Sample records for container leakage testing

  1. 49 CFR 173.306 - Limited quantities of compressed gases.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., in addition, one container in 2,000 must be tested at the higher temperature. No leakage or permanent... °F) but, in addition, one container in 2,000 must be tested at the higher temperature. No leakage or... the design pressure of the container. If any container shows evidence of leakage at a rate equal to or...

  2. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Pressure and leakage tests. 178.345-13 Section 178... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a) Each cargo tank must be pressure and leakage tested in accordance with this section and...

  3. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... entire cargo tank surface is inspected for leakage and other sign of defects. The inspection method must... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a) Each cargo tank must be pressure and leakage tested in accordance with this section and §§ 178.346-5, 178.347...

  4. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... entire cargo tank surface is inspected for leakage and other sign of defects. The inspection method must... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a) Each cargo tank must be pressure and leakage tested in accordance with this section and §§ 178.346-5, 178.347...

  5. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... entire cargo tank surface is inspected for leakage and other sign of defects. The inspection method must... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a) Each cargo tank must be pressure and leakage tested in accordance with this section and §§ 178.346-5, 178.347...

  6. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... entire cargo tank surface is inspected for leakage and other sign of defects. The inspection method must... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a) Each cargo tank must be pressure and leakage tested in accordance with this section and §§ 178.346-5, 178.347...

  7. An analysis of blood specimen container leakage.

    PubMed Central

    Lewis, S M; Wardle, J M

    1978-01-01

    Procedures have been designed to test specimen containers for leakage, using blood and aqueous fluorescein solution as indicators. They have been used in a trial evaluation of a number of commercially available containers intended for medical specimens. Glass bijou bottles, evacuated container systems, and several types of plastic container showed no significant leakage rate with either blood or aqueous solution when they were tested at room temperature, but a large proportion of the plastic containers leaked after being subjected to -20 degrees. C. These would thus be suitable and satisfactory for blood count specimens but not for specimens of serum and other body fluids, which are usually stored frozen. With all types of container tested there was spontaneous discharge of contents (blood or aqueous solution) on opening in a proportion of them; thus no container at present available seems to be entirely free from hazard. PMID:711921

  8. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test..., and the inspection pressure is tank MAWP. [Amdt. 178-89, 54 FR 25032, June 12, 1989. Redesignated by...

  9. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test..., and the inspection pressure is tank MAWP. [Amdt. 178-89, 54 FR 25032, June 12, 1989. Redesignated by...

  10. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test..., and the inspection pressure is tank MAWP. [Amdt. 178-89, 54 FR 25032, June 12, 1989. Redesignated by...

  11. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test..., and the inspection pressure is tank MAWP. [Amdt. 178-89, 54 FR 25032, June 12, 1989. Redesignated by...

  12. 10 CFR Appendix J to Part 50 - Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... air test pressure and to assure they will be subjected to the post accident differential pressure... Table of Contents I. Introduction. II. Explanation of terms. III. Leakage test requirements. A. Type A test. B. Type B test. C. Type C test. D. Periodic retest schedule. IV. Special test requirements. A...

  13. 10 CFR Appendix J to Part 50 - Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... air test pressure and to assure they will be subjected to the post accident differential pressure... Table of Contents I. Introduction. II. Explanation of terms. III. Leakage test requirements. A. Type A test. B. Type B test. C. Type C test. D. Periodic retest schedule. IV. Special test requirements. A...

  14. 10 CFR Appendix J to Part 50 - Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... air test pressure and to assure they will be subjected to the post accident differential pressure... Table of Contents I. Introduction. II. Explanation of terms. III. Leakage test requirements. A. Type A test. B. Type B test. C. Type C test. D. Periodic retest schedule. IV. Special test requirements. A...

  15. 10 CFR Appendix J to Part 50 - Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... air test pressure and to assure they will be subjected to the post accident differential pressure... Table of Contents I. Introduction. II. Explanation of terms. III. Leakage test requirements. A. Type A test. B. Type B test. C. Type C test. D. Periodic retest schedule. IV. Special test requirements. A...

  16. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure..., the test pressure must be 40 psig or 1.5 times tank MAWP, whichever is greater, and the inspection...

  17. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must be the greater of 5.0 psig or 1.5 times the cargo tank MAWP, and the inspection pressure must be... Specifications for Containers for Motor Vehicle Transportation § 178.346-5 Pressure and leakage tests. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test...

  18. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test... pressure must be 40 psig or 1.5 times tank MAWP, whichever is greater, and the inspection pressure is tank...

  19. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test... pressure must be 40 psig or 1.5 times tank MAWP, whichever is greater, and the inspection pressure is tank...

  20. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test... pressure must be 40 psig or 1.5 times tank MAWP, whichever is greater, and the inspection pressure is tank...

  1. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... must be the greater of 5.0 psig or 1.5 times the cargo tank MAWP, and the inspection pressure must be... Specifications for Containers for Motor Vehicle Transportation § 178.346-5 Pressure and leakage tests. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test...

  2. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... must be the greater of 5.0 psig or 1.5 times the cargo tank MAWP, and the inspection pressure must be... Specifications for Containers for Motor Vehicle Transportation § 178.346-5 Pressure and leakage tests. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test...

  3. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test... pressure must be 40 psig or 1.5 times tank MAWP, whichever is greater, and the inspection pressure is tank...

  4. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... must be the greater of 5.0 psig or 1.5 times the cargo tank MAWP, and the inspection pressure must be... Specifications for Containers for Motor Vehicle Transportation § 178.346-5 Pressure and leakage tests. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test. Test...

  5. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... test pressure must be the greater of 5.0 psig or 1.5 times the cargo tank MAWP, and the inspection... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.346-5 Pressure and leakage tests. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure...

  6. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure....5 times tank MAWP, and the inspection pressure is tank MAWP. [Amdt. 178-89, 54 FR 25032, June 12...

  7. EVALUATION OF LEAKAGE FROM FUME HOODS USING TRACER GAS, TRACER NANOPARTICLES AND NANOPOWDER HANDLING TEST METHODOLOGIES

    PubMed Central

    Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.

    2015-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285

  8. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    PubMed

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.

  9. An Investigation of Tendon Corrosion-Inhibitor Leakage into Concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costello, J.F.; Naus, D.J.; Oland, C.B.

    1999-07-05

    During inspections performed at US nuclear power plants several years ago, some of the prestressed concrete containment had experienced leakage of the tendon sheathing filler. A study was conducted to indicate the extent of the leakage into the concrete and its potential effects on concrete properties. Concrete core samples were obtained from the Trojan Nuclear Plant. Examination and testing of the core samples indicated that the appearance of tendon sheathing filler on the surface was due to leakage of the filler from the conduits and its subsequent migration to the concrete surface through cracks that were present. Migration of themore » tendon sheathing filler was confined to the cracks with no perceptible movement into the concrete. Results of compressive strength tests indicated that the concrete quality was consistent in the containment and that the strength had increased relative to the strength at 28 days age.« less

  10. Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Wanyu R.; Joh, Jeffrey; Sherman, Max H.

    2012-08-01

    LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximatelymore » 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.« less

  11. 10 CFR Appendix J to Part 50 - Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Containment inspection. B. Repordkeeping of test results. I. Introduction One of the conditions of all... following: A. Type A test—1. Pretest requirements. (a) Containment inspection in accordance with V. A. shall.... During the period between the completion of one Type A test and the initiation of the containment...

  12. Application of the Booth-Kautzmann method for the determination of N-2 packing leakage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burkhart, D.M.; Milton, J.W.; Fawcett, S.T.

    1995-06-01

    To accurately determine turbine cycle heat rate, leakage past the N-2 steam seal packing must be determined on turbines with both HP and IP turbines contained within a common high pressure casing. N-2 packing leakage can be determined by the Booth-Kautzmann Method with instrumentation commonly used to determine the HP and IP turbine efficiency. The only additional requirements are changes to the main steam and/or hot reheat steam conditions. This paper discusses the actual test results using the Booth-Kautzmann test procedure on three natural gas fired units. The test results demonstrate the added advantage of having at least three N-2more » test runs, stability requirements for repeatable test runs and test procedures used to determine leakage results. Discussion of the sensitivity of the assumed N-2 enthalpy are also addressed. Utilizing Martins Formula with a series of N-2 Leakage test runs is shown to be a leakage prediction tool and a packing clearance approximation tool. It is concluded that the Booth-Kautzmann Method for determination of N-2 packing leakage should be utilized whenever HP and Ip turbine efficiency is determined. The two or three additional hours invested in the test runs is well worth the information gained on the performance of the N-2 packing.« less

  13. 78 FR 53482 - Entergy Operations, Inc., River Bend Station, Unit 1; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-29

    ... facility consists of a boiling-water reactor located in West Feliciana Parish, Louisiana. 2.0 Request... Containment Leakage Testing for Water- Cooled Power Reactors,'' requires that components which penetrate containment be periodically leak tested at the ``P a, '' defined as the ``calculated peak containment internal...

  14. Inspection tool for butt-welded tubing

    NASA Technical Reports Server (NTRS)

    Horman, D. P.

    1977-01-01

    Inspection tool for tubing consists of metal casing housing elastic collar. Collar is clamped around weld site under test. Leakage through weld is contained within chamber and is bled to detector via tubing attached to fitting. Tool, originally designed to detect fluid leakage in tubing, can be used to detect gas leaks.

  15. Containment penetration elastomer seal leak rate tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bridges, T.L.

    1987-07-01

    Tests were performed on three elastomer seal designs commonly used for nuclear plant containment mechanical penetrations. The objective of this research project is to obtain an understanding of the integrity and leakage behavior of these seal designs under severe accident temperature and pressure conditions. The three designs tested and the seal materials used in the tests were: (1) double tongue-and-groove design with silicone rubber seals, (2) double-O-ring design with neoprene and ethylene-propylene (EPDM) seals, and (3) double gumdrop design with neoprene and EPDM seals. The effects of thermal aging and angular rotations of flange mating surfaces were determined. The testmore » results provide information required to characterize the leakage behavior of penetrations under severe accident conditions. 3 refs., 10 figs., 12 tabs.« less

  16. Fuel subassembly leak test chamber for a nuclear reactor

    DOEpatents

    Divona, Charles J.

    1978-04-04

    A container with a valve at one end is inserted into a nuclear reactor coolant pool. Once in the pool, the valve is opened by a mechanical linkage. An individual fuel subassembly is lifted into the container by a gripper; the valve is then closed providing an isolated chamber for the subassembly. A vacuum is drawn on the chamber to encourage gaseous fission product leakage through any defects in the cladding of the fuel rods comprising the subassembly; this leakage may be detected by instrumentation, and the need for replacement of the assembly ascertained.

  17. Investigation of the Leak Response of a Carbon-Fiber Laminate Loaded in Biaxial Tension

    NASA Technical Reports Server (NTRS)

    Jackson, Wade C.; Ratcliffe, James G.

    2013-01-01

    Designers of pressurized structures have been reluctant to use composite materials because of concerns over leakage. Biaxial stress states are expected to be the worst-case loading condition for allowing leakage to occur through microcracks. To investigate the leakage behavior under in-plane biaxial loading, a cruciform composite specimen was designed that would have a relatively large test section with a uniform 1:1 biaxial loading ratio. A 7.6-cm-square test section was desired for future investigations of the leakage response as a result of impact damage. Many iterations of the cruciform specimen were evaluated using finite element analysis to reduce stress concentrations and maximize the size of the uniform biaxial strain field. The final design allowed the specimen to go to relatively high biaxial strain levels without incurring damage away from the test section. The specimen was designed and manufactured using carbon/epoxy fabric with a four-ply-thick, quasi-isotropic, central test section. Initial validation and testing were performed on a specimen without impact damage. The specimen was tested to maximum biaxial strains of approximately 4500micro epsilon without apparent damage. A leak measurement system containing a pressurized cavity was clamped to the test section and used to measure the flow rate through the specimen. The leakage behavior of the specimen was investigated for pressure differences up to 172 kPa

  18. Color film preservation system: Breadboard development

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The development of an economically feasible system to prevent and/or substantially reduce the degradation of the color dyes of the retinal reflex images recorded on color slide films is discussed. Three different types of film storage systems were designed, fabricated, and tested. An extruded plastic cylindrical container was pressurized and no observable leakage occurred, indicating that long term storage is possible. An operational breadboard was fabricated. The system offers the capability to determine purging requirements to achieve various levels of oxygen concentration and precise leakage of various container configurations. The system has digitial display of oxygen content of the container, automatic control of the oxygen content as well as of the container to atmosphere pressure differential, and flow rate readout during purging.

  19. Flow Characteristics and Robustness of an Inclined Quad-vortex Range Hood

    PubMed Central

    CHEN, Jia-Kun; HUANG, Rong Fung

    2014-01-01

    A novel design of range hood, which was termed the inclined quad-vortex (IQV) range hood, was examined for its flow and containment leakage characteristics under the influence of a plate sweeping across the hood face. A flow visualization technique was used to unveil the flow behavior. Three characteristic flow modes were observed: convex, straight, and concave modes. A tracer gas detection method using sulfur hexafluoride (SF6) was employed to measure the containment leakage levels. The results were compared with the test data reported previously in the literature for a conventional range hood and an inclined air curtain (IAC) range hood. The leakage SF6 concentration of the IQV range hood under the influence of the plate sweeping was 0.039 ppm at a suction flow rate of 9.4 m3/min. The leakage concentration of the conventional range hood was 0.768 ppm at a suction flow rate of 15.0 m3/min. For the IAC range hood, the leakage concentration was 0.326 ppm at a suction flow rate of 10.9 m3/min. The IQV range hood presented a significantly lower leakage level at a smaller suction flow rate than the conventional and IAC range hoods due to its aerodynamic design for flow behavior. PMID:24583513

  20. CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.

    PubMed

    Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki

    2010-08-01

    By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.

  1. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, T. M.; Wilke, R. J.; Roberts, T.

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration systemmore » in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building. The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference. Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five isomers of the PFT PDCH (mtPDCH, pcPDCH, otPDCH, mcPDCH, and ptPDCH). These isomers were quantified in the low concentration samples in the Alpha test and in all samples in the Bravo test. The best estimates of UI (Rui) for the four zones are provided in Table ES-1. For the CB, this estimate averages the four tracers at the four elevations. For the CR, this estimate uses the four sampling units located in the Control Room.« less

  2. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, T. M.; Wilke, R. J.; Roberts, T.

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration systemmore » in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building.The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference.Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five isomers of the PFT PDCH (mtPDCH, pcPDCH, otPDCH, mcPDCH, and ptPDCH). These isomers were quantified in the low concentration samples in the Alpha test and in all samples in the Bravo test.The best estimates of UI (Rui) for the four zones are provided in Table ES-1. For the CB, this estimate averages the four tracers at the four elevations. For the CR, this estimate uses the four sampling units located in the Control Room.« less

  3. LEAKAGE TESTING METHOD

    DOEpatents

    McAdams, Wm.A.; Foss, M.H.

    1958-08-12

    A method of testing containers for leaks is described, particularly the testing of containers or cans in which the uranium slugs for nuelear reactors are jacketed. This method involves the immersion of the can in water under l50 pounds of pressure, then removing, drying, and coating the can with anhydrous copper sulfate. Amy water absorbed by the can under pressure will exude and discolor the copper sulfate in the area about the leak.

  4. Composite Crew Module (CCM) Permeability Characterization

    NASA Technical Reports Server (NTRS)

    Kirsch, Michael T.

    2013-01-01

    In January 2007, the NASA Administrator chartered the NASA Engineering and Safety Center (NESC) to form an Agency team to design and build a composite crew module in 18 months in order to gain hands-on experience in anticipation that future exploration systems may be made of composite materials. One of the conclusions from this Composite Crew Module Primary Structure assessment was that there was a lack of understanding regarding the ability for composite pressure shells to contain consumable gases, which posed a technical risk relative to the use of a metallic design. After the completion of the Composite Crew Module test program, the test article was used in a new program to assess the overall leakage/permeability and identify specific features associated with high leak rates. This document contains the outcome of the leakage assessment.

  5. Development of braided fiber seals for engine applications

    NASA Technical Reports Server (NTRS)

    Cai, Zhong; Mutharasan, Rajakkannu; Ko, Frank K.; Du, Guang-Wu; Steinetz, Bruce M.

    1993-01-01

    A new type of braided fiber seal was developed for high temperature engine applications. Development work performed includes seal design, fabrication, leakage flow testing, and flow resistance modeling. This new type of seal utilizes the high flow resistance of tightly packed fibers and the conformability of textile structures. The seal contains a core part with aligned fibers, and a sheath with braided fiber layers. Seal samples are made by using the conventional braiding process. Leakage flow measurements are then performed. Mass flow rate versus the simulated engine pressure and preload pressure is recorded. The flow resistance of the seal is analyzed using the Ergun equation for flow through porous media, including both laminar and turbulent effects. The two constants in the Ergun equation are evaluated for the seal structures. Leakage flow of the seal under the test condition is found to be in the transition flow region. The analysis is used to predict the leakage flow performance of the seal with the determined design parameters.

  6. Aerodynamics and performance verifications of test methods for laboratory fume cupboards.

    PubMed

    Tseng, Li-Ching; Huang, Rong Fung; Chen, Chih-Chieh; Chang, Cheng-Ping

    2007-03-01

    The laser-light-sheet-assisted smoke flow visualization technique is performed on a full-size, transparent, commercial grade chemical fume cupboard to diagnose the flow characteristics and to verify the validity of several current containment test methods. The visualized flow patterns identify the recirculation areas that would inevitably exist in the conventional fume cupboards because of the fundamental configurations and structures. The large-scale vortex structures exist around the side walls, the doorsill of the cupboard and in the vicinity of the near-wake region of the manikin. The identified recirculation areas are taken as the 'dangerous' regions where the risk of turbulent dispersion of contaminants may be high. Several existing tracer gas containment test methods (BS 7258:1994, prEN 14175-3:2003 and ANSI/ASHRAE 110:1995) are conducted to verify the effectiveness of these methods in detecting the contaminant leakage. By comparing the results of the flow visualization and the tracer gas tests, it is found that the local recirculation regions are more prone to contaminant leakage because of the complex interaction between the shear layers and the smoke movement through the mechanism of turbulent dispersion. From the point of view of aerodynamics, the present study verifies that the methodology of the prEN 14175-3:2003 protocol can produce more reliable and consistent results because it is based on the region-by-region measurement and encompasses the most area of the entire recirculation zone of the cupboard. A modified test method combined with the region-by-region approach at the presence of the manikin shows substantially different results of the containment. A better performance test method which can describe an operator's exposure and the correlation between flow characteristics and the contaminant leakage properties is therefore suggested.

  7. Drop Testing Representative Multi-Canister Overpacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, Spencer D.; Morton, Dana K.

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capablemore » of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10 -5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10 -7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.« less

  8. A Study to Analyze the Permeation of High Density Gases and Propellant Vapors Through Single Layer Teflon or Teflon Structure Materials and Laminations. Volume 1

    NASA Technical Reports Server (NTRS)

    Johnson, R. L.; Young, Donald L. (Technical Monitor)

    1967-01-01

    This report contains the results of a fifteen month analytical and experimental study of the leakage rate of the pressurant gases (N2, He) and the propellant vapors (N2O4,N2H4) through bladder structures consisting of two layers of Teflon separated by a metallic foil diffusion barrier containing microscopic or larger holes. Results were obtained for the steady state leakage rate through circular holes and long rectangular openings in the barrier for arbitrary thicknesses of the two Teflon layers. The effect of hole shape and relative hole position on the leakage rate were studied. The transient problem was analyzed and it was shown that steady state calculations are adequate for estimating the leakage rate. A computer program entitled "Diffusion Analyzer Program" was developed to calculate the leakage rate, both transient and steady state. Finally, the analytical results were compared to experimentally determined values of the leakage rate through a model laminated bladder structure. The results of the analysis are in good agreement with experiment. The experimental effort (Part II of the Bladder Permeation Program) measured the solubility, diffusion coefficient and permeability of helium, nitrogen and nitrogen tetroxide vapor through Teflon TFE and FEP membranes. Data were obtained in the temperature range of 25 to 100 C at pressures ranging from near vacuum to about 20 atmospheres. Results of the experimental effort were compared with the limited data previously reported. As a verification to the applicability of results to actual bladder systems, counter diffusion tests were performed with a laminated sample containing aluminum foil with a selected group of holes.

  9. Evaluation of Container Closure System Integrity for Frozen Storage Drug Products.

    PubMed

    Nieto, Alejandra; Roehl, Holger; Brown, Helen; Nikoloff, Jonas; Adler, Michael; Mahler, Hanns-Christian

    2016-01-01

    Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Shipment of frozen product could potentially be performed in the frozen state, yet possibly at different temperatures, for example, using dry ice (-80 °C). Container closure systems of drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Below their Tg, rubber stoppers are known to lose their elastic properties and become brittle, and thus potentially fail to maintain container closure integrity in the frozen state. Leaks during frozen temperature storage and transportation are likely to be transient, yet, can possibly risk container closure integrity and lead to microbial contamination. After thawing, the rubber stopper is supposed to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal physical container closure integrity) for direct assessment of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, different container closure systems were evaluated with regard to physical container closure integrity in the frozen state to assess the suitability of vial/stopper combinations and were compared to a gas headspace method. In summary, the thermal physical container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. Sometimes, drug product for parenteral administration is stored in a frozen state (e.g., -20 °C or -80 °C), particularly during early stages of development of some biotech molecules in order to provide sufficient stability. Container closure systems for drug products usually consist of a glass vial, rubber stopper, and an aluminum crimped cap. In the frozen state, the glass transition temperature (Tg) of commonly used rubber stoppers is between -55 and -65 °C. Leaks during frozen temperature storage and transportation are likely to be transient, yet they can possibly risk container closure integrity and lead to microbial contamination and sterility breach. After thawing, the rubber stopper is expected to re-seal the container closure system. Given the transient nature of the possible impact on container closure integrity in the frozen state, typical container closure integrity testing methods (used at room temperature conditions) are unable to evaluate and thus confirm container closure integrity in the frozen state. Here we present the development of a novel method (thermal container closure integrity) for direct measurement of container closure integrity by a physical method (physical container closure integrity) at frozen conditions, using a modified He leakage test. In this study, we found that the thermal container closure integrity He leakage method was more sensitive in detecting physical container closure integrity impact than gas headspace and aided identification of an unsuitable container closure system. © PDA, Inc. 2016.

  10. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    NASA Astrophysics Data System (ADS)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  11. 75 FR 17169 - Nextera Energy Duane Arnold, LLC, Duane Arnold Energy Center; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... leakage from the overall integrated leak rate test measurement. Main steam leakage includes leakage... integrated leakage rate (Type A) test measurement and from the sum of the leakage rates from local leakage... leakage rate (Type A) test [[Page 17170

  12. AN-Type Fittings in the International Space System (ISS) Node 2 Ammonia System Technical Assessment Report

    NASA Technical Reports Server (NTRS)

    Cragg, Clinton H.; Dibbern, Andreas W.; Beil, Robert J.; Terrone, Mark; Rotter, Henry A.; Ernest, Steve; Frankenfield, Bruce; Solano, Paul

    2009-01-01

    Based on an anonymous request, an NESC Assessment Team was formed to investigate potential leakage problems from the ISS Program's Node 2 Anhydrous Ammonia System AN fittings. The Team's charter was to provide the ISS Program with a path to follow, which could include testing, to ensure the ISS Program felt confident that the AN fittings' leakage would not exceed specified limits in orbit. The findings from that assessment are contained in this document.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Austin Douglas; Runnels, Joel T.; Moore, Murray E.

    A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canistermore » integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.« less

  14. Bile leakage test in liver resection: A systematic review and meta-analysis

    PubMed Central

    Wang, Hai-Qing; Yang, Jian; Yang, Jia-Yin; Yan, Lu-Nan

    2013-01-01

    AIM: To assess systematically the safety and efficacy of bile leakage test in liver resection. METHODS : Randomized controlled trials and controlled clinical trials involving the bile leakage test were included in a systematic literature search. Two authors independently assessed the studies for inclusion and extracted the data. A meta-analysis was conducted to estimate postoperative bile leakage, intraoperative positive bile leakage, and complications. We used either the fixed-effects or random-effects model. RESULTS: Eight studies involving a total of 1253 patients were included and they all involved the bile leakage test in liver resection. The bile leakage test group was associated with a significant reduction in bile leakage compared with the non-bile leakage test group (RR = 0.39, 95%CI: 0.23-0.67; I2 = 3%). The white test had superiority for detection of intraoperative bile leakage compared with the saline solution test (RR = 2.38, 95%CI: 1.24-4.56, P = 0.009). No significant intergroup differences were observed in total number of complications, ileus, liver failure, intraperitoneal hemorrhage, pulmonary disorder, abdominal infection, and wound infection. CONCLUSION: The bile leakage test reduced postoperative bile leakage and did not increase incidence of complications. Fat emulsion is the best choice of solution for the test. PMID:24363535

  15. Bile leakage test in liver resection: a systematic review and meta-analysis.

    PubMed

    Wang, Hai-Qing; Yang, Jian; Yang, Jia-Yin; Yan, Lu-Nan

    2013-12-07

    To assess systematically the safety and efficacy of bile leakage test in liver resection. Randomized controlled trials and controlled clinical trials involving the bile leakage test were included in a systematic literature search. Two authors independently assessed the studies for inclusion and extracted the data. A meta-analysis was conducted to estimate postoperative bile leakage, intraoperative positive bile leakage, and complications. We used either the fixed-effects or random-effects model. Eight studies involving a total of 1253 patients were included and they all involved the bile leakage test in liver resection. The bile leakage test group was associated with a significant reduction in bile leakage compared with the non-bile leakage test group (RR = 0.39, 95%CI: 0.23-0.67; I (2) = 3%). The white test had superiority for detection of intraoperative bile leakage compared with the saline solution test (RR = 2.38, 95%CI: 1.24-4.56, P = 0.009). No significant intergroup differences were observed in total number of complications, ileus, liver failure, intraperitoneal hemorrhage, pulmonary disorder, abdominal infection, and wound infection. The bile leakage test reduced postoperative bile leakage and did not increase incidence of complications. Fat emulsion is the best choice of solution for the test. © 2013 Baishideng Publishing Group Co., Limited. All rights reserved.

  16. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    PubMed Central

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901

  17. Evaluation of the white test for the intraoperative detection of bile leakage.

    PubMed

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  18. Procedures for Leakage Testing and Disinfection of Containment Bed Isolators and Containment Aircraft Transit Isolators.

    DTIC Science & Technology

    1980-05-01

    the manufacturer are to inflate the isolator to a pressure of 10 mm of water on the gauge and seal off all air lines. If the pressure drops more than 4...results of these tests, it must be borne in mind that the tests were conducted using non-pathogenic Tl coliphage virus and B. subtilis var. niger spores...order as that for Tl coliphage . Also, the procedures described in- clude a large safety factor and would be expected to be adequate to eliminate all

  19. [Effect of Bushen Huoxue Compound on Retinal Müller Cells in High Glucose or AGEs Conditions].

    PubMed

    Xie, Xue-jun; Song, Ming-xia; Zhang, Mei; Qin, Wei; Wan, Li; Fang, Yang

    2015-06-01

    To explore the effect of Bushen Huoxue Compound (BHC) on lactate dehydrogenase (LDH) leakage, expressions of vascular endothelial growth factor (VEGF) and VEGF mRNA in retinal Muller cells under high glucose condition or advanced glycosylation end products (AGEs) condition by using serum pharmacological method. The retinal Müller cells of 5-7 days post-natal Sprague Dawley (SD) rats were cultured with modified enzyme-digestion method. Purified retinal Muller cells were cultured in normal conditions, high glucose condition (50 mmol/L) or AGEs (50 mg/L and 100 mg/L) conditions, and BHC-containing serum was added to culture medium. The LDH leakage and VEGF expressions were measured by enzyme-linked immunosorbent assay (ELISA). In addition, the relative expression of VEGF mRNA was tested by reverse transcription polymerase chain reaction (RT-PCR). Compared with the normal control group, expressions of VEGF and VEGF mRNA were significantly increased in the high glucose group, the low dose AGEs group and the high dose AGEs group (all P < 0.01). The LDH leakage was obviously increased in the high dose AGEs group, when compared with the normal control group and the high glucose group (P < 0.01). The LDH leakage, expressions of VEGF and VEGF mRNA were obviously decreased by BHC-containing serum both in high glucose and AGEs conditions (P < 0.05, P < 0.01). BHC-containing serum had no significant effect on the LDH leakage and expressions of VEGF and VEGF mRNA in normal conditions (P > 0.05). AGEs intervention could obviously lower the stability of Müller cell membrane. Up-regulated expressions of VEGF and VEGF mRNA in cultured Müller cells could be induced by AGEs or high glucose. BHC-containing serum could stabilize the stability of Müller cell membrane, inhibit the transcription of VEGF mRNA and decrease the protein expression of VEGF, which might be one of important mechanisms for preventing and treating diabetic retinopathy.

  20. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.

    PubMed

    Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James

    2017-01-01

    USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.

  1. Aroma Leakage from Orange Juice Packed in Gable-Top Paper Containers for Chilled Distribution.

    PubMed

    Aoki, Risa; Tokuda, Aika; Shigemura, Yasutaka; Mineki, Machiko; Sato, Yoshio

    2017-01-01

    We conducted a study to examine aroma leakage from orange juice packed in gable-top paper containers for chilled distribution. Limonene, an aromatic component of orange juice, was considered as an index compound of aroma leakage, and its seepage on the surface of the container and concentration in the orange juice were measured by GC-MS for 12 commercial samples. After 3 days of storage, limonene was detected on the surface of 8 orange juice containers, and the concentration of limonene in the orange juice was found to have decreased. Thus, limonene leaked through the container within a few days, and the extent of leakage differed between containers, presumably depending upon their barrier properties. In addition, limonene was detected in green tea and milk that was stored together with the unopened orange juice containers at 4℃. The transference of orange aroma into milk was significant, because the contamination of the milk was confirmed by subjective sensory evaluation. This study suggests the possibility of transfer of aroma compounds through paper containers to other beverages.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number ismore » used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.« less

  3. 77 FR 14445 - Leakage Tests on Packages for Shipment of Radioactive Material

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0045] Leakage Tests on Packages for Shipment of..., ``Leakage Tests on Packages for Radioactive Material.'' ADDRESSES: You can access publicly available... Materials--Leakage Tests on Packages for Shipment'' approved February 1998. The NRC staff developed and...

  4. Atmospheric and soil-gas monitoring for surface leakage at the San Juan Basin CO{sub 2} pilot test site at Pump Canyon New Mexico, using perfluorocarbon tracers, CO{sub 2} soil-gas flux and soil-gas hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wells, Arthur W; Diehl, J Rodney; Strazisar, Brian R

    2012-05-01

    Near-surface monitoring and subsurface characterization activities were undertaken in collaboration with the Southwest Regional Carbon Sequestration Partnership on their San Juan Basin coal-bed methane pilot test site near Navajo City, New Mexico. Nearly 18,407 short tons (1.670 × 107 kg) of CO{sub 2} were injected into 3 seams of the Fruitland coal between July 2008 and April 2009. Between September 18 and October 30, 2008, two additions of approximately 20 L each of perfluorocarbon (PFC) tracers were mixed with the CO{sub 2} at the injection wellhead. PFC tracers in soil-gas and in the atmosphere were monitored over a period ofmore » 2 years using a rectangular array of permanent installations. Additional monitors were placed near existing well bores and at other locations of potential leakage identified during the pre-injection site survey. Monitoring was conducted using sorbent containing tubes to collect any released PFC tracer from soil-gas or the atmosphere. Near-surface monitoring activities also included CO{sub 2} surface flux and carbon isotopes, soil-gas hydrocarbon levels, and electrical conductivity in the soil. The value of the PFC tracers was demonstrated when a significant leakage event was detected near an offset production well. Subsurface characterization activities, including 3D seismic interpretation and attribute analysis, were conducted to evaluate reservoir integrity and the potential that leakage of injected CO{sub 2} might occur. Leakage from the injection reservoir was not detected. PFC tracers made breakthroughs at 2 of 3 offset wells which were not otherwise directly observable in produced gases containing 20–30% CO{sub 2}. These results have aided reservoir geophysical and simulation investigations to track the underground movement of CO{sub 2}. 3D seismic analysis provided a possible interpretation for the order of appearance of tracers at production wells.« less

  5. Verification of International Space Station Component Leak Rates by Helium Accumulation Method

    NASA Technical Reports Server (NTRS)

    Underwood, Steve D.; Smith, Sherry L.

    2003-01-01

    Discovery of leakage on several International Space Station U.S. Laboratory Module ammonia system quick disconnects (QDs) led to the need for a process to quantify total leakage without removing the QDs from the system. An innovative solution was proposed allowing quantitative leak rate measurement at ambient external pressure without QD removal. The method utilizes a helium mass spectrometer configured in the detector probe mode to determine helium leak rates inside a containment hood installed on the test component. The method was validated through extensive developmental testing. Test results showed the method was viable, accurate and repeatable for a wide range of leak rates. The accumulation method has been accepted by NASA and is currently being used by Boeing Huntsville, Boeing Kennedy Space Center and Boeing Johnson Space Center to test welds and valves and will be used by Alenia to test the Cupola. The method has been used in place of more expensive vacuum chamber testing which requires removing the test component from the system.

  6. Can the intraoperative leak test prevent postoperative leakage of esophagojejunal anastomosis after total gastrectomy?

    PubMed

    Kanaji, Shingo; Ohyama, Masato; Yasuda, Takashi; Sendo, Hiroyoshi; Suzuki, Satoshi; Kawasaki, Kentaro; Tanaka, Kenichi; Fujino, Yasuhiro; Tominaga, Masahiro; Kakeji, Yoshihiro

    2016-07-01

    Anastomotic failures that cannot be detected during surgery often lead to postoperative leakage. There have been no detailed reports on the intraoperative leak test for esophagojejunal anastomosis. Our purpose was to investigate the utility of routine intraoperative leak testing to prevent postoperative anastomotic leakage after performing esophagojejunostomy. We prospectively performed routine air leak tests and reviewed the records of 185 consecutive patients with gastric cancer who underwent open total gastrectomy followed by esophagojejunostomy. A positive leak test was found for six patients (3.2 %). These patients with positive leak tests were subsequently treated with additional suturing, and they developed no postoperative anastomotic leakage. However, anastomotic leakage occurred in nine patients (4.9 %) with negative leak tests. A multivariate analysis demonstrated that a patient age >75 years and the surgeon's experience <30 cases were risk factors for anastomotic leakage. Intraoperative leak testing can detect some physical dehiscence, and additional suturing may prevent anastomotic leakage. However, it cannot prevent all anastomotic leakage caused by other factors, such as the surgeons' experience and patients' age.

  7. The White test: a new dye test for intraoperative detection of bile leakage during major liver resection.

    PubMed

    Nadalin, Silvio; Li, Jun; Lang, Hauke; Sotiropoulos, Georgios C; Schaffer, Randolph; Radtke, Arnold; Saner, Fuat; Broelsch, Christoph E; Malagó, Massimo

    2008-04-01

    To describe a new intraoperative bile leakage test in patients undergoing a major liver resection aimed to combine the advantages of each of the other standard bile leakage tests (accurate visualization of leaks, reproducibility, and ease of use) without their disadvantages. At the end of the major hepatic resection, 10 to 30 mL of sterile fat emulsion, 5%, is injected via an olive-tip cannula through the cystic duct while manually occluding the distal common bile duct. As the biliary tree fills with fat emulsion solution, leakage of the white fluid is visualized on the raw surface of the liver resection margin. The detected leakages are closed by means of single stitches. Afterwards, the residual fat emulsion on the resection surface is washed off with saline and the White test is repeated to detect and/or exclude additional bile leakages. At the end, residual fat emulsion is washed out from the biliary tract by a low-pressure infusion of saline solution. Intraoperatively, additional potential bile leakages (not seen using a conventional saline bile leakage test) were identified in 74% of our patients. Postoperative bile leakages (within 30 days) occurred in only 5.1% of patients when the White test was used. No adverse effects related to this technique were observed. The White test has clear advantages in comparison with other bile leakage tests: it precisely detects bile leakages, regardless of size; it does not stain the resection surface, allowing it to be washed off and repeated ad infinitum; and it is safe, quick, and inexpensive.

  8. The White-test helps to reduce biliary leakage in liver resection: a systematic review and meta-analysis.

    PubMed

    Linke, Richard; Ulrich, Frank; Bechstein, Wolf O; Schnitzbauer, Andreas A

    2015-01-01

    Bile leakage testing may help to detect and reduce the incidence of biliary leakage after hepatic resection. This review was performed to investigate the value of the White-test in identifying intraoperative biliary leakage and avoiding postoperative leakage. A systematic review and meta-analysis was performed. Two researchers performed literature research. Primary outcome measure was the incidence of post-hepatectomy biliary leakage; secondary outcome measure was the ability of detecting intraoperative biliary leakage with the help of the White-test. A total of 4 publications (including original data from our center) were included in the analysis. Evidence levels of the included studies had medium quality of 2b (individual cohort studies including low quality randomized controlled trials). Use of the White-test led to a significant reduction of post-operative biliary leakage [OR: 0.3 (95% CI: 0.14, 0.63), p = 0.002] and led to a significant higher intraoperative detection of biliary leakages [OR: 0.03 (95%CI: 0.02, 0.07), p < 0.00001]. Existing evidence implicates the use of the White-test after hepatic resection to identify bile leaks intraoperatively and thus reduce incidence of post-operative biliary leakage. Nonetheless, there is a requirement for a high-quality randomized controlled trial with adequately powered sample-size to confirm findings from the above described studies and further increase evidence in this field.

  9. National Aerospace Plane Engine Seals: High Temperature Seal Performance Evaluation

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.

    1991-01-01

    The key to the successful development of the single stage to orbit National Aerospace Plane (NASP) is the successful development of combined cycle ramjet/scramjet engines that can propel the vehicle to 17,000 mph to reach low Earth orbit. To achieve engine performance over this speed range, movable engine panels are used to tailor engine flow that require low leakage, high temperature seals around their perimeter. NASA-Lewis is developing a family of new high temperature seals to form effective barriers against leakage of extremely hot (greater than 2000 F), high pressure (up to 100 psi) flow path gases containing hydrogen and oxygen. Preventing backside leakage of these explosive gas mixtures is paramount in preventing the potential loss of the engine or the entire vehicle. Seal technology development accomplishments are described in the three main areas of concept development, test, and evaluation and analytical development.

  10. Design and implementation of website information disclosure assessment system.

    PubMed

    Cho, Ying-Chiang; Pan, Jen-Yi

    2015-01-01

    Internet application technologies, such as cloud computing and cloud storage, have increasingly changed people's lives. Websites contain vast amounts of personal privacy information. In order to protect this information, network security technologies, such as database protection and data encryption, attract many researchers. The most serious problems concerning web vulnerability are e-mail address and network database leakages. These leakages have many causes. For example, malicious users can steal database contents, taking advantage of mistakes made by programmers and administrators. In order to mitigate this type of abuse, a website information disclosure assessment system is proposed in this study. This system utilizes a series of technologies, such as web crawler algorithms, SQL injection attack detection, and web vulnerability mining, to assess a website's information disclosure. Thirty websites, randomly sampled from the top 50 world colleges, were used to collect leakage information. This testing showed the importance of increasing the security and privacy of website information for academic websites.

  11. 49 CFR 178.47 - Specification 4DS welded stainless steel cylinders for aircraft use.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... be manufactured using equipment and processes adequate to ensure that each cylinder produced conforms... °F ±25° after process treatment and before hydrostatic test. (h) Openings in container. Openings must... a fitting, boss, or pad must be adequate to prevent leakage. Threads must comply with the following...

  12. 49 CFR 178.47 - Specification 4DS welded stainless steel cylinders for aircraft use.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... be manufactured using equipment and processes adequate to ensure that each cylinder produced conforms... °F ±25° after process treatment and before hydrostatic test. (h) Openings in container. Openings must... a fitting, boss, or pad must be adequate to prevent leakage. Threads must comply with the following...

  13. 49 CFR 178.47 - Specification 4DS welded stainless steel cylinders for aircraft use.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... be manufactured using equipment and processes adequate to ensure that each cylinder produced conforms... °F ±25° after process treatment and before hydrostatic test. (h) Openings in container. Openings must... a fitting, boss, or pad must be adequate to prevent leakage. Threads must comply with the following...

  14. Bag Test Measures Leakage From Insulated Pipe

    NASA Technical Reports Server (NTRS)

    Schock, Kent D.; Easter, Barry P.

    1994-01-01

    Test quantifies leakage of gas from pipe even though pipe covered with insulation. Involves use of helium analyzer to measure concentration of helium in impermeable bag around pipe. Test administered after standard soap-solution bubble test indicates presence and general class of leakage.

  15. Contribution of ethylenetetrafluoroethylene (ETFE) insulation to the electrical performance of Riata® silicone leads having externalized conductors.

    PubMed

    Fischer, Avi; Klehn, Russell

    2013-08-01

    The insulation of St. Jude Medical Riata® leads contains a polytetrafluoroethylene (PTFE) liner, silicone tubing, and ethylenetetrafluoroethylene (ETFE) coating on individual cable conductors. ETFE has sufficient dielectric strength to assure electrical function. This investigation intended to analyze performance of leads with and without externalized conductors and with intact and breached ETFE. Testing was performed on ETFE-coated conductors to determine their ability to deliver high-voltage therapy. Tests were performed on samples under different conditions and current leakage was measured. A high-voltage test and a cyclic pulse test were performed, and the effect of lead modifications on the potential gradient from a high-voltage shock was used to determine functionality. Measurements from modified Riata® leads were compared with a control lead with all insulation and conducting elements intact. Current leakage for all conditions tested, was within the acceptance criteria for the high-voltage test and the cyclic pulse test. In conductors that underwent cyclic testing, the highest value of current leakage was within the limit of acceptability for both phases of the test. Testing of leads with externalized conductors and breached ETFE showed similar potential gradients compared with a control lead. Testing of ETFE-coated conductors following multiple preconditioning steps showed that ETFE serves as a redundant layer of insulation. In the event that the ETFE coating is breached, the potential gradient seen resulting from a high-voltage defibrillation shock was similar to a lead with no breach to the ETFE, even after 100 shocks.

  16. Conditioning of the 4 Curies Radium-226 Sealed Radiation Source in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Punnachaiya, M.; Sawangsri, T.; Wanabongse, P.

    This paper describes the conditioning of the 4 curies Radium-226 (Ra-226) sealed radiation source using as a teletherapy unit for cancer treatment in Thailand. The conditioning was under the International Atomic Energy Agency (IAEA) supervision and budgetary supports, comprised of 6 operational steps: the surface dose rate and actual dimension of radium unit measurements, the appropriate lead shielding design with IAEA approval, confirmation of radioactive contamination before conditioning (smear test and radon gas leakage test), transfer of radium source unit into the designed shielding, confirmation of radioactive contamination and dose rate measurement after conditioning, and transportation of Ra-226 conditioning wastemore » package to OAP interim waste storage. The Ra-226 unit was taken out of OAP temporary waste storage for the surface dose rate and the actual dimension measurements behind the 12 inches thick heavy concrete shielding. The maximum measured surface dose rate was 70 R/hr. The special lead container was designed according to its surface dose rate along the source unit which the maximum permissible dose limit for surface dose rate of waste package after conditioning at 2 mSv/hr was applied. The IAEA approved container had total weight of 2.4 ton. After the confirmation of radioactive contamination, Ra-226 source unit was transferred and loaded in the designed lead shielding within 2 minutes. The results of smear test before and after conditioning including radon gas leakage test revealed that there was no radioactive contamination. After conditioning, the surface dose rate measured on the top, bottom were 15,10 mR/hr and varied from 6 - 50 mR/hr around lead container. The Ra-226 conditioning waste package was safely transported to store in OAP interim waste storage. Total working time including the time consumed for radon gas leakage test was 3.5 hours. The total radiation dose received by 16 operators, were ranged from 1 - 69.84 {mu}Sv and the operational team completed the conditioning safely within the effective dose limit for occupational exposure of 50 mSv/year (200 {mu}Sv/day). (authors)« less

  17. Silica particles cause NADPH oxidase–independent ROS generation and transient phagolysosomal leakage

    PubMed Central

    Joshi, Gaurav N.; Goetjen, Alexandra M.; Knecht, David A.

    2015-01-01

    Chronic inhalation of silica particles causes lung fibrosis and silicosis. Silica taken up by alveolar macrophages causes phagolysosomal membrane damage and leakage of lysosomal material into the cytoplasm to initiate apoptosis. We investigated the role of reactive oxygen species (ROS) in this membrane damage by studying the spatiotemporal generation of ROS. In macrophages, ROS generated by NADPH oxidase 2 (NOX2) was detected in phagolysosomes containing either silica particles or nontoxic latex particles. ROS was only detected in the cytoplasm of cells treated with silica and appeared in parallel with an increase in phagosomal ROS, as well as several hours later associated with mitochondrial production of ROS late in apoptosis. Pharmacological inhibition of NOX activity did not prevent silica-induced phagolysosomal leakage but delayed it. In Cos7 cells, which do not express NOX2, ROS was detected in silica-containing phagolysosomes that leaked. ROS was not detected in phagolysosomes containing latex particles. Leakage of silica-containing phagolysosomes in both cell types was transient, and after resealing of the membrane, endolysosomal fusion continued. These results demonstrate that silica particles can generate phagosomal ROS independent of NOX activity, and we propose that this silica-generated ROS can cause phagolysosomal leakage to initiate apoptosis. PMID:26202463

  18. Determination of the Apical Sealing Abilities of Mineral Trioxide Aggregate, Portland Cement, and Bioaggregate After Irrigation with Different Solutions.

    PubMed

    Bayram, H Melike; Saklar, Feridun; Bayram, Emre; Orucoglu, Hasan; Bozkurt, Alperen

    2015-06-01

    The purpose of this study was to investigate the sealing ability of root-end filling materials such as mineral trioxide aggregate (MTA), Portland cement, and bioaggregate (BA) after irrigation with different solutions. We examined 130 human maxillar central teeth. After cutting the teeth at the cementoenamel junction, the root canals were expanded using nickel-titanium rotary instruments. Root canals were filled with AH-plus and gutta-percha. Then, the roots were cut apically, and 3 mm deep retrograde cavities were prepared. The roots were divided 12 experimental groups, consisting 10 teeth each; the positive and negative control groups contained five teeth each. The retrograde cavities were rinsed using ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), BioPure(™) mixture of a tetracycline isomer, an acid, and a detergent (MTAD), or distilled water. Next, groups 1, 2, 3, and 4 were sealed with MTA; groups 5, 6, 7, and 8 were sealed with Portland cement; and groups 9, 10, 11, and 12 were sealed with BA. Then, apical microleakage was evaluated by using a computerized fluid filtration method. The results of the leakage test were statistically evaluated by the post-hoc Tukey's test. MTA, Portland cement, and BA root-end filling materials showed the least leakage in the CHX and distilled water groups. The highest leakage was observed in the EDTA and MTAD groups. The sealing ability of BA was as good as that of MTA. EDTA and MTAD increased the apical leakage and CHX and distilled water decreased the leakage of the root-end filling materials examined in this study.

  19. Acoustic building infiltration measurement system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muehleisen, Ralph T.; Raman, Ganesh

    Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

  20. 49 CFR 176.710 - Care following leakage or sifting of radioactive materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... segregated from unnecessary contact with personnel. In case of obvious leakage, or if the inside container appears to be damaged, the stowage area (hold, compartment, or deck area) containing this cargo must be... contact, inhalation, or ingestion. No person may handle the material or remain in the vicinity unless...

  1. Quasi-steady Bingham plastic analysis of an electrorheological flow mode bypass damper with piston bleed

    NASA Astrophysics Data System (ADS)

    Lindler, Jason; Wereley, Norman M.

    2003-06-01

    We present an improved experimental validation of our nonlinear quasi-steady electrorheological (ER) and magnetorheological damper analysis, using an idealized Bingham plastic shear flow mechanism, for the flow mode of damper operation with leakage effect. To validate the model, a double-acting ER valve or bypass damper was designed and fabricated. Both the hydraulic cylinder and the bypass duct have cylindrical geometry, and damping forces are developed in the annular bypass via Poiseuille flow. The ER fluid damper contains a controlled amount of leakage around the piston head. The leakage allows ER fluid to flow from one side of the piston head to the opposite side without passing through the ER bypass. For this flow mode damper, the damping coefficient, defined as the ratio of equivalent viscous damping of the Bingham plastic material, Ceq, to the Newtonian viscous damping, C, is a function of the non-dimensional plug thickness only. The damper was tested for varying conditions of applied electric field and frequency using a mechanical damper dynamometer. In this analysis, the leakage damping coefficient with incorporated leakage effects, predict the amount of energy dissipated for a complete cycle of the piston rod. Measured force verses displacement cycles for multiple frequencies and electric fields validate the ability of the non-dimensional groups and the leakage damping coefficient to predict the damping levels for an ER bypass damper with leakage. Based on the experimental validation of the model using these data, the Bingham plastic analysis is shown to be an effective tool for the analysis-based design of double-acting ER bypass dampers.

  2. Predicting Envelope Leakage in Attached Dwellings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faakye, O.; Arena, L.; Griffiths, D.

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less

  3. 49 CFR 180.605 - Requirements for periodic testing, inspection and repair of portable tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tank shows evidence of dents, corroded or abraded areas, leakage, or any other condition that might... transported; a leakage test; and a test of the satisfactory operation of all service equipment. Sheathing... material, the internal examination may be waived if it is leakage tested in accordance with the procedures...

  4. The SSME seal test program: Leakage tests for helically-grooved seals

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1983-01-01

    Helically grooved annular seal configurations were tested in highly turbulent flow to determine if reduced leakage and enhanced stability would result from the pumping action of the seal. It was found that: (1) leakage of a helically grooved seals decreases with running speed; (2) leakage reduction due to increased running speed is greater at lower values of R sub a; (3) an asymptote for leakage reduction is indicated with increasing running speed; (4) leakage is reduced by reducing the ridge (minimum) and average clearances; (5) leakage increases with increasing pitch angles and with increasing groove depth. Plain seals with smooth rotors and stators will leak more than a helically grooved seal. It was also found that plain seals with a rough rotor and a rough stator leak less than a properly designed helically grooved seal. A properly designed helically grooved seal consumes at least twice as much power as a conventional annular seal.

  5. Technology Solutions Case Study: Predicting Envelope Leakage in Attached Dwellings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-11-01

    The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Althoughmore » the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.« less

  6. Posttest destructive examination of the steel liner in a 1:6-scale reactor containment model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lambert, L.D.

    A 1:6-scale model of a nuclear reactor containment model was built and tested at Sandia National Laboratories as part of research program sponsored by the Nuclear Regulatory Commission to investigate containment overpressure test was terminated due to leakage from a large tear in the steel liner. A limited destructive examination of the liner and anchorage system was conducted to gain information about the failure mechanism and is described. Sections of liner were removed in areas where liner distress was evident or where large strains were indicated by instrumentation during the test. The condition of the liner, anchorage system, and concretemore » for each of the regions that were investigated are described. The probable cause of the observed posttest condition of the liner is discussed.« less

  7. Magnetic Heat Pump Containing Flow Diverters

    NASA Technical Reports Server (NTRS)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  8. Design and Implementation of Website Information Disclosure Assessment System

    PubMed Central

    Cho, Ying-Chiang; Pan, Jen-Yi

    2015-01-01

    Internet application technologies, such as cloud computing and cloud storage, have increasingly changed people’s lives. Websites contain vast amounts of personal privacy information. In order to protect this information, network security technologies, such as database protection and data encryption, attract many researchers. The most serious problems concerning web vulnerability are e-mail address and network database leakages. These leakages have many causes. For example, malicious users can steal database contents, taking advantage of mistakes made by programmers and administrators. In order to mitigate this type of abuse, a website information disclosure assessment system is proposed in this study. This system utilizes a series of technologies, such as web crawler algorithms, SQL injection attack detection, and web vulnerability mining, to assess a website’s information disclosure. Thirty websites, randomly sampled from the top 50 world colleges, were used to collect leakage information. This testing showed the importance of increasing the security and privacy of website information for academic websites. PMID:25768434

  9. Method and apparatus for container leakage testing

    DOEpatents

    Kronberg, James W.

    1995-01-01

    An apparatus for use in one-hundred percent leak testing of food containers used in conjunction with a tracer gas. The apparatus includes a shell with entrance and exit air locks to create a controlled atmosphere through which a series of containers is conveyed by a conveyor belt. The pressure in the shell is kept lower than the pressure in the containers and the atmosphere is made to flow with the containers so that a tracer gas placed in the packages before sealing them will leak more readily, but the leaked tracer gas will remain associated with the leaking package as it moves through the shell. The leaks are detected with a sniffer probe in fluid communication with a gas chromatograph. The gas chromatograph issues a signal when it detects a leak to an ejector that will eject the leaking container from the conveyor. The system is timed so that the series of containers can move continuously into and out of the shell, past the probe and the ejector, without stopping, yet each package is tested for leaks and removed if leaking.

  10. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases B Appendix B to Part 180... Pt. 180, App. B Appendix B to Part 180—Acceptable Internal Self-closing Stop Valve Leakage Tests for.... (b) Internal Self-Closing Stop Valve Test. An operator of a cargo tank that is not equipped with a...

  11. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases B Appendix B to Part 180... Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases For internal self-closing stop valve...

  12. 47 CFR 76.1700 - Records to be maintained by cable system operators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... programming); § 76.1704 (proof-of-performance test data); and § 76.1706 (signal leakage logs and repair... children's programming); § 76.1704 (proof-of-performance test data); and § 76.1706 (signal leakage logs and... programming); § 76.1704 (proof-of-performance test data); and § 76.1706 (signal leakage logs and repair...

  13. Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box

    NASA Technical Reports Server (NTRS)

    Glass, David E.

    1998-01-01

    A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.

  14. Influence of thermal aging on AC leakage current in XLPE insulation

    NASA Astrophysics Data System (ADS)

    Geng, Pulong; Song, Jiancheng; Tian, Muqin; Lei, Zhipeng; Du, Yakun

    2018-02-01

    Cross-linked polyethylene (XLPE) has been widely used as cable insulation material because of its excellent dielectric properties, thermal stability and solvent resistance. To understand the influence of thermal aging on AC leakage current in XLPE insulation, all XLPE specimens were aged in oven in temperature range from 120 °C to 150 °C, and a series of tests were conducted on these XLPE specimens in different aging stages to measure the characteristic parameters, such as complex permittivity, leakage current and complex dielectric modulus. In the experiments, the effects of thermal aging, temperature and frequency on the AC leakage current in XLPE insulation were studied by analyzing complex dielectric constant and dielectric relaxation modulus spectrum, the change of relaxation peak and activation energy. It has been found that the active part of leakage current increases sharply with the increase of aging degree, and the test temperature and frequency have an influence on AC leakage current but the influence of test temperature is mainly reflected in the low frequency region. In addition, it has been shown by the experiments that the reactive part of leakage current exhibits a strong frequency dependent characteristic in the testing frequency range from 10-2 Hz to 105 Hz, but the influence of test temperature and thermal aging on it is relatively small.

  15. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Acceptable Internal Self-closing Stop Valve... Pt. 180, App. B Appendix B to Part 180—Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases For internal self-closing stop valve leakage testing...

  16. Modeling the Fate of Groundwater Contaminants Resulting from Leakage of Butanol-blended Fuel

    EPA Science Inventory

    The poster demonstrates the integration of MODFLOW2000 and modified RT3D, simulating flow and transport of remediation process results from leakage of Butanol and Benzene contained in alternative fuels.

  17. Evaluating the use of PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of nuclear canister filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Murray E.

