DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This is the RCRA required permit application for Radioactive and Hazardous Waste Management at the Oak Ridge Y-12 Plant for the following units: Building 9206 Container Storage Unit; Building 9212 Container Storage Unit; Building 9720-12 Container Storage Unit; Cyanide Treatment Unit. All four of these units are associated with the recovery of enriched uranium and other metals from wastes generated during the processing of nuclear materials.
Storage of platelets: effects associated with high platelet content in platelet storage containers.
Gulliksson, Hans; Sandgren, Per; Sjödin, Agneta; Hultenby, Kjell
2012-04-01
A major problem associated with platelet storage containers is that some platelet units show a dramatic fall in pH, especially above certain platelet contents. The aim of this study was a detailed investigation of the different in vitro effects occurring when the maximum storage capacity of a platelet container is exceeded as compared to normal storage. Buffy coats were combined in large-volume containers to create primary pools to be split into two equal aliquots for the preparation of platelets (450-520×10(9) platelets/unit) in SSP+ for 7-day storage in two containers (test and reference) with different platelet storage capacity (n=8). Exceeding the maximum storage capacity of the test platelet storage container resulted in immediate negative effects on platelet metabolism and energy supply, but also delayed effects on platelet function, activation and disintegration. Our study gives a very clear indication of the effects in different phases associated with exceeding the maximum storage capacity of platelet containers but throw little additional light on the mechanism initiating those negative effects. The problem appears to be complex and further studies in different media using different storage containers will be needed to understand the mechanisms involved.
Craddock, William H.; Drake II, Ronald M.; Mars, John L.; Merrill, Matthew D.; Warwick, Peter D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Cahan, Steven A.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2012-01-01
This report presents ten storage assessment units (SAUs) within the Powder River Basin of Wyoming, Montana, South Dakota, and Nebraska. The Powder River Basin contains a thick succession of sedimentary rocks that accumulated steadily throughout much of the Phanerozoic, and at least three stratigraphic packages contain strata that are suitable for CO2 storage. Pennsylvanian through Triassic siliciclastic strata contain two potential storage units: the Pennsylvanian and Permian Tensleep Sandstone and Minnelusa Formation, and the Triassic Crow Mountain Sandstone. Jurassic siliciclastic strata contain one potential storage unit: the lower part of the Sundance Formation. Cretaceous siliciclastic strata contain seven potential storage units: (1) the Fall River and Lakota Formations, (2) the Muddy Sandstone, (3) the Frontier Sandstone and Turner Sandy Member of the Carlile Shale, (4) the Sussex and Shannon Sandstone Members of Cody Shale, and (5) the Parkman, (6) Teapot, and (7) Teckla Sandstone Members of the Mesaverde Formation. For each SAU, we discuss the areal distribution of suitable CO2 reservoir rock. We also characterize the overlying sealing unit and describe the geologic characteristics that influence the potential CO2 storage volume and reservoir performance. These characteristics include reservoir depth, gross thickness, net thickness, porosity, permeability, and groundwater salinity. Case-by-case strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are presented. Although assessment results are not contained in this report, the geologic information included herein will be employed to calculate the potential storage space in the various SAUs.
Associate Directorate Environmental Management Infrastructure Plan for Area G and Area L Domes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Patrice Ann; Baumer, Andrew Ronald
Technical Area 54, at Los Alamos National Laboratory (LANL) is situated in the east-central portion of the Laboratory on the Mesita del Buey between Pajarito Canyon to the south and Cañada del Buey to the north. TA-54 includes four MDAs designated as G, H, J, and L; a waste characterization, container storage, and transfer facility; active TRU waste and MLLW waste storage and low-level waste (LLW) disposal operations at Area G; active hazardous and mixed low-level (MLLW) waste storage operations at Area L; and administrative and support areas. MDA J has previously under-gone closure. Area G is a waste managementmore » and disposal area, used for the disposal and storage of radioactive wastes since 1957. Since August 2015, Area G has been in warm standby and provides minimal operations to support safety, compliance, and nitrate salt remediation. Located within Area G, MDA G covers 63-acres. MDA G contains 334 active and inactive waste management units, which include 36 pits, 294 shafts, and 4 trenches. In 1971, Area G began use for the retrievable storage of TRU waste. There are two pits, four trenches and 60 shafts that contain retrievable TRU waste. Thirty-three of the shafts contain TRU waste that may present unique problems for retrieval. In 1986, segregation of MLLW was initiated at Area G for treatment and temporary storage or for off-site disposal. Area G is the only active LLW disposal facility at the Laboratory. Current operations at Area G include storage and characterization of TRU and mixed TRU waste destined for off-site disposal at the Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico and the storage of MLLW destined for off-site treatment and/or disposal. Several above-ground container storage units (CSUs) are currently used for storage of containerized MLLW and/or mixed TRU wastes. These consist of asphalt pads and associated fabric domes or other structures. As defined by the Consent Order, MDA G contains 229 of the 334 subsurface waste management units at Area G. These MDA G disposal units include 32 pits, 193 shafts, and 4 trenches and contain LLW, MLLW and TRU waste. The remaining 105 solid waste management units (SWMUs) include RCRA-regulated landfill and storage units and DOE-regulated LLW disposal units. The TA-54 closure project must ensure that continuing waste operations at Area G and their transition to an interim or enduring facility are coordinated with closure activities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-05-01
In compliance with the Resource Conservation and Recovery Act (RCRA), this report discusses information relating to permit applications for three tank storage units at Y-12. The storage units are: Building 9811-1 RCRA Tank Storage Unit (OD-7); Waste Oil/Solvent Storage Unit (OD-9); and Liquid Organic Solvent Storage Unit (OD-10). Numerous sections discuss the following: Facility description; waste characteristics; process information; groundwater monitoring; procedures to prevent hazards; contingency plan; personnel training; closure plan, post closure plan, and financial requirements; record keeping; other federal laws; organic air emissions; solid waste management units; and certification. Sixteen appendices contain such items as maps, waste analysesmore » and forms, inspection logs, equipment identification, etc.« less
Shuttle Kit Freezer Refrigeration Unit Conceptual Design
NASA Technical Reports Server (NTRS)
Copeland, R. J.
1975-01-01
The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.
Sandgren, P; Hild, M; Sjödin, A; Gulliksson, H
2010-11-01
The novel TACSI system is designed for automated preparation of platelets (PLTs) from pooled buffy coats (BCs). One TACSI device will handle 6 units at the same time. The aim of our in vitro study is to investigate the effects of using this automated equipment with subsequent storage in two different plastic containers and to compare these results with PLTs prepared by the OrbiSac system. Buffy-coat-derived PLTs (n=8) were prepared by using the TACSI system, including storage in polyvinyl chloride (PVC)-based plastic containers with di, n-decyl phthalate (DnDP) (TACSI R) and BTHC (TACSI T)-based plasticizers. As a reference, the OrbiSac System was used to prepare PLTs (n=8) with subsequent storage in a PVC plastic container with a citrate-based plasticizer (BTHC). In total, 16 TACSI and eight reference units, supplied by approximately 30% plasma and 70% SSP+, were analysed for various in vitro variables during the 7-day storage period. No significant difference in PLT counts, LDH, mean platelet volume (MPV) and adenosine triphosphate between the groups was detected. Glucose was lower (P<0·05) and lactate was higher (P<0·05) in TACSI R vs. OrbiSac. With exception of day 7 (P<0·05 TACSI R vs. OrbiSac), HSR reactivity were not different between groups. Extent of shape change was lower and CD62P higher in TACSI T when compared with TACSI R and OrbiSac units (P<0·05). pH was maintained at >6·8 (day 7) and swirling remained at the highest level (score=2) for all units throughout storage. Platelets prepared by the TACSI system with subsequent storage in two different PVC-based plastic containers were equivalent to reference PLTs with regard to in vitro characteristics during 7 days of storage. © 2010 The Author(s). Vox Sanguinis © 2010 International Society of Blood Transfusion.
Low temperature storage container for transporting perishables to space station
NASA Technical Reports Server (NTRS)
Dean, William G (Inventor); Owen, James W. (Inventor)
1988-01-01
This invention is directed to the long term storage of frozen and refrigerated food and biological samples by the space shuttle to the space station. A storage container is utilized which has a passive system so that fluid/thermal and electrical interfaces with the logistics module is not required. The container for storage comprises two units, each having an inner storage shell and an outer shell receiving the inner shell and spaced about it. The novelty appears to lie in the integration of thermally efficient cryogenic storage techniques with phase change materials, including the multilayer metalized surface thin plastic film insulation and the vacuum between the shells. Additionally the fiberglass constructed shells having fiberglass honeycomb portions, and the lining of the space between the shells with foil combine to form a storage container which may keep food and biological samples at very low temperatures for very long periods of time utilizing a passive system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Programs
2010-06-17
The Area 5 Hazardous Waste Storage Unit (HWSU) was established to support testing, research, and remediation activities at the Nevada Test Site (NTS), a large-quantity generator of hazardous waste. The HWSU, located adjacent to the Area 5 Radioactive Waste Management Site (RWMS), is a prefabricated, rigid steel-framed, roofed shelter used to store hazardous nonradioactive waste generated on the NTS. No offsite generated wastes are managed at the HWSU. Waste managed at the HWSU includes the following categories: Flammables/Combustibles; Acid Corrosives; Alkali Corrosives; Oxidizers/Reactives; Toxics/Poisons; and Other Regulated Materials (ORMs). A list of the regulated waste codes accepted for storage atmore » the HWSU is provided in Section B.2. Hazardous wastes stored at the HWSU are stored in U.S. Department of Transportation (DOT) compliant containers, compatible with the stored waste. Waste transfer (between containers) is not allowed at the HWSU and containers remain closed at all times. Containers are stored on secondary containment pallets and the unit is inspected monthly. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational Resource Conservation and Recovery Act (RCRA) units at the NTS and their respective regulatory status.« less
40 CFR 63.8985 - Am I subject to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... production facility includes all HCl storage tanks that contain liquid HCl product that is produced in the... service used to transfer liquid HCl product from the HCl production unit to the HCl storage tanks and/or... site via pipeline. (2) Storage tanks that are dedicated feedstock tanks for another process and storage...
Skripchenko, Andrey; Myrup, Andrew; Thompson-Montgomery, Dedeene; Awatefe, Helen; Wagner, Stephen J
2013-04-01
Platelet (PLT) aliquots for pediatric use have been shown to retain in vitro properties when stored in gas-impermeable syringes for up to 6 hours. As an alternative, PLT aliquots can be stored for longer periods in containers used for storage of whole blood-derived PLTs. These containers are not available separate from whole blood collection sets and PLT volumes less than 35 mL either have not been evaluated or may be unsuitable for PLT storage. Gas-permeable fluoroethylene propylene (FEP) containers have been used in the storage of cell therapy preparations and are available in multiple sizes as single containers but have not been evaluated for PLT storage. A single apheresis unit was divided on Day 3 into small aliquots with volume ranging from 20 to 60 mL, transferred using a sterile connection device, and stored for an additional 2 days either in CLX (control) or in FEP containers. PLT storage properties of PLTs stored in FEP containers were compared to those stored in CLX containers. Standard PLT in vitro assays were performed (n =6). PLT storage properties were either similar to those of CLX containers or differed by less than 20% excepting carbon dioxide levels, which varied less than 60%. Pediatric PLT aliquots of 20, 30, and 60mL transferred on Day 3 into FEP cell culture containers adequately maintain PLT properties for an additional 2days of storage. © 2012 American Association of Blood Banks.
Toroidal constant-tension superconducting magnetic energy storage units
Herring, J. Stephen
1992-01-01
A superconducting magnetic energy storage unit is provided in which the magnet is wound in a toroidal fashion such that the magnetic field produced is contained only within the bore of the magnet, and thus producing a very low external field. The superconducting magnet includes a coolant channel disposed through the wire. The bore of the magnet comprises a storage volume in which cryogenic coolant is stored, and this volume supplies the coolant to be delivered to the coolant channel in the magnet.
Toroidal constant-tension superconducting magnetic energy storage units
Herring, J.S.
1992-11-03
A superconducting magnetic energy storage unit is provided in which the magnet is wound in a toroidal fashion such that the magnetic field produced is contained only within the bore of the magnet, and thus producing a very low external field. The superconducting magnet includes a coolant channel disposed through the wire. The bore of the magnet comprises a storage volume in which cryogenic coolant is stored, and this volume supplies the coolant to be delivered to the coolant channel in the magnet. 6 figs.
33 CFR 105.265 - Security measures for handling cargo.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., containers, or other cargo transport units entering the facility match the delivery note or equivalent cargo..., containers or other cargo transport units, and cargo storage areas within the facility for evidence of... cargo. 105.265 Section 105.265 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...
33 CFR 105.265 - Security measures for handling cargo.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., containers, or other cargo transport units entering the facility match the delivery note or equivalent cargo..., containers or other cargo transport units, and cargo storage areas within the facility for evidence of... cargo. 105.265 Section 105.265 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...
33 CFR 105.265 - Security measures for handling cargo.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., containers, or other cargo transport units entering the facility match the delivery note or equivalent cargo..., containers or other cargo transport units, and cargo storage areas within the facility for evidence of... cargo. 105.265 Section 105.265 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...
33 CFR 105.265 - Security measures for handling cargo.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., containers, or other cargo transport units entering the facility match the delivery note or equivalent cargo..., containers or other cargo transport units, and cargo storage areas within the facility for evidence of... cargo. 105.265 Section 105.265 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...
33 CFR 105.265 - Security measures for handling cargo.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., containers, or other cargo transport units entering the facility match the delivery note or equivalent cargo..., containers or other cargo transport units, and cargo storage areas within the facility for evidence of... cargo. 105.265 Section 105.265 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...
ERIC Educational Resources Information Center
Welch, Mary A., Ed.
1991-01-01
The analysis of public goods is presented with a discussion of the rules for fertilizer and pesticide storage units in Indiana. A basic rule summary is presented with descriptions of the types of dikes that might be considered for containment. Estimated costs are projected along with the number of contained liquid fertilizer spills by size in…
Improved solar heating systems
Schreyer, J.M.; Dorsey, G.F.
1980-05-16
An improved solar heating system is described in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75 to 180/sup 0/F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing ad releasing heat for distribution.
Schreyer, James M.; Dorsey, George F.
1982-01-01
An improved solar heating system in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75.degree. to 180.degree. F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing and releasing heat for distribution.
Code of Federal Regulations, 2012 CFR
2012-01-01
...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...
Code of Federal Regulations, 2013 CFR
2013-01-01
...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...
Code of Federal Regulations, 2014 CFR
2014-01-01
...: (a) Individual means a citizen of the United States or an alien lawfully admitted for permanent residence; (b) Information means papers, records, photographs, magnetic storage media, micro storage media, and other documentary materials, regardless of physical form or characteristics, containing data about...
Brown, Philip M.; Brown, D.L.; Reid, M.S.; Lloyd, O.B.
1979-01-01
The report describes the subsurface distribution of rocks of Cretaceous to Late Jurassic( ) age in the Atlantic Coastal Plain , South Carolina, and Georgia, and examines their potential for deep-well waste storage into th part of the regional sediment mass which lies below the deepest zones containing usable ground waters. For the study, usable ground water is considered to be that which contains less than 10,000 mg/L dissolved solids. Using a group of geohydrologic parameters derived from or combining 21 categories of basic data, established from study and interpretation of well cuttings and geophysical logs, a series of 32 regional maps and 8 stratigraphic cross sections was constructed. For each of the eight geologic units delineated in the subsurface, the maps illustrate the distribution of waste-storage potential in terms of areal extent, depth below land surface, sand-shale geometry, and the approximate sodium chloride concentration of a unit 's nonusable ground water. In areas where the geologic units contain nonusable ground water, the depth below land surface and the thickness of potential waste-storage reservoir and reservoir-seal combinations are variable. The range in variability appears to be broad enough to meet the need for a wide choice among the geologic requirements that would normally be considered in selecting specific waste-storage sites for detailed examination. (Woodard-USGS)
Biochemistry of whole blood in poly(ethylene-co-ethylacrylate) experimental blood containers.
Horowitz, B; Rowe, A W; Stryker, M H; Van der Sande, J; Waldman, A A; Wong, S C; Gass, J D; Woods, K R
1985-01-01
The biochemical status of whole blood stored in containers fabricated of ethylene ethylacrylate (EEA) film was monitored at several times during 4 weeks of storage at 4 degrees C. Fifteen biochemical indicators were studied to reflect on erythrocyte integrity, cellular metabolism, plasma protein stability, and microaggregate formation. Comparison to storage in polyvinyl chloride (PVC) containers was made by distributing aliquots from each unit of blood among the containers being compared. Whole blood in EEA developed significantly higher levels of plasma hemoglobin, erythrocyte osmotic fragility, and D-glycerate-2,3-diphosphate (2,3-DPG), and somewhat greater glucose utilization, lactate production, and pH. These biochemical differences were not of great magnitude and the data suggest that EEA containers are compatible with the storage of whole blood.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
... a central gas/liquids separation and storage facility (Ryckman Plant) where all of the pipelines meet, containing oil, water and gas handling, and natural gas liquids (NGL) storage equipment; and it... as the Ryckman Creek (Nugget Unit), into a new interstate natural gas storage field. The Project is...
EVALUATION OF VOLUMETRIC LEAK DETECTION METHODS USED IN UNDERGROUND STORAGE TANKS
In the spring and summer of 1987, the United States Environmental Protection Agency (EPA) evaluated the performance of 25 commercially available volumetric test methods for the detection of small leaks in underground storage tanks containing gasoline. Performance was estimated by...
Hanford facility dangerous waste permit application, general information portion. Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonnichsen, J.C.
1997-08-21
For purposes of the Hanford facility dangerous waste permit application, the US Department of Energy`s contractors are identified as ``co-operators`` and sign in that capacity (refer to Condition I.A.2. of the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit). Any identification of these contractors as an ``operator`` elsewhere in the application is not meant to conflict with the contractors` designation as co-operators but rather is based on the contractors` contractual status with the U.S. Department of Energy, Richland Operations Office. The Dangerous Waste Portion of the initial Hanford Facility Resource Conservation and Recovery Act Permit,more » which incorporated five treatment, storage, and/or disposal units, was based on information submitted in the Hanford Facility Dangerous Waste Permit Application and in closure plan and closure/postclosure plan documentation. During 1995, the Dangerous Waste Portion was modified twice to incorporate another eight treatment, storage, and/or disposal units; during 1996, the Dangerous Waste Portion was modified once to incorporate another five treatment, storage, and/or disposal units. The permit modification process will be used at least annually to incorporate additional treatment, storage, and/or disposal units as permitting documentation for these units is finalized. The units to be included in annual modifications are specified in a schedule contained in the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit. Treatment, storage, and/or disposal units will remain in interim status until incorporated into the Permit. The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to individual operating treatment, storage, and/or disposal units for which Part B permit application documentation has been, or is anticipated to be, submitted. Documentation for treatment, storage, and/or disposal units undergoing closure, or for units that are, or are anticipated to be, dispositioned through other options, will continue to be submitted by the Permittees in accordance with the provisions of the Hanford Federal Facility Agreement and Consent Order. However, the scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the contents of the Part B permit application guidance documentation prepared by the Washington State Department of Ecology and the U.S. Environmental Protection Agency, with additional information needs defined by revisions of Washington Administrative Code 173-303 and by the Hazardous and Solid Waste Amendments. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (i.e., either operating units, units undergoing closure, or units being dispositioned through other options).« less
Wagner, Stephen J; Myrup, Andrew; Awatefe, Helen; Thompson-Montgomery, Dedeene; Hirayama, Junichi; Skripchenko, Andrey
2008-12-01
Extensive periods without agitation can occasionally occur during platelet (PLT) shipment and can affect PLT quality during 5- to 7-day storage. The use of buffer-containing PLT additive solutions (ASs) may better preserve PLT quality during storage by maintaining PLT pH and other in vitro variables. A newly described bicarbonate-containing AS, M-sol, was compared to plasma for preservation of whole blood-derived PLT concentrates in which a 30-hour interruption of agitation was included. ABO-identical PLT-rich plasma intermediate products were pooled in sets of four, split, and centrifuged with subsequent plasma expression (n = 12). Two units were resuspended with M-sol AS to produce a 70 percent solution/30 percent plasma PLT concentrate; 2 units were resuspended in 100 percent plasma. One M-sol resuspended unit and 1 plasma unit were held on a laboratory bench in a standard shipping box for 30 hours between Day 2 and Day 3, while the other M-sol and plasma unit were continuously agitated. Standard in vitro testing for PLT quality variables on each set of 4 units was performed during storage (n = 12). Interrupting agitation of PLTs suspended in M-sol resulted in less of a pH decrement during storage than that of PLTs suspended in 100 percent plasma. On Days 5 and 7, the pH differences between M-sol and plasma units were 0.56 and 0.75 pH units, respectively (p < 0.0003). In addition, PLTs suspended in M-sol and subjected to an interruption of agitation had lesser Day 7 CD62+ cells, glucose utilization, and lactate production and greater hypotonic stress response, morphology, swirling, and aggregation response than those suspended in plasma (p = 0.005). The in vitro properties of PLTs suspended in 70 percent M-sol/30 percent plasma and subjected to a 30-hour interruption of agitation are better maintained during 7-day storage than those of matched units suspended in plasma.
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa.
Mellor, Jonathan E; Smith, James A; Samie, Amidou; Dillingham, Rebecca A
2013-09-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household ( n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm 2 ; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μ max , of 0.072 ± 0.003 h -1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth.
Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa
Mellor, Jonathan E.; Samie, Amidou; Dillingham, Rebecca A.
2014-01-01
Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household (n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm2; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μmax, of 0.072 ± 0.003 h−1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth. PMID:25190902
40 CFR 264.553 - Temporary Units (TU).
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Temporary Units (TU). 264.553 Section 264.553 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... Provisions for Cleanup § 264.553 Temporary Units (TU). (a) For temporary tanks and container storage areas...
40 CFR 264.553 - Temporary Units (TU).
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Temporary Units (TU). 264.553 Section 264.553 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... Provisions for Cleanup § 264.553 Temporary Units (TU). (a) For temporary tanks and container storage areas...
29 CFR 1910.110 - Storage and handling of liquefied petroleum gases.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (i) Containers used with systems embodied in paragraphs (d), (e), (g), and (h) of this section... unit of weight for containers with a water capacity of 300 pounds or less. (h) With marking indicating... Table H-23. Table H-23 Water capacity per container Minimum distances Containers Underground Aboveground...
29 CFR 1910.110 - Storage and handling of liquefied petroleum gases.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (i) Containers used with systems embodied in paragraphs (d), (e), (g), and (h) of this section... unit of weight for containers with a water capacity of 300 pounds or less. (h) With marking indicating... Table H-23. Table H-23 Water capacity per container Minimum distances Containers Underground Aboveground...
DOE Office of Scientific and Technical Information (OSTI.GOV)
HOPKINS, A.M.
2007-02-20
The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the ''Resource Conservation and Recovery Act of 1976'' (RCRA) and Washington State ''Hazardous Waste Management Act, RCW 70.105'', have been deactivated and are being actively decommissioned. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4, D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building.more » The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground mining from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the ''Hanford Facility Dangerous Waste Closure Plant, 241-Z Treatment and Storage Tanks''.« less
Schäfer, Judith; Stanojlovic, Luisa; Trierweiler, Bernhard; Bunzel, Mirko
2017-03-01
Storage related changes in the cell wall composition potentially affect the texture of plant-based foods and the physiological effects of cell wall based dietary fiber components. Therefore, a detailed characterization of cell wall polysaccharides and lignins from broccoli stems was performed. Freshly harvested broccoli and broccoli stored at 20°C and 1°C for different periods of time were analyzed. Effects on dietary fiber contents, polysaccharide composition, and on lignin contents/composition were much more pronounced during storage at 20°C than at 1°C. During storage, insoluble dietary fiber contents of broccoli stems increased up to 13%. Storage related polysaccharide modifications include an increase of the portions of cellulose, xylans, and homogalacturonans and a decrease of the neutral pectic side-chains arabinans and galactans. Broccoli stem lignins are generally rich in guaiacyl units. Lignins from freshly harvested broccoli stems contain slightly larger amounts of p-hydroxyphenyl units than syringyl units. Syringyl units are predominantly incorporated into the lignin polymers during storage, resulting in increased acetyl bromide soluble lignin contents. NMR-based analysis of the interunit linkage types of broccoli stem lignins revealed comparably large portions of resinol structures for a guaiacyl rich lignin. Incorporation of syringyl units into the polymers over storage predominantly occurs through β-O-4-linkages. Copyright © 2017 Elsevier Ltd. All rights reserved.
Roberts-Ashby, Tina L.; Brennan, Sean T.; Buursink, Marc L.; Covault, Jacob A.; Craddock, William H.; Drake II, Ronald M.; Merrill, Matthew D.; Slucher, Ernie R.; Warwick, Peter D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2014-01-01
This report presents 27 storage assessment units (SAUs) within the United States (U.S.) Gulf Coast. The U.S. Gulf Coast contains a regionally extensive, thick succession of clastics, carbonates, salts, and other evaporites that were deposited in a highly cyclic depositional environment that was subjected to a fluctuating siliciclastic sediment supply and transgressive and regressive sea levels. At least nine major depositional packages contain porous strata that are potentially suitable for geologic carbon dioxide (CO2) sequestration within the region. For each SAU identified within these packages, the areal distribution of porous rock that is suitable for geologic CO2 sequestration is discussed, along with a description of the geologic characteristics that influence the potential CO2 storage volume and reservoir performance. These characteristics include reservoir depth, gross thickness, net-porous thickness, porosity, permeability, and groundwater salinity. Additionally, a characterization of the overlying regional seal for each SAU is presented. On a case-by-case basis, strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are also presented. Geologic information presented in this report has been employed to calculate potential storage capacities for CO2 sequestration in the SAUs that are assessed herein, although complete assessment results are not contained in this report.
Applicability of Thermal Storage Systems to Air Force Facilities
1990-09-01
Analisis of Region 6 Upper Limit Retrofit Scenario 30% Reduction .... ............. 4.52 4.58 Economic Analysis of Region 7 Upper Limit Retrofit Scenario...or a dynamic-direct contact type. They usually include all the controls, chilling and storage equipment in one self-contained, skid mounted, factory ...SCS technology. One promising trend in reducing system construction costs is the factory -packaged thermal storage cooling unit. As of February 1989
Roberts-Ashby, Tina L.; Brennan, Sean T.; Merrill, Matthew D.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2015-08-26
This report presents five storage assessment units (SAUs) that have been identified as potentially suitable for geologic carbon dioxide sequestration within a 35,075-square-mile area that includes the entire onshore and State-water portions of the South Florida Basin. Platform-wide, thick successions of laterally extensive carbonates and evaporites deposited in highly cyclic depositional environments in the South Florida Basin provide several massive, porous carbonate reservoirs that are separated by evaporite seals. For each storage assessment unit identified within the basin, the areal distribution of the reservoir-seal couplet identified as suitable for geologic Carbon dioxide sequestration is presented, along with a description of the geologic characteristics that influence the potential carbon dioxide storage volume and reservoir performance. On a case-by-case basis, strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are also discussed. Geologic information presented in this report has been employed to calculate potential storage capacities for carbon dioxide sequestration in the storage assessment units assessed herein, although complete assessment results are not contained in this report.
Merrill, Matthew D.; Covault, Jacob A.; Craddock, William H.; Slucher, Ernie R.; Warwick, Peter D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Cahan, Steven M.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2012-01-01
The 2007 Energy Independence and Security Act (Public Law 110-140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used for the national CO2 assessment is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of twelve storage assessment units (SAUs) in six separate packages of sedimentary rock within the Hanna, Laramie, and Shirley Basins of Wyoming. It focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included herein will be employed, as specified in the methodology, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data in a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.
Covault, Jacob A.; Buursink, Mark L.; Craddock, William H.; Merrill, Matthew D.; Blondes, Madalyn S.; Gosai, Mayur A.; Freeman, P.A.; Warwick, Peter D.; Corum, Margo D.
2012-01-01
This report identifies and contains geologic descriptions of twelve storage assessment units (SAUs) in six separate packages of sedimentary rocks within the Bighorn Basin of Wyoming and Montana and focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included here will be employed, as specified in the methodology of earlier work, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Wells sharing the same well borehole are treated as a single penetration. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.
Rossner, Alan; Jordan, Carolyn E; Wake, Cameron; Soto-Garcia, Lydia
2017-10-01
The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure. This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations in homes allows for better designs for storage bins and ventilation for storage areas. Hence, uniform policies for stored wood pellets in homes, schools, and businesses can be framed to ensure occupant safety. Currently in New York State rebates for the installation of wood pellet boilers are only provided if the bulk pellet storage is outside of the home, yet states such as New Hampshire, Vermont, and Maine currently do not have these restrictions.
National assessment of geologic carbon dioxide storage resources: data
,
2013-01-01
In 2012, the U.S. Geological Survey (USGS) completed the national assessment of geologic carbon dioxide storage resources. Its data and results are reported in three publications: the assessment data publication (this report), the assessment results publication (U.S. Geological Survey Geologic Carbon Dioxide Storage Resources Assessment Team, 2013a, USGS Circular 1386), and the assessment summary publication (U.S. Geological Survey Geologic Carbon Dioxide Storage Resources Assessment Team, 2013b, USGS Fact Sheet 2013–3020). This data publication supports the results publication and contains (1) individual storage assessment unit (SAU) input data forms with all input parameters and details on the allocation of the SAU surface land area by State and general land-ownership category; (2) figures representing the distribution of all storage classes for each SAU; (3) a table containing most input data and assessment result values for each SAU; and (4) a pairwise correlation matrix specifying geological and methodological dependencies between SAUs that are needed for aggregation of results.
Corrective Action Management Unit Report of Post-Closure Care Activities Calendar Year 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziock, Robert; Little, Bonnie Colleen
The Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consisted of a containment cell, two treatment systems, four associated waste staging and storage areas, and support areas; all were used for management of remediation wastes between 1997 and 2003.
Temperature/Humidity Conditions in Stacked Flexible Intermediate Bulk Containers for Shelled Peanuts
USDA-ARS?s Scientific Manuscript database
Shelled peanuts are loaded into flexible intermediate bulk containers, or totes. After loading, the 1000-kg totes are placed directly into cold storage at 3ºC and 65% relative humidity until shipment to the customer domestically in the United States or internationally requiring transport overseas. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mattlin, E.; Charboneau, S.; Johnston, G.
2007-07-01
The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the Resource Conservation and Recovery Act of 1976 (RCRA) and Washington State Hazardous Waste Management Act, RCW 70.105, , have been deactivated and are being actively decommissioned under the provisions of the Hanford Federal Facility Agreement and Consent Order (HFFACO), RCRA and Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 42 U.S.C. 9601 et seq. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4,more » D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building. The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground piping from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions will address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the Hanford Facility Dangerous Waste Closure Plan, 241-Z Treatment and Storage Tanks. Under the RCRA closure plan, the 241-Z TSD unit is anticipated to undergo clean closure to the performance standards of the State of Washington with respect to dangerous waste contamination from RCRA operations. The TSD unit will be clean closed if physical closure activities identified in the plan achieve clean closure standards for all 241-Z locations. Clean closed 241-Z treatment and storage tanks, equipment and/or structures will remain after RCRA clean closure for future disposition in conjunction with PFP decommissioning activities which are integrated with CERCLA. (authors)« less
Nilsson, Louise K J; Sharma, Anil; Bhatnagar, Raj K; Bertilsson, Stefan; Terenius, Olle
2018-06-01
Water-storage containers are common in households where access to water is scarce and often act as breeding sites for vector mosquitoes. Bacteria in these containers may be important for attracting or repelling ovipositing mosquitoes. We hypothesized that bacterial community composition in water-storage containers would represent either inhibitory or suitable environmental conditions for mosquito larvae. To investigate this, we characterized the bacterial community composition in water-storage containers and correlated these communities to Aedes and Anopheles larval densities. Water samples were collected over two years from 13 containers in an Indian village and analyzed by high throughput 16S rRNA gene amplicon sequencing. Comparisons of bacterial community composition between water with and without mosquito larvae showed that Xanthomonadaceae, Comamonadaceae and Burkholderiaceae were more common (P < 0.05) in absence of larvae, while Lachnospiraceae, Synechococcaceae, Alcaligenaceae and Cryomorphaceae were more common (P < 0.05) in presence of larvae. Indicator analysis identified operational taxonomic units designated as CL500-29 marine group (Acidimicrobiaceae) and FukuN101 (Microbacteriaceae) for absence and presence of larvae, respectively. These results contribute to the understanding of which bacteria, directly or indirectly, can be linked to absence or presence of mosquitoes around households and set the basis for potential measures to be taken against these vector mosquitoes.
NASA Astrophysics Data System (ADS)
Zou, Chenlu; Cui, Xue; Wang, Heng; Zhou, Bin; Liu, Yang
2018-01-01
In the case of rapid development of wind power and heavy wind curtailment, the study of wind power accommodation of combined heat and power system has become the focus of attention. A two-stage scheduling model contains of wind power, thermal energy storage, CHP unit and flexible load were constructed. This model with the objective function of minimizing wind curtailment and the operation cost of units while taking into account of the total coal consumption of units, constraint of thermal energy storage and electricity-heat characteristic of CHP. This paper uses MICA to solve the problem of too many constraints and make the solution more feasible. A numerical example showed that the two stage decision scheduling model can consume more wind power, and it could provide a reference for combined heat and power system short-term operation
Wagner, Stephen J; Skripchenko, Andrey; Myrup, Andrew; Thompson-Montgomery, Dedeene; Awatefe, Helen; Moroff, Gary
2010-05-01
Commercially available additive solutions (ASs) require 30% to 35% plasma for optimal storage of platelets (PLTs). PLTs suspended in M-sol, a bicarbonate-based experimental platelet additive solution (PAS), maintain in vitro PLT properties during storage with low levels of plasma (< or =5%). Four different formulations of M-sol were prepared at the optimal pH (6.1): M-sol, M-sol without calcium, M-sol without citric acid, and M-sol without calcium and citric acid. Apheresis PLT units (100% plasma) were equally divided into five 50-mL aliquots in PL732 containers, centrifuged, and resuspended to prepare units suspended in the four different PASs (95%) with 5% plasma and 1 unit in 100% plasma. Units (n = 10) were stored under standard conditions and assayed for in vitro properties on Days 1, 5, and 7. The data were analyzed by analysis of variance for repeated measures (n = 10, p < 0.001). On Day 5 of storage, PLTs suspended in the M-sol formulation containing calcium but lacking citric acid had similar pH, extent of shape change (ESC) values, and percentage of CD62-positive PLTs and greater hypotonic shock response (HSR) and percentage of discoid PLTs compared to those of PLTs suspended in 100% plasma. In contrast, PLTs suspended in the M-sol formulation lacking calcium had lesser ESC values, greater percentage of CD62-positive PLTs, and similar HSR values and percentage of discoid PLTs compared to those of PLTs suspended in 100% plasma on Day 5 (p < 0.001). Calcium plays an important role in maintaining CD62-negative PLTs and relatively high ESC in 5% plasma. The removal of citric acid from M-sol may improve PLT storage properties with low plasma levels.
Development of an integrated heat pipe-thermal storage system for a solar receiver
NASA Technical Reports Server (NTRS)
Keddy, E.; Sena, J. Tom; Merrigan, M.; Heidenreich, Gary; Johnson, Steve
1988-01-01
An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
What do the CERES Product Levels represent?
Atmospheric Science Data Center
2014-12-08
... Products Level 1B Data products are processed to sensor units. The BDS product contains CERES ... between average global net TOA flux imbalance and ocean heat storage). EBAF CERES: Product Questions ...
Geologic framework for the national assessment of carbon dioxide storage resources
Warwick, Peter D.; Corum, Margo D.
2012-01-01
The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2) and to consult with other Federal and State agencies to locate the pertinent geological data needed for the assessment. The geologic sequestration of CO2 is one possible way to mitigate its effects on climate change. The methodology used for the national CO2 assessment (Open-File Report 2010-1127; http://pubs.usgs.gov/of/2010/1127/) is based on previous USGS probabilistic oil and gas assessment methodologies. The methodology is non-economic and intended to be used at regional to subbasinal scales. The operational unit of the assessment is a storage assessment unit (SAU), composed of a porous storage formation with fluid flow and an overlying sealing unit with low permeability. Assessments are conducted at the SAU level and are aggregated to basinal and regional results. This report identifies and contains geologic descriptions of SAUs in separate packages of sedimentary rocks within the assessed basin and focuses on the particular characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU such as depth to top, gross thickness, net porous thickness, porosity, permeability, groundwater quality, and structural reservoir traps are provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information included here will be employed, as specified in the methodology, to calculate a statistical Monte Carlo-based distribution of potential storage space in the various SAUs. Figures in this report show SAU boundaries and cell maps of well penetrations through the sealing unit into the top of the storage formation. Wells sharing the same well borehole are treated as a single penetration. Cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on cell maps.
The Army’s Use of Containerization for Unit Deployments
1991-12-07
Because of their lack of MHE, they may require a smaller container size, like the old CONEX, that can be either man -handled or moved with a 10-ton...equipment. As a general rule, a unit should not take additional containers that will serve only as storage facilities or workplaces in the wartime area of...seamen required to man the existing reserve vessels; provides the govemrnment access to a ’healthy, source of shipping vt.’saels versus relying totally on
NASA Astrophysics Data System (ADS)
Li, Shuang-Fei; Wang, Ping-Yang; Liu, Zhen-hua
2018-05-01
This study proposed a novel thermosyphon-type thermal storage unit using water-based CuO nanofluid as the phase-change heat transfer medium. Seven tubular canisters containing solid-liquid phase-change material (PCM) with peak melting temperature of 100 °C were placed vertically into the center of the TSU which is a vertical cylindrical vessel made of stainless steel. Coat formed by depositing nanoparticles during the phase-change process was adopted to increase the wettability of the heat transfer surfaces of the canisters. We investigated the phase-change heat transfer, as well as the heat-storage and heat-release properties, of the TSU through experimental and computational analysis. Our results demonstrate that this thermal storage unit construction can propose good heat transfer and heat-storage/heat-release performance. The coating of nanoparticles onto the heat transfer surfaces increases the surface wettability and improves both the evaporation and condensation heat transfer. The main thermal resistance in the TSU results from the conductive heat transfer inside of the PCM. All phase-change thermal resistance of liquid film in charging and discharging processes can be ignored in this TSU.
Jenkins, W. J.; Blagdon, J.
1971-01-01
Considerable experience has been gained in the operation of a bank of blood frozen in liquid nitrogen. The procedure for freezing and recovering the red cells is, in principle, that described by Krijnen, Kuivenhoven, and de Wit (1970). An improved metal freezing container offers greater freedom from liquid nitrogen leaks and hence, bacterial contamination. Over 500 units of blood have been preserved and used for transfusions without mishap, and many advantages are seen in this relatively economical method for the long-term storage of blood. Images PMID:5130533
Design and demonstration of a storage assisted air conditioning system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-04-01
One phase-change material, sodium sulfate decahydrate, has generated considerable interest for thermal storage. A form of this material containing salts to adjust the transition point to approximately 55/sup 0/F and a gelling agent to prevent segregation of the salts has been developed. This material is packaged in the form of a CHUB, (a cylinder two inches in diameter and twenty inches long) having a weight of 3.25 pounds and a thermal storage capability of 50 Btu per pound. Under this project, a storage-assisted (partial storage) air conditioning system was designed, installed, monitored and evaluated in a typical residential application. Thismore » feasibility demonstration was conducted under the direction of the Long Island Lighting Company in a single family residence in Melville, Long Island, New York. The demonstration system consisted of a CHUB thermal storage system utilized in conjunction with a one and one-half ton air conditioning unit to cool a house that would normally require a two and one half ton air conditioning unit.« less
Drake II, Ronald M.; Brennan, Sean T.; Covault, Jacob A.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.
2014-01-01
This is a report about the geologic characteristics of five storage assessment units (SAUs) within the Denver Basin of Colorado, Wyoming, and Nebraska. These SAUs are Cretaceous in age and include (1) the Plainview and Lytle Formations, (2) the Muddy Sandstone, (3) the Greenhorn Limestone, (4) the Niobrara Formation and Codell Sandstone, and (5) the Terry and Hygiene Sandstone Members. The described characteristics, as specified in the methodology, affect the potential carbon dioxide storage resource in the SAUs. The specific geologic and petrophysical properties of interest include depth to the top of the storage formation, average thickness, net-porous thickness, porosity, permeability, groundwater quality, and the area of structural reservoir traps. Descriptions of the SAU boundaries and the overlying sealing units are also included. Assessment results are not contained in this report; however, the geologic information included here will be used to calculate a statistical Monte Carlo-based distribution of potential storage volume in the SAUs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagpal, J.M.; Joshi, G.C.; Aswal, D.S.
1995-04-01
The high octane gasoline pool contains varying amounts of cracked naphthas as an important ingredient in formulating high octane lead free gasoline. The cracked naphthas are largely from Fluidized Catalytic Cracking (FCC) units and to lesser extend from thermal cracking units. While the role of olefinic unsaturation in gum formation during storage of gasoline has been extensively studied, there is little published work on contribution of individual olefin types in storage stability and gum formation tendency of gasoline containing these compound types. In the present work we report our results on storage stability and gum formation tendency of different olefinmore » types present in cracked naphthas through model compound matrix. It is found that cyclic olefins and cyclic diolefins are the most prolific gum formers. We have also studied the role of sulfur compounds present in the gasolines on gum formation tendency of olefins. While thiols enhance gum formation from all olefinic types, sulfides and disulfides interact depending on the structure of olefins. These can have either an accelerating, or inhibiting effect on gum formation.« less
Livermore Site Spill Prevention, Control, and Countermeasures (SPCC) Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bellah, W.; Griffin, D.; Mertesdorf, E.
This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Livermore Site in Livermore, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations (40 CFR), Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 ofmore » the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at the Livermore Site.« less
Modelling surface-water depression storage in a Prairie Pothole Region
Hay, Lauren E.; Norton, Parker A.; Viger, Roland; Markstrom, Steven; Regan, R. Steven; Vanderhoof, Melanie
2018-01-01
In this study, the Precipitation-Runoff Modelling System (PRMS) was used to simulate changes in surface-water depression storage in the 1,126-km2 Upper Pipestem Creek basin located within the Prairie Pothole Region of North Dakota, USA. The Prairie Pothole Region is characterized by millions of small water bodies (or surface-water depressions) that provide numerous ecosystem services and are considered an important contribution to the hydrologic cycle. The Upper Pipestem PRMS model was extracted from the U.S. Geological Survey's (USGS) National Hydrologic Model (NHM), developed to support consistent hydrologic modelling across the conterminous United States. The Geospatial Fabric database, created for the USGS NHM, contains hydrologic model parameter values derived from datasets that characterize the physical features of the entire conterminous United States for 109,951 hydrologic response units. Each hydrologic response unit in the Geospatial Fabric was parameterized using aggregated surface-water depression area derived from the National Hydrography Dataset Plus, an integrated suite of application-ready geospatial datasets. This paper presents a calibration strategy for the Upper Pipestem PRMS model that uses normalized lake elevation measurements to calibrate the parameters influencing simulated fractional surface-water depression storage. Results indicate that inclusion of measurements that give an indication of the change in surface-water depression storage in the calibration procedure resulted in accurate changes in surface-water depression storage in the water balance. Regionalized parameterization of the USGS NHM will require a proxy for change in surface-storage to accurately parameterize surface-water depression storage within the USGS NHM.
Buursink, Marc L.; Craddock, William H.; Blondes, Madalyn S.; Freeman, Phillip A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.
2013-01-01
2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows that of previous USGS work. This methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of three storage assessment units (SAUs) in Upper Cambrian to Mississippian sedimentary rocks within the Arkoma Basin study area, and two SAUs in Upper Cambrian to Mississippian sedimentary rocks within the Kansas Basins study area. The Arkoma Basin and Kansas Basins are adjacent with very similar geologic units; although the Kansas Basins area is larger, the Arkoma Basin is more structurally complex. The report focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in the SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are usually provided to illustrate geologic factors critical to the assessment. Although assessment results are not contained in this report, the geologic information herein was employed, as specified in the USGS methodology, to calculate a probabilistic distribution of potential storage resources in each SAU. The Midcontinent Rift Basin study area was not assessed, because no suitable storage formations meeting our size, depth, reservoir quality, and regional seal guidelines were found. Figures in this report show study area boundaries along with the SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one-square mile and are derived from interpretations of incompletely attributed well data and from a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on the cell maps.
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
Experimental investigation on AC unit integrated with sensible heat storage (SHS)
NASA Astrophysics Data System (ADS)
Aziz, N. A.; Amin, N. A. M.; Majid, M. S. A.; Hussin, A.; Zhubir, S.
2017-10-01
The growth in population and economy has increases the energy demand and raises the concerns over the sustainable energy source. Towards the sustainable development, energy efficiency in buildings has become a prime objective. In this paper, the integration of thermal energy storage was studied. This paper presents an experimental investigation on the performance of an air conditioning unit integrated with sensible heat storage (SHS) system. The results were compared to the conventional AC systems in the terms of average electricity usage, indoor temperature and the relative humidity inside the experimented room (cabin container). Results show that the integration of water tank as an SHS reduces the electricity usage by 5%, while the integration of well-insulated water tank saves up to 8% of the electricity consumption.
SIMS prototype system 4: Design data brochure
NASA Technical Reports Server (NTRS)
1978-01-01
A pre-package prototype unit having domestic hot water and room solar heating capability that uses air as the collector fluid is described. This system is designed to be used with a small single-family dwelling where a roof mounted collector array is not feasible. The prototype unit is an assemble containing 203 square feet of effective collector surface with 113 cubic feet of rock storage. The design of structure and storage is modular, which permits expansion and reduction of the collector array and storage bed in 68 square feet and 37 cubic feet increments respectively. The system is designed to be transportable. This permitted assemble and certification testing in one area and installation in another area without tear down and reassemble. Design, installation, operation, performance and maintenance of this system are described.
Development of a Probabilistic Assessment Methodology for Evaluation of Carbon Dioxide Storage
Burruss, Robert A.; Brennan, Sean T.; Freeman, P.A.; Merrill, Matthew D.; Ruppert, Leslie F.; Becker, Mark F.; Herkelrath, William N.; Kharaka, Yousif K.; Neuzil, Christopher E.; Swanson, Sharon M.; Cook, Troy A.; Klett, Timothy R.; Nelson, Philip H.; Schenk, Christopher J.
2009-01-01
This report describes a probabilistic assessment methodology developed by the U.S. Geological Survey (USGS) for evaluation of the resource potential for storage of carbon dioxide (CO2) in the subsurface of the United States as authorized by the Energy Independence and Security Act (Public Law 110-140, 2007). The methodology is based on USGS assessment methodologies for oil and gas resources created and refined over the last 30 years. The resource that is evaluated is the volume of pore space in the subsurface in the depth range of 3,000 to 13,000 feet that can be described within a geologically defined storage assessment unit consisting of a storage formation and an enclosing seal formation. Storage assessment units are divided into physical traps (PTs), which in most cases are oil and gas reservoirs, and the surrounding saline formation (SF), which encompasses the remainder of the storage formation. The storage resource is determined separately for these two types of storage. Monte Carlo simulation methods are used to calculate a distribution of the potential storage size for individual PTs and the SF. To estimate the aggregate storage resource of all PTs, a second Monte Carlo simulation step is used to sample the size and number of PTs. The probability of successful storage for individual PTs or the entire SF, defined in this methodology by the likelihood that the amount of CO2 stored will be greater than a prescribed minimum, is based on an estimate of the probability of containment using present-day geologic knowledge. The report concludes with a brief discussion of needed research data that could be used to refine assessment methodologies for CO2 sequestration.
