds reached EFs values above 100. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Contact dermatitis

    MedlinePlus

    Dermatitis - contact; Allergic dermatitis; Dermatitis - allergic; Irritant contact dermatitis; Skin rash - contact dermatitis ... There are 2 types of contact dermatitis. Irritant dermatitis: This ... can be by contact with acids, alkaline materials such as soaps ...

  1. Fabric phase sorptive extraction: a new sorptive microextraction technique for the determination of non-steroidal anti-inflammatory drugs from environmental water samples.

    PubMed

    Racamonde, Inés; Rodil, Rosario; Quintana, José Benito; Sieira, Benigno José; Kabir, Abuzar; Furton, Kenneth G; Cela, Rafael

    2015-03-20

    Fabric phase sorptive extraction (FPSE) is a new, yet very promising member of the sorbent-based sorptive microextraction family. It has simultaneously improved both the extraction sensitivity and the speed of the extraction by incorporating high volume of sol-gel hybrid inorganic-organic sorbents into permeable fabric substrates. The advantages of FPSE have been investigated for the determination of four non-steroidal anti-inflammatory drugs, ibuprofen, naproxen, ketoprofen and diclofenac, in environmental water samples in combination with gas chromatography-mass spectrometry. Initially, the significance of several parameters affecting FPSE: sorbent chemistry, matrix pH and ionic strength were investigated using a mixed level factorial design (3(1)×2(2)). Then, other important parameters e.g., sample volume, extraction kinetics, desorption time and volume were also carefully studied and optimized. Due to the high sorbent loading on the FPSE substrate in the form of ultra-thin coating and the open geometry of the microextraction device, higher mass transfer of the target analytes occurs at a faster rate, leading to high enrichment factors in a relatively short period of time (equilibrium times: 45-100 min). Under optimal operational conditions, the limits of detection (S/N=3) were found to be in the range of 0.8 ng L(-1) to 5 ng L(-1). The enrichment factors ranged from 162 to 418 with absolute extraction efficiencies varied from 27 to 70%, and a good trueness (82-116% relative recoveries) indicating that the proposed method can be readily deployed to routine environmental pollution monitoring. The proposed method was successfully applied to the analysis of target analytes in two influent and effluent samples from a wastewater treatment plant and two river water samples in Spain.

  2. Occupational exposure to asbestos in the drywall taping process.

    PubMed

    Verma, D K; Middleton, C G

    1980-04-01

    Studies of airborne asbestos fiber concentrations associated with various operations of the drywall taping process have been undertaken in the province of Alberta, Canada. The results show that mixing, sanding and sweeping created high levels of airborne asbestos dust. The measured concentrations were frequently in excess of occupational health standards. Sanding in particular was assessed the most hazardous operation. The results are discussed in light of present and proposed Occupational Health Standards, and in terms of its implications for other workers, household contacts, and consumer's risk. Measures to reduce and control the health hazards associated with the process are described.

  3. Adhesive Contact Sweeper

    NASA Technical Reports Server (NTRS)

    Patterson, Jonathan D.

    1993-01-01

    Adhesive contact sweeper removes hair and particles vacuum cleaner leaves behind, without stirring up dust. Also cleans loose rugs. Sweeper holds commercially available spools of inverted adhesive tape. Suitable for use in environments in which air kept free of dust; optics laboratories, computer rooms, and areas inhabited by people allergic to dust. For carpets, best used in tandem with vacuum cleaner; first pass with vacuum cleaner removes coarse particles, and second pass with sweeper extracts fine particles. This practice extends useful life of adhesive spools.

  4. McConnell taping shifts the patella inferiorly in patients with patellofemoral pain: a dynamic magnetic resonance imaging study.

    PubMed

    Derasari, Aditya; Brindle, Timothy J; Alter, Katharine E; Sheehan, Frances T

    2010-03-01

    Patellar taping is widely used clinically to treat patients with patellofemoral pain syndrome (PFPS). Although patellar taping has been demonstrated to reduce patellofemoral pain in patients with PFPS, the kinematic source for this pain reduction has not been identified. The purpose of this study was to quantify the changes in the 6-degrees-of-freedom patellofemoral kinematics due to taping in patients with PFPS. A within-subject design and a sample of convenience were used. Fourteen volunteers (19 knees) who were diagnosed with patellofemoral pain that was present for a year or longer were included. Each knee had to meet at least 1 of the following inclusion criteria: Q-angle of > or =15 degrees, a positive apprehension test, patellar lateral hypermobility (> or =10 mm), or a positive "J sign." Each knee underwent 2 randomly ordered testing conditions (untaped and taped). A full fast-phase contrast (PC) magnetic resonance image set was acquired for each condition while the participants volitionally extended and flexed their knee. Three-dimensional displacements and rotations were calculated through integration of the fast-PC velocity data. Statistical comparisons between baseline patellofemoral kinematics and the change in kinematics due to taping were performed using a 2-tailed paired Student t test. Correlations between baseline patellofemoral kinematics and the change in kinematics due to taping also were quantified. Patellar taping resulted in a significant patellofemoral inferior shift. The strongest correlation existed between the change in lateral-medial displacement with taping and baseline (r=-.60). The inferior shift in patellar displacement with taping partially explains the previously documented decrease in pain due to increases in contact area. The lack of alteration in 5 of the 6 kinematic variables with taping may have been due to the fact that post-taping kinematic alterations are sensitive to the baseline kinematic values.

  5. Effect of selective sorptive agents on leachability of {sup 137}Cs and {sup 90}Sr

    SciTech Connect

    Spence, R.D.

    1998-06-01

    Decades ago it was established that illite effectively improves {sup 137}Cs leach resistance. Subsequently, illite has become a standard ingredient used at Oak Ridge National Laboratory in grouts developed to stabilize {sup 137}Cs. Adding illite improves {sup 137}Cs leach resistance by three orders of magnitude, and increasing the illite concentration can add another order of magnitude improvement. Adding crystalline silicotitanate, a selective sorptive agent developed more recently for {sup 137}Cs, not only improves {sup 137}Cs leach resistance by an order-of-magnitude over that obtained using illite but also improves {sup 85}Sr leach resistance by two orders of magnitude.

  6. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    NASA Astrophysics Data System (ADS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-11-01

    A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous Ic measurement, we found that our new multi-filamentary tape could provide almost equal Ic compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  7. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  8. Bandaging and taping considerations for the dancer.

    PubMed

    Ewalt, Katherine L

    2010-01-01

    Although widely disputed, bandaging and taping techniques are common practice in sports medicine. This article reviews literature related to the efficacy of bandaging and taping procedures and their role in sport and dance medicine. It further examines dance-specific application principles, and outlines selected techniques for treatment of common dance-related pathologies.

  9. Tape-Assisted Transfer of Carbon Nanotube Bundles for Through-Silicon-Via Applications

    NASA Astrophysics Data System (ADS)

    Mu, Wei; Sun, Shuangxi; Jiang, Di; Fu, Yifeng; Edwards, Michael; Zhang, Yong; Jeppson, Kjell; Liu, Johan

    2015-08-01

    Robust methods for transferring vertically aligned carbon nanotube (CNT) bundles into through-silicon vias (TSVs) are needed since CNT growth is not compatible with complementary metal-oxide-semiconductor (CMOS) technology due to the temperature needed for growing high-quality CNTs (˜700°C). Previous methods are either too complicated or not robust enough, thereby offering too low yields. Here, a facile transfer method using tape at room temperature is proposed and experimentally demonstrated. Three different kinds of tape, viz. thermal release tape, Teflon tape, and Scotch tape, were applied as the medium for CNT transfer. The CNT bundle was adhered to the tape through a flip-chip bonder, and the influence of the bonding process on the transfer results was investigated. Two-inch wafer-scale transfer of CNT bundles was realized with yields up to 97% demonstrated. After transfer, the use of several different polymers was explored for filling the gap between the transferred CNT bundle and the sidewalls of the TSV openings to improve the filling performance. The current-voltage characteristic of the CNT TSVs indicated good electrical performance, and by measuring the via resistance as a function of via thickness, contact resistances could be eliminated and an intrinsic CNT resistivity of 1.80 mΩ cm found.

  10. The Effect of the Kinesio Taping and Spiral Taping on Menstrual Pain and Premenstrual Syndrome

    PubMed Central

    Lim, Chaegil; Park, Yongnam; Bae, Youngsook

    2013-01-01

    [Purpose] The purpose of this study was to compare the effects of Kinesio taping and spiral taping on menstrual pain and premenstrual syndrome, to investigate the efficacy of the two types of taping as methods for alleviating menstrual pain and premenstrual syndrome. [Subjects and Methods] The subjects of this study were 34 unmarried women. The subjects were randomly divided into a Kinesio taping group, a spiral taping group and a control group. Subjects with a regular menstrual cycle underwent taping a total of six times; twice a week for about three weeks, starting from 14 days before menstruation and continuing until its end. Degrees of menstrual pain and premenstrual syndrome were measured before the application of taping. [Results] The results revealed that Kinesio taping had significant effects on menstrual pain, while spiral taping was effective at alleviating both menstrual pain and premenstrual syndrome. [Conclusion] Both taping methods before menstruation brought significant relief to menstrual pain, which suggests that spiral taping is an effective method of alleviating premenstrual symptoms. PMID:24259847

  11. Mechanical stabilization of BSCCO-2223 superconducting tapes

    SciTech Connect

    King, C.G.; Grey, D.A.; Mantone, A.

    1996-12-31

    A system to provide mechanical stabilization to high temperature BSCCO-2223 superconducting tape by laminating 0.081 mm thick, spring hard, copper foil to both sides with lead-tin eutectic solder has been successfully optimized. This system has been applied as a method to create a strong, windable composite from pure silver BSCCO tapes with a minimum of critical current (I{sub c}) degradation. The {open_quotes}as received{close_quotes} conductor is evaluated for physical consistency of width and thickness over the 3000 meters that were later strengthened, insulated and wound into a demonstration coil. Electrical degradation in the strengthened tape as a result of lamination was found to average 24 percent with a range from 4 to 51 percent. This was less than the degradation that would have occurred in an unstrengthened tape during subsequent insulation and coil winding processes. Additional work was performed to evaluate the mechanical properties of the strengthened tapes. The copper can double the ultimate tensile strength of the pure silver tapes. Additionally, pure silver and dispersion strengthened silver matrix tapes are laminated with 0.025 mm thick copper and 304 stainless steel foil to investigate minimization of the cross sectional area of the strengthening component. The stainless steel can increase the UTS of the pure silver tapes sixfold. Metallography is used to examine the laminate and the conductor. Mechanical properties and critical currents of these tapes are also reported both before and after strengthening. The I{sub c} is also measured as a function of strain on the laminated tapes.

  12. Demonstration project cuts red tape

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    Results from a demonstration project aimed at cutting red tape in federal grants for basic research at universities are "very encouraging" so far, according to Don I. Phillips, executive director of the Government-University-Industry Research Roundtable. The roundtable is coordinating the experimental effort, with the participation of five major federal agencies as well as the Florida state university system and the University of Miami (a private institution in Coral Gables, Fla.).Under the project, special conditions apply to grants from the participating agencies to individual researchers at the participating universities: Investigators do not have to ask the agency's permission for changes in budget allocations, purchases of permanent equipment, or foreign travel. Grant money can be spent up to a year after the grant ends without a special request. Under this plan, researchers, with agency approval, can also ask to have their entire research program covered as a single administrative entity, rather than as several individual projects.

  13. Randomized comparison of a silicone tape and a paper tape for gentleness in healthy children.

    PubMed

    Grove, Gary L; Zerweck, Charles R; Ekholm, Bruce P; Smith, Graham E; Koski, Nancy I

    2014-01-01

    To compare the relative gentleness of a silicone tape to a paper tape in healthy infants and children. A randomized, grader-blinded, comparative study. The sample group comprised 24 healthy infants and children 9.1 to 46.7 months of age (mean ± SEM, 34.0 ± 2.21). The study was conducted at a dermatological research facility (cyberDERM, Inc) located in Broomall, Pennsylvania. All volunteers were recruited from the surrounding community. Tapes measuring 1 × 1.5 inches were randomly applied to the left and right intrascapular regions of the upper back. Tapes were removed in a standardized fashion after 24 hours. The primary study outcome, gentleness, was based on visual assessments of skin damage, discomfort, and quantification of keratin removal. Four-point scales were used to assess skin damage, and a 10-point Faces, Legs, Activity, Cry, and Consolability instrument was used to assess discomfort. Secondary assessments included hair removal, tape edge-lift assessments, and parent preference for either tape. There was a significantly lower mean ± SEM erythema response for the silicone tape (0.93 ± 0.14 vs 1.35 ± 0.11, P = .0129) than for the paper tape. No measurable epidermal stripping occurred with the silicone tape compared to a mean ± SEM response of 0.29 ± 0.11 for the paper tape (P = .0039). Discomfort was significantly lower (P = .0002) for the silicone tape as compared to the paper tape (Faces, Legs, Activity, Cry, and Consolability score mean difference from baseline 0.5 vs 3.3, P = .0002). Keratin removal was significantly less with the silicone as compared to paper tape (8.7 ± 0.5 μg/mL vs 15.2 ± 1.3 μg/mL, P < .0001). Few hairs were removed with either tape. There was significantly less (P < .0001) edge-lift with the paper tape than the silicone tape; no statistically significant differences in parent preferences for silicone versus paper tapes were measured (P = .3359). Gentleness assessments favored the silicone tape compared to a paper tape

  14. Relaxation Training: A Guide for Developing Teacher-Made Tapes.

    ERIC Educational Resources Information Center

    Wells, Donald H.

    1983-01-01

    Teachers can develop tapes to help special education students systematically reduce muscle tension. Tapes should focus on breathing exercises and muscle relaxation exercises. Resources are included. (CL)

  15. Investigation of AC losses in horizontally parallel HTS tapes

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Li, Jing; Geng, Jianzhao; Fu, Lin; Zhang, Xiuchang; Zhang, Heng; Li, Chao; Grilli, Francesco; Coombs, T. A.

    2017-07-01

    This paper presents an AC loss study of horizontally parallel HTS tapes. We proposed to use three parallel HTS tapes as an example. The AC losses of the middle and end tape of three parallel tapes have been measured using the electrical method and compared to those of an individual tape. The effect of the interaction between tapes on AC losses has been analysed, and compared with finite-element method (FEM) simulations using the 2D H -formulation implemented in COMSOL Multiphysics. By using FEM simulations, the cases of increasing number of parallel tapes have been considered, and the normalised ratio between the total average AC losses per tape and the AC losses of an individual single tape has been calculated for different gap distances. We proposed a new parameter, Ns , a turning point for number of tapes, to divide Stage 1 and Stage 2 for the AC loss study of horizontally parallel tapes. For Stage 1, N < Ns , the total average losses per tape increased with the increasing number of tapes. For Stage 2, N > Ns , the total average losses per tape decrease with the increasing number of tapes. The analysis demonstrates that horizontally parallel HTS tapes could be potentially used in superconducting devices like HTS transformers, which could retain or even reduce the total average AC losses per tape with large number of parallel tapes.

  16. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  17. Reliable metallic tape connection on CIGS solar cells by ultrasonic bonding

    NASA Astrophysics Data System (ADS)

    Xu, Tao; Valentin, Orlando; Luechinger, Christoph

    2010-09-01

    Metallic tapes are used to reliably connect CIGS thin-film solar panels to the junction box. Compared to soldering and gluing, ultrasonically bonding these tapes offers several benefits: a room-temperature process, lower consumable cost, stronger and more reliable bonds, and lower contact resistance. A MoSe2 layer can form on the back contact Mo layer during the CIGS selenization. The thickness of the MoSe2 layer varies with the details of the deposition and selenization process. MoSe2 is a solid lubricant that creates a low friction interface between the tape and Mo layer, thus reducing ultrasonic coupling and making ultrasonic bonding more challenging. MoSe2 also has a volume resistivity about 3,500 times higher than Mo. Its presence increases the tape contact resistance and thus reduces the efficiency of the solar module. It is therefore desired to remove the MoSe2 layer to make a reliable connection. Several processes were investigated on samples with varying MoSe2 layer thickness. The effectiveness of those processes was studied and evaluated by using Scanning Electron Microscope (SEM), Energy Dispersive X-ray Analysis (EDAX), 90° bond peel test, and electrical contact resistance measurements. Complete removal of the MoSe2 layer without damaging the Mo layer underneath was successfully achieved. Strong bonds with more than 900g peel force for 2.00mm (width) × 0.10mm (thickness) Aluminum tapes and a low contact resistivity of <1.5 mΩcm2 were consistently demonstrated.

  18. Field performance of dieldrin/resin wettable powders on sorptive mud surface.

    PubMed

    VAN TIEL, N

    1961-01-01

    Recent field experiments on the relative performance of dieldrin and dieldrin/resin wettable powders on sorptive mud surface have not confirmed the promising results obtained with the latter products in earlier laboratory tests. In view of this a renewed investigation into the possible factors governing the performance of such products was considered desirable, and further laboratory and field experiments were carried out in co-operation with the Colonial Pesticides Research Unit at Arusha, Tanganyika.The results of these experiments have given a better understanding of the factors involved, and a coherent interpretation of the differences in performance shown by various products under different conditions. The main factors to be taken into account appear to be: mobility of the insects during exposure, as influenced by insect species and exposure conditions; inherent toxicity of the dieldrin/resin particles; and the average relative humidity inside the experimental huts.The sorption phenomenon can be demonstrated in the field, but in view of the humidity conditions it does not seem likely that it will interfere seriously with practical mosquito control. A potential critical condition might be prevalent only in areas where the presence of sorptive mud is coupled with long periods of low humidity inside the huts, but further experimental data are necessary to confirm this.

  19. Stir bar sorptive extraction for the determination of volatile compounds in oak-aged wines.

    PubMed

    Marín, J; Zalacain, A; De Miguel, C; Alonso, G L; Salinas, M R

    2005-12-09

    Stir bar sorptive extraction (SBSE) followed by a thermal desorption-gas chromatography-mass spectrometry analysis has been optimized for the determination of 13 of the most important oak volatiles in wine samples, all in a single run. The stir bar sorptive extraction method was optimized in terms of temperature, time, pH and NaCl addition, and the best results were obtained after stirring the wine sample with the polydimethylsiloxane stir bar during 90min at room temperature. The addition of sodium chloride did not enhance the volatile extraction. The method proposed showed good linearity over the concentration range tested, with correlation coefficients ranging from 0.92 to 0.99 for all the analytes. The reproducibility and repeatability of the method was estimated between 0.11 and 5.45%. The detection and quantification limits of all analytes were lower than their respective olfactory threshold values, and, most importantly, no artifacts have been observed during the analysis as described in most extractions using other current methodologies.

  20. Field Performance of Dieldrin/Resin Wettable Powders on Sorptive Mud Surface

    PubMed Central

    Van Tiel, N.

    1961-01-01

    Recent field experiments on the relative performance of dieldrin and dieldrin/resin wettable powders on sorptive mud surface have not confirmed the promising results obtained with the latter products in earlier laboratory tests. In view of this a renewed investigation into the possible factors governing the performance of such products was considered desirable, and further laboratory and field experiments were carried out in co-operation with the Colonial Pesticides Research Unit at Arusha, Tanganyika. The results of these experiments have given a better understanding of the factors involved, and a coherent interpretation of the differences in performance shown by various products under different conditions. The main factors to be taken into account appear to be: mobility of the insects during exposure, as influenced by insect species and exposure conditions; inherent toxicity of the dieldrin/resin particles; and the average relative humidity inside the experimental huts. The sorption phenomenon can be demonstrated in the field, but in view of the humidity conditions it does not seem likely that it will interfere seriously with practical mosquito control. A potential critical condition might be prevalent only in areas where the presence of sorptive mud is coupled with long periods of low humidity inside the huts, but further experimental data are necessary to confirm this. PMID:13780061

  1. [Analysis of part of flavor compounds in wheat by headspace sorptive extraction-gas chromatography].

    PubMed

    Wang, Tongbo; Yan, Xiao; Lan, Xiaozheng

    2013-05-01

    A method has been established for the analysis of flavor compounds in wheat by headspace sorptive extraction (HSSE). The sorptive extraction bar was composed of a silicon rubber coating and a capillary glass with an inner iron rod. The silicon rubber coating was condensed inside a stainless steel mold from the silicon precursors with a sol-hot air vulcanization method. The coating of the extraction bar has a volume of about 87 microL and is thermally stable until 390 degrees C. The flavor compounds extracted by the bar were desorbed in a homemade thermal desorption unit (TDU) and introduced directly into a pre-column in a gas chromatograph for analysis. Experimental parameters for the extraction efficiency were optimized including extraction temperature and time, phase ratio and thermal desorption conditions. The standard wheat flour samples spiked with seven flavor compounds were analyzed under the optimized conditions, and showed good linear relationships (r > 0.9979), limits of detection (LOD) of 0.09 - 1.00 microg/kg, good recoveries (95% - 121%) and repeatabilities (relative standard deviations, RSD, 2.2% - 7.8%). By external calibration method, the absolute contents of the seven flavor compounds in a real wheat sample were determined. The method is rapid, simple with low limits of detection, and is applicable for the rapid quantitative analysis of the flavor compounds in wheat.

  2. Tape Versus Suture in Arthroscopic Rotator Cuff Repair: Biomechanical Analysis and Assessment of Failure Rates at 6 Months.

    PubMed

    Liu, Rui Wen; Lam, Patrick Hong; Shepherd, Henry M; Murrell, George A C

    2017-04-01

    Rotator cuff retears after surgical repair are associated with poorer subjective and objectives clinical outcomes than intact repairs. The aims of this study were to (1) examine the biomechanical differences between rotator cuff repair using No. 2 suture and tape in an ovine model and (2) compare early clinical outcomes between patients who had rotator cuff repair with tape and patients who had repair with No. 2 suture. Controlled laboratory study and cohort study; Level of evidence, 3. Biomechanical testing of footprint contact pressure and load to failure were conducted with 16 ovine shoulders using a tension band repair technique with 2 different types of sutures (No. 2 suture [FiberWire; Arthrex] and tape [FiberTape; Arthrex]) with the same knotless anchor system. A retrospective study of 150 consecutive patients (tape, n = 50; suture, n = 100) who underwent arthroscopic rotator cuff repair by a single surgeon with tear size larger than 1.5 × 1 cm was conducted. Ultrasound was used to evaluate the repair integrity at 6 months postsurgery. Rotator cuff repair using tape had greater footprint contact pressure (mean ± standard error of the mean, 0.33 ± 0.03 vs 0.11 ± 0.3 MPa; P < .0001) compared with repair using No. 2 sutures at 0° abduction with a 30-N load applied across the repaired tendon. The ultimate failure load of the tape repair was greater than that for suture repair (217 ± 28 vs 144 ± 14 N; P < .05). The retear rate was similar between the tape (16%; 8/50) and suture groups (17%; 17/100). Rotator cuff repair with the wider tape compared with No. 2 suture did not affect the retear rate at 6 months postsurgery, despite having superior biomechanical properties.

  3. High-Density-Tape Casting System

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1987-01-01

    Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

  4. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  6. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain.

  7. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain. PMID:26311991

  8. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-07-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain.

  9. Effect of Model Sorptive Phases on Phenanthrene Biodegradation: Different Enrichment Conditions Influence Bioavailability and Selection of Phenanthrene-Degrading Isolates

    PubMed Central

    Grosser, Robert J.; Friedrich, Michael; Ward, David M.; Inskeep, William P.

    2000-01-01

    The sorption of organic contaminants by natural organic matter (NOM) often limits substrate bioavailability and is an important factor affecting microbial degradation rates in soils and sediments. We hypothesized that reduced substrate bioavailability might influence which microbial assemblages are responsible for contaminant degradation under enrichment culture conditions. Our primary goal was to characterize enrichments in which different model organic solid phases were used to establish a range of phenanthrene bioavailabilities for soil microorganisms. Phenanthrene sorption coefficients (expressed as log KD values) ranged from 3.0 liters kg−1 for Amberlite carboxylic acid cation-exchange resin (AMB) to 3.5 liters kg−1 for Biobeads polyacrylic resin (SM7) and 4.2 liters kg−1 for Biobeads divinyl benzene resin (SM2). Enrichment cultures were established for control (no sorptive phase), sand, AMB, SM7, and SM2 treatments by using two contaminated soils (from Dover, Ohio, and Libby, Mont.) as the initial inocula. The effects of sorption by model phases on the degradation of phenanthrene were evaluated for numerous transfers in order to obtain stable microbial assemblages representative of sorptive and nonsorptive enrichment cultures and to eliminate the effects of the NOM present in the initial inoculum. Phenanthrene degradation rates were similar for each soil inoculum and ranged from 4 to 5 μmol day−1 for control and sand treatments to approximately 0.4 μmol day−1 in the presence of the SM7 sorptive phase. The rates of phenanthrene degradation in the highly sorptive SM2 enrichment culture were insignificant; consequently, stable microbial populations could not be obtained. Bacterial isolates obtained from serial dilutions of enrichment culture samples exhibited significant differences in rates of phenanthrene degradation performed in the presence of SM7, suggesting that enrichments performed in the presence of a sorptive phase selected for different

  10. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  11. Urinary incontinence - tension-free vaginal tape

    MedlinePlus

    ... place) Damage to the urethra, bladder, or vagina Erosion of the tape into surrounding normal tissues (urethra ... told to take with a small sip of water. Your doctor or nurse will tell you when ...

  12. Video Tape and the Mentally Retarded

    ERIC Educational Resources Information Center

    Weisbord, H. F.

    1972-01-01

    Three uses of video tape recordings with the mentally retarded; discussed briefly are staff training or teacher education, parental involvement in the child's education, and therapeutic uses by psychiatrists and psychologists. (CB)

  13. New energy storage concept uses tapes

    NASA Technical Reports Server (NTRS)

    Gruber, A.; Kafesjian, R. R.

    1966-01-01

    Energy storage system uses movable permeable tapes with cathode and electrolyte material that is drawn across an anode to produce electric power. The system features long shelf life, high efficiency, and flexible operation.

  14. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  15. Operating time meter for tape recorder

    NASA Astrophysics Data System (ADS)

    Ganzburg, M.; Dyuffel, O.

    1985-03-01

    As an alternative to standard tape counters for popular tape recorders, a photo-electric device for measuring operating time so as to give a precise reading of expended and available operating time. The device consists of two optical components in a slotted cylinder attached to the rubberized free-wheeling tension wheel. The first, third and fourth discharge circuits have a calculation coefficient of 10, the second, of 6. Technical features are diagrammed and described. The three components include the mechanical tension wheel and the plate on which the light- and photodiodes are mounted, the basic meter plate and light diode indicators and related components. If quality parts are properly mounted, no calibration is required. Features of mechanical tape regulation permitting smooth monitoring of tape movement may make the photoelectric device described unnecessary.

  16. Tape Lift Sampling of Chemical Threat Agents.

    PubMed

    Brady, Krista; Stilley, Becky; Olds, Maria; O'Neill, Terry; Egan, James; Durnal, Evan

    2017-07-01

    Commercial-off-the-shelf (COTS) materials were evaluated as surface samplers for the Department of Homeland Security Chemical Forensics Program. The program helps evidence collectors identify trace chemical residues at incident scenes. COTS items are widely available, produced in large lots, and with strict controls. Chemical attribution signatures were collected from common surfaces. Eight tape lift candidates were considered, five were chosen based on performance and tested for analytical interferences and extraction efficiencies with 14 chemicals. Three products (duct tape, print lifters, command strips) were evaluated for uptake from common interior surfaces (glass, tile, ABS plastic). Duct tape provided highest recoveries across all surfaces. Even the most volatile analytes were detected in the ABS plastic samples (nondetections in others), regardless of tape lift material used. The porous plastic substrate provides better target retention than glass and tile surfaces. Forensic field operators should sample surfaces made of ABS plastic (keyboards, remotes, phones, etc.) whenever possible. © 2017 American Academy of Forensic Sciences.

  17. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  18. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... tape. 908.7116 Section 908.7116 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  19. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... tape. 908.7116 Section 908.7116 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  20. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... tape. 908.7116 Section 908.7116 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  1. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... tape. 908.7116 Section 908.7116 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  2. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  3. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability

    PubMed Central

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-01-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability. PMID:26311206

  4. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability.

    PubMed

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-07-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability.

  5. Read/write head for a magnetic tape device having grooves for reducing tape floating

    DOEpatents

    Aoki, Kenji

    2005-08-09

    A read/write head for a magnetic tape includes an elongated chip assembly and a tape running surface formed in the longitudinal direction of the chip assembly. A pair of substantially spaced parallel read/write gap lines for supporting read/write elements extend longitudinally along the tape running surface of the chip assembly. Also, at least one groove is formed on the tape running surface on both sides of each of the read/write gap lines and extends substantially parallel to the read/write gap lines.

  6. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  7. Program Documentation Report: STD Tape Copy Programs,

    DTIC Science & Technology

    Berman Model 9040 STD probe and 1014 data logger. The programs are written in FORTRAN IV and IBM 360 ASSEMBLAR COMPUTER LANGUAGES. Data tapes from the... STD in 7 track format are read in ASSEMBLAR Language and a 9 track FORTRAN readable tape produced. Printouts from the programs record the number of data points recovered and also list the bad data points (if any). (Author)

  8. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  9. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  10. Studies on the frictional behavior of magnetic recording tapes

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.; Silver, R. H.; Hoffman, J. K.