    This document details the distinction between using PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of filters. This document is developed to justify the use of PAO rather than DOP for evaluating the performance of filters in the SAVY 4000 and Hagan containers. The design criteria (Anderson et al, 2012) for purchasing SAVY 4000 containers and the Safety Analysis Report for the SAVY 4000 Container Series specified that the filter must “capture greater than 99.97% of 0.45 μm mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentrationmore » of 65±15 micrograms per liter.”This corresponds to a leakage percent of 0.03% (3.0x10 -2). The density of DOP oil is 985 kg/m 3 and the density of PAO oil is 819 kg/m 3. ATI Test Inc measured the mass mean diameter of aerosol distributions produced by a single Laskin type III-A nozzle operating at a 20 psig air pressure as 0.563 μm for DOP oil and 0.549 μm for PAO oil. (See Appendix A.) For both types of oil in this document, the single fiber method calculated the leakage percent to be 4.4x10 -5 for DOP oil and 4.7x10 -5 for PAO oil. Although the percent error between these two quantities is 7.7%, these calculated leakage percent values are more than two orders of magnitude less than the criterion specified in the SAVY canister SAR. As a point of reference, the photometer used to measure the SAVY canister filter performance cannot resolve values for the leakage percent below 1.0x10 -5. Additionally, over a range of particle sizes from 0.01 μm to 3.0 μm, there was less than 4.0x10 -5 error between the calculated filter efficiency for the two types of oil at any particular particle size diameter. In conclusion, the difference between using DOP and PAO for testing SAVY canister filters is of inconsequential concern.« less

  18. In vitro and ex vivo microbial leakage assessment in endodontics: A literature review.

    PubMed

    Savadkouhi, Sohrab Tour; Bakhtiar, Hengameh; Ardestani, Safoura Emami

    2016-01-01

    The aim of this study was to perform a literature review of published in-vitro and ex-vivo studies, which evaluated microbial leakage in endodontics in the past 10 years. A comprehensive electronic literature search was carried out in PubMed database for English articles published from 2005 to 2016 using the keywords "endodontics," " in vitro ," " ex vivo ," "microbial leakage," "microbial penetration," "saliva," " Enterococcus faecalis ," " E. faecalis ," "endodontic sealers," "temporary filling material," "apical plug," "mineral trioxide aggregate," and "MTA." The keywords were combined using Boolean operators AND/OR. Based on our search strategy, 33 relevant articles were included in the study. There are three main methods for assessment of bacterial microleakage, namely, (A) the dual-chamber leakage model, (B) detection of bacteria using a scanning electron microscope (SEM), and (C) polymerase chain reaction. All bacterial leakage models have some limitations and may yield different results compared to other microleakage evaluation techniques (i.e., dye penetration, fluid filtration, or electrochemical tests). The results of SEM correlated with those of microbial leakage test in most studies. Microbial leakage test using saliva better simulates the clinical setting for assessment of the leakage of single or mixed bacterial species.

  19. SENSITIVITY OF THE HOUSE PRESSURE TEST FOR DUCT LEAKAGE TO VARIATIONS IN THE DISTRIBUTION OF AIR LEAKAGE IN THE HOUSE ENVELOPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ANDREWS,J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge bymore » 50% or more.« less

  20. Energy Efficient High-Pressure Turbine Leakage Technology Report

    NASA Technical Reports Server (NTRS)

    Gardner, W. B.

    1980-01-01

    The leakage test program was one of such supporting technology programs structured to provide guidance to the Energy Efficient Engine High Pressure Turbine Component Design Effort. Leakage reduction techniques were identified and evaluated. Test models were used to simulate component leak paths and to evaluate leakage reduction techniques. These models simulated the blade/disk attachment, the vane inner platform attachment, and the vane outer platform attachment combined with the blade outer airseal. Disk blade attachment testing indicated that leakage in this area could be reduced to very low levels by paying careful attention to the tolerances along the contact surface between the blade vibration damper and the blade platform contact surface. The aim of feather seal testing was to achieve a goal for an effective leakage gap of one mil (.001 inch) per inch of feather seal length. Results indicated that effective gaps even below the goal level were achievable by (1) maintaining close tolerances between feather seals and their slots to minimize end gaps and limit seal rotation, (2) avoiding feather seal overlap, and (3) minimizing feather seal intersections. W seals were shown to be effective leakage control devices. Wire rope, in its present state of development, was shown not to be an effective sealing concept for application to the component design.

  1. Nuclear power plant prestressed concrete containment vessel structure monitoring during integrated leakage rate test using three kinds of fiber optic sensors

    NASA Astrophysics Data System (ADS)

    Liao, Kaixing; Li, Jinke; Kong, Xianglong; Sun, Changsen; Zhao, Xuefeng

    2017-04-01

    After years of operation, the safety of the prestressed concrete containment vessel (PCCV) structure of Nuclear Power Plant (NPP) is an important aspect. In order to detect the strength degradation and the structure deformation, several sensors such as vibrating wire strain gauge, invar wires and pendulums were installed in PCCV. However, the amounts of sensors above are limited due to the cost. Due to the well durability of fiber optic sensors, three kinds of fiber optic sensors were chosen to install on the surface of PCCV to monitor the deformation during Integrated Leakage Rate Test (ILRT). The three kinds of fiber optic sensors which had their own advantages and disadvantages are Fiber Bragg Grating (FBG), white light interferometry (WLI) and Brillouin Optical Time Domain Analysis (BOTDA). According to the measuring data, the three fiber optic sensors worked well during the ILRT. After the ILRT, the monitoring strain was recoverable thus the PCCV was still in the elastic stage. If these three kinds of fiber optic sensors are widely used in the PCCV, the unusual deformations are easier to detect. As a consequence, the three fiber optic sensors have good potential in the structure health monitoring of PCCV.

  2. Module Hipot and ground continuity test results

    NASA Technical Reports Server (NTRS)

    Griffith, J. S.

    1984-01-01

    Hipot (high voltage potential) and module frame continuity tests of solar energy conversion modules intended for deployment into large arrays are discussed. The purpose of the tests is to reveal potentially hazardous voltage conditions in installed modules, and leakage currents that may result in loss of power or cause ground fault system problems, i.e., current leakage potential and leakage voltage distribution. The tests show a combined failure rate of 36% (69% when environmental testing is included). These failure rates are believed easily corrected by greater care in fabrication.

  3. Field demonstration of CO2 leakage detection in potable aquifers with a pulselike CO2-release test.

    PubMed

    Yang, Changbing; Hovorka, Susan D; Delgado-Alonso, Jesus; Mickler, Patrick J; Treviño, Ramón H; Phillips, Straun

    2014-12-02

    This study presents two field pulselike CO2-release tests to demonstrate CO2 leakage detection in a shallow aquifer by monitoring groundwater pH, alkalinity, and dissolved inorganic carbon (DIC) using the periodic groundwater sampling method and a fiber-optic CO2 sensor for real-time in situ monitoring of dissolved CO2 in groundwater. Measurements of groundwater pH, alkalinity, DIC, and dissolved CO2 clearly deviated from their background values, showing responses to CO2 leakage. Dissolved CO2 observed in the tests was highly sensitive in comparison to groundwater pH, DIC, and alkalinity. Comparison of the pulselike CO2-release tests to other field tests suggests that pulselike CO2-release tests can provide reliable assessment of geochemical parameters indicative of CO2 leakage. Measurements by the fiber-optic CO2 sensor, showing obvious leakage signals, demonstrated the potential of real-time in situ monitoring of dissolved CO2 for leakage detection at a geologic carbon sequestration (GCS) site. Results of a two-dimensional reactive transport model reproduced the geochemical measurements and confirmed that the decrease in groundwater pH and the increases in DIC and dissolved CO2 observed in the pulselike CO2-release tests were caused by dissolution of CO2 whereas alkalinity was likely affected by carbonate dissolution.

  4. 49 CFR 180.407 - Requirements for test and inspection of specification cargo tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... dents, cuts, gouges, corroded or abraded areas, leakage, or any other condition that might render it... accordance with the criteria prescribed in § 180.411. Any signs of leakage must be repaired in accordance...: All lined cargo tanks transporting lading corrosive to the tank September 1, 1991 1 year. Leakage Test...

  5. Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience.

    PubMed

    Han, Don-Hee; Lee, Jinheon

    2005-10-01

    Korean certification regulation for particulate filtering respirators requires inward leakage (IL) or total inward leakage (TIL) testing according to European Standard EN 13274-1, and the standard levels of compliance are similar to those of the European Standard. This study was conducted to evaluate particulate filtering respirators being commercially used in the Korean market using an IL or TIL test and the validity of standard level in Korea. Three half masks and 10 filtering facepieces (two top class, four 1st class and four 2nd class)-a total of 13 brand name respirators-were selected for the test with panels of 10 subjects. Each subject was classified with nine facial dimension grid squares in accordance with face length and lip length. IL or TIL testing was conducted at the laboratory of the 3M Innovation Center in which the experimental instruments and systems were established in compliance with European standards. The testing procedure followed EN 13274-1 (2001). As expected, leakages of half masks were less than those of filtering facepieces and the latter were significantly different among brands. TILs of the 1st class filtering facepieces were found to be much more than those of the 2nd class and the result may cause a wearer to get confused when selecting a mask. The main route leakage for filtering facepieces may not be the filter medium but the face seal. Therefore, it is necessary to develop well-fitting filtering facepieces for Koreans. Because leakages were significantly different for different facial dimensions, a defined test panel for IL or TIL testing according to country or race should be developed. A more precise method to demonstrate fit, for example, fit testing such as in the US regulations, will be needed before IL or TIL testing or when selecting a respirator. Another finding implies that geometric mean of five exercises for IL or TIL may be better than arithmetic mean to establish a standard individual subject mean.

  6. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology.

    PubMed

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.

  7. Large diameter metal ring seal prevents gas leakage at 5000 psi

    NASA Technical Reports Server (NTRS)

    Middelkoop, J. H.

    1966-01-01

    Large metal ring seal prevents gas leakage in hydrogen, helium, or nitrogen storage bottles at pressures up to 5,000 psi. The grooved ring seal which contains elastomer O-rings is installed between the mating faces of the access cover and the storage bottle.

  8. ERROR REDUCTION IN DUCT LEAKAGE TESTING THROUGH DATA CROSS-CHECKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ANDREWS, J.W.

    1998-12-31

    One way to reduce uncertainty in scientific measurement is to devise a protocol in which more quantities are measured than are absolutely required, so that the result is over constrained. This report develops a method for so combining data from two different tests for air leakage in residential duct systems. An algorithm, which depends on the uncertainty estimates for the measured quantities, optimizes the use of the excess data. In many cases it can significantly reduce the error bar on at least one of the two measured duct leakage rates (supply or return), and it provides a rational method ofmore » reconciling any conflicting results from the two leakage tests.« less

  9. Investigation of mercury thruster isolators. [service life

    NASA Technical Reports Server (NTRS)

    Mantenieks, M. A.

    1973-01-01

    Mercury ion thruster isolator lifetime tests were performed using different isolator materials and geometries. Tests were performed with and without the flow of mercury through the isolators in an oil diffusion pumped vacuum facility and cryogenically pumped bell jar. The onset of leakage current in isolators tested occurred in time intervals ranging from a few hours to many hundreds of hours. In all cases, surface contamination was responsible for the onset of leakage current and subsequent isolator failure. Rate of increase of leakage current and the leakage current level increased approximately exponentially with isolator temperature. Careful attention to shielding techniques and the elimination of sources of metal oxides appear to have eliminated isolator failures as a thruster life limiting mechanism.

  10. Anticardiolipin antibodies from syphilis and systemic lupus erythematosus induce leakage in cardiolipin vesicles.

    PubMed

    Gremião, M P; Celli, C M; Chaimovich, H

    1996-04-01

    Anticardiolipin antibodies from sera of patients with systemic lupus erythematosus or syphilis induced leakage of entrapped carboxyfluorescein (CF) from cardiolipin (CL)/phosphatidylcholine(PC) vesicles prepared by sonication of equimolar mixtures of CL:PC. The sera dilution used here was 1:7500. IgG (5-20 micrograms/ml) from the same sera, not containing beta 2GPI, also produced a concentration-dependent leak. Vesicle leakage was inhibited by salt and was not detected with vesicles prepared exclusively with phosphatidylcholine. The demonstration of antibody-induced vesicle leakage offers a convenient system to investigate the mechanism of antibody-lipid binding as well as a potential diagnostic tool.

  11. Effect of Post-HALT Annealing on Leakage Currents in Solid Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2010-01-01

    Degradation of leakage currents is often observed during life testing of tantalum capacitors and is sometimes attributed to the field-induced crystallization in amorphous anodic tantalum pentoxide dielectrics. However, degradation of leakage currents and the possibility of annealing of degraded capacitors have not been investigated yet. In this work the effect of annealing after highly accelerated life testing (HALT) on leakage currents in various types of solid tantalum capacitors was analyzed. Variations of leakage currents with time during annealing at temperatures from 125 oC to 180 oC, thermally stimulated depolarization (TSD) currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. Annealing resulted in a gradual decrease of leakage currents and restored their initial values. Repeat HALT after annealing resulted in reproducible degradation of leakage currents. The observed results are explained based on ionic charge instability (drift/diffusion of oxygen vacancies) in the tantalum pentoxide dielectrics using a modified Schottky conduction mechanism.

  12. Sealing ability of root-end filling materials.

    PubMed

    Amezcua, Octávio; Gonzalez, Álvaro Cruz; Borges, Álvaro Henrique; Bandeca, Matheus Coelho; Estrela, Cyntia Rodrigues de Araújo; Estrela, Carlos

    2015-03-01

    The aim of this research was to compare the apical sealing ability of different root-end filling materials (SuperEBA(®), ProRoot MTA(®), thermoplasticized gutta-percha + AH-Plus(®), thermoplasticized RealSeal(®)), by means of microbial indicators. Thus, 50 human single-rooted teeth were employed, which were shaped until size 5 0, retro - prepared with ultrasonic tips and assigned to 4 groups, retro-filled with each material or controls. A platform was employed, which was split in two halves: upper chamber-where the microbial suspension containing the biological indicators was introduced (E. faecalis + S. aureus + P. aeruginosa + B. subtilis + C. albicans); and a lower chamber containing the culture medium brain, heart influsion, where 3 mm of the apical region of teeth were kept immersed. Lectures were made daily for 60 days, using the turbidity of the culture medium as indicative of microbial contamination. Statistical analyses were carried out at 5% level of significance. The results showed microbial leakage at least in some specimens in all of the groups. RealSeal(®) has more microbial leakage, statistically significant, compared to ProRoot(®) MTA and SuperEBA(®). No significant differences were observed when compared ProRoot(®) MTA and SuperEBA(®). The gutta-percha + AH Plus results showed no statistically significant differences when compared with the other groups. All the tested materials showed microbial leakage. Root-end fillings with Super-EBA or MTA had the lowest bacterial filtration and RealSeal shows highest bacterial filtration.

  13. 76 FR 40937 - Biweekly Notice; Applications and Amendments to Facility Operating Licenses Involving No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... Generator Water Level High-High'' instrument setpoint and associated allowable value. The proposed change is... [Pressurized-Water Reactor] PWR Operability Requirements and Actions for RCS Leakage Instrumentation''. Basis... monitor is the containment atmospheric gaseous radiation monitor. The monitoring of RCS leakage is not a...

  14. Osmotic Stressing, Membrane Leakage, and Fluorescence: An Introductory Biochemistry Demonstration

    ERIC Educational Resources Information Center

    Seu, Kalani J.

    2015-01-01

    A fluorescence demonstration is described that incorporates several fundamental aspects of an introductory biochemistry course. A variation of a known leakage assay is utilized to prepare vesicles containing a quenched fluorophore. The vesicles are exposed to several osmotic environments ranging from isotonic to hypotonic. The degree of vesicle…

  15. Health, Safety, and Environmental Screening and Ranking Frameworkfor Geologic CO2 Storage Site Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Curtis M.

    2005-09-19

    This report describes a screening and ranking framework(SRF) developed to evaluate potential geologic carbon dioxide (CO2) storage sites on the basis of health, safety, and environmental (HSE) risk arising from possible CO2 leakage. The approach is based on the assumption that HSE risk due to CO2 leakage is dependent on three basic characteristics of a geologic CO2 storage site: (1) the potential for primary containment by the target formation; (2) the potential for secondary containment if the primary formation leaks; and (3) the potential for attenuation and dispersion of leaking CO2 if the primary formation leaks and secondary containment fails.more » The framework is implemented in a spreadsheet in which users enter numerical scores representing expert opinions or general information available from published materials along with estimates of uncertainty to evaluate the three basic characteristics in order to screen and rank candidate sites. Application of the framework to the Rio Visa Gas Field, Ventura Oil Field, and Mammoth Mountain demonstrates the approach. Refinements and extensions are possible through the use of more detailed data or model results in place of property proxies. Revisions and extensions to improve the approach are anticipated in the near future as it is used and tested by colleagues and collaborators.« less

  16. Feasibility study of negative lift circumferential type seal for helicopter transmissions

    NASA Technical Reports Server (NTRS)

    Goldring, E. N.

    1977-01-01

    A new seal concept, the negative lift circumferential type seal, was evaluated under simulated helicopter transmission conditions. The bore of the circumferential seal contains step type geometry which produces a negative lift that urges the sealing segments towards the shaft surface. The seal size was a 2.5 inch bore and the test speeds were 7000 and 14,250 rpm. During the 300 hour test at typical transmission seal pressure (to 2 psig) the leakage was within acceptable limits and generally less than 0.1 cc/hour during the last 150 hours of testing. The wear to the carbon segments during the 300 hours was negligible.

  17. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2004-01-01

    Advanced brush and finger seal technologies offer reduced leakage rates over conventional labyrinth seals used in gas turbine engines. To address engine manufacturers concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature Turbine Seal Test Rig. Leakage and power loss test results are compared for these competing seals for operating conditions up to 922 K (1200 F) inlet air temperature, 517 KPa (75 psid) across the seal, and surface velocities up to 366 m/s (1200 ft/s).

  18. Hydrogeology from 10,000 ft below: lessons learned in applying pulse testing for leakage detection in a carbon sequestration formation

    NASA Astrophysics Data System (ADS)

    Sun, A. Y.; Lu, J.; Hovorka, S. D.; Freifeld, B. M.; Islam, A.

    2015-12-01

    Monitoring techniques capable of deep subsurface detection are desirable for early warning and leakage pathway identification in geologic carbon storage formations. This work investigates the feasibility of a leakage detection technique based on pulse testing, which is a traditional hydrogeological characterization tool. In pulse testing, the monitoring reservoir is stimulated at a fixed frequency and the acquired pressure perturbation signals are analyzed in the frequency domain to detect potential deviations in the reservoir's frequency domain response function. Unlike traditional time-domain analyses, the frequency-domain analysis aims to minimize the interference of reservoir noise by imposing coded injection patterns such that the reservoir responses to injection can be uniquely determined. We have established the theoretical basis of the approach in previous work. Recently, field validation of this pressure-based, leakage detection technique was conducted at a CO2-EOR site located in Mississippi, USA. During the demonstration, two sets of experiments were performed using 90-min and 150-min pulsing periods, for both with and without leak scenarios. Because of the lack of pre-existing leakage pathways, artificial leakage CO2 was simulated by rate-controlled venting from one of the monitoring wells. Our results show that leakage events caused a significant deviation in the amplitude of the frequency response function, indicating that pulse testing may be used as a cost-effective monitoring technique with a strong potential for automation.

  19. Influence of the internal anatomy on the leakage of root canals filled with thermoplastic technique.

    PubMed

    Al-Jadaa, Anas; Attin, T; Peltomäki, T; Heumann, C; Schmidlin, P R; Paquè, F

    2018-04-01

    The aim of this paper is to evaluate the influence of the internal anatomy on the leakage of root canals filled with the thermoplastic technique. The upper central incisors (UCI) and mesial roots of the lower molars (MRLM) (n = 12 each) were tested regarding leakage using the gas-enhanced permeation test (GEPT) after root filling. The quality of the root fillings was assessed using micro-computed tomography (μCT) by superimposing scans before and after treatment to calculate unfilled volume. The calculated void volume was compared between the groups and correlated to the measured leakage values. Data were analyzed using t test and Pearson's correlation tests (p < 0.05). The mean void volume did not differ between UCI and MRLM (13.7 ± 6.2% vs. 14.2 ± 6.8%, respectively). However, significantly more leakage was evident in the MRLM (p < 0.001). While the leakage correlated highly to the void volume in the MRLM group (R 2  = 0.981, p < 0.001), no correlation was found in UCI (R 2  = 0.467, p = 0.126). MRLM showed higher leakage values, which correlated to the void volume in the root canal fillings. Care should always be taken while doing root canal treatments, but attention to teeth with known/expected complex root canal anatomy should be considered.

  20. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables.

    PubMed

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables.

  1. A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables

    PubMed Central

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables. PMID:22368483

  2. Large eddy simulation of tip-leakage flow in an axial flow fan

    NASA Astrophysics Data System (ADS)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol; Kwon, Oh-Kyoung

    2016-11-01

    An axial flow fan with a shroud generates a complicated tip-leakage flow by the interaction of the axial flow with the fan blades and shroud near the blade tips. In this study, large eddy simulation is performed for tip-leakage flow in a forward-swept axial flow fan inside an outdoor unit of an air-conditioner, operating at the design condition of the Reynolds number of 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame is adopted. The present simulation clearly reveals the generation and evolution of tip-leakage vortex near the blade tip by the leakage flow. At the inception of the leakage vortex near the leading edge of the suction-side of the blade tip, the leakage vortex is composed of unsteady multiple vortices containing high-frequency fluctuations. As the leakage vortex develops downstream along a slant line toward the following blade, large and meandering movements of the leakage vortex are observed. Thus low-frequency broad peaks of velocity and pressure occur near the pressure surface. Supported by the KISTI Supercomputing Center (KSC-2016-C3-0027).

  3. Is routine postoperative gastrografin study needed after laparoscopic sleeve gastrectomy? Experience of 712 cases.

    PubMed

    Wahby, M; Salama, A F; Elezaby, A F; Belgrami, F; Abd Ellatif, M E; El-Kaffas, H F; Al-Katary, M

    2013-11-01

    The current standard of care is to perform a postoperative gastrografin study following laparoscopic sleeve gastrectomy (LSG) to detect leakage or obstruction. This study evaluated the usefulness of this routine procedure. A retrospective chart review was performed in December 2012. All patients had routine intraoperative methylene blue testing to check for possible leakage from the staple line, and any leaking points were oversewn. We also performed postoperative contrast study (gastrografin) routinely in the first 24-48 h for all patients. From June 2007 to December 2012, 712 cases underwent LSG during the study period. Patients included in this study were 556 women (78.1%) and 156 men (21.9%). The mean age was 35 years. The mean BMI was 48 kg/m2. The operative time was 107 ± 29 min, and there were no conversions to open surgery. Intraoperative methylene blue test detected leakage in 28 cases (3.93%). Postoperative contrast study (gastrografin) was negative for leakage in all cases. Computed tomography (CT) scan with oral contrast study detected leakage in 1.4% (ten cases); none of these cases were detected by regular contrast study. Our study showed that intraoperative methylene blue test for leakage is a very sensitive and effective method for detecting leakage during sleeve gastrectomy and should be done routinely in all cases. Routine postoperative contrast study is not needed to detect leakage unless clinically indicated in selected cases, and in such cases contrast-enhanced CT scans are the modality of choice.

  4. Simulation and experimental research of heat leakage of cryogenic transfer lines

    NASA Astrophysics Data System (ADS)

    Deng, B. C.; Xie, X. J.; Pan, W.; Jiang, R. X.; Li, J.; Yang, S. Q.; Li, Q.

    2017-12-01

    The heat leakage of cryogenic transfer lines directly influences the performance of large-scale helium refrigerator. In this paper, a thermal model of cryogenic transfer line considering numerical simulation of support coupled with MLI was established. To validate the model, test platform of cryogenic transfer lines with the merits of disassembly outer pipe and changeable easily multi-layer insulation has been built. The experimental results of heat leakage through overall length of cryogenic transfer lines, support and multi-layer insulation were obtained. The heat leakages of multi-layer insulation, a support and the overall leakage are 1.02 W/m, 0.44 W and 1.46 W/m from experimental data, respectively. The difference of heat leakage of MLI between experiment and simulation were less than 5%. The temperature distribution of support and MLI obtained in presented model in good agreement with experimental data. It is expected to reduce the overall heat leakage of cryogenic transfer lines further by optimizing structure of support based on the above thermal model and test platform in this paper.

  5. 40 CFR Appendix E to Subpart B of... - The Standard for Automotive Refrigerant Recycling Equipment Intended for Use With Both CFC-12 and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... liquid phase only. 4.2Seat Leakage Test 4.2.1 Valves, including electrically operated solenoid valves, that are used to isolate CFC-12 and HFC-134a refrigerant circuits, shall have a seat leakage rate not... Leakage Test shall be performed at 1.5 times this pressure at an ambient of 24 °C. 4.3Interlocks 4.3...

  6. X-connectors for tubing - Feasibility study

    NASA Technical Reports Server (NTRS)

    Bragg, K.; Fuhrmann, H. W.

    1970-01-01

    Connector tests, including 70 deg F leakage and vibration, proof pressure, burst pressure, tensility, thermal shock, high and low temperature leakage, and simultaneous high temperature vibration and leakage, prove feasibility of lightweight 0.5-in. X-connectors for 4500-lb/sq in. service pressures.

  7. Research on airborne infrared leakage detection of natural gas pipeline

    NASA Astrophysics Data System (ADS)

    Tan, Dongjie; Xu, Bin; Xu, Xu; Wang, Hongchao; Yu, Dongliang; Tian, Shengjie

    2011-12-01

    An airborne laser remote sensing technology is proposed to detect natural gas pipeline leakage in helicopter which carrying a detector, and the detector can detect a high spatial resolution of trace of methane on the ground. The principle of the airborne laser remote sensing system is based on tunable diode laser absorption spectroscopy (TDLAS). The system consists of an optical unit containing the laser, camera, helicopter mount, electronic unit with DGPS antenna, a notebook computer and a pilot monitor. And the system is mounted on a helicopter. The principle and the architecture of the airborne laser remote sensing system are presented. Field test experiments are carried out on West-East Natural Gas Pipeline of China, and the results show that airborne detection method is suitable for detecting gas leak of pipeline on plain, desert, hills but unfit for the area with large altitude diversification.

  8. Assessment of pediatric Malone antegrade continence enema (MACE) complications: Effects of variations in technique.

    PubMed

    Saikaly, Sami K; Rich, Mark A; Swana, Hubert S

    2016-08-01

    The Malone antegrade continence enema (MACE) procedure is performed for patients with fecal incontinence and constipation who do not respond to medical therapy. The MACE procedure provides antegrade catheter access to the right colon and allows administration of enemas to help evacuate the bowel regularly. The objective of this study was to identify risk factors for surgical complications in children who undergo the MACE procedure. Records from 97 pediatric patients who underwent MACE procedure were reviewed retrospectively. Data collected included age, sex, weight (obese/not obese), stomal location, presence of a permanent button/catheter in the stoma, open vs. laparoscopic surgery, and etiology of fecal incontinence/constipation. The complications reviewed included stomal stenosis, leakage, and stomal site infection. The relationships between the independent variables and complications were assessed using chi-square tests and Fisher's exact test. Statistical significance was set at p < 0.05. Overall, 66 (68%) patients had at least one complication. Twenty-three (23.7%) patients developed stomal stenosis, and 27 (27.8%) patients had significant stomal leakage. Insertion of a stomal button/catheter device was associated with an increased risk of developing stomal leakage and stomal infection. The presence of a stomal button/catheter was also associated with a decreased risk of stomal stenosis (Figure). The non-intubated, imbricated sub-population, preteen patients (<12 years old) experienced more stomal leakage than teenage patients. In this subgroup, patients with umbilical stomas also experienced more leakage than patients with right lower quadrant (RLQ) stomas. The prevalence rates of stomal complications in our study were consistent with previously reported series. In our study, however, stomal leakage had a higher prevalence in comparison with stomal stenosis. This seems to be related to the heterogeneity of the study group, which contained two variants of the MACE procedure; non-imbricated, intubated MACE and imbricated, non-intubated MACE. The use of stomal buttons in conjunction with MACE has previously been reported without changes in complication rates. We found the use of stomal buttons/catheters to be associated with changes in the prevalence of stomal complications. Stomal complications are common in the MACE procedure. The use of a permanent stomal button/catheter is associated with changes in the rates of stomal complications. While many find an umbilical stomal site is more cosmetically appealing, there is an increased risk of leakage with imbricated, non-intubated stomas. In the non-intubated, imbricated sub-population, the MACE procedure results in a higher risk of stomal leakage in preteen patients in comparison with teenage patients. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. Detection of gas leakage

    DOEpatents

    Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM

    2012-06-19

    A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  10. Detection of gas leakage

    DOEpatents

    Thornberg, Steven M; Brown, Jason

    2015-02-17

    A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  11. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    NASA Astrophysics Data System (ADS)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  12. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    NASA Technical Reports Server (NTRS)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  13. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2007-01-01

    Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.

  14. Behavior of a nuclear steel containment equipment hatch at large strain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanous, F.; Greimann, L.

    1988-05-01

    During a severe accident, buckling of a steel containment hatch door, large deformation and ovaling of the hatch sleeve are potential causes of mismatch at the sealing surface which can result in a leakage path. A three-dimensional nonlinear finite element analysis of a typical steel containment/sleeve/hatch assembly that includes containment stiffeners, pretensioned swing bolts, and hatch door geometric imperfection is presented. The analysis was carried out to the nonlinear range up to large strains. The results indicated that the buckling load occurs at pressure, far above that which causes gross yielding of the shell plate. Although buckling of the hatchmore » door increased the relative motions of the hatch sleeve and the hatch door, the motions remained sufficiently small to prevent leakage.« less

  15. Pulsed magnetic flux leakage method for hairline crack detection and characterization

    NASA Astrophysics Data System (ADS)

    Okolo, Chukwunonso K.; Meydan, Turgut

    2018-04-01

    The Magnetic Flux leakage (MFL) method is a well-established branch of electromagnetic Non-Destructive Testing (NDT), extensively used for evaluating defects both on the surface and far-surface of pipeline structures. However the conventional techniques are not capable of estimating their approximate size, location and orientation, hence an additional transducer is required to provide the extra information needed. This research is aimed at solving the inevitable problem of granular bond separation which occurs during manufacturing, leaving pipeline structures with miniature cracks. It reports on a quantitative approach based on the Pulsed Magnetic Flux Leakage (PMFL) method, for the detection and characterization of the signals produced by tangentially oriented rectangular surface and far-surface hairline cracks. This was achieved through visualization and 3D imaging of the leakage field. The investigation compared finite element numerical simulation with experimental data. Experiments were carried out using a 10mm thick low carbon steel plate containing artificial hairline cracks with various depth sizes, and different features were extracted from the transient signal. The influence of sensor lift-off and pulse width variation on the magnetic field distribution which affects the detection capability of various hairline cracks located at different depths in the specimen is explored. The findings show that the proposed technique can be used to classify both surface and far-surface hairline cracks and can form the basis for an enhanced hairline crack detection and characterization for pipeline health monitoring.

  16. Using electrolyte leakage tests to determine lifting windows and detect tissue damage

    Treesearch

    Richard W. Tinus

    2002-01-01

    Physiological testing is rapidly coming into use as a means to determine the condition of nursery stock and predict how it will respond to treatment or use. One such test, the electrolyte leakage test, can be used to measure cold hardiness and detect tissue damage. The principle of this test is that when cell membranes are damaged, electrolytes leak out into the water...

  17. Comparison of Radicular Peroxide Leakage from four Commonly used Bleaching agents following Intracoronal Bleaching in Endodontically treated teeth - An In Vitro Study.

    PubMed

    Madhu, Ks; Hegde, Swaroop; Mathew, Sylvia; Lata, DA; Bhandi, Shilpa H; N, Shruthi

    2013-08-01

    Non vital bleaching is simple, conservative procedure for esthetic correction of discolored endodontically treated teeth. The aim of this study was to determine and compare the amount of peroxide leakage from four different bleaching agents i.e superoxol, sodium perborate, combination of superoxol & sodium perborate and carbamide peroxide during intracoronal bleaching, as the safe and effective bleaching is the need of the hour. 50 extracted maxillary centrals were selected for the study. Following standardized protocol access, cleaning and shaping by step back technique and obturation was done using guttapercha and AH plus sealer. Access was sealed with Cavit G and outer root surface was coated with wax and nail varnish. The teeth were separated into crown and root and the root portion was placed in plastic tube containing distilled water for 7days.After incubation, 3mm of gutta-percha was removed below CEJ and 2mm glass ionomer cement base was placed. Grouped into five categories based on the bleaching agent placed in pulp chamber as -group1 (control)-distilled water, group 2-sodium perborate with distilled water , group 3- 30% hydrogen peroxide ,group 4-mixture of sodium perborate and 30% hydrogen peroxide and group 5-10% carbamide peroxide gel. Peroxide leakage was measured after 24hrs using ferrothiocyanate method and optical density using spectrophotometer. Statistical analysis of the data was conducted using ANOVA and multiple comparisons within the groups was done using BONFERRONI method (Post-Hoc tests). The results showed highest peroxide penetration from 30% hydrogen peroxide followed by mixture of sodium perborate with 30% hydrogen peroxide, mixture of sodium perborate with distilled water and least penetration from 10% carbamide peroxide gel. The results were statistically significant. Radicular peroxide leakage in 10% carbamide peroxide was significantly lower than the other tested bleaching agents making it a very safe alternative for intracoronal bleaching. How to cite this article: Madhu KS, Hegde S, Mathew S, Lata DA, Bhandi SH, Shruthi N. Comparison of Radicular Peroxide Leakage from four Commonly used Bleaching agents following Intracoronal Bleaching in Endodontically treated teeth - An In Vitro Study. J Int Oral Health 2013; 5(4):49-55.

  18. Improved Steam Turbine Leakage Control with a Brush Seal Design

    NASA Astrophysics Data System (ADS)

    Turnquist, Norman; Chupp, Raymond E.; Pastrana, Ryan; Wolfe, Chris; Burnett, Mark

    2002-10-01

    This paper presents an improved steam turbine leakage control system with a brush seal design. The contents include: 1) Typical Design Characteristics; 2) Typical Brush Seal Locations; 3) Reduced Leakage Rates; 4) Performance Benefits; 5) System Considerations; 6) Rotor Dynamics; 7) Laboratory Tests and 8) Field Experience.

  19. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    DOT National Transportation Integrated Search

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  20. 76 FR 11288 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-01

    ... Guide, DG-7008, ``Leakage Tests on Packages for Shipment of Radioactive Materials.'' FOR FURTHER... regulatory guide (DG), entitled, ``Leakage Tests on Packages for Shipment of Radioactive Materials'' is... Radioactive and Nonnuclear Hazardous Materials, N14, Subcommittee of the American National Standards Institute...

  1. Chemical colostomy irrigation with glyceryl trinitrate solution.

    PubMed

    O'Bichere, A; Bossom, C; Gangoli, S; Green, C; Phillips, R K

    2001-09-01

    Colostomy irrigation may improve patient quality of life, but is time consuming. This study tests the hypothesis that irrigation with glyceryl trinitrate solution, by inducing gastrointestinal smooth muscle relaxation, may accelerate expulsion of stool by passive emptying, thereby reducing irrigation time. Fifteen colostomy irrigators(with more than 3 years' experience) performed washout with tap water compared with water containing 0.025 mg/kg glyceryl trinitrate. Fluid inflow time, total washout time, and hemodynamic changes occurring during glyceryl trinitrate irrigation were documented by an independent observer. Subjects recorded episodes of fecal leakage and overall satisfaction on a visual analog scale. Cramps, headaches, and whether or not a stoma bag was used were expressed as a percentage of number of irrigations. Comparison of fluid inflow time, total washout time, leakage, and satisfaction was by Wilcoxon's signed-rank test and headaches, cramps, and stoma bag use was by McNemar's test. Pulse rate (paired t-test), systolic and diastolic blood pressures (Wilcoxon's test) at 20 and 240 minutes after washout with glyceryl trinitrate solution were compared with baseline. Fifteen patients (9 female), with a mean age of 53 (31-73) years, provided 30 sessions (15 with water and 15 with glyceryl trinitrate). Medians (interquartile ranges) for water vs. glyceryl trinitrate were fluid inflow time 7 (4-10) vs. 4, (3-5; P = 0.001); total washout time 40 (30-55) vs. 21, (15-24; P < 0.001); leakage 0 (0-1) vs. 0, (0-0; P = 0.02), satisfaction 10 (8-10) vs. 10 (9-10; P = 0.31). The number (percentage) of stoma bags, cramps, and headaches with water vs. glyceryl trinitrate were 7 (47 percent) vs. 7 (47 percent), P = 1; 1 (7 percent) vs. 14 (93 percent), P < 0.001; and 0(0 percent) vs. 14 (93 percent), P < 0.001, respectively. Changes in pulse (increase) and systolic and diastolic blood pressures (decrease) from baseline were maximal at 20 minutes (P < 0.001, P = 0.001, and P = 0.002, respectively) and had returned to baseline by 240 minutes (P = 0.52, P = 0.08, and P = 1, respectively). Glyceryl trinitrate solution significantly reduces colostomy irrigation time compared with the generally recommended tap water. Patients suffer fewer leakages and are highly satisfied, but side effects are potential drawbacks. Other colonoplegic agent solutions should now be evaluated.

  2. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2006-01-01

    Secondary seal leakage in jet engine applications results in power losses to the engine cycle. Likewise, seal power loss in jet engines not only result in efficiency loss but also increase the heat input into the engine resulting in reduced component lives. Experimental work on labyrinth and annular seals was performed at NASA Glenn Research Center to quantify seal leakage and power loss at various temperatures, seal pressure differentials, and surface speeds. Data from annular and labyrinth seals are compared with previous brush and finger seal test results. Data are also compared to literature. Annular and labyrinth seal leakage rates are 2 to 3 times greater than brush and finger seal rates. Seal leakage decreases with increasing speed but increases with increasing test temperature due to thermal expansion mismatch. Also seal power loss increases with surface speed, seal pressure differential, mass flow rate, and radial clearance. Annular and labyrinth seal power losses were higher than those of brush or finger seal data. The brush seal power loss was 15 to 30 percent lower than annular and labyrinth seal power loss.

  3. Leakage of fluid around endotracheal tube cuffs: a cadaver study

    PubMed Central

    Lucius, Ralph; Ewald, Kristian

    2013-01-01

    Background The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Methods Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. Results The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. Conclusions The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required. PMID:24363847

  4. Intraoperatively Testing the Anastomotic Integrity of Esophagojejunostomy Using Methylene Blue.

    PubMed

    Celik, S; Almalı, N; Aras, A; Yılmaz, Ö; Kızıltan, R

    2017-03-01

    Intraoperative testing of gastrointestinal anastomosis effectively ensures anastomotic integrity. This study investigated whether the routine use of methylene blue intraoperatively identified leaks to reduce the postoperative proportion of clinical leaks. This study retrospectively analyzed consecutive total gastrectomies performed from January 2007 to December 2014 in a university hospital setting by a general surgical group that exclusively used the methylene blue test. All surgeries were performed for gastric or junctional cancers (n = 198). All reconstructions (Roux-en Y esophagojejunostomy) were performed using a stapler. The methylene blue test was used in 108 cases (group 1) via a nasojejunal tube. No test was performed for the other 90 cases (group 2). Intraoperative leakage rate, postoperative clinical leakage rate, length of hospitalization, and mortality rate were the outcome measures. The intraoperative leakage rate was 7.4% in group 1. The postoperative clinical leakage rate was 8.6%. The postoperative clinical leakage rate was 3.7% in group 1 and 14.4% in group 2 (p = 0.007). There were no postoperative clinical leaks when an intraoperative leak led to concomitant intraoperative repair. The median length of hospital stay was 6 days in group 1 and 8 days in group 2 (p < 0.001). One death occurred in each group. No test-related complications were observed. The methylene blue test for esophagojejunostomy is a safe and reliable method for the assessment of anastomosis integrity, especially in cases with difficult esophagojejunostomic construction.

  5. Automated Detection of Leakage in Fluorescein Angiography Images with Application to Malarial Retinopathy

    PubMed Central

    Zhao, Yitian; J. C. MacCormick, Ian; G. Parry, David; Leach, Sophie; A. V. Beare, Nicholas; P. Harding, Simon; Zheng, Yalin

    2015-01-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage. PMID:26030010

  6. Automated detection of leakage in fluorescein angiography images with application to malarial retinopathy.

    PubMed

    Zhao, Yitian; MacCormick, Ian J C; Parry, David G; Leach, Sophie; Beare, Nicholas A V; Harding, Simon P; Zheng, Yalin

    2015-06-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage.

  7. APPLICATION OF A GEOGRAPHIC INFORMATION SYSTEM FOR A CONTAINMENT SYSTEM LEAK DETECTION

    EPA Science Inventory

    The use of physical and hydraulic containment systems for the isolation of contaminated ground water associated with hazardous waste sites has increased during the last decade. Existing methodologies for monitoring and evaluating leakage from hazardous waste containment systems ...

  8. [Bile leakage after liver resection: A retrospective cohort study].

    PubMed

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (p<0.001), major hepatic resection (p=0.001), operative time (p<0.001), high intraoperative blood loss (p=0.02), construction of HJA (p=0.005), portal venous embolization/two-stage surgery (p=0.009) and ASA score (p=0.02). Bile leakage significantly prolonged hospitalization time (p<0.001). In the group of patients with bile leakage the perioperative mortality was 23 times higher (p<0.001) than in the group with no leakage. Bile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve the perioperative management and techniques to prevent such serious complications. Multidisciplinary approach is essential in the treatment.

  9. Integrated Framework for Assessing Impacts of CO₂ Leakage on Groundwater Quality and Monitoring-Network Efficiency: Case Study at a CO₂ Enhanced Oil Recovery Site.

    PubMed

    Yang, Changbing; Hovorka, Susan D; Treviño, Ramón H; Delgado-Alonso, Jesus

    2015-07-21

    This study presents a combined use of site characterization, laboratory experiments, single-well push-pull tests (PPTs), and reactive transport modeling to assess potential impacts of CO2 leakage on groundwater quality and leakage-detection ability of a groundwater monitoring network (GMN) in a potable aquifer at a CO2 enhanced oil recovery (CO2 EOR) site. Site characterization indicates that failures of plugged and abandoned wells are possible CO2 leakage pathways. Groundwater chemistry in the shallow aquifer is dominated mainly by silicate mineral weathering, and no CO2 leakage signals have been detected in the shallow aquifer. Results of the laboratory experiments and the field test show no obvious damage to groundwater chemistry should CO2 leakage occur and further were confirmed with a regional-scale reactive transport model (RSRTM) that was built upon the batch experiments and validated with the single-well PPT. Results of the RSRTM indicate that dissolved CO2 as an indicator for CO2 leakage detection works better than dissolved inorganic carbon, pH, and alkalinity at the CO2 EOR site. The detection ability of a GMN was assessed with monitoring efficiency, depending on various factors, including the natural hydraulic gradient, the leakage rate, the number of monitoring wells, the aquifer heterogeneity, and the time for a CO2 plume traveling to the monitoring well.

  10. Measured airtightness of an installed skylight

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, C.Y.; Magee, R.J.; Poirier, G.F.

    2000-07-01

    An art gallery building had problems with moisture. Inspections using thermographic techniques suggested that air leakage through the skylights could be the main cause of the problem. The air leakage rate of an installed metal frame skylight, 26 m long x 8.5 m wide, was measured, using the balanced fan depressurization method. Also, fan depressurization tests were performed on the glazing/upstand interface on the south side of the skylight. The air leakage rates were measured through the full interface and on the west and east halves separately. The methods used for field testing of such components and the test resultsmore » are discussed.« less

  11. Spatial and Temporal Monitoring Resolutions for CO2 Leakage Detection at Carbon Storage Sites

    NASA Astrophysics Data System (ADS)

    Yang, Y. M.; Dilmore, R. M.; Daley, T. M.; Carroll, S.; Mansoor, K.; Gasperikova, E.; Harbert, W.; Wang, Z.; Bromhal, G. S.; Small, M.

    2016-12-01

    Different leakage monitoring techniques offer different strengths in detection sensitivity, coverage, feedback time, cost, and technology availability, such that they may complement each other when applied together. This research focuses on quantifying the spatial coverage and temporal resolution of detection response for several geophysical remote monitoring and direct groundwater monitoring techniques for an optimal monitoring plan for CO2 leakage detection. Various monitoring techniques with different monitoring depths are selected: 3D time-lapse seismic survey, wellbore pressure, groundwater chemistry and soil gas. The spatial resolution in terms of leakage detectability is quantified through the effective detection distance between two adjacent monitors, given the magnitude of leakage and specified detection probability. The effective detection distances are obtained either from leakage simulations with various monitoring densities or from information garnered from field test data. These spatial leakage detection resolutions are affected by physically feasible monitoring design and detection limits. Similarly, the temporal resolution, in terms of leakage detectability, is quantified through the effective time to positive detection of a given size of leak and a specified detection probability, again obtained either from representative leakage simulations with various monitoring densities or from field test data. The effective time to positive detection is also affected by operational feedback time (associated with sampling, sample analysis and data interpretation), with values obtained mainly through expert interviews and literature review. In additional to the spatial and temporal resolutions of these monitoring techniques, the impact of CO2 plume migration speed and leakage detection sensitivity of each monitoring technique are also discussed with consideration of how much monitoring is necessary for effective leakage detection and how these monitoring techniques can be better combined in a time-space framework. The results of the spatial and temporal leakage detection resolutions for several geophysical monitoring techniques and groundwater monitoring are summarized to inform future monitoring designs at carbon storage sites.

  12. Assessing the accuracy of TDR-based water leak detection system

    NASA Astrophysics Data System (ADS)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  13. Investigating Low Temperature Properties of Rubber Seals - 13020

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaunich, M.; Wolff, D.; Stark, W.

    To achieve the required tightness levels of containers for low and intermediate level radioactive wastes rubbers are widely applied as main sealing materials. The save encapsulation of the radioactive container contents has to be guaranteed according to legislation and appropriate guidelines for long storage periods as well as down to temperatures of -40 deg. C during transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is of high importance. It is known that the material properties of rubbers are strongly influenced by temperature. At low temperatures this is caused by the rubber-glass transition (abbr. glassmore » transition). During continuous cooling the material changes from rubber-like entropy-elastic to stiff energy-elastic behaviour, that allows nearly no strain or retraction. Therefore, rubbers are normally used above their glass transition but the minimum working temperature limit is not defined precisely, what can cause problems during application. The temperature range where full functionality is possible is strongly dependent on the application conditions and the material. For this investigation mainly ethylene propylene diene (EPDM) and fluorocarbon rubbers (FKM) were selected as they are often used for radioactive waste containers. Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) are typically used for the determination of the temperature range of the glass transition process. The standardized compression set measurement according to ISO 815 is common for investigation of rubber sealing materials as the test simulates the seal behaviour after release. To reduce the test time of the standard tests a faster technique giving the same information was developed. Additionally, the breakdown temperature of the sealing function of complete O-ring seals is measured in a component test setup to compare it with the results of the other tests. The experimental setup is capable of measuring the leakage rate at low temperatures by the pressure rise method. A model was developed that allows calculating the minimum working temperature limit of a seal by combining the results of the applied methods. (authors)« less

  14. Improved Seals for High Temperature Airframe Applications

    NASA Technical Reports Server (NTRS)

    DeMange, Jeffrey J.; Dunlap, Patrick H.; Steinetz, Bruce M.

    2006-01-01

    Current thermal barrier seals, such as those used on the Space Shuttle, are insufficient to fully meet the demands of future hypersonic vehicles and reentry spacecraft. Previous investigations have demonstrated limited usage temperatures, as evidenced by a decreased ability to maintain sealing effectiveness at high temperatures (i.e., inadequate resiliency). In order to improve resiliency at elevated temperatures, Rene 41 (Allvac) was substituted for Inconel X-750 (Special Metals Corp.) as the spring tube material in the existing seal design. A seal construction incorporating the Rene 41 spring tube was fabricated and tested against the baseline Inconel X-750 spring tube seal. Although resiliency improvements were not as dramatic as in previous tests with the spring tubes alone, seals incorporating the Rene 41 spring tube exhibited an average 20 percent resiliency enhancement up to 1750 F when compared to seals containing the Inconel spring tube. In addition, the seals with the Rene 41 spring tubes showed less reduction in resiliency as temperatures increased above 1200 F. Results also indicated the Saffil (Saffil Ltd.) insulation in the core of the seal contributed more to resiliency than previously thought. Leakage data did not demonstrate an improvement with the seal containing the Rene 41 spring tube. However, based upon resiliency results, one could reasonably expect the Rene 41 version of the seal to track gap openings over a wider range. Therefore it would exhibit lower leakage than the Inconel X-750 version as the seal gap opens during a typical mission.

  15. 9 CFR 318.301 - Containers and closures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 318.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... examinations for rigid containers (cans)—(1) Visual examinations. A closure technician shall visually examine... container shall be examined for product leakage or obvious defects. A visual examination shall be performed...

  16. A novel method to determine air leakage in heat pump clothes dryers

    DOE PAGES

    Bansal, Pradeep; Mohabir, Amar; Miller, William

    2016-01-06

    A heat pump clothes dryer offers the potential to save a significant amount of energy as compared with conventional vented electric dryers. Although heat pump clothes dryers (HPCD) offer higher energy efficiency; it has been observed that they are prone to air leakages, which inhibits the HPCD's gain in efficiency. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The basis of this method is the American Society of Testing and Materials (ASTM) standard E779 10, which is used to determine air leakage areamore » in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. Easily accessible leakage points were quantified: the front and back crease (in the dryer drum), the leakage in the dryer duct, the air filter, and the remaining leakage in the drum. The procedure allows investigators to determine major components contributing to leakage in HPCDs, thus improving component design features that result in more efficient HPCD systems.« less

  17. A novel method to determine air leakage in heat pump clothes dryers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bansal, Pradeep; Mohabir, Amar; Miller, William

    A heat pump clothes dryer offers the potential to save a significant amount of energy as compared with conventional vented electric dryers. Although heat pump clothes dryers (HPCD) offer higher energy efficiency; it has been observed that they are prone to air leakages, which inhibits the HPCD's gain in efficiency. This study serves to develop a novel method of quantifying leakage, and to determine specific leakage locations in the dryer drum and air circulation system. The basis of this method is the American Society of Testing and Materials (ASTM) standard E779 10, which is used to determine air leakage areamore » in a household ventilation system through fan pressurization. This ASTM method is adapted to the dryer system, and the leakage area is determined by an analysis of the leakage volumetric flow - pressure relationship. Easily accessible leakage points were quantified: the front and back crease (in the dryer drum), the leakage in the dryer duct, the air filter, and the remaining leakage in the drum. The procedure allows investigators to determine major components contributing to leakage in HPCDs, thus improving component design features that result in more efficient HPCD systems.« less

  18. Inhibition of Enveloped Viruses Infectivity by Curcumin

    PubMed Central

    Wen, Hsiao-Wei; Ou, Jun-Lin; Chiou, Shyan-Song; Chen, Jo-Mei; Wong, Min-Liang; Hsu, Wei-Li

    2013-01-01

    Curcumin, a natural compound and ingredient in curry, has antiinflammatory, antioxidant, and anticarcinogenic properties. Previously, we reported that curcumin abrogated influenza virus infectivity by inhibiting hemagglutination (HA) activity. This study demonstrates a novel mechanism by which curcumin inhibits the infectivity of enveloped viruses. In all analyzed enveloped viruses, including the influenza virus, curcumin inhibited plaque formation. In contrast, the nonenveloped enterovirus 71 remained unaffected by curcumin treatment. We evaluated the effects of curcumin on the membrane structure using fluorescent dye (sulforhodamine B; SRB)-containing liposomes that mimic the viral envelope. Curcumin treatment induced the leakage of SRB from these liposomes and the addition of the influenza virus reduced the leakage, indicating that curcumin disrupts the integrity of the membranes of viral envelopes and of liposomes. When testing liposomes of various diameters, we detected higher levels of SRB leakage from the smaller-sized liposomes than from the larger liposomes. Interestingly, the curcumin concentration required to reduce plaque formation was lower for the influenza virus (approximately 100 nm in diameter) than for the pseudorabies virus (approximately 180 nm) and the vaccinia virus (roughly 335 × 200 × 200 nm). These data provide insights on the molecular antiviral mechanisms of curcumin and its potential use as an antiviral agent for enveloped viruses. PMID:23658730

  19. Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Degado, Irebert R.

    2008-01-01

    Low leakage, non-contacting finger seals have potential to reduce gas turbine engine specific fuel consumption by 2 to 3 percent and to reduce direct operating costs by increasing the time between engine overhauls. A non-contacting finger seal with concentric lift-pads operating adjacent to a test rotor with herringbone grooves was statically tested at 300, 533, and 700 K inlet air temperatures at pressure differentials up to 576 kPa. Leakage flow factors were approximately 70 percent less than state-of-the-art labyrinth seals. Leakage rates are compared to first order predictions. Initial spin tests at 5000 rpm, 300 K inlet air temperature and pressure differentials to 241 kPa produced no measurable wear.

  20. Pressure Control System Design for a Closed Crop Growth Chamber

    NASA Technical Reports Server (NTRS)

    Tsai, K.; Blackwell, C.; Harper, Lynn D. (Technical Monitor)

    1994-01-01

    The Controlled Ecological Life Support System (CELSS) is an area of active research at NASA. CELSS is a plant-based bioregenerative life support system for long term manned space flights where resupply is costly or impractical. The plants in a CELSS will function to convert the carbon dioxide (exhaled by the crew) into oxygen, purify non-potable water into potable quality water, and provide food for the crew. Prior to implementing a CELSS life support system, one must have knowledge on growing plants in a closed chamber under low gravity. This information will come from research to be conducted on the CELSS Test Facility that will operate on the Space Station Freedom. Currently a ground-based CELSS Test Facility is being built at NASA Ames Research Center. It is called the EDU (Engineering Development Unit). This system will allow researchers to identify issues that may cause difficulties in the development of the CELSS Test Facility and aid in the development of new needed technologies. The EDU consists of a 1 m2 crop growth chamber that is surrounded by a containment enclosure. The containment enclosure isolates the system so there is very little mass and thermal exchange with the ambient. The leakage rate is on the order of 1 % of the enclosure's volume per day (with 0.2S psi pressure difference). The thermal leakage is less than 0.5% of the electrical power supplied to the system per degree Celsius difference from the surrounding. The pressure in the containment enclosure is regulated at 62.5 Pa below the ambient by an active controller. The goal is to maintain this set point for a variety of conditions, such as a range of operating temperatures, heat load variations that occur when the lights are turned on and off, and fluctuations in ambient pressure. In addition certain transition tracking performance is required. This paper illustrates the application of some advanced systems control methods to the task of synthesizing the EDU's pressure control system.

  1. Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.

  2. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test; minimum requirements. 84.1150 Section 84.1150 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  3. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test; minimum requirements. 84.1150 Section 84.1150 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  4. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Exhalation valve leakage test; minimum requirements. 84.1150 Section 84.1150 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  5. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Exhalation valve leakage test; minimum requirements. 84.1150 Section 84.1150 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  6. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Exhalation valve leakage test; minimum requirements. 84.1150 Section 84.1150 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  7. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84...

  8. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84...

  9. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84...

  10. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84...

  11. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84...

  12. Endothelial gaps and adherent leukocytes in allergen-induced early- and late-phase plasma leakage in rat airways.

    PubMed Central

    Baluk, P.; Bolton, P.; Hirata, A.; Thurston, G.; McDonald, D. M.