Carbon dioxide fluid-flow modeling and injectivity calculations
Burke, Lauri
2011-01-01
These results were used to classify subsurface formations into three permeability classifications for the probabilistic calculations of storage efficiency and containment risk of the U.S. Geological Survey geologic carbon sequestration assessment methodology. This methodology is currently in use to determine the total carbon dioxide containment capacity of the onshore and State waters areas of the United States.
40 CFR 270.300 - What container information must I keep at my facility?
Code of Federal Regulations, 2011 CFR
2011-07-01
... RCRA Standardized Permits for Storage and Treatment Units Information That Must Be Kept at Your...), including: (1) Test procedures and results or other documentation or information to show that the wastes do...
40 CFR 270.300 - What container information must I keep at my facility?
Code of Federal Regulations, 2012 CFR
2012-07-01
... RCRA Standardized Permits for Storage and Treatment Units Information That Must Be Kept at Your...), including: (1) Test procedures and results or other documentation or information to show that the wastes do...
Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith
NASA Technical Reports Server (NTRS)
Walton, Otis R.; Vollmer, Hubert J.
2013-01-01
Under microgravity, the usual methods of placing granular solids into, or extracting them from, containers or storage vessels will not function. Alternative methods are required to provide a motive force to move the material. New configurations for microgravity regolith storage vessels that do not resemble terrestrial silos, hoppers, or tanks are proposed. The microgravity-compatible bulk-material storage vessels and exit feed configurations are designed to reliably empty and feed cohesive material to transfer vessels or conveying ducts or lines without gravity. A controllable motive force drives the cohesive material to the exit opening(s), and provides a reliable means to empty storage vessels and/or to feed microgravity conveying lines. The proposed designs will function equally well in vacuum, or inside of pressurized enclosures. Typical terrestrial granular solids handling and storage equipment will not function under microgravity, since almost all such equipment relies on gravity to at least move material to an exit location or to place it in the bottom of a container. Under microgravity, there effectively are no directions of up or down, and in order to effect movement of material, some other motive force must be applied to the material. The proposed storage vessels utilize dynamic centrifugal force to effect movement of regolith whenever material needs to be removed from the storage vessel. During simple storage, no dynamic motion or forces are required. The rotation rate during emptying can be controlled to ensure that material will move to the desired exit opening, even if the material is highly cohesive, or has acquired an electrostatic charge. The general concept of this Swirl Action Utilized for Centrifugal Ejection of Regolith (SAUCER) microgravity storage unit/dynamic feeder is to have an effective slot-hopper (based on the converging angles of the top and bottom conical section of the vessel) with an exit slot around the entire periphery of the SAUCER. The basic shape of such a unit is like two Chinese straw hats (douli) - one upside down, on the bottom, and another on top; or two wokpans, one upright on the bottom and another inverted on top, with a small gap between the upright and inverted pans or hats (around the periphery). A stationary outer ring, much like an unmounted bicycle tire, surrounds the gap between the two coaxial, nearly conical pieces, forming the top and bottom of the unit.
Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects
Kriebardis, Anastasios G.; Antonelou, Marianna H.; Georgatzakou, Hara T.; Tzounakas, Vassilis L.; Stamoulis, Konstantinos E.; Papassideri, Issidora S.
2016-01-01
Background Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Materials and methods Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors’ haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Results Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. Discussion The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles. PMID:27136430
Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.
Kriebardis, Anastasios G; Antonelou, Marianna H; Georgatzakou, Hara T; Tzounakas, Vassilis L; Stamoulis, Konstantinos E; Papassideri, Issidora S
2016-05-01
Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors' haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles.
BAG PASSOUT SEALER FOR WATER-SHIELDED CAVE FACILITY (Engineering Materials)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1963-10-31
The water-shielded cave facility is used in processing irradiated slugs for recovery of americium, curium, berkelium, californium, einsteinium, and fermium. The remotely operated, plastic-bag passout sealer is used in removing isotopic fractions for storage in the rear or for removing radioactive waste for placement in the waste storage containers. The unit is accessible by both the primary inclosure master-slaves and the service area master-slaves. (F.L.S.)
High-temperature thermal storage systems for advanced solar receivers materials selections
NASA Astrophysics Data System (ADS)
Wilson, D. F.; Devan, J. H.; Howell, M.
1990-09-01
Advanced space power systems that use solar energy and Brayton or Stirling heat engines require thermal energy storage (TES) systems to operate continuously through periods of shade. The receiver storage units, key elements in both Brayton and Stirling systems, are designed to use the latent heat of fusion of phase-change materials (PCMs). The power systems under current consideration for near-future National Aeronautics and Space Administration space missions require working fluid temperatures in the 1100 to 1400 K range. The PCMs under current investigation that gave liquid temperatures within this range are the fluoride family of salts. However, these salts have low thermal conductivity, which causes large temperature gradients in the storage systems. Improvements can be obtained, however, with the use of thermal conductivity enhancements or metallic PCMs. In fact, if suitable containment materials can be found, the use of metallic PCMs would virtually eliminate the orbit associated temperature variations in TES systems. The high thermal conductivity and generally low volume change on melting of germanium and alloys based on silicon make them attractive for storage of thermal energy in space power systems. An approach to solving the containment problem, involving both chemical and physical compatibility, preparation of NiSi/NiSi2, and initial results for containment of germanium and NiSi/NiSi2, are presented.
High-temperature thermal storage systems for advanced solar receivers materials selections
NASA Technical Reports Server (NTRS)
Wilson, D. F.; Devan, J. H.; Howell, M.
1990-01-01
Advanced space power systems that use solar energy and Brayton or Stirling heat engines require thermal energy storage (TES) systems to operate continuously through periods of shade. The receiver storage units, key elements in both Brayton and Stirling systems, are designed to use the latent heat of fusion of phase-change materials (PCMs). The power systems under current consideration for near-future National Aeronautics and Space Administration space missions require working fluid temperatures in the 1100 to 1400 K range. The PCMs under current investigation that gave liquid temperatures within this range are the fluoride family of salts. However, these salts have low thermal conductivity, which causes large temperature gradients in the storage systems. Improvements can be obtained, however, with the use of thermal conductivity enhancements or metallic PCMs. In fact, if suitable containment materials can be found, the use of metallic PCMs would virtually eliminate the orbit associated temperature variations in TES systems. The high thermal conductivity and generally low volume change on melting of germanium and alloys based on silicon make them attractive for storage of thermal energy in space power systems. An approach to solving the containment problem, involving both chemical and physical compatibility, preparation of NiSi/NiSi2, and initial results for containment of germanium and NiSi/NiSi2, are presented.
Composition and method for hydrogen storage
NASA Technical Reports Server (NTRS)
Mao, Wendy L. (Inventor); Mao, Ho-Kwang (Inventor)
2004-01-01
A method for hydrogen storage includes providing water and hydrogen gas to a containment volume, reducing the temperature of the water and hydrogen gas to form a hydrogen clathrate at a first cryogenic temperature and a first pressure and maintaining the hydrogen clathrate at second cryogenic temperature within a temperature range of up to 250 K to effect hydrogen storage. The low-pressure hydrogen hydrate includes H.sub.2 O molecules, H.sub.2 molecules and a unit cell including polyhedron cages of hydrogen-bonded frameworks of the H.sub.2 O molecules built around the H.sub.2 molecules.
Design of the Heat Receiver for the U.S./Russia Solar Dynamic Power Joint Flight Demonstration
NASA Technical Reports Server (NTRS)
Strumpf, Hal J.; Krystkowiak, Christopher; Klucher, Beth A.
1996-01-01
A joint U.S./Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle Carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium difluoride as the thermal storage solid-to-liquid phase change materiaL This thermal storage is required to enable power production during eclipse. The phase change material is contained in a series of individual containment canisters.
300 Area waste acid treatment system closure plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
LUKE, S.N.
1999-05-17
The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOERL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion includes closure plan documentation submitted for individual, treatment, storage, and/or disposal units undergoing closure, such as the 300 Area Waste Acid Treatment System. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Whenever appropriate, 300 Area Waste Acid Treatment System documentation makes cross-reference to themore » General Information Portion, rather than duplicating text. This 300 Area Waste Acid Treatment System Closure Plan (Revision 2) includes a Hanford Facility Dangerous Waste Permit Application, Part A, Form 3. Information provided in this closure plan is current as of April 1999.« less
Data reported on the long form of the 1990 United State Census were used to identify the number of households in each census block group that obtained water from a private source. A data file was purchased form ESRI Business Solutions (ESRI, 2009) that contained the latitude and ...
Conditioning of the 4 Curies Radium-226 Sealed Radiation Source in Thailand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Punnachaiya, M.; Sawangsri, T.; Wanabongse, P.
This paper describes the conditioning of the 4 curies Radium-226 (Ra-226) sealed radiation source using as a teletherapy unit for cancer treatment in Thailand. The conditioning was under the International Atomic Energy Agency (IAEA) supervision and budgetary supports, comprised of 6 operational steps: the surface dose rate and actual dimension of radium unit measurements, the appropriate lead shielding design with IAEA approval, confirmation of radioactive contamination before conditioning (smear test and radon gas leakage test), transfer of radium source unit into the designed shielding, confirmation of radioactive contamination and dose rate measurement after conditioning, and transportation of Ra-226 conditioning wastemore » package to OAP interim waste storage. The Ra-226 unit was taken out of OAP temporary waste storage for the surface dose rate and the actual dimension measurements behind the 12 inches thick heavy concrete shielding. The maximum measured surface dose rate was 70 R/hr. The special lead container was designed according to its surface dose rate along the source unit which the maximum permissible dose limit for surface dose rate of waste package after conditioning at 2 mSv/hr was applied. The IAEA approved container had total weight of 2.4 ton. After the confirmation of radioactive contamination, Ra-226 source unit was transferred and loaded in the designed lead shielding within 2 minutes. The results of smear test before and after conditioning including radon gas leakage test revealed that there was no radioactive contamination. After conditioning, the surface dose rate measured on the top, bottom were 15,10 mR/hr and varied from 6 - 50 mR/hr around lead container. The Ra-226 conditioning waste package was safely transported to store in OAP interim waste storage. Total working time including the time consumed for radon gas leakage test was 3.5 hours. The total radiation dose received by 16 operators, were ranged from 1 - 69.84 {mu}Sv and the operational team completed the conditioning safely within the effective dose limit for occupational exposure of 50 mSv/year (200 {mu}Sv/day). (authors)« less
International Space Station (ISS) Orbital Replaceable Unit (ORU) Wet Storage Risk Assessment
NASA Technical Reports Server (NTRS)
Squire, Michael D.; Rotter, Henry A.; Lee, Jason; Packham, Nigel; Brady, Timothy K.; Kelly, Robert; Ott, C. Mark
2014-01-01
The International Space Station (ISS) Program requested the NASA Engineering and Safety Center (NESC) to evaluate the risks posed by the practice of long-term wet storage of ISS Environmental Control and Life Support (ECLS) regeneration system orbital replacement units (ORUs). The ISS ECLS regeneration system removes water from urine and humidity condensate and converts it into potable water and oxygen. A total of 29 ORUs are in the ECLS system, each designed to be replaced by the ISS crew when necessary. The NESC assembled a team to review the ISS ECLS regeneration system and evaluate the potential for biofouling and corrosion. This document contains the outcome of the evaluation.
Geomechanical behavior of the reservoir and caprock system at the In Salah CO2 storage project.
White, Joshua A; Chiaramonte, Laura; Ezzedine, Souheil; Foxall, William; Hao, Yue; Ramirez, Abelardo; McNab, Walt
2014-06-17
Almost 4 million metric tons of CO2 were injected at the In Salah CO2 storage site between 2004 and 2011. Storage integrity at the site is provided by a 950-m-thick caprock that sits above the injection interval. This caprock consists of a number of low-permeability units that work together to limit vertical fluid migration. These are grouped into main caprock units, providing the primary seal, and lower caprock units, providing an additional buffer and some secondary storage capacity. Monitoring observations at the site indirectly suggest that pressure, and probably CO2, have migrated upward into the lower portion of the caprock. Although there are no indications that the overall storage integrity has been compromised, these observations raise interesting questions about the geomechanical behavior of the system. Several hypotheses have been put forward to explain the measured pressure, seismic, and surface deformation behavior. These include fault leakage, flow through preexisting fractures, and the possibility that injection pressures induced hydraulic fractures. This work evaluates these hypotheses in light of the available data. We suggest that the simplest and most likely explanation for the observations is that a portion of the lower caprock was hydrofractured, although interaction with preexisting fractures may have played a significant role. There are no indications, however, that the overall storage complex has been compromised, and several independent data sets demonstrate that CO2 is contained in the confinement zone.
303-K Storage Facility closure plan. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-12-15
Recyclable scrap uranium with zircaloy-2 and copper silicon alloy, uranium-titanium alloy, beryllium/zircaloy-2 alloy, and zircaloy-2 chips and fines were secured in concrete billets (7.5-gallon containers) in the 303-K Storage Facility, located in the 300 Area. The beryllium/zircaloy-2 alloy and zircaloy-2 chips and fines are designated as mixed waste with the characteristic of ignitability. The concretion process reduced the ignitability of the fines and chips for safe storage and shipment. This process has been discontinued and the 303-K Storage Facility is now undergoing closure as defined in the Resource Conservation and Recovery Act (RCRA) of 1976 and the Washington Administrative Codemore » (WAC) Dangerous Waste Regulations, WAC 173-303-040. This closure plan presents a description of the 303-K Storage Facility, the history of materials and waste managed, and the procedures that will be followed to close the 303-K Storage Facility. The 303-K Storage Facility is located within the 300-FF-3 (source) and 300-FF-5 (groundwater) operable units, as designated in the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) (Ecology et al. 1992). Contamination in the operable units 300-FF-3 and 300-FF-5 is scheduled to be addressed through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 remedial action process. Therefore, all soil remedial action at the 304 Facility will be conducted as part of the CERCLA remedial action of operable units 300-FF-3 and 300-FF-5.« less
A flexible system to capture sample vials in a storage box - the box vial scanner.
Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D
2009-01-01
Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.
Operation of the 25kW NASA Lewis Research Center Solar Regenerative Fuel Cell Tested Facility
NASA Technical Reports Server (NTRS)
Moore, S. H.; Voecks, G. E.
1997-01-01
Assembly of the NASA Lewis Research Center(LeRC)Solar Regenerative Fuel Cell (RFC) Testbed Facility has been completed and system testing has proceeded. This facility includes the integration of two 25kW photovoltaic solar cell arrays, a 25kW proton exchange membrane (PEM) electrolysis unit, four 5kW PEM fuel cells, high pressure hydrogen and oxygen storage vessels, high purity water storage containers, and computer monitoring, control and data acquisition.
Automated Coal-Mine Shuttle Car
NASA Technical Reports Server (NTRS)
Collins, E. R., Jr.
1984-01-01
Cable-guided car increases efficiency in underground coal mines. Unmanned vehicle contains storage batteries in side panels for driving traction motors located in wheels. Batteries recharged during inactive periods or slid out as unit and replaced by fresh battery bank. Onboard generator charges batteries as car operates.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... following new features: (1) A powerhouse containing two turbine/generator units rated at 2.5 megawatts each... total storage capacity of 33,169 acre-feet at a normal high water level elevation of 4,953 feet mean sea...
NASA Astrophysics Data System (ADS)
Nored, Donald L.
Viewgraphs on Space Station Freedom Electrical Power System (EPS) WP-40 are presented. Topics covered include: key EPS technical requirements; photovoltaic power module systems; solar array assembly; blanket containment box and box positioning subassemblies; solar cell; bypass diode assembly; Kapton with atomic oxygen resistant coating; sequential shunt unit; gimbal assembly; energy storage subsystem; thermal control subsystem; direct current switching unit; integrated equipment assembly; PV cargo element; PMAD system; and PMC and AC architecture.
NASA Technical Reports Server (NTRS)
Nored, Donald L.
1990-01-01
Viewgraphs on Space Station Freedom Electrical Power System (EPS) WP-40 are presented. Topics covered include: key EPS technical requirements; photovoltaic power module systems; solar array assembly; blanket containment box and box positioning subassemblies; solar cell; bypass diode assembly; Kapton with atomic oxygen resistant coating; sequential shunt unit; gimbal assembly; energy storage subsystem; thermal control subsystem; direct current switching unit; integrated equipment assembly; PV cargo element; PMAD system; and PMC and AC architecture.
System design package for SIMS prototype system 4, solar heating and domestic hot water
NASA Technical Reports Server (NTRS)
1978-01-01
The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ludwick, J D; Moore, E B
1984-01-01
Safety and cost information is developed for the conceptual decommissioning of five different types of reference independent spent fuel storage installations (ISFSIs), each of which is being given consideration for interim storage of spent nuclear fuel in the United States. These include one water basin-type ISFSI (wet) and four dry ISFSIs (drywell, silo, vault, and cask). The reference ISFSIs include all component parts necessary for the receipt, handling and storage of spent fuel in a safe and efficient manner. Three decommissioning alternatives are studied to obtain comparisons between costs (in 1981 dollars), occupational radiation doses, and potential radiation doses tomore » the public. The alternatives considered are: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and ENTOMB (entombment followed by long-term surveillance).« less
Heat-Storage Modules Containing LiNO3-3H2O and Graphite Foam
NASA Technical Reports Server (NTRS)
Bootle, John
2008-01-01
A heat-storage module based on a commercial open-cell graphite foam (Poco-Foam or equivalent) imbued with lithium nitrate trihydrate (LiNO3-3H2O) has been developed as a prototype of other such modules for use as short-term heat sources or heat sinks in the temperature range of approximately 28 to 30 C. In this module, the LiNO3-3H2O serves as a phase-change heat-storage material and the graphite foam as thermally conductive filler for transferring heat to or from the phase-change material. In comparison with typical prior heat-storage modules in which paraffins are the phase-change materials and aluminum fins are the thermally conductive fillers, this module has more than twice the heat-storage capacity per unit volume.
Metallic phase-change materials for solar dynamic energy storage systems
NASA Astrophysics Data System (ADS)
Lauf, R. J.; Hamby, C., Jr.
1990-12-01
Solar (thermal) dynamic power systems for satellites require a heat storage system that is capable of operating the engine during eclipse. The conventional approach to this thermal storage problem is to use the latent heat of fluoride salts, which would melt during insolation and freeze during eclipse. Although candidate fluorides have large heats of fusion per unit mass, their poor thermal conductivity limits the rate at which energy can be transferred to and from the storage device. System performance is further limited by the high parasitic mass of the superalloy canisters needed to contain the salt. A new thermal storage system is described in which the phase-change material (PCM) is a metal (typically germanium) contained in modular graphite canisters. These modules exhibit good thermal conductivity and low parasitic mass, and they are physically and chemically stable. Prototype modules have survived over 600 melt/freeze cycles without degradation. Advanced concepts to further improve performance are described. These concepts include the selection of ternary eutectic alloys to provide a wider range of useful melting temperatures and the use of infiltration to control the location of liquid alloy and to compensate for differences in thermal expansion.
Waste Isolation Pilot Plant (WIPP) fact sheet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-10-01
Pursuant to the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act (RCRA), as amended (42 USC 6901, et seq.), and the New Mexico Hazardous Waste Act (Section 74-4-1 et seq., NMSA 1978), Permit is issued to the owner and operator of the US DOE, WIPP site (hereafter called the Permittee(s)) to operate a hazardous waste storage facility consisting of a container storage unit (Waste Handling Building) and two Subpart X miscellaneous below-ground storage units (Bin Scale Test Rooms 1 and 3), all are located at the above location. The Permittee must comply with all termsmore » and conditions of this Permit. This Permit consists of the conditions contained herein, including the attachments. Applicable regulations cited are the New Mexico Hazardous Waste Management Regulations, as amended 1992 (HWMR-7), the regulations that are in effect on the date of permit issuance. This Permit shall become effective upon issuance by the Secretary of the New Mexico Environment Department and shall be in effect for a period of ten (10) years from issuance. This Permit is also based on the assumption that all information contained in the Permit application and the administrative record is accurate and that the activity will be conducted as specified in the application and the administrative record. The Permit application consists of Revision 3, as well as associated attachments and clarifying information submitted on January 25, 1993, and May 17, 1993.« less
NASA Technical Reports Server (NTRS)
Cone, Darren; Greene, Nathanael; Beeson, Harold; McCloskey, David
2013-01-01
Ongoing initiative to get high energy capacity "green fuel" containers to market quickly and cost effectively. The United States has decided to invest in "green energy" technology, to become energy independent, and to "Innovate Our Way to a Clean Energy Future."
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chopra, O.K.; Diercks, D.; Fabian, R.
The cancellation of the Yucca Mountain repository program in the United States raises the prospect of extended long-term storage (i.e., >120 years) and deferred transportation of used fuel at operating and decommissioned nuclear power plant sites. Under U.S. federal regulations contained in Title 10 of the Code of Federal Regulations (CFR) 72.42, the initial license term for an Independent Spent Fuel Storage Installation (ISFSI) must not exceed 40 years from the date of issuance. Licenses may be renewed by the U.S. Nuclear Regulatory Commission (NRC) at the expiration of the license term upon application by the licensee for a periodmore » not to exceed 40 years. Application for ISFSI license renewals must include the following: (1) Time-limited aging analyses (TLAAs) that demonstrate that structures, systems, and components (SSCs) important to safety will continue to perform their intended function for the requested period of extended operation; and (2) a description of the aging management program (AMP) for management of issues associated with aging that could adversely affect SSCs important to safety. In addition, the application must also include design bases information as documented in the most recent updated final safety analysis report as required by 10 CFR 72.70. Information contained in previous applications, statements, or reports filed with the Commission under the license may be incorporated by reference provided that those references are clear and specific. The NRC has recently issued the Standard Review Plan (SRP) for renewal of used-fuel dry cask storage system (DCSS) licenses and Certificates of Compliance (CoCs), NUREG-1927, under which NRC may renew a specific license or a CoC for a term not to exceed 40 years. Both the license and the CoC renewal applications must contain revised technical requirements and operating conditions (fuel storage, surveillance and maintenance, and other requirements) for the ISFSI and DCSS that address aging effects that could affect the safe storage of the used fuel. The information contained in the license and CoC renewal applications will require NRC review to verify that the aging effects on the SSCs in DCSSs/ ISFSIs are adequately managed for the period of extended operation. To date, all of the ISFSIs located across the United States with more than 1,500 dry casks loaded with used fuel have initial license terms of 20 years; three ISFSIs (Surry, H.B. Robinson and Oconee) have received their renewed licenses for 20 years, and two other ISFSIs (Calvert Cliffs and Prairie Island) have applied for license renewal for 40 years. This report examines issues related to managing aging effects on the SSCs in DCSSs/ISFSIs for extended long-term storage and transportation of used fuels, following an approach similar to that of the Generic Aging Lessons Learned (GALL) report, NUREG-1801, for the aging management and license renewal of nuclear power plants. The report contains five chapters and an appendix on quality assurance for aging management programs for used-fuel dry storage systems. Chapter I of the report provides an overview of the ISFSI license renewal process based on 10 CFR 72 and the guidance provided in NUREG-1927. Chapter II contains definitions and terms for structures and components in DCSSs, materials, environments, aging effects, and aging mechanisms. Chapter III and Chapter IV contain generic TLAAs and AMPs, respectively, that have been developed for managing aging effects on the SSCs important to safety in the dry cask storage system designs described in Chapter V. The summary descriptions and tabulations of evaluations of AMPs and TLAAs for the SSCs that are important to safety in Chapter V include DCSS designs (i.e., NUHOMS{reg_sign}, HI-STORM 100, Transnuclear (TN) metal cask, NAC International S/T storage cask, ventilated storage cask (VSC-24), and the Westinghouse MC-10 metal dry storage cask) that have been and continue to be used by utilities across the country for dry storage of used fuel to date. The goal of this report is to help establish the technical basis for extended long-term storage and transportation of used fuel.« less
Buursink, Marc L.; Slucher, Ernie R.; Brennan, Sean T.; Doolan, Colin A.; Drake II, Ronald M.; Merrill, Matthew D.; Warwick, Peter D.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven M.; DeVera, Christina A.; Lohr, Celeste D.
2014-01-01
The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows up on previous USGS work. The methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of 14 storage assessment units (SAUs) in Ordovician to Upper Cretaceous sedimentary rocks within the Greater Green River Basin (GGRB) of Wyoming, Colorado, and Utah, and eight SAUs in Ordovician to Upper Cretaceous sedimentary rocks within the Wyoming-Idaho-Utah Thrust Belt (WIUTB). The GGRB and WIUTB are contiguous with nearly identical geologic units; however, the GGRB is larger in size, whereas the WIUTB is more structurally complex. This report focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in the SAUs. Specific descriptions of the SAU boundaries, as well as their sealing and reservoir units, are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are typically provided to illustrate geologic factors critical to the assessment. This geologic information was employed, as specified in the USGS methodology, to calculate a probabilistic distribution of potential storage resources in each SAU. Figures in this report show SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one square mile and are derived from interpretations of variably attributed well data and a digital compilation that is known not to include all drilling.
A high-speed, large-capacity, 'jukebox' optical disk system
NASA Technical Reports Server (NTRS)
Ammon, G. J.; Calabria, J. A.; Thomas, D. T.
1985-01-01
Two optical disk 'jukebox' mass storage systems which provide access to any data in a store of 10 to the 13th bits (1250G bytes) within six seconds have been developed. The optical disk jukebox system is divided into two units, including a hardware/software controller and a disk drive. The controller provides flexibility and adaptability, through a ROM-based microcode-driven data processor and a ROM-based software-driven control processor. The cartridge storage module contains 125 optical disks housed in protective cartridges. Attention is given to a conceptual view of the disk drive unit, the NASA optical disk system, the NASA database management system configuration, the NASA optical disk system interface, and an open systems interconnect reference model.
Operation and maintenance of the Sol-Dance Building solar system. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaultney, J.R.
1980-07-29
A 16,400 square foot general office facility has its primary heating provided by a flat plate solar system using hydronic storage and water-to-air transfer coils for distribution. Backup heat is provided by 10 individually controlled air source heat pumps ranging from 3 tons to 5 tons in capacity. These heat pumps also contain electric resistive elements for use during extremely low ambient temperatures. Cooling is also provided by the heat pumps. Each of the two buildings contains a separate domestic hot water system. Primary heat is provided by a closed loop solar unit with electric elements providing backup heat. Amore » 10,000 gallon black steel water tank provides heat storage.« less
Magnesium fluoride as energy storage medium for spacecraft solar thermal power systems
NASA Technical Reports Server (NTRS)
Lurio, Charles A.
1992-01-01
MgF2 was investigated as a phase-change energy-storage material for LEO power systems using solar heat to run thermal cycles. It provides a high heat of fusion per unit mass at a high melting point (1536 K). Theoretical evaluation showed the basic chemical compatibility of liquid MgF2 with refractory metals at 1600 K, though transient high pressures of H2 can occur in a closed container due to reaction with residual moisture. The compatibility was tested in two refractory metal containers for over 2000 h. Some showed no deterioration, while there was evidence that the fluoride reacted with hafnium in others. Corollary tests showed that the MgF2 supercooled by 10-30 K and 50-90 K.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-09-01
The decision document presents the selected interim remedial action for Operable Unit 9 (OU9) at the Defense General Supply Center (DGSC) in Chesterfield County, Virginia near Richmond. OU9 pertains to groundwater beneath Area 50, the Open Storage Area (OSA), and the Naitonal Guard Area (NGA). This operable unit is the third of nine operable units that are currently being addressed at the DGSC. OU9 addresses interim treatment and containment of groundwater in the upper and lower aquifers beneath Area 50, the OSA, and the NGA.
31 CFR 411.1 - Color illustrations authorized.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SERVICE, DEPARTMENT OF THE TREASURY COLOR ILLUSTRATIONS OF UNITED STATES CURRENCY § 411.1 Color... necessary plates or items for such printing or publishing, of color illustrations of U.S. currency provided... storage devices, and any other thing used in the making of the illustration that contain an image of the...
Diesel Electrical Systems. Teacher Edition (Revised).
ERIC Educational Resources Information Center
Sprinkle, Tom; Huston, Jane, Ed.
This module is one of a series of teaching guides that cover diesel mechanics. The module contains eight instructional units that cover the following topics: (1) introduction to electrical systems; (2) electrical circuits; (3) electrical indicator circuits; (4) storage batteries; (5) starting systems and circuits; (6) ignition circuits; (7)…
Atmospheric Science Data Center
2013-02-28
... CERES Product Level Details Level 1B: Data products are processed to sensor units. The BDS product contains CERES ... position and velocity, and all raw engineering and status data from the instrument. Level 2: Data products are derived ... between average global net TOA flux imbalance and ocean heat storage). ...
Gallegos, Críspulo; Valencia, Concepción; Partal, Pedro; Franco, José M; Maglio, Omay; Abrahamsson, Malin; Brito-de la Fuente, Edmundo
2012-08-01
The droplet size of commercial fish oil-containing injectable lipid emulsions, including conformance to United States Pharmacopeia (USP) standards on fat-globule size, was investigated. A total of 18 batches of three multichamber parenteral products containing the emulsion SMOFlipid as a component were analyzed. Samples from multiple lots of the products were evaluated to determine compliance with standards on the volume-weighted percentage of fat exceeding 0.05% (PFAT(5)) specified in USP chapter 729 to ensure the physical stability of i.v. lipid emulsions. The products were also analyzed to determine the effects of various storage times (3, 6, 9, and 12 months) and storage temperatures (25, 30, and 40 °C) on product stability. Larger-size lipid particles were quantified via single-particle optical sensing (SPOS). The emulsion's droplet-size distribution was determined via laser light scattering. SPOS and light-scattering analysis demonstrated mean PFAT(5) values well below USP-specified globule-size limits for all the tested products under all study conditions. In addition, emulsion aging at any storage temperature in the range studied did not result in a significant increase of PFAT(5) values, and mean droplet-size values did not change significantly during storage of up to 12 months at temperatures of 25-40 °C. PFAT(5) values were below the USP upper limits in SMOFlipid samples from multiple lots of three multichamber products after up to 12 months of storage at 25 or 30 °C or 6 months of storage at 40 °C.
1998-01-14
The Photovoltaic Module 1 Integrated Equipment Assembly (IEA) is lifted from its container in Kennedy Space Center’s Space Station Processing Facility (SSPF) before it is moved into its workstand, where it will be processed for flight on STS-97, scheduled for launch in April 1999. The IEA is one of four integral units designed to generate, distribute, and store power for the International Space Station. It will carry solar arrays, power storage batteries, power control units, and a thermal control system. The 16-foot-long, 16,850-pound unit is now undergoing preflight preparations in the SSPF
Flow of Cadmium from Rechargeable Batteries in the United States, 1996-2007
Wilburn, David R.
2007-01-01
Cadmium metal has been found to be toxic to humans and the environment under certain conditions; therefore, a thorough understanding of the use and disposal of the metal is warranted. Most of the cadmium used in the United States comes from imported products. In 2007, more than 83 percent of the cadmium used in the United States was contained in batteries, mostly in rechargeable nickel-cadmium batteries used in popular consumer products such as cordless phones and power tools. The flow of cadmium contained in rechageable nickel-cadmium batteries used in the United States was tracked for the years 1996 to 2007. The amount of cadmium metal contained in imported products in 2007 was estimated to be about 1,900 metric tons, or about 160 percent higher than the reported cadmium production in the United States from all primary and secondary sources. Although more than 40,000 metric tons of cadmium was estimated to be contained in nickel-cadmium rechargeable batteries that became obsolete during the 12-year study period, not all of this material was sent to municipal solid waste landfills. About 27 percent of the material available for recovery in the United States was recycled domestically in 2007; the balance was discarded in municipal solid waste landfills, exported for recycling, retained in temporary storage, or thrown away.
Charge storage in oxygen deficient phases of TiO2: defect Physics without defects.
Padilha, A C M; Raebiger, H; Rocha, A R; Dalpian, G M
2016-07-01
Defects in semiconductors can exhibit multiple charge states, which can be used for charge storage applications. Here we consider such charge storage in a series of oxygen deficient phases of TiO2, known as Magnéli phases. These Magnéli phases (TinO2n-1) present well-defined crystalline structures, i.e., their deviation from stoichiometry is accommodated by changes in space group as opposed to point defects. We show that these phases exhibit intermediate bands with an electronic quadruple donor transitions akin to interstitial Ti defect levels in rutile TiO2. Thus, the Magnéli phases behave as if they contained a very large pseudo-defect density: ½ per formula unit TinO2n-1. Depending on the Fermi Energy the whole material will become charged. These crystals are natural charge storage materials with a storage capacity that rivals the best known supercapacitors.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
..., Hewlett Packard Enterprise Business Unit, EG HP Storage, Enterprise Storage, Servers and Networking Storage, APP Management, Research and Development Group, Andover, Massachusetts; Notice of Investigation... Enterprise Business Unit, EG HP Storage, Enterprise Storage, Servers and Networking Storage Division, APP...
Koidis, Anastasios; Rawson, Ashish; Tuohy, Maria; Brunton, Nigel
2012-06-01
Carrots and parsnips are often consumed as minimally processed ready-to-eat convenient foods and contain in minor quantities, bioactive aliphatic C17-polyacetylenes (falcarinol, falcarindiol, falcarindiol-3-acetate). Their retention during minimal processing in an industrial trial was evaluated. Carrot and parsnips were prepared in four different forms (disc cutting, baton cutting, cubing and shredding) and samples were taken in every point of their processing line. The unit operations were: peeling, cutting and washing with chlorinated water and also retention during 7days storage was evaluated. The results showed that the initial unit operations (mainly peeling) influence the polyacetylene retention. This was attributed to the high polyacetylene content of their peels. In most cases, when washing was performed after cutting, less retention was observed possibly due to leakage during tissue damage occurred in the cutting step. The relatively high retention during storage indicates high plant matrix stability. Comparing the behaviour of polyacetylenes in the two vegetables during storage, the results showed that they were slightly more retained in parsnips than in carrots. Unit operations and especially abrasive peeling might need further optimisation to make them gentler and minimise bioactive losses. Copyright © 2011 Elsevier Ltd. All rights reserved.
National assessment of geologic carbon dioxide storage resources: summary
,
2013-01-01
The U.S. Geological Survey (USGS) recently completed an evaluation of the technically accessible storage resource (TASR) for carbon dioxide (CO2) for 36 sedimentary basins in the onshore areas and State waters of the United States. The TASR is an estimate of the geologic storage resource that may be available for CO2 injection and storage and is based on current geologic and hydrologic knowledge of the subsurface and current engineering practices. By using a geology-based probabilistic assessment methodology, the USGS assessment team members obtained a mean estimate of approximately 3,000 metric gigatons (Gt) of subsurface CO2 storage capacity that is technically accessible below onshore areas and State waters; this amount is more than 500 times the 2011 annual U.S. energy-related CO2 emissions of 5.5 Gt (U.S. Energy Information Administration, 2012, http://www.eia.gov/environment/emissions/carbon/). In 2007, the Energy Independence and Security Act (Public Law 110–140) directed the U.S. Geological Survey to conduct a national assessment of geologic storage resources for CO2 in consultation with the U.S. Environmental Protection Agency, the U.S. Department of Energy, and State geological surveys. The USGS developed a methodology to estimate storage resource potential in geologic formations in the United States (Burruss and others, 2009, USGS Open-File Report (OFR) 2009–1035; Brennan and others, 2010, USGS OFR 2010–1127; Blondes, Brennan, and others, 2013, USGS OFR 2013–1055). In 2012, the USGS completed the assessment, and the results are summarized in this Fact Sheet and are provided in more detail in companion reports (U.S. Geological Survey Geologic Carbon Dioxide Storage Resources Assessment Team, 2013a,b; see related reports at right). The goal of this project was to conduct an initial assessment of storage capacity on a regional basis, and results are not intended for use in the evaluation of specific sites for potential CO2 storage. The national assessment was a geology-based examination of all sedimentary basins in the onshore and State waters area of the United States that contain storage assessment units (SAUs) that could be defined according to geologic and hydrologic characteristics. Although geologic storage of CO2 may be possible in some areas not assessed by the USGS, the SAUs identified in this assessment represent those areas within sedimentary basins that met the assessment criteria. A geologic description of each SAU was prepared; descriptions for SAUs in several basins are in Warwick and Corum (2012, USGS OFR 2012–1024).
Development of a high temperature storage unit for integration with solar dynamic systems
NASA Astrophysics Data System (ADS)
Staehle, H. J.; Lindner, F.
1989-08-01
Lithium fluoride in its capacity as a suitable energy storage material is investigated. Energy is stored as latent heat by melting the LiF. The energy is later released during recrystallization of the salt. Drawbacks to this system are described. The high corrosivity in molten state may lead to container failure in long term use. In order to avoid destruction of canisters, a graphite container is developed as graphite is not wetted by liquid LiF and thus does not suffer any corrosion. In order to match the mechanical forces caused by the volume increase during melting, a channel-like internal structure is tested. The melt formed first can expand into these channels and no pressure is built up. The results of these tests are presented.
Magnesium fluoride as energy storage medium for spacecraft solar thermal power systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lurio, C.A.
1992-10-01
MgF2 was investigated as a phase-change energy-storage material for LEO power systems using solar heat to run thermal cycles. It provides a high heat of fusion per unit mass at a high melting point (1536 K). Theoretical evaluation showed the basic chemical compatibility of liquid MgF2 with refractory metals at 1600 K, though transient high pressures of H2 can occur in a closed container due to reaction with residual moisture. The compatibility was tested in two refractory metal containers for over 2000 h. Some showed no deterioration, while there was evidence that the fluoride reacted with hafnium in others. Corollarymore » tests showed that the MgF2 supercooled by 10-30 K and 50-90 K. 24 refs.« less
Multiple Learning Strategies Project. Small Engine Repair Service. [Regular Vocational. Vol. 2.
ERIC Educational Resources Information Center
Pitts, Jim; And Others
This instructional package is one of two designed for use by regular vocational students in the vocational area of small engine repair service. Contained in this document are forty-nine learning modules organized into eleven units: test equipment; motorcycle; engine removal and replacement; machining; tune-ups; short blocks; storage; filling out…
Zhang, Yuzhu; Lee, BoRam; Du, Wen-Xian; Lyu, Shu-Chen; Nadeau, Kari C; Grauke, Larry J; Zhang, Yan; Wang, Shuo; Fan, Yuting; Yi, Jiang; McHugh, Tara H
2016-05-25
The 7S vicilin and 11S legumin seed storage globulins belong to the cupin protein superfamily and are major food allergens in many foods from the "big eight" food allergen groups. Here, for the first time, pecan vicilin was found to be a food allergen. Western blot experiments revealed that 30% of 27 sera used in this study and 24% of the sera from 25 patients with double-blind, placebo controlled clinical pecan allergy contained IgE antibodies specific to pecan vicilin. This allergen consists of a low-complexity region at its N-terminal and a structured domain at the C-terminal that contains two cupin motifs and forms homotrimers. The crystal structure of recombinant pecan vicilin was determined. The refined structure gave R/Rfree values of 0.218/0.262 for all data to 2.65 Å. There were two trimeric biological units in the crystallographic asymmetric unit. Pecan vicilin is also a copper protein. These data may facilitate the understanding of the nutritional value and the allergenicity relevance of the copper binding property of seed storage proteins in tree nuts.
Covault, Jacob A.; Blondes, Madalyn S.; Cahan, Steven M.; DeVera, Christina A.; Freeman, P.A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2013-01-01
The 2007 Energy Independence and Security Act (Public Law 110–140) directs the U.S. Geological Survey (USGS) to conduct a national assessment of potential geologic storage resources for carbon dioxide (CO2). The methodology used by the USGS for the national CO2 assessment follows that of previous USGS work. The methodology is non-economic and intended to be used at regional to subbasinal scales. This report identifies and contains geologic descriptions of three storage assessment units (SAUs) in Eocene and Oligocene sedimentary rocks within the Columbia, Puget, Willapa, Astoria, Nehalem, and Willamette Basins of Oregon, Washington, and Idaho, and focuses on the characteristics, specified in the methodology, that influence the potential CO2 storage resource in those SAUs. Specific descriptions of the SAU boundaries as well as their sealing and reservoir units are included. Properties for each SAU, such as depth to top, gross thickness, porosity, permeability, groundwater quality, and structural reservoir traps, are provided to illustrate geologic factors critical to the assessment. The designated sealing unit in the Columbia Basin is tentatively chosen to be the ubiquitous and thick Miocene Columbia River Basalt Group. As a result of uncertainties regarding the seal integrity of the Columbia River Basalt Group, the SAUs were not quantitatively assessed. Figures in this report show SAU boundaries and cell maps of well penetrations through sealing units into the top of the storage formations. The cell maps show the number of penetrating wells within one square mile and are derived from interpretations of incompletely attributed well data, a digital compilation that is known not to include all drilling. The USGS does not expect to know the location of all wells and cannot guarantee the amount of drilling through specific formations in any given cell shown on the cell maps.
Site 300 Spill Prevention, Control, and Countermeasures (SPCC) Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, D.; Mertesdorf, E.
This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Experimental Test Site (Site 300) near Tracy, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations, Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67more » of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at Site 300. This SPCC Plan has been prepared for the entire Site 300 facility and replaces the three previous plans prepared for Site 300: LLNL SPCC for Electrical Substations Near Buildings 846 and 865 (LLNL 2015), LLNL SPCC for Building 883 (LLNL 2015), and LLNL SPCC for Building 801 (LLNL 2014).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, D.
This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Experimental Test Site (Site 300) near Tracy, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations, Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67more » of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at Site 300. This SPCC Plan has been prepared for the entire Site 300 facility and replaces the three previous plans prepared for Site 300: LLNL SPCC for Electrical Substations Near Buildings 846 and 865 (LLNL 2015), LLNL SPCC for Building 883 (LLNL 2015), and LLNL SPCC for Building 801 (LLNL 2014).« less
21 CFR 864.3250 - Specimen transport and storage container.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Specimen transport and storage container. 864.3250....3250 Specimen transport and storage container. (a) Identification. A specimen transport and storage..., or body exudate during storage and transport in order that the matter contained therein can be...
21 CFR 864.3250 - Specimen transport and storage container.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Specimen transport and storage container. 864.3250....3250 Specimen transport and storage container. (a) Identification. A specimen transport and storage..., or body exudate during storage and transport in order that the matter contained therein can be...
Container for hydrogen isotopes
Solomon, David E.
1977-01-01
A container for the storage, shipping and dispensing of hydrogen isotopes such as hydrogen, deuterium, tritium, or mixtures of the same which has compactness, which is safe against fracture or accident, and which is reusable. The container consists of an outer housing with suitable inlet and outlet openings and electrical feed elements, the housing containing an activated sorber material in the form, for example, of titanium sponge or an activated zirconium aluminate cartridge. The gas to be stored is introduced into the chamber under conditions of heat and vacuum and will be retained in the sorber material. Subsequently, it may be released by heating the unit to drive off the stored gas at desired rates.
Sputtek, Andreas; Lioznov, Michael; Kröger, Nikolaus; Rowe, Arthur W
2011-04-01
We investigated two different plastic freezing bags, namely the most recently U.S. Food and Drug Administration (FDA)-approved CryoMACS(®) freezing bag (200-074-402) from Miltenyi Biotec and the familiar Cryocyte(®) freezing bag (R4R9955) from (Baxter Healthcare, Deerfield, IL, United States) for the cryogenic storage of human hematopoietic progenitor cells (HPC). The study material consisted of 12 frozen HPC pairs (= 24 transplant units) that were no longer needed for autologous treatment of patients. After thawing, one unit of a pair was transferred into the Miltenyi (M) bag; the other unit remained in the original Baxter (B) bag. After refreezing both units, all units were stored again under cryogenic conditions either partially immersed in liquid nitrogen (n = 22) or in the vapor phase over liquid nitrogen, n = 2, <-170°) before thawing. The correlation coefficients (r) between the results obtained from the two bag types were high for white blood cells (WBC) content (r = 0.98), mononuclear cells (MNC) (r = 0.97), lymphocytes (r = 0.98), monocytes (r = 0.96), membrane integrity (r = 0.93), concentration of 'free' hemoglobin (r = 0.97) and hemolysis rate (r = 0.95). With regard to clonogenicity, there were no significant differences (Student's paired t-test) for the three parameters investigated [i.e. total number of colonies, including the numbers of burst-forming units-erythroid (BFU-E) and colony-forming units-granulocyte-macrophage (CFU-GM) colonies, respectively). The CryoMACS freezing bag 200-074-402 is bioequivalent to the Cryocyte freezing container R4R9955. An advantageous feature of the CryoMACS is that its double-sterile wrapping provides additional safety regarding potential cross-contamination during cryogenic storage.
46 CFR 154.1145 - Dry chemical supply.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Dry chemical supply. 154.1145 Section 154.1145 Shipping... Firefighting System: Dry Chemical § 154.1145 Dry chemical supply. (a) A vessel with a cargo carrying capacity less that 1000 m3 (35,300 ft.3) must have at least one self-contained dry chemical storage unit for the...
46 CFR 154.1145 - Dry chemical supply.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Dry chemical supply. 154.1145 Section 154.1145 Shipping... Firefighting System: Dry Chemical § 154.1145 Dry chemical supply. (a) A vessel with a cargo carrying capacity less that 1000 m3 (35,300 ft.3) must have at least one self-contained dry chemical storage unit for the...
46 CFR 154.1145 - Dry chemical supply.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Dry chemical supply. 154.1145 Section 154.1145 Shipping... Firefighting System: Dry Chemical § 154.1145 Dry chemical supply. (a) A vessel with a cargo carrying capacity less that 1000 m3 (35,300 ft.3) must have at least one self-contained dry chemical storage unit for the...
46 CFR 154.1145 - Dry chemical supply.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Dry chemical supply. 154.1145 Section 154.1145 Shipping... Firefighting System: Dry Chemical § 154.1145 Dry chemical supply. (a) A vessel with a cargo carrying capacity less that 1000 m3 (35,300 ft.3) must have at least one self-contained dry chemical storage unit for the...
46 CFR 154.1145 - Dry chemical supply.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Dry chemical supply. 154.1145 Section 154.1145 Shipping... Firefighting System: Dry Chemical § 154.1145 Dry chemical supply. (a) A vessel with a cargo carrying capacity less that 1000 m3 (35,300 ft.3) must have at least one self-contained dry chemical storage unit for the...
Hanford Facility Dangerous Waste Permit Application for T Plant Complex
DOE Office of Scientific and Technical Information (OSTI.GOV)
BARNES, B.M.
2002-09-01
The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to Part B permit application documentation submitted for individual, operating treatment, storage, and/or disposal units, such as the T Plant Complex (this document, DOE/RL-95-36). Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the content of the Part B permit application guidance prepared by the Washington State Department of Ecology (Ecology 1996) and the U.S. Environmental Protection Agencymore » (40 Code of Federal Regulations 270), with additional information needs defined by the Hazardous and Solid Waste Amendments and revisions of Washington Administrative Code 173-303. For ease of reference, the Washington State Department of Ecology alpha-numeric section identifiers from the permit application guidance documentation (Ecology 1996) follow, in brackets, the chapter headings and subheadings. A checklist indicating where information is contained in the T Plant Complex permit application documentation, in relation to the Washington State Department of Ecology guidance, is located in the Contents Section. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Wherever appropriate, the T Plant Complex permit application documentation makes cross-reference to the General Information Portion, rather than duplicating text.« less
Operation ranges and dynamic capabilities of variable-speed pumped-storage hydropower
NASA Astrophysics Data System (ADS)
Mercier, Thomas; Olivier, Mathieu; Dejaeger, Emmanuel
2017-04-01
The development of renewable and intermittent power generation creates incentives for the development of both energy storage solutions and more flexible power generation assets. Pumped-storage hydropower (PSH) is the most established and mature energy storage technology, but recent developments in power electronics have created a renewed interest by providing PSH units with a variable-speed feature, thereby increasing their flexibility. This paper reviews technical considerations related to variable-speed PSH in link with the provision of primary frequency control, also referred to as frequency containment reserves (FCRs). Based on the detailed characteristics of a scale model pump-turbine, the variable-speed operation ranges in pump and turbine modes are precisely assessed and the implications for the provision of FCRs are highlighted. Modelling and control for power system studies are discussed, both for fixed- and variable-speed machines and simulation results are provided to illustrate the high dynamic capabilities of variable-speed PSH.