    1972-01-01

    Methods were developed for measuring frictional forces acting on a magnetic tape in motion or at rest, as well as the extent of stick slip. The effects of factors such as temperature, humidity, kind of gaseous atmosphere, and tape speed on the frictional interaction between various tapes and heads were investigated. Results were instrumental in the selection of a tape for the Mariner Mars 1971 spacecraft. Studies are reported on the stick slip behavior of tapes and the performance of a metallic tape, compared with the usual plastic tapes.

  11. Extubation force: tape versus endotracheal tube holders.

    PubMed

    Carlson, Jestin; Mayrose, James; Krause, Richard; Jehle, Dietrich

    2007-12-01

    Tape is the standard method for securing endotracheal tubes to prevent extubation. This study examines the force required to extubate endotracheal tubes from cadavers with either tape or one of 4 commercially available endotracheal tube holders. Newly deceased, unembalmed cadavers were intubated with standard tracheal intubation techniques. The endotracheal tube was secured with either tape or one of 4 commercially available endotracheal tube holders. The endotracheal tube was then connected to a force-measuring device and pulled until the cuff was removed from the trachea. The largest force recorded on the device was then marked as the "extubation force" for that trial. When tape was used to secure the endotracheal tube, it required a significantly larger force to extubate than 3 of 4 off-the-shelf endotracheal tube holders. Only the Thomas Tube Holder secured the endotracheal tube better than tape. Although the Thomas Tube Holder had the greatest holding force in this study, tape was shown to be the least expensive and outperformed 3 other commercially available devices used to secure endotracheal tubes.

  12. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  13. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  14. Determination of free medium-chain fatty acids in beer by stir bar sorptive extraction.

    PubMed

    Horák, Tomás; Culík, Jirí; Jurková, Marie; Cejka, Pavel; Kellner, Vladimír

    2008-07-04

    Free medium-chain fatty acids in beer originate from raw materials, mainly from the fermentation activity of yeasts, and can influence beer taste, vitality of yeasts and also the foam stability of beer. This study presents the development of the method for the determination of free fatty medium-chain acids including caproic acid, caprylic acid, capric acid and lauric acid in beer or wort using stir bar sorptive extraction (SBSE). The combination of this extraction technique with solvent back extraction of the extracted analytes and subsequent gas chromatographic analysis with flame ionization detection was used for the determination of these compounds. The influences of different solvent back solutions, sampling time, solvent back extraction times and different contents of ethanol were studied. The method had high repeatability (RSD <6.7%), good linearity (the correlation coefficients were higher than 0.9963 for quadratic curves over the concentration range 0.5-8.0mg/l) and recoveries 57-89%.

  15. Headspace sorptive extraction for the detection of combustion accelerants in fire debris.

    PubMed

    Cacho, J I; Campillo, N; Aliste, M; Viñas, P; Hernández-Córdoba, M

    2014-05-01

    A novel method for separation and identification of ignitable liquid residues in fire debris by gas chromatography and mass spectrometry is presented. Preconcentration of the analytes was carried out using the simple headspace sorptive extraction (HSSE) technique. Polydimethylsiloxane stir bars were used as the enrichment phase, and parameters affecting both the adsorption and desorption stages were carefully optimized. Extraction was carried out at 50°C for 1h. Stir bars were desorbed thermally in the GC injection port, thus avoiding the use of organic solvents. The results for five ignitable liquids, including gasoline and diesel fuel, using HSSE were compared with those obtained with a solid-phase microextraction method, with HSSE appearing as a more sensitive alternative.

  16. Analysis of volatiles of malt whisky by solid-phase microextraction and stir bar sorptive extraction.

    PubMed

    Demyttenaere, Jan C R; Martínez, Jorge I Sánchez; Verhé, Roland; Sandra, Pat; De Kimpe, Norbert

    2003-01-24

    Blended Scotch whisky was analysed by solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) to study the composition of the volatiles. For SPME analysis, three different fibres were compared, poly(dimethylsiloxane) (PDMS) (100 microm). poly(acrylate) (PA) (85 microm) and divinylbenzene-Carboxen on poly(dimethylsiloxane) (DVB-CAR-(PDMS) (50/30 microm). It was found that the PDMS and DVB-CAR-PDMS fibres showed a higher enrichment capacity than PA as well as a better reproducibility. The influence of sampling time, temperature and salt addition on the enrichment of volatiles as well as the difference between liquid and headspace SPME were studied. An optimum SPME method was developed. Finally a more recent sample preparation technique, namely SBSE was evaluated to extract whisky volatiles.

  17. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  18. Fabric phase sorptive extraction: Two practical sample pretreatment techniques for brominated flame retardants in water.

    PubMed

    Huang, Guiqi; Dong, Sheying; Zhang, Mengfei; Zhang, Haihan; Huang, Tinglin

    2016-09-15

    Sample pretreatment is the critical section for residue monitoring of hazardous pollutants. In this paper, using the cellulose fabric as host matrix, three extraction sorbents such as poly (tetrahydrofuran) (PTHF), poly (ethylene glycol) (PEG) and poly (dimethyldiphenylsiloxane) (PDMDPS), were prepared on the surface of the cellulose fabric. Two practical extraction techniques including stir bar fabric phase sorptive extraction (stir bar-FPSE) and magnetic stir fabric phase sorptive extraction (magnetic stir-FPSE) have been designed, which allow stirring of fabric phase sorbent during the whole extraction process. In the meantime, three brominated flame retardants (BFRs) [tetrabromobisphenol A (TBBPA), tetrabromobisphenol A bisallylether (TBBPA-BAE), tetrabromobisphenol A bis(2,3-dibromopropyl)ether (TBBPA-BDBPE)] in the water sample were selected as model analytes for the practical evaluation of the proposed two techniques using high-performance liquid chromatography (HPLC). Moreover, various experimental conditions affecting extraction process such as the type of fabric phase, extraction time, the amount of salt and elution conditions were also investigated. Due to the large sorbent loading capacity and unique stirring performance, both techniques possessed high extraction capability and fast extraction equilibrium. Under the optimized conditions, high recoveries (90-99%) and low limits of detection (LODs) (0.01-0.05 μg L(-1)) were achieved. In addition, the reproducibility was obtained by evaluating the intraday and interday precisions with relative standard deviations (RSDs) less than 5.1% and 6.8%, respectively. The results indicated that two pretreatment techniques were promising and practical for monitoring of hazardous pollutants in the water sample. Due to low solvent consumption and high repeated use performance, proposed techniques also could meet green analytical criteria.

  19. Role of biofilms in sorptive removal of steroidal hormones and 4-nonylphenol compounds from streams

    USGS Publications Warehouse

    Writer, J.H.; Ryan, J.N.; Barber, L.B.

    2011-01-01

    Stream biofilms play an important role in geochemical processing of organic matter and nutrients, however, the significance of this matrix in sorbing trace organic contaminants is less understood. This study focused on the role of stream biofilms in sorbing steroidal hormones and 4-nonylphenol compounds from surface waters using biofilms colonized in situ on artificial substrata and subsequently transferred to the laboratory for controlled batch sorption experiments. Steroidal hormones and 4-nonylphenol compounds readily sorb to stream biofilms as indicated by organic matter partition coefficients (K om, L kg-1) for 17??-estradiol (102.5-2.8 L kg-1), 17??-ethynylestradiol (102.5-2.9 L kg -1), 4-nonylphenol (103.4-4.6 L kg-1), 4-nonylphenolmonoethoxylate (103.5-4.0 L kg-1), and 4-nonylphenoldiethoxylate (103.9-4.3 L kg-1). Experiments using water quality differences to induce changes in the relative composition of periphyton and heterotrophic bacteria in the stream biofilm did not significantly affect the sorptive properties of the stream biofilm, providing additional evidence that stream biofilms will sorb trace organic compounds under of variety of environmental conditions. Because sorption of the target compounds to stream biofilms was linearly correlated with organic matter content, hydrophobic partition into organic matter appears to be the dominant mechanism. An analysis of 17??-estradiol and 4-nonylphenol hydrophobic partition into water, biofilm, sediment, and dissolved organic matter matrices at mass/volume ratios typical of smaller rivers showed that the relative importance of the stream biofilm as a sorptive matrix was comparable to bed sediments. Therefore, stream biofilms play a primary role in attenuating these compounds in surface waters. Because the stream biofilm represents the base of the stream ecosystem, accumulation of steroidal hormones and 4-nonylphenol compounds in the stream biofilm may be an exposure pathway for organisms in higher trophic

  20. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  1. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    PubMed

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  2. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    PubMed Central

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  3. Bracing and Taping Techniques and Patellofemoral Pain Syndrome

    PubMed Central

    Jessee, April D.; Gourley, Meganne M.; Valovich McLeod, Tamara C.

    2012-01-01

    Reference/Citation: D'hondt NE, Struijs PA, Kerkhoffs GM, et al. Orthotic devices for treating patellofemoral pain syndrome. Cochrane Database Syst Rev. 2002;(2):CD002267. Clinical Question: Is there an effective bracing or taping technique for treating patellofemoral pain? Data Sources: The authors searched the Cochrane Musculoskeletal Injuries Group specialized register (December 2001), the Cochrane Controlled Trials Register (2000, issue 2), MEDLINE (January 1966 to March 2000), EMBASE (January 1988 to March 2000), CINAHL (January 1982 to March 2000), and PEDro (up to March 2000) without language limitations. They also contacted relevant orthotic companies and searched the included reference lists of the retrieved articles. The search terms for MEDLINE were anterior knee pain, arthralgia, knee joint, patella, and patellofemoral pain. The search terms for EMBASE were brace, chondropathy, dynamic splint, knee, orthosis, orthotics, patella, patella chondromalacia, patellofemoral joint, randomized control trial, and strap. The search terms for CINAHL were anterior knee pain, brace, orthot, orthos, randomi, strap, tape, patell, and patellofemoral. In PEDro, the subsequent composite of search terms was therapy: manipulation, massage, mobilization, orthoses, splinting, stretching, strength training, taping; subdiscipline: musculoskeletal, orthopaedics, sports; method: clinical trial; problem: muscle weakness, pain, reduced joint compliance; body part: foot or ankle, lower leg or knee. Study Selection: All randomized and quasi-randomized trials comparing the effectiveness of knee or foot orthotics for treatment of patellofemoral pain syndrome were included. Any trials that described the use of orthotic devices in conjunction with operative treatment were excluded from this review. Using these inclusion criteria, 2 reviewers independently assessed the potentially eligible studies and resolved any disagreements through conversation and negotiation by a third reviewer

  4. Torsion Strain Effects on Critical Currents of Hts Superconducting Tapes

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Minervini, Joseph V.; Bromberg, Leslie

    2010-04-01

    A torsional twist strain effect on the critical current of a thin HTS tape has been found to be well described by a longitudinal strain model taking into account the internal shortening compressive strains accompanied with the tensile longitudinal strains due to a torsional twist. The critical current of a twisted tape is given by the integration of the critical current densities corresponding to the strain distribution over the tape cross-section using axial strain data of the tape. The model is supported with experimental results of YBCO and BSCCO-2223 tapes. It has been also found that torsional twisting effects on the critical currents of a tape composing of the conventional lapped-tape cable and the twisted stacked-tape cable are described by the same equation as that of a twisted single tape.

  5. Comparison of a disposable sorptive sampler with thermal desorption in a gas chromatographic inlet, or in a dedicated thermal desorber, to conventional stir bar sorptive extraction-thermal desorption for the determination of micropollutants in water.

    PubMed

    Wooding, Madelien; Rohwer, Egmont R; Naudé, Yvette

    2017-09-01

    The presence of micropollutants in the aquatic environment is a worldwide environmental concern. The diversity of micropollutants and the low concentration levels at which they may occur in the aquatic environment have greatly complicated the analysis and detection of these chemicals. Two sorptive extraction samplers and two thermal desorption methods for the detection of micropollutants in water were compared. A low-cost, disposable, in-house made sorptive extraction sampler was compared to SBSE using a commercial Twister sorptive sampler. Both samplers consisted of polydimethylsiloxane (PDMS) as a sorptive medium to concentrate micropollutants. Direct thermal desorption of the disposable samplers in the inlet of a GC was compared to conventional thermal desorption using a commercial thermal desorber system (TDS). Comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) was used for compound separation and identification. Ten micropollutants, representing a range of heterogeneous compounds, were selected to evaluate the performance of the methods. The in-house constructed sampler, with its associated benefits of low-cost and disposability, gave results comparable to commercial SBSE. Direct thermal desorption of the disposable sampler in the inlet of a GC eliminated the need for expensive consumable cryogenics and total analysis time was greatly reduced as a lengthy desorption temperature programme was not required. Limits of detection for the methods ranged from 0.0010 ng L(-1) to 0.19 ng L(-1). For most compounds, the mean (n = 3) recoveries ranged from 85% to 129% and the % relative standard deviation (% RSD) ranged from 1% to 58% with the majority of the analytes having a %RSD of less than 30%. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Nanotribological properties of novel lubricants for magnetic tapes.

    PubMed

    Palacio, Manuel; Bhushan, Bharat

    2009-07-01

    Two classes of novel lubricants, perfluoropolyethers (PFPE) and ionic liquids (ILs), were deposited on metal film magnetic tapes. The adhesive force and coefficient of friction of lubricated and unlubricated tapes were investigated at the nanoscale with an atomic force microscope (AFM) as a function of various humidity and temperature conditions. Microscale tests with a ball-on-flat tribometer were also performed in order to study the length-scale effects on friction. Wear at ultralow loads was simulated and the lubricant removal mechanism was investigated by monitoring the friction force, surface potential and contact resistance with the AFM. Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS) experiments were conducted to determine the chemical species that affect intermolecular bonding and as an aid in interpreting how the lubricant film tribological properties vary with the environmental conditions. Z-TETRAOL, one of the PFPEs, was found to exhibit the lowest adhesion and friction among the lubricant films studied. The ionic liquid 1,1'-(pentane-1,5-diyl)bis(3-hydroxyethyl-1H-imidazolium-1-yl) di[bis(trifluoromethanesulfonyl)imide)] exhibited comparable nanotribological properties with the PFPEs. This is attributed to the presence of hydroxyl groups at its chain ends, which can hydrogen bond with the surface similar to PFPEs.

  7. Ubiquitous Graphene Electronics on Scotch Tape

    NASA Astrophysics Data System (ADS)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  8. 3M Tape Manufacturing Division

    EPA Pesticide Factsheets

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  9. Using magnetic tape technology for data migration

    NASA Technical Reports Server (NTRS)

    Therrien, David; Cheung, Yim-Ling

    1993-01-01

    Magnetic tape and optical disk library units (jukeboxes) are satisfying the demand for high-capacity cost-effective storage. The choice between optical disk and magnetic tape technology must take into account the cost limitations as well as the performance and reliability requirements of the user environment. Library units require data management software in order to function in an automated and user-transparent way. The most common data management applications are backup and recovery, data migration, and archiving. The medium access patterns that these applications create will be described. Since the most user visible application is data migration, a queue simulator was developed to model its performance against a variety of library units. The major subject of this paper is the design and implementation of this simulator as well as some simulation results. The relative cost and reliability of magnetic tape versus optical disk library units is presented for completeness.

  10. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  11. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  12. Effects of Kinesio taping and Mcconnell taping on balance and walking speed of hemiplegia patients

    PubMed Central

    Choi, Yong-Kyu; Park, Young-Han; Lee, Jung-Ho

    2016-01-01

    [Purpose] The aim of this study was to evaluate the overlap effect of the PNF following the application of Kinesio taping and the McConnell taping, and also the impact of the taping application method on the balance and walking speed of the patients with stroke. [Subjects and Methods] Thirty-six patients who were diagnosed with hemiplegia due to stroke were selected as subjects of this study. They were randomly and evenly divided into experiment group 1 (Kinesio taping group), experiment group 2 (McConnell taping group), and the control group; each group had 12 patients. [Results] The Berg balance scale (BBS) was used to evaluate balance, and the ability in this study. A 10 m walking test (10MWT) was performed to measure the walking speed. Experiment group 1 showed a statistically significant improvement in balance and walking speed compared to experiment group 2, and the control group in week 4 and week 8. [Conclusion] Application of Kinesio taping had a more beneficial effect on the balance and walking speed than joint-fixation taping of the patients with stroke. PMID:27190448

  13. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  14. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  15. Elastic therapeutic tape: do they have the same material properties?

    PubMed

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-04-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex(®), ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight(®) 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young's modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young's modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape.

  16. Elastic therapeutic tape: do they have the same material properties?

    PubMed Central

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-01-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex®, ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight® 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young’s modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young’s modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape. PMID:27190472

  17. The effect of ankle taping on the ground reaction force in vertical jump performance.

    PubMed

    Koyama, Keiji; Kato, Tomoo; Yamauchi, Junichiro

    2014-05-01

    The purpose of this study was to investigate the effects of closed basket weave (CBW) ankle taping on the vertical ground reaction force during the contact phase before the take-off in vertical jump performance. We hypothesized that ankle taping would limit the capability for explosive force generation during the contact phase before the take-off in jump performance. Twelve healthy young men (age, 20.2 ± 1.3 years; height, 1.76 ± 0.05 m; body mass, 66.1 ± 6.1 kg; mean ± SD) performed a vertical jump performance on a force plate without (CON) or with ankle taping (CBW technique) of the right ankle joint. Vertical jump ability was assessed using 2 styles of vertical jump with no arm swing: a countermovement jump (CMJ) and squat jump (SJ). From the vertical ground reaction force (GRF), maximum jump height, vertical impulse (VI), rate of force development, maximum GRF (GRFmax), and time-series GRF (GRFts) during the contact phase before the take-off in jump performance were determined. Jump height was significantly lower for CBW (36.6 ± 6.6 cm) than CON (38.1 ± 6.7 cm) in CMJ, but not in SJ. Rate of force development and GRFts at 35, 40, 45, 50, 55, 60, and 65% of total time of the contact phase in jumping performance were also significantly smaller for CBW than CON in CMJ, but not in SJ. Conversely, VI and GRFmax were not significantly different between the groups in either jump condition. These results suggest that ankle taping impairs CMJ performance, because of a decreased ability to develop large force rapidly on the ground before the take-off.

  18. Numerical Investigation of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with V-Cut Twisted Tape Inserts

    PubMed Central

    Salman, Sami D.; Kadhum, Abdul Amir H.; Takriff, Mohd S.; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration. PMID:24078795

  19. Numerical investigation of heat transfer and friction factor characteristics in a circular tube fitted with V-cut twisted tape inserts.

    PubMed

    Salman, Sami D; Kadhum, Abdul Amir H; Takriff, Mohd S; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.

  20. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    PubMed

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value < 0.01) using repeated measure analyses of variance. For each dependent variable with a P-value < 0.01, repeated measures with pairwise comparisons and Bonferroni adjustment were conducted to compare the three taping conditions. MT induced a significant reduction in anterior and posterior hip forces, knee flexion angular velocity, knee extensor moments, and hip flexion and extension moments compared with NT and KT (P = 0.001). There was no difference in hip or knee, kinematics or kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT.

  1. Role of biofilms in sorptive removal of steroidal hormones and 4-nonylphenol compounds from streams

    USGS Publications Warehouse

    Writer, Jeffrey H.; Ryan, Joseph N.; Barber, Larry B.

    2011-01-01

    Stream biofilms play an important role in geochemical processing of organic matter and nutrients, however, the significance of this matrix in sorbing trace organic contaminants is less understood. This study focused on the role of stream biofilms in sorbing steroidal hormones and 4-nonylphenol compounds from surface waters using biofilms colonized in situ on artificial substrata and subsequently transferred to the laboratory for controlled batch sorption experiments. Steroidal hormones and 4-nonylphenol compounds readily sorb to stream biofilms as indicated by organic matter partition coefficients (Kom, L kg–1) for 17β-estradiol (102.5–2.8 L kg–1), 17α-ethynylestradiol (102.5–2.9 L kg–1), 4-nonylphenol (103.4–4.6 L kg–1), 4-nonylphenolmonoethoxylate (103.5–4.0 L kg–1), and 4-nonylphenoldiethoxylate (103.9–4.3 L kg–1). Experiments using water quality differences to induce changes in the relative composition of periphyton and heterotrophic bacteria in the stream biofilm did not significantly affect the sorptive properties of the stream biofilm, providing additional evidence that stream biofilms will sorb trace organic compounds under of variety of environmental conditions. Because sorption of the target compounds to stream biofilms was linearly correlated with organic matter content, hydrophobic partition into organic matter appears to be the dominant mechanism. An analysis of 17β-estradiol and 4-nonylphenol hydrophobic partition into water, biofilm, sediment, and dissolved organic matter matrices at mass/volume ratios typical of smaller rivers showed that the relative importance of the stream biofilm as a sorptive matrix was comparable to bed sediments. Therefore, stream biofilms play a primary role in attenuating these compounds in surface waters. Because the stream biofilm represents the base of the stream ecosystem, accumulation of steroidal hormones and 4-nonylphenol compounds in the stream biofilm may be an exposure pathway for

  2. An Inexpensive, Easy to Build Slide-Tape Programmer

    ERIC Educational Resources Information Center

    Lukas, Terrence

    1975-01-01

    This article discusses the construction and use of a slide/tape programer that is simple to build and use, costs a fraction of the cheapest commercial models, and can be used with any tape recorder/player. (Author)

  3. FGGE/SMMR-30 tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/SMMR-30 tape which contains sea ice concentration data in 30 km resolution which are extracted and reformatted from Nimbus-7 SMMR PARM-30 tapes in accordance with the FGGE level II International Exchange Format Specification is outlined. There are three types of files on a FGGE/SMMR-30 tape. The first file on the tape is a test file. The second file on the tape is a tape header file. The remaining one or more files are data files. All files are terminated with a single end of file (EOP) tape mark. The last file is terminated with two EOF tape marks. All files are made up of one or more physical records. Each physical record contains 2960 bytes. Each data file contains all available values for a 6 hour synoptic time period.

  4. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  5. A Tape-Lecture Course in Electrochemistry.

    ERIC Educational Resources Information Center

    Sheridan, P.

    1978-01-01

    Investigates the possibility of using audio-tapes for self-study courses in technical colleges. This article presents: (1) description of the electrochemistry course taught; (2) results of the assessment of student reaction to the course; and (3) conclusions. (HM)

  6. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  7. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  8. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game,…

  9. Tape-Drive Based Plasma Mirror

    SciTech Connect

    Sokollik, T.; Leemans, W. P.; Shiraishi, S.; Osterhoff, J.; Evans, E.; Gonsalves, A. J.; Nakamura, K.; van Tilborg, J.; Lin, C.; Toth, C.

    2010-11-04

    We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots.

  10. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  11. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  12. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  13. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  14. Red Tape: Its Origins, Uses, and Abuses.

    ERIC Educational Resources Information Center

    Kaufman, Herbert

    Red tape, particularly with reference to administration in the federal government, is described, and suggestions that have been proposed for improvement are explored. Among the frustrations that are met in dealing with government are duplicative and contradictory requirements of different agencies, restrictions imposed for announced ends that are…

  15. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  16. Tape Recording and the End Product.

    ERIC Educational Resources Information Center

    England, A. W.

    1970-01-01

    Intended to provide intense and immediate classroom experiences, tape recording projects of students can take several different forms: (1) unscripted plays and improvised situations (e.g., such "biographies" as "The Life of Charlie MacHerckumdingle: An Awkward Cuss"); (2) plays based on stories or poems (e.g., dramatizations of episodes from "The…

  17. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  18. Directory of Federal Agency Education Data Tapes.

    ERIC Educational Resources Information Center

    Feller, Barbara A.

    This directory is the initial result of a Congressional mandate to the National Center for Education Statistics (NCES) to improve coordination among Federal agencies concerned with the collection and use of education data. It identifies and describes education data bases, predominantly quantitiative, available on computer tape from Federal…

  19. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  20. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  1. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  2. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  3. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  4. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  5. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  6. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape...

  7. The Feasibility of Using Taped Lectures to Replace Class Attendance.

    ERIC Educational Resources Information Center

    Menne, John W.; And Others

    The students in an introductory college psychology course were given the option of attending live lectures (control group) or listening to audio-taped lectures (experimental group). Each experimental subject was issued a tape recorder, a set of lecture tapes, and a schedule of lecture topics as presented to the control group. Conducted in the fall…

  8. Full tape thickness feature conductors for EMI structures

    DOEpatents

    Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.; Barner, Gregory

    2014-06-10

    Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.

  9. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  10. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical magnetic tape recorder. 870.2800 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800 Medical magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record and...

  11. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    design and fabrication problems that developed in the 140-foot telescope project. These had to be renegotiated with the NSF, honing skills that Jerry had already developed. In the course of this, he also made an effort to reach out and understand the astronomical community and to mend some of the rifts that accompanied the NSF's first venture into "big science." This all changed in 1963 when President Kennedy asked Leland Haworth to become the Director of the National Science Foundation and also asked Gerald Tape to take on Haworth's role as an Atomic Energy Commissioner working under the Chairmanship of Glenn Seaborg. All five Commissioners participated in all official actions of the body, but each one had special areas of concentration of effort. With some overlap, this assured fuller and deeper coverage of the broad spectrum of issues they faced. Jerry's special interests were nuclear weapons development; research in the physical, biological, and life sciences; and international cooperation. This menu was a broad one, and for six years of full-time effort it required endless travel to laboratories, conferences, and government-to-government meetings. International delegations involved civil as well as defense programs. Formal civil exchange programs were negotiated with many nations including the USSR. Negotiations on arms control issues involved contacts with the International Atomic Energy Agency (IAEA) and Atoms for Peace conferences. In the national research program area, Jerry became the lead Commissioner for the establishment of what became the Fermi Laboratory and its management organization, Universities Research Association (URA). Fermi Lab soon became, and still is, the primary United States high-energy particle physics institution. In 1969, Jerry Tape returned to AUI as president where he was welcomed enthusiastically. Both BNL and NRAO had grown and were thriving. Plans were being formulated for major new facilities, a proton collider with superconducting

  12. Effects of balance taping using kinesiology tape in a patient with moderate hallux valgus

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    Abstract Background: Hallux valgus, an increased angle of lateral deviation in the big toe, can cause pain and difficulties in balancing and walking. This study aimed to investigate the effects of balance taping using elastic therapeutic tape on moderate hallux valgus. Methods: When she walked with shoes, she complained of pain over the medial eminence of the hallux metatarsophalangeal (MTP) joint. Balance taping using kinesiology tape was applied for 3 months (average, 16hours/d) to both big toes of a 26-year-old woman with moderate hallux valgus. Results: On the right side, the hallux valgus angle (HVA) decreased from 21° to 14° and the intermetatarsal angle (IMA) decreased from 15° to 14.5°. On the left side, the HVA decreased from 22° to 11° and the IMA decreased from 15° to 12°. Furthermore, the patient was able to walk long distances in shoes without pain in the medial eminence of the hallux metatarsophalangeal joint. Conclusion: This study suggested that repeated balance taping with kinesiology tape could be used as a complementary treatment method for moderate hallux valgus. PMID:27861365

  13. Effects of Tape and Exercise on Dynamic Ankle Inversion

    PubMed Central

    Ricard, Mark D.; Sherwood, Stephen M.; Schulthies, Shane S.; Knight, Kenneth L.

    2000-01-01

    Objective: To compare the effects of tape, with and without prewrap, on dynamic ankle inversion before and after exercise. Design and Setting: Doubly multivariate analyses of variance were used to compare the taping and exercise conditions. Subjects were randomly assigned to a fixed treatment order as determined by a balanced latin square. The independent variables were tape application (no tape, tape with prewrap, tape to skin) and exercise (before and after). The dependent variables were average inversion velocity, total inversion, maximum inversion velocity, and time to maximum inversion. Subjects: Thirty college-age male and female students (17 males, 13 females; mean age = 24.9 ± 4.3 years, range, 19 to 39 years) were tested. Subjects were excluded from the study if they exhibited a painful gait or painful range of motion or had a past history of ankle surgery or an ankle sprain within the past 4 weeks. Measurements: We collected data using electronic goniometers while subjects balanced on the right leg on an inversion platform tilted about the medial-lateral axis to produce 15° of plantar flexion. Sudden ankle inversion was induced by pulling the inversion platform support, allowing the platform support base to rotate 37°. Ten satisfactory trials were recorded on the inversion platform before and after a prescribed exercise bout. We calculated total inversion, time to maximum inversion, average inversion velocity, and maximum inversion velocity after sudden inversion. Results: We found no significant differences between taping to the skin and taping over prewrap for any of the variables measured. There were significant differences between both taping conditions and no-tape postexercise for average inversion velocity, maximum inversion, maximum inversion velocity, and time to maximum inversion. The total inversion mean for no-tape postexercise was 38.8° ± 6.3°, whereas the means for tape and skin and for tape and prewrap were 28.3° ± 4.6° and 29.1°

  14. Sorptivity of rocks and soils of the van Genuchten-Mualem type

    SciTech Connect

    Zimmerman, R.W.; Bodvarsson, G.S.