    1998-01-01

    Exposure of sensitized individuals to antigen can induce allergic responses in the respiratory tract, manifested by early and late phases of vasodilatation, plasma leakage, leukocyte influx, and bronchoconstriction. Similar responses can occur in the skin, eye, and gastrointestinal tract. The early-phase response involves mast cell mediators and the late-phase response is leukocyte dependent, but the mechanism of leakage is not understood. We sought to identify the leaky blood vessels, to determine whether these vessels contained endothelial gaps, and to analyze the relationship of the gaps to adherent leukocytes, using biotinylated lectins or silver nitrate to stain the cells in situ and Monastral blue as a tracer to quantify plasma leakage. Most of the leakage occurred in postcapillary venules (< 40-microns diameter), whereas most of the leukocyte migration (predominantly neutrophils) occurred in collecting venules. Capillaries and arterioles did not leak. Endothelial gaps were found in the leaky venules, both by silver nitrate staining and by scanning electron microscopy, and 94% of the gaps were distinct from sites of leukocyte adhesion or migration. We conclude that endothelial gaps contribute to both early and late phases of plasma leakage induced by antigen, but most leakage occurs upstream to sites of leukocyte adhesion. Images Figure 3 Figure 5 Figure 6 Figure 7 PMID:9626051

  13. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    NASA Astrophysics Data System (ADS)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  14. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which ismore » already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.« less

  15. Do sterols reduce proton and sodium leaks through lipid bilayers?

    PubMed

    Haines, T H

    2001-07-01

    Proton and/or sodium electrochemical gradients are critical to energy handling at the plasma membranes of all living cells. Sodium gradients are used for animal plasma membranes, all other living organisms use proton gradients. These chemical and electrical gradients are either created by a cation pumping ATPase or are created by photons or redox, used to make ATP. It has been established that both hydrogen and sodium ions leak through lipid bilayers at approximately the same rate at the concentration they occur in living organisms. Although the gradients are achieved by pumping the cations out of the cell, the plasma membrane potential enhances the leakage rate of these cations into the cell because of the orientation of the potential. This review proposes that cells use certain lipids to inhibit cation leakage through the membrane bilayers. It assumes that Na(+) leaks through the bilayer by a defect mechanism. For Na(+) leakage in animal plasma membranes, the evidence suggests that cholesterol is a key inhibitor of Na(+) leakage. Here I put forth a novel mechanism for proton leakage through lipid bilayers. The mechanism assumes water forms protonated and deprotonated clusters in the lipid bilayer. The model suggests how two features of lipid structures may inhibit H(+) leakage. One feature is the fused ring structure of sterols, hopanoids and tetrahymenol which extrude water and therefore clusters from the bilayer. The second feature is lipid structures that crowd the center of the bilayer with hydrocarbon. This can be accomplished either by separating the two monolayers with hydrocarbons such as isoprenes or isopranes in the bilayer's cleavage plane or by branching the lipid chains in the center of the bilayers with hydrocarbon. The natural distribution of lipids that contain these features are examined. Data in the literature shows that plasma membranes exposed to extreme concentrations of cations are particularly rich in the lipids containing the predicted qualities. Prokaryote plasma membranes that reside in extreme acids (acidophiles) contain both hopanoids and iso/anteiso- terminal lipid branching. Plasma membranes that reside in extreme base (alkaliphiles) contain both squalene and iso/anteiso- lipids. The mole fraction of squalene in alkaliphile bilayers increases, as they are cultured at higher pH. In eukaryotes, cation leak inhibition is here attributed to sterols and certain isoprenes, dolichol for lysosomes and peroxysomes, ubiquinone for these in addition to mitochondrion, and plastoquinone for the chloroplast. Phytosterols differ from cholesterol because they contain methyl and ethyl branches on the side chain. The proposal provides a structure-function rationale for distinguishing the structures of the phytosterols as inhibitors of proton leaks from that of cholesterol which is proposed to inhibit leaks of Na(+). The most extensively studied of sterols, cholesterol, occurs only in animal cells where there is a sodium gradient across the plasma membrane. In mammals, nearly 100 proteins participate in cholesterol's biosynthetic and degradation pathway, its regulatory mechanisms and cell-delivery system. Although a fat, cholesterol yields no energy on degradation. Experiments have shown that it reduces Na(+) and K(+) leakage through lipid bilayers to approximately one third of bilayers that lack the sterol. If sterols significantly inhibit cation leakage through the lipids of the plasma membrane, then the general role of all sterols is to save metabolic ATP energy, which is the penalty for cation leaks into the cytosol. The regulation of cholesterol's appearance in the plasma membrane and the evolution of sterols is discussed in light of this proposed role.

  16. The effectiveness of four-cavity treatment systems in sealing amalgam restorations.

    PubMed

    Morrow, Leean A; Wilson, Nairn H F

    2002-01-01

    Amalgam does not bond to tooth tissue; therefore, restorations using such material are prone to leakage despite the deposition of corrosion products. This study evaluated the effectiveness of four cavity treatment systems placed in vivo in sealing restorations of amalgam. Four cavity treatment systems were investigated in this study: Cervitec, Gluma One Bond, Panavia 21 and Copaliner Dentin Varnish and Sealant. No cavity treatment was placed in an additional group to serve as a control. The teeth were extracted within 15 minutes of restoration placement. The specimens were thermocycled (5-55 +/- 2 degrees C, 500 cycles), immersed in a dye solution, sectioned and scored for leakage. Scanning electron microscopy also examined features of the tooth/restoration interfaces. There were statistically significant differences among the groups regarding leakage scores (p = 0.00). None of the materials tested consistently prevented leakage; however, use of Copaliner Dentin Varnish and Sealant resulted in less overall, occlusal and cervical microleakage than any other systems tested. Significantly more leakage was observed in relation to the cervical portions of the cavities (p = 0.00). No significant differences were identified between the leakage scores obtained for the buccal and palatal (lingual) cavities and the different tooth types (p = 0.52 and 0.83, respectively). A level of significance of 0.05 was selected in all cases. The benefits of the materials tested in this study need to be evaluated using robust, long-term clinical studies. Further work should continue to develop laboratory tests that predict the behavior and performance of cavity sealants in clinical service.

  17. The utility of 5-aminolevulinic acid-mediated photodynamic diagnosis in the detection of intraoperative bile leakage.

    PubMed

    Inoue, Yoshihiro; Imai, Yoshiro; Fujii, Kensuke; Hirokawa, Fumitoshi; Hayashi, Michihiro; Uchiyama, Kazuhisa

    2017-06-01

    The purpose of this retrospective study was to evaluate the utility of the new intraoperative bile leakage test as a preventive measure of postoperative bile leakage. 737 patients were retrospectively analyzed with respect to the management of intra- and post-operative bile leakage. Nine (8.3%) of 109 patients evaluated using conventional white light fluorescent imaging were recognized as having intra-operative bile leakage. However, performance of 5-aminolevulinic acid (5-ALA)-mediated PDD detected bile leakage intraoperatively not only in these 9 patients, but also in an additional 6 patients, such that 'red fluorescence' at the cut surface of the liver, was visualized in a total of 15 patients. The postoperative courses of most patients were uneventful, and postoperative bile leakages occurred in only one (0.9%) patient. 5-ALA fluorescence imaging may be needed to prevent postoperative bile leakage in patients at high risk for this surgical complication after hepatic resection. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Detection of cerebrospinal fluid leakage by specific measurement of transferrin glycoforms.

    PubMed

    Kwon, Seok-Joon; Zhang, Fuming; Dordick, Jonathan S; Sonstein, William J; Linhardt, Robert J

    2015-10-01

    A simple and rapid detection of cerebrospinal fluid (CSF) leakage would benefit spine surgeons making critical postoperative decisions on patient care. We have assessed novel approaches to selectively determine CSF β2-transferrin (β2TF), an asialo-transferrin (aTF) biomarker, without interference from serum sialo-transferrin (sTF) in test samples. First, we performed mild periodate oxidation to selectively generate aldehyde groups in sTF for capture with magnetic hydrazide microparticles, and selective removal with a magnetic separator. Using this protocol sTF was selectively removed from mixtures of CSF and serum containing CSF aTF (β2TF) and serum sTF, respectively. Second, a two-step enzymatic method was developed with neuraminidase and galactose oxidase for generating aldehyde groups in sTF present in CSF and serum mixtures for magnetic hydrazide microparticle capture. After selectively removing sTF from mixtures of CSF and serum, ELISA could detect significant TF signal only in CSF, while the TF signal in serum was negligible. The new approach for selective removal of only sTF in test samples will be promising for the required intervention by a spine surgeon. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Hyperspectral Geobotanical Remote Sensing for Monitoring and Verifying CO 2 Containment Final Report CRADA No. TC-2036-02

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickles, W. L.; Ebrom, D. A.

    This collaborative effort was in support of the CO 2 Capture Project (CCP), to develop techniques that integrate overhead images of plant species, plant health, geological formations, soil types, aquatic, and human use spatial patterns for detection and discrimination of any CO 2 releases from underground storage formations. The goal of this work was to demonstrate advanced hyperspectral geobotanical remote sensing methods to assess potential leakage of CO 2 from underground storage. The timeframes and scales relevant to the long-term storage of CO 2 in the subsurface make remote sensing methods attractive. Moreover, it has been shown that individual fieldmore » measurements of gas composition are subject to variability on extremely small temporal and spatial scales. The ability to verify ultimate reservoir integrity and to place individual surface measurements into context will be crucial to successful long-term monitoring and verification activities. The desired results were to produce a defined and tested procedure that could be easily used for long-term monitoring of possible CO 2 leakage from underground CO 2 sequestration sites. This testing standard will be utilized on behalf of the oil industry.« less

  20. Transport analysis of measured neutron leakage spectra from spheres as tests of evaluated high energy cross sections

    NASA Technical Reports Server (NTRS)

    Bogart, D. D.; Shook, D. F.; Fieno, D.

    1973-01-01

    Integral tests of evaluated ENDF/B high-energy cross sections have been made by comparing measured and calculated neutron leakage flux spectra from spheres of various materials. An Am-Be (alpha,n) source was used to provide fast neutrons at the center of the test spheres of Be, CH2, Pb, Nb, Mo, Ta, and W. The absolute leakage flux spectra were measured in the energy range 0.5 to 12 MeV using a calibrated NE213 liquid scintillator neutron spectrometer. Absolute calculations of the spectra were made using version 3 ENDF/B cross sections and an S sub n discrete ordinates multigroup transport code. Generally excellent agreement was obtained for Be, CH2, Pb, and Mo, and good agreement was observed for Nb although discrepancies were observed for some energy ranges. Poor comparative results, obtained for Ta and W, are attributed to unsatisfactory nonelastic cross sections. The experimental sphere leakage flux spectra are tabulated and serve as possible benchmarks for these elements against which reevaluated cross sections may be tested.

  1. Vigorous exchange between the Indian and Atlantic oceans at the end of the past five glacial periods.

    PubMed

    Peeters, Frank J C; Acheson, Ruth; Brummer, Geert-Jan A; De Ruijter, Wilhelmus P M; Schneider, Ralph R; Ganssen, Gerald M; Ufkes, Els; Kroon, Dick

    2004-08-05

    The magnitude of heat and salt transfer between the Indian and Atlantic oceans through 'Agulhas leakage' is considered important for balancing the global thermohaline circulation. Increases or reductions of this leakage lead to strengthening or weakening of the Atlantic meridional overturning and associated variation of North Atlantic Deep Water formation. Here we show that modern Agulhas waters, which migrate into the south Atlantic Ocean in the form of an Agulhas ring, contain a characteristic assemblage of planktic foraminifera. We use this assemblage as a modern analogue to investigate the Agulhas leakage history over the past 550,000 years from a sediment record in the Cape basin. Our reconstruction indicates that Indian-Atlantic water exchange was highly variable: enhanced during present and past interglacials and largely reduced during glacial intervals. Coherent variability of Agulhas leakage with northern summer insolation suggests a teleconnection to the monsoon system. The onset of increased Agulhas leakage during late glacial conditions took place when glacial ice volume was maximal, suggesting a crucial role for Agulhas leakage in glacial terminations, timing of interhemispheric climate change and the resulting resumption of the Atlantic meridional overturning circulation.

  2. A Location Method Using Sensor Arrays for Continuous Gas Leakage in Integrally Stiffened Plates Based on the Acoustic Characteristics of the Stiffener

    PubMed Central

    Bian, Xu; Li, Yibo; Feng, Hao; Wang, Jiaqiang; Qi, Lei; Jin, Shijiu

    2015-01-01

    This paper proposes a continuous leakage location method based on the ultrasonic array sensor, which is specific to continuous gas leakage in a pressure container with an integral stiffener. This method collects the ultrasonic signals generated from the leakage hole through the piezoelectric ultrasonic sensor array, and analyzes the space-time correlation of every collected signal in the array. Meanwhile, it combines with the method of frequency compensation and superposition in time domain (SITD), based on the acoustic characteristics of the stiffener, to obtain a high-accuracy location result on the stiffener wall. According to the experimental results, the method successfully solves the orientation problem concerning continuous ultrasonic signals generated from leakage sources, and acquires high accuracy location information on the leakage source using a combination of multiple sets of orienting results. The mean value of location absolute error is 13.51 mm on the one-square-meter plate with an integral stiffener (4 mm width; 20 mm height; 197 mm spacing), and the maximum location absolute error is generally within a ±25 mm interval. PMID:26404316

  3. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, M.B.

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of themore » recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality, and addition of the basic cost of determining the initial leakage rate to the recommended expenditure level. Recommendations for the field test of the procedure include increasing the number of houses in the sample, more timely examination of metered data to detect anomalies, and the monitoring of indoor air temperature. Though not appropriate in a field test of a procedure, further investigation into the effects of air leakage rate reductions on heating loads needs to be performed.« less

  4. Development of helicopter transmission seals, task 2

    NASA Technical Reports Server (NTRS)

    Hayden, T. S.; Keller, C. H., Jr.

    1973-01-01

    High speed helicopter transmission seal concepts were designed, fabricated and tested. The concepts were a dual element split ring seal and a circumferential seal. The tests were performed in a rig using an actual input quill assembly. The test conditions were selected to simulate transmission operation and were 230 F oil temperature, and a sliding speed of 9400 ft/min. The split ring seal exhibited gross leakage and was considered unsatisfactory, while the circumferential seal leakage was less than 1 c.c./hour; this leakage is within acceptable limits. The circumferential seal wear was only to .0005 inches during a 100 hour run (40 starts and stops). During a 40 hour contamination test (mesh silica flour) the seal total wear was a maximum of .004 inches. This wear is considered acceptable.

  5. Evaluation of the user seal check on gross leakage detection of 3 different designs of N95 filtering facepiece respirators.

    PubMed

    Lam, Simon C; Lui, Andrew K F; Lee, Linda Y K; Lee, Joseph K L; Wong, K F; Lee, Cathy N Y

    2016-05-01

    The use of N95 respirators prevents spread of respiratory infectious agents, but leakage hampers its protection. Manufacturers recommend a user seal check to identify on-site gross leakage. However, no empirical evidence is provided. Therefore, this study aims to examine validity of a user seal check on gross leakage detection in commonly used types of N95 respirators. A convenience sample of 638 nursing students was recruited. On the wearing of 3 different designs of N95 respirators, namely 3M-1860s, 3M-1862, and Kimberly-Clark 46827, the standardized user seal check procedure was carried out to identify gross leakage. Repeated testing of leakage was followed by the use of a quantitative fit testing (QNFT) device in performing normal breathing and deep breathing exercises. Sensitivity, specificity, predictive values, and likelihood ratios were calculated accordingly. As indicated by QNFT, prevalence of actual gross leakage was 31.0%-39.2% with the 3M respirators and 65.4%-65.8% with the Kimberly-Clark respirator. Sensitivity and specificity of the user seal check for identifying actual gross leakage were approximately 27.7% and 75.5% for 3M-1860s, 22.1% and 80.5% for 3M-1862, and 26.9% and 80.2% for Kimberly-Clark 46827, respectively. Likelihood ratios were close to 1 (range, 0.89-1.51) for all types of respirators. The results did not support user seal checks in detecting any actual gross leakage in the donning of N95 respirators. However, such a check might alert health care workers that donning a tight-fitting respirator should be performed carefully. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Microbial Stimulation and Succession following a Test Well Injection Simulating CO₂ Leakage into a Shallow Newark Basin Aquifer

    PubMed Central

    O’Mullan, Gregory; Dueker, M. Elias; Clauson, Kale; Yang, Qiang; Umemoto, Kelsey; Zakharova, Natalia; Matter, Juerg; Stute, Martin; Takahashi, Taro; Goldberg, David

    2015-01-01

    In addition to efforts aimed at reducing anthropogenic production of greenhouse gases, geological storage of CO2 is being explored as a strategy to reduce atmospheric greenhouse gas emission and mitigate climate change. Previous studies of the deep subsurface in North America have not fully considered the potential negative effects of CO2 leakage into shallow drinking water aquifers, especially from a microbiological perspective. A test well in the Newark Rift Basin was utilized in two field experiments to investigate patterns of microbial succession following injection of CO2-saturated water into an isolated aquifer interval, simulating a CO2 leakage scenario. A decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), and increased bacterial cell concentrations in the recovered water. 16S ribosomal RNA gene sequence libraries from samples collected before and after the test well injection were compared to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injections, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia and microbial taxa often noted to be associated with iron and sulfate reduction. The concurrence of increased microbial cell concentrations and rapid microbial community succession indicate significant changes in aquifer microbial communities immediately following the experimental CO2 leakage event. Samples collected one year post-injection were similar in cell number to the original background condition and community composition, although not identical, began to revert toward the pre-injection condition, indicating microbial resilience following a leakage disturbance. This study provides a first glimpse into the in situ successional response of microbial communities to CO2 leakage after subsurface injection in the Newark Basin and the potential microbiological impact of CO2 leakage on drinking water resources. PMID:25635675

  7. Groundwater modeling to evaluate interaquifer leakage in the Floridan aquifer system near Hunter Army Airfield and Fort Stewart

    USGS Publications Warehouse

    Cherry, Gregory S.

    2011-01-01

    Simulations using a modified regional groundwater- flow model were used to determine the amount of leakage from the Upper Floridan aquifer (UFA) through the Lower Floridan confining unit (LFC) into the Lower Floridan aquifer (LFA) resulting from pumping about 1 million gallons per day at newly constructed LFA production wells at Hunter Army Airfield and Fort Stewart in coastal Georgia. Simulated steadystate drawdown at each of the LFA production wells closely matched observed drawdown during a 72-hour aquifer test with the observed water levels reaching steady-state by the end of the test period. However, simulated drawdown was greater than observed drawdown in the UFA because of the short duration of the aquifer test and the time required for groundwater movement through the LFC into the LFA. Steadystate simulations provide an estimate of leakage based on the long-term continuous operation of each production well. Results of model simulations indicate that interaquifer leakage accounts for 48 percent of the flow to the well at Hunter Army Airfield, and 98 percent of the flow to the well at Fort Stewart. Simulated results near the Hunter Army Airfield production well indicated that 65 percent of the leakage from the UFA to the LFA occurs within a 1-mile radius, whereas simulated results near the Fort Stewart production well indicated 80-percent leakage from the UFA to the LFA within the same radius. The greater amount of leakage to the production well near Fort Stewart can be attributed to the higher transmissivity of the UFA and higher vertical hydraulic conductivity in the LFC near the well.

  8. Space Station Freedom seal leakage rate analysis and testing summary: Air leaks in ambient versus vacuum exit conditions

    NASA Technical Reports Server (NTRS)

    Rodriguez, P. I.; Markovitch, R.

    1992-01-01

    This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.

  9. Thermoplastic fusion bonding using a pressure-assisted boiling point control system.

    PubMed

    Park, Taehyun; Song, In-Hyouk; Park, Daniel S; You, Byoung Hee; Murphy, Michael C

    2012-08-21

    A novel thermoplastic fusion bonding method using a pressure-assisted boiling point (PABP) control system was developed to apply precise temperatures and pressures during bonding. Hot embossed polymethyl methacrylate (PMMA) components containing microchannels were sealed using the PABP system. Very low aspect ratio structures (AR = 1/100, 10 μm in depth and 1000 μm in width) were successfully sealed without collapse or deformation. The integrity and strength of the bonds on the sealed PMMA devices were evaluated using leakage and rupture tests; no leaks were detected and failure during the rupture tests occurred at pressures greater than 496 kPa. The PABP system was used to seal 3D shaped flexible PMMA devices successfully.

  10. Field demonstration of CO2 leakage detection and potential impacts on groundwater quality at Brackenridge Field Laboratory

    NASA Astrophysics Data System (ADS)

    Zou, Y.; Yang, C.; Guzman, N.; Delgado, J.; Mickler, P. J.; Horvoka, S.; Trevino, R.

    2015-12-01

    One concern related to GCS is possible risk of unintended CO2 leakage from the storage formations into overlying potable aquifers on underground sources of drinking water (USDW). Here we present a series of field tests conducted in an alluvial aquifer which is on a river terrace at The University of Texas Brackenridge Field Laboratory. Several shallow groundwater wells were completed to the limestone bedrock at a depth of 6 m and screened in the lower 3 m. Core sediments recovered from the shallow aquifer show that the sediments vary in grain size from clay-rich layers to coarse sandy gravels. Two main types of field tests were conducted at the BFL: single- (or double-) well push-pull test and pulse-like CO2 release test. A single- (or double-) well push-pull test includes three phases: the injection phase, the resting phase and pulling phase. During the injection phase, groundwater pumped from the shallow aquifer was stored in a tank, equilibrated with CO2 gasand then injected into the shallow aquifer to mimic CO2 leakage. During the resting phase, the groundwater charged with CO2 reacted with minerals in the aquifer sediments. During the pulling phase, groundwater was pumped from the injection well and groundwater samples were collected continuously for groundwater chemistry analysis. In such tests, large volume of groundwater which was charged with CO2 can be injected into the shallow aquifer and thus maximize contact of groundwater charged with CO2. Different than a single- (or double-) well push-pull test, a pulse-like CO2 release test for validating chemical sensors for CO2 leakage detection involves a CO2 release phase that CO2 gas was directly bubbled into the testing well and a post monitoring phase that groundwater chemistry was continuously monitored through sensors and/or grounder sampling. Results of the single- (or double-) well push-pull tests conducted in the shallow aquifer shows that the unintended CO2 leakage could lead to dissolution of carbonates and some silicates and mobilization of heavy metals from the aquifer sediments to groundwater, however, such mobilization posed no risks on groundwater quality at this site. The pulse-like tests have demonstrated it is plausible to use chemical sensors for CO2 leakage detection in groundwater.

  11. Study of true-remanent polarization using remanent hysteresis task and resistive leakage analysis in ferroelectric 0.64Pb(Mg1/3Nb2/3)O3-0.36PbTiO3 ceramics

    NASA Astrophysics Data System (ADS)

    Joseph, Abhilash J.; Kumar, Binay

    2018-03-01

    The conventionally reported value of remanent polarization (Pr) contains contribution from non-remanent components which are not usable for memory device applications. This report presents techniques which extract the true-remanent (intrinsic) component of polarization after eliminating the non-remanent component in ferroelectric ceramics. For this, "remanent hysteresis task" and "positive-up-negative-down technique" were performed which utilized the switchable properties of polarizations to nullify the contributions from the non-remanent (non-switchable) components. The report also addresses the time-dependent leakage behavior of the ceramics focusing on the presence of resistive leakage (a time-dependent parameter) present in the ceramics. The techniques presented here are especially useful for polycrystalline ceramics where leakage current leads to an erroneous estimation of Pr.

  12. 75 FR 53353 - Notice of Availability of Final Interim Staff Guidance Document No. 25 “Pressure and Helium...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... Guidance Document No. 25 ``Pressure and Helium Leakage Testing of the Confinement Boundary of Spent Fuel...: The Division of Spent Fuel Storage and Transportation (SFST) of the Office of Nuclear Materials Safety... Helium Leakage Testing of the Confinement Boundary of Spent Fuel Dry Storage Systems.'' This ISG...

  13. Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage

    PubMed Central

    Siegel, Rolland

    2014-01-01

    Background Significant paravalvular leakage after transcatheter aortic valve implantation (TAVI) correlates with increased morbidity and mortality, but adverse consequences of trivial paravalvular leakage have stimulated few investigations. Using a unique method distinctly different from other diagnostic approaches, we previously reported elevated backflow velocities of short duration (transients) in mechanical valve closure. In this study, similar transients were found in a transcatheter valve paravalvular leakage avatar. Methods Paravalvular leakage rate (zero to 58 mL/second) and aortic valve incompetence (volumetric back flow/forward flow; zero to 32%) were made adjustable using a mock transcatheter aortic valve device and tested in quasi-steady and pulsatile flow test systems. Projected dynamic valve area (PDVA) from the back illuminated mock transcatheter aortic valve device was measured and regional backflow velocities were derived by dividing volumetric flow rate by the PDVA over the open and closing valve phase and the total closed valve area derived from backflow leakage. Results Aortic incompetence from 1-32% generated negative backflow transients from 8 to 267 meters/second, a range not dissimilar to that measured in mechanical valves with zero paravalvular leakage. Optimal paravalvular leakage was identified; not too small generating high backflow transients, not too large considering volume overload and cardiac energy loss caused by defective valve behavior and fluid motion. Conclusions Thrombogenic potential of transcatheter aortic valves with trivial aortic incompetence and high magnitude regional backflow velocity transients was comparable to mechanical valves. This may have relevance to stroke rate, asymptomatic microembolic episodes and indications for anticoagulation therapy after transcatheter valve insertion. PMID:25333018

  14. Prevention of Cold Damage to Container-Grown Longleaf Pine Roots

    Treesearch

    Richard W. Tinus; Mary Anne Sword; James P. Barnett

    2002-01-01

    When longleaf pine (Pinus palustris Mill.) seedlings are container-grown in open fields, their roots may be exposed to damaging, cold temperatures. Major losses in some nurseries have occurred. Between November 1996 and February 1997, we measured the cold hardiness of container-grown longleaf pine roots by measuring electrolyte leakage (a) of...

  15. The Effects of Alarm Display, Processing, and Availability on Crew Performance

    DTIC Science & Technology

    2000-11-01

    snow Instrumentation line leakage Small LOCA Steam generator tube rupture Small feedwater leakage inside containment Cycling of main steam...implemented. • Due to primary pressure controller failure, pressure heater banks cycle between on and off. 8.00 CF1 CF2 CF3 CF4 CF5...temperatures after the high-pressure pre- heaters flows into the steam generators number of active emergency feedwater pumps openings of the condensate

  16. Fuel containment and damage tolerance in large composite primary aircraft structures. Phase 2: Testing

    NASA Technical Reports Server (NTRS)

    Sandifer, J. P.; Denny, A.; Wood, M. A.

    1985-01-01

    Technical issues associated with fuel containment and damage tolerance of composite wing structures for transport aircraft were investigated. Material evaluation tests were conducted on two toughened resin composites: Celion/HX1504 and Celion/5245. These consisted of impact, tension, compression, edge delamination, and double cantilever beam tests. Another test series was conducted on graphite/epoxy box beams simulating a wing cover to spar cap joint configuration of a pressurized fuel tank. These tests evaluated the effectiveness of sealing methods with various fastener types and spacings under fatigue loading and with pressurized fuel. Another test series evaluated the ability of the selected coatings, film, and materials to prevent fuel leakage through 32-ply AS4/2220-1 laminates at various impact energy levels. To verify the structural integrity of the technology demonstration article structural details, tests were conducted on blade stiffened panels and sections. Compression tests were performed on undamaged and impacted stiffened AS4/2220-1 panels and smaller element tests to evaluate stiffener pull-off, side load and failsafe properties. Compression tests were also performed on panels subjected to Zone 2 lightning strikes. All of these data were integrated into a demonstration article representing a moderately loaded area of a transport wing. This test combined lightning strike, pressurized fuel, impact, impact repair, fatigue and residual strength.

  17. Comprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage

    PubMed Central

    Pan, Yu-Ning; Tang, Yi-Fan; Zhang, Jie; Wang, Guo-Yao; Huang, Qiu-Li

    2017-01-01

    The present study aims to investigate and compare the diagnostic and prognostic value of cavernosography with 320-row dynamic volume computed tomography (DVCT) versus conventional cavernosography in men with erectile dysfunction (ED) caused by venous leakage. A total of 174 patients diagnosed with ED were enrolled and received cavernosography with 320-row DVCT (DVCT group) and conventional cavernosography scans (control group) respectively. The diagnosis, complications, and prognosis of patients were evaluated. The DVCT group provided high-resolution images with less processing and testing time, as well as lowered radiological agent and contrast agent compared with the control group. In the DVCT group, 89 patients who were diagnosed with venous ED had six various venous leakage, namely superficial venous leakage, profundus venous leakage, the mixed type, cavernosal venous leakage, crural venous leakage, and also venous leakage between the penis and urethra cavernosum (9, 21, 32, 6, 18, and 3 cases respectively). Similarly, 74 patients out of the 81 who suffered from venous ED were classified to have superficial venous leakage (11), profundus venous leakage (14), the mixed type venous leakage (26), and middle venous leakage (23). Six out of 25 patients in the DVCT group, had improvements in ED while the remaining 19 achieved full erectile function recovery with no penile fibrosis and erectile pain. Cavernosography with 320-row DVCT is a reliable system that can be used to diagnose ED caused by venous leakage. This is especially useful in accurately determining the type of venous and allows for a better prognosis and direction of treatment. PMID:28424371

  18. Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Hunter Army Airfield, Chatham County, Georgia

    USGS Publications Warehouse

    Clarke, John S.; Williams, Lester J.; Cherry, Gregory C.

    2010-01-01

    Test drilling and field investigations, conducted at Hunter Army Airfield (HAAF), Chatham County, Georgia, during 2009, were used to determine the geologic, hydraulic, and water-quality characteristics of the Floridan aquifer system and to evaluate the effect of Lower Floridan aquifer (LFA) pumping on the Upper Floridan aquifer (UFA). Field investigation activities included (1) constructing a 1,168-foot (ft) test boring and well completed in the LFA, (2) collecting drill cuttings and borehole geophysical logs, (3) collecting core samples for analysis of vertical hydraulic conductivity and porosity, (4) conducting flowmeter and packer tests in the open borehole within the UFA and LFA, (5) collecting depth-integrated water samples to assess basic ionic chemistry of various water-bearing zones, and (6) conducting aquifer tests in the new LFA well and in an existing UFA well to determine hydraulic properties and assess interaquifer leakage. Using data collected at the site and in nearby areas, model simulation was used to quantify the effects of interaquifer leakage on the UFA and to determine the amount of pumping reduction required in the UFA to offset drawdown resulting from the leakage. Borehole-geophysical and flowmeter data indicate the LFA at HAAF consists of limestone and dolomitic limestone between depths of 703 and 1,080 ft, producing water from six major permeable zones: 723-731; 768-785; 818-837; 917-923; 1,027-1,052; and 1,060-1,080 ft. Data from a flowmeter survey, conducted at a pumping rate of 748 gallons per minute (gal/min), suggest that the two uppermost zones contributed 469 gal/min or 62.6 percent of the total flow during the test. The remaining four zones contributed from 1.7 to 18 percent of the total flow. Grab water samples indicate that with the exception of fluoride, constituent concentrations in the LFA increased with depth; water from the deepest interval (1,075 ft) contained chloride and sulfate concentrations of 480 and 240 milligrams per liter (mg/L), respectively. These relatively high concentrations were interpreted to have little effect on the overall quality of the well because flowmeter results indicated that water from 1,060 to 1,080 ft contributed less than 2 percent of the total flow to the completed well. Results of a 72-hour aquifer test indicate that pumping a LFA well at a rate of 748 gal/min produced a drawdown response of 0.76 ft in a well completed in the UFA located 176 ft from the pumped well. A revised regional groundwater-flow model was used to simulate long-term (steady-state) leakage response of the UFA to pumping from the LFA and to estimate the equivalent amount of pumping from the UFA that would produce similar drawdown. Pumping the well at a rate of 748 gal/min (about 1 million gallons per day [Mgal/d]) resulted in a maximum simulated steady-state drawdown of 36.2 ft in the LFA and was greater than 1 ft over a 146 square-mile area. Simulated steady-state drawdown in the overlying UFA that resulted from interaquifer leakage was greater than 1 ft over a 141 square-mile area and was 2.03 ft at the pumped well. Flow to the pumped well was derived from increased lateral flow across the specified-head boundary (0.02 Mgal/d) and increased leakage from the UFA (0.52 Mgal/d), and by reductions in discharge to the Lower Floridan confining unit (0.53 Mgal/d) and to the lateral specified-head boundary (0.53 Mgal/d). Sixty-five percent of the leakage from the UFA occurred within 1 mile of the pumped well. This larger contribution results from a larger head gradient between the pumped well and the overlying aquifer in areas close to the pumped well. The Georgia Environmental Protection Division interim permitting strategy for the LFA requires simulation of (1) aquifer leakage from the UFA to LFA resulting from pumping the new LFA well, and (2) the equivalent rate of UFA pumping that induces the identical maximum drawdown in the UFA that would be expected as a result of pumping th

  19. Sealant Microleakage After Using Nano-Filled Bonding Agents on Saliva-Contaminated Enamel

    PubMed Central

    Paryab, Mehrsa

    2013-01-01

    Objective: The efficacy of correctly applied fissure sealants has been revealed in the prevention of caries. Saliva and moisture contamination of the etched enamel surface before sealant placement can decrease the bonding strength of the sealant to the enamel. The aim of this study was to test the new bonding agents containing nano-fillers in order to reduce the negative effect of saliva contamination on the sealant micro leakage. Materials and Methods: Seventy five sound human premolars were randomly assigned to five equal groups as follows: Group A: etching, sealant; Group B: etching, saliva contamination, sealant; Group C: etching, saliva contamination, Single bond, sealant; Group D: etching, saliva contamination, Adper Single bond 2, sealant; Group E: etching, saliva contamination, N Bond, sealant. The samples were thermo-cycled and immersed in basic fuchsine 0.5% by weight. Then, the teeth were sectioned bucco-lingually and parallel to the long axis into two segments. Finally, the length of dye penetration at the sealant-tooth interface was scored according to a four-point scale. Results: Micro-leakage was higher in group B compared to the other groups, while there were no differences among the evaluated dentin adhesives. Conclusion: The use of nano-filled bonding agents as an intermediate layer between the etched enamel and the sealant can reduce sealant micro-leakage after saliva contamination at the level of the uncontaminated enamel. PMID:25512749

  20. Biliary complications after right lobe living donor liver transplantation: a single-centre experience

    PubMed Central

    Yaprak, Onur; Dayangac, Murat; Akyildiz, Murat; Demirbas, Tolga; Guler, Necdet; Bulutcu, Fisun; Bassullu, Nuray; Akun, Elif; Yuzer, Yildiray; Tokat, Yaman

    2012-01-01

    Background Biliary complications that developed after right lobe liver transplantation from living donors were studied in a single centre. Methods From 2004 to 2010, 200 consecutive living donor right lobe liver transplantations were performed. The database was evaluated retrospectively. Biliary complications were diagnosed according to clinical, biochemical and radiological tests. The number of biliary ducts in the transplanted graft, the surgical techniques used for anastomosis, biliary strictures and bile leakage rates were analysed. Results Of a total of 200 grafts, 117 invloved a single bile duct, 77 had two bile ducts and in six grafts there were three bile ducts. In 166 transplants, the anastomosis was performed as a single duct to duct, in 21 transplants double duct to ducts, in one transplant, three duct to ducts and in 12 transplants as a Roux-en-Y reconstruction. In all, 40 bile leakages (20%) and 17 biliary strictures (8.5%) were observed in 49 patients resulting in a total of 57 biliary complications (28.5%). Seventeen patients were re-operated (12 as a result of bile leakages and five owing to biliary strictures). Conclusion Identification of more than one biliary orifice in the graft resulted in an increase in the complication rates. In grafts containing multiple orifices, performing multiple duct-to-duct (DD) or Roux-en-Y anastomoses led to a lower number of complications. PMID:22151451

  1. Effect of Intra-Orifice Depth on Sealing Ability of Four Materials in the Orifices of Root-Filled Teeth: An Ex-Vivo Study

    PubMed Central

    Ghulman, Motaz Ahmad; Gomaa, Madiha

    2012-01-01

    Aim. To investigate the effect of orifice cavity depth on the sealing ability of Fusio, Fuji II, Fuji IX, and MTA“G”. Materials and Methods. Ninety-two canals in extracted mandibular premolars were prepared, obturated, and randomly grouped into 4 groups. Each group was subgrouped for a 2 mm and 3 mm orifice cavity depth (n = 10). The remaining roots were divided to serve as positive and negative controls (n = 6). Cavities of the 4 experimental groups were filled with the respective materials and subjected to methylene blue dye leakage. Linear leakage was measured in mm using a stereomicroscope. Statistical Analysis. Kruskall-Wallis test was used at P < 0.05, and t-test was done to compare 2 mm and 3 mm. Results. All tested materials leaked to various degrees. Significantly higher leakage score was found for Fuji IX, Fusio, Fuji II, and MTA “G” in a descending order, when the materials were placed at 3 mm depths. A significant difference was found in the leakage score between the 2 mm and 3 mm depths in all tested materials with the 3 mm depth showing a greater leakage score in all tested materials. Exception was in MTA “G” at 2 mm and 3 mm depths (0.551 mm ± 0.004 mm and 0.308 mm ± 0.08 mm, resp.). Conclusion. The null hypothesis should be partially rejected. Fusio and MTA “G” were affected by orifice cavity depth with regard to their sealing ability. MTA “G” had the least leakage when placed at 2 or 3 mm depths, and Fusio is the next when placed at 2 mm depth. Two millimeters orifice cavity depth is suitable for most adhesive orifice barrier materials. PMID:22675356

  2. Application of Arrester Simulation Device in Training

    NASA Astrophysics Data System (ADS)

    Baoquan, Zhang; Ziqi, Chai; Genghua, Liu; Wei, Gao; Kaiyue, Wu

    2017-12-01

    Combining with the arrester simulation device put into use successfully, this paper introduces the application of arrester test in the insulation resistance measurement, counter test, Leakage current test under DC 1mA voltage and leakage current test under 0.75U1mA. By comparing with the existing training, this paper summarizes the arrester simulation device’s outstanding advantages including real time monitoring, multi-type fault data analysis and acousto-optic simulation. It effectively solves the contradiction between authenticity and safety in the existing test training, and provides a reference for further training.

  3. Test results for rotordynamic coefficients of anti-swirl self-injection seals

    NASA Technical Reports Server (NTRS)

    Kim, C. H.; Lee, Y. B.

    1994-01-01

    Test results are presented for rotordynamic coefficients and leakage for three annular seals which use anti-swirl self-injection concept to yield significant improvement in whirl frequency ratios as compared to smooth and damper seals. A new anti-swirl self-inection mechanism is achieved by deliberately machining self-injection holes inside the seal stator mechanism which is used to achieve effective reduction of the tangential flow which is considered as a prime cause of rotor instability in high performance turbomachinery. Test results show that the self-injection mechanism significantly improves whirl frequency ratios; however, the leakage performance degrades due to the introduction of the self-injection mechanism. Through a series of the test program, an optimum anti-swirl self-injection seal which uses a labyrinth stator surface with anti-axial flow injections is selected to obtain a significant improvement in the whirl frequency ratio as compared to a damper seal, while showing moderate leakage performance. Best whirl frequency ratio is achieved by an anti-swirl self-injection seal of 12 holes anti-swirl and 6 degree anti-leakage injection with a labyrinth surface configuration. When compared to a damper seal, the optimum configuration outperforms the whirl frequency ratio by a factor of 2.

  4. Cochlin-tomoprotein (CTP) detection test identified perilymph leakage preoperatively in revision stapes surgery.

    PubMed

    Kataoka, Yuko; Ikezono, Tetsuo; Fukushima, Kunihiro; Yuen, Koji; Maeda, Yukihide; Sugaya, Akiko; Nishizaki, Kazunori

    2013-08-01

    Perilymphatic fistula (PLF) is defined as an abnormal leakage between perilymph from the labyrinth to the middle ear. Symptoms include hearing loss, tinnitus, and vertigo. The standard mode of PLF detection is intraoperative visualization of perilymph leakage and fistula, which ostensibly confirms the existence of PLF. Other possible methods of diagnosis include confirmation of pneumolabyrinth via diagnostic imaging. Recently, a cochlin-tomoprotein (CTP) detection test has been developed that allows definitive diagnosis of PLF-related hearing loss. We report the case of a 45-year-old man who presented with right-sided tinnitus, hearing loss, and dizziness 30 years after stapes surgery. Middle ear lavage was performed after myringotomy. A preoperative diagnosis of PLF was reached using the CTP detection test. Intraoperative observations included a necrotic long process of the incus, displaced wire piston, and fibrous tissue in the oval window. Perilymph leakage was not evident. The oval window was closed with fascia, and vertigo disappeared within 2 weeks postoperatively. When PLF is suspected after stapes surgery, the CTP detection test can be a useful, highly sensitive, and less invasive method for preoperative diagnosis. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Seal Investigations of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Taylor, Shawn; Oswald, Jay; DeCastro, Jonathan A.

    2006-01-01

    In an effort to improve upon current thermal active clearance control methods, a first generation, fast-acting mechanically actuated, active clearance control system has been designed and installed into a non-rotating test rig. In order to harvest the benefit of tighter blade tip clearances, low-leakage seals are required for the actuated carrier segments of the seal shroud to prevent excessive leakage of compressor discharge (P3) cooling air. The test rig was designed and fabricated to facilitate the evaluation of these types of seals, identify seal leakage sources, and test other active clearance control system concepts. The objective of this paper is to present both experimental and analytical investigations into the nature of the face-seal to seal-carrier interface. Finite element analyses were used to examine face seal contact pressures and edge-loading under multiple loading conditions, varied E-seal positions and two new face seal heights. The analyses indicated that moving the E-seal inward radially and reducing face seal height would lead to more uniform contact conditions between the face seal and the carriers. Lab testing confirmed that moving the balance diameter inward radially caused a decrease in overall system leakage.

  6. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, Armin

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.« less

  7. Effectiveness of a novel home-based testing device for the detection of rupture of membranes.

    PubMed

    Bornstein, Jacob; Ohel, Gonen; Sorokin, Yoram; Reape, Kathleen Z; Shnaider, Oleg; Kessary-Shoham, Hadar; Ophir, Ella

    2009-01-01

    We evaluated the ability of a testing panty liner (TPL) embedded with a pH/ammonia indicator polymer to differentiate amniotic fluid leakage from urine. A multicenter, open-label study in which 339 pregnant women (age 18 to 45 years, minimum 16 weeks' gestation, presenting with unexplained vaginal wetness) were enrolled. The TPL was worn and the results read by the subject and a health care provider (HCP) who was blinded to the subject's reading. Results were compared with the standard clinical diagnosis, as determined by direct visualization of vaginal pooling, crystallization (ferning), and nitrazine tests, performed by a second blinded HCP. Subject experience with the test was assessed with a brief questionnaire. The TPL accurately detected 154 of the 161 subjects found to have amniotic fluid leakage by the standard diagnosis; thus, the sensitivity of the TPL was 95.65%. The specificity was 84.46% (% true negative readings), as the TPL demonstrated a negative result for 125 of the 148 subjects whose clinical diagnosis was negative for amniotic fluid leakage. The overall agreement between the TPL readings of the clinician and that of the subject was 97.40%. The TPL is a reliable test to determine the presence of amniotic fluid leakage.

  8. Monitoring underground water leakage pattern by ground penetrating radar (GPR) using 800 MHz antenna frequency

    NASA Astrophysics Data System (ADS)

    Amran, T. S. T.; Ismail, M. P.; Ahmad, M. R.; Amin, M. S. M.; Ismail, M. A.; Sani, S.; Masenwat, N. A.; Basri, N. S. M.

    2018-01-01

    Water is the most treasure natural resources, however, a huge amount of water are lost during its distribution that leads to water leakage problem. The leaks meant the waste of money and created more economic loss to treat and fix the damaged pipe. Researchers and engineers have put tremendous attempts and effort, to solve the water leakage problem especially in water leakage of buried pipeline. An advanced technology of ground penetrating radar (GPR) has been established as one of the non-destructive testing (NDT) method to detect the underground water pipe leaking. This paper focuses on the ability of GPR in water utility field especially on detection of water leaks in the underground pipeline distribution. A series of laboratory experiments were carried out using 800-MHz antenna, where the performance of GPR on detecting underground pipeline and locating water leakage was investigated and validated. A prototype to recreate water-leaking system was constructed using a 4-inch PVC pipe. Different diameter of holes, i.e. ¼ inch, ½ inch, and ¾ inch, were drilled into the pipe to simulate the water leaking. The PVC pipe was buried at the depth of 60 cm into the test bed that was filled with dry sand. 15 litres of water was injected into the PVC pipe. The water leakage patterns in term of radargram data were gathered. The effectiveness of the GPR in locating the underground water leakage was ascertained, after the results were collected and verified.

  9. Apical sealing ability of Resilon/Epiphany versus gutta-percha/AH Plus: immediate and 16-months leakage.

    PubMed

    Paqué, F; Sirtes, G

    2007-09-01

    To compare the long-term apical sealing ability of gutta-percha/AH Plus and Resilon/Epiphany. The root canals of 90 single-rooted human mandibular premolars with single narrow root canals were prepared with ProFile 0.4 taper instruments to apical size 40. After each instrument, the canals were irrigated with 1% sodium hypochlorite. Subsequently, the teeth were randomly divided into four groups containing 20 teeth each. Additionally, 10 prepared premolars served as positive and 10 counterparts with intact crowns as negative controls. The root canals were filled with gutta-percha/AH Plus or Resilon/Epiphany using lateral or vertical compaction. Specimens were allowed to set for 7 days at 37 degrees C and 100% humidity. Subsequently, the root fillings were removed down to the apical 4 mm. Fluid movement was then assessed using a fluid transportation model and re-evaluated after 16 months of water storage. Leakage within and between groups was compared using nonparametric tests. Negative controls revealed no fluid movement and positive controls displayed gross fluid movement at both times of observation. At the immediate measurement, there were no significant differences between the experimental groups (Kruskal-Wallis, P > 0.05). Gutta-percha/AH Plus fillings retained their seal after 16-months storage (Wilcoxon, P > 0.05), whilst the Resilon/Epiphany groups lost their sealing capacity (Wilcoxon, P < 0.001). In these groups, 29 of the 40 specimens exhibited gross leakage similar to positive controls. Initially, Resilon/Epiphany root fillings prevented fluid movement to the same degree as gutta-percha/AH Plus counterparts, but showed more fluid movement when tested at 16 months.

  10. A PROBABILISTIC METHOD FOR ESTIMATING MONITORING POINT DENSITY FOR CONTAINMENT SYSTEM LEAK DETECTION

    EPA Science Inventory

    The use of physical and hydraulic containment systems for the isolation of contaminated ground water and aquifer materials ssociated with hazardous waste sites has increased during the last decade. The existing methodologies for monitoring and evaluating leakage from hazardous w...

  11. Development of circumferential seal for helicopter transmissions: Results of bench and flight tests

    NASA Technical Reports Server (NTRS)

    Strom, T. N.; Ludwig, L. P.

    1975-01-01

    A modified circumferential segmented ring seal was designed for direct replacement of a helicopter transmission elastomeric lip seal operating on a shaft diameter of 13.91 centimeters (5.481 in.) at sliding velocities to 52.48 m/sec (10 330 ft/min). The modifications involved the garter spring tension, shaft roundness, seal housing flatness, and pumping grooves to inhibit leakage. Operation of the seals in bench tests under simulated helicopter transmission conditions revealed that the seal leakage rate was within acceptable limits and that the wear rate was negligible. The low leakage and wear rates were confirmed in flight tests of 600 and 175 hours (sliding speed, 48.11 m/sec (9470 ft/min)). An additional 200 hours of air worthiness qualification testing (aircraft tie down) demonstrated that the seal can operate at the advanced sliding conditions of 52.48 m/sec (10 330 ft/min).

  12. Development of spiral-groove self-acting seals for helicopter engines

    NASA Technical Reports Server (NTRS)

    Obrien, M.

    1979-01-01

    A spiral-groove, self-acting face seal was rig tested at advanced gas turbine operating conditions to determine wear and leakage rates. The spiral-groove, self-acting geometry was located in the rotating seal seat. Seal component wear induced by start-stop operation was measured after subjecting the test seal to 176 start-stop cycles. Wear occurring during normal operation was documented throughout a 75-hour endurance test. Seal air leakage was also measured. During endurance operation, the seal was subjected to operating conditions bounded by the values surface speed - 244 m/s (800 ft/sec), air pressure - 148 N/sq cm abs (215 psia), and air temperature - 622 K (660 F). The post-test condition of the seal components was documented. Wear data is presented in tabular form, while seal air leakage is presented graphically, as a function of pressure and speed.

  13. Field Testing of Compartmentalization Methods for Multifamily Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Lstiburek, J.

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In thismore » project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).« less

  14. Air Leakage Measurements in Navy Family Housing Units at Norfolk, Virginia.

    DTIC Science & Technology

    1983-04-01

    80-4233), Prepared for Naval Construction Battalion Center (1980). 17. Lagus, P.L., "Air Leakage Measurements in Support of the Johns Manville Corporation...in the Advanced Energy Utilization Test Bed, Pt. Hueneme, California," Systems, Science and Software Report (SSS-R-78-3533), Prepared for Johns ... Manville Corporation (1978). 18. Weidt, J.L., J. Weidt, S. Selkowitz, "Field Air Leakage of Newly Installed Residential Windows," Proceedings of ASHRAE

  15. Screening and ranking framework (SRF) for geologic CO2 storagesite selection on the basis of HSE risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Curtis M.

    2006-11-27

    A screening and ranking framework (SRF) has been developedto evaluate potential geologic carbon dioxide (CO2) storage sites on thebasis of health, safety, and environmental (HSE) risk arising from CO2leakage. The approach is based on the assumption that CO2 leakage risk isdependent on three basic characteristics of a geologic CO2 storage site:(1) the potential for primary containment by the target formation; (2)the potential for secondary containment if the primary formation leaks;and (3) the potential for attenuation and dispersion of leaking CO2 ifthe primary formation leaks and secondary containment fails. Theframework is implemented in a spreadsheet in which users enter numericalscores representingmore » expert opinions or published information along withestimates of uncertainty. Applications to three sites in Californiademonstrate the approach. Refinements and extensions are possible throughthe use of more detailed data or model results in place of propertyproxies.« less

  16. Advanced Duct Sealing Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Walker, Iain S.

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected weekly. The baking test specimens were visually inspected weekly, and the durability was judged by the observed deterioration in terms of brittleness, cracking, flaking and blistering (the terminology used in the UL 181B-FX test procedure).« less

  17. Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems.

    PubMed

    Fu, T Y; Gent, P; Kumar, V

    2012-03-01

    This was a head-to-head comparison of two hydrogen-peroxide-based room decontamination systems. To compare the efficacy, efficiency and safety of hydrogen peroxide vapour (HPV; Clarus R, Bioquell, Andover, U.K.) and aerosolized hydrogen peroxide (aHP; SR2, Sterinis, now supplied as Glosair, Advanced Sterilization Products (ASP), Johnson & Johnson Medical Ltd, Wokingham, U.K.) room disinfection systems. Efficacy was tested using 4- and 6-log Geobacillus stearothermophilus biological indicators (BIs) and in-house prepared test discs containing approximately 10(6) meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile and Acinetobacter baumannii. Safety was assessed by detecting leakage of hydrogen peroxide using a hand-held detector. Efficiency was assessed by measuring the level of hydrogen peroxide using a hand-held sensor at three locations inside the room, 2 h after the start of the cycles. HPV generally achieved a 6-log reduction, whereas aHP generally achieved less than a 4-log reduction on the BIs and in-house prepared test discs. Uneven distribution was evident for the aHP system but not the HPV system. Hydrogen peroxide leakage during aHP cycles with the door unsealed, as per the manufacturer's operating manual, exceeded the short-term exposure limit (2 ppm) for more than 2 h. When the door was sealed with tape, as per the HPV system, hydrogen peroxide leakage was <1 ppm for both systems. The mean concentration of hydrogen peroxide in the room 2 h after the cycle started was 1.3 [standard deviation (SD) 0.4] ppm and 2.8 (SD 0.8) ppm for the four HPV and aHP cycles, respectively. None of the readings were <2 ppm for the aHP cycles. The HPV system was safer, faster and more effective for biological inactivation. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  18. Integrated circuit electrometer and sweep circuitry for an atmospheric probe

    NASA Technical Reports Server (NTRS)

    Zimmerman, L. E.

    1971-01-01

    The design of electrometer circuitry using an integrated circuit operational amplifier with a MOSFET input is described. Input protection against static voltages is provided by a dual ultra low leakage diode or a neon lamp. Factors affecting frequency response leakage resistance, and current stability are discussed, and methods are suggested for increasing response speed and for eliminating leakage resistance and current instabilities. Based on the above, two practical circuits, one having a linear response and the other a logarithmic response, were designed and evaluated experimentally. The design of a sweep circuit to implement mobility measurements using atmospheric probes is presented. A triangular voltage waveform is generated and shaped to contain a step in voltage from zero volts in both positive and negative directions.

  19. [Reflection on the present study of anastomotic leakage after colorectal surgery].

    PubMed

    Wu, Zhouqiao; Shi, Jinyao; Li, Ziyu; Ji, Jiafu

    Anastomotic leakage is one of the most serious complications of colorectal surgery. Despite progress in available surgical techniques, the morbidity associated with anastomotic leakage remains high. In this review, we summarize the current clinical status of this complication, the problems it causes, and relevant research achievements. To date, a lack of consensus regarding the diagnosis of anastomotic leakage has resulted in varying rates of diagnosis across countries and regions worldwide. Accurately predicting the occurrence of anastomotic leakage using the established risk factors and preoperative scoring systems remains difficult. Many of the described preventive measures, including defunctioning stoma creation, positive air leak testing, and use of effective tissue adhesives, remain controversial; more evidence-based medical information is urgently needed. Delayed diagnoses of anastomotic leakage also remain common in clinical practice. To prevent catastrophic outcomes, such as reoperations or deaths, early diagnosis is critically important. Parameters local to the area of the anastomosis may facilitate early detection of leakage, but their effectiveness is subject to clinical validation. Lastly, the pathological etiology of anastomotic leakage remains to be determined, and its elucidation may inspire innovative interventions that solve this critical surgical complication.

  20. Mechanism of leakage of ion-implantation isolated AlGaN/GaN MIS-high electron mobility transistors on Si substrate

    NASA Astrophysics Data System (ADS)

    Zhang, Zhili; Song, Liang; Li, Weiyi; Fu, Kai; Yu, Guohao; Zhang, Xiaodong; Fan, Yaming; Deng, Xuguang; Li, Shuiming; Sun, Shichuang; Li, Xiajun; Yuan, Jie; Sun, Qian; Dong, Zhihua; Cai, Yong; Zhang, Baoshun

    2017-08-01

    In this paper, we systematically investigated the leakage mechanism of the ion-implantation isolated AlGaN/GaN metal-insulator-semiconductor high electron mobility transistors (MIS-HEMTs) on Si substrate. By means of combined DC tests at different temperatures and electric field dependence, we demonstrated the following original results: (1) It is proved that gate leakage is the main contribution to OFF-state leakage of ion-implantation isolated AlGaN/GaN MIS-HEMTs, and the gate leakage path is a series connection of the gate dielectric Si3N4 and Si3N4-GaN interface. (2) The dominant mechanisms of the leakage current through LPCVD-Si3N4 gate dielectric and Si3N4-GaN interface are identified to be Frenkel-Poole emission and two-dimensional variable range hopping (2D-VRH), respectively. (3) A certain temperature annealing could reduce the density of the interface state that produced by ion implantation, and consequently suppress the interface leakage transport, which results in a decrease in OFF-state leakage current of ion-implantation isolated AlGaN/GaN MIS-HEMTs.

  1. Microleakage of adhesive restorative materials.

    PubMed

    Gladys, S; Van Meerbeek, B; Lambrechts, P; Vanherle, G

    2001-06-01

    To compare the marginal sealing ability of two conventional and one polyacid-modified resin-based composite, and two conventional and three resin-modified glass-ionomers in conventional cylindrical box cavities following a silver-staining microleakage evaluation method. In 80 freshly extracted and caries-free human third molars, three standardized cylindrical butt-joint cavities were prepared: the first cavity in coronal enamel, the second at the cemento-enamel junction (CEJ) and the third completely in root cementum. A control group of 10 additional teeth was chosen. After the cavities were restored randomly using the eight restorative materials tested, the specimens were first stored in distilled water at 37 degrees C for 7 days and then thermocycled (500 cycles). Thereafter, the specimens were centrifuged for 10 min in plastic bottles containing 50 wt% silver nitrate aqueous solution. The degree of microleakage was recorded at four different depths along the restoration margins using an optical stereomicroscope equipped with a measuring gauge. None of the tested systems prevented microleakage completely, but the extent of leakage decreased towards the bottom of the restorations. The resin-modified glass-ionomers performed better than the conventional resin-based composites and conventional glass-ionomers. Distinct leakage patterns were recorded among all materials investigated. Complete marginal sealing could still not be reached with the new adhesive restorative materials.

  2. Application of distributed optical fiber sensing technologies to the monitoring of leakage and abnormal disturbance of oil pipeline

    NASA Astrophysics Data System (ADS)

    Yang, Xiaojun; Zhu, Xiaofei; Deng, Chi; Li, Junyi; Liu, Cheng; Yu, Wenpeng; Luo, Hui

    2017-10-01

    To improve the level of management and monitoring of leakage and abnormal disturbance of long distance oil pipeline, the distributed optical fiber temperature and vibration sensing system is employed to test the feasibility for the healthy monitoring of a domestic oil pipeline. The simulating leakage and abnormal disturbance affairs of oil pipeline are performed in the experiment. It is demonstrated that the leakage and abnormal disturbance affairs of oil pipeline can be monitored and located accurately with the distributed optical fiber sensing system, which exhibits good performance in the sensitivity, reliability, operation and maintenance etc., and shows good market application prospect.

  3. Transmission seal development

    NASA Technical Reports Server (NTRS)

    Brien, M.

    1977-01-01

    An experimental evaluation was performed on a high-speed (72.9 m/s, 14,349 ft/min) transmission seal of the synergistic type. During testing of the seal, oil leakage occurred at positive bearing cavity pressures. Modifications were made in an attempt to eliminate the leakage but none were completely successful. Leakage appears to be the result of questionable positioning of the sealing elements resulting in inadequate shaft contact by the oil side sealing element. This condition may be related to the nonsymmetrical shape of the elastomeric retainer and to dimensional changes caused by swelling of the elastomeric retainer from exposure to the sealed fluid. Indications of a speed dependent leakage characteristic were also observed.

