Sample records for contamination control procedures

  1. Contamination control plan for prelaunch operations

    NASA Technical Reports Server (NTRS)

    Austin, J. D.

    1983-01-01

    A unified, systematic plan is presented for contamination control for space flight systems. Allowable contaminant quantities, or contamination budgets, are determined based on system performance margins and system-level allowable degradations. These contamination budgets are compared to contamination rates in ground environments to establish the controls required in each ground environment. The use of feedback from contamination monitoring and some contamination control procedures are discussed.

  2. Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

  3. Analysis of Nonvolatile Residue (NVR) from Spacecraft Systems

    NASA Technical Reports Server (NTRS)

    Colony, J. A.

    1985-01-01

    Organic contamination on critical spacecraft surfaces can cause electronic problems, serious attenuation of various optical signals, thermal control changes, and adhesion problems. Such contaminants can be detected early by the controlled use of witness mirrors, witness plates, wipe sampling, or direct solvent extraction. Each method requires careful control of variables of technique and materials to attain the ultimate sensitivities inherent to that procedure. Subsequent chemical analysis of the contaminant sample by infrared and mass spectrometry identifies the components, gives semiquantitative estimates of contaminant thickness, indicates possible sources of the nonvolatile residue (NVR), and provides guidance for effective cleanup procedures.

  4. Contamination control in hybrid microelectronic modules. Identification of critical process and contaminants, part 1

    NASA Technical Reports Server (NTRS)

    Himmel, R. P.

    1975-01-01

    Hybrid processes, handling procedures, and materials were examined to identify the critical process steps in which contamination is most likely to occur, to identify the particular contaminants associated with these critical steps, and to propose method for the control of these contaminants.

  5. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  6. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  7. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  8. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  9. A reliable procedure for decontamination before thawing of human specimens cryostored in liquid nitrogen: three washes with sterile liquid nitrogen (SLN2).

    PubMed

    Parmegiani, Lodovico; Accorsi, Antonio; Bernardi, Silvia; Arnone, Alessandra; Cognigni, Graciela Estela; Filicori, Marco

    2012-10-01

    To report a washing procedure, to be performed as frozen specimens are taken out of cryobanks, to minimize the risk of hypothetical culture contamination during thawing. Basic research. Private assisted reproduction center. Two batches of liquid nitrogen (LN(2)) were experimentally contaminated, one with bacteria (Pseudomonas aeruginosa, Escherichia coli, Stenotrophomonas maltophilia) and the other with fungi (Aspergillus niger). Two hundred thirty-two of the most common human gamete/embryo vitrification carriers (Cryotop, Cryoleaf, Cryopette) were immersed in the contaminated LN(2) (117 in the bacteria and 25 in the fungi-contaminated LN(2)). The carriers were tested microbiologically, one group without washing (control) and the other after three subsequent washings in certified ultraviolet sterile liquid nitrogen (SLN(2)). The carriers were randomly allocated to the "three-wash procedure" (three-wash group, 142 carriers) or "no-wash" (control group, 90 carriers) using a specific software tool. Assessment of microorganism growth. In the no-wash control group, 78.6% of the carriers were contaminated by the bacteria and 100% by the fungi. No carriers were found to be contaminated, either by bacteria or fungi, after the three-wash procedure. The three-wash procedure with SLN(2) produced an efficient decontamination of carriers in extreme experimental conditions. For this reason, this procedure could be routinely performed in IVF laboratories for safe thawing of human specimens that are cryostored in nonhermetical cryocontainers, particularly in the case of open or single-straw closed vitrification systems. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Controlling organic chemical hazards in food manufacturing: a hazard analysis critical control points (HACCP) approach.

    PubMed

    Ropkins, K; Beck, A J

    2002-08-01

    Hazard analysis by critical control points (HACCP) is a systematic approach to the identification, assessment and control of hazards. Effective HACCP requires the consideration of all hazards, i.e., chemical, microbiological and physical. However, to-date most 'in-place' HACCP procedures have tended to focus on the control of microbiological and physical food hazards. In general, the chemical component of HACCP procedures is either ignored or limited to applied chemicals, e.g., food additives and pesticides. In this paper we discuss the application of HACCP to a broader range of chemical hazards, using organic chemical contaminants as examples, and the problems that are likely to arise in the food manufacturing sector. Chemical HACCP procedures are likely to result in many of the advantages previously identified for microbiological HACCP procedures: more effective, efficient and economical than conventional end-point-testing methods. However, the high costs of analytical monitoring of chemical contaminants and a limited understanding of formulation and process optimisation as means of controlling chemical contamination of foods are likely to prevent chemical HACCP becoming as effective as microbiological HACCP.

  11. Indirect latex glove contamination and its inhibitory effect on vinyl polysiloxane polymerization.

    PubMed

    Kimoto, Katsuhiko; Tanaka, Kinya; Toyoda, Minoru; Ochiai, Kent T

    2005-05-01

    The inhibitory effect of indirect latex contamination on the polymerization of vinyl polysiloxane (VPS) impression material has been previously reported. However, the transfer of specific elements that cause inhibition has not been confirmed, nor has the removal of such contaminants been reported. This study examined the surfaces of materials commonly used in restorative procedures that were contaminated by indirect latex glove contact and then evaluated for inhibition of polymerization of VPS. The effect of selected cleansing procedures was then studied. Four experimental groups (n = 8) were prepared: (1) clean vinyl gloves (control), (2) clean gingival retraction cords (control), (3) contaminated vinyl gloves, and (4) contaminated gingival retraction cord. Microscopic evaluation of the appearance and the characterization of surface particulate contamination were performed for each. Three cleansing protocols were then evaluated for efficacy in cleaning vinyl glove surfaces contaminated by latex contact (n = 10): (1) brushing with water, (2) brushing with soap/rinsing with water, (3) cleansing with rubbing alcohol. The subsequent degree of VPS polymerization inhibition was evaluated subjectively. A chi-square test was used for data analysis (alpha=.05). Particulate sulfur elements and sulfur-chloride compounds were present on the contaminated substrates. None of the 3 cleansing procedures eliminated polymerization inhibition (P =.33). Residual elemental sulfur remained on all tested surfaces. Particulate sulfur and sulfur-chloride compounds were identified as the particulate contamination that resulted in polymerization inhibition of the tested VPS dental impression material. Removal of these contaminants from the tested vinyl gloves and gingival retraction cord was not possible with the 3 cleansing protocols tested in this study.

  12. Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system.

    PubMed

    Ülker, E; Bilgin, S; Kahvecioğlu, F; Erkan, A I

    2017-09-01

    To evaluate the effect of different saliva decontamination procedures on the shear bond strength of a one-step universal adhesive system (Single Bond™ Universal Adhesive, 3M ESPE, St. Paul, MN, USA). The occlusal surfaces of 75 human third molars were ground to expose dentin. The teeth were divided into the following groups: Group 1 (control group): Single Bond™ Universal Adhesive was applied to the prepared tooth according to the manufacturer's recommendations and light cured; no contamination procedure was performed. Group 2: Bonding, light curing, saliva contamination, and dry. Group 3: Bonding, light curing, saliva contamination, rinse, and dry. Group 4: After the procedure performed in Group 2, reapplication of bonding. Group 5: After the procedure performed in Group 3, reapplication of bonding. Then, composite resins were applied with cylindrical-shaped plastic matrixes and light cured. For shear bond testing, a notch-shaped force transducer apparatus was applied to each specimen at the interface between the tooth and composite until failure occurred. The data were statistically analyzed using one-way ANOVA. One-way ANOVA revealed significant differences in shear bond strength between the control group and experimental Groups 2 and 4 (P < 0.05). No significant difference was found for experimental Groups 3 and 5 when compared to the control group (P > 0.05). The present in vitro study showed that water rinsing is necessary if cured adhesive resin is contaminated with saliva to ensure adequate bond strength.

  13. Contamination Control in Hybrid Microelectronic Modules. Part 1: Identification of Critical Process and Contaminants

    NASA Technical Reports Server (NTRS)

    Himmel, R. P.

    1975-01-01

    Various hybrid processing steps, handling procedures, and materials are examined in an attempt to identify sources of contamination and to propose methods for the control of these contaminants. It is found that package sealing, assembly, and rework are especially susceptible to contamination. Moisture and loose particles are identified as the worst contaminants. The points at which contaminants are most likely to enter the hybrid package are also identified, and both general and specific methods for their detection and control are developed. In general, the most effective controls for contaminants are: clean working areas, visual inspection at each step of the process, and effective cleaning at critical process steps. Specific methods suggested include the detection of loose particles by a precap visual inspection, by preseal and post-seal electrical testing, and by a particle impact noise test. Moisture is best controlled by sealing all packages in a clean, dry, inert atmosphere after a thorough bake-out of all parts.

  14. Survey of Infection Control Policies within Dental/Educational Patient Treatment Centers.

    ERIC Educational Resources Information Center

    Dickey, Keith Winfield

    1986-01-01

    The article describes a survey of 36 dental education programs to identify educators' reactive policies and procedures in their patient treatment centers to minimize dental contamination and cross-contamination. (Author/CT)

  15. Terrestrial contamination in Apollo lunar samples.

    NASA Technical Reports Server (NTRS)

    Flory, D. A.; Simoneit, B. R.

    1972-01-01

    The contamination prevention procedures adopted for controlling the collection, processing, and analysis of the Apollo lunar samples in order to keep them free of significant levels of terrestrial organic matter are described. The organic contaminants actually found in the samples by the various investigators are summarized. It is shown that the program succeeded in providing investigators with samples containing less than 0.1 ppm total contamination.

  16. Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

    NASA Technical Reports Server (NTRS)

    Fay, M.

    1998-01-01

    This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

  17. Contamination-Free Manufacturing: Tool Component Qualification, Verification and Correlation with Wafers

    NASA Astrophysics Data System (ADS)

    Tan, Samantha H.; Chen, Ning; Liu, Shi; Wang, Kefei

    2003-09-01

    As part of the semiconductor industry "contamination-free manufacturing" effort, significant emphasis has been placed on reducing potential sources of contamination from process equipment and process equipment components. Process tools contain process chambers and components that are exposed to the process environment or process chemistry and in some cases are in direct contact with production wafers. Any contamination from these sources must be controlled or eliminated in order to maintain high process yields, device performance, and device reliability. This paper discusses new nondestructive analytical methods for quantitative measurement of the cleanliness of metal, quartz, polysilicon and ceramic components that are used in process equipment tools. The goal of these new procedures is to measure the effectiveness of cleaning procedures and to verify whether a tool component part is sufficiently clean for installation and subsequent routine use in the manufacturing line. These procedures provide a reliable "qualification method" for tool component certification and also provide a routine quality control method for reliable operation of cleaning facilities. Cost advantages to wafer manufacturing include higher yields due to improved process cleanliness and elimination of yield loss and downtime resulting from the installation of "bad" components in process tools. We also discuss a representative example of wafer contamination having been linked to a specific process tool component.

  18. Importance of good manufacturing practices in microbiological monitoring in processing human tissues for transplant.

    PubMed

    Pianigiani, Elisa; Ierardi, Francesca; Fimiani, Michele

    2013-12-01

    Skin allografts represent an important therapeutic resource in the treatment of severe skin loss. The risk associated with application of processed tissues in humans is very low, however, human material always carries the risk of disease transmission. To minimise the risk of contamination of grafts, processing is carried out in clean rooms where air quality is monitored. Procedures and quality control tests are performed to standardise the production process and to guarantee the final product for human use. Since we only validate and distribute aseptic tissues, we conducted a study to determine what type of quality controls for skin processing are the most suitable for detecting processing errors and intercurrent contamination, and for faithfully mapping the process without unduly increasing production costs. Two different methods for quality control were statistically compared using the Fisher exact test. On the basis of the current study we selected our quality control procedure based on pre- and post-processing tissue controls, operator and environmental controls. Evaluation of the predictability of our control methods showed that tissue control was the most reliable method of revealing microbial contamination of grafts. We obtained 100 % sensitivity by doubling tissue controls, while maintaining high specificity (77 %).

  19. Transmission and control of Salmonella in the pig feed chain: a conceptual model.

    PubMed

    Binter, Claudia; Straver, Judith Maria; Häggblom, Per; Bruggeman, Geert; Lindqvist, Per-Anders; Zentek, Jürgen; Andersson, Mats Gunnar

    2011-03-01

    Infected breeder pigs and contaminated feed represent potential sources of Salmonella introduction to fattening pig herds and may thereby cause human infections acquired via consumption of contaminated pork. Modelling approaches such as quantitative microbial risk assessment could improve the design of strategies for control and tracing of Salmonella in the feed chain. However, the construction of such models requires a thorough understanding of the dynamics of the feed chain, including production processes, microbial processes and transport logistics. The present article illustrates a conceptual model of Salmonella in the pig feed chain and explores the possibilities for quantitative modelling including identifying major gaps in data. Information was collected from peer-reviewed scientific journals, official documents and reports and by means of interviews with experts from authorities and the feed industry. Data on prevalence of Salmonella in different parts of the feed chain are difficult to compare as observed prevalence may be biased by variations in sampling procedures as well as limitations of the detection methods. There are almost no data on numbers of Salmonella in commodities of the feed chain, which often makes it difficult to evaluate risks, intervention strategies and sampling plans in a quantitative manner. Tracing the source of Salmonella contamination is hampered by the risk of cross-contamination as well as various mixing and partitioning events along the supply chain, which sometimes makes it impossible to trace the origin of a lot back to a batch or producer. Available information points to contaminated feed materials, animal vectors and persistent contamination of production environments as important sources of Salmonella in feed production. Technological procedures such as hydrothermal or acid treatment can be used to control Salmonella in feed production. However, a large fraction of pig feed is produced without decontamination procedures. Prevention of recontamination and control of moisture throughout the chain are thus critical factors for controlling Salmonella in feed production. To verify successful control it is necessary to have monitoring strategies able to detect low levels of Salmonella heterogeneously distributed in large volumes of feed and feed material in bulk. Experience from monitoring programs and research investigations indicates that sampling of dust and sweepings from control points along the production line is an efficient strategy to gain an indication of Salmonella contamination. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Molecular Identification of Fungal Contamination in Date Palm Tissue Cultures.

    PubMed

    Abass, Mohammed H

    2017-01-01

    Fungal contamination of in vitro cultures of date palm (Phoenix dactylifera L.) is the major constraint to their initiation and maintenance. Different molecular approaches have been applied successfully to analyze both inter- and intraspecific variation among fungal species as well as determine their identity. This chapter describes step-by-step procedures of molecular identification of fungal contaminants by internal transcribed spacer (ITS) products of the most common fungal contaminants of date palm tissue culture. To begin with, samples of genera Alternaria, Aspergillus, Cladosporium, Epicoccum, and Penicillium were collected to isolate each fungal genus and extraction of genomic DNA. Polymerase chain reactions were accomplished by ITS primers (ITS1 and ITS4) for each fungal contaminant as well as for sequencing. Subsequently, they are analyzed by Basic Local Alignment Search Tool (BLAST) search of ITS sequence to reveal the identity of each individual fungal contaminant species. The molecular identification herein is a rapid and reliable procedure to identify date palm fungal contaminants which is very important in their control and treatment.

  1. Assessing Metal Mobilization from Industrially Lead-Contaminated Soils Located at an Urban Site

    EPA Science Inventory

    A series of leaching and partitioning tests (Toxicity Characteristic Leaching Procedure (TCLP), Synthetic Precipitation Leaching Procedure (SPLP), Controlled Acidity Leaching Protocol (CALP), Acid Neutralization Capacity (ANC), and sequential extraction) were applied to three dif...

  2. Space Stirling Cryocooler Contamination Lessons Learned and Recommended Control Procedures

    NASA Astrophysics Data System (ADS)

    Glaister, D. S.; Price, K.; Gully, W.; Castles, S.; Reilly, J.

    The most important characteristic of a space cryocooler is its reliability over a lifetime typically in excess of 7 years. While design improvements have reduced the probability of mechanical failure, the risk of internal contamination is still significant and has not been addressed in a consistent approach across the industry. A significant fraction of the endurance test and flight units have experienced some performance degradation related to internal contamination. The purpose of this paper is to describe and assess the contamination issues inside long life, space cryocoolers and to recommend procedures to minimize the probability of encountering contamination related failures and degradation. The paper covers the sources of contamination, the degradation and failure mechanisms, the theoretical and observed cryocooler sensitivity, and the recommended prevention procedures and their impact. We begin with a discussion of the contamination sources, both artificial and intrinsic. Next, the degradation and failure mechanisms are discussed in an attempt to arrive at a contaminant susceptibility, from which we can derive a contamination budget for the machine. This theoretical sensitivity is then compared with the observed sensitivity to illustrate the conservative nature of the assumed scenarios. A number of lessons learned on Raytheon, Ball, Air Force Research Laboratory, and NASA GSFC programs are shared to convey the practical aspects of the contamination problem. Then, the materials and processes required to meet the proposed budget are outlined. An attempt is made to present a survey of processes across industry.

  3. Bibliography: Codes, standards, procedures, specifications and reports relating to contamination control

    NASA Technical Reports Server (NTRS)

    Ledoux, F. N.

    1970-01-01

    The bibliography is arranged in separate sections under headings that include: (1) spacecraft cleanliness, (2) general cleaning, (3) clean room and work stations, (4) contamination, (5) decontamination, (6) manufacturing, (7) miscellaneous, (8) particle count analysis, (9) passivation, (10) packaging, (11) water, and (12) acids and detergents.

  4. Comparison of hand hygiene procedures for removing Bacillus cereus spores.

    PubMed

    Sasahara, Teppei; Hayashi, Shunji; Hosoda, Kouichi; Morisawa, Yuji; Hirai, Yoshikazu

    2014-01-01

    Bacillus cereus is a spore-forming bacterium. B. cereus occasionally causes nosocomial infections, in which hand contamination with the spores plays an important role. Therefore, hand hygiene is the most important practice for controlling nosocomial B. cereus infections. This study aimed to determine the appropriate hand hygiene procedure for removing B. cereus spores. Thirty volunteers' hands were experimentally contaminated with B. cereus spores, after which they performed 6 different hand hygiene procedures. We compared the efficacy of the procedures in removing the spores from hands. The alcohol-based hand-rubbing procedures scarcely removed them. The soap washing procedures reduced the number of spores by more than 2 log10. Extending the washing time increased the spore-removing efficacy of the washing procedures. There was no significant difference in efficacy between the use of plain soap and antiseptic soap. Handwashing with soap is appropriate for removing B. cereus spores from hands. Alcohol-based hand-rubbing is not effective.

  5. The influence of salivary contamination on shear bond strength of dentin adhesive systems.

    PubMed

    Park, Jeong-won; Lee, Kyung Chae

    2004-01-01

    This study evaluated the influence of salivary contamination during dentin bonding procedures on shear bond strength and investigated the effect of contaminant-removing treatments on the recovery of bond strength for two dentin bonding agents. One hundred and ten human molars were embedded in cylindrical molds with self-curing acrylic resin. The occlusal dentin surface was exposed by wet grinding with #800 silicon carbide abrasive paper. The teeth were divided into five groups for One-step (OS) (BISCO, Inc) and six groups for Clearfil SE Bond (SE) (Kuraray Co, Ltd, Osaka, Japan). For One-step, the grinding surface was treated with 32% phosphoric acid; BAC (BISCO Inc) and divided into five groups: OS control group (uncontaminated), OS I (salivary contamination, blot dried), OS II (salivary contamination, completely dried), OS III (salivary contamination, wash and blot dried) and OS IV (salivary contamination, re-etching for 10 seconds, wash and blot dried). For SE bond, the following surface treatments were done: SE control group (primer applied to the fresh dentin surface), SE I (after salivary contamination, primer applied), SE II (primer, salivary contamination, dried), SE III (primer, salivary contamination, wash and dried), SE IV (after procedure of SE II, re-application of primer) and SE V (after procedure of SE III, re-application of primer). Each bonding agent was applied and light cured for 10 seconds. Clearfil AP-X (Kuraray Co, Ltd) composite was packed into the Ultradent mount jig mold and light cured for 40 seconds. The bonded specimens were stored for 24 hours in a 37 degrees C waterbath. The shear bond strengths were measured using an Instron testing machine (Model 4202, Instron Corp). The data for each group were subjected to one-way ANOVA followed by the Newman-Keuls test to make comparisons among the groups. The results were as follows: In the One-step groups, the OS II group showed statistically significant lower shear bond strength than the OS control, I, III and IV (p<0.05). In the Clearfil SE Bond groups, the SE II and SE III groups had decreased shear bond strength compared with the control and SE I, SE IV and SE V groups (p<0.05). In conclusion, when using One-step total etch adhesive and when the etched surface is contaminated by saliva, blotting the surface and applying the primer can recover the bond strength. Complete drying of the salivary contaminated surface should be avoided. In the Clearfil SE Bond groups, the re-priming treatment (SE IV and SE V) resulted in the recovery of shear bond strength in the specimens contaminated after priming.

  6. Health care facility-based decontamination of victims exposed to chemical, biological, and radiological materials.

    PubMed

    Koenig, Kristi L; Boatright, Connie J; Hancock, John A; Denny, Frank J; Teeter, David S; Kahn, Christopher A; Schultz, Carl H

    2008-01-01

    Since the US terrorist attacks of September 11, 2001, concern regarding use of chemical, biological, or radiological weapons is heightened. Many victims of such an attack would present directly to health care facilities without first undergoing field decontamination. This article reviews basic tenets and recommendations for health care facility-based decontamination, including regulatory concerns, types of contaminants, comprehensive decontamination procedures (including crowd control, triage, removal of contaminated garments, cleaning of body contaminants, and management of contaminated materials and equipment), and a discussion of methods to achieve preparedness.

  7. Influence of orthopedic reinforced gloves versus double standard gloves on contamination events during small animal orthopedic surgery.

    PubMed

    Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie

    2017-10-01

    To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P < .001) with each additional minute of surgery. Orthopedic reinforced gloves and double standard gloving were equally effective at preventing contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.

  8. EFFECT OF PRE-EVISCERATION, SKIN-ON CARCASS DECONTAMINATION SANITATION STRATEGIES FOR REDUCING BACTERIAL CONTAMINATION OF BEEF DURING SKINNING

    USDA-ARS?s Scientific Manuscript database

    The effectiveness of pre-evisceration, skin-on carcass sanitation on reducing bacterial contamination of beef carcasses was tested using 3 cattle per treatment and 3 cattle as controls at each of 3 abattoirs in southern Wisconsin. The sanitation procedure included stunning, bleeding, tying off the e...

  9. Environmental Assessment of Proposed Mixed-Use Business Park on an Enchanced Use Lease at Grand Forks Air Force Base, North Dakota

    DTIC Science & Technology

    2014-04-01

    remediate past environmental contamination on Air Force installations. Past procedures for managing and disposing wastes, although accepted at the...time, resulted in contamination of the environment. The ERP has established a process to evaluate past disposal sites, control the migration of... contaminants , identify potential hazards to human health and the environment, and remediate the sites. 3.5.2 Existing Conditions GFAFB is a

  10. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures

    PubMed Central

    Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M.; Proietto, Anna R.; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-01-01

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. PMID:26969696

  11. 9 CFR 381.309 - Finished product inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... FSIS-approved total quality control system; or (3) Alternative documented procedures that will ensure... contamination, where there is no approved total quality control system, or where the establishment has no... Office of Management and Budget under control number 0583-0015) [51 FR 45634, Dec. 19, 1986, as amended...

  12. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations

    PubMed Central

    Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-01-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274

  13. Evaluation of standardized sample collection, packaging, and decontamination procedures to assess cross-contamination potential during Bacillus anthracis incident response operations.

    PubMed

    Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall

    2016-12-01

    Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.

  14. How-to-Do-It: Infection Control Guidelines for Blood Typing & Blood Smear Labs.

    ERIC Educational Resources Information Center

    Vetter, Edwin A.

    1989-01-01

    Provides a set of guidelines for infection control of the Acquired Immune Deficiency Syndrome and the serum hepatitis viruses during blood typing procedures. Emphasizes that disposal of blood contaminated materials should comply with local health department recommendations. (RT)

  15. Admixture enhanced controlled low-strength material for direct underwater injection with minimal cross-contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hepworth, H.K.; Davidson, J.S.; Hooyman, J.L.

    1997-03-01

    Commercially available admixtures have been developed for placing traditional concrete products under water. This paper evaluates adapting anti-washout admixture (AWA) and high range water reducing admixture (HRWRA) products to enhance controlled low-strength materials (CLSMs) for underwater placement. A simple experimental scale model (based on dynamic and geometric similitude) of typical grout pump emplacement equipment has been developed to determine the percentage of cementing material washed out. The objective of this study was to identify proportions of admixtures and underwater CLSM emplacement procedures which would minimize the cross-contamination of the displaced water while maintaining the advantages of CLSM. Since the displacedmore » water from radioactively contaminated systems must be subsequently treated prior to release to the environment, the amount of cross-contamination is important for cases in which cementing material could form hard sludges in a water treatment facility and contaminate the in-place CLSM stabilization medium.« less

  16. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

    PubMed

    Marchesi, Isabella; Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M; Proietto, Anna R; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-05-15

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  17. STATE WATER RESOURCES RESEARCH INSTITUTE PROGRAM: GROUND WATER RESEARCH.

    USGS Publications Warehouse

    Burton, James S.; ,

    1985-01-01

    This paper updates a review of the accomplishments of the State Water Resources Research Program in ground water contamination research. The aim is to assess the progress made towards understanding the mechanisms of ground water contamination and based on this understanding, to suggest procedures for the prevention and control of ground water contamination. The following research areas are covered: (1) mechanisms of organic contaminant transport in the subsurface environment; (2) bacterial and viral contamination of ground water from landfills and septic tank systems; (3) fate and persistence of pesticides in the subsurface; (4) leachability and transport of ground water pollutants from coal production and utilization; and (5) pollution of ground water from mineral mining activities.

  18. Prevention of water-contamination of ethanol-saturated dentin and hydrophobic hybrid layers

    PubMed Central

    Sauro, Salvatore; Watson, Timothy F; Mannocci, Francesco; Tay, Franklin R; Pashley, David H

    2013-01-01

    SUMMARY Purpose This in vitro study evaluated the amount and the distribution of outward fluid flow that occurred when an experimental etch-and-rinse hydrophobic adhesive was applied to ethanol-saturated dentin before and after oxalate pretreatment. Materials and methods Measurements of dentin permeability were performed under a constant pulpal pressure of 20 cm H2O in deep and middle dentin. A lucifer yellow solution was placed in the pulp chamber to determine the distribution of the water contamination of the hybrid layers. Results The distribution of fluorescence in dentin specimens that were not pretreated with oxalate revealed that the dye permeated around the resin tags and filled the hybrid layer. Dentin specimens pretreated with oxalate prior to resin bonding, showed 80–83% less (p<0.05) water contamination compared to controls. The dentin permeability results obtained before and after oxalate pretreatment showed that oxalate decreased dentin permeability by 98% (p<0.05) compared to acid-etched controls. This prevented outward fluid movement during bonding resulting in better resin sealing of dentin due to the formation of a double seal of resin tags over calcium oxalate crystals in the tubules. Conclusion Outward dentinal fluid flow may contaminate hybrid layers during adhesive bonding procedures. Pretreatment of acid-etched dentin with 3% oxalic acid prior to bonding procedures can prevent outward fluid flow during bonding and water contamination of the hydrophobic hybrid layers. PMID:19701507

  19. Overview of the US EPA/SERDP/ESTCP: Laboratory, Field ...

    EPA Pesticide Factsheets

    Passive sampling can be used for applications at contaminated sediment sites including performing assessments of contaminant bioavailability (i.e., freely dissolved concentration (Cfree)), conducting remedial investigations and feasibility studies, and assessing the potential for contaminant bioaccumulation. Previous research articles and documents have discussed many aspects of passive sampling however no definitive guidance on the laboratory, field and analytical procedures for using passive sampling at contaminated sediment sites has been provided. The document discussed in this presentation provides passive sampler users with the guidance necessary to apply the technology to evaluate contaminated sediments. Contaminants discussed include polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and the metals, cadmium, copper, nickel, lead and zinc. The document is divided into sections including discussions of different types of samplers used commonly in the United States, the selection and use of performance reference compounds (PRCs), the extraction and instrumental analysis of passive samplers, data analysis and quality assurance/quality control, and a list of passive sampling related references. The document is not intended to serve as a series of standard operating procedures (SOPs) but rather seeks to provide users with the information needed to develop their own SOPs. The document also includes the names of selected passive sam

  20. Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device

    PubMed Central

    Cavalieri, R. Jennifer; Marolf, Cole; Lyden, Elizabeth

    2017-01-01

    Abstract Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5–2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. Clinical Trials Registration. NCT02102087. PMID:28379370

  1. Shuttle optical environment; Proceedings of the Meeting, Washington, DC, April 23, 24, 1981

    NASA Technical Reports Server (NTRS)

    Miller, E. R. (Editor); Fazio, G. G.

    1982-01-01

    The numerical modeling, instrumentation, identification, and procedures to characterize and/or control contamination hazards to equipment used on the Shuttle are discussed. On-orbit pollutants include molecular offgassing and outgassing, particulate material, and substances from thrusters, vents, and leaks. Clean-rooms are being implemented in ground assembly and integration facilities. Attention is given to an upgraded SPACE program for numerically modeling contamination pathways and appropriate procedures to protect instrumentation from film and particulate deposition. Finally, attention is given to military cryogenic IR detectors being employed to quantify the Shuttle thermal and solid pollutant environment on-orbit as a prelude to future operational IR sensors.

  2. Evaluation of standardized sample collection, packaging, and ...

    EPA Pesticide Factsheets

    Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.

  3. Assessment of microbial contamination of radiographic equipment and materials during intraoral imaging procedures.

    PubMed

    Pinheiro, S L; Martoni, S C; Ogera, R R

    2012-05-01

    Aim of the present study was to assess microbial contamination of radiology procedures. Patients who needed radiographic exams were selected and the bisecting technique was used: G1 - (control): absence of plastic barrier and overgloving or disinfectant solutions; G2 - alcohol spraying; G3 - protection of the film with a plastic barrier and alcohol spray; G4 - protection of film with plastic barrier, use of overgloving and alcohol spray. The following regions were assessed: trigger switch, X-ray tube, sleeve of the portable dark chamber, water, developer and fixer. The areas for microbiological sample collection were standardized with a label cut internally so that the hollow area was 5 cm long and 2 cm wide. One mL of the developer, water and fixer were also collected before and after developing the films. The samples were incubated under anaerobiosis and aerobiosis. The results were submitted to the Cochran's Q and Mann-Whitney tests. The sleeve of the developing chamber showed greater anaerobic contamination followed by the X-ray tube and only the use of alcohol associated with mechanical barriers was efficient to control this microbiota. The trigger showed higher aerobic microbial contamination and the use of alcohol or alcohol associated with mechanical barriers was efficient to control this microbiota. The developing solutions presented no significant growth of anaerobic and aerobic bacteria. The characteristic of an aerobic or anaerobic microbial strain influences microbial contamination while radiographic projections are being taken and the use of alcohol associated with a plastic barrier and overgloving is indicated to reduce this microbiota.

  4. Hygiene intervention reduces contamination of weaning food in Bangladesh.

    PubMed

    Islam, Mohammad Sirajul; Mahmud, Zahid Hayat; Gope, Partha Sarathi; Zaman, Rokon Uz; Hossain, Zakir; Islam, Mohammad Shafiqul; Mondal, Dinesh; Sharker, Mohammad Abu Yushuf; Islam, Khairul; Jahan, Hasin; Bhuiya, Abbas; Endtz, Hubert P; Cravioto, Alejandro; Curtis, Valerie; Touré, Ousmane; Cairncross, Sandy

    2013-03-01

    This study was conducted to measure the impact of a hygiene intervention on the contamination of weaning food in Bangladesh. Sixty households were selected: 30 study and 30 control households. Samples of weaning food were collected from all the 60 households at baseline and examined for faecal coliforms (FC), faecal streptococci (FS) and Clostridium perfringens (CP) following standard procedures. After cooking, food samples were collected on three occasions before feeding. Following Hazard Analysis Critical Control Point (HACCP) procedures, critical control points were determined. The mothers in the 30 study households were then trained for 4 weeks in how to attain the control point conditions. Then, again the food samples were collected and analysed. At baseline, weaning foods from study and control households were heavily contaminated with FC and FS. The FC and FS counts were 1.84 log(10) and 1.92 log(10) colony-forming unit (cfu)/g, respectively, in the study households, and 0.86 log(10) and 1.33 log(10)  cfu/g, respectively, in the control households in the first feeding. After the intervention, the FC and FS counts in study households had dropped to 0.10 log(10) and 0.09 log(10)  cfu/g, respectively, a statistically significant reduction (P < 0.001). Monitoring the sustainability of the behaviour change after 3 months showed that the mothers were maintaining food hygiene. A hygiene intervention following the HACCP approach reduced the weaning food contamination significantly. Awareness building among mothers about weaning food hygiene could be an important intervention for preventing weaning food-related diarrhoea in Bangladesh. © 2012 Blackwell Publishing Ltd.

  5. Bacterial burden in the operating room: impact of airflow systems.

    PubMed

    Hirsch, Tobias; Hubert, Helmine; Fischer, Sebastian; Lahmer, Armin; Lehnhardt, Marcus; Steinau, Hans-Ulrich; Steinstraesser, Lars; Seipp, Hans-Martin

    2012-09-01

    Wound infections present one of the most prevalent and frequent complications associated with surgical procedures. This study analyzes the impact of currently used ventilation systems in the operating room to reduce bacterial contamination during surgical procedures. Four ventilation systems (window-based ventilation, supported air nozzle canopy, low-turbulence displacement airflow, and low-turbulence displacement airflow with flow stabilizer) were analyzed. Two hundred seventy-seven surgical procedures in 6 operating rooms of 5 different hospitals were analyzed for this study. Window-based ventilation showed the highest intraoperative contamination (13.3 colony-forming units [CFU]/h) followed by supported air nozzle canopy (6.4 CFU/h; P = .001 vs window-based ventilation) and low-turbulence displacement airflow (3.4 and 0.8 CFU/h; P < .001 vs window-based ventilation and supported air nozzle canopy). The highest protection was provided by the low-turbulence displacement airflow with flow stabilizer (0.7 CFU/h), which showed a highly significant difference compared with the best supported air nozzle canopy theatre (3.9 CFU/h; P < .001). Furthermore, this system showed no increase of contamination in prolonged durations of surgical procedures. This study shows that intraoperative contamination can be significantly reduced by the use of adequate ventilation systems. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  6. Salivary contamination during bonding procedures with a one-bottle adhesive system.

    PubMed

    Fritz, U B; Finger, W J; Stean, H

    1998-09-01

    The effect of salivary contamination of enamel and dentin on bonding efficacy of an experimental one-bottle resin adhesive was investigated. The adhesive was a light-curing urethane dimethacrylate/hydroxyethyl methacrylate/4-methacryloxyethyl trimellitate anhydride mixture dissolved in acetone. Evaluation parameters were shear bond strength and marginal gap width in a dental cavity. Apart from a control group without contamination (group 1), etched enamel and dentin were (2) contaminated with saliva and air dried; (3) contaminated, rinsed, and blot dried; (4) coated with adhesive, contaminated, rinsed, and blot dried; (5) coated with adhesive, light cured, contaminated, rinsed, and air dried; or (6) treated as in group 5, with additional adhesive application after air drying. There was no negative effect in groups 3 and 4, compared with control. Air drying after salivary contamination (group 2) resulted in low shear bond strengths and wide marginal gaps. Contamination of the cured adhesive layer (groups 5 and 6) had no adverse effect on enamel shear bond strengths, but resulted in 50% reduced dentin shear bond strengths and wide marginal gaps. The one-bottle adhesive system is relatively insensitive to salivary contamination, provided that the contamination occurs prior to light curing of the adhesive and is carefully rinsed and blot dried. Salivary contact after adhesive curing must be avoided.

  7. Critical control points of complementary food preparation and handling in eastern Nigeria.

    PubMed Central

    Ehiri, J. E.; Azubuike, M. C.; Ubbaonu, C. N.; Anyanwu, E. C.; Ibe, K. M.; Ogbonna, M. O.

    2001-01-01

    OBJECTIVE: To investigate microbial contamination and critical control points (CCPs) in the preparation and handling of complementary foods in 120 households in Imo state, Nigeria. METHODS: The Hazard Analysis Critical Control Point (HACCP) approach was used to investigate processes and procedures that contributed to microbial contamination, growth and survival, and to identify points where controls could be applied to prevent or eliminate these microbiological hazards or reduce them to acceptable levels. Food samples were collected and tested microbiologically at different stages of preparation and handling. FINDINGS: During cooking, all foods attained temperatures capable of destroying vegetative forms of food-borne pathogens. However, the risk of contamination increased by storage of food at ambient temperature, by using insufficiently high temperatures to reheat the food, and by adding contaminated ingredients such as dried ground crayfish and soybean powder at stages where no further heat treatment was applied. The purchasing of contaminated raw foodstuffs and ingredients, particularly raw akamu, from vendors in open markets is also a CCP. CONCLUSION: Although an unsafe environment poses many hazards for children's food, the hygienic quality of prepared food can be assured if basic food safety principles are observed. When many factors contribute to food contamination, identification of CCPs becomes particularly important and can facilitate appropriate targeting of resources and prevention efforts. PMID:11417038

  8. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples

    USGS Publications Warehouse

    Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.

    1996-01-01

    Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.

  9. Management of neurosurgical instruments and patients exposed to Creutzfeldt-Jakob disease.

    PubMed

    Belay, Ermias D; Blase, Jennifer; Sehulster, Lynne M; Maddox, Ryan A; Schonberger, Lawrence B

    2013-12-01

    To summarize the approaches used to manage exposure of patients to inadequately sterilized neurosurgical instruments contaminated as a result of Creutzfeldt-Jakob disease (CJD). Information on past CJD exposure incidents reported to the Centers for Disease Control and Prevention (CDC) was aggregated and summarized. In addition, inactivation studies were reviewed, and data from selected publications were provided for reference. Nineteen incidents of patient exposure to potentially CJD-contaminated instruments were reported to the CDC, including 17 that involved intracranial procedures and 2 that involved ophthalmologic procedures. In more than 50% of incidents, the neurosurgical procedures were performed for diagnostic work up of the index patients. At least 12 of the hospitals had multiple neurosurgical sets, and the CJD-contaminated instruments could not be identified in 11 of 19 hospitals. In 12 of 15 hospitals with neurosurgical incidents, a decision was made to notify patients of their potential exposure. Neurosurgical instruments used for treatment of patients with suspected or diagnosed CJD or patients whose diagnosis is unclear should be promptly identified and sterilized using recommended CJD decontamination protocols. Inability to trace instruments complicates appropriate management of exposure incidents. The feasibility of instituting instrument tracking procedures should be considered.

  10. Management of Neurosurgical Instruments and Patients Exposed to Creutzfeldt-Jakob Disease

    PubMed Central

    Belay, Ermias D.; Blase, Jennifer; Sehulster, Lynne M.; Maddox, Ryan A.; Schonberger, Lawrence B.

    2015-01-01

    OBJECTIVE To summarize the approaches used to manage exposure of patients to inadequately sterilized neurosurgical instruments contaminated as a result of Creutzfeldt-Jakob disease (CJD). METHODS Information on past CJD exposure incidents reported to the Centers for Disease Control and Prevention (CDC) was aggregated and summarized. In addition, inactivation studies were reviewed, and data from selected publications were provided for reference. RESULTS Nineteen incidents of patient exposure to potentially CJD-contaminated instruments were reported to the CDC, including 17 that involved intracranial procedures and 2 that involved ophthalmologic procedures. In more than 50% of incidents, the neurosurgical procedures were performed for diagnostic work up of the index patients. At least 12 of the hospitals had multiple neurosurgical sets, and the CJD-contaminated instruments could not be identified in 11 of 19 hospitals. In 12 of 15 hospitals with neurosurgical incidents, a decision was made to notify patients of their potential exposure. CONCLUSIONS Neurosurgical instruments used for treatment of patients with suspected or diagnosed CJD or patients whose diagnosis is unclear should be promptiy identified and sterilized using recommended CJD decontamination protocols. Inability to trace instruments complicates appropriate management of exposure incidents. The feasibility of instituting instrument tracking procedures should be considered. PMID:24225612

  11. ModBack - simplified contaminant source zone delineation using backtracking

    NASA Astrophysics Data System (ADS)

    Thielsch, K.; Herold, M.; Ptak, T.

    2012-12-01

    Contaminated groundwater poses a serious threat to drinking water resources all over the world. Even though contaminated water might be detected in observation wells, a proper clean up is often only successful if the source of the contamination is detected and subsequently removed, contained or remediated. The high costs of groundwater remediation could be possibly significantly reduced if, from the outset, a focus is placed on source zone detection. ModBack combines several existing modelling tools in one easy to use GIS-based interface helping to delineate potential contaminant source zones in the subsurface. The software is written in Visual Basic 3.5 and uses the ArcObjects library to implement all required GIS applications. It can run without modification on any Microsoft Windows based PC with sufficient RAM and at least Microsoft .NET Framework 3.5. Using ModBack requires additional installation of the following software: Processing Modflow Pro 7.0, ModPath, CSTREAM (Bayer-Raich et al., 2003), Golden Software Surfer and Microsoft Excel. The graphical user interface of ModBack is separated into four blocks of procedures dealing with: data input, groundwater modelling, backtracking and analyses. Geographical data input includes all georeferenced information pertaining to the study site. Information on subsurface contamination is gathered either by conventional sampling of monitoring wells or by conducting integral pumping tests at control planes with a specific sampling scheme. Hydraulic data from these pumping tests together with all other available information are then used to set up a groundwater flow model of the study site, which provides the flow field for transport simulations within the subsequent contamination backtracking procedures, starting from the defined control planes. The backtracking results are then analysed within ModBack. The potential areas of contamination source presence or absence are determined based on the procedure used by Jarsjö et al. (2005). The contaminant plume length can be estimated using plume length statistics, first order rate degradation equations or calculations based on site specific hydraulic and chemical parameters. Furthermore, an analytical tool is included to identify the distribution of contaminants across a control plane. All relevant output can be graphically displayed and saved as vector data to be later used in GIS software. ModBack has been already used to delimit the zones of source presence or absence at several test sites. With ModBack, a tool is now available which enables environmental consultants, engineers and environmental agencies to delineate possible sources of contamination already at the planning stage of site investigation and remediation measures, helping to significantly reduce costs of contaminated site management. Bayer-Raich, M., Jarsjö, J., Holder, T. and Ptak, T. (2003): "Numerical estimations of contaminant mass flow rate based on concentration measurements in pumping wells", ModelCare 2002: A Few Steps Closer to Reality, IAHS Publication No. 277, 10-16. Jarsjö, J., Bayer-Raich, M., Ptak, T. (2005): "Monitoring groundwater contamination and delineating source zones at industrial sites: Uncertainty analyses using integral pumping tests", Journal of Contaminant Hydrology, 79, 107-134

  12. Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

    NASA Technical Reports Server (NTRS)

    Ramirez, W. Fred; Skliar, Mikhail; Narayan, Anand; Morgenthaler, George W.; Smith, Gerald J.

    1998-01-01

    Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996).

  13. Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

    PubMed Central

    2015-01-01

    PURPOSE To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non-quantitatively. RESULTS All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented. PMID:25932314

  14. Effect of salivary contamination and decontamination on bond strength of two one-step self-etching adhesives to dentin of primary and permanent teeth.

    PubMed

    Santschi, Katharina; Peutzfeldt, Anne; Lussi, Adrian; Flury, Simon

    2015-02-01

    To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin. Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests. Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.

  15. Contamination of dried blood spots - an underestimated risk in newborn screening.

    PubMed

    Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia

    2018-01-26

    Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.

  16. Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device.

    PubMed

    Rupp, Mark E; Cavalieri, R Jennifer; Marolf, Cole; Lyden, Elizabeth

    2017-07-15

    Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5-2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. NCT02102087. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  17. Air contamination for predicting wound contamination in clean surgery: A large multicenter study.

    PubMed

    Birgand, Gabriel; Toupet, Gaëlle; Rukly, Stephane; Antoniotti, Gilles; Deschamps, Marie-Noelle; Lepelletier, Didier; Pornet, Carole; Stern, Jean Baptiste; Vandamme, Yves-Marie; van der Mee-Marquet, Nathalie; Timsit, Jean-François; Lucet, Jean-Christophe

    2015-05-01

    The best method to quantify air contamination in the operating room (OR) is debated, and studies in the field are controversial. We assessed the correlation between 2 types of air sampling and wound contaminations before closing and the factors affecting air contamination. This multicenter observational study included 13 ORs of cardiac and orthopedic surgery in 10 health care facilities. For each surgical procedure, 3 microbiologic air counts, 3 particles counts of 0.3, 0.5, and 5 μm particles, and 1 bacteriologic sample of the wound before skin closure were performed. We collected data on surgical procedures and environmental characteristics. Of 180 particle counts during 60 procedures, the median log10 of 0.3, 0.5, and 5 μm particles was 7 (interquartile range [IQR], 6.2-7.9), 6.1 (IQR, 5.4-7), and 4.6 (IQR, 0-5.2), respectively. Of 180 air samples, 50 (28%) were sterile, 90 (50%) had 1-10 colony forming units (CFU)/m(3) and 40 (22%) >10 CFU/m(3). In orthopedic and cardiac surgery, wound cultures at closure were sterile for 24 and 9 patients, 10 and 11 had 1-10 CFU/100 cm(2), and 0 and 6 had >10 CFU/100 cm(2), respectively (P < .01). Particle sizes and a turbulent ventilation system were associated with an increased number of air microbial counts (P < .001), but they were not associated with wound contamination (P = .22). This study suggests that particle counting is a good surrogate of airborne microbiologic contamination in the OR. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Infection control practices for dental radiography.

    PubMed

    Palenik, Charles John

    2004-06-01

    Infection control for dental radiography employs the same materials, processes, and techniques used in the operatory, yet unless proper procedures are established and followed, there is a definite potential for cross-contamination to clinical area surfaces and DHCP. In general, the aseptic practices used are relatively simple and inexpensive, yet they require complete application in every situation.

  19. Food and feed chemical contaminants in the European Union: Regulatory, scientific, and technical issues concerning chemical contaminants occurrence, risk assessment, and risk management in the European Union.

    PubMed

    Silano, Marco; Silano, Vittorio

    2017-07-03

    A priority of the European Union is the control of risks possibly associated with chemical contaminants in food and undesirable substances in feed. Following an initial chapter describing the main contaminants detected in food and undesirable substances in feed in the EU, their main sources and the factors which affect their occurrence, the present review focuses on the "continous call for data" procedure that is a very effective system in place at EFSA to make possible the exposure assessment of specific contaminants and undesirable substances. Risk assessment of contaminants in food atances in feed is carried currently in the European Union by the CONTAM Panel of EFSA according to well defined methodologies and in collaboration with competent international organizations and with Member States.

  20. Assessment of metal contaminations leaching out from recycling plastic bottles upon treatments.

    PubMed

    Cheng, Xiaoliang; Shi, Honglan; Adams, Craig D; Ma, Yinfa

    2010-08-01

    Heavy metal contaminants in environment, especially in drinking water, are always of great concern due to their health impact. Due to the use of heavy metals as catalysts during plastic syntheses, particularly antimony, human exposure to metal release from plastic bottles has been a serious concern in recent years. The aim and scope of this study were to assess metal contaminations leaching out from a series of recycling plastic bottles upon treatments. In this study, leaching concentrations of 16 metal elements were determined in 21 different types of plastic bottles from five commercial brands, which were made of recycling materials ranging from no. 1 to no. 7. Several sets of experiments were conducted to study the factors that could potentially affect the metal elements leaching from plastic bottles, which include cooling with frozen water, heating with boiling water, microwave, incubating with low-pH water, outdoor sunlight irradiation, and in-car storage. Heating and microwave can lead to a noticeable increase of antimony leaching relative to the controls in bottle samples A to G, and some even reached to a higher level than the maximum contamination level (MCL) of the US Environmental Protection Agency (USEPA) regulations. Incubation with low-pH water, outdoor sunlight irradiation, and in-car storage had no significant effect on antimony leaching relative to controls in bottle samples A to G, and the levels of antimony leaching detected were below 6 ppb which is the MCL of USEPA regulations. Cooling had almost no effect on antimony leaching based on our results. For the other interested 15 metal elements (Al, V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Ag, Cd, Ba, Tl, Pb), no significant leaching was detected or the level was far below the MCL of USEPA regulations in all bottle samples in this study. In addition, washing procedure did contribute to the antimony leaching concentration for polyethylene terephthalate (PET) bottles. The difference of antimony leaching concentration between washing procedure involved and no washing procedure involved (AC) was larger than zero for samples A to G. This interesting result showed that higher antimony concentration was detected in experiments with no washing procedures compared with those experiments with washing procedures. Our study results indicate that partial antimony leaching from PET bottles comes from contaminations on the surface of plastic during manufacturing process, while major antimony leaching comes from conditional changes. The results revealed that heating and microwaving enhance antimony leaching significantly in PET plastic bottles. Plastic bottle manufacturers should consider the contaminations during manufacturing process and washing bottles before first use was strongly recommended to remove those contaminants.

  1. TREATMENT PLANT EVALUATION FOR PARTICULATE CONTAMINANT REMOVAL

    EPA Science Inventory

    A general procedure is suggested for evaluating performance of water filtration plants. Plant operating records should be reviewed. Plant hydraulics should be evaluated. Chemical feed pumps, measuring, and additional points, plus control of chemical doses, are discussed. Rapid mi...

  2. Apparel for Cleaner Clean Rooms

    NASA Technical Reports Server (NTRS)

    1983-01-01

    In the 1960s NASA pioneered contamination control technology, providing a base from which aerospace contractors could develop control measures. NASA conducted special courses for clean room technicians and supervisors, and published a series of handbooks with input from various NASA field centers. These handbooks extended aerospace experience to the medical, pharmaceutical, electronics, and other industries where extreme cleanliness is important. American Hospital Supply Company (AHSC) felt that high technology products with increasingly stringent operating requirements in aerospace, electronics, pharmaceuticals and medical equipment manufacturing demanded improvement in contamination control techniques. After studying the NASA handbooks and visiting NASA facilities, the wealth of information gathered resulted in Micro-clean non-woven garments and testing equipment and procedures for evaluating effectiveness.

  3. Principles of Sterilization of Mars Descent Vehicle Elements

    NASA Astrophysics Data System (ADS)

    Trofimov, Vladislav; Deshevaya, Elena; Khamidullina, N.; Kalashnikov, Viktor

    Due to COSPAR severe requirements to permissible microbiological contamination of elements of down-to-Mars S/C as well as complexity of their chemical composition and structure the exposure of such S/C elements to antimicrobial treatment (sterilization) at their integration requires application of a wide set of methods: chemical, ultraviolet, radiation. The report describes the analysis of all the aspects of applicable methods of treatment for cleaning of elements’ surfaces and inner contents from microbiota. The analysis showed that the most important, predictable and controllable method is radiation processing (of the elements which don’t change their properties after effective treatment). The experience of ionizing radiation application for sterilization of products for medicine, etc. shows that, depending on initial microbial contamination of lander elements, the required absorbed dose can be within the range 12 ÷ 35 kGr. The analysis of the effect of irregularity of radiation absorption in complex structure elements to the choice of radiation methodology was made and the algorithm of the choice of effective conditions of radiation treatment and control of sterilization efficiency was suggested. The important phase of establishing of the effective condition of each structure element treatment is experimental verification of real microbiological contamination in terms of S/C integration, contamination maximum decrease using another cleaning procedures (mechanical, chemical, ultraviolet) and determination of radiation resistance of spore microorganisms typical for the shops of space technology manufacturing and assembling. Proceeding from three parameters (irregularity of radiation absorption in a concrete element, its initial microbial contamination and resistance of microorganisms to the effect of radiation) the condition of the packed object sterilization is chosen, the condition that prevents secondary contamination, ensures given reliability of the treatment without final experimental microbiological verification only by simple control of the absorbed dose at critical points. All the process phases (from the choice of treatment conditions to provision of the procedure safety) are strictly regulated by Russian legislation in accordance with international standards.

  4. Evaluation of the microbicidal efficacy of Steris System I for digestive endoscopes using GERMANDE and ASTM validation protocols.

    PubMed

    Duc, D L; Ribiollet, A; Dode, X; Ducel, G; Marchetti, B; Calop, J

    2001-06-01

    In the light of more and more invasive procedures being carried out in digestive endoscopy using sterile devices, it appears necessary to put in place a process of endoscope reprocessing capable of ensuring the complete elimination of micro-organisms contaminating the device. We undertook a study of the microbial efficacy of STERIS SYSTEM 1 (SS1) which purports to achieve this objective. The channels of a gastroscope and a colonoscope were contaminated with suspensions of Pseudomonas aeruginosa, Aspergillus niger and Bacillus subtilis spores. Two procedures were then followed: (1) manual washing only, and (2) treatment in SS1 without prewashing. Recoveries of organisms were made from each channel according to a standard methodology to discover any survivors. Contamination controls we re assessed to measure the logarithmic reduction between the initial contamination and that recovered from the channels. Six cycles per micro-organisms, per type of endoscope, and per type of procedure were carried out. From an initial contamination leve l of 10(6) micro-organisms per endoscope, no micro-organisms were recovered in 35 of the 36 cycles with the SS1. In one cycle with the colonoscope, three B. subtilis organisms were recovered from the channels. Washing only gave microbial reductions which varied according to the micro-organism tested. The maximum reduction with washing alone was by a factor of 10(3 +/- 0.1)for B. subtilis and the minimum reduction factor was 10(3 +/- 0.3)for P. aeruginosa. Considering the results obtained with SS1 without prewashing and the efficacy obtained from washing only, the washing step offers an additional antimicrobial assurance reduction factor of between 10 and 103.1. This study shows that SS1, integrated into an overall reprocessing procedure for digestive endoscopes, is capable of delivering the complete elimination of contaminating micro-organisms in a reduced time and eliminates the toxic risk of reprocessing associated with aldehyde based disinfectants. Copyright 2001 The Hospital Infection Society.

  5. Comparison of contamination of femoral heads and pre-processed bone chips during hip revision arthroplasty.

    PubMed

    Mathijssen, N M C; Sturm, P D; Pilot, P; Bloem, R M; Buma, P; Petit, P L; Schreurs, B W

    2013-12-01

    With bone impaction grafting, cancellous bone chips made from allograft femoral heads are impacted in a bone defect, which introduces an additional source of infection. The potential benefit of the use of pre-processed bone chips was investigated by comparing the bacterial contamination of bone chips prepared intraoperatively with the bacterial contamination of pre-processed bone chips at different stages in the surgical procedure. To investigate baseline contamination of the bone grafts, specimens were collected during 88 procedures before actual use or preparation of the bone chips: in 44 procedures intraoperatively prepared chips were used (Group A) and in the other 44 procedures pre-processed bone chips were used (Group B). In 64 of these procedures (32 using locally prepared bone chips and 32 using pre-processed bone chips) specimens were also collected later in the procedure to investigate contamination after use and preparation of the bone chips. In total, 8 procedures had one or more positive specimen(s) (12.5 %). Contamination rates were not significantly different between bone chips prepared at the operating theatre and pre-processed bone chips. In conclusion, there was no difference in bacterial contamination between bone chips prepared from whole femoral heads in the operating room and pre-processed bone chips, and therefore, both types of bone allografts are comparable with respect to risk of infection.

  6. UV irradiation and autoclave treatment for elimination of contaminating DNA from laboratory consumables.

    PubMed

    Gefrides, Lisa A; Powell, Mark C; Donley, Michael A; Kahn, Roger

    2010-02-01

    Laboratories employ various approaches to ensure that their consumables are free of DNA contamination. They may purchase pre-treated consumables, perform quality control checks prior to casework, and use in-house profile databases for contamination detection. It is better to prevent contamination prior to DNA typing than identify it after samples are processed. To this end, laboratories may UV irradiate or autoclave consumables prior to use but treatment procedures are typically based on killing microorganisms and not on the elimination of DNA. We report a systematic study of UV and autoclave treatments on the persistence of DNA from saliva. This study was undertaken to determine the best decontamination strategy for the removal of DNA from laboratory consumables. We have identified autoclave and UV irradiation procedures that can eliminate nanogram quantities of contaminating DNA contained within cellular material. Autoclaving is more effective than UV irradiation because it can eliminate short fragments of contaminating DNA more effectively. Lengthy autoclave or UV irradiation treatments are required. Depending on bulb power, a UV crosslinker may take a minimum of 2h to achieve an effective dose for elimination of nanogram quantities of contaminating DNA (>7250mJ/cm(2)). Similarly autoclaving may also take 2h to eliminate similar quantities of contaminating DNA. For this study, we used dried saliva stains to determine the effective dose. Dried saliva stains were chosen because purified DNA as well as fresh saliva are less difficult to eradicate than dried stains and also because consumable contamination is more likely to be in the form of a collection of dry cells.

  7. 76 FR 29767 - Preventive Controls for Registered Human Food and Animal Food/Feed Facilities; Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-23

    ... associated with specific types of food or specific methods of manufacturing, processing, packing, or holding... specific methods of manufacturing, processing, packing, or holding food. In particular, we welcome input on... controls (e.g., procedures and practices utilized to minimize the risk of contamination) for human food and...