    1991-06-01

    One hydrological process that will have great relevance to the performance of the proposed underground radioactive waste repository at Yucca Mountain, Nevada, is that of the absorption of water from a water-filled fracture into the adjacent unsaturated rock formation. The rate at which water is imbibed by a rock depends on the hydrological properties of the rock and on the initial saturation (or initial capillary suction) of the formation. The hydrological properties that affect imbibition are the relative permeability function and the capillary pressure function. These functions are often collectively referred to as the `characteristic functions` of the porous medium. For one-dimensional absorption, it can be shown that, regardless of the details of the characteristic functions, the total amount of water imbibed by the formation, per unit surface area, will be proportional to the square root of the elapsed time. Hence the ability of a rock or soil to imbibe water can be quantified by a parameter known as the sorptivity S, which is defined such that the cumulative volumetric liquid influx per unit area is given by Q = S{radical}t. The paper discusses the simplification of these characteristic functions of porous medium.

  15. Longitudinal Mechano-Sorptive Creep Behavior of Chinese Fir in Tension during Moisture Adsorption Processes

    PubMed Central

    Peng, Hui; Lu, Jianxiong; Jiang, Jiali; Cao, Jinzhen

    2017-01-01

    To provide comprehensive data on creep behaviors at relative humidity (RH) isohume conditions and find the basic characteristics of mechano-sorptive (MS) creep (MSC), the tensile creep behaviors, “viscoelastic creep (VEC)” at equilibrium moisture content and MSC during adsorption process, were performed on Chinese fir in the longitudinal direction under 20%, 40%, 60% and 80% RH (25 °C) and at 1, 1.3, and 1.6 MPa, respectively. The free swelling behavior was also measured, where the climate conditions corresponded with MSC tests. Based on the databases of free swelling, VEC, and MSC, the existence of MS effect was examined, and the application of the rheological model under the assumption of partitioned strain was investigated. The results revealed that both VEC and MSC increased with magnitude of applied stress, and the increasing RH level. Under all RH isohume conditions, the total strain of MSC was greater than that of VEC. The influence of RH level on VEC was attributed to the water plasticization effect, whereas that on MSC was presumed to be the effect of water plasticization and unstable state in the wood cell wall. In addition, the RH level promoted the relaxation behavior in MSC, while it slightly affected the relaxation behavior in VEC. In the future, the rheological model could consider the link between load configuration and the anatomic structural feature of wood. PMID:28796174

  16. Longitudinal Mechano-Sorptive Creep Behavior of Chinese Fir in Tension during Moisture Adsorption Processes.

    PubMed

    Peng, Hui; Lu, Jianxiong; Jiang, Jiali; Cao, Jinzhen

    2017-08-10

    To provide comprehensive data on creep behaviors at relative humidity (RH) isohume conditions and find the basic characteristics of mechano-sorptive (MS) creep (MSC), the tensile creep behaviors, "viscoelastic creep (VEC)" at equilibrium moisture content and MSC during adsorption process, were performed on Chinese fir in the longitudinal direction under 20%, 40%, 60% and 80% RH (25 °C) and at 1, 1.3, and 1.6 MPa, respectively. The free swelling behavior was also measured, where the climate conditions corresponded with MSC tests. Based on the databases of free swelling, VEC, and MSC, the existence of MS effect was examined, and the application of the rheological model under the assumption of partitioned strain was investigated. The results revealed that both VEC and MSC increased with magnitude of applied stress, and the increasing RH level. Under all RH isohume conditions, the total strain of MSC was greater than that of VEC. The influence of RH level on VEC was attributed to the water plasticization effect, whereas that on MSC was presumed to be the effect of water plasticization and unstable state in the wood cell wall. In addition, the RH level promoted the relaxation behavior in MSC, while it slightly affected the relaxation behavior in VEC. In the future, the rheological model could consider the link between load configuration and the anatomic structural feature of wood.

  17. Stir bar sorptive extraction applied to the determination of dicarboximide fungicides in wine.

    PubMed

    Sandra, P; Tienpont, B; Vercammen, J; Tredoux, A; Sandra, T; David, F

    2001-08-31

    The dicarboximide fungicides vinclozolin, iprodione and procymidone were analyzed in white wines using stir bar sorptive extraction (SBSE) in combination with thermal desorption-capillary GC-MS analysis (TD-cGC-MS). The method was optimized using spiked water samples in a concentration range between 0.5 and 100 microg/l. Iprodione was measured as its degradation product 3,5-dichlorophenyl hydantoin. Limits of quantification in the full scan MS mode are 0.5 microg/l for vinclozolin and procymidone and 5 microg/l for iprodione. In the ion monitoring mode, concentrations 100 times lower can be dosed. Because of wine matrix effects on the recoveries, quantification of the target fungicides in wine had to be carried out by standard addition. For the thermolabile iprodione, the accuracy of SBSE-TD-cGC-MS was verified using SBSE followed by liquid desorption and analysis by liquid chromatography-atmospheric pressure chemical ionization mass spectroscopy. Procymidone and iprodione were detected in wines in concentrations up to 65 microg/l while the highest concentration of vinclozolin detected was smaller than 3 microg/l.

  18. Stir bar sorptive extraction-thermal desorption-capillary GC-MS applied to biological fluids.

    PubMed

    Tienpont, B; David, F; Desmet, K; Sandra, P

    2002-05-01

    A new sample preparation method, stir bar sorptive extraction (SBSE), has been evaluated for the enrichment of organic solutes from biological fluids such as urine and blood. In SBSE, a stir bar coated with a polydimethylsiloxane layer is stirred for a given time in the sample. After sampling the stir bar is placed in a thermal desorption unit coupled on-line to capillary gas chromatography-mass spectrometry (SBSE-TD-CGC-MS). The principle and operation of SBSE are presented. Total profiling and target compound analysis have been selected as applications to illustrate the performance of SBSE-TD-CGC-MS (MSD). It is demonstrated that a variety analytes ranging from biological markers (phenols, hormones, fatty acids) to artificial contaminants (recreational drugs, plasticizers) can be enriched with high sensitivity. For polar solutes, in-situ derivatization can enhance both recovery into the polydimethylsiloxane (PDMS) layer and chromatographic analysis. Two types of derivatization have been applied, derivatization with ethyl chloroformate and with acetic acid anhydride. Linearity, detectability, and repeatability are illustrated by the determination of 1-hydroxypyrene in a urine sample from a smoker.

  19. A Permeability Model for Coal and Other Fractured, Sorptive-Elastic Media

    SciTech Connect

    Eric P. Robertson; Richard L. Christiansen

    2006-10-01

    This paper describes the derivation of a new equation that can be used to model the permeability behavior of a fractured, sorptive-elastic media, such as coal, under variable stress conditions commonly used during measurement of permeability data in the laboratory. The model is derived for cubic geometry under biaxial or hydrostatic confining pressures. The model is also designed to handle changes in permeability caused by adsorption and desorption of gases from the matrix blocks. The model equations can be used to calculate permeability changes caused by the production of methane from coal as well as the injection of gases, such as carbon dioxide, for sequestration in coal. Sensitivity analysis of the model found that each of the input variables can have a significant impact on the outcome of the permeability forecast as a function of changing pore pressure; thus, accurate input data are essential. The permeability model can also be used as a tool to determine input parameters for field simulations by curve-fitting laboratory-generated permeability data. The new model is compared to two other widely used coal permeability models using a hypothetical coal with average properties.

  20. Non-destructive method to determine halophenols and haloanisoles in cork stoppers by headspace sorptive extraction.

    PubMed

    Lorenzo, Cándida; Zalacain, Amaya; Alonso, Gonzalo L; Salinas, M A Rosario

    2006-05-12

    The new solvent-free technique called headspace sorptive extraction (HSSE) was used to determine 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, 2,4,6-trichloroanisole, 2,3,4,6-tetrachloroanisole, 2,4,6-tribromoanisole, pentachloroanisole in cork stoppers, without grinding them, as these may be responsible for the cork taint off-flavour in wine. The best HSSE sorption kinetics for the target analytes were obtained after submitting the spiked corks to 100 degrees C for 1h, followed by a 30 min stabilization time at room temperature. The stir bar was desorbed in a thermal desorption system coupled to a gas chromatograph-mass spectrometer. The method proposed showed good linearity over the concentration range tested, 1-70 ngg(-1), and correlation coefficients ranged from 0.90 to 0.99 for all the analytes. The reproducibility and repeatability of the method were estimated between 4.91 and 12.67%. The effect of the different cork matrixes on the extraction recovery of the target compounds was studied, with the natural corks showing the higher recovery percentage in relation to agglomerate ones.

  1. Stirring bar sorptive extraction in the determination of PAHs in drinking waters.

    PubMed

    García-Falcón, M S; Cancho-Grande, B; Simal-Gándara, J

    2004-04-01

    The application of a new extraction technique which is known as stir bar sorptive extraction (SBSE), followed by high-performance liquid chromatography with a fluorescence detector, was assessed for determining eight polycyclic aromatic hydrocarbons (PAHs) in water samples. The extraction conditions such as acetonitrile addition; effects of temperature and salt; and finally, extraction and desorption time profiles were studied. Once SBSE was optimized, analytical method parameters such as linearity (r(2)>0.991), precision (<9%), detection (0.5-7.3 ng/L) and quantitation (1.0-22 ng/L) limits were estimated. To correct for the 43-57% absolute recovery depending on the PAH, calibration was done with a line obtained submitting standard-spiked blank tap waters to the complete sample treatment and analysis. Consequently, relative recovery was about 100% because all water samples (those for calibration purposes and those for recovery estimation) were processed in the same way and the absolute recovery remained constant. SBSE method characteristics were checked with the analysis of real drinking waters in the search for PAHs.

  2. A permeability model for coal and other fractured, sorptive-elastic media

    SciTech Connect

    Robertson, E.P.; Christiansen, R.L.

    2008-09-15

    This paper describes the derivation of a new equation that can be used to model the permeability behavior of a fractured, sorptive-elastic medium, such as coal, under variable stress conditions. The equation is applicable to confinement pressure schemes commonly used during the collection of permeability data in the laboratory. The model is derived for cubic geometry under biaxial or hydrostatic confining pressures. The model is designed to handle changes in permeability caused by adsorption and desorption of gases onto and from the matrix blocks in fractured media. The model equations can be used to calculate permeability changes caused by the production of methane (CH{sub 4}) from coal as well as the injection of gases, such as carbon dioxide, for sequestration in coal. Sensitivity analysis of the model found that each of the input variables can have a significant impact on the outcome of the permeability forecast as a function of changing pore pressure, thus, accurate input data are essential. The permeability model also can be used as a tool to determine input parameters for field simulations by curve fitting laboratory-generated permeability data. The new model is compared to two other widely used coal-permeability models using a hypothetical coal with average properties.

  3. Sorptive uptake of selenium with magnetite and its supported materials onto activated carbon.

    PubMed

    Kwon, Jae H; Wilson, Lee D; Sammynaiken, R

    2015-11-01

    Kinetic and equilibrium uptake studies of selenite in aqueous solution with synthetic magnetite (Mag-P), commercial magnetite (Mag-C), goethite, activated carbon (AC), and a composite material containing 19% magnetite supported on activated carbon (CM-19) were investigated. Kinetic uptake studies used a one-pot setup at pH 5.26 at variable temperature. Sampling of unbound selenite in-situ was achieved with analytical detection by atomic absorbance. The sorptive uptake at equilibrium and kinetic conditions are listed in descending order: goethite>Mag-P>Mag-C>CM-19. Kinetic uptake parameters reveal that Mag-P showed apparent negative values for the activation energy (E(a)) and the enthalpy of activation (ΔH(‡)), in agreement with a multi-step process for the kinetic uptake of selenite. By contrast, Mag-C, CM-19, and goethite showed positive values for E(a) and ΔH(‡). The uptake properties of the various sorbent materials with selenite are in accordance with the formation of inner- and out-sphere complexes. Leaching of iron from the composite material (CM-19) was attenuated due to the stabilizing effect of the magnetite within the pore sites and the surface of AC. Supported iron oxide nanomaterial composites represent a unique sorbent material with tunable uptake properties toward inorganic selenite in aqueous solution.

  4. A Permeability Model for Coal and Other Fractured, Sorptive-Elastic Media

    SciTech Connect

    Eric P. Robertson; Richard L. Christiansen

    2008-09-01

    This paper describes the derivation of a new equation that can be used to model the permeability behavior of a fractured, sorptive-elastic medium, such as coal, under variable stress conditions. The equation is applicable to confinement pressure schemes commonly used during the collection of permeability data in the laboratory. The model is derived for cubic geometry under biaxial or hydrostatic confining pressures. The model is designed to handle changes in permeability caused by adsorption and desorption of gases onto and from the matrix blocks in fractured media. The model equations can be used to calculate permeability changes caused by the production of methane (CH4) from coal as well as the injection of gases, such as carbon dioxide, for sequestration in coal. Sensitivity analysis of the model found that each of the input variables can have a significant impact on the outcome of the permeability forecast as a function of changing pore pressure; thus, accurate input data are essential. The permeability model also can be used as a tool to determine input parameters for field simulations by curve fitting laboratory-generated permeability data. The new model is compared to two other widely used coal-permeability models using a hypothetical coal with average properties.

  5. Development and application of novel clonazepam molecularly imprinted coatings for stir bar sorptive extraction.

    PubMed

    Li, Xiaoxu; Mei, Xiaoliang; Xu, Lei; Shen, Xin; Zhu, Wanying; Hong, Junli; Zhou, Xuemin

    2016-04-15

    The molecularly imprinted magnetic stir bar coatings were created based on graft-functional Fe3O4 nanoparticles with magnetic field-induced self-assembly. The magnetic complex including clonazepam as template, the graft-functional Fe3O4 nanoparticles and methacrylic acid as monomers was pre-assembled through π-π interaction and hydrogen bonding, then was directionally adsorbed on the surface of magnetic stir bar under the magnetic induction. The molecularly imprinted coating with well-ordered structure was generated by one-step copolymerization based on the cross linking of ethylene glycol dimethacrylate. The molecularly imprinted coating with multiple recognition sites could be manufactured and applied in polar solvents, and showed superior selectivity and fast binding kinetics for benzodiazepines. The analytes in herbal health foods, treated by stir bar sorptive extraction, were determined by HPLC-UV. Good linearity was observed in the range of 0.01-2 μg mL(-1). The content of clonazepam in the herbal health foods was found to be 44 ng g(-1), and the average recoveries were 89.8-103.3% with a relative standard deviation (RSD) <6.5%, demonstrating the successful application in real sample analysis.

  6. Stir bar sorptive extraction for the analysis of short-chain chlorinated paraffins in water.

    PubMed

    Llorca-Porcel, Julio; Martínez-Soriano, Esther; Valor, Ignacio

    2009-05-01

    An optimised method using stir bar sorptive extraction (SBSE) and a thermal desorption-GC-electron capture detector (GC-ECD) for the determination of short-chain chlorinated paraffins from water samples was developed. Recoveries near to 100% were obtained by using 20 mm x 0.5 mm (length x film thickness) PDMS commercial stir bars from 200 mL spiked water samples and 20% methanol addition with an extraction period of 24 h. Method sensitivity, linearity and precision were evaluated for surface water and wastewater spiked samples. A LOD of 0.03 and 0.04 microg/L was calculated for surface and wastewater, respectively. The precision of the method given as an RSD was below 20% for both matrices. The developed method was applied for the analysis of two real samples from a contaminated river and a wastewater treatment plant. Results were in accordance with those obtained using a previously developed method based on solid phase microextraction (SPME).

  7. Automated multisyringe stir bar sorptive extraction using robust montmorillonite/epoxy-coated stir bars.

    PubMed

    Ghani, Milad; Saraji, Mohammad; Maya, Fernando; Cerdà, Víctor

    2016-05-06

    Herein we present a simple, rapid and low cost strategy for the preparation of robust stir bar coatings based on the combination of montmorillonite with epoxy resin. The composite stir bar was implemented in a novel automated multisyringe stir bar sorptive extraction system (MS-SBSE), and applied to the extraction of four chlorophenols (4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol) as model compounds, followed by high performance liquid chromatography-diode array detection. The different experimental parameters of the MS-SBSE, such as sample volume, selection of the desorption solvent, desorption volume, desorption time, sample solution pH, salt effect and extraction time were studied. Under the optimum conditions, the detection limits were between 0.02 and 0.34μgL(-1). Relative standard deviations (RSD) of the method for the analytes at 10μgL(-1) concentration level ranged from 3.5% to 4.1% (as intra-day RSD) and from 3.9% to 4.3% (as inter-day RSD at 50μgL(-1) concentration level). Batch-to-batch reproducibility for three different stir bars was 4.6-5.1%. The enrichment factors were between 30 and 49. In order to investigate the capability of the developed technique for real sample analysis, well water, wastewater and leachates from a solid waste treatment plant were satisfactorily analyzed.

  8. Headspace sorptive extraction and GC-TOFMS for the identification of volatile fungal metabolites.

    PubMed

    Wihlborg, Rachel; Pippitt, David; Marsili, Ray

    2008-10-01

    Volatiles from fungi cultivated in Petri dishes were collected by a simple headspace polydimethylsiloxane (PDMS) sorptive extraction technique (HSSE), thermally desorbed into a gas chromatographic capillary column and detected and identified by gas chromatography-time-of-flight mass spectrometry (GC-TOFMS). The method was used to compare metabolite profiles of seven species of fungi grown on two types of sterile agars - potato dextrose and Sabouraud dextrose. Three species from the genus Penicillium (P. italicum, P. camemberti, and P. roqueforti) and four outgroups, each from a different phylum (Saprolegnia sp.; Sordaria fimicola, wild-type; Coprinus cinereus; and Rhizopus stolonifer) were grown on the two types of agars and analyzed. Multivariate analysis (PCA) was used to determine whether separate classes of fungi can be distinguished from one another based on their metabolite profiles. PCA showed clear class separation between the three Penicillium samples and the outgroups. Slight differences were observed in metabolite profiles as a function of growth medium. HSSE/GC-TOFMS appears to be a relatively simple and accurate technique for classification of fungi based on their volatile metabolite profiles. The volatiles sampling technique reported here is non-destructive, so it can be applied with traditional methods for studying fungal growth and metabolism.

  9. Quantitative analysis of perfumes in talcum powder by using headspace sorptive extraction.

    PubMed

    Ng, Khim Hui; Heng, Audrey; Osborne, Murray

    2012-03-01

    Quantitative analysis of perfume dosage in talcum powder has been a challenge due to interference of the matrix and has so far not been widely reported. In this study, headspace sorptive extraction (HSSE) was validated as a solventless sample preparation method for the extraction and enrichment of perfume raw materials from talcum powder. Sample enrichment is performed on a thick film of poly(dimethylsiloxane) (PDMS) coated onto a magnetic stir bar incorporated in a glass jacket. Sampling is done by placing the PDMS stir bar in the headspace vial by using a holder. The stir bar is then thermally desorbed online with capillary gas chromatography-mass spectrometry. The HSSE method is based on the same principles as headspace solid-phase microextraction (HS-SPME). Nevertheless, a relatively larger amount of extracting phase is coated on the stir bar as compared to SPME. Sample amount and extraction time were optimized in this study. The method has shown good repeatability (with relative standard deviation no higher than 12.5%) and excellent linearity with correlation coefficients above 0.99 for all analytes. The method was also successfully applied in the quantitative analysis of talcum powder spiked with perfume at different dosages.

  10. Optimization of stir bar sorptive extraction applied to the determination of odorous compounds in drinking water.

    PubMed

    Benanou, D; Acobas, F; de Roubin, M R

    2004-01-01

    The off-flavour compounds 2-methylisoborneol (MIB), geosmin, 2,4,6-trichloroanisole, 2,3,6-trichloroanisole, 2,3,4-trichloroanisole and 2,4,6-tribromoanisole were analyzed in water samples by Stir Bar Sorptive Extraction (SBSE) followed by on-line thermal desorption (TD)-capillary GC/MS. Quantification was performed using MS in the single ion monitoring mode (SIM) with 2,4,6-trichloroanisol-D5 as internal standard. Quantification limits are 0.1 ng/l to 0.2 ng/l for the haloanisoles, 0.5 ng/l for geosmin and 1 ng/l for MIB. The relative standard deviations at the quantification limit are ranging from 7 to 14.6%. SBSE-recovery was evaluated by spiking real water samples and varied from 87 to 117%. More than twenty samples per day can be analyzed by SBSE-TD-capillary GC-MS. The same technique in combination with olfactometry was used to elucidate unknown odorous compounds in water samples.

  11. Suitability of polydimethylsiloxane rods for the headspace sorptive extraction of polybrominated diphenyl ethers from water samples.

    PubMed

    Montes, R; Rodríguez, I; Rubí, E; Cela, R

    2007-03-02

    The suitability of an inexpensive polydimethysiloxane (PDMS) sorbent, produced on an industrial scale, for the extraction of polybrominated diphenyl ethers (PBDEs), from tetra- to hexabrominated congeners, from water samples was assessed. Experiments were carried out using samples spiked with a pentabromo diphenyl ether (pentaBDE) mixture, PDMS rods with a diameter of 2 mm and gas chromatography with micro-electron-capture detection (GC-micro-ECD). Influence of several variables on the efficiency of the enrichment step and the further desorption of the analytes was investigated in detail. The best performance was achieved in the headspace sorptive extraction (HSSE) mode, at 95 degrees C, using 80 mL water samples containing a 30% of sodium chloride. Extractions were performed overnight using disposable PDMS rods with a length of 10 mm (31 microL volume). Analytes were further recovered from the PDMS sorbent using just 1 mL of diethyl ether. This solvent was evaporated and extracts reconstituted with 25 microL of isooctane. Under final working conditions absolute extraction efficiencies from 69 to 93% and enrichment factors higher than 2200 folds were achieved for all species. The proposed method provided acceptable precisions (relative standard deviations values under 12%), correlation coefficients higher than 0.998 and the yield of the HSSE process remained constant for different water samples.

  12. Some factors determining the effective resistance between strands in flat cables (or superconducting filaments in tapes)

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2000-04-01

    Two effects are considered which can influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. As analogous cases, the one-layer Rutherford-type cable with classical superconductors and the tapes with twisted BSCCO filaments in a silver matrix in perpendicular magnetic fields are considered as a model. At first, the amount of the central core between the strands and the silver matrix between the filaments increases the effective conductance compared with the direct current paths, which is supposed to be proportional to the touching area of filaments. The increase factor is about two and can be easily suppressed by other effects, such as the contact resistance between the superconductor and the matrix. However, due to the strong anisotropy of critical parameters for high temperature superconductors, this effect can partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The second effect is connected with the existence of the induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of the filaments. This contribution is prevailing for the anisotropic superconductors. Therefore, to obtain low ac coupling losses in BSCCO tapes, structures with smaller filament number are required. This case is analogous to round structures, leading to ac losses proportional to the square of the layer number in the field direction.

  13. Telocyte's contacts.

    PubMed

    Faussone-Pellegrini, Maria-Simonetta; Gherghiceanu, Mihaela

    2016-07-01

    Telocytes (TC) are an interstitial cell type located in the connective tissue of many organs of humans and laboratory mammals. By means of homocellular contacts, TC build a scaffold whose meshes integrity and continuity are guaranteed by those contacts having a mechanical function; those contacts acting as sites of intercellular communication allow exchanging information and spreading signals. Heterocellular contacts between TC and a great variety of cell types give origin to mixed networks. TC, by means of all these types of contacts, their interaction with the extracellular matrix and their vicinity to nerve endings, are part of an integrated system playing tissue/organ-specific roles.

  14. Selection of an adhesive tape suitable for forensic fiber sampling.

    PubMed

    De Wael, Kris; Gason, Fabrice G C S J; Baes, Christiaan A V

    2008-01-01

    Five commercial adhesive tapes were tested for fiber uptake and saturation, for recovery and for ease of analysis. On the basis of the results, a high tack adhesive tape has been selected to be used for forensic fiber sampling. This adhesive tape is used as sampling material in two different micro trace kits. The first tape lifting kit is used mainly for the sampling of cars and the second is a 1:1 tape lifting kit for the collection of fibers on a corpse.

  15. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  16. Optimizing ankle performance when taped: Effects of kinesiology and athletic taping on proprioception in full weight-bearing stance.

    PubMed

    Long, Zhi; Wang, Renwei; Han, Jia; Waddington, Gordon; Adams, Roger; Anson, Judith

    2017-03-01

    To explore the effects of kinesiology taping (KT) and athletic taping (AT) on ankle proprioception when tested in functional, full weight-bearing stance. Cross-sectional study. Twenty-four healthy university students participated. Proprioception was measured using the Active Movement Extent Discrimination Apparatus (AMEDA). The three testing conditions: no-taping, KT, AT, and foot tested were randomly assigned. Perceived comfort, support and proprioceptive performance under two taping conditions were recorded. Proprioceptive discrimination scores with 95% CIs for no-taping, KT and AT were 0.81 (0.79-0.84), 0.81 (0.79-0.83), and 0.79 (0.77-0.81). Repeated measures ANOVA showed neither any significant difference associated with taping compared with no-taping (p=0.30), nor any difference between KT and AT (p=0.19). The group was then divided, according to their no-taping scores, into two sub-groups: with scores below the no-taping mean (n=13), and above the mean (n=11). ANOVA revealed a significant interaction (p=0.008) indicating that above-average no-taping performers proprioception scores were worse when taped, whereas below-average performers improved. For both KT and AT, only ratings of perceived comfort when taped were significantly associated with actual proprioceptive performance (both r>0.44, p≤0.03). Other perception ratings (support and performance) were significantly inter-correlated (both r>0.42, p<0.04), but neither was significantly correlated with actual performance (both p>0.31). Taping of the foot and ankle may amplify sensory input in a way that enhances proprioception of poor performers but produces an input overload that impairs proprioception in those who originally performed well when no-taping. Screening of ankle proprioception may identify those who would benefit most from taping. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

    NASA Technical Reports Server (NTRS)

    Wohl, Christopher; Palmieri, Frank L.; Forghani, Alireza; Hickmott, Curtis; Bedayat, Houman; Coxon, Brian; Poursartip, Anoush; Grimsley, Brian

    2017-01-01

    NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly

  18. Too tall for the tape: the weight of schoolchildren who do not fit the Broselow tape.

    PubMed

    Cattermole, G N; Leung, P Y M; Graham, C A; Rainer, T H

    2014-07-01

    In paediatric resuscitation, for a rapid and accurate estimate of children's weight, the Broselow tape can be used in children who are 46-144 cm tall. The Broselow tape has previously been found to provide the most accurate estimate of children's weight internationally, but it is not known how many fall outside the range of the tape, or whether such children can be assumed to be of adult weight, or how otherwise to estimate the weight of these children. To determine what proportion of children in different age groups falls outside the limits of the Broselow tape, how their weight compares with that of the adults and what correlates most strongly with weight in these children. This was a population-based prospective observational study of Chinese children up to 12 years old, from schools in Hong Kong. Weight was measured to the nearest 0.2 kg, and the height, foot-length and mid-arm circumference (MAC) were measured to the nearest 0.1 cm. 40% of 10-year olds and 70% of 11-year olds were too tall for the tape. Their median weight was 41.9 kg. This was significantly less than the median weight of 18-year olds (55 kg, p<0.0001) in Hong Kong. The strongest correlate with weight in these children was MAC. The Broselow tape is inappropriate for use in most children over 10 years old. Children too tall for the tape cannot be assumed to be of adult weight; to do so would imply an average overestimate of 30%. Weight estimates in older children could be based on MAC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Energy Data Base: output magnetic tape description

    SciTech Connect

    Busse, A.E.

    1982-06-01

    This document describes a format for disseminating bibliographic citations, abstracts and subject content indicators for energy information on computer readable magnetic tape issued after July 1976. The magnetic tapes contain information incorporated into the DOE data base. This base is used by TIC to generate multiple publications and to support information retrieval activities. Information, or data, pertinent to one bibliographic reference will be called an entry. The entries are logically composed of data elements (such as title, authors, etc.). This format supersedes a previous version, used since 1974, as described in Report TID-4581-R4. The format has been revised to permit incorporation of DOE/TIC bibliographic data encompassing the broader scope of information related to the development or use of energy resources.

  20. A sequential tape monitor for toluene diisocyanate.

    PubMed

    Rando, R J; Duvoisin, P F; Abdel-Kader, H; Hammad, Y Y

    1987-06-01

    An electronic microcircuit controller has been designed to convert a commercially available continuous tape monitor for toluene diisocyanate (TDI) into a sequential sampler in order to eliminate deficiencies in response and resolution of fluctuating TDI concentrations. The modified monitor will collect up to fourteen 12-min samples per work shift. The sensitivity of the monitor was doubled approximately by the inclusion of a blue filter in the optics of the reader unit. Recalibration of several modified monitors indicated a wide range in response to TDI necessitating individual calibrations. No significant difference in response to the 2,4 and 2,6 isomers of toluene diisocyanate was noted for modified personal monitors, in contrast to a 25% lower response to 2,6-TDI by an area monitor in which the same detection tape was used. The modified monitor has shown a reliability rate of about 90% during a three-year field survey of TDI exposures.