Craddock, William H.; Buursink, Marc L.; Covault, Jacob A.; Brennan, Sean T.; Doolan, Colin A.; Drake II, Ronald M.; Merrill, Matthew D.; Roberts-Ashby, Tina L.; Slucher, Ernie R.; Warwick, Peter D.; Blondes, Madalyn S.; Freeman, P.A.; Cahan, Steven N.; DeVera, Christina A.; Lohr, Celeste D.; Warwick, Peter D.; Corum, Margo D.
2014-01-01
For each SAU in both of the basins, we discuss the areal distribution of suitable CO2 sequestration reservoir rock. We also characterize the overlying sealing unit and describe the geologic characteristics that influence the potential CO2 storage volume and reservoir performance. These characteristics include reservoir depth, gross thickness, net thickness, porosity, permeability, and groundwater salinity. Case-by-case strategies for estimating the pore volume existing within structurally and (or) stratigraphically closed traps are presented. Although assessment results are not contained in this report, the geologic information included herein was employed to calculate the potential storage volume in the various SAUs. Lastly, in this report, we present the rationale for not conducting assessment work in fifteen sedimentary basins distributed across the Alaskan interior and within Alaskan State waters.
Aerial surveillance vehicles augment security at shipping ports
NASA Astrophysics Data System (ADS)
Huck, Robert C.; Al Akkoumi, Muhammad K.; Cheng, Samuel; Sluss, James J., Jr.; Landers, Thomas L.
2008-10-01
With the ever present threat to commerce, both politically and economically, technological innovations provide a means to secure the transportation infrastructure that will allow efficient and uninterrupted freight-flow operations for trade. Currently, freight coming into United States ports is "spot checked" upon arrival and stored in a container yard while awaiting the next mode of transportation. For the most part, only fences and security patrols protect these container storage yards. To augment these measures, the authors propose the use of aerial surveillance vehicles equipped with video cameras and wireless video downlinks to provide a birds-eye view of port facilities to security control centers and security patrols on the ground. The initial investigation described in this paper demonstrates the use of unmanned aerial surveillance vehicles as a viable method for providing video surveillance of container storage yards. This research provides the foundation for a follow-on project to use autonomous aerial surveillance vehicles coordinated with autonomous ground surveillance vehicles for enhanced port security applications.
National assessment of geologic carbon dioxide storage resources: results
,
2013-01-01
In 2012, the U.S. Geological Survey (USGS) completed an assessment of the technically accessible storage resources (TASR) for carbon dioxide (CO2) in geologic formations underlying the onshore and State waters area of the United States. The formations assessed are at least 3,000 feet (914 meters) below the ground surface. The TASR is an estimate of the CO2 storage resource that may be available for CO2 injection and storage that is based on present-day geologic and hydrologic knowledge of the subsurface and current engineering practices. Individual storage assessment units (SAUs) for 36 basins were defined on the basis of geologic and hydrologic characteristics outlined in the assessment methodology of Brennan and others (2010, USGS Open-File Report 2010–1127) and the subsequent methodology modification and implementation documentation of Blondes, Brennan, and others (2013, USGS Open-File Report 2013–1055). The mean national TASR is approximately 3,000 metric gigatons (Gt). The estimate of the TASR includes buoyant trapping storage resources (BSR), where CO2 can be trapped in structural or stratigraphic closures, and residual trapping storage resources, where CO2 can be held in place by capillary pore pressures in areas outside of buoyant traps. The mean total national BSR is 44 Gt. The residual storage resource consists of three injectivity classes based on reservoir permeability: residual trapping class 1 storage resource (R1SR) represents storage in rocks with permeability greater than 1 darcy (D); residual trapping class 2 storage resource (R2SR) represents storage in rocks with moderate permeability, defined as permeability between 1 millidarcy (mD) and 1 D; and residual trapping class 3 storage resource (R3SR) represents storage in rocks with low permeability, defined as permeability less than 1 mD. The mean national storage resources for rocks in residual trapping classes 1, 2, and 3 are 140 Gt, 2,700 Gt, and 130 Gt, respectively. The known recovery replacement storage resource (KRRSR) is a conservative estimate that represents only the amount of CO2 at subsurface conditions that could replace the volume of known hydrocarbon production. The mean national KRRSR, determined from production volumes rather than the geologic model of buoyant and residual traps that make up TASR, is 13 Gt. The estimated storage resources are dominated by residual trapping class 2, which accounts for 89 percent of the total resources. The Coastal Plains Region of the United States contains the largest storage resource of any region. Within the Coastal Plains Region, the resources from the U.S. Gulf Coast area represent 59 percent of the national CO2 storage capacity.
Freckleton, John R.; Martin, Peter; Nishikawa, Tracy
1998-01-01
The city of Santa Barbara pumps most of its ground water from the Santa Barbara and Foothill ground-water basins. The Santa Barbara basin is subdivided into two storage units: Storage Unit I and Storage Unit III. The Foothill basin and Storage Unit I of the Santa Barbara basin have been studied extensively and ground-water flow models have been developed for them. In this report, the geohydrology of the Santa Barbara ground- water basin is described with a special emphasis on Storage Unit III in the southwestern part of the basin. The purposes of this study were to summarize and evaluate the geohydrology of Storage Unit III and to develop an areawide model of the Santa Barbara and Foothill basins that includes the previously unmodeled Storage Unit III. Storage Unit III is in the southwestern part of the city of Santa Barbara. It is approximately 3.5 miles long and varies in width from about 2,000 feet in the southeast to 4,000 feet in the north-west. Storage Unit III is composed of the Santa Barbara Formation and overlying alluvium. The Santa Barbara Formation (the principal aquifer) consists of Pleistocene and Pliocene(?) unconsolidated marine sand, silt, and clay, and it has a maximum saturated thickness of about 160 feet. The alluvium that overlies the Santa Barbara Formation has a maximum saturated thickness of about 140 feet. The storage unit is bounded areally by faults and low-permeability deposits and is underlain by rocks of Tertiary age. The main sources of recharge to Storage Unit III are seepage from Arroyo Burro and infiltration of precipitation. Most of the recharge occurs in the northwest part of the storage unit, and ground water flows toward the southeast along the unit's long axis. Lesser amounts of recharge may occur as subsurface flow from the Hope Ranch subbasin and as upwelling from the underlying Tertiary rocks. Discharge from Storage Unit III occurs as pumpage, flow to underground drains, underflow through alluvium in the vicinity of Arroyo Burro across the Lavigia Fault, evapotranspiration, and underflow to the Pacific Ocean. The faults that bound Storage Unit III generally are considered to be effective barriers to the flow of ground water. Interbasin ground-water flow occurs where deposits of younger alluvium along stream channels cross faults. Ground-water quality in Storage Unit III deposits varies with location and depth. Upward leakage of poor-quality water from the underlying Tertiary rocks occurs in the storage unit, and such leakage can be influenced by poor well construction or by heavy localized pumping. The highest dissolved-solids concentration (4,710 milligrams per liter) in ground water resulting from this upward leakage is found in the coastal part of the storage unit. The ground-water system was modeled as two horizontal layers. In the Foothill basin and Storage Unit I the layers are separated by a confining bed. The upper layer represents the upper producing zone and the shallow zone near the coast. The lower layer represents the lower producing zone. In general, the faults in the study area were assumed to be no-flow boundaries, except for the offshore fault that forms the southeast boundary; the southeast boundary was simulated as a general-head boundary. The Storage Unit III model was combined with the preexisting Storage Unit I and Foothill basin models, using horizontal flow barriers, to form an areawide model. The areawide model was calibrated by simulating steady-state predevelopment conditions and transient conditions for 1978-92. The nonpumping steady- state simulation was used to verify that the calibrated model yielded physically reasonable results for predevelopment conditions. The calibrated areawide model calculates water levels in Storage Unit III that are within 10 feet of measured water levels at all sites of comparison. In addition, the model adequately simulates water levels in the Storage Unit I and Foothill basin areas. A total of 33,430 acre-feet of water was pum
NASA Astrophysics Data System (ADS)
Lahay, R. R.; Misrun, S.; Sipayung, R.
2018-02-01
Cocoa is plant which it’s seed character is recalcitrant. Giving PEG and using various of storage containers was hoped to increase storage capacity of cocoa seeds as long as period of saving. The reseach was aimed to identify the storage capacity of cocoa seeds through giving PEG in the various of storage containers. Research took place in Hataram Jawa II, Kabupaten Simalungun, Propinsi Sumatera Utara, Indonesia. The method of this research is spit-split plot design with 3 replication. Storage period was put on main plot which was consisted of 4 level, PEG concentration was put on sub plot, consisted of 4 level and storage container was put on the sub sub plot consisted of 3 types. The results showed that until 4 days at storage with 45 % PEG concentration at all storage container, percentage of seed germination at storage can be decreased to be 2.90 %, and can be defensed until 16 days with 45 % PEG concentration at perforated plastic storage container. Percentage of molded seeds and seed moisture content were increased with added period of storage but seed moisture content was increased until 12 days at storage and was decreased at 16 days in storage.
Fraction-storage unit for drug-identification system
NASA Technical Reports Server (NTRS)
Campen, C. F.; Stuart, J. L.
1976-01-01
Device, connecting outputs of all gas chromatographs to single, relatively inexpensive IR spectrometer, reduces costs of system. Storage unit provides buffer storage of samples until infrared spectrometer is ready to accept them. Storage unit can be used to separate overlapping peaks.
40 CFR 267.173 - What standards apply to the container storage areas?
Code of Federal Regulations, 2010 CFR
2010-07-01
... storage areas? 267.173 Section 267.173 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... container storage areas? (a) You must design and operate a containment system for your container storage areas according to the requirements in paragraph (b) of this section, except as otherwise provided by...
Artificial neural networks as quantum associative memory
NASA Astrophysics Data System (ADS)
Hamilton, Kathleen; Schrock, Jonathan; Imam, Neena; Humble, Travis
We present results related to the recall accuracy and capacity of Hopfield networks implemented on commercially available quantum annealers. The use of Hopfield networks and artificial neural networks as content-addressable memories offer robust storage and retrieval of classical information, however, implementation of these models using currently available quantum annealers faces several challenges: the limits of precision when setting synaptic weights, the effects of spurious spin-glass states and minor embedding of densely connected graphs into fixed-connectivity hardware. We consider neural networks which are less than fully-connected, and also consider neural networks which contain multiple sparsely connected clusters. We discuss the effect of weak edge dilution on the accuracy of memory recall, and discuss how the multiple clique structure affects the storage capacity. Our work focuses on storage of patterns which can be embedded into physical hardware containing n < 1000 qubits. This work was supported by the United States Department of Defense and used resources of the Computational Research and Development Programs as Oak Ridge National Laboratory under Contract No. DE-AC0500OR22725 with the U. S. Department of Energy.
Solar heating and cooling diode module
Maloney, Timothy J.
1986-01-01
A high efficiency solar heating system comprising a plurality of hollow modular units each for receiving a thermal storage mass, the units being arranged in stacked relation in the exterior frame of a building, each of the units including a port for filling the unit with the mass, a collector region and a storage region, each region having inner and outer walls, the outer wall of the collector region being oriented for exposure to sunlight for heating the thermal storage mass; the storage region having an opening therein and the collector region having a corresponding opening, the openings being joined for communicating the thermal storage mass between the storage and collector regions by thermosiphoning; the collector region being disposed substantially below and in parallel relation to the storage region in the modular unit; and the inner wall of the collector region of each successive modular unit in the stacked relation extending over the outer wall of the storage region of the next lower modular unit in the stacked relation for reducing heat loss from the system. Various modifications and alternatives are disclosed for both heating and cooling applications.
Kuta, Piotr; Hauck-Dlimi, Barbara; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold
2016-01-01
Uncontrolled hemorrhage in polytrauma patients usually results in rapid need of blood products. Despite the shorter thawing times of microwave devices for heating fresh frozen plasma (FFP), their use has remained controversial, and just a few laboratory analyses have been published on this topic. The aim of this study was to analyse the quality of clotting factors immediately after thawing FFP with a microwave device and after 48-hour post thaw storage at 4 degrees C. 24 FFP units of all four ABO blood groups (six of each blood group) were thawed with a Transfusio-therm 2000 and later stored at 4 degrees C for 48 hours. Samples were drawn aseptically and investigated on various clotting factors and protein proteases (fibrinogen, antithrombin, FII, FV, FVII, FVIII, FIX, FX, FXI, FXIII, vWF antigen and activity, protein S, and protein C) using standard coagulation and chromogenic assays immediately after thawing and again after a 48-hour storage period at 4 degrees C. All units were tested for both anaerobic and aerobic microbial contamination using standard operating procedures immediately after thawing. After thawing, all coagulation factors and protein protease activities were within normal ranges. Blood group O individuals had approximately 25% lower plasma levels of vWF antigen and activity. After a 48-hour storage period at 4 degrees C, FVIII and FIX activities declined significantly in all blood groups, whereas the remaining clotting factors remained comparably stable. Immediately after rapid thawing using a microwave system, all FFP units contained adequate coagulation factor activities to maintain hemostatic activity at the time of product thaw. The post thaw refrigerated storage caused an anticipated decrease in factor VIII and IX activities, but retained normal coagulation factor levels of many plasma proteins. Therefore we conclude that the Transfusio-therm 2000 has no clinically significant influence on the activity of clotting factors and plasma proteases in FFP units.
Geothermal-energy files in computer storage: sites, cities, and industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Dea, P.L.
1981-12-01
The site, city, and industrial files are described. The data presented are from the hydrothermal site file containing about three thousand records which describe some of the principal physical features of hydrothermal resources in the United States. Data elements include: latitude, longitude, township, range, section, surface temperature, subsurface temperature, the field potential, and well depth for commercialization. (MHR)
Shuttle freezer conceptual design
NASA Technical Reports Server (NTRS)
Proctor, B. W.; Russell, D. J.
1975-01-01
A conceptual design for a kit freezer for operation onboard shuttle was developed. The freezer features a self-contained unit which can be mounted in the orbiter crew compartment and is capable of storing food at launch and returning with medical samples. Packaging schemes were investigated to provide the optimum storage capacity with a minimum weight and volume penalty. Several types of refrigeration systems were evaluated to select one which would offer the most efficient performance and lowest hazard of safety to the crew. Detailed performance data on the selected, Stirling cycle principled refrigeration unit were developed to validate the feasibility of its application to this freezer. Thermal analyses were performed to determine the adequacy of the thermal insulation to maintain the desired storage temperature with the design cooling capacity. Stress analyses were made to insure the design structure integrity could be maintained over the shuttle flight regime. A proposed prototype freezer development plan is presented.
Performance of a cylindrical phase-change thermal energy storage unit
NASA Astrophysics Data System (ADS)
Jacobson, D. L.; Ponnappan, R.
1983-05-01
The high-temperature performance of a eutectic salt Phase Change Material (PCM) in a cylindrical Thermal Energy Storage Container (TESC) sample is evaluated by means of an experimental apparatus with a water-circulated calorimeter. The phase change characteristics of the salt during melting and solidification were observed by monitoring the external axial temperature profile of the container, and the analysis of the phase change heat transfer in the cylindrical geometry was based on the modified heat balance integral method of Tien (1980), which provides the solidification rate and time. Melting point (983 K), freezing point (944 K), latent heat of fusion (782.26 J/gm) and thermal diffusivity (0.00799 sq cm/sec) results are in agreement with those found in the literature. The experimental and analytical results of the nondimensionalized heat transfer resistance as a function of the solidified or melted weight fraction are compared.
Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brian B; Achanta, Prasanta K; Maksimovic, Dragan
This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modularmore » structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.« less
Marcos, Begonya; Aymerich, Teresa; Monfort, Josep M; Garriga, Margarita
2007-11-30
The antimicrobial effect against L. monocytogenes of biodegradable films (alginate, zein and polyvinyl alcohol) containing enterocins was investigated. Survival of the pathogen was studied by means of challenge tests performed at 6 degrees C during 8 and 29 days, for air-packed and vacuum-packed sliced cooked ham, respectively. Air packaging was tested with two concentrations of enterocins (200 and 2000 AU/cm2). Control air-packed cooked ham showed an increase of L. monocytogenes from 10(4) to 10(7) CFU/g after 8 days. By contrast, packaging with antimicrobial films effectively slowed down the pathogen's growth, leading to final counts lower than in control lots. Air-packaging with alginate films containing 2000 AU/cm2 of enterocins effectively controlled L. monocytogenes for 8 days. An increase of only 1 log unit was observed in zein and polyvinyl alcohol lots at the same enterocin concentration. Vacuum packaging with films containing enterocins (2000 AU/cm2) also delayed the growth of the pathogen. No increase from inoculated levels was observed during 15 days in antimicrobial alginate films. After 29 days of storage, the lowest counts were obtained in samples packed with zein and alginate films containing enterocins, as well as with zein control films. The most effective treatment for controlling L. monocytogenes during 6 degrees C storage was vacuum-packaging of sliced cooked ham with alginate films containing 2000 AU/cm2 of enterocins. From the results obtained it can concluded that antimicrobial packaging can improve the safety of sliced cooked ham by delaying and reducing the growth of L. monocytogenes.
Organic transistor memory with a charge storage molecular double-floating-gate monolayer.
Tseng, Chiao-Wei; Huang, Ding-Chi; Tao, Yu-Tai
2015-05-13
A flexible, low-voltage, and nonvolatile memory device was fabricated by implanting a functional monolayer on an aluminum oxide dielectric surface in a pentacene-based organic transistor. The monolayer-forming molecule contains a phosphonic acid group as the anchoring moiety and a charge-trapping core group flanked between two alkyl chain spacers as the charge trapping site. The memory characteristics strongly depend on the monolayer used due to the localized charge-trapping capability for different core groups, including the diacetylenic (DA) unit as the hole carrier trap, the naphthalenetetracarboxyldiimide (ND) unit as the electron carrier trap, and the one with both DA and ND units present, respectively. The device with the monolayer carrying both DA and ND groups has a larger memory window than that for the one containing DA only and a longer retention time than that for the one containing DA or ND only, giving a memory window of 1.4 V and a retention time around 10(9) s. This device with hybrid organic monolayer/inorganic dielectrics also exhibited rather stable device characteristics upon bending of the polymeric substrate.
Changing patterns in the use, recycling, and material substitution of mercury in the United States
Wilburn, David R.
2013-01-01
Environmental concerns have led to numerous regulations that have dramatically decreased the reported production and use of mercury in the United States since the 1980s. Government legislation and subsequent industry actions have led to increased collection of mercury-containing materials and the recovery of mercury through recycling. Mercury emissions have been reduced and effective alternatives to mercury products have been developed for many applications. This study updates and quantifies the changes in demand, supply, use, and material flow for mercury in various sectors in the United States that have taken place since 1996. Nearly all primary mercury produced in the United States is derived as a byproduct of processing of gold and silver ore in Nevada. Since 2001, annual production of mercury from gold and silver mining in Nevada has decreased by 22 percent overall because ore from greater depths containing low grade mercury is recovered, and mercury emissions from this source have decreased by 95 percent as a result of increased regulation and improved collection and suppression technology. The distribution of consumption of mercury in the United States has changed as a result of regulation (elimination of large-scale mercury use in the paint and battery sectors), reduction by consumers (decommissioning of mercury-cell chloralkali manufacturing capacity), and technological advances (improvements in dental, lighting, and wiring sectors). Mercury use in the chloralkali sector, the leading end-use sector in the United States in 1996, has declined by 98 percent from 136 metric tons (t) in 1996 to about 0.3 t in 2010 because of increased processing and recycling efficiencies and plant closures or conversion to other technologies. As plants were closed, mercury recovered from the infrastructure of decommissioned plants has been exported, making the United States a net exporter of mercury, even though no mercury has been produced as the primary product from mines in the United States since 1992. In 1996, the three leading end-use sectors for mercury in the United States were chloralkali manufacturing (accounting for 38 percent of consumption), electrical and electronic instrumentation (13 percent of consumption), and instruments and measuring devices (11 percent of consumption). In 2010, the three leading end-use sectors were dental amalgam (accounting for between 35 and 57 percent of consumption), electrical and electronic instrumentation (29 percent of consumption), and batteries (8 percent of consumption). Mercury use in lighting is increasing because incandescent lights are being phased out in favor of mercury-containing compact fluorescent bulbs, but the demand for mercury per unit produced is small. Dental amalgam constituted the largest amount of mercury in use in the United States. One study reported about 290 t of mercury in dental amalgam was estimated to be contained in human mouths, an estimated 30 t of mercury amalgam was treated as waste, 28.5 t of mercury amalgam was released to the environment, 6 t of amalgam was recycled, and 3.5 t was treated and stored in landfills in 2009. Mercury contained in products recovered by State, municipal, or industry collection activities is recycled, but the estimated overall recycling rate is less than 10 percent. Increasingly, the U.S. mercury recycling industry has been processing a significant amount of mercury-containing material derived from foreign gold mining operations or decommissioned mercury-cell chloralkali plants. Regulation of mercury export and storage is expected to result in surplus mercury inventories in the United States. The Mercury Export Ban Act of 2008 limits elemental mercury exports for unregulated uses such as artisanal gold mining after January 1, 2013, and requires development of adequate long-term storage facilities in the United States for elemental mercury. During the past 4 years, producers and recyclers of elemental mercury have been exporting large quantities of mercury in anticipation of this regulation, but the U.S. inventory of mercury in 2010 was estimated to have exceeded 7,000 t from Government stockpiles and industry stocks. Costs attributed to long-term storage may affect the competitiveness of mercury recycling.
Romero, C; Abdallh, M E; Powers, W; Angel, R; Applegate, T J
2012-05-01
Effects of dietary adipic acid (0 vs. 1%) and corn dried distillers grains with solubles (DDGS; 0 vs. 20%) were evaluated on hen performance and egg characteristics from 26 to 34 wk of age. Four isocaloric and isonitrogenous diets were randomly assigned to blocks of 6 consecutive cages (36 cages per diet; 2 hens per cage). On wk 2 and 7 of the experiment, excreta were collected by cage block, mixed, and equally split into 2 containers. Sodium bisulfate (SBS) was spread (8.8 kg/100 m(2)) on the top surface of half of the containers. All containers were stored uncovered for 14 d at room temperature. Excreta pH, DM, and N content were measured on d 0, 7, and 14 of storage. Feed intake (112 g/d per hen), egg production (96.1%), and egg specific gravity (1.079 g/g) were not affected by diet. On excreta collection day, a synergy (P = 0.014) between dietary adipic acid and DDGS was detected, as the lowest excreta pH was obtained with the diet including both adipic acid and DDGS. On d 7 of storage, excreta pH was still reduced by dietary adipic acid (P = 0.046) and DDGS (P < 0.001), but a week later, only dietary DDGS decreased excreta pH (8.91 vs. 9.21; P < 0.001). Whereas dietary adipic acid had no influence on excreta N loss, excreta from hens fed 20% DDGS lost 19.7% more N (P = 0.039) during storage than hens not eating DDGS. Surface amendment of excreta with SBS increased excreta DM content, with the effect being even more marked on d 14 of storage (increase of 6.7 percentage units; P < 0.001), consistently decreased excreta pH during storage (P < 0.001) and reduced N loss by 26.1% for the 14 d of storage period.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hladek, K.L.
1997-10-07
The 618-11 (Wye or 318-11) burial ground received transuranic (TRTJ) and mixed fission solid waste from March 9, 1962, through October 2, 1962. It was then closed for 11 months so additional burial facilities could be added. The burial ground was reopened on September 16, 1963, and continued operating until it was closed permanently on December 31, 1967. The burial ground received wastes from all of the 300 Area radioactive material handling facilities. The purpose of this document is to characterize the 618-11 solid waste burial ground by describing the site, burial practices, the disposed wastes, and the waste generatingmore » facilities. This document provides information showing that kilogram quantities of plutonium were disposed to the drum storage units and caissons, making them transuranic (TRU). Also, kilogram quantities of plutonium and other TRU wastes were disposed to the three trenches, which were previously thought to contain non-TRU wastes. The site burial facilities (trenches, caissons, and drum storage units) should be classified as TRU and the site plutonium inventory maintained at five kilograms. Other fissile wastes were also disposed to the site. Additionally, thousands of curies of mixed fission products were also disposed to the trenches, caissons, and drum storage units. Most of the fission products have decayed over several half-lives, and are at more tolerable levels. Of greater concern, because of their release potential, are TRU radionuclides, Pu-238, Pu-240, and Np-237. TRU radionuclides also included slightly enriched 0.95 and 1.25% U-231 from N-Reactor fuel, which add to the fissile content. The 618-11 burial ground is located approximately 100 meters due west of Washington Nuclear Plant No. 2. The burial ground consists of three trenches, approximately 900 feet long, 25 feet deep, and 50 feet wide, running east-west. The trenches constitute 75% of the site area. There are 50 drum storage units (five 55-gallon steel drums welded together) buried in three rows in the northeast comer. In addition, five eight-foot diameter caissons are located at the west end of the center row of the drum storage units. Initially, wastes disposed to the caissons and drum storage units were from the 325 and 327 building hot cells. Later, a small amount of remote-handled (RH) waste from the 309 building Plutonium Recycle Test Reactor (PRTR) cells, and the newly built 324 building hot cells, was disposed at the site.« less
Hydrogen storage capacity on Ti-decorated porous graphene: First-principles investigation
NASA Astrophysics Data System (ADS)
Yuan, Lihua; Kang, Long; Chen, Yuhong; Wang, Daobin; Gong, Jijun; Wang, Chunni; Zhang, Meiling; Wu, Xiaojuan
2018-03-01
Hydrogen storage capacity on Titanium (Ti) decorated porous graphene (PG) has been investigated using density functional theory simulations with generalized gradient approximation method. The possible adsorption sites of Ti atom on PG and electronic properties of Ti-PG system are also discussed.The results show a Ti atom prefers to strongly adsorb on the center site above the C hexagon with the binding energy of 3.65 eV, and the polarization and the hybridization mechanisms both contribute to the Ti atom adsorption on PG. To avoid a tendency of clustering among Ti atoms, the single side of the PG unit cell should only contain one Ti atom. For the single side of PG, four H2 molecules can be adsorbed around Ti atom, and the adsorption mechanism of H2 molecules come from not only the polarization mechanism between Ti and H atoms but also the orbital hybridization among Ti atom, H2 molecules and C atoms. For the case of double sides of PG, eight H2 molecules can be adsorbed on Ti-decorated PG unit cell with the average adsorption energy of -0.457 eV, and the gravimetric hydrogen storage capacity is 6.11 wt.%. Furthermore, ab inito molecular-dynaics simulation result shows that six H2 molecules can be adsorbed on double sides of unit cell of Ti-PG system and the configuration of Ti-PG is very stable at 300 K and without external pressure, which indicates Ti-decorated PG could be considered as a potential hydrogen storage medium at ambient conditions.
Battery management system with distributed wireless sensors
Farmer, Joseph C.; Bandhauer, Todd M.
2016-02-23
A system for monitoring parameters of an energy storage system having a multiplicity of individual energy storage cells. A radio frequency identification and sensor unit is connected to each of the individual energy storage cells. The radio frequency identification and sensor unit operates to sense the parameter of each individual energy storage cell and provides radio frequency transmission of the parameters of each individual energy storage cell. A management system monitors the radio frequency transmissions from the radio frequency identification and sensor units for monitoring the parameters of the energy storage system.
Method for encryption and transmission of digital keying data
Mniszewski, Susan M.; Springer, Edward A.; Brenner, David P.
1988-01-01
A method for the encryption, transmission, and subsequent decryption of digital keying data. The method utilizes the Data Encryption Standard and is implemented by means of a pair of apparatus, each of which is selectable to operate as either a master unit or remote unit. Each unit contains a set of key encryption keys which are indexed by a common indexing system. The master unit operates upon command from the remote unit to generate a data encryption key and encrypt the data encryption key using a preselected key encryption key. The encrypted data encryption key and an index designator are then downloaded to the remote unit, where the data encryption key is decrypted for subsequent use in the encryption and transmission data. Downloading of the encrypted data encryption key enables frequent change of keys without requiring manual entry or storage of keys at the remote unit.
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
Storage of breast milk: effect of temperature and storage duration on microbial growth.
Igumbor, E O; Mukura, R D; Makandiramba, B; Chihota, V
2000-09-01
To study the effect of storage duration at varying temperature ranges, the pattern of microbial isolates and the quantity of colony-forming units (CFU) on expressed breast milk. Cross sectional study. Bacteriology laboratory, University of Zimbabwe in Parirenyatwa Hospital, Harare. The temperature, storage duration and types of micro-organisms in freshly expressed breast milk. Freshly expressed human breast milk contained microbial non-pathogens of skin flora. There was no growth of organisms in stored breast milk after four hours, eight hours, 24 hours and 72 hours storage duration at temperature ranges 0 to 4 degrees C (freezing temperature), 4 to 10 degrees C (refrigerator temperature), 15 to 27 degrees C (room temperature) and 30 to 38 degrees C (high temperature) respectively. Growth was detected after the storage durations and organisms isolated were both pathogens and non-pathogens with low counts. Average colony counts was (CFU < 200). The study revealed that storage duration for expressed breast milk should not exceed 24 hours in refrigerator temperature (4 to 10 degrees C), eight hours at room temperature (15 to 27 degrees C) and four hours at high temperature (30 to 38 degrees C). Although freezing temperature (0 to 4 degrees C) seemed safest for breast milk storage, short-term storage in a freezer is not recommended due to likely the hazards of the thawing process.
Distributed trace using central performance counter memory
Satterfield, David L; Sexton, James C
2013-10-22
A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.
Distributed trace using central performance counter memory
Satterfield, David L.; Sexton, James C.
2013-01-22
A plurality of processing cores, are central storage unit having at least memory connected in a daisy chain manner, forming a daisy chain ring layout on an integrated chip. At least one of the plurality of processing cores places trace data on the daisy chain connection for transmitting the trace data to the central storage unit, and the central storage unit detects the trace data and stores the trace data in the memory co-located in with the central storage unit.
Hydrogen storage and integrated fuel cell assembly
Gross, Karl J.
2010-08-24
Hydrogen is stored in materials that absorb and desorb hydrogen with temperature dependent rates. A housing is provided that allows for the storage of one or more types of hydrogen-storage materials in close thermal proximity to a fuel cell stack. This arrangement, which includes alternating fuel cell stack and hydrogen-storage units, allows for close thermal matching of the hydrogen storage material and the fuel cell stack. Also, the present invention allows for tailoring of the hydrogen delivery by mixing different materials in one unit. Thermal insulation alternatively allows for a highly efficient unit. Individual power modules including one fuel cell stack surrounded by a pair of hydrogen-storage units allows for distribution of power throughout a vehicle or other electric power consuming devices.
Analysis of the Effects of Sea Disposal on a One-Ton Container
NASA Technical Reports Server (NTRS)
Jackson, Wde C.; Jackson, Karen E.; Fasanella, Edwin L.; Kelley, John
2007-01-01
Excess and obsolete stocks of chemical warfare material (CWM) were sea disposed by the United States between 1919 and 1970. One-ton containers were used for bulk storage of CWM and were the largest containers sea disposed. Disposal depths ranged from 300 to 17,000 feet. Based on a Type D container assembly drawing, three independent analyses (one corrosion and two structural) were performed on the containers to address the corrosion resistance from prolonged exposure to sea water and the structural response during the descent. Corrosion predictions were made using information about corrosion rates and the disposal environment. The structural analyses employed two different finite element codes and were used to predict the buckling and material response of the container during sea disposal. The results of these investigations are summarized below. Detailed reports on each study are contained in the appendices.
NASA Astrophysics Data System (ADS)
Sakitani, Katsumi; Honda, Hiroshi
Experiments were performed to investigate feasibility of using organic materials as a PCM for a latent heat storage unit of a natural circulation cooling/latent heat storage system. This system was designed to cool a shelter accommodating telecommunication equipment located in subtropical deserts or similar regions without using a power source. Taking into account practical considerations and the results of various experiments regarding the thermodynamic properties, thermal degradation, and corrosiveness to metals, lauric acid and iron was selected for the PCM and the latent heat storage unit material, respectively. Cyclic heating and cooling of the latent heat storage unit undergoing solid-liquid phase change was repeated for more than 430 days. The results showed that the heating-cooling curve was almost unchanged between the early stage and the 1,870th cycle. It was concluded that the latent heat storage unit could be used safely for more than ten years as a component of the cooling system.
Storage peak gas-turbine power unit
NASA Technical Reports Server (NTRS)
Tsinkotski, B.
1980-01-01
A storage gas-turbine power plant using a two-cylinder compressor with intermediate cooling is studied. On the basis of measured characteristics of a .25 Mw compressor computer calculations of the parameters of the loading process of a constant capacity storage unit (05.3 million cu m) were carried out. The required compressor power as a function of time with and without final cooling was computed. Parameters of maximum loading and discharging of the storage unit were calculated, and it was found that for the complete loading of a fully unloaded storage unit, a capacity of 1 to 1.5 million cubic meters is required, depending on the final cooling.
NASA Astrophysics Data System (ADS)
Yuan, Bo; Zong, Jin; Xu, Zhicheng
2018-06-01
According to different operating characteristics of pumped storage fixed speed unit and variable speed unit, a joint dispatching model of pumped storage unit and other types of units based on mixed integer linear optimization is constructed. The model takes into account the operating conditions, reservoir capacity, cycle type and other pumped storage unit constraints, but also consider the frequent start and stop and the stability of the operation of the unit caused by the loss. Using the Cplex solver to solve the model, the empirical example of the provincial power grid shows that the model can effectively arrange the pumping storage speed and the dispatching operation of the variable speed unit under the precondition of economic life of the unit, and give full play to the function of peak shaving and accommodating new energy. Because of its more flexible regulation characteristics of power generation and pumping conditions, the variable speed unit can better improve the operating conditions of other units in the system and promote the new energy dissipation.
An explosively driven high-power microwave pulsed power system.
Elsayed, M A; Neuber, A A; Dickens, J C; Walter, J W; Kristiansen, M; Altgilbers, L L
2012-02-01
The increased popularity of high power microwave systems and the various sources to drive them is the motivation behind the work to be presented. A stand-alone, self-contained explosively driven high power microwave pulsed power system has been designed, built, and tested at Texas Tech University's Center for Pulsed Power and Power Electronics. The system integrates four different sub-units that are composed of a battery driven prime power source utilizing capacitive energy storage, a dual stage helical flux compression generator as the main energy amplification device, an integrated power conditioning system with inductive energy storage including a fast opening electro-explosive switch, and a triode reflex geometry virtual cathode oscillator as the microwave radiating source. This system has displayed a measured electrical source power level of over 5 GW and peak radiated microwaves of about 200 MW. It is contained within a 15 cm diameter housing and measures 2 m in length, giving a housing volume of slightly less than 39 l. The system and its sub-components have been extensively studied, both as integrated and individual units, to further expand on components behavior and operation physics. This report will serve as a detailed design overview of each of the four subcomponents and provide detailed analysis of the overall system performance and benchmarks.
An explosively driven high-power microwave pulsed power system
NASA Astrophysics Data System (ADS)
Elsayed, M. A.; Neuber, A. A.; Dickens, J. C.; Walter, J. W.; Kristiansen, M.; Altgilbers, L. L.
2012-02-01
The increased popularity of high power microwave systems and the various sources to drive them is the motivation behind the work to be presented. A stand-alone, self-contained explosively driven high power microwave pulsed power system has been designed, built, and tested at Texas Tech University's Center for Pulsed Power and Power Electronics. The system integrates four different sub-units that are composed of a battery driven prime power source utilizing capacitive energy storage, a dual stage helical flux compression generator as the main energy amplification device, an integrated power conditioning system with inductive energy storage including a fast opening electro-explosive switch, and a triode reflex geometry virtual cathode oscillator as the microwave radiating source. This system has displayed a measured electrical source power level of over 5 GW and peak radiated microwaves of about 200 MW. It is contained within a 15 cm diameter housing and measures 2 m in length, giving a housing volume of slightly less than 39 l. The system and its sub-components have been extensively studied, both as integrated and individual units, to further expand on components behavior and operation physics. This report will serve as a detailed design overview of each of the four subcomponents and provide detailed analysis of the overall system performance and benchmarks.
Radiation Heat Transfer Modeling Improved for Phase-Change, Thermal Energy Storage Systems
NASA Technical Reports Server (NTRS)
Kerslake, Thomas W.; Jacqmin, David A.
1998-01-01
Spacecraft solar dynamic power systems typically use high-temperature phase-change materials to efficiently store thermal energy for heat engine operation in orbital eclipse periods. Lithium fluoride salts are particularly well suited for this application because of their high heat of fusion, long-term stability, and appropriate melting point. Considerable attention has been focused on the development of thermal energy storage (TES) canisters that employ either pure lithium fluoride (LiF), with a melting point of 1121 K, or eutectic composition lithium-fluoride/calcium-difluoride (LiF-20CaF2), with a 1040 K melting point, as the phase-change material. Primary goals of TES canister development include maximizing the phase-change material melt fraction, minimizing the canister mass per unit of energy storage, and maximizing the phase-change material thermal charge/discharge rates within the limits posed by the container structure.
Role of Pumped Storage Hydro Resources in Electricity Markets and System Operation: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ela, E.; Kirby, B.; Botterud, A.
2013-05-01
The most common form of utility- sized energy storage system is the pumped storage hydro system. Originally, these types of storage systems were economically viable simply because they displace more expensive generating units. However, over time, as those expensive units became more efficient and costs declined, pumped hydro storage units no longer have the operational edge. As a result, in the current electricity market environment, pumped storage hydro plants are struggling. To offset this phenomenon, certain market modifications should be addressed. This paper will introduce some of the challenges faced by pumped storage hydro plants in today's markets and purposemore » some solutions to those problems.« less
100-D Ponds closure plan. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petersen, S.W.
1997-09-01
The 100-D Ponds is a Treatment, Storage, and Disposal (TSD) unit on the Hanford Facility that received both dangerous and nonregulated waste. This Closure Plan (Rev. 1) for the 100-D Ponds TSD unit consists of a RCRA Part A Dangerous Waste Permit Application (Rev. 3), a RCRA Closure Plan, and supporting information contained in the appendices to the plan. The closure plan consists of eight chapters containing facility description, process information, waste characteristics, and groundwater monitoring data. There are also chapters containing the closure strategy and performance standards. The strategy for the closure of the 100-D Ponds TSD unit ismore » clean closure. Appendices A and B of the closure plan demonstrate that soil and groundwater beneath 100-D Ponds are below cleanup limits. All dangerous wastes or dangerous waste constituents or residues associated with the operation of the ponds have been removed, therefore, human health and the environment are protected. Discharges to the 100-D Ponds, which are located in the 100-DR-1 operable unit, were discontinued in June 1994. Contaminated sediment was removed from the ponds in August 1996. Subsequent sampling and analysis demonstrated that there is no contamination remaining in the ponds, therefore, this closure plan is a demonstration of clean closure.« less
Crespo, Elena; Devasena, Samudrala; Sikkens, Cor; Centeno, Raymund; Cristescu, Simona M; Harren, Frans J M
2012-04-30
When performing trace gas analysis, it is not always possible to bring the source of volatiles and the gas analyzer together. In these cases, volatile storage containers, such as thermal desorption (TD) tubes, can be used for off-line measurement. TD is routinely combined with gas chromatography/mass spectrometry (GC/MS), but so far not with proton-transfer reaction mass spectrometry (PTRMS), which has a faster response. A PTR-quadrupole-MS instrument and a PTR-ion-trap-MS instrument were separately coupled to a TD unit for off-line analysis of trace volatiles in air. Carbograph 1TD/Carbopack X sorbent tubes were filled with different concentrations of a trace gas mixture containing low molecular weight volatiles (32 g/mol up to 136 g/mol) and measured with the above-mentioned combinations. The carrier gas in the TD unit was changed from helium to nitrogen to be able to combine this instrument with the mass spectrometer. Good linearity and reproducibility with the amount of gas stored were obtained. The storage capacity over time (up to 14 days) showed larger variability (<11% for all compounds, except for acetone 27%). Several tubes were filled with breath of different persons, and the breath of a smoker showed increased levels of acetonitrile and benzene. The combination of the PTR ion-trap instrument with the TD unit was also investigated. Due to its higher sampling rate, the ion-trap system showed higher throughput capabilities than the quadrupole system. The combination of TD with PTRMS using both a quadrupole and an ion trap for off-line volatile analysis has been validated. TD tubes can be a robust and compact volatile storage method when the mass spectrometry and the sampling cannot be performed in the same place, for example in large screening studies. In addition, a higher measurement throughput than with GC/MS could be obtained. Copyright © 2012 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Swenson, S. C.; Lawrence, D. M.
2014-12-01
Estimating the relative contributions of human withdrawals and climate variability to changes in groundwater is a challenging task at present. One method that has been used recently is a model-data synthesis combining GRACE total water storage estimates with simulated water storage estimates from land surface models. In this method, water storage changes due to natural climate variations simulated by a model are removed from total water storage changes observed by GRACE; the residual is then interpreted as anthropogenic groundwater change. If the modeled water storage estimate contains systematic errors, these errors will also be present in the residual groundwater estimate. For example, simulations performed with the Community Land Model (CLM; the land component of the Community Earth System Model) generally show a weak (as much as 50% smaller) seasonal cycle of water storage in semi-arid regions when compared to GRACE satellite water storage estimates. This bias propagates into GRACE-CLM anthropogenic groundwater change estimates, which then exhibit unphysical seasonal variability. The CLM bias can be traced to the parameterization of soil evaporative resistance. Incorporating a new soil resistance parameterization in CLM greatly reduces the seasonal bias with respect to GRACE. In this study, we compare the improved CLM water storage estimates to GRACE and discuss the implications for estimates of anthropogenic groundwater withdrawal, showing examples for the Middle East and Southwestern United States.
Evaporative cooling enhanced cold storage system
Carr, Peter
1991-01-01
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.
Evaporative cooling enhanced cold storage system
Carr, P.
1991-10-15
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.
VOCs Emissions from Multiple Wood Pellet Types and Concentrations in Indoor Air
Soto-Garcia, Lydia; Ashley, William J.; Bregg, Sandar; Walier, Drew; LeBouf, Ryan; Hopke, Philip K.; Rossner, Alan
2016-01-01
Wood pellet storage safety is an important aspect for implementing woody biomass as a renewable energy source. When wood pellets are stored indoors in large quantities (tons) in poorly ventilated spaces in buildings, such as in basements, off-gassing of volatile organic compounds (VOCs) can significantly affect indoor air quality. To determine the emission rates and potential impact of VOC emissions, a series of laboratory and field measurements were conducted using softwood, hardwood, and blended wood pellets manufactured in New York. Evacuated canisters were used to collect air samples from the headspace of drums containing pellets and then in basements and pellet storage areas of homes and small businesses. Multiple peaks were identified during GC/MS and GC/FID analysis, and four primary VOCs were characterized and quantified: methanol, pentane, pentanal, and hexanal. Laboratory results show that total VOCs (TVOCs) concentrations for softwood (SW) were statistically (p < 0.02) higher than blended or hardwood (HW) (SW: 412 ± 25; blended: 203 ± 4; HW: 99 ± 8, ppb). The emission rate from HW was the fastest, followed by blended and SW, respectively. Emissions rates were found to range from 10−1 to 10−5 units, depending upon environmental factors. Field measurements resulted in airborne concentrations ranging from 67 ± 8 to 5000 ± 3000 ppb of TVOCs and 12 to 1500 ppb of aldehydes, with higher concentrations found in a basement with a large fabric bag storage unit after fresh pellet delivery and lower concentrations for aged pellets. These results suggest that large fabric bag storage units resulted in a substantial release of VOCs into the building air. Occupants of the buildings tested discussed concerns about odor and sensory irritation when new pellets were delivered. The sensory response was likely due to the aldehydes. PMID:27022205
Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems
NASA Technical Reports Server (NTRS)
Fischer, J. S.
1977-01-01
The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.
Brange, J; Havelund, S; Hougaard, P
1992-06-01
Formation of covalent, higher molecular weight transformation (HMWT) products during storage of insulin preparations at 4-45 degrees C was studied by size exclusion chromatography. The main products are covalent insulin dimers (CID), but in protamine-containing preparations the concurrent formation of covalent insulin-protamine (CIP) products takes place. At temperatures greater than or equal to 25 degrees C parallel or consecutive formation of covalent oligo- and polymers can also be observed. Rate of HMWT is only slightly influenced by species of insulin but varies with composition and formulation, and for isophane (NPH) preparations, also with the strength of preparation. Temperature has a pronounced effect on CID, CIP, and, especially, covalent oligo- and polymer formation. The CIDs are apparently formed between molecules within the hexameric unit common for all types of preparations and rate of formation is generally faster in glycerol-containing preparations. Compared with insulin hydrolysis reactions (see the preceding paper), HMWT is one order of magnitude slower, except for NPH preparations.
Burger, Patrick; Korsten, Herbert; De Korte, Dirk; Rombout, Eva; Van Bruggen, Robin; Verhoeven, Arthur J
2010-11-01
Current additive solutions (ASs) for red blood cells (RBCs) do not maintain constant 2,3-diphosphoglycerate (DPG) and adenosine triphosphate (ATP) levels during cold storage. We have previously shown that with a new AS called phosphate-adenine-glucose-guanosine-gluconate-mannitol (PAGGGM), both 2,3-DPG and ATP could be maintained throughout storage for 35 days. In this study, the mechanism underlying the effect of PAGGGM on RBC storage was studied in more detail. By using double-erythrocytapheresis units (leukoreduced), a direct comparison could be made between the current AS saline-adenine-glucose-mannitol (SAGM) and the experimental solution PAGGGM. During cold storage, several in vitro characteristics were analyzed. In agreement with our previous findings with single RBCs, PAGGGM maintained 2,3-DPG and ATP levels for 35 days of cold storage. Furthermore, glucose consumption and lactate production were higher in PAGGGM units during the first 21 days of cold storage. Fructose-1,6-diphophate and dihydroxyacetone phosphate levels were also increased during the first 21 days of storage in PAGGGM units. These results indicate that it is likely that phosphofructokinase (PFK) activity is enhanced in PAGGGM units relative to SAGM units. After 21 days, PFK activity also decreases in PAGGGM units, but sufficient metabolic reserve in these units prevents depletion of 2,3-DPG and ATP. © 2010 American Association of Blood Banks.
24 CFR 3286.11 - Temporary storage of units.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...
24 CFR 3286.11 - Temporary storage of units.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...
24 CFR 3286.11 - Temporary storage of units.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Temporary storage of units. 3286.11 Section 3286.11 Housing and Urban Development Regulations Relating to Housing and Urban Development... Requirements § 3286.11 Temporary storage of units. Pursuant to § 3286.5(c), the manufacturer is required to...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The... 7 Agriculture 14 2010-01-01 2009-01-01 true Real property containing underground storage tanks... Property § 1955.57 Real property containing underground storage tanks. Within 30 days of acquisition of...
Code of Federal Regulations, 2010 CFR
2010-01-01
... shipping or storage of raw or processed agricultural products labeled as â100 percent organic,â âorganic,â... containers used for only shipping or storage of raw or processed agricultural products labeled as “100...) Nonretail containers used only to ship or store raw or processed agricultural product labeled as containing...
Code of Federal Regulations, 2011 CFR
2011-01-01
... shipping or storage of raw or processed agricultural products labeled as â100 percent organic,â âorganic,â... containers used for only shipping or storage of raw or processed agricultural products labeled as “100...) Nonretail containers used only to ship or store raw or processed agricultural product labeled as containing...
27 CFR 25.36 - Empty container storage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Empty container storage. 25.36 Section 25.36 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Construction and Equipment Equipment § 25.36 Empty container storage...