  4. Cold-air performance of a tip turbine designed to drive a lift fan. 3: Effect of simulated fan leakage on turbine performance

    NASA Technical Reports Server (NTRS)

    Haas, J. E.; Kofskey, M. G.; Hotz, G. M.; Futral, S. M., Jr.

    1978-01-01

    Performance data were obtained experimentally for a 0.4 linear scale version of the LF460 lift fan turbine for a range of scroll inlet total to diffuser exit static pressure ratios at design equivalent speed with simulated fan leakage air. Tests were conducted for full and partial admission operation with three separate combinations of rotor inlet and rotor exit leakage air. Data were compared to the results obtained from previous investigations in which no leakage air was present. Results are presented in terms of mass flow, torque, and efficiency.

  5. Using side-opening injection cannulas to prevent cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures, does it really work?

    PubMed

    Li, Jigang; Li, Tao; Ma, Qiuhong; Li, Jianmin

    2017-09-01

    Percutaneous vertebroplasty has been widely applied in the treatment of osteoporotic vertebral compression fractures over the past two decades. However as one of the major complications, the rate of cement leakage seems not to be decreased significantly. In this study, the rate of cement leakage was compared between two groups using two different cement injection cannulas. The purpose was to determine the efficacy of side-opening cannula on preventing cement leakage in vertebroplasty for the treatment of osteoporotic vertebral compression fractures. A retrospective study was conducted from January 2013 to December 2015. Totally 225 patients who received bilateral vertebroplasty due to osteoporotic vertebral compression fractures were included in the study. The patients were divided into test group who received vertebroplasty with side-opening cannulas and control group who received vertebroplasty with front-opening cannulas. The patients' medical records were reviewed to determine the bone marrow density, preoperative vertebral compression ratio, preoperative and postoperative VAS, operation time, volume of injected bone cement, rate of cement leakage. Post-operative X-rays and CT scans were utilized to assess the degree of Cement leakage. Comparisons between groups and clinical results on VAS in each group were analyzed with appropriate test. All the patients were performed successfully without symptomatic complications. The back pain was significantly relieved after operation in both groups (P < 0.05). At 6 days and 6 months follow-up, there was no significant difference in the mean VAS score between the two groups (P > 0.05). The rate of cement leakage in the test group was significantly lower than that in the control group (P < 0.05). Percutaneous vertebroplasty with side-opening cannula is a safe and effective minimally invasive method in the treatment of osteoporotic vertebral compression fractures, the rate of cement leakage can be significantly reduced by redirecting the cement flow. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  6. Estimation of Leakage Potential of Selected Sites in Interstate and Tri-State Canals Using Geostatistical Analysis of Selected Capacitively Coupled Resistivity Profiles, Western Nebraska, 2004

    USGS Publications Warehouse

    Vrabel, Joseph; Teeple, Andrew; Kress, Wade H.

    2009-01-01

    With increasing demands for reliable water supplies and availability estimates, groundwater flow models often are developed to enhance understanding of surface-water and groundwater systems. Specific hydraulic variables must be known or calibrated for the groundwater-flow model to accurately simulate current or future conditions. Surface geophysical surveys, along with selected test-hole information, can provide an integrated framework for quantifying hydrogeologic conditions within a defined area. In 2004, the U.S. Geological Survey, in cooperation with the North Platte Natural Resources District, performed a surface geophysical survey using a capacitively coupled resistivity technique to map the lithology within the top 8 meters of the near-surface for 110 kilometers of the Interstate and Tri-State Canals in western Nebraska and eastern Wyoming. Assuming that leakage between the surface-water and groundwater systems is affected primarily by the sediment directly underlying the canal bed, leakage potential was estimated from the simple vertical mean of inverse-model resistivity values for depth levels with geometrically increasing layer thickness with depth which resulted in mean-resistivity values biased towards the surface. This method generally produced reliable results, but an improved analysis method was needed to account for situations where confining units, composed of less permeable material, underlie units with greater permeability. In this report, prepared by the U.S. Geological Survey in cooperation with the North Platte Natural Resources District, the authors use geostatistical analysis to develop the minimum-unadjusted method to compute a relative leakage potential based on the minimum resistivity value in a vertical column of the resistivity model. The minimum-unadjusted method considers the effects of homogeneous confining units. The minimum-adjusted method also is developed to incorporate the effect of local lithologic heterogeneity on water transmission. Seven sites with differing geologic contexts were selected following review of the capacitively coupled resistivity data collected in 2004. A reevaluation of these sites using the mean, minimum-unadjusted, and minimum-adjusted methods was performed to compare the different approaches for estimating leakage potential. Five of the seven sites contained underlying confining units, for which the minimum-unadjusted and minimum-adjusted methods accounted for the confining-unit effect. Estimates of overall leakage potential were lower for the minimum-unadjusted and minimum-adjusted methods than those estimated by the mean method. For most sites, the local heterogeneity adjustment procedure of the minimum-adjusted method resulted in slightly larger overall leakage-potential estimates. In contrast to the mean method, the two minimum-based methods allowed the least permeable areas to control the overall vertical permeability of the subsurface. The minimum-adjusted method refined leakage-potential estimation by additionally including local lithologic heterogeneity effects.

  7. An objective comparison of leakage between commonly used earplugs.

    PubMed

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P < .05). At 30 seconds, the custom molded, Mack's and Doc's plugs all showed significantly less leakage when compared with the cotton ball coated with petroleum jelly (P < .05). At 60, 120, and 180 seconds, Mack's, Doc's, and the cotton plugs all showed significantly less leakage compared with the customized plug (P < .05). At 120 and 180 seconds, Mack's plugs had significant less leakage than the cotton plug (P < .05). Among the types of plugs, the molded variety (Mack's) showed the least volume and lowest leakage rate (f(4,45) = 94 [P < .001]). In addition, Doc's and cotton balls coated with petroleum jelly were more effective than the customized earplugs. If the clinician feels that middle ear and external canal water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Further Characterization of an Active Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

  9. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea.

    PubMed

    Aydin, K; Guven, K; Sencer, S; Jinkins, J R; Minareci, O

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair.

  10. Experimental investigation of leak detection using mobile distributed monitoring system

    NASA Astrophysics Data System (ADS)

    Chen, Jiang; Zheng, Junli; Xiong, Feng; Ge, Qi; Yan, Qixiang; Cheng, Fei

    2018-01-01

    The leak detection of rockfill dams is currently hindered by spatial and temporal randomness and wide monitoring range. The spatial resolution of fiber Bragg grating (FBG) temperature sensing technology is related to the distance between measuring points. As a result, the number of measuring points should be increased to ensure that the precise location of the leak is detected. However, this leads to a higher monitoring cost. Consequently, it is difficult to promote and apply this technology to effectively monitor rockfill dam leakage. In this paper, a practical mobile distributed monitoring system with dual-tubes is used by combining the FBG sensing system and hydrothermal cycling system. This dual-tube structure is composed of an outer polyethylene of raised temperature resistance heating pipe, an inner polytetrafluoroethylene tube, and a FBG sensor string, among which, the FBG sensor string can be dragged freely in the internal tube to change the position of the measuring points and improve the spatial resolution. In order to test the effectiveness of the system, the large-scale model test of concentrated leakage in 13 working conditions is carried out by identifying the location, quantity, and leakage rate of leakage passage. Based on Newton’s law of cooling, the leakage state is identified using the seepage identification index ζ v that was confirmed according to the cooling curve. Results suggested that the monitoring system shows high sensitivity and can improve the spatial resolution with limited measuring points, and thus better locate the leakage area. In addition, the seepage identification index ζ v correlated well with the leakage rate qualitatively.

  11. Case Study of Envelope Sealing in Existing Multiunit Structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Podorson, D.

    2012-10-01

    Envelope air sealing was included in the retrofit of a 244 unit low-rise multifamily housing complex in Durham, N.C. Pre- and post-retrofit enclosure leakage tests were conducted on 51 units and detailed diagnostics were performed on 16. On average, total leakage was reduced by nearly half, from 19.7 ACH50 to 9.4 ACH50. Costs for air sealing were $0.31 per square foot of conditioned floor area, lower than estimates found in the National Residential Efficiency Measures Database (NREMD) and other sources, perhaps due in part to the large-scale production nature of the project. Modeling with BEopt software -- using an estimatemore » of 85% of the envelope air leakage going to the outside (based on guarded tests performed at the site) -- calculated a space conditioning energy cost savings of 15% to 21% due to the air sealing retrofit. Important air leakage locations identified included plumbing and electrical penetrations, dropped ceilings/soffits, windows, ducts and wall-to-floor intersections. Previous repair activity had created significant leakage locations as well. Specifications and a pictorial guide were developed for contractors performing the work.« less

  12. Development of dual field magnetic flux leakage (MFL) inspection technology to detect mechanical damage.

    DOT National Transportation Integrated Search

    2013-03-01

    This report details the development and testing of a dual magnetization in-line inspection (ILI) : tool for detecting mechanical damage in operating pipelines, including the first field trials of a : fully operational dual-field magnetic flux leakage...

  13. Reactive Membrane Barriers for Containment of Subsurface Contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    William A. Arnold; Edward L. Cussler

    2007-02-26

    The overall goal of this project was to develop reactive membrane barriers--a new and flexible technique to contain and stabilize subsurface contaminants. Polymer membranes will leak once a contaminant is able to diffuse through the membrane. By incorporating a reactive material in the polymer, however, the contaminant is degraded or immobilized within the membrane. These processes increase the time for contaminants to breakthrough the barrier (i.e. the lag time) and can dramatically extend barrier lifetimes. In this work, reactive barrier membranes containing zero-valent iron (Fe{sup 0}) or crystalline silicotitanate (CST) were developed to prevent the migration of chlorinated solvents andmore » cesium-137, respectively. These studies were complemented by the development of models quantifying the leakage/kill time of reactive membranes and describing the behavior of products produced via the reactions within the membranes. First, poly(vinyl alcohol) (PVA) membranes containing Fe{sup 0} and CST were prepared and tested. Although PVA is not useful in practical applications, it allows experiments to be performed rapidly and the results to be compared to theory. For copper ions (Cu{sup 2+}) and carbon tetrachloride, the barrier was effective, increasing the time to breakthrough over 300 times. Even better performance was expected, and the percentage of the iron used in the reaction with the contaminants was determined. For cesium, the CST laden membranes increased lag times more than 30 times, and performed better than theoretical predictions. A modified theory was developed for ion exchangers in reactive membranes to explain this result. With the PVA membranes, the effect of a groundwater matrix on barrier performance was tested. Using Hanford groundwater, the performance of Fe{sup 0} barriers decreased compared to solutions containing a pH buffer and high levels of chloride (both of which promote iron reactivity). For the CST bearing membrane, performance improved by a factor of three when groundwater was used in place of deionized water. The performance of high density polyethylene (HDPE) membranes containing Fe{sup 0} was then evaluating using carbon tetrachloride as the target contaminant. Only with a hydrophilic additive (glycerol), was the iron able to extend lag times. Lag times were increased by a factor of 15, but only 2-3% of the iron was used, likely due to formation of oxide precipitates on the iron surface, which slowed the reaction. With thicker membranes and lower carbon tetrachloride concentrations, it is expected that performance will improve. Previous models for reactive membranes were also extended. The lag time is a measurement of when the barrier is breached, but contaminants do slowly leak through prior to the lag time. Thus, two parameters, the leakage and the kill time, were developed to determine when a certain amount of pollutant has escaped (the kill time) or when a given exposure (concentration x time) occurs (the leakage). Finally, a model was developed to explain the behavior of mobile reaction products in reactive barrier membranes. Although the goal of the technology is to avoid such products, it is important to be able to predict how these products will behave. Interestingly, calculations show that for any mobile reaction products, one half of the mass will diffuse into the containment area and one half will escape, assuming that the volumes of the containment area and the surrounding environment are much larger than the barrier membrane. These parameters/models will aid in the effective design of barrier membranes.« less

  14. INSTRUMENTATION AND TECHNIQUES. A SELF-CONTAINED, REGULATED, BURST-FIRING CONSTANT-CURRENT AC SHOCK GENERATOR

    EPA Science Inventory

    A line- and load-regulated constant-current ac shock generator has been designed for animal behavior experiments. The self-contained unit has four operating modes, amplitude adjustment, and a leakage current detection circuit. A unique feature of this generator is that the good l...

  15. Robustness of Modeling of Out-of-Service Gas Mechanical Face Seal

    NASA Technical Reports Server (NTRS)

    Green, Itzhak

    2007-01-01

    Gas lubricated mechanical face seal are ubiquitous in many high performance applications such as compressors and gas turbines. The literature contains various analyses of seals having orderly face patterns (radial taper, waves, spiral grooves, etc.). These are useful for design purposes and for performance predictions. However, seals returning from service (or from testing) inevitably contain wear tracks and warped faces that depart from the aforementioned orderly patterns. Questions then arise as to the heat generated at the interface, leakage rates, axial displacement and tilts, minimum film thickness, contact forces, etc. This work describes an analysis of seals that may inherit any (i.e., random) face pattern. A comprehensive computer code is developed, based upon the Newton- Raphson method, which solves for the equilibrium of the axial force and tilting moments that are generated by asperity contact and fluid film effects. A contact mechanics model is incorporated along with a finite volume method that solves the compressible Reynolds equation. Results are presented for a production seal that has sustained a testing cycle.

  16. [Nursing Experience With a Patient With Gastrostomy Leakage Resulting in Moisture-Associated Skin Damage].

    PubMed

    Hsu, Mei-Yu; Hsu, Hsiao-Hui; Lyu, Ji-Yan

    2016-10-01

    Leakage is a common complication of gastrostomy. Exposure of the skin surrounding the gastrostomy tube to moisture or chemical irritants may cause moisture-associated skin damage (MASD) and seriously affect the patient's quality of life. This case study describes a nursing experience with gastrostomy leakage that resulted in MASD. An assessment conducted from July 29, 2015 to August 20, 2015 revealed that heavy gastronomy leakage had caused extensive skin erosion, ulceration, hyperplasia, and superficial infection. Simultaneously, the patient was required to conduct complex stoma care, which resulted in physical and psychological exhaustion. Changes in traditional tube and wound care were discussed on multiple occasions with an interdisciplinary healthcare team. Based on the evidence-based literature, we provide gastrostomy and MASD management strategies. Through team collaboration, we prevented gastric contents from contacting the patient's skin directly, improved patient comfort, controlled effluent and skin infections, maintained fluid and electrolyte balances, and acce-lerated the healing of the damaged skin. We recommend that healthcare professionals caring for patients with gastrostomy leakage be provided with early skin protection programs to learn the standard methods for identifying and correcting leakage factors, containing effluent, and adequately stabilizing the gastrostomy tube in order to reduce the impact on the patient's quality of life. In addition, patient education on tube and skin care should be provided to prevent the reoccurrence of complications.

  17. Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems

    PubMed Central

    H, Farhadpour; F, Sharafeddin; Sc, Akbarian; B, Azarian

    2016-01-01

    Statement of Problem: Hemostatic agents may affect the micro-leakage of different adhesive systems. Also, chlorhexidine has shown positive effects on micro-leakage. However, their interaction effect has not been reported yet. Objectives: To evaluate the effect of contamination with a hemostatic agent on micro-leakage of total- and self-etching adhesive systems and the effect of chlorhexidine application after the removal of the hemostatic agent. Materials and Methods: Standardized Class V cavity was prepared on each of the sixty caries free premolars at the cemento-enamel junction, with the occlusal margin located in enamel and the gingival margin in dentin. Then, the specimens were randomly divided into 6 groups (n = 10) according to hemostatic agent (H) contamination, chlorhexidine (CHX) application, and the type of adhesive systems (Adper Single Bond and Clearfil SE Bond) used. After filling the cavities with resin composite, the root apices were sealed with utility wax. Furthermore, all the surfaces, except for the restorations and 1mm from the margins, were covered with two layers of nail varnish. The teeth were immersed in a 0.5% basic fuschin dye for 24 hours, rinsed, blot-dried and sectioned longitudinally through the center of the restorations bucco- lingualy. The sections were examined using a stereomicroscope and the extension of dye penetration was analyzed according to a non-parametric scale from 0 to 3. Statistical analysis was performed using Kruskal-Wallis test and Mann-Whitney U-test. Results: While ASB group showed no micro-leakage in enamel, none of the groups showed complete elimination of micro-leakage from the dentin. Regarding micro-leakage at enamel, and dentin margins, there was no significant difference between groups 1 and 2, 1 and 3, and 2 and 3 (p > 0.05). A significantly lower micro-leakage at the enamel and dentin margins was observed in group 3, compared to group 6. No significant difference was observed between groups 4 and 5 in enamel (p = 0.35) and dentin (p = 0.34). Group 6 showed significantly higher micro-leakage, compared to group 4 and 5 (p < 0.05). Conclusions: Hemostatic agent contamination had no significant effect on micro-leakage of total- and self-etching adhesive systems. Application of chlorhexidine after the removal of hemostatic agent increased micro-leakage in self-etching adhesives but did not affect when total-etching was used. PMID:28959756

  18. Investigative techniques used to locate the liquid hydrogen leakage on the Space Shuttle Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hammock, William R., Jr.; Cota, Phillip E., Jr.; Rosenbaum, Bernard J.; Barrett, Michael J.

    1991-01-01

    Standard leak detection methods at ambient temperature have been developed in order to prevent excessive leakage from the Space Shuttle liquid oxygen and liquid hydrogen Main Propulsion System. Unacceptable hydrogen leakage was encountered on the Columbia and Atlantis flight vehicles in the summer of 1990 after the standard leak check requirements had been satisfied. The leakage was only detectable when the fuel system was exposed to subcooled liquid hydrogen during External Tank loading operations. Special instrumentation and analytical tools were utilized during a series of propellant tanking tests in order to identify the sources of the hydrogen leakage. After the leaks were located and corrected, the physical characteristics of the leak sources were analyzed in an effort to understand how the discrepancies were introduced and why the leakage had evaded the standard leak detection methods. As a result of the post-leak analysis, corrective actions and leak detection improvements have been implemented in order to preclude a similar incident.

  19. Sealing ability of MTA, CPM, and MBPc as root-end filling materials: a bacterial leakage study.

    PubMed

    Medeiros, Paulo Leal; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Torres, Sérgio Aparecido; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Marciano, Marina Angélica

    2016-04-01

    Objectives To evaluate the sealing ability of three root-end filling materials (white MTA, CPM, and MBPc) using an Enterococcus faecalis leakage model. Material and Methods Seventy single-root extracted human teeth were instrumented and root-ends were resected to prepare 3 mm depth cavities. Root-end preparations were filled with white MTA, CPM, and MBPc cements. Enterococcus faecalis was coronally introduced and the apical portion was immersed in BHI culture medium with phenol red indicator. The bacterial leakage was monitored every 24 h for 4 weeks. The statistical analysis was performed using the Wilcoxon-Gehan test (p<0.05). Results All cements showed bacterial leakage after 24 hours, except for the negative control group. The MBPc showed significantly less bacterial leakage compared with the MTA group (p<0.05). No significant differences were found between the CPM and the other groups. Conclusions The epoxy resin-based cement MBPc had lower bacterial leakage compared with the calcium silicate-based cements MTA and CPM.

  20. A comparison of experimental and theoretical results for leakage, pressure distribution, and rotordynamic coefficients for annular gas seals

    NASA Technical Reports Server (NTRS)

    Nicks, C. O.; Childs, D. W.

    1984-01-01

    The importance of seal behavior in rotordynamics is discussed and current annular seal theory is reviewed. A Nelson's analytical-computational method for determining rotordynamic coefficients for this type of compressible-flow seal is outlined. Various means for the experimental identification of the dynamic coefficients are given, and the method employed at the Texas A and M University (TAMU) test facility is explained. The TAMU test apparatus is described, and the test procedures are discussed. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and rotordynamic coefficients for a smooth and a honeycomb constant-clearance seal are presented and compared to theoretical results from Nelson's analysis. The results for both seals show little sensitivity to the running speed over the test range. Agreement between test results and theory for leakage through the seal is satisfactory. Test results for direct stiffness show a greater sensitivity to fluid pre-rotation than predicted. Results also indicate that the deliberately roughened surface of the honeycomb seal provides improved stability versus the smooth seal.

  1. Indocyanine green angiographic evidence of choroiditis in scleroderma.

    PubMed

    Abdellatief, Amro; Balasubramaniam, Saranya C; Grube, Thomas J; Gonzalez Santiago, Tania M; Osborn, Thomas G; Pulido, Jose S

    2015-01-01

    The purpose of this case report was to demonstrate evidence of indocyanine green angiography leakage consistent with choroiditis in a patient with scleroderma. In this case report, the patient underwent a variety of tests and examinations, including systemic evaluation, full ocular examination, skin biopsy, indocyanine green, and fluorescein angiography testing. A 52-year-old man had blurred vision centrally in both eyes. Vision was 20/25 and 20/20. Posterior examination showed cotton-wool spots in both eyes. The patient met European League against Rheumatism (EULAR) criteria for scleroderma. Fluorescein angiography confirmed the presence of leakage from the retinal vessels. More importantly, indocyanine green angiography revealed choroidal vessel leakage in both eyes. This provided evidence of choroiditis before vessel obliteration. Previous studies have shown evidence of choriocapillaris obliteration. Choroidal vessel leakage, however, has not been reported in patients with scleroderma. The results of this case demonstrate the usefulness of indocyanine green angiography in detecting the presence of choroiditis in scleroderma.

  2. Control design based on dead-zone and leakage adaptive laws for artificial swarm mechanical systems

    NASA Astrophysics Data System (ADS)

    Zhao, Xiaomin; Chen, Y. H.; Zhao, Han

    2017-05-01

    We consider the control design of artificial swarm systems with emphasis on four characteristics. First, the agent is made of mechanical components. As a result, the motion of each agent is subject to physical laws that govern mechanical systems. Second, both nonlinearity and uncertainty of the mechanical system are taken into consideration. Third, the ideal agent kinematic performance is treated as a desired d'Alembert constraint. This in turn suggests a creative way of embedding the constraint into the control design. Fourth, two types of adaptive robust control schemes are designed. They both contain leakage and dead-zone. However, one design suggests a trade-off between the amount of leakage and the size of dead-zone, in exchange for a simplified dead-zone structure.

  3. Fluid leakage through fractures in an impervious caprock embedded between two geologic aquifers

    NASA Astrophysics Data System (ADS)

    Selvadurai, A. P. S.

    2012-06-01

    The paper develops an analytical result for the flow through a single fracture under a hydraulic gradient between the two aquifer regions and takes into account permeability characteristics of all components of the system. Non-dimensional results are presented to illustrate the influence of the permeability mis-match between the two geologic formations and the permeability and geometry of the fracture on the flow rate through the fracture. The analytical result is then used to develop additional results for leakage through a swarm of vertically aligned hydraulically non-interacting fractures and a damaged region containing a densely spaced array of vertically aligned fractures and worm hole type features in the caprock. The work presents a convenient result for the estimation of leakage from storage formations in geoenvironmental applications.

  4. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    PubMed

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  5. Theory and Application of Magnetic Flux Leakage Pipeline Detection

    PubMed Central

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-01-01

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted. PMID:26690435

  6. Aerospace Payloads Leak Test Methodology

    NASA Technical Reports Server (NTRS)

    Lvovsky, Oleg; Grayson, Cynthia M.

    2010-01-01

    Pressurized and sealed aerospace payloads can leak on orbit. When dealing with toxic or hazardous materials, requirements for fluid and gas leakage rates have to be properly established, and most importantly, reliably verified using the best Nondestructive Test (NDT) method available. Such verification can be implemented through application of various leak test methods that will be the subject of this paper, with a purpose to show what approach to payload leakage rate requirement verification is taken by the National Aeronautics and Space Administration (NASA). The scope of this paper will be mostly a detailed description of 14 leak test methods recommended.

  7. Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing.

    PubMed

    Wardrip, Nathaniel C; Arnusch, Christopher J

    2016-02-13

    Minimization and management of membrane fouling is a formidable challenge in diverse industrial processes and other practices that utilize membrane technology. Understanding the fouling process could lead to optimization and higher efficiency of membrane based filtration. Here we show the design and fabrication of an automated three-dimensionally (3-D) printed microfluidic cross-flow filtration system that can test up to 4 membranes in parallel. The microfluidic cells were printed using multi-material photopolymer 3-D printing technology, which used a transparent hard polymer for the microfluidic cell body and incorporated a thin rubber-like polymer layer, which prevents leakages during operation. The performance of ultrafiltration (UF), and nanofiltration (NF) membranes were tested and membrane fouling could be observed with a model foulant bovine serum albumin (BSA). Feed solutions containing BSA showed flux decline of the membrane. This protocol may be extended to measure fouling or biofouling with many other organic, inorganic or microbial containing solutions. The microfluidic design is especially advantageous for testing materials that are costly or only available in small quantities, for example polysaccharides, proteins, or lipids due to the small surface area of the membrane being tested. This modular system may also be easily expanded for high throughput testing of membranes.

  8. Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing

    PubMed Central

    Wardrip, Nathaniel C.; Arnusch, Christopher J.

    2016-01-01

    Minimization and management of membrane fouling is a formidable challenge in diverse industrial processes and other practices that utilize membrane technology. Understanding the fouling process could lead to optimization and higher efficiency of membrane based filtration. Here we show the design and fabrication of an automated three-dimensionally (3-D) printed microfluidic cross-flow filtration system that can test up to 4 membranes in parallel. The microfluidic cells were printed using multi-material photopolymer 3-D printing technology, which used a transparent hard polymer for the microfluidic cell body and incorporated a thin rubber-like polymer layer, which prevents leakages during operation. The performance of ultrafiltration (UF), and nanofiltration (NF) membranes were tested and membrane fouling could be observed with a model foulant bovine serum albumin (BSA). Feed solutions containing BSA showed flux decline of the membrane. This protocol may be extended to measure fouling or biofouling with many other organic, inorganic or microbial containing solutions. The microfluidic design is especially advantageous for testing materials that are costly or only available in small quantities, for example polysaccharides, proteins, or lipids due to the small surface area of the membrane being tested. This modular system may also be easily expanded for high throughput testing of membranes.  PMID:26968008

  9. GPR-Based Water Leak Models in Water Distribution Systems

    PubMed Central

    Ayala-Cabrera, David; Herrera, Manuel; Izquierdo, Joaquín; Ocaña-Levario, Silvia J.; Pérez-García, Rafael

    2013-01-01

    This paper addresses the problem of leakage in water distribution systems through the use of ground penetrating radar (GPR) as a nondestructive method. Laboratory tests are performed to extract features of water leakage from the obtained GPR images. Moreover, a test in a real-world urban system under real conditions is performed. Feature extraction is performed by interpreting GPR images with the support of a pre-processing methodology based on an appropriate combination of statistical methods and multi-agent systems. The results of these tests are presented, interpreted, analyzed and discussed in this paper.

  10. Bacterial leakage through temporary fillings in core buildup composite material - an in vitro study.

    PubMed

    Rechenberg, Dan-Krister; Schriber, Martina; Attin, Thomas

    2012-08-01

    To evaluate the ability of the provisional filling material Cavit-W alone or in combination with different restorative materials to prevent bacterial leakage through simulated access cavities in a resin buildup material. LuxaCore resin cylinders were subdivided into 4 experimental groups (n = 30), plus a positive (n = 5) and a negative (n = 30) control group. One bore hole was drilled through each cylinder, except those in the negative control group (G1). The holes were filled with Cavit-W (G2), Cavit-W and Ketac-Molar (glassionomer cement, G3), Cavit-W and LuxaCore bonded with LuxaBond (G4), Cavit-W and LuxaCore (G5), or left empty (G6). Specimens were mounted in a two-chamber leakage setup. The upper chamber was inoculated with E. faecalis. An enterococci-selective broth was used in the lower chamber. Leakage was assessed for 60 days and compared using Fisher's exact test (α < 0.05) corrected for multiple testing. Bacteria penetrated specimens in the positive control group within 24 h. All specimens in the negative control group resisted bacterial leakage for 60 days. Twenty-seven specimens in G2, 26 in G3, and 16 specimens in G5 showed bacterial leakage by the end of the experiment. G4 prevented bacterial penetration completely. The statistical comparison revealed significant differences between G4 and all other experimental groups. Under the current conditions, Cavit-W alone or combined with a glass-ionomer cement did not prevent bacterial leakage through a resin buildup material for two months. In contrast, covering Cavit-W with a bonded resin material resulted in a bacteria-tight seal for two months.

  11. Closed-Suction Drainage and Cerebrospinal Fluid Leakage Following Microvascular Decompression : A Retrospective Comparison Study

    PubMed Central

    Kim, Young-Hoon; Kim, Chae-Yong; Oh, Chang Wan

    2013-01-01

    Objective We performed this study to investigate whether the use of closed-suction drainage following microvascular decompression (MVD) causes cerebrospinal fluid (CSF) leakage. Methods Between 2004 and 2011, a total of 157 patients with neurovascular compression were treated with MVD. MVD was performed for hemifacial spasm in 150 (95.5%) cases and for trigeminal neuralgia in 7 (4.5%) cases. The mean age of the patients was 49.8±9.6 years (range, 20-69). Dural substitutes were used in 44 (28.0%) patients. Ninety-two patients (58.6%) were underwent a 4-5 cm craniotomy using drainage (drainage group), and 65 (41.4%) did a small 2-2.5 cm retromastoid craniectomy without closed-suction drainage (no-drainage group). Results Eleven (7.0%) patients experienced CSF leakage following MVD based on the criteria of this study; all of these patients were in the drainage group. In the unadjusted analyses, the incidence of CSF leakage was significantly related with the use of closed-suction drainage following MVD (12.0% in the drainage group vs. 0% in the no-drainage group, respectively; p=0.003; Fisher's exact test). Those who received dural substitutes and the elderly (cut-off value=60 years) exhibited a tendency to develop CSF leakage (p=0.075 and p=0.090, respectively; Fisher's exact test). In the multivariate analysis, only the use of closed-suction drainage was significantly and independently associated with the development of CSF leakage following MVD (odds ratio=9.900; 95% confidence interval, 1.418 to infinity; p=0.017). Conclusion The use of closed-suction drainage following MVD appears to be related to the development of CSF leakage. PMID:24175025

  12. Leakage of Microbial Endotoxin through the Implant-Abutment Interface in Oral Implants: An In Vitro Study.

    PubMed

    Garrana, Rhoodie; Mohangi, Govindrau; Malo, Paulo; Nobre, Miguel

    2016-01-01

    Background . Endotoxin initiates osteoclastic activity resulting in bone loss. Endotoxin leakage through implant abutment connections negatively influences peri-implant bone levels. Objectives . (i) To determine if endotoxin can traverse different implant-abutment connection (IAC) designs; (ii) to quantify the amount of endotoxins traversing the IAC; (iii) to compare the in vitro comportments of different IACs. Materials and Methods . Twenty-seven IACs were inoculated with E. coli endotoxin. Six of the twenty-seven IACs were external connections from one system (Southern Implants) and the remaining twenty-one IACs were made up of seven internal IAC types from four different implant companies (Straumann, Ankylos, and Neodent, Southern Implants). Results . Of the 27 IACs tested, all 6 external IACs leaked measurable amounts of endotoxin. Of the remaining 21 internal IACs, 9 IACs did not show measurable leakage whilst the remaining 12 IACs leaked varying amounts. The mean log endotoxin level was significantly higher for the external compared to internal types ( p = 0.015). Conclusion . Within the parameters of this study, we can conclude that endotoxin leakage is dependent on the design of the IAC. Straumann Synocta, Straumann Cross-fit, and Ankylos displayed the best performances of all IACs tested with undetectable leakage after 7 days. Each of these IACs incorporated a morse-like component in their design. Speculation still exists over the impact of IAC endotoxin leakage on peri-implant tissues in vivo; hence, further investigations are required to further explore this.

  13. Methodology for the in vitro evaluation of the delivery efficiency from valved holding chambers with facemasks.

    PubMed

    Xu, Zhen; Hsu, Wenchi; von Hollen, Dirk; Viswanath, Ashwin; Nikander, Kurt; Dalby, Richard

    2014-08-01

    In vitro performance studies of valved holding chamber (VHC)-facemask systems are a cost-effective means of circumventing potentially confounding clinical variables. This article reports results of an in vitro investigation into VHC-facemask performance, using three age-specific soft anatomical model (SAM) faces, under clinically relevant conditions. A potentially standardized method was developed to assess VHC-facemask seal leakage, and evaluate the in vitro delivery efficiency of conventional and antistatic VHC-facemask systems. A custom-built test rig and VHC cradles were used to position the VHC-facemask systems against the SAM faces, with a constant, reproducible force. A standardized simulated pediatric breathing pattern (tidal volume = 155 mL; inhalation:exhalation ratio = 40:60; 25 breaths/min) was utilized. Percent facemask seal leakage, percent delivered dose, and the effect of different numbers of simulated breaths (2 to 8) were investigated. Of the VHC-facemask systems tested, the OptiChamber Diamond VHC with LiteTouch facemask (Diamond) system had the lowest percent seal leakage with each SAM face. Percent seal leakage from the other VHC-facemask systems was similar with SAM0 and SAM2 faces; the AeroChamber Plus Z-Stat VHC with ComfortSeal facemask (AC Z-Stat) system had a substantially greater percent seal leakage with the SAM1 face. Regardless of the number of simulated breaths, the Diamond system delivered the greatest mean percent delivered dose, with the lowest coefficient of variation, with each SAM face. Percent delivered dose did not correlate well with seal leakage, particularly for VHC-facemask systems with high seal leakage. The electrostatic properties of the VHCs appeared to influence drug delivery. This study describes a potentially standardized method for the evaluation of VHC-facemask systems. Use of this method enabled a comprehensive investigation into the influence of clinically relevant variables, including age-specific facial anatomy, number of simulated breaths, and seal leakage, on the delivery efficiency of several commercially available VHC-facemask systems.

  14. Magnetic Resonance Imaging-Based Assessment of Gadolinium-Conjugated Diethylenetriamine Penta-Acetic Acid Test-Infusion in Detecting Dysfunction of Convection-Enhanced Delivery Catheters.

    PubMed

    van Putten, Erik H P; Wembacher-Schröder, Eva; Smits, Marion; Dirven, Clemens M F

    2016-05-01

    In a phase 1 trial conducted at our institute, convection-enhanced delivery (CED) was used to administrate the Delta-24-RGD adenovirus in patients with a recurrent glioblastoma multiforme. Infusion of the virus was preceded by a gadolinium-conjugated diethylenetriamine penta-acetic acid (Gd-DTPA) test-infusion. In the present study, we analyzed the results of Gd-DTPA test infusion through 50 catheters. Thirteen adults with a recurrent glioblastoma multiforme were enrolled in a larger phase 1 multicenter, dose-finding study, in which a conditionally replication-competent adenovirus was administered by CED. Up to 4 infusion catheters per patient were placed intra- and/or peritumorally. Before infusion of the virus, a Gd-DTPA infusion was performed for 6 hours, directly followed by a MRI scan. The MRIs were evaluated for catheter position, Gd-DTPA distribution outcome, and contrast leakage. Leakage of Gd-DTPA into the cerebrospinal fluid was detected in 17 of the 50 catheters (34%). Sulcus crossing was the most frequent cause of leakage. In 8 cases, leakage could only be detected on the fluid-attenuated inversion recovery sequence. Nonleaking catheters showed a significantly larger Gd-DTPA distribution fraction (volume of distribution/volume of infusion) than leaking catheters (P = 0.009). A significantly lower volume of distribution/volume of infusion was observed in intratumoral catheters, compared with peritumoral catheters (P = 0.004). Gd-DTPA test infusion did not result in significant changes in Karnofsky Performance Score and Neurological Status. Pre-CED treatment infusion of Gd-DTPA is an adequate and safe method to identify dysfunctional catheters. The use of an optimized drug delivery catheter is necessary to reduce leakage and improve the efficacy of intracerebral drug infusion. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. 75 FR 29699 - Total Inward Leakage Requirements for Respirators

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ... or other half-mask respirator inward leakage measurement, and offer any additional comments on the..., facsimile (412) 386-4089, e-mail [email protected] . SUPPLEMENTARY INFORMATION: I. Background The Department of... order to conduct tests and prepare responses. On April 20, 2010, NIOSH responded by reopening the docket...

  16. The comparison of microbial leakage in roots filled with resilon and gutta-percha: An in vitro study.

    PubMed

    Shashidhar, C; Shivanna, Vasundhara; Shivamurthy, Gb; Shashidhar, Jyothi

    2011-01-01

    The objective of this study was to compare bacterial leakage using streptococcus mutans through gutta-percha and a thermoplastic synthetic polymer based root canal filling material (Resilon) using two filling techniques. A total of 90 single-rooted extracted human teeth were subjected for the study. Teeth were divided into 6 groups of 10 and 3 control groups of 10 teeth each. All the samples were decoronated and the coronal surfaces of the roots were prepared perpendicular to the long axis of the root with a high-speed handpiece and a multipurpose bur using air water spray. The length of all the roots was prepared approximately 16 mm from the coronal surface to the apex of the root. Roots were filled using lateral and vertical condensation techniques with gutta-percha and AH26 sealer (Group 1 and 2) or with gutta-percha and epiphany sealer (Group 3 and 4). Group 5 and 6 were filled with Resilon and epiphany sealer using the lateral and vertical condensation techniques. A split chamber microbial leakage model was used in which S. mutans placed in the upper chamber could reach the lower chamber only through the filled root canal. Group 7 and 8 (positive control) were filled with Resilon and gutta-percha without sealer and tested with bacteria, whereas Group 7 (negative control) was sealed with wax to test the seal between the chambers. Data were analyzed using Kruskal-Wallis test and Mann-Whitney U test. All positive groups (Group 7 and 8) showed leakage within 1 hour of the start of the study (100%), whereas none of the negative control (Group 9) leaked. The roots obturated with Resilon and epiphany (Group 5 and 6) showed minimal leakage, i.e., each with 6 leakages, which was significantly less than gutta-percha (Group 1-4), in which approximately 80% of specimens with either sealer or techniques leaked. Kruskal-Wallis test showed statistical significance when all groups were compared (P<0.05). Mann-Whitney U test compared the respective groups and found Resilon groups superior to gutta-percha groups (P<0.05). This study demonstrated that the new polymer-based Resilon and epiphany sealer using two obturating techniques, i.e., lateral as well as vertical condensation found to be significantly better than the gutta-percha.

  17. Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2015-01-01

    Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

  18. An Ice Block: A Novel Technique of Successful Prevention of Cement Leakage Using an Ice Ball

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uri, Ishaq Fahmi, E-mail: uri.isaac@gmail.com; Garnon, Julien, E-mail: juliengarnon@gmail.com; Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr

    2015-04-15

    We report three cases of painful bone metastases with extraosseous invasion treated with cementoplasty and cryoablation. Due to significant cortical loss in all cases, the ice ball was used simultaneously during cementoplasty to deter potential cement leakage. This was achieved by direct application of the ice ball against the cortical surface, resulting in adequate consolidation and successful containment of the cement within the treated bones. To the authors’ knowledge, this is the first report to describe such a combined technique.

  19. A Selected Operational History of the Internal Thermal Control System (ITCS) for International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Patel, Vipul P.; Winton, Dale; Ibarra, Thomas H.

    2004-01-01

    The Internal Thermal Control System (ITCS) has been developed jointly by Boeing Corporation, Huntsville, Alabama and Honeywell Engines & Systems, Torrance, California to meet the internal thermal control needs for the International Space Station (ISS). The ITCS provides heat removal for the critical life support systems and thermal conditioning for numerous experiment racks. The ITCS will be fitted on a number of modules on the ISS. The first US Element containing the ITCS, Node 1, was launched in December 1998. Since Node 1 does not contain a pump to circulate the fluid it was not filled with ITCS fluid until after the US Laboratory Module was installed. The second US Element module, US Laboratory Module, which contains the pumps and all the major ITCS control hardware, was launched in February 2001. The third US Element containing the ITCS, the US Airlock, was launched in July 2001. The dual loop system of the ITCS is comprised of a lowtemperature loop (LTL) and a moderate-temperature loop (MTL). Each loop has a pump package assembly (PPA), a system flow control assembly (SFCA), a threeway mixing valve (TWMV), several rack flow control assemblies (RFCA), cold plates, pressure sensors, temperature sensors, pump bypass assembly (PBA) and a heat exchanger. In addition, the MTL has an additional TWMV, a payload regeneration heat exchanger (P/RHE) and a manual flow control valve (MFCV). The LTL has a service performance and checkout unit (SPCU) heat exchanger. The two loops are linked via one loop crossover assembly (LCA) providing cross loop capabilities and a single PPA, two-loop functionality. One important parameter monitored by the ground stations and on-orbit is the amount of fluid leakage from the ITCS. ISS fluid leakage is of importance since ITCS fluid is costly to re-supply, may be difficult to clean up in zero-g, and if uncontained could lead to equipment failures and potential hazards. This paper examines the nominal leakage observed over period of a year of on-orbit operation and compares this with analysis predictions. This paper also addresses the off-nominal leakage and a fluid transfer event causing significant changes in accumulator quantity.

  20. Vapor containment tests of the rapid response system glovebox. Final report, December 1995-April 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arca, V.J.; Blewett, W.K.; Kinne, W.E.

    1996-10-01

    The Rapid Response System (RRS) is a trailer-mounted facility for demilitarizing Chemical Agent Identification Sets (CAIS), obsolete training kits containing ampules and/or bottles of chemical warfare agents (mustard and lewisite), or other industrial chemical compounds. The main component of the RRS is a glovebox divided into three areas - an airlock station, unpack station, and neutralization station, and the CAIS items are processed through each station by use of 11 glove ports. The glovebox is maintained at negative pressure differential by a gas-particulate filter-blower unit. To measure the performance of the glovebox in containing chemical vapors/gases, a series of testsmore » was conducted on 811 April 1996 at Tooele Army Depot, UT, with methyl salicylate, a simulant for mustard. This testing addressed performance in steady state operation, airlock cycling, waste barrel changeout, and glove changeout. Two trials were also conducted in a simulated power-failure condition to determine the rate of leakage if system airflow is interrupted. The glovebox and its engineering controls provided a very high level of protection. Some procedural changes were recommended to increase the protection factor in glove and barrel changeout operations.« less

  1. Development of references of anomalies detection on P91 material using Self-Magnetic Leakage Field (SMLF) technique

    NASA Astrophysics Data System (ADS)

    Husin, Shuib; Afiq Pauzi, Ahmad; Yunus, Salmi Mohd; Ghafar, Mohd Hafiz Abdul; Adilin Sekari, Saiful

    2017-10-01

    This technical paper demonstrates the successful of the application of self-magnetic leakage field (SMLF) technique in detecting anomalies in weldment of a thick P91 materials joint (1 inch thickness). Boiler components such as boiler tubes, stub boiler at penthouse and energy piping such as hot reheat pipe (HRP) and H-balance energy piping to turbine are made of P91 material. P91 is ferromagnetic material, therefore the technique of self-magnetic leakage field (SMLF) is applicable for P91 in detecting anomalies within material (internal defects). The technique is categorized under non-destructive technique (NDT). It is the second passive method after acoustic emission (AE), at which the information on structures radiation (magnetic field and energy waves) is used. The measured magnetic leakage field of a product or component is a magnetic leakage field occurring on the component’s surface in the zone of dislocation stable slipbands under the influence of operational (in-service) or residual stresses or in zones of maximum inhomogeneity of metal structure in new products or components. Inter-granular and trans-granular cracks, inclusion, void, cavity and corrosion are considered types of inhomogeneity and discontinuity in material where obviously the output of magnetic leakage field will be shown when using this technique. The technique does not required surface preparation for the component to be inspected. This technique is contact-type inspection, which means the sensor has to touch or in-contact to the component’s surface during inspection. The results of application of SMLF technique on the developed P91 reference blocks have demonstrated that the technique is practical to be used for anomaly inspection and detection as well as identification of anomalies’ location. The evaluation of this passive self-magnetic leakage field (SMLF) technique has been verified by other conventional non-destructive tests (NDTs) on the reference blocks where simulated defects/anomalies have been developed inside at the weldment. The results from the inspection test showed that the signatures of magnetic leakage field gradient distribution prove that the peak is found on the location of defect/anomaly in the reference block. It is in agreement with the evidence of anomaly that seen in the radiography test film (RT).

  2. R-134a emissions from vehicles.

    PubMed

    Siegl, W O; Wallington, T J; Guenther, M T; Henney, T; Pawlak, D; Duffy, M

    2002-02-15

    We report the first study of R-134a (also known as HFC-134a and CF3CFH2) refrigerant leakage from air conditioning (AC) systems of modern vehicles. Twenty-eight light duty vehicles from five manufacturers (Ford, Toyota, Daimler Chrysler, General Motors, and Honda) were tested according to the USEPA (Federal) extended diurnal test procedure using the Sealed Housing for Evaporative Determination (SHED) apparatus. All tests were conducted using stationary vehicles with the motor and air conditioning system turned off. R-134a was measured using gas chromatography (GC) with a flame ionization detector (FID). All vehicles exhibited measurable R-134a leakage over the 2-day diurnal test. Leak rates of R-134a ranged from 0.01 to 0.36 g/day with an average of 0.07+/-0.07 g/day. When combined with leakage associated with vehicle operation, servicing, and disposal we estimate that the lifetime average R-134a emission rate from an AC equipped vehicle is 0.41+/-0.27 g/day (the majority of emissions are associated with vehicle servicing and disposal). Assuming that the average vehicle travels 10 000 miles per year we estimate that the global warming impact of R-134a leakage from an AC equipped vehicle is approximately 4-5% of that of the CO2 emitted by the vehicle. The results are discussed with respect to the contribution of vehicle emissions to global climate change.

  3. An Advanced Helium Buffer Seal for the SSME, ATD Oxygen Pump

    NASA Technical Reports Server (NTRS)

    Shapiro, Wilbur

    2006-01-01

    The present configuration of Helium Buffer Seal on the ATD oxygen pump consists of a pair of opposed carbon rings are forced axially against their containment housings. Leakage occurs through the clearance between the rings and the shaft. The total helium leakage through both sides is approximately 239 SCFM. A reduction in leakage to 50 SCFM will result in less helium storage and consequently permit a substantial increase in payload. Under Phase 1 NASA SBIR, a solid T-Ring seal was analyzed and designed that could satisfy the criteria of reducing leakage to 50 SCFM or less. The design makes maximum use of available length and employs a mid length row of hydrostatic orifaces that feed buffer helium directly into a 2 to 3 mil clearance region. The flow splits into opposite paths to buffer oxygen gas on one side and hydrogen gas on the turbine side. The seal employs opposed hydrostatic tapered land secondary seals that provide friction free support of the primary seal and allows the primary seal to follow rotor excursion and maintain concentric operating clearance . The predicted performance of the T-seal is excellent with operation at a safe film thickness of 2 to 2.5 mils and leakage less than 50 SCFM.

  4. Development of helicopter engine seals

    NASA Technical Reports Server (NTRS)

    Lynwander, P.

    1973-01-01

    An experimental evaluation of main shaft seals for helicopter gas turbine engines was conducted with shaft speeds to 213 m/s(700 ft/sec), air pressures to 148 N/sq cm (215 psia), and air temperatures to 645 K (675 F). Gas leakage test results indicate that conventional seals will not be satisfactory for high-pressure sealing because of excessive leakage. The self-acting face seal, however, had significantly lower leakage and operated with insignificant wear during a 150-hour endurance test at sliding speeds to 145 m/s (475 ft/sec), air pressures to 124 N/sq cm (180 psia), and air temperatures to 408 K (275 F). Wear measurements indicate that noncontact operation was achieved at shaft speeds of 43,000 rpm. Evaluation of the self-acting circumferential seal was inconclusive because of seal dimensional variations.

  5. Serum from dengue virus-infected patients with and without plasma leakage differentially affects endothelial cells barrier function in vitro

    PubMed Central

    Baimukanova, Gyulnar; Lanteri, Marion Christine; Keating, Sheila Marie; Moraes Ferreira, Frederico; Heitman, John; Pannuti, Cláudio Sérgio; Pati, Shibani; Romano, Camila Malta; Cerdeira Sabino, Ester

    2017-01-01

    Background Although most of cases of dengue infections are asymptomatic or mild symptomatic some individuals present warning signs progressing to severe dengue in which plasma leakage is a hallmark. Methodology/Principal findings The present study used Electric Cell-substrate Impedance Sensing (ECIS®) which allows for electrical monitoring of cellular barrier function measuring changes in Transendothelial Electric Resistance (TEER) to investigate the parameters associated with dengue induced leakage. Three groups of individuals were tested: dengue-positives with plasma leakage (leakage), dengue-positives without plasma leakage (no leakage), and dengue-negatives (control). Data show that TEER values of human umbilical vein endothelial cells (HUVECs) was significantly lower after incubation with serum from subjects of the leakage group in comparison to the no leakage or control groups. The serum levels of CXCL1, EGF, eotaxin, IFN-γ, sCD40L, and platelets were significantly decreased in the leakage group, while IL-10, IL-6, and IP-10 levels were significantly increased. We also found a strong correlation between TEER values and augmented levels of IP-10, GM-CSF, IL-1α, and IL-8, as well as decreased levels of CXCL1 and platelets. Conclusions/Significance The present work shows that the magnitude of the immune response contributes to the adverse plasma leakage outcomes in patients and that serum components are important mediators of changes in endothelial homeostasis during dengue infections. In particular, the increased levels of IP-10 and the decreased levels of CXCL1 and platelets seem to play a significant role in the disruption of vascular endothelium associated with leakage outcomes after DENV infection. These findings may have important implications for both diagnostic and therapeutic approaches to predict and mitigate vascular permeabilization in those experiencing the most severe clinical disease outcomes after dengue infection. PMID:28586397

  6. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study.

    PubMed

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann-Whitney U-test, Kruskal-Wallis H-test and the results were statistically significant P < 0.05 the power of study - 80%. Marginal leakage was significant in both provisional crowns cemented with three different luting cements along the axial walls of teeth (P < 0.05) confidence interval - 95%. The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage.

  7. Germline contamination and leakage in whole genome somatic single nucleotide variant detection.

    PubMed

    Sendorek, Dorota H; Caloian, Cristian; Ellrott, Kyle; Bare, J Christopher; Yamaguchi, Takafumi N; Ewing, Adam D; Houlahan, Kathleen E; Norman, Thea C; Margolin, Adam A; Stuart, Joshua M; Boutros, Paul C

    2018-01-31

    The clinical sequencing of cancer genomes to personalize therapy is becoming routine across the world. However, concerns over patient re-identification from these data lead to questions about how tightly access should be controlled. It is not thought to be possible to re-identify patients from somatic variant data. However, somatic variant detection pipelines can mistakenly identify germline variants as somatic ones, a process called "germline leakage". The rate of germline leakage across different somatic variant detection pipelines is not well-understood, and it is uncertain whether or not somatic variant calls should be considered re-identifiable. To fill this gap, we quantified germline leakage across 259 sets of whole-genome somatic single nucleotide variant (SNVs) predictions made by 21 teams as part of the ICGC-TCGA DREAM Somatic Mutation Calling Challenge. The median somatic SNV prediction set contained 4325 somatic SNVs and leaked one germline polymorphism. The level of germline leakage was inversely correlated with somatic SNV prediction accuracy and positively correlated with the amount of infiltrating normal cells. The specific germline variants leaked differed by tumour and algorithm. To aid in quantitation and correction of leakage, we created a tool, called GermlineFilter, for use in public-facing somatic SNV databases. The potential for patient re-identification from leaked germline variants in somatic SNV predictions has led to divergent open data access policies, based on different assessments of the risks. Indeed, a single, well-publicized re-identification event could reshape public perceptions of the values of genomic data sharing. We find that modern somatic SNV prediction pipelines have low germline-leakage rates, which can be further reduced, especially for cloud-sharing, using pre-filtering software.

  8. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.

    PubMed

    Chen, Jia-Kun

    2016-08-01

    An inclined plate for flow control was installed at the lower edge of the sash of an inclined air-curtain fume hood to reduce the effects of the wake around a worker standing in front of the fume hood. Flow inside the fume hood is controlled by the inclined air-curtain and deflection plates, thereby forming a quad-vortex flow structure. Controlling the face velocity of the fume hood resulted in convex, straight, concave, and attachment flow profiles in the inclined air-curtain. We used the flow visualization and conducted a tracer gas test with a mannequin to determine the performance of two sash geometries, namely, the half-cylinder and inclined plate designs. When the half-cylinder design was used, the tracer gas test registered a high leakage concentration at Vf ≦ 57.1 fpm or less. This concentration occurred at the top of the sash opening, which was close to the breathing zone of the mannequin placed in front of the fume hood. When the inclined plate design was used, the containment was good, with concentrations of 0.002-0.004 ppm, at Vf ≦ 63.0 fpm. Results indicate that an inclined plate effectively reduces the leakage concentration induced by recirculation flow structures that form in the wake of a worker standing in front of an inclined air-curtain fume hood.

  9. Experimental evaluation of clinical colon anastomotic leakage.

    PubMed

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the model. In the final experiment, the four-suture anastomoses resulted in a 40% leakage rate in the intervention groups, whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3: This experimental study used 53 C57BL/6 mice, in which sufficient eight-suture anastomoses were created. By using bipolar electro-cautery, blood supply was reduced in a stepwise manner to create anastomotic leakage as a result of ischemia. The study showed that reduced blood supply led to large bowel obstruction instead of clinical leakage. However, anastomotic breaking strength was reduced in the ischemic anastomoses. STUDY 4: In this systematic review MEDLINE, Embase and Cinahl were searched up to September 2011 to identify studies evaluating external coating of colonic anastomoses. Most studies were experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil, and polyethylene glycols may be beneficial. However, further experimental and clinical studies are needed before routine clinical use can be recommended. The studies in this thesis may be valuable for the experimental research field of clinical anastomotic leakage. The model of technical insufficiency has been improved and is now thoroughly validated. If used by researchers worldwide, comparison of results is possible. Pure ischemia/anoxia may be too simple an approach to create a clinical leakage model. Thus, future models could focus on multiple risk factors. Conclusively, large-scale clinical multicenter studies are needed to definitively evaluate whether coating of colorectal anastomoses may reduce the leakage rate.

  10. Effects of low-pressure air on oxygen contamination and lithium corrosion of a tantalum alloy, T-111, at 980 and 1260 C

    NASA Technical Reports Server (NTRS)

    Gahn, R. F.

    1974-01-01

    The effects were studied of low-pressure air on contamination and corrosion in the tantalum alloy T-111/lithium system at 980 and 1260 C. Capsules of T-111 containing lithium were exposed to six vacuum levels between 1 x 10 to the 8th power and 0.0003 torr by controlled air leakage into a vacuum system. Capsules exposed at 980 C and 0.0002 torr failed from intragranular oxidation. The remainder of the capsules completed the 96-hour tests. The depth of oxygen contamination was greater at 980 C than at 1260 C. Tests made at 0.0001 and 0.00001 torr levels caused large increases in the oxygen content of the T-111. Tests at 0.000001 torr or less produced no significant contamination. No lithium corrosion of the T-111 was observed under any of the conditions.

  11. Optical Detection Of Cryogenic Leaks

    NASA Technical Reports Server (NTRS)

    Wyett, Lynn M.

    1988-01-01

    Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

  12. Passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1989-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  13. Atomic Oxygen Effects on Seal Leakage

    NASA Technical Reports Server (NTRS)

    Christensen, John R.; Underwood, Steve D.; Kamenetzky, Rachel R.; Vaughn, Jason A.

    1999-01-01

    Common Berthing Mechanism (CBM provides the structural interface between separate International Space Station (ISS) elements, such as the Laboratory and Node modules. The CBM consists of an active and a passive half that join together with structural bolts. The seal at this interface is the CBM-to-CBM molded seal. The CBM-to-CBM interface is assembled on orbit, thus the seals can be exposed to the space environment for up to 65 hours. Atomic Oxygen/Vacuum Ultraviolet radiation (AO/VUV) in space is a potential hazard to the seals. Testing was conducted to determine the effect on leakage of the CBM-to-CBM seal material exposed to AO/VUV. The sealing materials were S383 silicone and V835 fluorocarbon material. Control samples, which were not exposed to the AO/VUV environment, were used to ensure that ff any changes in leakage occurred, they could be attributed to the AO/VUV exposure. After exposure to the AO/VUV environment the leakage increase was dramatic for the fluorocarbon. This testing was a major contributing factor in selecting silicone as the CBM-to-CBM seal material.

  14. A meta-analysis of the use of a transanal drainage tube to prevent anastomotic leakage after anterior resection by double-stapling technique for rectal cancer.