  1. Deployable Hexapod Using Tape-Springs

    DTIC Science & Technology

    2005-07-13

    main advantages of this concept compared to classical hyper-stable telescope structures are: - a reduced volume during launch allowing large systems...The main advantages of a deployable and active telescope structure compared to classical hyperstable telescope structures are a reduced volume...developed and manufactured by IWF TÜ Braunschweig who already applied them to motorised applications. The steel tape-spring can be rolled in the coiling

  2. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  3. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  4. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  5. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 2 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 5 through 7. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139357), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). On flight day 5, the transfer and installation of a Power and Data Grapple Fixture onto the P6 Truss during an EVA (extravehicular activity) is shown. The relocation of micrometeorite debris shields is also shown. Canadarm 2 is used to move the Mobile Base System near the Mobile Transporter on the ISS Destiny Module. The capture of the Mobile Base System takes place on flight day 6, along with a crew transfer ceremony on board the ISS. The video includes a view of the South Pacific just before dawn, and the Endeavour crew answers questions from the public.

  6. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  7. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2016-11-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  8. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2017-04-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  9. Current Distribution in Wide YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Carrera, M.; Granados, X.; Amorós, J.; Puig, T.; Obradors, X.

    The need of a better mechanical behaviour and the stabilization of coated conductors for applications, as Magnets, cables or Fault Current Limiters, has motivated the lamination of tapes with stainless steel or copper alloys, increasing so the elastic modulus of the conductors and their mechanical performance. Some of the stainless steels used are magnetic, thus introducing some perturbations of the current flow when energizing the conductor. In order to detect these possible perturbations, the magnetic self field in the surface of the tape has been explored by Hall mapping technique at several current loads in a monotonically driven cyclic sequence. By increasing current steps when loading up, crossing the critical field threshold, and decreasing down to remanent state. Deviation from the expected magnetic map has been observed. In this work, we will report on the resulting measurements, and the current flow is calculated by solving the inverse problem for a 12 mm wide stainless steel reinforced Coated Conductor tape. We discuss on the likely origin of the observed perturbations.

  10. Fabric phase sorptive extraction followed by UHPLC-MS/MS for the analysis of benzotriazole UV stabilizers in sewage samples.

    PubMed

    Montesdeoca-Esponda, Sarah; Sosa-Ferrera, Zoraida; Kabir, Abuzar; Furton, Kenneth G; Santana-Rodríguez, José Juan

    2015-10-01

    A fast and sensitive sample preparation strategy using fabric phase sorptive extraction followed by ultra-high-performance liquid chromatography and tandem mass spectrometry detection has been developed to analyse benzotriazole UV stabilizer compounds in aqueous samples. Benzotriazole UV stabilizer compounds are a group of compounds added to sunscreens and other personal care products which may present detrimental effects to aquatic ecosystems. Fabric phase sorptive extraction is a novel solvent minimized sample preparation approach that integrates the advantages of sol-gel derived hybrid inorganic-organic nanocomposite sorbents and the flexible, permeable and hydrophobic surface chemistry of polyester fabric. It is a highly sensitive, fast, efficient and inexpensive device that can be reused and does not suffer from coating damage, unlike SPME fibres or stir bars. In this paper, we optimized the extraction of seven benzotriazole UV filters evaluating the majority of the parameters involved in the extraction process, such as sorbent chemistry selection, extraction time, back-extraction solvent, back-extraction time and the impact of ionic strength. Under the optimized conditions, fabric phase sorptive extraction allows enrichment factors of 10 times with detection limits ranging from 6.01 to 60.7 ng L(-1) and intra- and inter-day % RSDs lower than 11 and 30 % for all compounds, respectively. The optimized sample preparation technique followed by ultra-high-performance liquid chromatography and tandem mass spectrometry detection was applied to determine the target analytes in sewage samples from wastewater treatment plants with different purification processes of Gran Canaria Island (Spain). Two UV stabilizer compounds were measured in ranges 17.0-60.5 ng mL(-1) (UV 328) and 69.3-99.2 ng mL(-1) (UV 360) in the three sewage water samples analysed.

  11. Vacuum-free laminated top electrode with conductive tapes for scalable manufacturing of efficient perovskite solar cells

    SciTech Connect

    Shao, Yuchuan; Wang, Qi; Dong, Qingfeng; Yuan, Yongbo; Huang, Jinsong

    2015-06-25

    The efficiency of organometal trihalide perovskites (OTP) solar cells have reached that parity of single crystal silicon, and its nature abundant raw material and solution-process capability promise a bright future for commercialization. However, the vacuum based techniques for metal electrode deposition and additional encapsulation layer increase the cost of the perovskite solar cells dramatically and impede their commercialization process. Here, we report a vacuum-free low temperature lamination technique to fabricate the top electrode by commercial conductive tapes (C-tape). The simple fabrication method yields good quality contact and high efficiency device of 12.7%. The C-tapes also encapsulated the devices effectively, resulting in greatly improved device stability. As a result, the combination of lamination of electrodes and encapsulation layers into a single step significantly reduce the cost of device fabrication.

  12. Vacuum-free laminated top electrode with conductive tapes for scalable manufacturing of efficient perovskite solar cells

    DOE PAGES

    Shao, Yuchuan; Wang, Qi; Dong, Qingfeng; ...

    2015-06-25

    The efficiency of organometal trihalide perovskites (OTP) solar cells have reached that parity of single crystal silicon, and its nature abundant raw material and solution-process capability promise a bright future for commercialization. However, the vacuum based techniques for metal electrode deposition and additional encapsulation layer increase the cost of the perovskite solar cells dramatically and impede their commercialization process. Here, we report a vacuum-free low temperature lamination technique to fabricate the top electrode by commercial conductive tapes (C-tape). The simple fabrication method yields good quality contact and high efficiency device of 12.7%. The C-tapes also encapsulated the devices effectively, resultingmore » in greatly improved device stability. As a result, the combination of lamination of electrodes and encapsulation layers into a single step significantly reduce the cost of device fabrication.« less

  13. Microwave characterization of normal and superconducting states of MOCVD made YBCO tapes

    NASA Astrophysics Data System (ADS)

    Wosik, Jarek; Krupka, Jerzy; Qin, Kuang; Ketharnath, Dhivya; Galstyan, Eduard; Selvamanickam, Venkat

    2017-03-01

    We have used a microwave, non-contact, non-destructive, dielectric resonator (DR) technique to characterize complex conductivity of different quality YBCO/Hastelloy tapes for the purpose of exploring such a technique as a potential quality control method for fabrication of YBCO tapes. The tapes were deposited at different temperatures on Hastelloy-supported oxide buffer layers using the MOCVD technique. The buffer stack consisted of aluminum oxide (Al2O3), yttrium oxide (Y2O3), and textured ion beam assisted deposition-MgO and LaMnO3 layers. Two dielectric resonators (DRs), the single post DR, consisting of high-permittivity barium zirconium titanate ceramic operating at 13 GHz in quasi-TE01δ mode, and the rod DR, consisting of rutile single crystal disk operating at 9.4 GHz in-TE011 mode, were designed to meet sensitivity requirements for characterization of conductivity of the superconductor at normal and superconducting states, respectively. For calculations of complex conductivity from experimental data of Q-factor and resonant frequency shift, a commercial electromagnetic simulator HFSS, based on finite elements analysis, was used. The theoretical Q-factor and resonant frequency on conductivity functions obtained from full wave numerical simulations of microwave fields were matched with the experimental data to determine conductivity of the YBCO tapes in both normal and superconducting states. In addition, for comparison purposes, 280 nm thick high-quality YBCO epitaxial film deposited on a dielectric substrate was also characterized, including frequency dependence of the complex conductivity. Discussion about feasibility of using DR microwave techniques as a quality control tool via measurements of conductivity versus temperature slope of the YBCO/Hastelloy tape in normal state is included. Also, microwave conductivity values of Hastelloy substrate as a function of temperature are reported.

  14. Biochar characteristics produced from food-processing products and their sorptive capacity for mercury and phenanthrene

    NASA Astrophysics Data System (ADS)

    Fotopoulou, Kalliopi N.; Karapanagioti, Hrissi K.; Manariotis, Ioannis D.

    2015-04-01

    Various organic-rich wastes including wood chips, animal manure, and crop residues have been used for biochar production. Biochar is used as an additive to soils to sequester carbon and improve soil fertility but its use as a sorbent for environmental remediation processes is gaining increased attention. Surface properties such as point of zero charge, surface area and pore volume, surface topography, surface functional groups and acid-base behavior are important factors, which affect sorption efficiency. Understanding the surface alteration of biochars increases our understanding of the pollutant-sorbent interaction. The scope of the present work was to evaluate the effect of key characteristics of biochars on their sorptive properties. Raw materials for biochar production were evaluated including byproducts from brewering, coffee, wine, and olive oil industry. The charring process was performed at different temperatures under limited-oxygen conditions using specialized containers. The surface area, the pore volume, and the average pore size of the biochars were determined. Open surface area and micropore volume were determined using t-plot method and Harkins & Jura equation. Raw food-processing waste demonstrates low surface area that increases by 1 order of magnitude by thermal treatment up to 750oC. At temperatures from 750 up to 900oC, pyrolysis results to biochars with surface areas 210-700 m2/g. For the same temperature range, a high percentage (46 to73%) of the pore volume of the biochars is due to micropores. Positive results were obtained when high surface area biochars were tested for their ability to remove organic (i.e. phenanthrene) and inorganic (i.e. mercury) compounds from aqueous solutions. All these properties point to new materials that can effectively be used for environmental remediation.

  15. Stir bar sorptive extraction of diclofenac from liquid formulations: a proof of concept study.

    PubMed

    Kole, Prashant Laxman; Millership, Jeff; McElnay, James C

    2011-03-25

    A new stir bar sorptive extraction (SBSE) technique coupled with HPLC-UV method for quantification of diclofenac in pharmaceutical formulations has been developed and validated as a proof of concept study. Commercially available polydimethylsiloxane stir bars (Twister™) were used for method development and SBSE extraction (pH, phase ratio, stirring speed, temperature, ionic strength and time) and liquid desorption (solvents, desorption method, stirring time etc) procedures were optimised. The method was validated as per ICH guidelines and was successfully applied for the estimation of diclofenac from three liquid formulations viz. Voltarol(®) Optha single dose eye drops, Voltarol(®) Ophtha multidose eye drops and Voltarol(®) ampoules. The developed method was found to be linear (r=0.9999) over 100-2000ng/ml concentration range with acceptable accuracy and precision (tested over three QC concentrations). The SBSE extraction recovery of the diclofenac was found to be 70% and the LOD and LOQ of the validated method were found to be 16.06 and 48.68ng/ml, respectively. Furthermore, a forced degradation study of a diclofenac formulation leading to the formation of structurally similar cyclic impurity (indolinone) was carried out. The developed extraction method showed comparable results to that of the reference method, i.e. method was capable of selectively extracting the indolinone and diclofenac from the liquid matrix. Data on inter and intra stir bar accuracy and precision further confirmed robustness of the method, supporting the multiple re-use of the stir bars. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Covalent immobilization of graphene onto stainless steel wire for jacket-free stir bar sorptive extraction.

    PubMed

    Zhang, Wenpeng; Zhang, Zixin; Zhang, Juan; Meng, Jiawei; Bao, Tao; Chen, Zilin

    2014-05-23

    Stainless steel wire is a good substrate for jacket-free stir bar sorptive extraction (SBSE). In this work, we present the first example of chemical modification of graphene on stainless steel wire (SSW) for SBSE. Bio-inspired polydopamine was firstly modified on the SSW covalently; then graphene oxide was introduced and reacted with amino groups of polydopamine layer. The modification of polydopamine and graphene can be repeated by a layer-by-layer strategy, resulting in control of the thickness of graphene layer and increase of extraction capability. The prepared covalently immobilized graphene-stainless steel wire (G-SSW) exhibited good stability under stirring, ultrasonication and treatment with commonly used organic solvents, basic and acidic solutions. Application as stir bar for SBSE, G-SSW was found to possess good extraction efficiency towards pollutant polyaromatic hydrocarbons (PAHs), with enrichment factors from 10086 to 16896. After optimization of conditions, G-SSW based SBSE was coupled HPLC for determination of PAHs in environmental and food samples. The quantitative method has low limits of detection of 0.2-50pg/mL, which is better than some reported SBSE-HPLC methods. The method shows wide linear range (200-5000, 10-1000 and 1-1000pg/mL), good linearity (r≥0.9950) and good reproducibility (RSD≤4.97%). The method has been applied to soil and food samples, with good selectivity and good recoveries ranging from 88.5-113.6%. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Relation between Soil Order and Sorptive Capacity for Dissolved Organic Carbon

    SciTech Connect

    Heal, Katherine R; Brandt, Craig C; Mayes, Melanie; Phillips, Jana Randolph; Jardine, Philip M

    2012-01-01

    Soils have historically been considered a temporary sink for organic C, but deeper soils may serve as longer term C sinks due to the sorption of dissolved organic C (DOC) onto Fe- and clay-rich mineral soil particles. This project provides an improved understanding and predictive capability of the physical and chemical properties of deep soils that control their sorptive capacities for DOC. Two hundred thirteen subsurface soil samples (72 series from five orders) were selected from the eastern and central United States. A characterized natural DOC source was added to the soils, and the Langmuir sorption equation was fitted to the observed data by adjusting the maximum DOC sorption capacity (Q{sub max}) and the binding coefficient (k). Different isotherm shapes were observed for Ultisols, Alfisols, and Mollisols due to statistically significant differences in the magnitude of k, while Q{sub max} was statistically invariant among these three orders. Linear regressions were performed on the entire database and as a function of soil order to correlate Langmuir fitted parameters with measured soil properties, e.g., pH, clay content, total organic C (TOC), and total Fe oxide content. Together, textural clay and Fe oxide content accounted for 35% of the variation in Q{sub max} in the database, and clay was most important for Alfisols and Ultisols. The TOC content, however, accounted for 27% of the variation in Q{sub max} in Mollisols. Soil pH accounted for 45% of the variation in k for the entire database, 41% for Mollisols, and 22% for Alfisols. Our findings demonstrate that correlations between Langmuir parameters and soil properties are different for different soil orders and that k is a more sensitive parameter for DOC sorption than is Q{sub max} for temperate soils from the central and eastern United States.

  18. New monolithic stir-cake-sorptive extraction for the determination of polar phenols by HPLC.

    PubMed

    Huang, Xiaojia; Wang, Yulei; Yuan, Dongxing; Li, Xiaojing; Nong, Shuyu

    2013-03-01

    A novel porous monolith has been prepared and used as a sorbent in stir-cake-sorptive extraction (SCSE). The monolithic material was prepared by in-situ copolymerization of allyl thiourea (AT) and divinylbenzene (DB) in the presence of dimethylformamide as a porogen solvent. To optimize the polymerization conditions, different monoliths with different ratios of functional monomer to porogenic solvent were prepared, and their extraction efficiency was investigated in detail. The monolith was characterized by elemental analysis, scanning electron microscopy, mercury intrusion porosimetry, and infrared spectroscopy. Analysis of polar phenols in environmental water samples by a combination of ATDB-SCSE and HPLC with diode-array detection was selected as a model for the practical application of the new sorbent. Several extraction conditions, including extraction and desorption time, pH, and ionic strength of the sample matrix were optimized. The results showed that the new monolith had high affinity for polar phenols and could be used to extract them effectively. Under the optimum conditions, low detection (S/N = 3) and quantification (S/N = 10) limits were achieved for the phenols, within the ranges 0.18-0.90 and 0.59-2.97 μg L(-1), respectively. The linearity of the method was good, and the method enabled simple, practical, and low-cost extraction of these analytes. The distribution coefficients between ATDB and water (K(ATDB/W)) were calculated for the phenolic compounds and compared with K(O/W). Finally, the proposed method was successfully applied to the determination of the compounds in three environmental water samples, with acceptable recovery and satisfactory repeatability.

  19. Anisotropic shrinkage characteristics of tape cast alumina

    NASA Astrophysics Data System (ADS)

    Patwardhan, Jaideep Suresh

    Dimensional control during sintering is a major issue in ceramics processing to avoid high post-sintering costs associated with machining of the fired ceramic part to desired tolerances and dimensions. Ceramic forming processes such as tape casting, injection molding, and extrusion involve shear of anisotropic particles resulting in preferential alignment of the particles in the green body. This preferential alignment causes directionality in mechanical, electrical, optical, and magnetic properties and most importantly warpage or distortion during sintering. A large effort has been devoted to synthesizing ceramic green bodies with minimal density gradients and uniform packing and modeling the sintering behavior evolution but little effort has been devoted to characterizing orientation of particles and the effect of preferential alignment on sintering shrinkage anisotropy. A systematic study was initiated to study the effect of processing variables such as shear rate, solids loading, temperature, and binder content on aqueous tape cast alumina. Three different alumina systems: A16-SG, Baikowski RC-UFX DBM and RC-LS DBM were investigated. Aqueous tapes of high solids loading alumina (56 vol. %) were tape cast at various speeds and thicknesses and assuming plane Couette flow a shear rate regime of 21--270 s-1 was investigated. Higher shear rates and high solids loading resulted in higher in-plane anisotropy whereas the anisotropy in the thickness direction was higher for low solids loading systems. The anisotropy was found to be fairly constant above a certain critical shear rate (˜100 s-1) irrespective of the temperature and the solids loading and this correlated with the viscosity-shear rate relationship of the cast slips. The higher shrinkage anisotropy in the thickness direction for the low solids loading systems (35 and 45 vol. %) was attributed to the higher amount of organics in the slip required to sustain the suitable viscosity for tape casting and

  20. Missing physics in stick-slip dynamics of a model for peeling of an adhesive tape.

    PubMed

    De, Rumi; Ananthakrishna, G

    2005-05-01

    It is now known that the equations of motion for the contact point during peeling of an adhesive tape mounted on a roll introduced earlier are singular and do not support dynamical jumps across the two stable branches of the peel force function. By including the kinetic energy of the tape in the Lagrangian, we derive equations of motion that support stick-slip jumps as a natural consequence of the inherent dynamics. In the low mass limit, these equations reproduce solutions obtained using a differential-algebraic algorithm introduced for the earlier equations. Our analysis also shows that the mass of the ribbon has a strong influence on the nature of the dynamics.

  1. Specification for IBM/IBM compatible 3480 tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    This document establishes the same kinds of standards and controls that are currently in use for the procurement on new analog and digital magnetic tapes. The Magnetic Tape Certification Facility (MTCF) currently maintains a Quality Products List (QPL) for all new analog and digital magnetic tapes purchased by NASA-GSFC. Extensive tests are conducted in the MTCF on an annual basis to determine the manufacturer's tape types to be added to or deleted from the current QPL. The MTCF currently maintains two specifications for magnetic tapes: NASA TM-79724 is used for the QPL and acceptance testing of new analog tapes; and NASA TM-80599 is used for the QPL and acceptance testing of new digital tapes. This specification will be used for the QPL and acceptance testing of new 3480 cartridges. The magnetic tapes used by GSFC, LaRC, ARC/Dryden, WFF, and the Network Tracking Stations are covered by the NASA-GSFC specifications. The 3480 cartridge was introduced approximately 3.5 years ago and is becoming an increasingly attractive alternative to digital magnetic tapes. Many users have already converted to the 3480 system and have more tape drives on order.

  2. Deloading tape reduces muscle stress at rest and during contraction.

    PubMed

    Hug, François; Ouellette, Adam; Vicenzino, Bill; Hodges, Paul W; Tucker, Kylie

    2014-12-01

    Taping techniques that aim to protect and reduce stress on an injured tissue during rehabilitation are common in sport. Called deloading tape, the mechanism of action is hypothesized to involve effects ranging from direct mechanical deloading of the underlying soft tissues to psychological effects on confidence. There is no evidence that deloading tape has direct mechanical effects. This study used an elastographic technique (supersonic shear imaging) to test the hypothesis that deloading tape applied to the skin over the rectus femoris would reduce stress within the taped area of this muscle. Thirteen healthy volunteers participated in this experiment. Muscle shear elastic modulus was compared between three treatments (no tape, deloading tape, and sham tape) in four conditions: three conditions without muscle contraction at different rectus femoris muscle-tendon unit lengths (moderately stretched, highly stretched, and shortened) and during submaximal isometric leg extension. Although there was no effect of treatment when the muscle was shortened (P = 0.99), the shear elastic modulus was significantly affected by treatment for the three other conditions (all P < 0.002). Muscle shear elastic modulus was significantly less during application of deloading tape than that during both the no tape and sham tape conditions (all P ≤ 0.001; e.g., vs no tape: moderately stretched, 8.4 ± 2.7 vs 6.7 ± 1.7 kPa; highly stretched, 25.2 ± 8.2 vs 14.4 ± 4.3 kPa; submaximal contraction, 21.3 ± 4.8 vs 14.2 ± 4.3 kPa). Through the use of elastography, this is the first study to support the hypothesis that deloading tape reduces stress in the underlying muscle region, thereby providing a biomechanical explanation for the effect observed during rehabilitation in clinical practice (reduce pain, restore function, and aid recovery). Further investigations are necessary to confirm these results in injured tissues.

  3. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  4. Prophylactic ankle taping: influence on treadmill-running kinematics and running economy.

    PubMed

    Paulson, Sally; Braun, William A

    2014-02-01

    Prophylactic ankle taping (PAT) is commonly used in sport. Prophylactic ankle taping may restrict ankle motion, which would affect the kinetic chain and alter gait. The purpose of this study was to examine the effects of PAT on lower extremity (LE) kinematics and running economy during treadmill running. Twelve recreational runners (9 women, 3 men; M ± SD age = 31.33 ± 8.04 years, height = 1.67 ± 0.81 m, mass = 61.84 ± 9.38 kg) completed two 20-minute running sessions (PAT and no tape: control [CON]) at a self-selected pace. Before each run, reflective markers were placed along the right side of the body. Sagittal plane kinematic data (60 Hz) were captured 4 times, and expired gases were measured for 2-minute after each video capture during both trials. Stride frequency, stride length, LE kinematic variables at initial contact and end contact (EC) were calculated. Cardiorespiratory variables and heart rate were also measured. Running economy was normalized to oxygen uptake per unit body mass per kilometer (milliliter per kilogram per kilometer) as running speeds varied. At EC, the PAT hip angle significantly decreased (p = 0.01) by 3.82°, whereas CON decreased by 0.85°. The range of motion tended to decrease over the 20-minute run (p = 0.08). Heart rate significantly increased over time (6.7%) but was not different between conditions. Prophylactic ankle taping did not significantly affect the physiological measures associated with the metabolic cost of treadmill running or the other kinematic variables. These findings suggest that the hip angle continued to decrease during the PAT condition at push-off in recreational runners without impacting the metabolic cost of transport.

  5. Contact sheet recording with a self-acting negative air bearing

    NASA Technical Reports Server (NTRS)

    Muftu , Sinan (Inventor); Hinteregger, Hans F (Inventor)

    2000-01-01

    A flat head and a tape transport arrangement impart a wrap angle to the tape at the upstream corner of the head. The wrap angle, corner sharpness and tape stiffness are sufficient to cause a moving tape to form a hollow bump at the upstream corner, thereby creating a hollow into which entrained air can expand, causing a subambient pressure within and downstream of the bump. This pressure keeps the tape in contact with the head. It is created without the need for a groove or complex pressure relief slot(s). No contact pressure arises at the signal exchange site due to media wrap. The highest contact pressures are developed at a wrapped upstream corner. For a tape drive, traveling in both forward and reverse, the wrap can be at both the upstream and downstream (which is the reverse upstream) corners. Heads that are not flat can also be used, if the wrap angle relative to a main surface is sufficient and not too large. The wrapped head can also be used with rotating media, such as disks (floppy and hard) and rotating heads, such as helical wound heads for video recording. Multiple flat tape bearing surfaces can be separated by grooves and/or angles. Each flat can carry heads along one or more gap lines. Multiple adjacent narrow tracks can thus be written for extreme high track density recording.

  6. Marine Bioinspired Underwater Contact Adhesion.

    PubMed

    Clancy, Sean K; Sodano, Antonio; Cunningham, Dylan J; Huang, Sharon S; Zalicki, Piotr J; Shin, Seunghan; Ahn, B Kollbe

    2016-05-09

    Marine mussels and barnacles are sessile biofouling organisms that adhere to a number of surfaces in wet environments and maintain remarkably strong bonds. Previous synthetic approaches to mimic biological wet adhesive properties have focused mainly on the catechol moiety, present in mussel foot proteins (mfps), and especially rich in the interfacial mfps, for example, mfp-3 and -5, found at the interface between the mussel plaque and substrate. Barnacles, however, do not use Dopa for their wet adhesion, but are instead rich in noncatecholic aromatic residues. Due to this anomaly, we were intrigued to study the initial contact adhesion properties of copolymerized acrylate films containing the key functionalities of barnacle cement proteins and interfacial mfps, for example, aromatic (catecholic or noncatecholic), cationic, anionic, and nonpolar residues. The initial wet contact adhesion of the copolymers was measured using a probe tack testing apparatus with a flat-punch contact geometry. The wet contact adhesion of an optimized, bioinspired copolymer film was ∼15.0 N/cm(2) in deionized water and ∼9.0 N/cm(2) in artificial seawater, up to 150 times greater than commercial pressure-sensitive adhesive (PSA) tapes (∼0.1 N/cm(2)). Furthermore, maximum wet contact adhesion was obtained at ∼pH 7, suggesting viability for biomedical applications.

  7. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    PubMed Central

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  8. Applicability of DNA analysis on adhesive tape in forensic casework.

    PubMed

    Zech, Wolf-Dieter; Malik, Naseem; Thali, Michael

    2012-07-01

    Adhesive tape is commonly used in crimes and is often the subject of forensic evaluation. DNA analysis of adhesive tape can provide DNA profiles of suspects. The object of this study was to evaluate the applicability of DNA analysis on adhesive tape samples in forensic casework. We retrospectively reviewed all cases involving adhesive tape or similar items received by our institute for DNA analysis during the past 11 years. From 100 forensic cases reviewed, 150 adhesive tape samples were examined. A total of 98 DNA profiles were obtained from these samples. Sixty-two of the profiles provided feasible case-relevant information. In conclusion, DNA profiling of adhesive tape samples can be useful in a variety of forensic cases.

  9. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  10. Assessment of commercially available polymeric materials for sorptive microextraction of priority and emerging nonpolar organic pollutants in environmental water samples.

    PubMed

    Blanco-Zubiaguirre, Laura; Delgado, Alejandra; Ros, Oihana; Posada-Ureta, Oscar; Vallejo, Asier; Prieto, Ailette; Olivares, Maitane; Etxebarria, Nestor

    2014-10-01

    Among the different organic pollutants, persistent organic pollutants and emerging organic contaminants (EOCs) are of particular concern due to their potentially dangerous effects on the ecosystems and on human health. In the framework of the analysis of some of these organic pollutants in water samples, sorptive extraction devices have proven to be adequate for their monitoring. The efficiency of four commercially available and low-cost polymeric materials [polypropylene, poly(ethylene terephthalate), Raffia, and polyethersulfone (PES)] for the simultaneous extraction of 16 organic compounds from five different families from environmental water samples was evaluated in this work. Firstly, the homogeneity of the sorbent materials was confirmed by means of Raman spectroscopy. After the optimization of the parameters affecting the extraction and the liquid desorption steps, it was found that PES showed the largest efficiencies for slightly polar analytes and, to a lesser extent, for nonpolar analytes. Additionally, Raffia rendered good extraction efficiencies for nonpolar compounds. Thus sorptive extraction methods followed by large volume injection-programmable temperature vaporizer-gas chromatography-mass spectrometry were validated using PES and Raffia as sorbent materials. The validation of the method provided good linearity (0.978 < r (2) < 0.999 for PES and 0.977 < r (2) < 0.999 for Raffia), adequate repeatability (below 19 % and 14 % for PES and Raffia, respectively), and low method detection limits (low ng · l(-1) level). Finally, these materials were applied to the analysis of contaminants in environmental water samples.

  11. Hollow fiber-stir bar sorptive extraction and microwave assisted derivatization of amino acids in biological matrices.

    PubMed

    Li, Jia; Qi, Huan-Yang; Wang, Yan-Bin; Su, Qiong; Wu, Shang; Wu, Lan

    2016-11-25

    A kind of solid phase microextraction configuration combining the principles of hollow fiber solid phase microextraction (HF-SPME) and stir bar sorptive extraction (SBSE) is presented. The main feature of HF-SBSE is the use of microporous hollow fiber acting as the carrier and filter, while a thin stainless steel wire and silica microspheres in the lumen of hollow fiber respectively acting as the magnetic stirrer and the dispersed sorbents for the collection and extraction of the target analytes, thus affording extraction process like SBSE. Moreover, the prepared hollow fiber stir bar was applied to direct microextraction and microwave assisted derivatization with N,O-Bis(trimethylsilyl)trifluroacetamide (BSTFA) of four amino acids in rats' urine and cerebrospinal fluid followed by gas chromatography mass spectrometric analysis. The limits of detection for four amino acids were found to be in the range of 0.0003-0.017μgmL(-1), and all the analytes did not exhibit any lack of fit. The extraction recoveries using HF-SBSE techniques ranged from 71.8% to 102.3%. The results indicated that hollow fiber stir bar sorptive extraction was a promising technique for the enrichment and direct derivatization of analytes extracted from biological matrices without sample clean-up.