  8. Development of a new class of chemical and biological ultrasensors: Ribonuclease contamination and control

    NASA Technical Reports Server (NTRS)

    1984-01-01

    In order to define ribonuclease contamination, an assay for ribonuclease having picogram level sensitivity was established. In this assay, polycytidylic acid is digested by ribonuclease leading to smaller fragments of poly C that remain soluble after treatment of the sample with perchloric acid and lanthanum acetate. An absorbance measurement at 260 nm of the supernatant from the centrifuged sample measures the ribonuclease. A standard curve is shown. Using this assay procedure, ribonuclease contamination was found to be significant in routine laboratory proteins, in particular, bovine serum albumin, lysozyme, catalase, and cytochrome C. This was confirmed by demonstrating a considerable reduction in this activity in the presence of phosphate buffer since phosphate inhibits ribonuclease. Ribonuclease contamination was not significantly encountered in routine laboratory glassware, plasticware, column surfaces, chromatographic particles, and buffer reagents, including airborne contamination. Some contamination could be introduced by fingerprints, however.

  9. Cell culture contamination.

    PubMed

    Stacey, Glyn N

    2011-01-01

    Microbial contamination is a major issue in cell culture, but there are a range of procedures which can be adopted to prevent or eliminate contamination. Contamination may arise from the operator and the laboratory environment, from other cells used in the laboratory, and from reagents. Some infections may present a risk to laboratory workers: containment and aseptic technique are the key defence against such risks. Remedial management of suspected infection may simply mean discarding a single potentially infected culture. However, if a more widespread problem is identified, then all contaminated cultures and associated unused media that have been opened during this period should be discarded, equipment should be inspected and cleaned, cell culture operations reviewed, and isolation from other laboratories instituted until the problem is solved. Attention to training of staff, laboratory layout, appropriate use of quarantine for new cultures or cell lines, cleaning and maintenance, and quality control are important factors in preventing contamination in cell culture laboratories.

  10. Colling Wipe Samples for VX Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  11. Performance evaluation of a mitogenome capture and Illumina sequencing protocol using non-probative, case-type skeletal samples: Implications for the use of a positive control in a next-generation sequencing procedure.

    PubMed

    Marshall, Charla; Sturk-Andreaggi, Kimberly; Daniels-Higginbotham, Jennifer; Oliver, Robert Sean; Barritt-Ross, Suzanne; McMahon, Timothy P

    2017-11-01

    Next-generation ancient DNA technologies have the potential to assist in the analysis of degraded DNA extracted from forensic specimens. Mitochondrial genome (mitogenome) sequencing, specifically, may be of benefit to samples that fail to yield forensically relevant genetic information using conventional PCR-based techniques. This report summarizes the Armed Forces Medical Examiner System's Armed Forces DNA Identification Laboratory's (AFMES-AFDIL) performance evaluation of a Next-Generation Sequencing protocol for degraded and chemically treated past accounting samples. The procedure involves hybridization capture for targeted enrichment of mitochondrial DNA, massively parallel sequencing using Illumina chemistry, and an automated bioinformatic pipeline for forensic mtDNA profile generation. A total of 22 non-probative samples and associated controls were processed in the present study, spanning a range of DNA quantity and quality. Data were generated from over 100 DNA libraries by ten DNA analysts over the course of five months. The results show that the mitogenome sequencing procedure is reliable and robust, sensitive to low template (one ng control DNA) as well as degraded DNA, and specific to the analysis of the human mitogenome. Haplotypes were overall concordant between NGS replicates and with previously generated Sanger control region data. Due to the inherent risk for contamination when working with low-template, degraded DNA, a contamination assessment was performed. The consumables were shown to be void of human DNA contaminants and suitable for forensic use. Reagent blanks and negative controls were analyzed to determine the background signal of the procedure. This background signal was then used to set analytical and reporting thresholds, which were designated at 4.0X (limit of detection) and 10.0X (limit of quantiation) average coverage across the mitogenome, respectively. Nearly all human samples exceeded the reporting threshold, although coverage was reduced in chemically treated samples resulting in a ∼58% passing rate for these poor-quality samples. A concordance assessment demonstrated the reliability of the NGS data when compared to known Sanger profiles. One case sample was shown to be mixed with a co-processed sample and two reagent blanks indicated the presence of DNA above the analytical threshold. This contamination was attributed to sequencing crosstalk from simultaneously sequenced high-quality samples to include the positive control. Overall this study demonstrated that hybridization capture and Illumina sequencing provide a viable method for mitogenome sequencing of degraded and chemically treated skeletal DNA samples, yet may require alternative measures of quality control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Tissue recovery practices and bioburden: a systematic review.

    PubMed

    Brubaker, S; Lotherington, K; Zhao, Jie; Hamilton, B; Rockl, G; Duong, A; Garibaldi, A; Simunovic, N; Alsop, D; Dao, D; Bessemer, R; Ayeni, O R

    2016-12-01

    For successful transplantation, allografts should be free of microorganisms that may cause harm to the allograft recipient. Before or during recovery and subsequent processing, tissues can become contaminated. Effective tissue recovery methods, such as minimizing recovery times (<24 h after death) and the number of experienced personnel performing recovery, are examples of factors that can affect the rate of tissue contamination at recovery. Additional factors, such as minimizing the time after asystole to recovery and the total time it takes to perform recovery, the type of recovery site, the efficacy of the skin prep performed immediately prior to recovery of tissue, and certain technical recovery procedures may also result in control of the rate of contamination. Due to the heterogeneity of reported recovery practices and experiences, it cannot be concluded if the use of other barriers and/or hygienic precautions to avoid contamination have had an effect on bioburden detected after tissue recovery. Qualified studies are lacking which indicates a need exists for evidence-based data to support methods that reduce or control bioburden.

  13. A contaminant-free assessment of Endogenous Retroviral RNA in human plasma

    PubMed Central

    Karamitros, Timokratis; Paraskevis, Dimitrios; Hatzakis, Angelos; Psichogiou, Mina; Elefsiniotis, Ioannis; Hurst, Tara; Geretti, Anna-Maria; Beloukas, Apostolos; Frater, John; Klenerman, Paul; Katzourakis, Aris; Magiorkinis, Gkikas

    2016-01-01

    Endogenous retroviruses (ERVs) comprise 6–8% of the human genome. HERVs are silenced in most normal tissues, up-regulated in stem cells and in placenta but also in cancer and HIV-1 infection. Crucially, there are conflicting reports on detecting HERV RNA in non-cellular clinical samples such as plasma that suggest the study of HERV RNA can be daunting. Indeed, we find that the use of real-time PCR in a quality assured clinical laboratory setting can be sensitive to low-level proviral contamination. We developed a mathematical model for low-level contamination that allowed us to design a laboratory protocol and standard operating procedures for robust measurement of HERV RNA. We focus on one family, HERV-K HML-2 (HK2) that has been most recently active even though they invaded our ancestral genomes almost 30 millions ago. We extensively validated our experimental design on a model cell culture system showing high sensitivity and specificity, totally eliminating the proviral contamination. We then tested 236 plasma samples from patients infected with HIV-1, HCV or HBV and found them to be negative. The study of HERV RNA for human translational studies should be performed with extensively validated protocols and standard operating procedures to control the widespread low-level human DNA contamination. PMID:27640347

  14. Hospital-acquired Legionella infections: an update on the procedures for controlling environmental contamination.

    PubMed

    Borella, P; Bargellini, A; Marchegiano, P; Vecchi, E; Marchesi, I

    2016-01-01

    The waterborne healthcare-associated infections are mainly sustained by Legionella and Pseudomonas spp. Various water factors and plumbing characteristics, and the interaction with other water microorganisms are considered to be predictive of Legionella contamination. It is therefore mandatory to organize plans of surveillance, prevention and control in order to avoid disease appearance in immunosuppressed patients, with higher risk of death. Guidelines for the prevention of Legionnaires' disease have been published, benefiting those who face this problem, but definitive standardized solutions do not exist yet. Here we describe fifteen years of activity, during which our study group gathered interesting data on the control of Legionella contamination. Water disinfection is not generally sufficient to control the risk of infection, but a complex water safety plan should be developed, including system maintenance, training of staff and implementation of a clinical surveillance system aimed at early detection of cases. Concerning the control measures, we evaluated the effectiveness of different treatments suggested to reduce Legionella spp contamination, comparing our results with the current literature data. The performance ranking was highest for the filter, followed by boilers at high temperature, monochloramine and, at a lower level, chlorine dioxide; the effectiveness of hyperchlorination was limited, and thermal shock was even more ineffective.

  15. Sources of uncertainty in the quantification of genetically modified oilseed rape contamination in seed lots.

    PubMed

    Begg, Graham S; Cullen, Danny W; Iannetta, Pietro P M; Squire, Geoff R

    2007-02-01

    Testing of seed and grain lots is essential in the enforcement of GM labelling legislation and needs reliable procedures for which associated errors have been identified and minimised. In this paper we consider the testing of oilseed rape seed lots obtained from the harvest of a non-GM crop known to be contaminated by volunteer plants from a GM herbicide tolerant variety. The objective was to identify and quantify the error associated with the testing of these lots from the initial sampling to completion of the real-time PCR assay with which the level of GM contamination was quantified. The results showed that, under the controlled conditions of a single laboratory, the error associated with the real-time PCR assay to be negligible in comparison with sampling error, which was exacerbated by heterogeneity in the distribution of GM seeds, most notably at a small scale, i.e. 25 cm3. Sampling error was reduced by one to two thirds on the application of appropriate homogenisation procedures.

  16. The use of a modified technique to reduce radioactive air contamination in aerosol lung ventilation imaging.

    PubMed

    Avison, M; Hart, G

    2001-06-01

    The aim of this study was to reduce airborne contamination resulting from the use of aerosols in lung ventilation scintigraphy. Lung ventilation imaging is frequently performed with 99mTc-diethylenetriaminepentaacetate aerosol (DTPA), derived from a commercial nebuliser. Airborne contamination is a significant problem with this procedure; it results in exposure of staff to radiation and can reduce gamma camera performance when the ventilation is performed in the camera room. We examined the level of airborne contamination resulting from the standard technique with one of the most popular nebuliser kits and tested a modification which significantly reduced airborne contamination. Air contamination was measured while ventilating 122 patients. The modified technique reduced air contamination by a mean value of 64% (p = 0.028) compared with the standard control technique. Additionally, differences in contamination were examined when a mask or mouthpiece was used as well as differences between operators. A simplified method of monitoring air contamination is presented using a commonly available surface contamination monitor. The index so derived was proportional to air contamination (r = 0.88). The problems and regulations associated with airborne contamination are discussed.

  17. Guidelines To Validate Control of Cross-Contamination during Washing of Fresh-Cut Leafy Vegetables.

    PubMed

    Gombas, D; Luo, Y; Brennan, J; Shergill, G; Petran, R; Walsh, R; Hau, H; Khurana, K; Zomorodi, B; Rosen, J; Varley, R; Deng, K

    2017-02-01

    The U.S. Food and Drug Administration requires food processors to implement and validate processes that will result in significantly minimizing or preventing the occurrence of hazards that are reasonably foreseeable in food production. During production of fresh-cut leafy vegetables, microbial contamination that may be present on the product can spread throughout the production batch when the product is washed, thus increasing the risk of illnesses. The use of antimicrobials in the wash water is a critical step in preventing such water-mediated cross-contamination; however, many factors can affect antimicrobial efficacy in the production of fresh-cut leafy vegetables, and the procedures for validating this key preventive control have not been articulated. Producers may consider three options for validating antimicrobial washing as a preventive control for cross-contamination. Option 1 involves the use of a surrogate for the microbial hazard and the demonstration that cross-contamination is prevented by the antimicrobial wash. Option 2 involves the use of antimicrobial sensors and the demonstration that a critical antimicrobial level is maintained during worst-case operating conditions. Option 3 validates the placement of the sensors in the processing equipment with the demonstration that a critical antimicrobial level is maintained at all locations, regardless of operating conditions. These validation options developed for fresh-cut leafy vegetables may serve as examples for validating processes that prevent cross-contamination during washing of other fresh produce commodities.

  18. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.

    PubMed

    Makki, D; Deierl, K; Pandit, A; Trakru, S

    2014-09-01

    The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.

  19. Method for the Collection, Gravimetric and Chemical Analysis of Nonvolatile Residue (NVR) on Surfaces

    NASA Technical Reports Server (NTRS)

    Gordon, Keith; Rutherford, Gugu; Aranda, Denisse

    2017-01-01

    Nonvolatile residue (NVR), sometimes referred to as molecular contamination is the term used for the total composition of the inorganic and high boiling point organic components in particulates and molecular films deposited on critical surfaces surrounding space structures, with the particulate and NVR contamination originating primarily from pre-launch operations. The "nonvolatile" suggestion from the terminology NVR implies that the collected residue will not experience much loss under ambient conditions. NVR has been shown to have a dramatic impact on the ability to perform optical measurements from platforms based in space. Such contaminants can be detected early by the controlled application of various detection techniques and contamination analyses. Contamination analyses are the techniques used to determine if materials, components, and subsystems can be expected to meet the performance requirements of a system. Of particular concern is the quantity of NVR contaminants that might be deposited on critical payload surfaces from these sources. Subsequent chemical analysis of the contaminant samples by infrared spectroscopy and gas chromatography mass spectrometry identifies the components, gives semi-quantitative estimates of contaminant thickness, indicates possible sources of the NVR, and provides guidance for effective cleanup procedures. In this report, a method for the collection and determination of the mass of NVR was generated by the authors at NASA Langley Research Center. This report describes the method developed and implemented for collecting NVR contaminants, and procedures for gravimetric and chemical analysis of the residue obtained. The result of this NVR analysis collaboration will help pave the way for Langley's ability to certify flight hardware outgassing requirements in support of flight projects such as Stratospheric Aerosol and Gas Experiment III (SAGE III), Clouds and the Earth's Radiant Energy System (CERES), Materials International Space Station Experiment - X (MISSE-X), and Doppler Aerosol Wind Lidar (DAWN).

  20. Development of Ecological Toxicity and Biomagnification Data for Explosives Contaminants in Soil

    DTIC Science & Technology

    2003-07-01

    explosive contaminated soil leachates to Daphnia magna using an adapted toxicity characteristic leaching procedure. U.S. Army Chemical and Biological...1993) Toxicity determination of explosive contaminated soil leachates to Daphnia magna using an adapted toxicity characteristic leaching procedure...Sadusky, M. (1993). Toxicity determination of explosive contaminated soil leachates to Daphnia magna using C-46 an adapted toxicity

  1. 76 FR 37014 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...; Analysis and Sampling Procedures AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY... Contaminants Under the Safe Drinking Water Act; Analysis and Sampling Procedures. 75 FR 32295. June 8, 2010...

  2. Contamination control program for the Cosmic Background Explorer

    NASA Technical Reports Server (NTRS)

    Barney, Richard D.

    1991-01-01

    Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

  3. What food and feeding rates are optimum for the Chironomus dilutus sediment toxicity test method?

    EPA Science Inventory

    Laboratory tests with benthic macroinvertebrates conducted using standard toxicity test procedures are used to assess the potential toxicity of contaminated sediments. Results are compared across sites or for batches of samples, and the performance of organisms in control treatme...

  4. The other side of the safety coin. [aerospace operations

    NASA Technical Reports Server (NTRS)

    Roth, Gilbert L.

    1986-01-01

    The development, inspection and testing requirements for successful production and launch and safe operation of spaceflight hardware are discussed. Emphasis is placed on paying acute attention to malfunctions, which could be caused by contaminants (particles in docking rings), insufficiently durable materials (Orbiter brakes), etc. Generic and specific problems which occur in propulsion, avionics, mechanical and computer systems and in configuration management, manufacturing and process control efforts are explored. Case histories of deficiencies found in LOX fuel lines, contaminated hydraulic control systems, the Solar Maximum Mission thermal insulation grommets, are summarized. Thorough inspection and testing procedures and design change recording during manufacture of spacecraft components are identified as requisites for successful space missions.

  5. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery

    PubMed Central

    Deierl, K; Pandit, A; Trakru, S

    2014-01-01

    Introduction The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. Methods During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon’s grade, the type of procedure, the role of the assistant and the dominance of the hand. Results A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1–5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Conclusions Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection. PMID:25198974

  6. Postoperative infections traced to contamination of an intravenous anesthetic, propofol.

    PubMed

    Bennett, S N; McNeil, M M; Bland, L A; Arduino, M J; Villarino, M E; Perrotta, D M; Burwen, D R; Welbel, S F; Pegues, D A; Stroud, L

    1995-07-20

    Between June 1990 and February 1993, the Centers for Disease Control and Prevention conducted investigations at seven hospitals because of unusual outbreaks of bloodstream infections, surgical-site infections, and acute febrile episodes after surgical procedures. We conducted case-control or cohort studies, or both, to identify risk factors. A case patient was defined as any patient who had an organism-specific infection or acute febrile episode after a surgical procedure during the study period in that hospital. The investigations also included reviews of procedures, cultures, and microbiologic studies of infecting, contaminating, and colonizing strains. Sixty-two case patients were identified, 49 (79 percent) of whom underwent surgery during an epidemic period. Postoperative complications were more frequent during the epidemic period than before it. Only exposure to propofol, a lipid-based anesthetic agent, was significantly associated with the postoperative complications at all seven hospitals. In six of the outbreaks, an etiologic agent (Staphylococcus aureus, Candida albicans, Moraxella osloensis, Enterobacter agglomerans, or Serratia marcescens) was identified, and the same strains were isolated from the case patients. Although cultures of unopened containers of propofol were negative, at two hospitals cultures of propofol from syringes currently in use were positive. At one hospital, the recovered organism was identical to the organism isolated from the case patients. Interviews with and observation of anesthesiology personnel documented a wide variety of lapses in aseptic techniques. With the increasing use of lipid-based medications, which support rapid bacterial growth at room temperature, strict aseptic techniques are essential during the handling of these agents to prevent extrinsic contamination and dangerous infectious complications.

  7. Bacterial Contamination During Diagnostic and Interventional Neuroangiography is a Frequent Finding: But Does It Matter? An Observational Study.

    PubMed

    Kabbasch, C; Dorn, F; Wenchel, H M; Krug, B; Mpotsaris, A; Liebig, T

    2017-03-01

    Bacterial contamination during angiographic procedures is a potential source of bacteremia. It is largely unknown whether it is clinically relevant. Our aim was to evaluate the incidence of contamination of liquids during catheter-based neuroangiographic examinations, the spectrum of microorganisms, a comparison of two different trolley-settings, and a follow-up of all patients with regard to clinical and lab signs of infection. A total of 170 patients underwent either diagnostic angiography (n = 111) or arterial neuroendovascular procedures (n = 59). To study the impact of airborne contamination of sterile liquids, we randomly assigned equal numbers of procedures to two distinct setups. Group A with standard open-surface bowls and group B with repetitive coverage of liquids throughout the procedure. Patient preparation was performed with utmost care. After each procedure, samples of the liquids were sent for microbiological evaluation. Patients were followed for signs of infection (fever, white blood cell count, C-reactive-protein). Of all samples, 25.3 % were contaminated. Contamination consisted of resident skin microbiota only and was more common with procedures (28.8 %) than with diagnostic angiography (23.4 %) and less common in uncovered (23.5 %) than in covered bowls (27.1 %). However, these differences were insignificant. None of the patients developed clinical or lab signs of infection. Contamination during diagnostic and interventional angiography does occur and cannot be avoided by intermittent coverage. Despite a surprisingly high incidence, our findings support the common strategy that antibiotic coverage is unnecessary in most patients undergoing arterial angiography as it lacks clinical impact. Airborne contamination does not appear to play a role.

  8. Occurrence of Non-Tuberculous Mycobacteria at an Acute Care Hospital Using Secondary Drinking Water Treatment

    EPA Science Inventory

    The development of infection control strategies at acute-care hospitals has contributed to an overall decline in the number of healthcare-associated infections (HAI’s) in the United States, especially those caused by contaminated equipment used in surgical procedures and co...

  9. 40 CFR 1065.660 - THC and NMHC determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false THC and NMHC determination. 1065.660... CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.660 THC and NMHC determination. (a) THC determination and THC/CH 4 initial contamination corrections. (1) If we require you to...

  10. Contamination control through filtration of microorganisms

    NASA Technical Reports Server (NTRS)

    Stabekis, P. D.; Lyle, R. G.

    1972-01-01

    A description is given of the various kinds of gas and liquid filters used in decontamination and sterilization procedures. Also discussed are filtration mechanisms, characteristics of filter materials, and the factors affecting filter performance. Summaries are included for filter testing and evaluation techniques and the possible application of the filters to spacecraft sterilization.

  11. [Blocking the spray of contaminants from patients' exhalent using a tracheal detecting bulb during endotracheal intubation].

    PubMed

    Tong, You-liang; Sun, Ming; Wang, Zhen; Li, Bin; Xie, Jue; Ye, Hui

    2011-11-01

    To examine the effect of a newly-developed tracheal detecting-bulb (TDB) in preventing the spray of contaminants in patients' exhalent during emergency endotracheal intubation procedure. 62 emergency patients (male or female, age 21-73 years, weight 47-83 kg, with different levels of consciousness and spontaneous breathing) were randomly divided into two groups (n =31 each) to receive endotracheal intubation by an anesthesiologist with more than 17 years of experience, with (TDB group) or without (control group) a TDB connected to the tracheal tubing. Records were taken regarding the patient's coughing, expansion / contraction of the TDB, the operator's feeling of the patient's exhalent on his face / neck and the contamination of these areas by blood / secretions from the patients in the due course. In TDB group, expansion / contraction of TDB occurred in all cases, but the operator felt no exhalent in any of them. In 9 cases the patients coughed but the operator was contaminated only in 2 cases. While in control group, the patients' exhalent was felt in 16 cases. Coughing were recorded in 7 cases, and the operator was contaminated in 11 cases. In comparison with the control group, TDB group had significantly lower(both P < 0.05), incidence in feeling the exhalent (0 vs. 16), and contamination by blood or secretions (2 vs. 11) although the two groups had no significant difference in the incidence of coughing (9 vs. 7, P > 0.05). TDB can play an important role in blocking the spray of contaminants in patients' exhalent during endotracheal intubation.

  12. Surface cleanliness measurement procedure

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  13. Microscope sterility during spine surgery.

    PubMed

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact with unsterile parts of the surgeon. Therefore, we believe that changing gloves after making adjustments to the optic eyepieces and avoid handling any portion of the drape above the eyepieces may decrease the risks of intraoperative contamination and possibly postoperative infection as well.

  14. A new approach for performing contamination control bakeouts in JPL thermal vacuum test chambers

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth R.; Taylor, Daniel M.; Lane, Robert W.; Cortez, Maximo G.; Anderson, Mark R.

    1992-01-01

    Contamination control requirements for the Wide Field/Planetary Camera II (WF/PC II) are necessarily stringent to protect against post-launch contamination of the sensitive optical surfaces, particularly the cold charge coupled device (CCD) imaging surfaces. Typically, thermal vacuum test chambers have employed a liquid nitrogen (LN2) cold trap to collect outgassed contaminants. This approach has the disadvantage of risking recontamination of the test article from shroud offgassing during post-test warmup of the chamber or from any shroud warming of even a few degrees during the bakeout process. By using an enclave, essentially a chamber within a chamber, configured concentrically and internally within an LN2 shroud, a method was developed, based on a design concept by Taylor, for preventing recontamination of test articles during bakeouts and subsequent post-test warmup of the vacuum chamber. Enclaves for testing WF/PC II components were designed and fabricated, then installed in three of JPL's Environmental Test Lab chambers. The design concepts, operating procedures, and test results of this development are discussed.

  15. An Efficient Multistrategy DNA Decontamination Procedure of PCR Reagents for Hypersensitive PCR Applications

    PubMed Central

    Pruvost, Mélanie; Bennett, E. Andrew; Grange, Thierry; Geigl, Eva-Maria

    2010-01-01

    Background PCR amplification of minute quantities of degraded DNA for ancient DNA research, forensic analyses, wildlife studies and ultrasensitive diagnostics is often hampered by contamination problems. The extent of these problems is inversely related to DNA concentration and target fragment size and concern (i) sample contamination, (ii) laboratory surface contamination, (iii) carry-over contamination, and (iv) contamination of reagents. Methodology/Principal Findings Here we performed a quantitative evaluation of current decontamination methods for these last three sources of contamination, and developed a new procedure to eliminate contaminating DNA contained in PCR reagents. We observed that most current decontamination methods are either not efficient enough to degrade short contaminating DNA molecules, rendered inefficient by the reagents themselves, or interfere with the PCR when used at doses high enough to eliminate these molecules. We also show that efficient reagent decontamination can be achieved by using a combination of treatments adapted to different reagent categories. Our procedure involves γ- and UV-irradiation and treatment with a mutant recombinant heat-labile double-strand specific DNase from the Antarctic shrimp Pandalus borealis. Optimal performance of these treatments is achieved in narrow experimental conditions that have been precisely analyzed and defined herein. Conclusions/Significance There is not a single decontamination method valid for all possible contamination sources occurring in PCR reagents and in the molecular biology laboratory and most common decontamination methods are not efficient enough to decontaminate short DNA fragments of low concentration. We developed a versatile multistrategy decontamination procedure for PCR reagents. We demonstrate that this procedure allows efficient reagent decontamination while preserving the efficiency of PCR amplification of minute quantities of DNA. PMID:20927390

  16. Surveillance of Environmental and Procedural Measures of Infection Control in the Operating Theatre Setting

    PubMed Central

    Raggi, Alessandra; Sanna, Tiziana; Mazzetti, Magda; Orsi, Alessandra; Zanni, Angela; Farruggia, Patrizia

    2017-01-01

    The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols. PMID:29283367

  17. Hyperspectral characterization of fluorescent organic contaminants on optical payloads

    NASA Astrophysics Data System (ADS)

    Bourcier, Frédéric; Pansu, Robert; Faye, Delphine; Le Nouy, Patrice; Spezzigu, Piero

    2017-11-01

    The increase of performance of new optical instruments for science and Earth observation always leads to higher requirements in terms of contamination due to particle sedimentation in cleanrooms and deposition of chemical species in vacuum environment. Specific cleanliness control procedures are implemented in order to mitigate the risks of contamination on optical sensors and sensitive diopters, especially when used for UV applications. Such procedures are commonly carried out in cleanrooms and are described in both European ECSS-Q-ST-70-50C and NASA SN-C-0005D standards. UV light at 365 nm is often used for the inspection of optical sensitive surfaces to localize and to evaluate the amount of fluorescent particles, essentially coming from textile fibers. But other groups of compounds can be observed with a different spectral response and distribution, like adhesives and resins or even organic residues. Therefore, we could take advantage of this spectral information closely linked to specific molecules for partial identification of these materials before further investigation involving wipe on flight model and measurement in a laboratory.

  18. Skin antiseptics in venous puncture site disinfection for preventing blood culture contamination: A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Liu, Wenjie; Duan, Yuchen; Cui, Wenyao; Li, Li; Wang, Xia; Dai, Heling; You, Chao; Chen, Maojun

    2016-07-01

    To compare the efficacy of several antiseptics in decreasing the blood culture contamination rate. Network meta-analysis. Electronic searches of PubMed and Embase were conducted up to November 2015. Only randomized controlled trials or quasi-randomized controlled trials were eligible. We applied no language restriction. A comprehensive review of articles in the reference lists was also accomplished for possible relevant studies. Relevant studies evaluating efficacy of different antiseptics in venous puncture site for decreasing the blood culture contamination rate were included. The data were extracted from the included randomized controlled trials by two authors independently. The risk of bias was evaluated using Detsky scale by two authors independently. We used WinBUGS1.43 software and statistic model described by Chaimani to perform this network meta-analysis. Then graphs of statistical results of WinBUGS1.43 software were generated using 'networkplot', 'ifplot', 'netfunnel' and 'sucra' procedure by STATA13.0. Odds ratio and 95% confidence intervals were assessed for dichotomous data. A probability of p less than 0.05 was considered to be statistically significant. Compared with ordinary meta-analyses, this network meta-analysis offered hierarchies for the efficacy of different antiseptics in decreasing the blood culture contamination rate. Seven randomized controlled trials involving 34,408 blood samples were eligible for the meta-analysis. No significant difference was found in blood culture contamination rate among different antiseptics. No significant difference was found between non-alcoholic antiseptics and alcoholic antiseptics, alcoholic chlorhexidine and povidone iodine, chlorhexidine and iodine compounds, povidone iodine and iodine tincture in this aspect, respectively. Different antiseptics may not affect the blood culture contamination rate. Different intervals between the skin disinfection and the venous puncture, the different settings (emergency room, medical wards, and intensive care units) and the performance of the phlebotomy may affect the blood culture contamination rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Decontamination and Management of Human Remains Following Incidents of Hazardous Chemical Release

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hauschild, Veronique; Watson, Annetta Paule; Bock, Robert Eldon

    2012-01-01

    Abstract Objective: To provide specific procedural guidance and resources for identification, assessment, control, and mitigation of compounds that may contaminate human remains resulting from chemical attack or release. Design: A detailed technical, policy, and regulatory review is summarized. Setting: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present. Settings would include sites of transportation accidents, natural disasters, terrorist or military operations, mortuary affairs or medical examiner processing and decontamination points, and similar. Patients, Participants: While recommended procedures have not been validated with actual human remains, guidance has been developed frommore » data characterizing controlled experiments with fabrics, materiel, and laboratory animals. Main Outcome Measure(s): Presentation of logic and specific procedures for remains management, protection and decontamination of mortuary affairs personnel, as well as decision criteria for determining when remains are sufficiently decontaminated so as to pose no chemical health hazard. Results: Established procedures and existing equipment/materiel available for decontamination and verification provide appropriate and reasonable means to mitigate chemical hazards from remains. Extensive characterization of issues related to remains decontamination indicates that supra-lethal concentrations of liquid chemical warfare agent VX may prove difficult to decontaminate and verify in a timely fashion. Specialized personnel can and should be called upon to assist with monitoring necessary to clear decontaminated remains for transport and processing. Conclusions: Once appropriate decontamination and verification have been accomplished, normal procedures for remains processing and transport to the decedent s family and the continental United States can be followed.« less

  20. Operations and maintenance manual, atmospheric contaminant sensor. Addendum 1: Carbon monoxide monitor model 204

    NASA Technical Reports Server (NTRS)

    1972-01-01

    An instrument for monitoring the carbon monoxide content of the ambient atmosphere is described. The subjects discussed are: (1) theory of operation, (2) system features, (3) controls and monitors, (4) operational procedures, and (5) maintenance and troubleshooting. Block drawings and circuit diagrams are included to clarify the text.

  1. 40 CFR 1065.660 - THC, NMHC, and CH4 determination.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false THC, NMHC, and CH4 determination. 1065... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.660 THC, NMHC, and CH4 determination. (a) THC determination and initial THC/CH 4 contamination corrections. (1) If we...

  2. 40 CFR 1065.660 - THC, NMHC, and CH4 determination.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false THC, NMHC, and CH4 determination. 1065... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.660 THC, NMHC, and CH4 determination. (a) THC determination and initial THC/CH 4 contamination corrections. (1) If we...

  3. 40 CFR 1065.660 - THC, NMHC, and CH4 determination.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false THC, NMHC, and CH4 determination. 1065... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.660 THC, NMHC, and CH4 determination. (a) THC determination and initial THC/CH 4 contamination corrections. (1) If we...

  4. 40 CFR 1065.660 - THC, NMHC, and CH4 determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false THC, NMHC, and CH4 determination. 1065... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calculations and Data Requirements § 1065.660 THC, NMHC, and CH4 determination. (a) THC determination and THC/CH 4 initial contamination corrections. (1) If we...

  5. An unwanted visitor. Aggressive infection control strategies are needed to shorten the hospital visit of the easily spread norovirus.

    PubMed

    Albers, Marilyn K

    2004-11-01

    Norovirus is the name for a group of Norwalk-like viruses that cause acute gastroenteritis of rapid onset. A recent outbreak at a tertiary care facility in Alberta provided an opportunityfor staff and management to review their outbreak protocol and improve their infection prevention and control procedures. The outbreak caused illness in 32 of 73 exposed patients as well as 42 staff members. None of the infected patients or staff developed complications. The source of norovirus contamination was probably associated with a symptomatic food services staff member serving food cafeteria style in a satellite patient dining room. Food service procedures and serving techniques were reviewed; although no breaks in technique were identified, correct food handling procedures were reviewed with staff. Subsequent patient and staff cases were probably related to the cross contamination of environmental surfaces and patient care equipment. The director of nursing and the infection control practitioner led the investigation and management of the outbreak. An Outbreak Management Committee was also formed to reinforce routine infection prevention practices and implement infection control strategies. Communication strategies for staff, patients and visitors were quickly devised and implemented. Gaps in the outbreak protocol were identified and resolved promptly Four permanent changes were made: the use of alcohol hand rinse in designated locations; the development of a comprehensive e-mail to facilitate site-wide communication; the development of teamwork checklists and accountabilities; and the establishment of criteria for use in outbreak situations to proactively determine essential and non-essential therapies and treatments.

  6. Consequences of Decontamination Procedures in Forensic Hair Analysis Using Metal-Assisted Secondary Ion Mass Spectrometry Analysis.

    PubMed

    Cuypers, Eva; Flinders, Bryn; Boone, Carolien M; Bosman, Ingrid J; Lusthof, Klaas J; Van Asten, Arian C; Tytgat, Jan; Heeren, Ron M A

    2016-03-15

    Today, hair testing is considered to be the standard method for the detection of chronic drug abuse. Nevertheless, the differentiation between systemic exposure and external contamination remains a major challenge in the forensic interpretation of hair analysis. Nowadays, it is still impossible to directly show the difference between external contamination and use-related incorporation. Although the effects of washing procedures on the distribution of (incorporated) drugs in hair remain unknown, these decontamination procedures prior to hair analysis are considered to be indispensable in order to exclude external contamination. However, insights into the effect of decontamination protocols on levels and distribution of drugs incorporated in hair are essential to draw the correct forensic conclusions from hair analysis; we studied the consequences of these procedures on the spatial distribution of cocaine in hair using imaging mass spectrometry. Additionally, using metal-assisted secondary ion mass spectrometry, we are the first to directly show the difference between cocaine-contaminated and user hair without any prior washing procedure.

  7. Efficacy of home washing methods in controlling surface microbial contamination on fresh produce.

    PubMed

    Kilonzo-Nthenge, Agnes; Chen, Fur-Chi; Godwin, Sandria L

    2006-02-01

    Much effort has been focused on sanitation of fresh produce at the commercial level; however, few options are available to the consumer. The purpose of this study was to determine the efficacy of different cleaning methods in reducing bacterial contamination on fresh produce in a home setting. Lettuce, broccoli, apples, and tomatoes were inoculated with Listeria innocua and then subjected to combinations of the following cleaning procedures: (i) soak for 2 min in tap water, Veggie Wash solution, 5% vinegar solution, or 13% lemon solution and (ii) rinse under running tap water, rinse and rub under running tap water, brush under running tap water, or wipe with wet/dry paper towel. Presoaking in water before rinsing significantly reduced bacteria in apples, tomatoes, and lettuce, but not in broccoli. Wiping apples and tomatoes with wet or dry paper towel showed lower bacterial reductions compared with soaking and rinsing procedures. Blossom ends of apples were more contaminated than the surface after soaking and rinsing; similar results were observed between flower section and stem of broccoli. Reductions of L. innocua in both tomatoes and apples (2.01 to 2.89 log CFU/g) were more than in lettuce and broccoli (1.41 to 1.88 log CFU/g) when subjected to same washing procedures. Reductions of surface contamination of lettuce after soaking in lemon or vinegar solutions were not significantly different (P > 0.05) from lettuce soaking in cold tap water. Therefore, educators and extension workers might consider it appropriate to instruct consumers to rub or brush fresh produce under cold running tap water before consumption.

  8. Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions.

    PubMed

    Eder, Anne F; Dy, Beth A; DeMerse, Barbara; Wagner, Stephen J; Stramer, Susan L; O'Neill, E Mary; Herron, Ross M

    2017-12-01

    Apheresis technology to collect platelet (PLT) components differs among devices. We evaluated the relationship of the plateletpheresis device with bacterial contamination and reported septic transfusion reactions. Plateletpheresis was performed using Amicus (Fenwal, a Fresenius Kabi Company) or Trima (Trima Accel, TerumoBCT) from 2010 to 2014. All donations used inlet-line sample diversion and were tested by quality control (QC; Day 1) aerobic culture. Rates of bacterial contamination and septic reactions to PLTs were calculated for both devices. During the 5-year study period, plateletpheresis collections using Amicus and Trima devices totaled 1,486,888 and 671,955 donations, respectively. The rate of confirmed-positive bacterial cultures of apheresis PLT donations was significantly higher with Amicus than with Trima (252 vs. 112 per 10 6 donations [odds ratio {OR}, 2.3; 95% confidence interval {CI}, 1.8-2.9]). Septic transfusion reactions were caused by 30 apheresis PLT units from 25 contaminated Amicus procedures and three apheresis PLT units from three contaminated Trima procedures. The overall rate of septic reactions was significantly higher with apheresis PLT components collected with Amicus than with Trima (16.8 vs. 4.5 per 10 6 donations [OR, 3.8; 95% CI, 1.1-12.5]). All apheresis PLT components implicated in septic transfusion reactions had negative QC culture results incubated through Day 5 (i.e., false negatives). Apheresis technology affects bacterial contamination of plateletpheresis collections. The device-specific, higher rate of confirmed-positive bacterial culture results also correlated with a significantly higher rate of reported septic transfusion reactions to apheresis PLTs. © 2017 AABB.

  9. Bacterial Contamination in Tips of Electrocautery Devices During Total Hip Arthroplasty.

    PubMed

    Shahi, Alisina; Chen, Antonia F; McKenna, Paul B; Roberts, Amity L; Manrique, Jorge; Belden, Katherine A; Austin, Matthew S

    2015-08-01

    Surgical equipment can become contaminated during surgery. It is unknown if electrocautery tips can become contaminated in clean orthopedic procedures despite the produced heat. Therefore, we conducted a prospective study to address this concern. The tips from 25 primary and 25 aseptic revision THAs were collected and an additional 5 sterile tips served as negative controls. Aerobic and anaerobic cultures were incubated for a minimum of 3 days. There were 3 positive cultures (6%); one in primary THA (4%) with Lactobacillus and Enterococcus faecalis; two among revisions (8%), one with E. faecalis and another one with alpha hemolytic streptococci and coagulase negative Staphylococcus. The mean exposure time of the contaminated tips was 132.3 minutes. Patients were followed for 90 days postoperatively and none of them developed surgical site infection. This is the first study to demonstrate that electrosurgical devices can become contaminated during THA in laminar flow equipped operating rooms. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques. [including computer programs and ultraviolet reflection analysis

    NASA Technical Reports Server (NTRS)

    Linford, R. M. F.; Allen, T. H.; Dillow, C. F.

    1975-01-01

    A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

  11. Virus, protozoa and organic compounds decay in depurated oysters.

    PubMed

    Souza, Doris Sobral Marques; Piazza, Rômi Sharon; Pilotto, Mariana Rangel; do Nascimento, Mariana de Almeida; Moresco, Vanessa; Taniguchi, Satie; Leal, Diego Averaldo Guiguet; Schmidt, Éder der Carlos; Cargin-Ferreira, Eduardo; Bícego, Márcia Caruso; Sasaki, Silvio Tarou; Montone, Rosalinda Carmela; de Araujo, Rafael Alves; Franco, Regina Maura Bueno; Bouzon, Zenilda Laurita; Bainy, Afonso Celso Dias; Barardi, Célia Regina Monte

    2013-11-01

    (1) Evaluate the dynamic of the depuration process of Crassostrea gigas oysters using different ultraviolet doses with different amounts of contaminants (virus, protozoa and organic contaminants) and (2) investigate the morphological changes in the oysters' tissues produced by the depuration procedures. The oysters were allocated in sites with different degrees of contamination and analyzed after 14 days. Some animals were used as positive controls by artificial bioaccumulation with HAdV2 and MNV1 and subjected to depuration assays using UV lamps (18 or 36 W) for 168 h. The following pollutants were researched in the naturally contaminated oysters, oysters after 14 days in sites and oysters during the depuration processes: virus (HAdV, HAV, HuNoV GI/GII and JCPyV), by (RT) qPCR; protozoa (Cryptosporidium and Giardia species), by immunomagnetic separation and immunofluorescence; and organic compounds (AHs, PAHs, LABs, PCBs and organochlorine pesticides-OCs), by chromatography. Changes in the oysters' tissues produced by the depuration processes were also evaluated using histochemical analysis by light microscopy. In the artificially bioaccumulated oysters, only HAdV2 and MNV1 were investigated by (RT) qPCR before the depuration procedures and after 96 and 168 h of these procedures. At 14 days post-allocation, HAdV was found in all the sites (6.2 × 105 to 4.4 × 107 GC g(-1)), and Giardia species in only one site. Levels of PCBs and OCs in the oyster's tissues were below the detection limit for all samples. AHs (3.5 to 4.4 μg g(-1)), PAHs (11 to 191 ng g(-1)) and LABs (57 to 751 ng g(-1)) were detected in the samples from 3 sites. During the depuration assays, we found HAdV, Giardia and Cryptosporidium species until 168 h, independent of UV treatment. AHs, PAHs and LABs were found also after 168 h of depuration (36 W and without UV lamp). The depuration procedures did not produce changes in the oysters' tissues. In the artificially contaminated and depurated oysters, we detected HAdV until 168 h and MNV1 until 96 h of depuration. The applied depuration treatments were unable to eliminate the protozoa or to degrade the HAdV genomes but were able to degrade the MNV1 genomes. Similarly, the UV water treatment was not efficient for aliphatic hydrocarbons, PAHs and LABs, as their concentrations were equivalent or higher to the concentrations of the control samples and samples from depuration tanks without UV treatment. © 2013.

  12. Reducing Blood Culture Contamination in the Emergency Department: An Interrupted Time Series Quality Improvement Study

    PubMed Central

    Self, Wesley H.; Speroff, Theodore; Grijalva, Carlos G.; McNaughton, Candace D.; Ashburn, Jacki; Liu, Dandan; Arbogast, Patrick G.; Russ, Stephan; Storrow, Alan B.; Talbot, Thomas R.

    2012-01-01

    Objectives Blood culture contamination is a common problem in the emergency department (ED) that leads to unnecessary patient morbidity and health care costs. The study objective was to develop and evaluate the effectiveness of a quality improvement (QI) intervention for reducing blood culture contamination in an ED. Methods The authors developed a QI intervention to reduce blood culture contamination in the ED and then evaluated its effectiveness in a prospective interrupted times series study. The QI intervention involved changing the technique of blood culture specimen collection from the traditional clean procedure, to a new sterile procedure, with standardized use of sterile gloves and a new materials kit containing a 2% chlorhexidine skin antisepsis device, a sterile fenestrated drape, a sterile needle, and a procedural checklist. The intervention was implemented in a university-affiliated ED and its effect on blood culture contamination evaluated by comparing the biweekly percentages of blood cultures contaminated during a 48-week baseline period (clean technique), and 48-week intervention period (sterile technique), using segmented regression analysis with adjustment for secular trends and first-order autocorrelation. The goal was to achieve and maintain a contamination rate below 3%. Results During the baseline period, 321 out of 7,389 (4.3%) cultures were contaminated, compared to 111 of 6,590 (1.7%) during the intervention period (p < 0.001). In the segmented regression model, the intervention was associated with an immediate 2.9% (95% CI = 2.2% to 3.2%) absolute reduction in contamination. The contamination rate was maintained below 3% during each biweekly interval throughout the intervention period. Conclusions A QI assessment of ED blood culture contamination led to development of a targeted intervention to convert the process of blood culture collection from a clean to a fully sterile procedure. Implementation of this intervention led to an immediate and sustained reduction of contamination in an ED with a high baseline contamination rate. PMID:23570482

  13. Containment wells to form hydraulic barriers along site boundaries.

    PubMed

    Vo, D; Ramamurthy, A S; Qu, J; Zhao, X P

    2008-12-15

    In the field, aquifer remediation methods include pump and treat procedures based on hydraulic control systems. They are used to reduce the level of residual contamination present in the soil and soil pores of aquifers. Often, physical barriers are erected along the boundaries of the target (aquifer) site to reduce the leakage of the released soil contaminant to the surrounding regions. Physical barriers are expensive to build and dismantle. Alternatively, based on simple hydraulic principles, containment wells or image wells injecting clear water can be designed and built to provide hydraulic barriers along the contaminated site boundaries. For brevity, only one pattern of containment well system that is very effective is presented in detail. The study briefly reports about the method of erecting a hydraulic barrier around a contaminated region based on the simple hydraulic principle of images. During the clean-up period, hydraulic barriers can considerably reduce the leakage of the released contaminant from the target site to surrounding pristine regions. Containment wells facilitate the formation of hydraulic barriers. Hence, they control the movement of contaminants away from the site that is being remedied. However, these wells come into play, only when the pumping operation for cleaning up the site is active. After operation, they can be filled with soil to permit the natural ground water movement. They can also be used as monitoring wells.

  14. Ameliorative Effects of Neutral Electrolyzed Water on Growth Performance, Biochemical Constituents, and Histopathological Changes in Turkey Poults during Aflatoxicosis

    PubMed Central

    Gómez-Espinosa, Denise; Cervantes-Aguilar, Francisco Javier; Del Río-García, Juan Carlos; Villarreal-Barajas, Tania; Vázquez-Durán, Alma; Méndez-Albores, Abraham

    2017-01-01

    Different in vitro and in silico approaches from our research group have demonstrated that neutral electrolyzed water (NEW) can be used to detoxify aflatoxins. The objective of this investigation was to evaluate the ability of NEW to detoxify B-aflatoxins (AFB1 and AFB2) in contaminated maize and to confirm detoxification in an in vivo experimental model. Batches of aflatoxin-contaminated maize were detoxified with NEW and mixed in commercial feed. A total of 240 6-day-old female large white Nicholas-700 turkey poults were randomly divided into four treatments of six replicates each (10 turkeys per replicate), which were fed ad libitum for two weeks with the following dietary treatments: (1) control feed containing aflatoxin-free maize (CONTROL); (2) feed containing the aflatoxin-contaminated maize (AF); (3) feed containing the aflatoxin-contaminated maize detoxified with NEW (AF + NEW); and (4) control feed containing aflatoxin-free maize treated with NEW (NEW). Compared to the control groups, turkey poults of the AF group significantly reduced body weight gain and increased feed conversion ratio and mortality rate; whereas turkey poults of the AF + NEW group did not present significant differences on productive parameters. In addition, alterations in serum biochemical constituents, enzyme activities, relative organ weight, gross morphological changes and histopathological studies were significantly mitigated by the aflatoxin-detoxification procedure. From these results, it is concluded that the treatment of aflatoxin-contaminated maize with NEW provided reasonable protection against the effects caused by aflatoxins in young turkey poults. PMID:28335412

  15. Quality Assurance and Quality Control, Part 2.

    PubMed

    Akers, Michael J

    2015-01-01

    The tragedy surrounding the New England Compounding Center and contaminated steroid syringe preparations clearly points out what can happen if quality-assurance and quality-control procedures are not strictly practiced in the compounding of sterile preparations. This article is part 2 of a two-part article on requirements to comply with United States Pharmacopeia general chapters <797> and <1163> with respect to quality assurance of compounded sterile preparations. Part 1 covered documentation requirements, inspection procedures, compounding accuracy checks, and part of a discussion on bacterial endotoxin testing. Part 2 covers sterility testing, the completion from part 1 on bacterial endotoxin testing, a brief dicussion of United States Pharmacopeia <1163>, and advances in pharmaceutical quality systems.

  16. The design, effectiveness and acceptability of the arm sleeve for the prevention of body fluid contamination during obstetric procedures.

    PubMed

    Kabukoba, J J; Pearce, J M

    1993-08-01

    1. To design a device that would reduce contamination of staff during obstetric procedures. 2. To undertake clinical trials to assess the effectiveness and acceptability of such a device. A prospective study. The arm sleeve is made of a nonwoven material laminated on polyethylene film making it waterproof. It has an elastomeric cuff with adhesive that ensures a watertight seal between it and the glove. Delivery suite in a teaching hospital. Doctors and midwives were requested to wear the sleeve on top of the standard gown and gloves. Each user was assessed for blood contamination at the end of the procedure and a questionnaire detailing the extent of contamination and the views of the user was completed. Eighty questionnaires were completed. The contamination of arms and hands was 3.8% and 5%, respectively. Eighty-nine percent thought the sleeve had served its purpose and 76% said they would use it regularly. The sleeve is an effective protective device which complements the glove and gown. We recommend that it should be used during all obstetric procedures.

  17. Contamination of blood cultures during venepuncture: fact or myth?

    PubMed Central

    Shahar, E.; Wohl-Gottesman, B. S.; Shenkman, L.

    1990-01-01

    Contamination of blood cultures is believed to occur mainly during the venepuncture procedure. Consequently, meticulous preparation of the venepuncture site is widely recommended. To determine whether the contamination rate is indeed affected by the quality of the antiseptic procedure at the venepuncture site, 181 paired cultures were collected from 176 patients during a 6-month period after either strict antiseptic cleansing of skin with alcohol followed by povidone-iodine, or after brief disinfection with alcohol alone. The contamination rate was not influenced by the antiseptic procedure, and corresponded to the accepted percentage reported in most other studies. Eight false positive cultures (4.4%) were obtained after strict antisepsis of the skin and 6 (3.3%) after short simple cleansing with alcohol (P = 0.39). Our results suggest that contamination of blood cultures may not be related to the venepuncture procedure--regardless of the antiseptic technique used--but may be due to later stages of laboratory handling and processing of the specimens. Review of the literature has provided further indirect evidence to support this conclusion. PMID:2084653

  18. Contact angle determination procedure and detection of an invisible surface film

    NASA Technical Reports Server (NTRS)

    Meyer, G.; Grat, R.

    1990-01-01

    The contact angle value, i.e., the tangent angle of liquid resting on a planar solid surface, is a basic parameter which can be applied to a wide range of applications. The goal is to provide a basic understanding of the contact angle measurement technique and to present a simple illustration that can be applied as a quality control method; namely, detection of a surface contaminant which exists on a surface that appears clean to the unaided eye. The equipment and experimental procedures are detailed.

  19. [Cellular transplantation laboratory: a new field of action for nurses].

    PubMed

    Corradi, Maria Inês; da Silva, Sandra Honorato

    2008-01-01

    This article presents the experience of a nurse at a cellular transplantation laboratory. This laboratory goal is to isolate insulin producing cells for human transplantation. The nurse, as a member of an interdisciplinary team, took part in the planning of all work processes: working procedures and team training. The main activities under the nurse responsibilities include contamination control, on-the-job training and evaluation of the Quality of the procedures developed by the interdisciplinary team. Results have shown the effectiveness of the nurses' work in this new field.

  20. Infection control procedures used in conjunction with computed dental radiography.

    PubMed

    Hubar, J S; Gardiner, D M

    2000-10-01

    Infection control guidelines for dental radiography have been modified since 1986, when the American Dental Association and the Centers for Disease Control and Prevention supported the concept of "universal blood and body fluid precautions." With the introduction of computed digital radiography, hardware manufacturers recommend that alternative infection control techniques are necessary to prevent potential damage to the digital x-ray sensors placed inside the patient's mouth. Thirty first-year dental hygiene students were asked to insert and remove a Schick CDR number 2 size intraoral digital x-ray sensor into modified Rinn XCP bitewing bite blocks and a modified Rinn Snap-a-ray five times with each of the recommended infection control covers. Reduced rates of cross contamination are possible if the plastic barrier envelope has an additional latex finger cot stretched over it and the x-ray sensor. Sole usage of a latex finger cot will result in a reduced incidence of contamination, but still not to acceptable levels. However, a plastic barrier envelope placed over the x-ray sensor and over the modified XCP bite block together or a covered sensor in a Snap-a-ray under normal conditions does not result in a perforation and is least likely to result in cross contamination.

  1. Micro–mesoporous iron oxides with record efficiency for the decomposition of hydrogen peroxide: morphology driven catalysis for the degradation of organic contaminants

    EPA Science Inventory

    A template-free solid-state synthesis of a morphologically controlled and highly organized iron(III)oxide micro–mesoporous Fenton catalyst has been engineered through a simple two-step synthetic procedure. The 3D nanoassembly of hematite nanoparticles (5–7 nm) organized into a ro...

  2. Bond strength of self-etch adhesives after saliva contamination at different application steps.

    PubMed

    Cobanoglu, N; Unlu, N; Ozer, F F; Blatz, M B

    2013-01-01

    This study evaluated and compared the effect of saliva contamination and possible decontamination methods on bond strengths of two self-etching adhesive systems (Clearfil SE Bond [CSE], Optibond Solo Plus SE [OSE]). Flat occlusal dentin surfaces were created on 180 extracted human molar teeth. The two bonding systems and corresponding composite resins (Clearfil AP-X, Kerr Point 4) were bonded to the dentin under six surface conditions (n=15/group): group 1 (control): primer/bonding/composite; group 2: saliva/drying/primer/bonding/composite; group 3: primer/saliva/rinsing/drying/primer/bonding/composite; group 4: primer/saliva/rinsing/drying/bonding/composite; group 5: primer/bonding (cured)/saliva/rinsing/drying/primer/bonding/composite; group 6: primer/bonding (cured)/saliva/removing contaminated layer with a bur/rinsing/drying/primer/bonding/composite. Shear bond strength was tested after specimens were stored in distilled water at 37°C for 24 hours. One-way analysis of variance and Tukey post hoc tests were used for statistical analyses. For CSE, groups 2, 3, and 4 and for OSE, groups 6, 2, and 4 showed significantly lower bond strengths than the control group (p<0.05). CSE groups 5 and 6 and OSE groups 3 and 5 revealed bond strengths similar to the control. When saliva contamination occurred after light polymerization of the bonding agent, repeating the bonding procedure recovered the bonding capacity of both self-etch adhesives. However, saliva contamination before or after primer application negatively affected their bond strength.

  3. Late-in-life surgery associated with Creutzfeldt-Jakob disease: a methodological outline for evidence-based guidance

    PubMed Central

    2013-01-01

    Background There is increasing epidemiological evidence of etiological links between general surgery and sporadic Creutzfeldt-Jakob disease (sCJD) with long incubation periods. The purpose of this study was to identify specific surgical procedures potentially associated with sCJD to be targeted for preventive presurgical-intervention guidance. Results We propose a three-step clinical guidance outline where surgical procedures associated with sCJD clinical onset – potentially more contaminant - are taken into account. Data on hospital discharges and surgical procedures were obtained from Danish and Swedish national in-patient hospital registries for 167 sCJD cases, onset 1987–2003, and for 835 matched and 2,224 unmatched population controls. Surgery was allocated to different life-time periods as previously reported, and frequencies were compared using logistic regression analysis. In the year preceding clinical onset, persons with sCJD underwent a statistically significant higher number of minor surgical interventions (OR (95% CI): 17.50 (3.64-84.24)), transluminal endoscopies (OR: 2.73 (1.01–7.37)) and gastrointestinal operations (OR: 3.51 (1.21–10.19)) compared to matched controls. Surgical discharges clustered towards clinical onset. These differences increased during the clinical period, with statistically significant higher frequencies for both endoscopies and minor surgery (OR: 13.91 (5.87-32.95), and for main surgical procedures (OR: 2.10 (1.00-4.39)), particularly gastrointestinal surgery (OR: 6.00 (1.83-19.66)), and surgery contacting skeletal muscle. Comparisons with unmatched controls yielded similar results for neurosurgery in the clinical period (OR: 19.40 (2.22-168.34)). Conclusions These results suggest that some types of surgical procedures are associated with sCJD, after clinical onset or particularly just before onset. Selective planning of such surgery to minimize instrument/device contamination or quarantining might be feasible. Conditional to progress in sCJD etiological research, results are relevant for guidance development. PMID:23701872

  4. Viking planetary quarantine procedures and implementation

    NASA Technical Reports Server (NTRS)

    Howell, R.

    1974-01-01

    Some of the techniques and methodology that were used on Viking to implement planetary quarantine requirements are reported. Special attention was given to techniques and approaches used to implement sterilization of the Viking probe. Quarantine procedures for unmanned planetary missions and procedures for microbiological contamination of space hardware are included. A probability of contamination of the biological instruments onboard by terrestrial organisms was examined.

  5. Pseudocontamination of blood components with Burkholderia cepacia during quality controls.

    PubMed

    Ebner, W; Meyer, E; Schulz-Huotari, C; Scholz, R; Zilow, G; Daschner, F D

    2005-06-01

    We report on a pseudooutbreak of Burkholderia cepacia because of the use of a contaminated disinfectant during quality controls in a university blood bank. No septic reactions associated with transfusions had been reported in patients over the last 6 months. Analysis of the individual quality control procedures showed that a disinfectant based on a quaternary ammonium compound (QAC) had been used in order to disinfect the rubber stopper of the blood culture bottle. B. cepacia was found in a sample taken from this disinfectant, which was prepared with concentrate and tap water according to the manufacturer's instructions. The four isolates (one in disinfectant and three in blood components) were found to be identical in their biochemical reactions and resistance patterns. QAC-based disinfectants are not efficacious against a part of the spectrum of gram-negatives and are therefore inadequate. After introduction of an alcohol-based preparation, no more cases of B. cepacia contamination have been identified.

  6. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  7. INCIDENCE AND DETECTION OF PLEUROPNEUMONIA-LIKE ORGANISMS IN CELL CULTURES BY FLUORESCENT ANTIBODY AND CULTURAL PROCEDURES1

    PubMed Central

    Barile, Michael F.; Malizia, Walter F.; Riggs, Donald B.