27 CFR 25.36 - Empty container storage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Empty container storage. 25.36 Section 25.36 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Construction and Equipment Equipment § 25.36 Empty container storage...
27 CFR 25.36 - Empty container storage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Empty container storage. 25.36 Section 25.36 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Construction and Equipment Equipment § 25.36 Empty container storage...
27 CFR 25.36 - Empty container storage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Empty container storage. 25.36 Section 25.36 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Construction and Equipment Equipment § 25.36 Empty container storage...
National Assessment of Geologic Carbon Dioxide Storage Resources -- Trends and Interpretations
NASA Astrophysics Data System (ADS)
Buursink, M. L.; Blondes, M. S.; Brennan, S.; Drake, R., II; Merrill, M. D.; Roberts-Ashby, T. L.; Slucher, E. R.; Warwick, P.
2013-12-01
In 2012, the U.S. Geological Survey (USGS) completed an assessment of the technically accessible storage resource (TASR) for carbon dioxide (CO2) in geologic formations underlying the onshore and State waters area of the United States. The formations assessed are at least 3,000 feet (914 meters) below the ground surface. The TASR is an estimate of the CO2 storage resource that may be available for CO2 injection and storage that is based on present-day geologic and hydrologic knowledge of the subsurface and current engineering practices. Individual storage assessment units (SAUs) for 36 basins or study areas were defined on the basis of geologic and hydrologic characteristics outlined in the USGS assessment methodology. The mean national TASR is approximately 3,000 metric gigatons. To augment the release of the assessment, this study reviews input estimates and output results as a part of the resource calculation. Included in this study are a collection of both cross-plots and maps to demonstrate our trends and interpretations. Alongside the assessment, the input estimates were examined for consistency between SAUs and cross-plotted to verify expected trends, such as decreasing storage formation porosity with increasing SAU depth, for instance, and to show a positive correlation between storage formation porosity and permeability estimates. Following the assessment, the output results were examined for correlation with selected input estimates. For example, there exists a positive correlation between CO2 density and the TASR, and between storage formation porosity and the TASR, as expected. These correlations, in part, serve to verify our estimates for the geologic variables. The USGS assessment concluded that the Coastal Plains Region of the eastern and southeastern United States contains the largest storage resource. Within the Coastal Plains Region, the storage resources from the U.S. Gulf Coast study area represent 59 percent of the national CO2 storage capacity. As part of this follow up study, additional maps were generated to show the geographic distribution of the input estimates and the output results across the U.S. For example, the distribution of the SAUs with fresh, saline or mixed formation water quality is shown. Also mapped is the variation in CO2 density as related to basin location and to related properties such as subsurface temperature and pressure. Furthermore, variation in the estimated SAU depth and resulting TASR are shown across the assessment study areas, and these depend on the geologic basin size and filling history. Ultimately, multiple map displays are possible with the complete data set of input estimates and range of reported results. The findings from this study show the effectiveness of the USGS methodology and the robustness of the assessment.
Isolation of zymogen granules from rat pancreas.
Rindler, Michael J
2006-01-01
This unit describes methods for preparing zymogen granules from rat pancreas. Zymogen granules are storage organelles in pancreatic acinar cells containing digestive enzymes that are released into the pancreatic duct. The protocols in this unit take advantage of the large size (up to 1 microm diameter) and high density (>1.20 g/cm(3) on sucrose gradients) of the granules as compared to other cellular organelles. They use a combination of differential sedimentation and density gradient separation to accomplish the purification. Similar procedures can be used to isolate zymogen granules from mouse pancreas and canine pancreas. A protocol for preparing zymogen granules from dog pancreas is also included.
40 CFR 63.1360 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... process unit. If the greatest input to and/or output from a shared storage vessel is the same for two or... not have an intervening storage vessel. If two or more PAI process units have the same input to or... process unit that sends the most material to or receives the most material from the storage vessel. If two...
Collecting and recirculating condensate in a nuclear reactor containment
Schultz, Terry L.
1993-01-01
An arrangement passively cools a nuclear reactor in the event of an emergency, condensing and recycling vaporized cooling water. The reactor is surrounded by a containment structure and has a storage tank for cooling liquid, such as water, vented to the containment structure by a port. The storage tank preferably is located inside the containment structure and is thermally coupleable to the reactor, e.g. by a heat exchanger, such that water in the storage tank is boiled off to carry away heat energy. The water is released as a vapor (steam) and condenses on the cooler interior surfaces of the containment structure. The condensed water flows downwardly due to gravity and is collected and routed back to the storage tank. One or more gutters are disposed along the interior wall of the containment structure for collecting the condensate from the wall. Piping is provided for communicating the condensate from the gutters to the storage tank.
Collecting and recirculating condensate in a nuclear reactor containment
Schultz, T.L.
1993-10-19
An arrangement passively cools a nuclear reactor in the event of an emergency, condensing and recycling vaporized cooling water. The reactor is surrounded by a containment structure and has a storage tank for cooling liquid, such as water, vented to the containment structure by a port. The storage tank preferably is located inside the containment structure and is thermally coupleable to the reactor, e.g. by a heat exchanger, such that water in the storage tank is boiled off to carry away heat energy. The water is released as a vapor (steam) and condenses on the cooler interior surfaces of the containment structure. The condensed water flows downwardly due to gravity and is collected and routed back to the storage tank. One or more gutters are disposed along the interior wall of the containment structure for collecting the condensate from the wall. Piping is provided for communicating the condensate from the gutters to the storage tank. 3 figures.
Packaging of a large capacity magnetic bubble domain spacecraft recorder
NASA Technical Reports Server (NTRS)
Becker, F. J.; Stermer, R. L.
1977-01-01
A Solid State Spacecraft Data Recorder (SSDR), based on bubble domain technology, having a storage capacity of 10 to the 8th power bits, was designed and is being tested. The recorder consists of two memory modules each having 32 cells, each cell containing sixteen 100 kilobit serial bubble memory chips. The memory modules are interconnected to a Drive and Control Unit (DCU) module containing four microprocessors, 500 integrated circuits, a RAM core memory and two PROM's. The two memory modules and DCU are housed in individual machined aluminum frames, are stacked in brick fashion and through bolted to a base plate assembly which also houses the power supply.
System, methods and apparatus for program optimization for multi-threaded processor architectures
Bastoul, Cedric; Lethin, Richard A; Leung, Allen K; Meister, Benoit J; Szilagyi, Peter; Vasilache, Nicolas T; Wohlford, David E
2015-01-06
Methods, apparatus and computer software product for source code optimization are provided. In an exemplary embodiment, a first custom computing apparatus is used to optimize the execution of source code on a second computing apparatus. In this embodiment, the first custom computing apparatus contains a memory, a storage medium and at least one processor with at least one multi-stage execution unit. The second computing apparatus contains at least two multi-stage execution units that allow for parallel execution of tasks. The first custom computing apparatus optimizes the code for parallelism, locality of operations and contiguity of memory accesses on the second computing apparatus. This Abstract is provided for the sole purpose of complying with the Abstract requirement rules. This Abstract is submitted with the explicit understanding that it will not be used to interpret or to limit the scope or the meaning of the claims.
Solid state recording current meter conversion
Cheng, Ralph T.; Wang, Lichen
1985-01-01
The authors describe the conversion of an Endeco-174 current meter to a solid-state recording current meter. A removable solid-state module was designed to fit in the space originally occupied by an 8-track tape cartridge. The module contains a CPU and 128 kilobytes of nonvolatile CMOS memory. The solid-state module communicates with any terminal or computer using an RS-232C interface at 4800 baud rate. A primary consideration for conversion was to keep modifications of the current meter to a minimum. The communication protocol was designed to emulate the Endeco tape translation unit, thus the need for a translation unit was eliminated and the original data reduction programs can be used without any modification. After conversion, the data recording section of the current meter contains no moving parts; the storage capacity of the module is equivalent to that of the original tape cartridge.
Waste Encapsulation and Storage Facility (WESF) Dangerous Waste Training Plan (DWTP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
SIMMONS, F.M.
2000-03-29
This Waste Encapsulation Storage Facility (WESF) Dangerous Waste Training Plan (DWTP) applies to personnel who perform work at, or in support of WESF. The plan, along with the names of personnel, may be given to a regulatory agency inspector upon request. General workers, subcontractors, or visiting personnel who have not been trained in the management of dangerous wastes must be accompanied by an individual who meets the requirements of this training plan. Dangerous waste management includes handling, treatment, storage, and/or disposal of dangerous and/or mixed waste. Dangerous waste management units covered by this plan include: less-than-90-day accumulation area(s); pool cellsmore » 1-8 and 12 storage units; and process cells A-G storage units. This training plan describes general requirements, worker categories, and provides course descriptions for operation of the WESF permitted miscellaneous storage units and the Less-than-90-Day Accumulation Areas.« less
Effects of Storage Time on Glycolysis in Donated Human Blood Units
Qi, Zhen; Roback, John D.; Voit, Eberhard O.
2017-01-01
Background: Donated blood is typically stored before transfusions. During storage, the metabolism of red blood cells changes, possibly causing storage lesions. The changes are storage time dependent and exhibit donor-specific variations. It is necessary to uncover and characterize the responsible molecular mechanisms accounting for such biochemical changes, qualitatively and quantitatively; Study Design and Methods: Based on the integration of metabolic time series data, kinetic models, and a stoichiometric model of the glycolytic pathway, a customized inference method was developed and used to quantify the dynamic changes in glycolytic fluxes during the storage of donated blood units. The method provides a proof of principle for the feasibility of inferences regarding flux characteristics from metabolomics data; Results: Several glycolytic reaction steps change substantially during storage time and vary among different fluxes and donors. The quantification of these storage time effects, which are possibly irreversible, allows for predictions of the transfusion outcome of individual blood units; Conclusion: The improved mechanistic understanding of blood storage, obtained from this computational study, may aid the identification of blood units that age quickly or more slowly during storage, and may ultimately improve transfusion management in clinics. PMID:28353627
Effects of Storage Time on Glycolysis in Donated Human Blood Units.
Qi, Zhen; Roback, John D; Voit, Eberhard O
2017-03-29
Background : Donated blood is typically stored before transfusions. During storage, the metabolism of red blood cells changes, possibly causing storage lesions. The changes are storage time dependent and exhibit donor-specific variations. It is necessary to uncover and characterize the responsible molecular mechanisms accounting for such biochemical changes, qualitatively and quantitatively; Study Design and Methods : Based on the integration of metabolic time series data, kinetic models, and a stoichiometric model of the glycolytic pathway, a customized inference method was developed and used to quantify the dynamic changes in glycolytic fluxes during the storage of donated blood units. The method provides a proof of principle for the feasibility of inferences regarding flux characteristics from metabolomics data; Results : Several glycolytic reaction steps change substantially during storage time and vary among different fluxes and donors. The quantification of these storage time effects, which are possibly irreversible, allows for predictions of the transfusion outcome of individual blood units; Conclusion : The improved mechanistic understanding of blood storage, obtained from this computational study, may aid the identification of blood units that age quickly or more slowly during storage, and may ultimately improve transfusion management in clinics.
Additive solution-7 reduces the red blood cell cold storage lesion.
Cancelas, Jose A; Dumont, Larry J; Maes, Lou A; Rugg, Neeta; Herschel, Louise; Whitley, Pamela H; Szczepiokowski, Zbigniew M; Siegel, Alan H; Hess, John R; Zia, Majid
2015-03-01
Transfusion of long-stored red blood cells (RBCs) is associated with decreased in vivo RBC recovery, delivery of RBC breakdown products, and increased morbidity and mortality. Reducing the burden of this RBC "storage lesion" is a major challenge in transfusion medicine. Additive solution-7 (AS-7) is a new RBC storage solution designed to improve RBC metabolism by providing phosphate and increasing buffering capacity. Storage quality in AS-7 was measured in a prospective, randomized, three-center trial using units of whole blood from healthy human subjects whose RBCs were stored for up to 56 days in AS-7 (n = 120) or for 42 days in the control solution AS-1 (n = 60). Hemolysis and shedding of protein-containing microvesicles were significantly reduced in RBCs stored in AS-7 for 42 and 56 days compared with RBCs stored in AS-1. Autologous in vivo recoveries of RBCs stored in AS-7 was 88 ± 5% at 42 days (n = 27) and 82 ± 3% at 56 days (n = 27), exceeding recoveries of RBCs stored in currently used solutions. Increasing the phosphate, pH range, and buffer capacity of a RBC storage system allowed RBCs to be stored better and longer than currently approved storage systems. AS-7 ameliorates the long-term storage lesion resulting in significantly increased viability in vitro and in vivo. © 2014 AABB.
The trafficking pathway of a wheat storage protein in transgenic rice endosperm.
Oszvald, Maria; Tamas, Laszlo; Shewry, Peter R; Tosi, Paola
2014-04-01
The trafficking of proteins in the endoplasmic reticulum (ER) of plant cells is a topic of considerable interest since this organelle serves as an entry point for proteins destined for other organelles, as well as for the ER itself. In the current work, transgenic rice was used to study the pattern and pathway of deposition of the wheat high molecular weight (HMW) glutenin sub-unit (GS) 1Dx5 within the rice endosperm using specific antibodies to determine whether it is deposited in the same or different protein bodies from the rice storage proteins, and whether it is located in the same or separate phases within these. The protein distribution and the expression pattern of HMW sub-unit 1Dx5 in transgenic rice endosperm at different stages of development were determined using light and electron microscopy after labelling with antibodies. The use of HMW-GS-specific antibodies showed that sub-unit 1Dx5 was expressed mainly in the sub-aleurone cells of the endosperm and that it was deposited in both types of protein body present in the rice endosperm: derived from the ER and containing prolamins, and derived from the vacuole and containing glutelins. In addition, new types of protein bodies were also formed within the endosperm cells. The results suggest that the HMW 1Dx5 protein could be trafficked by either the ER or vacuolar pathway, possibly depending on the stage of development, and that its accumulation in the rice endosperm could compromise the structural integrity of protein bodies and their segregation into two distinct populations in the mature endosperm.
Nguyen, Le Anh P; Clements, Archie C A; Jeffery, Jason A L; Yen, Nguyen Thi; Nam, Vu Sinh; Vaughan, Gregory; Shinkfield, Ramon; Kutcher, Simon C; Gatton, Michelle L; Kay, Brian H; Ryan, Peter A
2011-06-01
Since 2000, the Government of Viet Nam has committed to provide rural communities with increased access to safe water through a variety of household water supply schemes (wells, ferrocement tanks and jars) and piped water schemes. One possible, unintended consequence of these schemes is the concomitant increase in water containers that may serve as habitats for dengue mosquito immatures, principally Aedes aegypti. To assess these possible impacts we undertook detailed household surveys of Ae. aegypti immatures, water storage containers and various socioeconomic factors in three rural communes in southern Viet Nam. Positive relationships between the numbers of household water storage containers and the prevalence and abundance of Ae. aegypti immatures were found. Overall, water storage containers accounted for 92-97% and 93-96% of the standing crops of III/IV instars and pupae, respectively. Interestingly, households with higher socioeconomic levels had significantly higher numbers of water storage containers and therefore greater risk of Ae. aegypti infestation. Even after provision of piped water to houses, householders continued to store water in containers and there was no observed decrease in water storage container abundance in these houses, compared to those that relied entirely on stored water. These findings highlight the householders' concerns about the limited availability of water and their strong behavoural patterns associated with storage of water. We conclude that household water storage container availability is a major risk factor for infestation with Ae. aegypti immatures, and that recent investment in rural water supply infrastructure are unlikely to mitigate this risk, at least in the short term.
Cryogenic reactant storage for lunar base regenerative fuel cells
NASA Technical Reports Server (NTRS)
Kohout, Lisa L.
1989-01-01
There are major advantages to be gained by integrating a cryogenic reactant storage system with a hydrogen-oxygen regenerative fuel cell (RFC) to provide on-site electrical power during the lunar night. Although applicable to any power system using hydrogen-oxygen RFC's for energy storage, cryogenic reactant storage offers a significant benefit whenever the sun/shade cycle and energy storage period approach hundreds of hours. For solar power installations on the moon, cryogenic reactant storage reduces overall specific mass and meteoroid vulnerability of the system. In addition, it offers synergistic benefits to on-site users, such as availability of primary fuel cell reactants for surface rover vehicles and cryogenic propellants for OTV's. The integration involves processing and storing the RFC reactant streams as cryogenic liquids rather than pressurized gases, so that reactant containment (tankage per unit mass of reactants) can be greatly reduced. Hydrogen-oxygen alkaline RFC's, GaAs photovoltaic (PV) arrays, and space cryogenic processing/refrigeration technologies are assumed to be available for the conceptual system design. Advantages are demonstrated by comparing the characteristics of two power system concepts: a conventional lunar surface PV/RFC power system using pressurized gas storage in SOA filament wound pressure vessels and, that same system with gas liquefaction and storage replacing the pressurized storage. Comparisons are made at 20 and 250 kWe. Although cryogenic storage adds a processing plant (drying and liquefaction) to the system plus 30 percent more solar array to provide processing power, the approximate order of magnitude reduction in tankage mass, confirmed by this analysis, results in a reduction in overall total system mass of approximately 50 percent.
SHIPMENT OF TWO DOE-STD-3013 CONTAINERS IN A 9977 TYPE B PACKAGE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abramczyk, G.; Bellamy, S.; Loftin, B.
2011-06-06
The 9977 is a certified Type B Packaging authorized to ship uranium and plutonium in metal and oxide forms. Historically, the standard container for these materials has been the DOE-STD-3013 which was specifically designed for the long term storage of plutonium bearing materials. The Department of Energy has used the 9975 Packaging containing a single 3013 container for the transportation and storage of these materials. In order to reduce container, shipping, and storage costs, the 9977 Packaging is being certified for transportation and storage of two 3013 containers. The challenges and risks of this content and the 9977s ability tomore » meet the Code of Federal Regulations for the transport of these materials are presented.« less
Mycorrhiza-mediated competition between plants and decomposers drives soil carbon storage.
Averill, Colin; Turner, Benjamin L; Finzi, Adrien C
2014-01-23
Soil contains more carbon than the atmosphere and vegetation combined. Understanding the mechanisms controlling the accumulation and stability of soil carbon is critical to predicting the Earth's future climate. Recent studies suggest that decomposition of soil organic matter is often limited by nitrogen availability to microbes and that plants, via their fungal symbionts, compete directly with free-living decomposers for nitrogen. Ectomycorrhizal and ericoid mycorrhizal (EEM) fungi produce nitrogen-degrading enzymes, allowing them greater access to organic nitrogen sources than arbuscular mycorrhizal (AM) fungi. This leads to the theoretical prediction that soil carbon storage is greater in ecosystems dominated by EEM fungi than in those dominated by AM fungi. Using global data sets, we show that soil in ecosystems dominated by EEM-associated plants contains 70% more carbon per unit nitrogen than soil in ecosystems dominated by AM-associated plants. The effect of mycorrhizal type on soil carbon is independent of, and of far larger consequence than, the effects of net primary production, temperature, precipitation and soil clay content. Hence the effect of mycorrhizal type on soil carbon content holds at the global scale. This finding links the functional traits of mycorrhizal fungi to carbon storage at ecosystem-to-global scales, suggesting that plant-decomposer competition for nutrients exerts a fundamental control over the terrestrial carbon cycle.
Shelving Maximizes Storage and Productivity.
ERIC Educational Resources Information Center
School Business Affairs, 1984
1984-01-01
Describes specialized units that increase storage capacity. One involves two stationary units at either end of a track, with three or more movable units and one aisle; the other is an inclined rack. (MLF)
Fabrication, test and demonstration of critical environment monitoring system
NASA Technical Reports Server (NTRS)
Heimendinger, K. W.
1972-01-01
Design and performance of an analytical system for the evaluation of certain environmental constituents in critical environmental areas of the Quality Reliability and Assurance Laboratory are reported. Developed was a self-contained, integrated, minimum sized unit that detects, interrogates, and records those parameters of the environment dictated for control in large storage facilities, clean rooms, temporarily curtained enclosures, and special working benches. The system analyzes humidity, temperature, hydrocarbons particle size, and particle count within prescribed clean areas.
40 CFR 112.12 - Spill Prevention, Control, and Countermeasure Plan requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment failure or human error at the facility. (c) Bulk storage containers. (1) Not use a container for... means of containment for the entire capacity of the largest single container and sufficient freeboard to... soil conditions. (6) Bulk storage container inspections. (i) Except for containers that meet the...
40 CFR 112.12 - Spill Prevention, Control, and Countermeasure Plan requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment failure or human error at the facility. (c) Bulk storage containers. (1) Not use a container for... means of containment for the entire capacity of the largest single container and sufficient freeboard to... soil conditions. (6) Bulk storage container inspections. (i) Except for containers that meet the...
40 CFR 112.12 - Spill Prevention, Control, and Countermeasure Plan requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equipment failure or human error at the facility. (c) Bulk storage containers. (1) Not use a container for... means of containment for the entire capacity of the largest single container and sufficient freeboard to... soil conditions. (6) Bulk storage container inspections. (i) Except for containers that meet the...
Dencker, D; Pedersen, F; Engstrøm, T; Schroeder, T V; Lönn, L; Johansson, P I; De Backer, O
2017-08-01
To study the effect of red blood cell (RBC) storage duration on long-term mortality in patients undergoing cardiac intervention. RBCs undergo numerous structural and functional changes during storage. Observational studies have assessed the association between RBC storage duration and patient outcomes with conflicting results. Between January 2006 and December 2014, 82 408 patients underwent coronary angiography. Of these, 1856 patients received one to four RBC units within 30 days after this procedure. Patients were allocated according to length of RBC storage duration: short-term (≤11 days), intermediate (IM)-term (12-23 days) and long-term (≥24 days). The study endpoints were 30-day and long-term all-cause mortality. A total of 4168 RBC units were given to 1856 patients. The mean RBC storage duration was 8.5 ± 2.1, 17.7 ± 3.4 and 29.9 ± 3.4 days in the short-term, IM-term and long-term storage groups, respectively. There was no difference in baseline characteristics between the groups. The long-term storage group received significantly more units (2.4 ± 1.0 units) as compared to the short-term (2.0 ± 1.0 units; P < 0.001) and IM-term storage group (2.2 ± 1.0 units; P < 0.01). In the survival analysis, there was no significant difference in all-cause mortality between the groups (log-rank: 0.509 for 30-days mortality; 0.493 for 5-year mortality). Additional stratified analysis demonstrated no association between RBC storage duration and long-term mortality. This study did not find an association between RBC storage duration and 30-days or long-term mortality in patients undergoing cardiac intervention. © 2017 British Blood Transfusion Society.
Influence of Microstructure on the Fatigue Crack Growth of A516 in Hydrogen
NASA Technical Reports Server (NTRS)
Wachob, Harry F.; Nelson, Howard G.
1980-01-01
Some day hydrogen may be used as a viable energy storage and transport medium within the United States. Hydrogen gas may be used to dilute and extend our present methane supply as a blend or may even be used in its pure elemental form as a primary fuel. Independent of the methods of production, storage, and distribution, the interaction of hydrogen with its containment material will play an integral role in the success of a hydrogen energy program. Presently, the selection of hydrogen containment materials can be made such that the material will remain reasonably free from environmental degradation; however, costly alloying additions are required. Unfortunately, high alloy steels are economically prohibitive when large-scale hydrogen energy storage, transmission, and conversion systems are desired. Therefore, in order to implement such hydrogen energy systems in the future, existing low-cost materials must be improved via mechanical, thermal, or thermo-mechanical processing methods or new low-cost materials which are compatible with hydrogen must be developed. Originally, low strength, low alloy steels at room temperature were thought to be immune to hydrogen gas embrittlement, since no sustained load crack growth is observed. However, results of Clark in HY8O and Nelson in SAE 1020 have shown that the fatigue crack growth rate can be greatly accelerated in the presence of hydrogen gas. In recent results reported by Louthan and Mucci, the smooth bar fatigue life of an A1068 pipeline steel was reduced up to a factor of ten when the tests were performed in a 13.8 MPa hydrogen environment. These results suggest that the selection of material for structures designed to operate in hydrogen under cyclic loads must include consideration of hydrogen/metal fatigue interaction. Although the hydrogen/metal fatigue interaction can be severe in low strength low alloy steels, the degree of degradation may be altered by the underlying ferrous microstructure. At present, no correlation between microstructure and degree of hydrogen susceptibility exists for low strength steels. However, in high strength steels, susceptibility to hydrogen embrittlement has been shown to be strongly sensitive to the metallurgical microstructure. In addition, compositional effects and grain size can 703 Some day hydrogen may be used as a viable energy storage and transport medium within the United States. Hydrogen gas may be used to dilute and extend our present methane supply as a blend or may even be used in its pure elemental form as a primary fuel. Independent of the methods of production, storage, and distribution, the interaction of hydrogen with its containment material will play an integral role in the success of a hydrogen energy program. Presently, the selection of hydrogen containment materials can be made such that the material will remain reasonably free from environmental degradation; however, costly alloying additions are required. Unfortunately, high alloy steels are economically prohibitive when large-scale hydrogen energy storage, transmission, and conversion systems are desired. Therefore, in order to implement such hydrogen energy systems in the future, existing low-cost materials must be improved via mechanical, thermal, or thermo-mechanical processing methods or new low-cost materials which are compatible with hydrogen must be developed.
Fireproof impact limiter aggregate packaging inside shipping containers
Byington, Gerald A.; Oakes, Jr., Raymon Edgar; Feldman, Matthew Rookes
2001-01-01
The invention is a product and a process for making a fireproof, impact limiter, homogeneous aggregate material for casting inside a hazardous material shipping container, or a double-contained Type-B nuclear shipping container. The homogeneous aggregate material is prepared by mixing inorganic compounds with water, pouring the mixture into the void spaces between an inner storage containment vessel and an outer shipping container, vibrating the mixture inside the shipping container, with subsequent curing, baking, and cooling of the mixture to form a solidified material which encapsulates an inner storage containment vessel inside an outer shipping container. The solidified material forms a protective enclosure around an inner storage containment vessel which may store hazardous, toxic, or radioactive material. The solidified material forms a homogeneous fire-resistant material that does not readily transfer heat, and provides general shock and specific point-impact protection, providing protection to the interior storage containment vessel. The material is low cost, may contain neutron absorbing compounds, and is easily formed into a variety of shapes to fill the interior void spaces of shipping containers.
Xu, Dan; Sun, Lei; Li, Gang; Shang, Jin; Yang, Rui-Xia; Deng, Wei-Qiao
2016-06-01
Hydrogen storage is a primary challenge for using hydrogen as a fuel. With ideal hydrogen storage kinetics, the weak binding strength of hydrogen to sorbents is the key barrier to obtain decent hydrogen storage performance. Here, we reported the rational synthesis of a methyllithium-doped naphthyl-containing conjugated microporous polymer with exceptional binding strength of hydrogen to the polymer guided by theoretical simulations. Meanwhile, the experimental results showed that isosteric heat can reach up to 8.4 kJ mol(-1) and the methyllithium-doped naphthyl-containing conjugated microporous polymer exhibited an enhanced hydrogen storage performance with 150 % enhancement compared with its counterpart naphthyl-containing conjugated microporous polymer. These results indicate that this strategy provides a direction for design and synthesis of new materials that meet the US Department of Energy (DOE) hydrogen storage target. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The decision document, together with Records of Decision dated June 30, 1989 (PB90-114810) and September 20, 1988 (PB89-153837) and an Explanation of Significant Differences dated October 1991, present the selected remedial action for the Ninth Avenue Dump site. The remedial action for the site consists of two operable units. The first operable unit addressed an oil layer floating on the groundwater by means of oil and groundwater extraction, oil storage, reintroduction of the groundwater, containment with a slurry wall, and management of excess surface water. The extracted groundwater was treated prior to reintroduction. The second operable unit, which is beingmore » amended by this decision document, addresses the remaining threats at the site.« less
Spacecraft cryogenic gas storage systems
NASA Technical Reports Server (NTRS)
Rysavy, G.
1971-01-01
Cryogenic gas storage systems were developed for the liquid storage of oxygen, hydrogen, nitrogen, and helium. Cryogenic storage is attractive because of the high liquid density and low storage pressure of cryogens. This situation results in smaller container sizes, reduced container-strength levels, and lower tankage weights. The Gemini and Apollo spacecraft used cryogenic gas storage systems as standard spacecraft equipment. In addition to the Gemini and Apollo cryogenic gas storage systems, other systems were developed and tested in the course of advancing the state of the art. All of the cryogenic storage systems used, developed, and tested to date for manned-spacecraft applications are described.
Performance analysis of phase-change material storage unit for both heating and cooling of buildings
NASA Astrophysics Data System (ADS)
Waqas, Adeel; Ali, Majid; Ud Din, Zia
2017-04-01
Utilisation of solar energy and the night ambient (cool) temperatures are the passive ways of heating and cooling of buildings. Intermittent and time-dependent nature of these sources makes thermal energy storage vital for efficient and continuous operation of these heating and cooling techniques. Latent heat thermal energy storage by phase-change materials (PCMs) is preferred over other storage techniques due to its high-energy storage density and isothermal storage process. The current study was aimed to evaluate the performance of the air-based PCM storage unit utilising solar energy and cool ambient night temperatures for comfort heating and cooling of a building in dry-cold and dry-hot climates. The performance of the studied PCM storage unit was maximised when the melting point of the PCM was ∼29°C in summer and 21°C during winter season. The appropriate melting point was ∼27.5°C for all-the-year-round performance. At lower melting points than 27.5°C, declination in the cooling capacity of the storage unit was more profound as compared to the improvement in the heating capacity. Also, it was concluded that the melting point of the PCM that provided maximum cooling during summer season could be used for winter heating also but not vice versa.
U.S. Geological Survey Geologic Carbon Sequestration Assessment
NASA Astrophysics Data System (ADS)
Warwick, P. D.; Blondes, M. S.; Brennan, S.; Corum, M.; Merrill, M. D.
2012-12-01
The Energy Independence and Security Act of 2007 authorized the U.S. Geological Survey (USGS) to conduct a national assessment of potential geological storage resources for carbon dioxide (CO2) in consultation with the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and State geological surveys. To conduct the assessment, the USGS developed a probability-based assessment methodology that was extensively reviewed by experts from industry, government and university organizations (Brennan et al., 2010, http://pubs.usgs.gov/of/2010/1127). The methodology is intended to be used at regional to sub-basinal scales and it identifies storage assessment units (SAUs) that are based on two depth categories below the surface (1) 3,000 to 13,000 ft (914 to 3,962 m), and (2) 13,000 ft (3,962 m) and greater. In the first category, the 3,000 ft (914 m) minimum depth of the storage reservoir ensures that CO2 is in a supercritical state to minimize the storage volume. The depth of 13,000 ft (3,962 m) represents maximum depths that are accessible with average injection pressures. The second category represents areas where a reservoir formation has potential storage at depths below 13,000 ft (3,962 m), although they are not accessible with average injection pressures; these are assessed as a separate SAU. SAUs are restricted to formation intervals that contain saline waters (total dissolved solids greater than 10,000 parts per million) to prevent contamination of protected ground water. Carbon dioxide sequestration capacity is estimated for buoyant and residual storage traps within the basins. For buoyant traps, CO2 is held in place in porous formations by top and lateral seals. For residual traps, CO2 is contained in porous formations as individual droplets held within pores by capillary forces. Preliminary geologic models have been developed to estimate CO2 storage capacity in approximately 40 major sedimentary basins within the United States. More than 200 SAUs have been identified within these basins. The results of the assessment are estimates of the technically accessible storage resources based on present-day geological and engineering technology related to CO2 injection into geologic formations; therefore the assessment is not of total in-place resources. Summary geologic descriptions of the evaluated basins and SAUs will be prepared, along with the national assessment results. During the coming year, these results will be released as USGS publications available from http://energy.usgs.gov. In support of these assessment activities, CO2 sequestration related research science is being conducted by members of the project. Results of our research will contribute to current and future CO2 storage assessments conducted by the USGS and other organizations. Research topics include: (a) geochemistry of CO2 interactions with subsurface environments; (b) subsurface petrophysical rock properties in relation to CO2 injection; (c) enhanced oil recovery and the potential for CO2 storage; (d) storage of CO2 in unconventional reservoirs (coal, shale, and basalt); (e) statistical aggregation of assessment results; and (f) potential risks of induced seismicity.
Effect of containers on the quality of Chemlali olive oil during storage.
Gargouri, Boutheina; Zribi, Akram; Bouaziz, Mohamed
2015-04-01
This study is undertaken to determine the storage stability of Chemlali extra-virgin olive oil (EVOO) in different containers such as clear and dark glass bottles, polyethylene (PE) and tin containers. The different oil samples were stored under light at room temperature. Quality parameters monitored during a 6-month-storage period included: acidity, peroxide value (PV), spectrophotometric indices (K232 and K270), chlorophyll and carotene pigments, fatty acids and sterol compositions, total phenols, Rancimat induction time as well as sensory evaluation. Tin containers and dark glass bottles recorded the lowest oxidation values. In addition, oil packed in tin containers and dark glass bottles showed better physicochemical and organoleptic characteristics than that stored in clear glass bottles and PE containers. A significant decrease (p < 0.05) in the antioxidant contents (carotenes, chlorophylls and total phenols) was observed in the oil stored in the clear glass bottles and PE containers. Such results proved that the storage of oil in tin containers and dark glass bottles appeared most adequate, and showed a gradual loss of quality during storage, especially in PE containers and clear glass bottles. This study has shown that the best packaging materials for the commercial packing of Chemlali extra-virgin olive oil are tin containers and dark glass bottles.
Preparation and Storage of High-Titer Lactic Streptococcus Bacteriophages1
Nyiendo, J.; Seidler, Ramon J.; Sandine, W. E.; Elliker, P. R.
1974-01-01
Various techniques were employed for preparation of high-titer bacteriophage lysates of Streptococcus lactis, S. cremoris, and S. diacetilactis strains. Infection of a 4-h host culture in litmus milk at 30 C yielded the highest titers (2 × 109 to 4 × 1011 plaque-forming units/ml) for most phages. Host infection in lactose-containing broth produced similar virus numbers only when 0.1 M tris(hydroxymethyl)aminomethane buffer stabilized the pH. The pH at the time of infection as well as the inoculum phage titer were critical in obtaining high titers. Optimum conditions for infection in broth were coupled with a polyethylene glycol concentration procedure to routinely produce milligram quantities of phage from 1 liter of lysate. Neutralization of whey lysates, as a means of storage, offered no survival advantage over unneutralized samples. Storage of phage lysates in a 15% glycerol whey solution at -22 C yielded a high rate of survival in most cases, even with repeated freezing and thawing, over a period of 24 months. PMID:16349981
Reservoir Architecture Control on the Geometry of a CO2 Plume Using 4D Seismic, Sleipner Field.
NASA Astrophysics Data System (ADS)
Bitrus, Roy; Iacopini, David; Bond, Clare
2017-04-01
Time lapse seismic from the Sleipner field, Norwegian North Sea represents a unique database to understand the geometry of a saline aquifer, the Utsira Sand Formation, and its role in containing sequestered CO2. The heterogeneous high permeability Utsira Sand formation bounded by an overlying seal is surrounded by impermeable to semi-permeable intra-reservoir thin shale units that influence the migration of injected CO2. It is important to understand and verify the dynamics of injected CO2 plume migration as this ensures close to accurate predictions of the evolving and stable state of CO2 in storage projects. Previous detailed interpretation results of the thin shale units and permeability flow path chimneys within the Utsira Formation have been used in this research. The Utsira Cap rock, IUTS1 and IUTS1 (Intra-Utsira Shale Units) are the top three units that affect the containment and upward migration path of injected CO2. They are combined with seismic geobodies of the CO2 plume across time lapse data. Here, these seismic geobodies are created using 2 methods to delineate the 3D shape and the cubic volume occupancy of the CO2 plume within the reservoir. Method 1 employs the use of an envelope attribute volume, where samples are extracted from voxels that contain seismic trace amplitude values of injected CO2 across the 3D data. These extracted samples are then tracked throughout the target area and then classed and quantified as a CO2 geobodies. Method 2 applies the same concept; the only difference is the samples extracted from voxels are classed based on the proximity and connectivity of pre-defined amplitude values. Both methods employ the use of a Bayesian classifier which defines the probability density function used to categorise the extracted threshold values. Our result of the 3D geobody shapes are compared against the internal geometry of the reservoir which shows the influence of the cap rock and intra-reservoir thin shales on the CO2 plume acting as baffles and flow paths. The amount of injected CO2 is compared against the occupied volume of CO2 within the reservoir rock. Result values are plotted in graphs and they give an indication of the upper and lower end of reservoir volume occupied by injected supercritical CO2. These values are based on the porosity, permeability, density and temperature values of the rock volume, formation fluid and supercritical CO2. The results also show a decrease in effective rock volume occupied by CO2 reaching the Utsira top cap rock with increase in injected amounts of CO2. Our results indicate that the methods proposed can be applied to storage reservoirs in their early to mid-stages to help predict and understand the internal geometries of the reservoir unit and how they can affect the containment or upward migration flow of CO2. The CO2 volumetric measurement can also be used as a well-grounded assessment for future saline aquifer storage projects.
29 CFR 1926.153 - Liquefied petroleum gas (LP-Gas).
Code of Federal Regulations, 2013 CFR
2013-07-01
... temporary period not to exceed 6 months they need not have fire-resisting foundations or saddles but shall...) Dispensing. (1) Filling of fuel containers for trucks or motor vehicles from bulk storage containers shall be.... (2) Filling of portable containers or containers mounted on skids from storage containers shall be...
29 CFR 1926.153 - Liquefied petroleum gas (LP-Gas).
Code of Federal Regulations, 2012 CFR
2012-07-01
... temporary period not to exceed 6 months they need not have fire-resisting foundations or saddles but shall...) Dispensing. (1) Filling of fuel containers for trucks or motor vehicles from bulk storage containers shall be.... (2) Filling of portable containers or containers mounted on skids from storage containers shall be...
29 CFR 1926.153 - Liquefied petroleum gas (LP-Gas).
Code of Federal Regulations, 2011 CFR
2011-07-01
... temporary period not to exceed 6 months they need not have fire-resisting foundations or saddles but shall...) Dispensing. (1) Filling of fuel containers for trucks or motor vehicles from bulk storage containers shall be.... (2) Filling of portable containers or containers mounted on skids from storage containers shall be...
29 CFR 1926.153 - Liquefied petroleum gas (LP-Gas).
Code of Federal Regulations, 2014 CFR
2014-07-01
... temporary period not to exceed 6 months they need not have fire-resisting foundations or saddles but shall...) Dispensing. (1) Filling of fuel containers for trucks or motor vehicles from bulk storage containers shall be.... (2) Filling of portable containers or containers mounted on skids from storage containers shall be...
Lih thermal energy storage device
Olszewski, Mitchell; Morris, David G.
1994-01-01
A thermal energy storage device for use in a pulsed power supply to store waste heat produced in a high-power burst operation utilizes lithium hydride as the phase change thermal energy storage material. The device includes an outer container encapsulating the lithium hydride and an inner container supporting a hydrogen sorbing sponge material such as activated carbon. The inner container is in communication with the interior of the outer container to receive hydrogen dissociated from the lithium hydride at elevated temperatures.
Hanford facility dangerous waste permit application, PUREX storage tunnels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haas, C. R.
1997-09-08
The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to Part B permit application documentation submitted for individual, `operating` treatment, storage, and/or disposal units, such as the PUREX Storage Tunnels (this document, DOE/RL-90-24).
An Isotope-Powered Thermal Storage unit for space applications
NASA Technical Reports Server (NTRS)
Lisano, Michael E.; Rose, M. F.
1991-01-01
An Isotope-Powered Thermal Storage Unit (ITSU), that would store and utilize heat energy in a 'pulsed' fashion in space operations, is described. Properties of various radioisotopes are considered in conjunction with characteristics of thermal energy storage materials, to evaluate possible implementation of such a device. The utility of the unit is discussed in light of various space applications, including rocket propulsion, power generation, and spacecraft thermal management.
Energy Storage in a fuel cell with bipolar membranes burning acid and hydroxide
NASA Astrophysics Data System (ADS)
Emren, A. T.; Holmstrom, V. J. M.
1983-04-01
A battery is described, in which bipolar membranes are used to split water into acid and hydroxide. The liquids may be stored for an indefinite time, and energy may be recovered at room temperature. It is shown that the liquids are able to store about 400 kJ/litre, which roughly corresponds to pumping water up to an altitude of 40 km. Bipolar membranes of low area resistance have been made and tested. The area resistance appears to have been 2-3 ohm sq cm. A battery containing 7 unit cells has been constructed and tested. The maximum output voltage has been 1.8 V. The cost for enrgy storage is estimated to range from $0.1 to 2.5 per kWh depending on the mode of operation.
Wind power systems for individual applications. [electric power supplies for homes
NASA Technical Reports Server (NTRS)
Clews, H. M.
1973-01-01
A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.
de Korte, Dirk; Thibault, Louis; Handke, Wiebke; Harm, Sarah K; Morrison, Alex; Fitzpatrick, Aine; Marks, Denese C; Yi, Qi-Long; Acker, Jason P
2018-04-01
There are few studies investigating the effect of irradiation on red blood cells (RBCs) during storage. This study analyzed changes in in vitro quality of RBCs irradiated at several points during storage with the aim of providing evidence to support current maximum pre- and postirradiation storage limits. Each of seven participating centers produced four pools of 7 standard RBC units (SAGM, AS-3, or PAGGSM), which were then split back into 7 units. All units in a pool were from sex-matched blood donors. Every week during 6 weeks of refrigerated storage, 1 unit was irradiated, while 1 unit was not irradiated (control). Units were tested weekly for biochemical variables, morphology, and mechanical fragility. The earlier during storage that units were irradiated, the higher the hemolysis and K + at end of storage. Irrespective of the timing of irradiation, there was a rapid increase in extracellular K + , followed by a more gradual increase in hemolysis. ATP levels decreased faster in irradiated units and were reduced below accepted values if irradiated early. Irradiated female RBCs had an absolute lower hemolysis and K + level compared to male RBCs at all time points. The method of blood component manufacturing determined the absolute levels of hemolysis and potassium in irradiated and nonirradiated units, but did not influence the effect that timing of irradiation had on the in vitro quality characteristics. This study provides support for the current Council of Europe guidelines on the time limitations for the irradiation of RBCs. © 2017 AABB.
Surficial aquifer system in eastern Lee County, Florida
Boggess, D.H.; Watkins, F.A.
1986-01-01
The surficial aquifer system in eastern Lee County consists of an upper water bearing unit, which is generally unconfined, and a lower water bearing unit, which is confined and is the major source tapped by most wells. The top of the lower unit, which is of primary interest in this report, ranges in depth from 40 to 60 ft below land surface in the east-central part of the county to more than 120 ft in the southern part. In the extreme southern part of the county, a middle water bearing unit also contains water under artesian pressure. Recharge to the lower unit occurs primarily by leakage from the overlying saturated section through the confining beds. Water levels in the lower unit fluctuate similarly to those in the upper (unconfined) unit. Groundwater in the lower unit moves from areas of highest water level in the south part of Lehigh acres, northward toward the Caloosahatchee River, and toward the coast. The lower unit contains freshwater throughout much of its extent and is the source of public water supply at Lehigh Acres and Green Meadows where an average of about 3 mil gal/day was withdrawn in 1980. In several areas, the concentrations of chlorides and dissolved solids exceed drinking water standards. Yields of wells that tap the lower unit range from 10 to 1,100 gal/min. Transmissivities ranging from about 17,700 to 7,750 sq ft/day were determined for different areas of the unit. Storage coefficients range from 0.0001 to 0.0003. (Author 's abstract)
Nuclear waste storage container with metal matrix
Sump, Kenneth R.
1978-01-01
The invention relates to a storage container for high-level waste having a metal matrix for the high-level waste, thereby providing greater impact strength for the waste container and increasing heat transfer properties.
Smulders, F J M; Hiesberger, J; Hofbauer, P; Dögl, B; Dransfield, E
2006-09-01
Beef has a requirement for refrigerated storage up to 14 d to achieve adequate aging and a tender product. To achieve this aging with little spoilage and no surface drying, vacuum packaging is attractive, because it is inherently simple and offers a clear indication to the packer when the process has failed or there is risk of spoilage. However, there is increasing pressure on the meat industry to limit the use of packaging materials in view of their cost and the cost involved in their recovery and recycling. The purpose of this report was to evaluate an alternative storage system in containers using modified atmospheres at reduced pressure (approximately 25 kPa). The quality of the meat for both container- and vacuum-packed treatments was measured during chilled storage for up to 3 wk. Storage time had the most significant effect on quality characteristics, irrespective of the packaging method. Storage in containers under a 70%N2:30%CO2 gas mixture gave characteristics similar to beef stored under vacuum. Storage in containers under 100% CO2 produced less drip loss than under 70%N2:30%CO2, but generally container storage produced 3 times as much drip loss as vacuum packaging. Shear force of the LM was unaffected by the type of packaging, and at d 2 after slaughter (i.e., before the storage trial was begun), sarcomere lengths of muscles intended for container storage were similar to those destined for vacuum storage. During the packaging treatment, the comparison between the storage systems was always done within 1 animal using one carcass-half for container storage and the other half for vacuum packaging; all bulls were shackled from the left hindleg during bleeding. The majority of the muscles from the left sides had lower shear force values than those from the right sides at the earlier storage times (2 and 9 d after slaughter) but had similar values after longer storage (16 and 23 d after slaughter). This is the first report that shackling beef carcasses from the left side can result in more tender meat in the LM from that side. The increased tenderness in the LM from the shackled side probably resulted from an early decrease in pH and an increase in calpain activity after mechanical strain of the muscles on the shackled side. This effect of shackling should be taken into account when designing systematic comparisons of tenderness in beef.
Parametric design studies of toroidal magnetic energy storage units
NASA Astrophysics Data System (ADS)
Herring, J. Stephen
Superconducting magnetic energy storage (SMES) units have a number of advantages as storage devices. Electrical current is the input, output and stored medium, allowing for completely solid-state energy conversion. The magnets themselves have no moving parts. The round trip efficiency is higher than those for batteries, compressed air or pumped hydro. Output power can be very high, allowing complete discharge of the unit within a few seconds. Finally, the unit can be designed for a very large number of cycles, limited basically by fatigue in the structural components. A small systems code was written to produce and evaluate self-consistent designs for toroidal superconducting energy storage units. The units can use either low temperature or high temperature superconductors. The coils have D shape where the conductor and its stabilizer/structure is loaded only in tension and the centering forces are borne by a bucking cylinder. The coils are convectively cooled from a cryogenic reservoir in the bore of the coils. The coils are suspended in a cylindrical metal shell which protects the magnet during rail, automotive or shipboard use. It is important to note that the storage unit does not rely on its surroundings for structural support, other than normal gravity and inertial loads. Designs are presented for toroidal energy storage units produced by the systems code. A wide range of several parameters have been considered, resulting in units storing from 1 MJ to 72 GJ. Maximum fields range from 5 T to 20 T. The masses and volumes of the coils, bucking cylinder, coolant, insulation and outer shell are calculated. For unattended use, the allowable operating time using only the boiloff of the cryogenic fluid for refrigeration is calculated. For larger units, the coils were divided into modules suitable for normal truck or rail transport.
Unitized Regenerative Fuel Cell System Development
NASA Technical Reports Server (NTRS)
Burke, Kenneth A.
2003-01-01
Unitized Regenerative Fuel Cells (URFC) have recently been developed by several fuel cell manufacturers. These manufacturers have concentrated their efforts on the development of the cell stack technology itself, and have not up to this point devoted much effort to the design and development of the balance of plant. A fuel cell technology program at the Glenn Research Center (GRC) that has as its goal the definition and feasibility testing of the URFC system balance of plant. Besides testing the feasibility, the program also intends to minimize the system weight, volume, and parasitic power as its goal. The design concept currently being developed uses no pumps to circulate coolant or reactants, and minimizes the ancillary components to only the oxygen and hydrogen gas storage tanks, a water storage tank, a loop heat pipe to control the temperature and two pressure control devices to control the cell stack pressures during operation. The information contained in this paper describes the design and operational concepts employed in this concept. The paper also describes the NASA Glenn research program to develop this concept and test its feasibility.