  12. Dynamic fabric phase sorptive extraction for a group of pharmaceuticals and personal care products from environmental waters.

    PubMed

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Marcé, Rosa Maria; Fontanals, Núria

    2016-07-22

    This paper describes for the first time the use of a new extraction technique, based on fabric phase sorptive extraction (FPSE). This new mode proposes the extraction of the analytes in dynamic mode in order to reduce the extraction time. Dynamic fabric phase sorptive extraction (DFPSE) followed by liquid chromatography-tandem mass spectrometry was evaluated for the extraction of a group of pharmaceuticals and personal care products (PPCPs) from environmental water samples. Different parameters affecting the extraction were optimized and best conditions were achieved when 50mL of sample at pH 3 was passed through 3 disks and analytes retained were eluted with 10mL of ethyl acetate. The recoveries were higher than 60% for most of compounds with the exception of the most polar ones (between 8% and 38%). The analytical method was validated with environmental samples such as river water and effluent and influent wastewater, and good performance was obtained. The analysis of samples revealed the presence of some PPCPs at low ngL(-1) concentrations. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  14. Kinetics of the humid aging of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Bertram, H. N.; Cuddihy, E. F.

    1982-01-01

    The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

  15. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  16. Kinetics of the humid aging of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Bertram, H. N.; Cuddihy, E. F.

    1982-01-01

    The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

  17. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  18. Characterization of BSCCO/Ag tapes and magnets

    SciTech Connect

    Hascicek, Y.S.; Gabor, S.; Shoaff, P.J. Jr.; Weijers, H.W.; Van Sciver, S.W.; Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.

    1994-07-01

    The authors report results on the critical current density J{sub c}(T,H) at various fields and temperatures of Bi-2223/Ag tapes and small coils. In field measurements on small coils were performed under ascending and descending fields to investigate hysteretic behavior. Strain dependence of J{sub c} was obtained by bending heat treated tapes around mandrels of varying diameters. Microstructural results of these tapes by optical microscopy, SEM, EDS, WDS are also presented.

  19. Characterization of Tape Adhesion to Chemical Agent Resistant Coatings

    DTIC Science & Technology

    2015-01-01

    ARL-RP-0517 ● JAN 2015 US Army Research Laboratory Characterization of Tape Adhesion to Chemical Agent Resistant Coatings by...longer needed. Do not return it to the originator. ARL-RP-0517 ● JAN 2015 US Army Research Laboratory Characterization of Tape ...REPORT TYPE Reprint 3. DATES COVERED (From - To) December 2011–May 2014 4. TITLE AND SUBTITLE Characterization of Tape Adhesion to Chemical Agent

  20. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  1. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 1 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 1 through 4. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002139469), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). The primary activity of flight day 1 is the launch of Space Shuttle Endeavour. The crew is seen before the launch at a meal and suit-up, and some pre-flight procedures are shown. Perrin holds a sign with a personalized message. The astronauts communicate with Mission Control extensively after launch, and an inside view of the shuttle cabin is shown. The replays of the launch include close-ups of the nozzles at liftoff, and the fall of the solid rocket boosters and the external fuel tank. Flight day 2 shows footage of mainland Asia at night, and daytime views of the eastern United States and Lake Michigan. Flight day three shows the Endeavour orbiter approaching and docking with the ISS. After the night docking, the crews exchange greetings, and a view of the Nile river and Egypt at night is shown. On flight day 4, the MPLM (Multi-Purpose Logistics Module) Leonardo was temporarily transferred from Endeavour's payload bay to the ISS.

  2. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  3. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  4. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  5. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  6. Structural transitions in model beta-sheet tapes.

    PubMed

    Bellesia, Giovanni; Fedorov, Maxim V; Timoshenko, Edward G

    2008-05-21

    We present a molecular-scale simulation study of the structural transitions between helicoidal, helical, and tubular geometries in supramolecular beta-sheet tapes. Such geometries have been observed in different self-assembled amyloid systems (based on either natural or synthetic peptides) for which the beta-sheet tapes represent the simplest fibrillar aggregates. A coarse-grained model for the beta-sheet tapes is proposed, with chiral degrees of freedom and asymmetrical chemical properties, which provides a quantitative characterization of the structural transitions. A quantitative connection is established between the molecular properties and the elastic parameters of the supramolecular tapes.

  7. Affine transformations from aerial photos to computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Peet, F. G.; Mack, A. R.; Crosson, L. S.

    1974-01-01

    During the development of a project to estimate wheat production, it became necessary to pull data, corresponding to particular fields in a test site, off an ERTS computer compatible tape. Aerial photographs and topographic maps were on hand for the test site. A method was devised, using an affine transformation, to relate the aerial photographs or topographic maps to the tapes. One can thereby access data on the tape corresponding to regions covered by only a few pixels. The theory can be used for the registration of two tapes for the same area and for the geometric correction of images.

  8. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  9. Treatment of stress urinary incontinence with a generic transobturator tape.

    PubMed

    Abougamrah, Amgad; Ibrahim, Moustafa; Elsabaa, Haitham; Ellaithy, Mohamed; Sweed, Mohamed

    2015-09-01

    To evaluate the efficacy and safety of using a generic tape tailored from type 1 monofilamentous, macroporous polypropylene mesh during transobturator tape (TOT) surgery. A prospective study was performed in a tertiary center in Cairo, Egypt, between July 2004 and December 2013. Women with stress urinary incontinence scheduled for TOT surgery using the outside-in technique were recruited. Monarc tape was used in all patients until November 2005, after which it was used for patients who could afford it only; generic tape was used in the other patients. The primary outcome measures were the objective and subjective cure rates. Overall, 431 women were included in analyses. After 5 years of follow-up, objective cure was achieved in 143 (94.1%) of 152 women who received Monarc tape and 249 (89.2%) of 279 who received the generic tape (P=0.135). Subjective cure was achieved in 121 (79.6%) women who received the Monarc tape and 236 (84.6%) women who received the generic tape (P=0.229). There were no significant between-group differences in postoperative urgency, de novo urgency, urge incontinence, voiding dysfunction, urinary retention, vaginal erosion, or the frequency of TOT-related reoperation or repeat anti-incontinence procedures. The TOT outside-in procedure can be easily, safely, and effectively performed in low-resource settings using a generic polypropylene tape. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  10. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary; Brosha, Eric L.; Garzon, Fernando H.

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  11. Effect of α-stable sorptive waiting times on microbial transport in microflow cells

    NASA Astrophysics Data System (ADS)

    Bonilla, F. Alejandro; Cushman, John H.

    2002-09-01

    to the Brownian bacteria motility coefficient (D0 or dispersion coefficient) tb=b2/D0 controls the different adhesion regimes along with the value of α. Universal scalings (with respect to dimensionless time t*=t/tb) for the mean position, =V*efftθ*, and mean-square displacement, <ΔX2>=D*efftγ* exist for long-time dispersion and the coefficients were obtained. The model can account for a great many sorptive processes including reversible and irreversible sorption, and sub- and superdispersive regimes with just a few parameters.

  12. Analysis of biogenic carbonyl compounds in rainwater by stir bar sorptive extraction technique with chemical derivatization and gas chromatography-mass spectrometry.

    PubMed

    Pang, Xiaobing; Lewis, Alastair C; Shaw, Marvin D

    2017-02-01

    Stir bar sorptive extraction is a powerful technique for the extraction and analysis of organic compounds in aqueous matrices. Carbonyl compounds are ubiquitous components in rainwater, however, it is a major challenge to accurately identify and sensitively quantify carbonyls from rainwater due to the complex matrix. A stir bar sorptive extraction technique was developed to efficiently extract carbonyls from aqueous samples following chemical derivatization by O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine hydrochloride. Several commercial stir bars in two sizes were used to simultaneously measure 29 carbonyls in aqueous samples with detection by gas chromatography with mass spectrometry. A 100 mL aqueous sample was extracted by stir bars and the analytes on stir bars were desorbed into a 2 mL solvent solution in an ultrasonic bath. The preconcentration Coefficient for different carbonyls varied between 30 and 45 times. The limits of detection of stir bar sorptive extraction with gas chromatography mass spectrometry for carbonyls (10-30 ng/L) were improved by ten times compared with other methods such as gas chromatography with electron capture detection and stir bar sorptive extraction with high-performance liquid chromatography and mass spectrometry. The technique was used to determine carbonyls in rainwater samples collected in York, UK, and 20 carbonyl species were quantified including glyoxal, methylglyoxal, isobutenal, 2-hydroxy ethanal.

  13. Determination of off-flavor compounds, 2-methylisoborneol and geosmin, in salmon fillets using stir bar sorptive extraction–thermal desorption coupled with gas chromatography–mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A sensitive and solvent-less method for the determination of musty and earthy off-flavor compounds, 2-methylisoborneol (MIB) and geosmin (GSM), in salmon tissue was developed using stir bar sorptive extraction -thermal desorption coupled with gas chromatography -mass spectrometry (SBSE -TD -GCMS). M...

  14. Analysis of biogenic carbonyl compounds in rainwater by stir bar sorptive extraction technique with chemical derivatization and gas chromatography‐mass spectrometry

    PubMed Central

    Lewis, Alastair C.; Shaw, Marvin D.

    2016-01-01

    Stir bar sorptive extraction is a powerful technique for the extraction and analysis of organic compounds in aqueous matrices. Carbonyl compounds are ubiquitous components in rainwater, however, it is a major challenge to accurately identify and sensitively quantify carbonyls from rainwater due to the complex matrix. A stir bar sorptive extraction technique was developed to efficiently extract carbonyls from aqueous samples following chemical derivatization by O‐(2,3,4,5,6‐pentafluorobenzyl) hydroxylamine hydrochloride. Several commercial stir bars in two sizes were used to simultaneously measure 29 carbonyls in aqueous samples with detection by gas chromatography with mass spectrometry. A 100 mL aqueous sample was extracted by stir bars and the analytes on stir bars were desorbed into a 2 mL solvent solution in an ultrasonic bath. The preconcentration Coefficient for different carbonyls varied between 30 and 45 times. The limits of detection of stir bar sorptive extraction with gas chromatography mass spectrometry for carbonyls (10–30 ng/L) were improved by ten times compared with other methods such as gas chromatography with electron capture detection and stir bar sorptive extraction with high‐performance liquid chromatography and mass spectrometry. The technique was used to determine carbonyls in rainwater samples collected in York, UK, and 20 carbonyl species were quantified including glyoxal, methylglyoxal, isobutenal, 2‐hydroxy ethanal. PMID:27928898

  15. Comparison of characteristic flavor and aroma volatiles in melons and standards using solid phase microextraction (SPME) and Stir Bar Sorptive Extraction (SBSE) with GC-MS.

    USDA-ARS?s Scientific Manuscript database

    Stir bar sorptive extraction (SBSE) is a technique for extraction and analysis of organic compounds in aqueous matrices, similar in theory to solid phase microextraction (SPME). SBSE has been successfully used to analyze several organic compounds, including food matrices. When compared with SPME, ...

  16. APPLICATION OF STIR BAR SORPTIVE EXTRACTION TO ANALYSIS OF VOLATILE AND SEMIVOLATILE ORGANIC CHEMICALS OF POTENTIAL CONCERN IN SOLIDS AND AQUEOUS SAMPLES FROM THE HANFORD SITE

    SciTech Connect

    FRYE JM; KUNKEL JM

    2009-03-05

    Stir bar sorptive extraction was applied to aqueous and solid samples for the extraction and analysis of organic compounds from the Hanford chemicals of potential concern list, as identified in the vapor data quality objectives. The 222-S Laboratory analyzed these compounds from vapor samples on thermal desorption tubes as part of the Hanford Site industrial hygiene vapor sampling effort.

  17. Effects of elastic taping, non-elastic taping and static stretching on recovery after intensive eccentric exercise.

    PubMed

    Boobphachart, Disaphon; Manimmanakorn, Nuttaset; Manimmanakorn, Apiwan; Thuwakum, Worrawut; Hamlin, Michael J

    2017-01-25

    The purpose of this study was to compare the effect of elastic tape (Kinesio tape) to placebo tape or static stretching on delayed onset muscle soreness. Fifty-one untrained female healthy volunteers were randomly assigned into three groups (n = 17/group), elastic tape, placebo tape and stretching group. Muscle soreness was induced by 4 sets of 25 maximal isokinetic (60°.s(-1)) eccentric contractions of dominant quadriceps on an isokinetic dynamometer. Compared with placebo tape, the elastic tape participants had less muscle soreness at 72 h post-exercise (p = 0.01). The elastic tape also increased isometric strength at 72 h post-exercise compared with the placebo (p = 0.03) and stretching group (p = 0.02). However, there was little effect between groups for changes in thigh circumference, jumping, pressure pain threshold, rate of perceived exertion, creatine kinase activity and joint motion. Elastic taping increased muscle strength recovery and reduced muscle soreness after intensive exercise.

  18. Does kinesiology tape increase trunk forward flexion?

    PubMed

    Preece, Heidi; White, Peter

    2017-07-01

    Non specific lower back pain is a common musculoskeletal disorder in manual labourers due to the strenuous nature of their job. Fear of pain can cause restrictions in trunk movement leading to reduced flexibility. Kinesiology Tape (KT) may be an option for treating low back stiffness. The present study investigated the immediate effect of KT on trunk flexion active range of motion. 34 male participants (mean age ± SD: 42 ± 11), in physically demanding jobs, asymptomatic of pain, with a history of non specific lower back pain were randomly assigned to: 1) KT Intervention (KTI) or 2) KT Placebo (KTP). Trunk flexion data was collected at baseline and immediately following tape application. ANCOVA was used to examine the differences between groups. The KTI group demonstrated a statistically significant gain in Trunk flexion compared with baseline (2.75 cm, P < 0.05). Changes from pre to post treatment for the KTP were not significant (1.57 cm, P = 0.062). No statistically significant differences existed between groups post-treatment (P = 0.218). KTI demonstrates an immediate positive effect on trunk flexion when compared with baseline measurements. However, results suggest that KTI performs no better than a comparable placebo. Copyright © 2016. Published by Elsevier Ltd.

  19. Rule-based inspection of printed green ceramic tape

    SciTech Connect

    Patek, D.R.; Goddard, J.S.; Karnowski, T.; Lamond, D.; Hawkins, T.A.

    1998-01-01

    A template-based vision system for the 100% inspection of printed flaws on green ceramic tape has been developed. Design goals included a requirement for the detection of flaws as small as two thousandths of an inch on parts up to 8 by 8 inches in size. The inspection engine is a Datacube, Inc., MV200 pipeline processor. As each part is inspected, four 2K by 2K pixel quadrant images are stitched together to construct a single 4K by 4K pixel image with the aid of multiple fiducials located in each quadrant. The part fiducial locations, mask image, and punched-hole position data are generated, beforehand, from CAD designs using a defect map editor (DME), a preprocessing software package developed for the PC. The DME also generates a part ``defect map``. Each unique structure in the printed pattern is defined as an object. Objects are grouped into user-defined categories such as die pads, contact fingers, traces, and electrolysis buses. The map is used during the runtime inspection to associate each detected defect with an object group and a particular defect specification for that group. Repeat defects are optionally tracked for up to three consecutive parts.

  20. Fabrication and characterization of Ag-clad Bi-2223 tapes.

    SciTech Connect

    Balachandran, U.

    1999-04-20

    The powder-in-tube (PIT) technique was used to fabricate multifilament (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes. Transport current properties of these tapes were enhanced by increasing the packing density of the precursor powder and improving the mechanical deformation condition. A critical current (I{sub c}) of > 35 A in long lengths (> 200 m) tapes has been achieved. In measuring the dependence of critical current density on magnetic field and temperature for the optimally processed tapes, we found a J{sub c} of > 10{sup 4} A/cm{sup 2} at 20 K in magnetic fields up to 3 T and parallel to the c-axis, which is of interest for use in refrigerator-cooled magnets. I{sub c} declined exponentially when an external field was applied perpendicular to the tape surface at 77 K. Mechanical stability was tested for tapes sheathed with pure Ag and Ag-Mg alloy. Tapes made with pure Ag sheathing can withstand a tensile stress of {approx}20 MPa with no detrimental effect on I{sub c} values. Mechanical performance was improved by using Ag-Mg alloy sheathing: values of transport critical current began to decrease at the tensile stress of {approx} 100 MPa. Transport current measurements on tapes wound on a mandrel of 3.81 cm (1.5 in.) diameter at 30{degree} to the longitudinal axis, showed a reduction of {approx} 10% in I{sub c} values for pure Ag-sheathed tapes and 5% reduction in I{sub c} values for Ag-Mg sheathed tapes, compared with the I{sub c} values of as-coiled tapes.

  1. Thermal performance enhancement in tubes using helically twisted tape with alternate axis inserts

    NASA Astrophysics Data System (ADS)

    Yongsiri, K.; Thianpong, C.; Nanan, K.; Eiamsa-ard, S.

    2016-01-01

    This article presents an investigation on heat transfer enhancement in a round tube inserted with a helically twisted tape. The effects of a helically twisted tape with alternate axis (HTT-A) on heat transfer, friction factor, and thermal performance factor behaviours are reported for the turbulent regime. HTT-A geometries are tape pitch to tube diameter, P/D = 1.0, 1.5, and 2.0; alternate length to pitch length, l/P = 1.0, 1.5, and 2.0; twisted length to tape width, y/W = 3.0; and tape width to tube diameter, w/D = 0.2. The experiment has been performed by varying the volumetric air flow rate in order to adjust Reynolds number ranging from 6 000 to 20 000. The wall of the testing tube is uniformly heated as a constant heat flux while the tests are covered with thermal insulations to reduce heat loss to surroundings. Thermal performance is evaluated by comparing the present experimental results with the results of the modified HTT-A and also those obtained from previous study (conventional helically twisted tape, HTT). The thermal performance of tested tube with HTT-A is evaluated to obtain the degree of heat transfer enhancement and friction factor induced by HTT-A with respect to the plain tube under the same test conditions. Evenly, it is interesting to observe that the tube with HTT-A consistently possesses higher heat transfer and thermal performance factor than those with the HTT around 14.1% and 1.9%, respectively. The HTT-A with the smaller pitch ratio and adjacent twist length provides higher heat transfer rate and friction factor than the one with larger pitch ratio and alternate length as a result of a larger contact surface area, stronger swirl intensity and, thus, better fluid mixing near the tube wall. In the range determined, the tubes with the largest pitch ratio ( P/D = 2.0) and smallest alternate length ( l/P = 1.0) give the highest thermal performance factor at around 1.35. In addition, the empirical correlations of the Nusselt number, friction

  2. A CLASSIFICATION AND RETRIEVAL SYSTEM FOR RECORDED FOREIGN LANGUAGE TAPES.

    ERIC Educational Resources Information Center

    KAY, J.B.; JAMESON, A.

    A CLASSIFICATION SYSTEM FOR FOREIGN LANGUAGE RECORDINGS, DEVISED FOR USE AT THE UNIVERSITY OF ESSEX, IS DESCRIBED IN THIS ARTICLE. CODING AND CROSS-REFERENCE SYSTEMS FOR THE VARIOUS CATEGORIES OF TAPES ARE OUTLINED, AND SPECIFIC EXAMPLES ARE INCLUDED. APPENDED IS A LIST OF TAPE REFERENCE CODES. THE SYSTEM OUTLINED IS NOT CONSIDERED IDEAL, BUT IT…

  3. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  4. Library and Reference Applications: Census Tapes and Printed Reports.

    ERIC Educational Resources Information Center

    Anders, Mary Edna

    Census tapes are not a ready reference tool and must be supported by appropriate program tapes. However, census materials provide the single, most important sources of information and measures which, properly used, provide a better understanding of our society. In utilizing census products, librarians need to fill the role of a user, as well as…

  5. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  6. The use of paper tape in wound closures.

    PubMed

    Danto, L A; Albertazzi, V J; Elliott, T E; Love, F G

    1986-12-01

    The techniques described using paper tape in wound closure have been found to be cosmetically equal to or better than other forms of wound closure. Paper tape provides better support, is more versatile and care free, while being easier to use and less expensive than Steri Strips.

  7. Design Your Organization's Own Slide-Tape Show

    ERIC Educational Resources Information Center

    Tilden, Scott W.

    1975-01-01

    Slide-tape shows offer a relatively inexpensive, easy-to-assemble means of informing a wide variety of groups interested in education. This article outlines a seven-step procedure to produce a coherent, professional-looking slide-tape presentation. (DS)

  8. Tape Recorders and the Commuter Student: Bypassing the Red Pen.

    ERIC Educational Resources Information Center

    Kates, Ronald

    1998-01-01

    Discusses several ways in which tape-recorded responses by the instructor to student writing can benefit commuter students. Discusses how the audio cassette responses are paired with a series of questions on the writing process and how the author shapes his tape-recorded comments. Notes student responses about the advantages of this approach. (SR)

  9. [Adhesive tape on the face--criminalistic aspects].

    PubMed

    Tomforde, Anja; Tsokos, Michael; Anders, Sven; Püschel, Klaus

    2003-01-01

    Under forensic differential diagnostic aspects postmortem findings of adhesive tape in the face suggest either suicide, an autoerotic accident or homicide, in which case the adhesive tape could have been used for sealing the mouth or as a means to commit the homicide itself. 9 autopsy cases are described as examples with this constellation and discussed under criminological aspects.

  10. Silver-clad ? superconducting tapes fabricated by different mechanical processing

    NASA Astrophysics Data System (ADS)

    Guo, Y. C.; Liu, H. K.; Dou, S. X.; Kuroda, T.; Tanaka, Y.

    1998-10-01

    0953-2048/11/10/032/img10/silver composites were fabricated by drawing a silver tube packed with precursor powders into round wire and deforming the round wire into flat tapes by longitudinal rolling, transverse rolling and uniaxial pressing respectively. The resultant tapes were observed by optical microscopy to examine the superconductor core/silver interface. Short pieces were cut from the tapes and heat-treated by a thermomechanical process consisting of alternate sintering and intermediate mechanical deformation. Intermediate deformation was carried out for each tape using the method by which the tape was formed. The effect of different deformations on the microstructure and transport property of the final tapes was investigated. It was found that deformation method affected the core/silver interface of tapes significantly. Pressing produced a wavier core/silver interface (sausaging) and more cracks than longitudinal and transverse rolling. As for critical current density, pressing yielded the highest value, due to the higher density and better grain alignment in the pressed tapes than in the longitudinal and transverse rolled ones.

  11. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... COMMISSION Pressure Sensitive Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed... antidumping duty finding on pressure sensitive plastic tape from Italy would be likely to lead to continuation... Commission are contained in USITC Publication 4128 (March 2010), entitled Pressure Sensitive Plastic...

  12. Using a Taped Intervention to Improve Kindergarten Students' Number Identification

    ERIC Educational Resources Information Center

    Krohn, Katherine R.; Skinner, Christopher H.; Fuller, Emily J.; Greear, Corrine

    2012-01-01

    A multiple baseline design across students was used to evaluate the effects of a taped numbers (TN) intervention on the number-identification accuracy of 4 kindergarten students. During TN, students attempted to name the numbers 0 through 9 on randomized lists before each number was provided via a tape player 2 s later. All 4 students showed…

  13. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  14. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  15. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  16. The use of McConnell taping to correct abnormal biomechanics and muscle activation patterns in subjects with anterior knee pain: a systematic review

    PubMed Central

    Leibbrandt, Dominique C; Louw, Quinette A

    2015-01-01

    [Purpose] The aim of this review was to present the available evidence for the effect of McConnell taping on knee biomechanics in individuals with anterior knee pain. [Methods] The PubMed, Medline, Cinahl, SPORTDiscus, PEDro and ScienceDirect electronic databases were searched from inception until September 2014. Experimental research on knee biomechanical or EMG outcomes of McConnell taping compared with no tape or placebo tape were included. Two reviewers completed the searches, selected the full text articles, and assessed the risk of bias of eligible studies. Authors were contacted for missing data. [Results] Eight heterogeneous studies with a total sample of 220 were included in this review. All of the studies had a moderate to low risk of bias. Pooling of data was possible for three outcomes: average knee extensor moment, average VMO/VL ratio and average VMO-VL onset timing. None of these outcomes revealed significant differences. [Conclusion] The evidence is currently insufficient to justify routine use of the McConnell taping technique in the treatment of anterior knee pain. There is a need for more evidence on the aetiological pathways of anterior knee pain, level one evidence, and studies investigating other potential mechanisms of McConnell taping. PMID:26311990

  17. Tape-Drive Based Plasma Mirror

    SciTech Connect

    Sokollik, Thomas; Shiraishi, Satomi; Osterhoff, Jens; Evans, Eugene; Gonsalves, Anthony; Nakamura, Kei; vanTilborg, Jeroen; Lin, Chen; Toth, Csaba; Leemans, Wim

    2011-07-22

    We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots. In order to design a compact, staged laser plasma based accelerator or collider [1], the coupling of the laser beam into the different stages represents one of the key issues. To limit the spatial foot print and thus to realize a high overall acceleration gradient, a concept has to be found which realizes this in-coupling within a few centimeters (cf. Fig 1). The fluence of the laser pulse several centimeters away from the acceleration stage (focus) exceeds the damage threshold of any available mirror coating. Therefore, in reference [2] a plasma mirror was suggested for this purpose. We present experiments on a tape-drive based plasma mirror which could be used to reflect the focused laser beam into the acceleration stage. Plasma mirrors composed of antireflection coated glass substrates are usually used to improve the temporal laser contrast of laser pulses by several orders of magnitudes [3,4]. This is particularly important for laser interaction with solid matter, such as ion acceleration [5,6] and high harmonic generation on surfaces [7]. Therefore, the laser pulse is weekly focused onto a substrate. The main pulse generates a plasma and is reflected at the critical surface, whereas the low intensity pre-pulse (mainly the Amplified Spontaneous Emission pedestal) will be transmitted through the substrate before the mirror has been triggered. Several publications [3,4] demonstrate a conservation of the spatial beam quality and a reflectivity of about 70 %. The drawback of this technique is the limited repetition rate since for every shot a fresh surface has to be provided. In the past years several novel approaches for high repetition rate plasma mirrors have been developed [2, 8

  18. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  19. BACKUP -- Recovering from incremental tape backups

    NASA Astrophysics Data System (ADS)

    Allan, P. M.

    The importance of making regular backups of your disks in well known, but it can be very frustrating to have a head crash and then discover that you cannot recover from your backups because the manuals do not tell you what to do. The DEC documentation covers most possibilities, but not the case where a removable pack is copied to a new pack, the new pack is then used as the current pack, and incremental backups to tape are then made. This situation is a fairly common one when you have two or more removable disk drives. This note covers backup and recovery in general terms, and details exactly what to do in the above mentioned case.

  20. Progress in BSCCO-2223 tape technology

    NASA Astrophysics Data System (ADS)

    Malozemoff, A. P.; Li, Q.; Fleshler, S.

    1997-08-01

    ASC multifilamentary composite tape based on BSCCO-2223 high temperature superconductor (HTS) and a scalable rolling process has reached a record superconductor critical current density J c (77 K, 0 T) of up to 58,000 A/cm 2, and engineering (full cross-section including metal sheath) J e (77 K, 0 T) up to 15,000 A/cm 2. Pilot manufacturing of long lengths (100-400 m) has permitted a variety of increasingly significant prototypes, including a 200 hp ac synchronous motor, a 3300 A (77 K) 50 m machine-stranded cable conductor, a 5 kJ SMES system, and an operational ion-beam switching magnet installed in a tandem accelerator for carbon mass spectrometry dating. Recent ASC progress in manufacturing with Je over 8000 A/cm 2 creates new opportunities for yet more advanced prototypes and commercial development.

  1. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  2. Monitoring volatile compounds production throughout fermentation by Saccharomyces and non-Saccharomyces strains using headspace sorptive extraction.

    PubMed

    Morales, M L; Fierro-Risco, J; Callejón, R M; Paneque, P

    2017-02-01

    Currently, there is a growing interest in the use of non-Saccharomyces yeast to enhance the aromatic quality of wine, with pure or mixed cultures, as well as sequential inoculation. Volatile components of wines were closely related to their sensory quality. Hence, to study the evolution of volatile compounds during fermentation was of great interest. For this, sampling methods that did not alter the volume of fermentation media were the most suitable. This work reports the usefulness of headspace sorptive extraction as non-invasive method to monitor the changes in volatile compounds during fermentation. This method allowed monitoring of 141 compounds throughout the process of fermentation by Saccharomyces cerevisiae and Lachancea thermotolerans strains. Both strains showed a similar ability to ferment a must with high sugar content. The S. cerevisiae strain produced higher amount of volatile compounds especially esters that constitutes fruity aroma than L. thermotorelans.

  3. Stir bar sorptive extraction of volatile compounds in vinegar: validation study and comparison with solid phase microextraction.