    1962-01-01

    Barile, Michael F. (National Institutes of Health, Bethesda, Md.), Walter F. Malizia, and Donald B. Riggs. Incidence and detection of pleuropneumonia-like organisms in cell cultures by fluorescent antibody and cultural procedures. J. Bacteriol. 84:130–136. 1962—A total of 102 tissue-cell cultures from 17 separate laboratories was examined for pleuropneumonia-like organisms (PPLO) by the fluorescent antibody and cultural procedures. PPLO were isolated from 48 of the 49 tissue-cell cultures found positive for PPLO by the fluorescent antibody procedure, and results of the two procedures agreed in 101 of the 102 (99%) cases. PPLO were isolated from none of 10 primary-cell cultures prepared from six animal species and from 48 of 92 (52%) continuous-cell cultures prepared from eight animal species. Cells grown in media containing antibiotics were more frequently contaminated with PPLO (72%) than cells grown in antibiotic-free media (7%). Cultures (91%) from tissue-culture-producing laboratories and cultures (76%) used for propagation of microorganisms were contaminated with PPLO, although none used for tissue-culture metabolic studies was contaminated. In addition, our findings support the view that PPLO contamination of cell cultures is probably owing to bacterial contaminants which revert to L forms in the presence of antibiotics. Images PMID:13865001

  8. Laboratory procedure for estimating residue dynamics of xenobiotic contaminants in a freshwater food chain

    USGS Publications Warehouse

    Johnson, B. Thomas

    1980-01-01

    A laboratory method of measuring the accumulation, transfer, elimination, and degradation of xenobiotic contaminants is described for organisms in a freshwater food chain (microorganisms, filter-feeder, and fish). A flow-through diluter-system, 14C-labeled contaminants, gas and thin-layer chromatography, autoradiography, and liquid scintillation spectrometry are used in making residue determinations. Accumulation factors and various index values are developed for measuring and estimating potential accumulation of xenobiotic contaminants by aquatic organisms. The laboratory procedure is economical, simple, reproducible, and ecologically relevant.

  9. Sequestration of priority pollutant PAHs from sediment pore water employing semipermeable membrane devices.

    PubMed

    Williamson, Kelly S; Petty, Jimmie D; Huckins, James N; Lebo, Jon A; Kaiser, Edwin M

    2002-11-01

    Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri-Columbia, USA; Williamson et al., Chemosphere (This issue--PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.

  10. Sequestration of priority pollutant PAHs from sediment pore water employing semipermeable membrane devices

    USGS Publications Warehouse

    Williamson, K.S.; Petty, J.D.; Huckins, J.N.; Lebo, J.A.; Kaiser, E.M.

    2002-01-01

    Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri - Columbia, USA; Williamson et al., Chemosphere (This issue - PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.

  11. 9 CFR 354.243 - Operations and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 354.243 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Sanitary Conditions and Precautions Against Contamination of Products § 354.243 Operations and procedures... product against contamination by any foreign substance (including, but not being limited to, dust, dirt...

  12. Removing Contamination-Induced Reconstruction Artifacts from Cryo-electron Tomograms

    PubMed Central

    Fernandez, Jose-Jesus; Laugks, Ulrike; Schaffer, Miroslava; Bäuerlein, Felix J.B.; Khoshouei, Maryam; Baumeister, Wolfgang; Lucic, Vladan

    2016-01-01

    Imaging of fully hydrated, vitrified biological samples by electron tomography yields structural information about cellular protein complexes in situ. Here we present a computational procedure that removes artifacts of three-dimensional reconstruction caused by contamination present in samples during imaging by electron microscopy. Applying the procedure to phantom data and electron tomograms of cellular samples significantly improved the resolution and the interpretability of tomograms. Artifacts caused by surface contamination associated with thinning by focused ion beam, as well as those arising from gold fiducial markers and from common, lower contrast contamination, could be removed. Our procedure is widely applicable and is especially suited for applications that strive to reach a higher resolution and involve the use of recently developed, state-of-the-art instrumentation. PMID:26743046

  13. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus.

    PubMed

    Petti, S; Messano, G A

    2016-05-01

    Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (P<0.01). Log MRSA density reduction attributable to PCD was 1.16logcfu/cm(2), corresponding to 93% reduction of the baseline MRSA contamination. The disinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (<1cfu/cm(2)), but required 3h of exposure to photocatalysis. Thus, PCD could be considered for non-clinical surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Incidence of bacterial contamination and predisposing factors during bone and tendon allograft procurement.

    PubMed

    Terzaghi, Clara; Longo, Alessia; Legnani, Claudio; Bernasconi, Davide Paolo; Faré, Maristella

    2015-03-01

    The aim of this study was to analyze factors contributing to bacteriological contamination of bone and tendon allograft. Between 2008 and 2011, 2,778 bone and tendon allografts obtained from 196 organ and tissue donors or tissue donors only were retrospectively analysed. Several variables were taken into account: donor type (organ and tissue donors vs. tissue donor), cause of death, time interval between death and tissue procurement, duration of the procurement procedure, type of allografts, number of team members, number of trainees members, associated surgical procedures, positivity to haemoculture, type of procurement. The overall incidence of graft contamination was 23 %. The cause of death, the procurement time, the duration of procurement, the associated surgical procedures were not associated with increased risk of contamination. Significant effect on contamination incidence was observed for the number of staff members performing the procurement. In addition, our study substantiated significantly higher contamination rate among bone allografts than from tendon grafts. According to these observations, in order to minimize the contamination rate of procured musculoskeletal allografts, we recommend appropriate donor selection, use of standard sterile techniques, immediate packaging of each allograft to reduce graft exposure. Allograft procurement should be performed by a small surgical team.

  15. 21 CFR 120.6 - Sanitation standard operating procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... garments; (3) Prevention of cross contamination from insanitary objects to food, food packaging material... health conditions that could result in the microbiological contamination of food, food packaging... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sanitation standard operating procedures. 120.6...

  16. Reduced contamination of pig carcasses using an alternative pluck set removal procedure during slaughter.

    PubMed

    Biasino, W; De Zutter, L; Woollard, J; Mattheus, W; Bertrand, S; Uyttendaele, M; Van Damme, I

    2018-05-26

    This study compared the current pig slaughter procedure where the pluck set is completely removed with a procedure where the pluck set is partially removed, leaving the highly contaminated oral cavity, tonsils and tongue untouched. The effect on carcass contamination was investigated by enumerating hygiene indicator bacteria (total aerobic count, Enterobacteriaceae and E. coli) and cefotaxime-resistant E. coli (CREC) as well as assessing Salmonella and Yersinia enterocolitica presence on the sternum, elbow and throat of pig carcasses. Using the alternative pluck set removal, significantly lower mean numbers of hygiene indicator bacteria on throat samples and E. coli on elbow samples were found. Less pig carcasses were highly contaminated and a lower presence and level of CREC was observed. No difference in Salmonella or Yersinia enterocolitica presence was seen. The data in this study can help to assess the effect of this alternative procedure on the safety of pork and subsequently public health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Legionella in industrial cooling towers: monitoring and control strategies.

    PubMed

    Carducci, A; Verani, M; Battistini, R

    2010-01-01

    Legionella contamination of industrial cooling towers has been identified as the cause of sporadic cases and outbreaks of legionellosis among people living nearby. To evaluate and control Legionella contamination in industrial cooling tower water, microbiological monitoring was carried out to determine the effectiveness of the following different disinfection treatments: (i) continuous chlorine concentration of 0.01 ppm and monthly chlorine shock dosing (5 ppm) on a single cooling tower; (ii) continuous chlorine concentration of 0.4 ppm and monthly shock of biocide P3 FERROCID 8580 (BKG Water Solution) on seven towers. Legionella spp. and total bacterial count (TBC) were determined 3 days before and after each shock dose. Both strategies demonstrated that when chlorine was maintained at low levels, the Legionella count grew to levels above 10(4) CFU l(-1) while TBC still remained above 10(8 )CFU l(-1). Chlorine shock dosing was able to eliminate bacterial contamination, but only for 10-15 days. Biocide shock dosing was also insufficient to control the problem when the disinfectant concentration was administered at only one point in the plant and at the concentration of 30 ppm. On the other hand, when at a biocide concentration of 30 or 50 ppm was distributed throughout a number of points, depending on the plant hydrodynamics, Legionella counts decreased significantly and often remained below the warning limit. Moreover, the contamination of water entering the plant and the presence of sediment were also important factors for Legionella growth. For effective decontamination of outdoor industrial cooling towers, disinfectants should be distributed in a targeted way, taking into account the possible sources of contamination. The data of the research permitted to modify the procedure of disinfection for better reduce the water and aerosol contamination and consequently the exposure risk.

  18. Contamination in food from packaging material.

    PubMed

    Lau, O W; Wong, S K

    2000-06-16

    Packaging has become an indispensible element in the food manufacturing process, and different types of additives, such as antioxidants, stabilizers, lubricants, anti-static and anti-blocking agents, have also been developed to improve the performance of polymeric packaging materials. Recently the packaging has been found to represent a source of contamination itself through the migration of substances from the packaging into food. Various analytical methods have been developed to analyze the migrants in the foodstuff, and migration evaluation procedures based on theoretical prediction of migration from plastic food contact material were also introduced recently. In this paper, the regulatory control, analytical methodology, factors affecting the migration and migration evaluation are reviewed.

  19. Compliance with infection control practices in an university hospital dental clinic

    PubMed Central

    Mutters, Nico T.; Hägele, Ulrike; Hagenfeld, Daniel; Hellwig, Elmar; Frank, Uwe

    2014-01-01

    Aim: Compliance with infection control practices is the key to quality care and excellence in dentistry. Infection control remains one of the most cost-beneficial interventions available. However, implementing control procedures requires full compliance of the whole dental team. The aim of our study was to measure the compliance in daily clinical practice. Methods: The compliance with infection control practices in dentistry by dental health care personnel (DHCP) in a German university dental clinic was observed during clinical work. In addition, a survey was conducted to assess the individual knowledge about infection control procedures. Contamination of the workplace during invasive dental procedures was tested, as well. Results: A total of 58 invasive dental treatments implying close contacts between HCWs and patients were scrutinized. All HCWs (100%) wore gloves during dental work, but in some cases (female dentists: 14.3%; dental assistants: 28.6%) gloves were neither changed nor hands were disinfected between different activities or patient contacts (female dentists: 68.6%; male dentists: 60.9%; dental assistants: 93%). Only 31.4% of female and 39.1% of male dentists carried out adequate hygienic hand disinfection after removing gloves. Male dentists wore significantly more often (100%) protective eyewear compared to 77.1% of female dentists (p<0.05). In addition, most of female dentists (62.9%) and dental assistants (80.7%) wore jewelry during dental procedures. Conclusion: Despite the knowledge of distinct hygiene procedures only a small percentage of dental staff performs hygiene practices according to recommended guidelines. Strict audit is clearly needed in the dental setting to ensure compliance with infection control guidelines to prevent transmission of pathogens. Our results provide insights for the development of a targeted education and training strategy to enhance compliance of dental staff especially of dental assistants with infection control procedures. PMID:25285262

  20. Compliance with infection control practices in an university hospital dental clinic.

    PubMed

    Mutters, Nico T; Hägele, Ulrike; Hagenfeld, Daniel; Hellwig, Elmar; Frank, Uwe

    2014-01-01

    Compliance with infection control practices is the key to quality care and excellence in dentistry. Infection control remains one of the most cost-beneficial interventions available. However, implementing control procedures requires full compliance of the whole dental team. The aim of our study was to measure the compliance in daily clinical practice. The compliance with infection control practices in dentistry by dental health care personnel (DHCP) in a German university dental clinic was observed during clinical work. In addition, a survey was conducted to assess the individual knowledge about infection control procedures. Contamination of the workplace during invasive dental procedures was tested, as well. A total of 58 invasive dental treatments implying close contacts between HCWs and patients were scrutinized. All HCWs (100%) wore gloves during dental work, but in some cases (female dentists: 14.3%; dental assistants: 28.6%) gloves were neither changed nor hands were disinfected between different activities or patient contacts (female dentists: 68.6%; male dentists: 60.9%; dental assistants: 93%). Only 31.4% of female and 39.1% of male dentists carried out adequate hygienic hand disinfection after removing gloves. Male dentists wore significantly more often (100%) protective eyewear compared to 77.1% of female dentists (p<0.05). In addition, most of female dentists (62.9%) and dental assistants (80.7%) wore jewelry during dental procedures. Despite the knowledge of distinct hygiene procedures only a small percentage of dental staff performs hygiene practices according to recommended guidelines. Strict audit is clearly needed in the dental setting to ensure compliance with infection control guidelines to prevent transmission of pathogens. Our results provide insights for the development of a targeted education and training strategy to enhance compliance of dental staff especially of dental assistants with infection control procedures.

  1. Development of techniques for advanced optical contamination measurement with internal reflection spectroscopy, phase 1, volume 1

    NASA Technical Reports Server (NTRS)

    Hayes, J. D.

    1972-01-01

    The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.

  2. RCT: Module 2.11, Radiological Work Coverage, Course 8777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    2017-07-20

    Radiological work is usually approved and controlled by radiation protection personnel by using administrative and procedural controls, such as radiological work permits (RWPs). In addition, some jobs will require working in, or will have the potential for creating, very high radiation, contamination, or airborne radioactivity areas. Radiological control technicians (RCTs) providing job coverage have an integral role in controlling radiological hazards. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  3. Preharvest food safety.

    PubMed

    Childers, A B; Walsh, B

    1996-07-23

    Preharvest food safety is essential for the protection of our food supply. The production and transport of livestock and poultry play an integral part in the safety of these food products. The goals of this safety assurance include freedom from pathogenic microorganisms, disease, and parasites, and from potentially harmful residues and physical hazards. Its functions should be based on hazard analysis and critical control points from producer to slaughter plant with emphasis on prevention of identifiable hazards rather than on removal of contaminated products. The production goal is to minimize infection and insure freedom from potentially harmful residues and physical hazards. The marketing goal is control of exposure to pathogens and stress. Both groups should have functional hazard analysis and critical control points management programs which include personnel training and certification of producers. These programs must cover production procedures, chemical usage, feeding, treatment practices, drug usage, assembly and transportation, and animal identification. Plans must use risk assessment principles, and the procedures must be defined. Other elements would include preslaughter certification, environmental protection, control of chemical hazards, live-animal drug-testing procedures, and identification of physical hazards.

  4. The Effect of Airborne Contaminants on Fuel Cell Performance and Durability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St-Pierre, Jean; Pasaogullari, Ugur; Cheng, Tommy

    The impact of contaminants on fuel cell performance was examined to document air filter specifications (prevention) and devise recovery procedures (maintenance) that are effective at the system level. Eight previously undocumented airborne contaminants were selected for detailed studies and characterization data was used to identify operating conditions that intensifying contamination effects. The use of many and complementary electrochemical, chemical and physical characterization methods and the derivation of several mathematical models supported the formulation of contamination mechanisms and the development of recovery procedures. The complexity of these contamination mechanisms suggests a shift to prevention and generic maintenance measures. Only two ofmore » the selected contaminants led to cell voltage losses after injection was interrupted. Proposed recovery procedures for calcium ions, a component of road de-icers, dessicants, fertilizers and soil conditioners, were either ineffective or partly effective, whereas for bromomethane, a fumigant, the cell voltage was recovered to its initial value before contamination by manipulating and sequencing operating conditions. However, implementation for a fuel cell stack and system remains to be demonstrated. Contamination mechanisms also led to the identification of membrane durability stressors. All 8 selected contaminants promote the formation of hydrogen peroxide, a known agent that can produce radicals that attack the ionomer and membrane molecular structure whereas the dehydrating effect of calcium ions on the ionomer and membrane increases their brittleness and favors the creation of pinholes under mechanical stresses. Data related to acetylene, acetonitrile and calcium ions are emphasized in the report.« less

  5. A Permeable Active Amendment Concrete (PAAC) for Contaminant Remediation and Erosion Control

    DTIC Science & Technology

    2012-06-01

    124: 131 -143. SRNL-STI-2012-00356 70 Tessier, A., Campbell, P.G.C., and Bisson, M. 1979. Sequential extraction procedure for the speciation of...Bulk Density, Dry, (AI( C-D)]* p, pcf 134.85 Bulk Dens ity after Immersion, [BI(C-D)]* p, pcf 146.65 Bulk Density after Immersion & Boiling1 jCI (C

  6. Case Studies in Crewed Spacecraft Environmental Control and Life Support System Process Compatibility and Cabin Environmental Impact

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Contamination of a crewed spacecraft's cabin environment leading to environmental control and life support system (ECLSS) functional capability and operational margin degradation or loss can have an adverse effect on NASA's space exploration mission figures of merit-safety, mission success, effectiveness, and affordability. The role of evaluating the ECLSS's compatibility and cabin environmental impact as a key component of pass trace contaminant control is presented and the technical approach is described in the context of implementing NASA's safety and mission success objectives. Assessment examples are presented for a variety of chemicals used in vehicle systems and experiment hardware for the International Space Station program. The ECLSS compatibility and cabin environmental impact assessment approach, which can be applied to any crewed spacecraft development and operational effort, can provide guidance to crewed spacecraft system and payload developers relative to design criteria assigned ECLSS compatibility and cabin environmental impact ratings can be used by payload and system developers as criteria for ensuring adequate physical and operational containment. In additional to serving as an aid for guiding containment design, the assessments can guide flight rule and procedure development toward protecting the ECLSS as well as approaches for contamination event remediation.

  7. Heating and thermal control of brazing technique to break contamination path for potential Mars sample return

    NASA Astrophysics Data System (ADS)

    Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Campos, Sergio

    2017-04-01

    The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth's environment. In order to ensure the isolation of Mars microbes from Earth's Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-thechain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

  8. Overview of air biofiltration - basic technology, economics and integration with other control technologies for effective treatment of air toxics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Govind, R.; Bishop, D.F.

    1996-12-31

    This paper provides an overview of air biofiltration with experimental data on the performance of peat/compost, pelletized packed bed and structured media biofilters. It is shown that use of high surface area per unit volume structured media results in higher contaminant treatment rates per unit biofilter volume. Peat/compost biofilters exhibit lower removal efficiencies at high (> 100 ppmv) inlet contaminant concentrations and require control of media moisture content. Increase of temperature results in increasing biodegradation rates. It is shown that use of structured ceramic media allows effective control of biomass buildup by continuous removal of biomass from the biofilter mediamore » and that the biomass removal rate depends on nutrient flowrate. An experimental system is presented which enables biofilm kinetics to be determined and a simple biofilter model is developed in this paper. A group contribution approach has been developed to estimate biokinetic parameter which allows biofiltration effectiveness to be determined for a variety of volatile organic compounds (VOCs). Finally, a procedure is presented, illustrated by an example, which is used to develop an integrated process for effective treatment of air contaminants. 22 refs., 12 figs., 4 tabs.« less

  9. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    PubMed

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light-amber solutions. In addition, the reliability of the nutrient medium and the process was demonstrated by positive growth promotion tests with S. epidermidis. During automated preparation the recommended limits < 1 cfu per settle/contact plate set for cleanroom Grade A zones were not succeeded in the carousel and working area, but in the loading area of the robot. During manual preparation, the number of cfus detected on settle/contact plates inside the workbenches lay far below the limits. The number of cfus detected on fingertips succeeded several times the limit during manual preparation but not during automated preparation. There was no difference in the microbial contamination rate depending on the extent of cleaning and disinfection of the robot. Extensive media-fill tests simulating manual and automated preparation of ready-to-use cytotoxic injection solutions revealed the same level of sterility for both procedures. The results of supplemental environmental controls confirmed that the aseptic procedures are well controlled. As there was no difference in the microbial contamination rates of the media preparations depending on the extent of cleaning and disinfection of the robot, the results were used to adapt the respective standard operating procedures. © The Author(s) 2014.

  10. Microbial diversity in European and South American spacecraft assembly clean rooms

    NASA Astrophysics Data System (ADS)

    Moissl-Eichinger, Christine; Stieglmeier, Michaela; Schwendner, Petra

    Spacecraft assembly clean rooms are unique environments for microbes: Due to low nutri-ent levels, desiccated, clean conditions, constant control of humidity and temperature, these environments are quite inhospitable to microbial life and even considered "extreme". Many procedures keep the contamination as low as possible, but these conditions are also highly se-lective for indigenous microbial communities. For space missions under planetary protection requirements, it is crucial to control the contaminating bioburden as much as possible; but for the development of novel cleaning/sterilization methods it is also important to identify and characterize (understand) the present microbial community of spacecraft clean rooms. In prepa-ration for the recently approved ESA ExoMars mission, two European and one South American spacecraft assembly clean rooms were analyzed with respect to their microbial diversity, using standard procedures, new cultivation approaches and molecular methods, that should shed light onto the presence of planetary protection relevant microorganisms. For this study, the Her-schel Space Observatory (launched in May 2009) and its housing clean rooms in Friedrichshafen (Germany), at ESTEC (The Netherlands) and CSG, Kourou (French Guyana) were sampled during assembly, test and launch operations. Although Herschel does not demand planetary protection requirements, all clean rooms were in a fully operating state during sampling. This gave us the opportunity to sample the microbial diversity under strict particulate and molecular contamination-control. Samples were collected from spacecraft and selected clean room surface areas and were subjected to cultivation assays (32 different media), molecular studies (based on 16S rRNA gene sequence analysis) and quantitative PCR. The results from different strategies will be compared and critically discussed, showing the advantages and limits of the selected methodologies. This talk will sum up the lessons learned from this microbial diversity project.

  11. Control of Listeria species food safety at a poultry food production facility.

    PubMed

    Fox, Edward M; Wall, Patrick G; Fanning, Séamus

    2015-10-01

    Surveillance and control of food-borne human pathogens, such as Listeria monocytogenes, is a critical aspect of modern food safety programs at food production facilities. This study evaluated contamination patterns of Listeria species at a poultry food production facility, and evaluated the efficacy of procedures to control the contamination and transfer of the bacteria throughout the plant. The presence of Listeria species was studied along the production chain, including raw ingredients, food-contact, non-food-contact surfaces, and finished product. All isolates were sub-typed by pulsed-field gel electrophoresis (PFGE) to identify possible entry points for Listeria species into the production chain, as well as identifying possible transfer routes through the facility. The efficacy of selected in-house sanitizers against a sub-set of the isolates was evaluated. Of the 77 different PFGE-types identified, 10 were found among two or more of the five categories/areas (ingredients, food preparation, cooking and packing, bulk packing, and product), indicating potential transfer routes at the facility. One of the six sanitizers used was identified as unsuitable for control of Listeria species. Combining PFGE data, together with information on isolate location and timeframe, facilitated identification of a persistent Listeria species contamination that had colonized the facility, along with others that were transient. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Bacteriological evaluation of a new air turbine handpiece for preventing cross-contamination in dental procedures.

    PubMed

    Masuda, K; Ohta, M; Ohsuka, S; Matsuyama, M; Ashoori, M; Usami, T; Ito, M; Ueda, M; Kaneda, T

    1994-03-01

    An autoclavable air turbine handpiece, Air Flushing Clean System (AFCS) (Osada Electric Co., Ltd., Tokyo, Japan) was developed for use in dentistry with the objective of reducing cross-contamination. Its potential for bacterial contamination was investigated in vitro using two bacterial strains (Streptococcus mutants ATCC 25175 and Staphylococcus aureus FDA 209 P). In theory, this device should prevent cross-contamination of the internal water and air lines of the handpiece, by maintaining an internal positive pressure even after the turbine is stopped. In the present study, this AFCS device was found to reduce the bacterial contamination within the air turbine handpiece more effectively than the conventional handpiece used according to accepted protocol. The reduction of such contamination by the AFCS is in keeping with the recent objective of the American Dental Association to reduce cross-contamination during dental procedures.

  13. Toxic metal immobilization in contaminated sediment using bentonite- and kaolinite-supported nano zero-valent iron

    NASA Astrophysics Data System (ADS)

    Tomašević, D. D.; Kozma, G.; Kerkez, Dj. V.; Dalmacija, B. D.; Dalmacija, M. B.; Bečelić-Tomin, M. R.; Kukovecz, Á.; Kónya, Z.; Rončević, S.

    2014-08-01

    The objective of this study was to investigate the possibility of using supported nanoscale zero-valent iron with bentonite and kaolinite for immobilization of As, Pb and Zn in contaminated sediment from the Nadela river basin (Serbia). Assessment of the sediment quality based on the pseudo-total metal content (As, Pb and Zn) according to the corresponding Serbian standards shows its severe contamination, such that it requires disposal in special reservoirs and, if possible, remediation. A microwave-assisted sequential extraction procedure was employed to assess potential metal mobility and risk to the aquatic environment. According to these results, As showed lower risk to the environment than Pb and Zn, which both represent higher risk to the environment. The contaminated sediment, irrespective of the different speciation of the treated metals, was subjected to the same treatment. Semi-dynamic leaching test, based on leachability index and effective diffusion coefficients, was conducted for As-, Pb- and Zn-contaminated sediments in order to assess the long-term leaching behaviour. In order to simulate "worst case" leaching conditions, the test was modified using acetic and humic acid solution as leachants instead of deionized water. A diffusion-based model was used to elucidate the controlling leaching mechanisms; in the majority of samples, the controlling leaching mechanism appeared to be diffusion. Three different single-step leaching tests were applied to evaluate the extraction potential of examined metals. Generally, the test results indicated that the treated sediment is safe for disposal and could even be considered for "controlled utilization".

  14. Operating manual for the Bulk Shielding Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1983-04-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxillary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supercedes all previous operating manuals for the BSR.

  15. Operating manual for the Bulk Shielding Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-03-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxiliary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supersedes all previous operating manuals for the BSR.

  16. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  17. Optimisation of nasal swab analysis by liquid scintillation counting.

    PubMed

    Dai, Xiongxin; Liblong, Aaron; Kramer-Tremblay, Sheila; Priest, Nicholas; Li, Chunsheng

    2012-06-01

    When responding to an emergency radiological incident, rapid methods are needed to provide the physicians and radiation protection personnel with an early estimation of possible internal dose resulting from the inhalation of radionuclides. This information is needed so that appropriate medical treatment and radiological protection control procedures can be implemented. Nasal swab analysis, which employs swabs swiped inside a nostril followed by liquid scintillation counting of alpha and beta activity on the swab, could provide valuable information to quickly identify contamination of the affected population. In this study, various parameters (such as alpha/beta discrimination, swab materials, counting time and volume of scintillation cocktail etc) were evaluated in order to optimise the effectiveness of the nasal swab analysis method. An improved nasal swab procedure was developed by replacing cotton swabs with polyurethane-tipped swabs. Liquid scintillation counting was performed using a Hidex 300SL counter with alpha/beta pulse shape discrimination capability. Results show that the new method is more reliable than existing methods using cotton swabs and effectively meets the analysis requirements for screening personnel in an emergency situation. This swab analysis procedure is also applicable to wipe tests of surface contamination to minimise the source self-absorption effect on liquid scintillation counting.

  18. Effects of blood contamination on microtensile bond strength to dentin of three self-etch adhesives.

    PubMed

    Chang, Seok Woo; Cho, Byeong Hoon; Lim, Ran Yeob; Kyung, Seung Hyun; Park, Dong Sung; Oh, Tae Seok; Yoo, Hyun Mi

    2010-01-01

    This study evaluated the effects of blood contamination and decontamination methods during different steps of bonding procedures on the microtensile bond strength of two-step self-etch adhesives to dentin. Sixty extracted human molars were ground flat to expose occlusal dentin. The 60 molars were randomly assigned to three groups, each treated with a different two-step self-etch adhesive: Clearfil SE Bond, AdheSE and Tyrian SPE. In turn, these groups were subdivided into five subgroups (n = 20), each treated using different experimental conditions as follows: control group-no contamination; contamination group 1-CG1: primer application/ contamination/primer re-application; contamination group 2-CG2: primer application/contamination/wash/dry/primer re-application; contamination group 3-CG3: primer application/adhesive application/light curing/contamination/ adhesive re-application/light curing; contamina- tion group 4-CG4: primer application/adhesive application/light curing/contamination/wash/ dry/adhesive re-application/light curing. Composite buildup was performed using Z250. After 24 hours of storage in distilled water at 37 degrees C, the bonded specimens were trimmed to an hourglass shape and serially sectioned into slabs with 0.6 mm2 cross-sectional areas. Microtensile bond strengths (MTBS) were assessed for each specimen using a universal testing machine. The data were analyzed by two-way ANOVA followed by a post hoc LSD test. SEM evaluations of the fracture modes were also performed. The contaminated specimens showed lower bond strengths than specimens in the control group (p < 0.05), with the exception of CG1 in the Clearfil SE group and CG2 and CG3 in the Tyrian SPE group. Among the three self-etch adhesives, the Tyrian SPE group exhibited a significantly lower average MTBS compared to the Clearfil SE Bond and AdheSE (p < 0.05) groups. Based on the results of the current study, it was found that blood contamination reduced the MTBS of all three self-etch adhesives to dentin, and water-rinsing was unable to overcome the effects of blood contamination.

  19. Large-eddy simulation of human-induced contaminant transport in room compartments.

    PubMed

    Choi, J-I; Edwards, J R

    2012-02-01

    A large-eddy simulation is used to investigate contaminant transport owing to complex human and door motions and vent-system activity in room compartments where a contaminated and clean room are connected by a vestibule. Human and door motions are simulated with an immersed boundary procedure. We demonstrate the details of contaminant transport owing to human- and door-motion-induced wake development during a short-duration event involving the movement of a person (or persons) from a contaminated room, through a vestibule, into a clean room. Parametric studies that capture the effects of human walking pattern, door operation, over-pressure level, and vestibule size are systematically conducted. A faster walking speed results in less mass transport from the contaminated room into the clean room. The net effect of increasing the volume of the vestibule is to reduce the contaminant transport. The results show that swinging-door motion is the dominant transport mechanism and that human-induced wake motion enhances compartment-to-compartment transport. The effect of human activity on contaminant transport may be important in design and operation of clean or isolation rooms in chemical or pharmaceutical industries and intensive care units for airborne infectious disease control in a hospital. The present simulations demonstrate details of contaminant transport in such indoor environments during human motion events and show that simulation-based sensitivity analysis can be utilized for the diagnosis of contaminant infiltration and for better environmental protection. © 2011 John Wiley & Sons A/S.

  20. Traffic in the operating room: a review of factors influencing air flow and surgical wound contamination.

    PubMed

    Pokrywka, Marian; Byers, Karin

    2013-06-01

    Surgical wound contamination leading to surgical site infection can result from disruption of the intended airflow in the operating room (OR). When personnel enter and exit the OR, or create unnecessary movement and traffic during the procedure, the intended airflow in the vicinity of the open wound becomes disrupted and does not adequately remove airborne contaminants from the sterile field. An increase in the bacterial counts of airborne microorganisms is noted during increased activity levels within the OR. Researchers have studied OR traffic and door openings as a determinant of air contamination. During a surgical procedure the door to the operating room may be open as long as 20 minutes out of each surgical hour during critical procedures involving implants. Interventions into limiting excessive movement and traffic in the OR may lead to reductions in surgical site infections in select populations.

  1. Stability of safety glasses during sterilization and disinfection.

    PubMed

    Gleason, M J; Molinari, J A

    1987-07-01

    Awareness of the necessity for physical barriers as essential components of an infection control program for dental practice has led to increased use of gloves, masks, and protective eyewear. Because eyewear is not disposable, it could serve as a source of cross-contamination and should be disinfected between patients. This study investigates the optical stability of two types of safety glasses after various sterilization/disinfection procedures.

  2. Conceptual Processes for Linking Eutrophication and Network Models

    DTIC Science & Technology

    2006-08-01

    recommends a general procedure for future endeavors in this area. BACKGROUND: In recent years new ideas for nutrient management to control...network model. Coupling these two models will provide managers a new perspective on how to improve management strategies and help answer questions such...Dorothy H. Tillman, Dr. Carl F. Cerco, and Mr. Mark R. Noel of the Water Quality and Contaminant Modeling Branch, Enviromental Laboratory (EL

  3. Outbreak of Salmonella infantis infection in a large animal veterinary teaching hospital.

    PubMed

    Tillotson, K; Savage, C J; Salman, M D; Gentry-Weeks, C R; Rice, D; Fedorka-Cray, P J; Hendrickson, D A; Jones, R L; Nelson, W; Traub-Dargatz, J L

    1997-12-15

    During the past 11 years, there have been numerous reports of outbreaks of salmonellosis involving horses in veterinary teaching hospitals. Some of these outbreaks have been associated with Salmonella serotypes not commonly associated with infection of horses. Salmonella infantis is among the more common Salmonella serotypes isolated from human beings, and is an important pathogen in the broiler chicken industry. However, it was not commonly isolated from horses or cattle on a national basis between 1993 and 1995. In this report, we describe an outbreak of S infantis infection among large animals, primarily horses, in a veterinary teaching hospital and the control measures that were implemented. Factors that appeared to be key in control of this outbreak in this hospital included providing biosecurity training sessions for hospital personnel, adopting a standard operating procedure manual for biosecurity procedures, installing additional handwashing sinks throughout the facility, painting the interior of the facility with a nontoxic readily cleanable paint, replacing the dirt flooring in 4 stalls with concrete flooring, and removing noncleanable surfaces such as rubber stall mats, wooden hay storage bins, and open grain bins. Our experience with this outbreak suggests that although it is virtually impossible to eliminate Salmonella organisms from the environment, minimizing contamination is possible. Prevention of nosocomial infection must be approached in a multifaceted manner and care must be taken to search out covert sources of contamination, especially if standard intervention procedures do not prevent spread of the disease.

  4. Microbial contamination of nonsterile pharmaceuticals in public hospital settings

    PubMed Central

    Mugoyela, Veronica; Mwambete, Kennedy D

    2010-01-01

    Purpose Contamination of pharmaceuticals with microorganisms irrespective whether they are harmful or nonpathogenic can bring about changes in physicochemical characteristics of the medicines. Although sterility is not a requirement in official compendia for nonsterile pharmaceuticals, bioburdens need to be within acceptable limits. Therefore, this study investigated microbial contamination of 10 nonsterile pharmaceuticals frequently delivered to outpatients by identifying and quantifying microbial contaminants and susceptibility pattern testing on the microbes isolated. Methods The study was carried out at Amana Municipal Hospital in Dar es Salaam, Tanzania. The protocol for the study involved structured selection of representative tablets, syrups, and capsules from the hospital’s outpatient pharmacy. Constitutive microorganisms were elaborated and enumerated using standard microbiologic procedures. Results Results showed that 50% of all tested products were heavily contaminated, and the predominant contaminants comprised Klebsiella, Bacillus, and Candida species. Furthermore, the results showed that the isolated Bacillus and Klebsiella species were resistant to Augmentin ® and cloxacillin. The differences in means for cfu/mL and zones of inhibition among the microorganisms isolated were considered significant at P < 0.05. Conclusion The nonsterile pharmaceuticals were presumably microbiologically contaminated due to poor handling during dispensing, repackaging, and/or nonadherence to good manufacturing practice. Therefore, training and educating the dispensers, as well as patients, on the proper handling and use of medicines cannot be overemphasized, because these are key aspects in controlling cross-contamination of medicines. PMID:20957135

  5. Mars 96 small station biological decontamination

    NASA Astrophysics Data System (ADS)

    Debus, A.; Runavot, J.; Rogovski, G.; Bogomolov, V.; Khamidullina, N.; Darbord, J. C.; Plombin, B. J.; Trofimov, V.; Ivanov, M.

    In the context of extraterrestrial exploration missions and since the beginning of solar system exploration, it is required, according to the article IX of the Outer Space Treaty (London/Washington January 27, 1967) to preserve planets and the Earth from cross contamination. Consequently, COSPAR (Committee of Space Research) has established some planetary protection recommendations in order to protect the environments of other worlds from biological contamination by terrestrial microorganisms, to protect exobiological science for searching for life on planets, and to protect the Earth's environment from back contamination. For the upcoming Mars exploration missions, and after updating the planetary protection recommendations, a biological decontamination program has been designed for Mars 96 landers. After sterilization or biocleaning of equipment and instruments, these are integrated into a cleanroom and kept in sterile conditions with recontamination control in order to satisfy the surface contamination requirements. The Mars 96 orbiter does not need any implementation of sterilization procedures because the probability of spacecraft crash does not exceed 10^-5 and because it's orbit is in accordance with quarantine requirements (orbit lifetime with 0.9999 confidence for the first 20 years and 0.95 confidence during the next 20 years). For the Mars 96 small stations, different methods have been used and especially for the French and Finnish payload, a complete description of hydrogen peroxide gas plasma sterilization will be given, including bioburden assessments and sterility level determination. Probe integration implementation and procedures are described in the second part of this paper.

  6. 9 CFR 113.30 - Detection of Salmonella contamination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...

  7. 9 CFR 113.30 - Detection of Salmonella contamination.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...

  8. Mercury contaminated sediment sites-an evaluation of remedial options.

    PubMed

    Randall, Paul M; Chattopadhyay, Sandip

    2013-08-01

    Mercury (Hg) is a naturally-occurring element that is ubiquitous in the aquatic environment. Though efforts have been made in recent years to decrease Hg emissions, historically-emitted Hg can be retained in the sediments of aquatic bodies where they may be slowly converted to methylmercury (MeHg). Consequently, Hg in historically-contaminated sediments can result in high levels of significant exposure for aquatic species, wildlife and human populations consuming fish. Even if source control of contaminated wastewater is achievable, it may take a very long time, perhaps decades, for Hg-contaminated aquatic systems to reach relatively safe Hg levels in both water and surface sediment naturally. It may take even longer if Hg is present at higher concentration levels in deep sediment. Hg contaminated sediment results from previous releases or ongoing contributions from sources that are difficult to identify. Due to human activities or physical, chemical, or biological processes (e.g. hydrodynamic flows, bioturbation, molecular diffusion, and chemical transformation), the buried Hg can be remobilized into the overlying water. Hg speciation in the water column and sediments critically affect the reactivity (i.e. conversion of inorganic Hg(II) to MeHg), transport, and its exposure to living organisms. Also, geochemical conditions affect the activity of methylating bacteria and its availability for methylation. This review paper discusses remedial considerations (e.g. key chemical factors in fate and transport of Hg, source characterization and control, environmental management procedures, remediation options, modeling tools) and includes practical case studies for cleaning up Hg-contaminated sediment sites. Published by Elsevier Inc.

  9. Sequence analysis of the canine mitochondrial DNA control region from shed hair samples in criminal investigations.

    PubMed

    Berger, C; Berger, B; Parson, W

    2012-01-01

    In recent years, evidence from domestic dogs has increasingly been analyzed by forensic DNA testing. Especially, canine hairs have proved most suitable and practical due to the high rate of hair transfer occurring between dogs and humans. Starting with the description of a contamination-free sample handling procedure, we give a detailed workflow for sequencing hypervariable segments (HVS) of the mtDNA control region from canine evidence. After the hair material is lysed and the DNA extracted by Phenol/Chloroform, the amplification and sequencing strategy comprises the HVS I and II of the canine control region and is optimized for DNA of medium-to-low quality and quantity. The sequencing procedure is based on the Sanger Big-dye deoxy-terminator method and the separation of the sequencing reaction products is performed on a conventional multicolor fluorescence detection capillary electrophoresis platform. Finally, software-aided base calling and sequence interpretation are addressed exemplarily.

  10. Organic Contamination Baseline Study in NASA Johnson Space Center Astromaterials Curation Laboratories

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Allen, Carlton C.; Allton, Judith H.

    2014-01-01

    Future robotic and human spaceflight missions to the Moon, Mars, asteroids, and comets will require curating astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. 21st century sample return missions will focus on strict protocols for reducing organic contamination that have not been seen since the Apollo manned lunar landing program. To properly curate these materials, the Astromaterials Acquisition and Curation Office under the Astromaterial Research and Exploration Science Directorate at NASA Johnson Space Center houses and protects all extraterrestrial materials brought back to Earth that are controlled by the United States government. During fiscal year 2012, we conducted a year-long project to compile historical documentation and laboratory tests involving organic investigations at these facilities. In addition, we developed a plan to determine the current state of organic cleanliness in curation laboratories housing astromaterials. This was accomplished by focusing on current procedures and protocols for cleaning, sample handling, and storage. While the intention of this report is to give a comprehensive overview of the current state of organic cleanliness in JSC curation laboratories, it also provides a baseline for determining whether our cleaning procedures and sample handling protocols need to be adapted and/or augmented to meet the new requirements for future human spaceflight and robotic sample return missions.

  11. First environmental data from the EUV engineering test stand

    NASA Astrophysics Data System (ADS)

    Klebanoff, Leonard E.; Malinowski, Michael E.; Grunow, Philip A.; Clift, W. Miles; Steinhaus, Chip; Leung, Alvin H.; Haney, Steven J.

    2001-08-01

    The first environmental data from the Engineering Test Stand (ETS) has been collected. Excellent control of high-mass hydrocarbons has been observed. This control is a result of extensive outgas testing of components and materials, vacuum compatible design of the ETS, careful cleaning of parts and pre-baking of cables and sub assemblies where possible, and clean assembly procedures. As a result of the hydrocarbon control, the residual ETS vacuum environment is rich in water vapor. Analysis of witness plate data indicates that the ETS environment does not pose a contamination risk to the optics in the absence of EUV irradiation. However, with EUV exposure, the water rich environment can lead to EUV- induced water oxidation of the Si-terminated Mo/Si optics. Added ethanol can prevent optic oxidation, allowing carbon growth via EUV cracking of low-level residual hydrocarbons to occur. The EUV environmental issues are understood, mitigation approaches have been validated, and EUV optic contamination appears to be manageable.

  12. Influence of a Brazilian sewage outfall on the toxicity and contamination of adjacent sediments

    USGS Publications Warehouse

    Abessa, D.M.S.; Carr, R.S.; Rachid, B.R.F.; Sousa, E.C.P.M.; Hortelani, M.A.; Sarkis, J.E.

    2005-01-01

    The submarine sewage outfall of Santos (SSOS) is situated in the Santos Bay (São Paulo, Brazil) and is potentially a significant source of contaminants to the adjacent marine ecosystem. The present study aimed to assess the influence of SSOS on the sediment toxicity and contamination at Santos Bay. At the disposal site, sediments tended to be finer, organically richer and exhibited higher levels of surfactants and metals, sometimes exceeding the “Threshold Effect Level” values. The SSOS influence was more evident toward the East, where the sediments exhibited higher levels of TOC, total S and metals during the summer 2000 sampling campaign. Sediment toxicity to amphipods was consistently detected in four of the five stations studied. Amphipod survival tended to correlate negatively to Hg, total N and % mud. This work provides evidence that the SSOS discharge affects the quality of sediments from Santos Bay, and that control procedures are warranted.

  13. Evaluation of the effectiveness of sepiolite, bentonite, and phosphate amendments on the stabilization remediation of cadmium-contaminated soils.

    PubMed

    Sun, Yuebing; Sun, Guohong; Xu, Yingming; Liu, Weitao; Liang, Xuefeng; Wang, Lin

    2016-01-15

    A pot trial was conducted to assess the effectiveness of sepiolite, bentonite, and phosphate on the immobilization remediation of cadmium (Cd)-contaminated soils using a set of variables, namely, physiological traits, sequential extraction procedure, plant growth and Cd concentration, and soil enzymatic activities and microbial population. Results showed that superoxide dismutase and peroxidase activities in the leaves of Oryza sativa L. and catalase activities in soils were stimulated after applying the amendments. However, soluble protein contents in leaves and urease and invertase activities in soils were reduced from 7.1% to 31.7%, 1.0%-23.3%, and 21.1%-62.5%, respectively, compared with the control. Results of the sequence extraction procedures revealed that the exchangeable fraction of Cd in soils was mostly converted into carbonated-associated forms. The water soluble plus exchangeable fraction (SE) of Cd in soil decreased when treated with single and compound materials of sepiolite, bentonite and phosphate, which resulted in 13.2%-69.2% reduction compared with that of CK (control test). The amendments led to decreased Cd concentrations in roots, stems, leaves, brown rice, and rice hull by 16.2%-54.5%, 16.6%-42.8%, 19.6%-59.6%, 5.0%-68.2%, and 6.2%-20.4%, respectively. Higher bacterial and actinomycete amount indicated that remediation measures improved soil environmental quality. Composite amendments could be more efficiently used for the stabilization remediation of Cd contaminated soils with low Cd uptake and translocation in the plants and available contents of Cd in soil. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. In vitro adhesion of Acanthamoeba castellanii to soft contact lenses depends on water content and disinfection procedure.

    PubMed

    Reverey, Julia F; Fromme, Roland; Leippe, Matthias; Selhuber-Unkel, Christine

    2014-08-01

    To compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures. Different unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated. We found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments. With this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  15. Safety concerns for first entry operations of orbiting spacecraft

    NASA Technical Reports Server (NTRS)

    Wilson, Steven H.; Limero, Thomas F.; James, John T.

    1994-01-01

    The Space Station Freedom crew will face operational problems unique to the spacecraft environment due to the absence of convection currents and the confined atmosphere within the habitable modules. Airborne contaminants from the materials offgassing or contingency incidents like thermodegradation may accumulate until they reach hazardous concentrations. Flow modeling and experiences from previous space flight missions confirm that caution must be exercised during first-entry operations. A review of the first-entry procedures performed during the Skylab Program will be presented to highlight the necessity for carefully planned operations. Many of the environmental conditions that can be expected on the Space Station are analogous to those which exist in confined storage or work spaces in the industrial setting. Experience with closed-loop environmental operations (e.g., atmospheric control of submarines) have also demonstrated that the buildup of trace contaminant gases could result in conditions that lead to mission termination or loss of crew. Consequently, some first-entry issues for the Station can be addressed by comparing them to familiar techniques developed on Earth. The instruments of the Environmental Health System (EHS) will provide the necessary monitoring capability to protect crew health and safety during the planned first-entry procedures of the MTC phase of the SSF Program. The authors of this paper will describe those procedures and will cite an example of the consequences when proper first-entry procedures are not followed.

  16. FACILITATED TRANSPORT OF INORGANIC CONTAMINANTS IN GROUNDWATER: PART II. COLLOIDAL TRANSPORT

    EPA Science Inventory

    This project consisted of both field and laboratory components. Field studies evaluated routine sampling procedures for determination of aqueous inorganicgeochemistry and assessment of contaminant transport by colloidal mobility. Research at three different metal-contaminated sit...

  17. Microbial Groundwater Sampling Protocol for Fecal-Rich Environments

    PubMed Central

    Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William

    2014-01-01

    Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186

  18. A GIS-based human health risk assessment for urban green space planning--an example from Grugliasco (Italy).

    PubMed

    Poggio, Laura; Vrscaj, Borut

    2009-11-15

    The need to develop approaches for risk-based management of soil contamination, as well as the integration of the assessment of the human health risk (HHR) due to the soil contamination in the urban planning procedures has been the subject of recent attention of scientific literature and policy makers. The spatial analysis of environmental data offers multiple advantages for studying soil contamination and HHR assessment, facilitating the decision making process. The aim of this study was to explore the possibilities and benefits of spatial implementation of a quantitative HHR assessment methodology for a planning case in a typical urban environment where the soil is contaminated. The study area is located in the city of Grugliasco a part of the Turin (Italy) metropolitan area. The soils data were derived from a site specific soil survey and the land-use data from secondary sources. In the first step the soil contamination data were geo-statistically analysed and a spatial soil contamination data risk modelling procedure designed. In order to spatially assess the HHR computer routines were developed using GIS raster tools. The risk was evaluated for several different land uses for the planned naturalistic park area. The HHR assessment indicated that the contamination of soils with heavy metals in the area is not sufficient to induce considerable health problems due to typical human behaviour within the variety of urban land uses. An exception is the possibility of direct ingestion of contaminated soil which commonly occurs in playgrounds. The HHR evaluation in a planning case in the Grugliasco Municipality confirms the suitability of the selected planning option. The construction of the naturalistic park presents one solution for reducing the impacts of soil contamination on the health of citizens. The spatial HHR evaluation using GIS techniques is a diagnostic procedure for assessing the impacts of urban soil contamination, with which one can verify planning options, and provides an important step in the integration of human health protection within urban planning procedures.

  19. Single aflatoxin contaminated corn kernel analysis with fluorescence hyperspectral image

    NASA Astrophysics Data System (ADS)

    Yao, Haibo; Hruska, Zuzana; Kincaid, Russell; Ononye, Ambrose; Brown, Robert L.; Cleveland, Thomas E.

    2010-04-01

    Aflatoxins are toxic secondary metabolites of the fungi Aspergillus flavus and Aspergillus parasiticus, among others. Aflatoxin contaminated corn is toxic to domestic animals when ingested in feed and is a known carcinogen associated with liver and lung cancer in humans. Consequently, aflatoxin levels in food and feed are regulated by the Food and Drug Administration (FDA) in the US, allowing 20 ppb (parts per billion) limits in food and 100 ppb in feed for interstate commerce. Currently, aflatoxin detection and quantification methods are based on analytical tests including thin-layer chromatography (TCL) and high performance liquid chromatography (HPLC). These analytical tests require the destruction of samples, and are costly and time consuming. Thus, the ability to detect aflatoxin in a rapid, nondestructive way is crucial to the grain industry, particularly to corn industry. Hyperspectral imaging technology offers a non-invasive approach toward screening for food safety inspection and quality control based on its spectral signature. The focus of this paper is to classify aflatoxin contaminated single corn kernels using fluorescence hyperspectral imagery. Field inoculated corn kernels were used in the study. Contaminated and control kernels under long wavelength ultraviolet excitation were imaged using a visible near-infrared (VNIR) hyperspectral camera. The imaged kernels were chemically analyzed to provide reference information for image analysis. This paper describes a procedure to process corn kernels located in different images for statistical training and classification. Two classification algorithms, Maximum Likelihood and Binary Encoding, were used to classify each corn kernel into "control" or "contaminated" through pixel classification. The Binary Encoding approach had a slightly better performance with accuracy equals to 87% or 88% when 20 ppb or 100 ppb was used as classification threshold, respectively.

  20. Glove perforation time and frequency in total hip arthroplasty procedures.

    PubMed

    Kaya, Ibrahim; Uğraş, Akin; Sungur, Ibrahim; Yilmaz, Murat; Korkmaz, Musa; Cetinus, Ercan

    2012-01-01

    The aim of the present study was to investigate glove perforation rate and time and evaluate the factors affecting glove perforation in total hip arthroplasty (THA). Nine hundred seventy-nine gloves used in 57 THA procedures were assessed according to the perforation. Forty-four (77.2%) procedures were primary THA and 13 (22.8%) were revision THA. Gloves were changed when perforated, become dirty with blood or blood products, and before bone cementing. All gloves were filled with water at the end of the operation and controlled for perforation. Two hundred and one surgical gloves used during scrubbing and removed after draping the patient were examined as the control group. The location (which finger), number and time of the perforation, surgery type and duration, and distribution of the perforation location according to the surgical team were assessed. Patients' mean age was 62.9 ± 14.6 (range: 33 to 97) years and the mean surgery duration was 162.9 ± 32.0 minutes. Thirty-two glove perforations were noted in 19 of the operations. Of these perforations, 28 belonged to the surgeons and first assistants. There was no significant difference between the dominant or non-dominant hand according to the location of perforations. Perforations in the first and second fingers of the gloves accounted for 81.3% of all perforations. There was no significant difference in terms of number of gloves used, perforation numbers and operation duration between the primary and revision THA procedures. Two perforated gloves (0.99%) were found in the control group and the difference between the number of perforations in the control and study groups was significant (p=0.048). We recommend the use of two pairs of gloves to avoid the risk of contamination and protect the surgical team from infectious disease in major surgeries like THA. Surgical gloves should be changed when they are excessively contaminated with surgical fluids and the surgeon and first assistant should also change their outer gloves at an average of every 90 minutes.

  1. Analysis of trace contamination of phthalate esters in ultrapure water using a modified solid-phase extraction procedure and automated thermal desorption-gas chromatography/mass spectrometry.

    PubMed

    Liu, Hsu-Chuan; Den, Walter; Chan, Shu-Fei; Kin, Kuan Tzu

    2008-04-25

    The present study was aimed to develop a procedure modified from the conventional solid-phase extraction (SPE) method for the analysis of trace concentration of phthalate esters in industrial ultrapure water (UPW). The proposed procedure allows UPW sample to be drawn through a sampling tube containing hydrophobic sorbent (Tenax TA) to concentrate the aqueous phthalate esters. The solid trap was then demoisturized by two-stage gas drying before subjecting to thermal desorption and analysis by gas chromatography-mass spectrometry. This process removes the solvent extraction procedure necessary for the conventional SPE method, and permits automation of the analytical procedure for high-volume analyses. Several important parameters, including desorption temperature and duration, packing quantity and demoisturizing procedure, were optimized in this study based on the analytical sensitivity for a standard mixture containing five different phthalate esters. The method detection limits for the five phthalate esters were between 36 ng l(-1) and 95 ng l(-1) and recovery rates between 15% and 101%. Dioctyl phthalate (DOP) was not recovered adequately because the compound was both poorly adsorbed and desorbed on and off Tenax TA sorbents. Furthermore, analyses of material leaching from poly(vinyl chloride) (PVC) tubes as well as the actual water samples showed that di-n-butyl phthalate (DBP) and di(2-ethylhexyl) phthalate (DEHP) were the common contaminants detected from PVC contaminated UPW and the actual UPW, as well as in tap water. The reduction of DEHP in the production processes of actual UPW was clearly observed, however a DEHP concentration of 0.20 microg l(-1) at the point of use was still being quantified, suggesting that the contamination of phthalate esters could present a barrier to the future cleanliness requirement of UPW. The work demonstrated that the proposed modified SPE procedure provided an effective method for rapid analysis and contamination identification in UPW production lines.

  2. 21 CFR 1270.31 - Written procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...

  3. 21 CFR 1270.31 - Written procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...

  4. 21 CFR 1270.31 - Written procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...

  5. 21 CFR 1270.31 - Written procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... procedures prepared and followed for all significant steps in the infectious disease testing process under... procedures prepared, validated, and followed for prevention of infectious disease contamination or cross...

  6. Agricultural areas in potentially contaminated sites: characterization, risk, management.

    PubMed

    Vanni, Fabiana; Scaini, Federica; Beccaloni, Eleonora

    2016-01-01

    In Italy, the current legislation for contaminants in soils provides two land uses: residential/public or private gardens and commercial/industrial; there are not specific reference values for agricultural soils, even if a special decree has been developed and is currently going through the legislative approval process. The topic of agricultural areas is relevant, also in consideration of their presence near potentially contaminated sites. Aim and results. In this paper, contamination sources and transport modes of contaminants from sources to the target in agricultural areas are examined and a suitable "conceptual model" to define appropriate characterization methods and risk assessment procedures is proposed. These procedures have already been used by the National Institute of Health in various Italian areas characterized by different agricultural settings. Finally, specific remediation techniques are suggested to preserve soil resources and, if possible, its particular land use.

  7. The ecological impact of land restoration and cleanup. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-08-01

    The report is concerned with the ecological impacts of specific cleanup treatment on the land where they were carried out. The cleanup procedures given apply equally to chemical or radioactive materials. Guidance is provided for cleanup procedures likely to be suggested by government, industry, or environmental groups. The basic types of cleanup procedures for removing or deactiving spilled contamination involve moving people and animals from the affected area, scraping and grading the contaminated soil into windrows, plowing the contamination under, or digging up the contamination and hauling it away. The report describes and evaluates the various land-type cleanup effects inmore » terms of impact of the techniques on the environment. Part I defines several natural ecosystems and some of their natural derivations. Part II presents managed ecosystems which are imposed on natural ecosystems and are no longer bound by the initial native ecosystem balances. Part III deals with avion and mammilian wild life displaced by cleanup.« less

  8. Risk of contamination of nasal sprays in otolaryngologic practice

    PubMed Central

    Aydin, Erdinc; Hizal, Evren; Akkuzu, Babur; Azap, Ozlem

    2007-01-01

    Background Reusable nasal-spray devices are frequently used in otolaryngologic examinations, and there is an increasing concern about the risk of cross-contamination from these devices. The aim of our study was to determine, by means of microbiologic analysis, the safety of a positive-displacement or pump-type atomizer after multiple uses. Methods A reusable nasal spray bottle, pump, and tips were used in the nasal physical examination of 282 patients admitted to a tertiary otolaryngology clinic. The effectiveness of 2 different methods of prophylaxis against microbiologic contamination (the use of protective punched caps or rinsing the bottle tip with alcohol) was compared with that of a control procedure. Results Although there was no statistically significant difference in positive culture rates among the types of nasal spray bottles tested, methicillin-resistant coagulase-negative staphylococci were isolated in 4 of 198 cultures. Conclusion Given these findings, we concluded that additional precautions (such as the use of an autoclave between sprays, disposable tips, or disposable devices) are warranted to avoid interpatient cross-contamination from a reusable nasal spray device. PMID:17352835

  9. Microbial contamination of contact lenses after scaling and root planing using ultrasonic scalers with and without protective eyewear: A clinical and microbiological study.

    PubMed

    Afzha, Rooh; Chatterjee, Anirban; Subbaiah, Shobha Krishna; Pradeep, Avani Rangaraju

    2016-01-01

    Ultrasonic scaler is a preferential treatment modality among the clinicians. However, the aerosol/splatter generated is a concern for patients and practitioners. Therefore, the purpose of this study was to evaluate contamination of contact lenses of the dentist after scaling and root planing using ultrasonic scalers with and without protective eyewear. Thirty patients were randomly selected for scaling and root planing and divided into 2 groups of 15 each. Group A - dentist wearing contact lenses and protective eyewear. Group B - dentist wearing only contact lenses. After scaling and root planing using ultrasonic scalers, the lenses were subjected to culture and 16S rRNA (16S ribosomal RNA) gene sequencing. In Group A - 15 out of thirty samples were contaminated, in Group B - all the thirty samples were contaminated. Most of the samples showed Gram-positive bacteria and 5 samples were contaminated with fungi. 16S rRNA gene sequencing of forty contaminated samples showed that 31 were contaminated with Streptococcus mutans and 9 with Staphylococcus aureus. Keeping in mind the limitation of the study for the absence of negative control, we would like to conclude that dental practitioners should better avoid contact lenses in a dental setup because of the risk of contamination of the contact lenses from the various dental procedures which can produce aerosol/splatter and if worn, it is recommended to wear protective eyewear.

  10. Microbial contamination of contact lenses after scaling and root planing using ultrasonic scalers with and without protective eyewear: A clinical and microbiological study

    PubMed Central

    Afzha, Rooh; Chatterjee, Anirban; Subbaiah, Shobha Krishna; Pradeep, Avani Rangaraju

    2016-01-01

    Background: Ultrasonic scaler is a preferential treatment modality among the clinicians. However, the aerosol/splatter generated is a concern for patients and practitioners. Therefore, the purpose of this study was to evaluate contamination of contact lenses of the dentist after scaling and root planing using ultrasonic scalers with and without protective eyewear. Materials and Methods: Thirty patients were randomly selected for scaling and root planing and divided into 2 groups of 15 each. Group A – dentist wearing contact lenses and protective eyewear. Group B - dentist wearing only contact lenses. After scaling and root planing using ultrasonic scalers, the lenses were subjected to culture and 16S rRNA (16S ribosomal RNA) gene sequencing. Results: In Group A – 15 out of thirty samples were contaminated, in Group B – all the thirty samples were contaminated. Most of the samples showed Gram-positive bacteria and 5 samples were contaminated with fungi. 16S rRNA gene sequencing of forty contaminated samples showed that 31 were contaminated with Streptococcus mutans and 9 with Staphylococcus aureus. Conclusion: Keeping in mind the limitation of the study for the absence of negative control, we would like to conclude that dental practitioners should better avoid contact lenses in a dental setup because of the risk of contamination of the contact lenses from the various dental procedures which can produce aerosol/splatter and if worn, it is recommended to wear protective eyewear. PMID:27563200

  11. Human health risk assessment: models for predicting the effective exposure duration of on-site receptors exposed to contaminated groundwater.

    PubMed

    Baciocchi, Renato; Berardi, Simona; Verginelli, Iason

    2010-09-15

    Clean-up of contaminated sites is usually based on a risk-based approach for the definition of the remediation goals, which relies on the well known ASTM-RBCA standard procedure. In this procedure, migration of contaminants is described through simple analytical models and the source contaminants' concentration is supposed to be constant throughout the entire exposure period, i.e. 25-30 years. The latter assumption may often result over-protective of human health, leading to unrealistically low remediation goals. The aim of this work is to propose an alternative model taking in account the source depletion, while keeping the original simplicity and analytical form of the ASTM-RBCA approach. The results obtained by the application of this model are compared with those provided by the traditional ASTM-RBCA approach, by a model based on the source depletion algorithm of the RBCA ToolKit software and by a numerical model, allowing to assess its feasibility for inclusion in risk analysis procedures. The results discussed in this work are limited to on-site exposure to contaminated water by ingestion, but the approach proposed can be extended to other exposure pathways. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Adverse effects of salivary contamination for adhesives in restorative dentistry. A literature review.

    PubMed

    Nair, Pooja; Hickel, Reinhard; Ilie, Nicoleta

    2017-06-01

    To review and critically analyze the literature concerning the influence of salivary contamination on the bond quality of adhesives used in restorative materials by comparing and contrasting the different adhesive materials. A detailed search on PUBMED, Cochrane Library, Google Scholar and Web of Science was carried out to identify publications on salivary contamination and dental adhesive materials, from 1990-2017 (March) which resulted in a total of 6,202 web-identified publications. After screening titles/abstracts and de-duplicating, 54 publications were selected that matched the requirements for this review. The condition for selection was English literature concerning the effect of salivary contamination on the adhesives used in restorative dentistry. The obtained articles were systematically evaluated. Salivary contamination of adhesives during restorative procedures statistically (64.6%) showed an adverse effect on adhesives, occurring either at one or many stages of restoration. Methodological dissimilarities impeded the direct comparison of the selected studies. Nevertheless, the 2-step etch and rinse adhesives were relatively less vulnerable to salivary contamination than the others. 65% of the evaluated studies for decontamination achieved improved bonding when the contaminated surface was subjected to some kind of decontamination procedure. However, the duration and other specificities were not standard in all the evaluations and need further research to assess the course of action. It is necessary to do long term studies to evaluate the effectiveness of contaminated adhesive over time. Salivary contamination is a potential cause for poor bond quality of adhesive systems during restorative procedures and to provide a successful treatment, proper care must be taken to ensure the operating area is free from contamination. Understanding the properties of the materials and its constituents as well as considering measures to manage the potential vulnerabilities due to salivary contamination in the area of bonding might help a clinician to produce better results.

  13. Silver-Teflon contamination UV radiation study

    NASA Technical Reports Server (NTRS)

    Muscari, J. A.

    1978-01-01

    Silver-Teflon (Ag/FEP) is planned to be used as the thermal control material covering the radiator surfaces on the shuttle orbiter payload bay doors. These radiators require the use of materials that have a very low solar absorptance and a high emittance for heat rejection. However, operationally, materials used on these critical radiator surfaces, such as silver-Teflon, will be exposed to a variety of conditions which include both the natural as well as the induced environments from the Shuttle Orbiter. A complete test facility was assembled, and detailed test procedures and a test matrix were developed. Measurements of low solar absorptance were taken before and after contamination, at intervals during irradiation, and after sample cleaning to fulfill all the requirements.

  14. Aflatoxin M1 in Pasteurized Milk in Babol city, Mazandaran Province, Iran.

    PubMed

    Sefidgar, Saa; Mirzae, M; Assmar, M; Naddaf, Sr

    2011-01-01

    Aflatoxin M(1) (AFM(1)) is the metabolite of aflatoxin B1 (AFB(1)) and is found in milk when lactating animals are fed with contaminated feedstuff. The presence of AFM(1) in milk, pose a major risk for humans especially kids as it can have immunosuppressive, mutagenic, teratogenic and carcinogenic effects. The present study is aimed to investigate the occurrence of AFM(1) in subsidized pasteurized milk in Babol, Mazandaran Province, Iran. Some 72 pasteurized milk packages were collected from supermarkets in various districts of city during January to March 2006. Milk samples were centrifuged and amounts of 100 μl of skimmed milk were tested for AFM(1) contamination by competitive ELISA. All the samples (100%) exhibited contamination with AFM(1). The contamination levels means in January, February, and March were 227.85, 229.64, and 233.1ng/l, respectively. The amount of AFM(1) in all the samples were above 50ng/l, the threshold set by the European community regulations. Monitoring of AFM(1) level should be part of quality control procedures in dairy factories, particularly the ones providing infant's milk. Production of safer and healthier milk and other dairy products with minimum AFM(1) level can be achieved by adopting prophylactic measures including control of humidity and water content of feedstuff, which favors mould production.

  15. Aflatoxin M1 in Pasteurized Milk in Babol city, Mazandaran Province, Iran

    PubMed Central

    Sefidgar, SAA; Mirzae, M; Assmar, M; Naddaf, SR

    2011-01-01

    Background: Aflatoxin M1 (AFM1) is the metabolite of aflatoxin B1 (AFB1) and is found in milk when lactating animals are fed with contaminated feedstuff. The presence of AFM1 in milk, pose a major risk for humans especially kids as it can have immunosuppressive, mutagenic, teratogenic and carcinogenic effects. The present study is aimed to investigate the occurrence of AFM1 in subsidized pasteurized milk in Babol, Mazandaran Province, Iran. Methods: Some 72 pasteurized milk packages were collected from supermarkets in various districts of city during January to March 2006. Milk samples were centrifuged and amounts of 100 μl of skimmed milk were tested for AFM1 contamination by competitive ELISA. Results: All the samples (100%) exhibited contamination with AFM1. The contamination levels means in January, February, and March were 227.85, 229.64, and 233.1ng/l, respectively. The amount of AFM1 in all the samples were above 50ng/l, the threshold set by the European community regulations. Conclusion: Monitoring of AFM1 level should be part of quality control procedures in dairy factories, particularly the ones providing infant’s milk. Production of safer and healthier milk and other dairy products with minimum AFM1 level can be achieved by adopting prophylactic measures including control of humidity and water content of feedstuff, which favors mould production. PMID:23113064

  16. Manual sorting to eliminate aflatoxin from peanuts.

    PubMed

    Galvez, F C F; Francisco, M L D L; Villarino, B J; Lustre, A O; Resurreccion, A V A

    2003-10-01

    A manual sorting procedure was developed to eliminate aflatoxin contamination from peanuts. The efficiency of the sorting process in eliminating aflatoxin-contaminated kernels from lots of raw peanuts was verified. The blanching of 20 kg of peanuts at 140 degrees C for 25 min in preheated roasters facilitated the manual sorting of aflatoxin-contaminated kernels after deskinning. The manual sorting of raw materials with initially high aflatoxin contents (300 ppb) resulted in aflatoxin-free peanuts (i.e., peanuts in which no aflatoxin was detected). Verification procedures showed that the sorted sound peanuts contained no aflatoxin or contained low levels (<15 ppb) of aflatoxin. The results obtained confirmed that the sorting process was effective in separating contaminated peanuts whether or nor contamination was extensive. At the commercial level, when roasters were not preheated, the dry blanching of 50 kg of peanuts for 45 to 55 min facilitated the proper deskinning and subsequent manual sorting of aflatoxin-contaminated peanut kernels from sound kernels.

  17. Modeling of Transmittance Degradation Caused by Optical Surface Contamination by Atomic Oxygen Reaction with Adsorbed Silicones

    NASA Technical Reports Server (NTRS)

    Snyder, Aaron; Banks, Bruce; Miller, Sharon; Stueber, Thomas; Sechkar, Edward

    2001-01-01

    A numerical procedure is presented to calculate transmittance degradation caused by contaminant films on spacecraft surfaces produced through the interaction of orbital atomic oxygen (AO) with volatile silicones and hydrocarbons from spacecraft components. In the model, contaminant accretion is dependent on the adsorption of species, depletion reactions due to gas-surface collisions, desorption, and surface reactions between AO and silicone producing SiO(x), (where x is near 2). A detailed description of the procedure used to calculate the constituents of the contaminant layer is presented, including the equations that govern the evolution of fractional coverage by specie type. As an illustrative example of film growth, calculation results using a prototype code that calculates the evolution of surface coverage by specie type is presented and discussed. An example of the transmittance degradation caused by surface interaction of AO with deposited contaminant is presented for the case of exponentially decaying contaminant flux. These examples are performed using hypothetical values for the process parameters.

  18. Verification approach for the Shuttle/Payload Contamination Evaluation computer program - Spacelab induced environment

    NASA Technical Reports Server (NTRS)

    Bareiss, L. E.

    1978-01-01

    The paper presents a compilation of the results of a systems level Shuttle/payload contamination analysis and related computer modeling activities. The current technical assessment of the contamination problems anticipated during the Spacelab program are discussed and recommendations are presented on contamination abatement designs and operational procedures based on experience gained in the field of contamination analysis and assessment, dating back to the pre-Skylab era. The ultimate test of the Shuttle/Payload Contamination Evaluation program will be through comparison of predictions with measured levels of contamination during actual flight.

  19. Effectiveness of disinfectant wipes for decontamination of bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital.

    PubMed

    Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu

    2013-02-01

    To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.

  20. A single-dose regimen for antimicrobial prophylaxis to prevent perioperative infection in urological clean and clean-contaminated surgery.

    PubMed

    Higuchi, Yoshihide; Takesue, Yoshio; Yamada, Yusuke; Ueda, Yasuo; Suzuki, Toru; Aihara, Kinue; Maruyama, Takuo; Kondoh, Nobuyuki; Nojima, Michio; Yamamoto, Shingo

    2011-04-01

    A single dose of antimicrobial prophylaxis (AMP) was administered parenterally for the prevention of perioperative infection in a total of 788 patients undergoing urological surgery, including 380 endoscopic-instrumental, 328 clean, and 80 clean-contaminated operations performed at our institute between January 2007 and December 2009. Surgical site infections (SSIs), urinary tract infections (UTIs), and remote infections (RIs) were prospectively surveyed. The definition for a single dose of AMP allowed for the administration of an additional dose of an antimicrobial during surgery if the procedure was longer than 3 h, but not for the parenteral or oral administration at the end of the procedure in the recovery room, or at a later time over a period of more than 24 h. UTI was observed in 12 (3.2%) patients after endoscopic-instrumental operation, 1 (0.3%) after clean operation, and 1 (0.9%) after clean-contaminated operation. SSI was observed in 2 (0.6%) patients after clean operation but in none after clean-contaminated operations. RI was observed in 1 (0.3%) patient after endoscopic-instrumental operation, 3 (0.9%) after clean operation, and none after clean-contaminated operations. A single-dose regimen of AMP was effective and feasible for the prevention of perioperative infections, including SSIs, UTIs, and RIs, in endoscopic-instrumental, clean, and clean-contaminated urological surgical procedures.

  1. Post-operative shampoo effects in neurosurgical patients: a pilot experimental study.

    PubMed

    Palese, Alvisa; Moreale, Renzo; Noacco, Massimo; Pistrino, Flavia; Mastrolia, Irene; Sartor, Assunta; Scarparo, Claudio; Skrap, Miran

    2015-04-01

    Neurosurgical site infections are an important issue. Among the acknowledged preventive tactics, the non-shaving technique is well established in the neurosurgical setting. However, given that patient's hair around the surgical site may retain biologic material that emerges during the surgical procedure or that may simply become dirty, which may increase the risk of surgical site infections, if and when shampooing should be offered remains under debate. A pilot experimental study was undertaken from 2011 to 2012. A series of neurosurgical patients not affected by conditions that would increase the risk of post-operative infection were assigned randomly to the exposed group (receiving shampoo 72 h after surgical procedure) or control group (receiving standard dressing surveillance without shampooing). Comfort, surgical site contamination (measured as the number of colony-forming units [CFU]), and SSIs at 30 d after surgery were the main study outcomes. A total of 53 patients were included: 25 (47.2%) received a shampoo after 72 h whereas 28 (52.8%) received standard care. Patients who received a shampoo reported a similar level of comfort (average=8.04; standard deviation [SD] 1.05) compared with those receiving standard care (average 7.3; SD 3.2) although this was not statistically significant (p=0.345). No statistically significant difference emerged in the occurrence of surgical site contamination between the groups, and no SSIs were detected within 30 d. In our pilot study, the results of which are not generalizable because of the limited sample of patients involved, a gentle shampoo offered 72 h after the surgical procedure did not increase the SSIs occurrence or the contamination of the surgical site, although it may increase the perception of comfort by patients. Further studies are strongly recommended involving a larger sample size and designed to include more diversified neurosurgical patients undergoing surgical procedures in different centers.

  2. [Evaluation of phosphate-containing amendments on remediation effect and influential factors in a lead/zinc mining tailings contaminated soil using TCLP and forms].

    PubMed

    Chen, Jian-Jun; Yu, Tian-Ming; Wang, Bi-Ling; Xie, Zheng-Miao

    2010-01-01

    A pot experiment was conducted to evaluate the effects of phosphate-containing (P) amendments on the toxicity and bioavailability of Pb and Zn in a soil contaminated by mining tailings using toxicity characteristic leaching procedure (TCLP) and water soluble, exchangeable leaching procedures in order to find out the appropriate P application rates to reduce the soil TCLP extractable Pb to below the USA EPA's regulatory limit levels. The results showed that TCLP extractable Pb concentrations were significantly decreased by up to 93.3% for MPP treatments and up to 68.5% for SSP treatments after P application. The dose required to reduce leachable Pb below the EPA's regulatory limit level was found to be around the molar ratio of v(P/Pb) = 0.6 for MPP and 1.8 for SSP. It was also found both MPP and SSP could reduce the exchangeable Pb and Zn concentrations that all bio-available Zn forms including water soluble, exchangeable, and TCLP extractable forms in soil were significantly and negatively correlated to soil pH values, indicating that the content of Zn in the soil was mostly controlled by soil pH value even after P application. These results suggest that P as MPP and SSP could successfully decrease the toxicity and bioavailability of Pb and Zn in the contaminated soil.

  3. Infection Rate after Cranial Neurosurgical Procedures: A Prospective Single-Center Study.

    PubMed

    Strahm, Carol; Albrich, Werner C; Zdravkovic, Vilijam; Schöbi, Barbara; Hildebrandt, Gerhard; Schlegel, Matthias

    2018-03-01

    To determine infection rate (IR) and to identify modifiable risk factors (RF) in cranial neurosurgery in a neurosurgical department for tertiary referral as part of an infection control surveillance to reduce surgical site infections (SSI). A prospective SSI incidence cohort study from February 2013 to January 2014 was performed in a tertiary-care neurosurgical teaching hospital and referral center. All consecutive adults undergoing any cranial neurosurgical procedure were included. Data were collected by a trained member of the infection control staff during the twice-weekly visits of the hospitalized patients. Follow-up was 30 days (procedures without implant) and 1 year (procedures involving permanent implants). SSI was diagnosed according to criteria of CDC. A total of 317 patients undergoing 333 index procedures were included. The median age was 61 years (range, 17-91 years) and 46% were female. Survival in patients with completed follow-up was 76% (196/258). Overall, IR was 7.2% (24/333 index procedures); in 96% (23/24), a neurosurgical implant was involved. The IR of extraventricular drainage (EVD) was 12.5% (13.1/1000 EVD days). The main causative pathogens were Staphylococcus aureus followed by coagulase-negative staphylococci and Propionibacterium acnes. Independent RF for neurosurgical SSI were EVD as part of the index operation and body mass index >25 kg/m 2 . IR was in accordance with recent prospective single-center studies (reported IR between 1.6% and 9%). EVD placement was identified as the strongest modifiable RF for SSI in cranial neurosurgical procedures. The need for standard infection control procedures for the insertion and maintenance of EVDs to avoid their contamination is reinforced. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A new experimental procedure of outgassing rate measurement to obtain more precise deposition properties of materials

    NASA Astrophysics Data System (ADS)

    Miyazaki, Eiji; Shimazaki, Kazunori; Numata, Osamu; Waki, Miyuki; Yamanaka, Riyo; Kimoto, Yugo

    2016-09-01

    Outgassing rate measurement, or dynamic outgassing test, is used to obtain outgassing properties of materials, i.e., Total Mass Loss, "TML," and Collected Volatile Condensed Mass, "CVCM." The properties are used as input parameters for executing contamination analysis, e.g., calculating a prediction of deposition mass on a surface in a spacecraft caused by outgassed substances from contaminant sources onboard. It is likely that results obtained by such calculations are affected by the input parameters. Thus, it is important to get a sufficient experimental data set of outgassing rate measurements for extract good outgassing parameters of materials for calculation. As specified in the standard, ASTM E 1559, TML is measured by a QCM sensor kept at cryogenic temperature; CVCMs are measured at certain temperatures. In the present work, the authors propose a new experimental procedure to obtain more precise VCMs from one run of the current test time with the present equipment. That is, two of four CQCMs in the equipment control the temperature to cool step-by-step during the test run. It is expected that the deposition rate, that is sticking coefficient, with respect to temperature could be discovered. As a result, the sticking coefficient can be obtained directly between -50 and 50 degrees C with 5 degrees C step. It looks like the method could be used as an improved procedure for outgassing rate measurement. The present experiment also specified some issues of the new procedure. It will be considered in future work.

  5. The evaluation of readiness of medical personnel to act under conditions of chemical contamination.

    PubMed

    Szarpak, Łukasz; Kurowski, Andrzej

    2014-08-01

    We evaluated the knowledge of physicians, nurses, and paramedics in Poland about the procedures in a chemical contamination. An anonymous survey was mailed to 600 randomly selected physicians, nurses, and paramedics. The survey included questions concerning the process of decontamination, knowledge of toxidromes, and the use of selected antidotes. Completed surveys were received from 510 respondents (85%). A very low level of knowledge was observed regarding decontamination techniques (from 8.3% to 34.2%), use of antidotes (from 13.7% to 61%), and knowledge of toxidromes (from 10.2% to 22.7%). Our findings showed that for all aspects of chemical rescue procedures queried, the knowledge of medical personnel was not satisfactory. Both practical and theoretical training of medical personnel is urgently needed for life-saving procedures during a chemical contamination.

  6. Urban wet-weather flows: sources of fecal contamination impacting on recreational waters and threatening drinking-water sources.

    PubMed

    Marsalek, Jiri; Rochfort, Quintin

    Discharges of urban stormwater and combined sewer overflows (CSOs) contribute to fecal contamination of urban waters and need to be considered in planning the protection of recreational waters and sources of drinking water. Stormwater characterization indicates that Escherichia coli counts in stormwater typically range from 103 to 104 units per 100 ml. Higher counts (10(5) units/100 ml) suggest the presence of cross-connections with sanitary sewers, and such connections should be identified and corrected. Fecal contamination of stormwater may be attenuated prior to discharge into surface waters by stormwater management measures, which typically remove suspended solids and attached bacteria. Exceptionally, stormwater discharges in the vicinity of swimming beaches are disinfected. The levels of indicator bacteria in CSOs can be as high as 10(6) E. coli per 100 ml. Consequently, the abatement of fecal contamination of CSOs is now considered in the design of CSO control and treatment, as for example stipulated in the Ontario Procedure F-5-5. CSO abatement options comprise combin ations of storage and treatment, in which the CSO treatment generally includes disinfection by ultraviolet (UV) irradiation. Finally, indicator bacteria data from Sarnia (Ontario) were used to demonstrate some fecal contamination impacts of wet-weather flows. In wet weather, the microbiological quality of riverine water worsened as a result of CSO and stormwater discharges, and the recreational water guidelines for indicator organisms were exceeded most of the time. Local improvements in water quality were feasible by source controls and diversion of polluted water.

  7. Isolation of biologically-active exosomes from human plasma.

    PubMed

    Muller, Laurent; Hong, Chang-Sook; Stolz, Donna B; Watkins, Simon C; Whiteside, Theresa L

    2014-09-01

    Effects of exosomes present in human plasma on immune cells have not been examined in detail. Immunological studies with plasma-derived exosomes require their isolation by procedures involving ultracentrifugation. These procedures were largely developed using supernatants of cultured cells. To test biologic activities of plasma-derived exosomes, methods are necessary that ensure adequate recovery of exosome fractions free of contaminating larger vesicles, cell fragments and protein/nucleic acid aggregates. Here, an optimized method for exosome isolation from human plasma/serum specimens of normal controls (NC) or cancer patients and its advantages and pitfalls are described. To remove undesirable plasma-contaminating components, ultrafiltration of differentially-centrifuged plasma/serum followed by size-exclusion chromatography prior to ultracentrifugation facilitated the removal of contaminants. Plasma or serum was equally acceptable as a source of exosomes based on the recovered protein levels (in μg protein/mL plasma) and TEM image quality. Centrifugation on sucrose density gradients led to large exosome losses. Fresh plasma was the best source of morphologically-intact exosomes, while the use of frozen/thawed plasma decreased exosome purity but not their biologic activity. Treatments of frozen plasma with DNAse, RNAse or hyaluronidase did not improve exosome purity and are not recommended. Cancer patients' plasma consistently yielded more isolated exosomes than did NCs' plasma. Cancer patients' exosomes also mediated higher immune suppression as evidenced by decreased CD69 expression on responder CD4+ T effector cells. Thus, the described procedure yields biologically-active, morphologically-intact exosomes that have reasonably good purity without large protein losses and can be used for immunological, biomarker and other studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Purification of contaminated water by filtration through porous glass

    NASA Technical Reports Server (NTRS)

    Wydeven, T.; Leban, M. I.

    1972-01-01

    Method for purifying water that is contaminated with mineral salts and soluble organic compounds is described. Method consists of high pressure filtration of contaminated water through stabilized porous glass membranes. Procedure for conducting filtration is described. Types of materials by percentage amounts removed from the water are identified.

  9. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    PubMed

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  10. Fluress, fluorescein and benoxinate: recovery from bacterial contamination.

    PubMed

    Yolton, D P; German, C J

    1980-05-01

    The ability to recover from bacterial contaminations with Staphylococcus auresus and Pseudomonas aeruginosa was determined for three optometric DPAs: Fluress, fluorescein and benoxinate. Results show that Fluress recovers from contamination more rapidly than benoxinate or fluorescein. This ability to recover from contamination and the relative ease of use of Fluress may make it the DPA choice for a number of optometric procedures including applanation tonometry.

  11. Pyrethroid Treatment of Cattle for Tsetse Control: Reducing Its Impact on Dung Fauna

    PubMed Central

    Vale, Glyn A.; Hargrove, John W.; Chamisa, Andrew; Grant, Ian F.; Torr, Stephen J.

    2015-01-01

    Background African trypansomiases of humans and animals can be controlled by attacking the vectors, various species of tsetse fly. Treatment of cattle with pyrethroids to kill tsetse as they feed is the most cost-effective method. However, such treatments can contaminate cattle dung, thereby killing the fauna which disperse the dung and so play an important role in soil fertility. Hence there is a need to identify cost-effective methods of treating cattle with minimal impact on dung fauna. Methodology/Principal Findings We used dung beetles to field bioassay the levels of dung contamination following the use of spray and pour-on formulations of deltamethrin, applied to various parts of the body of cattle in Zimbabwe. Results suggested that dung was contaminated by contact with insecticide on the body surface as the cattle defecated, and by ingestion of insecticide as the cattle licked themselves. Death of dung beetles was reduced to negligible levels by using only the spray and applying it to the legs and belly or legs alone, i.e., places where most tsetse feed. Conclusion/Significance The restricted applications suitable for minimising the impact on dung fauna have the collateral benefits of improving the economy and convenience of cattle treatments for tsetse control. The demonstration of collateral benefits is one of the surest ways of promoting environmentally friendly procedures. PMID:25738836

  12. Soil Contamination and Remediation Strategies. Current research and future challenge

    NASA Astrophysics Data System (ADS)

    Petruzzelli, G.

    2012-04-01

    Soil contamination: the heritage of industrial development Contamination is only a part of a whole set of soil degradation processes, but it is one of paramount importance since soil pollution greatly influences the quality of water, food and human health. Soil contamination has been identified as an important issue for action in the European strategy for soil protection, it has been estimated that 3.5 million of sites are potentially contaminated in Europe. Contaminated soils have been essentially discovered in industrial sites landfills and energy production plants, but accumulation of heavy metals and organic compounds can be found also in agricultural land . Remediation strategies. from incineration to bioremediation The assessment of soil contamination is followed by remedial action. The remediation of contaminated soils started using consolidates technologies (incineration inertization etc.) previously employed in waste treatment,. This has contributed to consider a contaminated soil as an hazardous waste. This rough approximation was unfortunately transferred in many legislations and on this basis soil knowledge have been used only marginally in the clean up procedures. For many years soil quality has been identified by a value of concentration of a contaminant and excavation and landfill disposal of soil has been largely used. In the last years the knowledge of remediation technology has rapidly grown, at present many treatment processes appear to be really feasible at field scale, and soil remediation is now based on risk assessment procedures. Innovative technologies, largely dependent on soil properties, such as in situ chemical oxidation, electroremediation, bioventing, soil vapor extraction etc. have been successfully applied. Hazardous organic compounds are commonly treated by biological technologies, biorememdiation and phytoremediation, being the last partially applied also for metals. Technologies selection is no longer exclusively based on eliminating the source of pollution, but also on blocking the pathways from contaminants to receptors or reducing the exposure to contaminants,. Future challenge integration of sustainability into remediation decision-making. Soil is not a waste! There is a growing interest in the clean up approaches that maintain soil quality after remediation treatments. This issue is of great importance in the U.S.A. where the EPA from 2009 is promoting innovative clean-up strategies (Green Remediation). Green remediation is defined as the practice of considering all environmental effects of remedy and incorporating options to maximize environmental benefit of cleanup actions . These remediation strategies restore contaminated sites to productive use with a great attention to the global environmental quality, including the preservation of soil functionality according to the following principles: use minimally invasive technologies; use passive energy technologies such as bioremediation and phytoremediation as primary remedies or finishing steps where possible and effective; minimize soil and habitat disturbance; minimize bioavailability of contaminants trough adequate contaminant source and plume control If we move from the current definition of remedial targets based on total concentrations, technologies with low impact on the environment can be utilized reducing the wrong choice to disposal soil in landfill destroying quickly a not renewable essential resource.

  13. Cleaning procedure for improved photothermal background of toroidal optical microresonators

    NASA Astrophysics Data System (ADS)

    Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.

    2016-09-01

    High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.

  14. Engineering strategies for the design of plant nutrient delivery systems for use in space: approaches to countering microbiological contamination

    NASA Technical Reports Server (NTRS)

    Gonzales, A. A.; Schuerger, A. C.; Barford, C.; Mitchell, R.

    1996-01-01

    Microbiological contamination of crops within space-based plant growth research chambers has been postulated as a potentially significant problem. Microbial infestations; fouling of Nutrient Delivery System (NDS) fluid loops; and the formation of biofilms have been suggested as the most obvious and important manifestations of the problem. Strict sanitation and quarantine procedures will reduce, but not eliminate, microbial species introduced into plant growth systems in space habitats. Microorganisms transported into space most likely will occur as surface contaminants on spacecraft components, equipment, the crew, and plant-propagative materials. Illustrations of the potential magnitude of the microbiological contamination issue will be drawn from the literature and from documentation of laboratory and commercial field experience. Engineering strategies for limiting contamination and for the development of countermeasures will be described. Microbiological control technologies and NDS hardware will be discussed. Configurations appropriate for microgravity research facilities, as well as anticipated bio-regenerative life support system implementations, will be explored. An efficiently designed NDS, capable of adequately meeting the environmental needs of crop plants in space, is considered to be critical in both the research and operational domains. Recommended experiments, tests, and technology developments, structured to allow the development of prudent engineering solutions also will be presented.

  15. Engineering Strategies for the Design of Plant Nutrient Delivery Systems for Use in Space: Approaches to Countering Microbiological Contamination

    NASA Technical Reports Server (NTRS)

    Gonzales, A. A.; Schuerger, A. C.; Mitchell, R.; Harper, Lynn D. (Technical Monitor)

    1994-01-01

    Microbiological contamination of crops within space-based crop growth research chambers has been postulated as a potentially significant problem. Microbial infestations; fouling of Nutrient Delivery System (NDS) fluid loops; and the formation of biofilms, have been suggested as the most obvious and important manifestations of the problem. Strict sanitation and quarantine procedures will reduce, but not eliminate, microbial species introduced into plant growing systems in space habitats. Microorganisms transported into space will most likely occur as contaminants on spacecraft components, equipment, the crew, and plant-propagative materials. Illustrations of the potential magnitude of the microbiological contamination issue will be drawn from the literature and from documentation of laboratory and commercial field experience. Engineering strategies for limiting contamination and for the development of countermeasures will be described. Microbiological control technologies and NDS hardware will be discussed. Configurations appropriate for microgravity research facilities, as well as anticipated bio-regenerative life support system implementations, will be explored. An efficiently designed NDS, capable of adequately meeting the environmental needs of crop plants in space, is considered to be critical in both the research and operational domains. Recommended experiments, tests and technology developments, structured to allow the development of prudent engineering solutions, will also be presented.

  16. Remediation following Man-made or Natural Disasters -Homeland Security Research

    EPA Pesticide Factsheets

    EPA develops procedures mitigate contamination and to remediate the environment following public health and environmental incidents and disasters. Contamination incidents involving urban areas could require the decontamination of

  17. Air Sampling Filter

    NASA Technical Reports Server (NTRS)

    1980-01-01

    General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

  18. Piloted Simulation to Evaluate the Utility of a Real Time Envelope Protection System for Mitigating In-Flight Icing Hazards

    NASA Technical Reports Server (NTRS)

    Ranaudo, Richard J.; Martos, Borja; Norton, Bill W.; Gingras, David R.; Barnhart, Billy P.; Ratvasky, Thomas P.; Morelli, Eugene

    2011-01-01

    The utility of the Icing Contamination Envelope Protection (ICEPro) system for mitigating a potentially hazardous icing condition was evaluated by 29 pilots using the NASA Ice Contamination Effects Flight Training Device (ICEFTD). ICEPro provides real time envelope protection cues and alerting messages on pilot displays. The pilots participating in this test were divided into two groups; a control group using baseline displays without ICEPro, and an experimental group using ICEPro driven display cueing. Each group flew identical precision approach and missed approach procedures with a simulated failure case icing condition. Pilot performance, workload, and survey questionnaires were collected for both groups of pilots. Results showed that real time assessment cues were effective in reducing the number of potentially hazardous upset events and in lessening exposure to loss of control following an incipient upset condition. Pilot workload with the added ICEPro displays was not measurably affected, but pilot opinion surveys showed that real time cueing greatly improved their situation awareness of a hazardous aircraft state.

  19. In situ stabilization remediation of cadmium contaminated soils of wastewater irrigation region using sepiolite.

    PubMed

    Sun, Yuebing; Sun, Guohong; Xu, Yingming; Wang, Lin; Lin, Dasong; Liang, Xuefeng; Shi, Xin

    2012-01-01

    The effects of immobilization remediation of Cd-contaminated soils using sepiolite on soil pH, enzyme activities and microbial communities, TCLP-Cd (toxicity characteristic leaching procedure-Cd) concentration, and spinach (Spinacia oleracea) growth and Cd uptake and accumulation were investigated. Results showed that the addition of sepiolite could increase soil pH, while the TCLP-Cd concentration in soil was decreased with increasing sepiolite. The changes of soil enzyme activities and bacteria number indicated that a certain metabolic recovery occurred after the sepiolite treatments, and spinach shoot biomass increased by 58.5%-65.5% in comparison with the control group when the concentration of sepiolite was < or = 10 g/kg. However, the Cd concentrations in the shoots and roots of spinach decreased with an increase in the rate of sepiolite, experiencing 38.4%-59.1% and 12.6%-43.6% reduction, respectively, in contrast to the control. The results indicated that sepiolite has the potential for success on a field scale in reducing Cd entry into the food chain.

  20. Ground-water sampling methods and quality-control data for the Red River of the North basin, Minnesota, North Dakota, and South Dakota, 1993-95

    USGS Publications Warehouse

    Menheer, M.A.; Brigham, M.E.

    1997-01-01

    Quality-control data demonstrated that most constituents measured for this study yielded reproducible data, with low to undetectable contamination from the sampling and analytical procedures. Several constituents were occasionally or frequently detected in blank samples at levels similar to low-concentration ground-water-quality samples. For example, iron was detected in 75 percent of the blank samples, with a maximum concentration of 27 [ig/L, indicating that iron contamination may interfere with its determination at low levels in ground waters. Copper, aluminum, and dissolved organic carbon concentrations in blank samples overlap those determined in ground-waterquality samples, thereby precluding quantitative reporting of those constituents. Most pesticide data are reproducible, with minimal bias. Some pesticides had low but consistent recoveries; these data may be useful if spike and surrogate data are carefully considered. Data for some pesticides measured in this study should not be quantitatively reported or used, because they may underestimate the concentrations of those pesticides in ground waters.

  1. Three-dimensional modeling, estimation, and fault diagnosis of spacecraft air contaminants.

    PubMed

    Narayan, A P; Ramirez, W F

    1998-01-01

    A description is given of the design and implementation of a method to track the presence of air contaminants aboard a spacecraft using an accurate physical model and of a procedure that would raise alarms when certain tolerance levels are exceeded. Because our objective is to monitor the contaminants in real time, we make use of a state estimation procedure that filters measurements from a sensor system and arrives at an optimal estimate of the state of the system. The model essentially consists of a convection-diffusion equation in three dimensions, solved implicitly using the principle of operator splitting, and uses a flowfield obtained by the solution of the Navier-Stokes equations for the cabin geometry, assuming steady-state conditions. A novel implicit Kalman filter has been used for fault detection, a procedure that is an efficient way to track the state of the system and that uses the sparse nature of the state transition matrices.

  2. Overview of the U.S. EPA/SERDP/ESTCP: Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’s Manual

    EPA Science Inventory

    Passive sampling can be used for applications at contaminated sediment sites including performing assessments of contaminant bioavailability (i.e., freely dissolved concentration (Cfree)), conducting remedial investigations and feasibility studies, and assessing the potential for...

  3. 77 FR 38523 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-28

    ... of semivolatile organic compounds in finished drinking water. The method analytes are extracted and... semivolatile organic contaminants: Alachlor, atrazine, polychlorinated biphenyls (PCBs), benzo[a]pyrene... approved EPA Method 525.2, Revision 2.0 for each of the 17 regulated semivolatile organic contaminants. EPA...

  4. Overview of the U.S. EPA/SERDP/ESTCP: Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User’s Manual.

    EPA Science Inventory

    Passive sampling is used for applications at contaminated sediment sites including performing assessments of contaminant bioavailability (i.e., freely dissolved concentration (Cfree)), conducting remedial investigations and feasibility studies, and assessing the potential for con...

  5. The effect of cleaning on blood contamination in the dental surgery following periodontal procedures.

    PubMed

    Edmunds, L M; Rawlinson, A

    1998-10-01

    Blood contamination of 16 surfaces in the dental surgery was investigated using the Kastle-Meyer test for haemoglobin, after three types of periodontal procedures had been performed on a total of 30 patients. The effect of cleaning surfaces contaminated by blood was investigated using the same test. Cleaning materials used in the dental surgery were tested to rule out the possibility of false positive outcomes and the sensitivity of the test was determined prior to the study. The results show a marked variation in the degree of contamination and efficacy of cleaning following treatment. Overall, root planing was associated with the most widespread and frequent blood contamination and gingival surgery the least. The surgery work surface, edge of the spittoon, aspirator tube and ultrasonic scaler handpiece into which the ultrasonic insert fits, were the most frequently contaminated surfaces. The work surface, dentist's pen, light switch and handle were cleaned most effectively. The least effectively cleaned surfaces were the water dispenser switch, aspirator tube, bracket table and ultrasonic scaler handpiece. Methods for reducing this potential source of cross-infection are discussed.

  6. 10 CFR 36.53 - Operating and emergency procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... or pool monitor; (4) Detection of leaking sources, pool contamination, or alarm caused by contamination of pool water; (5) A low or high water level indicator, an abnormal water loss, or leakage from...

  7. Evaluation of Various Radar Data Quality Control Algorithms Based on Accumulated Radar Rainfall Statistics

    NASA Technical Reports Server (NTRS)

    Robinson, Michael; Steiner, Matthias; Wolff, David B.; Ferrier, Brad S.; Kessinger, Cathy; Einaudi, Franco (Technical Monitor)

    2000-01-01

    The primary function of the TRMM Ground Validation (GV) Program is to create GV rainfall products that provide basic validation of satellite-derived precipitation measurements for select primary sites. A fundamental and extremely important step in creating high-quality GV products is radar data quality control. Quality control (QC) processing of TRMM GV radar data is based on some automated procedures, but the current QC algorithm is not fully operational and requires significant human interaction to assure satisfactory results. Moreover, the TRMM GV QC algorithm, even with continuous manual tuning, still can not completely remove all types of spurious echoes. In an attempt to improve the current operational radar data QC procedures of the TRMM GV effort, an intercomparison of several QC algorithms has been conducted. This presentation will demonstrate how various radar data QC algorithms affect accumulated radar rainfall products. In all, six different QC algorithms will be applied to two months of WSR-88D radar data from Melbourne, Florida. Daily, five-day, and monthly accumulated radar rainfall maps will be produced for each quality-controlled data set. The QC algorithms will be evaluated and compared based on their ability to remove spurious echoes without removing significant precipitation. Strengths and weaknesses of each algorithm will be assessed based on, their abilit to mitigate both erroneous additions and reductions in rainfall accumulation from spurious echo contamination and true precipitation removal, respectively. Contamination from individual spurious echo categories will be quantified to further diagnose the abilities of each radar QC algorithm. Finally, a cost-benefit analysis will be conducted to determine if a more automated QC algorithm is a viable alternative to the current, labor-intensive QC algorithm employed by TRMM GV.

  8. Does microbial contamination influence the success of the hematopoietic cell transplantation outcomes?

    PubMed

    Dal, Mehmet Sinan; Tekgündüz, Emre; Çakar, Merih Kızıl; Kaya, Ali Hakan; Namdaroğu, Sinem; Batgi, Hikmetullah; Bekdemir, Filiz; Uncu Ulu, Bahar; Yiğenoğlu, Tuğçe Nur; Kılınç, Ali; İskender, Dicle; Uğur, Bilge; Koçubaba, Şerife; İskender, Gülşen; Altuntaş, Fevzi

    2016-08-01

    Microbial contamination can be a marker for faulty process and is assumed to play an important role in the collection of hematopoietic progenitor cell (HPC) and infusion procedure. We aimed to determine the microbial contamination rates and evaluate the success of hematopoietic cell transplantation (HCT) in patients who received contaminated products. We analyzed microbial contamination records of HPC grafts between 2012 and 2015, retrospectively. Contamination rates of autologous donors were evaluated for at three steps: at the end of mobilization, following processing with dimethyl sulfoxide, and just before stem cell infusion. Grafts of allogeneic donors were assessed only before HCT. A total of 445 mobilization procedures were carried out on 333 (167 autologous and 166 allogeneic) donors. The microbiological contamination of peripheral blood (323/333 donations) and bone marrow (10/333 donations) products were analyzed. Bacterial contamination was detected in 18 of 1552 (1.15 %) culture bottles of 333 donors. During the study period 248 patients underwent HCT and among these patients microbial contamination rate on sample basis was 1.3 % (16/1212). Microbial contamination detected in nine patients (7 autologous; 2 allogeneic). In 8 of 9 patients, a febrile neutropenic attack was observed. The median day for the neutropenic fever was 4 days (0-9). None of the patients died within the post-transplant 30 days who received contaminated products. The use of contaminated products with antibiotic prophylaxis may be safe in terms of the first day of fever, duration of fever, neutrophil, platelet engraftment and duration of hospitalization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  10. Space station contamination control study: Internal combustion, phase 1

    NASA Technical Reports Server (NTRS)

    Ruggeri, Robert T.

    1987-01-01

    Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

  11. Evaluation of the vitreous microbial contamination rate in office-based three-port microincision vitrectomy surgery using Retrector technology.

    PubMed

    Rezende, Flavio A; Qian, Cynthia X; Sapieha, Przemyslaw

    2014-05-01

    To perform a microbiological contamination analysis of the vitreous during office-based micro-incision vitrectomy surgery (MIVS) assessing whether the bacteria detected correlated with patient's ocular conjunctival flora. This is a prospective, interventional, nonrandomized case series of patients undergoing office-based MIVS, anti-VEGF, and dexamethasone intravitreal injections (triple therapy) for the treatment of wet age-related macular degeneration (AMD) and diabetic macular edema (DME).All patients were operated at a small procedure room in an ambulatory clinic of the Department of Ophthalmology, University of Montreal, Quebec, Canada. Conjunctival samples were done before placing the sclerotomies. The MIVS was done with a 23-gauge retractable vitrector, a 27-gauge infusion line, and a 29-gauge chandelier. Undiluted and diluted vitreous were collected for aerobic, anaerobic and fungal cultures. Outcomes measured were bacterial species identification within samples collected from the conjunctiva and the vitreous. Thirty-seven patients (37 eyes) were recruited and completed over 17 months of follow-up. Twenty-eight had wet AMD and nine had DME. There were 13 men and 24 women, with a mean age of 78 years. Eighteen patients (46%) had culture positive conjunctival flora. Twenty-six bacterial colonies were tabulated in total from the conjunctival swabs. All bacteria detected were gram-positive bacteria (100%), most commonly: Staphylococcus epidermitis in 11 (42%) and Corynebacterium sp. in 6 (23%). Only 1/18 patients had more than 3 species isolated, 6/18 patients had 2 species and 11/18 patients had 1 species identified on the conjunctival swab. Only 1 of the 37 undiluted midvitreous samples was culture positive, equating to a contamination rate of 2.7%. None of the diluted vitreous samples were culture positive. All cultures were negative for fungus. No serious postoperative complications occurred, including bacterial endophthalmitis, choroidal detachment, and retinal detachment. This preliminary study of office-based MIVS gives us insights on the ocular surface microbial profile and vitreous contamination rate of performing such procedures outside the OR-controlled environment. Our initial results seem to indicate that there is little risk of bacterial translocation and contamination from the conjunctiva into the vitreous. Therefore, if endophthalmitis occurs post-operatively, the source may likely arise after the procedure. Larger studies are needed to confirm our data.

  12. Precise Th/U-dating of small and heavily coated samples of deep sea corals

    NASA Astrophysics Data System (ADS)

    Lomitschka, Michael; Mangini, Augusto

    1999-07-01

    Marine carbonate skeletons like deep-sea corals are frequently coated with iron and manganese oxides/hydroxides which adsorb additional thorium and uranium out of the sea water. A new cleaning procedure has been developed to reduce this contamination. In this further cleaning step a solution of Na 2EDTA (Na 2H 2T B) and ascorbic acid is used which composition is optimised especially for samples of 20 mg of weight. It was first tested on aliquots of a reef-building coral which had been artificially contaminated with powdered ferromanganese nodule. Applied on heavily contaminated deep-sea corals (scleractinia), it reduced excess 230Th by another order of magnitude in addition to usual cleaning procedures. The measurement of at least three fractions of different contamination, together with an additional standard correction for contaminated carbonates results in Th/U-ages corrected for the authigenic component. A good agreement between Th/U- and 14C-ages can be achieved even for extremely coated corals.

  13. Sampling and Homogenization Strategies Significantly Influence the Detection of Foodborne Pathogens in Meat.

    PubMed

    Rohde, Alexander; Hammerl, Jens Andre; Appel, Bernd; Dieckmann, Ralf; Al Dahouk, Sascha

    2015-01-01

    Efficient preparation of food samples, comprising sampling and homogenization, for microbiological testing is an essential, yet largely neglected, component of foodstuff control. Salmonella enterica spiked chicken breasts were used as a surface contamination model whereas salami and meat paste acted as models of inner-matrix contamination. A systematic comparison of different homogenization approaches, namely, stomaching, sonication, and milling by FastPrep-24 or SpeedMill, revealed that for surface contamination a broad range of sample pretreatment steps is applicable and loss of culturability due to the homogenization procedure is marginal. In contrast, for inner-matrix contamination long treatments up to 8 min are required and only FastPrep-24 as a large-volume milling device produced consistently good recovery rates. In addition, sampling of different regions of the spiked sausages showed that pathogens are not necessarily homogenously distributed throughout the entire matrix. Instead, in meat paste the core region contained considerably more pathogens compared to the rim, whereas in the salamis the distribution was more even with an increased concentration within the intermediate region of the sausages. Our results indicate that sampling and homogenization as integral parts of food microbiology and monitoring deserve more attention to further improve food safety.

  14. Sampling and Homogenization Strategies Significantly Influence the Detection of Foodborne Pathogens in Meat

    PubMed Central

    Rohde, Alexander; Hammerl, Jens Andre; Appel, Bernd; Dieckmann, Ralf; Al Dahouk, Sascha

    2015-01-01

    Efficient preparation of food samples, comprising sampling and homogenization, for microbiological testing is an essential, yet largely neglected, component of foodstuff control. Salmonella enterica spiked chicken breasts were used as a surface contamination model whereas salami and meat paste acted as models of inner-matrix contamination. A systematic comparison of different homogenization approaches, namely, stomaching, sonication, and milling by FastPrep-24 or SpeedMill, revealed that for surface contamination a broad range of sample pretreatment steps is applicable and loss of culturability due to the homogenization procedure is marginal. In contrast, for inner-matrix contamination long treatments up to 8 min are required and only FastPrep-24 as a large-volume milling device produced consistently good recovery rates. In addition, sampling of different regions of the spiked sausages showed that pathogens are not necessarily homogenously distributed throughout the entire matrix. Instead, in meat paste the core region contained considerably more pathogens compared to the rim, whereas in the salamis the distribution was more even with an increased concentration within the intermediate region of the sausages. Our results indicate that sampling and homogenization as integral parts of food microbiology and monitoring deserve more attention to further improve food safety. PMID:26539462

  15. Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study.

    PubMed

    Badran, Mohamad Aboelnour; Moemen, Dalia Mohamed

    2016-09-01

    Autograft preparation for anterior cruciate ligament (ACL) reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of bacterial contamination of hamstring autograft during preparation and when dropped onto the operating room floor and methods of graft decontamination. Sixty hamstring tendon autograft specimens were used as the test group. Excess tendon not used in the ACL procedure was divided into five segments. One segment, at the completion of preparation, was sent for culture as a control; the remaining four segments were dropped onto the floor adjacent to the surgical field for 15 seconds. One segment was cultured without undergoing any further treatment. Cultures were taken from each segment after immersion in 10 % povidone-iodine solution, 4 % chlorhexidine and bacitracin, respectively, for three minutes. Cultures of a skin swab and floor swab were taken at the same time and place that the ACL was dropped. Cultures of control graft tissue from ten patients (16.7 %) were positive for bacteria. No patient developed post-operative infection. Ninety organisms were identified, with Staphylococcus epidermidis being the most common isolate. Grafts rinsed in either bacitracin or 4 % chlorhexidine solutions were less likely to be culture positive. A high rate of contamination can be expected during autograft preparation for ACL reconstruction. Soaking the hamstring autograft in either bacitracin or 4 % chlorhexidine solution is effective for decontamination, particulary if graft is dropped on the floor.

  16. Listeria monocytogenes in Food-Processing Facilities, Food Contamination, and Human Listeriosis: The Brazilian Scenario.

    PubMed

    Camargo, Anderson Carlos; Woodward, Joshua John; Call, Douglas Ruben; Nero, Luís Augusto

    2017-11-01

    Listeria monocytogenes is a foodborne pathogen that contaminates food-processing environments and persists within biofilms on equipment, utensils, floors, and drains, ultimately reaching final products by cross-contamination. This pathogen grows even under high salt conditions or refrigeration temperatures, remaining viable in various food products until the end of their shelf life. While the estimated incidence of listeriosis is lower than other enteric illnesses, infections caused by L. monocytogenes are more likely to lead to hospitalizations and fatalities. Despite the description of L. monocytogenes occurrence in Brazilian food-processing facilities and foods, there is a lack of consistent data regarding listeriosis cases and outbreaks directly associated with food consumption. Listeriosis requires rapid treatment with antibiotics and most drugs suitable for Gram-positive bacteria are effective against L. monocytogenes. Only a minority of clinical antibiotic-resistant L. monocytogenes strains have been described so far; whereas many strains recovered from food-processing facilities and foods exhibited resistance to antimicrobials not suitable against listeriosis. L. monocytogenes control in food industries is a challenge, demanding proper cleaning and application of sanitization procedures to eliminate this foodborne pathogen from the food-processing environment and ensure food safety. This review focuses on presenting the L. monocytogenes distribution in food-processing environment, food contamination, and control in the food industry, as well as the consequences of listeriosis to human health, providing a comparison of the current Brazilian situation with the international scenario.

  17. Location identification for indoor instantaneous point contaminant source by probability-based inverse Computational Fluid Dynamics modeling.

    PubMed

    Liu, X; Zhai, Z

    2008-02-01

    Indoor pollutions jeopardize human health and welfare and may even cause serious morbidity and mortality under extreme conditions. To effectively control and improve indoor environment quality requires immediate interpretation of pollutant sensor readings and accurate identification of indoor pollution history and source characteristics (e.g. source location and release time). This procedure is complicated by non-uniform and dynamic contaminant indoor dispersion behaviors as well as diverse sensor network distributions. This paper introduces a probability concept based inverse modeling method that is able to identify the source location for an instantaneous point source placed in an enclosed environment with known source release time. The study presents the mathematical models that address three different sensing scenarios: sensors without concentration readings, sensors with spatial concentration readings, and sensors with temporal concentration readings. The paper demonstrates the inverse modeling method and algorithm with two case studies: air pollution in an office space and in an aircraft cabin. The predictions were successfully verified against the forward simulation settings, indicating good capability of the method in finding indoor pollutant sources. The research lays a solid ground for further study of the method for more complicated indoor contamination problems. The method developed can help track indoor contaminant source location with limited sensor outputs. This will ensure an effective and prompt execution of building control strategies and thus achieve a healthy and safe indoor environment. The method can also assist the design of optimal sensor networks.

  18. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    PubMed

    Iervolino, Matteo; Mancini, Benedetta; Cristino, Sandra

    2017-09-26

    The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella , P. aeruginosa , and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H₂O₂) and silver salts (Ag⁺), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L . pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H₂O₂/Ag⁺ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease ( p < 0.05) in Legionella concentration (1.77 Log cfu/L). The same trend was observed for P . aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health.

  19. Case-crossover study of Burkholderia cepacia complex bloodstream infection associated with contaminated intravenous bromopride.

    PubMed

    Martins, Ianick Souto; Pellegrino, Flávia Lúcia Piffano Costa; Freitas, Andrea d'Avila; Santos, Marisa da Silva; Ferraiuoli, Giovanna Ianini d'Alemeida; Vasques, Márcia Regina Guimarães; Amorim, Efigenia Lourdes Teixeira; Oliveira, Sandra; Nouér, Simone Aranha; Cardoso, Fernando Luiz Lopes; Mascarenhas, Luiz Affonso; Magalhães, Ana Cristina Gouveia; Cleinman, Isabella Barbosa; Figueiredo, Agnes Marie Sá; Moreira, Beatriz Meurer

    2010-05-01

    To investigate an outbreak of healthcare-associated Burkholderia cepacia complex (BCC) primary bloodstream infections (BCC-BSI). Case-crossover study in a public hospital, a university hospital and a private hospital in Rio de Janeiro, Brazil, from March 2006 to May 2006. Twenty-five patients with BCC-BSI. After determining the date BCC-BSI symptoms started for each patient, 3 time intervals of data collection were defined, each one with a duration of 3 days: the case period, starting just before BCC-BSI symptoms onset; the control period, starting 6 days before BCC-BSI symptoms onset; and the washout period, comprising the 3 days between the case period and the control period. Exposures evaluated were intravascular solutions and invasive devices and procedures. Potential risk factors were identified by using the McNemar chi(2) adjusted test. Cultures of samples of potentially contaminated solutions were performed. BCC strain typing was performed by pulsed-field gel electrophoresis using SpeI. The statistical analysis revealed that the use of bromopride and dipyrone was associated with BCC-BSI. A total of 21 clinical isolates from 17 (68%) of the 25 patients and an isolate obtained from the bromopride vial were available for strain typing. Six pulsotypes were detected. A predominant pulsotype (A) accounted for 11 isolates obtained from 11 patients (65%) in the 3 study hospitals. Our investigation, using a case-crossover design, of an outbreak of BCC-BSI infections concluded it was polyclonal but likely caused by infusion of contaminated bromopride. The epidemiological finding was validated by microbiological analysis. After recall of contaminated bromopride vials by the manufacturer, the outbreak was controlled.

  20. Determination of the external contamination and cross-contamination by cytotoxic drugs on the surfaces of vials available on the Swiss market.

    PubMed

    Fleury-Souverain, Sandrine; Nussbaumer, Susanne; Mattiuzzo, Marc; Bonnabry, Pascal

    2014-04-01

    The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.

  1. Analysis of Metals Concentration in the Soils of SIPCOT Industrial Complex, Cuddalore, Tamil Nadu

    PubMed Central

    Mathivanan, V.; Prabavathi, R.; Prithabai, C.; Selvisabhanayakam

    2010-01-01

    Phytoremediation is a promising area of new research, both for its low cost and great benefit to society in the clean retrieval of contaminated sites. Phytoremediation is the use of living green plants for in situ risk reduction and/or removal of contaminants from contaminated soil, water, sediments, and air. Specially selected or engineered plants are used in the process. The soil samples were taken from Cuddalore Old Town (OT) and the samples from SIPCOT industrial complex, which was the study area and analyzed for various metals concentrations. Fifteen metals have been analyzed by adopting standard procedure. The detection limits of metal concentration are drawn as control. The various (15) metal concentrations in the soil samples were found higher in soil taken from SIPCOT industrial complex, compared with samples taken from Cuddalore OT. In all the observations, it was found that most of the metals like calcium, cadmium, chromium, cobalt, nickel, and zinc showed maximum concentrations, whereas arsenic, antimony, lead, magnesium, sodium have shown minimum concentrations, both when compared with control. From the present study, it was found that the soil collected from SIPCOT complex area were more polluted due to the presence of various industrial effluents, municipal wastes, and sewages when compared with the soil collected from Cuddalore OT. PMID:21170256

  2. Effect of clay minerals and nanoparticles on chromium fractionation in soil contaminated with leather factory waste.

    PubMed

    Taghipour, Marzieh; Jalali, Mohsen

    2015-10-30

    This study was conducted to investigate the effect of time, clay minerals and nanoparticles (NPs) on chromium (Cr) fractionation in a soil contaminated with leather factory waste (LFW). Soil was mixed with LFW, then, the contaminated soils were treated with clay minerals (bentonite and zeolite) and nanoparticles (MgO, TiO2 and ZnO) at 5% and 1%, respectively. The samples were incubated for 15-180 days at 25 °C and constant moisture. After incubation, Cr in control and treated soils was fractionated by the sequential extraction procedure. The distribution of various Cr fractions in control soil indicated that the greatest amounts of Cr were found in the residual fraction (RES) followed by the carbonate (CAR), organic matter (OM) and exchangeable (EXC) fractions. The addition of LFW in soils increased Cr concentration in all fractions. The higher proportion of EXC fraction in the soil treated with LFW indicates its higher potential of leaching and runoff transport. In all treated soils, the RES fraction was increased, while EXC and OM fractions were decreased during incubation. The results indicated that NPs are effective adsorbent for the removal of Cr ions from LFW treated soil, and they could be useful in reducing their environment risk. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Contamination Control for Thermal Engineers

    NASA Technical Reports Server (NTRS)

    Rivera, Rachel B.

    2015-01-01

    The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). This course will cover the basics of Contamination Control, including contamination control related failures, the effects of contamination on Flight Hardware, what contamination requirements translate to, design methodology, and implementing contamination control into Integration, Testing and Launch.

  4. Space station trace contaminant control

    NASA Technical Reports Server (NTRS)

    Olcutt, T.

    1985-01-01

    Different systems for the control of space station trace contaminants are outlined. The issues discussed include: spacecabin contaminant sources, technology base, contaminant control system elements and configuration, approach to contaminant control, contaminant load model definition, spacecraft maximum allowable concentrations, charcoal bed sizing and performance characteristics, catalytic oxidizer sizing and performance characteristics, special sorbent bed sizing, animal and plant research payload problems, and emergency upset contaminant removal. It is concluded that the trace contaminant control technology base is firm, the necessary hardware tools are available, and the previous design philosophy is still applicable. Some concerns are the need as opposed to danger of the catalytic oxidizer, contaminants with very low allowable concentrations, and the impact of relaxing materials requirements.

  5. 76 FR 22059 - Airworthiness Directives; The Boeing Company Model 757 Airplanes, and Model 767-200, 767-300, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-20

    ... procedures to follow to ensure that a fuel filter impending bypass condition due to gross fuel contamination... fuel filter impending bypass condition due to gross fuel contamination is detected in a timely manner... flight crew of a left engine fuel filter contamination and imminent bypass condition, which may indicate...

  6. Tools for measuring surface cleanliness

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  7. Bacteriophages of lactic acid bacteria and their impact on milk fermentations

    PubMed Central

    2011-01-01

    Every biotechnology process that relies on the use of bacteria to make a product or to overproduce a molecule may, at some time, struggle with the presence of virulent phages. For example, phages are the primary cause of fermentation failure in the milk transformation industry. This review focuses on the recent scientific advances in the field of lactic acid bacteria phage research. Three specific topics, namely, the sources of contamination, the detection methods and the control procedures will be discussed. PMID:21995802

  8. An improved method for isolating viruses from asymptomatic carrier fish

    USGS Publications Warehouse

    Amend, Donald F.; Pietsch, John P.

    1972-01-01

    This paper describes a method using elevated levels of penicillin, streptomycin, and nystatin instead of filters to control bacteria and mold contaminants in specimens processed for virus isolation. Filters were shown to significantly reduce the virus concentration. Virus and tissue cultures were not affected by this procedure. In field tests nearly three times more specimens were positive for virus with this method than with the widely used filter technique. Moreover, the cost of materials was less. This method is recommended for inspection and certification purposes.

  9. Contamination sources, serogroups, biofilm-forming ability and biocide resistance of Listeria monocytogenes persistent in tilapia-processing facilities.

    PubMed

    Vázquez-Sánchez, Daniel; Galvão, Juliana Antunes; Oetterer, Marília

    2017-11-01

    The major contamination sources, serogroups, biofilm-forming ability and biocide resistance of Listeria monocytogenes persistent in tilapia-processing facilities were assessed. Twenty-five processing-control points were examined twice in two factories, including whole tilapias, frozen fillets, water and food-contact surfaces. L. monocytogenes were detected in 4 and 20% of points of Factory A and B respectively, but at low concentrations. Contamination was due to inadequate handling of tilapias in the slaughter room of Factory A and to the application of ineffective sanitizing procedures in Factory B. Seven strains were characterized by RAPD-PCR using primers HLWL85, OPM-01 and DAF4. Genotypic similarity allowed tracing the contamination source of tilapia fillets in Factory B and detecting a prevalent strain in Brazilian tilapia-processing facilities. The serogroup II (including the serotype 1/2c) was the most frequently found, followed by serogroup I (1/2a) and III (1/2b), whereas the serotype 4b was not detected. All strains showed high biofilm-forming ability on stainless steel and polystyrene, but biofilm formation was positively correlated with the type of origin surface. Biofilms were highly resistant to peracetic acid and sodium hypochlorite, being required doses higher than those recommended by manufacturers to be eradicated. Peracetic acid was more effective than sodium hypochlorite, but the use of disinfectants with similar mechanisms of action increases the risk of cross-resistance. Case-by-case approaches are thus recommended to determine the sources and degree of contamination present in each factory, which would allow applying precise responses to control the persistence of bacterial pathogens such as L. monocytogenes .

  10. Bacterial contamination of bath-water from spinal cord lesioned patients with pressure ulcers exercising in the water.

    PubMed

    Biering-Sørensen, F; Schröder, A K; Wilhelmsen, M; Lomberg, B; Nielsen, H; Høiby, N

    2000-02-01

    To evaluate the bacterial contamination of the water from the microflora of pressure ulcers in para- and tetraplegic patients, when they were exercising in water at 36 degrees C for half an hour. Twelve spinal cord lesioned (SCL) patients with ulcers participated, and six of the 12 SCL patients with healed ulcers constituted a control group. The evaluation was performed both with and without the ulcer covered with a moisture reactive occlusive dressing, DuoDERM. Bacterial samples were taken from the bath-water before and after the exercise programmes and additionally specimens were obtained from the ulcer, the patients skin and urine, and from the skin of the physiotherapist who exercised the patient. A similar procedure was carried out in the controls. The bacteriologic analyses showed no significant difference in the contamination of the bath-water after exercising with or without DuoDERM covering the ulcers. In half of the patients DuoDERM loosened. After all exercise programmes with or without DuoDERM dressing the water was contaminated with facultative aerobic intestinal bacteria, ie E. faecalis and Enterobacteriaceae (E. coli, Klebsiella species, Proteus species, Enterobacter species). In nearly one-third of the exercise sessions the bath-water was contaminated with P. aeruginosa before starting, and after the exercise programmes one fourth of the ulcers were colonized with these pathogens. The water specimen showed the bacteria from the intestine to be much more prominent than the bacteria coming from the ulcers. Thus the pressure ulcers were of minor importance for the bath-water and ought not to prohibit patients from the potential benefits of water exercise, but chlorination of the water in the training pool seems appropriate.

  11. Risk mitigation by waste-based permeable reactive barriers for groundwater pollution control at e-waste recycling sites.

    PubMed

    Beiyuan, Jingzi; Tsang, Daniel C W; Yip, Alex C K; Zhang, Weihua; Ok, Yong Sik; Li, Xiang-Dong

    2017-02-01

    Permeable reactive barriers (PRBs) have proved to be a promising passive treatment to control groundwater contamination and associated human health risks. This study explored the potential use of low-cost adsorbents as PRBs media and assessed their longevity and risk mitigation against leaching of acidic rainfall through an e-waste recycling site, of which Cu, Zn, and Pb were the major contaminants. Batch adsorption experiments suggested a higher adsorption capacity of inorganic industrial by-products [acid mine drainage sludge (AMDS) and coal fly ash (CFA)] and carbonaceous recycled products [food waste compost (FWC) and wood-derived biochar] compared to natural inorganic minerals (limestone and apatite). Continuous leaching tests of sand columns with 10 wt% low-cost adsorbents were then conducted to mimic the field situation of acidic rainfall infiltration through e-waste-contaminated soils (collected from Qingyuan, China) by using synthetic precipitation leaching procedure (SPLP) solution. In general, Zn leached out first, followed by Cu, and finally delayed breakthrough of Pb. In the worst-case scenario (e.g., at initial concentrations equal to 50-fold of average SPLP result), the columns with limestone, apatite, AMDS, or biochar were effective for a relatively short period of about 20-40 pore volumes of leaching, after which Cu breakthrough caused non-cancer risk concern and later-stage Pb leaching considerably increased both non-cancer and lifetime cancer risk associated with portable use of contaminated water. In contrast, the columns with CFA or FWC successfully mitigated overall risks to an acceptable level for a prolonged period of 100-200 pore volumes. Therefore, with proper selection of low-cost adsorbents (or their mixture), waste-based PRBs is a technically feasible and economically viable solution to mitigate human health risk due to contaminated groundwater at e-waste recycling sites.

  12. Infectivity of prion protein bound to stainless steel wires: a model for testing decontamination procedures for transmissible spongiform encephalopathies.

    PubMed

    Yan, Zheng-Xin; Stitz, Lothar; Heeg, Peter; Pfaff, Eberhard; Roth, Klaus

    2004-04-01

    To establish an animal model to study transmissible spongiform encephalopathy using hamsters and steel wires contaminated with infectious brain materials as transfer vehicles, and, based on this model, to test decontamination procedures against the infectious prion proteins on the steel wires as a near real situation bioassay. Infectious brain materials were given to healthy hamsters intracerebrally either as a suspension or as dried materials on the surface of steel wires. The animals were observed for 18 months. During this period, animals showing definitive clinical signs were euthanized. Decontamination studies were performed by reprocessing contaminated steel wires with different disinfection agents and procedures before implantation. Pathological prion proteins were able to bind to the steel wires and caused disease after the contaminated wires were implanted in the brains of hamsters. When the contaminated wires were treated with different reprocessing procedures before implantation, infectivity was reduced, which was manifested directly by prolonged survival time of the test animals. These results show that this model can be used as a bioassay to validate reprocessing procedures for surgical instruments. At the time of submission of this article, only the group of hamsters incubated with wires reprocessed with an alkaline detergent, followed by sterilization with a modified cycle in a hydrogen peroxide gas plasma sterilizer (4 injections), showed no clinical signs of disease and remained alive. Two animals from the group receiving sodium hydroxide followed by autoclaving (at 134 degrees C for 18 minutes) died. Furthermore, the tested enzymatic cleaning agent seemed to have no positive effect.

  13. 30 CFR 57.5005 - Control of exposure to airborne contaminants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Underground § 57.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention of contamination, removal by exhaust...

  14. MSFC Skylab contamination control systems mission evaluation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Cluster external contamination control evaluation was made throughout the Skylab Mission. This evaluation indicated that contamination control measures instigated during the design, development, and operational phases of this program were adequate to reduce the general contamination environment external to the Cluster below the threshold senstivity levels for experiments and affected subsystems. Launch and orbit contamination control features included eliminating certain vents, rerouting vents for minimum contamination impact, establishing filters, incorporating materials with minimum outgassing characteristics and developing operational constraints and mission rules to minimize contamination effects. Prior to the launch of Skylab, contamination control math models were developed which were used to predict Cluster surface deposition and background brightness levels throughout the mission. The report summarizes the Skylab system and experiment contamination control evaluation. The Cluster systems and experiments evaluated include Induced Atmosphere, Corollary and ATM Experiments, Thermal Control Surfaces, Solar Array Systems, Windows and Star Tracker.

  15. Planetary quarantine impacts on probe design

    NASA Technical Reports Server (NTRS)

    Defrees, R. E.

    1974-01-01

    The design of space probes for Saturn and Uranus and the effects of imposing planetary quarantine constraints on that design are discussed. Special attention was given to probability of contamination and procedures for eliminating contamination including dry heat.

  16. Contamination risk of stable isotope samples during milling.

    PubMed

    Isaac-Renton, M; Schneider, L; Treydte, K

    2016-07-15

    Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Chlorine inactivation of fungal spores on cereal grains.

    PubMed

    Andrews, S; Pardoel, D; Harun, A; Treloar, T

    1997-04-01

    Although 0.4% chlorine for 2 min has been recommended for surface disinfection of food samples before direct plating for fungal enumeration, this procedure may not be adequate for highly contaminated products. The effectiveness of a range of chlorine solutions was investigated using barley samples artificially contaminated with four different concentrations of Aspergillus flavus. A. niger, A. ochraceus, Eurotium repens, Penicillium brevicompactum P. chrysogenum and Cladosporium cladosporioides. At initial contamination levels greater than 10(4)/g, 0.4% chlorine did not inactivate sufficient spores to produce less than 20% contamination. Of the test fungi, ascospores of E. repens were the most resistant to chlorine inactivation, whereas the conidia of C. cladosporioides were the most sensitive. Rinsing the samples with 70% ethanol improved the effectiveness of the recommended surface disinfection procedure. However, some ethanol appears to permeate into the grains and may inactivate sensitive internal fungi, although a minimal effect only was observed on wheat infected with Alternaria.

  18. Production and engineering methods for CARB: TEK (trade name) batteries in fork lift trucks

    NASA Astrophysics Data System (ADS)

    Schaefer, J. C.

    1975-03-01

    The purpose of this program is to develop the manufacturing technology of the Carb Tek molten salt Li/Cl battery to the prototype level. This purpose is being accomplished by actually constructing cells on a pilot line, optimizing process steps, establishing quality control procedures, and engineering appropriate changes. The majority of the cell work is performed in a controlled argon atmosphere. Results show that the carbon selected for the cell cathode can develop the required 5 Whr/cubic inch even when damaged by stress cracks. Anode contamination and fabrication problems have been reduced by a new alloying technique. Cell yields are dependent on weld quality.

  19. Toxicological assessment of aquatic ecosystems: application to watercraft contaminants in shallow water environments

    USGS Publications Warehouse

    Winger, P.V.; Kemmish, Michael J.

    2002-01-01

    Recreational boating and personal watercraft use have the potential to adversely impact shallow water systems through contaminant release and physical disturbance of bottom sediments. These nearshore areas are often already degraded by surface runoff, municipal and industrial effluents, and other anthropogenic activities. For proper management, information is needed on the level of contamination and environmental quality of these systems. A number of field and laboratory procedures can be used to provide this much needed information. Contaminants, such as metals, pesticides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons, entering aquatic environments generally attach to particulate matter that eventually settles and becomes incorporated into the bottom sediments. Because bottom sediments serve as a sink and as a source for contaminants, environmental assessments generally focus on this matrix. While contaminant residues in sediments and sediment pore waters can reflect environmental quality, characteristics of sediment (redox potential, sediment/pore-water chemistry, acid volatile sulfides, percent organic matter, and sediment particle size) influence their bioavailability and make interpretation of environmental significance difficult. Comparisons of contaminant concentrations in pore water (interstitial water) and sediment with water quality criteria and sediment quality guidelines, respectively, can provide insight into potential biological effects. Laboratory bioaccumulation studies and residue concentrations in resident or caged biota also yield information on potential biological impacts. The usefulness of these measurements may increase as data are developed relating in-situ concentrations, tissue residue levels, and biological responses. Exposure of test organisms in situ or to field-collected sediment and pore water are additional procedures that can be used to assess the biological effects of contaminants. A battery of tests using multi-species and/or various life stages with different sensitivities to contaminants may offer a more conservative assessment of toxicity than single species testing. Using a ?weight of evidence? approach, the Sediment Quality Trial produces a robust evaluation of habitat quality and includes a measure of contaminant concentrations in the sediment, an assessment of sediment/pore-water toxicity to laboratory animals, and an evaluation of in situ biological assemblages. Field and laboratory procedures are available that can be used to ascertain habitat quality, identify contaminants causing environmental degradation and delineate aquatic systems requiring mitigation of protective efforts. These studies provide the scientific data that are integral to developing an environmental risk assessment of contaminants from watercraft use in shallow water systems.

  20. 32 CFR 218.2 - General procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GUIDANCE FOR THE DETERMINATION AND REPORTING OF NUCLEAR RADIATION DOSE FOR DOD PARTICIPANTS IN THE ATMOSPHERIC NUCLEAR TEST PROGRAM (1945-1962) § 218.2 General procedures. The following procedures govern the... exposure. (c) Qualitatively assess the radiation environment in order to delineate contaminated areas. If...

  1. 32 CFR 218.2 - General procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... GUIDANCE FOR THE DETERMINATION AND REPORTING OF NUCLEAR RADIATION DOSE FOR DOD PARTICIPANTS IN THE ATMOSPHERIC NUCLEAR TEST PROGRAM (1945-1962) § 218.2 General procedures. The following procedures govern the... exposure. (c) Qualitatively assess the radiation environment in order to delineate contaminated areas. If...

  2. 32 CFR 218.2 - General procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GUIDANCE FOR THE DETERMINATION AND REPORTING OF NUCLEAR RADIATION DOSE FOR DOD PARTICIPANTS IN THE ATMOSPHERIC NUCLEAR TEST PROGRAM (1945-1962) § 218.2 General procedures. The following procedures govern the... exposure. (c) Qualitatively assess the radiation environment in order to delineate contaminated areas. If...

  3. 32 CFR 218.2 - General procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... GUIDANCE FOR THE DETERMINATION AND REPORTING OF NUCLEAR RADIATION DOSE FOR DOD PARTICIPANTS IN THE ATMOSPHERIC NUCLEAR TEST PROGRAM (1945-1962) § 218.2 General procedures. The following procedures govern the... exposure. (c) Qualitatively assess the radiation environment in order to delineate contaminated areas. If...

  4. Method for distinctive estimation of stored acidity forms in acid mine wastes.

    PubMed

    Li, Jun; Kawashima, Nobuyuki; Fan, Rong; Schumann, Russell C; Gerson, Andrea R; Smart, Roger St C

    2014-10-07

    Jarosites and schwertmannite can be formed in the unsaturated oxidation zone of sulfide-containing mine waste rock and tailings together with ferrihydrite and goethite. They are also widely found in process wastes from electrometallurgical smelting and metal bioleaching and within drained coastal lowland soils (acid-sulfate soils). These secondary minerals can temporarily store acidity and metals or remove and immobilize contaminants through adsorption, coprecipitation, or structural incorporation, but release both acidity and toxic metals at pH above about 4. Therefore, they have significant relevance to environmental mineralogy through their role in controlling pollutant concentrations and dynamics in contaminated aqueous environments. Most importantly, they have widely different acid release rates at different pHs and strongly affect drainage water acidity dynamics. A procedure for estimation of the amounts of these different forms of nonsulfide stored acidity in mining wastes is required in order to predict acid release rates at any pH. A four-step extraction procedure to quantify jarosite and schwertmannite separately with various soluble sulfate salts has been developed and validated. Corrections to acid potentials and estimation of acid release rates can be reliably based on this method.

  5. Adenosine Triphosphate Quantification Correlates Poorly with Microbial Contamination of Duodenoscopes.

    PubMed

    Olafsdottir, Lovisa B; Wright, Sharon B; Smithey, Anne; Heroux, Riley; Hirsch, Elizabeth B; Chen, Alice; Lane, Benjamin; Sawhney, Mandeep S; Snyder, Graham M

    2017-06-01

    OBJECTIVE The aim of this study was to quantify the correlation between adenosine triphosphate (ATP) measurements and bacterial cultures from duodenoscopes for evaluation of contamination following high-level disinfection. DESIGN Duodenoscopes used for any intended endoscopic retrograde cholangiopancreatography (ERCP) procedure were included. Microbiologic and ATP data were collected concomitantly and in the same manner from ERCP duodenoscopes. SETTING A high-volume endoscopy unit at a tertiary referral acute-care facility. METHODS Duodenoscopes were sampled for ATP and bacterial contamination in a contemporaneous and highly standardized fashion using a "flush-brush-flush" method for the working channel (WC) and a dry flocked swab for the elevator mechanism (EM). Specimens were processed for any aerobic bacterial growth (colony-forming units, CFU). Growth of CFU>0 and ATP relative light unit (RLU)>0 was considered a contaminated result. Frequency of discord between among WC and EM measurements were calculated using 2×2 contingency tables. The Spearman correlation coefficient was used to calculate the relatedness of bacterial contamination and ATP as continuous measurements. RESULTS The Spearman correlation coefficient did not demonstrate significant relatedness between ATP and CFU for either a WC or EM site. Among 390 duodenoscope sampling events, ATP and CFU assessments of contamination were discordant in 82 of 390 WC measurements (21%) and 331 of 390 of EM measurements (84.9%). The EM was frequently and markedly positive by ATP measurement. CONCLUSION ATP measurements correlate poorly with a microbiologic standard assessing duodenoscope contamination, particularly for EM sampling. ATP may reflect biological material other than nonviable aerobic bacteria and may not serve as an adequate marker of bacterial contamination. Infect Control Hosp Epidemiol 2017;38:678-684.

  6. Guidelines for Neurotoxicity Risk Assessment

    EPA Pesticide Factsheets

    These Guidelines set forth principles and procedures to guide EPA scientists in evaluating environmental contaminants that may pose neurotoxic risks, and inform Agency decision makers and the public about these procedures.

  7. Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.

    2004-01-01

    Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST &om contamination and the instruments from self-contamination.

  8. Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.

    2004-01-01

    Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST from contamination and the instruments from self-contamination.

  9. Controlling systematic perioperative anaerobic contamination during sinus-lift procedures by using metronidazole: an innovative approach.

    PubMed

    Choukroun, Joseph; Simonpieri, Alain; Del Corso, Marco; Mazor, Ziv; Sammartino, Gilberto; Dohan Ehrenfest, David M

    2008-09-01

    Analysis of tomodensitometric controls following sinus grafts clearly demonstrates a quite systematic lack of homogeneity. Sinus contamination by anaerobic bacteria seems almost unavoidable during bone graft surgery, and this problem may jeopardize the healing process. The aim of this study was to characterize in a systematic way the nonhomogeneities observed at 1, 2, or 3 months postsurgery within allogenous sinus grafts, and to assess the possible influence of a 0.5% sterile solution of metronidazole incorporated in the sinus bone graft. This clinical study was conducted on 72 patients treated with single or bilateral sinus-lifts: 94 sinus elevations performed with freeze-dried bone allograft (Phoenix, TBF, Mions, France), with (test group) or without (control group) metronidazole. In the test group, each bone graft was hydrated with 2 mL of a 0.5% metronidazole solution, i.e., only 10 mg of metronidazole. All the patients went through a first presurgical computerized tomography (CT)-scan followed by a second scan performed at 1, 2, or 3 months postsurgery (which was used as the preimplant reference scan). For 11 patients, 2 postsurgical CT-scans were performed respectively at 10 days and 2 months. Using an arbitrary gray scale (Arbitrary Densitometric Unit) which functions according to the Hounsfield unit principle, the degree of radiographic homogeneity of the grafts was established. Density scattering provides some information on the homogeneity or nonhomogeneity of the bone graft. The 12 grafts performed without metronidazole show significant nonhomogeneities at 1, 2, or 3 months. Moreover, when a CT-scan is performed during the first postoperative days (at 10 days), the presence of air bubbles in the graft is confirmed. The tomodensitometric aspects of all grafts treated with metronidazole in this series are absolutely identical: they show a high degree of homogeneity. Sixty-three cases (76.8%) are homogeneous, and 19 cases (23.2%) are significantly homogeneous. The time at which the control scan is performed (10 days, 1, 2, or 3 months) does not seem to influence significantly the degree of homogeneity assessed. In the control group, some inflammatory events associated with facial oedema were observed in 25% of the cases. In the test group, no such event was recorded for the 82 sinus-lifts treated with metronidazole. A possible correlation may exist between the occurrence of non homogeneities within the bone grafts and the anaerobic bacterial contamination. The local use of a very small quantity of metronidazole (equivalent to only 1/20 of a common 200 mg oral tablet) could provide more security when performing sinus-lift procedures and an improved quality of the graft. This protocol should not be considered as an antibiotherapy, but only as way to limit the initial contamination of bone graft.

  10. Microbiological contamination in digital radiography: evaluation at the radiology clinic of an educational institution.

    PubMed

    Malta, Cristiana P; Damasceno, Naiana Nl; Ribeiro, Rosangela A; Silva, Carolina Sf; Devito, Karina L

    2016-12-01

    The aim of this study was to evaluate the contamination rate of intra and extraoral digital X ray equipment in a dental radiology clinic at a public educational institution. Samples were collected on three different days, at two times in the day: in the morning, before attending patients, and at the end of the day, after appointment hours and before cleaning and disinfection procedures. Samples were collected from the periapical X-ray machine (tube head, positioning device, control panel and activator button), the panoramic X- ray machine (temporal support, bite block, control panel and activator button), the intraoral digital system (sensor), and the digital system computers (keyboard and mouse). The samples were seeded in different culture media, incubated, and colony forming units (CFU/mL) counted. Biochemical tests were performed for suspected colonies of Staphylococcus, Streptococcus and Gramnegative bacilli (GNB). Fungi were visually differentiated into filamentous fungi and yeasts. The results indicated the growth of fungi and Staphylococcus fromall sampling locations. GNB growth was observed from all sites sampled from the intraoral X-ray equipment. On the panoramic unit, GNB growth was observed in samples from activator button, keyboard and mouse. In general, a higher number of CFU/mL was present before use. It can be concluded that more stringent protocols are needed to control infection and prevent X-ray exams from acting as vehicle for cross contamination. Sociedad Argentina de Investigación Odontológica.

  11. Testing contamination source identification methods for water distribution networks

    DOE PAGES

    Seth, Arpan; Klise, Katherine A.; Siirola, John D.; ...

    2016-04-01

    In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections,more » and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. These SI methods and a testing framework that includes the test cases and analysis tools presented in this paper have been integrated into EPA’s Water Security Toolkit (WST), a suite of software tools to help researchers and others in the water industry evaluate and plan various response strategies in case of a contamination incident. Lastly, a set of recommendations are made for users to consider when working with different categories of SI methods.« less

  12. Control of human pathogenic Yersinia enterocolitica in minced meat: Comparative analysis of different interventions using a risk assessment approach.

    PubMed

    Van Damme, I; De Zutter, L; Jacxsens, L; Nauta, M J

    2017-06-01

    This study aimed to evaluate the effect of different processing scenarios along the farm-to-fork chain on the contamination of minced pork with human pathogenic Y. enterocolitica. A modular process risk model (MPRM) was used to perform the assessment of the concentrations of pathogenic Y. enterocolitica in minced meat produced in industrial meat processing plants. The model described the production of minced pork starting from the contamination of pig carcasses with pathogenic Y. enterocolitica just before chilling. The endpoints of the assessment were (i) the proportion of 0.5 kg minced meat packages that contained pathogenic Y. enterocolitica and (ii) the proportion of 0.5 kg minced meat packages that contained more than 10³ pathogenic Y. enterocolitica at the end of storage, just before consumption of raw pork or preparation. Comparing alternative scenarios to the baseline model showed that the initial contamination and different decontamination procedures of carcasses have an important effect on the proportion of highly contaminated minced meat packages at the end of storage. The addition of pork cheeks and minimal quantities of tonsillar tissue into minced meat also had a large effect on the endpoint estimate. Finally, storage time and temperature at consumer level strongly influenced the number of highly contaminated packages. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Enhanced organic contaminants accumulation in crops: Mechanisms, interactions with engineered nanomaterials in soil.

    PubMed

    Wu, Xiang; Wang, Wei; Zhu, Lizhong

    2018-05-02

    The mechanism of enhanced accumulation of organic contaminants in crops with engineered nanomaterials (ENMs) were investigated by co-exposure of crops (Ipomoea aquatica Forsk (Swamp morning-glory), Cucumis sativus L. (cucumber), Zea mays L. (corn), Spinacia oleracea L. (spinach) and Cucurbita moschata (pumpkin))to a range of chemicals (polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides (OCPs) and polybrominated diphenyl ether (PBDE)) and ENMs (TiO 2 , Ag, Al 2 O 3 , graphene, carbon nanotubes (CNTs)) in soil. Induced by 50 mg kg -1 graphene co-exposure, the increase range of BDE-209, BaP, p,p'-DDE, HCB, PYR, FLU, ANT, and PHEN in the plants were increased in the range of 7.51-36.42, 5.69-32.77, 7.09-59.43, 11.61-66.73, 4.58-57.71, 5.79-109.07, 12.85-109.76, and15.57-127.75 ng g -1 , respectively. The contaminants in ENMs-spiked and control soils were separated into bioavailable, bound and residual fractions using a sequential ultrasonic extraction procedure (SUEP) to investigate the mechanism of the enhanced accumulation. The bioavailable fraction in spiked soils showed no significant difference (p > 0.05) from that in the control, while the bound fraction increased in equal proportion (p > 0.05) to the reduction in the residual fraction. These results implied that ENMs can competitively adsorbed the bound of organic contaminants from soil and co-transferred into crops, followed by a portion of the residual fraction transferred to the bound fraction to maintain the balance of different fractions in soils. The mass balance was all higher than 98.5%, indicating the portion of degraded contaminants was less than 1.5%. These findings could expand our knowledge about the organic contaminants accumulation enhancement in crops with ENMs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. METALS IN GROUND WATER: SAMPLING ARTIFACTS AND REPRODUCIBILITY

    EPA Science Inventory

    Field studies evaluated sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. esearch at three different metal-contaminated sites has shown that 0.45 tm filtration has not removed potentially mobile ...

  15. A new procedure for treatment of oily slurry using geotextile filters.

    PubMed

    Mendonça, M B; Cammarota, M C; Freire, D D C; Ehrlich, M

    2004-07-05

    A new procedure to mitigate the environmental impacts and reduce the cost of disposal of oil slurry is present in this paper. Waste from the petroleum industry has a high environmental impact. Systems for oil-water separation have been used to mitigate the contamination potential of these types of effluents. At the outlet of these systems, the oil is skimmed-off the surface, while the slurry is removed from the base. Due to the high concentration of contaminants, the disposal of this slurry is an environmentally hazardous practice. Usually this type of waste is disposed of in tanks or landfills after removal from the industrial plant. Basically, the proposed procedure utilizes drying beds with geotextile filters to both reduce the water content in the slurry and obtain a less contaminated effluent. Laboratory tests were carried out to simulate the drying system. Four types of filters were analyzed: two non-woven geotextiles, one woven geotextile, and a sand filter.

  16. Danger ideation reduction therapy (DIRT) for obsessive-compulsive washers. A controlled trial.

    PubMed

    Jones, M K; Menzies, R G

    1998-10-01

    Twenty-one OCD sufferers with washing/contamination concerns took part in a controlled treatment trial at the Anxiety Disorders Clinic, University of Sydney. Eleven of the subjects received danger ideation reduction therapy (DIRT) over eight, 1 h weekly group sessions conducted by the second author. Ten subjects were placed on a wait list and did not receive DIRT or any other treatment. DIRT procedures were solely directed at decreasing danger-related expectancies concerning contamination and did not include exposure, response prevention or behavioral experiments. Components of DIRT include attentional focusing, filmed interviews, corrective information, cognitive restructuring, expert testimony, microbiological experiments and a probability of catastrophe assessment task. All subjects were assessed at pre-treatment, post-treatment and three-month follow-up using the Maudsley Obsessional-Compulsive Inventory, Leyton Obsessionality Inventory, Beck Depression Inventory and a Self Rating of Severity Scale. Changes from pre-treatment to after treatment (post-treatment and follow-up scores averaged) were significantly greater in the DIRT condition than in the control condition for all measures. No significant differences were obtained between groups on post-treatment to follow-up change on any measure. The implications of these findings for theoretical models of OCD and its management are discussed.

  17. Zero-tolerance for faecal contamination of carcasses as a tool in the control of O157 VTEC infections.

    PubMed

    Heuvelink, A E; Roessink, G L; Bosboom, K; de Boer, E

    2001-05-21

    The Dutch government, the meat producers organisation and the meat industry have recognised O157 VTEC as an important public health hazard, and agreed on the necessity to improve the hygiene in Dutch cattle- and calf-slaughtering establishments. This paper reports activities within a national action programme to achieve this objective, "Zero-tolerance for faecal contamination during slaughter of cattle and calves". The study included inspection of hygienic performances in slaughterhouses, and visual and microbiological (aerobic plate counts, Enterobacteriaceae counts and O157 VTEC presence/absence on visually clean cattle and calf carcasses) assessment of carcass cleanliness. Initial studies concluded that the hygienic performances in the Dutch cattle and calf slaughterhouses should be immediately improved. In 52% of the slaughterhouses inspected, carcasses were observed to be contaminated with hide, hair or faeces. Around 45% of the slaughterhouses had constructural deficiencies likely to lead to structural cross-contamination of carcasses, by direct carcass-carcass contact, or by indirect contacts with floors, walls or steps. In 39% of the slaughterhouses, cleaning and disinfection procedures were inadequate. Visual inspection of chilled carcasses found that in 11 of the 27 slaughterhouses visited, more than 10% of the carcasses were visibly contaminated. In 6 of the 27 slaughterhouses visited, more than 50% of the carcasses inspected were visibly contaminated. Microbiological analysis of visually clean carcasses noted contamination levels similar to those reported from other countries. O157 VTEC were not isolated during this study. Circulation of these findings lead to increased efforts by all parties to fulfil the requirements of the statutory "Zero-tolerance" programme. A follow-up study noted a significant decrease in the proportions of faecally contaminated carcasses, i.e., 7% of chilled carcasses were visibly contaminated with faeces, as opposed to 22% contamination during the initial study. The follow-up study also noted a greater awareness of the importance of good hygienic practices among slaughterhouse personnel and government meat inspectors.

  18. Design/Use of the Remotely Operated Bakeout Box Shutter (ROBBS)

    NASA Technical Reports Server (NTRS)

    Ottens, Brian P.

    1999-01-01

    A thermal vacuum box bakeout and certification allows orbital payloads to be cleaned and certified when the background TQCM measurements (a measure of how much molecular contamination is on a payload or chamber) are unacceptable or unmanageable in the standard thermal vacuum chamber. The box bakeout procedure is usually performed in 4 steps: bakeout the box, certify the box, bake out the payload, and finally certify the payload. In the procedure's current setup, the contaminant conduction hole ("lid") is initially open and a vacuum chamber break must occur between the bakeout and certification phases to close the box from the vacuum chamber. This exposure is necessary to allow the outgassed contaminants to escape the box's volume rapidly during bakeout phase, but payload certification isn't usually performed while the lid is still open, because it exposes the payload, TQCM, and box volume to chamber contaminants. The Remotely Operated Bakeout Box Shutter (ROBBS) is a new facility design and will allow the remote closure of the contamination hole while the chamber is still under vacuum, and with little or no time to do so.

  19. Real-time detection of organic contamination events in water distribution systems by principal components analysis of ultraviolet spectral data.

    PubMed

    Zhang, Jian; Hou, Dibo; Wang, Ke; Huang, Pingjie; Zhang, Guangxin; Loáiciga, Hugo

    2017-05-01

    The detection of organic contaminants in water distribution systems is essential to protect public health from potential harmful compounds resulting from accidental spills or intentional releases. Existing methods for detecting organic contaminants are based on quantitative analyses such as chemical testing and gas/liquid chromatography, which are time- and reagent-consuming and involve costly maintenance. This study proposes a novel procedure based on discrete wavelet transform and principal component analysis for detecting organic contamination events from ultraviolet spectral data. Firstly, the spectrum of each observation is transformed using discrete wavelet with a coiflet mother wavelet to capture the abrupt change along the wavelength. Principal component analysis is then employed to approximate the spectra based on capture and fusion features. The significant value of Hotelling's T 2 statistics is calculated and used to detect outliers. An alarm of contamination event is triggered by sequential Bayesian analysis when the outliers appear continuously in several observations. The effectiveness of the proposed procedure is tested on-line using a pilot-scale setup and experimental data.

  20. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments: Standard Operating Procedure for PE Analysis

    DTIC Science & Technology

    2012-12-01

    4.5 Food-grade aluminum foil 4.6 Stainless steel forceps 4.7 Single-edge razor blades 4.8 Teflon (or similar non-contaminating material) cutting...handling PE to avoid cross-contaminating the PE. 6.3 Methylene chloride (pesticide grade) rinsed, stainless steel forceps and scissors are used...3.1 PE is susceptible to contamination from atmospheric and surfaces, and so it must be handled using clean techniques. 3.2 While the formation of

  1. A Procedure for the supercritical fluid extraction of coal samples, with subsequent analysis of extracted hydrocarbons

    USGS Publications Warehouse

    Kolak, Jonathan J.

    2006-01-01

    Introduction: This report provides a detailed, step-by-step procedure for conducting extractions with supercritical carbon dioxide (CO2) using the ISCO SFX220 supercritical fluid extraction system. Protocols for the subsequent separation and analysis of extracted hydrocarbons are also included in this report. These procedures were developed under the auspices of the project 'Assessment of Geologic Reservoirs for Carbon Dioxide Sequestration' (see http://pubs.usgs.gov/fs/fs026-03/fs026-03.pdf) to investigate possible environmental ramifications associated with CO2 storage (sequestration) in geologic reservoirs, such as deep (~1 km below land surface) coal beds. Supercritical CO2 has been used previously to extract contaminants from geologic matrices. Pressure-temperature conditions within deep coal beds may render CO2 supercritical. In this context, the ability of supercritical CO2 to extract contaminants from geologic materials may serve to mobilize noxious compounds from coal, possibly complicating storage efforts. There currently exists little information on the physicochemical interactions between supercritical CO2 and coal in this setting. The procedures described herein were developed to improve the understanding of these interactions and provide insight into the fate of CO2 and contaminants during simulated CO2 injections.

  2. PHYSIOLOGICALLY BASED EXTRACTION PROCEDURE: COMPARISON OF FIVE FLUIDS

    EPA Science Inventory

    Traditionally, the performance of soil remediation technologies has been evaluated based on the total amount of extractable contaminants. However, some have argued that remedial treatments may alter the bioavailability as well as the mass of contaminants. For example, it has been...

  3. Sampling procedure for lake or stream surface water chemistry

    Treesearch

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  4. COLLOIDAL-FACILITATED TRANSPORT OF INORGANIC CONTAMINANTS IN GROUND WATER: PART I. SAMPLING CONSIDERATIONS

    EPA Science Inventory

    Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen,...

  5. Identification and Removal of Contaminant Sequences From Ribosomal Gene Databases: Lessons From the Census of Deep Life

    PubMed Central

    Sheik, Cody S.; Reese, Brandi Kiel; Twing, Katrina I.; Sylvan, Jason B.; Grim, Sharon L.; Schrenk, Matthew O.; Sogin, Mitchell L.; Colwell, Frederick S.

    2018-01-01

    Earth’s subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium, Aquabacterium, Ralstonia, and Acinetobacter. While the top five most frequently observed genera were Pseudomonas, Propionibacterium, Acinetobacter, Ralstonia, and Sphingomonas. The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ∼27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth’s deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset. PMID:29780369

  6. Identification and Removal of Contaminant Sequences From Ribosomal Gene Databases: Lessons From the Census of Deep Life.

    PubMed

    Sheik, Cody S; Reese, Brandi Kiel; Twing, Katrina I; Sylvan, Jason B; Grim, Sharon L; Schrenk, Matthew O; Sogin, Mitchell L; Colwell, Frederick S

    2018-01-01

    Earth's subsurface environment is one of the largest, yet least studied, biomes on Earth, and many questions remain regarding what microorganisms are indigenous to the subsurface. Through the activity of the Census of Deep Life (CoDL) and the Deep Carbon Observatory, an open access 16S ribosomal RNA gene sequence database from diverse subsurface environments has been compiled. However, due to low quantities of biomass in the deep subsurface, the potential for incorporation of contaminants from reagents used during sample collection, processing, and/or sequencing is high. Thus, to understand the ecology of subsurface microorganisms (i.e., the distribution, richness, or survival), it is necessary to minimize, identify, and remove contaminant sequences that will skew the relative abundances of all taxa in the sample. In this meta-analysis, we identify putative contaminants associated with the CoDL dataset, recommend best practices for removing contaminants from samples, and propose a series of best practices for subsurface microbiology sampling. The most abundant putative contaminant genera observed, independent of evenness across samples, were Propionibacterium , Aquabacterium , Ralstonia , and Acinetobacter . While the top five most frequently observed genera were Pseudomonas , Propionibacterium , Acinetobacter , Ralstonia , and Sphingomonas . The majority of the most frequently observed genera (high evenness) were associated with reagent or potential human contamination. Additionally, in DNA extraction blanks, we observed potential archaeal contaminants, including methanogens, which have not been discussed in previous contamination studies. Such contaminants would directly affect the interpretation of subsurface molecular studies, as methanogenesis is an important subsurface biogeochemical process. Utilizing previously identified contaminant genera, we found that ∼27% of the total dataset were identified as contaminant sequences that likely originate from DNA extraction and DNA cleanup methods. Thus, controls must be taken at every step of the collection and processing procedure when working with low biomass environments such as, but not limited to, portions of Earth's deep subsurface. Taken together, we stress that the CoDL dataset is an incredible resource for the broader research community interested in subsurface life, and steps to remove contamination derived sequences must be taken prior to using this dataset.

  7. Sample Collection Procedures and Strategies

    EPA Pesticide Factsheets

    Individuals responsible for collecting environmental and building material samples following a contamination incident, can use these procedures to plan for and/or collect samples for analysis using the analytical methods listed in EPA's SAM

  8. Project 57 Air Monitoring Report: January 1 through December 31, 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A.; Nikolich, George; Shadel, Craig

    On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley northeast of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DOD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a non-nuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve,more » 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Various radiological surveys were performed in the area and in 2007, the DOE expanded the demarked Contamination Area (CA) by posting signs 200 to 400 ft (60 to 120 m) outside of the original fence.« less

  9. Traveltime and dispersion in the Shenandoah River and its tributaries, Waynesboro, Virginia, to Harpers Ferry, West Virginia

    USGS Publications Warehouse

    Taylor, K.R.; James, R.W.; Helinsky, B.M.

    1986-01-01

    Two traveltime and dispersion measurements using rhodamin dye were conducted on a 178-mile reach of the Shenandoah River between Waynesboro, Virginia, and Harpers Ferry, West Virginia. The flows during the two measurements were at approximately the 85% and 45% flow durations. The two sets of data were used to develop a generalized procedure for predicting traveltimes and downstream concentrations resulting from spillage of water soluble substances at any point along the river reach studied. The procedure can be used to calculate traveltime and concentration data for almost any spillage that occurs during relatively steady flow between a 40% to 95% flow duration. Based on an analogy between the general shape of a time concentration curve and a scalene triangle, the procedures can be used on long river reaches to approximate the conservative time concentration curve for instantaneous spills of contaminants. The triangular approximation technique can be combined with a superposition technique to predict the approximate, conservative time concentration curve for constant rate and variable rate injections of contaminants. The procedure was applied to a hypothetical situation in which 5,000 pounds of contaminants is spilled instantaneously at Island Ford, Virginia. The times required for the leading edge, the peak concentration, and the trailing edge of the contaminant cloud to reach the water intake at Front Royal, Virginia (85 miles downstream), are 234,280, and 340 hrs, respectively, for a flow at an 80% flow duration. The conservative peak concentration would be approximately 940 micrograms/L at Front Royal. The procedures developed cannot be depended upon when a significant hydraulic wave or other unsteady flow condition exists in the flow system or when the spilled material floats or is immiscible in water. (Author 's abstract)

  10. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments 1

    PubMed Central

    de Camargo, Tamara Carolina; Graziano, Kazuko Uchikawa; Almeida, Alda Graciele Claudio dos Santos; Suzuki, Karina; da Silva, Cely Barreto; Pinto, Flávia Morais Gomes

    2016-01-01

    ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument. PMID:27878222

  11. [Environmental hygiene of the surgery suites for the control of surgical wound infection: Italian legislation and international guidelines].

    PubMed

    Charrier, L; Castella, A; Di Legami, V; Pastorino, F; Farina, E C; Argentero, P A; Zotti, C M

    2006-01-01

    Aim of the study is to describe the application of surgical site infection (SSI) control procedures in general surgery operating rooms of Piedmont region hospitals. A specific data collection form was designed to record information. 54 questionnaires were compiled. Piedmont legislation related to operating rooms' equipment is obeyed in more than 90% of hospitals. Nevertheless, there are some critical aspects than could be risk factors for SSI or that are not useful in order to prevent them: use of UV radiation (11.3%), use of tacky mats at the entrance of the operating room (5.7%), special cleaning of operating rooms after contaminated or dirty operations (73.6%) and routine environmental sampling (10%) that is strongly recommended by ISPESL guideline in disagreement with international recommendations. Steam autoclave is used for surgical instruments sterilization by 100% of hospitals, but only 50% of them performs an annual validation of both autoclave performance and sterilization procedures. The study gave useful information in order to promote some structural modifications and personnel education for efficacious SSI prevention and control.

  12. Correlation of the Hubble Space Telescope (HST) Space Telescope Imaging Spectrometer (STIS) On-Orbit Data with Pre-launch Predictions and Ground Contamination Controls

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.

    2003-01-01

    The Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) was deployed on-orbit in February 1997. The contamination program for STIS was stringently controlled as the five-year end-of-life deposition was set at 158, per optical element. Contamination was controlled through materials selection, extensive vacuum outgassing certifications, cleaning techniques, and environmental controls. In addition to ground contamination controls, on-orbit contamination controls were implemented for both the HST servicing mission activities and early post-servicing mission checkout. The extensive contamination control program will be discussed and the STIS on-orbit data will be correlated with the prelaunch analytical predictions.

  13. Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures.

    PubMed

    Ferrario, J; Byrne, C; Dupuy, A E

    1997-06-01

    The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

  14. Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

    NASA Technical Reports Server (NTRS)

    Ferrario, J.; Byrne, C.; Dupuy, A. E. Jr

    1997-01-01

    The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

  15. Transrectal rigid-hybrid NOTES cholecystectomy can be performed without peritoneal contamination: a controlled porcine survival study.

    PubMed

    Müller, Philip C; Senft, Jonas D; Gath, Philip; Steinemann, Daniel C; Nickel, Felix; Billeter, Adrian T; Müller-Stich, Beat P; Linke, Georg R

    2018-01-01

    The risk of infectious complications due to peritoneal contamination is a major concern and inhibits the widespread use of transrectal NOTES. A standardized rectal washout with a reversible colon occlusion device in situ has previously shown potential in reducing peritoneal contamination. The aim of this study was to compare the peritoneal contamination rate and inflammatory reaction for transrectal cholecystectomy after ideal rectal preparation (trCCE) and standard laparoscopic cholecystectomy (lapCCE) in a porcine survival experiment. Twenty pigs were randomized to trCCE (n = 10) or lapCCE (n = 10). Before trCCE, rectal washout was performed with saline solution. A colon occlusion device was then inserted and a second washout with povidone-iodine was performed. The perioperative course and the inflammatory reaction (leukocytes, C-reactive protein) were compared. At necropsy, 14 days after surgery the abdominal cavity was screened for infectious complications and peritoneal swabs were obtained for comparison of peritoneal contamination. Peritoneal contamination was lower after trCCE than after lapCCE (0/10 vs. 6/10; p = 0.003). No infectious complications were found at necropsy in either group and postoperative complications did not differ (p = 1.0). Immediately after the procedure, leukocytes were higher after lapCCE (17.0 ± 2.7 vs. 14.6 ± 2.3; p = 0.047). Leukocytes and C-reactive protein showed no difference in the further postoperative course. Intraoperative complications and total operation time (trCCE 114 ± 32 vs. 111 ± 27 min; p = 0.921) did not differ, but wound closure took longer for trCCE (31.5 ± 19 vs. 13 ± 5 min; p = 0.002). After standardized rectal washout with a colon occlusion device in situ, trCCE was associated without peritoneal contamination and without access-related infectious complications. Based on the findings of this study, a randomized controlled clinical study comparing clinical outcomes of trCCE with lapCCE should be conducted.

  16. ARSENIC SOLID-PHASE PARTITIONING IN REDUCING SEDIMENTS OF CONTAMINATED WETLAND

    EPA Science Inventory

    The geochemical partitioning of arsenic in organic-rich sediments from a contaminated wetland is examined using X-ray absorption spectroscopy and selective chemical extraction procedures, and evaluated in context to the anoxic diagenesis of iron and sulfur. The interaction betwe...

  17. An Exercise in Evaluating the Contamination Potential of Surface Impoundments.

    ERIC Educational Resources Information Center

    Tinker, John R., Jr.

    1982-01-01

    Outlines a laboratory procedure which enables students to evaluate the contamination potential of surface impoundments and apply basic principles of hydrogeology to the land disposal of waste material. Includes a list of materials needed and directions for the instructor. (Author/DC)

  18. Payload/orbiter contamination control requirement study

    NASA Technical Reports Server (NTRS)

    Bareiss, L. E.; Ress, E. B.

    1975-01-01

    The results of a contamination impact analysis upon the spacelab carrier and the spacelab carrier upon some of its potential payloads are presented. These results are based upon contamination computer modeling techniques developed to predict the induced environment for spacelab and to provide the basis for evaluation of the predicted environment against the current on orbit contamination control criteria as specified for payloads. Those spacelab carrier contamination sources evaluated against the stated contamination control criteria were outgassing/offgassing of the major nonmetallic thermal control coating of the spacelab carriers, spacelab core and experiment module and tunnel cabin atmosphere leakage, avionics bay vent, spacelab condensate vent, random particulate sloughing, and the return flux of the molecular content of these sources from the gas-gas interactions with the ambient orbital environment. It is indicated that the spacelab carrier can meet the intent of the contamination control criteria through incorporating known contamination control practices.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seth, Arpan; Klise, Katherine A.; Siirola, John D.

    In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections,more » and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. These SI methods and a testing framework that includes the test cases and analysis tools presented in this paper have been integrated into EPA’s Water Security Toolkit (WST), a suite of software tools to help researchers and others in the water industry evaluate and plan various response strategies in case of a contamination incident. Lastly, a set of recommendations are made for users to consider when working with different categories of SI methods.« less

  20. What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit.

    PubMed

    Russotto, Vincenzo; Cortegiani, Andrea; Fasciana, Teresa; Iozzo, Pasquale; Raineri, Santi Maurizio; Gregoretti, Cesare; Giammanco, Anna; Giarratano, Antonino

    2017-01-01

    Intensive care unit- (ICU-) acquired infections are a major health problem worldwide. Inanimate surfaces and equipment contamination may play a role in cross-transmission of pathogens and subsequent patient colonization or infection. Bacteria contaminate inanimate surfaces and equipment of the patient zone and healthcare area, generating a reservoir of potential pathogens, including multidrug resistant species. Traditional terminal cleaning methods have limitations. Indeed patients who receive a bed from prior patient carrying bacteria are exposed to an increased risk (odds ratio 2.13, 95% confidence intervals 1.62-2.81) of being colonized and potentially infected by the same bacterial species of the previous patient. Biofilm formation, even on dry surfaces, may play a role in reducing the efficacy of terminal cleaning procedures since it enables bacteria to survive in the environment for a long period and provides increased resistance to commonly used disinfectants. No-touch methods (e.g., UV-light, hydrogen peroxide vapour) are under investigation and further studies with patient-centred outcomes are needed, before considering them the standard of terminal cleaning in ICUs. Healthcare workers should be aware of the role of environmental contamination in the ICU and consider it in the broader perspective of infection control measures and stewardship initiatives.

  1. Can Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?

    PubMed Central

    Cristina, Maria Luisa; Spagnolo, Anna Maria; Sartini, Marina; Panatto, Donatella; Gasparini, Roberto; Orlando, Paolo; Ottria, Gianluca; Perdelli, Fernanda

    2012-01-01

    Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres. PMID:23285189

  2. Can particulate air sampling predict microbial load in operating theatres for arthroplasty?

    PubMed

    Cristina, Maria Luisa; Spagnolo, Anna Maria; Sartini, Marina; Panatto, Donatella; Gasparini, Roberto; Orlando, Paolo; Ottria, Gianluca; Perdelli, Fernanda

    2012-01-01

    Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m(3); the mean particle count was 4,194,569 no./m(3) for particles of diameter ≥0.5 µm and 13,519 no./m(3) for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.

  3. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    PubMed Central

    Iervolino, Matteo; Mancini, Benedetta; Cristino, Sandra

    2017-01-01

    The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H2O2) and silver salts (Ag+), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L. pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H2O2/Ag+ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease (p < 0.05) in Legionella concentration (1.77 Log cfu/L). The same trend was observed for P. aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health. PMID:28954435

  4. 30 CFR 56.5005 - Control of exposure to airborne contaminants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Air Quality and Physical Agents Air Quality § 56.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention...

  5. Multigeneration Cross Contamination of Mail with Bacillus Species Spores by Tumbling ▿

    PubMed Central

    Edmonds, Jason; Clark, Paul; Williams, Leslie; Lindquist, H. D. Alan; Martinez, Kenneth; Gardner, Warren; Shadomy, Sean; Hornsby-Myers, Jennifer

    2010-01-01

    In 2001, envelopes loaded with Bacillus anthracis spores were mailed to Senators Daschle and Leahy as well as to the New York Post and NBC News buildings. Additional letters may have been mailed to other news agencies because there was confirmed anthrax infection of employees at these locations. These events heightened the awareness of the lack of understanding of the mechanism(s) by which objects contaminated with a biological agent might spread disease. This understanding is crucial for the estimation of the potential for exposure to ensure the appropriate response in the event of future attacks. In this study, equipment to simulate interactions between envelopes and procedures to analyze the spread of spores from a “payload” envelope (i.e., loaded internally with a powdered spore preparation) onto neighboring envelopes were developed. Another process to determine whether an aerosol could be generated by opening contaminated envelopes was developed. Subsequent generations of contaminated envelopes originating from a single payload envelope showed a consistent two-log decrease in the number of spores transferred from one generation to the next. Opening a tertiary contaminated envelope resulted in an aerosol containing 103 B. anthracis spores. We developed a procedure for sampling contaminated letters by a nondestructive method aimed at providing information useful for consequence management while preserving the integrity of objects contaminated during the incident and preserving evidence for law enforcement agencies. PMID:20511424

  6. A critical look at the importance, prevalence and control of toxocariasis and the possibilities of immunological control.

    PubMed

    Barriga, O O

    1988-09-01

    The visceral infection of humans with Toxocara canis is particularly prevalent in children and may cause a variety of symptoms that commonly persist for 6-24 months. The ocular infection usually causes permanent loss of visual acuity. Human infection is acquired by ingestion of embryonated T. canis eggs with contaminated dirt. Review of recent reports indicates that patent T. canis infection is widely prevalent in the general population of dogs all over the world (3-81%) and results in a substantial contamination of the ground (0.3-87%). The results of sensitive and specific serological tests suggest that about 7% of the clinically healthy human population of the United States, about 5% of that of Canada, and about 4% of that in Great Britain is infected with the parasite. Control of transmission of the parasite to man is often attempted by eliminating the infection in dogs, reducing the population of dogs and the environmental contamination with their feces, and educating the public about the zoonotic potential of toxocariasis. The evidence reviewed indicates that these methods are only marginally effective. Because T. canis relies on congenital and lactogenic transmission to persist in nature, only a procedure that effects the sustained killing of the reservoir larvae in the tissues of the bitch, or of newly-acquired parasites, is expected to be successful. Research with mice, rabbits and dogs demonstrated that prior infections of the host induce the development of protective immunity to reinfections. This procedure, however, leaves remnant populations of larvae from the immunizing infections that are resistant to anthelmintics and to the effect of prior irradiation. Hyperimmunization with partially-purified extracts of T. canis larvae induced 37% resistance to a challenge in mice when the extract was administered alone, and 76% resistance when administered with lipopolysaccharide adjuvant. Production of complete resistance, however, will probably require the prior control of the immunosuppression induced by the parasite. T. canis infections inhibit the production of homologous protective immunity and antibody responses to heterologous antigens, probably by interfering with the activity of helper T-cells, competing with protective antigens, and suppressing antibody synthesis. The evidence indicates, however, that an anti-T. canis vaccine to eliminate the parasite in dogs is feasible.

  7. DNA-labeled micro- and nanoparticles: a new approach to study contaminant transport in the subsurface

    NASA Astrophysics Data System (ADS)

    McNew, C.; Wang, C.; Kocis, T. N.; Murphy, N. P.; Dahlke, H. E.

    2017-12-01

    Though our understanding of contaminant behavior in the subsurface has improved, our ability to measure and predict complex contaminant transport pathways at hillslope to watershed scales is still lacking. By utilizing bio-molecular nanotechnology developed for nano-medicines and drug delivery, we are able to produce DNA-labeled micro- and nanoparticles for use in a myriad of environmental systems. Control of the fabrication procedure allows us to produce particles of custom size, charge, and surface functionality to mimic the transport properties of the particulate contaminant or colloid of interest. The use of custom sequenced DNA allows for the fabrication of an enormous number of unique particle labels (approximately 1.61 x 1060 unique sequences) and the ability to discern between varied spatial and temporal applications, or the transport effect of varied particle size, charge, or surface properties. To date, this technology has been utilized to study contaminant transport from lab to field scales, including surface and open channel flow applications, transport in porous media, soil retention, and even subglacial flow pathways. Here, we present the technology for production and detection of the DNA-labeled particles along with the results from a current hillslope study at the Sierra Foothills Research and Extension Center (SFREC). This field study utilizes spatial and temporal variations in DNA-labeled particle applications to identify subsurface pollutant transport pathways through the four distinct soil horizons present at the SFREC site. Results from this and previous studies highlight the tremendous potential of the DNA-labeled particle technology for studying contaminant transport through the subsurface.

  8. 10 CFR 835.1101 - Control of material and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....1101 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Radioactive Contamination Control... section, material and equipment in contamination areas, high contamination areas, and airborne radioactivity areas shall not be released to a controlled area if: (1) Removable surface contamination levels on...

  9. Tackling antibiotic resistance: the environmental framework.

    PubMed

    Berendonk, Thomas U; Manaia, Célia M; Merlin, Christophe; Fatta-Kassinos, Despo; Cytryn, Eddie; Walsh, Fiona; Bürgmann, Helmut; Sørum, Henning; Norström, Madelaine; Pons, Marie-Noëlle; Kreuzinger, Norbert; Huovinen, Pentti; Stefani, Stefania; Schwartz, Thomas; Kisand, Veljo; Baquero, Fernando; Martinez, José Luis

    2015-05-01

    Antibiotic resistance is a threat to human and animal health worldwide, and key measures are required to reduce the risks posed by antibiotic resistance genes that occur in the environment. These measures include the identification of critical points of control, the development of reliable surveillance and risk assessment procedures, and the implementation of technological solutions that can prevent environmental contamination with antibiotic resistant bacteria and genes. In this Opinion article, we discuss the main knowledge gaps, the future research needs and the policy and management options that should be prioritized to tackle antibiotic resistance in the environment.

  10. Stardust Sample: Investigator's Guidebook

    NASA Technical Reports Server (NTRS)

    Allen, Carl

    2006-01-01

    In January 2006, the Stardust spacecraft returned the first in situ collection of samples from a comet, and the first samples of contemporary interstellar dust. Stardust is the first US sample return mission from a planetary body since Apollo, and the first ever from beyond the moon. This handbook is a basic reference source for allocation procedures and policies for Stardust samples. These samples consist of particles and particle residues in aerogel collectors, in aluminum foil, and in spacecraft components. Contamination control samples and unflown collection media are also available for allocation.

  11. Design, Qualification, and On Orbit Performance of the CALIPSO Aerosol Lidar Transmitter

    NASA Technical Reports Server (NTRS)

    Hovis, Floyd E.; Witt, Greg; Sullivan, Edward T.; Le, Khoa; Weimer, Carl; Applegate, Jeff; Luck, William S., Jr.; Verhapen, Ron; Cisewski, Michael S.

    2007-01-01

    The laser transmitter for the CALIPSO aerosol lidar mission has been operating on orbit as planned since June 2006. This document discusses the optical and laser system design and qualification process that led to this success. Space-qualifiable laser design guidelines included the use of mature laser technologies, the use of alignment sensitive resonator designs, the development and practice of stringent contamination control procedures, the operation of all optical components at appropriately derated levels, and the proper budgeting for the space-qualification of the electronics and software.

  12. Chemistry experience in the primary heat transport circuits of Kraftwerk Union pressurized water reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riess, R.

    Chosen for this description of the selected Kraftwerk Union (KWU) pressurized water reactor units were Obrigheim (KWO, 345 MW(e)), Stade (KKS, 662 (MW(e)), Borselle (KCB, 477 MW(e)), and Biblis (KWB-A, 1204 MW(e)). The experience at these plants shows that with a special startup procedure and a proper chemical control of the primary heat transport system that influences general corrosion, selective types of corrosion, corrosion product activity transport and resulting contamination, and radiation-induced decomposition, KWU units have no basic problems.

  13. Effect of feed contamination with aflatoxin B1 and administration of exogenous corticosterone on Japanese quail biochemical and immunological parameters.

    PubMed

    Nazar, F N; Magnoli, A P; Dalcero, A M; Marin, R H

    2012-01-01

    Stress is the loss of homeostasis by external forces or stressors. Manipulation, transport, contamination, and other procedures involved in production could be considered stressors. Contamination is a problem commonly faced by producers in the poultry industry. Aflatoxicosis is one of the most common infections resulting from feed contaminated with Aspergillus flavus and Aspergillus parasiticus. This study evaluated the potential effects of the combined administration of aflatoxin B(1) (AFB(1)) and corticosterone on biochemical (concentration of globulins, proteins, and albumin) and immunological (inflammatory response and heterophil:lymphocyte ratio) parameters of Japanese quail. Potential sex effects on those parameters were also considered. The provision of corticosterone in drinking water is a method used for mimicking the effects of chronic stress in avian species. At 35 d of age, 24 mixed-sex groups of 4 animals (2 males and 2 females) were housed in cages and assigned to 1 of 4 treatments: plain drinking water and laying diet, corticosterone administration in drinking water, feed contamination with AFB(1) (100 μg/kg of feed), or corticosterone plus AFB(1) administration. There were 6 cages per treatment. No significant effect of sex in any of the parameters analyzed was detected. Hypoproteinemia, hypoalbuminemia, and hypoglobulinemia were observed in animals treated with corticosterone or contaminated feed. These responses were exacerbated when the factors were combined. The immunodepressive effect of corticosterone administration was confirmed, and a higher effect was noticed when combined with the aflatoxin contamination. Aflatoxin contamination affected birds' physiology similar to a chronic stressor stimulation because it elevates the heterophil:lymphocyte ratio. This study suggests that the effects of the AFB(1) contamination are further increased when overlapped with a chronic stressful stimulation and emphasizes the importance of controlling potential stressor combinations during animal rearing to preserve not only the animal's health status but also their welfare.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farina, R.; Brandao-Mello, C.E.; Oliveira, A.R.

    In September 1987, the Goiania radiological accident involving a source of {sup 137}Cs culminated in about 140 victims who presented internal and/or external contamination and/or external exposure to radiation and/or radiation burns. Internal contamination was verified through analysis of urine and fecal samples. Internal contamination was also evaluated by measurements performed at the whole-body counter installed in Goiania in November 1987. To enhance the decorporation of 137Cs, patients were treated with the following: (1) Prussian Blue, oral administration, in 46 patients; (2) diuretics, oral administration, in 17 patients; (3) induced perspiration, increasing {sup 137}Cs elimination. These procedures were done undermore » rigorous clinical evaluation and considering the data from assay of excreta and data obtained from the whole-body counter. The doses of Prussian Blue exceeded about 6.5 times the dose previously indicated in the literature. It was the first time diuretics were used in humans to treat {sup 137}Cs internal contamination. The results of these procedures are discussed.« less

  15. Mobility and bio-availability of heavy metals in anthropogenically contaminated alluvial (deluvial) meadow soils (EUTRIC FLUVISOLS)

    NASA Astrophysics Data System (ADS)

    Dinev, Nikolai; Hristova, Mariana; Tzolova, Venera

    2015-04-01

    The total content of heavy metals is not sufficient to assess the pollution and the risk for environment as it does not provide information for the type and solubility of heavy metals' compounds in soils. The purpose was to study and determine the mobility of heavy metals in anthropogenically contaminated alluvial (delluvial) meadow soils spread around the non-ferrous plant near the town of Asenovgrad in view of risk assessment for environment pollution. Soil samples from monitoring network (1x1 km) was used. The sequential extraction procedure described by Zein and Brummer (1989) was applied. Results showed that the easily mobilizable cadmium compounds predominate in both contaminated and not contaminated soils. The stable form of copper (associated with silicate minerals, carbonates or amorphous and crystalline oxide compounds) predominates only in non polluted soils and reviles the risk of the environment contamination. Lead spreads and accumulates as highly soluble (mobile) compounds and between 72.3 and 99.6 percent of the total lead is bioavailable in soils. The procedure is very suitable for studying the mobility of technogenic lead and copper in alluvial soils with neutral medium reaction and in particular at the high levels of cadmium contamination. In soils with alkaline reaction - polluted and unpolluted the error of analysis increases for all studied elements.

  16. Laboratory, Field, and Analytical Procedures for Using ...

    EPA Pesticide Factsheets

    Regardless of the remedial technology invoked to address contaminated sediments in the environment, there is a critical need to have tools for assessing the effectiveness of the remedy. In the past, these tools have included chemical and biomonitoring of the water column and sediments, toxicity testing and bioaccumulation studies performed on site sediments, and application of partitioning, transport and fate modeling. All of these tools served as lines of evidence for making informed environmental management decisions at contaminated sediment sites. In the last ten years, a new tool for assessing remedial effectiveness has gained a great deal of attention. Passive sampling offers a tool capable of measuring the freely dissolved concentration (Cfree) of legacy contaminants in water and sediments. In addition to assessing the effectiveness of the remedy, passive sampling can be applied for a variety of other contaminated sediments site purposes involved with performing the preliminary assessment and site inspection, conducting the remedial investigation and feasibility study, preparing the remedial design, and assessing the potential for contaminant bioaccumulation. While there is a distinct need for using passive sampling at contaminated sediments sites and several previous documents and research articles have discussed various aspects of passive sampling, there has not been definitive guidance on the laboratory, field and analytical procedures for using pas

  17. Plasmonic-enhanced targeted nanohealing of metallic nanostructures

    NASA Astrophysics Data System (ADS)

    Yang, Hangbo; Lu, Jinsheng; Ghosh, Pintu; Chen, Ziyao; Wang, Wei; Ye, Hui; Yu, Qian; Qiu, Min; Li, Qiang

    2018-02-01

    Healing defects of metallic structures is an essential procedure for manufacturing and maintaining integrated devices. Current nanocomposite-assisted microhealing methodologies are inadequate for nanoscopic applications because of their concomitant contamination and limited operation accuracy. In this paper, we propose an optically controllable targeted nanohealing technique by utilizing the plasmonic-enhanced photothermal effect. The healing of nanogaps between two silver nanowires (NWs) is achieved by increasing the incident laser power in steps. Partial connection of NWs can be readily obtained using this technique, while near-perfect connection of NWs with the same crystal orientations is obtained only when the lattices on the two opposing facets are matched after recrystallization. This non-contaminating nanohealing technique not only provides deeper insight into the heat/mass transfer assisted by plasmonic photothermal conversion in the nanoscale but also suggests avenues for recovering mechanical, electronic, and photonic properties of defected metallic nanodevices.

  18. An unusual and persistent contamination of drinking water by cutting oil.

    PubMed

    Rella, R; Sturaro, A; Parvoli, G; Ferrara, D; Doretti, L

    2003-02-01

    Drinking water contamination by materials, such as cutting oil, used to set up pipelines is an uncommon but possible event. This paper describes the analytical procedures used to identify the components of that contaminant in drinking water. Volatile and semi-volatile chemical species, responsible for an unpleasant taste and odour, were recognised by solid phase microextraction and GC/MS techniques. Among the volatile compounds, the presence of xylenes, bornyl acetate and diphenyl ether was confirmed by certificate standards and quantified in the most contaminated samples.

  19. Comparison of methods to control floor contamination in an animal research facility.

    PubMed

    Allen, Kenneth P; Csida, Tarrant; Leming, Jeaninne; Murray, Kathleen; Gauld, Stephen B; Thulin, Joseph

    2012-10-01

    The authors evaluated the effectiveness of adhesive mats, contamination control flooring, and shoe covers in decreasing the presence of microbial agents on animal holding room floors and footwear. Swab samples taken from animal holding room floors after the use of each product were compared with samples taken from rooms after no products were used. Swab samples were also taken from the heels and soles of the footwear of animal care staff before and after use of each product. The use of contamination control flooring or shoe covers significantly reduced the amount of organic material (as indicated by ATP levels measured by a luminometer) present on floors. Bacterial and ATP contamination of footwear was significantly lower after the use of shoe covers than after the use of adhesive mats or contamination control flooring, and the use of shoe covers led to a greater decrease in contamination before and after use than did use of either of the other two products. Although shoe covers were superior to both adhesive mats and contamination control flooring for decreasing contamination of animal room floors and footwear, facilities must take into account the contamination control standards required, the cost of the product, and the labor and time associated with product use when deciding which contamination control practices to implement.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    JOHNSON, A.R.

    Biological control is any activity taken to prevent, limit, clean up, or remediate potential environmental, health and safety, or workplace quality impacts from plants, animals, or microorganisms. At Hanford the principal emphasis of biological control is to prevent the transport of radioactive contamination by biological vectors (plants, animals, or microorganisms), and where necessary, control and clean up resulting contamination. Other aspects of biological control at Hanford include industrial weed control (e.g.; tumbleweeds), noxious weed control (invasive, non-native plant species), and pest control (undesirable animals such as rodents and stinging insects; and microorganisms such as molds that adversely affect the qualitymore » of the workplace environment). Biological control activities may be either preventive (apriori) or in response to existing contamination spread (aposteriori). Surveillance activities, including ground, vegetation, flying insect, and other surveys, and apriori control actions, such as herbicide spraying and placing biological barriers, are important in preventing radioactive contamination spread. If surveillance discovers that biological vectors have spread radioactive contamination, aposteriori control measures, such as fixing contamination, followed by cleanup and removal of the contamination to an approved disposal location are typical response functions. In some cases remediation following the contamination cleanup and removal is necessary. Biological control activities for industrial weeds, noxious weeds and pests have similar modes of prevention and response.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    JOHNSON, A.R.

    Biological control is any activity taken to prevent, limit, clean up, or remediate potential environmental, health and safety, or workplace quality impacts from plants, animals, or microorganisms. At Hanford the principal emphasis of biological control is to prevent the transport of radioactive contamination by biological vectors (plants, animals, or microorganisms), and where necessary, control and clean up resulting contamination. Other aspects of biological control at Hanford include industrial weed control (e.g.; tumbleweeds), noxious weed control (invasive, non-native plant species), and pest control (undesirable animals such as rodents and stinging insects, and microorganisms such as molds that adversely affect the qualitymore » of the workplace environment). Biological control activities may be either preventive (a priori) or in response to existing contamination spread (a posteriori). Surveillance activities, including ground, vegetation, flying insect, and other surveys, and a priori control actions, such as herbicide spraying and placing biological barriers, are important in preventing radioactive contamination spread. If surveillance discovers that biological vectors have spread radioactive contamination, a posteriori control measures, such as fixing contamination, followed by cleanup and removal of the contamination to an approved disposal location are typical response functions. In some cases remediation following the contamination cleanup and removal is necessary. Biological control activities for industrial weeds, noxious weeds and pests have similar modes of prevention and response.« less

  2. Comparison of wiping and rinsing techniques after oral care procedures in critically ill patients during endotracheal intubation and after extubation: A prospective cross-over trial.

    PubMed

    Muramatsu, Keita; Matsuo, Koichiro; Kawai, Yusuke; Yamamoto, Tsukasa; Hara, Yoshitaka; Shimomura, Yasuyo; Yamashita, Chizuru; Nishida, Osamu

    2018-06-26

    Endotracheal intubation of critically ill patients increases the risk of aspiration pneumonia, which can be reduced by regular oral care. However, the rinsing of the residual oral contaminants after mechanical cleaning carries the risk of aspirating the residue during the intubation period. Removing the contaminants by wiping with mouth wipes could be an alternative to rinsing with water because of no additional fluid. This study tested: (i) the amount of oral bacteria during endotracheal intubation and after extubation; and (ii) the changes in the bacterial count during oral care procedures. Thirty-five mechanically ventilated patients in the intensive care unit were enrolled. The amount of bacteria on the dorsal tongue surface was counted before and following oral care and then after the elimination of contaminants either by rinsing with water and suctioning or by wiping with mouth wipes. The oral bacterial amount was compared statistically between the intubation and extubation status and among set time points during the oral care procedure. The oral bacterial count was significantly decreased after extubation. During the oral care procedure, the oral bacterial amount was significantly lower after eliminating the contaminants either by rinsing or wiping, with no remarkable difference between the elimination techniques. The findings suggest that the oral bacterial amount is elevated during endotracheal intubation, which could increase the risk of aspiration pneumonia. The significant reduction in the bacterial count by wiping indicates that it might be a suitable alternative to rinsing for mechanically ventilated patients. © 2018 Japan Academy of Nursing Science.

  3. Assessment of contamination and misclassification biases in a randomized controlled trial of a social network peer education intervention to reduce HIV risk behaviors among drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand.

    PubMed

    Simmons, Nicole; Donnell, Deborah; Ou, San-San; Celentano, David D; Aramrattana, Apinun; Davis-Vogel, Annet; Metzger, David; Latkin, Carl

    2015-10-01

    Controlled trials of HIV prevention and care interventions are susceptible to contamination. In a randomized controlled trial of a social network peer education intervention among people who inject drugs and their risk partners in Philadelphia, PA and Chiang Mai, Thailand, we tested a contamination measure based on recall of intervention terms. We assessed the recall of test, negative and positive control terms among intervention and control arm participants and compared the relative odds of recall of test versus negative control terms between study arms. The contamination measures showed good discriminant ability among participants in Chiang Mai. In Philadelphia there was no evidence of contamination and little evidence of diffusion. In Chiang Mai there was strong evidence of diffusion and contamination. Network structure and peer education in Chiang Mai likely led to contamination. Recall of intervention materials can be a useful method to detect contamination in experimental interventions.

  4. Shuttle on-orbit contamination and environmental effects

    NASA Technical Reports Server (NTRS)

    Leger, L. J.; Jacobs, S.; Ehlers, H. K. F.; Miller, E.

    1985-01-01

    Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

  5. Contamination of dental unit water and air outlets following use of clean head system and conventional handpieces.

    PubMed

    Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian

    2007-01-01

    Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

  6. Arsenic bio-accessibility and bioaccumulation in aged pesticide contaminated soils: A multiline investigation to understand environmental risk.

    PubMed

    Rahman, M S; Reichelt-Brushet, A J; Clark, M W; Farzana, T; Yee, L H

    2017-03-01

    Bio-accessibility and bioavailability of arsenic (As) in historically As-contaminated soils (cattle tick pesticide), and pristine soils were assessed using 3 different approaches. These approaches included human bio-accessibility using an extraction test replicating gastric conditions (in vitro physiologically-based extraction test); an operationally defined bioaccessibility extraction test - 1.0M HCl extraction; and a live organism bioaccumulation test using earthworms. A sequential extraction procedure revealed the soil As-pool that controls bio-accessibility and bioaccumulation of As. Findings show that As is strongly bound to historically contaminated soil with a lower degree of As bio-accessibility (<15%) and bioaccumulation (<9%) compared with freshly contaminated soil. Key to these lower degrees of bio-accessibility and bioaccumulation is the greater fraction of As associated with crystalline Fe/Al oxy-hydroxide and residual phases. The high bio-accessibility and bioaccumulation of freshly sorbed As in pristine soils were from the exchangeable and specifically sorbed As fractions. Arsenic bioaccumulation in earthworms correlates strongly with both the human bio-accessible, and the operationally defined bioavailable fractions. Hence, results suggest that indirect As bioavailability measures, such as accumulation by earthworm, can be used as complementary lines of evidence to reinforce site-wide trends in the bio-accessibility using in vitro physiologically-based extractions and/or operationally defined extraction test. Such detailed knowledge is useful for successful reclamation and management of the As contaminated soils. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. In Vitro Microbiology Studies on a New Peritoneal Dialysis Connector

    PubMed Central

    Di Bonaventura, Giovanni; Cerasoli, Paolo; Pompilio, Arianna; Arrizza, Fabio; Di Liberato, Lorenzo; Stingone, Antonio; Sirolli, Vittorio; Arduini, Arduino; Bonomini, Mario

    2012-01-01

    ♦ Objective: We evaluated the ability of a recently developed peritoneal dialysis (PD) connector to prevent the risk of bacterial transfer to the fluid path after simulated touch and airborne contamination. ♦ Methods: Staphylococcus epidermidis ATCC1228 and Pseudomonas aeruginosa ATCC27853 strains were used. For touch contamination, 2 μL of a standardized inoculum [1×108 colony-forming units (CFU) per milliliter] were deposited on top of the pin closing the fluid path of the patient connector. For airborne contamination, the patient connector was exposed for 15 seconds to a nebulized standardized inoculum. To simulate the patient peritoneum and effluent, the patient connector was pre-attached to a 2-L bag of sterile PD solution. After contamination, the patient connector was attached to the transfer set, the pin was captured, flow control was turned to simulate “patient drain” into the empty bag, and then “patient fill” using the bag pre-attached to the connector. Finally, a new pin was recaptured. The PD solution collected in the bag pre-attached to the connector was run through a 0.20-μm filter for colony counts. ♦ Results: No infected connector transferred bacteria to the fluid path, regardless of the challenge procedure or the strain used. ♦ Conclusions: Our results show that the new PD connector may fully obviate the risk of bacterial infection, even in the presence of heavy contamination. Further studies are in progress to test our PD connector in a clinical setting. PMID:22302771

  8. Prevention and control practices for human noroviruses in long-term care facilities in South Carolina.

    PubMed

    Leone, Cortney M; Jayasekara, Lalani; Sharp, Julia; Fraser, Angela

    2015-12-01

    Long-term care facilities (LTCFs) are the most common setting for human norovirus (HuNoV) outbreak. Our study aimed to determine gaps in prevention and control practices for HuNoV in LTCFs in South Carolina (SC). Two researchers visited a convenience sample of 26 LTCFs in SC during July-November 2013. Directors were interviewed to determine facility prevention and control practices. Relative frequencies and means were calculated using SAS 9.3 (SAS Institute, Cary, NC). Most directors had little knowledge of proper sanitizing and disinfecting products and reported missing written procedures for cleaning staff-visitor bathrooms. Only 18 had recommendations for when residents should wash hands. Many used the wrong products for pathogen removal after vomit-fecal events, had no written procedures for cleaning contaminated soft surfaces, did not remove other individuals during clean-up of vomit-fecal episodes, and did not clean a large area surrounding vomit-fecal episodes. Eighteen did not assign specific staff to care for sick; 16 did not designate specific toilets for sick; and 15 did not restrict visitors during an outbreak. Directors' responses indicated gaps in prevention and control practices for HuNoV in LTCFs in SC. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Exogenous contamination of uranium in human scalp hair.

    PubMed

    Muikku, Maarit; Heikkinen, Tarja

    2012-06-01

    The use of human scalp hair as a bioindicator of occupational or environmental exposure has been the subject of some debate over the years. One problem is how to distinguish internal contamination from external contamination. In this study, possibility that elevated levels of natural uranium in human hair are partly due to the exogenously bound uranium from uranium-rich household water was tested. Hair samples from six adult volunteers were cut and then exposed externally to uranium by using washing water with highly elevated levels of natural uranium. After that, and before making the analysis using inductively coupled plasma mass spectrometry (ICP-MS), the samples were washed using two commonly used washing procedures in order to remove external contamination. No quantitative information was gained in the tests, but it was shown that the use of uranium-rich water when washing hair affects the uranium concentration in hair. Although the samples were cleaned according to widely used washing procedures before the analysis, the uranium concentrations in hair were about three orders of magnitude higher after the tests. The possibility of external contamination should be kept in mind, especially when considering hair as an excretion pathway for estimating internal dose.

  10. Experience of microbiological screening of human hepatocytes for clinical transplantation.

    PubMed

    Lehec, Sharon C; Hughes, Robin D; Mitry, Ragai R; Graver, Michelle A; Verma, Anita; Wade, Jim J; Dhawan, Anil

    2009-01-01

    Hepatocyte transplantation is being used in patients with liver-based metabolic disorders and acute liver failure. Hepatocytes are isolated from unused donor liver tissue under GMP conditions. Cells must be free of microbiological contamination to be safe for human use. The experience of microbiological screening during 72 hepatocyte isolation procedures at one center is reported. Samples were taken at different stages of the process and tested using a blood culture bottle system and Gram stain. Bacterial contamination was detected in 37.5% of the UW organ preservative solutions used to transport the liver tissue to the Cell Isolation Unit. After tissue processing the contamination was reduced to 7% overall in the final hepatocyte product, irrespective of the presence of initial contamination of the transport solution. The most common organisms recovered were coagulase-negative staphylococci, a skin commensal. A total of 41 preparations of fresh or cryopreserved hepatocytes were used for cell transplantation in children with liver-based metabolic disorders without any evidence of sepsis due to infusion of hepatocytes. In conclusion, the incidence of bacterial contamination of the final product was low, confirming the suitability of the organs used, hepatocyte isolation procedure, and the environmental conditions of the clean room.

  11. Evaluating specificity of sequential extraction for chemical forms of lead in artificially-contaminated and field-contaminated soils.

    PubMed

    Tai, Yiping; McBride, Murray B; Li, Zhian

    2013-03-30

    In the present study, we evaluated a commonly employed modified Bureau Communautaire de Référence (BCR test) 3-step sequential extraction procedure for its ability to distinguish forms of solid-phase Pb in soils with different sources and histories of contamination. When the modified BCR test was applied to mineral soils spiked with three forms of Pb (pyromorphite, hydrocerussite and nitrate salt), the added Pb was highly susceptible to dissolution in the operationally-defined "reducible" or "oxide" fraction regardless of form. When three different materials (mineral soil, organic soil and goethite) were spiked with soluble Pb nitrate, the BCR sequential extraction profiles revealed that soil organic matter was capable of retaining Pb in more stable and acid-resistant forms than silicate clay minerals or goethite. However, the BCR sequential extraction for field-collected soils with known and different sources of Pb contamination was not sufficiently discriminatory in the dissolution of soil Pb phases to allow soil Pb forms to be "fingerprinted" by this method. It is concluded that standard sequential extraction procedures are probably not very useful in predicting lability and bioavailability of Pb in contaminated soils. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Relaxation Time Distribution (RTD) of Spectral Induced Polarization (SIP) data from environmental studies

    NASA Astrophysics Data System (ADS)

    Ntarlagiannis, D.; Ustra, A.; Slater, L. D.; Zhang, C.; Mendonça, C. A.

    2015-12-01

    In this work we present an alternative formulation of the Debye Decomposition (DD) of complex conductivity spectra, with a new set of parameters that are directly related to the continuous Debye relaxation model. The procedure determines the relaxation time distribution (RTD) and two frequency-independent parameters that modulate the induced polarization spectra. The distribution of relaxation times quantifies the contribution of each distinct relaxation process, which can in turn be associated with specific polarization processes and characterized in terms of electrochemical and interfacial parameters as derived from mechanistic models. Synthetic tests show that the procedure can successfully fit spectral induced polarization (SIP) data and accurately recover the RTD. The procedure was applied to different data sets, focusing on environmental applications. We focus on data of sand-clay mixtures artificially contaminated with toluene, and crude oil-contaminated sands experiencing biodegradation. The results identify characteristic relaxation times that can be associated with distinct polarization processes resulting from either the contaminant itself or transformations associated with biodegradation. The inversion results provide information regarding the relative strength and dominant relaxation time of these polarization processes.

  13. Two-step purification of His-tagged Nef protein in native condition using heparin and immobilized metal ion affinity chromatographies.

    PubMed

    Finzi, Andrés; Cloutier, Jonathan; Cohen, Eric A

    2003-07-01

    The Nef protein encoded by human immunodeficiency virus type 1 (HIV-1) has been shown to be an important factor of progression of viral growth and pathogenesis in both in vitro and in vivo. The lack of a simple procedure to purify Nef in its native conformation has limited molecular studies on Nef function. A two-step procedure that includes heparin and immobilized metal ion affinity chromatographies (IMACs) was developed to purify His-tagged Nef (His(6)-Nef) expressed in bacteria in native condition. During the elaboration of this purification procedure, we identified two closely SDS-PAGE-migrating contaminating bacterial proteins, SlyD and GCHI, that co-eluted with His(6)-Nef in IMAC in denaturing condition and developed purification steps to eliminate these contaminants in native condition. Overall, this study describes a protocol that allows rapid purification of His(6)-Nef protein expressed in bacteria in native condition and that removes metal affinity resin-binding bacterial proteins that can contaminate recombinant His-tagged protein preparation.

  14. A surgical support system for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Campbell, M. R.; Billica, R. D.; Johnston, S. L.

    1992-01-01

    Surgical techniques in microgravity are being developed for the Health Maintenance Facility (HMF) on Space Station Freedom (SSF). This will be a presentation of the proposed surgical capabilities and ongoing hardware and procedural investigations. Methods: Procedures and prototype hardware, which include a medical restraint system, a surgical overhead isolation canopy, a suction device, and a regional laminar flow device were evaluated. This was accomplished by realistic sterile surgical simulations involving both mannequins and animals during KC-135 parabolic flight and in a high fidelity ground based HMF mockup. Results: Animal surgery in the environment of microgravity allowed the observation of unique arterial and venous bleeding characteristics for the first time. The ability to control bleeding and to prevent cabin atmosphere contamination was also demonstrated. Conclusions: The procedures and prototype hardware tested provided valuable information and should be investigated and developed further. The use of standard surgical techniques are possible in microgravity if the principles of personnel and supply restraint and operative field containment are adhered to.

  15. Producing Low-Oxygen Samarium/Cobalt Magnet Alloy

    NASA Technical Reports Server (NTRS)

    Das, Dilip K.; Kumar, Kaplesh; Frost, Robert T.; Chang, C. W.

    1987-01-01

    Experiments aimed at producing SmCo5 alloy with low oxygen contamination described in report. Two methods of alloying by melting without contact with crucible walls tested. Lowest oxygen contamination, 70 parts per million achieved by dc arc melting on water-cooled, tantalum-clad copper hearth in purified quiescent argon atmosphere. Report includes photographs of equipment, photomicrographs of alloy samples, detailed descriptions of procedures tried, and tables of oxygen contamination and intrinsic coercivities of samples produced.

  16. The characterization of organic contaminants during the development of the Space Station water reclamation and management system

    NASA Technical Reports Server (NTRS)

    Cole, H.; Habercom, M.; Crenshaw, M.; Johnson, S.; Manuel, S.; Martindale, W.; Whitman, G.; Traweek, M.

    1991-01-01

    Examples of the application of various methods for characterizing samples for alcohols, fatty acids, detergents, and volatile/semivolatile basic, neutral, and phenolic acid contaminants are presented. Data, applications, and interpretations are given for a variety of methods including sample preparation/cleanup procedures, ion chromatography, and gas chromatography with various detectors. Summaries of the major organic contaminants that contribute to the total organic carbon content are presented.

  17. CTEPP STANDARD OPERATING PROCEDURE FOR PRE-CLEANING FILTERS AND XAD-2 (SOP-5.10)

    EPA Science Inventory

    This SOP summarizes the method for pre-cleaning XAD-2 resin and quartz fiber filters. The procedure provides a cleaning method to help reduce potential background contamination in the resin and filters.

  18. Bedding disposal cabinet for containment of aerosols generated by animal cage cleaning procedures.

    PubMed Central

    Baldwin, C L; Sabel, F L; Henke, C B

    1976-01-01

    Laboratory tests with aerosolized spores and animal room tests with uranine dye indicate the effectiveness of a prototype bedding disposal cabinet in reducing airborne contamination generated by cage cleaning procedures. Images PMID:826219

  19. 10 CFR 36.53 - Operating and emergency procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... pool, or another alarmed area; (9) Natural phenomena, including an earthquake, a tornado, flooding, or...) Monitoring pool water for contamination while the water is in the pool and before release of pool water to... or pool monitor; (4) Detection of leaking sources, pool contamination, or alarm caused by...

  20. Wide Area Recovery and Resiliency Program (WARRP) Interim Clearance Strategy for Environments Contaminated with Cesium-137

    DTIC Science & Technology

    2012-07-01

    Goiania) and those containing 137Cs and other radionuclides ( Chernobyl ). Another group contains documents relevant to site survey 3 procedures...residents of the contaminated areas. Recovery experience from the Chernobyl incident have demonstrated that direct involvement of inhabitants and local

  1. Methods for the Determination of Chemical Contaminants in Drinking Water. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual, intended for chemists and technicians with little or no experience in chemical procedures required to monitor drinking water, covers analytical methods for inorganic and organic chemical contaminants listed in the interim primary drinking water regulations. Topics include methods for heavy metals, nitrate, and organic…

  2. Methods for the Determination of Bacteriological Contaminants in Drinking Water. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    Material on the membrane filter methods and the most probable number method for determining bacteriological contaminants listed in the interim primary drinking water regulations is presented. This course is for bacteriologists and technicians with little or no experience in bacteriological procedures required to monitor drinking water, though…

  3. 76 FR 77371 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-13

    ... advise the flightcrew of procedures to follow to ensure that a fuel filter impending bypass condition due... message to the flightcrew of a left engine fuel filter contamination and imminent bypass condition, which... prevents the display of an advisory message to the flightcrew of a left engine fuel filter contamination...

  4. Survey of Intraoperative Bacterial Contamination in Dogs Undergoing Elective Orthopedic Surgery.

    PubMed

    Andrade, Natalia; Schmiedt, Chad W; Cornell, Karen; Radlinsky, MaryAnn G; Heidingsfelder, Lauren; Clarke, Kevin; Hurley, David J; Hinson, Whitney D

    2016-02-01

    To investigate the frequency, source, and risk factors of intraoperative (IO) surgeon and patient bacterial contamination during clean orthopedic surgeries, and to investigate the relationship between IO contamination and surgical site infection (SSI) in dogs. Prospective clinical study. Client-owned dogs undergoing stifle surgery (n = 100). IO cultures were taken in each case from surgical foot wrap, peri-incisional skin, surgical gloves, and the surgical team's hands. The environment (operating room [OR] lights, computers, scrub sink faucet, anesthesia gurney, and radiology table) was sampled every 5 months. Bacteria were identified and the contamination of each case was categorized. All gloves from the surgical team were collected and tested for perforations using a water infusion test. Cases were followed for at least 8 weeks to determine the presence or absence of SSI. Perioperative variables were evaluated for association with IO contamination and SSI. Bacterial isolates were yielded from 81% of procedures from 1 or more sources; 58% had positive hand cultures, 46% had positive glove cultures, 23% had positive patient skin cultures, and 12% had positive foot wrap cultures. Staphylococcus spp. was the most commonly recovered bacteria. There was no apparent association between IO contamination and SSI. The highest level of environmental contamination was associated with the scrub sink faucet, followed by the radiology table, anesthesia gurney, and OR computers. The IO glove perforation rate was 18%. Clean orthopedic procedures commonly had clinically insignificant bacterial contamination. In our study, bacteria responsible for SSI did not appear to colonize the patient in the OR. © Copyright 2016 by The American College of Veterinary Surgeons.

  5. Experimental assessment of disinfection procedures for eradication of Aspergillus fumigatus in food.

    PubMed

    Gangneux, Jean-Pierre; Noussair, Latifa; Bouakline, Adel; Roux, Nicole; Lacroix, Claire; Derouin, Francis

    2004-10-01

    Aspergillus fumigatus spores in food may represent an infectious risk for neutropenic patients. We examined the efficiency of disinfection procedures applicable to foods for eradication of A fumigatus. Boiling and microwave treatment fully decontaminated an experimental spore suspension and naturally contaminated liquid foods (reconstituted dried food, herbal tea). Full decontamination of experimentally contaminated surfaces was only obtained with 70% ethanol or heating at 220 degrees C for 15 minutes. Pepper was decontaminated when heated for 15 minutes at 220 degrees C but not by microwaving. Fruit skin was partially decontaminated by 70% ethanol. We conclude that A fumigatus spores can be eradicated from food by heating to a temperature of at least 100 degrees C. When foods cannot be exposed to high temperature or microwaving, ethanol only partially reduces the level of surface contamination.

  6. European isolation and confinement study. Additional experiments.

    PubMed

    Novara, M

    1993-01-01

    Microbiological Experiments. The ISEMSI microbiological contamination experiments confirmed known hypotheses, such as: the trend toward uniformity of skin microbial flora across a group of individuals enclosed together; the rather fast "colonization" of the environment by microorganisms shed by human inhabitants; and the heavy growth of microorganisms in poorly accessible and wet areas (toilets, air conditioning). In addition, possible disturbances of skin defense mechanisms against colonization by potentially pathogenic microbes were noted, as well as a difficulty in monitoring the microbial contents of the atmosphere (significant random variations occur between samples taken at different times and locations). Sensors for Atmospheric Contaminants. Several different prototypes of "array sensors" for the monitoring of trace gas contaminants in the atmosphere were evaluated during ISEMSI. Their performance was promising when compared with results achieved with a more conventional (and more complex) gas chromatograph/mass spectrometer device, also used during ISEMSI. An overall picture of the most important chemical contaminants to be found in enclosed, manned habitats (including contaminants produced by man himself) was obtained via the use of Tenax gas-adsorption traps. This permitted monitoring the fluctuation of contaminants on a daily basis, as well as during the complete 4-week period. Results will provide a valuable input for designing systems to monitor and control atmospheric contamination in future spacecraft. Particular attention was devoted to the monitoring of carbon monoxide in the chamber. Results showing the correlation between its concentration in the atmosphere and the percentage of carboxyhemoglobin in the EMSInauts' blood will allow the evaluation of the correctness of the presently specified maximum allowable concentration for spacecraft. Telemedicine Experiment. The telemedicine experiment confirmed the feasibility and importance of applying to a space station scenario many aspects of remote health care already widely used in the maritime environment. ISEMSI successfully evaluated telemedical consultation procedures and training protocols for the crew. EMSInauts, trained as paramedical assistants, had to interview a "patient" (another EMSInaut, trained to feign illness symptoms), prepare an anamnesis, carry out a medical examination, assess the severity of the case, and administer effective medical care under remote medical advice. An expert system was used to provide step-by-step guidance to the paramedical assistant. ISEMSI demonstrated the great importance of practicing and rehearsing emergency procedures; it confirmed that simulation of medical emergencies during an actual long-duration space mission will be required to provide "refresher training" to astronauts trained as paramedical assistants.(ABSTRACT TRUNCATED AT 400 WORDS)

  7. JPL Contamination Control Engineering

    NASA Technical Reports Server (NTRS)

    Blakkolb, Brian

    2013-01-01

    JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

  8. Standard operating procedures for collection of soil and sediment samples for the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study

    USGS Publications Warehouse

    Fisher, Shawn C.; Reilly, Timothy J.; Jones, Daniel K.; Benzel, William M.; Griffin, Dale W.; Loftin, Keith A.; Iwanowicz, Luke R.; Cohl, Jonathan A.

    2015-12-17

    An understanding of the effects on human and ecological health brought by major coastal storms or flooding events is typically limited because of a lack of regionally consistent baseline and trends data in locations proximal to potential contaminant sources and mitigation activities, sensitive ecosystems, and recreational facilities where exposures are probable. In an attempt to close this gap, the U.S. Geological Survey (USGS) has implemented the Sediment-bound Contaminant Resiliency and Response (SCoRR) strategy pilot study to collect regional sediment-quality data prior to and in response to future coastal storms. The standard operating procedure (SOP) detailed in this document serves as the sample-collection protocol for the SCoRR strategy by providing step-by-step instructions for site preparation, sample collection and processing, and shipping of soil and surficial sediment (for example, bed sediment, marsh sediment, or beach material). The objectives of the SCoRR strategy pilot study are (1) to create a baseline of soil-, sand-, marsh sediment-, and bed-sediment-quality data from sites located in the coastal counties from Maine to Virginia based on their potential risk of being contaminated in the event of a major coastal storm or flooding (defined as Resiliency mode); and (2) respond to major coastal storms and flooding by reoccupying select baseline sites and sampling within days of the event (defined as Response mode). For both modes, samples are collected in a consistent manner to minimize bias and maximize quality control by ensuring that all sampling personnel across the region collect, document, and process soil and sediment samples following the procedures outlined in this SOP. Samples are analyzed using four USGS-developed screening methods—inorganic geochemistry, organic geochemistry, pathogens, and biological assays—which are also outlined in this SOP. Because the SCoRR strategy employs a multi-metric approach for sample analyses, this protocol expands upon and reconciles differences in the sample collection protocols outlined in the USGS “National Field Manual for the Collection of Water-Quality Data,” which should be used in conjunction with this SOP. A new data entry and sample tracking system also is presented to ensure all relevant data and metadata are gathered at the sample locations and in the laboratories.

  9. Quest for a Realistic In Vivo Test Method for Antimicrobial Hand-Rub Agents: Introduction of a Low-Volume Hand Contamination Procedure▿

    PubMed Central

    Macinga, David R.; Beausoleil, Christopher M.; Campbell, Esther; Mulberry, Gayle; Brady, Ann; Edmonds, Sarah L.; Arbogast, James W.

    2011-01-01

    A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378). PMID:22003004

  10. Contamination control research activities for space optics in JAXA RANDD

    NASA Astrophysics Data System (ADS)

    Kimoto, Y.

    2017-11-01

    Contamination control research activities for space optics projects in JAXA R&D are described. More accurate contamination control techniques are requested because of intensified recent science mission requirements. One approach to control the contamination effects is analysis by software. JAXA has been developing a contamination analytical tool "J-SPICE" (Japanese Spacecraft Induced Contamination analysis software) as well as experiment facilities to improve the J-SPICE. A reflection model in J-SPICE has been experimentally verified and outgassing model data has been acquired by a facility. JAXA has developed a facility which could determine the influence of the contamination at a specific wavelength by combining a vacuum chamber with an I-R spectrometer and performed an experiment to inspect the effect of baking. Space material exposure experiment results reveal the actual thickness of the contamination layer in ISS orbit.

  11. Improved system for floor cleaning in health care facilities.

    PubMed Central

    Schmidt, E A; Coleman, D L; Mallison, G F

    1984-01-01

    A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mopping . The effectiveness of the procedures was evaluated by means of surface sampling for bacterial contamination and air sampling for airborne bacteria and dust. The level of bacterial contamination on the floors was reduced by 93.6% by using the new system, compared with 79.8% by using the conventional process of dust mopping and wet mopping with a disinfectant solution. The levels of airborne bacteria during and after the individual procedures did not vary significantly from the initial level (123.6 CFU/per m3 of air). A survey of representative colonies from air samples revealed staphylococci, gram-positive bacilli, gram-positive diplococci, yeast cells, and infrequent gram-negative rods. The distribution at the conclusion of the sanitizing process was similar to that at the outset. Similarly, the levels of airborne dust measured during and after the individual procedures did not vary significantly from the initial level. When compared with the traditional method of cleaning by wet mopping , the new method was significantly more effective in removal of microbial contamination and required less labor. PMID:6742835

  12. Influence of cleaning methods on resin bonding to saliva-contaminated zirconia.

    PubMed

    Yoshida, Keiichi

    2018-02-08

    The aim of this study was to investigate the influence of different cleaning methods on the shear bond strengths of 2 resin cements to saliva-contaminated zirconia. After saliva contamination, alumina-blasted zirconia specimens were cleaned with 1 of 5 methods of water-rinsing (SA), K-etchant GEL phosphoric acid (PA), Ivoclean (IC), AD Gel (ADG), or additional alumina-blasting (AB). Alumina-blasted zirconia without saliva contamination was used as control group (Cont). Composite cylinders were bonded to the zirconia with 1 of 2 dual-cured resin cements. The bond strengths were measured by shear testing after 24 hours (TC0) and after thermal cycling at 4°C-60°C (TC10 000) and specimen surfaces were evaluated using X-ray photoelectron spectroscopy (XPS). Data were statistically analyzed using 3-way analysis of variance and Tukey test (α = 0.05). There were no significant differences in the bond strengths of 2 resin cements between the Cont ADG, and AB groups before and after TCs (P > .05). SA, PA, and IC groups did not exhibit durable resin bonding to zirconia. XPS showed that carbon and nitrogen increased in the SA group in comparison to the Cont group. The concentration of carbon in other 4 groups returned to the concentration range of the Cont group; however, nitrogen was not detected in the only AB group. Saliva contamination significantly reduced the bond strength of 2 resin cements to zirconia. Additional AB or cleaning with ADG resulted in effective cleaning of saliva contamination and preserved resin cement bond strength to zirconia. Saliva contamination occurs during clinical procedures for adjustment of zirconia ceramic restorations in the oral environment. AD Gel application is effective for removing saliva contaminants on the alumina-blasted zirconia surface beforehand by the dental laboratory instead of additional AB since AD Gel application and AB had a similar effect on the removal of organic components of saliva. © 2018 Wiley Periodicals, Inc.

  13. Cadastral valuation of land contaminated with radionuclides

    NASA Astrophysics Data System (ADS)

    Ratnikov, A. N.; Sapozhnikov, P. M.; Sanzharova, N. I.; Sviridenko, D. G.; Zhigareva, T. L.; Popova, G. I.; Panov, A. V.; Kozlova, I. Yu.

    2016-01-01

    The methodology and procedure for cadastral valuation of land in the areas contaminated with radionuclides are presented. The efficiency of rehabilitation measures applied to decrease crop contamination to the levels satisfying sanitary-hygienic norms is discussed. The differentiation of cadastral value of radioactively contaminated agricultural lands for the particular farms and land plots is suggested. An example of cadastral valuation of agricultural land contaminated during the Chernobyl Nuclear Power Plant accident is given. It is shown that the use of sandy and loamy sandy soddy-podzolic soils with the 137Cs contamination of 37-185 and >185 kBq/m2 for crop growing is unfeasible. The growing of grain crops and potatoes on clay loamy soddy-podzolic soils with the 137Cs contamination of 555-740 kBq/m2 is unprofitable. The maximum cadastral value of radioactively contaminated lands is typical of leached chernozems.

  14. Assessment of contamination and misclassification biases in a randomized controlled trial of a social network peer education intervention to reduce HIV risk behaviors among drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand

    PubMed Central

    Simmons, Nicole; Donnell, Deborah; Ou, San-san; Celentano, David D.; Aramrattana, Apinun; Davis-Vogel, Annet; Metzger, David; Latkin, Carl

    2015-01-01

    Context Controlled trials of educational interventions are susceptible to contamination. Objectives To test a contamination measure based on recall of terms. Main study A randomized controlled trial of a social network peer education intervention among 1,123 injection drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand. Methods We assessed the recall of test, negative and positive control terms by intervention and control arm participants and compared the relative odds (OR) of recall of test vs. negative control terms between study arms. Results The contamination measure showed good discriminant ability only among participants from Chiang Mai. In Philadelphia there was no evidence of contamination and little evidence of diffusion. In Chiang Mai there was evidence of diffusion and contamination of 4 of 5 terms tested. Conclusions Network structure and peer education in Chiang Mai likely led to contamination. Recall of intervention materials can be a useful method to detect contamination in trials of educational interventions. PMID:25935214

  15. Functional Agents to Biologically Control Deoxynivalenol Contamination in Cereal Grains

    PubMed Central

    Tian, Ye; Tan, Yanglan; Liu, Na; Liao, Yucai; Sun, Changpo; Wang, Shuangxia; Wu, Aibo

    2016-01-01

    Mycotoxins, as microbial secondary metabolites, frequently contaminate cereal grains and pose a serious threat to human and animal health around the globe. Deoxynivalenol (DON), a commonly detected Fusarium mycotoxin, has drawn utmost attention due to high exposure levels and contamination frequency in the food chain. Biological control is emerging as a promising technology for the management of DON contamination. Functional biological control agents (BCAs), which include antagonistic microbes, natural fungicides derived from plants and detoxification enzymes, can be used to control DON contamination at different stages of grain production. In this review, studies regarding different biological agents for DON control in recent years are summarized for the first time. Furthermore, this article highlights the significance of BCAs for controlling DON contamination, as well as the need for more practical and efficient BCAs concerning food safety. PMID:27064760

  16. International Space Station External Contamination Status

    NASA Technical Reports Server (NTRS)

    Mikatarian, Ron; Soares, Carlos

    2000-01-01

    PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.

  17. Parameterizing sorption isotherms using a hybrid global-local fitting procedure.

    PubMed

    Matott, L Shawn; Singh, Anshuman; Rabideau, Alan J

    2017-05-01

    Predictive modeling of the transport and remediation of groundwater contaminants requires an accurate description of the sorption process, which is usually provided by fitting an isotherm model to site-specific laboratory data. Commonly used calibration procedures, listed in order of increasing sophistication, include: trial-and-error, linearization, non-linear regression, global search, and hybrid global-local search. Given the considerable variability in fitting procedures applied in published isotherm studies, we investigated the importance of algorithm selection through a series of numerical experiments involving 13 previously published sorption datasets. These datasets, considered representative of state-of-the-art for isotherm experiments, had been previously analyzed using trial-and-error, linearization, or non-linear regression methods. The isotherm expressions were re-fit using a 3-stage hybrid global-local search procedure (i.e. global search using particle swarm optimization followed by Powell's derivative free local search method and Gauss-Marquardt-Levenberg non-linear regression). The re-fitted expressions were then compared to previously published fits in terms of the optimized weighted sum of squared residuals (WSSR) fitness function, the final estimated parameters, and the influence on contaminant transport predictions - where easily computed concentration-dependent contaminant retardation factors served as a surrogate measure of likely transport behavior. Results suggest that many of the previously published calibrated isotherm parameter sets were local minima. In some cases, the updated hybrid global-local search yielded order-of-magnitude reductions in the fitness function. In particular, of the candidate isotherms, the Polanyi-type models were most likely to benefit from the use of the hybrid fitting procedure. In some cases, improvements in fitness function were associated with slight (<10%) changes in parameter values, but in other cases significant (>50%) changes in parameter values were noted. Despite these differences, the influence of isotherm misspecification on contaminant transport predictions was quite variable and difficult to predict from inspection of the isotherms. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Ultra-trace analysis of hormones, pharmaceutical substances, alkylphenols and phthalates in two French natural mineral waters.

    PubMed

    Dévier, Marie-Hélène; Le Menach, Karyn; Viglino, Liza; Di Gioia, Lodovico; Lachassagne, Patrick; Budzinski, Hélène

    2013-01-15

    The aim of this work was to investigate the potential presence of a broad range of organic compounds, such as hormones, alkylphenols, bisphenol A and phthalates, as well as pharmaceutical substances in two brands of bottled natural mineral waters (Evian and Volvic, Danone). The phthalates were determined by solid-phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC-MS) and the other compounds by liquid chromatography-tandem mass spectrometry (LC-MS/MS) or gas chromatography-mass spectrometry (GC-MS) after solid-phase extraction. The potential migration of alkylphenols, bisphenol A and phthalates from polyethylene terephthalate (PET) bottles was also investigated under standardized test conditions. Evian and Volvic natural mineral waters contain none of the around 120 targeted organic compounds. Traces of 3 pharmaceuticals (ketoprofen, salicylic acid, and caffeine), 3 alkylphenols (4-nonylphenol, 4-t-octylphenol, and 4-nonylphenol diethoxylate), and some phthalates including di(2-ethylhexyl)phthalate (DEHP) were detected in the samples, but they were also present in the procedural blanks at similar levels. The additional test procedures demonstrated that the few detected compounds originated from the background laboratory contamination. Analytical procedures have been designed both in the bottling factory and in the laboratory in order to investigate the sources of DEHP and to minimize to the maximum this unavoidable laboratory contamination. It was evidenced that no migration of the targeted compounds from bottles occurred under the test conditions. The results obtained in this study underline the complexity of reaching a reliable measure to qualify the contamination of a sample at ultra-trace level, in the field of very pure matrices. The analytical procedures involving glassware, equipment, hoods, and rooms specifically dedicated to trace analysis allowed us to reach reliable procedural limits of quantification at the ng/L level, by lowering the background laboratory contamination. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Identification and analysis of damaged or porous hair.

    PubMed

    Hill, Virginia; Loni, Elvan; Cairns, Thomas; Sommer, Jonathan; Schaffer, Michael

    2014-06-01

    Cosmetic hair treatments have been referred to as 'the pitfall' of hair analysis. However, most cosmetic treatments, when applied to the hair as instructed by the product vendors, do not interfere with analysis, provided such treatments can be identified by the laboratory and the samples analyzed and reported appropriately for the condition of the hair. This paper provides methods for identifying damaged or porous hair samples using digestion rates of hair in dithiothreitol with and without proteinase K, as well as a protein measurement method applied to dithiothreitol-digested samples. Extremely damaged samples may be unsuitable for analysis. Aggressive and extended aqueous washing of hair samples is a proven method for removing or identifying externally derived drug contamination of hair. In addition to this wash procedure, we have developed an alternative wash procedure using 90% ethanol for washing damaged or porous hair. The procedure, like the aqueous wash procedure, requires analysis of the last of five washes to evaluate the effectiveness of the washing procedure. This evaluation, termed the Wash Criterion, is derived from studies of the kinetics of washing of hair samples that have been experimentally contaminated and of hair from drug users. To study decontamination methods, in vitro contaminated drug-negative hair samples were washed by both the aqueous buffer method and a 90% ethanol method. Analysis of cocaine and methamphetamine was by liquid chromatography-tandem mass spectrometry (LC/MS/MS). Porous hair samples from drug users, when washed in 90% ethanol, pass the wash criterion although they may fail the aqueous wash criterion. Those samples that fail both the ethanolic and aqueous wash criterion are not reported as positive for ingestion. Similar ratios of the metabolite amphetamine relative to methamphetamine in the last wash and the hair is an additional criterion for assessing contamination vs. ingestion of methamphetamine. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Toxicity and bioaccumulation of sediment-associated contaminants using freshwater invertebrates: A review of methods and applications

    USGS Publications Warehouse

    Ingersoll, C.G.; Ankley, G.T.; Benoit, D.A.; Brunson, E.L.; Burton, G.A.; Dwyer, F.J.; Hoke, R.A.; Landrum, P.F.; Norberg-King, T. J.; Winger, P.V.

    1995-01-01

    This paper reviews recent developments in methods for evaluating the toxicity and bioaccumulation of contaminants associated with freshwater sediments and summarizes example case studies demonstrating the application of these methods. Over the past decade, research has emphasized development of more specific testing procedures for conducting 10-d toxicity tests with the amphipod Hyalella azteca and the midge Chironomus tentans. Toxicity endpoints measured in these tests are survival for H. azteca and survival and growth for C. tentans. Guidance has also been developed for conducting 28-d bioaccumulation tests with the oligochaete Lumbriculus variegatus, including determination of bioaccumulation kinetics for different compound classes. These methods have been applied to a variety of sediments to address issues ranging from site assessments to bioavailability of organic and inorganic contaminants using field-collected and laboratory-spiked samples. Survival and growth of controls routinely meet or exceed test acceptability criteria. Results of laboratory bioaccumulation studies with L. variegatus have been confirmed with comparisons to residues (PCBs, PAHs, DDT) present from synoptically collected field populations of oligochaetes. Additional method development is currently underway to develop chronic toxicity tests and to provide additional data-confirming responses observed in laboratory sediment tests with natural benthic populations.

  1. Comparison of food safety cognitions and self-reported food-handling behaviors with observed food safety behaviors of young adults.

    PubMed

    Abbot, J M; Byrd-Bredbenner, C; Schaffner, D; Bruhn, C M; Blalock, L

    2009-04-01

    Developing tailored and effective food safety education for young adults is critical given their future roles as caregivers likely to be preparing food for populations who may be at greater risk for foodborne disease (FBD). The objective of this study was to examine the relationship between food safety self-reported food-handling behaviors and cognitions of young adults to observed food-handling behaviors. Participants were 153 young adults (mean age 20.74+/-1.30 s.d.) attending a major American university. Each prepared a meal under observation in a controlled laboratory setting, permitted researchers to observe their home kitchen and completed an online survey assessing food safety knowledge, behavior and psychosocial measures. Descriptive statistics were generated for participants' self-reported food-handling behaviors, psychosocial characteristics, knowledge, food preparation observations and home kitchen observations. Determinants of compliance with safe food-handling procedures while preparing a meal and home food storage/rotation practices were identified using backward regression models. Participants engaged in less than half of the recommended safe food-handling practices evaluated and correctly answered only two-thirds of the food safety knowledge items. They reported positive food safety beliefs and high food safety self-efficacy. Self-reported compliance with cross-contamination prevention, disinfection procedures and knowledge of groups at greatest risk for FBD were the best measures for predicting compliance with established safe food-handling practices. Food safety education directed toward young adults should focus on increasing awareness of FBD and knowledge of proper cross-contamination prevention procedures to help promote better compliance with actual safe food handling.

  2. Non-invasive biomonitoring for PFRs and PBDEs: new insights in analysis of human hair externally exposed to selected flame retardants.

    PubMed

    Kucharska, Agnieszka; Covaci, Adrian; Vanermen, Guido; Voorspoels, Stefan

    2015-02-01

    In this study, we investigated the hypothesis whether externally adsorbed and internally deposited flame retardants (FRs) in hair could be distinguished. To this extent, hair samples collected from one volunteer were exposed under controlled conditions to phosphate FR (PFR) and polybrominated diphenyl ether (PBDE) standards to mimic external contamination. Afterwards, suitable washing procedures to selectively remove contaminants from the hair surface were investigated. The samples were measured by GC-(ECNI)-MS for PBDEs and LC-(ESI+)-MS/MS for PFRs. All investigated compounds were transferred onto the hair surface. One of the most important finding was that dust particles are not mandatory to transfer compounds on the hair surface and to be able to measure high levels of compounds in human hair. To assess different protocols to selectively remove external contamination, the exposed hair samples were washed in different media before analysis: water, methanol, hexane:dichloromethane (1:1, v/v), acetone and shampoo. Results indicated that there is no washing medium able to entirely and exclusively remove external contamination. Among investigated media, methanol removed a meaningful part of the external contamination (42-105%), but the removal efficiencies differed among compounds. We therefore concluded that hair should not be washed prior to analysis and in case of visible contamination (e.g. with cosmetic products), water would be the recommended agent. Organic solvents should not be used for the washing step. Although it is impossible to distinguish external from internal exposure, hair samples may be used as valuable biomarker of human exposure, providing a measure of integral exposure. To the best of our knowledge, this is the first study which has used externally exposed hair samples to PBDEs and PFRs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Moisture contamination and welding parameter effects on flux cored arc welding diffusible hydrogen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefer, J.J.

    1994-12-31

    Gas metal arc (GMAW) and flux cored arc (FCAW) welding are gas shielded semiautomatic processes widely used for achieving high productivity in steel fabrication. Contamination of the shielding has can occur due to poorly maintained gas distribution systems. Moisture entering as a gas contaminant is a source of hydrogen that can cause delayed cold cracking in welds. Limiting heat-affected zone hardness is one method of controlling cracking. Even this is based on some assumptions about the hydrogen levels in the weld. A study was conducted to investigate the effect of shielding gas moisture contamination and welding parameters on the diffusiblemore » hydrogen content of gas shielded flux cored arc welding. The total wire hydrogen of various electrodes was also tested and compared to the diffusible weld hydrogen. An empirical equation has been developed that estimates the diffusible hydrogen in weld metal for gas shielded flux cored arc welding. The equation is suitable for small diameter electrodes and welding parameter ranges commonly used for out-of-position welding. by combining this with the results from the total wire hydrogen tests, it is possible to estimate diffusible hydrogen directly from measured welding parameters, shielding gas dew point, and total hydrogen of the consumable. These equations are also useful for evaluating the effect of welding procedure variations from known baseline conditions.« less

  4. Effect of gingival fluid on marginal adaptation of Class II resin-based composite restorations.

    PubMed

    Spahr, A; Schön, F; Haller, B

    2000-10-01

    To evaluate in vitro the marginal quality of Class II composite restorations at the gingival enamel margins as affected by contamination of the cavities with gingival fluid (GF) during different steps of resin bonding procedures. 70 Class II cavities were prepared in extracted human molars and restored with composite using a multi-component bonding system (OptiBond FL/Herculite XRV; OPTI) or a single-bottle adhesive (Syntac Sprint/Tetric Ceram; SYN). The cavities were contaminated with human GF: C1 after acid etching, C2 after application of the primer (OPTI) or light-curing of the primer-adhesive (SYN), and C3 after light-curing of the resin adhesive (OPTI). Uncontaminated cavities were used as the control (C0). The restored teeth were subjected to thermocycling (TC) and replicated for SEM analysis of marginal gap formation. Microleakage at the gingival margins was determined by dye penetration with basic fuchsin. non-parametric tests (Kruskal-Wallis test, Mann-Whitney test with Bonferroni correction). In both bonding systems, contamination with GF after acid etching (C1) did not impair the marginal quality; the mean percentages of continuous margin/mean depths of dye penetration were: OPTI: C0: 88.5%/0.10 mm, C1: 95.6%/0.04 mm; SYN: C0: 90.9%/0.08 mm, C1: 97.0%/0.05 mm. Marginal adaptation was adversely affected when GF contamination was performed after

  5. Serotypes and Pulsotypes diversity of Listeria monocytogenes in a beef-processing environment.

    PubMed

    Camargo, Anderson Carlos; Dias, Mariane Rezende; Cossi, Marcus Vinícius Coutinho; Lanna, Frederico Germano Piscitelli Alvarenga; Cavicchioli, Valéria Quintana; Vallim, Deyse Christina; Pinto, Paulo Sérgio de Arruda; Hofer, Ernesto; Nero, Luís Augusto

    2015-04-01

    Utensils and equipment from meat-processing facilities are considered relevant cross-contamination points of Listeria monocytogenes to foods, demanding tracking studies to identify their specific origins, and predict proper control. The present study aimed to detect L. monocytogenes in a beef-processing facility, investigating the diversity of serotypes and pulsotypes in order to identify the possible contamination routes. Surface samples from knives (n=26), tables (n=78), and employees hands (n=74) were collected before and during the procedures from a beef-processing facility, in addition to surface samples of end cuts: round (n=32), loin (n=30), and chuck (n=32). All samples were subjected to L. monocytogenes screening according ISO 11.290-1, and the obtained isolates were subjected to serotyping and pulsed-field gel electrophoresis. Listeria spp. were identified in all processing steps, in 61 samples, and L. monocytogenes was detected in 17 samples, not being found only in knives. Eighty-five isolates were identified as L. monocytogenes, from serotypes 1/2c (n=65), 4b (n=13), and 1/2b (n=7), being grouped in 19 pulsotypes. Considering these results, cross-contamination among hands, tables, and beef cuts could be identified. The obtained data indicated the relevance of cross-contamination in the beef-processing facility, and the occurrence of serotypes 1/2b and 4b in beef cuts distributed for retail sale is a public health concern.

  6. Internal contamination in the space station

    NASA Technical Reports Server (NTRS)

    Poythress, C.

    1985-01-01

    Atmosphere trace contaminant control systems used in the past (Lunar Module and Skylab) and present (nuclear submarines and Shuttle) are discussed. Recommendations are made for the future Space Station contaminant control system. The prevention and control methods used are judicious material selection, detection, and specific removal equipment. Sources and effects of contamination relating to crew and equipment are also discussed.

  7. Antibiotic prophylaxis audit and questionnaire study: Traffic Light Poster improves adherence to protocol in gastrointestinal surgery.

    PubMed

    Cameron, Michaella; Jones, Stacey; Adedeji, Olufunso

    2015-07-01

    To measure adherence to antibiotic prophylaxis (AP) protocol amongst surgeons and anesthetists and explore their understanding of AP prescribing in practice. A prospective audit of AP in gastrointestinal surgery and re-audit after intervention. A questionnaire survey of practice. 58 (38%- clean; 62%- clean contaminated) operations were audited and 73 (48%-clean; 51%-clean contaminated) operations were re-audited after intervention with "Traffic Light Poster" (TFP) .55 colleagues (32 consultants and 23 trainees) were recruited for questionnaire survey in three West Midlands hospitals. Audit and Re-Audits. Only 31% of procedures followed the protocol correctly in the initial audit and this increased to 73% in the re-audit. 73% of patients undergoing clean procedures received AP inappropriately in the initial audit but reduced significantly to 20% (p < 0.002) in the re-audit. In the initial audit, 62% of clean contaminated procedures did not receive the appropriate first line AP but this fell to 35% (p < 0.05) in the re-audit. Questionnaire Survey- Only 30% of respondents would not give AP in clean surgery as recommended. 45% would use appropriate AP for clean-contaminated wounds. 73% of respondents will give AP at induction, 20% 1 h pre op and 7% just before incision. There is poor compliance with AP protocols in gastrointestinal surgery in part due to general lack of awareness. An educational intervention in the form of a 'Traffic Light Poster' improved adherence to AP protocol two fold. There was improved rationalizing of AP. Clean procedures, in particular, had less inappropriate prescribing. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  8. Assessment of a handheld fluorescence imaging device as a visual-aid for detection of food residues on processing surfaces

    USDA-ARS?s Scientific Manuscript database

    Contamination of food with pathogenic bacteria can lead to foodborne illnesses. Food processing surfaces can serve as a medium for cross-contamination if sanitization procedures are inadequate. Ensuring that food processing surfaces are correctly cleaned and sanitized is important in the food indust...

  9. Evaluation of a Low-Cost Commercially Available Extraction Device for Assessing Lead Bioaccessibility in Contaminated Soils

    EPA Science Inventory

    The U.S. EPA’s in vitro bioaccessibility (IVBA) method 9200.1-86 defines a validated analytical procedure for the determination of lead bioaccessibility in contaminated soils. The method requires the use of a custom-fabricated extraction device that uses a heated water bath for ...

  10. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (5) Loss of water supply is not a basis for assistance under this authority. (6) Water will not be... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Emergency water supplies due to... PROCEDURES Emergency Water Supplies: Contaminated Water Sources and Drought Assistance § 203.61 Emergency...

  11. 9 CFR 113.28 - Detection of mycoplasma contamination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REQUIREMENTS Standard Procedures § 113.28 Detection of mycoplasma contamination. The heart infusion test, using heart infusion broth and heart infusion agar, provided in this section shall be conducted when a test... inactivated at 56 °C for 30 minutes. (b) Heart infusion broth shall be prepared as provided in this paragraph...

  12. COMPARISON OF THE TEMPORAL VARIABILITY OF ENTEROCOCCAL CLUSTERS IN IMPACTED STREAMS USING A MULTIPLEX POLYMERASE CHAIN REACTION PROCEDURE

    EPA Science Inventory

    Understanding how fecal indicator bacteria and/or fecal indicator genotypes vary over time is important to determine the sources of fecal contamination. Enterococcus is one of the two indicators recommended by the EPA to monitor freshwaters for fecal contamination. Along with E...

  13. Laboratory, Field, and Analytical Procedures for Using Passive Sampling in the Evaluation of Contaminated Sediments: User's Manual

    EPA Science Inventory

    Regardless of the remedial technology invoked to address contaminated sediments in the environment, there is a critical need to have tools for assessing the effectiveness of the remedy. In the past, these tools have included chemical and biomonitoring of the water column and sedi...

  14. 50 CFR 260.103 - Operations and operating procedures shall be in accordance with an effective sanitation program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cause contamination of foods by oil, dust, paint, scale, fumes, grinding materials, decomposed food... partially processed food ingredients shall not be stacked in such manner as to permit contamination of the... PROCESSED FISHERY PRODUCTS, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS INSPECTION...

  15. COMPARISON OF TWO FIELD SAMPLING PROCEDURES (EN CORE AND FIELD METHANOL EXTRACTION) FOR VOLATILE ORGANIC COMPOUNDS

    EPA Science Inventory

    In-situ Lasagna technology was recently evaluated at a contaminated site at Offutt Air Force Base. The site was contaminated with low levels (< 30 mg/kg) of volatile organic compounds (VOCs). Originally, researchers planned to use field methanol extraction for both pre- and pos...

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, S.R.

    A comprehensive evaluation was conducted of the radiation protection practices and programs at prototype LMFBRs with long operational experience. Installations evaluated were the Fast Flux Test Facility (FFTF), Richland, Washington; Experimental Breeder Reactor II (EBR-II), Idaho Falls, Idaho; Prototype Fast Reactor (PFR) Dounreay, Scotland; Phenix, Marcoule, France; and Kompakte Natriumgekuhlte Kernreak Toranlange (KNK II), Karlsruhe, Federal Republic of Germany. The evaluation included external and internal exposure control, respiratory protection procedures, radiation surveillance practices, radioactive waste management, and engineering controls for confining radiation contamination. The theory, design, and operating experience at LMFBRs is described. Aspects of LMFBR health physics different frommore » the LWR experience in the United States are identified. Suggestions are made for modifications to the NRC Standard Review Plan based on the differences.« less

  17. A proposed method to minimize waste from institutional radiation safety surveillance programs through the application of expected value statistics.

    PubMed

    Emery, R J

    1997-03-01

    Institutional radiation safety programs routinely use wipe test sampling and liquid scintillation counting analysis to indicate the presence of removable radioactive contamination. Significant volumes of liquid waste can be generated by such surveillance activities, and the subsequent disposal of these materials can sometimes be difficult and costly. In settings where large numbers of negative results are regularly obtained, the limited grouping of samples for analysis based on expected value statistical techniques is possible. To demonstrate the plausibility of the approach, single wipe samples exposed to varying amounts of contamination were analyzed concurrently with nine non-contaminated samples. Although the sample grouping inevitably leads to increased quenching with liquid scintillation counting systems, the effect did not impact the ability to detect removable contamination in amounts well below recommended action levels. Opportunities to further improve this cost effective semi-quantitative screening procedure are described, including improvements in sample collection procedures, enhancing sample-counting media contact through mixing and extending elution periods, increasing sample counting times, and adjusting institutional action levels.

  18. Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants

    USGS Publications Warehouse

    Petty, J.D.; Orazio, C.E.; Huckins, J.N.; Gale, R.W.; Lebo, J.A.; Meadows, J.C.; Echols, K.R.; Cranor, W.L.

    2000-01-01

    Semipermeable membrane devices (SPMDs) are used with increasing frequency, and throughout the world as samplers of organic contaminants. The devices can be used to detect a variety of lipophilic chemicals in water, sediment/soil, and air. SPMDs are designed to sample nonpolar, hydrophobic chemicals. The maximum concentration factor achievable for a particular chemical is proportional to its octanol–water partition coefficient. Techniques used for cleanup of SPMD extracts for targeted analytes and for general screening by full-scan mass spectrometry do not differ greatly from techniques used for extracts of other matrices. However, SPMD extracts contain potential interferences that are specific to the membrane–lipid matrix. Procedures have been developed or modified to alleviate these potential interferences. The SPMD approach has been demonstrated to be applicable to sequestering and analyzing a wide array of environmental contaminants including organochlorine pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polychlorinated dioxins and dibenzofurans, selected organophosphate pesticides and pyrethroid insecticides, and other nonpolar organic chemicals. We present herein an overview of effective procedural steps for analyzing exposed SPMDs for trace to ultra-trace levels of contaminants sequestered from environmental matrices.

  19. Report: EPA Has Made Progress in Assessing Historical Lead Smelter Sites But Needs to Strengthen Procedures

    EPA Pesticide Factsheets

    Report #14-P-0302, June 17, 2014. Improvements in guidance and procedures for managing contaminated sites could result in more efficient and effective use of limited resources and result in public health and economic benefits.

  20. 10 CFR 39.63 - Operating and emergency procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.63 Operating and emergency procedures. Each licensee shall develop and... radiation surveys, including surveys for detecting contamination, as required by § 39.67(c)-(e); (d...

  1. 10 CFR 39.63 - Operating and emergency procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.63 Operating and emergency procedures. Each licensee shall develop and... radiation surveys, including surveys for detecting contamination, as required by § 39.67(c)-(e); (d...

  2. 10 CFR 39.63 - Operating and emergency procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.63 Operating and emergency procedures. Each licensee shall develop and... radiation surveys, including surveys for detecting contamination, as required by § 39.67(c)-(e); (d...

  3. 10 CFR 39.63 - Operating and emergency procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.63 Operating and emergency procedures. Each licensee shall develop and... radiation surveys, including surveys for detecting contamination, as required by § 39.67(c)-(e); (d...

  4. 10 CFR 39.63 - Operating and emergency procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.63 Operating and emergency procedures. Each licensee shall develop and... radiation surveys, including surveys for detecting contamination, as required by § 39.67(c)-(e); (d...

  5. Development of a preprototype trace contaminant control system. [for space stations

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The steady state contaminant load model based on shuttle equipment and material test programs, and on the current space station studies was revised. An emergency upset contaminant load model based on anticipated emergency upsets that could occur in an operational space station was defined. Control methods for the contaminants generated by the emergency upsets were established by test. Preliminary designs of both steady state and emergency contaminant control systems for the space station application are presented.

  6. Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy

    PubMed Central

    Peters, Frans T. M.; van der Mei, Henny C.; Degener, John E.

    2013-01-01

    SUMMARY Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection. PMID:23554415

  7. Laboratory Methods for the Measurement of Pollutants in Water and Waste Effluents

    NASA Technical Reports Server (NTRS)

    Ballinger, Dwight G.

    1971-01-01

    The requirement for accurate, precise, and rapid analytical procedures for the examination of water and waste samples requires the use of a variety of instruments. The instrumentation in water laboratories includes atomic absorption, UV-visible. and infrared spectrophotometers, automatic colorimetric analyzers, gas chromatographs and mass spectrometers. Because of the emphasis on regulatory action, attention is being directed toward quality control of analytical results. Among the challenging problems are the differentiation of metallic species in water at nanogram concentrations, rapid measurement of free cyanide and free ammonia, more sensitive methods for arsenic and selenium and improved characterization of organic contaminants.

  8. Contamination during criminal investigation: Detecting police contamination and secondary DNA transfer from evidence bags.

    PubMed

    Fonneløp, Ane Elida; Johannessen, Helen; Egeland, Thore; Gill, Peter

    2016-07-01

    As the profiling systems used in forensic analyses have become more sensitive in recent years, the risk of detecting a contamination in a DNA sample has increased proportionally. This requires more stringent work protocols and awareness to minimize the chance of contamination. Although there is high consciousness on contamination and best practice procedures in forensic labs, the same requirements are not always applied by the police. In this study we have investigated the risk of contamination from police staff. Environmental DNA was monitored by performing wipe tests (sampling of hot spots) at two large police units (scenes of crime departments). Additionally, the DNA profiles of the scenes of crime officers were compared to casework samples that their own unit had investigated in the period of 2009-2015. Furthermore, a pilot study to assess whether DNA from the outside package of an exhibit could be transferred to a DNA sample was carried out. Environmental DNA was detected in various samples from hot spots. Furthermore, 16 incidences of previously undetected police-staff contamination were found in casework that had been submitted between 2009 and 2015. In 6 cases the police officers with a matching DNA profile reported that they had not been involved with the case. We have demonstrated that DNA from the outside package can be transferred to an exhibit during examination. This experience demonstrates that when implementing the new multiplex systems, it is important to ensure that 'best practice' procedures are upgraded, and appropriate training is provided in order to ensure that police are aware of the increased contamination risks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andre, M.; Hugot, G.

    A procedure is described for the detection of alpha -emitting contaminants of the respiratory tract. The method is useful when contamination from inhaled Pu/sup 239/ is suspected. Sputum, collected early in the morning, is dissolved in mineral acids and then evaporated on a stainiess steel plate. Radioautograms are prepared by placing the plate in contact with a nuclear emulsion. The number of tracks appearing after 24 and 48 hrs and 7 days is counted. The results are useful in estimating internal contamination and in following removal from the respiratory tract. (C.H.)

  10. Final Quality Assurance Plan for the Remedial Investigations and Feasibility Studies of the Helicopter Hangar Area and the Fire Training Area at Fort George G. Meade, Maryland

    DTIC Science & Technology

    1995-05-05

    impoundment for a metal products manufacturer in Florida. During the site investigation, evidence of offsite contamination was found to be migrating onto...equipment, cross contamination through improper storage of samples) " Audit sampling documentation and procedures to ensure that samples are labeled...characterization of the occurrence and distribution of chemical contamination and site characteristics that are likely to influence human exposure or remediation

  11. Shuttle filter study. Volume 3: Appendix

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Test data obtained from flow resistance and contaminant tolerance tests on the various porous media evaluated in the different fluids are presented in both graphical and tabular forms. Test procedures for both flow resistance and contaminant tolerance testing are presented, and the development of a system for continuously adding contaminant at a predetermined rate to a flowing fluid stream is described. Also included is a section describing the development effort of the self-indexing filter. This concept was adapted during this program for various shuttle applications.

  12. Quality assessment of trace Cd and Pb contaminants in Thai herbal medicines using ultrasound-assisted digestion prior to flame atomic absorption spectrometry.

    PubMed

    Siriangkhawut, Watsaka; Sittichan, Patcharee; Ponhong, Kraingkrai; Chantiratikul, Piyanete

    2017-10-01

    A simple, efficient, and reliable ultrasound-assisted digestion (UAD) procedure was used for sample preparation prior to quantitative determination of trace Cd and Pb contaminants in herbal medicines using flame atomic absorption spectrometry. The parameters influencing UAD such as the solvent system, sample mass, presonication time, sonication time, and digestion temperature were evaluated. The efficiency of the proposed UAD procedure was evaluated by comparing with conventional acid digestion (CAD) procedure. Under the optimum conditions, linear calibration graphs in a range of 2-250 μg/L for Cd, and 50-1000 μg/L for Pb were obtained with detection limits of 0.56 μg/L and 10.7 μg/L for Cd and Pb, respectively. The limit of quantification for Cd and Pb were 1.87 μg/L and 40.3 μg/L, respectively. The repeatability for analysis of 10 μg/L for Cd and 100 μg/L for Pb was 2.3% and 2.6%, respectively. The accuracy of the proposed method was evaluated by rice flour certified reference materials. The proposed method was successfully applied for analysis of trace Cd and Pb in samples of various types of medicinal plant and traditional medicine consumed in Thailand. Most herbal medicine samples were not contaminated with Cd or Pb. The contaminant levels for both metals were still lower than the maximum permissible levels of elements in medicinal plant materials and finished herbal products sets by the Ministry of Public Health of Thailand. The exception was the high level of Cd contamination found in two samples of processed medicinal plants. Copyright © 2017. Published by Elsevier B.V.

  13. Environmental and biological monitoring of platinum-containing drugs in two hospital pharmacies using positive air pressure isolators.

    PubMed

    Kopp, Bettina; Crauste-Manciet, Sylvie; Guibert, Agnès; Mourier, Wilhelmine; Guerrault-Moro, Marie-Noelle; Ferrari, Sylvie; Jomier, Jean-Yves; Brossard, Denis; Schierl, Rudolf

    2013-04-01

    Environmental and biological monitoring of platinum containing drugs was implemented in two French hospital pharmacies using positive air pressure isolators and having similar working procedures when preparing antineoplastic drugs. Wipe sampling of surfaces, gloves, and vials was performed in the preparation room and in storage areas. All employees involved in the preparation of antineoplastic drugs were tested for urinary platinum on Monday before work and Friday after shift. Only traces of platinum were detected on surfaces in the preparation room outside the isolators (less than 1.61 pg cm(-2)). However, in one center, significant contamination was found in the storage area of the drug vials, which can most likely be linked to the rupture of a platinum vial and due to inefficient cleaning procedures. Surfaces inside the isolators were found to be contaminated (maximum: 198.4 pg cm(-2)). A higher level of contamination was detected in one pharmacy and could be explained by the lack of overgloving with regular changes during the preparation process. Nitrile gloves used during drug handling outside the isolator showed the highest platinum concentration (maximum: 5.86 ng per pair). With regards to platinum urine concentration, no significant difference was found between exposed and unexposed pharmacy personnel. Isolator technology combined with individual protective measures seems to be efficient to protect workers from occupational exposure to antineoplastic drugs, whereas specific individual protective procedures implemented were focussing on the risk of handling vials outside the isolator (e.g. high frequency of glove changing). Moreover, overgloving inside the isolator would contribute to substantially decrease inner surface contamination and should be recommended in order to limit the transfer of chemical contamination to the end products.

  14. Development of a sorber trace contaminant control system including pre- and post-sorbers for a catalytic oxidizer

    NASA Technical Reports Server (NTRS)

    Olcott, T. M.

    1972-01-01

    A general methodology was developed for spacecraft contaminant control system design. Elements considered for contaminant control were catalytic oxidation with isotope or electrical heat and pre- and post-sorbers, charcoal with regeneration and non-regeneration, and reactive constituents. A technique is described for sizing a charcoal bed for a multiple contaminant load.

  15. Virus elimination during the recycling of chromatographic columns used during the manufacture of coagulation factors.

    PubMed

    Roberts, Peter L

    2014-07-01

    Various chromatographic procedures are used during the purification and manufacture of plasma products such as coagulation factors. These steps contribute to the overall safety of such products by removing potential virus contamination. Virus removal by two affinity chromatography procedures, i.e. monoclonal antibody chromatography and metal chelate chromatography (immobilised metal ion affinity chromatography), used during the manufacture of the high purity factor VIII (Replenate®) and factor IX (Replenine®-VF), respectively, has been investigated. In addition, as these columns are recycled after use, the effectiveness of the sanitisation procedures for preventing possible cross-contamination, has also been investigated. Both chromatographic steps proved effective for eliminating a range of model enveloped and non-enveloped viruses by 4 to >6 and 5 to >8 log for the monoclonal and metal chelate columns, respectively. The effectiveness of the relatively mild column sanitisation conditions used, i.e. ethanol for factor IX and acetic acid for factor VIII, was confirmed using non-spiked column runs. The chemicals used contributed to virus elimination by inactivation and/or by physical removal of the virus. In summary, these studies demonstrate that potential virus contamination between chromatographic runs can be prevented when an effective column recycling and sanitisation procedure is included. Copyright © 2014 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  16. Sampling of resident earthworms using mustard expellant to evaluate ecological risk at a mixed hazardous and radioactive waste site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stair, D.M. Jr.; Keller, L.J.; Hensel, T.W.

    1994-12-31

    As residents of contaminated soils and as prey for many species of wildlife, earthworms can serve as integrative biomonitors of soil contamination, which is biologically available to the terrestrial food chain. The assessment of contaminants within earthworm tissue provides a more realistic measurement of the potential biological hazards and ecological risks than physical and chemical measurements of soil. A unique sampling procedure using a mixture of ground mustard powder and water was implemented for cost-effectively collecting earthworms without digging; the procedure minimized occupational exposure to soil contaminants and reduced the quantity of investigation-derived wastes. The study site is located atmore » a closed burial ground for low-level radioactive waste and transuranic waste that lies within the Valley and Ridge Physiographic Province of East Tennessee. Earthworms were maintained in the laboratory for four days to allow passage of the contents of the digestive tract. Earthworm body burdens, castings, and soil were analyzed for gamma-emitting radioisotopes (potassium 40, cobalt 60, cesium 137), strontium 90, trace metals (arsenic, cadmium, chromium, mercury, lead, and selenium), and polychlorinated biphenyls (PCBs). Ecological effects of soil contamination on the earthworms were also assessed through analysis of weight, abundance, and reproductive success.« less

  17. Evidence-based value of subcutaneous surgical wound drainage: the largest systematic review and meta-analysis.

    PubMed

    Kosins, Aaron M; Scholz, Thomas; Cetinkaya, Mine; Evans, Gregory R D

    2013-08-01

    The purpose of this study was to determine the evidenced-based value of prophylactic drainage of subcutaneous wounds in surgery. An electronic search was performed. Articles comparing subcutaneous prophylactic drainage with no drainage were identified and classified by level of evidence. If sufficient randomized controlled trials were included, a meta-analysis was performed using the random-effects model. Fifty-two randomized controlled trials were included in the meta-analysis, and subgroups were determined by specific surgical procedures or characteristics (cesarean delivery, abdominal wound, breast reduction, breast biopsy, femoral wound, axillary lymph node dissection, hip and knee arthroplasty, obesity, and clean-contaminated wound). Studies were compared for the following endpoints: hematoma, wound healing issues, seroma, abscess, and infection. Fifty-two studies with a total of 6930 operations were identified as suitable for this analysis. There were 3495 operations in the drain group and 3435 in the no-drain group. Prophylactic subcutaneous drainage offered a statistically significant advantage only for (1) prevention of hematomas in breast biopsy procedures and (2) prevention of seromas in axillary node dissections. In all other procedures studied, drainage did not offer an advantage. Many surgical operations can be performed safely without prophylactic drainage. Surgeons can consider omitting drains after cesarean section, breast reduction, abdominal wounds, femoral wounds, and hip and knee joint replacement. Furthermore, surgeons should consider not placing drains prophylactically in obese patients. However, drain placement following a surgical procedure is the surgeon's choice and can be based on multiple factors beyond the type of procedure being performed or the patient's body habitus. Therapeutic, II.

  18. How-to-Do-It: A Simple DNA Isolation Technique Using Halophilic Bacteria.

    ERIC Educational Resources Information Center

    Guilfoile, Patrick

    1989-01-01

    Described is a simple technique for isolating DNA from halophilic bacteria. Materials, procedure, and additional experiments are outlined. It is stated that the DNA obtained will be somewhat contaminated with cellular proteins and RNA. Offers a procedure for greater purification. (RT)

  19. Evaluation of a cleanser for petroleum-contaminated skin.

    PubMed

    Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin

    2003-12-01

    Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.

  20. Procedures involving lipid media for detection of bacterial contamination in breweries.

    PubMed

    Van Vuuren, H J; Louw, H A; Loos, M A; Meisel, R

    1977-02-01

    The liquid equivalent of universal beer agar, designated universal beer liquid medium, and its beer-free equivalent, universal liquid medium (UL), were equally effective in demonstrating bacterial contamination in 120 of 200 samples from different stages of commercial brewing process. Growth of the contaminants after 3 days was consistently more luxuriant in the UL medium. A yeast-water substrate medium failed to reveal many contaminants detected with UL in 392 samples from three breweries and revealed only a few not detected with UL. The use of UL and a lactose-peptone medium, with microscope examination of the media for bacterial growth, permitted detection of 93% of the known contaminants compared to 87%, detected with UL alone; this combination or universal beer liquid medium plus lactose-peptone medium can therefore be recommended for the detection of bacterial contaminants in brewery samples. Bacterial contamination of pitching yeasts appeared to be a particular problem in the breweries investigated.

  1. Chemical immobilization of Pb, Cu, and Cd by phosphate materials and calcium carbonate in contaminated soils.

    PubMed

    Huang, Guoyong; Su, Xiaojuan; Rizwan, Muhammad Shahid; Zhu, Yifei; Hu, Hongqing

    2016-08-01

    Soil contamination with toxic metals has increasingly become a global concern over the past few decades. Phosphate and carbonate compounds are good passivation materials for Pb immobilization, while the effect of phosphate and carbonate on the immobilization of multiple heavy metals (Pb, Cu, and Cd) in contaminated soils was seldom investigated. In this study, bone meal (BM), phosphate rock (PR), oxalic acid-activated phosphate rock (APR), super phosphate (SP), and calcium carbonate (CC) were added to the contaminated soils to evaluate the effect of phosphate materials and calcium carbonate on the immobilization of Pb, Cu, and Cd. The results showed that the pH of the treated soils increased 1.3-2.7, except SP which decreased 0.5 at most. Compared to the control treatment, all phosphates and calcium carbonate added to the polluted soils increased the fraction of residual metals, and the application of APR, PR, BM, and CC significantly reduced exchangeable and carbonate-bound fraction metals. PR and APR were the most effective for the immobilization of Pb, Cu, and Cd in the soils among these materials. Moreover, the concentrations of all metals in the toxicity characteristic leaching procedure (TCLP) leachate decreased with increasing amounts of amendments, and the concentrations of Pb in the TCLP leachate for soils treated with PR and APR were below the nonhazardous regulatory limit of 5 mg L(-1) (US Environmental Protection Agency). Based on our results, phosphate rock and oxalic acid-activated phosphate rock are effective in the immobilization of multiple metals by reducing their mobility in the co-contaminated soils.

  2. Salmonella and produce: survival in the plant environment and implications in food safety.

    PubMed

    Fatica, Marianne K; Schneider, Keith R

    2011-01-01

    There has been a continuous rise in the number of produce-based foodborne outbreaks in the recent decades despite the perception that foodborne diseases were primarily linked to animal-based products. The Centers for Disease Control and Prevention (CDC) estimates that 95% of Salmonella-based infections originate from foodborne sources, with multiple produce-based salmonellosis outbreaks occurring since 1990. The contamination of produce in both the pre-harvest and post-harvest produce environments is challenging to eliminate since produce is consumed as a raw, fresh commodity. Salmonella spp. contamination is possible through contact with the produce in the field as well as in the processing facility. The field contamination of produce infers the ability of Salmonella spp. to survive on the plant surface. The fitness of Salmonella spp. in the plant habitat is limited as opposed to naturally plant-associated bacteria, but survival is possible. The use of intensive farming practices, globalization of food products, high demand for convenience food products, and increased foodborne disease surveillance also have unknown ramifications in the ascending trends of produce-based outbreaks. A better understanding of the ecology of Salmonella spp. in the plant environment as well as the processing, food handling, and surveillance factors affecting the incidence of foodborne outbreaks will provide a comprehensive view of the etiology and epidemiology of produce-associated foodborne outbreaks. An understanding of the outbreaks and the factors facilitating produce contamination will allow for the development of intervention procedures and strategies to reduce the risk of produce contamination by Salmonella spp.

  3. The effect of storage conditions, contamination modes and cleaning procedures on the resin bond strength to lithium disilicate ceramic.

    PubMed

    Klosa, Karsten; Wolfart, Stefan; Lehmann, Frank; Wenz, Hans-Jürgen; Kern, Matthias

    2009-04-01

    The purpose of this in-vitro study was to evaluate the resin bond strength to pre-etched lithium disilicate ceramic using different cleaning methods after two contamination modes (saliva or saliva and silicone). Plexiglas tubes filled with composite resin (MultiCore Flow) were bonded to etched and silanized ceramic disks made of lithium disilicate ceramic (IPS e.max Press) using a luting resin (Multilink Automix). Either etched or unetched ceramic surfaces were contaminated with saliva or with saliva followed by a disclosing silicone. Groups of 16 specimens each were bonded after pretreatment using 4 surface cleaning agents (37% phosphoric acid, 5% hydrofluoric acid, 96% isopropanol, air polishing device with sodium bicarbonate) in different combinations. Before measuring tensile bond strength, specimens were stored for 3 or 150 days with thermocycling. After 150 days of storage, etching of saliva-contaminated surfaces with 5% hydrofluoric acid and/or 37% phosphoric acid provided statistically significantly higher bond strengths (37.9 to 49.5 MPa) than the other cleaning methods (1.7 to 15.5 MPa). After saliva and silicone contamination, etching with 5% hydrofluoric acid provided statistically significantly higher bond strengths (44.5 to 50.3 MPa) than all other cleaning methods (0.3 to 13.5 MPa). Ceramic cleaning methods after try-in procedures have a significant influence on the resin bond strength and are dependent on the type of contamination. Re-etching lithium disilicate ceramic with 5% hydrofluoric acid is most effective in removing contamination with saliva and/or a silicone disclosing medium.

  4. Requirements and Sizing Investigation for Constellation Space Suit Portable Life Support System Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.; Jennings, Mallory A.; Waguespack, Glenn

    2010-01-01

    The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Constellation Space Suit Portable Life Support System (PLSS), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for Constellation Space Suit System (CSSS) pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

  5. Ozone contamination in aircraft cabins - Results from GASP data and analyses

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Nastrom, G. D.

    1981-01-01

    The paper reviews results from the NASA Global Atmospheric Sampling Program (GASP) pertaining to the problem of ozone contamination in commercial aircraft cabins. Specifically, analyses of GASP data have (1) confirmed the high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; (2) defined ambient ozone climatology at commercial aircraft cruise altitudes, including tabulation of encounter frequency data; and (3) outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data and verified these procedures against cabin measurements.

  6. Ozone contamination in aircraft cabins: Results from GASP data and analyses

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Nastrom, G. D.

    1981-01-01

    The global atmospheric sampling program pertaining to the problem of ozone contamination in commercial airplane cabins is described. Specifically, analyses of GASP data have: confirmed the occurrence of high ozone levels in aircraft cabins and documented the ratio of ozone inside and outside the cabins of two B747 airliners, including the effects of air conditioning modifications on that ratio; defined ambient ozone climatology at commercial airplane cruise altitudes, including tabulation of encounter frequency data which were not available before GASP; and outlined procedures for estimating the frequency of flights encountering high cabin ozone levels using climatological ambient ozone data, and verified these procedures against cabin measurements.

  7. Fungal flora and aflatoxin contamination in Pakistani wheat kernels (Triticum aestivum L.) and their attribution in seed germination.

    PubMed

    Asghar, Muhammad Asif; Ahmed, Aftab; Iqbal, Javed; Zahir, Erum; Nauman, Hina

    2016-07-01

    This study aimed to isolate fungal pathogens and to subsequently quantify aflatoxin (AF; B 1  + B 2  + G 1  + G 2 ) contamination in wheat crops grown in Pakistan. Accordingly, a total of 185 wheat samples were collected from different areas of Pakistan and numerous potent fungal pathogens were isolated. AF contamination attributed to the presence of intoxicating fungal pathogens and resulting metabolic activities were quantified using a high performance liquid chromatography-fluorescence detector coupled with postcolumn derivatization. Additionally, the effect of fungal pathogens on seed germination was also examined. The results obtained showed that 50% of tested wheat samples were found to be contaminated with a diverse range of fungal species. The rate of recurrence of fungal pathogens were Aspergillus 31%, Penicillium 9%, Fusarium 8%, Rhizopus 3%, and Alternaria 2%. The presence of Tilletia indica and Claviceps purpurea species was found to be inevident in all tested wheat samples. AFB 1 contamination was detected in 48 (26.0%) samples and AFB 2 in 13 (7.0%) samples. AFG 1 and AFG 2 were not found in any of the tested samples. The contamination range of AFB 1 and AFB 2 was 0.05-4.78 μg/kg and 0.02-0.48 μg/kg, respectively. The total amount of AFs (B 1  + B 2 ) found in 48 (26.0%) samples had a mean level of 0.53 ± 0.40 μg/kg and a contamination range of 0.02-5.26 μg/kg. The overall results showed that in 137 (74.0%) samples, AFs were not found within detectable limits. Furthermore, in 180 (97.2%) samples, AF levels were found to be below the maximum tolerated levels (MTL) recommended by the European Union (4 μg/kg). In five (2.7%) samples, AF contamination was higher than the MTL of the European Union. However, these samples were fit for human consumption with reference to the MTL (20 μg/kg) assigned by the USA (Food and Drug Administration and Food and Agriculture Organization) and Pakistan (Pakistan Standards and Quality Control Authority). Germination rates in healthy and contaminated wheat kernels were 84.6% and 45.2%, respectively. Based on the obtained results, it was concluded that the levels of fungal pathogen and AF contamination in Pakistani-grown wheat are not a potential threat to consumer health. However, control procedures along with a strict monitoring policy are mandatory to further minimize the prevalence of fungal carriers and the potency of AFs in crops cultivated in Pakistan. Copyright © 2016. Published by Elsevier B.V.

  8. Quality control for federal clean water act and safe drinking water act regulatory compliance.

    PubMed

    Askew, Ed

    2013-01-01

    QC sample results are required in order to have confidence in the results from analytical tests. Some of the AOAC water methods include specific QC procedures, frequencies, and acceptance criteria. These are considered to be the minimum controls needed to perform the method successfully. Some regulatory programs, such as those in 40 CFR Part 136.7, require additional QC or have alternative acceptance limits. Essential QC measures include method calibration, reagent standardization, assessment of each analyst's capabilities, analysis of blind check samples, determination of the method's sensitivity (method detection level or quantification limit), and daily evaluation of bias, precision, and the presence of laboratory contamination or other analytical interference. The details of these procedures, their performance frequency, and expected ranges of results are set out in this manuscript. The specific regulatory requirements of 40 CFR Part 136.7 for the Clean Water Act, the laboratory certification requirements of 40 CFR Part 141 for the Safe Drinking Water Act, and the ISO 17025 accreditation requirements under The NELAC Institute are listed.

  9. Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon.

    PubMed

    Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K

    2011-12-01

    Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.

  10. An update on methods for cryopreservation and thawing of hemopoietic stem cells.

    PubMed

    Lecchi, Lucilla; Giovanelli, Silvia; Gagliardi, Barbara; Pezzali, Ilaria; Ratti, Ilaria; Marconi, Maurizio

    2016-06-01

    The aim of this article is to review a number of variables that may affect the cryopreservation of minimally manipulated products containing allogeneic or autologous hemopoietic progenitor cells (HPC) used for transplantation, with particular reference to processing, type and addition of cryoprotectant, cell concentration, volume, freezing procedure, cooling rate, storage, thawing, and quality management. After defining final product's requirements in compliance with norms, laws and regulations, it is crucial to define the critical control points of the process. New approaches of processing were developed in the last few years such as automatic devices for volume reduction and high cell concentration in the frozen product. DMSO at 10% final concentration is still the most used cryoprotectant for HPC cryopreservation. Although controlled rate freezing is the recommended method for HPC cryopreservation, alternative methods may be used. Last generation vapor storage vessels ensure temperature stability better than older tanks. Their use may reduce risks of cross-contamination. Finally we review advantages and disadvantages of thawing procedures that may be carried out in the laboratory or at the patient's bedside. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Applications of aerospace technology in industry, a technology transfer profile: Contamination control

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The strong influence NASA-sponsored research has had on the development of solutions to difficult contamination problems is considered. The contamination control field is comprised of an industrial base, supplying the tools of control; a user base, adopting control techniques; and a technical base, expanding the concepts of control. Both formal and informal mechanisms used by NASA to communicate a variety of technical advances are reviewed and certain examples of the expansion of the user base through technology transfer are given. Issues related to transfer of NASA-generated contamination control technology are emphasized.

  12. Trace Contaminant Control for the International Space Station's Node 1- Analysis, Design, and Verification

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Trace chemical contaminant generation inside crewed spacecraft cabins is a technical and medical problem that must be continuously evaluated. Although passive control through materials selection and active control by adsorption and catalytic oxidation devices is employed during normal operations of a spacecraft, contaminant buildup can still become a problem. Buildup is particularly troublesome during the stages between the final closure of a spacecraft during ground processing and the time that a crewmember enters for the first time during the mission. Typically, the elapsed time between preflight closure and first entry on orbit for spacecraft such as Spacelab modules was 30 days. During that time, the active contamination control systems are not activated and contaminants can potentially build up to levels which exceed the spacecraft maximum allowable concentrations (SMACs) specified by NASA toxicology experts. To prevent excessively high contamination levels at crew entry, the Spacelab active contamination control system was operated for 53 hours just before launch.

  13. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  14. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  15. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  16. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  17. Application of ATC/DDD methodology to evaluate perioperative antimicrobial prophylaxis.

    PubMed

    Akalin, Serife; Kutlu, Selda Sayin; Cirak, Bayram; Eskiçorapcı, Saadettin Yilmaz; Bagdatli, Dilek; Akkaya, Semih

    2012-02-01

    To evaluate quality of perioperative antibiotic prophylaxis (PAP) and to calculate the cost per procedure in a Turkish university hospital. A 352-bed teaching hospital in Denizli, Turkey. An prospective audit was performed between July and October 2010. All clean, clean-contaminated and contaminated elective surgical procedures in ten surgical wards were recorded. Antimicrobial use was calculated per procedure using the ATC-DDD system. The appropriateness of antibiotic use for each procedure was evaluated according to international guidelines on PAP. In addition, the cost per procedure was calculated. Overall, in 577 of the 625 (92.3%) of the studied procedures, PAP was used. PAP was indicated in 12.5% of the group where it was not used, and not indicated in 7.1% of the group where it was used. Unnecessarily prolonged antimicrobial prophylaxis was observed in 56.9% of the procedures, mean duration was 2.6 ± 2.7 days. The most frequently used antimicrobials were cefazolin (117.9 DDD/100-operation) and sulbactam/ampicillin (102.2 DDD/100-operation). The timing of the starting dose was appropriate in 545 procedures (94.5%). In the group that received PAP, only 80 (13.7%) of the procedures were found to be fully appropriate and correct. The density of antimicrobial use per operation was 2.8 DDD. The mean cost of the use of prophylactic antimicrobials 18.6 per procedure. The density of antimicrobial use in PAP was found to be very high in our hospital. Antibiotic overuse extended into the postoperative period.

  18. Influence of blood contamination during multimode adhesive application on the microtensile bond strength to dentin.

    PubMed

    Kucukyilmaz, E; Celik, E U; Akcay, M; Yasa, B

    2017-12-01

    The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (μTBS) of multimode adhesives to dentin when using the self-etch approach. Seventy-five molars were randomly assigned to three adhesive groups comprising 25 specimens each: two multimode adhesives [Single Bond Universal (SBU) and All-Bond Universal (ABU)] and a conventional one-step self-etch adhesive [Clearfil S3 Bond Plus (CSBP)]. Each group was subdivided as follows: (1) uncontaminated (control): bonding application/light curing as a positive control; (2) contamination-1 (cont-1): bonding application/light curing/blood contamination/dry as a negative control; (3) contamination-2 (cont-2): bonding application/light curing/blood contamination/rinse/dry; (4) contamination-3 (cont-3): bonding application/blood contamination/dry/bonding re-application/light curing; and (5) contamination-4 (cont-4): bonding application/blood contamination/rinse/dry/bonding re-application/light curing. Dentin specimens were prepared for μTBS testing after the composite resin application. Data were analyzed with two-way ANOVA and post-hoc tests (α = 0.05). μTBS values were similar in cont-3 groups, and ABU/cont-4 and corresponding control groups, but were significantly lower in the other groups than in their control groups (P < 0.05). Cont-1 groups showed the lowest μTBS values (P < 0.05). Neither decontamination method prevented the decrease in μTBS when contamination occurred after light curing. Drying the blood contaminants and reapplying the adhesive may regain the dentin adhesion when contamination occurs before light curing. Alternatively, rinsing and drying contaminants followed by adhesive re-application may be effective depending on adhesive type.

  19. Cleanroom Garment Silicone Contamination

    NASA Technical Reports Server (NTRS)

    Geer, Wayne; Lepage, Colette

    2006-01-01

    The slide presentation reviews actions taken at Goddard Space Flight Center (GSFC) to eliminate contamination by silicone in clean rooms. Background information includes facilities and hardware affected by silicon contamination, a discussion of the negative aspects of silicone contamination, clean room garments, and how the problem was identified at GSFC. Actions taken by the GSFC Contamination Engineering Group and lessons learned are detailed. Results include: awareness of the silicone issue in laundry, increase in infrastructure and support of the testing lab, establishment of protocols for garment verification, closer relationship established with laundry and converter, specifications for laundry services and garments were strengthened, all consumables are tested before use in clean rooms, and established procedures were used to identify and treat silicone found on face masks.

  20. TREATMENT OF CONTAMINATED SOIL WITH PHOSPHORUS AND MANGANESE OXIDE REDUCES LEAD ADSORPTION BY SPRAGUE-DAWLEY RATS

    EPA Science Inventory

    A study was conducted to determine the extent of adsorption of Pb into young rats that were fed Pb contaminated soil treated with two different sources of P and P plus Mn oxide. Attempts were also made to compare an in vitro, physiologically based extraction procedure test (PBET)...

  1. STUDY TO DETERMINE THE FEASIBILITY OF USING A GROUND-PENETRATING RADAR FOR MORE EFFECTIVE REMEDIATION OF SUBSURFACE CONTAMINATION

    EPA Science Inventory

    Remediation of hazardous material spills is often costly and entails cumbersome procedures. he traditional method is to drill core samples in the area where the contaminant is thought to be present and then analyze these samples in a laboratory. he denser the sampling grid, the m...

  2. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Emergency water supplies due to contaminated water source. 203.61 Section 203.61 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE EMERGENCY EMPLOYMENT OF ARMY AND OTHER RESOURCES, NATURAL DISASTER PROCEDURES Emergency Water Supplies:...

  3. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Emergency water supplies due to contaminated water source. 203.61 Section 203.61 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE EMERGENCY EMPLOYMENT OF ARMY AND OTHER RESOURCES, NATURAL DISASTER PROCEDURES Emergency Water Supplies:...

  4. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Emergency water supplies due to contaminated water source. 203.61 Section 203.61 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE EMERGENCY EMPLOYMENT OF ARMY AND OTHER RESOURCES, NATURAL DISASTER PROCEDURES Emergency Water Supplies:...

  5. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Emergency water supplies due to contaminated water source. 203.61 Section 203.61 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE EMERGENCY EMPLOYMENT OF ARMY AND OTHER RESOURCES, NATURAL DISASTER PROCEDURES Emergency Water Supplies:...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kahraman, A. G.; Kaynak, G.; Akkaya, G.

    Mosses are one of the most widely used procedures to determine via plant of radioactive contamination. The high concentrating capacity of mosses may be used as bioindicator of environmental radioactive contamination. In this study, the mosses were collected in region of Katirli Mountain in northwestern Turkey, activities were determined using TENNELEC LB 1000-PW detector. Samples of mosses growing on soil, rock, and tree bark were collected.

  7. Skylab experiment performance evaluation manual. Appendix S: Experiment T027 contamination measurement sample array (MSFC)

    NASA Technical Reports Server (NTRS)

    Tonetti, B. B.

    1973-01-01

    Analyses for Experiment T027, Contamination Measurement Sample Array (MSFC), to be used for evaluating the performance of the Skylab corrollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.

  8. [Decontamination of dental unit waterlines using disinfectants and filters].

    PubMed

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  9. Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Allton, J. H.; Allen, C. C.; Burkett, P. J.

    2013-01-01

    Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

  10. Process Upsets Involving Trace Contaminant Control Systems

    NASA Technical Reports Server (NTRS)

    Graf, John C.; Perry, Jay; Wright, John; Bahr, Jim

    2000-01-01

    Paradoxically, trace contaminant control systems that suffer unexpected upsets and malfunctions can release hazardous gaseous contaminants into a spacecraft cabin atmosphere causing potentially serious toxicological problems. Trace contaminant control systems designed for spaceflight typically employ a combination of adsorption beds and catalytic oxidation reactors to remove organic and inorganic trace contaminants from the cabin atmosphere. Interestingly, the same design features and attributes which make these systems so effective for purifying a spacecraft's atmosphere can also make them susceptible to system upsets. Cabin conditions can be contributing causes of phenomena such as adsorbent "rollover" and catalyst poisoning can alter a systems performance and in some in stances release contamination into the cabin. Evidence of these phenomena has been observed both in flight and during ground-based tests. The following discussion describes specific instances of system upsets found in trace contaminant control systems, groups these specific upsets into general hazard classifications, and recommends ways to minimize these hazards.

  11. 10 CFR 835.1102 - Control of areas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Radioactive Contamination Control § 835.1102 Control... transfer of removable contamination to locations outside of radiological areas under normal operating conditions. (b) Any area in which contamination levels exceed the values specified in appendix D of this part...

  12. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  13. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  14. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  15. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  16. Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Jennings, Mallory A.; Paul, Heather L.; Waguespack, Glenn M.

    2010-01-01

    This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

  17. A Design Basis for Spacecraft Cabin Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.

    2009-01-01

    Successful trace chemical contamination control is one of the components necessary for achieving good cabin atmospheric quality. While employing seemingly simple process technologies, sizing the active contamination control equipment must employ a reliable design basis for the trace chemical load in the cabin atmosphere. A simplified design basis that draws on experience gained from the International Space Station program is presented. The trace chemical contamination control design load refines generation source magnitudes and includes key chemical functional groups representing both engineering and toxicology challenges.

  18. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air using Multisorbent Samplers

    EPA Pesticide Factsheets

    The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  19. Rapid Assessment of Contaminants and Interferences in Mass Spectrometry Data Using Skyline

    NASA Astrophysics Data System (ADS)

    Rardin, Matthew J.

    2018-04-01

    Proper sample preparation in proteomic workflows is essential to the success of modern mass spectrometry experiments. Complex workflows often require reagents which are incompatible with MS analysis (e.g., detergents) necessitating a variety of sample cleanup procedures. Efforts to understand and mitigate sample contamination are a continual source of disruption with respect to both time and resources. To improve the ability to rapidly assess sample contamination from a diverse array of sources, I developed a molecular library in Skyline for rapid extraction of contaminant precursor signals using MS1 filtering. This contaminant template library is easily managed and can be modified for a diverse array of mass spectrometry sample preparation workflows. Utilization of this template allows rapid assessment of sample integrity and indicates potential sources of contamination. [Figure not available: see fulltext.

  20. Pavlovian disgust conditioning as a model for contamination-based OCD: Evidence from an analogue study

    PubMed Central

    Armstrong, Thomas; Olatunji, Bunmi O.

    2017-01-01

    Pavlovian fear conditioning provides a model for anxiety-related disorders, including obsessive-compulsive disorder (OCD). However, disgust is the predominant emotional response to contamination, which is a common theme in OCD. The present study sought to identify disgust conditioning abnormalities that may underlie excessive contamination concerns relevant to OCD. Individuals high and low in contamination concern (HCC, n = 32; LCC, n = 30) completed an associative learning task in which one neutral face (conditioned stimulus; CS+) was followed by a disgusting image (unconditioned stimulus; US) and another neutral face (CS−) was unreinforced. Following this acquisition procedure, there was an extinction procedure in which both CSs were presented unreinforced. The groups did not show significant differences in discriminant responding to the CSs following acquisition. However, following extinction, the HCC group reported less reduction in their expectancy of the US following the CS+, and also reported greater disgust to the CS+, compared to the LCC group. Increased disgust to the CS+ following both acquisition and extinction was correlated with increased symptoms of contamination-based OCD and increased disgust sensitivity. Additionally, disgust sensitivity mediated group differences in disgust responding to the CS+ at acquisition and extinction. Also, failure to adjust US expectancy in response to extinction partially mediated group differences in disgust to the CS+ following extinction. Together, these findings suggest that excessive contamination concerns observed in OCD may be related to difficulty inhibiting acquired disgust, possibly due to elevated disgust sensitivity that characterizes the disorder. PMID:28391115

  1. Description and hydrogeologic evaluation of nine hazardous-waste sites in Kansas, 1984-86

    USGS Publications Warehouse

    Hart, R.J.; Spruill, T.B.

    1988-01-01

    Wastes generated at nine hazardous-waste sites in Kansas were disposed in open pits, 55-gal drums, or large storage tanks. These disposal methods have the potential to contaminate groundwater beneath the sites, the soil on the sites, and nearby surface water bodies. Various activities on the nine sites included production of diborane, transformer oil waste, production of soda ash, use of solvents for the manufacture of farm implements, reclamation of solvents and paints, oil-refinery wastes, meat packaging, and the manufacture and cleaning of tanker-truck tanks. Monitoring wells were installed upgradient and downgradient from the potential contamination source on each site. Strict decontamination procedures were followed to prevent cross contamination between well installations. Air-quality surveys were made on each site before other investigative procedures started. Hydrogeologic investigative techniques, such as terrain geophysical surveys, gamma-ray logs, and laboratory permeameter tests, were used. Groundwater level measurements provide data to determine the direction of flow. Groundwater contamination detected under the sites posed the greatest threat to the environment because of possible migration of contaminants by groundwater flow. Concentrations of volatile organic compounds, polynuclear aromatic hydrocarbons, and trace metals were detected in the groundwater at several of the sites. Many of the same compounds detected in the groundwater also were detected in soil and bed-material samples collected onsite or adjacent to the sites. Several contaminants were detected in background samples of groundwater and soil. (USGS)

  2. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination.

    PubMed

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as a promising tool to track microbial activity during bioremediation even though further research is still needed to completely understand the bio-geochemical processes involved and their impact on electrical signatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination

    NASA Astrophysics Data System (ADS)

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as a promising tool to track microbial activity during bioremediation even though further research is still needed to completely understand the bio-geochemical processes involved and their impact on electrical signatures.

  4. Trace Contaminant Control During the International Space Station's On-Orbit Assembly and Outfitting

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Achieving acceptable cabin air quality must balance competing elements during spacecraft design, assembly, ground processing, and flight operations. Among the elements that contribute to the trace chemical contaminant load and, therefore, the cabin air quality aboard crewed spacecraft are the vehicle configuration, crew size and activities, mission duration and objectives, materials selection, and vehicle manufacturing and preflight ground processing methods. Trace chemical contaminants produced from pervasive sources such as equipment offgassing, human metabolism, and cleaning fluids during preflight ground processing present challenges to maintaining acceptable cabin air quality. To address these challenges, both passive and active contamination control techniques are used during a spacecraft's design, manufacturing, preflight preparation, and operational phases. Passive contamination control methods seek to minimize the equipment offgassing load by selecting materials, manufacturing processes, preflight preparation processes, and in-flight operations that have low chemical offgassing characteristics. Passive methods can be employed across the spacecraft's entire life cycle from conceptual design through flight operations. However, because the passive contamination control techniques cannot fully eliminate the contaminant load, active contamination control equipment must be deployed aboard the spacecraft to purify and revitalize the cabin atmosphere during in-flight operations. Verifying that the passive contamination control techniques have successfully maintained the total trace contaminant load within the active contamination control equipment's capabilities occurs late in the preflight preparation stages. This verification consists of subjecting the spacecraft to an offgassing test to determine the trace contaminant load. This load is then assessed versus the active contamination control equipment's capabilities via trace contaminant control (TCC) engineering analysis. During the International Space Station's (ISS's) on-orbit assembly and outfitting, a series of engineering analyses were conducted to evaluate how effective the passive TCC methods were relative to providing adequate operational margin for the active TCC equipment's capabilities aboard the ISS. These analyses were based on habitable module and cargo vehicle offgassing test results. The offgassing test for a fully assembled module or cargo vehicle is an important preflight spacecraft evaluation method that has been used successfully during all crewed spacecraft programs to provide insight into how effectively the passive contamination control methods limit the equipment offgassing component of the overall trace contaminant generation load. The progression of TCC assessments beginning in 1998 with the ISS's first habitable element launch and continuing through the final pressurized element's arrival in 2010 are presented. Early cargo vehicle flight assessments between 2008 and 2011 are also presented as well as a discussion on predictive methods for assessing cargo via a purely analytical technique. The technical approach for TCC employed during this 13-year period successfully maintained the cabin atmospheric quality within specified parameters during the technically challenging ISS assembly and outfitting stages. The following narrative provides details on the important role of spacecraft offgassing testing, trace contaminant performance requirements, and flight rules for achieving the ultimate result-a cabin environment that enables people to live and work safely in space.

  5. Scanning Electrochemical Microscopy as a Novel Proximity Sensor for Atraumatic Cochlear Implant Insertion

    PubMed Central

    Velmurugan, J.; Mirkin, M. V.; Svirsky, M. A.; Lalwani, A. K.; Llinas, R. R.

    2014-01-01

    A growing number of minimally invasive surgical and diagnostic procedures require the insertion of an optical, mechanical, or electronic device in narrow spaces inside a human body. In such procedures, precise motion control is essential to avoid damage to the patient’s tissues and/or the device itself. A typical example is the insertion of a cochlear implant which should ideally be done with minimum physical contact between the moving device and the cochlear canal walls or the basilar membrane. Because optical monitoring is not possible, alternative techniques for sub millimeter-scale distance control can be very useful for such procedures. The first requirement for distance control is distance sensing. We developed a novel approach to distance sensing based on the principles of scanning electrochemical microscopy (SECM). The SECM signal, i.e., the diffusion current to a microelectrode, is very sensitive to the distance between the probe surface and any electrically insulating object present in its proximity. With several amperometric microprobes fabricated on the surface of an insertable device, one can monitor the distances between different parts of the moving implant and the surrounding tissues. Unlike typical SECM experiments, in which a disk-shaped tip approaches a relatively smooth sample, complex geometries of the mobile device and its surroundings make distance sensing challenging. Additional issues include the possibility of electrode surface contamination in biological fluids and the requirement for a biologically compatible redox mediator. PMID:24845292

  6. Detection of septicemia in chicken livers by spectroscopy,.

    PubMed

    Dey, B P; Chen, Y R; Hsieh, C; Chan, D E

    2003-02-01

    To establish a procedure for differentiating normal chickens from chickens with septicemia/toxemia (septox) by machine inspection under the Hazard Analysis and Critical Control Point-Based Inspection Models Project, spectral measurements of 300 chicken livers, of which half were normal and half were condemned due to septox conditions, were collected and analyzed. Neural network classification of the spectral data after principal component analysis (PCA) indicated that normal and septox livers were correctly differentiated by spectroscopy at a rate of 96%. Analysis of the data established 100% correlation between the spectroscopic identification and the subset of samples, both normal and septox, that were histopathologically diagnosed. In an attempt to establish the microbiological etiology of the diseased livers, isolates from 30 livers indicated that the poultry carcasses were contaminated mostly with coliforms present in the environment, hindering the isolation of pathogenic microorganisms. Therefore, to establish the cause of diseased livers, a strictly aseptic environment and procedure for sample collection is required.

  7. Isolation and characterization of a Ca/sup 2 +/ carrier candidate from calf heart inner mitochondrial membrane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeng, A.Y.

    1979-01-01

    A protein was isolated from calf heart inner mitochondrial membrane with the aid of an electron paramagnetic resonance assay based on the relative binding properties of Ca/sup 2 +/, Mn/sup 2 +/, and Mg/sup 2 +/ to the protein. Partial delipidation of the protein was performed by using either the organic solvent extraction procedure or the silicic acid column chromatography. Control experiments indicated that the Ca/sup 2 +/ transport properties of the isolated protein were not due to the contaminating phospholipids. A complete delipidation procedure was developd by using Sephadex LH-20 column chromatography. Further characterization of the physical and chemicalmore » properties of the delipidated protein showed that delipidated protein becomes more hydrophobic in the presence of Ca/sup 2 +/ and alkaline pH in the organic solvent extraction experiments. Two possible models of calciphorin-mediated Ca/sup 2 +/ transport in mitochondria are proposed. (PCS)« less

  8. Fault detection in heavy duty wheels by advanced vibration processing techniques and lumped parameter modeling

    NASA Astrophysics Data System (ADS)

    Malago`, M.; Mucchi, E.; Dalpiaz, G.

    2016-03-01

    Heavy duty wheels are used in applications such as automatic vehicles and are mainly composed of a polyurethane tread glued to a cast iron hub. In the manufacturing process, the adhesive application between tread and hub is a critical assembly phase, since it is completely made by an operator and a contamination of the bond area may happen. Furthermore, the presence of rust on the hub surface can contribute to worsen the adherence interface, reducing the operating life. In this scenario, a quality control procedure for fault detection to be used at the end of the manufacturing process has been developed. This procedure is based on vibration processing techniques and takes advantages of the results of a lumped parameter model. Indicators based on cyclostationarity can be considered as key parameters to be adopted in a monitoring test station at the end of the production line due to their not deterministic characteristics.

  9. Payload/orbiter contamination control requirement study: Preliminary contamination mission support plan. [a management analysis of project planning of spacecraft sterilization

    NASA Technical Reports Server (NTRS)

    Bareiss, L. E.; Hooper, V. W.; Ress, E. B.

    1976-01-01

    Progress is reported on the mission support plan and those support activities envisioned to be applicable and necessary during premission and postmission phases of the Spacelab program. The purpose, role, and requirements of the contamination control operations for the first two missions of the Spacelab equipped Space Transportation System are discussed. The organization of the contamination control operation and its relationship to and interfaces with other mission support functions is also discussed. Some specific areas of contamination to be investigated are treated. They are: (1) windows and viewports, (2) experiment equipment, (3) thermal control surfaces, (4) the contaminant induced atmosphere (as differentiated from the normal ambient atmosphere at the orbit altitude), and (5) optical navigation instruments.

  10. Results of the Trace Contaminant Control Needs Evaluation and Sizing Study for Space Suit Life Support Development

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.; Jennings, Mallory A.

    2009-01-01

    The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for CSSE pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

  11. Panel summary of recommendations

    NASA Technical Reports Server (NTRS)

    Dunbar, Bonnie J.; Coleman, Martin E.; Mitchell, Kenneth L.

    1990-01-01

    The following Space Station internal contamination topics were addressed: past flight experience (Skylab and Spacelab missions); present flight activities (Spacelabs and Soviet Space Station Mir); future activities (materials science and life science experiments); Space Station capabilities (PPMS, FMS, ECLSS, and U.S. Laboratory overview); manned systems/crew safety; internal contamination detection; contamination control - stowage and handling; and contamination control - waste gas processing. Space Station design assumptions are discussed. Issues and concerns are discussed as they relate to (1) policy and management, (2) subsystem design, (3) experiment design, and (4) internal contamination detection and control. The recommendations generated are summarized.

  12. The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Kayatin, Matthew J.

    2016-01-01

    Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.

  13. Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

    NASA Technical Reports Server (NTRS)

    Kayatin, Matthew J.; Perry, Jay L.

    2017-01-01

    Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

  14. Assessing Metal Mobilization from Industrially Lead ...

    EPA Pesticide Factsheets

    A series of leaching and partitioning tests (Toxicity Characteristic Leaching Procedure (TCLP), Synthetic Precipitation Leaching Procedure (SPLP), Controlled Acidity Leaching Protocol (CALP), Acid Neutralization Capacity (ANC), and sequential extraction) were applied to three different soils to study potential mobility of metals into groundwater. Two of these soils were lead (Pb)-contaminated soils (Hotspot 1 and Hotspot 2) collected from an urban site associated with lead smelting and other industrial operations. The third sample (Stockpile) was soil affected by previous contamination in the area, removed from residential properties, stockpiled, and selected to be used as fill material in the studied site. The TCLP and CALP showed that Pb could be released from both hotspots, but were not released in the acidic rainfall extraction fluid of the SPLP. The sequential extraction showed that Pb in the hotspot soils was associated with the carbonate fraction, while As was associated with the Fe and Mn oxides. The stockpile released traces of Pb or As in the TCLP and CALP, but the ANC only released Pb under acidic conditions and the SPLP did not release Pb or As. Overall, the projected repository with Stockpile would not pose imminent danger to groundwater because, under the expected environmental conditions, Pb and As tend to remain in the solid phase. The objectives of this study were to determine if the stockpiled soil was suitable for the intended fill purpo

  15. M-52 spray booth qualification test

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The procedures, performance, and results obtained from the M-52 spray booth qualification test are documented. The test was conducted at Thiokol Corporation, Space Operations, M-52 Inert Parts Preparation facility. The purpose of this testing sequence was to ensure the spray booth would produce flight qualified hardware. The testing sequence was conducted in two series. The first series was conducted under CTP-0142, Revision 1. The second series was conducted in accordance with CTP-0142, Revision 2. The test sequence started with CTP-0142, Revision 1. The series consisted of the contamination removal test and the performance test. The contamination removal test was used to assess the Teflon level in the spray booth. The performance test consisted of painting and Chemloking a forward dome inside the spray booth per flight procedures. During the performance test, two sets of witness panels (case/insulation and steel/epoxy/steel) were prepared and pull tested. The CTP-0142, Revision 2, series of testing consisted of re-testing the steel/epoxy/steel witness panels. The pull tests analysis indicates the results of the tensile tests were comparable to the systems tunnel witness panel database. The exposed panel set and the control panel set average tensile values were above the 1-basis lower limits established on the systems tunnel witness panel database. It is recommended that the M-52 spray booth be qualified for producing flight hardware.

  16. Chemical speciation and mobilization of copper and zinc in naturally contaminated mine soils with citric and tartaric acids.

    PubMed

    Pérez-Esteban, Javier; Escolástico, Consuelo; Moliner, Ana; Masaguer, Alberto

    2013-01-01

    A one-step extraction procedure and a leaching column experiment were performed to assess the effects of citric and tartaric acids on Cu and Zn mobilization in naturally contaminated mine soils to facilitate assisted phytoextraction. A speciation modeling of the soil solution and the metal fractionation of soils were performed to elucidate the chemical processes that affected metal desorption by organic acids. Different extracting solutions were prepared, all of which contained 0.01 M KNO(3) and different concentrations of organic acids: control without organic acids, 0.5 mM citric, 0.5 mM tartaric, 10 mM citric, 10 mM tartaric, and 5 mM citric +5 mM tartaric. The results of the extraction procedure showed that higher concentrations of organic acids increased metal desorption, and citric acid was more effective at facilitating metal desorption than tartaric acid. Metal desorption was mainly influenced by the decreasing pH and the dissolution of Fe and Mn oxides, not by the formation of soluble metal-organic complexes as was predicted by the speciation modeling. The results of the column study reported that low concentrations of organic acids did not significantly increase metal mobilization and that higher doses were also not able to mobilize Zn. However, 5-10 mM citric acid significantly promoted Cu mobilization (from 1 mg kg(-1) in the control to 42 mg kg(-1) with 10 mM citric acid) and reduced the exchangeable (from 21 to 3 mg kg(-1)) and the Fe and Mn oxides (from 443 to 277 mg kg(-1)) fractions. Citric acid could efficiently facilitate assisted phytoextraction techniques. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Validation and transferability study of a method based on near-infrared hyperspectral imaging for the detection and quantification of ergot bodies in cereals.

    PubMed

    Vermeulen, Ph; Fernández Pierna, J A; van Egmond, H P; Zegers, J; Dardenne, P; Baeten, V

    2013-09-01

    In recent years, near-infrared (NIR) hyperspectral imaging has proved its suitability for quality and safety control in the cereal sector by allowing spectroscopic images to be collected at single-kernel level, which is of great interest to cereal control laboratories. Contaminants in cereals include, inter alia, impurities such as straw, grains from other crops, and insects, as well as undesirable substances such as ergot (sclerotium of Claviceps purpurea). For the cereal sector, the presence of ergot creates a high toxicity risk for animals and humans because of its alkaloid content. A study was undertaken, in which a complete procedure for detecting ergot bodies in cereals was developed, based on their NIR spectral characteristics. These were used to build relevant decision rules based on chemometric tools and on the morphological information obtained from the NIR images. The study sought to transfer this procedure from a pilot online NIR hyperspectral imaging system at laboratory level to a NIR hyperspectral imaging system at industrial level and to validate the latter. All the analyses performed showed that the results obtained using both NIR hyperspectral imaging cameras were quite stable and repeatable. In addition, a correlation higher than 0.94 was obtained between the predicted values obtained by NIR hyperspectral imaging and those supplied by the stereo-microscopic method which is the reference method. The validation of the transferred protocol on blind samples showed that the method could identify and quantify ergot contamination, demonstrating the transferability of the method. These results were obtained on samples with an ergot concentration of 0.02% which is less than the EC limit for cereals (intervention grains) destined for humans fixed at 0.05%.

  18. Door openings in the operating room are associated with increased environmental contamination.

    PubMed

    Perez, Priscilla; Holloway, Julia; Ehrenfeld, Lucy; Cohen, Susan; Cunningham, Linda; Miley, Gerald B; Hollenbeck, Brian L

    2018-05-04

    Door openings in the operating room (OR) have been hypothesized to increase OR environmental contamination. This study measured average colony-forming units (CFU) in the OR as a function of door openings and other potentially important variables. Bacterial settle plates were placed inside and outside of laminar airflow (LAF) by both exit doors, on the instrument table, and on the back instrument table (if applicable) for 48 orthopedic and general surgery procedures. CFU data were paired to Staphylococcus aureus colonization status, door openings, surgery duration, time of day, OR location, number of staff, use of warming devices, temperature, and humidity. The number of door openings in the OR and surgery duration were significantly associated with increased CFU in the OR overall and outside of LAF. However, under LAF conditions, only the number of OR personnel was significantly associated with increased CFU. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Column studies on the evaluation of novel spacer granules for the removal of arsenite and arsenate from contaminated water.

    PubMed

    Gupta, Anjali; Sankararamakrishnan, Nalini

    2010-04-01

    Decontamination of arsenic ions from aqueous media has been investigated using iron chitosan spacer granules (ICS) as an adsorbent. Drying of beads saturated with a spacer sucrose was considered as simple treatment, to prevent the restriction of polymer network and enhance sorption capacity. The novel sorbent was studied in up flow column experiments conducted at different flow rates, pH and bed depth to quantify the treatment performance. It was found that silicate was more inhibitory than phosphate, and the silicate in groundwater controlled the arsenic removal efficiency. The column regeneration studies were carried out for two sorption-desorption cycles using 0.1N NaOH as the eluant. TCLP leaching tests were conducted on the arsenic loaded adsorbent which revealed the containment of arsenic-laden sludge can be managed without adverse environmental impact. The developed procedure was successfully applied for the removal of both As(III) and As(V) from arsenic contaminated drinking water samples. Copyright 2009 Elsevier Ltd. All rights reserved.

  20. [The distribution of microorganisms in household kitchens. II. Evaluation of results and hygienic inferences].

    PubMed

    Borneff, J; Hassinger, R; Wittig, J; Edenharder, R

    1988-03-01

    The very high morbidity rates of Enteritis infectiosa diseases demand improved prophylactic measures. An important indication of the source of these illnesses is the fact that infections in private households are about three times more frequent than in canteens. Indeed, the rise in morbidity is undoubtedly caused by inadequate treatment of raw products, of meal rests and by insufficient heating processes. Furthermore, in household kitchens no efforts are made to interrupt infection chains, and disinfections are considered as superfluous and housewives are content if their kitchens appear to be clean. The aim of our study performed in a normal household kitchen, was to investigate cross-contamination caused by pathogens, introduced into the kitchen from outdoors. A further aim was to establish the main sources of contamination in order to be able to recommend practical disinfection procedures. The main fields of contamination discovered when 55 meals prepared were: a) working surfaces (including boards of wood and plastics) b) kitchen- and cutting-machines. The amount of test organisms (Sarcinae), introduced into the kitchen (unbeknown to the housewives) by experimentally contaminated minced meat was only reduced by common cleaning procedures, in sofar as nearly half of the original contaminations could be demonstrated to be still present. However, when the normal cleanser was replaced by one containing hypochlorite, and with retention of the same working routines, about 90% bacteriologically clean surfaces were determined. In this way it could be demonstrated that infection chains can be interrupted. It is, however, not correct to compare the efficiency of these procedures with the efficiency of disinfection, according to the Federal Infectious Diseases Act (Bundesseuchengesetz). On practical application of these experiences it must be borne in mind that housewives should not be forced to apply medical disinfection procedures: indeed, traditional and practised cleaning methods should be retained, as far as possible. We recommend therefore that manufacturers supply household cleansers with an anti-bacterial additive, after its application in the kitchens working surfaces and machines are bacteriologically clean. Additionally housewives should be appropriately informed about the necessity of these manipulations. We consider minimization of toxicity and a thorough environmental compatibility of formulations to be self-evident.

  1. Flow-through bioassay for measuring bioaccumulation of toxic substances from sediment

    USGS Publications Warehouse

    Mac, Michael J.; Edsall, Carol C.; Hesselberg, Robert J.; Sayers, Richard E.

    1984-01-01

    Over 10 million cubic meters of sediment are dredged annually from Great Lakes waterways. Because much of this material is taken from harbors, connecting channels, and other nearshore areas that often are contaminated with toxic substances, the sediments proposed for dredging need to be evaluated for the presence of bioavailable contaminants and the potential for toxicity to the biota. Sound decisions on the appropriate disposal of the dredged material can be made only after such an evaluation. Presently, no standardized procedure exists for evaluating dredged material in freshwater systems although current criteria for discharge of dredged material into marine water have been developed (USEPA/CE 1977). In the ocean discharge guideline, it is recommended that bioassays be conducted on liquid, solid, and suspended particulate phases of dredged material. because it appears that the solid phase has the greatest potential for environmental damage and because measurement of bioaccumulation must be made to evaluate sediments for disposal (USEPA/CE 1977, Seeyle and Mac 1983), we developed a bioassay for testing the solid phase of dredged material that measures the survival of organisms and, perhaps more important, the bioaccumulation of toxic substances by aquatic organisms from naturally contaminated sediments (Peddicord et al. 1980; Rubinstein et al. 1980, 1983; Seeyle st al. 1982), several have used testing methods that result in unacceptable mortality to control organisms (Bahnick et al. 1981, Prater et al. 1983). Our bioassay is intended to estimate the potential for bioaccumlation of contaminants from sediments that are not acutely toxic to test organisms, but are suspected of containing persistent contaminants. By using test organisms that are not highly susceptible to toxic compounds, the bioaccumulation test allows estimation of the potential food-chain accumulation of contaminants that may occur in local biota from surficial sediments. In practice, bioaccumulation observed in this bioassay by organisms exposed to test sediments (sediments to be dredged) would be compared to bioaccumulation observed from sediments collected from a reference site (e.g. a disposal site or open lake), and also from control sediments (relatively clean sediment). Decisions could then be based on a comparison of results between tests and reference sediments to determine if disposal would cause dehydration to the habitat, and between reference and control sediment to determine if even the reference material is seriously contaminated. Although the test is not intended to be a toxicity test per se, use of test, reference, and control sediments enables interpretation of any mortality of organisms that may occur during the bioassays. High mortality in bioassays with test or reference sediment would indicate acute toxicity of sediments in the project area. However if high mortality occurs in all three sediments, it can be assumed that the organisms were not in a healthy state at the time of testing. We describe the results of 10-day sediment bioassays in which both mortality and bioaccumulation were measured in four aquatic organisms. We exposed two infaunal organisms and two species of fish to test and control sediments in the laboratory.

  2. INNOVATIVE IN-SITU REMEDIATION OF CONTAMINATED SEDIMENTS FOR SIMULTANEOUS CONTROL OF CONTAMINATION AND EROSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knox, A; Michael Paller, M; Danny D. Reible, D

    2007-11-28

    New technologies are needed that neutralize contaminant toxicity and control physical transport mechanisms that mobilize sediment contaminants. The last 12 months of this comprehensive project investigated the use of combinations of sequestering agents to develop in situ active sediment caps that stabilize mixtures of contaminants and act as a barrier to mechanical disturbance under a broad range of environmental conditions. Efforts focused on the selection of effective sequestering agents for use in active caps, the composition of active caps, and the effects of active cap components on contaminant bioavailability and retention. Results from this project showed that phosphate amendments, somemore » organoclays, and the biopolymer, chitosan, were very effective at removing metals from both fresh and salt water. These amendments also exhibited high retention (80% or more) of most metals indicating reduced potential for remobilization to the water column. Experiments on metal speciation and retention in contaminated sediment showed that apatite and organoclay can immobilize a broad range of metals under both reduced and oxidized conditions. These studies were followed by sequential extractions to evaluate the bioavailability and retention of metals in treated sediments. Metal fractions recovered in early extraction steps are more likely to be bioavailable and were termed the Potentially Mobile Fraction (PMF). Less bioavailable fractions collected in later extraction steps were termed the Recalcitrant Factor (RF). Apatite and organoclay reduced the PMF and increased the RF for several elements, especially Pb, Zn, Ni, Cr, and Cd. Empirically determined partitioning coefficients and modeling studies were used to assess the retention of organic contaminants on selected sequestering agents. Organoclays exhibited exceptionally high sorption of polycyclic aromatic hydrocarbons as indicated by a comparison of K{sub d} values among 12 amendments. These results suggested that organoclays have high potential for controlling organic contaminants. Measured partitioning coefficients were used to model the time required for a contaminant to penetrate sediment caps composed of organoclay. The results showed that a thin layer of highly sorptive organoclay can lead to very long migration times, perhaps longer than the expected lifetime of the contaminant in the sediment environment. A one-dimensional numerical model was used to examine the diffusion of metals through several cap material based on measured and assumed material and transport properties. These studies showed that active caps composed of apatite or organoclay have the potential to delay contaminant breakthrough due to diffusion by hundreds of years or more compared with passive caps composed of sand. Advectively dominated column experiments are currently underway to define effective sorption related retardation factors in promising amendments for various hydrophobic organic compounds. Upon completion of these experiments, advection transient models will be used to estimate the time required for the breakthrough of various contaminants in caps composed of different experimental materials. Biopolymer products for inclusion in active caps were evaluated on the basis of resistance to biodegradation, sorption capacity for organic and inorganic contaminants, and potential for erosion control. More than 20 biopolymer products were evaluated resulting in the selection of chitosan/guar gum cross-linked with borax and xanthan/chitosan cross-linked with calcium chloride for inclusion in active caps to produce a barrier that resists mechanical disturbance. A process was developed for coating sand with cross-linked biopolymers to provide a means for delivery to the sediment surface. Properties of biopolymer coated sand such as carbon fraction (indicating biopolymer coverage), porosity, bulk density, and biodegradability have been evaluated, and experiments are currently underway to assess the resistance of biopolymer coated sand to erosion. Although the ability of active cap materials to remediate contaminants has been emphasized in this study, it is also important to ensure that these materials do not have deleterious effects on the environment. Therefore, promising amendments were evaluated for toxicity using 10 day sediment toxicity tests, the standardized Toxicity Characteristic Leaching Procedure (TCLP), and measurement of metal concentrations in aqueous extracts from the amendments. Metal concentrations were below TCLP limits, EPA ambient water quality criteria, and other ecological screening values These results showed that apatite, organoclay, and biopolymer coated sand do not release metals. The sediment toxicity tests indicated that apatite and biopolymer coated sand are unlikely to adversely affect benthic organisms, even when used in high concentrations.« less

  3. ASSESSMENT OF A SEQUENTIAL EXTRACTION PROCEDURE FOR PERTURBED LEAD-CONTAMINATED SAMPLES WITH AND WITHOUT PHOSPHOROUS AMENDMENTS

    EPA Science Inventory

    Sequential extraction procedures are used to determine the solid-phase association in which elements of interest exist in soil and sediment matrices. Foundational work by Tessier et al. (1) has found widespread acceptance and has worked tolerably as an operational definition for...

  4. 9 CFR 354.244 - Temperatures and cooling and freezing procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Temperatures and cooling and freezing procedures. 354.244 Section 354.244 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE... Maintenance of Sanitary Conditions and Precautions Against Contamination of Products § 354.244 Temperatures...

  5. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments: Standard Operating Procedure for PED Deployment

    DTIC Science & Technology

    2012-12-01

    mineral and organic materials situated beneath an aqueous layer. PEDs assembled, installed, and retrieved following these procedures will be suitable...at a minimum, wearing adequate protective equipment, flotation devices, and making use of lifelines. 8.0 References Massachusetts Institute of

  6. US EPA Base Study Standard Operating Procedure for Sampling Volatile Organic Compounds in Indoor Air Using Evacuated Canisters

    EPA Pesticide Factsheets

    The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.

  7. Prevention of EP Migratory Contamination in a Cluster Randomized Trial to Increase tPA Use in Stroke (The INSTINCT Trial)

    PubMed Central

    Weston, Victoria C.; Meurer, William J.; Frederiksen, Shirley M.; Fox, Allison K.; Scott, Phillip A.

    2016-01-01

    Objectives Cluster randomized trials (CRTs) are increasingly utilized to evaluate quality improvement interventions aimed at healthcare providers. In trials testing emergency department interventions, migration of emergency physicians (EPs) between hospitals is an important concern, as contamination may affect both internal and external validity. We hypothesized that geographically isolating emergency departments would prevent migratory contamination in a CRT designed to increase ED delivery of tPA in stroke (The INSTINCT Trial). Methods INSTINCT was a prospective, cluster randomized, controlled trial. 24 Michigan community hospitals were randomly selected in matched pairs for study. Contamination was defined at the cluster level, with substantial contamination defined a priori as >10% of EPs affected. Non-adherence, total crossover (contamination + non-adherence), migration distance and characteristics were determined. Results 307 emergency physicians were identified at all sites. Overall, 7 (2.3%) changed study sites. 1 moved between control sites, leaving 6 (2.0%) total crossovers. Of these, 2 (0.7%) moved from intervention to control (contamination) and 4 (1.3%) moved from control to intervention (non-adherence). Contamination was observed in 2 of 12 control sites, with 17% and 9% contamination of the total site EP workforce at follow-up, respectively. Average migration distance was 42 miles for all EPs moving in the study and 35 miles for EPs moving from intervention to control sites. Conclusion The mobile nature of emergency physicians should be considered in the design of quality improvement CRTs. Increased reporting of contamination in CRTs is encouraged to clarify thresholds and facilitate CRT design. PMID:25440230

  8. Process for testing a xenon gas feed system of a hollow cathode assembly

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J. (Inventor); Verhey, Timothy R. R. (Inventor); Soulas, George C. (Inventor)

    2004-01-01

    The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma, at voltages of less than 20 Volts.

  9. Process for Ignition of Gaseous Electrical Discharge Between Electrodes of a Hollow Cathode Assembly

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J. (Inventor); Verhey, Timothy R. R. (Inventor); Soulas, George C. (Inventor)

    2000-01-01

    The design and manufacturing processes for Hollow Cathode Assemblies (HCA's) that operate over a broad range of emission currents up to 30 Amperes, at low potentials, with lifetimes in excess of 17,500 hours. The processes include contamination control procedures which cover hollow cathode component cleaning procedures, gas feed system designs and specifications, and hollow cathode activation and operating procedures to thereby produce cathode assemblies that have demonstrated stable and repeatable operating conditions, for both the discharge current and voltage. The HCA of this invention provides lifetimes of greater than 10,000 hours, and expected lifetimes of greater than 17,500 hours, whereas the present state-of-the-art is less than 500 hours at emission currents in excess of 1 Ampere. Stable operation is provided over a large range of operating emission currents, up to a 6:1 ratio, and this HCA can emit electron currents of up to 30 Amperes in magnitude to an external anode that simulates the current drawn to a space plasma, at voltages of less than 20 Volts.

  10. Contamination control requirements implementation for the James Webb Space Telescope (JWST), part 2: spacecraft, sunshield, observatory, and launch

    NASA Astrophysics Data System (ADS)

    Wooldridge, Eve M.; Schweiss, Andrea; Henderson-Nelson, Kelly; Woronowicz, Michael; Patel, Jignasha; Macias, Matthew; McGregor, R. Daniel; Farmer, Greg; Schmeitzky, Olivier; Jensen, Peter; Rumler, Peter; Romero, Beatriz; Breton, Jacques

    2014-09-01

    This paper will continue from Part 1 of JWST contamination control implementation. In addition to optics, instruments, and thermal vacuum testing, JWST also requires contamination control for a spacecraft that must be vented carefully in order to maintain solar array and thermal radiator thermal properties; a tennis court-sized sunshield made with 1-2 mil Kapton™ layers that must be manufactured and maintained clean; an observatory that must be integrated, stowed and transported to South America; and a rocket that typically launches commercial payloads without contamination sensitivity. An overview of plans developed to implement contamination control for the JWST spacecraft, sunshield, observatory and launch vehicle will be presented.

  11. Small-Item Vapor Test Method, FY11 Release

    DTIC Science & Technology

    2012-07-01

    to this test procedure is provided alphabetically in the following list: absorption: The uptake of a contaminant INTO the volume of a material. The... powders , wipes), or gas-phase (fumigants, including aerosols). decontamination process: The process of making any person, object, or area safe by...with another contaminant. Generally, bare metals and glass are nonsorptive materials for some agents. operational decontamination: Decontamination

  12. Annotated Bibliography of Bioassays Related to Sediment Toxicity Testing in Washington State

    DTIC Science & Technology

    1990-10-01

    effects of sediments contaminated with heavy metals, petroleum hydrocarbons , synthetic organic compounds and radionuclides. It also provides an... molluscs (adults only), echinoderm larvae and fish), and bioassay procedures with selected toxicants (metals, petrochemicals, pesticides, contaminated...reference sediment + 15 mm test sediment. Bioaccumulation tests (with same organisms) are a’so discussed. EPA/COE (U.S. Environmental Protection Agency

  13. Skin decontamination: principles and perspectives.

    PubMed

    Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I

    2013-11-01

    Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.

  14. Understanding the contamination of food with mineral oil: the need for a confirmatory analytical and procedural approach.

    PubMed

    Spack, Lionel W; Leszczyk, Gabriela; Varela, Jesus; Simian, Hervé; Gude, Thomas; Stadler, Richard H

    2017-06-01

    The contamination of food by mineral oil hydrocarbons (MOHs) found in packaging is a long-running concern. A main source of MOHs in foods is the migration of mineral oil from recycled board into the packed food products. Consequently, the majority of food manufacturers have taken protective measures, e.g., by using virgin board instead of recycled fibres and, where feasible, introducing functional barriers to mitigate migration. Despite these protective measures, MOHs may still be observed in low amounts in certain food products, albeit due to different entry points across the food supply chain. In this study, we successfully apply gas chromatography coupled to mass spectrometry (GC-MS) to demonstrate, through marker compounds and the profile of the hydrocarbon response, the possible source of contamination using mainly chocolate and cereals as food matrices. The conventional liquid chromatography-one-dimensional GC coupled to a flame ionisation detector (LC-GC-FID) is a useful screening method, but in cases of positive samples it must be complemented by a confirmatory method such as, for example, GC-MS, allowing a verification of mineral oil contamination. The procedural approach proposed in this study entails profile analysis, marker identification, and interpretation and final quantification.

  15. A study of blood contamination of Siqveland matrix bands.

    PubMed

    Lowe, A H; Bagg, J; Burke, F J T; MacKenzie, D; McHugh, S

    2002-01-12

    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P < 0.001). If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment.

  16. Effect of fecal contamination and cross-contamination on numbers of coliform, Escherichia coli, Campylobacter, and Salmonella on immersion-chilled broiler carcasses.

    PubMed

    Smith, D P; Cason, J A; Berrang, M E

    2005-07-01

    The effect of prechill fecal contamination on numbers of bacteria on immersion-chilled carcasses was tested in each of three replicate trials. For each trial, 16 eviscerated broiler carcasses were split into 32 halves and assigned to one of two groups. Cecal contents (0.1 g inoculated with Campylobacter and nalidixic acid-resistant Salmonella) were applied to each of eight halves in one group (direct contamination) that were placed into one paddle chiller (contaminated), whereas the other paired halves were placed into another chiller (control). From the second group of eight split birds, one of each paired half was placed in the contaminated chiller (to determine cross-contamination) and the other half was placed in the control chiller. Postchill carcass halves were sampled by a 1-min rinse in sterile water, which was collected and cultured. Bacterial counts were reported as log CFU per milliliter of rinsate. There were no significant statistical differences (paired t test, P < 0.05) from direct contamination for coliforms (mean 3.0 log CFU) and Escherichia coli (mean 2.7 log CFU), although Campylobacter numbers significantly increased from control values because of direct contamination (1.5 versus 2.1 log CFU), and the incidence increased from 79 to 100%. There was no significant effect of cross-contamination on coliform (mean 2.9 log CFU) or E. coli (mean 2.6 log CFU) numbers. Nevertheless, Campylobacter levels were significantly higher after exposure to cross-contamination (1.6 versus 2.0 log CFU), and the incidence of this bacterium increased from 75 to 100%. Salmonella-positive halves increased from 0 to 42% postchill because of direct contamination and from 0 to 25% as a result of cross-contamination after chilling. Water samples and surface swabs taken postchill from the contaminated chiller were higher for Campylobacter than those taken from the control chiller. Immersion chilling equilibrated bacterial numbers between contaminated and control halves subjected to either direct contamination or cross-contamination for coliforms and E. coli. Campylobacter numbers, Campylobacter incidence, and Salmonella incidence increased because of both direct contamination and cross-contamination in the chiller. Postchill E. coli numbers did not indicate which carcass halves were contaminated with feces before chilling.

  17. External Contamination Control of Attached Payloads on the International Space Station

    NASA Technical Reports Server (NTRS)

    Soares, Carlos E.; Mikatarian, Ronald R.; Olsen, Randy L.; Huang, Alvin Y.; Steagall, Courtney A.; Schmidl, William D.; Wright, Bruce D.; Koontz, Steven

    2012-01-01

    The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.

  18. Laboratory Evaluation of Light Obscuration Particle Counters used to Establish use Limits for Aviation Fuel

    DTIC Science & Technology

    2015-12-01

    markings are indicated, follow agency authorization procedures , e.g. RD/FRD, PROPIN, ITAR, etc. Include copyright information. 13. SUPPLEMENTARY...Contamination in Distillate Fuels (Visual Inspection Procedures ), as a final check of fuel to ensure aviation fuel is clear and bright before flight...Laboratories at the Detroit Arsenal. The online procedure for evaluating the light obscuration particle counters was modified from the concepts found

  19. Prospective randomized assessment of single versus double-gloving for general surgical procedures.

    PubMed

    Na'aya, H U; Madziga, A G; Eni, U E

    2009-01-01

    There is increased tendency towards double-gloving by general surgeons in our practice, due probably to awareness of the risk of contamination with blood or other body fluids during surgery. The aim of the study was to compare the relative frequency of glove puncture in single-glove versus double glove sets in general surgical procedures, and to determine if duration of surgery affects perforation rate. Surgeons at random do single or double gloves at their discretion, for general surgical procedures. All the gloves used by the surgeons were assessed immediately after surgery for perforation. A total of 1120 gloves were tested, of which 880 were double-glove sets and 240 single-glove sets. There was no significant difference in the overall perforation rate between single and double glove sets (18.3% versus 20%). However, only 2.3% had perforations in both the outer and inner gloves in the double glove group. Therefore, there was significantly greater risk for blood-skin exposure in the single glove sets (p < 0.01). The perforation rate was also significantly greater during procedures lasting an hour or more compared to those lasting less than an hour (p < 0.01). Double-gloving reduces the risk of blood-skin contamination in all general surgical procedures, and especially so in procedures lasting an hour or more.

  20. Clean room survey and assessment, volume 5, appendix H

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The scope of this task is to perform a comparative analysis of the various Environmental Control Life Support System (ECLSS) options for different growth scenarios. The Space Station Freedom ECLSS design and existing ground-based clean room facilities are used as a baseline for comparison. Specifically addressed here are the ground based clean room facilities at the Marshall Space Flight Center (MSFC). Given here is an evaluation of the facilities, equipment, technologies, and procedures used to maintain specified environments in typical aerospace industrial areas. Twenty-five specific clean rooms are evaluated. The objectives were to collect, compare, and catalog data for each specified facility in the areas of engineering and design, construction materials, work stations, contamination control, particulate elimination, entry systems, and instrumentation, and to make recommendations concerning enhancements required to assure an efficient and orderly evolution of MSFC clean room environmental control facilities.

  1. Assessment of metal and PAH profiles in SUDS soil based on an improved experimental procedure.

    PubMed

    Tedoldi, Damien; Chebbo, Ghassan; Pierlot, Daniel; Kovacs, Yves; Gromaire, Marie-Christine

    2017-11-01

    The increasing use of infiltration-based systems for stormwater management questions the soil's ability to act as a long-term filter for runoff contaminants, and brings about operational matters regarding the most effective maintenance practices to enhance contaminant retention in SUDS. This paper reports the vertical extent of metal and PAH contamination in the soil of seven source-control devices in operation for more than 10 years, assessed via a two-step sampling strategy to optimize the representativeness of the contamination profiles. Metal distribution was typically characterized by a significant surface buildup, followed by a decrease in concentrations with increasing depth, usually coming close to the background values. PAH were more heterogeneously distributed with depth, but their accumulation was globally restricted to the upper 10-40 cm. This indicates an interesting potential for pollution interception by the upper horizons of soil, but does not necessarily prevent from downward fluxes, even while measuring low surface contents, as deeper strata may have lesser retention capacities. Specific amendments of the surface soil may help prevent this problem. Surface soil renewal - which would be necessary over 2.5-30 cm in four sites, according to the "strictest" standards for soil remediation - may regenerate the soil's sorption potential, but such a practice could disrupt the interactions with the local ecosystem, so this should be carried out exceptionally and not as a preventive measure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Safety of refrigerated storage of admixed parenteral fluids.

    PubMed Central

    Weil, D C; Arnow, P M

    1988-01-01

    Many hospital pharmacies are reluctant to store admixed parenteral fluids longer than 24 to 48 h because of concern about possible microbial contamination. We evaluated the safety of prolonged refrigerated storage of admixtures by culturing mixtures in 471 bags prepared routinely in a hospital pharmacy and stored at 4 degrees C for up to 15 days. Low-level contamination (1 CFU per bag) was found in 3 of 253 solutions of saline and/or glucose into which nonantibiotic additives had been injected. None of 171 saline and/or glucose solutions with antibiotic additives or 47 parenteral nutrition fluids was culture positive. The risk of contamination did not increase with duration of storage, and none of 107 bags stored greater than or equal to 5 days was culture positive. Laboratory studies to measure growth of bacteria and fungi in glucose infusate and parenteral nutrition solutions confirmed that storage at 4 degrees C suppresses growth. Eight of twelve bacterial isolates grew in glucose solutions at 25 degrees C, while none grew at 4 degrees C. Of 13 species of bacteria and fungi inoculated in parenteral nutrition fluids, 8 proliferated at 25 degrees C and none proliferated at 4 degrees C. We conclude that refrigerated storage of parenteral fluids for up to 1 week following admixture, as permitted by Centers for Disease Control guidelines, does not appear to increase the risk of microbial contamination when standard aseptic procedures for admixing and storage are followed. PMID:3183025

  3. Quantification issues of trace metal contaminants on silicon wafers by means of TOF-SIMS, ICP-MS, and TXRF

    NASA Astrophysics Data System (ADS)

    Rostam-Khani, P.; Hopstaken, M. J. P.; Vullings, P.; Noij, G.; O'Halloran, O.; Claassen, W.

    2004-06-01

    Measurement of surface metal contamination on silicon wafers is essential for yield enhancement in IC manufacturing. Vapor phase decomposition coupled with either inductively coupled plasma mass spectrometry (VPD-ICP-MS), or total reflection X-ray fluorescence (VPD-TXRF), TXRF and more recently time of flight secondary ion mass spectrometry (TOF-SIMS) are used to monitor surface metal contamination. These techniques complement each other in their respective strengths and weaknesses. For reliable and accurate quantification, so-called relative sensitivity factors (RSF) are required for TOF-SIMS analysis. For quantification purposes in VPD, the collection efficiency (CE) is important to ensure complete collection of contamination. A standard procedure has been developed that combines the determination of these RSFs as well as the collection efficiency using all the analytical techniques mentioned above. Therefore, sample wafers were intentionally contaminated and analyzed (by TOF-SIMS) directly after preparation. After VPD-ICP-MS, several scanned surfaces were analyzed again by TOF-SIMS. Comparing the intensities of the specific metals before and after the VPD-DC procedure on the scanned surface allows the determination of so-called removing efficiency (RE). In general, very good agreement was obtained comparing the four analytical techniques after updating the RSFs for TOF-SIMS. Progress has been achieved concerning the CE evaluation as well as determining the RSFs more precisely for TOF-SIMS.

  4. Effect of mobile laminar airflow units on airborne bacterial contamination during neurosurgical procedures.

    PubMed

    von Vogelsang, A-C; Förander, P; Arvidsson, M; Löwenhielm, P

    2018-03-24

    Surgical site infections (SSIs) after neurosurgery are potentially life-threatening and entail great costs. SSIs may occur from airborne bacteria in the operating room, and ultraclean air is desired during infection-prone cleaning procedures. Door openings and the number of persons present in the operating room affect the air quality. Mobile laminar airflow (MLAF) units, with horizontal laminar airflow, have previously been shown to reduce airborne bacterial contamination. To assess the effect of MLAF units on airborne bacterial contamination during neurosurgical procedures. In a quasi-experimental design, bacteria-carrying particles (colony-forming units: cfu) during neurosurgical procedures were measured with active air-sampling in operating rooms with conventional turbulent ventilation, and with additional MLAF units. The MLAF units were shifted between operating rooms monthly. Colony-forming unit count and bacterial species detection were conducted after incubation. Data was collected for a period of 18 months. A total of 233 samples were collected during 45 neurosurgical procedures. The use of MLAF units significantly reduced the numbers of cfu in the surgical site area (P < 0.001) and above the instrument table (P < 0.001). Logistic regression showed that the only significant predictor affecting cfu count was the use of MLAF units (odds ratio: 41.6; 95% confidence interval: 11.3-152.8; P < 0.001). The most frequently detected bacteria were coagulase-negative staphylococci. MLAF successfully reduces cfu during neurosurgery to ultraclean air levels. MLAF units are valuable when the main operating room ventilation system is unable to produce ultraclean air in infection-prone clean neurosurgery. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. Quantitative real-time PCR technique for the identification of E. coli residual DNA in streptokinase recombinant product.

    PubMed

    Fazelahi, Mansoureh; Kia, Vahid; Kaghazian, Hooman; Paryan, Mahdi

    2017-11-26

    Recombinant streptokinase is a biopharmaceutical which is usually produced in E. coli. Residual DNA as a contamination and risk factor may remain in the product. It is necessary to control the production procedure to exclude any possible contamination. The aim of the present study was to develop a highly specific and sensitive quantitative real-time PCR-based method to determine the amount of E. coli DNA in recombinant streptokinase. A specific primers and a probe was designed to detect all strains of E. coli. To determine the specificity, in addition to using NCBI BLASTn, 28 samples including human, bacterial, and viral genomes were used. The results confirmed that the assay detects no genomic DNA but E. coli's and the specificity was determined to be 100%. To determine the sensitivity and limit of detection of the assay, a 10-fold serial dilution (10 1 to 10 7 copies/µL) was tested in triplicate. The sensitivity of the test was determined to be 101 copies/µL or 35 fg/µL. Inter-assay and intra-assay were determined to be 0.86 and 1.69%, respectively. Based on the results, this assay can be used as an accurate method to evaluate the contamination of recombinant streptokinase in E. coli.

  6. Occupational exposure of electrical utility linemen to pentachlorophenol.

    PubMed

    Thind, K S; Karmali, S; House, R A

    1991-12-01

    Occupational exposure to pentachlorophenol (PCP) for a crew of electrical utility linemen was monitored over a 6-month period by using total PCP in urine per gram of creatinine as a biological monitoring parameter. Urine samples were collected from three groups: A, B, and control, at a 4-week frequency during 1989. Group A was required to use new gloves after each 4-week work period; Group B changed gloves on a need basis as per normal operating procedure. The control group consisted of members of the administrative office staff who were not occupationally exposed. The used gloves returned by Group A were monitored for contamination. On the basis of analysis of the collected data the following conclusions were noted. (1) The linemen experienced a seasonal exposure pattern with exposures peaking in July and August. This seasonal effect was also observed with glove contamination data. (2) The glove contamination levels were significantly associated with urine PCP concentrations when both these variables were expressed as geometric means for the individuals in Group A. Inclusion of work experience as an additional variable enhances this association. Less experienced linemen tended to perform more activities with higher current exposure and had higher urine and glove PCP measurements and higher correlations between these variables than more experienced linemen. (3) Over the study period, the difference in long-term exposures of Group A and Group B linemen was not statistically significant. (4) The long-term individual exposures, calculated as the geometric mean of each individual's sequential sample readings, were all below the biological monitoring guideline value of 1000 micrograms PCP/g creatinine.

  7. Evaluation of Using Caged Clams to Monitor Contaminated Groundwater Exposure in the Near-Shore Environment of the Hanford Site 300 Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larson, Kyle B.; Poston, Ted M.; Tiller, Brett L.

    2008-01-31

    The Asiatic clam (Corbicula fluminea) has been identified as an indicator species for locating and monitoring contaminated groundwater in the Columbia River. Pacific Northwest National Laboratory conducted a field study to explore the use of caged Asiatic clams to monitor contaminated groundwater upwelling in the 300 Area near-shore environment and assess seasonal differences in uranium uptake in relation to seasonal flow regimes of the Columbia River. Additional objectives included examining the potential effects of uranium accumulation on growth, survival, and tissue condition of the clams. This report documents the field conditions and procedures, laboratory procedures, and statistical analyses used inmore » collecting samples and processing the data. Detailed results are presented and illustrated, followed by a discussion comparing uranium concentrations in Asiatic clams collected at the 300 Area and describing the relationship between river discharge, groundwater indicators, and uranium in clams. Growth and survival, histology, and other sources of environmental variation also are discussed.« less

  8. Bonded-phase extraction column isolation of organic compounds in groundwater at a hazardous waste site

    USGS Publications Warehouse

    Rostad, C.E.; Pereira, W.E.; Ratcliff, S.M.

    1984-01-01

    A procedure for isolation of hazardous organic compounds from water for gas chromatography/mass spectrometry analysis Is presented and applied to creosote- and pentachlorophenol-contaminated groundwater resulting from wood-treatment processes. This simple procedure involved passing a 50-100-mL sample through a bonded-phase extraction column, eluting the trapped organic compounds from the column with 2-4 mL of solvent, and evaporating the sample to 100 ??L with a stream of dry nitrogen, after which the sample was ready for gas chromatography/mass spectrometry analysis. Representative compounds indicative of creosote contamination were used for recovery and precision studies from the cyclohexyl-bonded phase. Recovery of these compounds from n-octyl-, n-octadecyl-, cyclohexyl-, and phenyl-bonded phases was compared. The bonded phase that exhibited the best recovery and least bias toward acidic or basic cmpounds was the n-octadecyl phase. Detailed compound Identification Is given for compounds Isolated from creosote- and pentachlorophenol-contaminated groundwater using the cyclohexyl-bonded phase.

  9. Radiographic contrast media conservation systems.

    PubMed

    1996-11-01

    During procedures (such as cardiac catheterizations) that use contrast media, or dyes, large amounts of unused dye can become contaminated with the patient's blood and must be thrown out. Radiographic contrast media conservation systems (RCMCSs) are administration sets designed to reduce the waste of these expensive dyes by (1) isolating the bags or bottles supplying the dyes from contamination, allowing the remaining contents to be used again on another patient, and (2) minimizing the amount of dye left in the administration set (and therefore discarded) at the end of the procedure. In this Evaluation, we examined five burette RCMCSs from three suppliers. We tested the systems for their ability to protect the source containers from contamination, for their performance and design features, and for their ease of use. We also provide information on transfer line assembly RCMCSs, which perform some of the same functions but without using a burette, in a supplementary article within this Evaluation. In addition, a brief Purchasing Guide provides recommendations on deciding whether to purchase RCMCSs and how to choose among systems.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    This report focuses on the detection and control of radioactive contamination, which are an integral part of an aggressive ALARA program and provide an indication of the effectiveness of engineering controls and proper work practices in preventing the release of radioactive material. Radioactive contamination, if undetected or not properly controlled, can be spread and contaminate areas, equipment, personnel, and the environment.

  11. Prevention of emergency physician migratory contamination in a cluster randomized trial to increase tissue plasminogen activator use in stroke (the INSTINCT trial).

    PubMed

    Weston, Victoria C; Meurer, William J; Frederiksen, Shirley M; Fox, Allison K; Scott, Phillip A

    2014-12-01

    Cluster randomized trials (CRTs) are increasingly used to evaluate quality improvement interventions aimed at health care providers. In trials testing emergency department (ED) interventions, migration of emergency physicians (EPs) between hospitals is an important concern, as contamination may affect both internal and external validity. We hypothesized that geographically isolating EDs would prevent migratory contamination in a CRT designed to increase ED delivery of tissue plasminogen activator (tPA) in stroke (the INSTINCT trial). INSTINCT was a prospective, cluster randomized, controlled trial. Twenty-four Michigan community hospitals were randomly selected in matched pairs for study. Contamination was defined at the cluster level, with substantial contamination defined a priori as greater than 10% of EPs affected. Nonadherence, total crossover (contamination+nonadherence), migration distance, and characteristics were determined. Three hundred seven EPs were identified at all sites. Overall, 7 (2.3%) changed study sites. One moved between control sites, leaving 6 (2.0%) total crossovers. Of these, 2 (0.7%) moved from intervention to control (contamination); and 4 (1.3%) moved from control to intervention (nonadherence). Contamination was observed in 2 of 12 control sites, with 17% and 9% contamination of the total site EP workforce at follow-up, respectively. Average migration distance was 42 miles for all EPs moving in the study and 35 miles for EPs moving from intervention to control sites. The mobile nature of EPs should be considered in the design of quality improvement CRTs. Increased reporting of contamination in CRTs is encouraged to clarify thresholds and facilitate CRT design. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Rapid virus detection procedure for molecular tracing of shellfish associated with disease outbreaks.

    PubMed

    de Roda Husman, Ana Maria; Lodder-Verschoor, Froukje; van den Berg, Harold H J L; Le Guyader, Françoise S; van Pelt, Hilde; van der Poel, Wim H M; Rutjes, Saskia A

    2007-04-01

    Detection of pathogenic viruses in oysters implicated in gastroenteritis outbreaks is often hampered by time-consuming, specialist virus extraction methods. Five virus RNA extraction methods were evaluated with respect to performance characteristics and sensitivity on artificially contaminated oyster digestive glands. The two most promising procedures were further evaluated on bioaccumulated and naturally contaminated oysters. The most efficient method was used to trace the source in an outbreak situation. Out of five RNA extraction protocols, PEG precipitation and the RNeasy Kit performed best with norovirus genogroup III-spiked digestive glands. Analyzing 24-h bioaccumulated oysters revealed a slightly better sensitivity with PEG precipitation, but the RNeasy Kit was less prone to concentrate inhibitors. The latter procedure demonstrated the presence of human noroviruses in naturally contaminated oysters and oysters implicated in an outbreak. In this outbreak, in four out of nine individually analyzed digestive glands, norovirus was detected. In one of the oysters and in one of the fecal samples of the clinical cases, identical norovirus strains were detected. A standard and rapid virus extraction method using the RNeasy Kit appeared to be most useful in tracing shellfish as the source in gastroenteritis outbreaks, and to be able to make effective and timely risk management decisions.

  13. Guidelines for collecting and processing samples of stream bed sediment for analysis of trace elements and organic contaminants for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.; Capel, Paul D.

    1994-01-01

    A major component of the U.S. Geological Survey's National Water-Quality Assessment program is to assess the occurrence and distribution of trace elements and organic contaminants in streams. The first phase of the strategy for the assessment is to analyze samples of bed sediments from depositional zones. Fine-grained particles deposited in these zones are natural accumulators of trace elements and hydrophobic organic compounds. For the information to be comparable among studies in many different parts of the Nation, strategies for selecting stream sites and depositional zones are critical. Fine-grained surficial sediments are obtained from several depositional zones within a stream reach and composited to yield a sample representing average conditions. Sample collection and processing must be done consistently and by procedures specifically designed to separate the fine material into fractions that yield uncontaminated samples for trace-level analytes in the laboratory. Special coring samplers and other instruments made of Teflon are used for collection. Samples are processed through a 2.0-millimeter stainless-steel mesh sieve for organic contaminate analysis and a 63-micrometer nylon-cloth sieve for trace-element analysis. Quality assurance is maintained by strict collection and processing procedures, duplicate samplings, and a rigid cleaning procedure.

  14. Assessment of molecular contamination in mask pod

    NASA Astrophysics Data System (ADS)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic contaminants: by inline techniques based on Adixen humidity, also VOC and organic sensors, together by off-line techniques already used in the extensive previous mask pods benchmark (TD-GCMS & Ionic Chromatography). Humidity and VOC levels from mask carriers had shown significant reduction after Adixen pod conditioning process. Focus had been made on optimized vacuum step (for AMC) after particles carrier cleaning cycle. Based upon these key results new procedures, as well as guidelines for mask carrier cleaning optimization are proposed to improve pod contamination control. Summary results/next steps: This paper reports molecular contamination measurement campaigns performed by a pool of European partners along the mask supply chain. It allows us to investigate, identify and quantify critical molecular contamination in mask pod, as well as VOC and humidity, issues depending on locations, uses, and carrier's type. Preliminary studies highlight initial process solutions for pods conditioning that are being used for short term industrialization and further industrialized.

  15. Microbiological water methods: quality control measures for Federal Clean Water Act and Safe Drinking Water Act regulatory compliance.

    PubMed

    Root, Patsy; Hunt, Margo; Fjeld, Karla; Kundrat, Laurie

    2014-01-01

    Quality assurance (QA) and quality control (QC) data are required in order to have confidence in the results from analytical tests and the equipment used to produce those results. Some AOAC water methods include specific QA/QC procedures, frequencies, and acceptance criteria, but these are considered to be the minimum controls needed to perform a microbiological method successfully. Some regulatory programs, such as those at Code of Federal Regulations (CFR), Title 40, Part 136.7 for chemistry methods, require additional QA/QC measures beyond those listed in the method, which can also apply to microbiological methods. Essential QA/QC measures include sterility checks, reagent specificity and sensitivity checks, assessment of each analyst's capabilities, analysis of blind check samples, and evaluation of the presence of laboratory contamination and instrument calibration and checks. The details of these procedures, their performance frequency, and expected results are set out in this report as they apply to microbiological methods. The specific regulatory requirements of CFR Title 40 Part 136.7 for the Clean Water Act, the laboratory certification requirements of CFR Title 40 Part 141 for the Safe Drinking Water Act, and the International Organization for Standardization 17025 accreditation requirements under The NELAC Institute are also discussed.

  16. 9 CFR 381.151 - Adulteration of product by polluted water; procedure for handling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Adulteration of product by polluted...; Processing Requirements § 381.151 Adulteration of product by polluted water; procedure for handling. (a) In.... (c) Hermetically sealed containers of poultry product which have been contaminated by polluted water...

  17. Two important limitations relating to the spiking of environmental samples with contaminants of emerging concern: How close to the real analyte concentrations are the reported recovered values?

    PubMed

    Michael, Costas; Bayona, Josep Maria; Lambropoulou, Dimitra; Agüera, Ana; Fatta-Kassinos, Despo

    2017-06-01

    Occurrence and effects of contaminants of emerging concern pose a special challenge to environmental scientists. The investigation of these effects requires reliable, valid, and comparable analytical data. To this effect, two critical aspects are raised herein, concerning the limitations of the produced analytical data. The first relates to the inherent difficulty that exists in the analysis of environmental samples, which is related to the lack of knowledge (information), in many cases, of the form(s) of the contaminant in which is present in the sample. Thus, the produced analytical data can only refer to the amount of the free contaminant ignoring the amount in which it may be present in other forms; e.g., as in chelated and conjugated form. The other important aspect refers to the way with which the spiking procedure is generally performed to determine the recovery of the analytical method. Spiking environmental samples, in particular solid samples, with standard solution followed by immediate extraction, as is the common practice, can lead to an overestimation of the recovery. This is so, because no time is given to the system to establish possible equilibria between the solid matter-inorganic and/or organic-and the contaminant. Therefore, the spiking procedure need to be reconsidered by including a study of the extractable amount of the contaminant versus the time elapsed between spiking and the extraction of the sample. This study can become an element of the validation package of the method.

  18. Real-time contaminant sensing and control in civil infrastructure systems

    NASA Astrophysics Data System (ADS)

    Rimer, Sara; Katopodes, Nikolaos

    2014-11-01

    A laboratory-scale prototype has been designed and implemented to test the feasibility of real-time contaminant sensing and control in civil infrastructure systems. A blower wind tunnel is the basis of the prototype design, with propylene glycol smoke as the ``contaminant.'' A camera sensor and compressed-air vacuum nozzle system is set up at the test section portion of the prototype to visually sense and then control the contaminant; a real-time controller is programmed to read in data from the camera sensor and administer pressure to regulators controlling the compressed air operating the vacuum nozzles. A computational fluid dynamics model is being integrated in with this prototype to inform the correct pressure to supply to the regulators in order to optimally control the contaminant's removal from the prototype. The performance of the prototype has been evaluated against the computational fluid dynamics model and is discussed in this presentation. Furthermore, the initial performance of the sensor-control system implemented in the test section of the prototype is discussed. NSF-CMMI 0856438.

  19. Overview of the International Space Station System Level Trace Contaminant Injection Test

    NASA Technical Reports Server (NTRS)

    Tatara, James D.; Perry, Jay L.; Franks, Gerald D.

    1997-01-01

    Trace contaminant control onboard the International Space Station will be accomplished not only by the Trace Contaminant Control Subassembly but also by other Environmental Control and Life Support System subassemblies. These additional removal routes include absorption by humidity condensate in the Temperature and Humidity Control Condensing Heat Exchanger and adsorption by the Carbon Dioxide Removal Assembly. The Trace Contaminant Injection Test, which was performed at NASA's Marshall Space Flight Center, investigated the system-level removal of trace contaminants by the International Space Station Atmosphere Revitalization, and Temperature/Humidity Control Subsystems, (November-December 1997). It is a follow-on to the Integrated Atmosphere Revitalization Test conducted in 1996. An estimate for the magnitude of the assisting role provided by the Carbon Dioxide Removal Assembly and the Temperature and Humidity Control unit was obtained. In addition, data on the purity of Carbon Dioxide Removal Assembly carbon dioxide product were obtained to support Environmental Control and Life Support System Air Revitalization Subsystem loop closure.

  20. Implementation of the TOMS contamination control requirements in the former USSR

    NASA Technical Reports Server (NTRS)

    Abrams, Eve M.

    1992-01-01

    The American Total Ozone Mapping Spectrometer (TOMS) was integrated with the Russian Meteor-3 spacecraft and launched on August 15, 1991. Although the TOMS instrument was sensitive to both particulate and molecular contamination, the program for Meteor-3 had not formerly addressed contamination control in ground operations. In order to accommodate the TOMS cleanliness requirements, a contamination control program was successfully established from inception at both the Meteor-3 spacecraft plant near Moscow and at the launch site in Plesetsk.

Top