    PubMed

    Shigeta, Kohei; Okabayashi, Koji; Baba, Hideo; Hasegawa, Hirotoshi; Tsuruta, Masashi; Yamafuji, Kazuo; Kubochi, Kiyoshi; Kitagawa, Yuko

    2016-02-01

    The safety and efficacy of transanal drainage tube (TDT) placement to decrease the risk of postoperative anastomotic leakage after rectal cancer surgery has not been validated. The objective of this meta-analysis was to evaluate the usefulness of a TDT for the prevention of anastomotic leakage after an anterior resection for rectal cancer. The PubMed and Cochrane Library databases were searched for studies comparing TDT and non-TDT. The endpoint utilized in this study was defined as the rates of anastomotic leakage and re-operation. The relative effects of these variables were synthesized using Review Manager 5.1 software. Four trials including 909 participants (401 TDT cases and 508 non-TDT cases) met our inclusion criteria. The weighted mean anastomotic leakage rate was 4% [95% confidence interval (CI) 1-6%], and a significantly lower risk of anastomotic leakage was identified in the TDT group compared with the non-TDT group [odds ratio (OR) 0.30; 95% CI 0.16-0.55; p = 0.0001]. Furthermore, there were significant differences between the TDT and non-TDT groups in terms of the re-operation rate (OR 0.18; 95% CI 0.07-0.44; p = 0.0002). No significant covariates related to anastomotic leakage or re-operation were identified in meta-regression analysis. Both the anastomotic leakage and re-operation rates for all studies lay inside the 95% confidence interval boundaries. No visible publication bias was found by visual assessment of the funnel plot (Egger's test; anastomotic leakage: p = 0.056, re-operation: p = 0.681). Placement of a TDT is an effective and safe procedure that can decrease the rate of anastomotic leakage and re-operation after an anterior resection.

  15. A comparative study on sealing ability of mineral trioxide aggregate, calcium enriched cement and bone cement in furcal perforations.

    PubMed

    Nazari Moghadam, K; Aghili, H; Rashed Mohassel, A; Zahedpasha, S; Moghadamnia, A A

    2014-06-01

    The aim of this study was to compare the bacterial leakage of mineral trioxide aggregate (MTA), calcium enriched cement (CEM), and bone cement (BC) as repair materials in furcal perforations. The pulp chambers of 57 human mandibular molar teeth were accessed and the root canal orifices were located. The roots were horizontally sectioned in the middle third. Composite resin was used to fill the root canal orifices and the apical end of the roots. The 1 mm furcation perforations were performed in the center of the pulp chamber floor, using diamond fissure burs. Fifty one teeth were divided into 3 groups. Six teeth were used as controls. Perforation defects were repaired with either MTA, CEM, or BC. A bacterial leakage model utilizing phenol red with 3% lactose broth was used for evaluation. The upper pulp chambers were subsequently filled with 5μL bacterial suspension containing Enterococcus faecalis. Then the top of the assembly was covered with aluminum foil to avoid unintentional contamination. The entire apparatus was incubated at 37°C, and bacterial leakage was evaluated daily by checking the turbidity in the culture medium of the lower part of the chamber. The bacterial inoculation was renewed every day, for 30 days. Leakage was noted when color conversion of the culture media was observed and was statistically analyzed using the Chi-square test with significance set at P< 0.05. Sixteen (94%) of the 17 samples of the MTA group, thirteen (81%) of the 17 samples of the CEM group and sixteen (94%) of the 17 samples in BC group were fully contaminated at 30 days. There was no statistically significant difference between the three study groups (P>0.05). According to the present study, in teeth with furcation perforations, the coronal seal produced by MTA preparations was equally to that produced by CEM cement and Bone cement.

  16. Feasibility of Autonomous Monitoring of CO2 Leakage in Aquifers: Results From Controlled Laboratory Experiments

    NASA Astrophysics Data System (ADS)

    Versteeg, R.; Leger, E.; Dafflon, B.

    2016-12-01

    Geologic sequestration of CO2 is one of the primary proposed approaches for reducing total atmospheric CO2 concentrations. MVAA (Monitoring, Verification, Accounting and Assessment) of CO2 sequestration is an essential part of the geologic CO2 sequestration cycle. MVAA activities need to meet multiple operational, regulatory and environmental objectives, including ensuring the protection of underground sources of drinking water. Anticipated negative consequences of CO2 leakage into groundwater, besides possible brine contamination and release of gaseous CO2, include a significant increase of dissolved CO2 into shallow groundwater systems, which will decrease groundwater pH and can potentially mobilize naturally occurring trace metals and ions that are commonly absorbed to or contained in sediments. Autonomous electrical geophysical monitoring in aquifers has the potential of allowing for rapid and automated detection of CO2 leakage. However, while the feasibility of such monitoring has been demonstrated by a number of different field experiments, automated interpretation of complex electrical resistivity data requires the development of quantitative relationships between complex electrical resistivity signatures and dissolved CO2 in the aquifer resulting from leakage Under a DOE SBIR funded effort we performed multiple tank scale experiments in which we investigated complex electrical resistivity signatures associated with dissolved CO2 plumes in saturated sediments. We also investigated the feasibility of distinguishing CO2 leakage signatures from signatures associated with other processes such as salt water movement, temperature variations and other variations in chemical or physical conditions. In addition to these experiments we also numerically modeled the tank experiments. These experiments showed that (a) we can distinguish CO2 leakage signatures from other signatures, (b) CO2 leakage signatures have a consistent characteristic, (c) laboratory experiments are in agreement with field results, and (d) we can numerically simulate the main characteristics of CO2 leakage and associated electrical geophysical signatures.

  17. Actively Controlled Shaft Seals for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Salant, Richard F.; Wolff, Paul

    1995-01-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with a piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changes suddenly. the experimental results were compared to the predictions from the mathematical model. The model was successful in predicting the trends in leakage rate that occurred as the balance ratio and sealed pressure changed, although the leakage rates were not quantitatively predicted with a high degree of accuracy. This model could be useful in providing valuable design information for future actively controlled mechanical seals.

  18. The influence of shrouded stator cavity flows on multistage compressor performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wellborn, S.R.; Okiishi, T.H.

    1999-07-01

    Experiments were performed on a low-speed multistage axial-flow compressor to assess the effects of shrouded stator cavity flows on aerodynamic performance. Five configurations, which involved systematic changes in seal-tooth leakage rates and/or elimination of the shrouded stator cavities, were tested. Rig data indicate increasing seal-tooth leakage substantially degraded compressor performance. For every 1 percent increase in seal-tooth clearance-to-span ratio, the decrease in pressure rise was 3 percent and the reduction in efficiency was 1 point. These observed performance penalties are comparable to those commonly reported for rotor and cantilevered stator tip clearance variations. The performance degradation observed with increased leakagemore » was brought about in two distinct ways. First, increasing seal-tooth leakage directly spoiled the near-hub performance of the stator row in which leakage occurred. Second, the altered stator exit flow conditions, caused by increased leakage, impaired the performance of the next downstream stage by decreasing the work input of the rotor and increasing total pressure loss of the stator. These trends caused the performance of downstream stages to deteriorate progressively. Numerical simulations of the test rig stator flow field were also conducted to help resolve important fluid mechanic details associated with the interaction between the primary and cavity flows. Simulation results show that fluid originating in the upstream cavity collected on the stator suction surface when the cavity tangential momentum was low and on the pressure side when it was high. The convection of cavity fluid to the suction surface was a mechanism that reduced stator performance when leakage increased.« less

  19. Omitting chest tube drainage after thoracoscopic major lung resection.

    PubMed

    Ueda, Kazuhiro; Hayashi, Masataro; Tanaka, Toshiki; Hamano, Kimikazu

    2013-08-01

    Absorbable mesh and fibrin glue applied to prevent alveolar air leakage contribute to reducing the length of chest tube drainage, length of hospitalization and the rate of pulmonary complications. This study investigated the feasibility of omitting chest tube drainage in selected patients undergoing thoracoscopic major lung resection. Intraoperative air leakages were sealed with fibrin glue and absorbable mesh in patients undergoing thoracoscopic major lung resection. The chest tube was removed just after tracheal extubation if no air leakages were detected in a suction-induced air leakage test, which is an original technique to confirm pneumostasis. Patients with bleeding tendency or extensive thoracic adhesions were excluded. Chest tube drainage was omitted in 29 (58%) of 50 eligible patients and was used in 21 (42%) on the basis of suction-induced air leakage test results. Male gender and compromised pulmonary function were significantly associated with the failure to omit chest tube drainage (both, P < 0.05). Regardless of omitting the chest tube drainage, there were no adverse events during hospitalization, such as subcutaneous emphysema, pneumothorax, pleural effusion or haemothorax, requiring subsequent drainage. Furthermore, there was no prolonged air leakage in any patients: The mean length of chest tube drainage was only 0.9 days. Omitting the chest tube drainage was associated with reduced pain on the day of the operation (P = 0.046). The refined strategy for pneumostasis allowed the omission of chest tube drainage in the majority of patients undergoing thoracoscopic major lung resection without increasing the risk of adverse events, which may contribute to a fast-track surgery.

  20. A method for simulating the entire leaking process and calculating the liquid leakage volume of a damaged pressurized pipeline.

    PubMed

    He, Guoxi; Liang, Yongtu; Li, Yansong; Wu, Mengyu; Sun, Liying; Xie, Cheng; Li, Feng

    2017-06-15

    The accidental leakage of long-distance pressurized oil pipelines is a major area of risk, capable of causing extensive damage to human health and environment. However, the complexity of the leaking process, with its complex boundary conditions, leads to difficulty in calculating the leakage volume. In this study, the leaking process is divided into 4 stages based on the strength of transient pressure. 3 models are established to calculate the leaking flowrate and volume. First, a negative pressure wave propagation attenuation model is applied to calculate the sizes of orifices. Second, a transient oil leaking model, consisting of continuity, momentum conservation, energy conservation and orifice flow equations, is built to calculate the leakage volume. Third, a steady-state oil leaking model is employed to calculate the leakage after valves and pumps shut down. Moreover, sensitive factors that affect the leak coefficient of orifices and volume are analyzed respectively to determine the most influential one. To validate the numerical simulation, two types of leakage test with different sizes of leakage holes were conducted from Sinopec product pipelines. More validations were carried out by applying commercial software to supplement the experimental insufficiency. Thus, the leaking process under different leaking conditions are described and analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Brush Seals for Cryogenic Applications: Performance, Stage Effects, and Preliminary Wear Results in LN2 and LH2

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Walker, James F.; Perkins, H. Douglas; Hoopes, Joan F.; Williamson, G. Scott

    1996-01-01

    Brush seals are compliant contacting seals and have significantly lower leakage than labyrinth seals in gas turbine applications. Their long life and low leakage make them candidates for use in rocket engine turbopumps. Brush seals, 50.8 mm (2 in.) in diameter with a nominal 127-micron (0.005-in.) radial interference, were tested in liquid nitrogen (LN2) and liquid hydrogen (LH2) at shaft speeds up to 35,000 and 65,000 rpm, respectively, and at pressure drops up to 1.21 MPa (175 psid) per brush. A labyrinth seal was also tested in liquid nitrogen to provide a baseline. The LN2 leakage rate of a single brush seal with an initial radial shaft interference of 127 micron (0.005 in.) measured one-half to one-third the leakage rate of a 12-tooth labyrinth seal with a radial clearance of 127 micron (0.005 in.). Two brushes spaced 7.21 micron (0.248 in.) apart leaked about one-half as much as a single brush, and two brushes tightly packed together leaked about three-fourths as much as a single brush. The maximum measured groove depth on the Inconel 718 rotor with a surface finish of 0.81 micron (32 microinch) was 25 micron (0.0010 in.) after 4.3 hr of shaft rotation in liquid nitrogen. The Haynes-25 bristles wore approximately 25 to 76 micron (0.001 to 0.003 in.) under the same conditions. Wear results in liquid hydrogen were significantly different. In liquid hydrogen the rotor did not wear, but the bristle material transferred onto the rotor and the initial 127 micron (0.005 in.) radial interference was consumed. Relatively high leakage rates were measured in liquid hydrogen. More testing is required to verify the leakage performance, to validate and calibrate analysis techniques, and to determine the wear mechanisms. Performance, staging effects, and preliminary wear results are presented.

  2. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    PubMed

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  3. Portable Microleak-Detection System

    NASA Technical Reports Server (NTRS)

    Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.

    2007-01-01

    The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

  4. SU-E-T-646: Quality Assurance of Truebeam Multi-Leaf Collimator Using a MLC QA Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Lu, J; Hong, D

    2015-06-15

    Purpose: To perform a routine quality assurance procedure for Truebeam multi-leaf collimator (MLC) using MLC QA phantom, verify the stability and reliability of MLC during the treatment. Methods: MLC QA phantom is a specialized phantom for MLC quality assurance (QA), and contains five radio-opaque spheres that are embedded in an “L” shape. The phantom was placed isocentrically on the Truebeam treatment couch for the tests. A quality assurance plan was setted up in the Eclipse v10.0, the fields that need to be delivered in order to acquire the necessary images, the MLC shapes can then be obtained by the images.more » The images acquired by the electronic portal imaging device (EPID), and imported into the PIPSpro software for the analysis. The tests were delivered twelve weeks (once a week) to verify consistency of the delivery, and the images are acquired in the same manner each time. Results: For the Leaf position test, the average position error was 0.23mm±0.02mm (range: 0.18mm∼0.25mm). The Leaf width was measured at the isocenter, the average error was 0.06mm±0.02mm (range: 0.02mm∼0.08mm) for the Leaf width test. Multi-Port test showed the dynamic leaf shift error, the average error was 0.28mm±0.03mm (range: 0.2mm∼0.35mm). For the leaf transmission test, the average inter-leaf leakage value was 1.0%±0.17% (range: 0.8%∼1.3%) and the average inter-bank leakage value was 32.6%±2.1% (range: 30.2%∼36.1%). Conclusion: By the test of 12 weeks, the MLC system of the Truebeam is running in a good condition and the MLC system can be steadily and reliably carried out during the treatment. The MLC QA phantom is a useful test tool for the MLC QA.« less

  5. Design Support of an Above Cap-rock Early Detection Monitoring System using Simulated Leakage Scenarios at the FutureGen2.0 Site

    DOE PAGES

    Williams, Mark D.; USA, Richland Washington; Vermuel, Vince R.; ...

    2014-12-31

    The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO 2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to evaluate CO 2 mass balance and detect any unforeseen loss in CO 2 containment. The monitoring program will include direct monitoring of the reservoir, and early-leak-detection monitoring directly above the primary confining zone. This preliminary modeling study described here focuses on hypotheticalmore » leakage scenarios into the first permeable unit above the primary confining zone (Ironton Sandstone) and is used to support assessment of early-leak detection capabilities. Future updates of the model will be used to assess potential impacts on the lowermost underground source of drinking water (Saint Peter Sandstone) for a range of theoretical leakage scenarios. This preliminary modeling evaluation considers both pressure response and geochemical signals in the overlying Ironton Sandstone. This model is independent of the FutureGen 2.0 reservoir model in that it does not simulate caprock discontinuities, faults, or failure scenarios. Instead this modeling effort is based on theoretical, volumetric-rate based leakage scenarios. The scenarios include leakage of 1% of the total injected CO 2 mass, but spread out over different time periods (20, 100, and 500 years) with each case yielding a different mass flux (i.e., smaller mass fluxes for longer duration leakage cases]. A brine leakage scenario using a volumetric leakage similar to the 20 year 1% CO 2 case was also considered. A framework for the comparison of the various cases was developed based on the exceedance of selected pressure and geochemical thresholds at different distances from the point of leakage and at different vertical positions within the Ironton Sandstone. These preliminary results, and results from an updated models that incorporate additional site-specific characterization data, support development/refinement of the monitoring system design.« less

  6. Annular honeycomb seals: Test results for leakage and rotordynamic coefficients; comparisons to labyrinth and smooth configurations

    NASA Technical Reports Server (NTRS)

    Childs, Dara W.; Elrod, David; Hale, Keith

    1989-01-01

    Test results are presented for leakage and rotordynamic coefficients for seven honeycomb seals. All seals have the same radius, length, and clearance; however, the cell depths and diameters are varied. Rotordynamic data, which are presented, consist of the direct and cross-coupled stiffness coefficients and the direct damping coefficients. The rotordynamic-coefficient data show a considerable sensitivity to changes in cell dimensions; however, no clear trends are identifiable. Comparisons of test data for the honeycomb seals with labyrinth and smooth annular seals show the honeycomb seal had the best sealing (minimum leakage) performance, followed in order by the labyrinth and smooth seals. For prerotated fluid entering the seal, in the direction of shaft rotation, the honeycomb seal has the best rotordynamic stability followed in order by the labyrinth and smooth. For no prerotation, or fluid prerotation against shaft rotation, the labyrinth seal has the best rotordynamic stability followed in order by the smooth and honeycomb seals.

  7. Air Leakage and Air Transfer Between Garage and Living Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  8. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-housemore » air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  9. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressuremore » relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.« less

  10. Printed Circuit Board Surface Finish and Effects of Chloride Contamination, Electric Field, and Humidity on Corrosion Reliability

    NASA Astrophysics Data System (ADS)

    Conseil-Gudla, Hélène; Jellesen, Morten S.; Ambat, Rajan

    2017-02-01

    Corrosion reliability is a serious issue today for electronic devices, components, and printed circuit boards (PCBs) due to factors such as miniaturization, globalized manufacturing practices which can lead to process-related residues, and global usage effects such as bias voltage and unpredictable user environments. The investigation reported in this paper focuses on understanding the synergistic effect of such parameters, namely contamination, humidity, PCB surface finish, pitch distance, and potential bias on leakage current under different humidity levels, and electrochemical migration probability under condensing conditions. Leakage currents were measured on interdigitated comb test patterns with three different types of surface finish typically used in the electronics industry, namely gold, copper, and tin. Susceptibility to electrochemical migration was studied under droplet conditions. The level of base leakage current (BLC) was similar for the different surface finishes and NaCl contamination levels up to relative humidity (RH) of 65%. A significant increase in leakage current was found for comb patterns contaminated with NaCl above 70% to 75% RH, close to the deliquescent RH of NaCl. Droplet tests on Cu comb patterns with varying pitch size showed that the initial BLC before dendrite formation increased with increasing NaCl contamination level, whereas electrochemical migration and the frequency of dendrite formation increased with bias voltage. The effect of different surface finishes on leakage current under humid conditions was not very prominent.

  11. Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1935-01-01

    Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

  12. Voltage equaliser for Li-Fe battery

    NASA Astrophysics Data System (ADS)

    Wu, Jinn-Chang; Jou, Hurng-Liahng; Chuang, Ping-Hao

    2013-10-01

    In this article, a voltage equaliser is proposed for a battery string with four Li-Fe batteries. The proposed voltage equaliser is developed from a flyback converter, which comprises a transformer, a power electronic switch and a resonant clamped circuit. The transformer contains a primary winding and four secondary windings with the same number of turns connected to each battery. The resonant clamped circuit is for recycling the energy of leakage inductance of the transformer and for performing zero-voltage switching (ZVS) of the power electronic switch. When the power electronic switch is switched on, the energy is stored in the transformer; and when the power electronic switch is switched off, the energy stored in the transformer will automatically charge the battery whose voltage is the lowest. In this way, the voltage of individual batteries in the battery string is balanced. The salient features of the proposed voltage equaliser are that only one switch is used, the energy stored in the leakage inductance of the transformer can be recycled and ZVS is obtained. A prototype is developed and tested to verify the performance of the proposed voltage equaliser. The experimental results show that the proposed voltage equaliser achieves the expected performance.

  13. Aberrant wound-healing response in mitomycin C-treated leaking blebs: a histopathologic study.

    PubMed

    Elner, Victor M; Newman-Casey, Paula Anne; Patil, A Jayaprakash; Flint, Andrew; Biswas, Jyotirmay; Moroi, Sayoko E; Pushparaj, Vaijayanthi; Edward, Deepak P

    2009-08-01

    To characterize histopathologic features of leaking mitomycin C-treated blebs and aberrant wound healing that may lead to persistent conjunctival thinning and leakage. Forty mitomycin C-treated filtering blebs excised for persistent leaks from 40 patients were examined histopathologically using hematoxylin-eosin, periodic acid-Schiff, Masson trichrome, and Alcian blue histochemical stains. Ninety percent of the leaking blebs contained epithelial-stromal domes with areas of acellular stroma covered by attenuated epithelium. Seventy-five percent of the blebs demonstrated varying degrees of fibrovascular repair growing from the bleb margin, either beneath or interdigitating with the acellular zone. A novel observation in 65% of specimens was Alcian blue-positive myxoid stroma at the interface between the fibrovascular proliferation and the epithelial-stromal dome. The association between the presence of fibrovascular proliferation and Alcian blue-staining myxoid stroma was significant by Fisher exact test (P = .002). A desirable filtration bleb requires a sufficient reparative fibrovascular response to maintain an epithelial-stromal barrier to prevent leakage. Fibroblasts must lay down a continuous collagen-rich fibrous layer, rather than merely myxoid stroma, beneath the conjunctival epithelium to promote bleb stability. Surgical techniques and postsurgical care should aim to attain this desired outcome.

  14. A prototype urine collection device for female aircrew

    NASA Technical Reports Server (NTRS)

    Bisson, Roger U.; Delger, Karlyna L.

    1993-01-01

    Women are gaining increased access to small military cockpits. This shift has stimulated the search for practical urine containment and disposal methods for female aircrew. There are no external urine collection devices (UCD) for women that are comfortable, convenient, and leak free. We describe a prototype UCD that begins to meet this need. Materials used to make custom aviator masks were adapted to mold a perineal mask. First, a perineal cast (negative) was used to make a mold (positive). Next, a perineal mask made of wax was formed to fit the positive mold. Finally, a soft, pliable perineal mask was fabricated using the wax model as a guide. The prototype was tested for comfort, fit, and leakage. In the sitting position, less than 5 cc of urine leakage occurred with each 600 cc of urine collected. Comfort was mostly satisfactory, but ambulation was limited and the outlet design could lead to kinking and obstruction. We concluded that a perineal mask may serve as a comfortable and functional external UCD acceptable for use by females in confined environments. Changes are needed to improve comfort, fit, and urine drainage. Integration into cockpits, pressure suits, chemical defense gear, and environments where access to relief facilities is restricted is planned.

  15. Coupled Geochemical Impacts of Leaking CO2 and Contaminants from Subsurface Storage Reservoirs on Groundwater Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Hongbo; Qafoku, Nikolla; Lawter, Amanda R.

    2015-07-07

    The leakage of CO2 and the concomitant saline solutions from deep storage reservoirs to overlying groundwater aquifers is considered one of the major potential risks associated with geologic CO2 sequestration (GCS). Batch and column experiments were conducted to determine the fate of trace metals in groundwater in the scenarios of CO2 and metal contaminated brine leakage. The sediments used in this work were collected from an unconsolidated sand and gravel aquifer in Kansas, and contained 0-4 wt% carbonates. Cd and As were spiked into the reaction system to represent potential contaminants from the reservoir brine that could intrude into groundwatermore » aquifers with leaking CO2 at initial concentrations of 114 and 40 ppb, respectively. Through this research we demonstrated that Cd and As were adsorbed on the sediments, in spite of the lowered pH due to CO2 dissolution in the groundwater. Cd concentrations were well below its MCL in both batch and column studies, even for sediment samples without detectable carbonate to buffer the pH. Arsenic concentrations in the effluent were also significantly lower than influent concentration, suggesting that the sediments tested have the capacity to mitigate the coupled adverse effects of CO2 leakage and brine intrusion. However, the mitigation capacity of sediment is a function of its geochemical properties [e.g., the calcite content; the presence of adsorbed As(III); and the presence of P in the natural sediment]. The competitive adsorption between phosphate and arsenate may result in higher concentrations of As in the aqueous phase.« less

  16. Bidirectional Brush Seals

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Wilson, Jack; Wu, Tom; Flower, Ralph

    1997-01-01

    Presented is a study of the use of a set of I.D./O.D. bidirectional press seals to reduce the leakage losses in a wave rotor. Relative to the baseline configuration, data indicate the use of brush seals enhanced wave rotor efficiency from 36 to 45 percent at low leakages (small rotor endwall gap spacings) and from 15 to 33 percent at high leakages (larger endwall gap spacings). These brush seals are capable of sealing positive or negative pressure drops with respect to the axial direction. Surface tribology for these tests suggested little evidence of grooving although the bristles appeared polished.

  17. 30 CFR 250.804 - Production safety-system testing and records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Production Safety... minute or a gas leakage rate in excess of 5 cubic feet per minute is observed, the device shall be... cubic centimeters per minute or a gas leakage rate in excess of 5 cubic feet per minute is observed, the...

  18. Geochemical Impacts of Carbon Dioxide, Brine, Trace Metal and Organic Leakage into an Unconfined, Oxidizing Limestone Aquifer

    DOE PAGES

    Bacon, Diana H.; Dai, Zhenxue; Zheng, Liange

    2014-12-31

    An important risk at CO2 storage sites is the potential for groundwater quality impacts. As part of a system to assess the potential for these impacts a geochemical scaling function has been developed, based on a detailed reactive transport model of CO2 and brine leakage into an unconfined, oxidizing carbonate aquifer. Stochastic simulations varying a number of geochemical parameters were used to generate a response surface predicting the volume of aquifer that would be impacted with respect to regulated contaminants. The brine was assumed to contain several trace metals and organic contaminants. Aquifer pH and TDS were influenced by CO2more » leakage, while trace metal concentrations were most influenced by the brine concentrations rather than adsorption or desorption on calcite. Organic plume sizes were found to be strongly influenced by biodegradation.« less

  19. Drift stabilizer for reciprocating free-piston devices

    DOEpatents

    Ward, William C.; Corey, John A.; Swift, Gregory W.

    2003-05-20

    A free-piston device has a stabilized piston drift. A piston having a frequency of reciprocation over a stroke length and with first and second sides facing first and second variable volumes, respectively, for containing a working fluid defining an acoustic wavelength at the frequency of reciprocation. A bypass tube waveguide connects the first and second variable volumes at all times during reciprocation of the piston. The waveguide has a relatively low impedance for steady flow and a relatively high impedance for oscillating flow at the frequency of reciprocation of the piston, so that steady flow returns fluid leakage from about the piston between the first and second volumes while oscillating flow is not diverted through the waveguide. Thus, net leakage about the piston is returned during each stroke of the piston while oscillating leakage is not allowed and pressure buildup on either the first or second side of the piston is avoided to provide a stable piston location.

  20. Antimicrobial Peptide Lactoferricin B-Induced Rapid Leakage of Internal Contents from Single Giant Unilamellar Vesicles.

    PubMed

    Moniruzzaman, Md; Alam, Jahangir Md; Dohra, Hideo; Yamazaki, Masahito

    2015-09-29

    Enzymatic digestion of bovine lactoferrin generates lactoferricin B (Lfcin B), a 25-mer peptide with strong antimicrobial activity of unknown mechanism. To elucidate the mechanistic basis of Lfcin B bactericidal activity, we investigated the interaction of Lfcin B with Escherichia coli and liposomes of lipid membranes. Lfcin B induced the influx of a membrane-impermeant fluorescent probe, SYTOX green, from the outside of E. coli into its cytoplasm. Lfcin B induced gradual leakage of calcein from large unilamellar vesicles (LUVs) of dioleoylphosphatidylglycerol (DOPG)/dioleoylphosphatidylcholine (DOPC) membranes. To clarify the cause of Lfcin B-induced leakage of calcein from the LUVs, we used the single giant unilamellar vesicle (GUV) method to investigate the interaction of Lfcin B with calcein-containing DOPG/DOPC-GUVs. We observed that a rapid leakage of calcein from a GUV started stochastically; statistical analysis provided a rate constant for Lfcin B-induced pore formation, kp. On the other hand, phase-contrast microscopic images revealed that Lfcin B induced a rapid leakage of sucrose from the single GUVs with concomitant appearance of a spherical GUV of smaller diameter. Because of the very fast leakage, and at the present time resolution of the experiments (33 ms), we could not follow the evolution of pore nor the process of the structural changes of the GUV. Here we used the term "local rupture" to express the rapid leakage of sucrose and determined the rate constant of local rupture, kL. On the basis of the comparison between kp and kL, we concluded that the leakage of calcein from single GUVs occurred as a result of a local rupture in the GUVs and that smaller pores inducing leakage of calcein were not formed before the local rupture. The results of the effect of the surface charge density of lipid membranes and that of salt concentration in buffer on kp clearly show that kp increases with an increase in the extent of electrostatic interactions due to the surface charges. Analysis of Lfcin B-induced shape changes indicated that the binding of Lfcin B increased the area of the outer monolayer of GUVs. These results indicate that Lfcin B-induced damage of the plasma membrane of E. coli with its concomitant rapid leakage of internal contents is a key factor for the bactericidal activity of LfcinB.

  1. Application of the DG-1199 methodology to the ESBWR and ABWR.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalinich, Donald A.; Gauntt, Randall O.; Walton, Fotini

    2010-09-01

    Appendix A-5 of Draft Regulatory Guide DG-1199 'Alternative Radiological Source Term for Evaluating Design Basis Accidents at Nuclear Power Reactors' provides guidance - applicable to RADTRAD MSIV leakage models - for scaling containment aerosol concentration to the expected steam dome concentration in order to preserve the simplified use of the Accident Source Term (AST) in assessing containment performance under assumed design basis accident (DBA) conditions. In this study Economic and Safe Boiling Water Reactor (ESBWR) and Advanced Boiling Water Reactor (ABWR) RADTRAD models are developed using the DG-1199, Appendix A-5 guidance. The models were run using RADTRAD v3.03. Low Populationmore » Zone (LPZ), control room (CR), and worst-case 2-hr Exclusion Area Boundary (EAB) doses were calculated and compared to the relevant accident dose criteria in 10 CFR 50.67. For the ESBWR, the dose results were all lower than the MSIV leakage doses calculated by General Electric/Hitachi (GEH) in their licensing technical report. There are no comparable ABWR MSIV leakage doses, however, it should be noted that the ABWR doses are lower than the ESBWR doses. In addition, sensitivity cases were evaluated to ascertain the influence/importance of key input parameters/features of the models.« less

  2. Natural circulating passive cooling system for nuclear reactor containment structure

    DOEpatents

    Gou, Perng-Fei; Wade, Gentry E.

    1990-01-01

    A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.

  3. Differences in Ostomy Pouch Seal Leakage Occurrences Between North American and European Residents.

    PubMed

    Fellows, Jane; Forest Lalande, Louise; Martins, Lina; Steen, Anne; Størling, Zenia M

    The purpose of this study was to compare experiences and concerns about pouch seal leakage between persons with ostomies residing in North America (Canada and the United States) and Europe (United Kingdom, Netherlands, Sweden, Germany, Belgium, France, and Italy). Differences in reported pouch wear time and accessories used between the 2 groups were also examined. Secondary analysis of data from a cross-sectional study (Ostomy Life Study). Responses from persons residing in European countries (n = 1939) were compared with responses of 1387 individuals residing in North American countries. Persons with an ostomy completed a questionnaire that focused on 4 topics related to the daily use of an ostomy pouching system (pouch seal leakage, ballooning, appearance of pouching system such as color and size of the pouch and whether it is discrete under clothing, and coupling failure of 2-piece pouching systems). Pouch seal leakage was defined as stomal effluent seeping between the skin and the wafer of the ostomy pouching system. Statistical analysis was performed using a proportional odds model including various variable effects. Special attention was given to frequency of pouch seal leakage occurrences. All tests were 2-sided; P values ≤.05 were deemed statistically significant. Participants living in the North American countries indicated they were more likely to experience leakage from the ostomy (odds ratio = 2.610, 95% CI 2.187-3.115; P < .0001). Findings also indicated they were more likely to worry about pouch seal leakage than those in the European countries' data set (odds ratio = 2.722, 95% CI 2.283-3.246; P < .0001). Participants residing in the North American countries had significantly longer wear times than those participants in the European countries (P < .0001, χ test). The use of accessories was associated with a longer pouching system wear time. Study results suggest that participants from the North American countries indicated significantly more experience with and worries about leakage and longer wear time than the participants from the European population. Additional research is needed to determine the reasons for these differences.

  4. The best time for surgery on a patient with recurrent pneumothorax and undetectable culprit lesions is at the exact time air leakage is discovered: a case report.

    PubMed

    Matsumoto, Yousuke; Hata, Yoshinobu; Makino, Takashi; Koezuka, Satoshi; Otsuka, Hajime; Sugino, Keishi; Isobe, Kazutoshi; Homma, Sakae; Iyoda, Akira

    2016-08-02

    One cause of recurrent spontaneous pneumothorax includes overlooking bullae during a previous surgery for pneumothorax; and the identification of the culprit lesions is necessary for prevention of recurrence. A 28-year-old man was referred to our hospital because of spontaneous right-sided pneumothorax. He underwent video-assisted thoracoscopic surgery, which did not reveal air leakage. The patient was subsequently seen at our hospital for 2 additional episodes of recurrent right-sided pneumothorax. At the third admission we observed intermittent air leakage while the patient was in the sitting position after chest drainage, and we performed surgery. An intraoperative submersion test showed air leakage dorsally from the pleural surface of S(6) and a minute culprit lesion, which were not seen at the first operation and confirmed the leakage site. The area was ligated and coated with regenerated oxidized cellulose mesh and autologous blood. In cases of pneumothorax with repeated recurrence, the best time to perform surgery on the patient with undetectable culprit lesion is the exact time that air leakage is observed.

  5. Randomized Controlled Trial of Hepatic Portal Reocclusion as a New Option for Detecting Bile Leakage during Hepatic Resection.

    PubMed

    Ma, Jun-Yong; Li, Xi-Feng; Yan, Zhen-Lin; Hasan, Mohammad Mahboob; Wang, Kui; Wang, Yu; Wang, Wen-Chao; Yan, Qiang; Shen, Feng; Shi, Le-Hua; Zhang, Xiao-Feng

    2017-01-01

    To explore the possibility and feasibility of hepatic portal reocclusion for detecting bile leakage during hepatectomy. Data were prospectively collected from 200 patients who underwent hepatectomy alone for removal of various benign or malignant tumors between March 2014 and November 2014. The surgical procedure used a conventional method for all patients, and one additional step (hepatic portal reocclusion) was included in group B. The postoperative outcomes of the patients in group A (subjected to the traditional procedure) and group B (subjected to hepatic portal reocclusion) were compared during the same period, and the incidence rates of postoperative bile leakage and other complications in the 2 groups were also analyzed. The incidence of postoperative bile leakage in group B was significantly lower than that in group A (1.0 vs. 9.2%, p = 0.009), although no significant differences in postoperative indicators of liver dysfunction and other complications were observed between the 2 groups (p > 0.05). Hepatic portal reocclusion effectively reduced the incidence of bile leakage compared to the traditional procedure, without significantly affecting liver function. Therefore, this method might be an alternative to other tests for bile leakage. © 2016 S. Karger AG, Basel.

  6. Determination of leakage areas in nuclear piping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keim, E.

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakagemore » areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.« less

  7. PHYSICS OF IMMISCIBLE FLOW IN POROUS MEDIA

    EPA Science Inventory

    Conceptual formulation, numerical implementation and experimental validation of a model for the movement of organic chemicals which are introduced into soils as nonaqueous phase liquids via surface spills or leakage from subsurface containment facilities were addressed. Relations...

  8. 46 CFR 38.05-1 - Design and construction of vessels-general-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of cargo tanks and piping shall have adequate notch toughness at the service temperature. Where a... sufficient notch toughness at the lowest temperature which may result during the containment of leakage cargo...

  9. Atmospheric leakage and condensate production in NASA's biomass production chamber. Effect of diurnal temperature cycles

    NASA Technical Reports Server (NTRS)

    Wheeler, Raymond M.; Drese, John H.; Sager, John C.

    1991-01-01

    A series of tests were conducted to monitor atmospheric leakage rate and condensate production in NASA's Biomass Production Chamber (BPC). Water was circulated through the 64 plant culture trays inside the chamber during the tests but no plants were present. Environmental conditions were set to a 12-hr photoperiod with either a matching 26 C (light)/20 C (dark) thermoperiod, or a constant 23 C temperature. Leakage, as determined by carbon dioxide decay rates, averaged about 9.8 percent for the 26 C/20 C regime and 7.3 percent for the constant 23 C regime. Increasing the temperature from 20 C to 26 C caused a temporary increase in pressure (up to 0.5 kPa) relative to ambient, while decreasing the temperature caused a temporary decrease in pressure of similar magnitude. Little pressure change was observed during transition between 23 C (light) and 23 C (dark). The lack of large pressure events under isothermal conditions may explain the lower leakage rate observed. When only the plant support inserts were placed in the culture trays, condensate production averaged about 37 liters per day. Placing acrylic germination covers over the tops of culture trays reduced condensate production to about 7 liters per day. During both tests, condensate production from the lower air handling system was 60 to 70 percent greater than from the upper system, suggesting imbalances exist in chilled and hot water flows for the two air handling systems. Results indicate that atmospheric leakage rates are sufficiently low to measure CO2 exchange rates by plants and the accumulation of certain volatile contaminants (e.g., ethylene). Control system changes are recommended in order to balance operational differences (e.g., humidity and temperature) between the two halves of the chamber.

  10. Correlating antimicrobial activity and model membrane leakage induced by nylon-3 polymers and detergents

    PubMed Central

    Hovakeemian, Sara G.; Liu, Runhui; Gellman, Samuel H.; Heerklotz, Heiko

    2015-01-01

    Most antimicrobial peptides act upon target microorganisms by permeabilizing their membranes. The mode of action is often assessed by vesicle leakage experiments that use model membranes, with the assumption that biological activity arises from permeabilization of the lipid bilayer. The current work aims to extend the interpretation of vesicle leakage results and examine the correlation between vesicle leakage and antimicrobial activity. To this end, we used a lifetime-based leakage assay with calcein-loaded vesicles to study the membrane permeabilizing properties of a novel antifungal polymer poly-NM, two of its analogs, and a series of detergents. In conjunction, the biological activities of these compounds against Candida albicans were assessed and correlated with data from vesicle leakage. Poly-NM induces all-or-none leakage in polar yeast lipid vesicles at the polymer’s MIC, 3 μg/mL. At this and higher concentrations, complete leakage after an initial lag time was observed. Concerted activity tests imply that this polymer acts independently of the detergent octyl glucoside (OG) for both vesicle leakage and activity against C. albicans spheroplasts. In addition, Poly-NM was found to have negligible activity against zwitterionic vesicles and red blood cells. Our results provide a consistent, detailed picture of the mode of action of Poly-NM: this polymer induces membrane leakage by electrostatic lipid clustering. In contrast, Poly-MM:CO, a nylon-3 polymer comprised of both cationic and hydrophobic segments, seems to act by a different mechanism that involves membrane asymmetry stress. Vesicle leakage for this polymer is transient (limited to <100%) and graded, non-specific among zwitterionic and polar yeast lipid vesicles, additive with detergent action, and correlates poorly with biological activity. Based on these results, we conclude that comprehensive leakage experiments can provide a detailed description of the mode of action of membrane permeabilizing compounds. Without this thorough approach, it would have been logical to assume that the two nylon-3 polymers we examined act via similar mechanisms; it is surprising that their mechanisms are so distinct. Some, but not all mechanisms of vesicle permeabilization allow for antimicrobial activity. PMID:26234884

  11. Correlating antimicrobial activity and model membrane leakage induced by nylon-3 polymers and detergents.

    PubMed

    Hovakeemian, Sara G; Liu, Runhui; Gellman, Samuel H; Heerklotz, Heiko

    2015-09-14

    Most antimicrobial peptides act upon target microorganisms by permeabilizing their membranes. The mode of action is often assessed by vesicle leakage experiments that use model membranes, with the assumption that biological activity correlates with the permeabilization of the lipid bilayer. The current work aims to extend the interpretation of vesicle leakage results and examine the correlation between vesicle leakage and antimicrobial activity. To this end, we used a lifetime-based leakage assay with calcein-loaded vesicles to study the membrane permeabilizing properties of a novel antifungal polymer poly-NM, two of its analogs, and a series of detergents. In conjunction, the biological activities of these compounds against Candida albicans were assessed and correlated with data from vesicle leakage. Poly-NM induces all-or-none leakage in polar yeast lipid vesicles at the polymer's MIC, 3 μg mL(-1). At this and higher concentrations, complete leakage after an initial lag time was observed. Concerted activity tests imply that this polymer acts independently of the detergent octyl glucoside (OG) for both vesicle leakage and activity against C. albicans spheroplasts. In addition, poly-NM was found to have negligible activity against zwitterionic vesicles and red blood cells. Our results provide a consistent, detailed picture of the mode of action of poly-NM: this polymer induces membrane leakage by electrostatic lipid clustering. In contrast, poly-MM:CO, a nylon-3 polymer comprised of both cationic and hydrophobic segments, seems to act by a different mechanism that involves membrane asymmetry stress. Vesicle leakage for this polymer is transient (limited to <100%) and graded, non-specific among zwitterionic and polar yeast lipid vesicles, additive with detergent action, and correlates poorly with biological activity. Based on these results, we conclude that comprehensive leakage experiments can provide a detailed description of the mode of action of membrane permeabilizing compounds. Without this thorough approach, it would have been logical to assume that the two nylon-3 polymers we examined act via similar mechanisms; it is surprising that their mechanisms are so distinct. Some, but not all mechanisms of vesicle permeabilization allow for antimicrobial activity.

  12. Tests of Halon 1301 test gas simulants

    NASA Astrophysics Data System (ADS)

    Carhart, H. W.; Leonard, J. T.; Dinenno, P. J.; Starchville, M. D.; Forssell, E. W.; Wong, J. T.

    1989-02-01

    All new and retrofit installations of Halon 1301 (CBrF3) total flooding fire protection systems in shipboard machinery spaces require full acceptance discharge test. It is desirable to use a suitable simulant test gas in these tests in view of current and future regulation of Halon 1301. Sulfur hexafluoride, SF6, and chlorodifluromethane R-22, were identified as candidate simulants on the basis of their similarity in physical properties to Halon 1301. These two candidates were then evaluated on the basis of leakage from an enclosure. SF6 was determined to be an excellent simulant for Halon 1301 when considering leakage from an enclosure. Further testing of SF6 and R-22 is planned for other important aspects of Halon 1301 systems, i.e., flow hydraulics, initial mixing.

  13. Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy.

    PubMed

    Marta, Gabriel Mihai; Facciolo, Francesco; Ladegaard, Lars; Dienemann, Hendrik; Csekeo, Attila; Rea, Federico; Dango, Sebastian; Spaggiari, Lorenzo; Tetens, Vilhelm; Klepetko, Walter

    2010-12-01

    Alveolar air leakage remains a serious problem in lung surgery, being associated with increased postoperative morbidity, prolonged hospital stay and greater health-care costs. The aim of this study was to evaluate the sealing efficacy and safety of the surgical patch, TachoSil®, in lung surgery. Patients undergoing elective pulmonary lobectomy who had grade 1 or 2 air leakage (evaluated by the water submersion test) after primary stapling and limited suturing were randomised at 12 European centres to open-label treatment with TachoSil® or standard surgical treatment (resuturing, stapling or no further treatment at the surgeons' discretion). Randomisation was performed during surgery using a centralised interactive voice response system. Duration of postoperative air leakage (primary end point), reduction of intra-operative air leakage intensity (secondary end point) and adverse events (AEs), including postoperative complications, were assessed. A total of 486 patients were screened and 299 received trial treatment (intent-to-treat (ITT) population: TachoSil®, n=148; standard treatment, n=151). TachoSil® resulted in a reduction in the duration of postoperative air leakage (p=0.030). Patients in the TachoSil® group also experienced a greater reduction in intra-operative air leakage intensity (p=0.042). Median time until chest drain removal was 4 days with TachoSil® and 5 days in the standard group (p=0.054). There was no difference between groups in hospital length of stay. AEs were generally similar in both groups, including postoperative complications. TachoSil® was superior to standard surgical treatment in reducing both postoperative air leakage duration and intra-operative air leakage intensity in patients undergoing elective pulmonary lobectomy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  14. A case study to detect the leakage of underground pressureless cement sewage water pipe using GPR, electrical, and chemical data.

    PubMed

    Liu, Guanqun; Jia, Yonggang; Liu, Hongjun; Qiu, Hanxue; Qiu, Dongling; Shan, Hongxian

    2002-03-01

    The exploration and determination of leakage of underground pressureless nonmetallic pipes is difficult to deal with. A comprehensive method combining Ground Penetrating Rader (GPR), electric potential survey and geochemical survey is introduced in the leakage detection of an underground pressureless nonmetallic sewage pipe in this paper. Theoretically, in the influencing scope of a leakage spot, the obvious changes of the electromagnetic properties and the physical-chemical properties of the underground media will be reflected as anomalies in GPR and electrical survey plots. The advantages of GPR and electrical survey are fast and accurate in detection of anomaly scope. In-situ analysis of the geophysical surveys can guide the geochemical survey. Then water and soil sampling and analyzing can be the evidence for judging the anomaly is caused by pipe leakage or not. On the basis of previous tests and practical surveys, the GPR waveforms, electric potential curves, contour maps, and chemical survey results are all classified into three types according to the extent or indexes of anomalies in orderto find out the leakage spots. When three survey methods all show their anomalies as type I in an anomalous spot, this spot is suspected as the most possible leakage location. Otherwise, it will be down grade suspected point. The suspect leakage spots should be confirmed by referring the site conditions because some anomalies are caused other factors. The excavation afterward proved that the method for determining the suspected location by anomaly type is effective and economic. Comprehensive method of GRP, electric potential survey, and geochemical survey is one of the effective methods in the leakage detection of underground nonmetallic pressureless pipe with its advantages of being fast and accurate.

  15. Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.

    PubMed

    Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M

    2010-10-01

    This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.

  16. Influence of cavity disinfectant and adhesive systems on the bonding procedure in demineralized dentin - a one-year in vitro evaluation.

    PubMed

    Sacramento, Patrícia A; de Castilho, Aline R; Banzi, Efani C; Puppi-Rontani, Regina Maria

    2012-12-01

    To evaluate the influence of a 2% chlorhexidine solution (CHX) on the bond strength and nano leakage of two self-etching adhesive systems on demineralized dentin over a 12-month period. The middle dentin from sound third molars was exposed and demineralized in vitro. Twelve groups were formed using different adhesive systems (Clearfil Protect Bond [PB], Clearfil SE Bond [SE]) dentin treatment (with or without CHX application), and water-storage times (24 h, 6 and 12 months). Composite resin cylinders were bonded to the prepared dentin, and these specimens underwent microshear bond strength (µSBS) testing and nano leakage evaluation. µSBS data were submitted to a three-way ANOVA and Tukey's test. The failure mode and nano leakage were analyzed descriptively by score. There was a statistically significant interaction only between the adhesive system and CHX, and adhesive system and water-storage times. SE showed the lowest µSBS just at 24 h water-storage time regardless of CHX. A significant decrease in µSBS values after 6 months of water storage occurred in all of the groups and was maintained until 12 months. Adhesive failure increased with storage time. All groups showed nano leakage at the resin/dentin interfaces and an increased silver deposition was noticed after 6 and 12 months of water storage. The highest percentages of nano leakage were found in CHX groups. CHX did not interfere with µSBS values for either self-etching adhesive system, but water storage did. Bond strength decreased for both adhesive systems after 6 and 12 months, regardless of CHX application. Nano leakage increased with water-storage time and with CHX application.

  17. Coupled modelling of groundwater flow-heat transport for assessing river-aquifer interactions

    NASA Astrophysics Data System (ADS)

    Engeler, I.; Hendricks Franssen, H. J.; Müller, R.; Stauffer, F.

    2010-05-01

    A three-dimensional finite element model for coupled variably saturated groundwater flow and heat transport was developed for the aquifer below the city of Zurich. The piezometric heads in the aquifer are strongly influenced by the river Limmat. In the model region, the river Limmat looses water to the aquifer. The river-aquifer interaction was modelled with the standard linear leakage concept. Coupling was implemented by considering temperature dependence of the hydraulic conductivity and of the leakage coefficient (via water viscosity) and density dependent transport. Calibration was performed for isothermal conditions by inverse modelling using the pilot point method. Independent model testing was carried out with help of the available dense monitoring network for piezometric heads and groundwater temperature. The model was tested by residuals analysis with the help of measurements for both groundwater temperature and head. The comparison of model results and measurements showed high accuracy for temperature except for the Southern part of the model area, where important geological heterogeneity is expected, which could not be reproduced by the model. The comparison of simulated and measured head showed that especially in the vicinity of river Limmat model results were improved by a temperature dependent leakage coefficient. Residuals were reduced up to 30% compared to isothermal leakage coefficients. This holds particularly for regions, where the river stage is considerably above the groundwater level. Furthermore additional analysis confirmed prior findings, that seepage rates during flood events cannot be reproduced with the implemented linear leakage-concept. Infiltration during flood events is larger than expected, which can be potentially attributed to additional infiltration areas. It is concluded that the temperature dependent leakage concept improves the model results for this study area significantly, and that we expect that this is also for other areas the case.

  18. 4D ERT Monitoring of Subsurface Water Pipe Leakage During a Controlled Field Experiment

    NASA Astrophysics Data System (ADS)

    Inauen, C.; Chambers, J. E.; Wilkinson, P. B.; Meldrum, P.; Swift, R. T.; Uhlemann, S.; Gunn, D.; Dashwood, B.; Taxil, J.; Curioni, G.

    2016-12-01

    Locating and delineating leakage from subsurface pipelines is an important task for civil engineers. 4D Electrical Resistivity Tomography (ERT) allows changes in subsurface resistivity to be imaged at a high spatial and temporal resolution in a minimally invasive manner. It is therefore a promising tool to supplement conventional point-sensing techniques to monitor subsurface flow processes. To assess the efficacy of ERT for pipe leakage monitoring several controlled leak experiments were carried out at a test site in Blagdon, Bristol, UK. To simulate the leak, a plastic pipe with a hole was buried below a flat, grassed area at a depth of 0.7 m, representing a standard UK mains water pipe installation. The water table at the site lies well below the surface meaning that the experiment took entirely place in the vadose zone, where changes in resistivity are primarily sensitive to water content variations. The ERT array covered an area of 6.5m x 6.5m around the leak location. Data acquisition was carried out with the BGS PRIME (Proactive Infrastructure Monitoring and Evaluation) system, which facilitates remote scheduling and autonomous ERT data collection and transmission. To obtain the resistivity changes of the subsurface a 4D inversion was carried out using a Gauss-Newton approach with spatial and temporal smoothness constraints. We were able to reliably observe the onset, spread and cessation of the leakage. Measurements from in-situ soil sensors at several depths above and below the leak complemented the ERT data and allowed us to assess their reliability and directly relate them to hydrogeological processes. Moreover, through experimental tests with soil samples from the test area, a Waxman-Smits relation was obtained to directly convert the changes in electrical resistivity to gravimetric soil moisture content. With future experiments on the test site more work is planned towards survey optimization, automated processing and tracking of leakage plumes.

  19. Relevance of Micro-leakage to Orthodontic Bonding - a Review

    PubMed Central

    M, Karandish

    2016-01-01

    As it is seen, by passing the evolutionary process of banding of orthodontic attachments to the bonding ones, orthodontics have witnessed many developments, such as application of new adhesives, optimized base designs, new bracket materials, curing methods and more efficient primers. The studies often address the morphological, micro-leakage, and shear bond tests to evaluate bond efficacy. Among studies endeavored to develop the bond strength of brackets, some observed the reduction of micro-leakage of bracket-adhesive and enamel-adhesive interfaces. Owing to the importance of micro-leakage in orthodontics, this study aimed at reviewing the micro-leakage values directly relevant to the enamel decay and debonding of the brackets. To reach the best bond strength, the researchers tried to design different studies to evaluate the effect of variables and prevent any possible side effects in clinical situations. It is noticed that most studies have mainly focused on adhesives, enamel preparation and methods of curing which are discussed in this review. The literature was reviewed by searching databases, using micro-leakage and orthodontic bonding as the keywords . Having found the relevant studies, the researchers entered them into the database. After reviewing numerous studies conducted in this field, the type of adhesive or curing method was not found to have determinative role in the value of micro-leakage although more standardized studies are needed. PMID:28959751

  20. International Space Station (ISS) Potable Water Dispenser (PWD) Beverage Adapter (BA) Redesign

    NASA Technical Reports Server (NTRS)

    Edgerly, Rachel; Benoit, Jace; Shindo, David

    2012-01-01

    The Potable Water Dispenser used on the International Space Station (ISS) interfaces with food and drink packages using the Beverage Adapter and Needle. Unexpected leakage has been seen in this interface. The Beverage Adapter used on ]orbit was returned to the ground for Test, Teardown, and Evaluation. The results of that investigation prompted a redesign of the Beverage Adapter and Needle. The Beverage Adapter materials were changed to be more corrosion resistant, and the Needle was redesigned to preclude leakage. The redesigns have been tested and proven.

  1. International Space Station (ISS) Potable Water Dispenser (PWD) Beverage Adapter (BA) Redesign

    NASA Technical Reports Server (NTRS)

    Edgerly, Rachel; Benoit, Jace; Shindo, David

    2011-01-01

    The Potable Water Dispenser used on the International Space Station (ISS) interfaces with food and drink packages using the Beverage Adapter and Needle. Unexpected leakage has been seen in this interface. The Beverage Adapter used on-orbit was returned to the ground for Test, Teardown, and Evaluation. The results of that investigation prompted a redesign of the Beverage Adapter and Needle. The Beverage Adapter materials will be changed to be more corrosion resistant, and the Needle will be redesigned to preclude leakage. The redesigns have been tested and proven.

  2. Controlled CO2 injection into a shallow aquifer and leakage detection monitoring practices at the K-COSEM site, Korea

    NASA Astrophysics Data System (ADS)

    Lee, S. S.; Joun, W.; Ju, Y. J.; Ha, S. W.; Jun, S. C.; Lee, K. K.

    2017-12-01

    Artificial carbon dioxide injection into a shallow aquifer system was performed with two injection types imitating short- and long-term CO2 leakage events into a shallow aquifer. One is pulse type leakage of CO2 (6 hours) under a natural hydraulic gradient (0.02) and the other is long-term continuous injection (30 days) under a forced hydraulic gradient (0.2). Injection and monitoring tests were performed at the K-COSEM site in Eumseong, Korea where a specially designed well field had been installed for artificial CO2 release tests. CO2-infused and tracer gases dissolved groundwater was injected through a well below groundwater table and monitoring were conducted in both saturated and unsaturated zones. Real-time monitoring data on CO2 concentration and hydrochemical parameters, and periodical measurements of several gas tracers (He, Ar, Kr, SF6) were obtained. The pulse type short-term injection test was carried out prior to the long-term injection test. Results of the short-term injection test, under natural hydraulic gradient, showed that CO2 plume migrated along the preferential pathway identified through hydraulic interference tests. On the other hand, results of the long-term injection test indicated the CO2 plume migration path was aligned to the forced hydraulic gradient. Compared to the short-term test, the long-term injection formed detectable CO2 concentration change in unsaturated wellbores. Recovery data of tracer gases made breakthrough curves compatible to numerical simulation results. The monitoring results indicated that detection of CO2 leakage into groundwater was more effectively performed by using a pumping and monitoring method in order to capture by-passing plume. With this concept, an effective real-time monitoring method was proposed. Acknowledgement: Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2storage" from the KEITI (Project number : 2014001810003)

  3. Hydrophobic drug concentration affects the acoustic susceptibility of liposomes.

    PubMed

    Nguyen, An T; Lewin, Peter A; Wrenn, Steven P

    2015-04-01

    The purpose of this study was to investigate the effect of encapsulated hydrophobic drug concentration on ultrasound-mediated leakage from liposomes. Studies have shown that membrane modifications affect the acoustic susceptibility of liposomes, likely because of changes in membrane packing. An advantage of liposome as drug carrier is its ability to encapsulate drugs of different chemistries. However, incorporation of hydrophobic molecules into the bilayer may cause changes in membrane packing, thereby affecting the release kinetics. Liposomes containing calcein and varying concentrations of papaverine, a hydrophobic drug, were exposed to 20 kHz, 2.2 Wcm(-2) ultrasound. Papaverine concentration was observed to affect calcein leakage although the effects varied widely based on liposome phase. For example, incorporation of 0.5mg/mL papaverine into Ld liposomes increased the leakage of hydrophilic encapsulants by 3× within the first minute (p=0.004) whereas the same amount of papaverine increased leakage by only 1.5× (p<0.0001). Papaverine was also encapsulated into echogenic liposomes and its concentration did not significantly affect calcein release rates, suggesting that burst release from echogenic liposomes is predictable regardless of encapsulants chemistry and concentration. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study

    PubMed Central

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    Background or Statement of Problem: As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. Aims and Objectives: To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Methodology: Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann–Whitney U-test, Kruskal–Wallis H-test and the results were statistically significant P < 0.05 the power of study - 80%. Results: Marginal leakage was significant in both provisional crowns cemented with three different luting cements along the axial walls of teeth (P < 0.05) confidence interval - 95%. Conclusion: The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage. PMID:27134427

  5. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Bosco, G; Darenbourg, B

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measuredmore » at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of the MR-Linac system studied in this work.« less

  6. Slurry wall containment performance: monitoring and modeling of unsaturated and saturated flow.

    PubMed

    Pedretti, Daniele; Masetti, Marco; Marangoni, Tomaso; Beretta, Giovanni Pietro

    2012-01-01

    A specific 2-year program to monitor and test both the vadose zone and the saturated zone, coupled with a numerical analysis, was performed to evaluate the overall performance of slurry wall systems for containment of contaminated areas. Despite local physical confinement (slurry walls keyed into an average 2-m-thick aquitard), for at least two decades, high concentrations of chlorinated solvents (up to 110 mg l(-1)) have been observed in aquifers that supply drinking water close to the city of Milan (Italy). Results of monitoring and in situ tests have been used to perform an unsaturated-saturated numerical model. These results yielded the necessary quantitative information to be used both for the determination of the hydraulic properties of the different media in the area and for the calibration and validation of the numerical model. Backfill material in the shallower part of the investigated aquifer dramatically affects the natural recharge of the encapsulated area. A transient simulation from wet to drought periods highlights a change in the ratio between leakages from lateral barriers that support a specific scenario of water loss through the containment system. The combination of monitoring and modelling allows a reliable estimate of the overall performance of the physical confinement to be made without using any invasive techniques on slurry wall.

  7. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection.

    PubMed

    Martin, Douglas J; Rad, Arash Ehteshami; Kallmes, David F

    2012-06-01

    Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, postprocedure plain radiographs, and postprocedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and prevertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ(2) test. One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34%, 95% CI 28-42%) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P = 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n = 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and prevertebral venous (n = 32, 18%, 95% CI 13-24%). Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography.

  8. Microbial ingrowth around single- and multi-component adhesives studied in vitro.

    PubMed

    Preussker, S; Klimm, W; Pöschmann, M; Koch, R

    2003-01-01

    The aim of this study was to compare the in vitro microbial leakage in 4 micro-hybrid composites in combination with 4 single-component dental adhesives (Scotchbond 1/Z100 MP = group 1; Syntac Single-Component/Tetric Flow = group 3; OptiBond Solo/XRV Herculite = group 5; Solobond M/Arabesk Top = group 7) and 4 multi-component dental adhesives (Scotchbond Multi-Purpose/Z100 MP = group 2; Syntac/Tetric Flow = group 4; OptiBond FL/XRV Herculite = group 6; Solobond Plus/Arabesk Top = group 8). Ninety-four mixed standardized Class V cavities of human caries-free extracted premolars were filled with eight different composite adhesive systems using a one-layer (groups 1-4) or a two-layer technique (groups 5-8). After thermocycling and incubation in a broth culture of Streptococcus mutans and Lactobacillus acidophilus, followed by decalcification and staining, the extent and the type of microbial leakage were measured histologically. The extent of microbial leakage in the composite restorations was very low in all groups and there were no significant differences between adhesives. Z100 MP in combination with single- and multi-component adhesives showed a significantly higher microbial leakage than Tetric Flow systems (U test: p=0.037). XRV Herculite adhesive systems showed significantly less extensive microbial leakage than Arabesk Top adhesive systems (U test: p<0.001). The single-component dental adhesives achieved a marginal adaptation of composites comparable to that of multi-component adhesives in vitro. Copyright 2003 S. Karger AG, Basel

  9. Design Study of Wafer Seals for Future Hypersonic Vehicles

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H.; Finkbeiner, Joshua R.; Steinetz, Bruce M.; DeMange, Jeffrey J.

    2005-01-01

    Future hypersonic vehicles require high temperature, dynamic seals in advanced hypersonic engines and on the vehicle airframe to seal the perimeters of movable panels, flaps, and doors. Current seals do not meet the demanding requirements of these applications, so NASA Glenn Research Center is developing improved designs to overcome these shortfalls. An advanced ceramic wafer seal design has shown promise in meeting these needs. Results from a design of experiments study performed on this seal revealed that several installation variables played a role in determining the amount of leakage past the seals. Lower leakage rates were achieved by using a tighter groove width around the seals, a higher seal preload, a tighter wafer height tolerance, and a looser groove length. During flow testing, a seal activating pressure acting behind the wafers combined with simulated vibrations to seat the seals more effectively against the sealing surface and produce lower leakage rates. A seal geometry study revealed comparable leakage for full-scale wafers with 0.125 and 0.25 in. thicknesses. For applications in which lower part counts are desired, fewer 0.25-in.-thick wafers may be able to be used in place of 0.125-in.-thick wafers while achieving similar performance. Tests performed on wafers with a rounded edge (0.5 in. radius) in contact with the sealing surface resulted in flow rates twice as high as those for wafers with a flat edge. Half-size wafers had leakage rates approximately three times higher than those for full-size wafers.

  10. Potential errors and misuse of statistics in studies on leakage in endodontics.

    PubMed

    Lucena, C; Lopez, J M; Pulgar, R; Abalos, C; Valderrama, M J

    2013-04-01

    To assess the quality of the statistical methodology used in studies of leakage in Endodontics, and to compare the results found using appropriate versus inappropriate inferential statistical methods. The search strategy used the descriptors 'root filling' 'microleakage', 'dye penetration', 'dye leakage', 'polymicrobial leakage' and 'fluid filtration' for the time interval 2001-2010 in journals within the categories 'Dentistry, Oral Surgery and Medicine' and 'Materials Science, Biomaterials' of the Journal Citation Report. All retrieved articles were reviewed to find potential pitfalls in statistical methodology that may be encountered during study design, data management or data analysis. The database included 209 papers. In all the studies reviewed, the statistical methods used were appropriate for the category attributed to the outcome variable, but in 41% of the cases, the chi-square test or parametric methods were inappropriately selected subsequently. In 2% of the papers, no statistical test was used. In 99% of cases, a statistically 'significant' or 'not significant' effect was reported as a main finding, whilst only 1% also presented an estimation of the magnitude of the effect. When the appropriate statistical methods were applied in the studies with originally inappropriate data analysis, the conclusions changed in 19% of the cases. Statistical deficiencies in leakage studies may affect their results and interpretation and might be one of the reasons for the poor agreement amongst the reported findings. Therefore, more effort should be made to standardize statistical methodology. © 2012 International Endodontic Journal.

  11. Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

    PubMed

    Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei

    2012-01-01

    Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it was verified that the method showed consistent results, and was able to determine the acceptance limit using 3σ for syringes and 6σ for vials.

  12. [Effect of carbamide peroxide bleaching agents on micro-leakage of composite resin interface in vitro].

    PubMed

    Wang, Xiao-ling; Xu, Juan; Zhao, Xin-yi; He, Hui-ming

    2011-01-01

    To evaluate the effect of carbamide peroxide (CP) bleaching agents at different concentrations and with different carriers on the micro-leakage of composite resin interface. Class V cavity (2 mm in diameter and 2 mm in depth) preparations were made at the enamelo-cemental junction on the buccal and lingual surfaces of 35 extracted human premolars. The cavities were filled with hybrid composite resin. The teeth were stored for 24 h in distilled water at 37 degrees celsius; before thermocyling for 500 times between 5 and 55 degrees celsius;. The teeth were then randomly assigned into 7 groups, and in groups 1-6, the bleaching gels containing 10% or 20% of CP were applied on the buccal and lingual surface of the teeth for two weeks (6-8 h/day, 37 degrees celsius;, 100% relative humidity) using Carbopol, PVP or Poloxamer as the thickening carriers, respectively. The seventh group served as the control without bleaching treatment. Nail polish was applied to the surface of the tooth, and all the teeth were immersed in ammoniacal silver nitrate solution followed by developing solution. The teeth were finally sectioned through the midline of the restoration and observed under stereomicroscope. SEM micrographs were also made to observe the interface. With the same bleaching agent, the micro-leakage in the gingival wall was slightly greater than in the occlusive wall, but the difference was not significant. Only 20% CP with Poloxamer as the thickening agent significantly increased the leakage of dentine-resin composite interface, and 10% and 20% CP with Carbopol or PVP as the thickening agents and 10% CP with Poloxamer produced minimal effects on filling the micro-leakage. Thickening carriers and the concentration of CP (20% or below) have no significant effect on micro-leakage of composite resin.

  13. Opposite beta2-glycoprotein I requirement for the binding of infectious and autoimmune antiphospholipid antibodies to cardiolipin liposomes is associated with antibody avidity.

    PubMed

    Celli, C M; Gharavi, A E; Chaimovich, H

    1999-01-12

    The aim of this study was to investigate the interaction of antiphospholipid antibodies (aPL) from two different populations (patients with autoimmune or infectious disorders) with cardiolipin (CL) arranged in a defined bilayer. beta2-Glycoprotein I (beta2GPI), an apolipoprotein that plays a critical role in the aPL binding to phospholipids, was quantified by dot blot in purified IgG-aPL samples, further classified according to apparent avidity to CL. In solid-phase assays, beta2GPI increased, preferentially, the binding of low-avidity autoimmune aPL to CL but inhibited the binding of low-avidity syphilitic aPL. In the absence of beta2GPI, both autoimmune and infectious aPL induced the leakage of the entrapped fluorescent probe, carboxyfluorescein (CF), from small unilamellar vesicles containing CL. aPL-induced probe leakage was protein concentration-dependent and characterized by a lag-phase onset of 100-120 min. beta2GPI increased the leakage rate induced by low-avidity autoimmune aPL only and inhibited the leakage induced by all syphilitic aPL. The following conclusions were provided: (1) in the absence of beta2GPI, autoimmune and infectious aPL bind to CL in a bilayer, inducing liposome leakage; (2) the leakage mechanism induced by aPL is suggested to be intravesicular; (3) beta2GPI requirement for phospholipid binding in both solid and fluid phase is associated to aPL avidity; (4) CL alone or the CL-beta2GPI complex are the most likely epitopes for autoimmune aPL; (5) aPL from syphilis patients can only form the CL-aPL complex, supporting that beta2GPI is not (part of) the target epitope.

  14. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    NASA Astrophysics Data System (ADS)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-06-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  15. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    NASA Technical Reports Server (NTRS)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  16. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    NASA Technical Reports Server (NTRS)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results are included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in), a fence height of 0.0635 cm (0.025 in), and 1800 bristles/cm circumference (4500 bristles/in circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approx. the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  17. Usefulness of a New Gelatin Glue Sealant System for Dural Closure in a Rat Durotomy Model

    PubMed Central

    KAWAI, Hisashi; NAKAGAWA, Ichiro; NISHIMURA, Fumihiko; MOTOYAMA, Yasushi; PARK, Young-Su; NAKAMURA, Mitsutoshi; NAKASE, Hiroyuki; SUZUKI, Shuko; IKADA, Yoshito

    2014-01-01

    Watertight dural closure is imperative after neurosurgical procedures, because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. We used a rat durotomy model to test the usefulness of a new gelatin glue as a dural sealant in a rat model of transdural CSF leakage. All rats were randomly divided into one of the following three treatment groups: no application (control group: N = 18), application of fibrin glue (fibrin glue group: N = 18), and application of the new gelatin glue (new gelatin glue group: N = 18). The craniotomy side was re-opened, and CSF leakage was checked and recorded at 1, 7, and 28 days postoperatively. The new gelatin glue was adequate for stopping CSF leakage; no leakage was observed at postoperative days 1 or 7, and leakage was observed in only one rat at postoperative day 28. This result was statistically significant when compared to the control group (P = 0.002, P = 0.015, P = 0.015, respectively). The pathologic score of the new gelatin group was not different from that of the control or fibrin glue groups. We conclude that our new gelatin glue provides effective watertight closure 1, 7, and 28 days after operation in the rat durotomy model. PMID:25070015

  18. Alternative magnetic flux leakage modalities for pipeline inspection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katragadda, G.; Lord, W.; Sun, Y.S.

    1996-05-01

    Increasing quality consciousness is placing higher demands on the accuracy and reliability of inspection systems used in defect detection and characterization. Nondestructive testing techniques often rely on using multi-transducer approaches to obtain greater defect sensitivity. This paper investigates the possibility of taking advantage of alternative modalities associated with the standard magnetic flux leakage tool to obtain additional defect information, while still using a single excitation source.

  19. Cancellation Circuit for Transmit-Receive Isolation

    DTIC Science & Technology

    2010-09-01

    non -ideal hardware, and the performance of the circuit is limited. One of the major problems is the leakage from the circulator. The leakage disrupts...cancellation circuit was investigated by a series of simulations using Agilent ADS (Agilent Advanced Design System), and hardware tests were conducted to...developed in the WDDPA application, allowing coherent processing of the data from all elements. There are limitations encountered due to non -ideal

  20. Electronically controlled mechanical seal for aerospace applications--Part 2: Transient tests

    NASA Technical Reports Server (NTRS)

    Wolff, Paul J.; Salant, Richard F.

    1995-01-01

    An electronically controlled mechanical seal for use as the purge gas seal in a liquid oxygen turbopump has been fabricated and tested under transient operating conditions. The thickness of the lubricating film is controlled by adjusting the coning of the carbon face. This is accomplished by applying a voltage to a piezoelectric actuator to which the carbon face is bonded. The seal has been operated with a closed-loop control system that utilizes either the leakage rate or seal face temperature as the feedback. Both speed and pressure transients have been imposed on the seal. The transient tests have demonstrated that the seal is capable of maintaing low leakage rates while limiting face temperatures.

  1. Effects of boundary-layer separation controllers on a desktop fume hood.

    PubMed

    Huang, Rong Fung; Chen, Jia-Kun; Hsu, Ching Min; Hung, Shuo-Fu

    2016-10-02

    A desktop fume hood installed with an innovative design of flow boundary-layer separation controllers on the leading edges of the side plates, work surface, and corners was developed and characterized for its flow and containment leakage characteristics. The geometric features of the developed desktop fume hood included a rearward offset suction slot, two side plates, two side-plate boundary-layer separation controllers on the leading edges of the side plates, a slanted surface on the leading edge of the work surface, and two small triangular plates on the upper left and right corners of the hood face. The flow characteristics were examined using the laser-assisted smoke flow visualization technique. The containment leakages were measured by the tracer gas (sulphur hexafluoride) detection method on the hood face plane with a mannequin installed in front of the hood. The results of flow visualization showed that the smoke dispersions induced by the boundary-layer separations on the leading edges of the side plates and work surface, as well as the three-dimensional complex flows on the upper-left and -right corners of the hood face, were effectively alleviated by the boundary-layer separation controllers. The results of the tracer gas detection method with a mannequin standing in front of the hood showed that the leakage levels were negligibly small (≤0.003 ppm) at low face velocities (≥0.19 m/s).

  2. Validation of an instrument to assess barriers to care-seeking for accidental bowel leakage in women: the BCABL questionnaire

    PubMed Central

    Brown, Heidi Wendell; Wise, Meg E.; Westenberg, Danielle; Schmuhl, Nicholas B.; Brezoczky, Kelly Lewis; Rogers, Rebecca G.; Constantine, Melissa L.

    2017-01-01

    Introduction and hypothesis Fewer than 30% of women with accidental bowel leakage (ABL) seek care, despite the existence of effective, minimally invasive therapies. We developed and validated a condition-specific instrument to assess barriers to care-seeking for ABL in women. Methods Adult women with ABL completed an electronic survey about condition severity, patient activation, previous care-seeking, and demographics. The Barriers to Care-seeking for Accidental Bowel Leakage (BCABL) instrument contained 42 potential items completed at baseline and again 2 weeks later. Paired t tests evaluated test–retest reliability. Factor analysis evaluated factor structure and guided item retention. Cronbach’s alpha evaluated internal consistency. Within and across factor item means generated a summary BCABL score used to evaluate scale validity with six external criterion measures. Results Among 1,677 click-throughs, 736 (44%) entered the survey; 95% of eligible female respondents (427 out of 458) provided complete data. Fifty-three percent of respondents had previously sought care for their ABL; median age was 62 years (range 27–89); mean Vaizey score was 12.8 (SD = 5.0), indicating moderate to severe ABL. Test–retest reliability was excellent for all items. Factor extraction via oblique rotation resulted in the final structure of 16 items in six domains, within which internal consistency was high. All six external criterion measures correlated significantly with BCABL score. Conclusions The BCABL questionnaire, with 16 items mapping to six domains, has excellent criterion validity and test–retest reliability when administered electronically in women with ABL. The BCABL can be used to identify care-seeking barriers for ABL in different populations, inform targeted interventions, and measure their effectiveness. PMID:28236039

  3. Theory versus experiment for the rotordynamic coefficients of annular gas seals. I - Test facility and apparatus

    NASA Technical Reports Server (NTRS)

    Childs, D. W.; Nelson, C. E.; Nicks, C.; Scharrer, J.; Elrod, D.

    1985-01-01

    A facility and apparatus are described for determining the rotordynamic coefficients and leakage characteristics of annular gas seals. The coefficients and leakage characteristics of annular gas seals. The apparatus has a current top speed of 8000 cpm with a nominal seal diameter of 15.24 cmn (6 in.). The air supply unit yields a seal pressure ratio of approximately 7. An external shaker is used to excite the test rotor. The capability to independently calculate all rotordynamic coefficients at a given operating condition with one excitation frequency are discussed.

  4. 49 CFR 179.300-16 - Tests of tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... air pressure test of at least 100 psig under conditions favorable to detection of any leakage. No... postweld heat treatment, tanks shall be subjected to hydrostatic expansion test in a water jacket, or by...

  5. 14 CFR Appendix E to Part 43 - Altimeter System Test and Inspection

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... (v) Case leak. The leakage of the altimeter case, when the pressure within it corresponds to an...) Automatic Pressure Altitude Reporting Equipment and ATC Transponder System Integration Test. The test must...

  6. 14 CFR Appendix E to Part 43 - Altimeter System Test and Inspection

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... (v) Case leak. The leakage of the altimeter case, when the pressure within it corresponds to an...) Automatic Pressure Altitude Reporting Equipment and ATC Transponder System Integration Test. The test must...

  7. 14 CFR Appendix E to Part 43 - Altimeter System Test and Inspection

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... (v) Case leak. The leakage of the altimeter case, when the pressure within it corresponds to an...) Automatic Pressure Altitude Reporting Equipment and ATC Transponder System Integration Test. The test must...

  8. High-Speed, High-Temperature Finger Seal Test Evaluated

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.

    2003-01-01

    A finger seal, designed and fabricated by Honeywell Engines, Systems and Services, was tested at the NASA Glenn Research Center at surface speeds up to 1200 ft/s, air temperatures up to 1200 F, and pressures across the seal of 75 psid. These are the first test results obtained with NASA s new High-Temperature, High-Speed Turbine Seal Test Rig (see the photograph). The finger seal is an innovative design recently patented by AlliedSignal Engines, which has demonstrated considerably lower leakage than commonly used labyrinth seals and is considerably cheaper than brush seals. The cost to produce finger seals is estimated to be about half of the cost to produce brush seals. Replacing labyrinth seals with fingers seals at locations that have high-pressure drops in gas turbine engines, typically main engine and thrust seals, can reduce air leakage at each location by 50 percent or more. This directly results in a 0.7- to 1.4-percent reduction in specific fuel consumption and a 0.35- to 0.7-percent reduction in direct operating costs . Because the finger seal is a contacting seal, this testing was conducted to address concerns about its heat generation and life capability at the higher speeds and temperatures required for advanced engines. The test results showed that the seal leakage and wear performance are acceptable for advanced engines.

  9. Geological and geophysical investigation of water leakage from two micro-dam reservoirs: Implications for future site selection, northern Ethiopia

    NASA Astrophysics Data System (ADS)

    Berhane, Gebremedhin; Amare, Mogos; Gebreyohannes, Tesfamichael; Walraevens, Kristine

    2017-05-01

    Water resources are essential to human development activities and to eradicate extreme poverty and hunger. Geological problems of two water harvesting Micro-Dam Reservoirs (MDRs) were evaluated from leakage perspectives in the northern part of Ethiopia, East Africa. Conventional geological mapping, discontinuity and weathering descriptions, test pits and geophysical methods were used to characterize the hydrogeological features of the MDRs. Vertical Electrical Sounding (VES) and Electrical Profiling (EP), were executed using Terrameter SAS (signal averaging system) 1000 manufactured by ABEM, Sweden, with Schlumberger and Wenner array configuration respectively. It was concluded that the foundations of both MDRs, except the right abutment for Adishuhu which is partly composed of dolerite, are pervious due to the presence of thin bedding planes, joints, weathered materials and fault. The presence of water in the downstream toe of the MDRs, at depressions, existing test pits and test pits excavated during the present study which lie within the seepage zone demarcated during surface geological mapping, correspond with the electrical resistivity study. The results of the electrical resistivity survey (EP and VES) were merged with the geological and structural mapping and the observation of seepage zones, for the delineation of weak zones responsible for leakage. Monitoring of the leakage (reservoir water and groundwater levels), both manually and using automatic divers, is recommended, along with monitoring of the stability of the embankments and the discharge or flow downstream of the MDRs.

  10. Interpretation of discrepancies in mass spectroscopy data obtained from different experimental configurations

    NASA Technical Reports Server (NTRS)

    Russell, John M.

    1993-01-01

    Many helium mass spectrometer leak detectors at KSC employ sampling systems that feature hand held sniffer probes. Authors of general leakage-testing literature recommend sniffer probes for leak location but not for quantitative leakage measurement. Their use in the latter application at KSC involves assumptions that may be subtle. The purpose of the research effort reported herein was to establish the significance of indicated leak rates displayed by sniffer-probe equipped leak detectors and to determine whether the use of alternative hardware or testing procedures may reduce the uncertainty of leakage measurements made with them. The report classifies probe-type sampling systems for helium leak detectors according to their internal plumbing (direct or branched), presents a basic analysis of the fluid dynamics in the sampling system in the branched-conduit case, describes the usual test method for measuring the internal supply-to-sample flowrate ratio (a.k.a permeation ratio), and describes a concept for a sponge-tipped probe whose external supply-to-sample flowrate ratio promises to be lower than that of a simple-ended probe. One conclusion is that the main source of uncertainty in the use of probe-type sampling systems for leakage measurement is uncertainty in the external supply-to-sample flowrate ratio. In contrast, the present method for measuring the internal supply-to-sample flowrate ratio is quantitative and satisfactory. The implication is that probes of lower external supply-to-sample flowrate ratio must be developed before this uncertainty may be reduced significantly.

  11. 40 CFR 418.51 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.51 Specialized... chemicals but which may on the occasion of corrosion, cooling system leakage or similar cooling system failures contain small amounts of process chemicals: Provided, That all reasonable measures have been taken...

  12. 40 CFR 418.51 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.51 Specialized... chemicals but which may on the occasion of corrosion, cooling system leakage or similar cooling system failures contain small amounts of process chemicals: Provided, That all reasonable measures have been taken...

  13. 40 CFR 418.51 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.51 Specialized... chemicals but which may on the occasion of corrosion, cooling system leakage or similar cooling system failures contain small amounts of process chemicals: Provided, That all reasonable measures have been taken...

  14. 40 CFR 418.51 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.51 Specialized... chemicals but which may on the occasion of corrosion, cooling system leakage or similar cooling system failures contain small amounts of process chemicals: Provided, That all reasonable measures have been taken...

  15. 40 CFR 418.51 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AND STANDARDS FERTILIZER MANUFACTURING POINT SOURCE CATEGORY Nitric Acid Subcategory § 418.51... chemicals but which may on the occasion of corrosion, cooling system leakage or similar cooling system failures contain small amounts of process chemicals: Provided, That all reasonable measures have been taken...

  16. 49 CFR 175.78 - Stowage compatibility of cargo.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... leakage. (b) At a minimum, the segregation instructions prescribed in the following Segregation Table must be followed to maintain acceptable segregation between packages containing hazardous materials with different hazards. The Segregation Table instructions apply whether or not the class or division is the...

  17. A concept of dynamic permission mechanism on android

    NASA Astrophysics Data System (ADS)

    Aron, Lukas; Hanacek, Petr

    2016-02-01

    This paper discuss the main security topic in mobile security area and this topic is protect user against the leakage of data. This work primarily contains the proposal of concept of dynamic permission mechanism for Android operating system. This mechanism deals with assignment or enforcement permissions to the application according to files that the application works with. Application has set of permissions that can use, but if the user opens confident files the application permissions should change its permission set and there should not be possible leakage of this secret data. The permissions set should be stricter according to opened confidential file or more open (without restriction) if the file is not secret file. The concept proposes the solution for protecting this data leakage. Idea covers rule that user should be avoided of change this permissions himself, but this behavior should be dynamic, automatic and independent. This proposal is mainly aimed to Android operating system, but the concept can be applied to other mobile platforms with some implementation changes.

  18. Cyclic tests of P-bulb end-seal designs for a shuttle-type wing-elevon cove membrane seal

    NASA Technical Reports Server (NTRS)

    Hunt, L. R.

    1979-01-01

    Four P-bulb end seal designs were tested at room temperature in a cyclic seal test apparatus. Test results show that all the P-bulb end seals have the durability required for a 100 mission life (neglecting possible elevated-temperature effects) and three of the four P-bulbs provide an adequate seal against a 7.0-kPa air pressure differential. Antifriction material attached to the P-bulb rub surface reduced friction slightly but could degrade the sealing effectiveness. A flat rub surface molded into the P-bulb discouraged wrinkling and rolling and thereby reduced leakage. However, the P-bulbs lacked resilience, as indicated by increased leakage when P-bulb compression was reduced. The best P-bulb design tested included an antifriction interface bonded to a flat surface molded into the P-bulb.

  19. Prophylactic transanal decompression tube versus non-prophylactic transanal decompression tube for anastomotic leakage prevention in low anterior resection for rectal cancer: a meta-analysis.

    PubMed

    Yang, Yun; Shu, Ye; Su, Fangyu; Xia, Lin; Duan, Baofeng; Wu, Xiaoting

    2017-04-01

    Transanal decompression tube (TDT), an alternative intervention believed to have potential equivalent efficacy in reducing anastomotic leakage after rectal cancer surgery and lower complication rates compared to protective stoma, was sporadically applied in some medical centers during recent decade. The objective of this meta-analysis was to evaluate the effect of the TDT in preventing the anastomotic leakage after low anterior resection for rectal cancer. The studies comparing TDT and non-TDT in rectal cancer were researched up to March 22, 2016 without language preference, in databases of PubMed, Web of Science, Cochrane library, International Clinical Trials Registry Platform, and National Clinical Trials Registry. The rates of anastomotic leakage, bleeding, and re-operation were separately calculated and compared between TDT and non-TDT groups using RevMan 5.3. Funnel plots, and Egger's tests were used to evaluate the publication biases of the studies. Two prospective randomized controlled trial studies and five observational cohort studies with 833 participants in TDT group and 939 participants in non-TDT group were finally included in this meta-analysis. The results indicated that the TDT group had lower anastomotic leakage rate than non-TDT group with significant RR (RR 0.44; 95 % CI 0.29-0.66; P < 0.0001) and heterogeneity (I 2  = 33 %; P = 0.18). So did the re-operation rate, with RR (RR 0.16; 95 % CI 0.07-0.37; P < 0.0001) and heterogeneity among the studies (I 2  = 0 %; P = 0.80). There was no significant difference in anastomotic bleeding rates (RR 1.48; 95 % CI 0.79-2.77; P = 0.22) (I 2  = 58 %; P = 0.09). No publication bias was found by Egger's test (anastomotic leakage rate, Pr > |z| = 0.224; re-operation rate, Pr > |z| = 0.425). TDT might be an efficient and economic intervention in preventing anastomotic leakage after rectal cancer surgery.

  20. Detecting fluid leakage of a reservoir dam based on streaming self-potential measurements

    NASA Astrophysics Data System (ADS)

    Song, Seo Young; Kim, Bitnarae; Nam, Myung Jin; Lim, Sung Keun

    2015-04-01

    Between many reservoir dams for agriculture in suburban area of South Korea, water leakage has been reported several times. The dam under consideration in this study, which is located in Gyeong-buk, in the south-east of the Korean Peninsula, was reported to have a large leakage at the right foot of downstream side of the reservoir dam. For the detection of the leakage, not only geological survey but also geophysical explorations have been made for precision safety diagnosis, since the leakage can lead to dam failure. Geophysical exploration includes both electrical-resistivity and self-potential surveys, while geological surveys water permeability test, standard penetration test, and sampling for undisturbed sample during the course of the drilling investigation. The geophysical explorations were made not only along the top of dam but also transverse the heel of dam. The leakage of water installations can change the known-heterogeneous structure of the dam body but also cause streaming spontaneous (self) potential (SP) anomaly, which can be detected by electrical resistivity and SP measurements, respectively. For the interpretation of streaming SP, we used trial-and-error method by comparing synthetic SP data with field SP data for model update. For the computation, we first invert the resistivity data to obtain the distorted resistivity structure of the dam levee then make three-dimensional electrical-resistivity modeling for the streaming potential distribution of the dam levee. Our simulation algorithm of streaming SP distribution based on the integrated finite difference scheme computes two-dimensional (2D) SP distribution based on the distribution of calculated flow velocities of fluid for a given permeability structure together with physical properties. This permeability is repeatedly updated based on error between synthetic and field SP data, until the synthetic data match the field data. Through this trial-and-error-based SP interpretation, we locate the leakage of reservoir-water formed locally inside the levee body of the reservoir dam within the limitation due to the 2D nature of stream SP simulation.

  1. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    PubMed

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  2. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    PubMed Central

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability. PMID:23710141

  3. On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vadivel, Nicole R.; Ha, Seungbum; He, Meinan

    2017-01-01

    In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramicmore » (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.« less

  4. High-Speed, High-Temperature Finger Seal Test Results

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Kumar, Arun; Delgado, Irebert R.

    2002-01-01

    Finger seals have significantly lower leakage rates than conventional labyrinth seals used in gas turbine engines and are expected to decrease specific fuel consumption by over 1 percent and to decrease direct operating cost by over 0.5 percent. Their compliant design accommodates shaft growth and motion due to thermal and dynamic loads with minimal wear. The cost to fabricate these finger seals is estimated to be about half the cost to fabricate brush seals. A finger seal has been tested in NASA's High Temperature, High Speed Turbine Seal Test Rig at operating conditions up to 1200 F, 1200 ft/s, and 75 psid. Static, performance and endurance test results are presented. While seal leakage and wear performance are acceptable, further design improvements are needed to reduce the seal power loss.

  5. Experimental assessment of advanced Stirling component concepts

    NASA Technical Reports Server (NTRS)

    Ziph, B.

    1985-01-01

    The results of an experimental assessment of some advanced Stirling engine component concepts are presented. High performance piston rings, reciprocating oil scrapers and heat pipes with getters and with mechanical couplings were tested. The tests yielded the following results: (1) Bonded, split, pumping piston rings, in preliminary testing, proved a promising concept, exhibiting low leakage and friction losses. Solid piston rings proved impractical in view of their sensitivity to the operating temperature; (2) A babbit oil scraper in a compliant housing performed well in atmospheric endurance testing. In pressurized tests the scraper did not perform well as a containment seal. The latter tests suggest modifications which may adapt Ti successfully to that application; and (3) Heat pipe endurance tests indicated the adequacy of simple, inexpensive fabrication and filling procedures. Getters were provided to increase the tolerance of the heat pipes to the presence of air and commercially available couplings were demonstrated to be suitable for heat pipe application. In addition to the above tests, the program also included a design effort for a split shaft applicable to a swashplate driven engine with a pressurized crank-case. The design is aimed, and does accomplish, an increase in component life to more than 10,000 hours.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roos, E.; Maier, V.; Nagel, G.

    The break preclusion concept is based on {open_quotes}KTA rules{close_quotes}, {open_quotes}RSK guidelines{close_quotes} and {open_quotes}Rahmenspeziflkation Basissicherheit{close_quotes}. These fundamental rules containing for example requirements on material, design, calculation, manufacturing and testing procedures are explained and the technical realisation is shown by means of examples. The proof of the quality of these piping systems can be executed by means of fracture mechanics calculations by showing that in every case the leakage monitoring system already detect cracks which are clearly smaller than the critical crack. Thus the leak before break behavior and the break preclusion concept is implicitly affirmed. In order to further diminish conservativitiesmore » in the fracture mechanics procedures, specific research projects are executed which are explained in this contribution.« less

  7. Cross-Talk in Superconducting Transmon Quantum Computing Architecture

    NASA Astrophysics Data System (ADS)

    Abraham, David; Chow, Jerry; Corcoles, Antonio; Rothwell, Mary; Keefe, George; Gambetta, Jay; Steffen, Matthias; IBM Quantum Computing Team

    2013-03-01

    Superconducting transmon quantum computing test structures often exhibit significant undesired cross-talk. For experiments with only a handful of qubits this cross-talk can be quantified and understood, and therefore corrected. As quantum computing circuits become more complex, and thereby contain increasing numbers of qubits and resonators, it becomes more vital that the inadvertent coupling between these elements is minimized. The task of accurately controlling each single qubit to the level of precision required throughout the realization of a quantum algorithm is difficult by itself, but coupled with the need of nulling out leakage signals from neighboring qubits or resonators would quickly become impossible. We discuss an approach to solve this critical problem. We acknowledge support from IARPA under contract W911NF-10-1-0324.

  8. 49 CFR 195.304 - Test pressure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Test pressure. 195.304 Section 195.304... PIPELINE Pressure Testing § 195.304 Test pressure. The test pressure for each pressure test conducted under... case of a pipeline that is not visually inspected for leakage during the test, for at least an...

  9. Aberrant Wound-Healing Response in Mitomycin C-Treated Leaking Blebs: A Histopathologic Study

    PubMed Central

    Elner, Victor M.; Newman-Casey, Paula Anne; Patil, A. Jayaprakash; Flint, Andrew; Biswas, Jyotirmay; Moroi, Sayoko E.; Pushparaj, Vaijayanthi; Edward, Deepak P.

    2014-01-01

    Objective To characterize histopathologic features of leaking mitomycin-C-treated blebs and aberrant wound healing that may lead to persistent conjunctival thinning and leakage. Methods Forty mitomycin C-treated filtering blebs excised for persistent leaks from 40 patients were examined histopathologically using hematoxylin-eosin, periodic acid-Schiff, Masson trichrome, and Alcian blue histochemical stains. Results Ninety percent of the leaking blebs contained epithelial-stromal domes with areas of acellular stroma covered by attenuated epithelium. Seventy-five percent of the blebs demonstrated varying degrees of fibrovascular repair growing from the bleb margin, either beneath or interdigitating with the acellular zone. A novel observation in 65% of specimens was Alcian blue-positive myxoid stroma at the interface between the fibrovascular proliferation and the epithelial-stromal dome. The association between the presence of fibrovascular proliferation and Alcian-blue staining myxoid stroma was significant by Fisher exact test (P=0.002). Conclusions A desirable filtration bleb requires a sufficient reparative fibrovascular response to maintain an epithelial-stromal barrier in order to prevent leakage. Fibroblasts must lay down a continuous collagen-rich fibrous layer, rather than merely myxoid stroma, beneath the conjunctival epithelium to promote bleb stability. Surgical techniques and postsurgical care should aim to attain this desired outcome. PMID:19667341

  10. Glycyl-alanyl-histidine protects PC12 cells against hydrogen peroxide toxicity.

    PubMed

    Shimura, Hideki; Tanaka, Ryota; Shimada, Yoshiaki; Yamashiro, Kazuo; Hattori, Nobutaka; Urabe, Takao

    2017-11-22

    Peptides with cytoprotective functions, including antioxidants and anti-infectives, could be useful therapeutics. Carnosine, β-alanine-histidine, is a dipeptide with anti-oxidant properties. Tripeptides of Ala-His-Lys, Pro-His-His, or Tyr-His-Tyr are also of interest in this respect. We synthesized several histidine-containing peptides including glycine or alanine, and tested their cytoprotective effects on hydrogen peroxide toxicity for PC12 cells. Of all these peptides (Gly-His-His, Ala-His-His, Ala-His-Ala, Ala-Ala-His, Ala-Gly-His, Gly-Ala-His (GAH), Ala-His-Gly, His-Ala-Gly, His-His-His, Gly-His-Ala, and Gly-Gly-His), GAH was found to have the strongest cytoprotective activity. GAH decreased lactate dehydrogenase (LDH) leakage, apoptosis, morphological changes, and nuclear membrane permeability changes against hydrogen peroxide toxicity in PC12 cells. The cytoprotective activity of GAH was superior to that of carnosine against hydrogen peroxide toxicity in PC12 cells. GAH also protected PC12 cells against damage caused by actinomycin D and staurosporine. Additionally, it was found that GAH also protected SH-SY5Y and Jurkat cells from damage caused by hydrogen peroxide, as assessed by LDH leakage. Thus, a novel tripeptide, GAH, has been identified as having broad cytoprotective effects against hydrogen peroxide-induced cell damage.

  11. A new polymer nanocomposite repair material for restoring wellbore seal integrity

    DOE PAGES

    Genedy, Moneeb; Kandil, Usama F.; Matteo, Edward N.; ...

    2017-03-01

    Seal integrity of functional oil wells and abandoned wellbores used for CO 2 subsequent storage has become of significant interest with the oil and gas leaks worldwide. This is attributed to the fact that wellbores intersecting geographical formations contain potential leakage pathways. One of the critical leakage pathways is the cement-shale interface. In this study, we examine the efficiency of a new polymer nanocomposite repair material that can be injected for sealing micro annulus in wellbores. The bond strength and microstructure of the interface of Type G oil well cement (reference), microfine cement, Novolac epoxy incorporating Neat, 0.25%, 0.5%, andmore » 1.0% Aluminum Nanoparticles (ANPs) with shale is investigated. Interfacial bond strength testing shows that injected microfine cement repair has considerably low bond strength, while ANPs-epoxy nanocomposites have a bond strength that is an order of magnitude higher than cement. Microscopic investigations of the interface show that micro annulus interfacial cracks with widths up to 40 μm were observed at the cement-shale interface while these cracks were absent at the cement-epoxy-shale interface. Finally, Fourier Transform Infrared and Dynamic mechanical analysis measurements showed that ANPs improve interfacial bond by limiting epoxy crosslinking, and therefore allowing epoxy to form robust bonds with cement and shale.« less

  12. The effect of endodontic materials on the optical density of dyes used in marginal leakage studies.

    PubMed

    Kubo, Claudio Hideki; Valera, Marcia Carneiro; Gomes, Ana Paula Martins; Mancini, Maria Nadir Gasparoto; Camargo, Carlos Henrique Ribeiro

    2008-01-01

    The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.

  13. Extending the shelf life of edible flowers with controlled release of 1-methylcyclopropene and modified atmosphere packaging.

    PubMed

    Kou, Liping; Turner, Ellen R; Luo, Yaguang

    2012-05-01

    Edible flowers have great sensory appeal, but their extremely short shelf life limits their commercial usage. Postharvest 1-methylcyclopropene (1-MCP) treatment is used to counter ethylene activity and delay senescence in fresh produce; however, its potential application in edible flowers has not been tested. The objective of this study was to investigate the effect of 1-MCP treatment with modified atmosphere packaging (MAP) on the shelf life of edible flowers. Freshly harvested carnations and snapdragons were packaged in trays with or without 0.5 μL/L of 1-MCP, sealed with a gas permeable film, and stored at 5 °C. Package atmospheres, tissue electrolyte leakage, and flower quality were evaluated on days 0, 7, and 14. Treatment with 1-MCP resulted in significantly slower changes in package headspace O(2), CO(2), and C(2)H(4) partial pressures, maintained higher overall quality of both flower species and reduced electrolyte leakage and abscission in snapdragon. All samples prepared with MAP had significantly reduced dehydration and higher overall quality compared to flowers packaged commercially in plastic clamshell containers. Treatments with controlled release of 1-MCP and MAP significantly extended storage life of edible carnation and snapdragon flowers. © 2012 Institute of Food Technologists®

  14. Utility of human hepatocyte spheroids without feeder cells for evaluation of hepatotoxicity.

    PubMed

    Ogihara, Takuo; Arakawa, Hiroshi; Jomura, Tomoko; Idota, Yoko; Koyama, Satoshi; Yano, Kentaro; Kojima, Hajime

    2017-01-01

    We investigated the utility of three-dimensionally cultured hepatocytes (spheroids) without feeder cells (Sph(f-)) for the prediction of drug-induced liver injury (DILI) in humans. Sph(f-) and spheroids cultured on feeder cells (Sph(f+)) were exposed to the hepatotoxic drugs flutamide, diclofenac, isoniazid and chlorpromazine at various concentrations for 14 days, and albumin secretion and cumulative leakages of toxicity marker enzymes, aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH) and γ-glutamyl transpeptidase (γ-GTP), were measured. The cumulative AST, LDH or γ-GTP leakages from Sph(f-) were similar to or greater than those from Sph(f+) for all drugs tested, although ALT leakages showed no consistent difference between Sph(f+) and Sph(f-). In the case of Sph(f-), significant correlations among all the toxicity markers except for γ-GTP were observed. As regards the drug concentrations causing 1.2-fold elevation of enzyme leakage (F 1.2 ), no consistent difference between Sph(f+) and Sph(f-) was found, although several F 1.2 values were undetermined, especially in Sph(f+). The IC 50 of albumin secretion and F 1.2 of AST leakage from Sph(f-) were equal to or lower than those of Sph(f+) for all the tested drugs. These results indicate that feeder cells might contribute to resistance to hepatotoxicity, suggesting DILI could be evaluated more accurately by using Sph(f-). We suggest that long-term exposure of Sph(f-) to drugs might be a versatile method to predict and reproduce clinical chronic toxicity, especially in response to repeated drug administration.

  15. Development of spiral-groove self-acting face seals

    NASA Technical Reports Server (NTRS)

    Obrien, M.

    1977-01-01

    An experimental evaluation and a 100-hour endurance test were performed on a spiral groove geometry, self-acting face seal. The seal was tested and operated successfully at maximum conditions of 243.8 m/s surface speed, 199.9 N/sq cm air pressure, and 645.4K (702 F) air temperature. The maximum speed condition of 243.8 m/s was obtained at a shaft speed of 72,500 rpm. Seal wear, gas leakage, and sealing element temperature were monitored during the test. Condition of the seal at the completion of the test was documented and found acceptable for further use. The spiral groove wear rate measured during the endurance test indicates a minimum potential seal life of over 2700 hours. Seal air leakage measured during the test program is within the range considered acceptable for consideration for use in a small gas turbine engine.

  16. Design of a Vertical Composite Thin Film System with Ultralow Leakage To Yield Large Converse Magnetoelectric Effect.

    PubMed

    Wu, Rui; Kursumovic, Ahmed; Gao, Xingyao; Yun, Chao; Vickers, Mary E; Wang, Haiyan; Cho, Seungho; MacManus-Driscoll, Judith L

    2018-05-30

    Electric field control of magnetism is a critical future technology for low-power, ultrahigh density memory. However, despite intensive research efforts, no practical material systems have emerged. Interface-coupled, composite systems containing ferroelectric and ferri-/ferromagnetic elements have been widely explored, but they have a range of problems, for example, substrate clamping, large leakage, and inability to miniaturize. In this work, through careful material selection, design, and nanoengineering, a high-performance room-temperature magnetoelectric system is demonstrated. The clamping problem is overcome by using a vertically aligned nanocomposite structure in which the strain coupling is independent of the substrate. To overcome the leakage problem, three key novel advances are introduced: a low leakage ferroelectric, Na 0.5 Bi 0.5 TiO 3 ; ferroelectric-ferrimagnetic vertical interfaces which are not conducting; and current blockage via a rectifying interface between the film and the Nb-doped SrTiO 3 substrate. The new multiferroic nanocomposite (Na 0.5 Bi 0.5 TiO 3 -CoFe 2 O 4 ) thin-film system enables, for the first time, large-scale in situ electric field control of magnetic anisotropy at room temperature in a system applicable for magnetoelectric random access memory, with a magnetoelectric coefficient of 1.25 × 10 -9 s m -1 .

  17. Assessment of Coronal Leakage of Temporary Restorations in Root Canal-treated Teeth: An in vitro Study.

    PubMed

    Srivastava, Pankaj K; Nagpal, Ajay; Setya, Gaurav; Kumar, Sunil; Chaudhary, Alankrita; Dhanker, Kuldeep

    2017-02-01

    Coronal leakage is one of the constant concerns in routine dental practice. It is one of the factors responsible for the failure of root canal therapy. Permanent restorations should be given as soon as possible after the completion of root canal therapy. If unavoidable, provisional restoration should be given in such a way that it maximally reduced the leakage of microorganisms and fluids from the external environment into the canal space. Hence, we evaluated the effect of saliva on the coronal leakage of temporary restorations. Biomechanical preparation of the root canals of 204 fresh mandibular first premolar teeth was done using endodontic files with intermittent irrigation of sodium hypochlorite solution and ethylenediaminetetraacetic acid. Alternate irrigation with normal saline was done periodically. After preparation, drying of the canals was done using paper points followed by sealing of the apical foramen. For the assessment of the microleakage, Siqueira et al apparatus and method was used. All the specimens were divided into four groups based on the provisional restorative material used. All the groups were further divided into three subgroups based on the presence and absence of intracanal medicaments. Verissimo et al's criteria were used to check the turbidity at 1-, 2-, 3-, and 4-week interval respectively. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Chi-square test was used to measure the level of significance, and p < 0.05 was considered to be significant. In group I, all the subgroups' specimens showed significant difference at 1 week's time. Only the subgroup with no intracanal medicaments in Cavit-containing provisional restoration showed nonsignificant alterations. Statistically significant alterations were seen at 1, 2, and 3 weeks' interval in all the subgroups except for one with intracanal medicaments. All the temporary restorative materials were not able to prevent microleakage after 1 week's time, with worst bacterial resistance shown by Ketac Molar and ionomer restorative material. Future studies are advocated for better prognosis of root canal therapy.

  18. Microbial succession and stimulation following a test well injection simulating CO2 leakage into shallow Newark Basin aquifers

    NASA Astrophysics Data System (ADS)

    Dueker, M.; Clauson, K.; Yang, Q.; Umemoto, K.; Seltzer, A. M.; Zakharova, N. V.; Matter, J. M.; Stute, M.; Takahashi, T.; Goldberg, D.; O'Mullan, G. D.

    2012-12-01

    Despite growing appreciation for the importance of microbes in altering geochemical reactions in the subsurface, the microbial response to geological carbon sequestration injections and the role of microbes in altering metal mobilization following leakage scenarios in shallow aquifers remain poorly constrained. A Newark Basin test well was utilized in field experiments to investigate patterns of microbial succession following injection of CO2 saturated water into isolated aquifer intervals. Additionally, laboratory mesocosm experiments, including microbially-active and inactive (autoclave sterilized) treatments, were used to constrain the microbial role in mineral dissolution, trace metal release, and gas production (e.g. hydrogen and methane). Hydrogen production was detected in both sterilized and unsterilized laboratory mesocosm treatments, indicating abiotic hydrogen production may occur following CO2 leakage, and methane production was detected in unsterilized, microbially active mesocosms. In field experiments, a decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), the production of hydrogen gas, and increased bacterial cell concentrations. 16S ribosomal RNA clone libraries, from samples collected before and after the test well injection, were compared in an attempt to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injection, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia, Acidobacteria and other microbes associated with iron reducing and syntrophic metabolism. The concurrence of increased microbial cell concentration, and rapid microbial community succession, with increased concentrations of hydrogen gas suggests that abiotically produced hydrogen may serve as an ecologically-relevant energy source stimulating changes in aquifer microbial communities immediately following CO2 leakage.

  19. In vitro evaluation of the sealing ability of three newly developed root canal sealers: A bacterial microleakage study

    PubMed Central

    Sobhani, Ehsan; Samadi-Kafil, Hossein; Pirzadeh, Ahmad; Jafari, Sanaz

    2016-01-01

    Background The purpose of this study was to compare the sealing ability of MTA Fillapex, Apatite Root Canal Sealer and AH26 sealers. Material and Methods The present in vitro study was carried out on 142 extracted single-rooted human mature teeth. The teeth were randomly divided into three experimental groups (n=44) and two control groups (n=5). Three root canal sealers were MTA Fillapex, Apatite Root Canal Sealer and AH26. The teeth in the control groups were either filled with no sealer or made completely impermeable. The root canals were prepared and obturated with gutta-percha and one of the sealers. The teeth were sterilized with ethylene oxide gas prior to the bacterial leakage assessment using Enterococcus faecalis. Leakage was evaluated every 24 hours for 90 days. Data were analyzed with descriptive statistical methods and chi-squared test. If the data were significant, a proper post hoc test was used. Statistical significance was set at P<0.05. Results The positive control specimens exhibited total bacterial penetration whilst the negative control specimens showed no evidence of bacterial penetration. At the end of the study, the analysis of microleakage with chi-squared test showed no significant differences between the experimental groups (P<0.05). The results of chi-squared test analyzing the pair-wise differences between the groups considering the numerical values for leakage day indicated the lowest leakage with AH26 and the highest with Apatite root sealer. Conclusions According to the results of the present study, sealing ability of AH26 was significantly higher than that of MTA Fillapex and Apatite Root Canal Sealer. Key words:Mineral Trioxide aggregate, root canal obturation, dental seal. PMID:27957271

  20. Actively controlled shaft seals for aerospace applications

    NASA Technical Reports Server (NTRS)

    Salant, Richard F.

    1994-01-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100 C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changed suddenly.

  1. Understanding and Mitigating Tip Leakage and Endwall Losses in High Pressure Ratio Cores

    NASA Technical Reports Server (NTRS)

    Christophel, Jesse

    2015-01-01

    Reducing endwall and tip secondary flow losses will be a key enabler for the next generation of commercial and military air transport and will be an improvement on the state-of-the-art in turbine loss reduction strategies. The objective of this research is three-fold: 1) To improve understanding of endwall secondary flow and tip clearance losses 2) To develop novel technologies to mitigate these losses and test them in low-speed cascade and rig environments 3) To validate predictive tools To accomplish these objectives, Pratt & Whitney (P&W) has teamed with Pennsylvania State University (PSU) to experimentally test new features designed by P&W. P&W will create new rim-cavity features to reduce secondary flow loss and improve purge flow cooling effectiveness and new blade tip features to manage leakage flows and reduce tip leakage secondary flow loss. P&W is currently developing technologies in these two areas that expect to be assimilated in the N+2/N+3 generation of commercial engines.

  2. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    NASA Astrophysics Data System (ADS)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier feedback resistor independent of the leakage current level and polarity. The simulation results of the double, switchable, Krummenacher circuit-based feedback application in the CSA with a pulsed reset functionality are presented.

  3. Evaluation of oil-leakage of multi-layered resin-hose clamped with metal nipple and sleeve

    NASA Astrophysics Data System (ADS)

    Matsuoka, Kenta; Okubo, Kazuya; Fujii, Toru; Nakamura, Chihiro; Fujishita, Yushi; Kusu, Fuko; Matsushita, Masato; Yoshihara, Ryota

    2018-03-01

    The purpose of this study is to investigate the path of occurred oil-leakage of multi-layered resin-hose as one of multifunctional materials around the caulked joint with a metal nipple and sleeve when excessive cyclic internal pressure was applied onto the hose. Equivalent cyclic axial tensile force was substitutively applied to the hose, where same degree of normal stress was produced in longitudinal direction. Excessive 3 and 5 times of the standard load was applied to the hose. Cyclic loading was paused at every 1000 and 10000 cycles and then designed internal pressure was applied to the hose by a hand-operated pump with water in order to check whether the leakage was occurred around the joint and surface of the hose for safety evaluation. Cyclic fatigue life was defined as the number of loading cycles in which the leakage and the initial damage which was the passage of the ultrasonic wave was observed on the cyclic test. Test results showed the fatigue life at which leakage of water was observed was increased 20 times in case of K=3 compared to that in case of K=5. The cycles of initial damage detected by the ultrasonic wave were passed was increased 3.3 times in case of K=3 compared to that in case of K=5. The fluorescent agent penetrated from the core layer of resin hose to the reinforcement layer in which a half cross section along longitudinal direction in failed specimens was observed after the leak test. The original specimens had the gap between the resin-hose and the nipple and then the gap extended and connected during fatigue cyclic. In this study, it was observed that oil was leaked through narrow gap between the nipple and core layer of resin hose.

  4. Health, Safety, and Environmental Screening and Ranking Frameworkfor Geologic CO2 Storage Site Selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Curtis M.

    2006-03-15

    This report describes a screening and ranking framework(SRF) developed to evaluate potential geologic carbon dioxide (CO2)storage sites on the basis of health, safety, and environmental (HSE)risk arising from possible CO2 leakage. The approach is based on theassumption that HSE risk due to CO2 leakage is dependent on three basiccharacteristics of a geologic CO2 storage site: (1) the potential forprimary containment by the target formation, (2) the potential forsecondary containment if the primary formation leaks, and (3) thepotential for attenuation and dispersion of leaking CO2 if the primaryformation leaks and secondary containment fails. The framework isimplemented in a spreadsheet in whichmore » users enter numerical scoresrepresenting expert opinions or general information available frompublished materials along with estimates of uncertainty to evaluate thethree basic characteristics in order to screen and rank candidate sites.Application of the framework to the Rio Vista Gas Field, Ventura OilField, and Mammoth Mountain demonstrates the approach. Refinements andextensions are possible through the use of more detailed data or modelresults in place of property proxies. Revisions and extensions to improvethe approach are anticipated in the near future as it is used and testedby colleagues and collaborators.« less

  5. Treatment with sodium hyaluronate eye drops in a patient who had early-onset bleb leakage after trabeculectomy with mitomycin C

    PubMed Central

    Sagara, Hideto; Sekiryu, Tetsuju; Noji, Hiroki; Ogasawara, Masashi; Imaizumi, Kimihiro; Yago, Keiko

    2015-01-01

    We present the case of a 47-year-old man who had bilateral proliferative diabetic retinopathy and neovascular glaucoma. Schirmer I test revealed tear secretions of 5 mm and 3 mm in the right and left eyes, respectively. Tear breakup times in the right and left eyes were 7 and 8 seconds, respectively. The ocular surface staining in both eyes was scored as Grade 1 as per the Oxford scheme. Retinal photocoagulation was performed for correction of the proliferative diabetic retinopathy and rubeosis iridis, which resolved with treatment. However, the intraocular pressure in the left eye could not be adequately controlled. Therefore, trabeculectomy with mitomycin C using limbal-based conjunctival flap was performed. Three hours after the surgery, the patient developed a large and diffuse filtering bleb, but no leakage occurred from the conjunctival scar. However, on the first postoperative day, leakage was noted and the conjunctiva was at the leakage point. The leakage resolved transiently, but recurred the next day. Severe keratoconjunctival epithelial failure was detected, and the patient was administrated 0.1% sodium hyaluronate eye drops six times daily. The epithelial failure improved, and many microcysts were detected on the bleb surface where the epithelial failure improved. The leakage resolved 2 days after initiation of the sodium hyaluronate eye drops. The microcysts disappeared and the bleb surface became smooth 1 month later. PMID:26664245

  6. Treatment with sodium hyaluronate eye drops in a patient who had early-onset bleb leakage after trabeculectomy with mitomycin C.

    PubMed

    Sagara, Hideto; Sekiryu, Tetsuju; Noji, Hiroki; Ogasawara, Masashi; Imaizumi, Kimihiro; Yago, Keiko

    2015-01-01

    We present the case of a 47-year-old man who had bilateral proliferative diabetic retinopathy and neovascular glaucoma. Schirmer I test revealed tear secretions of 5 mm and 3 mm in the right and left eyes, respectively. Tear breakup times in the right and left eyes were 7 and 8 seconds, respectively. The ocular surface staining in both eyes was scored as Grade 1 as per the Oxford scheme. Retinal photocoagulation was performed for correction of the proliferative diabetic retinopathy and rubeosis iridis, which resolved with treatment. However, the intraocular pressure in the left eye could not be adequately controlled. Therefore, trabeculectomy with mitomycin C using limbal-based conjunctival flap was performed. Three hours after the surgery, the patient developed a large and diffuse filtering bleb, but no leakage occurred from the conjunctival scar. However, on the first postoperative day, leakage was noted and the conjunctiva was at the leakage point. The leakage resolved transiently, but recurred the next day. Severe keratoconjunctival epithelial failure was detected, and the patient was administrated 0.1% sodium hyaluronate eye drops six times daily. The epithelial failure improved, and many microcysts were detected on the bleb surface where the epithelial failure improved. The leakage resolved 2 days after initiation of the sodium hyaluronate eye drops. The microcysts disappeared and the bleb surface became smooth 1 month later.

  7. Impacts of simultaneous multislice acquisition on sensitivity and specificity in fMRI.

    PubMed

    Risk, Benjamin B; Kociuba, Mary C; Rowe, Daniel B

    2018-05-15

    Simultaneous multislice (SMS) imaging can be used to decrease the time between acquisition of fMRI volumes, which can increase sensitivity by facilitating the removal of higher-frequency artifacts and boosting effective sample size. The technique requires an additional processing step in which the slices are separated, or unaliased, to recover the whole brain volume. However, this may result in signal "leakage" between aliased locations, i.e., slice "leakage," and lead to spurious activation (decreased specificity). SMS can also lead to noise amplification, which can reduce the benefits of decreased repetition time. In this study, we evaluate the original slice-GRAPPA (no leak block) reconstruction algorithm and acceleration factor (AF = 8) used in the fMRI data in the young adult Human Connectome Project (HCP). We also evaluate split slice-GRAPPA (leak block), which can reduce slice leakage. We use simulations to disentangle higher test statistics into true positives (sensitivity) and false positives (decreased specificity). Slice leakage was greatly decreased by split slice-GRAPPA. Noise amplification was decreased by using moderate acceleration factors (AF = 4). We examined slice leakage in unprocessed fMRI motor task data from the HCP. When data were smoothed, we found evidence of slice leakage in some, but not all, subjects. We also found evidence of SMS noise amplification in unprocessed task and processed resting-state HCP data. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Comparison of holographic and numerical vibration modes on ductile cast iron containers at drop tests

    NASA Astrophysics Data System (ADS)

    Ettemeyer, Andreas; Schreiber, Dietmar; Voelzer, W.

    1996-08-01

    Ductile cast iron containers for transportation and deposition of radioactive waste have to be designed carefully in order to avoid unacceptable damages and leakages in case of an accident. Therefore various calculation and experimental methods are used during development and licensing of the containers. Besides others the container has to suffer severe impacts (e.g. falling from a height of several meters onto a concrete base). The level of strains must not exceed a value which would adversely affect the package in such a way that it would fail to meet the applicable requirements. In practice complex events such as drop tests are very difficult to calculate. Both the position of Maximum stress and the time of its occurrence are not easy to be predicted with the method of FEM. The uncertainty of the material modelling for plastic deformations by dynamic loading rates is the limiting factor. Therefore holography as an integral measuring technique in combination with strain gauge techniques were used to fit the FEM. By using the FEM calculations in the case of licensing, the FE and the material model have to be verified. The verification of the FE model has to be done by comparison of the local maxima measured by strain gauges and by comparison of the vibration modes. These vibration modes we take from holographic measurements. In this paper we explain container vibrations after impact analyzed with holographic measurements, FEM calculations and the comparison of the results. The comparison of the local maxima (strain gauges/FEM) is reported earlier.

  9. [Remote system of natural gas leakage based on multi-wavelength characteristics spectrum analysis].

    PubMed

    Li, Jing; Lu, Xu-Tao; Yang, Ze-Hui

    2014-05-01

    In order to be able to quickly, to a wide range of natural gas pipeline leakage monitoring, the remote detection system for concentration of methane gas was designed based on static Fourier transform interferometer. The system used infrared light, which the center wavelength was calibrated to absorption peaks of methane molecules, to irradiated tested area, and then got the interference fringes by converging collimation system and interference module. Finally, the system calculated the concentration-path-length product in tested area by multi-wavelength characteristics spectrum analysis algorithm, furthermore the inversion of the corresponding concentration of methane. By HITRAN spectrum database, Selected wavelength position of 1. 65 microm as the main characteristic absorption peaks, thereby using 1. 65 pm DFB laser as the light source. In order to improve the detection accuracy and stability without increasing the hardware configuration of the system, solved absorbance ratio by the auxiliary wave-length, and then get concentration-path-length product of measured gas by the method of the calculation proportion of multi-wavelength characteristics. The measurement error from external disturbance is caused by this innovative approach, and it is more similar to a differential measurement. It will eliminate errors in the process of solving the ratio of multi-wavelength characteristics, and can improve accuracy and stability of the system. The infrared absorption spectrum of methane is constant, the ratio of absorbance of any two wavelengths by methane is also constant. The error coefficients produced by the system is the same when it received the same external interference, so the measured noise of the system can be effectively reduced by the ratio method. Experimental tested standards methane gas tank with leaking rate constant. Using the tested data of PN1000 type portable methane detector as the standard data, and were compared to the tested data of the system, while tested distance of the system were 100, 200 and 500 m. Experimental results show that the methane concentration detected value was stable after a certain time leakage, the concentration-path-length product value of the system was stable. For detection distance of 100 m, the detection error of the concentration-path-length product was less than 1. 0%. With increasing distance from tested area, the detection error is increased correspondingly. When the distance was 500 m, the detection error was less than 4. 5%. In short, the detected error of the system is less than 5. 0% after the gas leakage stable, to meet the requirements of the field of natural gas leakage remote sensing.

  10. Thrust performance of a variable-geometry, divergent exhaust nozzle on a turbojet engine at altitude

    NASA Technical Reports Server (NTRS)

    Straight, D. M.; Collom, R. R.

    1983-01-01

    A variable geometry, low aspect ratio, nonaxisymmetric, two dimensional, convergent-divergent exhaust nozzle was tested at simulated altitude on a turbojet engine to obtain baseline axial, dry thrust performance over wide ranges of operating nozzle pressure ratios, throat areas, and internal expansion area ratios. The thrust data showed good agreement with theory and scale model test results after the data were corrected for seal leakage and coolant losses. Wall static pressure profile data were also obtained and compared with one dimensional theory and scale model data. The pressure data indicate greater three dimensional flow effects in the full scale tests than with models. The leakage and coolant penalties were substantial, and the method to determine them is included.

  11. Design of a leak detection device for marine airtight container

    NASA Astrophysics Data System (ADS)

    Li, Yuan; Zhu, Faxin; Lu, Jinshu; Li, Yule; Wu, Wenfeng; Zhang, Jianwei; Qin, Beichen

    2018-04-01

    The ship airtight container as the research object, according to the tightness of the traditional detection methods of sealed container from the shortcomings of the design of modern ship sealed container leak detection device based on the requirements of the use of AutoCAD to design a ship leakage detection device using airtight container, and introduces its working principle and main components. Finally, from the aspects of technology, structure, operation and economy, the feasibility analysis of the leak detection device for marine airtight container is designed, and it is concluded that the device has the advantages of simple operation, short detection time, easy maintenance and cost control, and has high feasibility.

  12. Leakage of fluid in different types of tracheal tubes.

    PubMed

    Winklmaier, U; Wüst, K; Schiller, S; Wallner, F

    2006-10-01

    The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.

  13. Hydrogeology of well-field areas near Tampa, Florida; Phase I, development and documentation of a two-dimensional finite-difference model for simulation of steady-state ground-water flow

    USGS Publications Warehouse

    Hutchinson, C.B.; Johnson, Dale M.; Gerhart, James M.

    1981-01-01

    A two-dimensional finite-difference model was developed for simulation of steady-state ground-water flow in the Floridan aquifer throughout a 932-square-mile area, which contains nine municipal well fields. The overlying surficial aquifer contains a constant-head water table and is coupled to the Floridan aquifer by a leakage term that represents flow through a confining layer separating the two aquifers. Under the steady-state condition, all storage terms are set to zero. Utilization of the head-controlled flux condition allows head and flow to vary at the model-grid boundaries. Procedures are described to calibrate the model, test its sensitivity to input-parameter errors, and verify its accuracy for predictive purposes. Also included are attachments that describe setting up and running the model. An example model-interrogation run shows anticipated drawdowns that should result from pumping at the newly constructed Cross Bar Ranch and Morris Bridge well fields. (USGS)

  14. Preliminary geological investigation of AIS data at Mary Kathleen, Queensland, Australia

    NASA Technical Reports Server (NTRS)

    Huntington, J. F.; Green, A. A.; Craig, M. D.; Cocks, T. D.

    1986-01-01

    The Airborne Imaging Spectrometer (AIS) was flown over granitic, volcanic, and calc-silicate terrain around the Mary Kathleen Uranium Mine in Queensland, in a test of its mineralocial mapping capabilities. An analysis strategy and restoration and enhancement techniques were developed to process the 128 band AIS data. A preliminary analysis of one of three AIS flight lines shows that the data contains considerable spectral variation but that it is also contaminated by second-order leakage of radiation from the near-infrared region. This makes the recognition of expected spectral absorption shapes very difficult. The effect appears worst in terrains containing considerable vegetation. Techniques that try to predict this supplementary radiation coupled with the log residual analytical technique show that expected mineral absorption spectra can be derived. The techniques suggest that with additional refinement correction procedures, the Australian AIS data may be revised. Application of the log residual analysis method has proved very successful on the cuprite, Nevada data set, and for highlighting the alunite, linite, and SiOH mineralogy.

  15. HEAT EXCHANGER

    DOEpatents

    Fox, T.H. III; Richey, T. Jr.; Winders, G.R.

    1962-10-23

    A heat exchanger is designed for use in the transfer of heat between a radioactive fiuid and a non-radioactive fiuid. The exchanger employs a removable section containing the non-hazardous fluid extending into the section designed to contain the radioactive fluid. The removable section is provided with a construction to cancel out thermal stresses. The stationary section is pressurized to prevent leakage of the radioactive fiuid and to maintain a safe, desirable level for this fiuid. (AEC)

  16. Relative performance comparison between baseline labyrinth and dual-brush compressor discharge seals in a T-700 engine test

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Griffin, Thomas A.; Kline, Teresa R.; Csavina, Kristine R.; Pancholi, Arvind; Sood, Devendra

    1995-01-01

    In separate series of YT-700 engine tests, direct comparisons were made between the forward-facing labyrinth and dual brush compressor discharge seals. Compressor speeds to 43 000 rpm, surface speeds to 160 m/s (530 ft/s), pressures to 1 MPa (145 psi), and temperatures to 680 K (765 F) characterized these tests. The wear estimate for 46 hr of engine operations was less than 0.025 mm (0.001 in.) of the Haynes 25 alloy bristles running against a chromium-carbide-coated rub runner. The pressure drops were higher for the dual-brush seal than for the forward-facing labyrinth seal and leakage was lower-with the labyrinth seal leakage being 2-1/2 times greater-implying better seal characteristics, better secondary airflow distribution, and better engine performance (3 percent at high pressure to 5 percent at lower pressure) for the brush seal. (However, as brush seals wear down (after 500 to 1000 hr of engine operation), their leakage rates will increase.) Modification of the secondary flow path requires that changes in cooling air and engine dynamics be accounted for.

  17. Experimental Research and Analysis of Rotordynamic Characteristics for a New Kind of Tilting-pad Gas Seal

    NASA Astrophysics Data System (ADS)

    Cao, Hao; Cao, Xiaoyu; Chen, Fei; Li, Ming; Zhang, Bolin; Wei, Jilong

    2017-12-01

    This paper presents a new kind of tilting-pad gas seal. This design is introduced to reduce the tangential seal force and to improve the stability of rotor system finally. A seal test rig is set up. The paper compares the leakage between tilting-pad seal and fixed pad seal. The result shows that the leakage ratio of the tilting-pad seal is close to the leakage ratio of the fixed pad seal. The work done by seal force on the cylinder system is calculated as an index of comparison between these two seals. Result shows that the work done by the fixed pad seal is greater than the work done by the tilting-pad seal. Moreover, system damping factor is used to compare the stabilities of these two seals. The impact tests on the cylinder system are done under different conditions. The system damping factors are calculated from the damped waves of system vibration. Test results show that the damping factor of the tilting pad seal is higher than that of the fixed pad seal in both the vertical and the horizontal directions.

  18. Compact, compression-free, displaceable, and resealable vacuum feedthrough with built-in strain relief for sensitive components such as optical fibers.

    PubMed

    Buchholz, B; Ebert, V

    2014-05-01

    For the direct fiber coupling of small optical measurement cells, we developed a new compact vacuum feedthrough for glass fibers and other similarly shaped objects that are compact and that offer the possibility of adjusting the fiber in longitudinal and in circular direction. The feedthrough assembly avoids compression or torsion on the fiber and thus protects, e.g., highly frangible fiber materials. In the following, we will present a brief simulation of the tightness requirements for low-pressure and low-concentration water vapor measurements and we will explain an integrated concept for a displaceable and self-adjustable, compression-free, compact, ultra-high vacuum, resealable feedthrough with good strain relief. The feedthrough has been successfully tested in a laboratory test facility and in several extractive airborne tunable diode laser absorption spectroscopy hygrometers. The leakage rate of the feedthrough presented here was tested via a helium leak searcher and was quantified further in an 8-week vacuum measurement campaign. The leakage rate is determined to be 0.41 ± 0.04 × 10(-9) hPa l/s, which--to our knowledge--is the first time a leakage rate for such a feedthrough has been quantified.

  19. Accelerating Universe from Gravitational Leakage into Extra Dimensions: Testing with Type Ia Supernovae

    NASA Astrophysics Data System (ADS)

    Zhu, Zong-Hong; Alcaniz, Jailson S.

    2005-02-01

    There is mounting observational evidence that the expansion of our universe is undergoing an acceleration. A dark energy component has usually been invoked as the most feasible mechanism for the acceleration. However, it is desirable to explore alternative possibilities motivated by particle physics before adopting such an untested entity. In this work, we focus our attention on an acceleration mechanism arising from gravitational leakage into extra dimensions. We test this scenario with high-z Type Ia supernovae compiled by Tonry and coworkers and recent measurements of the X-ray gas mass fractions in clusters of galaxies published by Allen and coworkers. A combination of the two databases gives, at a 99% confidence level, Ωm=0.29+0.04-0.02, Ωrc=0.21+/-0.08, and Ωk=-0.36+0.31-0.35, indicating a closed universe. We then constrain the model using the test of the turnaround redshift, zq=0, at which the universe switches from deceleration to acceleration. We show that, in order to explain that acceleration happened earlier than zq=0=0.6 within the framework of gravitational leakage into extra dimensions, a low matter density, Ωm<0.27, or a closed universe is necessary.

  20. 46 CFR 154.1810 - Cargo manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... leakage. (4) The use of the firefighting systems on the vessel. (5) The features of the cargo containment... detection systems. (x) Alarm or safety indication systems. (xi) Cargo jettisoning system. (xii) The system...) A description of gas detection systems and alarm or safety systems. (15) A description of the...

  1. 40 CFR 265.201 - Special requirements for generators of between 100 and 1,000 kg/mo that accumulate hazardous...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... confinement structures (e.g., dikes) at least weekly to detect erosion or obvious signs of leakage (e.g., wet... waste in tanks or tank systems that have full secondary containment and that either use leak detection...

  2. Photoelectrodialytic cell

    DOEpatents

    Murphy, George W.

    1983-01-01

    A multicompartment photoelectrodialytic demineralization cell is provided with a buffer compartment interposed between the product compartment and a compartment containing an electrolyte solution. Semipermeable membranes separate the buffer compartment from the product and electrolyte compartments. The buffer compartment is flushed to prevent leakage of the electrolyte compartment from entering the product compartment.

  3. Degradation of Leakage Currents in Solid Tantalum Capacitors Under Steady-State Bias Conditions

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2010-01-01

    Degradation of leakage currents in various types of solid tantalum capacitors under steady-state bias conditions was investigated at temperatures from 105 oC to 170 oC and voltages up to two times the rated voltage. Variations of leakage currents with time under highly accelerated life testing (HALT) and annealing, thermally stimulated depolarization currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. During HALT the currents increase gradually up to three orders of magnitude in some cases, and then stabilize with time. This degradation is reversible and annealing can restore the initial levels of leakage currents. The results are attributed to migration of positively charged oxygen vacancies in tantalum pentoxide films that diminish the Schottky barrier at the MnO2/Ta2O5 interface and increase electron injection. A simple model allows for estimation of concentration and mobility of oxygen vacancies based on the level of current degradation.

  4. Study of the dose rate effect of 180 nm nMOSFETs

    NASA Astrophysics Data System (ADS)

    He, Bao-Ping; Yao, Zhi-Bin; Sheng, Jiang-Kun; Wang, Zu-Jun; Huang, Shao-Yan; Liu, Min-Bo; Xiao, Zhi-Gang

    2015-01-01

    Radiation induced offstate leakage in the shallow trench isolation regions of SIMC 0.18 μm nMOSFETs is studied as a function of dose rate. A “true” dose rate effect (TDRE) is observed. Increased damage is observed at low dose rate (LDR) than at high dose rate (HDR) when annealing is taken into account. A new method of simulating radiation induced degradation in shallow trench isolation (STI) is presented. A comparison of radiation induced offstate leakage current in test nMOSFETs between total dose irradiation experiments and simulation results exhibits excellent agreement. The investigation results imply that the enhancement of the leakage current may be worse for the dose rate encountered in the environment of space.

  5. A study of cavity preparation by Er:YAG laser. Effects on the marginal leakage of composite resin restoration.

    PubMed

    Shigetani, Yoshimi; Tate, Yasuaki; Okamoto, Akira; Iwaku, Masaaki; Abu-Bakr, Neamat

    2002-09-01

    The purpose of this study was to evaluate marginal leakage of composite resin restoration from cavities prepared by Er:YAG laser. The observation of the dentin surface after the application of laser irradiation was performed by LSM, the cutting surface showed a rough surface similar to scales, and exposed dentinal tubules were observed without striations or a smeared layer formation that were observed when using a rotary cutting device. Leakage tests revealed no significant differences in the marginal seal for both enamel and dentin between cavities prepared by Er:YAG laser irradiation and when using an air-turbine. In this study, the usefulness of cavity preparation by Er:YAG laser irradiation in composite resin restoration was suggested.

  6. Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klocke, S.; Faakye, O.; Puttagunta, S.

    2014-10-01

    While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less

  7. Building America Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-11-01

    While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less

  8. Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klocke, S.; Faakye, O.; Puttagunta, S.

    2014-10-01

    ​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less

  9. Valve, explosive actuated, normally open, pyronetics model 1399

    NASA Technical Reports Server (NTRS)

    Avalos, E.

    1971-01-01

    Results of the tests to evaluate open valve, Model 1399 are reported for the the following tests: proof pressure leakage, actuation, disassembly, and burst pressure. It is concluded that the tests demonstrate the soundness of the structural integrity of the valve.

  10. Special Form Testing of Sealed Source Encapsulation for High-Alpha-Activity Actinide Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Oscar A

    In the United States all transportation of radioactive material is regulated by the U.S. Department of Transportation (DOT). Beginning in 2008 a new type of sealed-source encapsulation package was developed and tested by Oak Ridge National Laboratory (ORNL). These packages contain high-alpha-activity actinides and are regulated and transported in accordance with the requirements for DOT Class 7 hazardous material. The DOT provides specific regulations pertaining to special form encapsulation designs. The special form designation indicates that the encapsulated radioactive contents have a very low probability of dispersion even when subjected to significant structural events. The special form designs have beenmore » shown to simplify the delivery, transport, acceptance, and receipt processes. It is intended for these sealed-source encapsulations to be shipped to various facilities making it very advantageous for them to be certified as special form. To this end, DOT Certificates of Competent Authority (CoCAs) have been sought for the design suitable for containing high-alpha-activity actinide materials. This design consists of the high-alpha-activity material encapsulated within a triangular zirconia canister, referred to as a ZipCan, tile that is then enclosed by a spherical shell. The spherical shell design, with ZipCan tile inside, was tested for compliance with the special form regulations found in 49 CFR 173.469. The spherical enclosure was subjected to 9-m impact, 1 m percussion, and 10-minute thermal tests at the Packaging Evaluation Facility located at the National Transportation Research Center in Knoxville, TN USA and operated by ORNL. Before and after each test, the test units were subjected to a helium leak check and a bubble test. The ZipCan tiles and core were also subjected to the tests required for ISO 2919:2012(E), including a Class IV impact test and heat test and subsequently subjected to helium leakage rate tests [49 CFR 173.469(a)(4)(i)]. The impact-tile test unit contained a nonradioactive surrogate; however, the thermal test unit contained a radioactive source. This paper describes the regulatory special form tests and presents detailed impact and leak test results that demonstrate that the sealed source encapsulation designs satisfy the regulatory tests.« less

  11. Power Electronic Transformer based Three-Phase PWM AC Drives

    NASA Astrophysics Data System (ADS)

    Basu, Kaushik

    A Transformer is used to provide galvanic isolation and to connect systems at different voltage levels. It is one of the largest and most expensive component in most of the high voltage and high power systems. Its size is inversely proportional to the operating frequency. The central idea behind a power electronic transformer (PET) also known as solid state transformer is to reduce the size of the transformer by increasing the frequency. Power electronic converters are used to change the frequency of operation. Steady reduction in the cost of the semiconductor switches and the advent of advanced magnetic materials with very low loss density and high saturation flux density implies economic viability and feasibility of a design with high power density. Application of PET is in generation of power from renewable energy sources, especially wind and solar. Other important application include grid tied inverters, UPS e.t.c. In this thesis non-resonant, single stage, bi-directional PET is considered. The main objective of this converter is to generate adjustable speed and magnitude pulse width modulated (PWM) ac waveforms from an ac or dc grid with a high frequency ac link. The windings of a high frequency transformer contains leakage inductance. Any switching transition of the power electronic converter connecting the inductive load and the transformer requires commutation of leakage energy. Commutation by passive means results in power loss, decrease in the frequency of operation, distortion in the output voltage waveform, reduction in reliability and power density. In this work a source based partially loss-less commutation of leakage energy has been proposed. This technique also results in partial soft-switching. A series of converters with novel PWM strategies have been proposed to minimize the frequency of leakage inductance commutation. These PETs achieve most of the important features of modern PWM ac drives including 1) Input power factor correction, 2) Common-mode voltage suppression at the load end, 3) High quality output voltage waveform (comparable to conventional space vector PWM modulated two level inverter) and 4) Minimization of output voltage loss, common-mode voltage switching and distortion of the load current waveform due to leakage inductance commutation. All of the proposed topologies along with the proposed control schemes have been analyzed and simulated in MATLABSimulink. A hardware prototype has been fabricated and tested. The simulation and experimental results verify the operation and advantages of the proposed topologies and their control.

  12. Influence of Functionalization of Nanocontainers on Self-Healing Anticorrosive Coatings.

    PubMed

    Zheng, Zhaoliang; Schenderlein, Matthias; Huang, Xing; Brownbill, Nick J; Blanc, Frédéric; Shchukin, Dmitry

    2015-10-21

    Feedback coating based on pH-induced release of inhibitor from organosilyl-functionalized containers is considered as a compelling candidate to achieve smart self-healing corrosion protection. Four key factors that determine the overall coating performance include (1) the uptake and release capacity of containers, (2) prevention of the premature leakage, (3) compatibility of containers in coating matrix, and (4) cost and procedure simplicity consideration. The critical influence introduced by organosilyl-functionalization of containers is systematically demonstrated by investigating MCM-41 silica nanoparticles modified with ethylenediamine (en), en-4-oxobutanoic acid salt (en-COO(-)), and en-triacetate (en-(COO(-))3) with higher and lower organic contents. The properties of the modified silica nanoparticles as containers were mainly characterized by solid-state (13)C nuclear magnetic resonance, scanning and transmission electron microscopy, N2 sorption, thermogravimetric analysis, small-angle X-ray scattering, dynamic light scattering, and UV-vis spectroscopy. Finally, the self-healing ability and anticorrosive performances of hybrid coatings were examined through scanning vibrating electrode technique (SVET) and electrochemical impedance spectroscopy (EIS). We found that en-(COO(-))3-type functionalization with content of only 0.23 mmol/g performed the best as a candidate for establishing pH-induced release system because the resulting capped and loaded (C-L) functionalized silica nanocontainers (FSNs) exhibit high loading (26 wt %) and release (80%) capacities for inhibitor, prevention of premature leakage (less than 2%), good dispersibility in coating matrix, and cost effectiveness.

  13. Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures.

    PubMed

    Anselmetti, Giovanni Carlo; Zoarski, Gregg; Manca, Antonio; Masala, Salvatore; Eminefendic, Haris; Russo, Filippo; Regge, Daniele

    2008-01-01

    The aim of this study was to assess the feasibility of and venous leakage reduction in percutaneous vertebroplasty (PV) using a new high-viscosity bone cement (PMMA). PV has been used effectively for pain relief in osteoporotic and malignant vertebral fractures. Cement extrusion is a common problem and can lead to complications. Sixty patients (52 female; mean age, 72.2 +/- 7.2) suffering from osteoporosis (46), malignancy (12), and angiomas (2), divided into two groups (A and B), underwent PV on 190 vertebrae (86 dorsal, 104 lumbar). In Group A, PV with high-viscosity PMMA (Confidence, Disc-O-Tech, Israel) was used. This PMMA was injected by a proprietary delivery system, a hydraulic saline-filled screw injector. In Group B, a standard low-viscosity PMMA was used. Postprocedural CT was carried out to detect PMMA leakages and complications. Fisher's exact test and Wilcoxon rank test were used to assess significant differences (p < 0.05) in leakages and to evaluate the clinical outcome. PV was feasible, achieving good clinical outcome (p < 0.0001) without major complications. In Group A, postprocedural CT showed an asymptomatic leak in the venous structures of 8 of 98 (8.2%) treated vertebrae; a discoidal leak occurred in 6 of 98 (6.1%). In Group B, a venous leak was seen in 38 of 92 (41.3%) and a discoidal leak in 12 of 92 (13.0%). Reduction of venous leak obtained by high-viscosity PMMA was highly significant (p < 0.0001), whereas this result was not significant (p = 0.14) related to the disc. The high-viscosity PMMA system is safe and effective for clinical use, allowing a significant reduction of extravasation rate and, thus, leakage-related complications.

  14. Risk factors influencing the early outcome results after laparoscopic repair of perforated duodenal ulcer and their predictive value.

    PubMed

    Lunevicius, Raimundas; Morkevicius, Matas

    2005-09-01

    Clear patient selection criteria and indications for laparoscopic repair of perforated duodenal ulcers are necessary. The aims of our study are to report the early outcome results after operation and to define the predictive values of risk factors influencing conversion rate and genesis of suture leakage. Sixty nonrandomly selected patients operated on laparoscopically in a tertiary care academic center between October 1996 and May 2004 for perforated duodenal ulcers were retrospectively analyzed. The primary outcome measures included the duration of symptoms, shock, underlying medical illness, ulcer size, age, Boey score, and the collective predictive value of these variables for conversion and suture leakage rates. Laparoscopic repair was completed in 46 patients (76.7%). Fourteen patients (23.3%) underwent conversion to open repair. Eight patients (13.3%) had postoperative complications. Suture leakage was confirmed in four patients (6.7%). Hospital stay was 7.8+/-5.3 days. There was no mortality. Patients with an ulcer perforation size of >8 mm had a significantly increased risk for conversion to open repair (p<0.05): positive predictive value (PPV) 75%, sensitivity 27%, specificity 98%, and negative predictive value (NPV) 85%. The significance of ulcer perforation size was confirmed by a stepwise logistic regression test (p=0.0201). All patients who developed suture leakage had acute symptoms for >9 h preoperatively (p<0.001): PPV 31%, specificity 84%, sensitivity 100%, and NPV 100%. Conversions happened with surgeons whose previous experience involved 1.8+/-2.3 cases compared to 3.9+/-2.9 cases in successful laparoscopic repair (p=0.039, t test). Ulcer perforation size of >8 mm is a significant risk factor influencing the conversion rate. An increase in the suture leakage rate is predicted by delayed presentation of >9 h.

  15. Depression of the Thoracolumbar Posterior Vertebral Body on the Estimation of Cement Leakage in Vertebroplasty and Kyphoplasty Operations

    PubMed Central

    Chen, Hao; Jia, Pu; Bao, Li; Feng, Fei; Yang, He; Li, Jin-Jun; Tang, Hai

    2015-01-01

    Background: The cross-section of thoracolumbar vertebral body is kidney-shaped with depressed posterior boundary. The anterior wall of the vertebral canal is separated from the posterior wall of the vertebral body on the lateral X-ray image. This study was designed to determine the sagittal distance between the anterior border of the vertebral canal and the posterior border of the vertebral body (DBCV) and to analyze the potential role of DBCV in the estimation of cement leakage during percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). Methods: We retrospectively recruited 233 patients who had osteoporotic vertebral compression fractures and were treated with PVP or PKP. Computed tomography images of T11–L2 normal vertebrae were measured to obtain DBCV. The distance from cement to the posterior wall of the vertebral body (DCPW) of thoracolumbar vertebrae was measured from C-arm images. The selected vertebrae were divided into two groups according to DCPW, with the fracture levels, fracture grades and leakage rates of the two groups compared. A relative operating characteristic (ROC) curve was applied to determine whether the DCPW difference can be used to estimate the degree of cement leakage. The data were processed by statistical software SPSS version 21.0 using independent sample t-test and Chi-square tests. Results: The maximum DBCV was 6.40 mm and the average DBCV was 3.74 ± 0.95 mm. DBCV appeared to be longer in males than in females, but the difference was not statistically significant. The average DCPW of type-B leakage vertebrae (2.59 ± 1.20 mm) was shorter than that of other vertebrae (7.83 ± 2.38 mm, P < 0.001). The leakage rate of group DCPW ≤6.40 mm was lower than that of group DCPW >6.40 mm for type-C and type-S, but much higher for type-B. ROC curve revealed that DCPW only has a predictive value for type-B leakage (area under the curve: 0.98, 95% confidence interval: 0.95–0.99, P < 0.001), and when the cut-off value was 4.05 mm, the diagnostic sensitivity and the specificity were 94.87% and 93.02%, respectively. Conclusions: Depression of the thoracolumbar posterior vertebral body may be informative for the estimation of cement location on C-arm images. To reduce type-B leakage, DCPW should be made longer than DBCV on C-arm images for safety during PVP or PKP. PMID:26612289

  16. Depression of the Thoracolumbar Posterior Vertebral Body on the Estimation of Cement Leakage in Vertebroplasty and Kyphoplasty Operations.

    PubMed

    Chen, Hao; Jia, Pu; Bao, Li; Feng, Fei; Yang, He; Li, Jin-Jun; Tang, Hai

    2015-12-05

    The cross-section of thoracolumbar vertebral body is kidney-shaped with depressed posterior boundary. The anterior wall of the vertebral canal is separated from the posterior wall of the vertebral body on the lateral X-ray image. This study was designed to determine the sagittal distance between the anterior border of the vertebral canal and the posterior border of the vertebral body (DBCV) and to analyze the potential role of DBCV in the estimation of cement leakage during percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). We retrospectively recruited 233 patients who had osteoporotic vertebral compression fractures and were treated with PVP or PKP. Computed tomography images of T11-L2 normal vertebrae were measured to obtain DBCV. The distance from cement to the posterior wall of the vertebral body (DCPW) of thoracolumbar vertebrae was measured from C-arm images. The selected vertebrae were divided into two groups according to DCPW, with the fracture levels, fracture grades and leakage rates of the two groups compared. A relative operating characteristic (ROC) curve was applied to determine whether the DCPW difference can be used to estimate the degree of cement leakage. The data were processed by statistical software SPSS version 21.0 using independent sample t-test and Chi-square tests. The maximum DBCV was 6.40 mm and the average DBCV was 3.74 ± 0.95 mm. DBCV appeared to be longer in males than in females, but the difference was not statistically significant. The average DCPW of type-B leakage vertebrae (2.59 ± 1.20 mm) was shorter than that of other vertebrae (7.83 ± 2.38 mm, P < 0.001). The leakage rate of group DCPW ≤6.40 mm was lower than that of group DCPW >6.40 mm for type-C and type-S, but much higher for type-B. ROC curve revealed that DCPW only has a predictive value for type-B leakage (area under the curve: 0.98, 95% confidence interval: 0.95-0.99, P < 0.001), and when the cut-off value was 4.05 mm, the diagnostic sensitivity and the specificity were 94.87% and 93.02%, respectively. Depression of the thoracolumbar posterior vertebral body may be informative for the estimation of cement location on C-arm images. To reduce type-B leakage, DCPW should be made longer than DBCV on C-arm images for safety during PVP or PKP.

  17. Design of a Two Dimensional Planer Pressurized Air Labyrinth Seal Test Rig

    DTIC Science & Technology

    1993-12-01

    identity by block number) Dump Diffuser, Flow Modification, Laser Doppler Velocimeter, Labyrinth Seal , Leakage Prediction, Press --ized air 19 Abstract...reducing this high to low pressure leakage . Figure 1.1 is a two dimensional representation of a 3 dimensional annular labyrinth seal . The object of this... Labyrinth Seal literature, Sneck [2] credits C.A. Parsons with development of the labyrinth seal in concert with Parson’s [31 development of the steam

  18. Advanced Electrical Test Techniques for LSI Microcircuits.

    DTIC Science & Technology

    1982-03-01

    high resistance polysilicon load resistors stacked in the "Z" direction for higher packing density. Featuring resistors typically in the gigaohm range...are made up of "N" diffusions, metal and/or polysilicon lines, and transistors, they are subject to leakage defects. If the leakage of the nonconducting...reference 7) show- ing a poor connection from the FF lead resistor ( Polysilicon ) to the Vcc or the transistor. The FF layout of Figure 1B shows that

  19. Imaging Polarimetry in Central Serous Chorioretinopathy

    PubMed Central

    MIURA, MASAHIRO; ELSNER, ANN E.; WEBER, ANKE; CHENEY, MICHAEL C.; OSAKO, MASAHIRO; USUI, MASAHIKO; IWASAKI, TAKUYA

    2006-01-01

    PURPOSE To evaluate a noninvasive technique to detect the leakage point of central serous chorioretinopathy (CSR), using a polarimetry method. DESIGN Prospective cohort study. METHODS SETTING Institutional practice. PATIENTS We examined 30 eyes of 30 patients with CSR. MAIN OUTCOME MEASURES Polarimetry images were recorded using the GDx-N (Laser Diagnostic Technologies). We computed four images that differed in their polarization content: a depolarized light image, an average reflectance image, a parallel polarized light image, and a birefringence image. Each polarimetry image was compared with abnormalities seen on fluorescein angiography. RESULTS In all eyes, leakage area could be clearly visualized as a bright area in the depolarized light images. Michelson contrasts for the leakage areas were 0.58 ± 0.28 in the depolarized light images, 0.17 ± 0.11 in the average reflectance images, 0.09 ± 0.09 in the parallel polarized light images, and 0.11 ± 0.21 in the birefringence images from the same raw data. Michelson contrasts in depolarized light images were significantly higher than for the other three images (P < .0001, for all tests, paired t test). The fluid accumulated in the retina was well-visualized in the average and parallel polarized light images. CONCLUSIONS Polarization-sensitive imaging could readily localize the leakage point and area of fluid in CSR. This may assist with the rapid, noninvasive assessment of CSR. PMID:16376644

  20. Photoelectrodialytic cell

    DOEpatents

    Murphy, G.W.

    1983-09-13

    A multicompartment photoelectrodialytic demineralization cell is provided with a buffer compartment interposed between the product compartment and a compartment containing an electrolyte solution. Semipermeable membranes separate the buffer compartment from the product and electrolyte compartments. The buffer compartment is flushed to prevent leakage of the electrolyte compartment from entering the product compartment. 3 figs.

  1. 40 CFR 264.1101 - Design and operating standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... hazardous waste (e.g., upon detection of leakage from the primary barrier) the owner or operator must: (A... constituents into the barrier, and a leak detection system that is capable of detecting failure of the primary... requirements of the leak detection component of the secondary containment system are satisfied by installation...

  2. 40 CFR 721.1150 - Substituted polyglycidyl ben-zena-mine.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... They have also caused allergic reactions in humans. —Prevent all contact with skin, eyes, and clothing...-impervious clothing before re-use. —Wash thoroughly after handling and before eating, drinking, or smoking. STORAGE INSTRUCTIONS: —Keep closure tight and upright to prevent leakage. —Keep container closed during...

  3. Photointercalating Semiconductor/Solid Electrolyte Junctions for Storage and Chemical Detection. Phase 2.

    DTIC Science & Technology

    1988-05-31

    character- isti, s of single crystal n-HfS 2 in liquid non-aqueous electrolyte (acetonitrile containing O.1M tetrabutylammonium hexafluorophosphate ...INC There are several incentives for the direct detection of SO2 under ambient conditions. These include potential leakage from pressurized lithium /SO

  4. 49 CFR 178.345-5 - Manhole assemblies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Manhole assemblies. 178.345-5 Section 178.345-5... Containers for Motor Vehicle Transportation § 178.345-5 Manhole assemblies. (a) Each cargo tank with capacity... manhole, fill opening and washout assembly must be structurally capable of withstanding, without leakage...

  5. 49 CFR 178.345-5 - Manhole assemblies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Manhole assemblies. 178.345-5 Section 178.345-5... Containers for Motor Vehicle Transportation § 178.345-5 Manhole assemblies. (a) Each cargo tank with capacity... manhole, fill opening and washout assembly must be structurally capable of withstanding, without leakage...

  6. 49 CFR 178.345-5 - Manhole assemblies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Manhole assemblies. 178.345-5 Section 178.345-5... Containers for Motor Vehicle Transportation § 178.345-5 Manhole assemblies. (a) Each cargo tank with capacity... manhole, fill opening and washout assembly must be structurally capable of withstanding, without leakage...

  7. 49 CFR 178.345-5 - Manhole assemblies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Manhole assemblies. 178.345-5 Section 178.345-5... Containers for Motor Vehicle Transportation § 178.345-5 Manhole assemblies. (a) Each cargo tank with capacity... manhole, fill opening and washout assembly must be structurally capable of withstanding, without leakage...

  8. 21 CFR 114.80 - Processes and controls.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... scheduled process and maintained in all finished foods. Manufacturing shall be in accordance with the... occur often enough to ensure that the container suitably protects the food from leakage or contamination... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Processes and controls. 114.80 Section 114.80 Food...

  9. Containment wells to form hydraulic barriers along site boundaries.

    PubMed

    Vo, D; Ramamurthy, A S; Qu, J; Zhao, X P

    2008-12-15

    In the field, aquifer remediation methods include pump and treat procedures based on hydraulic control systems. They are used to reduce the level of residual contamination present in the soil and soil pores of aquifers. Often, physical barriers are erected along the boundaries of the target (aquifer) site to reduce the leakage of the released soil contaminant to the surrounding regions. Physical barriers are expensive to build and dismantle. Alternatively, based on simple hydraulic principles, containment wells or image wells injecting clear water can be designed and built to provide hydraulic barriers along the contaminated site boundaries. For brevity, only one pattern of containment well system that is very effective is presented in detail. The study briefly reports about the method of erecting a hydraulic barrier around a contaminated region based on the simple hydraulic principle of images. During the clean-up period, hydraulic barriers can considerably reduce the leakage of the released contaminant from the target site to surrounding pristine regions. Containment wells facilitate the formation of hydraulic barriers. Hence, they control the movement of contaminants away from the site that is being remedied. However, these wells come into play, only when the pumping operation for cleaning up the site is active. After operation, they can be filled with soil to permit the natural ground water movement. They can also be used as monitoring wells.

  10. Exhaust-System Leak Test : Quantitative Procedure

    DOT National Transportation Integrated Search

    1974-01-01

    A quantitative, periodic motor vehicle safety-inspection test for determining the leakage rate of engine exhaust from an automotive exhaust system was investigated. Two technical approaches were evaluated, and the better one was selected for developm...

  11. An Evaluation of a High Pressure Regulator for NASA's Robotic Lunar Lander Spacecraft

    NASA Technical Reports Server (NTRS)

    Burnside, Christopher G.; Trinh, Huu P.; Pedersen, Kevin W.

    2013-01-01

    The Robotic Lunar Lander (RLL) development project office at NASA Marshall Space Flight Center is currently studying several lunar surface science mission concepts. The focus is on spacecraft carrying multiple science instruments and power systems that will allow extended operations on the lunar surface or other air-less bodies in the solar system. Initial trade studies of launch vehicle options indicate the spacecraft will be significantly mass and volume constrained. Because of the investment by the DOD in low mass, highly volume efficient components, NASA has investigated the potential integration of some of these technologies in space science applications. A 10,000 psig helium pressure regulator test activity has been conducted as part of the overall risk reduction testing for the RLL spacecraft. The regulator was subjected to typical NASA acceptance testing to assess the regulator response to the expected RLL mission requirements. The test results show the regulator can supply helium at a stable outlet pressure of 740 psig within a +/- 5% tolerance band and maintain a lock-up pressure less than the +5% above nominal outlet pressure for all tests conducted. Numerous leak tests demonstrated leakage less than 10-3 standard cubic centimeters per second (SCCS) for the internal seat leakage at lock-up and less than 10-5 SCCS for external leakage through the regulator body. The successful test has shown the potential for 10,000 psig helium systems in NASA spacecraft and has reduced risk associated with hardware availability and hardware ability to meet RLL mission requirements.

  12. Field Tests of Real-time In-situ Dissolved CO2 Monitoring for CO2 Leakage Detection in Groundwater

    NASA Astrophysics Data System (ADS)

    Yang, C.; Zou, Y.; Delgado, J.; Guzman, N.; Pinedo, J.

    2016-12-01

    Groundwater monitoring for detecting CO2 leakage relies on groundwater sampling from water wells drilled into aquifers. Usually groundwater samples are required be collected periodically in field and analyzed in the laboratory. Obviously groundwater sampling is labor and cost-intensive for long-term monitoring of large areas. Potential damage and contamination of water samples during the sampling process can degrade accuracy, and intermittent monitoring may miss changes in the geochemical parameters of groundwater, and therefore signs of CO2 leakage. Real-time in-situ monitoring of geochemical parameters with chemical sensors may play an important role for CO2 leakage detection in groundwater at a geological carbon sequestration site. This study presents field demonstration of a real-time in situ monitoring system capable of covering large areas for detection of low levels of dissolved CO2 in groundwater and reliably differentiating natural variations of dissolved CO2 concentration from small changes resulting from leakage. The sand-alone system includes fully distributed fiber optic sensors for carbon dioxide detection with a unique sensor technology developed by Intelligent Optical Systems. The systems were deployed to the two research sites: the Brackenridge Field Laboratory where the aquifer is shallow at depths of 10-20 ft below surface and the Devine site where the aquifer is much deeper at depths of 140 to 150 ft. Groundwater samples were periodically collected from the water wells which were installed with the chemical sensors and further compared to the measurements of the chemical sensors. Our study shows that geochemical monitoring of dissolved CO2 with fiber optic sensors could provide reliable CO2 leakage signal detection in groundwater as long as CO2 leakage signals are stronger than background noises at the monitoring locations.

  13. Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia.

    PubMed

    Kida, Yoshiko; Ohshimo, Shinichiro; Kyo, Michihito; Tanabe, Yuko; Suzuki, Kei; Hosokawa, Koji; Shime, Nobuaki

    2018-06-02

    Extracorporeal membrane oxygenation (ECMO) is an emerging tool for supporting cardiopulmonary function in patients with cardiorespiratory failure or arrest. The oxygenator of the ECMO circuit requires effective oxygenation and removal of carbon dioxide from the blood. Major problems that can occur with the oxygenator include plasma leakage, one of the late-onset serious complications necessitating device replacement. However, the rapid onset of plasma leakage is rare. We present a 1-year-old boy with acute respiratory failure due to Pneumocystis and Aspergillus pneumonia. He presented with tachypnea, tachycardia, and hypoxemia despite the ventilatory support, and was therefore placed on venoarterial ECMO with a drainage catheter from the right internal jugular vein (12 Fr) and a return catheter to the right internal carotid artery (10 Fr). Extracorporeal circulation was initiated at a blood flow of 1 L/min (145 mL/kg/min) and a sweep gas flow of 1 L/min with FiO 2 of 0.7. Although he was successfully weaned from the venoarterial ECMO on day 15 with an improvement of cardiopulmonary function, he was later placed on venoarterial ECMO again because of the progression of pulmonary hypertension. Laboratory tests showed increased concentrations of hepatic enzymes and hyperbilirubinemia (total bilirubin 31.6 mg/dL). Six hours after starting ECMO circulation, plasma leakage from the oxygenator occurred. Although we replaced the oxygenator with a new one, the replacement showed plasma leakage after 6 h. Disassembly of the oxygenator revealed congestion from bilirubin in the membrane fibers. We described a case of repeated, rapid-onset plasma leakage after implementation of ECMO. Hyperbilirubinemia was likely associated with the plasma leakage of this patient.

  14. Effects of sub-seabed CO2 leakage: Short- and medium-term responses of benthic macrofaunal assemblages.

    PubMed

    Amaro, T; Bertocci, I; Queiros, A M; Rastelli, E; Borgersen, G; Brkljacic, M; Nunes, J; Sorensen, K; Danovaro, R; Widdicombe, S

    2018-03-01

    The continued rise in atmospheric carbon dioxide (CO 2 ) levels is driving climate change and temperature shifts at a global scale. CO 2 Capture and Storage (CCS) technologies have been suggested as a feasible option for reducing CO 2 emissions and mitigating their effects. However, before CCS can be employed at an industrial scale, any environmental risks associated with this activity should be identified and quantified. Significant leakage of CO 2 from CCS reservoirs and pipelines is considered to be unlikely, however direct and/or indirect effects of CO 2 leakage on marine life and ecosystem functioning must be assessed, with particular consideration given to spatial (e.g. distance from the source) and temporal (e.g. duration) scales at which leakage impacts could occur. In the current mesocosm experiment we tested the potential effects of CO 2 leakage on macrobenthic assemblages by exposing infaunal sediment communities to different levels of CO 2 concentration (400, 1000, 2000, 10,000 and 20,000 ppm CO 2 ), simulating a gradient of distance from a hypothetic leakage, over short-term (a few weeks) and medium-term (several months). A significant impact on community structure, abundance and species richness of macrofauna was observed in the short-term exposure. Individual taxa showed idiosyncratic responses to acidification. We conclude that the main impact of CO 2 leakage on macrofaunal assemblages occurs almost exclusively at the higher CO 2 concentration and over short time periods, tending to fade and disappear at increasing distance and exposure time. Although under the cautious perspective required by the possible context-dependency of the present findings, this study contributes to the cost-benefit analysis (environmental risk versus the achievement of the intended objectives) of CCS strategies. Copyright © 2018. Published by Elsevier Ltd.

  15. The ``Leakage Current Sentinel'': A novel plug-in socket device for online biomedical equipment electrical safety surveillance

    NASA Astrophysics Data System (ADS)

    Cappa, Paolo; Marinozzi, Franco; Sciuto, Salvatore Andrea

    2000-07-01

    The Leakage Current Sentinel (LCS) has been designed and implemented for the detection of hazardous situations caused by dangerous earth leakage current values in intensive care units and operating theaters. The device, designed and manufactured with full compliance of the high risk environment requirements, is able to monitor online the earth leakage current and detect ground wire faults. Operation utilizes a microammeter with an overall sensitivity of 2.5×104 V/A. In order to assure the reliability of the device in providing alarm signals, the simultaneous presence of absorbed power current is monitored by means of another ammeter with decreased sensitivity (3.0 V/A). The measured root mean square current values are compared with reference values in order to send signals to NAND and OR complementary metal-oxide-semiconductor gates to enable audible and visible alarms according to the possible hazardous cases examined in the article. The final LCS packaging was shaped as a wall socket adapter for common electromedical device power cord plugs, with particular attention to minimizing its dimensions and to provide analog voltage outputs for both measured leakage and power currents, in order to allow automatic data acquisition and computerized hazardous situation management. Finally, a personal computer based automatic measuring system has been configured to simultaneously monitor several LCSs installed in the same intensive care unit room and, as a consequence, to distinguish different hazardous scenarios and provide an adequate alert to the clinical personnel whose final decision is still required. The test results confirm the effectiveness and reliability of the LCS in giving an alert in case of leakage current anomalous values, either in case of a ground fault or in case of a dangerous leakage current.

  16. Southern ocean winds during past (and future) warm periods and their affect on Agulhas Leakage and the Atlantic Merdional Overturning Circulation

    NASA Astrophysics Data System (ADS)

    Patel, N. P.; Deconto, R. M.; Condron, A.

    2013-12-01

    The leakage of Agulhas Current water into the South Atlantic is now thought to be a major player in global climate change. The volume of Agulhas Leakage is linked to the strength and position of southern westerlies. Past changes in the westerly winds over the southern ocean have been noted on glacial-interglacial timescales, in response to both Northern Hemispheric conditions and more proximal changes in Antarctic ice volume. Over recent decades, a southward shift in the southern ocean westerlies has been observed and is expected to continue with projected climate warming. The resulting increase in Agulhas Leakage is thought to allow more warm, salty water from the Indian Ocean into the Atlantic, with the potential to impact the Atlantic Meridional Overturning circulation (AMOC). Some climate models have predicted global warming will result in a slowdown and weakening of the AMOC. A strengthening of the Agulhas Leakage therefore has the potential to counteract that slowdown. Much of the Agulhas leakage is carried in small eddies rotating off the main flow south of Cape Horn. High ocean model resolution (< 1/2°) is therefore required to simulate their response to the overlying wind field. However the majority of previous model studies have been too coarse in resolution to quantify the link between the Agulhas Leakage the AMOC. Here we run a series of global high-resolution ocean model (1/6°) experiments using the MITgcm to test the effect of a shift in the southern hemisphere westerlies on the Agulhas Leakage. A prescribed perturbation of the winds near South Africa shows a significant increase in Agulhas eddies into the Atlantic. Following this, we have conducted longer simulations with the winds over the Southern Ocean perturbed to reflect both past and possible future shifts in the wind field to quantify changes in North Atlantic Deep Water formation and the overall response of the AMOC to this perturbation.

  17. Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery.

    PubMed

    Masket, Samuel; Hovanesian, John A; Levenson, Jeffrey; Tyson, Farrell; Flynn, William; Endl, Michael; Majmudar, Parag A; Modi, Satish; Chu, Ralph; Raizman, Michael B; Lane, Stephen S; Kim, Terry

    2014-12-01

    To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. Twenty-four ophthalmic clinical practices in the United States. Prospective randomized parallel-arm controlled multicenter subject-masked study. Healthy patients having uneventful clear corneal incision (CCI) cataract surgery were eligible for the study. Spontaneous and provoked fluid egress from wounds was evaluated at the time of surgery using a calibrated force gauge. Eyes with leakage were randomized to receive a hydrogel sealant (Resure) or a nylon suture at the main incision site. Incision leakage was reevaluated 1, 3, 7, and 28 days postoperatively. Of 500 eyes, 488 had leakage at the time of cataract surgery. The leak was spontaneous in 244 cases (48.8%), and 488 (97.6%) of all incisions leaked with 1.0 ounce or less of applied force. After randomization, 12 (4.1%) of 295 eyes in the sealant group and 60 (34.1%) of 176 eyes in the suture group had wound leakage with provocation (P<.0001). The overall incidence of adverse ocular events was statistically significantly lower in the sealant group than in the suture group (P<.05). In this study, 97.6% of CCIs leaked after cataract surgery. The hydrogel sealant was safe and effective and better than a suture for the intraoperative management of CCIs with leakage as seen on Seidel testing and for the prevention of postoperative fluid egress. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Hanford Double-Shell Tank AY-102 Radioactive Waste Leak Investigation Update - 15302

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washenfelder, D. J.; Johnson, J. M.

    2014-12-22

    Tank AY-102 was the first of 28 double-shell radioactive waste storage tanks constructed at the U. S. Department of Energy’s Hanford Site, near Richland, WA. The tank was completed in 1970, and entered service in 1971. In August, 2012, an accumulation of material was discovered at two sites on the floor of the annulus that separates the primary tank from the secondary liner. The material was sampled and determined to originate from the primary tank. This paper summarizes the changes in leak behavior that have occurred during the past two years, inspections to determine the capability of the secondary linermore » to continue safely containing the leakage, and the initial results of testing to determine the leak mechanism.« less

  19. Martian neutron leakage spectra

    NASA Astrophysics Data System (ADS)

    Drake, D. M.; Feldman, W. C.; Jakosky, B. M.

    1988-06-01

    A high-energy nucleon-meson transport code is used to calculate energy spectra of Martian leakage neutrons. Four calculations are used to simulate a uniform surface layer containing various amounts of water, different burial depths of a 50 percent water layer underneath a 1 percent water layer, changing atmospheric pressure, and a thick carbon dioxide ice sheet overlying a "dirty" water ice sheet. Calculated spectra at energies less than about 1000 eV were fitted by a superposition of thermal and epithermal functions having four free parameters, two of which (thermal and epithermal amplitudes) were found to vary systematically and to specify uniquely the configuration in each of the series. Parameter variations depend on the composition of the assumed surface layers through the average atomic mass and the macroscopic scattering and absorption cross sections. It is concluded that measurements of leakage neutron spectra should allow determination of the hydrogen content of surface layers buried to depths up to about 100 g/sq. cm and determination of the thickness of a polar dry ice cap up to a thickness of about 250 g/sq. cm.

  20. Hydrophobic cyanine dye-doped micelles for optical in vivo imaging of plasma leakage and vascular disruption.

    PubMed

    Botz, Bálint; Bölcskei, Kata; Kemény, Ágnes; Sándor, Zoltán; Tékus, Valéria; Sétáló, György; Csepregi, Janka; Mócsai, Attila; Pintér, Erika; Kollár, László; Helyes, Zsuzsanna

    2015-01-01

    Vascular leakage is an important feature of various disease conditions. In vivo optical imaging provides a great opportunity for the evaluation of this phenomenon. In the present study, we focus on the development and validation of a near-infrared (NIR) imaging formula to allow reliable, cost-efficient evaluation of vascular leakage in diverse species using the existing small-animal fluorescence imaging technology. IR-676, a moderately hydrophobic NIR cyanine dye, was doped into self-assembling aqueous micelles using a widely employed and safe nonionic emulsifier (Kolliphor HS 15), and was tested in several acute and chronic inflammatory disease models in both mice and rats. The imaging formula is stable and exerts no acute toxic effects in vitro. It accumulated specifically in the inflamed regions in all models, which could be demonstrated by both conventional epifluorescence imaging, and fluorescence tomography both as a standalone technique and also by merging it with computed tomography scans. Ex vivo verification of dye accumulation by confocal fluorescence microscopy was also possible. The present formula allows sensitive and specific detection of inflammatory plasma leakage in diverse models. Its potential for imaging larger animals was also demonstrated. IR-676-doped micelles offer an excellent opportunity to image inflammatory vascular leakage in various models and species.

  1. Determination of canal leakage potential using continuous resistivity profiling techniques, Interstate and Tri-State Canals, western Nebraska and eastern Wyoming, 2004

    USGS Publications Warehouse

    Ball, Lyndsay B.; Kress, Wade H.; Steele, Gregory V.; Cannia, James C.; Andersen, Michael J.

    2006-01-01

    In the North Platte River Basin, a ground-water model is being developed to evaluate the effectiveness of using water leakage from selected irrigation canal systems to enhance ground-water recharge. The U.S. Geological Survey, in cooperation with the North Platte Natural Resources District, used land-based capacitively coupled and water-borne direct-current continuous resistivity profiling techniques to map the lithology of the upper 8 meters and to interpret the relative canal leakage potential of 110 kilometers of the Interstate and Tri-State Canals in western Nebraska and eastern Wyoming. Lithologic descriptions from 25 test holes were used to evaluate the effectiveness of both techniques for indicating relative grain size. An interpretive color scale was developed that symbolizes contrasting resistivity features indicative of different grain-size categories. The color scale was applied to the vertically averaged resistivity and used to classify areas of the canals as having either high, moderate, or low canal leakage potential. When results were compared with the lithologic descriptions, both land-based and water-borne continuous resistivity profiling techniques were determined to be effective at differentiating coarse-grained from fine-grained sediment. Both techniques were useful for producing independent, similar interpretations of canal leakage potential.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher Liner

    The objective of our work is graduate and undergraduate student training related to improved 3D seismic technology that addresses key challenges related to monitoring movement and containment of CO{sub 2}, specifically better quantification and sensitivity for mapping of caprock integrity, fractures, and other potential leakage pathways. We utilize data and results developed through previous DOE-funded CO{sub 2} characterization project (DE-FG26-06NT42734) at the Dickman Field of Ness County, KS. Dickman is a type locality for the geology that will be encountered for CO{sub 2} sequestration projects from northern Oklahoma across the U.S. midcontinent to Indiana and Illinois. Since its discovery inmore » 1962, the Dickman Field has produced about 1.7 million barrels of oil from porous Mississippian carbonates with a small structural closure at about 4400 ft drilling depth. Project data includes 3.3 square miles of 3D seismic data, 142 wells, with log, some core, and oil/water production data available. Only two wells penetrate the deep saline aquifer. In a previous DOE-funded project, geological and seismic data were integrated to create a geological property model and a flow simulation grid. We believe that sequestration of CO{sub 2} will largely occur in areas of relatively flat geology and simple near surface, similar to Dickman. The challenge is not complex geology, but development of improved, lower-cost methods for detecting natural fractures and subtle faults. Our project used numerical simulation to test methods of gathering multicomponent, full azimuth data ideal for this purpose. Our specific objectives were to apply advanced seismic methods to aide in quantifying reservoir properties and lateral continuity of CO{sub 2} sequestration targets. The purpose of the current project is graduate and undergraduate student training related to improved 3D seismic technology that addresses key challenges related to monitoring movement and containment of CO{sub 2}, specifically better quantification and sensitivity for mapping of caprock integrity, fractures, and other potential leakage pathways. Specifically, our focus is fundamental research on (1) innovative narrow-band seismic data decomposition and interpretation, and (2) numerical simulation of advanced seismic data (multi-component, high density, full azimuth data) ideal for mapping of cap rock integrity and potential leakage pathways.« less

  3. Preliminary investigation tests of novel antifungal topical aerosol

    PubMed Central

    Kapadia, Monali M.; Solanki, S. T.; Parmar, V.; Thosar, M. M.; Pancholi, S. S.

    2012-01-01

    Spray formulation can minimize pain and irritation experience during the application of conventional dosage forms. Econazole Nitrate is an active ingredient of the aerosol concentrate to be used for twice-daily application because of its long durability in the superficial layers of the fungal infected skin. The aim of this study is preliminary investigation of Econazole Nitrate spray by varying the concentrations of different constituents of the spray. The ratios of Propylene glycol (PG) and isopropyl myristate (IPM) were selected as independent variables in 22 full factorial designs, keeping the concentration of solvent, co-solvent and propellant LPG constant. Aerosol also contained Ethanol as solvent and Isopropyl alcohol as co-solvent. All ingredients of the aerosol were packaged in an aluminum container fitted with continuous-spray valves. Physical properties evaluated for the Econazole Nitrate spray included delivery rate, delivery amount, pressure, minimum fill, leakage, flammability, spray patterns, particle image and plume angle. Glass containers were used to study incompatibility between concentrate and propellant due to the ease of visible inspection. Isopropyl myristate at lower concentrate showed turbidity, while at high concentration it met the requirements for aerosol and produced Econazole Nitrate spray with expected characteristics. PMID:23066214

  4. Portable fixture facilitates pressure testing of instrumentation fittings

    NASA Technical Reports Server (NTRS)

    Olson, G. A.

    1967-01-01

    Portable fixture facilitates pressure testing to detect possible leaks in instrumentation fittings mounted on tank bulkheads. It uses a vacuum cup which seals a pressure regulator adapter around one side of the fitting to be pressure tested. Leakage is detected with a gas sniffer.

  5. Multilayer Piezoelectric Stack Actuator Characterization

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Jones, Christopher M.; Aldrich, Jack B.; Blodget, Chad; Bao, Xioaqi; Badescu, Mircea; Bar-Cohen, Yoseph

    2008-01-01

    Future NASA missions are increasingly seeking to use actuators for precision positioning to accuracies of the order of fractions of a nanometer. For this purpose, multilayer piezoelectric stacks are being considered as actuators for driving these precision mechanisms. In this study, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and extreme temperatures and voltages. AC signal testing included impedance, capacitance and dielectric loss factor of each actuator as a function of the small-signal driving sinusoidal frequency, and the ambient temperature. DC signal testing includes leakage current and displacement as a function of the applied DC voltage. The applied DC voltage was increased to over eight times the manufacturers' specifications to investigate the correlation between leakage current and breakdown voltage. Resonance characterization as a function of temperature was done over a temperature range of -180C to +200C which generally exceeded the manufacturers' specifications. In order to study the lifetime performance of these stacks, five actuators from one manufacturer were driven by a 60volt, 2 kHz sine-wave for ten billion cycles. The tests were performed using a Lab-View controlled automated data acquisition system that monitored the waveform of the stack electrical current and voltage. The measurements included the displacement, impedance, capacitance and leakage current and the analysis of the experimental results will be presented.

  6. Flying After Conducting an Aircraft Excessive Cabin Leakage Test.

    PubMed

    Houston, Stephen; Wilkinson, Elizabeth

    2016-09-01

    Aviation medical specialists should be aware that commercial airline aircraft engineers may undertake a 'dive equivalent' operation while conducting maintenance activities on the ground. We present a worked example of an occupational risk assessment to determine a minimum safe preflight surface interval (PFSI) for an engineer before flying home to base after conducting an Excessive Cabin Leakage Test (ECLT) on an unserviceable aircraft overseas. We use published dive tables to determine the minimum safe PFSI. The estimated maximum depth acquired during the procedure varies between 10 and 20 fsw and the typical estimated bottom time varies between 26 and 53 min for the aircraft types operated by the airline. Published dive tables suggest that no minimum PFSI is required for such a dive profile. Diving tables suggest that no minimum PFSI is required for the typical ECLT dive profile within the airline; however, having conducted a risk assessment, which considered peak altitude exposure during commercial flight, the worst-case scenario test dive profile, the variability of interindividual inert gas retention, and our existing policy among other occupational groups within the airline, we advised that, in the absence of a bespoke assessment of the particular circumstances on the day, the minimum PFSI after conducting ECLT should be 24 h. Houston S, Wilkinson E. Flying after conducting an aircraft excessive cabin leakage test. Aerosp Med Hum Perform. 2016; 87(9):816-820.

  7. Actively controlled shaft seals for aerospace applications

    NASA Technical Reports Server (NTRS)

    Salant, Richard F.

    1993-01-01

    An electronically controlled mechanical seal for use as the purge gas seal in a liquid oxygen turbo pump has been fabricated and tested under transient operating conditions. The thickness of the lubricating film is controlled by adjusting the coning of the carbon face. This is accomplished by applying a voltage to a piezoelectric actuator to which the carbon face is bonded. The seal has been operated with a closed-loop control system that utilizes either the leakage rate or the seal face temperature as the feedback. Both speed and pressure transients have been imposed on the seal. The transient tests have demonstrated that the seal is capable of maintaining low leakage rates while limiting the face temperatures.

  8. 46 CFR 160.174-17 - Approval testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... water. After one hour the membrane must continue to support the column of water with no leakage. (f... the exterior of the aid must be tested. Any material that is a composite formed of two or more...

  9. 46 CFR 160.174-17 - Approval testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... water. After one hour the membrane must continue to support the column of water with no leakage. (f... the exterior of the aid must be tested. Any material that is a composite formed of two or more...

  10. 46 CFR 160.174-17 - Approval testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... water. After one hour the membrane must continue to support the column of water with no leakage. (f... the exterior of the aid must be tested. Any material that is a composite formed of two or more...

  11. 46 CFR 160.174-17 - Approval testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... water. After one hour the membrane must continue to support the column of water with no leakage. (f... the exterior of the aid must be tested. Any material that is a composite formed of two or more...

  12. 46 CFR 160.174-17 - Approval testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... water. After one hour the membrane must continue to support the column of water with no leakage. (f... the exterior of the aid must be tested. Any material that is a composite formed of two or more...

  13. Recovery Characteristics of Anomalous Stress-Induced Leakage Current of 5.6 nm Oxide Films

    NASA Astrophysics Data System (ADS)

    Inatsuka, Takuya; Kumagai, Yuki; Kuroda, Rihito; Teramoto, Akinobu; Sugawa, Shigetoshi; Ohmi, Tadahiro

    2012-04-01

    Anomalous stress-induced leakage current (SILC), which has a much larger current density than average SILC, causes severe bit error in flash memories. To suppress anomalous SILC, detailed evaluations are strongly required. We evaluate the characteristics of anomalous SILC of 5.6 nm oxide films using a fabricated array test pattern, and recovery characteristics are observed. Some characteristics of typical anomalous cells in the time domain are measured, and the recovery characteristics of average and anomalous SILCs are examined. Some of the anomalous cells have random telegraph signals (RTSs) of gate leakage current, which are characterized as discrete and random switching phenomena. The dependence of RTSs on the applied electric field is investigated, and the recovery tendency of anomalous SILC with and without RTSs are also discussed.

  14. Leakage Currents in Low-Voltage PME and BME Ceramic Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2015-01-01

    Introduction of BME capacitors to high-reliability electronics as a replacement for PME capacitors requires better understanding of changes in performance and reliability of MLCCs to set justified screening and qualification requirements. In this work, absorption and leakage currents in various lots of commercial and military grade X7R MLCCs rated to 100V and less have been measured to reveal difference in behavior of PME and BME capacitors in a wide range of voltages and temperatures. Degradation of leakage currents and failures in virgin capacitors and capacitors with introduced cracks has been studied at different voltages and temperatures during step stress highly accelerated life testing. Mechanisms of charge absorption, conduction and degradation have been discussed and a failure model in capacitors with defects suggested.

  15. Effect of Mechanical Stresses on Characteristics of Chip Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2007-01-01

    The effect of compressive mechanical stresses on chip solid tantalum capacitors is investigated by monitoring characteristics of different part types under axial and hydrostatic stresses. Depending on part types, an exponential increase of leakage currents was observed when stresses exceeded 10 MPa to 40 MPa. For the first time, reversible variations of leakage currents (up to two orders of magnitude) with stress have been demonstrated. Mechanical stresses did not cause significant changes of AC characteristics of the capacitors, whereas breakdown voltages measured during the surge current testing decreased substantially indicating an increased probability of failures of stressed capacitors in low impedance applications. Variations of leakage currents are explained by a combination of two mechanisms: stress-induced scintillations and stress-induced generation of electron traps in the tantalum pentoxide dielectric.

  16. Development of gas-to-gas lift pad dynamic seals, volumes 1 and 2

    NASA Technical Reports Server (NTRS)

    Pope, A. N.; Pugh, D. W.

    1987-01-01

    Dynamic tests were performed on self acting (hydrodynamic) carbon face rotary shaft seals to assess their potential, relative to presently used labyrinth seals, for improving performance of aircraft gas turbine engines by reducing air leakage flow rate at compressor end seal locations. Three self acting bearing configurations, designed to supply load support at the interface of the stationary carbon seal and rotating seal race, were tested. Two configurations, the shrouded taper and shrouded flat step, were incorporated on the face of the stationary carbon seal element. The third configuration, inward pumping spiral grooves, was incorporated on the hard faced surface of the rotating seal race. Test results demonstrated seal leakage air flow rates from 75 to 95% lower that can be achieved with best state-of-the-art labyrinth designs and led to identification of the need for a more geometrically stable seal design configuration which is presently being manufactured for subsequent test evaluation.

  17. Theoretical investigation of metal magnetic memory testing technique for detection of magnetic flux leakage signals from buried defect

    NASA Astrophysics Data System (ADS)

    Xu, Kunshan; Qiu, Xingqi; Tian, Xiaoshuai

    2018-01-01

    The metal magnetic memory testing (MMMT) technique has been extensively applied in various fields because of its unique advantages of easy operation, low cost and high efficiency. However, very limited theoretical research has been conducted on application of MMMT to buried defects. To promote study in this area, the equivalent magnetic charge method is employed to establish a self-magnetic flux leakage (SMFL) model of a buried defect. Theoretical results based on the established model successfully capture basic characteristics of the SMFL signals of buried defects, as confirmed via experiment. In particular, the newly developed model can calculate the buried depth of a defect based on the SMFL signals obtained via testing. The results show that the new model can successfully assess the characteristics of buried defects, which is valuable in the application of MMMT in non-destructive testing.

  18. Experimental studies and performance analyses on polyurethane and nitrile rubber rod seals

    NASA Astrophysics Data System (ADS)

    Mirza, M.; Temiz, V.; Kamburoǧlu, E.

    2012-09-01

    The aim of this study is to determine the friction and leakage properties of rod seals made of polyethylene and nitrile rubber with different design geometries, under various pressure and lubricating oil viscosity conditions, in order to make assumptions about their general sealing characteristics and their pros and cons under certain working conditions that involve a range of fluid pressures. The test specimens consist of commercial rod seals of various designs and materials and were mounted on a hard chrome coated shaft subject to reciprocating motion. The test rig is capable of measuring friction force by means of strain measurements on a load cell transmitting the linear motion of a screw shaft to the test shaft. The test results of the reciprocating rod seal samples were evaluated according to leakage amount and friction resistance as a function of materials, design geometries and fluid pressures as well as the lubricating oil viscosity.

  19. A laboratory validation study of the time-lapse oscillatory pumping test concept for leakage detection in geological repositories

    NASA Astrophysics Data System (ADS)

    Sun, A. Y.; Islam, A.; Lu, J.

    2017-12-01

    Time-lapse oscillatory pumping test (OPT) has been introduced recently as a pressure-based monitoring technique for detecting potential leakage in geologic repositories. By routinely conducting OPT at a number of pulsing frequencies, a site operator may identify the potential anomalies in the frequency domain, alleviating the ambiguity caused by reservoir noise and improving the signal-to-noise ratio. Building on previous theoretical and field studies, this work performed a series of laboratory experiments to validate the concept of time-lapse OPT using a custom made, stainless steel tank under relatively high pressures ( 120psi). The experimental configuration simulates a miniature geologic storage repository consisting of three layers (i.e., injection zone, caprock, and above-zone aquifer). Results show that leakage in the injection zone led to deviations in the power spectrum of observed pressure data, and the amplitude of which also increases with decreasing pulsing frequencies. The experimental results were further analyzed by developing a 3D flow model, using which the model parameters were estimated through frequency domain inversion.

  20. Gas distribution equipment in hydrogen service - Phase II

    NASA Technical Reports Server (NTRS)

    Jasionowski, W. J.; Huang, H. D.

    1980-01-01

    The hydrogen permeability of three different types of commercially available natural gas polyethylene pipes was determined. Ring tensile tests were conducted on permeability-exposed and as-received samples. Hydrogen-methane leakage experiments were also performed. The results show no selective leakage of hydrogen via Poiseuille, turbulent, or orifice flow (through leaks) on the distribution of blends of hydrogen and methane. The data collected show that the polyethylene pipe is 4 to 6 times more permeable to hydrogen than to methane.

  1. Binding and Leakage of Barium in Alginate Microbeads

    PubMed Central

    Mørch, Yrr A.; Qi, Meirigeng; Gundersen, Per Ole M.; Formo, Kjetil; Lacik, Igor; Skjåk-Bræk, Gudmund; Oberholzer, Jose; Strand, Berit L.

    2013-01-01

    Microbeads of alginate cross-linked with Ca2+ and/or Ba2+ are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared to high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. In order to reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. PMID:22700168

  2. Binding and leakage of barium in alginate microbeads.

    PubMed

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  3. Peroxidative permeabilization of liposomes induced by cytochrome c/cardiolipin complex.

    PubMed

    Firsov, Alexander M; Kotova, Elena A; Korepanova, Evgeniya A; Osipov, Anatoly N; Antonenko, Yuri N

    2015-03-01

    Interaction of cytochrome c with mitochondrial cardiolipin converting this electron transfer protein into peroxidase is accepted to play an essential role in apoptosis. Cytochrome c/cardiolipin peroxidase activity was found here to cause leakage of carboxyfluorescein, sulforhodamine B and 3-kDa (but not 10-kDa) fluorescent dextran from liposomes. A marked decrease in the amplitude of the autocorrelation function was detected with a fluorescence correlation spectroscopy setup upon incubation of dye-loaded cardiolipin-containing liposomes with cytochrome c and H2O2, thereby showing release of fluorescent markers from liposomes. The cytochrome c/H2O2-induced liposome leakage was suppressed upon increasing the ionic strength, in contrast to the leakage provoked by Fe/ascorbate, suggesting that the binding of cyt c to negatively-charged membranes was required for the permeabilization process. The cyt c/H2O2-induced liposome leakage was abolished by cyanide presumably competing with H2O2 for coordination with the central iron atom of the heme in cyt c. The cytochrome c/H2O2 permeabilization activity was substantially diminished by antioxidants (trolox, butylhydroxytoluene and quercetin) and was precluded if fully saturated tetramyristoyl-cardiolipin was substituted for bovine heart cardiolipin. These data favor the involvement of oxidized cardiolipin molecules in membrane permeabilization resulting from cytochrome c/cardiolipin peroxidase activity. In agreement with previous observations, high concentrations of cyt c induced liposome leakage in the absence of H2O2, however this process was not sensitive to antioxidants and cyanide suggesting direct membrane poration by the protein without the involvement of lipid peroxidation. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-11-01

    While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While thismore » air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.« less

  5. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    PubMed

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical solution, preventing possible prefilled syringe plunger movement during container closure integrity testing execution, is presented as well. The growing need to meet sterile drug products' regulatory, quality, and safety expectations has progressively driven new developments and improvements both in container closure integrity testing methods and in the respective equipment, over the last years. Indeed, container closure integrity testing establishes the container closure system capability to provide required protection to the drug product and to demonstrate maintenance of product sterility over its shelf life. This article describes the development of four container closure integrity testing approaches for the evaluation of glass prefilled syringe closure integrity, including two destructive (pharmacopoeial and Novartis specific dye ingress test) and two non-destructive (vacuum decay and high-voltage leak detection) methods. The important finding from the validation of comparative studies was that the vacuum decay method resulted in the most effective, reliable and repeatable detection of defective samples, whether the defect was exposed to sterile water, to drug product, or to air. Complete sets of known defects were created for this purpose (5 μm, 10 μm, 20 μm certified leakages by laser drilled holes and capillary tubes). All investigations and studies were conducted at Bonfiglioli Engineering S.r.l. (Vigarano Pieve, Ferrara, Italy) and at Novartis Vaccines (Sovicille, Siena, Italy). © PDA, Inc. 2015.

  6. Effects of flow separation and cove leakage on pressure and heat-transfer distributions along a wing-cove-elevon configuration at Mach 6.9. [Langley 8-ft high temperature tunnel test

    NASA Technical Reports Server (NTRS)

    Deveikis, W. D.

    1983-01-01

    External and internal pressure and cold-wall heating-rate distributions were obtained in hypersonic flow on a full-scale heat-sink representation of the space shuttle orbiter wing-elevon-cove configuration in an effort to define effects of flow separation on cove aerothermal environment as a function of cove seal leak area, ramp angle, and free-stream unit Reynolds number. Average free-stream Mach number from all tests was 6.9; average total temperature from all tests was 3360 R; free-stream dynamic pressure ranged from about 2 to 9 psi; and wing angle of attack was 5 deg (flow compression). For transitional and turbulent flow separation, increasing cove leakage progressively increased heating rates in the cove. When ingested mass flow was sufficient to force large reductions in extent of separation, increasing cove leakage reduced heating rates in the cove to those for laminar attached flow. Cove heating-rate distributions calculated with a method that assumed laminar developing channel flow agreed with experimentally obtained distributions within root-mean-square differences that varied between 11 and 36 percent where cove walls were parallel for leak areas of 50 and 100 percent.

  7. Fusogenic activity of PEGylated pH-sensitive liposomes.

    PubMed

    Vanić, Zeljka; Barnert, Sabine; Süss, Regine; Schubert, Rolf

    2012-06-01

    The aim of this study was to investigate the fusogenic properties of poly(ethylene glycol) (PEG)ylated dioleoylphosphatidylethanolamine/cholesteryl hemisuccinate (DOPE/CHEMS) liposomes. These pH-sensitive liposomes were prepared by incorporating two different PEG lipids: distearoylphosphatidylethanolamine (DSPE)-PEG₂₀₀₀ was mixed with the liposomal lipids using the conventional method, whereas sterol-PEG₁₁₀₀ was inserted into the outer monolayer of preformed vesicles. Both types of PEGylated liposomes were characterized and compared for their entrapment efficiency, zeta potential and size, and were tested in vitro for pH sensitivity by means of proton-induced leakage and membrane fusion activity. To mimic the routes of intracellular delivery, fusion between pH-sensitive liposomes and liposomes designed to simulate the endosomal membrane was studied. Our investigations confirmed that DOPE/CHEMS liposomes were capable of rapidly releasing calcein and of fusing upon acidification. However, after incorporation of DSPE-PEG₂₀₀₀ or sterol-PEG₁₁₀₀ into the membrane, pH sensitivity was significantly reduced; as the mol ratio of PEG-lipid was increased, the ability to fuse was decreased. Comparison between two different PEGylated pH-sensitive liposomes showed that only vesicles containing 0.6 mol% sterol-PEG₁₁₀₀ in the outer monolayer were still capable of fusing with the endosome-like liposomes and showing leakage of calcein at pH 5.5.

  8. Design, development, fabrication and delivery of register and multiplexer units. [CMOS monolithic chip development

    NASA Technical Reports Server (NTRS)

    Feller, A.; Lombardi, T.

    1978-01-01

    Several approaches for implementing the register and multiplexer unit into two CMOS monolithic chip types were evaluated. The CMOS standard cell array technique was selected and implemented. Using this design automation technology, two LSI CMOS arrays were designed, fabricated, packaged, and tested for proper static, functional, and dynamic operation. One of the chip types, multiplexer register type 1, is fabricated on a 0.143 x 0.123 inch chip. It uses nine standard cell types for a total of 54 standard cells. This involves more than 350 transistors and has the functional equivalent of 111 gates. The second chip, multiplexer register type 2, is housed on a 0.12 x 0.12 inch die. It uses 13 standard cell types, for a total of 42 standard cells. It contains more than 300 transistors, the functional equivalent of 112 gates. All of the hermetically sealed units were initially screened for proper functional operation. The static leakage and the dynamic leakage were measured. Dynamic measurements were made and recorded. At 10 V, 14 megabit shifting rates were measured on multiplexer register type 1. At 5 V these units shifted data at a 6.6 MHz rate. The units were designed to operate over the 3 to 15 V operating range and over a temperature range of -55 to 125 C.

  9. Hydrogeology and water quality of the Floridan aquifer system and effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Fort Stewart, Georgia

    USGS Publications Warehouse

    Clarke, John S.; Cherry, Gregory C.; Gonthier, Gerard

    2011-01-01

    Test drilling, field investigations, and digital modeling were completed at Fort Stewart, GA, during 2009?2010, to assess the geologic, hydraulic, and water-quality characteristics of the Floridan aquifer system and evaluate the effect of Lower Floridan aquifer (LFA) pumping on the Upper Floridan aquifer (UFA). This work was performed pursuant to the Georgia Environmental Protection Division interim permitting strategy for new wells completed in the LFA that requires simulation to (1) quantify pumping-induced aquifer leakage from the UFA to LFA, and (2) identify the equivalent rate of UFA pumping that would produce the same maximum drawdown in the UFA that anticipated pumping from LFA well would induce. Field investigation activities included (1) constructing a 1,300-foot (ft) test boring and well completed in the LFA (well 33P028), (2) constructing an observation well in the UFA (well 33P029), (3) collecting drill cuttings and borehole geophysical logs, (4) collecting core samples for analysis of vertical hydraulic conductivity and porosity, (5) conducting flowmeter and packer tests in the open borehole within the UFA and LFA, (6) collecting depth-integrated water samples to assess basic ionic chemistry of various water-bearing zones, and (7) conducting aquifer tests in new LFA and UFA wells to determine hydraulic properties and assess interaquifer leakage. Using data collected at the site and in nearby areas, model simulation was used to assess the effects of LFA pumping on the UFA. Borehole-geophysical and flowmeter data indicate the LFA at Fort Stewart consists of limestone and dolomitic limestone between depths of 912 and 1,250 ft. Flowmeter data indicate the presence of three permeable zones at depth intervals of 912-947, 1,090-1,139, and 1,211?1,250 ft. LFA well 33P028 received 50 percent of the pumped volume from the uppermost permeable zone, and about 18 and 32 percent of the pumped volume from the middle and lowest permeable zones, respectively. Chemical constituent concentrations increased with depth, and water from all permeable zones contained sulfate at concentrations that exceeded the U.S. Environmental Protection Agency secondary maximum contaminant level of 250 milligrams per liter. A 72-hour aquifer test pumped LFA well 33P028 at 740 gallons per minute (gal/min), producing about 39 ft of drawdown in the pumped well and about 0.4 foot in nearby UFA well 33P029. Simulation using the U.S. Geological Survey finite-difference code MODFLOW was used to determine long-term, steady-state flow in the Floridan aquifer system, assuming the LFA well was pumped continuously at a rate of 740 gal/min. Simulated steady-state drawdown in the LFA was identical to that observed in pumped LFA well 33P028 at the end of the 72-hour test, with values larger than 1 ft extending 4.4 square miles symmetrically around the pumped well. Simulated steady-state drawdown in the UFA resulting from pumping in LFA well 33P028 exceeded 1 ft within a 1.4-square-mile circular area, and maximum drawdown in the UFA was 1.1 ft. Leakage from the UFA through the Lower Floridan confining unit contributed about 98 percent of the water to the well; lateral flow from specified-head model boundaries contributed about 2 percent. About 80 percent of the water supplied to LFA well 33P028 originated from within 1 mile of the well, and 49 percent was derived from within 0.5 mile of the well. Vertical hydraulic gradients and vertical leakage are progressively higher near the LFA pumped well which results in a correspondingly higher contribution of water from the UFA to the pumped well at distances closer to the pumped well. Simulated pumping-induced interaquifer leakage from the UFA to the LFA totaled 725 gal/min (1.04 million gallons per day), whereas simulated pumping at 205 gal/min (0.3 million gallons per day) from UFA well 33P029 produced the equivalent maximum drawdown as pumping LFA well 33P028 at 740 gal/min during the aquifer test. This equivalent pumpin

  10. 76 FR 17712 - In the Matter of Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... completed to the Commission's satisfaction: (1) The tritiated groundwater remediation process; (2) the soil remediation process scheduled to take place during the refueling outage, to remove soil containing tritium and... leakage into the surrounding soil, and therefore to the groundwater, from an unsealed joint in the...

  11. Cable Feedthrough Between Liquid Oxygen And Ambient

    NASA Technical Reports Server (NTRS)

    Myers, Don A.

    1992-01-01

    Encapsulant and back pressure provide double protection. Cable-feedthrough tube between ambient air and interior of vessel containing liquid oxygen protects external instrumentation and cable from oxygen. Cable in tube surrounded by potting compound. Provides flow of gaseous nitrogen to dilute oxidant and makes it harmless in case of leakage through crack in potting compound.

  12. Design of evaporator of spacelab refrigerator/freezer

    NASA Technical Reports Server (NTRS)

    Hye, A.

    1985-01-01

    An Evaporator has been designed for NASA-Johnson Space Center Life Sciences to conduct experiments in Spacelab mission SLS-1 using different samples such as blood, urine, human tissues etc. Two units will fly - one as a Refrigerator (4 C) and the other as a Freezer (-22 C). The evaporator tube is dip brazed on a grooved flat plate. Aluminum heat sink is dip brazed on the other side of the plate. Freon R5O2 is pumped through the tube and air is circulated over the finned surface to transfer heat. As freon 5O2 is considered toxic, the whole freon tube is covered with an evaporator cover to contain any freon leakage to avoid exposure to crew members. This containment is under vacuum and this pressure is monitored along with the freon pressure to determine freon leakage so that necessary steps can be taken to stop contamination of the spacelab air. An stress analysis has been done and it is found to have adequate safety margin to meet the requirements of NASA safety and reliability standards.

  13. 49 CFR 178.356-3 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Tests. 178.356-3 Section 178.356-3 Transportation... Packagings for Class 7 (Radioactive) Materials § 178.356-3 Tests. (a) Leakage test—Each inner liner assembly... must be held for at least 30 seconds. Liners failing to pass this test may not be used until repairs...

  14. 49 CFR 178.356-3 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Tests. 178.356-3 Section 178.356-3 Transportation... Packagings for Class 7 (Radioactive) Materials § 178.356-3 Tests. (a) Leakage test—Each inner liner assembly... must be held for at least 30 seconds. Liners failing to pass this test may not be used until repairs...

  15. 49 CFR 178.356-3 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Tests. 178.356-3 Section 178.356-3 Transportation... Packagings for Class 7 (Radioactive) Materials § 178.356-3 Tests. (a) Leakage test—Each inner liner assembly... must be held for at least 30 seconds. Liners failing to pass this test may not be used until repairs...

  16. 49 CFR 178.356-3 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tests. 178.356-3 Section 178.356-3 Transportation... Packagings for Class 7 (Radioactive) Materials § 178.356-3 Tests. (a) Leakage test—Each inner liner assembly... must be held for at least 30 seconds. Liners failing to pass this test may not be used until repairs...

  17. Fatigue and creep to leak tests of proton exchange membranes using pressure-loaded blisters

    NASA Astrophysics Data System (ADS)

    Li, Yongqiang; Dillard, David A.; Case, Scott W.; Ellis, Michael W.; Lai, Yeh-Hung; Gittleman, Craig S.; Miller, Daniel P.

    In this study, three commercially available proton exchange membranes (PEMs) are biaxially tested using pressure-loaded blisters to characterize their resistance to gas leakage under either static (creep) or cyclic fatigue loading. The pressurizing medium, air, is directly used for leak detection. These tests are believed to be more relevant to fuel cell applications than quasi-static uniaxial tensile-to-rupture tests because of the use of biaxial cyclic and sustained loading and the use of gas leakage as the failure criterion. They also have advantages over relative humidity cycling test, in which a bare PEM or catalyst coated membrane is clamped with gas diffusion media and flow field plates and subjected to cyclic changes in relative humidity, because of the flexibility in allowing controlled mechanical loading and accelerated testing. Nafion ® NRE-211 membranes are tested at three different temperatures and the time-temperature superposition principle is used to construct stress-lifetime master curve. Tested at 90 °C, 2%RH extruded Ion Power ® N111-IP membranes have a longer lifetime than Gore™-Select ® 57 and Nafion ® NRE-211 membranes.

  18. Brush Seal Performance and Durability Issues Based on T-700 Engine Test Results

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.

    1994-01-01

    The integrity and performance of brush seals have been established. Severe bench and engine tests have shown high initial wear or run-in rates, material smearing at the interface, and bristle and rub-runner wear, but the brush seals did not fail. Short-duration (46 hr) experimental T-700 engine testing of the compressor discharge seal established over 1-percent engine performance gain (brush versus labyrinth). Long-term gains were established only as leakage comparisons, with the brush at least 20 percent better at controlling leakage. Long-term materials issues, such as wear and ultimately seal life, remain to be resolved. Future needs are cited for materials and analysis tools that account for heat generation, thermomechanical behavior, and tribological pairing to enable original equipment manufacturers to design high-temperature, high-surface-speed seals with confidence.

  19. Antimicrobial cotton textiles with robust superhydrophobicity via plasma for oily water separation

    NASA Astrophysics Data System (ADS)

    Zhang, Ming; Pang, Jiuyin; Bao, Wenhui; Zhang, Wenbo; Gao, He; Wang, Chengyu; Shi, Junyou; Li, Jian

    2017-10-01

    During these decades, functional materials are facing the severe challenge of their weak surface structure. To solve this problem, plasma technology and spraying technology were utilized to improve the bonding effect between cotton substrates and coating structures. Herein, silica/silver nanoparticles (SiO2/Ag NPs) were prepared and introduced to the nano-/micro- structures on sample surface by spraying technology in the existence of polyurethane adhesive. Then the circles of spraying procedure containing adhesive and SiO2/Ag NPs had been discussed. After further fluorination, the samples still displayed an excellent waterproof property even after abrasion test with sand paper and various washing test by its solvent-acetone or harsh liquids with strong acidity/alkalinity, indicating their robust surfaces structures. More importantly, this product displayed the outstanding performance no matter in laboratory oil/water filtration or the extensive oil leakage and spill. At last, our modification also endowed the cotton sample with great antimicrobial property.

  20. Space shuttle main engine definition (phase B). Volume 5: Valves and interconnects. [for space shuttle

    NASA Technical Reports Server (NTRS)

    Schultz, D. F.

    1971-01-01

    The steady state thermodynamic cycle balance of the single preburner staged combustion engine, coupled with dynamic transient analyses, dictated in detail the location and requirements for each valve defined in this volume. Valve configuration selections were influenced by overall engine and vehicle system weight and failure mode determinations. Modulating valve actuators are external to the valve and are line replaceable. Development and satisfactory demonstration of a high pressure dynamic shaft seal has made this configuration practical. Pneumatic motor driven actuators that use engine pumped hydrogen gas as the working fluid are used. The helium control system is proposed as a module containing a cluster of solenoid actuated valves. The separable couplings and flanges are designed to assure minimum leakage with minimum coupling weight. The deflection of the seal surface in the flange is defined by finite element analysis that has been confirmed with test data. The seal design proposed has passed preliminary pressure cycling and thermal cycling tests.

  1. Performance of Metal and Polymeric O-Ring Seals during Beyond-Design-Basis Thermal Conditions.

    PubMed

    Yang, Jiann C; Hnetkovsky, Edward; Rinehart, Doris; Fernandez, Marco; Gonzalez, Felix; Borowsky, Joseph

    2017-04-01

    This paper summarizes the small scale thermal exposure test results of the performance of metallic and polymeric O-ring seals typically used in radioactive material transportation packages. Five different O-ring materials were evaluated: Inconel/silver, ethylene-propylene diene monomer (EPDM), polytetrafluoroethylene (PTFE), silicone, butyl, and Viton. The overall objective of this study is to provide test data and insights to the performance of these Oring seals when exposed to beyond-design-basis temperature conditions due to a severe fire. Tests were conducted using a small-scale stainless steel pressure vessel pressurized with helium to 2 bar or 5 bar at room temperature. The vessel was then heated in an electric furnace to temperatures up to 900 °C for a pre-determined period (typically 8 h to 9 h). The pressure drop technique was used to determine if leakage occurred during thermal exposure. Out of a total of 46 tests performed, leakage (loss of vessel pressure) was detected in 13 tests.

  2. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead.

    PubMed

    Wu, Jianbo; Fang, Hui; Li, Long; Wang, Jie; Huang, Xiaoming; Kang, Yihua; Sun, Yanhua; Tang, Chaoqing

    2017-01-21

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety.

  3. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead

    PubMed Central

    Wu, Jianbo; Fang, Hui; Li, Long; Wang, Jie; Huang, Xiaoming; Kang, Yihua; Sun, Yanhua; Tang, Chaoqing

    2017-01-01

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety. PMID:28117721

  4. An Evaluation of High Temperature Airframe Seals for Advanced Hypersonic Vehicles

    NASA Technical Reports Server (NTRS)

    DeMange, Jeffrey J.; Dunlap, Patrick H.; Steinetz, Bruce M.; Drlik, Gary J.

    2007-01-01

    High temperature seals are required for advanced hypersonic airframe applications. In this study, both spring tube thermal barriers and innovative wafer seal systems were evaluated under relevant hypersonic test conditions (temperatures, pressures, etc.) via high temperature compression testing and room temperature flow assessments. Thermal barriers composed of a Rene 41 spring tube filled with Saffil insulation and overbraided with a Nextel 312 sheath showed acceptable performance at 1500 F in both short term and longer term compression testing. Nextel 440 thermal barriers with Rene 41 spring tubes and Saffil insulation demonstrated good compression performance up to 1750 F. A silicon nitride wafer seal/compression spring system displayed excellent load performance at temperatures as high as 2200 F and exhibited room temperature leakage values that were only 1/3 those for the spring tube rope seals. For all seal candidates evaluated, no significant degradation in leakage resistance was noted after high temperature compression testing. In addition to these tests, a superalloy seal suitable for dynamic seal applications was optimized through finite element techniques.

  5. Performance of Metal and Polymeric O-Ring Seals during Beyond-Design-Basis Thermal Conditions*

    PubMed Central

    Yang, Jiann C.; Hnetkovsky, Edward; Rinehart, Doris; Fernandez, Marco; Gonzalez, Felix; Borowsky, Joseph

    2017-01-01

    This paper summarizes the small scale thermal exposure test results of the performance of metallic and polymeric O-ring seals typically used in radioactive material transportation packages. Five different O-ring materials were evaluated: Inconel/silver, ethylene-propylene diene monomer (EPDM), polytetrafluoroethylene (PTFE), silicone, butyl, and Viton. The overall objective of this study is to provide test data and insights to the performance of these Oring seals when exposed to beyond-design-basis temperature conditions due to a severe fire. Tests were conducted using a small-scale stainless steel pressure vessel pressurized with helium to 2 bar or 5 bar at room temperature. The vessel was then heated in an electric furnace to temperatures up to 900 °C for a pre-determined period (typically 8 h to 9 h). The pressure drop technique was used to determine if leakage occurred during thermal exposure. Out of a total of 46 tests performed, leakage (loss of vessel pressure) was detected in 13 tests. PMID:28503009

  6. A collimated detection system for assessing leakage dose from medical linear accelerators at the patient plane.

    PubMed

    Lonski, P; Taylor, M L; Franich, R D; Kron, T

    2014-03-01

    Leakage radiation from linear accelerators can make a significant contribution to healthy tissue dose in patients undergoing radiotherapy. In this work thermoluminescent dosimeters (LiF:Mg,Cu,P TLD chips) were used in a focused lead cone loaded with TLD chips for the purpose of evaluating leakage dose at the patient plane. By placing the TLDs at one end of a stereotactic cone, a focused measurement device is created; this was tested both in and out of the primary beam of a Varian 21-iX linac using 6 MV photons. Acrylic build up material of 1.2 cm thickness was used inside the cone and measurements made with either one or three TLD chips at a given distance from the target. Comparing the readings of three dosimeters in one plane inside the cone offered information regarding the orientation of the cone relative to a radiation source. Measurements in the patient plane with the linac gantry at various angles demonstrated that leakage dose was approximately 0.01% of the primary beam out of field when the cone was pointed directly towards the target and 0.0025% elsewhere (due to scatter within the gantry). No specific 'hot spots' (e.g., insufficient shielding or gaps at abutments) were observed. Focused cone measurements facilitate leakage dose measurements from the linac head directly at the patient plane and allow one to infer the fraction of leakage due to 'direct' photons (along the ray-path from the bremsstrahlung target) and that due to scattered photons.

  7. Impact of root canal preparation size and taper on coronal-apical micro-leakage using glucose penetration method

    PubMed Central

    Tabrizizadeh, Mehdi; Hekmati-Moghadam, Seyed-Hossein; Hakimian, Roqayeh

    2014-01-01

    Objectives: The purpose of this in vitro study was to assess the effect of root canal preparation size and taper on the amounts of glucose penetration. Material and Methods: For conducting this experimental study, eighty mandibular premolars with single straight canals were divided randomly into 2 experimental groups of 30 samples each and 2 control groups. Using K-files and the balance force technique, canals in group 1 were prepared apically to size 25 and coronally to size 2 Peesoreamer. Group 2 were instrumented apically and coronally to size 40 and size 6 Peesoreamer, respectively. Rotary instrumentation was accomplished in group 1; using size 25 and .04 tapered and in group 2, size 35 and .06 tapered Flex Master files. Canals were then obturated by lateral compaction of cold gutta-percha. Glucose penetration through root canal fillings was measured at 1, 8, 15, 22 and 30 days. Data were recorded as mmol/L and statistically analyzed with Mann-Whitney U test (P value=. 05). Results: In comparison to group 1, group 2 showed significant glucose leakage during the experimental period (P value < .0001). Also, in each experimental group, the amount of micro-leakage was significantly increased at the end of the study. Conclusions: Under the condition of this study, the amounts of micro-leakage through root canal fillings are directly related to the size and taper of root canal preparation and reducing the preparation size may lead to less micro-leakage. Key words:Dental leakage, root canal preparation, endodontics. PMID:25593654

  8. Dye leakage of four root end filling materials: effects of blood contamination.

    PubMed

    Torabinejad, M; Higa, R K; McKendry, D J; Pitt Ford, T R

    1994-04-01

    The purpose of this study was to compare the amount of dye leakage (in the presence versus absence of blood) in root end cavities filled with amalgam, Super EBA, IRM, and a mineral trioxide aggregate. After removing the anatomical crowns of 90 extracted human teeth, their roots were instrumented and obturated. Except for their apical 2 mm, the root surfaces were sealed with nail polish. After removal of the apical 2 to 3 mm of each root, a standardized root end cavity was prepared. Five root ends were filled with gutta-percha and no sealer, and another five root ends were filled with sticky wax. These served as positive and negative controls, respectively. The remaining 80 roots were divided into four equal groups and filled with the test materials. For each material, half of the root end cavities were dried prior to placing the filling material. The remaining half were filled after they were contaminated with blood. All 90 roots were then immediately placed in 1% methylene blue dye for 72 h. Finally, the roots were split and linear dye penetration was measured and statistically analyzed (analysis of variance). Presence or absence of blood had no significant effect on the amount of dye leakage. However, the results showed that there was a significant leakage difference between the root end filling materials (p < 0.0001). Mineral trioxide aggregate leaked significantly less than other materials tested with or without blood contamination of the root end cavities.

  9. Retentive force and magnetic flux leakage of magnetic attachment in various keeper and magnetic assembly combinations.

    PubMed

    Hasegawa, Mikage; Umekawa, Yoshitada; Nagai, Eiich; Ishigami, Tomohiko

    2011-04-01

    Magnetic attachments are commonly used for overdentures. However, it can be difficult to identify and provide the same type and size of magnetic assembly and keeper if a repair becomes necessary. Therefore, the size and type may not match. This study evaluated the retentive force and magnetic flux strength and leakage of magnetic attachments in different combinations of keepers and magnetic assemblies. For 6 magnet-keeper combinations using 4 sizes of magnets (GIGAUSS D400, D600, D800, and D1000) (n=5), retentive force was measured 5 times at a crosshead speed of 5 mm/min in a universal testing machine. Magnetic flux strength was measured using a Hall Effect Gaussmeter. Data were statistically analyzed using a 1-way ANOVA, and between-group differences were analyzed with Tukey's HSD post hoc test (α=.05). The mean retentive force of the same-size magnet-keeper combinations was 3.2 N for GIGAUSS D400 and 5.1 N for GIGAUSS D600, but was significantly reduced when using larger magnets (P<.05). Magnetic flux leakage was significantly lower for corresponding size combinations. Size differences influence the retentive force and magnetic flux strength of magnetic attachments. Retentive force decreased due to the closed field structure becoming incomplete and due to magnetic field leakage. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Heterogeneity-enhanced gas phase formation in shallow aquifers during leakage of CO2-saturated water from geologic sequestration sites

    NASA Astrophysics Data System (ADS)

    Plampin, Michael R.; Lassen, Rune N.; Sakaki, Toshihiro; Porter, Mark L.; Pawar, Rajesh J.; Jensen, Karsten H.; Illangasekare, Tissa H.

    2014-12-01

    A primary concern for geologic carbon storage is the potential for leakage of stored carbon dioxide (CO2) into the shallow subsurface where it could degrade the quality of groundwater and surface water. In order to predict and mitigate the potentially negative impacts of CO2 leakage, it is important to understand the physical processes that CO2 will undergo as it moves through naturally heterogeneous porous media formations. Previous studies have shown that heterogeneity can enhance the evolution of gas phase CO2 in some cases, but the conditions under which this occurs have not yet been quantitatively defined, nor tested through laboratory experiments. This study quantitatively investigates the effects of geologic heterogeneity on the process of gas phase CO2 evolution in shallow aquifers through an extensive set of experiments conducted in a column that was packed with layers of various test sands. Soil moisture sensors were utilized to observe the formation of gas phase near the porous media interfaces. Results indicate that the conditions under which heterogeneity controls gas phase evolution can be successfully predicted through analysis of simple parameters, including the dissolved CO2 concentration in the flowing water, the distance between the heterogeneity and the leakage location, and some fundamental properties of the porous media. Results also show that interfaces where a less permeable material overlies a more permeable material affect gas phase evolution more significantly than interfaces with the opposite layering.

  11. ANOVA Analysis of Student Daily Test Scores in Multi-Day Test Periods

    ERIC Educational Resources Information Center

    Mouritsen, Matthew L.; Davis, Jefferson T.; Jones, Steven C.

    2016-01-01

    Instructors are often concerned when giving multiple-day tests because students taking the test later in the exam period may have an advantage over students taking the test early in the exam period due to information leakage. However, exam scores seemed to decline as students took the same test later in a multi-day exam period (Mouritsen and…

  12. Experimental flow studies in glaucoma drainage device development.

    PubMed

    2001-10-01

    (I) To examine whether small holes produced by 248 nm excimer laser ablation in a polymer substrate could consistently produce a pressure drop in the desired target range (5-15 mm Hg) at physiological aqueous flow rates for use as an internal flow restrictor in a glaucoma drainage device, and (ii) to investigate whether external leakage could be reduced in comparison with conventional tube and plate glaucoma drainage devices by redesigning the exterior cross sectional shape of the portion contained within the sclerocorneal tunnel. Single holes with target diameters of 10 microm, 15 microm, 20 microm, and 25 microm were drilled using a 248 nm excimer laser in sample discs (n=6 at each diameter) punched from a 75 microm thick polyimide sheet. Sample discs were tested in a flow rig designed to measure the pressure drop across the discs. Using filtered, degassed water at a flow rate of 1.4 microl/min repeated flow measurements were taken (n=6) for each disc. After flow testing, all discs were imaged using a scanning electron microscope and the dimensions of each hole were derived using image analysis software. In the external leakage study, corneoscleral buttons (n=13) were prepared from cadaver pig eyes and mounted on an artificial anterior chamber infused with Tyrode solution. After the pressure had stabilised, standard occluded silicone tube implants were inserted through 23 gauge needle stab incisions at the limbus. These were compared against prototype PMMA implants with a novel shape profile inserted through 1.15 mm width microvitreoretinal (MVR) stab incisions at the limbus. The infusion rate was maintained and a second pressure measurement was taken when the pressure had stabilised. The difference between the first and second pressure measurement was then compared, as an index of external leakage. Ablated tubes were found to have a near perfect circular outline on both the entry and exit side. The observed pressure drops across the ablated sample discs at each target diameter were as follows: 10 microm, mean 25.66 (SD 4.9) mm Hg; 15 microm, 6.7 (1.15); 20 microm, 1.66 (1.07); and 25 microm, <0.1 mm Hg. A strong correlation was observed between observed pressure drops and those predicted by Poiseuille's formula (R(2) =0.996). Target ablations of 15 microm diameter produced tubes that consistently achieved a pressure drop within the desired range (5-15 mm Hg). In the external leakage study, preinsertion pressures (mm Hg; mean (SD)) were 19.00 (4.3) (conventional method) and 20.00 (3.9) (new technique with PMMA prototypes). Post-insertion pressures were significantly reduced (10.40 (7.7); p<0.01) for the conventional technique and were essentially unchanged for the new technique (18.80 (4.9); p>0.1). It was shown that it is possible, in principle, to control the dimensions of a manufactured tubular lumen in a glaucoma drainage device accurately enough to provide consistent protection from hypotony in the early period after glaucoma filtration surgery. By redesigning the external profile of glaucoma drainage device and incision technique, it was also shown that it is possible to eliminate uncontrolled external leakage.

  13. Acamprosate {monocalcium bis(3-acetamidopropane-1-sulfonate)} reduces ethanol-drinking behavior in rats and glutamate-induced toxicity in ethanol-exposed primary rat cortical neuronal cultures.

    PubMed

    Oka, Michiko; Hirouchi, Masaaki; Tamura, Masaru; Sugahara, Seishi; Oyama, Tatsuya

    2013-10-15

    Acamprosate, the calcium salt of bis(3-acetamidopropane-1-sulfonate), contributes to the maintenance of abstinence in alcohol-dependent patients, but its mechanism of action in the central nervous system is unclear. Here, we report the effect of acamprosate on ethanol-drinking behavior in standard laboratory Wistar rats, including voluntary ethanol consumption and the ethanol-deprivation effect. After forced ethanol consumption arranged by the provision of only one drinking bottle containing 10% ethanol, the rats were given a choice between two drinking bottles, one containing water and the other containing 10% ethanol. In rats selected for high ethanol preference, repeated oral administration of acamprosate diminished voluntary ethanol drinking. After three months of continuous access to two bottles, rats were deprived of ethanol for three days and then presented with two bottles again. After ethanol deprivation, ethanol preference was increased, and the increase was largely abolished by acamprosate. After exposure of primary neuronal cultures of rat cerebral cortex to ethanol for four days, neurotoxicity, as measured by the extracellular leakage of lactate dehydrogenase (LDH), was induced by incubation with glutamate for 1h followed by incubation in the absence of ethanol for 24h. The N-methyl-D-aspartate receptor blocker 5-methyl-10,11-dihydro-5H-dibenzo[a,d]-cyclohepten-5,10-imine, the metabotropic glutamate receptor subtype 5 antagonist 6-methyl-2-(phenylethynyl)pyridine and the voltage-gated calcium-channel blocker nifedipine all inhibited glutamate-induced LDH leakage from ethanol-exposed neurons. Acamprosate inhibited the glutamate-induced LDH leakage from ethanol-exposed neurons more strongly than that from intact neurons. In conclusion, acamprosate showed effective reduction of drinking behavior in rats and protected ethanol-exposed neurons by multiple blocking of glutamate signaling. © 2013 Elsevier B.V. All rights reserved.

  14. Flip-chip bonded optoelectronic integration based on ultrathin silicon (UTSi) CMOS

    NASA Astrophysics Data System (ADS)

    Hong, Sunkwang; Ho, Tawei; Zhang, Liping; Sawchuk, Alexander A.

    2003-06-01

    We describe the design and test of flip-chip bonded optoelectronic CMOS devices based on Peregrine Semiconductor's 0.5 micron Ultra-Thin Silicon on sapphire (UTSi) technology. The UTSi process eliminates the substrate leakage that typically results in crosstalk and reduces parasitic capacitance to the substrate, providing many benefits compared to bulk silicon CMOS. The low-loss synthetic sapphire substrate is optically transparent and has a coefficient of thermal expansion suitable for flip-chip bonding of vertical cavity surface emitting lasers (VCSELs) and detectors. We have designed two different UTSi CMOS chips. One contains a flip-chip bonded 1 x 4 photodiode array, a receiver array, a double edge triggered D-flip flop-based 2047-pattern pseudo random bit stream (PRBS) generator and a quadrature-phase LC-voltage controlled oscillator (VCO). The other chip contains a flip-chip bonded 1 x 4 VCSEL array, a driver array based on high-speed low-voltage differential signals (LVDS) and a full-balanced differential LC-VCO. Each VCSEL driver and receiver has individual input and bias voltage adjustments. Each UTSi chip is mounted on different printed circuit boards (PCBs) which have holes with about 1 mm radius for optical output and input paths through the sapphire substrate. We discuss preliminary testing of these chips.

  15. Solution of AntiSeepage for Mengxi River Based on Numerical Simulation of Unsaturated Seepage

    PubMed Central

    Ji, Youjun; Zhang, Linzhi; Yue, Jiannan

    2014-01-01

    Lessening the leakage of surface water can reduce the waste of water resources and ground water pollution. To solve the problem that Mengxi River could not store water enduringly, geology investigation, theoretical analysis, experiment research, and numerical simulation analysis were carried out. Firstly, the seepage mathematical model was established based on unsaturated seepage theory; secondly, the experimental equipment for testing hydraulic conductivity of unsaturated soil was developed to obtain the curve of two-phase flow. The numerical simulation of leakage in natural conditions proves the previous inference and leakage mechanism of river. At last, the seepage control capacities of different impervious materials were compared by numerical simulations. According to the engineering actuality, the impervious material was selected. The impervious measure in this paper has been proved to be effectible by hydrogeological research today. PMID:24707199

  16. Recent glacial events in the Norwegian North Sea - implications towards a better understanding of charging/leakage of oil fields and its impact oil exploration

    NASA Astrophysics Data System (ADS)

    Stoddart, Daniel

    2014-05-01

    Recent drilling and appraisal on the Southern Utsira High, Norwegian North Sea, has proved several large oil/gas discoveries, including the giant Johan Sverdrup, Edvard Grieg, Draupne, Ragnarrock and Apollo oil fields, making this a prolific petroleum area. The Southern Utsira High contains a variety of hydrocarbon density fluids found at several stratigraphic levels illustrating the compartmentalized nature of accumulations and charge history. The Southern Utsira High has been in a position to receive an oil/gas charge for a considerable period of time, with the basin towards the west most likely generating petroleum from early Eocene (50M Mabp) to its maximum present day burial depth. However, reservoir temperatures on the Southern Utsira High are just above the threshold for biodegradation (80°C). The Southern Utsira High oils are non-biodegraded suggesting that the majority of the oil charged relatively late - ca.3 million years ago to present day. The effects of the glaciation on the filling history of the Southern Utsira High are currently being assessed. It is clear that several erosional surfaces in the Pliocene can be identified, as well as glacial channels and moraine deposits, indicating that significant deposition and erosion occurred in the last five million years. Importantly, the effects of glacial rebound mean that the Southern Utsira High more than likely underwent tilting and possible leakage, not just once, but several times in the last 1 million years. The effects of tilting/leakage of geological areas on oil migration have been recognized by several authors. However, the detailed integration of geological mapping and geochemical evidence has not previously been published. The implications of a detailed assessment of tilting of a ''high' through time are; 1) opening up areas where oil migration is thought to be high risk or impossible; 2) identify possible paleo-oil columns aiding the de-risking of discovery appraisal strategies. The evidence of tilting/leakage of oil accumulations through time can be recognized in several oil fields on the Utsira High. The giant Johan Sverdrup discovery oil columns contain paleo-OWC, residual oil zones/paleo-oil columns, and oil shows considerably deeper than the current OWC or residual oil columns. Lundin has performed detailed mapping of the seabed and water column in the Alvheim/Utsira High areas in order to identify areas of gas leakage and its geological manifestations on the seabed and ultimately resulting in the collection of high quality samples. Results shows that gas leakage is prominent over the Alvheim and Utsira High areas and the implications of this to oil exploration will be discussed. In summary, Lundin's approach to oil migration is to better understand the fluid/gas movement throughout the whole basin through time. The talk will focus on the role of glaciations on the timing of charge from the South Viking Graben, fill-spill directions on the Southern Utsira High, the effects of late tilting/leakage on the charge/re-distribution of oil, and seabed / water column characterization and sampling. All placed in the context of oil exploration.

  17. Use of soil moisture probes to estimate ground water recharge at an oil spill site

    USGS Publications Warehouse

    Delin, G.N.; Herkelrath, W.N.

    2005-01-01

    Soil moisture data collected using an automated data logging system were used to estimate ground water recharge at a crude oil spill research site near Bemidji, Minnesota. Three different soil moisture probes were tested in the laboratory as well as the field conditions of limited power supply and extreme weather typical of northern Minnesota: a self-contained reflectometer probe, and two time domain reflectometry (TDR) probes, 30 and 50 cm long. Recharge was estimated using an unsaturated zone water balance method. Recharge estimates for 1999 using the laboratory calibrations were 13 to 30 percent greater than estimates based on the factory calibrations. Recharge indicated by the self-contained probes was 170 percent to 210 percent greater than the estimates for the TDR probes regardless of calibration method. Results indicate that the anomalously large recharge estimates for the self-contained probes are not the result of inaccurate measurements of volumetric moisture content, but result from the presence of crude oil, or bore-hole leakage. Of the probes tested, the 50 cm long TDR probe yielded recharge estimates that compared most favorably to estimates based on a method utilizing water table fluctuations. Recharge rates for this probe represented 24 to 27 percent of 1999 precipitation. Recharge based on the 30 cm long horizontal TDR probes was 29 to 37 percent of 1999 precipitation. By comparison, recharge based on the water table fluctuation method represented about 29 percent of precipitation. (JAWRA) (Copyright ?? 2005).

  18. Optimal power and efficiency of quantum Stirling heat engines

    NASA Astrophysics Data System (ADS)

    Yin, Yong; Chen, Lingen; Wu, Feng

    2017-01-01

    A quantum Stirling heat engine model is established in this paper in which imperfect regeneration and heat leakage are considered. A single particle which contained in a one-dimensional infinite potential well is studied, and the system consists of countless replicas. Each particle is confined in its own potential well, whose occupation probabilities can be expressed by the thermal equilibrium Gibbs distributions. Based on the Schrödinger equation, the expressions of power output and efficiency for the engine are obtained. Effects of imperfect regeneration and heat leakage on the optimal performance are discussed. The optimal performance region and the optimal values of important parameters of the engine cycle are obtained. The results obtained can provide some guidelines for the design of a quantum Stirling heat engine.

  19. Brayton heat exchanger unit development program (alternate design)

    NASA Technical Reports Server (NTRS)

    Duncan, J. D.; Gibson, J. C.; Graves, R. F.; Morse, C. J.; Richard, C. E.

    1973-01-01

    A Brayton Heat Exchanger Unit Alternate Design (BHXU-Alternate) consisting of a recuperator, a heat sink heat exchanger, and a gas ducting system, was designed and fabricated. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. Emphasis was on double containment against external leakage and leakage of the organic coolant into the gas stream. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement, including the close-coupled integration of the BHXU-Alternate with the Brayton Rotating Unit (BRU).

  20. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    PubMed

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

Top