    PubMed

    Guerrero, Enrique Durán; Marín, Ramón Natera; Mejías, Remedios Castro; Barroso, Carmelo García

    2007-10-05

    Stir bar sorptive extraction was evaluated for analysing volatiles in vinegar. The procedure developed shows detection and quantitation limits, and linear ranges adequate for analysing this type of compounds. The accuracy obtained was close to 100%, with repeatability values lower than 13%. The extraction efficiency is inversely affected by the acetic acid content. Although the absolute areas decrease, the compound area/internal standard area ratio remains constant, so for quantitative analysis, the acetic acid concentration does not affect the analytical data. The method was compared with a previous SPME method. Similar performance characteristics were obtained for both methodologies, with lower detection and quantitation limits and better repeatability reproducibility values for SBSE. Both analytical methods were used to analyse a variety of vinegars. The results obtained from both methods were in agreement.

  4. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    PubMed

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  5. A composite athletic tape with hyperelastic material properties improves and maintains ankle support during exercise.

    PubMed

    Siegler, Sorin; Marchetto, Paul; Murphy, Daniel J; Gadikota, Hemanth R

    2011-12-01

    Controlled laboratory testing using a single-group, prospective, repeated-measures design. To compare the material properties of a hyperelastic athletic tape to a conventional tape and to compare the passive ankle support of these tapes before and after exercise. The near-linear material properties of conventional athletic tape may interfere with ankle motion, resulting in reduced athletic performance. Conventional athletic tape is also known to lose much of its initial support during exercise. It was assumed that a tape constructed of Kevlar fibers embedded in a silicon matrix would possess hyperelastic material properties that would improve ankle support. A tensile testing machine was used to determine the tensile material properties of 11 samples of conventional and hyperelastic tape. The ankles of 11 young, healthy athletes were taped, one ankle with conventional tape and the other ankle with hyperelastic tape. The passive ankle support of each tape was measured with an instrumented linkage (the ankle flexibility tester) before and after 30 minutes of exercise. The composite tape had a significantly higher load to failure than the conventional tape. It had significantly lower initial stiffness and higher late stiffness than conventional tape, thus demonstrating highly hyperelastic behavior. The hyperelastic tape maintained a significantly higher portion of its support during the 30 minutes of exercise than the conventional tape. Composite athletic tape with highly hyperelastic properties can be constructed and maintains a larger portion of its support during short-duration exercises (less than 30 minutes) than conventional athletic tape.

  6. New medium-to-high polarity twister coatings for liquid and vapour phase sorptive extraction of matrices of vegetable origin.

    PubMed

    Sgorbini, Barbara; Cagliero, Cecilia; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Ruosi, Manuela Rosanna; Bicchi, Carlo

    2012-11-23

    Stir Bar Sorptive Extraction (SBSE) is a solventless sampling technique first introduced to extract organic analytes from aqueous samples, in the following applied to headspace sampling (HeadSpace Sorptive Extraction - HSSE). In SBSE and HSSE, analytes are sorbed onto a thick film of polydimethylsiloxane (PDMS) coating a glass-coated magnet. However, PDMS is apolar and not highly effective in recovering polar analytes (i.e. with logK(o/w) below 2), making difficult their sampling in complex matrices. A new generation of medium-to-high polarity polymeric coatings for twisters i.e. polyethyleneglycol-modified silicone (EG) and polyacrylate/polyethyleneglycol (PA) has recently been introduced to overcome this limit. In this study, EG and PA twisters have been applied to SBSE and HSSE of a number of dedicated standard mixtures and real-world samples of vegetable origin to evaluate their capability to increase recovery of medium to highly polar analytes. The results obtained, expressed as percent concentration factor (CF%) versus PDMS twisters taken as reference, showed that analyte logK(o/w) is a key-factor driving the choice of the most effective coating. The new twisters showed to be successful for both SBSE and HSSE, although to a different extent. EG twisters gave high recoveries with analytes over a wide range of polarities and in particular with logK(o/w) below 2 and/or containing hydroxyl or carboxylic functional groups independently on their logK(o/w). On the other hand, PA twisters were selectively effective for highly polar compounds with logK(o/w) below 1.

  7. Contact hysteroscopy.

    PubMed

    Baggish, M S; Barbot, J

    1983-06-01

    In 1907 innovations in optics and illumination made by Maximilian Nitze were applied to hysteroscopy by Charles David, who wrote a treatise of hysteroscopy. David improved illumination by placing an electric incandescent bulb at the intrauterine end of his endoscope and also sealed the distal end of the tube with a piece of glass. The history of the contact endoscope that the authors personally used is connected to the invention by Vulmiere (1952) of a revolutionary illumination process in endoscopy--the "cold light" process. The components of cold light consist of a powerful external light source that is transmitted via a special optical guide into the endometrial cavity. The 1st application of his principle (1963) was an optical trochar contained in a metallic sheath. This simple endoscope was perfected, and in 1973 Barbot and Parent, in France, began to use it to examine the uterine cavity. Discussion focuses on methods, instrumentation, method for examination (grasping the instrument, setup, light source, anesthesia, dilatation, technique, and normal endometrium); cervical neoplasia; nonneoplastic lesions of the endometrium (endometrial polyp, submucous myoma, endometrial hyperplasia); intrauterine device localization; neoplastic lesions of the endometrium; precursors (adenocarcinoma); hysteroscopy in pregnancy (embryoscopy, hydatidiform mole, postpartum hemorrhage, incomplete abortion, spontaneous abortion, induced abortions, and amnioscopy); and examinations of children and infants. The contact endoscope must make light contact with the structure to be viewed. The principles of contact endoscopy depend on an interpretation of color, contour, vascular pattern, and a sense of touch. These are computed together and a diagnosis is made on the basis of previously learned clinical pathologic correlations. The contact endoscope is composed of 3 parts: an optical guide; a cylindric chamber that collects and traps ambient light; and a magnifying eyepiece. The phase of

  8. Impression Smear Agreement with Acetate Tape Preparation for Cytologic Sampling.

    PubMed

    Layne, Elizabeth A; Zabel, Sonja

    Cutaneous cytologic sampling techniques are used to detect bacteria, yeast, and inflammatory cells for diagnosis and therapeutic monitoring. Studies have examined slide evaluation techniques, ear swab cytology staining methods, and observer variations; few studies compare common clinical sampling techniques. The primary aim of this study was to measure detection of microorganisms and neutrophils by impression smear compared to acetate tape preparation; comparison of agreement between two acetate tape staining methods was a secondary aim. Thirty lesions consistent with superficial pyoderma were sampled via impression smear and acetate tape preparation. Acetate tape preparations were either stained with modified Romanowksy stain solutions two and three or solution three alone. Impression smears were stained in the standard manner. Bacteria, yeast, and neutrophils were evaluated using a semi-quantitative scale [0-4]. Quantities were aggregated and compared using Cohen's kappa to measure agreement between methods. When impression smears were compared to acetate tape, the lowest agreement occurred for neutrophils, with impression smears detecting more neutrophils. Comparison of acetate tape staining methods had the highest agreement for yeast detection. Sampling technique and staining method did not differ for detection of bacteria. Impression smears detected more neutrophils, and yeast detection appeared equivalent for acetate tape staining methods.

  9. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  10. Ankle taping can improve proprioception in healthy volunteers.

    PubMed

    Miralles, Iris; Monterde, Sónia; Montull, Salvador; Salvat, Isabel; Fernández-Ballart, J; Beceiro, Judith

    2010-12-01

    Taping is a common technique to treat inversion ankle sprains, but the effects of tape on proprioception are still not clear. The purpose of this study was to establish whether proprioception would be modified by the use of ankle tape. To do so we studied joint position sense (JPS) in healthy volunteers using three-dimensional (3D) movement analysis systems. Forty healthy volunteers (mean age and SD = 23.2 ± 4.2) were asked to actively reproduce four different ankle positions: 10 degrees of dorsiflexion, neutral, 10 degrees and 20 degrees of plantarflexion. The absolute difference between the estimated angle and the target angle was used to assess JPS. This difference was named Error. Subjects were randomly assigned to the control (n = 21) or the intervention (n = 19) groups. Members of the intervention group received ankle tape for a lateral ligament sprain in the non-dominant leg. A t-test was used to evaluate the results. Tape significantly improved JPS for the dorsiflexion position (p = 0.038). Neutral was the most accurately reproduced position, and the remaining positions were overestimated for both groups. Taping improved proprioception in healthy volunteers, and 3D movement analysis was a useful method to accurately quantify joint position sense. Because ankle proprioception is critical to the functional success of surgical and rehabilitation treatments, these results regarding proprioception are of particular importance because ankle taping is often used in preventing ankle sprains and it is a common treatment after ankle injuries.

  11. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  12. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  13. Tape extensometer sensitivity and reliability. [Climax fuel storage at NTS

    SciTech Connect

    Yow, J.L. Jr.; Wilder, D.G.

    1981-09-21

    The Spent Fuel Test-Climax is a test of retrievable storage in granite of spent nuclear reactor fuel. The rock has been instrumented to measure temperatures, stress changes, and displacements. Periodic tape extensometer readings provide test drift convergence data. Vertical and horizontal tape readings are made at five locations in each of two 3.4m x 3.4m (11 ft x 11 ft) drifts and six locations in a 4.6m x 6.2m (15 ft x 20.5 ft) drift. The sensitivity of the readings to temperature effects, errors in temperature corrections, change of steel tape, and change of operator has been examined. Calculated corrections for temperature-induced changes in distance range from 0.001 in. to 0.003 in.//sup 0/C. A tape changeout evidenced both a systematic error apparently due to slight changes in tape registration during punching and to nonidentical location of punched holes in the two tapes and a random error due to variability of reading and punching operations. These errors were corrected by making duplicate measurements for the tapes. Tape readings by the same operator have been repeatable within +-0.001 in. in the smaller drifts and +-0.002 in. in the larger. Different operators have been able to repeat readings to within +-0.004 in. (usually within +-0.002 in.) with generally consistent direction of offset between operators. Corrections of readings and review of plotted data show the tape extensometer to be a reliable instrument for tunnel convergence measurements.

  14. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  15. Highly selective and sensitive analysis of dopamine by molecularly imprinted stir bar sorptive extraction technique coupled with complementary molecularly imprinted polymer sensor.

    PubMed

    Prasad, Bhim Bali; Srivastava, Amrita; Tiwari, Mahavir Prasad

    2013-04-15

    This paper reports a combination of molecularly imprinted stir bar sorptive extraction and complementary molecularly imprinted polymer-sensor for the analysis of dopamine as a biomarker of several neurodegenerative diseases occurred at ultra trace level. This exploited iniferter initiated polymerization via "surface grafting-from" approach onto magnetic stir bar (for sorptive extraction) and multiwalled carbon nanotubes-ceramic electrode (for detection). Such hyphenation helped dual pre-concentration of dopamine in aqueous, biological and pharmaceutical samples. This enabled high sensitivity to achieve the stringent limit [limit of detection: 4.9ngL(-1), RSD=2.4%, S/N=3, cerebrospinal fluid] of clinical detection, without any problems of non-specific contributions and cross-reactivity.

  16. Prioritized Contact Transport Stream

    NASA Technical Reports Server (NTRS)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  17. Types of Contact Lenses

    MedlinePlus

    ... Consumer Devices Consumer Products Contact Lenses Types of Contact Lenses Share Tweet Linkedin Pin it More sharing ... Orthokeratology (Ortho-K) Decorative (Plano) Contact Lenses Soft Contact Lenses Soft contact lenses are made of soft, ...

  18. Development of a fabric phase sorptive extraction with high-performance liquid chromatography and ultraviolet detection method for the analysis of alkyl phenols in environmental samples.

    PubMed

    Kumar, Rajesh; Gaurav; Kabir, Abuzar; Furton, Kenneth G; Malik, Ashok Kumar

    2015-07-06

    A novel analytical method has been developed and validated for the quantification of alkyl phenols in aqueous and soil samples. Fabric phase sorptive extraction, a new sorptive microextraction technique, has been employed for the preconcentration of some endocrine-disruptor alkylphenol molecules, namely, 4-tert-butylphenol, 4-sec-butylphenol, 4-tert-amylphenol, and 4-cumylphenol, followed by high-performance liquid chromatography with ultraviolet detection. Various parameters influencing the fabric phase sorptive extraction performance, namely, extraction time, eluting solvent, elution time and pH of the sample matrix, were optimized. The chromatographic separation was carried out with a mobile phase of acetonitrile/water (60:40 v/v) at an isocratic flow rate of 1.0 mL/min using a reversed-phase C18 column at λmax 225 nm. The calibration curves of target analytes were prepared in the concentration range 5-500 ng/mL with good coefficient of determination values (R(2) > 0.992). Extraction efficiency values were 74.0, 75.6, 78.0, and 78.3 for 4-tert-butylphenol, 4-sec-butylphenol, 4-tert-amylphenol, and 4-cumylphenol, respectively. The limits of detection range from 0.161 to 0.192 ng/mL. Subsequently, the new fabric phase sorptive extraction with high-performance liquid chromatography and ultraviolet detection was successfully applied for the recovery of alkyl phenols from spiked ground water, river water, and treated water from a sewage treatment plant, and soil and sludge samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  20. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  1. REBCO tape performance under high magnetic field

    NASA Astrophysics Data System (ADS)

    Benkel, Tara; Miyoshi, Yasuyuki; Chaud, Xavier; Badel, Arnaud; Tixador, Pascal

    2017-08-01

    New improvements in high temperature superconductors (HTS) make them a promising candidate for building the next generation of high field magnets. As the conductors became recently available in long length, new projects such as NOUGAT (new magnet generation to generate Tesla at low cost) were started. This project aims at designing and building an HTS magnet prototype generating 10 T inside a 20 T resistive magnet. In this configuration, severe mechanical stress is applied on the insert and its extremities are subject to a high transverse component of the field. Because the conductor has anisotropic properties, it has to be studied carefully under similar conditions as the final prototype. First, this paper presents both the NOUGAT project and its context. Then, it shows the experimental results on short HTS tapes studied under high magnetic field up to 23 T with varying orientation. These results allow validating the current margin of the prototype. Finally, a first wound prototype is presented with experimental results up to 200 A under 16 T. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2016)", edited by Adel Razek

  2. "Sound" Learning: Using Taped Interviews in Foreign Language Courses.

    ERIC Educational Resources Information Center

    Frommer, Judith G.; Weitz, Margaret Collins

    1981-01-01

    Describes development and implementation of authentic sound documents in foreign language classes including use of transcripts, recording tapes, background materials, listening aids, and follow-up and expansion activities such as student booklets. (BK)

  3. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  4. 4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE FACILITY; VIEW TO NORTHEAST. - Cape Canaveral Air Station, Launch Complex 17, Facility 36002, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  5. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  6. 34. Perimeter acquisition radar building room #325, tape handler room ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Perimeter acquisition radar building room #325, tape handler room - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND

  7. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTH - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  8. 11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM FLOOR OF DRYDOCK NO. 5. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA

  9. Magnetic Imaging of Superconducting Tapes to Determine Current Flow

    NASA Astrophysics Data System (ADS)

    Mueller, Fred M.; Brown, David J.; Hawley, Marilyn E.; Brown, Geoffrey W.; Yates Coulter, J.

    2000-03-01

    We have developed a magnetic imaging system which yields quantitative information about the magnetic field near the surface of a superconducting tape while it is carrying current at liquid nitrogen temperatures. The imaging system is based on a mechanical scanner with motion coupled into a dewar and uses standard magnetoresistive read heads from computer hard disk drives as the sensor elements. We have numerically inverted the external magnetic field data from silver-coated YBCO tapes to derive the internal tape current densities. Preliminary results are consistent with the expected patterns in the tapes, obey sum rules, and exhibit time reversal symmetry. Preliminary current flow paths suggest that the current density can be non-uniform.

  10. Creating and Using Video Tapes for Cartographic Demonstrations.

    ERIC Educational Resources Information Center

    Andrews, Sona K.; Gersmehl, Philip J.

    1986-01-01

    Offers nine suggestions for video tape production and instructional use in a student laboratory for a cartography course. Briefly discusses costs and benefits, including more time for instructors to focus on specific techniques and individual questions. (TRS)

  11. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR...

  12. 13. DETAIL SHOWING EXPOSED VERTICAL LOG CONSTRUCTION WITH MEASURING TAPE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. DETAIL SHOWING EXPOSED VERTICAL LOG CONSTRUCTION WITH MEASURING TAPE, WEST ROOM AT REAR OF HOUSE, FIRST FLOOR - Pierre Delassus DeLuziereHouse, U.S. Route 61, Sainte Genevieve, Ste. Genevieve County, MO

  13. 12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  14. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  15. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  16. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  17. Measurement of Elastic Modulus of Alumina and Barium Strontium Titanate Wafers Produced by Tape Casting Method

    DTIC Science & Technology

    2014-02-01

    TITANATE WAFERS PRODUCED BY TAPE CASTING METHOD Shri N. Singh February 2014 Approved for public release... TAPE CASTING METHOD 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS Shri N. Singh 5d. PROJECT...sawing method (pelletizing method), as well as a tape casting technique. Samples of aluminum oxide (alumina) were made by a tape casting method

  18. 75 FR 17124 - Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of Antidumping Duty Finding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... International Trade Administration Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of... plastic tape (PSP Tape) from Italy would be likely to lead to continuation or recurrence of dumping and of... to be revoked. See Pressure Sensitive Plastic Tape from Italy: Final Results of Expedited...

  19. Comparative study of different fabric phase sorptive extraction sorbents to determine emerging contaminants from environmental water using liquid chromatography-tandem mass spectrometry.

    PubMed

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Fontanals, Núria; Marcé, Rosa Maria

    2015-11-01

    A new sorptive extraction technique, fabric phase sorptive extraction (FPSE), using different coating chemistries: non-polar sol-gel poly(dimethyldiphenylsiloxane) (PDMDPS), medium polar sol-gel poly(tetrahydrofuran) (PTHF), and polar sol-gel poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG triblock) and sol-gel Carbowax 20 M were evaluated to extract a group of pharmaceuticals and personal care products (PPCPs) with wide range of polarity from environmental aqueous samples. Different parameters affecting FPSE such as sample pH, stirring speed, addition of salt, extraction time, sample volume, elution solvent and desorption time were optimized for each sorbent coated FPSE media. Under optimum conditions, FPSE media coated with sol-gel Carbowax 20 M provided the highest absolute recoveries (77-85%) for majority of the analytes with the exception of the most polar ones. Nevertheless, all four sorbents offered better recovery compared to the commercially available coating for stir-bar sorptive extraction based on Ethylene Glycol/Silicone (EG/Silicone). The method based on FPSE with sol-gel Carbowax 20 M media and liquid chromatography-(electrospray ionization) tandem mass spectrometry (LC-(ESI) MS/MS) was developed and validated for environmental water samples. Good apparent recoveries (41-80%), detection limits (1-50 ng L(-1)), repeatability (%RSD<15%, n=5) and reproducibility (%RSD<18%, n=5) were achieved.

  20. Determination of short chain chlorinated paraffins in water by stir bar sorptive extraction-thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Tölgyessy, P; Nagyová, S; Sládkovičová, M

    2017-03-08

    A simple, robust, sensitive and environment friendly method for the determination of short chain chlorinated paraffins (SCCPs) in water using stir bar sorptive extraction (SBSE) coupled to thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry (TD-GC-QqQ-MS/MS) was developed. SBSE was performed using 100mL of water sample, 20mL of methanol as a modifier, and a commercial sorptive stir bar (with 10mm×0.5mm PDMS layer) during extraction period of 16h. After extraction, the sorptive stir bar was thermally desorbed and online analysed by GC-MS/MS. Method performance was evaluated for MilliQ and surface water spiked samples. For both types of matrices, a linear dynamic range of 0.5-3.0μgL(-1) with correlation coefficients >0.999 and relative standard deviations (RSDs) of the relative response factors (RRFs) <12% was established. The limits of quantification (LOQs) of 0.06 and 0.08μgL(-1), and the precision (repeatability) of 6.4 and 7.7% (RSDs) were achieved for MilliQ and surface water, respectively. The method also showed good robustness, recovery and accuracy. The obtained performance characteristics indicate that the method is suitable for screening and monitoring and compliance checking with environmental quality standards (EQS, set by the EU) for SCCPs in surface waters.

  1. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  2. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    additional analysis done in SOLIDWORKS . For the first method of analysis, PolyWorks is used to cut out the unnecessary portions of the raw scan data. Then...each tape spring is exported as a ‘.stl’ file. This file is imported as a surface into a SOLIDWORKS part file. The SOLIDWORKS parts are combined into...analyzed using MATLAB, PolyWorks, and SOLIDWORKS . These data provide a greater insight into the stress relaxation of tape springs when deformed

  3. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  4. Outcome of transvaginal mesh and tape removed for pain only.

    PubMed

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Digital high density (80 Mb/s) tape

    NASA Technical Reports Server (NTRS)

    Donner, M. D.

    1977-01-01

    Work with a state-of-the-art high density PCM tape recorder reproducer system is described. The tape recorder is designed for 80 Mb/s operation at an overall bit error rate of .00001and for 40 Mb/s operation at .000001. The article describes the process of measuring the error rate. Also detailed is a data rate buffer designed for use in recent radar experiments and generalizable to most potential uses of the recorder system.

  6. FGGE/SBUV tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/SBUV Level 2C data set consists of 12 9-track data tapes, each of which contains total ozone and ozone profile data for one calendar month grouped in files containing the data in a 6 hour synoptic time block. The data flow and quality checks in the production of this data set are described as well as the format of the data tapes and the accompanying shipping documents.

  7. Progress Toward Demonstrating a High Performance Optical Tape Recording Technology

    NASA Technical Reports Server (NTRS)

    Oakley, W. S.

    1996-01-01

    This paper discusses the technology developments achieved during the first year of a program to develop a high performance digital optical tape recording device using a solid state, diode pumped, frequency doubled green laser source. The goal is to demonstrate, within two years, useful read/write data transfer rates to at least 100 megabytes per second and a user capacity of up to one terabyte per cartridge implemented in a system using a '3480' style mono-reel tape cartridge.

  8. Non-elastic taping, but not elastic taping, provides benefits for patients with knee osteoarthritis: systemic review and meta-analysis.

    PubMed

    Ouyang, Jin-Han; Chang, Kwang-Hwa; Hsu, Wen-Yen; Cho, Yen-Ting; Liou, Tsan-Hon; Lin, Yen-Nung

    2017-06-01

    To determine whether therapeutic taping, which includes elastic (Kinesio tape) and non-elastic (Leukotape) taping, is superior to control taping in improving pain and functions for patients with knee arthritis. To understand whether both elastic and non-elastic taping are beneficial. We searched the PubMed and Scopus databases from their earliest record to 31 May 2017 for randomized controlled and cross-over studies that used taping to treat knee osteoarthritis. We extracted the mean differences and SD between baseline and posttreatment for selected outcomes measured in the experimental and control groups for subsequent meta-analyses. In total, 11 studies were included in the review. Of which, five Leukotaping and five Kinesio taping studies involving 379 participants were used in the meta-analysis. PEDro scores of the Leukotaping and Kinesio taping studies were 4.2 and 7.8, respectively. Overall, therapeutic taping exhibited significantly greater pain reduction than control taping with a significant weighted mean difference of 12.8 mm on a 0- to 100-mm visual analogue scale. Compared to control taping, Leukotaping produced a significant weighted mean difference of 11.6 mm regarding pain with a large effect size of 0.89 and I(2) = 0%, while Kinesio taping produced a non-significant weighted mean difference of 12.1 mm and I(2) = 93%. Leukotaping also exhibited a large and significant standard mean difference of 0.82, while Kinesio taping exhibited a non-significant standard mean difference of 1.34 regarding climbing stairs and stepping. Therapeutic taping seemed to be superior to control taping in pain control for knee osteoarthritis. Non-elastic taping, but not elastic taping, provides benefits in pain reduction and functional performance.

  9. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  10. Tape blisters after hip surgery: can they be eliminated completely?

    PubMed

    Koval, Kenneth J; Egol, Kenneth A; Hiebert, Rudi; Spratt, Kevin F

    2007-05-01

    It was recently reported that use of a perforated, stretchable cloth tape instead of silk tape reduced the incidenc of postoperative blisters around the hip from 41% to 10%. The present prospective randomized study was conducted to determine whether use of spica bandage (vs the cloth tape) could further reduce or eliminate the incidence of these blisters. Patients were randomized to 2 treatmen groups: perforated, stretchable cloth tape (Hypafix; Smit & Nephew, Memphis, Tenn) and elastic spica bandage tha was started at the lower thigh and was extended aroun the hip and abdomen. After surgery, cloth tape or spic bandage was applied over the postoperative dressing, with care taken not to produce skin tension. At the first dressing change, presence or absence of blisters was recorded, along with their number, size, location, and type. All subsequent dressing changes were done much as they wer at surgery, using the assigned type of dressing. Presence or absence of blisters was recorded at each subsequent dressing change. Two hundred ninety-four patients (300 hips) were enrolled. Twenty-two (7.33%) of the 300 hips developed a blister. Risk for developing a blister was 10% with the cloth tape versus 4.67% with the elastic spica bandage (P < .09). Surgery type (arthroplasty vs open reduction and internal fixation [ORIF], P < .03) and surgery duration (P < .05) had more of an effect on postoperative blister formation than dressing type.

  11. Magnetization loss for stacks of ReBCO tapes

    NASA Astrophysics Data System (ADS)

    Bykovsky, N.; De Marzi, G.; Uglietti, D.; Bruzzone, P.; Muzzi, L.

    2017-02-01

    The AC loss measurements of the high temperature superconductor (HTS) cable prototype in the EDIPO test facility motivated detailed investigations of the loss contributions from the tape, strand and cable stages of the HTS fusion conductor design proposed at the Swiss Plasma Center. As an initial step of the task, magnetization tests of soldered stacks of HTS tapes were carried out at temperatures of 5 and 77 {{K}} and magnetic fields up to 12 {{T}} using the vibrating sample magnetometer technique. The influence on the magnetization loss of the number of tapes, width of the tape, field’s orientation and tape’s manufacturer is studied experimentally performing both the major and minor magnetization loops with different ramp rates of the applied magnetic field. In order to validate the test results, a numerical model is developed and presented in this work. From the numerical model we also deduced an analytical approach for the magnetization loss in the stacks of tapes with arbitrary number of tapes in the critical state model. Comparison between the measured and estimated magnetization loss of the cable prototypes is reported as well.

  12. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  13. Fabrication and characterization of Hg(Tl) HTSC tapes

    NASA Astrophysics Data System (ADS)

    Asthana, Anjana; Srivastava, O. N.

    1998-02-01

    0953-2048/11/2/013/img1 (x = 0.1, 0.2, 0.3, 0.5 and 0.8) HTSC tapes have been synthesized through the reaction of a mixture of Hg-Tl vapour with the precursor tapes 0953-2048/11/2/013/img2 (fabricated by the doctor blade tape casting technique) in an evacuated sealed quartz tube at 0953-2048/11/2/013/img3 for 12 h. The Hg(Tl) tape having composition 0953-2048/11/2/013/img4 is found to possess 0953-2048/11/2/013/img5 and transport current density 0953-2048/11/2/013/img6 (20 K). The observed 0953-2048/11/2/013/img7 and 0953-2048/11/2/013/img8 seem to be the highest reported so far for Hg(Tl)-Ba-Ca-Cu-O HTSC tapes. SEM explorations of the surface have revealed the occurrence of layered spiral growth features for the Hg(Tl) HTSC tapes.

  14. The effect of Kinesio Taping on handgrip strength

    PubMed Central

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18–30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values. PMID:25931682

  15. The effect of Kinesio Taping on handgrip strength.

    PubMed

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  16. Development of the industrial scale Ag/Bi-2223 tape

    NASA Astrophysics Data System (ADS)

    Fujikami, J.; Kaneko, T.; Ayai, N.; Kobayashi, S.; Hayashi, K.; Takei, H.; Sato, K.

    2002-10-01

    Tape shaped silver-sheathed Bi-2223 superconducting wire (Bi-2223 tape) technologies are reported. The operations of superconducting apparatus at liquid nitrogen temperature or at 20-30 K are expectable by using Bi-2223-tapes. The reduction of AC loss at 77 K is critical for power cable application, such as electric transmission cable and transformer prototypes. Thinning of the tape thickness and twisting of the tapes are the main techniques for the reduction of AC loss. For the power transformer application, coating technology is investigated to have good electrical insulation. The refrigerator-cooled magnet for industrial use is another example of the superconducting apparatus operating at 20-30 K. It is important to know the critical current density dependence on the applied magnetic field ( Jc- B dependence) for the magnet design. It was confirmed that Jc of the Bi-2223 tape, which shows Jc=30 kA/cm 2 at 77 K in self-magnetic field, exceeds 100 kA/cm 2 at 20 K, and 1 T.

  17. Longitudinal magnetization loss in twisted multifilamentary Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Amemiya, N.; Rabbers, J.-J.; Krooshoop, B. E.; ten Haken, B.; ten Kate, H.; Ayai, N.; Hayashi, K.