Design of self-contained sensor for monitoring of deep-sea offshore platform
NASA Astrophysics Data System (ADS)
Song, Yang; Yu, Yan; Zhang, Chunwei; Dong, Weijie; Ou, Jinping
2013-04-01
Offshore platform, which is the base of the production and living in the sea, is the most important infrastructure for developing oil and gas resources. At present, there are almost 6500 offshore platforms servicing in the 53 countries' sea areas around the world, creating great wealth for the world. In general, offshore platforms may work for 20 years, however, offshore platforms are expensive, complex, bulky, and so many of them are on extended active duty. Because of offshore platforms servicing in the harsh marine environment for a long time, the marine environment have a great impact on the offshore platforms. Besides, with the impact and erosion of seawater, and material aging, the offshore platform is possible to be in unexpected situations when a badly sudden situation happens. Therefore, it is of great significance to monitor the marine environment and offshore platforms. The self-contained sensor for deep-sea offshore platform with its unique design, can not only effectively extend the working time of the sensor with the capability of converting vibration energy to electrical energy, but also simultaneously collect the data of acceleration, inclination, temperature and humidity of the deep sea, so that we can achieve the purpose of monitoring offshore platforms through analyzing the collected data. The self-contained sensor for monitoring of deep-sea offshore platform includes sensing unit, data collecting and storage unit, the energy supply unit. The sensing unit with multi-variables, consists of an accelerometer LIS344ALH, an inclinometer SCA103T and a temperature and humidity sensor SHT11; the data collecting and storage unit includes the MSP430 low-power MCU, large capacity memory, clock circuit and the communication interface, the communication interface includes USB interface, serial ports and wireless interface; in addition, the energy supply unit, converting vibration to electrical energy to power the overall system, includes the electromagnetic generator, voltage multiplier circuit and a super capacitor which can withstand virtually unlimited number of charge-discharge cycles. When the seawater impacts on offshore platforms to produce vibration, electromagnetic generator converts vibration to electrical energy, its output(~ 1 V 50 Hz AC) is stepped up and rectified by a voltage multiplier circuit, and the energy is stored in a super capacitor. It is controlled by the MSP430 that monitors the voltage level on the super capacitor. The super capacitor charges the Li-ion battery when the voltage on the super capacitor reaches a threshold, then the whole process of energy supply is completed. The self-contained sensor for deep-sea offshore platform has good application prospects and practical value with small size, low power, being easy to install, converting vibration energy to supply power and high detection accuracy.
40 CFR 75.64 - Quarterly reports.
Code of Federal Regulations, 2013 CFR
2013-07-01
... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...
40 CFR 75.64 - Quarterly reports.
Code of Federal Regulations, 2012 CFR
2012-07-01
... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...
40 CFR 75.64 - Quarterly reports.
Code of Federal Regulations, 2011 CFR
2011-07-01
... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...
40 CFR 75.64 - Quarterly reports.
Code of Federal Regulations, 2014 CFR
2014-07-01
... placed in long-term cold storage (as defined in § 72.2 of this chapter), quarterly reports are not... the unit). For units placed into long-term cold storage during a reporting quarter, the exemption from... long-term cold storage. For any provisionally-certified monitoring system, § 75.20(a)(3) shall apply...
Stored grain pack factors for wheat: comparison of three methods to field measurements
USDA-ARS?s Scientific Manuscript database
Storing grain in bulk storage units results in grain packing from overbearing pressure, which increases grain bulk density and storage-unit capacity. This study compared pack factors of hard red winter (HRW) wheat in vertical storage bins using different methods: the existing packing model (WPACKING...
LiH thermal energy storage device
Olszewski, M.; Morris, D.G.
1994-06-28
A thermal energy storage device for use in a pulsed power supply to store waste heat produced in a high-power burst operation utilizes lithium hydride as the phase change thermal energy storage material. The device includes an outer container encapsulating the lithium hydride and an inner container supporting a hydrogen sorbing sponge material such as activated carbon. The inner container is in communication with the interior of the outer container to receive hydrogen dissociated from the lithium hydride at elevated temperatures. 5 figures.
NASA Technical Reports Server (NTRS)
Johnson, B.; Cavanaugh, J.; Smith, J.; Esaias, W.
1988-01-01
The Ocean Data Acquisition System (ODAS) is a low cost instrument with potential commercial application. It is easily mounted on a small aircraft and flown over the coastal zone ocean to remotely measure sea surface temperature and three channels of ocean color information. From this data, chlorophyll levels can be derived for use by ocean scientists, fisheries, and environmental offices. Data can be transmitted to shipboard for real-time use with sea truth measurements, ocean productivity estimates and fishing fleet direction. The aircraft portion of the system has two primary instruments: an IR radiometer to measure sea surface temperature and a three channel visible spectro-radiometer for 460, 490, and 520 nm wavelength measurements from which chlorophyll concentration can be derived. The aircraft package contains a LORAN-C unit for aircraft location information, clock, on-board data processor and formatter, digital data storage, packet radio terminal controller, and radio transceiver for data transmission to a ship. The shipboard package contains a transceiver, packet terminal controller, data processing and storage capability, and printer. Both raw data and chlorophyll concentrations are available for real-time analysis.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Bulk storage containers. (1) Not use a container for the storage of oil unless its material and... of the largest single container and sufficient freeboard to contain precipitation. You must ensure... conditions. (6) Test or inspect each aboveground container for integrity on a regular schedule and whenever...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Bulk storage containers. (1) Not use a container for the storage of oil unless its material and... of the largest single container and sufficient freeboard to contain precipitation. You must ensure... conditions. (6) Test or inspect each aboveground container for integrity on a regular schedule and whenever...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Bulk storage containers. (1) Not use a container for the storage of oil unless its material and... of the largest single container and sufficient freeboard to contain precipitation. You must ensure... conditions. (6) Test or inspect each aboveground container for integrity on a regular schedule and whenever...
Meli, Athinoula; Hancock, Vicky; Doughty, Heidi; Smedley, Steve; Cardigan, Rebecca; Wiltshire, Michael
2018-02-01
Maritime medical capability may be compromised by blood resupply. Air-dropped red blood cells (RBCs) is a possible mitigation factor. This study set out to evaluate RBC storage variables after a simulated parachute air drop into the sea, as limited data exist. The air load construction for the air drop of blood was subject to static drop assessment to simulate a worst-case parachute drop scenario. One control and two test Golden Hour shipping containers were each packaged with 10 RBC units. The control box was not dropped; Test Boxes 1 and 2 were further reinforced with waterproof boxes and underwent a simulated air drop on Day 7 or Day 8 postdonation, respectively. One day after the drop and once a week thereafter until Day 43 of storage, RBCs from each box were sampled and tested for full blood counts, hemolysis, adenosine triphosphate, 2,3-diphosphoglycerate, pH, extracellular potassium, glucose, lactate, deformability, and RBC microvesicles. The packaging configuration completed the air drop with no water ingress or physical damage. All units met UK specifications for volume, hemoglobin, and hemolysis. There were no significant differences for any of the variables studied between RBCs in the control box compared to RBCs in Test Boxes 1 and 2 combined over storage. The test proved that the packaging solution and the impact of a maritime air drop as performed in this study, on Day 7 or Day 8 postdonation, did not affect the in vitro quality of RBCs in SAGM over storage for 35 days. © 2017 AABB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office
This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 214 under the Federal Facility Agreement and Consent Order. Located in Areas 5, 11, and 25 of the Nevada Test Site, CAU 214 consists of nine Corrective Action Sites (CASs): 05-99-01, Fallout Shelters; 11-22-03, Drum; 25-99-12, Fly Ash Storage; 25-23-01, Contaminated Materials; 25-23-19, Radioactive Material Storage; 25-99-18, Storage Area; 25-34-03, Motor Dr/Gr Assembly (Bunker); 25-34-04, Motor Dr/Gr Assembly (Bunker); and 25-34-05, Motormore » Dr/Gr Assembly (Bunker). These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). The suspected contaminants and critical analyte s for CAU 214 include oil (total petroleum hydrocarbons-diesel-range organics [TPH-DRO], polychlorinated biphenyls [PCBs]), pesticides (chlordane, heptachlor, 4,4-DDT), barium, cadmium, chronium, lubricants (TPH-DRO, TPH-gasoline-range organics [GRO]), and fly ash (arsenic). The land-use zones where CAU 214 CASs are located dictate that future land uses will be limited to nonresidential (i.e., industrial) activities. The results of this field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the corrective action decision document.« less
Brooks, Kriston P; Holladay, Jamelyn D; Simmons, Kevin L; Herling, Darrell R
2014-11-18
An on-board hydride storage system and process are described. The system includes a slurry storage system that includes a slurry reactor and a variable concentration slurry. In one preferred configuration, the storage system stores a slurry containing a hydride storage material in a carrier fluid at a first concentration of hydride solids. The slurry reactor receives the slurry containing a second concentration of the hydride storage material and releases hydrogen as a fuel to hydrogen-power devices and vehicles.
Accelerator-driven Transmutation of Waste
NASA Astrophysics Data System (ADS)
Venneri, Francesco
1998-04-01
Nuclear waste from commercial power plants contains large quantities of plutonium, other fissionable actinides, and long-lived fission products that are potential proliferation concerns and create challenges for the long-term storage. Different strategies for dealing with nuclear waste are being followed by various countries because of their geologic situations and their views on nuclear energy, reprocessing and non-proliferation. The current United States policy is to store unprocessed spent reactor fuel in a geologic repository. Other countries are opting for treatment of nuclear waste, including partial utilization of the fissile material contained in the spent fuel, prior to geologic storage. Long-term uncertainties are hampering the acceptability and eventual licensing of a geologic repository for nuclear spent fuel in the US, and driving up its cost. The greatest concerns are with the potential for radiation release and exposure from the spent fuel for tens of thousands of years and the possible diversion and use of the actinides contained in the waste for weapons construction. Taking advantage of the recent breakthroughs in accelerator technology and of the natural flexibility of subcritical systems, the Accelerator-driven Transmutation of Waste (ATW) concept offers the United States and other countries the possibility to greatly reduce plutonium, higher actinides and environmentally hazardous fission products from the waste stream destined for permanent storage. ATW does not eliminate the need for, but instead enhances the viability of permanent waste repositories. Far from being limited to waste destruction, the ATW concept also brings to the table new technologies that could be relevant for next-generation power producing reactors. In the ATW concept, spent fuel would be shipped to the ATW site where the plutonium, transuranics and selected long-lived fission products would be destroyed by fission or transmutation in their first and only pass through the facility, using an accelerator-driven subcritical burner cooled by liquid lead/bismuth and limited pyrochemical treatment of the spent fuel and residual waste. This approach contrasts with the present-day practices of aqueous reprocessing (Europe and Japan), in which high purity plutonium is produced and used in the fabrication of fresh mixed oxide fuel (MOX) that is shipped off-site for use in light water reactors.
Contribution of water vapor pressure to pressurization of plutonium dioxide storage containers
NASA Astrophysics Data System (ADS)
Veirs, D. Kirk; Morris, John S.; Spearing, Dane R.
2000-07-01
Pressurization of long-term storage containers filled with materials meeting the US DOE storage standard is of concern.1,2 For example, temperatures within storage containers packaged according to the standard and contained in 9975 shipping packages that are stored in full view of the sun can reach internal temperatures of 250 °C.3 Twenty five grams of water (0.5 wt.%) at 250 °C in the storage container with no other material present would result in a pressure of 412 psia, which is limited by the amount of water. The pressure due to the water can be substantially reduced due to interactions with the stored material. Studies of the adsorption of water by PuO2 and surface interactions of water with PuO2 show that adsorption of 0.5 wt.% of water is feasible under many conditions and probable under high humidity conditions.4,5,6 However, no data are available on the vapor pressure of water over plutonium dioxide containing materials that have been exposed to water.
Magnet design for a low-emittance storage ring
Johansson, Martin; Anderberg, Bengt; Lindgren, Lars-Johan
2014-01-01
The MAX IV 3 GeV storage ring, currently under construction, pursues the goal of low electron beam emittance by using a multi-bend achromat magnet lattice, which is realised by having several consecutive magnet elements precision-machined out of a common solid iron block, 2.3–3.4 m long. With this magnet design solution, instead of having 1320 individual magnets, the MAX IV 3 GeV storage ring is built up using 140 integrated ‘magnet block’ units, containing all these magnet elements. Major features of this magnet block design are compactness, vibration stability and that the alignment of magnet elements within each unit is given by the mechanical accuracy of the CNC machining rather than individual field measurement and adjustment. This article presents practical engineering details of implementing this magnet design solution, and mechanical + magnetic field measurement results from the magnet production series. At the time of writing (spring 2014), the production series, which is totally outsourced to industry, is roughly half way through, with mechanical/magnetic QA conforming to specifications. It is the conclusion of the authors that the MAX IV magnet block concept, which has sometimes been described as new or innovative, is from a manufacturing point of view simply a collection of known mature production methods and measurement procedures, which can be executed at fixed cost with a low level of risk. PMID:25177980
Hanford facility dangerous waste permit application, general information portion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, C.B.
1998-05-19
The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOE/RL-91-28) and a Unit-Specific Portion. Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the content of the Part B permit application guidance prepared by the Washington State Department of Ecology (Ecology 1996) and the U.S. Environmental Protection Agency (40 Code of Federal Regulations 270), with additional information needed by the Hazardous and Solid Waste Amendments and revisions of Washington Administrative Code 173-303. Documentation contained in the General Information Portion ismore » broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in this report).« less
Carver, D A; Ball, B A
2002-11-01
Previous studies have demonstrated a detrimental effect of seminal plasma on the maintenance of motility of cooled equine spermatozoa; however, the mechanism for the adverse effect of seminal plasma during cooled storage remains undetermined. In goats, a glycoprotein component of bulbourethral gland secretion contains lipase activity that is detrimental to sperm motility when stored in skim milk-based extenders. The objective of the current study was to determine the amount of lipase activity in stallion seminal plasma and to determine the effect of added lipase on spermatozoal motility during cooled semen storage. In the first experiment, seminal plasma (1.0 ml) was assayed for lipase activity based upon hydrolysis of triglycerides (olive oil substrate) into free fatty acids and subsequent titration of pH change (SigmaDiagnostic Lipase Kit). Lipase activity in stallion seminal plasma was 0.36 +/- 0.02 Sigma units/ml, (mean + S.E.M.; n = 16 ejaculates from six stallions). In the second experiment, equine semen (three ejaculates from each of four stallions) was divided into five treatment aliquots. In Treatment 1, semen was extended 1:3 with nonfat dried skim milk extender (NFDSM). In treatment groups 2 through 5, spermatozoa were washed by centrifugation (300 x g for 15 min) and resuspended in NFDSM to a final concentration of 25 x 10(6) spermatozoa/ml. Porcine pancreatic lipase (pPL) was added to Treatment 3 (10 pPL units/ml), Treatment 4 (100 pPL units/ml) and Treatment 5 (100 pPL units/ml, heat inactivated at 100 degrees C for 5 min) while Treatment 2 had no pancreatic lipase added and served as the control. Samples were cooled slowly to 5 degrees C, and stored at 5 degrees C until evaluation. Sperm motility was evaluated at time 0, 24, 48 and 72 h by computerized semen analysis, and data were analyzed via repeated measures ANOVA. The addition of 100 units/ml but not 10 units/ml of pPL decreased (P < 0.01) total and progressive motility of stored sperm. Heat-inactivated pPL (Treatment 5) did not significantly decrease motility of spermatozoa during storage. Because the lipase activity assayed (Sigma units) and the lipase activity added to cooled semen (pPL units) were not equivalent, pPL was assayed in the Sigma Diagnostic Lipase assay. The relationship between Sigma Units (Y) and pPL units (X) appeared to be a log-linear relationship with log(Y) = -0.912 + 0.007X; R2 = 0.90. Mean lipase activity assayed in stallion seminal plasma was equivalent to approximately 64 pPL units/ml. These data suggest that endogenous lipase activity in stallion seminal plasma may be a factor in the adverse effects of seminal plasma on cooled spermatozoa in some stallions.
Wagner, S J; Skripchenko, A; Seetharaman, S; Kurtz, J
2015-04-01
Previous studies with p38MAPK inhibitors at room temperature demonstrated that they improve a large number of platelet storage parameters, but cannot substantially inhibit p38MAPK activation nor protect against widespread decrements in platelet quality parameters during 4 °C storage. In this study, platelet quality parameters and inhibition of p38MAPK by VX-702 were studied after incubation of platelets at 16 °C without agitation, suboptimal storage conditions which produce moderate platelet decrements. Trima apheresis units were collected and aliquoted into three 60-ml CLX storage bags: (i) a control aliquot which was held at 20-24 °C with constant agitation; (ii) a test aliquot which was held at 20-24 °C with agitation until Day 2, when it was reincubated at 16 ± 1 °C for 24 ± 0·5 h without agitation and then returned 20-24 °C with agitation; (iii) a test aliquot containing 1 μm VX-702 stored in an identical fashion as aliquot 2. Aliquots were tested for an array of platelet storage parameters and p38MAPK activation on Days 1, 4 and 7. Many platelet storage parameters and p38MAPK activation were adversely affected by 24-h incubation at 16 °C without agitation. With the exception of ESC, addition of VX-702 prevented p38MAPK activation and the decrements in most observed parameters. Unlike 4 °C storage, VX-702 prevents activation of p38MAPK and decrements in many platelet storage parameters after exposure to 16 °C without agitation for 24 h. © 2014 International Society of Blood Transfusion.
Johnson, L; Kwok, M; Marks, D C
2015-02-01
The ErySep system represents an alternative to centrifuge-based whole blood (WB) separation, using gravity and filtration through hollow-fibres (0·2 µm pore size) to produce red blood cell (RBC) and plasma components. The aim of this study was to characterise the quality of ErySep RBC and plasma units compared with standard products from WB held overnight. Two ABO-compatible WB units (n = 24) were pooled and split to produce matched products. One of the WB units was separated into components using the ErySep system (ErySep; n = 12), whereas the other units were separated by centrifugation (control; n = 12). RBC units were stored at 2-6 °C and assessed for in vitro quality over 42 days of storage. Plasma was frozen at -30 °C and tested upon thawing. Processing WB with the ErySep system took longer than controls. The ErySep RBC units were of an appropriate volume (307 ± 17 mL) and contained sufficient Hb (50 ± 2 g unit(-1) ). ErySep RBC components contained more microparticles relative to controls at expiry. The plasma volume, total protein, coagulation factor activity (fibrinogen, FV, FVIII) and number of microparticles was lower in the ErySep units compared with controls. Following overnight hold of WB, the ErySep system was capable of producing RBC components that met specifications. However, the ErySep plasma components did not meet quality specifications. © 2015 British Blood Transfusion Society.
10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The maximum...
10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The maximum...
10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The maximum...
10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The maximum...
10 CFR 34.21 - Limits on external radiation levels from storage containers and source changers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Limits on external radiation levels from storage... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.21 Limits on external radiation levels from storage containers and source changers. The maximum...
Hinaman, Kurt
2005-01-01
The Powder River Basin in Wyoming and Montana is an important source of energy resources for the United States. Coalbed methane gas is contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. This gas is released when water pressure in coalbeds is lowered, usually by pumping ground water. Issues related to disposal and uses of by-product water from coalbed methane production have developed, in part, due to uncertainties in hydrologic properties. One hydrologic property of primary interest is the amount of water contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. The U.S. Geological Survey, in cooperation with the Bureau of Land Management, conducted a study to describe the hydrogeologic framework and to estimate ground-water volumes in different facies of Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin in Wyoming. A geographic information system was used to compile and utilize hydrogeologic maps, to describe the hydrogeologic framework, and to estimate the volume of ground water in Tertiary and upper Cretaceous hydrogeologic units in the Powder River structural basin in Wyoming. Maps of the altitudes of potentiometric surfaces, altitudes of the tops and bottoms of hydrogeologic units, thicknesses of hydrogeologic units, percent sand of hydrogeologic units, and outcrop boundaries for the following hydrogeologic units were used: Tongue River-Wasatch aquifer, Lebo confining unit, Tullock aquifer, Upper Hell Creek confining unit, and the Fox Hills-Lower Hell Creek aquifer. Literature porosity values of 30 percent for sand and 35 percent for non-sand facies were used to calculate the volume of total ground water in each hydrogeologic unit. Literature specific yield values of 26 percent for sand and 10 percent for non-sand facies, and literature specific storage values of 0.0001 ft-1 (1/foot) for sand facies and 0.00001 ft-1 for non-sand facies, were used to calculate a second volume of ground water for each hydrogeologic unit. Significant figure considerations limited estimates of ground-water volumes to two significant digits. A total ground-water volume of 2.0x1014 ft3 (cubic feet) was calculated using porosity values, and a total ground-water volume of 3.6x1013 ft3 was calculated using specific yield and specific storage values. These results are consistent with retention properties, which would have some of the total water being retained in the sediments. Sensitivity analysis shows that the estimates of ground-water volume are most sensitive to porosity. The estimates also are sensitive to confined thickness and saturated thickness. Better spatial information for hydrogeologic units could help refine the ground-water volume estimates.
The effect of pre-storage cooling on 2,3-DPG levels in red cells stored in SAG-M.
Llohn, Abid Hussain; Vetlesen, Annette; Fagerhol, Magne Kristoffer; Kjeldsen-Kragh, Jens
2005-10-01
The concentration of red cell 2,3-DPG (2,3-diphosphoglycerate) rapidly decreases during storage. A favourable effect on red cell 2,3-DPG has been demonstrated by rapid cooling of whole blood prior to storage. In our study we have investigated how different methods of cooling whole blood immediately after donation effect 2,3-DPG levels during storage. Thirty-six whole blood units (in 6 groups) of 450 ml were collected in 63 ml CPD. SAG-M was used as preservative solution for red cell concentrates (RCC). The units in one group were cooled down at ambient temperature, while units in the other groups were cooled down rapidly by different ways immediately after bleeding. Samples from the whole blood units were collected at various days during storage for 2,3-DPG measurements. The decline in 2,3-DPG during the first two weeks of storage was significantly slower in the groups which were cooled down rapidly to 17-18 degrees C within 1h after bleeding (all p
Vaccine stability study design and analysis to support product licensure.
Schofield, Timothy L
2009-11-01
Stability evaluation supporting vaccine licensure includes studies of bulk intermediates as well as final container product. Long-term and accelerated studies are performed to support shelf life and to determine release limits for the vaccine. Vaccine shelf life is best determined utilizing a formal statistical evaluation outlined in the ICH guidelines, while minimum release is calculated to help assure adequate potency through handling and storage of the vaccine. In addition to supporting release potency determination, accelerated stability studies may be used to support a strategy to recalculate product expiry after an unintended temperature excursion such as a cold storage unit failure or mishandling during transport. Appropriate statistical evaluation of vaccine stability data promotes strategic stability study design, in order to reduce the uncertainty associated with the determination of the degradation rate, and the associated risk to the customer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuang, Xingya; Shankar, T.J.; Bi, X.T.
Wood pellets emit CO, CO2, CH4 and other volatiles during storage. Increased concentration of these gases in a sealed storage causes depletion of concentration of oxygen. The storage environment becomes toxic to those who operate in and around these storages. The objective of this study was to investigate the effects of temperature, moisture and storage headspace on emissions from wood pellets in an enclosed space. Twelve 10-liter plastic containers were used to study the effects of headspace ratio (25%, 50%, and 75% of container volume) and temperatures (10-50oC). Another eight containers were set in uncontrolled storage relative humidity and temperature.more » Concentrations of CO2, CO and CH4 were measured by a gas chromatography (GC). The results showed that emissions of CO2, CO and CH4 from stored wood pellets are most sensitive to storage temperature. Higher peak emission factors are associated with higher temperatures. Increased headspace volume ratio increases peak off-gas emissions because of the availability of oxygen for pellet decomposition. Increased relative humidity in the enclosed container increases the rate of off-gas emissions of CO2, CO and CH4 and oxygen depletion.« less
9 CFR 317.13 - Storage and distribution of labels and containers bearing official marks.
Code of Federal Regulations, 2010 CFR
2010-01-01
... containers bearing official marks. 317.13 Section 317.13 Animals and Animal Products FOOD SAFETY AND... General § 317.13 Storage and distribution of labels and containers bearing official marks. Labels, wrappers, and containers bearing any official marks, with or without the establishment number, may be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
2009-08-01
Corrective Action Unit (CAU) 166 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Storage Yards and Contaminated Materials' and consists of the following seven Corrective Action Sites (CASs), located in Areas 2, 3, 5, and 18 of the Nevada Test Site: CAS 02-42-01, Condo Release Storage Yd - North; CAS 02-42-02, Condo Release Storage Yd - South; CAS 02-99-10, D-38 Storage Area; CAS 03-42-01, Conditional Release Storage Yard; CAS 05-19-02, Contaminated Soil and Drum; CAS 18-01-01, Aboveground Storage Tank; and CAS 18-99-03, Wax Piles/Oil Stain. Closure activities were conducted from March to July 2009 according tomore » the FF ACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 166 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action and Clean Closure. Closure activities are summarized. CAU 166, Storage Yards and Contaminated Materials, consists of seven CASs in Areas 2, 3, 5, and 18 of the NTS. The closure alternatives included No Further Action and Clean Closure. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 166 as documented in this CR: (1) At CAS 02-99-10, D-38 Storage Area, approximately 40 gal of lead shot were removed and are currently pending treatment and disposal as MW, and approximately 50 small pieces of DU were removed and disposed as LLW. (2) At CAS 03-42-01, Conditional Release Storage Yard, approximately 7.5 yd{sup 3} of soil impacted with lead and Am-241 were removed and disposed as LLW. As a BMP, approximately 22 ft{sup 3} of asbestos tile were removed from a portable building and disposed as ALLW, approximately 55 gal of oil were drained from accumulators and are currently pending disposal as HW, the portable building was removed and disposed as LLW, and accumulators, gas cylinders, and associated debris were removed and are currently pending treatment and disposal as MW. (3) At CAS 05-19-02, Contaminated Soil and Drum, as a BMP, an empty drum was removed and disposed as sanitary waste. (4) At CAS 18-01-01, Aboveground Storage Tank, approximately 165 gal of lead-impacted liquid were removed and are currently pending disposal as HW, and approximately 10 gal of lead shot and 6 yd{sup 3} of wax embedded with lead shot were removed and are currently pending treatment and disposal as MW. As a BMP, approximately 0.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, approximately 55 gal of liquid were removed and disposed as sanitary waste, and two metal containers were grouted in place. (5) At CAS 18-99-03, Wax Piles/Oil Stain, no further action was required; however, as a BMP, approximately l.5 yd{sup 3} of wax were removed and disposed as hydrocarbon waste, and one metal container was grouted in place.« less
Heitzinger, K; Rocha, C A; Quick, R E; Montano, S M; Tilley, D H; Mock, C N; Carrasco, A J; Cabrera, R M; Hawes, S E
2016-07-01
Boiling is the most common method of household water treatment in developing countries; however, it is not always effectively practised. We conducted a randomized controlled trial among 210 households to assess the effectiveness of water pasteurization and safe-storage interventions in reducing Escherichia coli contamination of household drinking water in a water-boiling population in rural Peru. Households were randomized to receive either a safe-storage container or a safe-storage container plus water pasteurization indicator or to a control group. During a 13-week follow-up period, households that received a safe-storage container and water pasteurization indicator did not have a significantly different prevalence of stored drinking-water contamination relative to the control group [prevalence ratio (PR) 1·18, 95% confidence interval (CI) 0·92-1·52]. Similarly, receipt of a safe-storage container alone had no effect on prevalence of contamination (PR 1·02, 95% CI 0·79-1·31). Although use of water pasteurization indicators and locally available storage containers did not increase the safety of household drinking water in this study, future research could illuminate factors that facilitate the effective use of these interventions to improve water quality and reduce the risk of waterborne disease in populations that boil drinking water.
A Shipping Container-Based Sterile Processing Unit for Low Resources Settings
2016-01-01
Deficiencies in the sterile processing of medical instruments contribute to poor outcomes for patients, such as surgical site infections, longer hospital stays, and deaths. In low resources settings, such as some rural and semi-rural areas and secondary and tertiary cities of developing countries, deficiencies in sterile processing are accentuated due to the lack of access to sterilization equipment, improperly maintained and malfunctioning equipment, lack of power to operate equipment, poor protocols, and inadequate quality control over inventory. Inspired by our sterile processing fieldwork at a district hospital in Sierra Leone in 2013, we built an autonomous, shipping-container-based sterile processing unit to address these deficiencies. The sterile processing unit, dubbed “the sterile box,” is a full suite capable of handling instruments from the moment they leave the operating room to the point they are sterile and ready to be reused for the next surgery. The sterile processing unit is self-sufficient in power and water and features an intake for contaminated instruments, decontamination, sterilization via non-electric steam sterilizers, and secure inventory storage. To validate efficacy, we ran tests of decontamination and sterilization performance. Results of 61 trials validate convincingly that our sterile processing unit achieves satisfactory outcomes for decontamination and sterilization and as such holds promise to support healthcare facilities in low resources settings. PMID:27007568
Gas storage cylinder formed from a composition containing thermally exfoliated graphite
NASA Technical Reports Server (NTRS)
Aksay, Ilhan A. (Inventor); Prud'Homme, Robert K. (Inventor)
2012-01-01
A gas storage cylinder or gas storage cylinder liner, formed from a polymer composite, containing at least one polymer and a modified graphite oxide material, which is a thermally exfoliated graphite oxide with a surface area of from about 300 m(exp 2)/g to 2600 m(exp 2)2/g.
2003-09-02
KENNEDY SPACE CENTER, FLA. - Workers in the Columbia Debris Hangar pull items from storage containers to transfer to storage in the Vehicle Assembly Building. About 83,000 pieces were shipped to KSC during search and recovery efforts in East Texas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coenenberg, J.G.
1997-08-15
The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit applicationmore » guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating text. 38 39 Information provided in this Liquid Effluent Retention Facility and 40 200 Area Effluent Treatment Facility permit application documentation is 41 current as of June 1, 1997.« less
On-site low level radwaste storage facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knauss, C.H.; Gardner, D.A.
1993-12-31
This paper will explore several storage and processing technologies that are available for the safe storage of low-level waste, their advantages and their limitations such that potential users may be able to determine which technology may be most appropriate for their particular application. Also, a brief discussion will be included on available types of shipping and disposal containers and waste forms for use in those containers when ready for ultimate disposal. For the purposes of this paper, the waste streams considered will be restricted to nuclear power plant wastes. Wastes that will be discussed are powdered and bead resins formore » cooling and reactor water clean-up, filter cartridges, solidified waste oils, and Dry Active Wastes (DAW), which consist of contaminated clothing, tools, respirator filters, etc. On-site storage methods that will be analyzed include a storage facility constructed of individual temporary shielded waste containers on a hard surface; an on-site, self contained low level radwaste facility for resins and filters; and an on-site storage and volume reduction facility for resins and filters; and an on-site DAW. Simple, warehouse-type buildings and pre-engineered metal buildings will be discussed only to a limited degree since dose rate projections can be high due to their lack of adequate shielding for radiation protection. Waste processing alternatives that will be analyzed for resins include dewatering, solidifying in Portland cement, solidifying in bituminous material, and solidifying in a vinyl ester styrene matrix. The storage methods describes will be analyzed for their ability to shield the populace from the effects of direct transmission and skyshine radiation when storing the above mentioned materials, which have been properly processed for storage and have been placed in suitable storage containers.« less
Containment and storage of uranium hexafluoride at US Department of Energy uranium enrichment plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barlow, C.R.; Alderson, J.H.; Blue, S.C.
Isotopically depleted UF{sub 6} (uranium hexafluoride) accumulates at a rate five to ten times greater than the enriched product and is stored in steel vessels at the enrichment plant sites. There are approximately 55,000 large cylinders now in storage at Paducah, Kentucky; Portsmouth, Ohio; and Oak Ridge, Tennessee. Most of them contain a nominal 14 tons of depleted UF{sub 6}. Some of these cylinders have been in the unprotected outdoor storage environment for periods approaching 40 years. Storage experience, supplemented by limited corrosion data, suggests a service life of about 70 years under optimum conditions for the 48-in. diameter, 5/16-in.-wallmore » pressure vessels (100 psi working pressure), using a conservative industry-established 1/4-in.-wall thickness as the service limit. In the past few years, however, factors other than atmospheric corrosion have become apparent that adversely affect the serviceability of small numbers of the storage containers and that indicate the need for a managed program to ensure maintenance ofcontainment integrity for all the cylinders in storage. The program includes periodic visual inspections of cylinders and storage yards with documentation for comparison with other inspections, a group of corrosion test programs to permit cylinder life forecasts, and identification of (and scheduling for remedial action) situations in which defects, due to handling damage or accelerated corrosion, can seriously shorten the storage life or compromise the containment integrity of individual cylinders. The program also includes rupture testing to assess the effects of certain classes of damage on overall cylinder strength, aswell as ongoing reviews of specifications, procedures, practices, and inspection results to effect improvements in handling safety, containment integrity, and storage life.« less
Environmental Control Unit with Integral Thermal Storage
2014-06-12
integrated PCM Heat Exchanger (PHX) to provide thermal energy storage . By storing thermal energy during the hottest part of the day and rejecting this stored...Environmental Control Unit (ECU) that uses an integrated PCM Heat Exchanger (PHX) to provide thermal energy storage . To aid in the development of the PHX...Thermal Storage 5a. CONTRACT NUMBER W911QX-14-C-0014 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Michael C. Ellis Ryan McDevitt 5d
Surveillance Report on SAVY-4000 and Hagan Nuclear Material Storage Containers for FY 2017
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reeves, Kirk Patrick; Karns, Tristan; Weis, Eric
In accordance with the SAVY-4000 Surveillance Plan [1] and DOE M441.1-1 requirements, storage container surveillance continued through fiscal year 2017 at Los Alamos National Laboratory. Surveillance items for the year consisted of 8 SAVY-4000 storage containers, 8 Hagan containers, and 39 SAVY-4000 transfer containers. The SAVY-4000 surveillance items ranged in age from 1 year to 5.6 years and the Hagan containers ranged in age from 6.3 years to 17.6 years. The surveillance containers for this year were selected primarily to better understand the extent of corrosion of the stainless steel components of the containers. Accelerated aging studies indicate that themore » O-ring and filter components of the SAVY-4000 will last at least 40 years under LANL storage conditions. However, the observation of corrosion on the inside of SAVY-4000 and Hagan surveillance containers has shifted the emphasis to understanding both the nature and the extent of corrosion on the stainless steel body. The restriction on handling soluble residues greater than 500 grams continued this year, delaying the surveillance of some items that was scheduled in earlier surveillance plans.« less
Modernisation Issues of Diesel-Electric Shunting Locomotive Power Units
NASA Astrophysics Data System (ADS)
Hoimoja, Hardi; Jalakas, Tanel; Rosin, Argo; Rassylkin, Anton
2010-01-01
The research concentrates on the modernisation issues of inefficient diesel-electric shunting locomotives, produced in the former Soviet Union. The existing diesel-generator unit, serving as an onboard power plant can be replaced by hybridised units, with an energy storage unit acting as a peaking power source for dynamic modes. By integrating an energy storage unit into the power plant, the locomotive traction drive becomes hybridised, consuming less fuel during transients and idling.
Container Seedling Handling and Storage in the Southeastern States
Kasten R. Dumroese; James P. Barnett
2004-01-01
Most container seedlings grown in the southeastern US are outplanted during winter, although 10 to 20% are outplanted during summer. Longleaf pine accounts for more than 80% of all container seedlings produced. Very little information is published on cold hardiness and storage effects on container-grown southern pines and hardwoods. In general, growers attempt to...
Bypass apparatus and method for series connected energy storage devices
Rouillard, Jean; Comte, Christophe; Daigle, Dominik
2000-01-01
A bypass apparatus and method for series connected energy storage devices. Each of the energy storage devices coupled to a common series connection has an associated bypass unit connected thereto in parallel. A current bypass unit includes a sensor which is coupled in parallel with an associated energy storage device or cell and senses an energy parameter indicative of an energy state of the cell, such as cell voltage. A bypass switch is coupled in parallel with the energy storage cell and operable between a non-activated state and an activated state. The bypass switch, when in the non-activated state, is substantially non-conductive with respect to current passing through the energy storage cell and, when in the activated state, provides a bypass current path for passing current to the series connection so as to bypass the associated cell. A controller controls activation of the bypass switch in response to the voltage of the cell deviating from a pre-established voltage setpoint. The controller may be included within the bypass unit or be disposed on a control platform external to the bypass unit. The bypass switch may, when activated, establish a permanent or a temporary bypass current path.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NNSA /NSO
The Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 204 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 204 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of six Corrective Action Sites (CASs) which include: 01-34-01, Underground Instrument House Bunker; 02-34-01, Instrument Bunker; 03-34-01, Underground Bunker; 05-18-02, Chemical Explosives Storage; 05-33-01, Kay Blockhouse; 05-99-02, Explosive Storage Bunker.more » Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for Corrective Action Unit 204 collectively include radionuclides, beryllium, high explosives, lead, polychlorinated biphenyls, total petroleum hydrocarbons, silver, warfarin, and zinc phosphide. The primary question for the investigation is: ''Are existing data sufficient to evaluate appropriate corrective actions?'' To address this question, resolution of two decision statements is required. Decision I is to ''Define the nature of contamination'' by identifying any contamination above preliminary action levels (PALs); Decision II is to ''Determine the extent of contamination identified above PALs. If PALs are not exceeded, the investigation is completed. If PALs are exceeded, then Decision II must be resolved. In addition, data will be obtained to support waste management decisions. Field activities will include radiological land area surveys, geophysical surveys to identify any subsurface metallic and nonmetallic debris, field screening for applicable contaminants of potential concern, collection and analysis of surface and subsurface soil samples from biased locations, and step-out sampling to define the extent of contamination, as necessary. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.« less
Final Report: Characterization of Canister Mockup Weld Residual Stresses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enos, David; Bryan, Charles R.
2016-12-01
Stress corrosion cracking (SCC) of interim storage containers has been indicated as a high priority data gap by the Department of Energy (DOE) (Hanson et al., 2012), the Electric Power Research Institute (EPRI, 2011), the Nuclear Waste Technical Review Board (NWTRB, 2010a), and the Nuclear Regulatory Commission (NRC, 2012a, 2012b). Uncertainties exist in terms of the environmental conditions that prevail on the surface of the storage containers, the stress state within the container walls associated both with weldments as well as within the base metal itself, and the electrochemical properties of the storage containers themselves. The goal of the workmore » described in this document is to determine the stress states that exists at various locations within a typical storage canister by evaluating the properties of a full-diameter cylindrical mockup of an interim storage canister. This mockup has been produced using the same manufacturing procedures as the majority of the fielded spent nuclear fuel interim storage canisters. This document describes the design and procurement of the mockup and the characterization of the stress state associated with various portions of the container. It also describes the cutting of the mockup into sections for further analyses, and a discussion of the potential impact of the results from the stress characterization effort.« less
Survey of solar thermal energy storage subsystems for thermal/electric applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Segaser, C. L.
1978-08-01
A survey of the current technology and estimated costs of subsystems for storing the thermal energy produced by solar collectors is presented. The systems considered were capable of producing both electricity and space conditioning for three types of loads: a single-family detached residence, an apartment complex of 100 units, and a city of 30,000 residents, containing both single-family residences and apartments. Collector temperatures will be in four ranges: (1) 100 to 250/sup 0/F (used for space heating and single-cycle air conditioners and organic Rankine low-temperature turbines); (2) 300 to 400/sup 0/F (used for dual-cycle air conditioners and low-temperature turbines); (3)more » 400 to 600/sup 0/F (using fluids from parabolic trough collectors to run Rankine turbines); (4) 800 to 1000/sup 0/F (using fluids from heliostats to run closed-cycle gas turbines and steam Rankine turbines). The solar thermal energy subsystems will require from 60 to 36 x 10/sup 5/ kWhr (2.05 x 10/sup 5/ to 1.23 x 10/sup 10/ Btu) of thermal storage capacity. In addition to sensible heat and latent heat storage materials, several other media were investigated as potential thermal energy storage materials, including the clathrate and semiclathrate hydrates, various metal hydrides, and heat storage based on inorganic chemical reactions.« less
Cloud archiving and data mining of High-Resolution Rapid Refresh forecast model output
NASA Astrophysics Data System (ADS)
Blaylock, Brian K.; Horel, John D.; Liston, Samuel T.
2017-12-01
Weather-related research often requires synthesizing vast amounts of data that need archival solutions that are both economical and viable during and past the lifetime of the project. Public cloud computing services (e.g., from Amazon, Microsoft, or Google) or private clouds managed by research institutions are providing object data storage systems potentially appropriate for long-term archives of such large geophysical data sets. We illustrate the use of a private cloud object store developed by the Center for High Performance Computing (CHPC) at the University of Utah. Since early 2015, we have been archiving thousands of two-dimensional gridded fields (each one containing over 1.9 million values over the contiguous United States) from the High-Resolution Rapid Refresh (HRRR) data assimilation and forecast modeling system. The archive is being used for retrospective analyses of meteorological conditions during high-impact weather events, assessing the accuracy of the HRRR forecasts, and providing initial and boundary conditions for research simulations. The archive is accessible interactively and through automated download procedures for researchers at other institutions that can be tailored by the user to extract individual two-dimensional grids from within the highly compressed files. Characteristics of the CHPC object storage system are summarized relative to network file system storage or tape storage solutions. The CHPC storage system is proving to be a scalable, reliable, extensible, affordable, and usable archive solution for our research.
21. Detail of typical refrigeration unit in the southwest corner ...
21. Detail of typical refrigeration unit in the southwest corner of the fruit and vegetable storage room - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX
Nuclear waste disposal: Gambling on Yucca Mountain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ginsburg, S.
1995-05-01
This document describes the historical aspects of nuclear energy ,nuclear weapons usage, and development of the nuclear bureaucracy in the United States, and discusses the selection and siting of Yucca Mountain, Nevada for a federal nuclear waste repository. Litigation regarding the site selection and resulting battles in the political arena and in the Nevada State Legislature are also presented. Alternative radioactive waste disposal options, risk assessments of the Yucca Mountain site, and logistics regarding the transportation and storage of nuclear waste are also presented. This document also contains an extensive bibliography.
1987-01-01
after the MYCIN expert system. Host Computer PC+ is available on both symbolic and numeric computers. It operates on: the IBM PC AT, TI Bus- Pro (IBM PC...suppose that the data baseTool picks up pace contains 100 motors, and in only one case does a lightweight motor pro . duce more power than heavier units...every sor, ART 2.0. In the bargain it con - the figure). decision point takes time. More sub- sumes 10 times less storage. ART 3.0 reduces the comparison
Conversion of raw carbonaceous fuels
Cooper, John F [Oakland, CA
2007-08-07
Three configurations for an electrochemical cell are utilized to generate electric power from the reaction of oxygen or air with porous plates or particulates of carbon, arranged such that waste heat from the electrochemical cells is allowed to flow upwards through a storage chamber or port containing raw carbonaceous fuel. These configurations allow combining the separate processes of devolatilization, pyrolysis and electrochemical conversion of carbon to electric power into a single unit process, fed with raw fuel and exhausting high BTU gases, electric power, and substantially pure CO.sub.2 during operation.
Goodman, Angela; Hakala, J. Alexandra; Bromhal, Grant; Deel, Dawn; Rodosta, Traci; Frailey, Scott; Small, Michael; Allen, Doug; Romanov, Vyacheslav; Fazio, Jim; Huerta, Nicolas; McIntyre, Dustin; Kutchko, Barbara; Guthrie, George
2011-01-01
A detailed description of the United States Department of Energy (US-DOE) methodology for estimating CO2 storage potential for oil and gas reservoirs, saline formations, and unmineable coal seams is provided. The oil and gas reservoirs are assessed at the field level, while saline formations and unmineable coal seams are assessed at the basin level. The US-DOE methodology is intended for external users such as the Regional Carbon Sequestration Partnerships (RCSPs), future project developers, and governmental entities to produce high-level CO2 resource assessments of potential CO2 storage reservoirs in the United States and Canada at the regional and national scale; however, this methodology is general enough that it could be applied globally. The purpose of the US-DOE CO2 storage methodology, definitions of storage terms, and a CO2 storage classification are provided. Methodology for CO2 storage resource estimate calculation is outlined. The Log Odds Method when applied with Monte Carlo Sampling is presented in detail for estimation of CO2 storage efficiency needed for CO2 storage resource estimates at the regional and national scale. CO2 storage potential reported in the US-DOE's assessment are intended to be distributed online by a geographic information system in NatCarb and made available as hard-copy in the Carbon Sequestration Atlas of the United States and Canada. US-DOE's methodology will be continuously refined, incorporating results of the Development Phase projects conducted by the RCSPs from 2008 to 2018. Estimates will be formally updated every two years in subsequent versions of the Carbon Sequestration Atlas of the United States and Canada.
2003-09-02
KENNEDY SPACE CENTER, FLA. - Storage boxes and other containers of Columbia debris wait in the Columbia Debris Hangar for transfer to storage in the Vehicle Assembly Building. About 83,000 pieces were shipped to KSC during search and recovery efforts in East Texas.
Conservation of coconut (Cocos nucifera L.) germplasm at sub-zero temperature.
Sisunandar; Sopade, Peter A; Samosir, Yohannes M S; Rival, Alain; Adkins, Steve W
2012-01-01
Protocols are proposed for the low (-20 degree C) and ultra-low (-80 degree C) temperature storage of coconut (Cocos nucifera L.) embryos. A tissue dehydration step prior to storage, and a rapid warming step upon recovery optimized the protocol. The thermal properties of water located within embryos were monitored using differential scanning calorimetry (DSC). In the most efficient version of the protocol, embryos were dehydrated under a sterile air flow in a dehydration solution containing glucose (3.33 M) and glycerol (15 percent) for 16 hours. This protocol decreased the embryo water content from 77 to 29 percent FW and at the same time reduced the amount of freezable water down to 0.03 percent. The dehydrated embryos could be stored for up to 3 weeks at -20 degree C (12 percent producing normal plants upon recovery) or 26 weeks at -80 degree C (28 percent producing normal plants upon recovery). These results indicate that it is possible to store coconut germplasm on a medium term basis using an ultra-deep freezer unit. However for more efficient, long term storage, cryopreservation remains the preferred option.
The Kepler Science Operations Center Pipeline Framework Extensions
NASA Technical Reports Server (NTRS)
Klaus, Todd C.; Cote, Miles T.; McCauliff, Sean; Girouard, Forrest R.; Wohler, Bill; Allen, Christopher; Chandrasekaran, Hema; Bryson, Stephen T.; Middour, Christopher; Caldwell, Douglas A.;
2010-01-01
The Kepler Science Operations Center (SOC) is responsible for several aspects of the Kepler Mission, including managing targets, generating on-board data compression tables, monitoring photometer health and status, processing the science data, and exporting the pipeline products to the mission archive. We describe how the generic pipeline framework software developed for Kepler is extended to achieve these goals, including pipeline configurations for processing science data and other support roles, and custom unit of work generators that control how the Kepler data are partitioned and distributed across the computing cluster. We describe the interface between the Java software that manages the retrieval and storage of the data for a given unit of work and the MATLAB algorithms that process these data. The data for each unit of work are packaged into a single file that contains everything needed by the science algorithms, allowing these files to be used to debug and evolve the algorithms offline.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yaghi, Omar M.; Goddard, William A.
2013-06-29
Conventional storage of large amounts of hydrogen in its molecular form is difficult and expensive because it requires employing either extremely high pressure gas or very low temperature liquid. Because of the importance of hydrogen as a fuel, the DOE has set system targets for hydrogen storage of gravimetric (5.5 wt%) and volumetric (40 g/L) densities to be achieved by 2015. From our continuous efforts on hydrogen storage, it is believed that metalation of highly porous solids with high-valence metals is promising and provides a rational direction to realize high volumetric hydrogen density near room temperature. This grant was focusedmore » on the study of high surface area covalent organic frameworks (COFs) with these specific objectives (1) to introduce potential metal binding sites through the COF synthesis and (2) to implement metalation experiments and evaluate their respective hydrogen adsorption properties. To maximize our efforts, simulation calculations were also performed (prior to experiments) for the prediction of binding enthalpy of hydrogen for molecular building units containing transition metals and promising COF structures to increase volumetric hydrogen uptake at room temperature. In this effort, first molecular building units with optimal binding energy for hydrogen storage (20 kJ/mol) were designed by quantum mechanical (QM) methods. Employing these results, it was revealed that one of metalated COFs takes up 60 g/L (total) of H2 at 100 bar and 298 K. To realize proposed COF structures, chemistry of COF synthesis has been developed; for instance, new air stable COFs were synthesized via hydrazone (COF-41 to 43) and imine condensation (COF-301, 320, 340, and 366) and some of them were tested the effect on metalation. Finally, a new triazine COF with high volumetric hydrogen uptake capacity was presented as a proposed future direction.« less
Baliarsingh, S; Jaiswal, M
2014-02-01
Potassium levels in stored blood bags increases as they age. Hyperkalemia in transfused blood has undesirable cardiac effects. Within a 19-month period, baseline and weekly samples from 15 CPDA-1 whole blood bags were collected till 28 days of storage and analysed for potassium, sodium, uric acid, albumin and whole blood haemoglobin. One unit increase in baseline (0 day) potassium in extracellular fluid of blood units was associated with the following increases in potassium levels on later days of storage: around two unit increase at 1 week (r2 = 0·50, P < 0·01) of storage; four units increase at 2 weeks (r2 = 0·64, P < 0·001) and 3 weeks (r2 = 0·51, P < 0·01) of storage; six units at 4 weeks (r2 = 0·53, P < 0·01) of storage. Baseline whole blood haemoglobin showed a moderate association with baseline potassium (r2 = 0·36, P < 0·05) and 2-week potassium (r2 = 0·35, P < 0·05) values. For CPDA-1 blood bags (i) low baseline potassium blood bags might be preferred for transfusion in cases demanding a low potassium load and (ii) coordinating the ‘first-in-first-out’ (FIFO) policy with ‘early release of blood-bags with high initial potassium’ might be helpful in improving the release of suitable blood units from blood-banks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... storage tank means any tank, reservoir, or container used to collect or store refined benzene. BTX storage tank means any tank, reservoir, or container used to collect or store benzene-toluene-xylene or other... tank, reservoir, or container used to collect or store a flushing liquor solution prior to ammonia or...
PROPULSE 980: A Hydrogen Peroxide Enrichment System
NASA Technical Reports Server (NTRS)
Boxwell, Robert; Bromley, G.; Wanger, Robert; Pauls, Dan; Maynard, Bryon; McNeal, Curtis; Dumbacher, D. L. (Technical Monitor)
2000-01-01
The PROPULSE 980 unit is a transportable processing plant that enriches aerospace grade hydrogen peroxide from 90% to 98% final concentration. The unit was developed by Degussa-H Is, in cooperation with Orbital, NASA Marshall Space Center, and NASA Stennis Space Center. The system is a self-contained unit that houses all of the process equipment, instrumentation and controls to perform the concentration operation nearly autonomously. It is designed to produce non-bulk quantities of 98% hydrogen peroxide. The enrichment unit design also maintains system, personnel and environmental safety during all aspects of the enrichment process and final product storage. As part of the Propulse 980 checkout and final buyoff, it will be disassembled at the Degussa-H Is Corporation plant in Theodore, AL, transported to the Stennis Space Center, reassembled and subjected to a series of checkout tests to verify design objectives have been met. This paper will summarize the basic project elements and provide an update on the present status of the project.
Underground storage of imported water in the San Gorgonio Pass area, southern California
Bloyd, Richard M.
1971-01-01
The San Gorgonio Pass ground-water basin is divided into the Beaumont, Banning, Cabazon, San Timoteo, South Beaumont, Banning Bench, and Singleton storage units. The Beaumont storage unit, centrally located in the agency area, is the largest in volume of the storage units. Estimated long-term average annual precipitation in the San Gorgonio Pass Water Agency drainage area is 332,000 acre-feet, and estimated average annual recoverable water is 24,000 acre-feet, less than 10 percent of the total precipitation. Estimated average annual surface outflow is 1,700 acre-feet, and estimated average annual ground-water recharge is 22,000 acre-feet. Projecting tack to probable steady-state conditions, of the 22.000 acre-feet of recharge, 16,003 acre-feet per year became subsurface outflow into Coachella Valley, 6,000 acre-feet into the Redlands area, and 220 acre-feet into Potrero Canyon. After extensive development, estimated subsurface outflow from the area in 1967 was 6,000 acre-feet into the Redlands area, 220 acre-feet into Potrero Canyon, and 800 acre-feet into the fault systems south of the Banning storage unit, unwatered during construction of a tunnel. Subsurface outflow into Coachella Valley in 1967 is probably less than 50 percent of the steady-state flow. An anticipated 17,000 .acre-feet of water per year will be imported by 1980. Information developed in this study indicates it is technically feasible to store imported water in the eastern part of the Beaumont storage unit without causing waterlogging in the storage area and without losing any significant quantity of stored water.
Certification of Compliance Audit Checklist for Hazardous Waste Container Storage Areas
Example of a Certification of Compliance Audit Checklist -- Container Storage, which includes a fillable table with areas to list requirements, federal regulations, descriptions, locations of information, and criteria met.
Saini, Nishant; Basu, Sabita; Kaur, Ravneet; Kaur, Jasbinder
2015-06-01
Red cell units undergo changes during storage and processing. The study was planned to assess plasma potassium, plasma hemoglobin, percentage hemolysis during storage and to determine the effects of outdoor blood collection and processing on those parameters. Blood collection in three types of blood storage bags was done - single CPDA bag (40 outdoor and 40 in-house collection), triple CPD + SAGM bag (40 in-house collection) and quadruple CPD + SAGM bag with integral leukoreduction filter (40 in-house collection). All bags were sampled on day 0 (day of collection), day 1 (after processing), day 7, day 14 and day 28 for measurement of percentage hemolysis and potassium levels in the plasma of bag contents. There was significant increase in percentage hemolysis, plasma hemoglobin and plasma potassium level in all the groups during storage (p < 0.001). No significant difference was found between any parameter analyzed for outdoor and in-house collected single CPDA red cell units. There was significant lower percentage hemolysis (p < 0.001) and potassium (day 7 to day 14 - p < 0.05 and day 14 to day 28 - p < 0.001) in red cell units from day 7 onward until day 28 of storage in the leukoreduced quadruple bag as compared to the triple bag. The in-house single CPDA red cell units showed significantly more hemolysis (p < 0.001) as compared to the triple bags with SAGM additive solution after 28 days of storage. There is gradual increase in plasma hemoglobin and plasma potassium levels during the storage of red blood cells. Blood collection can be safely undertaken in outdoor blood donation camps even in hot summer months in monitored blood transport boxes. SAGM additive solution decreases the red cell hemolysis and allows extended storage of red cells. Prestorage leukoreduction decreases the red cell hemolysis and improves the quality of blood. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of an integrated heat pipe-thermal storage system for a solar receiver
NASA Technical Reports Server (NTRS)
Keddy, E. S.; Sena, J. T.; Merrigan, M. A.; Heidenreich, G.; Johnson, S.
1987-01-01
The Organic Rankine Cycle (ORC) Solar Dynamic Power System (SDPS) is one of the candidates for Space Station prime power application. In the low Earth orbit of the Space Station approximately 34 minutes of the 94-minute orbital period is spent in eclipse with no solar energy input to the power system. For this period the SDPS will use thermal energy storage (TES) material to provide a constant power output. An integrated heat-pipe thermal storage receiver system is being developed as part of the ORC-SDPS solar receiver. This system incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain the TES canisters within the potassium vapor space with the toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the Earth orbit, solar energy is delivered to the heat pipe in the ORC-SDPS receiver cavity. The heat pipe transforms the non-uniform solar flux incident in the heat pipe surface within the receiver cavity to an essentially uniform flux at the potassium vapor condensation interface in the heat pipe. During solar insolation, part of the thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of the orbit, the balance stored in the TES units is transferred by the potassium vapor to the toluene heater tube.
High temperature thermal energy storage, including a discussion of TES integrated into power plants
NASA Technical Reports Server (NTRS)
Turner, R. H.
1978-01-01
Storage temperatures of 260 C and above are considered. Basic considerations concerning energy thermal storage are discussed, taking into account general aspects of thermal energy storage, thermal energy storage integrated into power plants, thermal storage techniques and technical considerations, and economic considerations. A description of system concepts is provided, giving attention to a survey of proposed concepts, storage in unpressurized fluids, water storage in pressurized containers, the use of an underground lined cavern for water storage, a submerged thin insulated steel shell under the ocean containing pressurized water, gas passage through solid blocks, a rock bed with liquid heat transport fluid, hollow steel ingots, heat storage in concrete or sand, sand in a fluidized bed, sand poured over pipes, a thermal energy storage heat exchanger, pipes or spheres filled with phase change materials (PCM), macroencapsulated PCM with heat pipe concept for transport fluid, solid PCM removed from heat transfer pipes by moving scrapers, and the direct contact between PCM and transport fluid.
Pipe overpack container for trasuranic waste storage and shipment
Geinitz, Richard R.; Thorp, Donald T.; Rivera, Michael A.
1999-01-01
A Pipe Overpack Container for transuranic waste storage and shipment. The system consists of a vented pipe component which is positioned in a vented, insulated 55 gallon steel drum. Both the vented pipe component and the insulated drum are capable of being secured to prevent the contents from leaving the vessel. The vented pipe component is constructed of 1/4 inch stainless steel to provide radiation shielding. Thus, allowing shipment having high Americium-241 content. Several Pipe Overpack Containers are then positioned in a type B, Nuclear Regulatory Commission (NRC) approved, container. In the current embodiment, a TRUPACT-II container was employed and a maximum of fourteen Pipe Overpack Containers were placed in the TRUPACT-II. The combination received NRC approval for the shipment and storage of transuranic waste.
Plastic container bagless transfer
Tibrea, Steven L.; D'Amelio, Joseph A.; Daugherty, Brent A.
2003-11-18
A process and apparatus are provided for transferring material from an isolated environment into a storage carrier through a conduit that can be sealed with a plug. The plug and conduit can then be severed to provide a hermetically sealed storage carrier containing the material which may be transported for storage or disposal and to maintain a seal between the isolated environment and the ambient environment.
Lahr, Rebecca H; Goetsch, Heather E; Haig, Sarah J; Noe-Hays, Abraham; Love, Nancy G; Aga, Diana S; Bott, Charles B; Foxman, Betsy; Jimenez, Jose; Luo, Ting; Nace, Kim; Ramadugu, Kirtana; Wigginton, Krista R
2016-11-01
Source-separated human urine was collected from six public events to study the impact of urine processing and storage on bacterial community composition and viability. Illumina 16S rRNA gene sequencing revealed a complex community of bacteria in fresh urine that differed across collection events. Despite the harsh chemical conditions of stored urine (pH > 9 and total ammonia nitrogen > 4000 mg N/L), bacteria consistently grew to 5 ± 2 × 10 8 cells/mL. Storing hydrolyzed urine for any amount of time significantly reduced the number of operational taxonomic units (OTUs) to 130 ± 70, increased Pielou evenness to 0.60 ± 0.06, and produced communities dominated by Clostridiales and Lactobacillales. After 80 days of storage, all six urine samples from different starting materials converged to these characteristics. Urine pasteurization or struvite precipitation did not change the microbial community, even when pasteurized urine was stored for an additional 70 days. Pasteurization decreased metabolic activity by 50 ± 10% and additional storage after pasteurization did not lead to recovery of metabolic activity. Urine-derived fertilizers consistently contained 16S rRNA genes belonging to Tissierella, Erysipelothrix, Atopostipes, Bacteroides, and many Clostridiales OTUs; additional experiments must determine whether pathogenic species are present, responsible for observed metabolic activity, or regrow when applied.
Nahlik, A. M.; Fennessy, M. S.
2016-01-01
Wetland soils contain some of the highest stores of soil carbon in the biosphere. However, there is little understanding of the quantity and distribution of carbon stored in our remaining wetlands or of the potential effects of human disturbance on these stocks. Here we use field data from the 2011 National Wetland Condition Assessment to provide unbiased estimates of soil carbon stocks for wetlands at regional and national scales. We find that wetlands in the conterminous United States store a total of 11.52 PgC, much of which is within soils deeper than 30 cm. Freshwater inland wetlands, in part due to their substantial areal extent, hold nearly ten-fold more carbon than tidal saltwater sites—indicating their importance in regional carbon storage. Our data suggest a possible relationship between carbon stocks and anthropogenic disturbance. These data highlight the need to protect wetlands to mitigate the risk of avoidable contributions to climate change. PMID:27958272
NASA Astrophysics Data System (ADS)
Nahlik, A. M.; Fennessy, M. S.
2016-12-01
Wetland soils contain some of the highest stores of soil carbon in the biosphere. However, there is little understanding of the quantity and distribution of carbon stored in our remaining wetlands or of the potential effects of human disturbance on these stocks. Here we use field data from the 2011 National Wetland Condition Assessment to provide unbiased estimates of soil carbon stocks for wetlands at regional and national scales. We find that wetlands in the conterminous United States store a total of 11.52 PgC, much of which is within soils deeper than 30 cm. Freshwater inland wetlands, in part due to their substantial areal extent, hold nearly ten-fold more carbon than tidal saltwater sites--indicating their importance in regional carbon storage. Our data suggest a possible relationship between carbon stocks and anthropogenic disturbance. These data highlight the need to protect wetlands to mitigate the risk of avoidable contributions to climate change.
Study to establish cost predictions for the production of Redox chemicals
NASA Technical Reports Server (NTRS)
Ammann, P. R.; Loreth, M.; Harvey, W. W.
1982-01-01
The chromium and iron chloride chemicals are significant first costs for NASA Redox energy storage systems. This study was performed to determine the lowest cost at which chromium and iron chlorides could be obtained for a complex of redox energy storage systems. In addition, since the solutions gradually become intermixed during the course of operation of Redox units, it was an objective to evaluate schemes for regeneration of the operating solutions. Three processes were evaluated for the production of chromium and iron chlorides. As a basis for the preliminary plant design and economic evaluation, it was assumed that the plant would produce about 25,000 tons of contained chromium as CrCl3 and an equivalent molar quantity of FeCl2. Preliminary plant designs, including materials and energy balances and sizing of major equipment, were prepared, and capital and operating costs were estimated.
NASA Astrophysics Data System (ADS)
Zhang, Yichi; Wang, Ping; Li, Liang; Chen, Zhimin; He, Chunying; Wu, Yiqun
Preparation of recording materials with high two-photon absorption activities is one of the important issues to superhigh- density two-photon absorption (TPA) three-dimensional (3D) optical data storage. In this paper, three new carbazole derivatives containing nitrogen heterocyclic ring with symmetric and asymmetric structures are prepared using ethylene as the π bridge between the carbazole unit and nitrogen heterocyclic ring, namely, 9-butyl-3-(2-(1,8- naphthyridin)vinyl)-carbazole (material 1), 9-butyl-3,6-bis(2-(1,8-naphthyl)vinyl)-carbazole (material 2) and 9-butyl-3,6- bis(2-(quinolin)vinyl)-carbazole (material 3). Their one photon properties including linear absorption spectra, fluorescence emission spectra, and fluorescence quantum yields are studied. The fluorescence excited by 120 fs pulse at 800 nm Ti: sapphire laser operating at 1 kHz repetition rate with different incident powers of 9-butyl-3-(2-(quinolin) vinyl)-carbazole (material 3) was investigated, and two-photon absorption cross-sections has been obtained. It is shown that material 3 containing quinoline rings as electron acceptor with symmetric structure exhibit high two-photon absorption activity. The result implies that material 3 (9-butyl-3-(2-(quinolin) vinyl)-carbazole) is a good candidate as a promising recording material for super-high-density two-photon absorption (TPA) three-dimensional (3D) optical data storage. The influence of chemical structure of the materials on the optical properties is discussed.
NASA Technical Reports Server (NTRS)
Sturman, J. C.
1985-01-01
Dynamic random-access-memory (RAM) data delay and storage unit developed to insure data received from satellite is stored and not lost when satellite is not within range of ground station. Stores 256K of serial data, with independent read and write capability.
CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 204: STORAGE BUNKERS, NEVADA TEST SITE, NEVADA
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Corrective Action Unit (CAU) 330 consists of four Corrective Action Sites (CASs) located in Areas 6, 22, and 23 of the Nevada Test Site (NTS). The unit is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) as CAU 330: Areas 6, 22, and 23 Tanks and Spill Sites. CAU 330 consists of the following CASs: CAS 06-02-04, Underground Storage Tank (UST) and Piping CAS 22-99-06, Fuel Spill CAS 23-01-02, Large Aboveground Storage Tank (AST) Farm CAS 23-25-05, Asphalt Oil Spill/Tar Release
Moropeng, Resoketswe Charlotte; Mpenyana-Monyatsi, Lizzy; Momba, Maggie Ndombo Benteke
2018-01-01
Development of biofilms occurring on the inner surface of storage vessels offers a suitable medium for the growth of microorganisms and consequently contributes to the deterioration of treated drinking water quality in homes. The aim of this study was to determine whether the two point-of-use technologies (biosand zeolite silver-impregnated clay granular (BSZ-SICG) filter and silver-impregnated porous pot (SIPP) filter) deployed in a rural community of South Africa could inhibit the formation of biofilm on the surface of plastic-based containers generally used by rural households for the storage of their drinking water. Culture-based methods and molecular techniques were used to detect the indicator bacteria (Total coliforms, faecal coliform, E. coli) and pathogenic bacteria (Salmonella spp., Shigella spp. and Vibrio cholerae) in intake water and on the surface of storage vessels containing treated water. Scanning electron microscopy was also used to visualize the development of biofilm. Results revealed that the surface water source used by the Makwane community was heavily contaminated and harboured unacceptably high counts of bacteria (heterotrophic plate count: 4.4–4.3 Log10 CFU/100mL, total coliforms: 2.2 Log10 CFU/100 mL—2.1 Log10 CFU/100 mL, faecal coliforms: 1.9 Log10 CFU/100 mL—1.8 Log10 CFU/100 mL, E. coli: 1.7 Log10 CFU/100 mL—1.6 Log10 CFU/100 mL, Salmonella spp.: 3 Log10 CFU/100 mL -8 CFU/100 mL; Shigella spp. and Vibrio cholerae had 1.0 Log10 CFU/100 mL and 0.8 Log10 CFU/100 mL respectively). Biofilm formation was apparent on the surface of the storage containers with untreated water within 24 h. The silver nanoparticles embedded in the clay of the filtration systems provided an effective barrier for the inhibition of biofilm formation on the surface of household water storage containers. Biofilm formation occurred on the surface of storage plastic vessels containing drinking water treated with the SIPP filter between 14 and 21 days, and on those containing drinking water treated with the BSZ-SICG filter between 3 and 14 days. The attachment of target bacteria on the surface of the coupons inoculated in storage containers ranged from (0.07 CFU/cm2–227.8 CFU/cm2). To effectively prevent the development of biofilms on the surface of container-stored water, which can lead to the recontamination of treated water, plastic storage containers should be washed within 14 days for water treated with the SIPP filter and within 3 days for water treated with the BSZ-SICG filter. PMID:29621296
Budeli, Phumudzo; Moropeng, Resoketswe Charlotte; Mpenyana-Monyatsi, Lizzy; Momba, Maggie Ndombo Benteke
2018-01-01
Development of biofilms occurring on the inner surface of storage vessels offers a suitable medium for the growth of microorganisms and consequently contributes to the deterioration of treated drinking water quality in homes. The aim of this study was to determine whether the two point-of-use technologies (biosand zeolite silver-impregnated clay granular (BSZ-SICG) filter and silver-impregnated porous pot (SIPP) filter) deployed in a rural community of South Africa could inhibit the formation of biofilm on the surface of plastic-based containers generally used by rural households for the storage of their drinking water. Culture-based methods and molecular techniques were used to detect the indicator bacteria (Total coliforms, faecal coliform, E. coli) and pathogenic bacteria (Salmonella spp., Shigella spp. and Vibrio cholerae) in intake water and on the surface of storage vessels containing treated water. Scanning electron microscopy was also used to visualize the development of biofilm. Results revealed that the surface water source used by the Makwane community was heavily contaminated and harboured unacceptably high counts of bacteria (heterotrophic plate count: 4.4-4.3 Log10 CFU/100mL, total coliforms: 2.2 Log10 CFU/100 mL-2.1 Log10 CFU/100 mL, faecal coliforms: 1.9 Log10 CFU/100 mL-1.8 Log10 CFU/100 mL, E. coli: 1.7 Log10 CFU/100 mL-1.6 Log10 CFU/100 mL, Salmonella spp.: 3 Log10 CFU/100 mL -8 CFU/100 mL; Shigella spp. and Vibrio cholerae had 1.0 Log10 CFU/100 mL and 0.8 Log10 CFU/100 mL respectively). Biofilm formation was apparent on the surface of the storage containers with untreated water within 24 h. The silver nanoparticles embedded in the clay of the filtration systems provided an effective barrier for the inhibition of biofilm formation on the surface of household water storage containers. Biofilm formation occurred on the surface of storage plastic vessels containing drinking water treated with the SIPP filter between 14 and 21 days, and on those containing drinking water treated with the BSZ-SICG filter between 3 and 14 days. The attachment of target bacteria on the surface of the coupons inoculated in storage containers ranged from (0.07 CFU/cm2-227.8 CFU/cm2). To effectively prevent the development of biofilms on the surface of container-stored water, which can lead to the recontamination of treated water, plastic storage containers should be washed within 14 days for water treated with the SIPP filter and within 3 days for water treated with the BSZ-SICG filter.
NREL Testing Erigo's and EaglePicher's Microgrid Energy Storage System |
EaglePicher's Microgrid Energy Storage System NREL researchers are testing an energy storage system for a contains three independently controllable energy storage technologies. Photo of energy storage system hardware in a laboratory Photo by Dennis Schroeder Microgrids-and effective storage systems supporting them
Risk ranking of LANL nuclear material storage containers for repackaging prioritization.
Smith, Paul H; Jordan, Hans; Hoffman, Jenifer A; Eller, P Gary; Balkey, Simon
2007-05-01
Safe handling and storage of nuclear material at U.S. Department of Energy facilities relies on the use of robust containers to prevent container breaches and subsequent worker contamination and uptake. The U.S. Department of Energy has no uniform requirements for packaging and storage of nuclear materials other than those declared excess and packaged to DOE-STD-3013-2000. This report describes a methodology for prioritizing a large inventory of nuclear material containers so that the highest risk containers are repackaged first. The methodology utilizes expert judgment to assign respirable fractions and reactivity factors to accountable levels of nuclear material at Los Alamos National Laboratory. A relative risk factor is assigned to each nuclear material container based on a calculated dose to a worker due to a failed container barrier and a calculated probability of container failure based on material reactivity and container age. This risk-based methodology is being applied at LANL to repackage the highest risk materials first and, thus, accelerate the reduction of risk to nuclear material handlers.
10. Storage and shipping container, ballistic missile, mounted on ballistic ...
10. Storage and shipping container, ballistic missile, mounted on ballistic missile trailer, view from left front - Ellsworth Air Force Base, Delta Flight, 10 mile radius around Exit 127 off Interstate 90, Interior, Jackson County, SD
11. Storage and shipping container, ballistic missile, mounted on ballistic ...
11. Storage and shipping container, ballistic missile, mounted on ballistic missile trailer, view from left side - Ellsworth Air Force Base, Delta Flight, 10 mile radius around Exit 127 off Interstate 90, Interior, Jackson County, SD
Ryazanskiy unpacks Storage Containers
2014-02-08
ISS038-E-043150 (8 Feb. 2014) --- Russian cosmonaut Sergey Ryazanskiy, Expedition 38 flight engineer, unpacks storage containers from the ISS Progress 54 cargo spacecraft, which docked to the Pirs docking compartment of the International Space Station on Feb. 5, 2014.
Al-Holy, M; Lin, M; Rasco, B
2005-03-01
The objective of this study was to investigate the effect of nisin in combination with heat or antimicrobial chemical treatments (such as lactic acid, chlorous acid, and sodium hypochlorite) on the inhibition of Listeria monocytogenes and total mesophiles in sturgeon (Acipenser transmontanus) caviar. The effects of nisin (250, 500, 750, and 1,000 IU/ml), lactic acid (1, 2, and 3%), chlorous acid (134 and 268 ppm), sodium hypochlorite (150 and 300 ppm), and heat at 60 degrees C for 3 min were evaluated for a five-strain mixture of L. monocytogenes and total mesophiles in sturgeon caviar containing 3.5% salt. Selected combinations of these antimicrobial treatments were also tested. Injured and viable L. monocytogenes cells were recovered using an overlay method. Treating caviar with > or =500 IU/ml nisin initially reduced L. monocytogenes by 2 to 2.5 log units. Chlorous acid (268 ppm) reduced L. monocytogenes from 7.7 log units to undetectable (<0.48 log units) after 4 days of storage at 4 degrees C. However, there were no synergistic effects observed for combinations of nisin (500 or 750 IU/ml) plus either lactic acid or chlorous acid. Lactic acid caused a slight reduction (approximately 1 log unit) in the microbial load during a 6-day period at 4 degrees C. Sodium hypochlorite was ineffective at the levels tested. Mild heating (60 degrees C for 3 min) with nisin synergistically reduced viable counts of L. monocytogenes and total mesophiles. No L. monocytogenes cells (<0.48 log units) were recovered from caviar treated with heat and nisin (750 IU/ml) after a storage period of 28 days at 4 degrees C.
Pipe overpack container for transuranic waste storage and shipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geinitz, R.R.; Thorp, D.T.; Rivera, M.A.
1999-12-07
A Pipe Overpack Container is described for transuranic waste storage and shipment. The system consists of a vented pipe component which is positioned in a vented, insulated 55 gallon steel drum. Both the vented pipe component and the insulated drum are capable of being secured to prevent the contents from leaving the vessel. The vented pipe component is constructed of 1/4 inch stainless steel to provide radiation shielding, thus allowing shipment having high Americium-241 content. Several Pipe Overpack Containers are then positioned in a type B, Nuclear Regulatory Commission (NRC) approved, container. In the current embodiment, a TRUPACT-II container wasmore » employed and a maximum of fourteen Pipe Overpack Containers were placed in the TRUPACT-II. The combination received NRC approval for the shipment and storage of transuranic waste.« less
Radwanski, K; Thill, M; Min, K
2014-05-01
If transfusion of older stored red cells is found to negatively affect clinical outcome, one possible alternative to shortened outdate is the use of new additive solutions (AS) that ameliorate the storage lesion. Erythro-Sol (E-Sol), a previously developed next-generation AS, has been reformulated into E-Sol 5, which is compatible with current anticoagulants and AS volumes. The effect of E-Sol 5 on red cells during storage compared to current AS has not been reported. Paired, ABO-matched whole-blood units were collected into CPD anticoagulant, pooled, split and processed into plasma and red cell units with either 110 ml of Adsol or 105 ml of E-Sol 5 within 8 h of collection. In Study 1, paired units in E-Sol 5 and Adsol were sampled on Day 0 and every 7 days up to Day 42 (n = 10). In Study 2, paired units in E-Sol 5 and Adsol were sampled only on Day 0 and Day 42 (n = 10). In Study 1, 2,3 DPG levels were maintained until Day 28 in E-Sol 5 units and Day 14 in Adsol units. ATP levels were higher in E-Sol 5 units until Day 21, after which they were comparable between the two groups. In both studies, metabolic activity was greater in E-Sol 5 units with respect to glucose consumption and lactate production. Morphology scores were higher, and haemolysis and microparticles generated were lower in E-Sol 5 vs. Adsol units. Weekly mixing of units lowered haemolysis and microparticle levels and increased potassium content on Day 42 in both additive solutions. Regardless of whether units are mixed weekly or are stored non-mixed, E-Sol 5 slows the progression of the red cell storage lesion and improves the overall in vitro quality of RBC throughout storage. © 2013 International Society of Blood Transfusion.
Estimating ecosystem carbon stocks at Redwood National and State Parks
van Mantgem, Phillip J.; Madej, Mary Ann; Seney, Joseph; Deshais, Janelle
2013-01-01
Accounting for ecosystem carbon is increasingly important for park managers. In this case study we present our efforts to estimate carbon stocks and the effects of management on carbon stocks for Redwood National and State Parks in northern California. Using currently available information, we estimate that on average these parks’ soils contain approximately 89 tons of carbon per acre (200 Mg C per ha), while vegetation contains about 130 tons C per acre (300 Mg C per ha). estoration activities at the parks (logging-road removal, second-growth forest management) were shown to initially reduce ecosystem carbon, but may provide for enhanced ecosystem carbon storage over the long term. We highlight currently available tools that could be used to estimate ecosystem carbon at other units of the National Park System.
Minimally buffered data transfers between nodes in a data communications network
Miller, Douglas R.
2015-06-23
Methods, apparatus, and products for minimally buffered data transfers between nodes in a data communications network are disclosed that include: receiving, by a messaging module on an origin node, a storage identifier, a origin data type, and a target data type, the storage identifier specifying application storage containing data, the origin data type describing a data subset contained in the origin application storage, the target data type describing an arrangement of the data subset in application storage on a target node; creating, by the messaging module, origin metadata describing the origin data type; selecting, by the messaging module from the origin application storage in dependence upon the origin metadata and the storage identifier, the data subset; and transmitting, by the messaging module to the target node, the selected data subset for storing in the target application storage in dependence upon the target data type without temporarily buffering the data subset.
Enhancing uniformity and overall quality of red cell concentrate with anaerobic storage
Yoshida, Tatsuro; Blair, Abbejane; D'Alessandro, Angelo; Nemkov, Travis; Dioguardi, Michael; Silliman, Christopher C.; Dunham, Andrew
2017-01-01
Background Recent research focused on understanding stored red blood cell (RBC) quality has demonstrated high variability in measures of RBC function and health across units. Studies have historically linked this high variability to variations in processing, storage method, and age. More recently, a large number of studies have focused on differences in donor demographics, donor iron sufficiency, and genetic predisposition of the donor to poor storage, particularly through mechanisms of accelerated oxidative damage. A study was undertaken to evaluate a potential additional source of unit to unit variation in stored RBC: the role of variable percent oxygen saturation (%SO2) levels on blood quality parameters during storage. Materials and methods %SO2 data from 492 LR-RBC/AS-3 units used for internal and external collaborative research was included in the analysis. Whole blood units were processed into red blood cells, AS-3 added, leucocyte reduced, in compliance with American Association of Blood Banks guidelines. LR-RBC/AS-3 products were subsequently analysed for %SO2 levels within 3–24 hours of phlebotomy using a co-oximeter. Separately, to evaluate the impact of pre-storage as well as increasing levels of %SO2 during storage, a pool-and-split study was performed. Four units of LR-RBC/AS-3 were split 6 ways; “as is” (control), hyperoxygenated to more than 90%, and four levels of pre-storage %SO2. The units were periodically sampled up to 42 days and analysed for %SO2, pCO2, methaemoglobin, ATP, 2,3-BPG as well as with the metabolomics workflow. Results The measured mean %SO2 in LR-RBC/AS-3 within 24 hours of collection was 45.9±17.5% with (32.7–61.0 IQR). %SO2 in all products increased to approximately 95–100% in three weeks. Measured blood quality parameters including ATP, % haemolysis, methaemoglobin, oxidised lipids, and GSH/GSSG indicated suppressed cellular metabolism and increased red cell degradation in response to higher %SO2 levels. Discussion The surprisingly high variability in starting %SO2 levels, coupled with negative impacts of high oxygen saturation on red blood cell quality indicates that oxygen levels may be an important and under-appreciated source of unit-to-unit variability in RBC quality. PMID:28263176
Enhancing uniformity and overall quality of red cell concentrate with anaerobic storage.
Yoshida, Tatsuro; Blair, Abbejane; D'alessandro, Angelo; Nemkov, Travis; Dioguardi, Michael; Silliman, Christopher C; Dunham, Andrew
2017-03-01
Recent research focused on understanding stored red blood cell (RBC) quality has demonstrated high variability in measures of RBC function and health across units. Studies have historically linked this high variability to variations in processing, storage method, and age. More recently, a large number of studies have focused on differences in donor demographics, donor iron sufficiency, and genetic predisposition of the donor to poor storage, particularly through mechanisms of accelerated oxidative damage. A study was undertaken to evaluate a potential additional source of unit to unit variation in stored RBC: the role of variable percent oxygen saturation (%SO 2 ) levels on blood quality parameters during storage. %SO 2 data from 492 LR-RBC/AS-3 units used for internal and external collaborative research was included in the analysis. Whole blood units were processed into red blood cells, AS-3 added, leucocyte reduced, in compliance with American Association of Blood Banks guidelines. LR-RBC/AS-3 products were subsequently analysed for %SO 2 levels within 3-24 hours of phlebotomy using a co-oximeter. Separately, to evaluate the impact of pre-storage as well as increasing levels of %SO 2 during storage, a pool-and-split study was performed. Four units of LR-RBC/AS-3 were split 6 ways; "as is" (control), hyperoxygenated to more than 90%, and four levels of pre-storage %SO 2 . The units were periodically sampled up to 42 days and analysed for %SO 2 , pCO 2 , methaemoglobin, ATP, 2,3-BPG as well as with the metabolomics workflow. The measured mean %SO 2 in LR-RBC/AS-3 within 24 hours of collection was 45.9±17.5% with (32.7-61.0 IQR). %SO 2 in all products increased to approximately 95-100% in three weeks. Measured blood quality parameters including ATP, % haemolysis, methaemoglobin, oxidised lipids, and GSH/GSSG indicated suppressed cellular metabolism and increased red cell degradation in response to higher %SO 2 levels. The surprisingly high variability in starting %SO 2 levels, coupled with negative impacts of high oxygen saturation on red blood cell quality indicates that oxygen levels may be an important and under-appreciated source of unit-to-unit variability in RBC quality.
Capital Provision for University Libraries in the United Kingdom--Comments on the Atkinson Report
ERIC Educational Resources Information Center
Taylor, Colin R.
1977-01-01
United Kingdom norms for libraries are reviewed and the effect they would have on Australian university libraries is examined. Focus is on book storage, future growth provision, reader places, administration, reserve storage, and special collections. (LBH)
Kitchen Units for the Classroom.
ERIC Educational Resources Information Center
Illinois Univ., Urbana. Agricultural Experiment Station.
This study is concerned with functional standards for storage of equipment, use of space, and arrangement of work centers in kitchen units for four students within a high school foods laboratory. Lists of equipment and measurements for storage areas are given for each work center. (FS)
NASA Astrophysics Data System (ADS)
Venezky, D. Y.; Rutherford, M. J.
1997-01-01
Analytical, field, and experimental evidence demonstrate that the Mount Rainier tephra layer C (2.2 ka) preserves a magma mixing event between an andesitic magma (whole rock SiO2 content of 57-60 wt %) and a dacitic magma (whole rock SiO2 content of 65±1 wt %). The end-member andesite (a mix of an injected and chamber andesite) and dacite can be characterized on the basis of the homogeneity of the matrix glass and phenocryst rim compositions. Many pumices, however, contain mixtures of the end-members. The end-member dacite contains a microlite-free matrix glass with 74-77 wt % SiO2, orthopyroxene rims of Mg57-64, clinopyroxene rims of Mg66-74, and plagioclase rim anorthite contents of An45-65. The temperature and oxygen fugacity, from Fe-Ti oxide compositions, are 930±10°C and 0.5-0.75 log units above NNO. The mixed andesite contains Mg73-84 orthopyroxene rims, Mg73-78 clinopyroxene rims, An78-84 plagioclase rims, and Mg67-74 amphibole rims. The temperature from Fe-Ti oxides, hornblendeplagioclase, and two-pyroxene geothermometry is 1060±15°C, and the oxygen fugacity is approximately one log unit above NNO for the injected andesite. The chamber andesite is estimated to be a magma with a ˜64-65 wt % SiO2 melt at 980°C and a NNO oxygen fugacity. We conclude that the andesitic and dacitic magmas are from separate magma storage regions (at >7 km and ˜2.4 km) due to differences in the bimodal whole rock, matrix glass, and phenocryst compositions and the presence or absence of stable hornblende. The time involved from the mixing event through the eruption is limited to a period of 4-5 days based on Fe-Ti oxide reequilibration, phenocryst growth rates, and hornblende breakdown. The eruption sequence is interpreted as having been initiated by an injection of the 1060±15°C andesitic magma into the ˜980°C (>7 km) andesite storage region. The mixed andesitic magma then intersected a shallow, ˜2.4 km, dacitic storage system on its way toward the surface. The eruption became more dacitic over time, and the final products some show evidence of partial reequilibration between the andesite and dacite.
40 CFR 246.200-6 - Recommended procedures: Storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Recommended procedures: Storage. 246....200-6 Recommended procedures: Storage. Among the alternatives for paper storage are on-site bailing, the use of stationary compactors, or storage in corrugated boxes or normal waste containers. Stored...
40 CFR 246.200-6 - Recommended procedures: Storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Recommended procedures: Storage. 246....200-6 Recommended procedures: Storage. Among the alternatives for paper storage are on-site bailing, the use of stationary compactors, or storage in corrugated boxes or normal waste containers. Stored...
40 CFR 246.200-6 - Recommended procedures: Storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Recommended procedures: Storage. 246....200-6 Recommended procedures: Storage. Among the alternatives for paper storage are on-site bailing, the use of stationary compactors, or storage in corrugated boxes or normal waste containers. Stored...
40 CFR 246.200-6 - Recommended procedures: Storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Recommended procedures: Storage. 246....200-6 Recommended procedures: Storage. Among the alternatives for paper storage are on-site bailing, the use of stationary compactors, or storage in corrugated boxes or normal waste containers. Stored...
40 CFR 246.200-6 - Recommended procedures: Storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Recommended procedures: Storage. 246....200-6 Recommended procedures: Storage. Among the alternatives for paper storage are on-site bailing, the use of stationary compactors, or storage in corrugated boxes or normal waste containers. Stored...
The Environmental Assessment and Management (TEAM) Guide: South Dakota Supplement
2010-02-01
Nonpermanent Bulk Pesticide Storage Containers - mobile containers positioned on or part of movable equipment, such as trucks, trailers , and tank cars...Storage Containers - containers which are not positioned on or a part of movable equipment, such as trucks, trailers , and tank cars (SDAR 12:56:01:01...premises such as houses, trailer courts, commercial buildings, and institutions (SDAR 74:53:01:01) [Citation Revised April 1998]. • Domestic Water
Red blood cell storage time and transfusion: current practice, concerns and future perspectives
García-Roa, María; del Carmen Vicente-Ayuso, María; Bobes, Alejandro M.; Pedraza, Alexandra C.; González-Fernández, Ataúlfo; Martín, María Paz; Sáez, Isabel; Seghatchian, Jerard; Gutiérrez, Laura
2017-01-01
Red blood cells (RBCs) units are the most requested transfusion product worldwide. Indications for transfusion include symptomatic anaemia, acute sickle cell crisis, and acute blood loss of more than 30% of the blood volume, with the aim of restoring tissue oxygen delivery. However, stored RBCs from donors are not a qualitative equal product, and, in many ways, this is a matter of concern in the transfusion practice. Besides donor-to-donor variation, the storage time influences the RBC unit at the qualitative level, as RBCs age in the storage bag and are exposed to the so-called storage lesion. Several studies have shown that the storage lesion leads to post-transfusion enhanced clearance, plasma transferrin saturation, nitric oxide scavenging and/or immunomodulation with potential unwanted transfusion-related clinical outcomes, such as acute lung injury or higher mortality rate. While, to date, several studies have claimed the risk or deleterious effects of “old” vs “young” RBC transfusion regimes, it is still a matter of debate, and consideration should be taken of the clinical context. Transfusion-dependent patients may benefit from transfusion with “young” RBC units, as it assures longer inter-transfusion periods, while transfusion with “old” RBC units is not itself harmful. Unbiased Omics approaches are being applied to the characterisation of RBC through storage, to better understand the (patho)physiological role of microparticles (MPs) that are found naturally, and also on stored RBC units. Perhaps RBC storage time is not an accurate surrogate for RBC quality and there is a need to establish which parameters do indeed reflect optimal efficacy and safety. A better Omics characterisation of components of “young” and “old” RBC units, including MPs, donor and recipient, might lead to the development of new therapies, including the use of engineered RBCs or MPs as cell-based drug delivering tools, or cost-effective personalised transfusion strategies. PMID:28518049
41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?
Code of Federal Regulations, 2012 CFR
2012-07-01
... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...
41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?
Code of Federal Regulations, 2010 CFR
2010-07-01
... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...
41 CFR 302-8.200 - Am I eligible for extended storage during assignment OCONUS?
Code of Federal Regulations, 2011 CFR
2011-07-01
... extended storage during assignment OCONUS? 302-8.200 Section 302-8.200 Public Contracts and Property...-ALLOWANCES FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.200 Am I eligible for extended storage during assignment OCONUS...
Secondary Containment for Underground Storage Tank Systems - 2005 Energy Policy Act
These grant guidelines implement the secondary containment provision in Section 9003(i)(1) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.
Bleiwas, Donald I.; Gambogi, Joseph
2013-01-01
Rare-earth elements (REEs) are contained in a wide range of products of economic and strategic importance to the Nation. The REEs may or may not represent a significant component of that product by mass, value, or volume; however, in many cases, the embedded REEs are critical for the device’s function. Domestic sources of primary supply and the manufacturing facilities to produce products are inadequate to meet U.S. requirements; therefore, a significant percentage of the supply of REEs and the products that contain them are imported to the United States. In 2011, mines in China produced roughly 97 percent of the world’s supply of REEs, and the country’s production of these elements will likely dominate global supply until at least 2020. Preliminary estimates of the types and amount of rare-earth elements, reported as oxides, in semimanufactured form and the amounts used for electric vehicle batteries, catalytic converters, computers, and other applications were developed to provide a perspective on the Nation’s use of these elements. The amount of rare-earth metals recovered from recycling, remanufacturing, and reuse is negligible when the tonnage of products that contain REEs deposited in landfills and retained in storage is considered. Under favorable market conditions, the recovery of REEs from obsolete products could potentially displace a portion of the supply from primary sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NNSA /NV
This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 140 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 140 consists of nine Corrective Action Sites (CASs): 05-08-01, Detonation Pits; 05-08-02, Debris Pits; 05-17-01, Hazardous Waste Accumulation Site (Buried); 05-19-01, Waste Disposal Site; 05-23-01, Gravel Gertie; 05-35-01, Burn Pit; 05-99-04, Burn Pit; 22-99-04, Radioactive Waste Dump; 23-17-01, Hazardous Waste Storage Area. All nine of these CASs are located withinmore » Areas 5, 22, and 23 of the Nevada Test Site (NTS) in Nevada, approximately 65 miles northwest of Las Vegas. This CAU is being investigated because disposed waste may be present without appropriate controls (i.e., use restrictions, adequate cover) and hazardous and/or radioactive constituents may be present or migrating at concentrations and locations that could potentially pose a threat to human health and the environment. The NTS has been used for various research and development projects including nuclear weapons testing. The CASs in CAU 140 were used for testing, material storage, waste storage, and waste disposal. A two-phase approach has been selected to collect information and generate data to satisfy needed resolution criteria and resolve the decision statements. Phase I will determine if contaminants of potential concern (COPCs) are present in concentrations exceeding preliminary action levels. This data will be evaluated at all CASs. Phase II will determine the extent of the contaminant(s) of concern (COCs). This data will only be evaluated for CASs with a COC identified during Phase I. Based on process knowledge, the COPCs for CAU 140 include volatile organics, semivolatile organics, petroleum hydrocarbons, explosive residues, herbicides, pesticides, polychlorinated biphenyls, metals, and radionuclides. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.« less
A spatial emergy model for Alachua County, Florida
NASA Astrophysics Data System (ADS)
Lambert, James David
A spatial model of the distribution of energy flows and storages in Alachua County, Florida, was created and used to analyze spatial patterns of energy transformation hierarchy in relation to spatial patterns of human settlement. Emergy, the available energy of one kind previously required directly or indirectly to make a product or service, was used as a measure of the quality of the different forms of energy flows and storages. Emergy provides a common unit of measure for comparing the productive contributions of natural processes with those of economic and social processes---it is an alternative to using money for measuring value. A geographic information system was used to create a spatial model and make maps that show the distribution and magnitude of different types of energy and emergy flows and storages occurring in one-hectare land units. Energy transformities were used to convert individual energy flows and storages into emergy units. Maps of transformities were created that reveal a clear spatial pattern of energy transformation hierarchy. The maps display patterns of widely-dispersed areas with lower transformity energy flows and storages, and smaller, centrally-located areas with higher transformities. Energy signature graphs and spatial unit transformities were used to characterize and compare the types and amounts of energy being consumed and stored according to land use classification, planning unit, and neighborhood categories. Emergy ratio maps and spatial unit ratios were created by dividing the values for specific emergy flows or storages by the values for other emergy flows or storages. Spatial context analysis was used to analyze the spatial distribution patterns of mean and maximum values for emergy flows and storages. The modeling method developed for this study is general and applicable to all types of landscapes and could be applied at any scale. An advantage of this general approach is that the results of other studies using this method will be directly comparable with the results of this study. The results and conclusions of this study reinforce the hypothesis that an urban landscape will develop a predictable spatial pattern that can be described in terms of a universal energy transformation hierarchy.
Risk, liability, and economic issues with long-term CO2 storage—A review
Anderson, Steven T.
2017-01-01
Given a scarcity of commercial-scale carbon capture and storage (CCS) projects, there is a great deal of uncertainty in the risks, liability, and their cost implications for geologic storage of carbon dioxide (CO2). The probabilities of leakage and the risk of induced seismicity could be remote, but the volume of geologic CO2 storage (GCS) projected to be necessary to have a significant impact on increasing CO2 concentrations in the atmosphere is far greater than the volumes of CO2 injected thus far. National-level estimates of the technically accessible CO2storage resource (TASR) onshore in the United States are on the order of thousands of gigatons of CO2 storage capacity, but such estimates generally assume away any pressure management issues. Pressure buildup in the storage reservoir is expected to be a primary source of risk associated with CO2 storage, and only a fraction of the theoretical TASR could be available unless the storage operator extracts the saltwater brines or other formation fluids that are already present in the geologic pore space targeted for CO2 storage. Institutions, legislation, and processes to manage the risk, liability, and economic issues with CO2 storage in the United States are beginning to emerge, but will need to progress further in order to allow a commercial-scale CO2 storage industry to develop in the country. The combination of economic tradeoffs, property rights definitions, liability issues, and risk considerations suggests that CO2 storage offshore of the United States may be more feasible than onshore, especially during the current (early) stages of industry development.
Specific storage volumes: A useful tool for CO2 storage capacity assessment
Brennan, S.T.; Burruss, R.C.
2006-01-01
Subsurface geologic strata have the potential to store billions of tons of anthropogenic CO2; therefore, geologic carbon sequestration can be an effective mitigation tool used to slow the rate at which levels of atmospheric CO2 are increasing. Oil and gas reservoirs, coal beds, and saline reservoirs can be used for CO2 storage; however, it is difficult to assess and compare the relative storage capacities of these different settings. Typically, CO2 emissions are reported in units of mass, which are not directly applicable to comparing the CO2 storage capacities of the various storage targets. However, if the emission values are recalculated to volumes per unit mass (specific volume) then the volumes of geologic reservoirs necessary to store CO2 emissions from large point sources can be estimated. The factors necessary to convert the mass of CO2 emissions to geologic storage volume (referred to here as Specific Storage Volume or 'SSV') can be reported in units of cubic meters, cubic feet, and petroleum barrels. The SSVs can be used to estimate the reservoir volume needed to store CO2 produced over the lifetime of an individual point source, and to identify CO2 storage targets of sufficient size to meet the demand from that given point source. These storage volumes also can then be projected onto the land surface to outline a representative "footprint," which marks the areal extent of storage. This footprint can be compared with the terrestrial carbon sequestration capacity of the same land area. The overall utility of this application is that the total storage capacity of any given parcel of land (from surface to basement) can be determined, and may assist in making land management decisions. ?? Springer Science+Business Media, LLC 2006.
Proceedings of the DOE chemical energy storage and hydrogen energy systems contracts review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Sessions were held on electrolysis-based hydrogen storage systems, hydrogen production, hydrogen storage systems, hydrogen storage materials, end-use applications and system studies, chemical heat pump/chemical energy storage systems, systems studies and assessment, thermochemical hydrogen production cycles, advanced production concepts, and containment materials. (LHK)
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Storage. 2008.14 Section 2008.14 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE UNITED STATES TRADE...
NASA Astrophysics Data System (ADS)
Abolghasemi, Mehran; Keshavarz, Ali; Mehrabian, Mozaffar Ali
2012-11-01
The thermal storage unit consists of two concentric cylinders where the working fluid flows through the internal cylinder and the annulus is filled with a phase change material. The system carries out a cyclic operation; each cycle consists of two processes. In the charging process the hot working fluid enters the internal cylinder and transfers heat to the phase change material. In the discharging process the cold working fluid enters the internal cylinder and absorbs heat from the phase change material. The differential equations governing the heat transfer between the two media are solved numerically. The numerical results are compared with the experimental results available in the literature. The performance of an energy storage unit is directly related to the thermal conductivity of nano-particles. The energy consumption of a residential unit whose energy is supplied by a thermal storage system can be reduced by 43 % when using nano-particles.
Design of a water electrolysis flight experiment
NASA Technical Reports Server (NTRS)
Lee, M. Gene; Grigger, David J.; Thompson, C. Dean; Cusick, Robert J.
1993-01-01
Supply of oxygen (O2) and hydrogen (H2) by electolyzing water in space will play an important role in meeting the National Aeronautics and Space Administration's (NASA's) needs and goals for future space missios. Both O2 and H2 are envisioned to be used in a variety of processes including crew life support, spacecraft propulsion, extravehicular activity, electrical power generation/storage as well as in scientific experiment and manufacturing processes. The Electrolysis Performance Improvement Concept Study (EPICS) flight experiment described herein is sponsored by NASA Headquarters as a part of the In-Space Technology Experiment Program (IN-STEP). The objective of the EPICS is to further contribute to the improvement of the SEF technology, specifially by demonstrating and validating the SFE electromechanical process in microgravity as well as investigating perrformance improvements projected possible in a microgravity environment. This paper defines the experiment objective and presents the results of the preliminary design of the EPICS. The experiment will include testing three subscale self-contained SFE units: one containing baseline components, and two units having variations in key component materials. Tests will be conducted at varying current and thermal condition.
Unitized Regenerative Fuel Cell System Gas Dryer/Humidifier Analytical Model Development
NASA Technical Reports Server (NTRS)
Burke, Kenneth A.; Jakupca, Ian
2004-01-01
A lightweight Unitized Regenerative Fuel Cell (URFC) Energy Storage System concept is being developed at the NASA Glenn Research Center (GRC). This Unitized Regenerative Fuel Cell System (URFCS) is unique in that it uses Regenerative Gas Dryers/Humidifiers (RGD/H) that are mounted on the surface of the gas storage tanks that act as the radiators for thermal control of the Unitized Regenerative Fuel Cell System (URFCS). As the gas storage tanks cool down during URFCS charging the RGD/H dry the hydrogen and oxygen gases produced by electrolysis. As the gas storage tanks heat up during URFCS discharging, the RGD/H humidify the hydrogen and oxygen gases used by the fuel cell. An analytical model was developed to simulate the URFCS RGD/H. The model is in the form of a Microsoft (registered trademark of Microsoft Corporation) Excel worksheet that allows the investigation of the RGD/H performance. Finite Element Analysis (FEA) modeling of the RGD/H and the gas storage tank wall was also done to analyze spatial temperature distribution within the RGD/H and the localized tank wall. Test results obtained from the testing of the RGD/H in a thermal vacuum environment were used to corroborate the analyses.
NASA Astrophysics Data System (ADS)
Mulyana, Cukup; Muhammad, Fajar; Saad, Aswad H.; Mariah, Riveli, Nowo
2017-03-01
Storage tank component is the most critical component in LNG regasification terminal. It has the risk of failure and accident which impacts to human health and environment. Risk assessment is conducted to detect and reduce the risk of failure in storage tank. The aim of this research is determining and calculating the probability of failure in regasification unit of LNG. In this case, the failure is caused by Boiling Liquid Expanding Vapor Explosion (BLEVE) and jet fire in LNG storage tank component. The failure probability can be determined by using Fault Tree Analysis (FTA). Besides that, the impact of heat radiation which is generated is calculated. Fault tree for BLEVE and jet fire on storage tank component has been determined and obtained with the value of failure probability for BLEVE of 5.63 × 10-19 and for jet fire of 9.57 × 10-3. The value of failure probability for jet fire is high enough and need to be reduced by customizing PID scheme of regasification LNG unit in pipeline number 1312 and unit 1. The value of failure probability after customization has been obtained of 4.22 × 10-6.
NASA Astrophysics Data System (ADS)
Thangaraj, K.; Elefsiniotis, A.; Aslam, S.; Becker, Th.; Schmid, U.; Lees, J.; Featherston, C. A.; Pullin, R.
2013-05-01
This paper describes an approach for efficiently storing the energy harvested from a thermoelectric module for powering autonomous wireless sensor nodes for aeronautical health monitoring applications. A representative temperature difference was created across a thermo electric generator (TEG) by attaching a thermal mass and a cavity containing a phase change material to one side, and a heat source (to represent the aircraft fuselage) to the other. Batteries and supercapacitors are popular choices of storage device, but neither represents the ideal solution; supercapacitors have a lower energy density than batteries and batteries have lower power density than supercapacitors. When using only a battery for storage, the runtime of a typical sensor node is typically reduced by internal impedance, high resistance and other internal losses. Supercapacitors may overcome some of these problems, but generally do not provide sufficient long-term energy to allow advanced health monitoring applications to operate over extended periods. A hybrid energy storage unit can provide both energy and power density to the wireless sensor node simultaneously. Techniques such as acoustic-ultrasonic, acoustic-emission, strain, crack wire sensor and window wireless shading require storage approaches that can provide immediate energy on demand, usually in short, high intensity bursts, and that can be sustained over long periods of time. This application requirement is considered as a significant constraint when working with battery-only and supercapacitor-only solutions and they should be able to store up-to 40-50J of energy.
NASA Astrophysics Data System (ADS)
Dewers, T. A.
2015-12-01
Multiphase flow in clay-rich sandstone reservoirs is important to enhanced oil recovery (EOR) and the geologic storage of CO2. Understanding geologic controls on pore structure allows for better identification of lithofacies that can contain, storage, and/or transmit hydrocarbons and CO2, and may result in better designs for EOR-CO2 storage. We examine three-dimensional pore structure and connectivity of sandstone samples from the Farnsworth Unit, Texas, the site of a combined EOR-CO2 storage project by the Southwest Regional Partnership on Carbon Sequestration (SWP). We employ a unique set of methods, including: robotic serial polishing and reflected-light imaging for digital pore-structure reconstruction; electron microscopy; laser scanning confocal microscopy; mercury intrusion-extrusion porosimetry; and relative permeability and capillary pressure measurements using CO2 and synthetic formation fluid. Our results link pore size distributions, topology of porosity and clay-rich phases, and spatial persistence of connected flow paths to multiphase flow behavior. The authors gratefully acknowledge the U.S. Department of Energy's National Energy Technology Laboratory for sponsoring this project through the SWP under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Buell, Gary R.; Markewich, Helaine W.
2004-01-01
U.S. Geological Survey investigations of environmental controls on carbon cycling in soils and sediments of the Mississippi River Basin (MRB), an area of 3.3 x 106 square kilometers (km2), have produced an assessment tool for estimating the storage and inventory of soil organic carbon (SOC) by using soil-characterization data from Federal, State, academic, and literature sources. The methodology is based on the linkage of site-specific SOC data (pedon data) to the soil-association map units of the U.S. Department of Agriculture State Soil Geographic (STATSGO) and Soil Survey Geographic (SSURGO) digital soil databases in a geographic information system. The collective pedon database assembled from individual sources presently contains 7,321 pedon records representing 2,581 soil series. SOC storage, in kilograms per square meter (kg/m2), is calculated for each pedon at standard depth intervals from 0 to 10, 10 to 20, 20 to 50, and 50 to 100 centimeters. The site-specific storage estimates are then regionalized to produce national-scale (STATSGO) and county-scale (SSURGO) maps of SOC to a specified depth. Based on this methodology, the mean SOC storage for the top meter of mineral soil in the MRB is approximately 10 kg/m2, and the total inventory is approximately 32.3 Pg (1 petagram = 109 metric tons). This inventory is from 2.5 to 3 percent of the estimated global mineral SOC pool.
Microbial diversity of consumption milk during processing and storage.
Porcellato, Davide; Aspholm, Marina; Skeie, Siv Borghild; Monshaugen, Marte; Brendehaug, Johanne; Mellegård, Hilde
2018-02-02
Bovine milk contains a complex microbial community that affects the quality and safety of the product. Detailed knowledge of this microbiota is, therefore, of importance for the dairy industry. In this study, the bacterial composition of consumption milk was assessed during different stages in the production line and throughout the storage in cartons by using culturing techniques and 16S rRNA marker gene sequencing. Monthly samples from two dairies were analyzed to capture the seasonal variations in the milk microbiota. Although there was a core microbiota present in milk samples from both dairies, the composition of the bacterial communities were significantly influenced by sampling month, processing stage and storage temperature. Overall, a higher abundance of operational taxonomic units (OTUs) within the order Bacillales was detected in samples of raw and pasteurized milk from the spring and summer months, while Pseudomonadales and Lactobacillales OTUs were predominant in the winter months. OTUs belonging to the order Lactobacillales, Pseudomonadales, Clostridiales and Bacillales were significantly more abundant in milk samples taken immediately after pasteurization compared to raw milk samples. During storage of milk in cartons at 4°C, the bacterial composition remained stable throughout the product shelf life, while storage at 8°C significantly increased the abundance of OTUs belonging to the genus Bacillus and the plate count levels of presumptive Bacillus cereus. The knowledge obtained in this work will be useful to the dairy industry during their quality assurance work and risk assessment practices. Copyright © 2017 Elsevier B.V. All rights reserved.
Moscoso, Hugo; Alvarado, Ivan; Hofacre, Charles L
2006-09-01
We investigated the feasibility of using FTA filter cards for the storage of bursas of Fabricius containing infectious bursal disease virus (IBDV) and for IBDV detection by reverse transcriptase (RT)-polymerase chain reaction (PCR), and characterization by restriction fragment length polymorphism (RFLP) or nucleotide sequencing. The FTA card is a cotton-based cellulose membrane containing lyophilized chemicals that lyses many types of bacteria and viruses. IBDV was inactivated upon contact with the FTA as shown by the inability of the virus to be propagated in embryonating chicken eggs. Viral RNA in minced bursas or stamped bursas could be amplified by RT-PCR (VP2 gene fragment, 248 base pairs) after storage on FTA for at least 15 days at room temperature or 8 mo at -20 C. Analytical sensitivity of the test was between 0.5-5 ng of RNA template or 5 x 10(1) mean tissue culture infective dose (TCID50)/FTA spot. Detection rate of IBDV in domestic clinical samples collected on FTA or collected by the non-FTA standard procedure was 36.7% and 41.7%, respectively, which represents 88% agreement. Detection of IBDV from FTA cards inoculated with bursal tissues in the laboratory or in the field was 36.7% and 37.1%, respectively. Detection of IBDV from FTA samples when the cards were inoculated with bursal tissues and sent through customs into the United States was 32.9%. Analysis of the amplified products showed that molecular characterization of IBDV by RFLP or nucleotide sequencing is feasible in bursas stored on FTA at 25 C for 1-3 mo or at -20 C for at least 8 mo. The use of FTA for the collection of bursal tissues and simultaneous inactivation of IBDV allows the movement of specimens within the United States and also from outside the United States in compliance with federal regulations and in a manner adequate for molecular characterization.
Mose, Kristian F; Andersen, Klaus E; Christensen, Lars Porskjaer
2012-04-01
Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber™ and IQ Ultimate™, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens. © 2012 John Wiley & Sons A/S.
Interplay of Transport and Morphology in Nanostructured Ion-Containing Polymers
NASA Astrophysics Data System (ADS)
Park, Moon Jeong
The global energy crisis and an increase in environmental pollution in the recent years have drawn the attention of the scientific community to develop innovative ways to improve energy storage and find more efficient methods of transporting the energy. Polymers containing charged species that show high ionic conductivity and good mechanical integrity are the essential components of these energy storage and transport systems. In this talk, first, I will present a fundamental understanding of the thermodynamics and transport in ion-containing block copolymers with a focus on the structure-property relationships. Tailoring the intermolecular interactions between the polymer matrix and the embedded charges appeared to be vital for controlling the transport properties. Particularly, the achievement of well-defined self-assembled morphologies with three-dimensional symmetries has proven to facilitate fast ion transport by constructing less tortuous ion-conducting pathways. Examples of attained morphologies include disorder, lamellae, gyroid, Fddd, hexagonal cylinder, body-centered cubic, face-centered cubic, and A15 phases. Second, various strategies for accessing high cation transference number as well as improved ionic conductivity from ionic-containing polymers are enclosed; (1) the inclusion of terminal ionic units as a new means to control the nanoscale morphologies and the transport efficiency of block copolymer electrolytes and (2) the addition of zwitterions that offered a polar medium close to water, and accordingly increased the charge density and ionic conductivity. The obtained knowledge on polymer electrolytes could be used in a wide range of emerging nanotechnologies such as fuel cells, lithium batteries, and electro-active actuators.
NASA Astrophysics Data System (ADS)
Ouattara, B.; Giroux, M.; Yefsah, R.; Smoragiewicz, W.; Saucier, L.; Borsa, J.; Lacroix, M.
2002-03-01
The current interest in "minimally processed foods" has attracted the attention for combination of mild treatments to improve food safety and shelf-life extention. The present study was conducted to evaluate the combined effect of gamma irradiation and incorporation of naturally occurring antimicrobial compounds on microbial and biochemistry characteristics of ground beef. Ground beef patties (23% fat ) were purchased from a local grocery store (IGA, Laval, Que., Canada) and divided into 3 separate treatment groups: (i) control (ground beef without additive), (ii) ground beef with 0.5% (w/w) ascorbic acid, and (iii) ground beef with 0.5% ascorbic acid and coated with a protein-based coating containing selected spices. Samples were irradiated at 0, 1, 2, and 3 kGy final dose at the CIC. Samples were stored at 4°C and evaluated periodically for microbial growth, total thiobarbituric reactive substances (TBARS) and free sulfydryl content. At the end of the storage period, Enterobacteriaceae, Lactic acid bacteria, Pseudomonas and Brochothrix thermosphacta were enumerated. Regardless of the treatment group, irradiation significantly ( p⩽0.05) reduced the total aerobic plate counts (APC). Irradiation doses of 1, 2, and 3 kGy produced immediate reduction of 2, 3, and 4 log units of APCs, respectively. Also, shelf-life periods were higher for ground beef samples containing food additives. Lactic acid bacteria and Brochothrix thermosphacta were more resistant to irradiation than Enterobacteriaceae and Pseudomonas. Concentration of TBARS and free sulfydryl concentrations were stabilized during post-irradiation storage for samples containing ascorbic acid and coated with the protein-based coating containing spices.
77 FR 3766 - Southwestern Gas Storage Technical Conference
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-25
... Storage Technical Conference Notice of Public Conference On December 13, 2011, the Secretary issued formal... related to natural gas storage development in the southwestern United States, to be held at the Radisson... to speak from numerous individuals representing diverse interests associated with storage development...
Development of Sausages Containing Mechanically Deboned Chicken Meat Hydrolysates.
Jin, S K; Choi, J S; Choi, Y J; Lee, S J; Lee, S Y; Hur, S J
2015-07-01
Pork meat sausages were prepared using protein hydrolysates from mechanically deboned chicken meat (MDCM). In terms of the color, compared to the controls before and after storage, the redness (a*) was significantly higher in sausages containing MDCM hydrolysates, ascorbate, and sodium erythorbate. After storage, compared to the other sausage samples, the yellowness (b*) was lower in the sausages containing ascorbate and sodium erythorbate. TBARS was not significantly different among the sausage samples before storage, whereas TBARS and DPPH radical scavenging activities were significantly higher in the sausagescontainingascorbate and sodium erythorbate, compared to the other sausage samples after 4 wk of storage. In terms of sensory evaluation, the color was significantly higher in the sausages containing MDCM hydrolysates, ascorbate, and sodium erythorbate, compared to the other sausage samples after 4 wk of storage. The "off-flavor" and overall acceptability were significantly lower in the sausages containing MDCM hydrolysates than in the other sausage samples. In most of the developed countries, meat from spent laying hens is not consumed, leading toan urgent need for effectively utilization or disposal methods. In this study, sausages were prepared using spent laying hens and protein hydrolysates from mechanically deboned chicken meat. Sausage can be made by spent laying hens hydrolysates, although overall acceptability was lower than those of other sausage samples. © 2015 Institute of Food Technologists®
DOE Office of Scientific and Technical Information (OSTI.GOV)
NNSA /NV
This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Offices's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 127 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 127 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of 12 Corrective Action Sites (CASs) located at Test Cell C; the Engine Maintenance, Assembly, and Disassembly (E-MAD) Facility; the X-Tunnel in Area 25; the Pluto Disassembly Facility; themore » Pluto Check Station; and the Port Gaston Training Facility in Area 26. These CASs include: CAS 25-01-05, Aboveground Storage Tank (AST); CAS 25-02-02, Underground Storage Tank (UST); CAS 25-23-11, Contaminated Materials; CAS 25-12-01, Boiler; CAS 25-01-06, AST; CAS 25-01-07, AST; CAS 25-02-13, UST; CAS 26- 01-01, Filter Tank (Rad) and Piping; CAS 26-01-02, Filter Tank (Rad); CAS 26-99-01, Radioactively Contaminated Filters; CAS 26-02-01, UST; CAS 26-23-01, Contaminated Liquids Spreader. Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for CAU 127 include radionuclides, metals, total petroleum hydrocarbons, volatile organic compounds, asbestos, and polychlorinated biphenyls. Additionally, beryllium may be present at some locations. The sources of potential releases are varied, but releases of contaminated liquids may have occurred and may have migrated into and impacted soil below and surrounding storage vessels at some of the CASs. Also, at several CASs, asbestos-containing materials may be present on the aboveground structures and may be friable. Exposure pathways are limited to ingestion, inhalation, and dermal contact (adsorption) of soils/sediments or liquids, or inhalation of contaminants by site workers due to disturbance of contaminated materials. Future land-use scenarios limit subsequent uses of the CASs to various nonresidential (i.e., industrial) activities. Field activities will consist of radiological walkover and screening surveys, and field-screening and collecting of both tank content and soil samples, and further sample testing as appropriate. A two-step data quality objective strategy will be followed: (1) Phase I will be to collect environmental samples for laboratory analysis to confirm the presence or absence of contaminants at concentrations exceeding preliminary action levels; and (2) Phase II will be to collect additional environmental samples for laboratory analysis to determine the extent of contamination identified in Phase I. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.« less
A Brayton cycle solar dynamic heat receiver for space
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Nordwall, H. L.; Kaufmann, K. J.; Johnson, S. D.
1989-01-01
The detailed design of a heat receiver developed to meet the requirements of the Space Station Freedom, which will be assembled and operated in low earth orbit beginning in the mid-1990's, is described. The heat receiver supplies thermal energy to a nominal 25-kW closed-Brayton-cycle power conversion unit. The receiver employs an integral thermal energy storage system utilizing the latent heat of a eutectic-salt phase-change mixture to store energy for eclipse operation. The salt is contained within a felt metal matrix which enhances heat transfer and controls the salt void distribution during solidification.
NASA Astrophysics Data System (ADS)
Pasyar, N.; Yadipour, R.; Baghban, H.
2017-07-01
The proposed design of the optical memory unit cell contains dual micro ring resonators in which the effect of lasing without inversion (LWI) in three-level nano particles doped over the optical resonators or integrators as the gain segment is used for loss compensation. Also, an on/off phase shifter based on electromagnetically induced transparency (EIT) in three-level quantum dots (QDs) has been used for data reading at requested time. Device minimizing for integrated purposes and high speed data storage are the main advantages of the optical integrator based memory.
Radiant Heat Testing of the H1224A Shipping/Storage Container
1994-05-01
re - entry vehicles caused by credible accidents during air and ground transportation. Radiant heat testing of the H1224A storage/shipping container is...inner container, and re - entry vehicle (RV) temperatures during radiant heat testing. Computer modelling can be used to predict weapon response throughout...Nomenclature RV Re - entry Vehicle midsection mass mock-up WR War Reserve STS Stockpile-to-Target Sequence NAWC Simulated H1224A container by Naval Air
Lifetime of carbon capture and storage as a climate-change mitigation technology
Szulczewski, Michael L.; MacMinn, Christopher W.; Herzog, Howard J.; Juanes, Ruben
2012-01-01
In carbon capture and storage (CCS), CO2 is captured at power plants and then injected underground into reservoirs like deep saline aquifers for long-term storage. While CCS may be critical for the continued use of fossil fuels in a carbon-constrained world, the deployment of CCS has been hindered by uncertainty in geologic storage capacities and sustainable injection rates, which has contributed to the absence of concerted government policy. Here, we clarify the potential of CCS to mitigate emissions in the United States by developing a storage-capacity supply curve that, unlike current large-scale capacity estimates, is derived from the fluid mechanics of CO2 injection and trapping and incorporates injection-rate constraints. We show that storage supply is a dynamic quantity that grows with the duration of CCS, and we interpret the lifetime of CCS as the time for which the storage supply curve exceeds the storage demand curve from CO2 production. We show that in the United States, if CO2 production from power generation continues to rise at recent rates, then CCS can store enough CO2 to stabilize emissions at current levels for at least 100 y. This result suggests that the large-scale implementation of CCS is a geologically viable climate-change mitigation option in the United States over the next century. PMID:22431639
41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?
Code of Federal Regulations, 2012 CFR
2012-07-01
... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...
41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?
Code of Federal Regulations, 2011 CFR
2011-07-01
... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...
41 CFR 302-8.106 - May I change from temporary to extended storage?
Code of Federal Regulations, 2010 CFR
2010-07-01
... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...
41 CFR 302-8.106 - May I change from temporary to extended storage?
Code of Federal Regulations, 2011 CFR
2011-07-01
... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...
41 CFR 302-8.201 - Am I entitled to reimbursement for extended storage of HHG?
Code of Federal Regulations, 2010 CFR
2010-07-01
... reimbursement for extended storage of HHG? 302-8.201 Section 302-8.201 Public Contracts and Property Management... FOR EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment Outside the Continental United States (OCONUS) § 302-8.201 Am I entitled to reimbursement for extended storage of HHG? No...
41 CFR 302-8.106 - May I change from temporary to extended storage?
Code of Federal Regulations, 2012 CFR
2012-07-01
... temporary to extended storage? 302-8.106 Section 302-8.106 Public Contracts and Property Management Federal... EXTENDED STORAGE OF HOUSEHOLD GOODS (HHG) Extended Storage During Assignment to Isolated Locations in the Continental United States (CONUS) § 302-8.106 May I change from temporary to extended storage? Yes, you may...
A New Heat Supply System of Cogeneration for the Local Community
NASA Astrophysics Data System (ADS)
Yamaguchi, Hideki; Hisazumi, Yoshinori; Asano, Hitoshi; Morita, Hikaru; Hori, Toshihiro; Matsumoto, Toshiki; Abiko, Tetsuo
In order for economically viable distributed generation systems for local communities to be widely accepted, it is essential to develop an efficient and low-cost heat supply system. For this purpose, we propose a new heat supply system which we already presented at the ICOPE-05 Chicago. The key technology for the system is to connect compact heat supply units with a heat storage function installed in all the households of the local community, such as condominiums, by a single-loop of hot water pipe. A phase change material was used for the heat supply unit as the heat storage material. However, for easier handling and reducing the cost of the unit, we have developed a new heat supply unit whose heat storage tank is made of plastic. Hot water for space heating is used as the heat storage material. Further we constructed a heat supply system for 7 lived-in households with a 5 kW gas engine and a 42 kW boiler as the heat sources. Some experiments with a heat supply unit and a heat supply system, such as for heat storage and heat supply for peak demand were conducted. Additionally, dynamic simulations of heat demand by 50 households and a COP evaluation of a new CO2 heat pump system using low-temperature exhaust gas from the gas engine were also conducted.
Thermal energy storage evaluation and life testing
NASA Astrophysics Data System (ADS)
Richter, R.
1983-01-01
Two thermal energy storage (TES) units which were built under a previous contract were tested with a Hi-Cap Vuilleumier cryogenic cooler in the facility of the Hughes Aircraft Corporation. The objective of the program was the evaluation of the behavior of the TES units as well as the determination of the temperature history of the three cold stages of the Vuilleumier cryogenic cooler during cyclic charging and discharging of the TES units. The test results have confirmed that thermal energy storage can provide the necessary thermal power to the hot cylinders of the Vuilleumier cryogenic cooler at the required operating temperatures. Thereby the continuous cooling capability of the cooler during an eclipse when no electrical power is available is being assured. The cold stage temperature amplitudes during a complete charge discharge cycle of the TES units were only about 10% of the amplitudes which were observed when the Hi-Cap Vuilleumier cryogenic cooler was operating without thermal energy storage backup in a simulated orbit of 54 minutes sun exposure and 18 minutes eclipse time. The themal conductivity of the molten thermal energy storage salt was apparently only a fraction of the thermal conductivity which had been assumed for the prediction of the upper heater temperatures. A redesign of the heater temperatures below 1480 degrees F which is now required for full charging of the TES units within 54 minutes with the present heater design.
Wider-Opening Dewar Flasks for Cryogenic Storage
NASA Technical Reports Server (NTRS)
Ruemmele, Warren P.; Manry, John; Stafford, Kristin; Bue, Grant; Krejci, John; Evernden, Bent
2010-01-01
Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.
NASA Astrophysics Data System (ADS)
Lamkin, T.; Whitney, Brian
1995-09-01
This paper describes the engineering thought process behind the failure analysis, redesign, and rework of the flight hardware for the Brilliant Eyes Thermal Storage Unit (BETSU) experiment. This experiment was designed to study the zero-g performance of 2-methylpentane as a suitable phase change material. This hydrocarbon served as the cryogenic storage medium for the BETSU experiment which was flown 04 Mar 94 on board Shuttle STS-62. Ground testing had indicated satisfactory performance of the BETSU at the 120 Kelvin design temperature. However, questions remained as to the micro-gravity performance of this unit; potential deviations in ground (1 g) versus space flight (0 g) performance, and how the unit would operate in a realistic space environment undergoing cyclical operation. The preparations and rework performed on the BETSU unit, which failed initial flight qualification, give insight and lessons learned to successfully develop and qualify a space flight experiment.
2. Missile transfer building, interior, transporter/erector on left, storage and ...
2. Missile transfer building, interior, transporter/erector on left, storage and shipping container, ballistic missile (SSCBM) containing minuteman II missile on right - Ellsworth Air Force Base, Delta Flight, Missile Roll Transfer Building, 920 Kennedy Road, Interior, Jackson County, SD
Bulk energy storage increases United States electricity system emissions.
Hittinger, Eric S; Azevedo, Inês M L
2015-03-03
Bulk energy storage is generally considered an important contributor for the transition toward a more flexible and sustainable electricity system. Although economically valuable, storage is not fundamentally a "green" technology, leading to reductions in emissions. We model the economic and emissions effects of bulk energy storage providing an energy arbitrage service. We calculate the profits under two scenarios (perfect and imperfect information about future electricity prices), and estimate the effect of bulk storage on net emissions of CO2, SO2, and NOx for 20 eGRID subregions in the United States. We find that net system CO2 emissions resulting from storage operation are nontrivial when compared to the emissions from electricity generation, ranging from 104 to 407 kg/MWh of delivered energy depending on location, storage operation mode, and assumptions regarding carbon intensity. Net NOx emissions range from -0.16 (i.e., producing net savings) to 0.49 kg/MWh, and are generally small when compared to average generation-related emissions. Net SO2 emissions from storage operation range from -0.01 to 1.7 kg/MWh, depending on location and storage operation mode.
Corrosion Testing of 304L SS 3013 Inner Container and Teardrop Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokash, Justin Charles; Hill, Mary Ann; Lillard, Scott
The Department of Energy (DOE) 3013 Standard specifies a minimum of two containers to be used for the storage of plutonium-bearing materials containing at least 30 wt.% plutonium and uranium. Three nested containers are typically used, the outer, inner, and convenience containers, shown in Figure 1. Both the outer and inner containers are sealed with a weld while the innermost convenience container must not be sealed. Lifetime of the containers is expected to be fifty years. The containers are fabricated of austenitic stainless steels (SS) due to their high corrosion resistance. Potential failure mechanisms of the storage containers have beenmore » examined by Kolman and Lillard et al.« less
Carbon storage and sequestration by trees in urban and community areas of the United States
David J. Nowak; Eric J. Greenfield; Robert E. Hoehn; Elizabeth Lapoint
2013-01-01
Carbon storage and sequestration by urban trees in the United States was quantified to assess the magnitude and role of urban forests in relation to climate change. Urban tree field data from 28 cities and 6 states were used to determine the average carbon density per unit of tree cover. These data were applied to statewide urban tree cover measurements to determine...
Radiation shielding materials and containers incorporating same
Mirsky, Steven M.; Krill, Stephen J.; Murray, Alexander P.
2005-11-01
An improved radiation shielding material and storage systems for radioactive materials incorporating the same. The PYRolytic Uranium Compound ("PYRUC") shielding material is preferably formed by heat and/or pressure treatment of a precursor material comprising microspheres of a uranium compound, such as uranium dioxide or uranium carbide, and a suitable binder. The PYRUC shielding material provides improved radiation shielding, thermal characteristic, cost and ease of use in comparison with other shielding materials. The shielding material can be used to form containment systems, container vessels, shielding structures, and containment storage areas, all of which can be used to house radioactive waste. The preferred shielding system is in the form of a container for storage, transportation, and disposal of radioactive waste. In addition, improved methods for preparing uranium dioxide and uranium carbide microspheres for use in the radiation shielding materials are also provided.
Radiation Shielding Materials and Containers Incorporating Same
Mirsky, Steven M.; Krill, Stephen J.; and Murray, Alexander P.
2005-11-01
An improved radiation shielding material and storage systems for radioactive materials incorporating the same. The PYRolytic Uranium Compound (''PYRUC'') shielding material is preferably formed by heat and/or pressure treatment of a precursor material comprising microspheres of a uranium compound, such as uranium dioxide or uranium carbide, and a suitable binder. The PYRUC shielding material provides improved radiation shielding, thermal characteristic, cost and ease of use in comparison with other shielding materials. The shielding material can be used to form containment systems, container vessels, shielding structures, and containment storage areas, all of which can be used to house radioactive waste. The preferred shielding system is in the form of a container for storage, transportation, and disposal of radioactive waste. In addition, improved methods for preparing uranium dioxide and uranium carbide microspheres for use in the radiation shielding materials are also provided.
7 CFR 51.309 - Condition after storage or transit.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...
7 CFR 51.309 - Condition after storage or transit.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...
7 CFR 51.309 - Condition after storage or transit.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Standards for Grades of Apples Condition After Storage Or Transit § 51.309... apples after they have been in storage or transit shall be considered as affecting condition and not the...
View from east to west of PAR site storage building; ...
View from east to west of PAR site storage building; formerly PAR dispensary - Stanley R. Mickelsen Safeguard Complex, Storage Building, Across street from Family Housing Units 110 & 111, Nekoma, Cavalier County, ND
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
40 CFR 265.1202 - Closure and post-closure care.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., STORAGE, AND DISPOSAL FACILITIES Hazardous Waste Munitions and Explosives Storage § 265.1202 Closure and... as long as it remains in service as a munitions or explosives magazine or storage unit. (b) If, after...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suomela, K.D.; Highsmith, R.L.; Rapuano, K.F.
1994-11-15
An Expanded Site Inspection (ESI) was conducted at the Anniston Army Depot (ANAD) Ammunition Storage Area (ASA). The objective of this ESI was to gather the information and data necessary to determine whether there is sufficient evidence of any release of contamination that would require additional investigation. The ASA contains 1,300 ammunition storage magazines and an ammunition maintenance workshop complex which includes buildings for maintenance, demilitarization, and inspection of all types of ammunition and their components. Fifteen Solid Waste Management Units (SWMUs) were the focus of the ESI, of which 11 were recommend for further investigation. The work included amore » review of historical records, field investigations, laboratory analyses, data interpretation, and report preparation. Contamination from volatile organic compounds and semi volatile organic compounds is not a major problem at the ASA. Arsenic, beryllium, cadmium, chromium, lead, mercury, nickel, silver, vanadium, zinc, explosives, and total petroleum hydrocarbons were detected above control screening values levels in one or more of the media sampled. Nitrate/nitrite and total organic carbon were also detected above control screening values in samples of groundwater, soil, and sediment from a number of SWMUs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
Upper East Fork Popular Creek Operable Unit 3 (UEFPC OU 3) is a source term OU composed of seven sites, and is located in the western portion of the Y-12 Plant. For the most part, the UEFPC OU 3 sites served unrelated purposes and are geographically removed from one another. The seven sites include the following: Building 81-10, the S-2 Site, Salvage Yard oil storage tanks, the Salvage Yard oil/solvent drum storage area, Tank Site 2063-U, the Salvage Yard drum deheader, and the Salvage Yard scrap metal storage area. All of these sites are contaminated with at least one ormore » more hazardous and/or radioactive chemicals. All sites have had some previous investigation under the Y-12 Plant RCRA Program. The work plan contains summaries of geographical, historical, operational, geological, and hydrological information specific to each OU 3 site. The potential for release of contaminants to receptors through various media is addressed, and a sampling and analysis plan is presented to obtain objectives for the remedial investigation. Proposed sampling activities are contingent upon the screening level risk assessment, which includes shallow soil sampling, soil borings, monitoring well installation, groundwater sampling, and surface water sampling. Data from the site characterization activities will be used to meet the above objectives. A Field Sampling Investigation Plan, Health and Safety Plan, and Waste Management Plan are also included in this work plan.« less
The macronutrients in human milk change after storage in various containers.
Chang, Yu-Chuan; Chen, Chao-Huei; Lin, Ming-Chih
2012-06-01
The concentrations of macronutrients in human milk can be influenced by various processes, such as storage, freezing, and thawing, that are performed by lactating working mothers and breast milk banks. We evaluated the impact of various containers on the nutrient concentrations in human milk. A total of 42 breast milk samples from 18 healthy lactating mothers were collected. A baseline macronutrient concentration was determined for each sample. Then, the breast milk samples were divided and stored in nine different commercial milk containers. After freezing at -20°C for 2 days, the milk samples were thawed and analyzed again. A midinfrared human milk analyzer (HMA) was used to measure the protein, fat, and carbohydrate contents. There was a significant decrease in the fat content following the storage, freezing, and thawing processes, ranging from 0.27-0.30 g/dL (p=0.02), but no significant decrease in energy content (p=0.069) was noted in the nine different containers. There were statistically significant increases in protein and carbohydrate concentrations in all containers (p=0.021 and 0.001, respectively), however there were no significant differences between the containers in terms of fat, protein, carbohydrate, or energy contents. Human milk, when subjected to storage, freezing, and thawing processes, demonstrated a significant decrease in fat content (up to 9% reduction) in various containers. It is better for infants to receive milk directly from the mother via breastfeeding. More studies are warranted to evaluate the effects of milk storage on infant growth and development. Copyright © 2012. Published by Elsevier B.V.
Operator Exposure to Hydrogen Sulfide from Dairy Manure Storages Containing Gypsum Bedding.
Fabian-Wheeler, Eileen E; Hile, Michael L; Murphy, Dennis J; Hill, Davis E; Meinen, Robert; Brandt, Robin C; Elliott, Hershel A; Hofstetter, Daniel
2017-01-26
Dairy manure storages containing gypsum-based bedding have been linked anecdotally with injury and death due to presumed dangerous levels of gases released. Recycled gypsum products are used as a cost-effective bedding alternative to improve animal welfare and provide agronomic benefits to manure recycled back to the land. Sulfur contained in gypsum (calcium sulfate) can contribute to hydrogen sulfide (H2S) gas formation under the anaerobic storage conditions typical of dairy manure slurry. Disturbance of stored manure during agitation releases a burst of volatile gases. On-farm monitoring was conducted to document conditions during manure storage agitation relative to gas concentration and operator safety. One objective was to document operator exposure to H2S levels; therefore, each operator wore a personal gas monitor while performing tasks associated with manure storage agitation. Data from three dairy bedding management categories on ten farms were compared: (1) traditional organic bedding, (2) gypsum bedding, and (3) gypsum bedding plus a manure additive thought to reduce H2S formation and/or release. Portable meters placed around the perimeter of dairy manure storages recorded H2S concentrations prior to and during 19 agitation events. Results show that farms using gypsum bedding produced higher H2S concentrations during manure storage agitation than farms using traditional bedding. In most cases, gypsum-containing manure storages produced H2S levels above recognized safe thresholds for both livestock and humans. Farm operators were most at risk during activities in close proximity to the manure storage during agitation, and conditions 10 m away from the storage were above the 20 ppm H2S threshold on some farms using gypsum bedding. Although H2S concentrations rose to dangerous levels, only two of 18 operators were exposed to >50 ppm H2S during the first 60 min of manure storage agitation. Operators who are aware of the risk of high H2S concentrations near gypsum-laden manure storages can reduce their exposure risk by working upwind and away from the H2S plume within a closed tractor cab. Copyright© by the American Society of Agricultural Engineers.
Space Station thermal storage/refrigeration system research and development
NASA Astrophysics Data System (ADS)
Dean, W. G.; Karu, Z. S.
1993-02-01
Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).
Space Station thermal storage/refrigeration system research and development
NASA Technical Reports Server (NTRS)
Dean, W. G.; Karu, Z. S.
1993-01-01
Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a single centralized radiator system. As per the scope of work of this task, the applicability of refrigeration system tailored to meet the specialized requirements of storage of food and biological samples was investigated. The issues addressed were the anticipated power consumption and feasible designs and cycles for meeting specific storage requirements. Further, development issues were assessed related to the operation of vapor compression systems in micro-gravity addressing separation of vapor and liquid phases (via capillary systems).
Velocity Model for CO2 Sequestration in the Southeastern United States Atlantic Continental Margin
NASA Astrophysics Data System (ADS)
Ollmann, J.; Knapp, C. C.; Almutairi, K.; Almayahi, D.; Knapp, J. H.
2017-12-01
The sequestration of carbon dioxide (CO2) is emerging as a major player in offsetting anthropogenic greenhouse gas emissions. With 40% of the United States' anthropogenic CO2 emissions originating in the southeast, characterizing potential CO2 sequestration sites is vital to reducing the United States' emissions. The goal of this research project, funded by the Department of Energy (DOE), is to estimate the CO2 storage potential for the Southeastern United States Atlantic Continental Margin. Previous studies find storage potential in the Atlantic continental margin. Up to 16 Gt and 175 Gt of storage potential are estimated for the Upper Cretaceous and Lower Cretaceous formations, respectively. Considering 2.12 Mt of CO2 are emitted per year by the United States, substantial storage potential is present in the Southeastern United States Atlantic Continental Margin. In order to produce a time-depth relationship, a velocity model must be constructed. This velocity model is created using previously collected seismic reflection, refraction, and well data in the study area. Seismic reflection horizons were extrapolated using well log data from the COST GE-1 well. An interpolated seismic section was created using these seismic horizons. A velocity model will be made using P-wave velocities from seismic reflection data. Once the time-depth conversion is complete, the depths of stratigraphic units in the seismic refraction data will be compared to the newly assigned depths of the seismic horizons. With a lack of well control in the study area, the addition of stratigraphic unit depths from 171 seismic refraction recording stations provides adequate data to tie to the depths of picked seismic horizons. Using this velocity model, the seismic reflection data can be presented in depth in order to estimate the thickness and storage potential of CO2 reservoirs in the Southeastern United States Atlantic Continental Margin.
Tyurin and Ryazanskiy unpacks Storage Containers
2014-02-08
ISS038-E-043144 (8 Feb. 2014) --- Russian cosmonauts Mikhail Tyurin and Sergey Ryazanskiy (background), both Expedition 38 flight engineers, unpack storage containers from the ISS Progress 54 cargo spacecraft, which docked to the Pirs docking compartment of the International Space Station on Feb. 5, 2014.
Tyurin and Ryazanskiy unpacks Storage Containers
2014-02-08
ISS038-E-043146 (8 Feb. 2014) --- Russian cosmonauts Mikhail Tyurin and Sergey Ryazanskiy (background), both Expedition 38 flight engineers, unpack storage containers from the ISS Progress 54 cargo spacecraft, which docked to the Pirs docking compartment of the International Space Station on Feb. 5, 2014.
Soares-da-Silva, Joelma; Ibiapina, Sebastiana Silva; Bezerra, Juliana Maria Trindade; Tadei, Wanderli Pedro; Pinheiro, Valéria Cristina Soares
2012-01-01
Dengue is a serious public health problem worldwide, with cases reported annually in tropical and subtropical regions. Aedes aegypti (Linnaeus, 1762), the main vector of dengue, is a domiciliary species with high dispersal and survival capacities and can use various artificial containers as breeding sites. We assessed potential container breeding sites of A. aegypti in the municipality of Caxias, Maranhão, Brazil. In the initial phase, we analyzed 900 properties in 3 neighborhoods during the dry and rainy seasons (August-October 2005 and February-April 2006, respectively). During the second sampling period, September 2006-August 2007, we used 5 assessment cycles for 300 properties in a single neighborhood. During the dry and rainy seasons, water-storage containers comprised 55.7% (n = 1,970) and 48.5% (n = 1,836) of the total containers inspected, and showed the highest productivity of immature A. aegypti; we found 23.7 and 106.1 individuals/container, respectively, in peridomicile sites. In intradomicile sites, water-storage containers were also the most important breeding sites with 86.4% (n = 973) and 85.6% (n = 900) of all containers and a mean of 7.9 and 108.3 individuals/container in the dry and rainy seaso-October 2006 (1,342). The highest number of positives (70) was recorded in May, mostly (94%) in storage containers. Storage containers are the principal and most productive A. aegypti breeding sites and are a major contributing factor to the maintenance of this vector in Caxias.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLaren, Joyce A; Gagnon, Pieter J; Mullendore, Seth
This paper presents the first publicly available comprehensive survey of the magnitude of demand charges for commercial customers across the United States -- a key predictor of the financial performance of behind-the-meter battery storage systems. Notably, the analysis estimates that there are nearly 5 million commercial customers in the United States who can subscribe to retail electricity tariffs that have demand charges in excess of $15 per kilowatt (kW), over a quarter of the 18 million commercial customers in total in the United States. While the economic viability of installing battery energy storage must be determined on a case-by-case basis,more » high demand charges are often cited as a critical factor in battery project economics. Increasing use of demand charges in utility tariffs and anticipated future declines in storage costs will only serve to unlock additional markets and strengthen existing ones.« less
NASA Astrophysics Data System (ADS)
Hedayat, A.; Cartagena, W.; Majumdar, A. K.; LeClair, A. C.
2016-03-01
NASA's future missions may require long-term storage and transfer of cryogenic propellants. The Engineering Development Unit (EDU), a NASA in-house effort supported by both Marshall Space Flight Center (MSFC) and Glenn Research Center, is a cryogenic fluid management (CFM) test article that primarily serves as a manufacturing pathfinder and a risk reduction task for a future CFM payload. The EDU test article comprises a flight-like tank, internal components, insulation, and attachment struts. The EDU is designed to perform integrated passive thermal control performance testing with liquid hydrogen (LH2) in a test-like vacuum environment. A series of tests, with LH2 as a testing fluid, was conducted at Test Stand 300 at MSFC during the summer of 2014. The objective of this effort was to develop a thermal/fluid model for evaluating the thermodynamic behavior of the EDU tank during the chill and fill processes. The Generalized Fluid System Simulation Program, an MSFC in-house general-purpose computer program for flow network analysis, was utilized to model and simulate the chill and fill portion of the testing. The model contained the LH2 supply source, feed system, EDU tank, and vent system. The test setup, modeling description, and comparison of model predictions with the test data are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregson, Michael Warren; Mo, Tin; Sorenson, Ken Bryce
The authors provide a detailed overview of an on-going, multinational test program that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolized materials plus volatilized fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy-density device. The program participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research program. Sandia National Laboratoriesmore » has the lead role for conducting this research program; test program support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. The authors provide a summary of the overall, multiphase test design and a description of all explosive containment and aerosol collection test components used. They focus on the recently initiated tests on 'surrogate' spent fuel, unirradiated depleted uranium oxide and forthcoming actual spent fuel tests, and briefly summarize similar results from completed surrogate tests that used non-radioactive, sintered cerium oxide ceramic pellets in test rods.« less
BRIC-100VC Biological Research in Canisters (BRIC)-100VC
NASA Technical Reports Server (NTRS)
Richards, Stephanie E.; Levine, Howard G. (Compiler); Romero, Vergel
2016-01-01
The Biological Research in Canisters (BRIC) is an anodized-aluminum cylinder used to provide passive stowage for investigations of the effects of space flight on small specimens. The BRIC 100 mm petri dish vacuum containment unit (BRIC-100VC) has supported Dugesia japonica (flatworm) within spring under normal atmospheric conditions for 29 days in space and Hemerocallis lilioasphodelus L. (daylily) somatic embryo development within a 5% CO2 gaseous environment for 4.5 months in space. BRIC-100VC is a completely sealed, anodized-aluminum cylinder (Fig. 1) providing containment and structural support of the experimental specimens. The top and bottom lids of the canister include rapid disconnect valves for filling the canister with selected gases. These specialized valves allow for specific atmospheric containment within the canister, providing a gaseous environment defined by the investigator. Additionally, the top lid has been designed with a toggle latch and O-ring assembly allowing for prompt sealing and removal of the lid. The outside dimensions of the BRIC-100VC canisters are 16.0 cm (height) x 11.4 cm (outside diameter). The lower portion of the canister has been equipped with sufficient storage space for passive temperature and relative humidity data loggers. The BRIC- 100VC canister has been optimized to accommodate standard 100 mm laboratory petri dishes or 50 mL conical tubes. Depending on storage orientation, up to 6 or 9 canisters have been flown within an International Space Station (ISS) stowage locker.
2007-02-01
The Food and Drug Administration (FDA) is classifying a cord blood processing system and storage container into class II (special controls). The special control that will apply to this device is the guidance document entitled "Class II Special Controls Guidance Document: Cord Blood Processing System and Storage Container." FDA is classifying this device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of this device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sacuta, Norm; Young, Aleana; Worth, Kyle
2015-12-22
The IEAGHG Weyburn-Midale CO₂ Monitoring and Storage Project (WMP) began in 2000 with the first four years of research that confirmed the suitability of the containment complex of the Weyburn oil field in southeastern Saskatchewan as a storage location for CO₂ injected as part of enhanced oil recovery (EOR) operations. The first half of this report covers research conducted from 2010 to 2012, under the funding of the United States Department of Energy (contract DEFE0002697), the Government of Canada, and various other governmental and industry sponsors. The work includes more in-depth analysis of various components of a measurement, monitoring andmore » verification (MMV) program through investigation of data on site characterization and geological integrity, wellbore integrity, storage monitoring (geophysical and geochemical), and performance/risk assessment. These results then led to the development of a Best Practices Manual (BPM) providing oilfield and project operators with guidance on CO₂ storage and CO₂-EOR. In 2013, the USDOE and Government of Saskatchewan exercised an optional phase of the same project to further develop and deploy applied research tools, technologies, and methodologies to the data and research at Weyburn with the aim of assisting regulators and operators in transitioning CO₂-EOR operations into permanent storage. This work, detailed in the second half of this report, involves seven targeted research projects – evaluating the minimum dataset for confirming secure storage; additional overburden monitoring; passive seismic monitoring; history-matched modelling; developing proper wellbore design; casing corrosion evaluation; and assessment of post CO₂-injected core samples. The results from the final and optional phases of the Weyburn-Midale Project confirm the suitability of CO₂-EOR fields for the injection of CO₂, and further, highlight the necessary MMV and follow-up monitoring required for these operations to be considered permanent storage.« less
Organizing and Typing Persistent Objects Within an Object-Oriented Framework
NASA Technical Reports Server (NTRS)
Madany, Peter W.; Campbell, Roy H.
1991-01-01
Conventional operating systems provide little or no direct support for the services required for an efficient persistent object system implementation. We have built a persistent object scheme using a customization and extension of an object-oriented operating system called Choices. Choices includes a framework for the storage of persistent data that is suited to the construction of both conventional file system and persistent object system. In this paper we describe three areas in which persistent object support differs from file system support: storage organization, storage management, and typing. Persistent object systems must support various sizes of objects efficiently. Customizable containers, which are themselves persistent objects and can be nested, support a wide range of object sizes in Choices. Collections of persistent objects that are accessed as an aggregate and collections of light-weight persistent objects can be clustered in containers that are nested within containers for larger objects. Automated garbage collection schemes are added to storage management and have a major impact on persistent object applications. The Choices persistent object store provides extensible sets of persistent object types. The store contains not only the data for persistent objects but also the names of the classes to which they belong and the code for the operation of the classes. Besides presenting persistent object storage organization, storage management, and typing, this paper discusses how persistent objects are named and used within the Choices persistent data/file system framework.
Container for reprocessing and permanent storage of spent nuclear fuel assemblies
Forsberg, Charles W.
1992-01-01
A single canister process container for reprocessing and permanent storage of spent nuclear fuel assemblies comprising zirconium-based cladding and fuel, which process container comprises a collapsible container, having side walls that are made of a high temperature alloy and an array of collapsible support means wherein the container is capable of withstanding temperature necessary to oxidize the zirconium-based cladding and having sufficient ductility to maintain integrity when collapsed under pressure. The support means is also capable of maintaining their integrity at temperature necessary to oxide the zirconium-based cladding. The process container also has means to introduce and remove fluids to and from the container.
Storage, transmission and distribution of hydrogen
NASA Technical Reports Server (NTRS)
Kelley, J. H.; Hagler, R., Jr.
1979-01-01
Current practices and future requirements for the storage, transmission and distribution of hydrogen are reviewed in order to identify inadequacies to be corrected before hydrogen can achieve its full potential as a substitute for fossil fuels. Consideration is given to the storage of hydrogen in underground solution-mined salt caverns, portable high-pressure containers and dewars, pressure vessels and aquifers and as metal hydrides, hydrogen transmission in evacuated double-walled insulated containers and by pipeline, and distribution by truck and internal distribution networks. Areas for the improvement of these techniques are indicated, and these technological deficiencies, including materials development, low-cost storage and transmission methods, low-cost, long-life metal hydrides and novel methods for hydrogen storage, are presented as challenges for research and development.
The Need for Integrating the Back End of the Nuclear Fuel Cycle in the United States of America
Bonano, Evaristo J.; Kalinina, Elena A.; Swift, Peter N.
2018-02-26
Current practice for commercial spent nuclear fuel management in the United States of America (US) includes storage of spent fuel in both pools and dry storage cask systems at nuclear power plants. Most storage pools are filled to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler fuel from pools into dry storage. In the absence of a repository that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 134,000 metric tons of spent fuel in dry storage by mid-centurymore » when the last plants in the current reactor fleet are decommissioned. Current designs for storage systems rely on large dual-purpose (storage and transportation) canisters that are not optimized for disposal. Various options exist in the US for improving integration of management practices across the entire back end of the nuclear fuel cycle.« less
The Need for Integrating the Back End of the Nuclear Fuel Cycle in the United States of America
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonano, Evaristo J.; Kalinina, Elena A.; Swift, Peter N.
Current practice for commercial spent nuclear fuel management in the United States of America (US) includes storage of spent fuel in both pools and dry storage cask systems at nuclear power plants. Most storage pools are filled to their operational capacity, and management of the approximately 2,200 metric tons of spent fuel newly discharged each year requires transferring older and cooler fuel from pools into dry storage. In the absence of a repository that can accept spent fuel for permanent disposal, projections indicate that the US will have approximately 134,000 metric tons of spent fuel in dry storage by mid-centurymore » when the last plants in the current reactor fleet are decommissioned. Current designs for storage systems rely on large dual-purpose (storage and transportation) canisters that are not optimized for disposal. Various options exist in the US for improving integration of management practices across the entire back end of the nuclear fuel cycle.« less
7 CFR 58.154 - Refrigerated storage.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Refrigerated storage. 58.154 Section 58.154... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Storage of Finished Product § 58.154 Refrigerated storage. Finished product in containers subject to such conditions that will...
7 CFR 58.154 - Refrigerated storage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Refrigerated storage. 58.154 Section 58.154... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Storage of Finished Product § 58.154 Refrigerated storage. Finished product in containers subject to such conditions that will...
7 CFR 58.154 - Refrigerated storage.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Refrigerated storage. 58.154 Section 58.154... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Storage of Finished Product § 58.154 Refrigerated storage. Finished product in containers subject to such conditions that will...
7 CFR 58.154 - Refrigerated storage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Refrigerated storage. 58.154 Section 58.154... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Storage of Finished Product § 58.154 Refrigerated storage. Finished product in containers subject to such conditions that will...
7 CFR 58.154 - Refrigerated storage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Refrigerated storage. 58.154 Section 58.154... Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Storage of Finished Product § 58.154 Refrigerated storage. Finished product in containers subject to such conditions that will...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2014 CFR
2014-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2014-01-01 2014-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2011 CFR
2011-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2011-01-01 2011-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2012 CFR
2012-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2012-01-01 2012-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2013 CFR
2013-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2013-01-01 2013-01-01 false Real property containing underground storage tanks...
Code of Federal Regulations, 2013 CFR
2013-07-01
... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...
Code of Federal Regulations, 2010 CFR
2010-07-01
... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...
Code of Federal Regulations, 2011 CFR
2011-07-01
... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...
Code of Federal Regulations, 2012 CFR
2012-07-01
... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...
Onboard System Evaluation of Rotors Vibration, Engines (OBSERVE) monitoring System
1992-07-01
consists of a Data Acquisiiton Unit (DAU), Control and Display Unit ( CADU ), Universal Tracking Devices (UTD), Remote Cockpit Display (RCD) and a PC...and Display Unit ( CADU ) - The CADU provides data storage and a graphical user interface neccesary to display both the measured data and diagnostic...information. The CADU has an interface to a Credit Card Memory (CCM) which operates similar to a disk drive, allowing the storage of data and programs. The
Storage of Medical Unit Prepositioned War Reserve Materiel
1978-01-01
PROJECT REPORT JANUARY 1978 DARCOM 5-77 STORAGE OF MEDICAL UNIT PREPOSITIONED m WAR RESERVE MATERIEL DTIC I 1is dcurtent hais lbe-i approved J JU N...ERIZATION CENTER 8030 TOITHANNA ARMY BEPOT 8030 1 OITNANNA, PENNSYLVANIA 11466 81 6 03 048 ABSTRACT .Army Medical Department (AMEDD) war reserve stocks are...presently commingled with mission stocks throughout the world . In case of mobilization, these stocks must be selected, assembled into units, and
2015-01-01
Tandem mass spectrometry for the multiplex and quantitative analysis of enzyme activities in dried blood spots on newborn screening cards has emerged as a powerful technique for early assessment of lysosomal storage diseases. Here we report the design and process-scale synthesis of substrates for the enzymes α-l-iduronidase, iduronate-2-sulfatase, and N-acetylgalactosamine-4-sulfatase that are used for newborn screening of mucopolysaccharidosis types I, II, and VI. The products contain a bisamide unit that is hypothesized to readily protonate in the gas phase, which improves detection sensitivity by tandem mass spectrometry. The products contain a benzoyl group, which provides a useful site for inexpensive deuteration, thus facilitating the preparation of internal standards for the accurate quantification of enzymatic products. Finally, the reagents are designed with ease of synthesis in mind, thus permitting scale-up preparation to support worldwide newborn screening of lysosomal storage diseases. The new reagents provide the most sensitive assay for the three lysosomal enzymes reported to date as shown by their performance in reactions using dried blood spots as the enzyme source. Also, the ratio of assay signal to that measured in the absence of blood (background) is superior to all previously reported mucopolysaccharidosis types I, II, and VI assays. PMID:24694010
40 CFR 63.1360 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...
40 CFR 63.1360 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...
40 CFR 63.1360 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...
40 CFR 63.1360 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vessel and does not have an intervening storage vessel. If two or more PAI process units have the same.... If two or more PAI process units have the same input to or output from the storage vessel in the tank... hours during the calendar year. (e) Applicability of this subpart except during periods of startup...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-16
..., and wine storage units for export and the domestic market. Components and materials sourced from... entry procedures that applies to refrigerators, freezers, and wine storage units (duty rate--free) for... realize logistical benefits through the use of weekly customs entry procedures. Customs duties also could...
NASA Astrophysics Data System (ADS)
Johnson, E. R.
2015-12-01
Island arc volcanoes can become submarine during cataclysmal caldera collapse. The passage of a volcanic vent from atmospheric to under water environment involves complex modifications of the eruption style and subsequent transport of the pyroclasts. Here, we use FTIR measurements of the volatile contents of glass and melt inclusions in the juvenile pumice clasts in the Sumisu basin and its surroundings (Izu-Bonin arc) to investigate changes in eruption depths, magma storage and degassing over time. This study is based on legacy cores from ODP 126, where numerous unconsolidated (<65 ka), extremely thick (few m to >250 m), massive to normally graded pumice lapilli-tuffs were recovered over four cores (788C, 790A, 790B and 791A). Glass and clast geochemistry indicate the submarine Sumisu caldera as the source of several of these pumice lapilli-tuffs. Glass chips and melt inclusions from these samples were analyzed using FTIR for H2O and CO2 contents. Glass chips record variable H2O contents; most chips contain 0.6-1.6 wt% H2O, corresponding to eruption depths of 320-2100 mbsl. Variations in glass H2O and pressure estimates suggest that edifice collapse occurred prior-to or during eruption of the oldest of these samples, and that the edifice may have subsequently grown over time. Sanidine-hosted melt inclusions from two units record variably degassed but H2O-rich melts (1.1-5.6 wt% H2O). The lowest H2O contents overlap with glass chips, consistent with degassing and crystallization of melts until eruption, and the highest H2O contents suggest that large amounts of degassing accompanied likely explosive eruptions. Most inclusions, from both units, contain 2-4 wt% H2O, which further indicates that the magmas crystallized at pressures of ~50-100 MPa, or depths ~400-2800 m below the seafloor. Further glass and melt inclusion analyses, including major element compositions, will elucidate changes in magma storage, degassing and evolution over time.
Hunsicker, Oliver; Hessler, Katarina; Krannich, Alexander; Boemke, Willehad; Braicu, Ioana; Sehouli, Jalid; Meyer, Oliver; Pruß, Axel; Spies, Claudia; Feldheiser, Aarne
2018-04-17
After transfusion of senescent red blood cells (RBCs) a considerable fraction is rapidly cleared from the recipients' circulation. Thus, transfusion of senescent RBCs may be less effective in terms of increasing hemoglobin concentration (cHb) after transfusion. Data were retrospectively obtained in patients who underwent major abdominal surgery between 2006 and 2012. Patients were eligible if they received RBCs during surgery and had at least two arterial blood gas analyses performed. The primary endpoint was the increase of recipients' cHb related to the transfusion of 1 unit of RBCs with respect to different storage periods. Four storage periods were defined according to the distribution of RBC storage of the study population. General estimating equation was used for calculation of the primary endpoint and to adjust for confounding variables. A total of 598 arterial blood gas samples from 120 patients, receiving 429 RBC units, were analyzed. Mean (±SD) RBC storage was 21 (±9) days. RBC storage duration and the increase in recipients' cHb were inversely and gradually related; that is, the older the RBCs, the lower the increase in the recipients' cHb after transfusion (storage < 12 days, ΔcHb per unit RBCs +0.82 [95% confidence interval, 0.42-1.21] g/dL, p < 0.01; storage 12-20 days, +0.66 [0.46-0.86] g/dL, p < 0.01; storage 21-29 days, +0.56 [0.33-0.79] g/dL, p < 0.01; storage ≥30 days, +0.39 [0.07 to 0.71] g/dL, p = 0.02). Transfusion of senescent RBCs increased cHb less effectively than transfusion of fresher RBCs. © 2018 AABB.
Alshalani, Abdulrahman; Howell, Anita; Acker, Jason P
2018-02-01
Several factors have been proposed to influence the red blood cell storage lesion including storage duration, blood component manufacturing methodology, and donor characteristics [1,18]. The objectives of this study were to determine the impact of manufacturing method and donor characteristics on water permeability and membrane quality parameters. Red blood cell units were obtained from volunteer blood donors and grouped according to the manufacturing method and donor characteristics of sex and age. Membrane water permeability and membrane quality parameters, including deformability, hemolysis, osmotic fragility, hematologic indices, supernatant potassium, and supernatant sodium, were determined on day 5 ± 2, day 21, and day 42. Regression analysis was applied to evaluate the contribution of storage duration, manufacturing method, and donor characteristics on storage lesion. This study found that units processed using a whole blood filtration manufacturing method exhibited significantly higher membrane water permeability throughout storage compared to units manufactured using red cell filtration. Additionally, significant differences in hemolysis, supernatant potassium, and supernatant sodium were seen between manufacturing methods, however there were no significance differences between donor age and sex groups. Findings of this study suggest that the membrane-related storage lesion is initiated prior to the first day of storage with contributions by both blood manufacturing process and donor variability. The findings of this work highlight the importance of characterizing membrane water permeability during storage as it can be a predictor of the biophysical and chemical changes that affect the quality of stored red blood cells during hypothermic storage. Copyright © 2017 Elsevier Inc. All rights reserved.
Hydrological analysis of single and dual storage systems for stormwater harvesting.
Brodie, I M
2008-01-01
As stormwater flows are intermittent, the requirement to store urban runoff is important to the design of a stormwater re-use scheme. In many urban areas, the space available to provide storage is limited and thus the need to optimise the storage volume becomes critical. This paper will highlight the advantages and disadvantages of two different approaches of providing storage: 1) a single shallow storage (0.5 m depth) in which stormwater capture and a balanced release to supply users is provided by the one unit; and 2) a dual system in which the functions of stormwater capture and supply release are provided by two separate deeper storage units (2 m depth). The comparison between the two strategies is supported by water balance modelling assessing the supply reliability and storage volume requirements for both options. Above a critical volumetric capacity, the supply yield of a dual storage system is higher than that from a single storage of equal volume mainly because of a smaller assumed footprint. The single storage exhibited greater evaporation loss and is more susceptible to algae blooms due to long water residence times. Results of the comparison provide guidance to the design of more efficient storages associated with stormwater harvesting systems. Copyright IWA Publishing 2008.
32 CFR 855.16 - Parking and storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 6 2011-07-01 2011-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...
32 CFR 855.16 - Parking and storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 6 2010-07-01 2010-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...
32 CFR 855.16 - Parking and storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 6 2013-07-01 2013-07-01 false Parking and storage. 855.16 Section 855.16... OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.16 Parking and storage. The... designated representative but should be linked to the purpose of use authorized. Parking and storage may be...
Blood banking-induced alteration of red blood cell oxygen release ability
Li, Yaojin; Xiong, Yanlian; Wang, Ruofeng; Tang, Fuzhou; Wang, Xiang
2016-01-01
Background Current blood banking procedures may not fully preserve red blood cell (RBC) function during storage, contributing to the decrease of RBC oxygen release ability. This study was undertaken to evaluate the impact of routine cold storage on RBC oxygen release ability. Materials and methods RBC units were collected from healthy donors and each unit was split into two parts (whole blood and suspended RBC) to exclude possible donor variability. Oxygen dissociation measurements were performed on blood units stored at 4 °C during a 5-week period. 2,3-diphosphoglycerate levels and fluorescent micrographs of erythrocyte band 3 were also analysed. Results P50 and oxygen release capacity decreased rapidly during the first 3 weeks, and then did not change significantly. In contrast, the kinetic properties (PO2-t curve and T*50) of oxygen release changed slowly during the first 3 weeks of storage, but then decreased significantly in the last 2 weeks. 2,3-diphosphoglycerate decreased quickly during the first 3 weeks of storage to almost undetectable levels. Band 3 aggregated significantly during the last 2 weeks of storage. Discussion RBC oxygen release ability appears to be sensitive to routine cold storage. The thermodynamic characteristics of RBC oxygen release ability changed mainly in the first 3 weeks of storage, due to the decrease of 2,3-diphosphoglycerate, whereas the kinetic characteristics of RBC oxygen release ability decreased significantly at the end of storage, probably affected by alterations of band 3. PMID:26674824
Blood banking-induced alteration of red blood cell oxygen release ability.
Li, Yaojin; Xiong, Yanlian; Wang, Ruofeng; Tang, Fuzhou; Wang, Xiang
2016-05-01
Current blood banking procedures may not fully preserve red blood cell (RBC) function during storage, contributing to the decrease of RBC oxygen release ability. This study was undertaken to evaluate the impact of routine cold storage on RBC oxygen release ability. RBC units were collected from healthy donors and each unit was split into two parts (whole blood and suspended RBC) to exclude possible donor variability. Oxygen dissociation measurements were performed on blood units stored at 4 °C during a 5-week period. 2,3-diphosphoglycerate levels and fluorescent micrographs of erythrocyte band 3 were also analysed. P50 and oxygen release capacity decreased rapidly during the first 3 weeks, and then did not change significantly. In contrast, the kinetic properties (PO2-t curve and T*50) of oxygen release changed slowly during the first 3 weeks of storage, but then decreased significantly in the last 2 weeks. 2,3-diphosphoglycerate decreased quickly during the first 3 weeks of storage to almost undetectable levels. Band 3 aggregated significantly during the last 2 weeks of storage. RBC oxygen release ability appears to be sensitive to routine cold storage. The thermodynamic characteristics of RBC oxygen release ability changed mainly in the first 3 weeks of storage, due to the decrease of 2,3-diphosphoglycerate, whereas the kinetic characteristics of RBC oxygen release ability decreased significantly at the end of storage, probably affected by alterations of band 3.
Method and apparatus for operating an improved thermocline storage unit
Copeland, R.J.
1982-09-30
A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer there between. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.
Method and apparatus for operating an improved thermocline storage unit
Copeland, Robert J.
1985-01-01
A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer therebetween. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.
High temperature thermal energy storage in steel and sand
NASA Technical Reports Server (NTRS)
Turner, R. H.
1979-01-01
The technical and economic potential for high temperature (343 C, 650 F) thermal energy storage in hollow steel ingots, pipes embedded in concrete, and for pipes buried in sand was evaluated. Because it was determined that concrete would separate from pipes due to thermal stresses, concrete was replaced by sand, which is free from thermal stresses. Variations of the steel ingot concept were not cost effective compared to the sand-pipe approach, therefore, the sand-pipe thermal storage unit (TSU) was evaluated in depth to assess the approximate tube spacing requirements consistent with different system performance characteristics and also attendant system costs. For large TSUs which do not require fast response times, the sand-pipe approach offers attractive possibilities. A pipe diameter about 9 cm (3.5 in) and pipe spacing of approximately 25 cm (10 in), with sand filling the interspaces, appears appropriate. Such a TSU system designed for 8 hours charge/discharge cycle has an energy unit storage cost (CE) of $2.63/kWhr-t and a power unit storage cost (Cp) of $42/kW-t (in 1977 dollars).
NASA Astrophysics Data System (ADS)
Putnam, S. M.; Harman, C. J.
2017-12-01
Many studies have sought to unravel the influence of landscape structure and catchment state on the quantity and composition of water at the catchment outlet. These studies run into issues of equifinality where multiple conceptualizations of flow pathways or storage states cannot be discriminated against on the basis of the quantity and composition of water alone. Here we aim to parse out the influence of landscape structure, flow pathways, and storage on both the observed catchment hydrograph and chemograph, using hydrometric and water isotope data collected from multiple locations within Pond Branch, a 37-hectare Piedmont catchment of the eastern US. This data is used to infer the quantity and age distribution of water stored and released by individual hydrogeomorphic units, and the catchment as a whole, in order to test hypotheses relating landscape structure, flow pathways, and catchment storage to the hydrograph and chemograph. Initial hypotheses relating internal catchment properties or processes to the hydrograph or chemograph are formed at the catchment scale. Data from Pond Branch include spring and catchment discharge measurements, well water levels, and soil moisture, as well as three years of high frequency precipitation and surface water stable water isotope data. The catchment hydrograph is deconstructed using hydrograph separation and the quantity of water associated with each time-scale of response is compared to the quantity of discharge that could be produced from hillslope and riparian hydrogeomorphic units. Storage is estimated for each hydrogeomorphic unit as well as the vadose zone, in order to construct a continuous time series of total storage, broken down by landscape unit. Rank StorAge Selection (rSAS) functions are parameterized for each hydrogeomorphic unit as well as the catchment as a whole, and the relative importance of changing proportions of discharge from each unit as well as storage in controlling the variability in the catchment chemograph is explored. The results suggest that the quantity of quickflow can be accounted for by direct precipitation onto < 5.2% of the catchment area, representing a zero-order swale plus the riparian area. rSAS modeling suggests that quickflow is largely composed of pre-event, stored water, generated through a process such as groundwater ridging.
Relocatable explosives storage magazine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liptak, R.E.; Keenan, W.A.
A relocatable storage magazine apparatus for storing and retrieving explosives and ordnance and for partially containing and attenuating the blast, conflagration and flying debris from an accidental explosion is described comprising: (a) a container having an access hole; (b) a debris trap attached to the container, the debris trap communicating with said container via the access hole, said debris trap having vent holes for venting the pressure of an explosion from said debris trap to the atmosphere; (c) means for covering said access hole; (d) means for suspending explosives and ordnance from the covering means; (e) means for entering themore » storage magazine to store and retrieve explosives and ordnance; (f) means for retaining said covering means in a position above the access hole wherein said explosives and ordnance are accessible from the entering means.« less
Gao, Wu; Xu, Wenjie; Bian, Xuecheng; Chen, Yunmin
2017-11-01
The settlement of any position of the municipal solid waste (MSW) body during the landfilling process and after its closure has effects on the integrity of the internal structure and storage capacity of the landfill. This paper proposes a practical approach for calculating the settlement and storage capacity of landfills based on the space and time discretization of the landfilling process. The MSW body in the landfill was divided into independent column units, and the filling process of each column unit was determined by a simplified complete landfilling process. The settlement of a position in the landfill was calculated with the compression of each MSW layer in every column unit. Then, the simultaneous settlement of all the column units was integrated to obtain the settlement of the landfill and storage capacity of all the column units; this allowed to obtain the storage capacity of the landfill based on the layer-wise summation method. When the compression of each MSW layer was calculated, the effects of the fluctuation of the main leachate level and variation in the unit weight of the MSW on the overburdened effective stress were taken into consideration by introducing the main leachate level's proportion and the unit weight and buried depth curve. This approach is especially significant for MSW with a high kitchen waste content and landfills in developing countries. The stress-biodegradation compression model was used to calculate the compression of each MSW layer. A software program, Settlement and Storage Capacity Calculation System for Landfills, was developed by integrating the space and time discretization of the landfilling process and the settlement and storage capacity algorithms. The landfilling process of the phase IV of Shanghai Laogang Landfill was simulated using this software. The maximum geometric volume of the landfill error between the calculated and measured values is only 2.02%, and the accumulated filling weight error between the calculated value and measured value is less than 5%. These results show that this approach is practical for satisfactorily and reliably calculating the settlement and storage capacity. In addition, the development of the elevation lines in the landfill sections created with the software demonstrates that the optimization of the design of the structures should be based on the settlement of the landfill. Since this practical approach can reasonably calculate the storage capacity of landfills and efficiently provide the development of the settlement of each landfilling stage, it can be used for the optimizations of landfilling schemes and structural designs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reticulocyte count in red-blood-cell units stored in AS-1.
Urbina, A; Palomino, F
2013-05-01
Previous data that showed maintenance of reticulocyte percentage in whole blood stored in CPDA-1 have led to the assumption that reticulocyte maturation becomes arrested during refrigerated storage. However, reticulocyte behaviour in red-blood-cell units stored in additive solutions has not yet been studied. This study was thus aimed at determining reticulocyte count and reticulocyte subtypes in red-blood-cells units stored in AS-1. Reticulocyte percentage and subtypes were determined by flow cytometry with thiazole orange in six red-blood-cells units stored in AS-1. Reticulocyte count was 26.8 ± 4.6 × 10(9) /l at week 0.5 and 8.2 ± 2.9 × 10(9) /l at week 6. Total haemolysis during storage was 0.19 ± 0.08%. High-fluorescence reticulocytes were 2.0 ± 3.2 × 10(9) /l at week 0.5 and decreased by weeks 2, 4 and 6. Low-fluorescence reticulocytes were 22.1 ± 3.1 × 10(9) /l at week 0.5 and decreased by weeks 4 and 6. A significant decrease in reticulocytes occurred during red-blood-cells units' storage in AS-1. Even if it were assumed that all of haemolysed cells during storage were reticulocytes, there are a number of them whose disappearance cannot be explained by this mechanism. Changes observed in reticulocyte subtypes suggest that they mature during storage. © 2013 The Author(s) Vox Sanguinis © 2013 International Society of Blood Transfusion.
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric substations and liquid storage...
30 CFR 56.4130 - Electric substations and liquid storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric substations and liquid storage...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 5 Administrative Personnel 3 2014-01-01 2014-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
7 CFR 58.241 - Packaging, repackaging and storage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Packaging, repackaging and storage. 58.241 Section 58... Service 1 Operations and Operating Procedures § 58.241 Packaging, repackaging and storage. (a) Containers... palleting or dry storage areas. (c) Repackaging. The entire repackaging operation shall be conducted in a...
10 CFR 34.35 - Labeling, storage, and transportation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Labeling, storage, and transportation. 34.35 Section 34.35... REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.35 Labeling, storage, and transportation. (a... changer or the storage container has securely attached to it a durable, legible, and clearly visible label...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
10 CFR 34.35 - Labeling, storage, and transportation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Labeling, storage, and transportation. 34.35 Section 34.35... REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.35 Labeling, storage, and transportation. (a... changer or the storage container has securely attached to it a durable, legible, and clearly visible label...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
7 CFR 58.241 - Packaging, repackaging and storage.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Packaging, repackaging and storage. 58.241 Section 58... Service 1 Operations and Operating Procedures § 58.241 Packaging, repackaging and storage. (a) Containers... palleting or dry storage areas. (c) Repackaging. The entire repackaging operation shall be conducted in a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 5 Administrative Personnel 3 2013-01-01 2013-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 5 Administrative Personnel 3 2012-01-01 2012-01-01 false Storage. 1312.25 Section 1312.25... Information § 1312.25 Storage. All classified material in the possession of OMB will be stored in a GSA-approved container or in vault-type rooms approved for Top Secret storage. Under the direction of the EOP...
Hmel, Peter J; Kennedy, Anthony; Quiles, John G; Gorogias, Martha; Seelbaugh, Joseph P; Morrissette, Craig R; Van Ness, Kenneth; Reid, T J
2002-07-01
Frozen blood components are shipped on dry ice. The lower temperature (-70 degrees C in contrast to usual storage at -30 degrees C) and shipping conditions may cause a rent in the storage bag, breaking sterility and rendering the unit useless. The rate of loss can reach 50 to 80 percent. To identify those bags with lower probability of breaking during shipment, the thermal and physical properties of blood storage bags were examined. Blood storage bags were obtained from several manufacturers and were of the following compositions: PVC with citrate, di-2-ethylhexylphthalate (DEHP), or tri-2-ethylhexyl-tri-mellitate (TEHTM) plasticizer; polyolefin (PO); poly(ethylene-co-vinyl acetate) (EVA); or fluorinated polyethylene propylene (FEP). The glass transition temperature (Tg) of each storage bag was determined. Bag thickness and measures of material strength (tensile modulus [MT] and time to achieve 0.5 percent strain [T0.5%]) were evaluated. M(T) and T0.5% measurements were made at 25 and -70 degrees C. Response to applied force at -70 degrees C was measured using an impact testing device and a drop test. The Tg of the bags fell into two groups: 70 to 105 degrees C (PO, FEP) and -50 to -17 degrees C (PVC with plasticizer, EVA). Bag thickness ranged from 0.14 to 0.41 mm. Compared to other materials, the ratios of M(T) and T0.5% for PVC bags were increased (p < or = 0.001) indicating that structural changes for PVC were more pronounced upon cooling from 25 to -70 degrees C. Bags containing EVA were more shock resistant, resulting in the lowest rate of breakage (10% breakage) when compared with PO (60% breakage, p = 0.0573) or PVC (100% breakage, p = 0.0001). Blood storage bags made of EVA appear better suited for shipping frozen blood components on dry ice and are cost-effective replacements for PVC bags. For the identification of blood storage bags meeting specific storage requirements, physical and thermal analyses of blood storage bags may be useful and remove empiricism from the process.
Code of Federal Regulations, 2013 CFR
2013-01-01
... devices, transport and storage containers, associated equipment, source changers, and survey instruments... changers, and survey instruments. (a) The licensee shall perform visual and operability checks on survey... condition, that the sources are adequately shielded, and that required labeling is present. Survey...
Code of Federal Regulations, 2011 CFR
2011-01-01
... devices, transport and storage containers, associated equipment, source changers, and survey instruments... changers, and survey instruments. (a) The licensee shall perform visual and operability checks on survey... condition, that the sources are adequately shielded, and that required labeling is present. Survey...
Code of Federal Regulations, 2014 CFR
2014-01-01
... devices, transport and storage containers, associated equipment, source changers, and survey instruments... changers, and survey instruments. (a) The licensee shall perform visual and operability checks on survey... condition, that the sources are adequately shielded, and that required labeling is present. Survey...
Code of Federal Regulations, 2012 CFR
2012-01-01
... devices, transport and storage containers, associated equipment, source changers, and survey instruments... changers, and survey instruments. (a) The licensee shall perform visual and operability checks on survey... condition, that the sources are adequately shielded, and that required labeling is present. Survey...
Code of Federal Regulations, 2010 CFR
2010-01-01
... devices, transport and storage containers, associated equipment, source changers, and survey instruments... changers, and survey instruments. (a) The licensee shall perform visual and operability checks on survey... condition, that the sources are adequately shielded, and that required labeling is present. Survey...
21 CFR 600.11 - Physical establishment, equipment, animals, and care.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of 170 °C maintained for 2 hours with dry heat. Processing and storage containers, filters, filling... “Caution: microbial spores. See directions for storage, use and disposition.”, and (v) the container of... or product dedicated items from the manufacturing area. Environmental monitoring specific for the...
10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...
10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...
10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...
10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...
10 CFR 34.23 - Locking of radiographic exposure devices, storage containers and source changers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Locking of radiographic exposure devices, storage containers and source changers. 34.23 Section 34.23 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment...
21 CFR 864.3250 - Specimen transport and storage container.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Specimen transport and storage container. 864.3250 Section 864.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...
21 CFR 864.3250 - Specimen transport and storage container.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Specimen transport and storage container. 864.3250 Section 864.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...
21 CFR 864.3250 - Specimen transport and storage container.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Specimen transport and storage container. 864.3250 Section 864.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osmanlioglu, Ahmet Erdal
Available in abstract form only. Full text of publication follows: Naturally occurring radioactive material (NORM) in concentrated forms arises both in industry and in nature where natural radioisotopes accumulate at particular sites. Technically enhanced naturally occurring radioactive materials (TE-NORM) often occurs in an acidic environment where precipitates containing radionuclides plate out onto pipe walls, filters, tank linings, etc. Because of the radionuclides are selectively deposited at these sites, radioactivity concentration is extremely higher than the natural concentration. This paper presents characterization and related considerations of TE-NORM wastes in Turkey. Generally, accumulation conditions tend to favour the build-up of radium. Asmore » radium is highly radio-toxic, handling, treatment, storage and disposal of such material requires careful management. Turkey has the only low level waste processing and storage facility (WPSF) in Istanbul. This facility has interim storage buildings and storage area for storage of packaged radioactive waste which are containing artificial radioisotopes, but there is an increasing demand for the storage to accept bulk concentrated TE-NORM wastes from iron-steel and related industries. Most of these wastes generated from scrap metal piles which are imported from other countries. These wastes generally contain radium. (authors)« less
Large-scale thermal storage systems. Possibilities of operation and state of the art
NASA Astrophysics Data System (ADS)
Jank, R.
1983-05-01
The state of the art of large scale thermal energy storage concepts is reviewed. With earth pit storage, the materials question has to be concentrated on. The use of container storage in conventional long distance thermal nets has to be stimulated. Aquifer storage should be tested in a pilot plant to obtain experience in natural aquifer use.
Soil Organic Carbon Storage in Five Different Arctic Permafrost Environments
NASA Astrophysics Data System (ADS)
Fuchs, M.; Grosse, G.; Jones, B. M.; Maximov, G.; Strauss, J.
2016-12-01
Arctic river deltas and ice-rich permafrost regions are highly dynamic environments which will be strongly affected by future climate change. Rapid thaw of permafrost (thermokarst and thermo-erosion) may cause significant mobilization of organic carbon, which is assumed to be stored in large amounts in Arctic river deltas and ice-rich permafrost. This study presents and compares new data on organic carbon storage in thermokarst landforms and Arctic river delta deposits for the first two meters of soils for five different study areas in Alaska and Siberia. The sites include the Ikpikpuk river delta (North Alaska), Fish Creek river delta (North Alaska), Teshekpuk Lake Special Area (North Alaska), Sobo-Sise Island (Lena river delta, Northeast Siberia), and Bykovsky Peninsula (Northeast Siberia). Samples were taken with a SIPRE auger along transects covering the main geomorphological landscape units in the study regions. Our results show a high variability in soil organic carbon storage among the different study sites. The studied profiles in the Teshekpuk Lake Special Area - dominated by drained thermokarst lake basins - contained significantly more carbon than the other areas. The Teshekpuk Lake Special Area contains 44 ± 9 kg C m-2 (0-100 cm, mean value of profiles ± Std dev) compared to 20 ± 7 kg C m-2 kg for Sobo-Sise Island - a Yedoma dominated island intersected by thaw lake basins and 24 ± 6 kg C m-2 for the deltaic dominated areas (Fish Creek and Ikpikpuk). However, especially for the Ikpikpuk river delta, a significant amount of carbon (25 ± 9 kg C m-2) is stored in the second meter of soil (100-200cm). This study shows the importance of including deltaic and thermokarst-affected landscapes as considerable carbon pools, but indicates that these areas are heterogeneous in terms of organic carbon storage and cannot be generalized. As a next step, the site-level carbon stocks will be upscaled to the landscape level using remote sensing-based land cover classifications to calculate the carbon storage potential for Arctic deltas and larger thermokarst regions, to estimate mobilization potentials from thermokarst and thermo-erosion, and to provide input data for future permafrost carbon feedback models.
1986-02-01
precooked frozen packed foods; (2) shelf life of Tray Pack vs. the no. 10 can at ambient and stressful storage temperatures; (3) changes in nutrient...bacteriological tests to certify safety for human consumption. Both Natick RD&E Center and Kraft products were subjected to 9 I...heat processed products that were storage temperature stressed at 380 C, QS data indicated that expected storage life of seven of the CC products was
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mammoli, Andrea A.; Lavrova, Olga; Arellano, Brian
The present invention is an apparatus and method for delivering energy using a renewable resource. The method includes providing a photovoltaic energy source and applying energy storage to the photovoltaic energy source via a battery storage unit. The energy output from the photovoltaic energy source and the battery system is controlled using a battery control system. The battery control system predicts peak load, develops a schedule that includes when to begin discharging power and when to stop discharging power, shifts power to the battery storage unit when excess power is available, and prioritizes the functionality of the battery storage unitmore » and the photovoltaic energy source.« less
Rumondor, Alfred C F; Stanford, Lindsay A; Taylor, Lynne S
2009-12-01
The objective of this study was to investigate the effects of polymer type and storage relative humidity (RH) on the crystallization kinetics of felodipine from amorphous solid dispersions. Crystallization of the model drug felodipine from amorphous solid dispersion samples containing poly(vinyl pyrrolidone) (PVP) and hypromellose acetate succinate (HPMCAS) were evaluated. Samples at three different drug-polymer weight ratios (10, 25, and 50 wt. % polymer) were prepared and stored at six different RHs (0%, 32%, 52% or 66%, 75%, 86%, and 93%). Periodically, the fraction of the drug that had crystallized from the samples was quantified using powder X-ray diffractometry (PXRD). Felodipine crystallization rates from PVP-containing dispersions were found to be very sensitive to changes in storage RH, while crystallization rates from HPMCAS-containing dispersions were not. PVP and HPMCAS were similar in terms of their ability to inhibit crystallization at low RH, but when the storage RH was increased to 75% or above, felodipine crystallization from PVP-containing solid dispersions proceeded much faster. It is hypothesized that this trend was caused by moisture-induced drug-polymer immiscibility in PVP-felodipine system. For PVP-containing solid dispersion samples stored at 75% RH and above, crystallization of the model drug felodipine seemed to approach a kinetic plateau, whereby a fraction of the drug still remained amorphous even after storage for 500 days or more. The physical stability of solid dispersions as a function of RH is highly dependent on the polymer used to form the solid dispersion, with PVP-containing dispersions being much less physically stable at high RH than HPMCAS-containing dispersions.
Saunders, C; Rowe, G; Wilkins, K; Holme, S; Collins, P
2011-08-01
The non-paired two-arm study compared the in vitro storage characteristics of platelets suspended as concentrates in either 100% plasma or a mixture of additive solution (SSP+™, MacoPharma, Mouveaux, France) and autologous plasma in a 70:30 ratio over a 14-day storage period. The buffy coat-derived pooled platelet concentrates were sampled on days 1, 2, 3, 6, 8, 10 and 14 and tests performed to determine platelet morphology, function, metabolism, activation and apoptosis-like activity. Swirling remained strong (score=3) in SSP+™, whilst scores of 1 and 0 were noted for plasma units by end of storage. In contrast to units in plasma, pH levels remained above seven in SSP+™ units, increasing after day 10. Percent positive expression of CD62P was similar in both groups on day 1 (median of 54% and 56% for plasma (n=13) and SSP+™ (n=12), respectively), with SSP+™ units showing a more moderate increase in activation after day 10. A progressive decrease in mitochondrial membrane potential was evident in both groups from day 1, whilst annexin V binding was relatively stable from days 1 to 3, with median values remaining below 6%. Subsequent to this, the percentage of platelets binding annexin V increased to approximately 30% by day 14. Platelets suspended in a medium of 70:30 SSP+™ to plasma ratio performed at least as well as platelets in 100% autologous plasma for up to 10 days of storage. Further, results are suggestive of an apoptosis-like process being involved in the platelet storage lesion. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.
Packaging's Contribution for the Effectiveness of the Space Station's Food Service Operation
NASA Technical Reports Server (NTRS)
Rausch, B. A.
1985-01-01
Storage limitations will have a major effect on space station food service. For example: foods with low bulk density such as ice cream, bread, cake, standard type potato chips and other low density snacks, flaked cereals, etc., will exacerbate the problem of space limitations; package containers are inherently volume consuming and refuse creating; and the useful observation that the optimum package is no package at all leads to the tentative conclusion that the least amount of packaging per unit of food, consistent with storage, aesthetics, preservation, cleanliness, cost and disposal criteria, is the most practical food package for the space station. A series of trade offs may have to be made to arrive at the most appropriate package design for a particular type of food taking all the criteria into account. Some of these trade offs are: single serve vs. bulk; conventional oven vs. microwave oven; nonmetallic aseptically vs. non-aseptically packaged foods; and comparison of aseptic vs. nonaseptic food packages. The advantages and disadvantages are discussed.
Tzounakas, Vassilis L; Kriebardis, Anastasios G; Georgatzakou, Hara T; Foudoulaki-Paparizos, Leontini E; Dzieciatkowska, Monika; Wither, Matthew J; Nemkov, Travis; Hansen, Kirk C; Papassideri, Issidora S; D'Alessandro, Angelo; Antonelou, Marianna H
2016-09-01
This article contains data on the variation in several physiological parameters of red blood cells (RBCs) donated by eligible glucose-6-phosphate dehydrogenase (G6PD) deficient donors during storage in standard blood bank conditions compared to control, G6PD sufficient (G6PD(+)) cells. Intracellular reactive oxygen species (ROS) generation, cell fragility and membrane exovesiculation were measured in RBCs throughout the storage period, with or without stimulation by oxidants, supplementation of N-acetylcysteine and energy depletion, following incubation of stored cells for 24 h at 37 °C. Apart from cell characteristics, the total or uric acid-dependent antioxidant capacity of the supernatant in addition to extracellular potassium concentration was determined in RBC units. Finally, procoagulant activity and protein carbonylation levels were measured in the microparticles population. Further information can be found in "Glucose 6-phosphate dehydrogenase deficient subjects may be better "storers" than donors of red blood cells" [1].
Biological iron-sulfur storage in a thioferrate-protein nanoparticle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaccaro, Brian J.; Clarkson, Sonya M.; Holden, James F.
Iron–sulfur clusters are ubiquitous in biology and function in electron transfer and catalysis. We assembled them from iron and cysteine sulfur on protein scaffolds. Iron is typically stored as iron oxyhydroxide, ferrihydrite, encapsulated in 12 nm shells of ferritin, which buffers cellular iron availability. We have characterized IssA, a protein that stores iron and sulfur as thioferrate, an inorganic anionic polymer previously unknown in biology. IssA forms nanoparticles reaching 300 nm in diameter and is the largest natural metalloprotein complex known. It is a member of a widely distributed protein family that includes nitrogenase maturation factors, NifB and NifX. IssAmore » nanoparticles are visible by electron microscopy as electron-dense bodies in the cytoplasm. Purified nanoparticles appear to be generated from 20 nm units containing B 6,400 Fe atoms and B 170 IssA monomers. In support of roles in both iron–sulfur storage and cluster biosynthesis, IssA reconstitutes the [4Fe-4S] cluster in ferredoxin in vitro.« less
Biological iron-sulfur storage in a thioferrate-protein nanoparticle
Vaccaro, Brian J.; Clarkson, Sonya M.; Holden, James F.; ...
2017-07-20
Iron–sulfur clusters are ubiquitous in biology and function in electron transfer and catalysis. We assembled them from iron and cysteine sulfur on protein scaffolds. Iron is typically stored as iron oxyhydroxide, ferrihydrite, encapsulated in 12 nm shells of ferritin, which buffers cellular iron availability. We have characterized IssA, a protein that stores iron and sulfur as thioferrate, an inorganic anionic polymer previously unknown in biology. IssA forms nanoparticles reaching 300 nm in diameter and is the largest natural metalloprotein complex known. It is a member of a widely distributed protein family that includes nitrogenase maturation factors, NifB and NifX. IssAmore » nanoparticles are visible by electron microscopy as electron-dense bodies in the cytoplasm. Purified nanoparticles appear to be generated from 20 nm units containing B 6,400 Fe atoms and B 170 IssA monomers. In support of roles in both iron–sulfur storage and cluster biosynthesis, IssA reconstitutes the [4Fe-4S] cluster in ferredoxin in vitro.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryan, Charles R.; Schindelholz, Eric John
In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Britemore » TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.« less
Clinical experience with PACS at Northwestern: year two
NASA Astrophysics Data System (ADS)
Channin, David S.; Hawkins, Rodney C.; Enzmann, Dieter R.
2001-08-01
We have previously described the PACS configuration at Northwestern Memorial Hospital (NMH). As opposed to an imaging modality, PACS is an evolving system that continuously grows and changes to meet the needs of the institution. The NMH PACS has grown significantly in the past year and has undergone significant architectural enhancements. This growth and evolutionary change will be described and discussed. The system now contains over 339,000 studies consisting of over 13 million images. There are now two short-term RAID storage units that provide for twice as much fast storage. There are also two magneto-optical disk jukeboxes providing long-term archive. We have deployed a redundant database to improve reliability of the system in the event of database failure. The number of modalities connected to the system has increased and will be summarized. Statistics describing utilization of the PACS will be shown. Lastly, we will discuss our plans for exploiting the application service provider model in our PACS environment.
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
2018-01-03
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Dhumal, Ravindra S; Shimpi, Shamkant L; Paradkar, Anant R
2007-09-01
The purpose of this study was to obtain an amorphous system with minimum unit operations that will prevent recrystallization of amorphous drugs since preparation, during processing (compression) and further storage. Amorphous celecoxib, solid dispersion (SD) of celecoxib with polyvinyl pyrrollidone (PVP) and co-precipitate with PVP and carrageenan (CAR) in different ratios were prepared by the spray drying technique and compressed into tablets. Saturation solubility and dissolution studies were performed to differentiate performance after processing. Differential scanning calorimetry and X-ray powder difraction revealed the amorphous form of celecoxib, whereas infrared spectroscopy revealed hydrogen bonding between celecoxib and PVP. The dissolution profile of the solid dispersion and co-precipitate improved compared to celecoxib and amorphous celecoxib. Amorphous celecoxib was not stable on storage whereas the solid dispersion and co-precipitate powders were stable for 3 months. Tablets of the solid dispersion of celecoxib with PVP and physical mixture with PVP and carrageenan showed better resistance to recrystallization than amorphous celecoxib during compression but recrystallized on storage. However, tablets of co-precipitate with PVP and carageenan showed no evidence of crystallinity during stability studies with comparable dissolution profiles. This extraordinary stability of spray-dried co-precipitate tablets may be attributed to the cushioning action provided by the viscoelastic polymer CAR and hydrogen bonding interaction between celecoxib and PVP. The present study demonstrates the synergistic effect of combining two types of stabilizers, PVP and CAR, on the stability of amorphous drug during compression and storage as compared to their effect when used alone.
Insulation Progress since the Mid-1950s
NASA Astrophysics Data System (ADS)
Timmerhaus, K. D.
Storage vessel and cryostat design for modern cryogenic systems has become rather routine as the result of the wide use of and application of cryogenic fluids. Such vessels for these fluids range in size from 1 L flasks used in the laboratory for liquid nitrogen to the more than 200,000 m3 double-walled tanks used for temporary storage of liquefied natural gas before being transported overseas to their final destination. These storage vessels for cryogenic fluids range in type from low-performance containers insulated with rigid foam or fibrous insulation to high-performance containers insulated with evacuated multilayer insulations. The overriding factors in the type of container selected normally are of economics and safety. This paper will consider various insulation concepts used in such cryogenic storage systems and will review the progress that has been made over the past 50 years in these insulation systems.