    2002-08-01

    Multifilamentary Bi2223 tapes are exposed to the longitudinal magnetic field as well as the transverse one in some electrical power apparatuses such as multilayer power transmission cables. Here, we define the longitudinal and transverse magnetic fields as the field components parallel and perpendicular to the tape axis, respectively. If the filament-bundle is twisted, it can couple to the AC longitudinal magnetic field to generate the longitudinal magnetization loss. Furthermore, the AC transport current flowing spirally in the twisted filament-bundle possibly influences the longitudinal magnetization. The longitudinal magnetization loss was measured in a twisted multifilamentary Bi2223 tape exposed to longitudinal magnetic field and carrying the transport current. The measured longitudinal magnetization loss in the twisted tape exposed to the longitudinal magnetic field is larger than that in another untwisted tape. Supplying the AC transport current changes the longitudinal magnetization loss in the twisted tape exposed to the AC longitudinal magnetic field. The influence of the transport current depends on the phase relation between the longitudinal magnetic field and the transport current. If their phase difference is 0°, the longitudinal magnetization loss decreases remarkably with increasing amplitude of the transport current. It means that the change in the current distribution due to the transport current results in the decrease in the power flow from the magnet power supply. But, a preliminary measurement of the transport loss shows that the total loss increases with increasing transport current.

  18. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  19. The effect of high-Dye and low-Dye taping on rearfoot motion.

    PubMed

    Keenan, A M; Tanner, C M

    2001-05-01

    High-Dye and low-Dye taping are commonly used by clinicians to treat a variety of foot and ankle pathologies, particularly those associated with excessive rearfoot pronation. While the effects of taping on end range of motion have been extensively studied, relatively little is understood about the effect of the two styles of taping on rearfoot motion. Eighteen participants were analyzed in three conditions: 1) barefoot, 2) with high-Dye taping, and 3) with low-Dye taping. Two-dimensional motion of the rearfoot was assessed for each condition. The results indicated maximum inversion was increased with both high-Dye and low-Dye taping as compared with no taping. Only high-Dye taping, however, significantly reduced the maximum eversion of the rearfoot. The results suggest that high-Dye taping is an appropriate taping choice when control of eversion of the rearfoot is desired.

  20. Endotracheal tube fixation methods for optimal stability: a comparison of adhesive tape, suture, and tape-suture fixation.

    PubMed

    Farbod, Frank; Tuli, Puneet; Robertson, Bernard F; Jackson, Ian T

    2010-07-01

    Accidental extubation of an intubated patient is a serious consideration in the surgical patient. Adequate fixation in the intubated patient is essential to prevent potentially life-threatening complications. Several methods of endotracheal tube fixation have been described in the literature. In this study, we examine 3 common methods of fixation: adhesive tape alone, suture, and tape-suture. Testing occurred in a laboratory setting with 2 fresh cadavers. Endotracheal tubes were inserted, using the methods of fixation in question. We subjected each fixation technique to progressively increasing weight to determine which technique is most resistant to accidental removal. We found that fixation of the tube by combining tape around the tube with a suture through the tape is the best noninvasive technique of the 3 methods evaluated in cases where movement of the head is anticipated.

  1. Use of liquid nitrogen to remove duct tape from a homicide victim.

    PubMed

    Stephens, B G; Nazareno, G; Block, M; Hnatow, P

    1999-06-01

    Removal of duct tape or similar adhesive products from a homicide victim may be facilitated by rapidly chilling the tape surface with liquid nitrogen. Physical separation of tape layers can be performed using the same technique. Cyanoacrylate glue (i.e., "super-glue") may be used to preserve fingerprints on the outer surface of the tape for recovery, or other techniques may be used to recover fingerprints from the outer surface prior to tape removal.

  2. Effects of water-vapor on friction and deformation of polymeric magnetic media in contact with a ceramic oxide

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity (water-vapor) in nitrogen on the friction and deformation behavior of magnetic tape in contact with a Ni-Zn ferrite spherical pin were studied. The coefficient of friction is markedly dependent on the ambient relative humidity. In elastic contacts the coefficient of friction increased linearly with increasing humidity; it decreased linearly when humidity was lowered. This effect is the result of changes in the chemistry and interaction of tape materials such as degradation of the lubricant. In plastic contacts there was no effect of humidity on friction below 40 percent relative humidity. There is no effect on friction associated with the breakthrough of the adsorbed water-vapor film at the interface of the tape and Ni-Zn ferrite. The coefficient of friction, however, increased rapidly with increasing relative humidity above 40 percent in plastic contacts.

  3. Effects of balance taping using kinesiology tape in a patient with moderate hallux valgus: A case report.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-11-01

    Hallux valgus, an increased angle of lateral deviation in the big toe, can cause pain and difficulties in balancing and walking. This study aimed to investigate the effects of balance taping using elastic therapeutic tape on moderate hallux valgus. When she walked with shoes, she complained of pain over the medial eminence of the hallux metatarsophalangeal (MTP) joint. Balance taping using kinesiology tape was applied for 3 months (average, 16hours/d) to both big toes of a 26-year-old woman with moderate hallux valgus. On the right side, the hallux valgus angle (HVA) decreased from 21° to 14° and the intermetatarsal angle (IMA) decreased from 15° to 14.5°. On the left side, the HVA decreased from 22° to 11° and the IMA decreased from 15° to 12°. Furthermore, the patient was able to walk long distances in shoes without pain in the medial eminence of the hallux metatarsophalangeal joint. This study suggested that repeated balance taping with kinesiology tape could be used as a complementary treatment method for moderate hallux valgus.

  4. Accelerated aging studies and environmental stability of prototype tamper tapes

    SciTech Connect

    Wright, B.W.; Wright, C.W.; Bunk, A.R.

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  5. Kinesio Tape and Shoulder-Joint Position Sense.

    PubMed

    Aarseth, Lindsay M; Suprak, David N; Chalmers, Gordon R; Lyon, Lonnie; Dahlquist, Dylan T

    2015-08-01

    Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Cross-sectional study. University laboratory. A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω(2) = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω(2) = .002), position (ω(2) = .072), and tape by position (ω(2) = .027). At 90° of elevation, shoulder JPS was impaired by the application of KT.

  6. Kinesio Tape and Shoulder-Joint Position Sense

    PubMed Central

    Aarseth, Lindsay M.; Suprak, David N.; Chalmers, Gordon R.; Lyon, Lonnie; Dahlquist, Dylan T.

    2015-01-01

    Context Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. Objective To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Intervention(s) Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. Main Outcome Measure(s) We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Results Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω2 = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω2 = .002), position (ω2 = .072), and tape by position (ω2 = .027). Conclusions At 90° of elevation, shoulder JPS was impaired by the application of KT. PMID:26090707

  7. Molecularly imprinted polymer monolith containing magnetic nanoparticles for the stir-bar sorptive extraction of triazines from environmental soil samples.

    PubMed

    Díaz-Álvarez, Myriam; Turiel, Esther; Martín-Esteban, Antonio

    2016-10-21

    In this work, novel molecularly imprinted stir-bars based upon the entrapment of modified magnetic nanoparticles within an imprinted polymer monolith is developed for stir-bar sorptive extraction (SBSE). Firstly, magnetic nanoparticles were surface modified with oleic acid followed by encapsulation inside a silica network. Then, vinyl-groups were grafted onto the particles surface for the subsequent copolymerization with the imprinting polymerization mixture using a glass vial insert as a mold. As a result, the obtained imprinted monolith presented magnetic properties allowing its use as magnetic stir-bar. Variables affecting both polymer morphology (i.e., amount of magnetic nanoparticles, polymerization time) and binding-elution conditions of target analytes (i.e., solvents, time) was carefully optimized. Optimum imprinted stir-bars were evaluated for the SBSE of triazines in soil sample extracts. Recoveries, at 16ngg(-1) concentration level, ranged from 2.4 to 8.7% with relative standard deviations lower than 15% (n=3). Although low recoveries were obtained, the high selectivity provided by the new molecularly imprinted stir-bars allowed reaching detection limits below 7.5ngg(-1) by liquid chromatography coupled to UV detection.

  8. A model-based evaluation of sorptive reactivities of hydrous ferric oxide and hematite for U(VI).

    PubMed

    Jang, Je-Hun; Dempsey, Brian A; Burgos, William D

    2007-06-15

    The sorption of uranyl onto hydrous ferric oxide (HFO) or hematite was measured by discontinuously titrating the suspensions with uranyl at pH 5.9, 6.8, and 7.8 under Pco2 = 10(-35)atm (sorption isotherms). Batch reactors were used with equilibration times up to 48 days. Sorption of 1 microM uranyl onto HFO was also measured versus pH (sorption edge). A diffuse double layer surface complexation model was calibrated by invoking three sorption species that were consistent with spectroscopic evidence for predominance of bidentate complexes at neutral pH and uranyl-carbonato complexes: > SOH:UO2OH(+1), (> SO)2: UO2CO3(-2), and (> SO)2:(UO2)3(OH)5(-1). The model was consistent with previously published isotherm and edge data. The model successfully predicted sorption data onto hematite, only adjusting for different measured specific surface area. Success in application of the model to hematite indicates that the hydrated surface of hematite has similar sorptive reactivity as HFO.

  9. A fast stir bar sorptive extraction method for the analysis of geosmin and 2-methylisoborneol in source and drinking water.

    PubMed

    Bauld, T; Teasdale, P; Stratton, H; Uwins, H

    2007-01-01

    The presence of unpleasant taste and odour in drinking water is an ongoing aesthetic concern for water providers worldwide. The need for a sensitive and robust method capable of analysis in both natural and treated waters is essential for early detection of taste and odour events. The purpose of this study was to develop and optimise a fast stir bar sorptive extraction (SBSE) method for the analysis of geosmin and 2-methylisoborneol (MIB) in both natural water and drinking water. Limits of detection with the optimised fast method (45 min extraction time at 60 degrees C using 24 microL stir bars) were 1.1 ng/L for geosmin and 4.2 ng/L for MIB. Relative standard deviations at the detection limits were under 17% for both compounds. Use of multiple stir bars can be used to decrease the detection limits further. The use of 25% NaCl and 5% methanol sample modifiers decreased the experimental recoveries. Likewise, addition of 1 mg/L and 1.5 mg/L NaOCI decreased the recoveries and this effect was not reversed by addition of 10% thiosulphate. The optimised method was used to measure geosmin concentrations in treated and untreated drinking water. MIB concentrations were below the detection limits in these waters.

  10. Evaluation of low-cost disposable polymeric materials for sorptive extraction of organic pollutants in water samples.

    PubMed

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Rodríguez, Isaac; Cela, Rafael; Möder, Monika

    2012-02-24

    The capabilities of four commercially available and low cost polymeric materials for the extraction of polar and non-polar contaminants (logK(ow)=-0.07-6.88, from caffeine to octocrylene, respectively) from water samples was compared. Tested sorbents were polyethersulphone, polypropylene and Kevlar, compared to polydimethylsiloxane as reference material. Parameters that affect the extraction process such as pH and ionic strength of the sample, extraction time and desorption conditions were thoroughly investigated. A set of experimental partition coefficients (K(pw)), at two different experimental conditions, was estimated for the best suited materials and compared with the theoretical octanol-water (K(ow)) partition coefficients of the analytes. Polyethersulphone displayed the largest extraction yields for both polar and non-polar analytes, with higher K(pw) and lower matrix effects than polydimethylsiloxane and polypropylene. Thus, a sorptive microextraction method, followed by large volume injection (LVI) gas chromatography-tandem mass spectrometry (GC-MS/MS), was proposed using the former sorbent (2 mg) for the simultaneous determination of model compounds in water samples. Good linearity (>0.99) was obtained for most of the analytes, except in the case of 4-nonylphenol (0.9466). Precision (n=4) at 50 and 500 ng L(-1) levels was in the 2-24% and limits of detection (LODs) were in the 0.6-25 ng L(-1) range for all the analytes studied.

  11. Preparation a new sorbent based on polymeric ionic liquid for stir cake sorptive extraction of organic compounds and inorganic anions.

    PubMed

    Huang, Xiaojia; Wang, Yulei; Hong, Qiuyun; Liu, Yi; Yuan, Dongxing

    2013-11-01

    A new multi-interaction sorbent (MIS) based on polymeric ionic liquid was prepared and used as extractive medium of stir cake sorptive extraction (SCSE). In the presence of dimethyl sulfoxide, an ionic liquid, 1-vinylbenzyl-3-methylimidazolium chloride was used as monomer to copolymerize in situ with divinylbenzene to form the MIS. The influences of the content of monomer and the porogen solvent in the polymerization mixture on the extraction performance were investigated thoroughly. The MIS was characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. Parabens and aromatic amines were used to investigate the extraction performance of MIS-SCSE for apolar and strongly polar analytes, respectively. The extraction parameters for parabens and aromatic amines were optimized. At the same time, simple and sensitive analytical methods for parabens and aromatic amines in real samples were developed by the combination of MIS-SCSE and HPLC/DAD. Some inorganic anions, such as F(-), Br(-), NO3(-), PO4(3-) and SO4(2-), were used to test the extraction performance of MIS-SCSE for anions. Results indicated that mechanism involved in the extraction of MIS is the multi-interaction modes including π-π, hydrophobic, hydrogen-bonding, dipole-dipole and anion-exchange interactions. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Application of linear free energy relationships to characterizing the sorptive characteristics of organic contaminants on organoclays from water.

    PubMed

    Zhu, Runliang; Chen, Wangxiang; Liu, Yun; Zhu, Jianxi; Ge, Fei; He, Hongping

    2012-09-30

    Linear free energy relationships (LFERs) were applied to investigate the sorptive characteristics of organic contaminants (OCs) on organoclays from water. Three cetyltrimethylammonium modified montmorillonites (C-Mts) were selected as representative organoclays. The sorption coefficients (logK(oc)) of OCs on the C-Mts were calculated according to the results of batch sorption experiments. Then the LFER equations for OC sorption on C-Mts from water were developed. The results of this study showed that compared with bulk water, water saturated C-Mts are more polarizable, less polar and cohesive, and have stronger H-bond acceptor capacities and weaker H-bond donor capacities. The primary driving forces for the sorption of OCs from water to C-Mts can be ascribed to the weaker cohesive characteristics of C-Mts as well as the stronger nonspecific Van der Waals interaction between OCs and C-Mts. With increasing CTMA loading amount, the interaction between OCs and C-Mts increases whereas the C-Mts become more cohesive. Consequently, the sorption capacity of C-Mts first increases with CTMA loading amount and then decreases with further increased loading amount.

  13. Capillary electrophoresis for analyzing pesticides in fruits and vegetables using solid-phase extraction and stir-bar sorptive extraction.

    PubMed

    Juan-García, Ana; Picó, Yolanda; Font, Guillermina

    2005-05-06

    Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) in combination with micellar electrokinetic chromatography (MEKC)--diode array detection (DAD) were compared for the simultaneous extraction of acrinathrin, bitertanol, cyproconazole, fludioxonil, flutriafol, myclobutanil, pyriproxyfen, and tebuconazole in lettuce, tomato, grape, and strawberry. Selectivity and resolution of the MEKC procedure were studied changing the pH and the molarity of the buffer, the type and the concentration of surfactant, and the methanol content in the mobile phase. A buffer consisting of 6 mM sodium tetraborate decahydrate with 75 mM of cholic acid sodium solution (pH 9.2) gave the best results. Linearity, extraction efficiencies and limits of quantitation (LOQs) of both extraction methods were compared. The recoveries obtained by SPE ranged from 40 to 106% with relative standard deviations (R.S.D.s) from 10 to 19% whereas by the SBSE method, the recoveries were 12-47% and the R.S.D.s 3-17%. The LOQs were much better by SPE (0.2-0.5 mg kg(-1) depending on the processed sample amount) than those obtained by SBSE (1 mg kg(-1) for each compound). Advantages and disadvantages of both procedures are also discussed. As SPE is more robust, rapid, and sensitive than SBSE, its application in combination with MEKC is recommended because provided LOQs below the MRLs established, which is not always attained by SBSE.

  14. Determination of 11 quinolones in bovine milk using immunoaffinity stir bar sorptive microextraction and liquid chromatography with fluorescence detection.

    PubMed

    Yao, Kai; Zhang, Wei; Yang, Linyan; Gong, Jianfang; Li, Liuan; Jin, Tianming; Li, Cun

    2015-10-15

    A sensitive, selective and reproducible immunoaffinity stir bar sorptive microextraction (SBSME) coupled with liquid chromatography-fluorescence method for determination of 11 quinolones (QNs) in bovine milk was developed and validated. It is first report of a broad-specificity monoclonal antibody to QNs that has been immobilized to glass bar for preparation of a re-usable immunoaffinity stir bar. Analytes were extracted by placing stir bar in milk and shaking on a rotary shaker for 30min at 30rpm, followed by liquid chromatography and fluorescence detection. The newly developed method has limits of detection for each QN from 0.05 to 0.1ng/g with intra-day and inter-day precision ranging from 3.2 to 11.9% and from 5.2 to 12.5%, respectively. This allowed us to quantitatively analyze drugs in bovine milk with the advantage of significantly simplified sample preparation. The proposed method was successfully applied to the bovine milk samples analyses with QNs, demonstrating its rare application in animal food safety analysis.

  15. Influence of polydimethylsiloxane outer coating and packing material on analyte recovery in dual-phase headspace sorptive extraction.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Sgorbini, Barbara; David, Frank; Sandra, Pat; Rubiolo, Patrizia

    2007-09-14

    Dual phase twisters (DP twisters), consisting of a polydimethylsiloxane (PDMS) outer coating and a second complementary (ad)sorbent as inner packing, have recently been shown to extend the applicability of headspace sorptive extraction (HSSE). In comparison to HSSE using PDMS only, the recovery of analytes from the headspace of a solid or liquid matrix is increased by combining the concentration capabilities of two sampling materials operating on different mechanisms (sorption and adsorption). This study compares the performance of DP twisters consisting of different PDMS outer coatings and different packing materials, including Tenax GC, a bisphenol-PDMS copolymer, Carbopack coated with 5% of Carbowax and beta-cyclodextrin, for the analysis of the headspace of roasted Arabica coffee, dried sage leaves and an aqueous test mixture containing compounds with different water solubility, acidity, polarity and volatility as test samples. In general, DP twisters showed a higher concentration capability than the corresponding conventional PDMS twisters for the analytes considered. The highest recoveries were obtained with DP twisters consisting of 0.2mm thick PDMS coating combined with Tenax GC, a bisphenol-PDMS copolymer and Carbopack coated with 5% of Carbowax as inner adsorption phase.

  16. Determination of breath gas composition of lung cancer patients using gas chromatography/mass spectrometry with monolithic material sorptive extraction.

    PubMed

    Ma, Wen; Gao, Peng; Fan, Jun; Hashi, Yuki; Chen, Zilin

    2015-06-01

    A gas chromatographic-mass spectrometric method with monolithic material sorptive extraction (MMSE) pretreatment was developed to determine the breath gas composition in lung cancer patients. MonoTrap silica monolithic and hybrid adsorbent was selected as the extraction medium during MMSE, given its strong capacity to extract volatile organic compounds (VOC) from exhaled gas. Under the appropriate conditions, high extraction efficiency was achieved. Using the selected ion-monitoring mode, the limit of detection (signal-to-noise ratio 3) for the benzene series was 0.012-2.172 ng L(-1) . The limit of quantitation (signal-to-noise ratio, 10) was 0.042-7.24 ng L(-1) . The linearity range of the method was 4-400 ng L(-1) . Average recovery of the benzene series at lower concentrations was 65-74% (20 ng L(-1) ). The relative standard deviation of benzene series contents determined within the linear range of detection was <10% of the mean level determined. Our proposed method is simple, rapid and sensitive, and can be competently applied to determine the breath gas composition of lung cancer patients. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Determination of dimethyl trisulfide in rabbit blood using stir bar sorptive extraction gas chromatography-mass spectrometry.

    PubMed

    Manandhar, Erica; Maslamani, Nujud; Petrikovics, Ilona; Rockwood, Gary A; Logue, Brian A

    2016-08-26

    Cyanide poisoning by accidental or intentional exposure poses a severe health risk. The current Food and Drug Administration approved antidotes for cyanide poisoning can be effective, but each suffers from specific major limitations concerning large effective dosage, delayed onset of action, or dependence on enzymes generally confined to specific organs. Dimethyl trisulfide (DMTS), a sulfur donor that detoxifies cyanide by converting it into thiocyanate (a relatively nontoxic cyanide metabolite), is a promising next generation cyanide antidote. Although a validated analytical method to analyze DMTS from any matrix is not currently available, one will be vital for the approval of DMTS as a therapeutic agent against cyanide poisoning. Hence, a stir bar sorptive extraction (SBSE) gas chromatography - mass spectrometry (GC-MS) method was developed and validated for the analysis of DMTS from rabbit whole blood. Following acid denaturation of blood, DMTS was extracted into a polydimethylsiloxane-coated stir bar. The DMTS was then thermally desorbed from the stir bar and analyzed by GC-MS. The limit of detection of DMTS using this method was 0.06μM with dynamic range from 0.5-100μM. For quality control standards, the precision, as measured by percent relative standard deviation, was below 10%, and the accuracy was within 15% of the nominal concentration. The method described here will allow further investigations of DMTS as a promising antidote for cyanide poisoning.

  18. Application of a stir bar sorptive extraction method for the determination of volatile compounds in different grape varieties.

    PubMed

    Vasile-Simone, Giuseppe; Castro, Remedios; Natera, Ramón; Masino, Francesca; Barroso, Carmelo G; Durán-Guerrero, Enrique

    2017-02-01

    Stir bar sorptive extraction (SBSE) has been employed for the analysis of aroma compounds directly from Spanish and Italian grape extracts. The extraction conditions have been optimized using a statistical approach, obtaining results that improve the current state of the art. The proposed analytical conditions were: sample volume 40 mL, extraction time 80 min, 25% (w/v) NaCl and stirring speed 750 rpm using 20 mm × 0.5 mm stir bars. Performance characteristics of the SBSE procedure were further studied and showed correlation coefficients, detection and quantification limits, linear ranges, recoveries and precision values adequate for analysing these compounds in grapes. Twenty-four grape varieties (aromatic and non-aromatic) were analysed. Statistically significant differences (P < 0.05) according to geographical origin were found, being derived mainly from the terpenoid content. By principal component analysis it was possible to note that the terpenoids were more effective in the separation of the non-aromatic samples, showing negative and positive scores for Italian and Spanish grapes, respectively. For non-aromatic grape varieties, the factor 'geographic location' was the most significant, thus corroborating the high influence of this parameter on the volatile composition of grapes and therefore on the genuineness of wines. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  19. Numerical methods for improving sensitivity analysis and parameter estimation of virus transport simulated using sorptive-reactive processes

    USGS Publications Warehouse

    Barth, G.; Hill, M.C.

    2005-01-01

    Using one- and two-dimensional homogeneous simulations, this paper addresses challenges associated with sensitivity analysis and parameter estimation for virus transport simulated using sorptive-reactive processes. Head, flow, and conservative- and virus-transport observations are considered. The paper examines the use of (1) observed-value weighting, (2) breakthrough-curve temporal moment observations, and (3) the significance of changes in the transport time-step size. The results suggest that (1) sensitivities using observed-value weighting are more susceptible to numerical solution variability, (2) temporal moments of the breakthrough curve are a more robust measure of sensitivity than individual conservative-transport observations, and (3) the transport-simulation time step size is more important than the inactivation rate in solution and about as important as at least two other parameters, reflecting the ease with which results can be influenced by numerical issues. The approach presented allows more accurate evaluation of the information provided by observations for estimation of parameters and generally improves the potential for reasonable parameter-estimation results. ?? 2004 Elsevier B.V. All rights reserved.

  20. Sorptive physiologically based extraction of contaminated solid matrices: incorporating silicone rod as absorption sink for hydrophobic organic contaminants.

    PubMed

    Gouliarmou, Varvara; Collins, Chris D; Christiansen, Ellen; Mayer, Philipp

    2013-01-15

    The oral bioaccessibility of soil contaminants is increasingly assessed with physiologically based extraction tests (PBETs): the contaminant fraction that is desorbed into simulated digestive fluids is measured and classified as bioaccessible. However, this approach can lead to underestimations if the capacity of the fluids is insufficient to provide infinite sink conditions. Desorption will then progressively decrease and finally stop when equilibrium between soil and medium is reached. To circumvent this artifact, we incorporated a silicone rod as an absorption sink into the PBET to continuously absorb mobilized contaminants and maintain the desorption gradient. Polycyclic aromatic hydrocarbons served as model contaminants and the colon extended PBET as the extraction model. The inclusion of the silicone rod sink (1) increased the extraction capacity of the test by orders of magnitude, (2) ensured near infinite sink conditions, and (3) allowed for simple back-extraction of PAHs for their quantification by GC-MS. The silicone rod provided fast enrichment when applied to the stomach and small intestine compartment, but was somewhat slower in the richer colon compartment. Finally, the sorptive-PBET was applied to wood soot and a kindergarten soil. The present article provides the basis for how an absorption sink can be integrated into PBET models.

  1. Development of a new stir bar sorptive extraction method for the determination of medium-level volatile thiols in wine.

    PubMed

    Elpa, Decibel; Durán-Guerrero, Enrique; Castro, Remedios; Natera, Ramón; Barroso, Carmelo G

    2014-07-01

    A fast, simple, and reliable analytical method for the determination of medium-level volatile thiols in wines is presented. Stir bar sorptive extraction using ethylene glycol-silicone coated stir bars has been used in combination with thermal desorption gas chromatography with mass spectrometry for the analysis of 4-mercapto-4-methylpentan-2-one, 2-furanmethanethiol, 3-mercaptohexyl acetate, and 3-mercaptohexanol in wine. Optimization of the extraction technique was performed using a two-level fractional factorial design. For the extraction step, the optimum conditions were: Ethylene glycol and silicone coated stir bars, pH at 3.5, sample volume of 25 mL, extraction time of 90 min, NaCl content 4.0 g, and stirring speed at 500 rpm. The optimized method achieved good linearity for all studied compounds (r(2) > 0.995) and it provided detection limits of 21.52, 0.36, 0.73, and 2.55 μg/L for 4-mercapto-4-methylpentan-2-one, 2-furanmethanethiol, 3-mercaptohexyl acetate, and 3-mercaptohexanol, respectively. It was repeatable, with precisions lower than 18% relative standard deviation for both intraday and interday repeatability. The developed procedure is suitable for the determination of these kinds of compounds when they are present at medium concentration levels. It was finally applied to real wine samples with negative aroma derived from the high concentration levels of these compounds. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Ion-pair sorptive extraction of perfluorinated compounds from water with low-cost polymeric materials: polyethersulfone vs polydimethylsiloxane.

    PubMed

    Villaverde-de-Sáa, Eugenia; Racamonde, Inés; Quintana, José Benito; Rodil, Rosario; Cela, Rafael

    2012-08-31

    A method for the determination of seven perfluorinated carboxylic acids and perfluorooctane sulphonate (PFOS) in aqueous samples using low-cost polymeric sorptive extraction as sample preparation technique, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination has been developed and validated. Simplicity of the analytical procedure, low volume of solvent and sample required, low global price and a good selectivity providing cleaner extracts are the main advantages of this extraction technique. Polydimethylsiloxane (PDMS) and polyethersulfone (PES) materials were evaluated and compared to achieve the best extraction efficiencies. Hence, different variables have been optimized, viz.: sample pH, concentration of an ion-pairing agent (tetrabutylammonium), ionic strength, sample volume, extraction time, desorption solvent volume, desorption time and the need for auxiliary desorption techniques (sonication). Overall, PES leaded to a better sensitivity than PDMS, particularly for the most polar compounds, reaching detection limits (LODs) in the 0.2-20 ng L(-1) range. The precision of the method, expressed as relative standard deviation (RSD), was lower than 16%. Finally, the PES material was employed for the analysis of sea, sewage and fresh water samples. Perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were detected in all the analyzed influent samples reaching levels of up to 401 ng L(-1). In surface water, perfluorohexanoic acid (PFHxA) exhibited the highest concentrations, up to 137 ng L(-1).

  3. The NT digital micro tape recorder

    NASA Technical Reports Server (NTRS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  4. The NT digital micro tape recorder

    NASA Technical Reports Server (NTRS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  5. AC transport current losses of multifilamentary Bi(2223) tapes with varying filament geometries

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Däumling, M.; Quilitz, M.; Goldacker, W.

    1998-02-01

    We have measured the ac transport current loss of eight different Bi(2223) tapes with varying filament geometries in the frequency range from 13 to 500 Hz at 77 K. The investigated tapes have an Ag sheath (i.e. 37 or 703 filaments) or a modified sheath using AgMg. Furthermore tapes with novel geometries such as multifilamentary wire-in-tube (WIT) tapes and jelly-roll tapes have been studied. In addition we have investigated twisted tapes with a twist-pitch of 1.4 cm in the 37 filamentary Ag and the 85 filamentary AgMg tapes. To compare these tapes with different Ic values we calculated the loss factors of the tapes. We find that all the loss factors lay within the limits given for an elliptical or a strip like conductor. Furthermore we find differences in the loss factors due to the filament geometries.

  6. Microstructural evolution at the initial stages of annealing in a Bi-2223 multifilament tape

    NASA Astrophysics Data System (ADS)

    Liu, Y. L.; Grivel, J.-C.; Wang, W. G.; Poulsen, H. F.

    2001-11-01

    The microstructural evolution at the initial stage of annealing in a multifilament Bi-2223 (2223) tape is studied in quenched samples using XRD, SEM and EDS. The annealing was carried out at 830 °C under reduced oxygen partial pressure. Samples were quenched in air upon reaching 830 °C, as well as after 1, 2, 5, 10, 30 and 52 h at 830 °C. It was found that the initial liquid formation was associated with alkaline-earth cuprate (AEC) particles such as (Ca,Sr)14Cu24Oz and (Ca,Sr)2CuO3. The liquid is rich of Pb and the AEC particles dissolve and supply Cu and Ca into the liquid through direct contact. The 2223 kinetics are well correlated with the structural parameters of liquid and AEC particles. During the first hour the liquid activity is confined to the neighbourhood of AEC particles and the rate of 2223 formation is very low. Between 2 and 10 h the liquid amount increases and the size (measured in tape plane) is comparable with the particle spacing indicating a liquid activity on an overall scale and sufficient feeding of Cu and Ca. Consequently, the 2223 develops at a fast rate. After 10 h the liquid amount is decreased, the particle spacing is far larger than the liquid size and the rate of 2223 formation slows down. The early 2223 forms as precipitates in the structure. The possible formation mechanisms are discussed.

  7. Proteobacteria, extremophiles and unassigned species dominate in a tape-like showerhead biofilm.

    PubMed

    Charnock, Colin; Nordlie, Anne-Lise

    2016-01-01

    The development of showerhead biofilms exposes the user to repeated contact with potentially pathogenic microbes, yet we know relatively little about the content of these aggregates. The aim of the present study was to examine the microbial content of tape-like films found protruding from a domestic showerhead. Culturing showed that the films were dominated by aerobic α- and β-proteobacteria. Three isolates made up almost the entire plate count. These were a Brevundimonas species, a metalophilic Cupriavidus species and a thermophile, Geobacillus species. Furthermore, it was shown that the Cupriavidus isolate alone had a high capacity for biofilm formation and thus might be the initiator of biofilm production. A clone library revealed the same general composition. However, half of the 70 clones analyzed could not be assigned to a particular bacterial phylum and of these 29 differed from one another by only 1-2 base pairs, indicating a single species. Thus both the culture dependent and culture independent characterizations suggest a simple yet novel composition. The work is important as the biofilm is fundamentally different in form (tape-like) and content from that of all previously reported ones, where variously Mycobacterium, Methylobacterium and Xanthomonas species have dominated, and extremophiles were not reported. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  8. Kinesiology tape does not facilitate muscle performance: A deceptive controlled trial.

    PubMed

    Poon, K Y; Li, S M; Roper, M G; Wong, M K M; Wong, O; Cheung, R T H

    2015-02-01

    Kinesiology tape (KinTape) is a therapeutic tape without much understanding of its mechanism. KinTape claims to increase cutaneous stimulation, which facilitates motor unit firing, and consequently improves functional performance; however these, benefits could be due to placebo effects. This study investigated the true effects of KinTape by a deceptive, randomized, and controlled trial. Thirty healthy participants performed isokinetic testing of three taping conditions: true facilitative KinTape, sham KinTape, and no KinTape. The participants were blindfolded during the evaluation. Under the pretense of applying adhesive muscle sensors, KinTape was applied to their quadriceps in the first two conditions. Normalized peak torque, normalized total work, and time to peak torque were measured at two angular speeds (60°/s and 180°/s) and analyzed with one-way repeated measures ANOVA. Participants were successfully deceived and they were ignorant about KinTape. No significant differences were found between normalized peak torque, normalized total work, and time to peak torque at 60°/s or 180°/s (p = 0.31-0.99) between three taping conditions. The results showed that KinTape did not facilitate muscle performance in generating higher peak torque, yielding a greater total work, or inducing an earlier onset of peak torque. These findings suggest that previously reported muscle facilitatory effects using KinTape may be attributed to placebo effects.

  9. The influence of tape type and of skin preparation on the force required to dislodge angiocatheters.

    PubMed

    Patel, N; Smith, C E; Pinchak, A C; Hancock, D E

    1994-08-01

    The study evaluated the effects of different techniques used to secure intravenous (i.v.) catheters. An angiocatheter attached to standard i.v. tubing was taped to human forearm using a standard taping method. A calibrated piezoelectric force transducer was attached to the i.v. tubing. The force applied along the longitudinal axis to pull out the taped catheter was measured and recorded on paper. Three tape types, Curity, Leukopor and Transpore, were evaluated alone, with benzoin skin pretreatment and with mastisol pretreatment. A randomized 3 x 3 block design with 20 replications per block was utilized, and a total of 180 pullout tests were performed on two adult volunteers. Without pretreatment, the forces required to dislodge catheters were (means +/- SEM) 46 +/- 2, 37 +/- 2 and 38 +/- 2 Newtons for Curity, Leukopor and Transpore tape, respectively. Corresponding values for mastisol pretreatment (64 +/- 1, 64 +/- 3 and 52 +/- 3 Newtons) were greater (P < 0.05) for each tape compared with benzoin (54 +/- 3, 53 +/- 2 and 40 +/- 2 Newtons) and no pretreatment. The most frequent failure mode for Transpore tape was by tape fracture, for Curity tape was by separation from the skin of tape and catheter as a single unit, and for Leukopor tape was by catheter separation while tape remained attached to skin (P < 0.001). The data suggest that the application of mastisol prior to taping i.v. catheters with Curity or Leukopor tape helps to minimize the risk of accidental dislodgement.

  10. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  11. Combinatorial study of ceramic tape-casting slurries.

    PubMed

    Liu, Zhifu; Wang, Yiling; Li, Yongxiang

    2012-03-12

    Ceramic tape-casting slurries are complex systems composed of ceramic powder, solvent, and a number of organic components. Conventionally, the development of ceramic tape-casting slurries is time-consuming and of low efficiency. In this work, combinatorial approaches were applied to screen the ethanol and ethyl-acetate binary solvent based slurry for ceramic green tape-casting. The combinatorial libraries were designed considering the variation of the amount of PVB (Poly vinyl-butyral) binder, polyethylene-400, and butyl-benzyl-phthalate plasticizers, and glyceryl triacetate dispersant. A parallel magnetic stirring process was used to make the combinatorial slurry library. The properties mapping of the slurry library was obtained by investigating the sedimentation and rheological characteristics of the slurries. The slurry composition was refined by scaling up the experiments and comparing the microstructure, mechanical property, and sintering behavior of green tapes made from the selected slurries. Finally, a kind of ethanol-ethyl acetate binary solvent based slurry system suitable for making X7R dielectric ceramic green tapes was achieved.

  12. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  13. Electric currents in REBaCuO superconducting tapes

    NASA Astrophysics Data System (ADS)

    Jirsa, M.; Rameš, M.; Ďuran, I.; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-04-01

    Magnetic induction and current transport techniques were employed to test the electromagnetic performance of 22 samples of superconducting REBaCuO tapes of several manufacturers with the aim to select the best candidates for wiring new generation superconducting magnets for fusion reactors. An extraordinary shape of pinning force density as a function of magnetic field was observed in ‘advanced pinning, AP’ SuperPower tapes. The induced currents enabled us to classify the tapes and show the best ones, at low temperatures and high magnetic fields on the one hand and at high temperatures and low magnetic fields on the other hand. Transport current experiments confirmed the results. Moreover, they provided information on current anisotropy, which appeared to be specific for each tape type. The present results formed a basis for the ongoing study of neutron irradiation impact on the tapes’ properties. The first experiment showed that neutron irradiation by the fluence of 2.1 E22 m-2 either enhances, reduces, or has no effect on the tape’s properties, according to the tape pinning structure.

  14. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  15. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  16. EDITORIAL: Close contact Close contact

    NASA Astrophysics Data System (ADS)

    Demming, Anna

    2010-07-01

    The development of scanning probe techniques, such as scanning tunnelling microscopy [1], has often been touted as the catalyst for the surge in activity and progress in nanoscale science and technology. Images of nanoscale structural detail have served as an invaluable investigative resource and continue to fascinate with the fantastical reality of an intricate nether world existing all around us, but hidden from view of the naked eye by a disparity in scale. As is so often the case, the invention of the scanning tunnelling microscope heralded far more than just a useful new apparatus, it demonstrated the scope for exploiting the subtleties of electronic contact. The shrinking of electronic devices has been a driving force for research into molecular electronics, in which an understanding of the nature of electronic contact at junctions is crucial. In response, the number of experimental techniques in molecular electronics has increased rapidly in recent years. Scanning tunnelling microscopes have been used to study electron transfer through molecular films on a conducting substrate, and the need to monitor the contact force of scanning tunnelling electrodes led to the use of atomic force microscopy probes coated in a conducting layer as studied by Cui and colleagues in Arizona [2]. In this issue a collaboration of researchers at Delft University and Leiden University in the Netherlands report a new device architecture for the independent mechanical and electrostatic tuning of nanoscale charge transport, which will enable thorough studies of molecular transport in the future [3]. Scanning probes can also be used to pattern surfaces, such as through spatially-localized Suzuki and Heck reactions in chemical scanning probe lithography. Mechanistic aspects of spatially confined Suzuki and Heck chemistry are also reported in this issue by researchers in Oxford [4]. All these developments in molecular electronics fabrication and characterization provide alternative

  17. Semifluorinated Alkylphosphonic Acids Form High-Quality Self-Assembled Monolayers on Ag-Coated Yttrium Barium Copper Oxide Tapes and Enable Filamentization of the Tapes by Microcontact Printing.

    PubMed

    Park, Chul Soon; Lee, Han Ju; Lee, Dahye; Jamison, Andrew C; Galstyan, Eduard; Zagozdzon-Wosik, Wanda; Freyhardt, Herbert C; Jacobson, Allan J; Lee, T Randall

    2016-08-30

    A custom-designed semifluorinated phosphonic acid, (9,9,10,10,11,11,12,12,13,13,14,14,15,15,16,16,16-heptadecafluorohexadecyl)phosphonic acid (F8H8PA), and a normal hexadecylphosphonic acid (H16PA) were synthesized and used to generate self-assembled monolayers (SAMs) on commercially available yttrium barium copper oxide (YBCO) tapes. In this study, we wished to evaluate the effectiveness of these monolayer films as coatings for selectively etching YBCO. Initial films formed by solution deposition and manual stamping using a non-patterned polydimethylsiloxane stamp allowed for a comparison of the film-formation characteristics. The resulting monolayers were characterized by X-ray photoelectron spectroscopy (XPS), contact angle goniometry, and polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS). To prepare line-patterned (filamentized) YBCO tapes, standard microcontact printing (μ-CP) procedures were used. The stamped patterns on the YBCO tapes were characterized by scanning electron microscopy (SEM) before and after etching to confirm the effectiveness of the patterning process on the YBCO surface and energy-dispersive X-ray spectroscopy (EDX) to obtain the atomic composition of the exposed interface.

  18. Removal of an eroded transobturator tape from the bladder using laser cystolithotripsy and cystoscopic resection.

    PubMed

    Feiner, Benny; Auslender, Ron; Mecz, Yoel; Lissak, Arie; Stein, Avi; Abramov, Yoram

    2009-03-01

    This case presentation describes a unique minimally invasive technique of treating transobturator tape erosion into the urinary bladder with calculus growth. A 42-year-old woman was admitted for recurrent urinary tract infections, 9 months after a transobturator tape procedure. Pelvic sonography, followed by cystourethroscopy, demonstrated an eroded tape in the bladder with heavy calculus growth and diffuse mucosal inflammation. The calculus was fragmented by using laser cystolithotripsy, and the tape was excised and removed by using cystoscopic resection. Intravesical tape erosion with calculus growth can complicate transobturator tape procedures, and is amenable to transurethral laser cystolithotripsy and cystoscopic resection.

  19. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  20. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha [Los Alamos, NM; Matias, Vladimir [Santa Fe, NM; Arendt, Paul N [Los Alamos, NM; Foltyn, Stephen R [Los Alamos, NM; Bronisz, Lawrence E [Los Alamos, NM

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  1. Experimental Investigations of Woven Textile Tape as Strain Sensor

    NASA Astrophysics Data System (ADS)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  2. AC loss measurements of twisted and untwisted BSCCO multifilamentary tapes

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Nishioka, Takamasa; Oh, Sang-Soo

    2005-01-01

    AC losses in twisted and untwisted BSCCO multifilamentary superconducting tapes with Ag matrix developed in DAPAS program were measured by an electrical method. Magnetization and transport losses were measured by a pick-up coil and by a voltage taps. Total AC loss during simultaneous application of AC transport current and an AC transverse magnetic field was given by the sum of the magnetization and transport losses measured during this simultaneous application. The magnetization loss without transport current of untwisted and twisted tapes was measured first to evaluate the effect of twisting to decouple filaments. Then, the total AC loss of the twisted tape was measured in transverse magnetic fields with various amplitudes and orientations, while the amplitude of the transport current was fixed. The measured total AC loss in a parallel transverse magnetic field was compared with some theoretical models to study the detailed characteristics of the measured total AC loss of the sample.

  3. Critical Current Measurements in Commercial Tapes, Coils, and Magnets.

    NASA Astrophysics Data System (ADS)

    Gubser, D. U.; Soulen, R. J., Jr.; Fuller-Mora, W. W.; Francavilla, T. L.

    1996-03-01

    We have measured a number of tapes, coils, and magnets produced by commercial vendors and determined their properties as functions of magnetic field and temperature. The tapes were measured at the National High Magnetic Field Laboratory in magnetic fields to 20 tesla and at temperatures of 4.2 K, 27 K, 65 K, and 77 K. For the tapes we report critical currents and current-voltage characteristics. Six inch diameter coils were measured at NRL in zero magnetic field. Critical currents, current-voltage characteristics, and reliability studies are reported for the coils. Larger 10 inch diameter coils, which are to be used in a 200 hp superconducting motor, were also measured and results will be presented. The talk will also review the status of the most recent tests of the superconducting motor.

  4. Mirror-touch and ticker tape experiences in synesthesia.

    PubMed

    Chun, Charlotte A; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2-4%) and sequence-space synesthesia (9-14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes.

  5. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  6. Gauze and tape and transparent polyurethane dressings for central venous catheters.

    PubMed

    Webster, Joan; Gillies, Donna; O'Riordan, Elizabeth; Sherriff, Karen L; Rickard, Claire M

    2011-11-09

    Central venous catheters (CVCs) facilitate venous access, allowing the intravenous administration of complex drug treatments, blood products and nutritional support, without the trauma associated with repeated venepuncture. However, CVCs are associated with a risk of infection. Some studies have indicated that the type of dressing used with them may affect the risk of infection. Gauze and tape, transparent polyurethane film dressings such as Tegaderm® and Opsite®, and highly vapour-permeable transparent polyurethane film dressings such as Opsite IV3000®, are the most common types of dressing used to secure CVCs. Currently, it is not clear which type of dressing is the most appropriate. To compare gauze and tape with transparent polyurethane CVC dressings in terms of catheter-related infection, catheter security, tolerance to dressing material and dressing condition in hospitalised adults and children. For this third update, we searched The Cochrane Wounds Group Specialised Register (10 May 2011); The Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library 2011, Issue 2), Ovid MEDLINE (1950 to April Week 4 2011); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, May 11, 2011); Ovid EMBASE (1980 to 2011 Week 18); and EBSCO CINAHL (1982 to 6 May 2011). All randomised controlled trials (RCTs) evaluating the effects of dressing type (e.g. gauze and tape versus transparent polyurethane dressings) on CVC-related infection, catheter security, tolerance to dressing material and dressing condition in hospitalised patients. Two review authors independently assessed trial quality and extracted data. We contacted study authors for missing information. Six studies were included in earlier versions of the review. In this update two of the previously included papers have been excluded and two new trials have been added. Of these six trials, four compared gauze and tape with transparent polyurethane dressings (total participants = 337) and two

  7. How to advise a woman who wants to get pregnant after a sub-urethral tape placement?

    PubMed

    Panel, Laure; Triopon, Grégory; Courtieu, Christophe; Marès, Pierre; de Tayrac, Renaud

    2008-03-01

    Our objective was to make recommendations for the follow-up of pregnancies and the choice of delivery route for patients becoming pregnant after surgical treatment of stress urinary incontinence (SUI) by tension-free vaginal tape (TVT) or trans-obturator tape (TOT). We performed a retrospective survey on pregnancies after surgical treatment of SUI. Nineteen physicians out of 3,400 contacted reported a total of 20 pregnancies after TVT or TOT. Three patients had recurrent SUI during pregnancy. No major complications of the tape occurred during pregnancy. Ten patients out of 20 delivered vaginally, and nine had a caesarean section. Mean follow-up after delivery was 13.8 months (1 to 52). Recurrence of SUI was observed in 3 of 20 (15%) during pregnancy and in 3 of 18 (16.7%) after delivery. The global rate of recurrence was 4 of 18 (22.2%). Recurrence of SUI was two of ten cases after vaginal delivery (20%) and in one of eight after caesarean section (12.5%; p=0.58). Vaginal delivery did not increase the risk of recurrence.

  8. Leprosy wound healing with ordinary adhesive tape. A preliminary report.

    PubMed

    Stenström, S; Hallmans, G; De Jongh, A; De Wael, T

    1976-01-01

    The use of adhesive tape as wound treatment in leprosy cases is described and found to be superior to the classical dressing as regards security and facility of application, and for the rapidity and quality of healing. Its use as a "preventive" treatment is stressed. The results of this study seem to justify the following conclusions: The adhesive tape is easy to handle, it heals the leprosy wounds in about half the time necessary for the classical dressing and it costs about 50 times less.

  9. Astronaut Rich Clifford inserts tape into payload high data recorder

    NASA Image and Video Library

    1994-04-14

    STS059-09-012 (9-20 April 1994) --- On the Space Shuttle Endeavour's aft flight deck, astronaut Michael R. (Rich) Clifford, mission specialist, inserts a tape in the payload high rate recorder. Three of these state-of-the-art recorders captured four times the amount of data that could be radioed to the ground. The 183 tapes, each containing 40 megabytes of data, will be turned into images over the next year, and analyzed over the next decade. Clifford was joined in space by five other NASA astronauts for a week and a half of support to the Space Radar Laboratory (SRL-1)/STS-59 mission.

  10. STS-97 Mission Highlights Resource Tape. Part 2

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A continuation of 'STS-97 Mission Highlights Resource Tape, Part 1 of 3' (document ID 20010020281), the activities of flight days four through six are seen. Footage includes the spacewalks performed by Noriega and Tanner, the deployment of the Solar Array Blanket Box (SABB), various shots of Endeavour's payload bay and the International Space Station (ISS), and the deployment of the solar radiators on the ISS. Flight days seven through eleven and Endeavour's landing are shown in 'STS-97 Mission Highlights Resource Tape, Part 3 of 3' (document ID 20010020283).

  11. Use of the Broselow tape in a Mexican emergency department.

    PubMed

    Khouli, Michael; Ortiz, Mario I; Romo-Hernández, Georgina; Martínez-Licona, Domitila; Stelzner, Sarah M

    2015-06-01

    The Broselow tape is one method for rapid weight estimation in pediatric patients undergoing resuscitation, but it does not perform equally in all populations. To date, we are unaware of any study evaluating its use in a Latin American population. To investigate the accuracy of the Broselow tape in a Mexican emergency department (ED). We conducted a prospective, observational study of children presenting to a Mexican ED. Patient weight was estimated using the Broselow tape and the estimate compared to their weight measured on a scale. Researchers were blinded to scale weight and Broselow categories. For analysis, the Broselow tape's nine color zones were divided into three weight categories. Of 815 subjects, 356 (43.7%) were female. In children weighing <10 kg, the tape tended to underestimate weight, whereas it overestimated weight in the other two weight categories. The mean percentage difference between the actual weight and the Broselow tape-predicted weight was <3% in each category, although it differed significantly across the three weight categories. Accuracy of the predicted weight to within 10% of actual weight was lowest for children weighing <10 kg, at 46.2% (confidence interval [CI] ± 6.4%), and greatest for those in the 10-18-kg weight category, at 64.1% (CI ± 5.1%). However, the correlation of color zones predicted by both methods was highest for subjects <10 kg at 64.4% (CI ± 6.1%). It was significantly lower in the other weight categories at 54.5% (CI ± 5.3) for subjects weighing 10-18 kg, and 50.1% (CI ± 6.4%) for subjects weighing >18 kg. The percentage of children for whom the color code differed by two or more categories was <4% overall and for each weight category. The Broselow tape-estimated weight was different from the scale weight by more than 10% in a substantial percentage of Mexican children. Nevertheless, the mean percentage difference was <3%, and Broselow tape color zone estimation was accurate in the majority of subjects

  12. Improvement in performance of heat exchanger fitted with twisted tape

    SciTech Connect

    Sivashanmugam, P.; Sundaram, S.

    1999-04-01

    The improvement in performance of a double pipe heat exchanger fitted with twisted tape as a turbulence promoter with twist ratios of 15.649, 8.54, 5.882, 4.95, and 4.149 was experimentally studied. A maximum percentage gain of 44.7% in energy transfer rate was obtained for the twisted tape of twist ratio 4.149. For all twist ratios, the gain decreases with the Reynolds number and becomes constant for Reynolds numbers greater than 3,000. The smaller the twist ratio is, the larger the gain in energy for a specific Reynolds number.

  13. TM digital image products for applications. [computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Barker, J. L.; Gunther, F. J.; Abrams, R. B.; Ball, D.

    1984-01-01

    Computer compatible tapes (CCTs) of LANDSAT 4 thematic mapper (TM) digital image products are compared and reviewed. The following tape formats are discussed: (1) raw band-sequential data (CCT-BT); (2) calibrated data (CCT-AT); and (3) geometrically resampled data (CCT-PT). Each format represents different steps in the process of producing fully corrected TM data. The CCT-BT images are uncorrected radiometrically or geometrically, CCT-AT data are radiometrically calibrated, and CCT-PT images are both radiometrically and geometrically corrected.

  14. The new CERN tape software - getting ready for total performance

    NASA Astrophysics Data System (ADS)

    Cano, E.; Murray, S.; Kruse, D. F.; Kotlyar, V.; Côme, D.

    2015-12-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  15. Overview of Challenger Space Shuttle tape-data recovery study

    NASA Astrophysics Data System (ADS)

    Bhushan, B.; Phelan, R. M.

    1987-09-01

    The Challenger Orbiter's magnetic flight recorder tapes underwent six weeks of deterioration in sea water, and could not be unwound without damage to the recording surface. Attention is presently given to the method used to chemically treat the damaged magnesium tape reels in a wash tank, under partial vacuum, with nitric acid and methanol. The treated reel was relubricated before careful unwinding at 0.15 m/min. Over 90 percent of the data blocks from a recorder were readable, and 100 percent of the voice data blocks were recovered.

  16. Efficacy of knee tape in the management of osteoarthritis of the knee: blinded randomised controlled trial.

    PubMed

    Hinman, Rana S; Crossley, Kay M; McConnell, Jenny; Bennell, Kim L

    2003-07-19

    To test the hypotheses that therapeutic taping of the knee improves pain and disability in patients with osteoarthritis of the knee and that benefits remain after stopping treatment. Randomised single blind controlled trial with three intervention arms (therapeutic tape, control tape, and no tape) of three weeks' duration and three week follow up. Outcome assessment was performed in a university based laboratory. Taping interventions were applied by eight physiotherapists in metropolitan private practice. 87 patients with symptoms of knee osteoarthritis as defined by the American College of Rheumatology. Primary outcome measure was pain as measured by visual analogue scale and participant perceived rating of change. Secondary measures of pain and disability included the Western Ontario and MacMaster Universities osteoarthritis index, knee pain scale, and the SF-36. The therapeutic tape group reported a greater reduction in pain on all primary outcomes than either of the other two groups. A significant association was evident between intervention and change in pain at three weeks (P=0.000), with 73% (21/29) of the therapeutic tape group reporting improvement compared with 49% (14/29) of the control tape group and 10% (3/29) of the no tape group. Significantly greater improvement in pain and disability was observed on most secondary outcomes in the therapeutic tape group compared with the no tape group. Benefits of therapeutic tape were maintained three weeks after stopping treatment. Therapeutic knee taping is an efficacious treatment for the management of pain and disability in patients with knee osteoarthritis.

  17. The effect of balance taping for prevention of menstrual pain in female middle school students.

    PubMed

    Yum, Keun-Sang; Kang, Sung-Goo; Han, Hyun-Jin

    2017-05-01

    [Purpose] The age at menarche in Korean women has been declining sharply. However, for the students who are just beginning to menstruate, taking pain medication might become a long-term habit continuing until adulthood. Therefore, this study investigated whether balance taping would be more helpful than medication in relieving the pain. [Subjects and Methods] Subjects of this study included 125 female students. The participants were assigned to the balance taping group, the control group, and the medication group. The medication group was given 1 dose of Tylenol (acetaminophen 500 mg) and the balance-taping group had taping applied, and the changes in pain were measured before the taping, as well as1 hour, 4 hours, 8 hours, and 24 hours after. The measurement was done two times for the repeatability of the result. [Results] The balance-taping group showed a difference in pain from 1 hour after the taping compared with the control group, and the pain was significantly reduced until 24 hours after the taping. The balance taping group showed a statistically significant difference in pain compared with the medication group from 4 hours after the taping, and it lasted until 24 hours after the taping. The results were similar in the second measurement as well. [Conclusion] Balance taping was shown to be effective in relieving menstrual pain. Balance taping could be an effective alternative to medication in relieving menstrual pain and distress.

  18. Programmable flow-based dynamic sorptive microextraction exploiting an octadecyl chemically modified rotating disk extraction system for the determination of acidic drugs in urine.

    PubMed

    Manzo, Valentina; Miró, Manuel; Richter, Pablo

    2014-11-14

    A novel automatic sorptive microextraction approach combining sequential injection-based programmable flow with rotating disk sorptive extraction (RDSE) is proposed for the clean-up and concentration of low polarity organic species in urine samples. Non-steroidal anti-inflammatory drugs (NSAIDs), namely, ketoprofen, naproxen, diclofenac and ibuprofen, were selected as model analytes in a proof-of-concept design, and they were further determined by liquid chromatographic (LC) assays. The extracting phase consisted of octadecyl (C18) chemically bonded silica embedded in a polytetrafluoroethylene (PTFE) substrate. The thin film was immobilized onto the surface of an in-house prepared rotating PTFE disk in a dedicated flow-through chamber. The programmable flow-based microextraction method operates under kinetic principles and features software-controlled sample loading and dynamic sorptive unidirectional-flow microextraction for as little as 10 min, followed by matrix clean-up and in-line elution with methanol. The hydrophobic thin-film extracting phase was demonstrated to be reusable for at least 15 consecutive extractions in urine without removing or changing the disk. The relative recoveries of the NSAIDs in urine ranged from 101 to 106% using a matrix-matched calibration curve, with extraction efficiencies of 30-38% using a dynamic regime, an enrichment factor of approximately 17 for 10 mL sample and relative standard deviations (RSD) between 3 and 6%. The detection limits (3 × S/N ratio) of the in-line sample preparation method coupled to LC-UV detection ranged from 0.022 to 0.044 mg L(-1). Using NSAID monitored in urine from individuals who received oral administration of ibuprofen and diclofenac, the automatic sample handling method was proven to be efficient for urine clean-up and the determination of acidic drugs at biologically relevant levels.

  19. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography-mass spectrometry.

    PubMed

    Alcudia-León, M Carmen; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel; Kabir, Abuzar; Furton, Kenneth G

    2017-03-10

    This article presents a novel unit that integrates for the first time air sampling and preconcentration based on the use of fabric phase sorptive extraction principles. The determination of Tuta absoluta sexual pheromone traces in environmental air has been selected as analytical problem. For this aim, a novel laboratory-built unit made up of commercial brass elements as holder of the sol-gel coated fabric extracting phase has been designed and optimized. The performance of the integrated unit was evaluated analyzing environmental air sampled in tomato crops. The unit can work under sampling and analysis mode which eliminates any need for sorptive phase manipulation prior to instrumental analysis. In the sampling mode, the unit can be connected to a sampling pump to pass the air through the sorptive phase at a controlled flow-rate. In the analysis mode, it is placed in the gas chromatograph autosampler without any instrumental modification. It also diminishes the risk of cross contamination between sampling and analysis. The performance of the new unit has been evaluated using the main components of the sexual pheromone of Tuta absoluta [(3E,8Z,11Z)-tetradecatrien-1-yl acetate and (3E,8Z)-tetradecadien-1-yl acetate] as model analytes. The limits of detection for both compounds resulted to be 1.6μg and 0.8μg, respectively, while the precision (expressed as relative standard deviation) was better than 3.7%. Finally, the unit has been deployed in the field to analyze a number of real life samples, some of them were found positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Sorptive thin film microextraction followed by direct solid state spectrofluorimetry: A simple, rapid and sensitive method for determination of carvedilol in human plasma.

    PubMed

    Karimi, Shima; Talebpour, Zahra; Adib, Noushin

    2016-06-14

    A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma.