Sample records for contamination control unit

  1. Estimating aquatic toxicity as determined through laboratory tests of great lakes sediments containing complex mixtures of environmental contaminants

    USGS Publications Warehouse

    1996-01-01

    We developed and evaluated a total toxic units modeling approach for predicting mean toxicity as measured in laboratory tests for Great Lakes sediments containing complex mixtures of environmental contaminants (e.g., polychlorinated biphenyls, polycyclic aromatic hydrocarbons, pesticides, chlorinated dioxins, and metals). The approach incorporates equilibrium partitioning and organic carbon control of bioavailability for organic contaminants and acid volatile sulfide (AVS) control for metals, and includes toxic equivalency for planar organic chemicals. A toxic unit is defined as the ratio of the estimated pore-water concentration of a contaminant to the chronic toxicity of that contaminant, as estimated by U.S. Environmental Protection Agency Ambient Water Quality Criteria (AWQC). The toxic unit models we developed assume complete additivity of contaminant effects, are completely mechanistic in form, and were evaluated without any a posteriori modification of either the models or the data from which the models were developed and against which they were tested. A linear relationship between total toxic units, which included toxicity attributable to both iron and un-ionized ammonia, accounted for about 88% of observed variability in mean toxicity; a quadratic relationship accounted for almost 94%. Exclusion of either bioavailability components (i.e., equilibrium partitioning control of organic contaminants and AVS control of metals) or iron from the model substantially decreased its ability to predict mean toxicity. A model based solely on un-ionized ammonia accounted for about 47% of the variability in mean toxicity. We found the toxic unit approach to be a viable method for assessing and ranking the relative potential toxicity of contaminated sediments.

  2. Effects of iodine in microbial control of dental treatment water.

    PubMed

    Puttaiah, Raghunath; Seibert, Jeff; Spears, Robert

    2011-05-01

    To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization.

  3. Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.

    2004-01-01

    Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST &om contamination and the instruments from self-contamination.

  4. Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Townsend, Jacqueline A.; Hedgeland, Randy J.

    2004-01-01

    Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST from contamination and the instruments from self-contamination.

  5. Effects of Hydrogen Peroxide on Dental Unit Biofilms and Treatment Water Contamination

    PubMed Central

    Lin, Shih-Ming; Svoboda, Kathy K.H.; Giletto, Anthony; Seibert, Jeff; Puttaiah, Raghunath

    2011-01-01

    Objectives: To study effects of various concentrations of hydrogen peroxide on mature waterline biofilms and in controlling planktonic (free-floating) organisms in simulated dental treatment water systems; and to study in vitro the effects of 2%, 3%, and 7% hydrogen peroxide on the removal of mature biofilms and inorganic compounds in dental waterlines. Methods: Four units of an automated dental unit water system simulation device was used for 12 weeks. All units were initially cleaned to control biofilms and inorganic deposits. H2O2 at concentrations of 1%, 2%, 3% was used weekly for periodic cleaning in three treatment group units (units 1, 2 & 3), with 0.05%, 0.15% and 0.25% H2O2 in municipal water used as irrigant respectively. The control unit (unit 4) did not have weekly cleanings and used municipal water as irrigant. Laser Scanning Confocal Microscopy and Scanning Electron Microscopy were used to study deposits on lines, and weekly heterotrophic plate counts done to study effluent water contamination. A 24 hour in vitro challenge test with 7%, 3% and 2% H2O2 on mature biofilms was conducted using harvested waterlines to study biofilm and inorganic deposit removal. Results: Heterotrophic plate counts of effluent water showed that the control unit reached contamination levels in excess of 400,000 CFU/mL while all treatment units showed contamination levels <500 CFU/mL through most of the 12 weeks. All treatment units showed varying levels of biofilm and inorganic deposit control in this short 12 week study. The in vitro challenge test showed although there was biofilm control, there was no eradication even when 7% H2O2 was used for 24 hours. Conclusions: 2% H2O2 used as a periodic cleaner, and diluted to 0.05% in municipal water for irrigation was beneficial in controlling biofilm and planktonic contamination in dental unit water systems. However, to remove well established biofilms, it may take more than 2 months when initial and multiple periodic cleanings are performed using H2O2. PMID:21228956

  6. Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

    NASA Technical Reports Server (NTRS)

    Fay, M.

    1998-01-01

    This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

  7. Case-control study of prostatic cancer in employees of the United Kingdom Atomic Energy Authority.

    PubMed Central

    Rooney, C; Beral, V; Maconochie, N; Fraser, P; Davies, G

    1993-01-01

    OBJECTIVE--To investigate the relation between risk of prostatic cancer and occupational exposures, especially to radionuclides, in employees of the United Kingdom Atomic Energy Authority. DESIGN--Case-control study of men with prostatic cancer and matched controls. Information about sociodemographic factors and exposures to radionuclides and other substances was abstracted and classified for each subject from United Kingdom Atomic Energy Authority records without knowledge of who had cancer. SUBJECTS--136 men with prostatic cancer diagnosed between 1946 and 1986 and 404 matched controls, all employees of United Kingdom Atomic Energy Authority. MAIN OUTCOME MEASURES--Documented or possible contamination with specific radionuclides. RESULTS--Risk of prostatic cancer was significantly increased in men who were internally contaminated with or who worked in environments potentially contaminated by tritium, chromium-51, iron-59, cobalt-60, or zinc-65. Internal contamination with at least one of the five radionuclides was detected in 14 men with prostatic cancer (10%) and 12 controls (3%) (relative risk 5.32 (95% confidence interval 1.87 to 17.24). Altogether 28 men with prostatic cancer (21%) and 46 controls (11%) worked in environments potentially contaminated by at least one of the five radionuclides (relative risk 2.36 (1.26 to 4.43)); about two thirds worked at heavy water reactors (19 men with prostatic cancer and 32 controls (relative risk 2.13 (1.00 to 4.52)). Relative risk of prostatic cancer increased with increasing duration of work in places potentially contaminated by these radionuclides and with increasing level of probable contamination. Prostatic cancer was not associated with exposure to plutonium, uranium, cadmium, boron, beryllium, or organic or inorganic chemicals. CONCLUSIONS--Risk of prostatic cancer risk was increased in United Kingdom Atomic Energy Authority workers who were occupationally exposed to tritium, 51Cr, 59Fe, 60Co, or 65Zn. Exposure to these radionuclides was infrequent, and their separate effects could not be evaluated. PMID:8274891

  8. Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    1994-01-01

    A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

  9. Superfund record of decision (EPA Region 6): Southern Shipbuilding Corp., Slidell, LA, July 20, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This decision document presents the selected remedial action for the source control operable unit of the Southern Shipbuilding Corporation (SSC) site in Slidell, Louisiana. This remedy represents the source control operable unit which addresses remediation of highly contaminated sludge and soil, the marginally contaminated soil, and the graving dock sediments at the Southern Shipbuilding Corporation site.

  10. Contamination analysis unit

    DOEpatents

    Gregg, H.R.; Meltzer, M.P.

    1996-05-28

    The portable Contamination Analysis Unit (CAU) measures trace quantities of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surfaces by measuring residual hazardous surface contamination, such as tritium and trace organics. It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings. 1 fig.

  11. Contamination analysis unit

    DOEpatents

    Gregg, Hugh R.; Meltzer, Michael P.

    1996-01-01

    The portable Contamination Analysis Unit (CAU) measures trace quantifies of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surface by measuring residual hazardous surface contamination, such as tritium and trace organics It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings.

  12. Implications of Bt traits on mycotoxin contamination in maize: Overview and recent experimental results in southern United States.

    PubMed

    Abbas, Hamed K; Zablotowicz, Robert M; Weaver, Mark A; Shier, W Thomas; Bruns, H Arnold; Bellaloui, Nacer; Accinelli, Cesare; Abel, Craig A

    2013-12-04

    Mycotoxin contamination levels in maize kernels are controlled by a complex set of factors including insect pressure, fungal inoculum potential, and environmental conditions that are difficult to predict. Methods are becoming available to control mycotoxin-producing fungi in preharvest crops, including Bt expression, biocontrol, and host plant resistance. Initial reports in the United States and other countries have associated Bt expression with reduced fumonisin, deoxynivalenol, and zearalenone contamination and, to a lesser extent, reduced aflatoxin contamination in harvested maize kernels. However, subsequent field results have been inconsistent, confirming that fumonisin contamination can be reduced by Bt expression, but the effect on aflatoxin is, at present, inconclusive. New maize hybrids have been introduced with increased spectra of insect control and higher levels of Bt expression that may provide important tools for mycotoxin reduction and increased yield due to reduced insect feeding, particularly if used together with biocontrol and host plant resistance.

  13. System to control contamination during retrieval of buried TRU waste

    DOEpatents

    Menkhaus, Daniel E.; Loomis, Guy G.; Mullen, Carlan K.; Scott, Donald W.; Feldman, Edgar M.; Meyer, Leroy C.

    1993-01-01

    A system to control contamination during the retrieval of hazardous waste comprising an outer containment building, an inner containment building, within the outer containment building, an electrostatic radioactive particle recovery unit connected to and in communication with the inner and outer containment buildings, and a contaminate suppression system including a moisture control subsystem, and a rapid monitoring system having the ability to monitor conditions in the inner and outer containment buildings.

  14. System to control contamination during retrieval of buried TRU waste

    DOEpatents

    Menkhaus, D.E.; Loomis, G.G.; Mullen, C.K.; Scott, D.W.; Feldman, E.M.; Meyer, L.C.

    1993-04-20

    A system is described to control contamination during the retrieval of hazardous waste comprising an outer containment building, an inner containment building, within the outer containment building, an electrostatic radioactive particle recovery unit connected to and in communication with the inner and outer containment buildings, and a contaminate suppression system including a moisture control subsystem, and a rapid monitoring system having the ability to monitor conditions in the inner and outer containment buildings.

  15. Superfund record of decision (EPA Region 7): Cornhusker Army Ammunition Plant, Operable Unit 1, Hall County, Grand Island, NE, September 29, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-04-01

    The decision document presents the selected interim remedial action for the groundwater operable unit at the Cornhusker Army Ammunition Plant (CAAP). Operable Unit One encompasses the explosives groundwater plume(s), both on-post and off-post. Explosives of concern in the contaminant plume include RDX, TNT, HMX, and their decomposition products. The objective of the interim action is to contain the plume and prevent further migration of contaminants, and does not encompass full restoration of the plume of contaminated groundwater. The recommended alternatives provide an approach to containing and removing contaminant mass from the groundwater plume. This approach will control further migration ofmore » the plume and reduce the levels of the contamination in groundwater.« less

  16. Disinfection of contaminated water by using solar irradiation.

    PubMed

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  17. Superfund record of decision (EPA Region 5): Skinner Landfill, West Chester, OH, June 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-06-04

    The decision document presents the selected final remedial action for the Skinner Landfill site in West Chester, Ohio. The remedy is the second and final of two operable units for this site. The first operable unit addressed immediate site concerns, through the construction of a fence around the contaminated area, and by offering an alternate supply of drinking water to the potentially affected users of groundwater. This final operable unit addresses potential future migration of site contaminants into the groundwater and will limit the potential for direct exposure of site contaminants to humans through source control measures.

  18. Contamination control concepts for space station customer servicing

    NASA Technical Reports Server (NTRS)

    Maruya, K. A.; Ryan, L. E.; Rosales, L. A.; Medler, E. H.

    1986-01-01

    The customer servicing operations envisioned for the space station, which include instrument repair, orbital replacement unit (ORU) changeout, and fluid replenishment for free-flying and attached payloads, are expected to create requirements for a unique contamination control subsystem for the customer servicing facility (CSF). Both the core space station and the CSF users present unique requirements/sensitivities, not all of which are currently defined with common criteria. Preliminary results from an assessment of the effects of the CSF-induced contamination environment are reported. Strategies for a comprehensive contamination control approach and a description of specific hardware devices and their applicability are discussed.

  19. Nosocomial Serratia marcescens infections associated with extrinsic contamination of a liquid nonmedicated soap.

    PubMed

    Sartor, C; Jacomo, V; Duvivier, C; Tissot-Dupont, H; Sambuc, R; Drancourt, M

    2000-03-01

    To determine the role of nonmedicated soap as a source of Serratia marcescens nosocomial infections (NIs) in hospital units with endemic S marcescens NI and to examine the mechanisms of soap colonization. University-affiliated tertiary-care hospitals. A prospective case-control study and an environmental investigation were performed to assess the relationship between S marcescens NIs in hospital units and S marcescens-contaminated soap. Soap-bottle use and handwashing practices were reviewed. Cultures of healthcare workers' (HCWs) hands were obtained before and after hand washing with soap. 5 of 7 hospital units with S marcescens NIs had soap bottles contaminated with S marcescens, compared to 1 of 14 other units (P=.006). After hand washing with an S marcescens-contaminated soap pump, HCWs' hands were 54 times more likely to be contaminated with S marcescens (P<.001). Extrinsic contamination of a non-medicated liquid soap by S marcescens resulted in handborne transmission of S marcescens NIs by HCWs in our setting. This finding led to the application of strict guidelines for nonmedicated soap use and to the reinforcement of alcoholic hand disinfection.

  20. Microbial contamination of dental unit waterlines and effect on quality of indoor air.

    PubMed

    Kadaifciler, Duygu Göksay; Cotuk, Aysin

    2014-06-01

    The microbiological quality in dental unit waterlines (DUWLs) is considered to be important because patients and dental staff with suppressed immune systems are regularly exposed to water and aerosols generated from dental units (DUs). Opportunistic pathogens like Pseudomonas, Legionella, Candida, and Aspergillus can be present in DUWLs, while during consultations, bioaerosols can be dispersed in the air, thus resulting in effects on microbiological quality of indoor air. This present study represents microbiological air and water quality in dental offices (DOs) and also concerns the relationship between the quality of DO air and dental unit water. This study aimed to assess both the microbial quality of dental unit water and the indoor air in 20 DOs and to survey the effect on the quality of the indoor air with the existing microorganisms in dental unit water. Fourteen out of 20 (70 %) DUWLs were found to be contaminated with a high number of aerobic mesophilic heterotrophic bacteria. In terms of bacterial air contamination levels, in 90 % of DOs, a medium level (<500 colony-forming units (CFU)/m(3)) of contamination was determined, while in terms of microfungal air contamination, in all DOs, a low level (<100 CFU/m(3)) of contamination was determined. Potential infection or allergen agents, such as Pseudomonas, Micrococcus, Staphylococcus, Alternaria, Cladosporium, Penicillium, Aspergillus, and Paecilomyces were isolated from water and air samples. This study's determination of contamination sources and evaluation of microbial load in DOs could contribute to the development of quality control methods in the future.

  1. Disinfection of Contaminated Water by Using Solar Irradiation

    PubMed Central

    Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad

    2004-01-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599

  2. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines

    PubMed Central

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-01-01

    Background: It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. Materials and Methods: In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann — Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. Results: All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. Conclusion: The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines. PMID:25097645

  3. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines.

    PubMed

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-05-01

    It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann - Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines.

  4. Remedial Action Report for Operable Units 6-05 and 10-04, Phase III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. P. Wells

    2007-08-15

    This Phase III remedial action report addresses the remediation of lead-contaminated soils found at the Security Training Facility STF-02 Gun Range at the Idaho National Laboratory Site. Phase I, consisting of developing and implementing institutional controls at Operble Unit 10-04 sites and developing and implementing Idaho National Laboratory Site-wide plans for both institutional controls and ecological monitoring, was addressed in a previous report. Phase II will remediate sites contaminated with trinitrotoluene and Royal Demolition Explosive. Phase IV will remediate hazards from unexploded ordnance.

  5. The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples.

    EPA Science Inventory

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods w...

  6. Environmental E.coli isolate characterization and selection as improved indicators for pathogens associated with produce contamination

    USDA-ARS?s Scientific Manuscript database

    Contamination of food and water by pathogens is a substantial public health issue in the United States. According to the Centers for Disease Control and Prevention, 49% of foodborne illness is caused by produce, and despite efforts to reduce produce contamination, these issues persist. Escherichia c...

  7. Overview of the International Space Station System Level Trace Contaminant Injection Test

    NASA Technical Reports Server (NTRS)

    Tatara, James D.; Perry, Jay L.; Franks, Gerald D.

    1997-01-01

    Trace contaminant control onboard the International Space Station will be accomplished not only by the Trace Contaminant Control Subassembly but also by other Environmental Control and Life Support System subassemblies. These additional removal routes include absorption by humidity condensate in the Temperature and Humidity Control Condensing Heat Exchanger and adsorption by the Carbon Dioxide Removal Assembly. The Trace Contaminant Injection Test, which was performed at NASA's Marshall Space Flight Center, investigated the system-level removal of trace contaminants by the International Space Station Atmosphere Revitalization, and Temperature/Humidity Control Subsystems, (November-December 1997). It is a follow-on to the Integrated Atmosphere Revitalization Test conducted in 1996. An estimate for the magnitude of the assisting role provided by the Carbon Dioxide Removal Assembly and the Temperature and Humidity Control unit was obtained. In addition, data on the purity of Carbon Dioxide Removal Assembly carbon dioxide product were obtained to support Environmental Control and Life Support System Air Revitalization Subsystem loop closure.

  8. A re-evaluation of a case-control model with contaminated controls for resource selection studies

    Treesearch

    Christopher T. Rota; Joshua J. Millspaugh; Dylan C. Kesler; Chad P. Lehman; Mark A. Rumble; Catherine M. B. Jachowski

    2013-01-01

    A common sampling design in resource selection studies involves measuring resource attributes at sample units used by an animal and at sample units considered available for use. Few models can estimate the absolute probability of using a sample unit from such data, but such approaches are generally preferred over statistical methods that estimate a relative probability...

  9. Review of mobile communication devices as potential reservoirs of nosocomial pathogens.

    PubMed

    Brady, R R W; Verran, J; Damani, N N; Gibb, A P

    2009-04-01

    Innovation in mobile communication technology has provided novel approaches to the delivery of healthcare and improvements in the speed and quality of routine medical communication. Bacterial contamination of mobile communication devices (MCDs) could be an important issue affecting the implementation of effective infection control measures and might have an impact on efforts to reduce cross-contamination. This review examines recent studies reporting bacterial contamination of MCDs, most demonstrating that 9-25% of MCDs are contaminated with pathogenic bacteria. We examine previously investigated risk factors for MCD contamination in addition to work on surface decontamination of the device. Recommendations to reduce contamination risks include staff education, strict hand hygiene measures, guidelines on device cleaning and consideration of the restrictions regarding use of mobile phone technology in certain high risk areas, for example, operating theatres, intensive care units and burns units. Further work is required to evaluate the benefit of such interventions on MCD contamination and to determine whether a link exists between contamination and subsequent patient infection.

  10. Superfund record of decision (EPA Region 3): US Defense General Supply Center (DLA), operable unit 3, Chesterfield County, Richmond, VA, September 29, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This decision document presents the selected remedial action for the National Guard Source Area (NGA), Operable Unit (OU3) at the Defense General Supply Center (DGSC) in Richmond, Virginia. Operable Unit 3 addresses the contaminated soils at the National Guard . The selected alternative requires that institutional controls, including access restriction, property transfer restriction, and preconstruction assessment, be implemented or continued at the site. Also, contaminated soils posing human health risks will be excavated and disposed of.

  11. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  12. Atoxigenic strains of Aspergillus flavus isolated from peanuts collected from northern Philippines as potential biocon agents against pre-harvest aflatoxin contamination of peanut and corn

    USDA-ARS?s Scientific Manuscript database

    Aflatoxin contamination of food products causes liver cancer and weakened immunity in humans, and stunted growth and reduced productivity in animals (CAST, 2003). Effective control of pre-harvest aflatoxin contamination of peanut and corn due to AflaGuard and Aflasafe in the United States and Africa...

  13. The detection of blood on dental surgery surfaces and equipment following dental hygiene treatment.

    PubMed

    McColl, E; Bagg, J; Winning, S

    1994-01-22

    The Kastle-Meyer technique, a forensic test for blood, has been employed to assess the frequency and potential routes of contamination by blood between patients, staff and equipment during routine dental hygiene treatment. Fifty treatment sessions were studied and units were cleaned between patients according to the current hospital protocol. The surfaces most frequently contaminated after treatment were the 3-in-1 syringe buttons (40%), protective bibs (22%), tap handles (20%), light handles (18%) and operating cart handles (16%). Following cleaning of the units, the surfaces remaining contaminated were the 3-in-1 syringes (10%), tap handles (4%) and cart handles (2%). Modifications to the cross-infection control protocol have been made to eliminate these sources of contamination.

  14. Salmonellosis outbreaks in the United States due to fresh produce: sources and potential intervention measures.

    PubMed

    Hanning, Irene B; Nutt, J D; Ricke, Steven C

    2009-01-01

    Foodborne Salmonella spp. is a leading cause of foodborne illness in the United States each year. Traditionally, most cases of salmonellosis were thought to originate from meat and poultry products. However, an increasing number of salmonellosis outbreaks are occurring as a result of contaminated produce. Several produce items specifically have been identified in outbreaks, and the ability of Salmonella to attach or internalize into vegetables and fruits may be factors that make these produce items more likely to be sources of Salmonella. In addition, environmental factors including contaminated water sources used to irrigate and wash produce crops have been implicated in a large number of outbreaks. Salmonella is carried by both domesticated and wild animals and can contaminate freshwater by direct or indirect contact. In some cases, direct contact of produce or seeds with contaminated manure or animal wastes can lead to contaminated crops. This review examines outbreaks of Salmonella due to contaminated produce, the potential sources of Salmonella, and possible control measures to prevent contamination of produce.

  15. Two-Year Systematic Study To Assess Norovirus Contamination in Oysters from Commercial Harvesting Areas in the United Kingdom

    PubMed Central

    Gustar, Nicole E.; Powell, Andrew L.; Hartnell, Rachel E.; Lees, David N.

    2012-01-01

    The contamination of bivalve shellfish with norovirus from human fecal sources is recognized as an important human health risk. Standardized quantitative methods for the detection of norovirus in molluscan shellfish are now available, and viral standards are being considered in the European Union and internationally. This 2-year systematic study aimed to investigate the impact of the application of these methods to the monitoring of norovirus contamination in oyster production areas in the United Kingdom. Twenty-four monthly samples of oysters from 39 United Kingdom production areas, chosen to represent a range of potential contamination risk, were tested for norovirus genogroups I and II by using a quantitative real-time reverse transcription (RT)-PCR method. Norovirus was detected in 76.2% (643/844) of samples, with all sites returning at least one positive result. Both prevalences (presence or absence) and norovirus levels varied markedly between sites. However, overall, a marked winter seasonality of contamination by both prevalence and quantity was observed. Correlations were found between norovirus contamination and potential risk indicators, including harvesting area classifications, Escherichia coli scores, and environmental temperatures. A predictive risk score for norovirus contamination was developed by using a combination of these factors. In summary, this study, the largest of its type undertaken to date, provides a systematic analysis of norovirus contamination in commercial oyster production areas in the United Kingdom. The data should assist risk managers to develop control strategies to reduce the risk of human illness resulting from norovirus contamination of bivalve molluscs. PMID:22685151

  16. TREATABILITY STUDY BULLETIN: MOBILE VOLUME REDUCTION UNIT AT THE SAND CREEK SUPERFUND SITE

    EPA Science Inventory

    The Risk Reduction Engineering Laboratory (RREL) Releases Control Branch (RCB) has developed a pilot-scale Mobile Volume Reduction Unit (VRU) to determine the feasibility of soil washing for the remediation of contaminated soils. This mobile unit, mounted on two trailers, can pro...

  17. SEPTIC TANK SETBACK DISTANCES: A WAY TO MINIMIZE VIRUS CONTAMINATION OF DRINKING WATER

    EPA Science Inventory

    Septic tanks are the most frequently reported causes of contamination in ground-water disease outbreaks associated with the consumption of untreated ground water in the United States. The placement of septic tanks is generally controlled by county-wide or state-wide regulations, ...

  18. 40 CFR 422.41 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... contaminated nonprocess waste water, as defined below. (c) The term contaminated non-process waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  19. 40 CFR 422.51 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... contaminated non-process waste water, as defined below. (c) The term contaminated nonprocess waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  20. 40 CFR 422.41 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... contaminated nonprocess waste water, as defined below. (c) The term contaminated non-process waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  1. 40 CFR 422.51 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... include contaminated non-process waste water, as defined below. (c) The term contaminated nonprocess waste..., reduce, eliminate and control to the maximum extent feasible such contact and provided further that all..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  2. 40 CFR 422.51 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contaminated non-process waste water, as defined below. (c) The term contaminated nonprocess waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  3. 40 CFR 422.41 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... contaminated nonprocess waste water, as defined below. (c) The term contaminated non-process waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  4. 40 CFR 422.51 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... contaminated non-process waste water, as defined below. (c) The term contaminated nonprocess waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  5. 40 CFR 422.41 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contaminated nonprocess waste water, as defined below. (c) The term contaminated non-process waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  6. 40 CFR 422.51 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... contaminated non-process waste water, as defined below. (c) The term contaminated nonprocess waste water shall..., eliminate and control to the maximum extent feasible such contact and provided further that all reasonable..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  7. 40 CFR 422.41 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... include contaminated nonprocess waste water, as defined below. (c) The term contaminated non-process waste..., reduce, eliminate and control to the maximum extent feasible such contact and provided further that all..., “Rainfall Frequency Atlas of the United States,” May 1961, and subsequent amendments or equivalent regional...

  8. Comparison of the ActiDes-Blue and CARELA HYDRO-DES technology for the sanitation of contaminated cooling water systems in dental units.

    PubMed

    Kramer, Axel; Lemanski, Sandra; Demond, Kathleen; Assadian, Ojan

    2012-01-01

    The hygienic-microbiological control of 6 dental units being in use for the past 16 years revealed a significantly increased microbial contamination of their cooling water system. In order to comply with the requirements of the drinking water directive ("Trinkwasserverordnung"), the commercially available production system ActiDes, producing on-site ActiDes-Blue which is based on hypochlorous acid (HOCl) and generated by anodic oxidation, was investigated. Water samples from the 6 contaminated dental units were examined for the total number of colony forming units (cfu), contamination with molds, L. pneumophila and P. aeruginosa. The control period for the total colony count was 4 weeks (8 samples/unit). The subsequent application phase of the ActiDes-Blue procedure was 6 months (31 samples/unit). Additionally, the redox potential and the pH value were measured.Futhermore, the decontamination agent CARELA HYDRO-DES, a two component agent based on H(2)O(2) with the addition of a mixture of sodium hydrogen sulphate and sulphuric acid in an aqueous solution effective at 0.1% and higher, was applied in a unit that had been put out of service for a month before. Before application, the system was first filled with a 5% solution of the alkaline pre-cleaning agent CARELA Solvent for bacterial slime; the system was left with this solution for 1 h. The pre-cleaning agent was then completely displaced from the system with tap water and a decontaminating solution of 5% CARELA HYDRO-DES and left in place for 1 h. Drinking water quality level was reached only twice during the control phase. The average values of the dental units ranged between 3,633 CFU/ml and 29,417 c/ml. During the application phase, drinking water level could be achieved in 11 water samples. In another 6 water samples a total colony count of <150 cfu/ml was reached. The average values for the dental units' total colony count ranged between 529 cfu/ml and 87,450 cfu/ml. No significant differences between the control phase and the action phase could be demonstrated. During the control phase, contamination of the water samples with a mold was noticed so that examinations for molds were carried out beyond the scope of the drinking water directive. For this parameter as well, no significant differences between the phases of the study could be shown.The Legionella load of the dental units was low. L. pneumophila were yielded in only 4 out of 130 water samples. During the control phase, twice colony counts at 50 cfu/1,000 ml and 110 cfu/1,000 ml were measured. During the action phase, counts with Legionella spp. could be measured at 5 cfu/1,000 ml for one unit only. Also, with 1-10 cfu/100 ml, the P. aeruginosa contamination was low. During the application phase, it ranged between 0-7 cfu/100 ml.Redox potential and pH value showed a slight decrease during the application phase.Before treatment with CARELA Solvent and CARELA HYDRO-DES, the initial contamination of the total count of bacterial colonies was 1,432 cfu/ml at 22°C and 846 cfu/ml at 36°C as well as >1,000 cfu/100 ml for molds. 1 h after the decontamination, no bacteria and molds could be detected in 1,000 ml of tap water. Despite the fact that the unit was not used any longer, after 7 d the bacterial colony count was 3 cfu/ml at 22°C and 2 cfu/ml at 36°C while molds could not be detected. Even after a rest time of 14 d only 167 cfu/ml or 42 cfu/ml could be yielded. Molds were further not cultivable. A material damage could not be observed. Pertaining to the ActiDes technology's effectiveness, it has to be pointed out that the dental units investigated were those used for dental students' teaching and therefore were clearly less frequently used than clinically used units in a dental practice. This resulted in distinctly longer stagnation periods which favored formation of biofilms. In summary, the ActiDes technology and ActiDes-Blue showed not to be sufficiently effective for the sanitation of contaminated water reservoirs in dental units under aggravated conditions of repeated and longer periods of non-use in connection with longer water stagnation periods. In comparison, the biofilm was sustainably eliminated through the combined application of CARELA(®) Solvent for Bacterial Slime with subsequent decontamination using CARELA(®) HYDRO-DES.

  9. Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

    PubMed

    Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino

    2010-12-01

    Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.

  10. Pilot-scale treatability test plan for the 200-BP-5 operable unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in thismore » test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.« less

  11. Contamination of dental unit water and air outlets following use of clean head system and conventional handpieces.

    PubMed

    Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian

    2007-01-01

    Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

  12. Impact of a risk management plan on Legionella contamination of dental unit water.

    PubMed

    Leoni, Erica; Dallolio, Laura; Stagni, Francesca; Sanna, Tiziana; D'Alessandro, Giovanni; Piana, Gabriela

    2015-02-23

    The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.

  13. Hydrogeology and soil gas at J-Field, Aberdeen Proving Ground, Maryland

    USGS Publications Warehouse

    Hughes, W.B.

    1993-01-01

    Disposal of chemical warfare agents, munitions, and industrial chemicals in J-Field, Aberdeen Proving Ground, Maryland, has contaminated soil, groundwater and surface water. Seven exploratory borings and 38 observation wells were drilled to define the hydrogeologic framework at J-Field and to determine the type, extent, and movement of contaminants. The geologic units beneath J-Field consist of Coastal Plain sediments of the Cretaceous Patapsco Formation and Pleistocene Talbot Formation. The Patapsco Formation contains several laterally discontinuous aquifers and confining units. The Pleistocene deposits were divided into 3 hydrogeologic units--a surficial aquifer, a confining unit, and a confined aquifer. Water in the surficial aquifer flows laterally from topographically high areas to discharge areas in marshes and streams, and vertically to the underlying confined aquifer. In offshore areas, water flows from the deeper confined aquifers upward toward discharge areas in the Gunpowder River and Chesapeake Bay. Analyses of soil-gas samples showed high relative-flux values of chlorinated solvents, phthalates, and hydrocarbons at the toxic-materials disposal area, white-phosphorus disposal area, and riot-control-agent disposal area. The highest flux values were located downgradient of the toxic materials and white phosphorus disposal areas, indicating that groundwater contaminants are moving from source areas beneath the disposal pits toward discharge points in the marshes and estuaries. Elevated relative-flux values were measured upgradient and downgradient of the riot-control agent disposal area, and possibly result from soil and (or) groundwater contamination.

  14. Superfund Record of Decision (EPA Region 4): Murray-Ohio Dump, Operable Unit 1, Lawrence County, Lawrenceburg, TN, June 17, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-02-01

    This decision document represents the selected remedial action for the Murray Ohio Dump Site. This final remedy addresses remediation of ground-water/seep contamination and soil contamination by eliminating or reducing the risks posed by the Site, through treatment, engineering and institutional controls.

  15. Potential Effectiveness of Point-of-Use Filtration to Address Risks to Drinking Water in the United States

    PubMed Central

    Brown, Kathleen Ward; Gessesse, Bemnet; Butler, Lindsey J; MacIntosh, David L

    2017-01-01

    Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while “in use” focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells. PMID:29270018

  16. Potential Effectiveness of Point-of-Use Filtration to Address Risks to Drinking Water in the United States.

    PubMed

    Brown, Kathleen Ward; Gessesse, Bemnet; Butler, Lindsey J; MacIntosh, David L

    2017-01-01

    Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while "in use" focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells.

  17. Estimating changes in public health following implementation of hazard analysis and critical control point in the United States broiler slaughter industry.

    PubMed

    Williams, Michael S; Ebel, Eric D

    2012-01-01

    A common approach to reducing microbial contamination has been the implementation of a Hazard Analysis and Critical Control Point (HACCP) program to prevent or reduce contamination during production. One example is the Pathogen Reduction HACCP program implemented by the U.S. Department of Agriculture's Food Safety and Inspection Service (FSIS). This program consisted of a staged implementation between 1996 and 2000 to reduce microbial contamination on meat and poultry products. Of the commodities regulated by FSIS, one of the largest observed reductions was for Salmonella contamination on broiler chicken carcasses. Nevertheless, how this reduction might have influenced the total number of salmonellosis cases in the United States has not been assessed. This study incorporates information from public health surveillance and surveys of the poultry slaughter industry into a model that estimates the number of broiler-related salmonellosis cases through time. The model estimates that-following the 56% reduction in the proportion of contaminated broiler carcasses observed between 1995 and 2000-approximately 190,000 fewer annual salmonellosis cases (attributed to broilers) occurred in 2000 compared with 1995. The uncertainty bounds for this estimate range from approximately 37,000 to 500,000 illnesses. Estimated illnesses prevented, due to the more modest reduction in contamination of 13% between 2000 and 2007, were not statistically significant. An analysis relating the necessary magnitude of change in contamination required for detection via human surveillance also is provided.

  18. Regenerable Air Purification System for Gas-Phase Contaminant Control

    NASA Technical Reports Server (NTRS)

    Constantinescu, Ileana C.; Finn, John E.; LeVan, M. Douglas; Lung, Bernadette (Technical Monitor)

    2000-01-01

    Tests of a pre-prototype regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an adsorbent column have been performed at NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. During the normal operation mode, contaminants are removed from the air on the column. Regeneration of the column is performed on-line. During regeneration, contaminants are displaced and destroyed inside the closed oxidation loop. In this presentation we discuss initial experimental results for the performance of RAPS in the removal and treatment of several important spacecraft contaminant species from air.

  19. Purge- and intensive-purge decontamination of dental units contaminated with biofilm

    PubMed Central

    Kramer, Axel; Assadian, Ojan; Bachfeld, Danny; Meyer, Georg

    2012-01-01

    Introduction: During hygienic-microbiological monitoring of the water quality in dental units, the total bacterial colony count was found to exceed the limits for drinking water quality; in addition, mold contamination was detected. The presumed cause was irregular decontamination of the units through purging and intensive decontamination. Methods: To decontaminate the units, the manufacturer’s recommended program for cleaning and intensive decontamination was intensified by shortened intervals over a 2-week period. For Sirona units, instead of once a day, the automatic purge program was run every morning and evening for 20 min each time, and instead of once a month, intensive decontamination was performed every two weeks; this schedule has been maintained since then. For KaVo units, cleaning with the hydroclean function was carried out for 2.5 min every morning and evening. The automatic intensive decontamination was run daily instead of weekly. A maintenance log book was introduced, in which decontamination/cleaning was confirmed by the operator’s signature. Results: Within 5 weeks, all previously contaminated units were decontaminated. Discussion: By shortening the cleaning and intensive decontamination intervals in a 2-week period with subsequent control that the recommended maintenance intervals were kept, it was possible to guarantee drinking-water quality in the dental units of both manufacturers. PMID:22558045

  20. The quality of our Nation's waters: Water quality in principal aquifers of the United States, 1991-2010

    USGS Publications Warehouse

    DeSimone, Leslie A.; McMahon, Peter B.; Rosen, Michael R.

    2015-01-01

    About 130 million people in the United States rely on groundwater for drinking water, and the need for high-quality drinking-water supplies becomes more urgent as our population grows. Although groundwater is a safe, reliable source of drinking water for millions of people nationwide, high concentrations of some chemical constituents can pose potential human-health concerns. Some of these contaminants come from the rocks and sediments of the aquifers themselves, and others are chemicals that we use in agriculture, industry, and day-to-day life. When groundwater supplies are contaminated, millions of dollars can be required for treatment so that the supplies can be usable. Contaminants in groundwater can also affect the health of our streams and valuable coastal waters. By knowing where contaminants occur in groundwater, what factors control contaminant concentrations, and what kinds of changes in groundwater quality might be expected in the future, we can ensure the availability and quality of this vital natural resource in the future.

  1. The US regulatory and pharmacopeia response to the global heparin contamination crisis.

    PubMed

    Szajek, Anita Y; Chess, Edward; Johansen, Kristian; Gratzl, Gyöngyi; Gray, Elaine; Keire, David; Linhardt, Robert J; Liu, Jian; Morris, Tina; Mulloy, Barbara; Nasr, Moheb; Shriver, Zachary; Torralba, Pearle; Viskov, Christian; Williams, Roger; Woodcock, Janet; Workman, Wesley; Al-Hakim, Ali

    2016-06-09

    The contamination of the widely used lifesaving anticoagulant drug heparin in 2007 has drawn renewed attention to the challenges that are associated with the characterization, quality control and standardization of complex biological medicines from natural sources. Heparin is a linear, highly sulfated polysaccharide consisting of alternating glucosamine and uronic acid monosaccharide residues. Heparin has been used successfully as an injectable antithrombotic medicine since the 1930s, and its isolation from animal sources (primarily porcine intestine) as well as its manufacturing processes have not changed substantially since its introduction. The 2007 heparin contamination crisis resulted in several deaths in the United States and hundreds of adverse reactions worldwide, revealing the vulnerability of a complex global supply chain to sophisticated adulteration. This Perspective discusses how the US Food and Drug Administration (FDA), the United States Pharmacopeial Convention (USP) and international stakeholders collaborated to redefine quality expectations for heparin, thus making an important natural product better controlled and less susceptible to economically motivated adulteration.

  2. Bacterial Contamination of Hospital Bed-Control Handsets in a Surgical Setting: A Potential Marker of Contamination of the Healthcare Environment

    PubMed Central

    Brady, RRW; Kalima, P; Damani, NN; Wilson, RG; Dunlop, MG

    2007-01-01

    INTRODUCTION Patients undergoing colorectal surgical resections have a high incidence of surgical site infection (SSI). Many patient-specific risk factors have been recognised in association with SSI in such patients, but environmental contamination is increasingly recognised as a contributor to hospital-acquired infection (HAI). This study set out to describe the bacterial contamination of the patient environment, using hospital bed-control handsets, as they are frequently handled by both staff and patients and represent a marker of environmental contamination. PATIENTS AND METHODS On two unannounced sampling events, 1 week apart, 140 bacteriological assessments were made of 70 hospital bed control handsets within a specialist colorectal surgical unit. RESULTS Of the handsets examined, 67 (95.7%) demonstrated at least one bacterial species (52.9% grew 1, 30% grew 2 and 12.9% grew 3 or more bacterial species). Of these, 29 (41.4%) bed-control handsets grew bacteria known to cause nosocomial infection, including 22 (31.4%) handsets which grew Enterococcus spp., 9 (12.9%) which grew MRSA, 2 (2.9%) which grew MSSA, 2 (2.9%) which grew coliforms, and 1 (1.4%) handset which grew anaerobes. At 1-week follow-up, 31 bed-control handsets showed evidence of contamination by the same bacterial species. CONCLUSIONS This study revealed high levels of bacteria known to cause HAI, contaminating hospital bed-control handsets in a surgical setting. Further study is now required to confirm whether hospital environmental contamination is causally involved in SSI. PMID:17959000

  3. Overview of air biofiltration - basic technology, economics and integration with other control technologies for effective treatment of air toxics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Govind, R.; Bishop, D.F.

    1996-12-31

    This paper provides an overview of air biofiltration with experimental data on the performance of peat/compost, pelletized packed bed and structured media biofilters. It is shown that use of high surface area per unit volume structured media results in higher contaminant treatment rates per unit biofilter volume. Peat/compost biofilters exhibit lower removal efficiencies at high (> 100 ppmv) inlet contaminant concentrations and require control of media moisture content. Increase of temperature results in increasing biodegradation rates. It is shown that use of structured ceramic media allows effective control of biomass buildup by continuous removal of biomass from the biofilter mediamore » and that the biomass removal rate depends on nutrient flowrate. An experimental system is presented which enables biofilm kinetics to be determined and a simple biofilter model is developed in this paper. A group contribution approach has been developed to estimate biokinetic parameter which allows biofiltration effectiveness to be determined for a variety of volatile organic compounds (VOCs). Finally, a procedure is presented, illustrated by an example, which is used to develop an integrated process for effective treatment of air contaminants. 22 refs., 12 figs., 4 tabs.« less

  4. Environmental contaminants and the management of bat populations in the United States

    USGS Publications Warehouse

    Clark, D.R.

    1988-01-01

    Food-chain residues of organochlorine pesticides probably have been involved in declines of some U.S. bat populations; examples include free-tailed bats at Carlsbad Cavern, New Mexico, and the endangered gray bat at sites in Missouri and Alabama. If a long-lived contaminant has not been dispersed in large amounts over large areas, its impact may be controlled by administrative action that stops its use or other environmental discharge, or that results in physical isolation of localized contamination so that it no longer enters food chains

  5. Multispectral imaging system for contaminant detection

    NASA Technical Reports Server (NTRS)

    Poole, Gavin H. (Inventor)

    2003-01-01

    An automated inspection system for detecting digestive contaminants on food items as they are being processed for consumption includes a conveyor for transporting the food items, a light sealed enclosure which surrounds a portion of the conveyor, with a light source and a multispectral or hyperspectral digital imaging camera disposed within the enclosure. Operation of the conveyor, light source and camera are controlled by a central computer unit. Light reflected by the food items within the enclosure is detected in predetermined wavelength bands, and detected intensity values are analyzed to detect the presence of digestive contamination.

  6. Assessing occupational exposure to sea lamprey pesticides.

    PubMed

    Ceballos, Diana M; Beaucham, Catherine C; Kurtz, Kristine; Musolin, Kristin

    2015-01-01

    Sea lampreys are parasitic fish found in lakes of the United States and Canada. Sea lamprey is controlled through manual application of the pesticides 3-trifluoromethyl-4-nitrophenol (TFM) and Bayluscide(TM) into streams and tributaries. 3-Trifluoromethyl-4-nitrophenol may cause irritation and central nervous system depression and Bayluscide may cause irritation, dermatitis, blisters, cracking, edema, and allergic skin reactions. To assess occupational exposures to sea lamprey pesticides. We developed a wipe method for evaluating surface and skin contamination with these pesticides. This method was field tested at a biological field station and at a pesticide river application. We also evaluated exposures using control banding tools. We verified TFM surface contamination at the biological station. At the river application, we found surfaces and worker's skin contaminated with pesticides. We recommended minimizing exposures by implementing engineering controls and improved use of personal protective equipment.

  7. Adenosine Triphosphate Quantification Correlates Poorly with Microbial Contamination of Duodenoscopes.

    PubMed

    Olafsdottir, Lovisa B; Wright, Sharon B; Smithey, Anne; Heroux, Riley; Hirsch, Elizabeth B; Chen, Alice; Lane, Benjamin; Sawhney, Mandeep S; Snyder, Graham M

    2017-06-01

    OBJECTIVE The aim of this study was to quantify the correlation between adenosine triphosphate (ATP) measurements and bacterial cultures from duodenoscopes for evaluation of contamination following high-level disinfection. DESIGN Duodenoscopes used for any intended endoscopic retrograde cholangiopancreatography (ERCP) procedure were included. Microbiologic and ATP data were collected concomitantly and in the same manner from ERCP duodenoscopes. SETTING A high-volume endoscopy unit at a tertiary referral acute-care facility. METHODS Duodenoscopes were sampled for ATP and bacterial contamination in a contemporaneous and highly standardized fashion using a "flush-brush-flush" method for the working channel (WC) and a dry flocked swab for the elevator mechanism (EM). Specimens were processed for any aerobic bacterial growth (colony-forming units, CFU). Growth of CFU>0 and ATP relative light unit (RLU)>0 was considered a contaminated result. Frequency of discord between among WC and EM measurements were calculated using 2×2 contingency tables. The Spearman correlation coefficient was used to calculate the relatedness of bacterial contamination and ATP as continuous measurements. RESULTS The Spearman correlation coefficient did not demonstrate significant relatedness between ATP and CFU for either a WC or EM site. Among 390 duodenoscope sampling events, ATP and CFU assessments of contamination were discordant in 82 of 390 WC measurements (21%) and 331 of 390 of EM measurements (84.9%). The EM was frequently and markedly positive by ATP measurement. CONCLUSION ATP measurements correlate poorly with a microbiologic standard assessing duodenoscope contamination, particularly for EM sampling. ATP may reflect biological material other than nonviable aerobic bacteria and may not serve as an adequate marker of bacterial contamination. Infect Control Hosp Epidemiol 2017;38:678-684.

  8. Control of campylobacter in poultry industry from farm to poultry processing unit: A review.

    PubMed

    Umaraw, Pramila; Prajapati, A; Verma, Akhilesh K; Pathak, V; Singh, V P

    2017-03-04

    Campylobacter is an emerging zoonotic bacterial threat in the poultry industry. Most of the human cases of campylobacteriosis recorded have revealed their poultry origins. Various control measures have been employed both at the farm and processing levels to combat with it. The antibiotic treatment, phage therapy, competitive exclusion, and vaccination have been adapted at the farm level to reduce colonization of Campylobacter in poultry gut. While prevention of intestinal spillage, scheduled slaughter, logistic slaughter, chemical decontamination of carcasses are recommended to reduce contamination during processing. The postharvest interventions such as heat treatment, freezing, irradiation of contaminated carcass can effectively reduce Campylobacter contamination. Thus, integrated approaches are required to tackle infection of Campylobacter in humans.

  9. Contamination in fractured-rock aquifers: Research at the former Naval Air Warfare Center, West Trenton, New Jersey

    USGS Publications Warehouse

    Goode, Daniel J.; Tiedeman, Claire; Lacombe, Pierre J.; Imbrigiotta, Thomas E.; Shapiro, Allen M.; Chapelle, Francis H.

    2007-01-01

    The U.S. Geological Survey and cooperators are studying chlorinated solvents in a fractured sedimentary rock aquifer underlying the former Naval Air Warfare Center (NAWC), West Trenton, New Jersey. Fractured-rock aquifers are common in many parts of the United States and are highly susceptible to contamination, particularly at industrial sites. Compared to 'unconsolidated' aquifers, there can be much more uncertainty about the direction and rate of contaminant migration and about the processes and factors that control chemical and microbial transformations of contaminants. Research at the NAWC is improving understanding of the transport and fate of chlorinated solvents in fractured-rock aquifers and will compare the effectiveness of different strategies for contaminant remediation.

  10. Ground-water flow in the Prairie du Chien-Jordan aquifer related to contamination by coal-tar derivatives, St. Louis Park, Minnesota

    USGS Publications Warehouse

    Stark, J.R.; Hult, M.F.

    1985-01-01

    Simulation of a proposed gradient-control plan, in which lateral homogeneity and isotropy of individual hydro geologic units was assumed, indicates that the actions would be effective in limiting expansion of the contaminated volume in the Prairie du Chien-Jordan aquifer. The plan includes the control of withdrawal from five wells. The simulations also show, however, that modelcalculated potentiometric surfaces are sensitive to changes in withdrawal rates at wells not intended to be under the control of the plan. Management of discharge from these wells also will be important to overall effectiveness of the remedial-action plan.

  11. Disinfectants used for environmental disinfection and new room decontamination technology.

    PubMed

    Rutala, William A; Weber, David J

    2013-05-01

    Environmental contamination plays an important role in the transmission of several key health care-associated pathogens. Effective and thorough cleaning/disinfecting of the patient environment is essential. Room decontamination units (such as ultraviolet-C and hydrogen peroxide systems) aid in reducing environmental contamination after terminal room cleaning and disinfection. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  12. Results of the Particulate Contamination Control Trade Study for Space Suit Life Support Development

    NASA Technical Reports Server (NTRS)

    Cognata, Thomas J.; Conger, Bruce; Paul, Heather L.

    2009-01-01

    As the United States plans to return astronauts to the moon and eventually to Mars, designing the most effective, efficient, and robust space suit life support system that will operate successfully in these dusty environments is vital. There is some knowledge of the contaminants and level of infiltration expected from the Lunar and Mars dust, however risk mitigation strategies and filtration designs to prevent contamination within the space suit life support system are still undefined. A trade study was initiated to identify and address these concerns, and to develop new requirements for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS). This trade study investigates historical methods of particulate contamination control in space suits and vehicles, and evaluated the possibility of using commercial technologies for this application. In addition, the trade study examined potential filtration designs. This paper summarizes the results of this trade study.

  13. Results of the Trace Contaminant Control Trade Study for Space Suit Life Support Development

    NASA Technical Reports Server (NTRS)

    Jennings, Mallory A.; Paul, Heather L.

    2008-01-01

    As the United States plans to return astronauts to the moon, designing the most effective and efficient life support systems is of extreme importance. The trace contaminant control system (TCCS) will be located within the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), and is responsible for removing contaminants, which at increased levels can be hazardous to a crewmember s health. These contaminants come from several sources including metabolic production of the crewmember (breathing, sweating, etc.) and offgassing of the space suit material layers. This paper summarizes the results of a trade study that investigated TCC technologies used in NASA space suits and vehicles as well as commercial and academic applications, to identify the best technology options for the CSSE PLSS. The trade study also looked at the feasibility of regeneration of TCC technologies, specifically to determine the viability of vacuum regeneration for on-back, realtime EVA.

  14. Results of the Trace Contaminant Control Trade Study for Space Suit Life Support Development

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.; Jennings, Mallory A.

    2009-01-01

    As the United States plans to return astronauts to the moon, designing the most effective and efficient life support systems is of extreme importance. The trace contaminant control system (TCCS) will be located within the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), and is responsible for removing contaminants, which at increased levels can be hazardous to a crewmember's health. These contaminants come from several sources including metabolic production of the crewmember (breathing, sweating, etc.) and offgassing of the space suit material layers. This paper summarizes the results of a trade study that investigated TCC technologies used in NASA space suits and vehicles as well as commercial and academic applications, to identify the best technology options for the CSSE PLSS. The trade study also looked at the feasibility of regeneration of TCC technologies, specifically to determine the viability of vacuum regeneration for on-back, real-time EVA.

  15. Method for removing metal vapor from gas streams

    DOEpatents

    Ahluwalia, R.K.; Im, K.H.

    1996-04-02

    A process for cleaning an inert gas contaminated with a metallic vapor, such as cadmium, involves withdrawing gas containing the metallic contaminant from a gas atmosphere of high purity argon; passing the gas containing the metallic contaminant to a mass transfer unit having a plurality of hot gas channels separated by a plurality of coolant gas channels; cooling the contaminated gas as it flows upward through the mass transfer unit to cause contaminated gas vapor to condense on the gas channel walls; regenerating the gas channels of the mass transfer unit; and, returning the cleaned gas to the gas atmosphere of high purity argon. The condensing of the contaminant-containing vapor occurs while suppressing contaminant particulate formation, and is promoted by providing a sufficient amount of surface area in the mass transfer unit to cause the vapor to condense and relieve supersaturation buildup such that contaminant particulates are not formed. Condensation of the contaminant is prevented on supply and return lines in which the contaminant containing gas is withdrawn and returned from and to the electrorefiner and mass transfer unit by heating and insulating the supply and return lines. 13 figs.

  16. Method for removing metal vapor from gas streams

    DOEpatents

    Ahluwalia, R. K.; Im, K. H.

    1996-01-01

    A process for cleaning an inert gas contaminated with a metallic vapor, such as cadmium, involves withdrawing gas containing the metallic contaminant from a gas atmosphere of high purity argon; passing the gas containing the metallic contaminant to a mass transfer unit having a plurality of hot gas channels separated by a plurality of coolant gas channels; cooling the contaminated gas as it flows upward through the mass transfer unit to cause contaminated gas vapor to condense on the gas channel walls; regenerating the gas channels of the mass transfer unit; and, returning the cleaned gas to the gas atmosphere of high purity argon. The condensing of the contaminant-containing vapor occurs while suppressing contaminant particulate formation, and is promoted by providing a sufficient amount of surface area in the mass transfer unit to cause the vapor to condense and relieve supersaturation buildup such that contaminant particulates are not formed. Condensation of the contaminant is prevented on supply and return lines in which the contaminant containing gas is withdrawn and returned from and to the electrorefiner and mass transfer unit by heating and insulating the supply and return lines.

  17. Assessing occupational exposure to sea lamprey pesticides

    PubMed Central

    Ceballos, Diana M; Beaucham, Catherine C; Kurtz, Kristine; Musolin, Kristin

    2015-01-01

    Background: Sea lampreys are parasitic fish found in lakes of the United States and Canada. Sea lamprey is controlled through manual application of the pesticides 3-trifluoromethyl-4-nitrophenol (TFM) and BayluscideTM into streams and tributaries. 3-Trifluoromethyl-4-nitrophenol may cause irritation and central nervous system depression and Bayluscide may cause irritation, dermatitis, blisters, cracking, edema, and allergic skin reactions. Objectives: To assess occupational exposures to sea lamprey pesticides. Methods: We developed a wipe method for evaluating surface and skin contamination with these pesticides. This method was field tested at a biological field station and at a pesticide river application. We also evaluated exposures using control banding tools. Results: We verified TFM surface contamination at the biological station. At the river application, we found surfaces and worker’s skin contaminated with pesticides. Conclusion: We recommended minimizing exposures by implementing engineering controls and improved use of personal protective equipment. PMID:25730600

  18. Tooele Army Depot - North Area. Feasibility Study for Operable Units 5, 6, 7, and 10

    DTIC Science & Technology

    1994-03-01

    effectiveness of alternatives in maintaining protection of human health and the environment after response objectives have been met. 4. Reduction of toxicity...Institutional controls may be effective at protecting human health and the environment and complying with ARARs if the site contaminants have low toxicity...reduction of the toxicity, mobility, or volume of soil contaminants through treatment under this alternative. Short-term effectiveness . Human health

  19. Supplemental treatment of air in airborne infection isolation rooms using high-throughput in-room air decontamination units.

    PubMed

    Bergeron, Vance; Chalfine, Annie; Misset, Benoît; Moules, Vincent; Laudinet, Nicolas; Carlet, Jean; Lina, Bruno

    2011-05-01

    Evidence has recently emerged indicating that in addition to large airborne droplets, fine aerosol particles can be an important mode of influenza transmission that may have been hitherto underestimated. Furthermore, recent performance studies evaluating airborne infection isolation (AII) rooms designed to house infectious patients have revealed major discrepancies between what is prescribed and what is actually measured. We conducted an experimental study to investigate the use of high-throughput in-room air decontamination units for supplemental protection against airborne contamination in areas that host infectious patients. The study included both intrinsic performance tests of the air-decontamination unit against biological aerosols of particular epidemiologic interest and field tests in a hospital AII room under different ventilation scenarios. The unit tested efficiently eradicated airborne H5N2 influenza and Mycobacterium bovis (a 4- to 5-log single-pass reduction) and, when implemented with a room extractor, reduced the peak contamination levels by a factor of 5, with decontamination rates at least 33% faster than those achieved with the extractor alone. High-throughput in-room air treatment units can provide supplemental control of airborne pathogen levels in patient isolation rooms. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  20. Mycological contamination in dental unit waterlines in Istanbul, Turkey

    PubMed Central

    Kadaifciler, Duygu Göksay; Ökten, Suzan; Sen, Burhan

    2013-01-01

    Studies on dental units (DUs) are conducted either for the prevention or the reduction of the density of bacterial contamination in dental unit waterlines (DUWLs). However, the existence of fungi in the these systems requires more attention. During dental treatment, direct contact with water contaminated with fungi such as Candida, Aspergillus, or inhalation of aerosols from high-speed drill may cause various respiratory infections, such as asthma, allergies, and wounds on mucose membranes, especially on immunocompromised patients and dentists. The aims of this study are to investigate the number and colonization of fungi in DUWLs in the city of Istanbul, Turkey. Water samples were collected from air-water syringes, high-speed drills, and inlet waters from 41 DUs. The aerobic mesophilic fungi count in high- speed drills was higher than inlet waters and air-water syringes. Non-sporulating fungi were found in 7 DUs. The isolated fungi were identified as Penicillium waksmanii, Cladosporium spp., Penicillium spp., Candida famata, Cryptococcus laurentii, Candida guilliermondii, Penicillium verrucosum, Aspergillus pseudoglaucus, Penicillium decumbens, and Acremonium sp. Some of these fungal genera are known as opportunistic pathogens that led to respiratory diseases such as allergic rhinits. This study shows the importance of regular control of mycological contamination on water at DUs. PMID:24516467

  1. Effect of various infection-control methods for light-cure units on the cure of composite resins.

    PubMed

    Chong, S L; Lam, Y K; Lee, F K; Ramalingam, L; Yeo, A C; Lim, C C

    1998-01-01

    This study (1) compared the curing-light intensity with various barrier infection-control methods used to prevent cross contamination, (2) compared the Knoop hardness value of cured composite resin when various barrier control methods were used, and (3) correlated the hardness of the composite resin with the light-intensity output when different infection-control methods were used. The light-cure unit tips were covered with barriers, such as cellophane wrap, plastic gloves, Steri-shields, and finger cots. The control group had no barrier. Composite resins were then cured for each of the five groups, and their Knoop hardness values recorded. The results showed that there was significant statistical difference in the light-intensity output among the five groups. However, there was no significant statistical difference in the Knoop hardness values among any of the groups. There was also no correlation between the Knoop hardness value of the composite resin with the light-intensity output and the different infection-control methods. Therefore, any of the five infection-control methods could be used as barriers for preventing cross-contamination of the light-cure unit tip, for the light-intensity output for all five groups exceeded the recommended value of 300 W/m2. However, to allow a greater margin of error in clinical situations, the authors recommend that the plastic glove or the cellophane wrap be used to wrap the light-cure tip, since these barriers allowed the highest light-intensity output.

  2. Groundwater Flow Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greg Ruskauff

    2006-06-01

    The Pahute Mesa groundwater flow model supports the FFACO UGTA corrective action strategy objective of providing an estimate of the vertical and horizontal extent of contaminant migration for each CAU in order to predict contaminant boundaries. A contaminant boundary is the model-predicted perimeter that defines the extent of radionuclide-contaminated groundwater from underground nuclear testing above background conditions exceeding Safe Drinking Water Act (SDWA) standards. The contaminant boundary will be composed of both a perimeter boundary and a lower hydrostratigraphic unit (HSU) boundary. Additional results showing contaminant concentrations and the location of the contaminant boundary at selected times will also bemore » presented. These times may include the verification period, the end of the five-year proof-of-concept period, as well as other times that are of specific interest. The FFACO (1996) requires that the contaminant transport model predict the contaminant boundary at 1,000 years and “at a 95% level of confidence.” The Pahute Mesa Phase I flow model described in this report provides, through the flow fields derived from alternative hydrostratigraphic framework models (HFMs) and recharge models, one part of the data required to compute the contaminant boundary. Other components include the simplified source term model, which incorporates uncertainty and variability in the factors that control radionuclide release from an underground nuclear test (SNJV, 2004a), and the transport model with the concomitant parameter uncertainty as described in Shaw (2003). The uncertainty in all the above model components will be evaluated to produce the final contaminant boundary. This report documents the development of the groundwater flow model for the Central and Western Pahute Mesa CAUs.« less

  3. Hantavirus infection--southwestern United States: interim recommendations for risk reduction. Centers for Disease Control and Prevention.

    PubMed

    Childs, J E; Kaufmann, A F; Peters, C J; Ehrenberg, R L

    1993-07-30

    This report provides interim recommendations for prevention and control of hantavirus infections associated with rodents in the southwestern United States. It is based on principles of rodent and infection control and contains specific recommendations for reducing rodent shelter and food sources in and around the home, recommendations for eliminating rodents inside the home and preventing them from entering the home, precautions for preventing hantavirus infection while rodent-contaminated areas are being cleaned up, prevention measures for persons who have occupational exposure to wild rodents, and precautions for campers and hikers.

  4. Effectiveness of a Closed-System Transfer Device in Reducing Surface Contamination in a New Antineoplastic Drug-Compounding Unit: A Prospective, Controlled, Parallel Study

    PubMed Central

    Pinturaud, Marine; Soichot, Marion; Richeval, Camille; Humbert, Luc; Lebecque, Michèle; Sidikou, Ousseini; Barthelemy, Christine; Bonnabry, Pascal; Allorge, Delphine; Décaudin, Bertrand; Odou, Pascal

    2016-01-01

    Background The objective of this randomized, prospective and controlled study was to investigate the ability of a closed-system transfer device (CSTD; BD-Phaseal) to reduce the occupational exposure of two isolators to 10 cytotoxic drugs and compare to standard compounding devices. Methods and Findings The 6-month study started with the opening of a new compounding unit. Two isolators were set up with 2 workstations each, one to compound with standard devices (needles and spikes) and the other using the Phaseal system. Drugs were alternatively compounded in each isolator. Sampling involved wiping three surfaces (gloves, window, worktop), before and after a cleaning process. Exposure to ten antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-FU, methotrexate, gemcitabine, cytarabine, irinotecan, doxorubicine and ganciclovir) was assessed on wipes by LC-MS/MS analysis. Contamination rates were compared using a Chi2 test and drug amounts by a Mann-Whitney test. Significance was defined for p<0.05. Overall contamination was lower in the “Phaseal” isolator than in the “Standard” isolator (12.24% vs. 26.39%; p < 0.0001) although it differed according to drug. Indeed, the contamination rates of gemcitabine were 49.3 and 43.4% (NS) for the Standard and Phaseal isolators, respectively, whereas for ganciclovir, they were 54.2 and 2.8% (p<0.0001). Gemcitabine amounts were 220.6 and 283.6 ng for the Standard and Phaseal isolators (NS), and ganciclovir amounts were 179.9 and 2.4 ng (p<0.0001). Conclusion This study confirms that using a CSTD may significantly decrease the chemical contamination of barrier isolators compared to standard devices for some drugs, although it does not eliminate contamination totally. PMID:27391697

  5. Natural Remediation at Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, C. M.; Van Pelt, R.

    2002-02-25

    Natural remediation is a general term that includes any technology or strategy that takes advantage of natural processes to remediate a contaminated media to a condition that is protective of human health and the environment. Natural remediation techniques are often passive and minimally disruptive to the environment. They are generally implemented in conjunction with traditional remedial solutions for source control (i.e., capping, stabilization, removal, soil vapor extraction, etc.). Natural remediation techniques being employed at Savannah River Site (SRS) include enhanced bio-remediation, monitored natural attenuation, and phytoremediation. Enhanced bio-remediation involves making nutrients available and conditions favorable for microbial growth. With propermore » precautions and feeding, the naturally existing microbes flourish and consume the contaminants. Case studies of enhanced bio-remediation include surface soils contaminated with PCBs and pesticides, and Volatile Organic Compound (VOC) contamination in both the vadose zone and groundwater. Monitored natural attenuation (MNA) has been selected as the preferred alternative for groundwater clean up at several SRS waste units. Successful implementation of MNA has been based on demonstration that sources have been controlled, groundwater modeling that indicates that plumes will not expand or reach surface water discharge points at levels that exceed regulatory limits, and continued monitoring. Phytoremediation is being successfully utilized at several SRS waste units. Phytoremediation involves using plants and vegetation to uptake, break down, or manage contaminants in groundwater or soils. Case studies at SRS include managing groundwater plumes of tritium and VOCs with pine trees that are native to the area. Significant decreases in tritium discharge to a site stream have been realized in one phytoremediation project. Studies of other vegetation types, methods of application, and other target contaminants are underway.« less

  6. An evaluation of the infection control potential of a UV clinical podiatry unit.

    PubMed

    Humphreys, Paul N; Davies, Chris S; Rout, Simon

    2014-02-28

    Infection control is a key issue in podiatry as it is in all forms of clinical practice. Airborne contamination may be particularly important in podiatry due to the generation of particulates during treatment. Consequently, technologies that prevent contamination in podiatry settings may have a useful role. The aims of this investigation were twofold, firstly to determine the ability of a UV cabinet to protect instruments from airborne contamination and secondly to determine its ability to remove microbes from contaminated surfaces and instruments. A UV instrument cabinet was installed in a University podiatry suite. Impact samplers and standard microbiological techniques were used to determine the nature and extent of microbial airborne contamination. Sterile filters were used to determine the ability of the UV cabinet to protect exposed surfaces. Artificially contaminated instruments were used to determine the ability of the cabinet to remove microbial contamination. Airborne bacterial contamination was dominated by Gram positive cocci including Staphylococcus aureus. Airborne fungal levels were much lower than those observed for bacteria. The UV cabinet significantly reduced (p < 0.05) the observed levels of airborne contamination. When challenged with contaminated instruments the cabinet was able to reduce microbial levels by between 60% to 100% with more complex instruments e.g. clippers, remaining contaminated. Bacterial airborne contamination is a potential infection risk in podiatry settings due to the presence of S. aureus. The use of a UV instrument cabinet can reduce the risk of contamination by airborne microbes. The UV cabinet tested was unable to decontaminate instruments and as such could pose an infection risk if misused.

  7. An evaluation of the infection control potential of a UV clinical podiatry unit

    PubMed Central

    2014-01-01

    Background Infection control is a key issue in podiatry as it is in all forms of clinical practice. Airborne contamination may be particularly important in podiatry due to the generation of particulates during treatment. Consequently, technologies that prevent contamination in podiatry settings may have a useful role. The aims of this investigation were twofold, firstly to determine the ability of a UV cabinet to protect instruments from airborne contamination and secondly to determine its ability to remove microbes from contaminated surfaces and instruments. Method A UV instrument cabinet was installed in a University podiatry suite. Impact samplers and standard microbiological techniques were used to determine the nature and extent of microbial airborne contamination. Sterile filters were used to determine the ability of the UV cabinet to protect exposed surfaces. Artificially contaminated instruments were used to determine the ability of the cabinet to remove microbial contamination. Results Airborne bacterial contamination was dominated by Gram positive cocci including Staphylococcus aureus. Airborne fungal levels were much lower than those observed for bacteria. The UV cabinet significantly reduced (p < 0.05) the observed levels of airborne contamination. When challenged with contaminated instruments the cabinet was able to reduce microbial levels by between 60% to 100% with more complex instruments e.g. clippers, remaining contaminated. Conclusions Bacterial airborne contamination is a potential infection risk in podiatry settings due to the presence of S. aureus. The use of a UV instrument cabinet can reduce the risk of contamination by airborne microbes. The UV cabinet tested was unable to decontaminate instruments and as such could pose an infection risk if misused. PMID:24576315

  8. United States Air Force Graduate Student Research Program. 1989 Program Technical Report. Volume 2

    DTIC Science & Technology

    1989-12-01

    Patterson Air Force Base) 1. Fred Arnold 4. Jon Longtin 2. Duane Daddis 5. John McCord 3. Robert Gabruk 6. Scott VanDam ARMAMENT LABORATORY (ATL) ( Eglin Air...Report as Dr. Beryl Barber *** Engineering and Services Center 22 Effects of Jet Aircraft Noise on Jon Zern Domestic Goats 23 Contaminant Flux...Pertaining to Ground Water Contamination and Laboratory Quality Control *** Same Report as Dr. Barbara Alvin * School of Aerospace Medicine 93

  9. A Model to Guide Development of Environmental Final Governing Standards for Overseas United States Department of Defense Installations

    DTIC Science & Technology

    2014-03-28

    four sub-sections were included into “System” because none of them address limits of contaminates or chemicals in the water. 24 The Hazardous...maximum contaminant levels (MCL) of chemicals, stricter emission standards, stricter control limits, greater minimum separation distances, prohibited...0.37 Indonesia Strugglers 52.29 -0.40 Malaysia Progressives 62.51 0.34 Mongolia Regressives 45.37 -0.21 Myanmar Strugglers 52.72 -1.09 Nepal

  10. Plant growth chamber based on space proven controlled environment technology

    NASA Astrophysics Data System (ADS)

    Ignatius, Ronald W.; Ignatius, Matt H.; Imberti, Henry J.

    1997-01-01

    Quantum Devices, Inc., in conjunction with Percival Scientific, Inc., and the Wisconsin Center for Space Automation and Robotics (WCSAR) have developed a controlled environment plant growth chamber for terrestrial agricultural and scientific applications. This chamber incorporates controlled environment technology used in the WCSAR ASTROCULTURE™ flight unit for conducting plant research on the Space Shuttle. The new chamber, termed CERES 2010, features air humidity, temperature, and carbon dioxide control, an atmospheric contaminant removal unit, an LED lighting system, and a water and nutrient delivery system. The advanced environment control technology used in this chamber will increase the reliability and repeatability of environmental physiology data derived from plant experiments conducted in this chamber.

  11. Effects of natural and human factors on groundwater quality of basin-fill aquifers in the southwestern United States-conceptual models for selected contaminants

    USGS Publications Warehouse

    Bexfield, Laura M.; Thiros, Susan A.; Anning, David W.; Huntington, Jena M.; McKinney, Tim S.

    2011-01-01

    As part of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program, the Southwest Principal Aquifers (SWPA) study is building a better understanding of the factors that affect water quality in basin-fill aquifers in the Southwestern United States. The SWPA study area includes four principal aquifers of the United States: the Basin and Range basin-fill aquifers in California, Nevada, Utah, and Arizona; the Rio Grande aquifer system in New Mexico and Colorado; and the California Coastal Basin and Central Valley aquifer systems in California. Similarities in the hydrogeology, land- and water-use practices, and water-quality issues for alluvial basins within the study area allow for regional analysis through synthesis of the baseline knowledge of groundwater-quality conditions in basins previously studied by the NAWQA Program. Resulting improvements in the understanding of the sources, movement, and fate of contaminants are assisting in the development of tools used to assess aquifer susceptibility and vulnerability.This report synthesizes previously published information about the groundwater systems and water quality of 15 information-rich basin-fill aquifers (SWPA case-study basins) into conceptual models of the primary natural and human factors commonly affecting groundwater quality with respect to selected contaminants, thereby helping to build a regional understanding of the susceptibility and vulnerability of basin-fill aquifers to those contaminants. Four relatively common contaminants (dissolved solids, nitrate, arsenic, and uranium) and two contaminant classes (volatile organic compounds (VOCs) and pesticide compounds) were investigated for sources and controls affecting their occurrence and distribution above specified levels of concern in groundwater of the case-study basins. Conceptual models of factors that are important to aquifer vulnerability with respect to those contaminants and contaminant classes were subsequently formed. The conceptual models are intended in part to provide a foundation for subsequent development of regional-scale statistical models that relate specific constituent concentrations or occurrence in groundwater to natural and human factors.

  12. Control of natural microorganisms in chamomile (Chamomilla recutita L.) by gamma ray and electron beam irradiation.

    PubMed

    Al-Bachir, Mahfouz

    2017-01-01

    Microbial contamination levels and corresponding sensitivities to gamma rays (GR) and elec- tron beam (EB) irradiation were tested in chamomile (Chamomile recutta L.). Chamomile powders were treated with 10 and 20 kGy by GR and EB, respectively. Microbiological and chemical analyses were performed on controls and treated samples immediately after irradiation, and after 12 months of storage. The control samples of chamomile exhibited rather high microbiological contamination, exceeding the levels of 4 log10 CFU g-1   (CFU - colony forming units) reported by national and international authorities as the maximum permissible total count level. Irradiation with GR and EB was found to cause a reduction in microbial contamination proportionate to the dose delivered. The sterilizing effect of EB on microorganisms was higher than the GR one. A dose of 10 kGy of GR and EB significantly (p < 0.05) reduced the total bacte- rial, total coliform and total fungal contamination. A dose of 20 kGy of GR significantly (p < 0.05) reduced the total bacterial and total fungal contamination, while a 20 kGy dose of EB reduced the initial bacterial, total coliform and total fungal contamination to below detection level when the analysis was carried out im- mediately after irradiation treatment or after 12 months of storage. The comparative study demonstrated that electron beam was more effective for decontamination of chamomile powder than gamma irradiation.

  13. Conventional and nonconventional strategies for controlling bacterial contamination in fuel ethanol fermentations.

    PubMed

    Ceccato-Antonini, Sandra Regina

    2018-05-25

    Ethanol bio-production in Brazil has some unique characteristics that inevitably lead to bacterial contamination, which results in the production of organic acids and biofilms and flocculation that impair the fermentation yield by affecting yeast viability and diverting sugars to metabolites other than ethanol. The ethanol-producing units commonly give an acid treatment to the cells after each fermentative cycle to decrease the bacterial number, which is not always effective. An alternative strategy must be employed to avoid bacterial multiplication but must be compatible with economic, health and environmental aspects. This review analyzes the issue of bacterial contamination in sugarcane-based fuel ethanol fermentation, and the potential strategies that may be utilized to control bacterial growth besides acid treatment and antibiotics. We have emphasized the efficiency and suitability of chemical products other than acids and those derived from natural sources in industrial conditions. In addition, we have also presented bacteriocins, bacteriophages, and beneficial bacteria as non-conventional antimicrobial agents to mitigate bacterial contamination in the bioethanol industry.

  14. Flow monitoring and control system for injection wells

    DOEpatents

    Corey, J.C.

    1991-01-01

    The present invention relates to a system for monitoring and controlling the rate of fluid flow from an injection well used for in-situ remediation of contaminated groundwater. The United States Government has rights in this invention pursuant to Contract No. DE-AC09-89SR18035 between the US Department of Energy and Westinghouse Savannah River Company.

  15. Urban wet-weather flows: sources of fecal contamination impacting on recreational waters and threatening drinking-water sources.

    PubMed

    Marsalek, Jiri; Rochfort, Quintin

    Discharges of urban stormwater and combined sewer overflows (CSOs) contribute to fecal contamination of urban waters and need to be considered in planning the protection of recreational waters and sources of drinking water. Stormwater characterization indicates that Escherichia coli counts in stormwater typically range from 103 to 104 units per 100 ml. Higher counts (10(5) units/100 ml) suggest the presence of cross-connections with sanitary sewers, and such connections should be identified and corrected. Fecal contamination of stormwater may be attenuated prior to discharge into surface waters by stormwater management measures, which typically remove suspended solids and attached bacteria. Exceptionally, stormwater discharges in the vicinity of swimming beaches are disinfected. The levels of indicator bacteria in CSOs can be as high as 10(6) E. coli per 100 ml. Consequently, the abatement of fecal contamination of CSOs is now considered in the design of CSO control and treatment, as for example stipulated in the Ontario Procedure F-5-5. CSO abatement options comprise combin ations of storage and treatment, in which the CSO treatment generally includes disinfection by ultraviolet (UV) irradiation. Finally, indicator bacteria data from Sarnia (Ontario) were used to demonstrate some fecal contamination impacts of wet-weather flows. In wet weather, the microbiological quality of riverine water worsened as a result of CSO and stormwater discharges, and the recreational water guidelines for indicator organisms were exceeded most of the time. Local improvements in water quality were feasible by source controls and diversion of polluted water.

  16. Operational level for unconditional release of contaminated property from affected areas around Fukushima Daiichi nuclear power plant

    PubMed Central

    Ogino, Haruyuki; Hattori, Takatoshi

    2013-01-01

    This paper focuses on the surface contamination control of slightly contaminated property after the Fukushima nuclear accident. The operational level for the unconditional release of contaminated properties is calculated in counts per minute (cpm) to enable the use of a typical Geiger-Muller (GM) survey meter with a 50-mm bore, on the basis of the surficial clearance level of 10 Bq cm−2 for 134Cs and 137Cs derived in the previous studies of the authors. By applying a factor for the conversion of the unit surface contamination to the count rate of a survey meter widely used after the Fukushima accident, the operational level for the unconditional release of contaminated properties was calculated to be 2300 cpm on average and 23 000 cpm at the highest-contamination part. The calculated numerical values of the operational levels are effective as long as the typical GM survey meter is used in the radiation measurement. PMID:23778575

  17. Occurrence and diversity of both bacterial and fungal communities in dental unit waterlines subjected to disinfectants.

    PubMed

    Costa, Damien; Mercier, Anne; Gravouil, Kevin; Lesobre, Jérôme; Verdon, Julien; Imbert, Christine

    2016-10-01

    Chemical disinfectants are widely advocated to reduce the microbial contamination in dental unit waterlines (DUWL). However, until now their efficacy has been poorly examined after long-term application. In this study, through quantitative PCR and high-throughput sequencing, both bacterial and fungal communities were profiled from 8- to 12-year-old DUWL treated with disinfectants commonly used by European dentists. Water was collected from the tap water supplying units to the output exposure point of the turbine handpiece following a stagnation period and dental care activity. Results showed that (i) the unit itself is the principal source of microbial contamination and (ii) water stagnation, DU maintenance practices and quality of water supplying DU appeared as parameters driving the water quality. Despite disinfecting treatment combined to flushing process, the microbial contamination remained relevant in the studied output water, in association with a high bacterial and fungal diversity. The occurrence of potentially pathogenic microorganisms in these treated DUWL demonstrated a potential infectious risk for both patients and dental staff. A disinfectant shock before a prolonged stagnation period could limit the microbial proliferation inside DUWL. Necessity to proceed to regular water quality control of DUWL was highlighted. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Development and testing of a contamination potential mapping system for a portion of the General Separations Area, Savannah River Site, South Carolina

    USGS Publications Warehouse

    Rine, J.M.; Berg, R.C.; Shafer, J.M.; Covington, E.R.; Reed, J.K.; Bennett, C.B.; Trudnak, J.E.

    1998-01-01

    A methodology was developed to evaluate and map the contamination potential or aquifer sensitivity of the upper groundwater flow system of a portion of the General Separations Area (GSA) at the Department of Energy's Savannah River Site (SRS) in South Carolina. A Geographic Information System (GIS) was used to integrate diverse subsurface geologic data, soils data, and hydrology utilizing a stack-unit mapping approach to construct mapping layers. This is the first time that such an approach has been used to delineate the hydrogeology of a coastal plain environment. Unit surface elevation maps were constructed for the tops of six Tertiary units derived from over 200 boring logs. Thickness or isopach maps were created for five hydrogeologic units by differencing top and basal surface elevations. The geologic stack-unit map was created by stacking the five isopach maps and adding codes for each stack-unit polygon. Stacked-units were rated according to their hydrogeologic properties and ranked using a logarithmic approach (utility theory) to establish a contamination potential index. Colors were assigned to help display relative importance of stacked-units in preventing or promoting transport of contaminants. The sensitivity assessment included the effects of surface soils on contaminants which are particularly important for evaluating potential effects from surface spills. Hydrogeologic/hydrologic factors did not exhibit sufficient spatial variation to warrant incorporation into contamination potential assessment. Development of this contamination potential mapping system provides a useful tool for site planners, environmental scientists, and regulatory agencies.A methodology was developed to evaluate and map the contamination potential or aquifer sensitivity of the upper groundwater flow system of a portion of the General Separations Area (GSA) at the Department of Energy's Savannah River Site (SRS) in South Carolina. A Geographic Information System (GIS) was used to integrate diverse subsurface geologic data, soils data, and hydrology utilizing a stack-unit mapping approach to construct mapping layers. This is the first time that such an approach has been used to delineate the hydrogeology of a coastal plain environment. Unit surface elevation maps were constructed for the tops of six Tertiary units derived from over 200 boring logs. Thickness or isopach maps were created for five hydrogeologic units by differencing top and basal surface elevations. The geologic stack-unit map was created by stacking the five isopach maps and adding codes for each stack-unit polygon. Stacked-units were rated according to their hydrogeologic properties and ranked using a logarithmic approach (utility theory) to establish a contamination potential index. Colors were assigned to help display relative importance of stacked-units in preventing or promoting transport of contaminants. The sensitivity assessment included the effects of surface soils on contaminants which are particularly important for evaluating potential effects from surface spills. Hydrogeologic/hydrologic factors did not exhibit sufficient spatial variation to warrant incorporation into contamination potential assessment. Development of this contamination potential mapping system provides a useful tool for site planners, environmental scientists, and regulatory agencies.

  19. The use of poultry litter as co-substrate and source of inorganic nutrients and microorganisms for the ex situ biodegradation of petroleum compounds.

    PubMed

    Williams, C M; Grimes, J L; Mikkelsen, R L

    1999-07-01

    The purpose of this investigation was to determine the feasibility of utilizing poultry litter as a source of microorganisms, C co-substrate, N, and P to enhance the biodegradation of petroleum compounds in contaminated soil. An initial laboratory-scale study utilized soil contaminated with approximately 3,000 mg/kg (ppm) total petroleum hydrocarbons (TPHC) as diesel fuel. Biotreatment units, each containing 10 L of contaminated soil, were supplemented (0, 1, 10, and 20%, total weight basis) with broiler litter containing 3.65% N and 1.89% P. Petroleum-degrading microorganisms previously enriched from broiler and turkey litter were also inoculated into the litter-treated units. A significant first order rate of TPHC biodegradation was measured for all treatment units containing broiler litter (P < 0.05). Based on these results, a subsequent study was conducted at the site of a commercial facility permitted to treat soil (ex situ) contaminated with hazardous compounds. Soil treatment plots, each containing approximately 1 ton of soil contaminated with approximately 1,200 to 1,600 mg/kg diesel fuel were established. Each plot was replicated four times and the experiment was conducted for 35 d. Treatments were as follows: control, soil only; soil + commercial blend of bioremediation nutrients; soil + commercial fertilizer; soil + poultry litter (1% by volume); soil + poultry litter (10% by volume); soil + pelleted poultry litter (10% by volume). The results showed that the remediation of soil contaminated with petroleum compounds is significantly (P < 0.05) enhanced when supplemented with poultry litter (pelleted or nonpelleted) in concentrations of 10% soil volume. These results demonstrate the potential for a specialized market for the use of poultry litter.

  20. A multi-disciplinary approach to the removal of emerging contaminants in municipal wastewater treatment plants in New York state (2003-2004)

    USGS Publications Warehouse

    Philips, Patrick J.; Stinson, Beverley; Zaugg, Steven D.; Furlong, Edward T.; Kolpin, Dana W.; Esposito, Kathleen; Bodniewicz, B.; Pape, R.; Anderson, J.

    2008-01-01

    Across the United States, there is a rapidly growing awareness of the occurrence and the toxicological impacts of natural and synthetic trace compounds in the environment. These trace compounds, referred to as emerging contaminants (ECs), are reported to cause a range of negative impacts in the environment, such as adverse effects on biota in receiving streams and interference with the normal functions of the endocrine system, which controls growth and development in living organisms.

  1. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 528: POLYCHLORINATED BIPHENYLS CONTAMINATION NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BECHTEL NEVADA

    2006-09-01

    This Closure Report (CR) describes the closure activities performed at CAU 528, Polychlorinated Biphenyls Contamination, as presented in the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) (US. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSAINSO], 2005). The approved closure alternative was closure in place with administrative controls. This CR provides a summary of the completed closure activities, documentation of waste disposal, and analytical data to confirm that the remediation goals were met.

  2. Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

    PubMed

    Ji, Xue-Yue; Fei, Chun-Nan; Zhang, Ying; Zhang, Wei; Liu, Jun; Dong, Jie

    2016-08-01

    Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment. © 2016 FDI World Dental Federation.

  3. Effects of feeding diets naturally contaminated with Fusarium mycotoxins on protein metabolism in late gestation and lactation of first-parity sows.

    PubMed

    Díaz-Llano, G; Smith, T K; Boermans, H J; Caballero-Cortes, C; Friendship, R

    2010-03-01

    A study was conducted to assess the effects of feeding a blend of grains naturally contaminated with Fusarium mycotoxins to sows on the capacity for protein synthesis in skeletal muscle, the protein content per cellular unit, and the efficacy of a polymeric glucomannan adsorbent (GMA) to prevent these effects in late gestation and in lactation. Thirty-two Yorkshire sows were assigned to 4 treatment groups (8 per treatment) from 91 +/- 3 d of gestation up to weaning on d 21 after farrowing. Diets included 1) control, 2) contaminated grains, and 3) contaminated grains + 0.2% GMA. A fourth treatment of feeding sows the control diet at a restricted feed allowance was also included. The variables measured include ADFI, average daily BW change, serum total protein, urea, and ammonia, and skeletal muscle DNA, RNA, and protein. To assess the capacity for protein synthesis, ratios of RNA:DNA, and RNA:protein were compared among dietary treatments. To assess the degree of muscle protein mobilization in gestation and lactation, ratios of protein:DNA were compared among dietary treatments. Muscle samples were obtained from the triceps brachii. Blood and muscle samples were obtained 3 times: the first was obtained 1 d before the sows began to receive the experimental diets (90 +/- 3 d of gestation), a second sample was obtained 14 d later (104 +/- 3 d of gestation), and the third sample was obtained 10 d after farrowing. Serum ammonia concentrations were similar in sows fed the contaminated feed and sows fed the restricted feed compared with controls, but serum ammonia concentrations were greater in sows fed contaminated feed (P = 0.02) and restricted-fed sows (P = 0.008) compared with sows fed the contaminated grains plus GMA on 104 +/- 3 d of gestation. There were no reductions in the capacity for protein synthesis caused by mycotoxins or restricted feeding compared with controls. A reduction in ADFI (P = 0.003) was observed in sows fed the 2 contaminated diets in lactation. Muscle protein mobilization was not affected by diet, but a reduction (P = 0.04) in the content of protein per cellular unit was observed in lactation compared with gestation. Reduction in protein:DNA could be caused by the catabolic state in lactation, which was augmented by a low ADFI. The rate of muscle mobilization could be the result of the indirect effect of the reduction in ADFI in lactation rather than a direct effect of Fusarium mycotoxins in the capacity for protein synthesis.

  4. Low Dose Irradiation of Fresh and Fresh-Cut Produce

    USDA-ARS?s Scientific Manuscript database

    Foodborne illness (FBI) outbreaks in the United States associated with contaminated fruits, vegetables, salads, and juices have prompted redoubled efforts to improve agricultural, post-harvest and supply-chain controls that reduce risk. However, the lack of a broadly applicable antimicrobial process...

  5. Evaluation of microbial profile in dental unit waterlines and assessment of antimicrobial efficacy of two treating agents.

    PubMed

    Mungara, J; Dilna, N C; Joseph, E; Reddy, N

    2013-01-01

    The quality of water in a dental unit used for cooling and flushing the high and low speed handpiece, air/water syringes and the scalers is of considerable importance. The present study was carried out to enumerate and identify the microorganisms present in water samples collected from dental unit waterlines of different dental specialty clinics and to find out the efficacy of two treating agents in disinfecting dental unit waterlines. Sample included 70 dental unit waterlines from different speciality dental clinics which were checked for microbial contamination. From these dental units 40 units were randomly selected and divided into two groups of 20 each. Group A, treatment was done in 20 dental units with 0.2% Chlorhexidine gluconate solution and Group B, treatment was done in 20 dental units with 10% Povidone iodine solution and the reduction in the microbial levels were assessed. Five dental units were randomly selected and checked the microbial contamination using mineral water sterile distilled water fresh tap water as a water source in the dental unit reservoir bottles. Also from the test group, five from each group were checked for the duration of efficacy of treating agent for one week by analyzing the water samples collected on 3,5 and 7 day intervals. Most of the identified microorganisms are Gram negative and pseudomonas predominating up to 98.59% of the total isolates. Usage of disinfectants 0.2% Chlorhexidine and 10% Povidone Iodine were found to be very effective in reducing the microbial contamination and 10% Povidone iodine was found to be more efficient (97.13%) and active for a period of 3 days and gradually loosing its efficacy by 7th day. No significant difference were found in microbial contamination of water samples collected from different water outlets such as handpiece outlets, air water syringe outlets, scaler lines. To continue maintaining the sterility of the Dental unit waterlines and to complete the infection control measures adopted in the dental clinics, suitable disinfectants like 0.2% Chlorhexidine on daily basis or 10% Povidone iodine on every 3rd day basis intermittently maintain the sterility of dental unit waterlines it is essential to have a good water source and an effective disinfectant.

  6. Short communication: Inactivation of microbial contaminants in raw milk La Serena cheese by high-pressure treatments.

    PubMed

    Arqués, J L; Garde, S; Gaya, P; Medina, M; Nuñez, M

    2006-03-01

    La Serena cheese, a Spanish variety made from Merino ewes' raw milk, has a high pH value, low salt content, and high moisture, conditions that are all favorable for growth and survival of contaminating microorganisms, including pathogens. To improve its microbiological quality and safety, high-pressure treatments at 300 or 400 MPa for 10 min at 10 degrees C were applied to 2 batches of La Serena cheese on d 2 or 50 of ripening. Cheese treated on d 2 at 300 MPa showed viable aerobic counts that were 0.99 log units lower than those for control cheese on d 3 and showed counts of enterococci, coagulase-positive staphylococci, gram-negative bacteria, and coliforms that were 2.05, 0.49, 3.14, and 4.13 log units lower, respectively, than control cheese. For cheese treated on d 2 at 400 MPa, the respective reductions in counts were 2.02, 2.68, 1.45, 3.96, and 5.50 log units. On d 60, viable aerobic counts in cheese treated on d 50 at 300 MPa were 0.50 log units lower than those in control cheese, and counts of enterococci, gram-negative bacteria, and coliforms were 1.37, 2.30, and 4.85 log units lower, respectively. For cheese treated on d 50 at 400 MPa, the respective reductions in counts were 1.29, 1.98, 4.47, and > 5 log units. High-pressure treatments at 300 or 400 MPa on d 2 or 50 reduced significantly the counts of undesirable microorganisms, improving the microbiological quality and safety of La Serena cheese immediately after treatment and at the end of the ripening period.

  7. Occurrence and methods of control of chemical contaminants in foods.

    PubMed

    Jelinek, C

    1981-06-01

    Contamination of food by chemicals can result from their use on agricultural commodities; accidents or misuse during food handling and processing; nucler weapon testing and operation of nuclear power plants; and disposal of industrial chemicals or by-products with subsequent dispersal into the environment. The Food and Drug Administration (FDA), as the Federal agency mainly responsible for evaluating the hazards of chemical contaminants and enforcing any established tolerance levels for them in foods, has been monitoring pesticides, industrial chemicals, metals, and radionuclides in foods in its nationwide programs for many years. In addition, FDA searches for potential contaminants among the approximately 50,000 industrial chemicals manufactured in the United States and coordinates its efforts with those of other Federal and state agencies in these investigations. The overall results of the FDA surveillance and compliance programs for chemical contaminants in foods, as well as specific examples illustrating the wide range of incidents and types of occurrences, are presented.

  8. Biosensor for remote monitoring of airborne toxins

    NASA Astrophysics Data System (ADS)

    Knopf, George K.; Bassi, Amarjeet S.; Singh, Shikha; Macleod, Roslyn

    1999-12-01

    The rapid detection of toxic contaminants released into the air by chemical processing facilities is a high priority for many manufacturers. This paper describes a novel biosensor for the remote monitoring of toxic sites. The proposed biosensor is a measurement system that employs immobilized luminescent Vibrio fisheri bacteria to detect airborne contaminants. The presence of toxic chemicals will lead to a detectable decrease in the intensity of light produced by the bacteria. Both cellular and environmental factors control the bioluminescence of these bacteria. Important design factors are the appropriate cell growth media, environmental toxicity, oxygen and cell concentrations. The luminescent bacteria are immobilized on polyvinyl alcohol (PVA) gels and placed inside a specially constructed, miniature flow cell which houses a transducer, power source, and transmitter to convert the light signal information into radio frequencies that are picked up by a receiver at a remote location. The biosensor prototype is designed to function either as a single unit mounted on an exploratory robot or numerous units spatially distributed throughout a contaminated environment for remote sensing applications.

  9. [Identification of bacterial contamination in liquid soap for hospital use].

    PubMed

    Caetano, Joselany Afio; Lima, Maria Alzete; Di Ciero Miranda, Maira; Serufo, José Carlos; Ponte, Paulo Roberto Lins

    2011-03-01

    This study performed a bacteriological analysis of the liquid soap in dispensers that health professionals use for hand washing. This exploratory, cross-sectional study was developed at the hospitalization units of a medium-sized hospital in Fortaleza, Ceará, Brazil. Data were collected between May and July 2007. Fifty-nine liquid soap dispensers were analyzed, of which 33 contained the following microorganisms: Burkholderia cepacia (14), Pseudomonas putidas (9), Pseudomonas aeruginosa (3), Klebsiella pneumoniae (3), Enterobacter clocae (2), and Pseudomonas luteola (2). The units with the largest number of contaminated samples were the surgical (n=7) and the dermatological clinics (n=4). Contamination was also found in an original flask of the same lot of liquid soap used to fill up the dispensers. In conclusion, there is a need to regulate and control the quality of these products in the production lines as well as during use in hospital services, mainly because they are used to prevent hospital infection.

  10. Contamination delays the release of Laricobius osakensis for biological control of hemlock woolly adelgid: cryptic diversity in Japanese Laricobius spp

    Treesearch

    Melissa J. Fischer; Nathan P. Havill; Carrie S. Jubb; Sean W. Prosser; Brent D. Opell; Scott M. Salom; Loke T. Kok

    2014-01-01

    Laricobius osakensis (Coleoptera: Derodontidae) was imported from Japan to the United States in 2006 for study in quarantine facilities as a potential biological control of Hemlock Woolly Adelgid. Laricobius osakensis was released from quarantine in 2010, but it was soon discovered that the colony also contained a cryptic species...

  11. Control of endemic nosocomial legionnaires' disease by using sterile potable water for high risk patients.

    PubMed Central

    Marrie, T. J.; Haldane, D.; MacDonald, S.; Clarke, K.; Fanning, C.; Le Fort-Jost, S.; Bezanson, G.; Joly, J.

    1991-01-01

    In a setting where potable water is contaminated with Legionella pneumophila serogroup 1, we performed two case control studies. The first case control study consisted of 17 cases of nosocomial Legionnaires' disease (LD) and 33 control (the patients who were admitted to the ward where the case was admitted immediately before and after the case) subjects. Cases had a higher mortality rate 65% vs 12% (P less than 0.004); were more likely to have received assisted ventilation (P less than 0.00001); to have nasogastric tubes (P less than 0.0004) and to be receiving corticosteroids or other immunosuppressive therapy (P less than 0.0001). Based on the results of this study, sterile water was used to flush nasogastric tubes and to dilute nasogastric feeds. Only 3 cases of nosocomial LD occurred during the next year compared with 12 the previous year (P less than 0.0001). Nine cases subsequently occurred and formed the basis for the second case-control study. Eighteen control subjects were those patients admitted to the same unit where the case developed LD, immediately before and after the case. The mortality rate for the cases was 89% vs 6% for controls (P less than 0.00003). The only other significant difference was that cases were more likely to be receiving corticosteroids or other immunosuppressive therapy 89% vs 39% (less than 0.01). We hypothesized that microaspiration of contaminated potable water by immunocompromised patients was a risk factor for nosocomial Legionnaires' disease. From 17 March 1989 onwards such patients were given only sterile potable water. Only two cases of nosocomial LD occurred from June 1989 to September 1990 and both occurred on units where the sterile water policy was not in effect. We conclude that aspiration of contaminated potable water is a possible route for acquisition of nosocomial LD in our hospital and that provision of sterile potable water to high risk patients (those who are receiving corticosteroids or other immunosuppressive drugs; organ transplant recipients or hospitalized in an intensive care unit) should be mandatory. PMID:1752308

  12. Some recent developments in spacecraft environmental control/life support subsystems

    NASA Technical Reports Server (NTRS)

    Gillen, R. J.; Olcott, T. M.

    1974-01-01

    The subsystems considered include a flash evaporator for heat rejection, a regenerable carbon dioxide and humidity control subsystem, an iodinating subsystem for potable water, a cabin contaminant control subsystem, and a wet oxidation subsystem for processing spacecraft wastes. The flash evaporator discussed is a simple unit which efficiently controls life support system temperatures over a wide range of heat loads. For certain advanced spacecraft applications the control of cabin carbon dioxide and humidity can be successfully achieved by a regenerable solid amine subsystem.

  13. Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor

    NASA Technical Reports Server (NTRS)

    Wallace, D. A.

    1980-01-01

    A thermoelectrically temperature controlled quartz crystal microbalance (QCM) system was developed for the measurement of ion thrustor generated mercury contamination on spacecraft. Meaningful flux rate measurements dictated an accurately held sensing crystal temperature despite spacecraft surface temperature variations from -35 C to +60 C over the flight temperature range. An electronic control unit was developed with magentic amplifier transformer secondary power supply, thermal control electronics, crystal temperature analog conditioning and a multiplexed 16 bit frequency encoder.

  14. Clarification of Institutional Controls at the Rocky Flats Site Central Operable Unit and Implementation of the Soil Disturbance Review Plan - 13053

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiSalvo, Rick; Surovchak, Scott; Spreng, Carl

    2013-07-01

    Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plantmore » (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)« less

  15. Radionuclides in surface and groundwater

    USGS Publications Warehouse

    Campbell, Kate M.

    2009-01-01

    Unique among all the contaminants that adversely affect surface and water quality, radioactive compounds pose a double threat from both toxicity and damaging radiation. The extreme energy potential of many of these materials makes them both useful and toxic. The unique properties of radioactive materials make them invaluable for medical, weapons, and energy applications. However, mining, production, use, and disposal of these compounds provide potential pathways for their release into the environment, posing a risk to both humans and wildlife. This chapter discusses the sources, uses, and regulation of radioactive compounds in the United States, biogeochemical processes that control mobility in the environment, examples of radionuclide contamination, and current work related to contaminated site remediation.

  16. Surface microbial contamination in hospitals: A pilot study on methods of sampling and the use of proposed microbiologic standards.

    PubMed

    Claro, Tânia; O'Reilly, Marese; Daniels, Stephen; Humphreys, Hilary

    2015-09-01

    Contamination of hospital surfaces by bacteria is increasingly recognized. We assessed commonly touched surfaces using contact plates and Petrifilms (3M, St. Paul, MN) and compared the results against proposed microbiology standards. Toilet door handles were the most heavily contaminated (7.97 ± 0.68 colony forming units [CFU]/cm(2)) and exceeded proposed standards on 74% of occasions. Petrifilms detected statistically higher CFU from bedside lockers. Further research is required on the use of standards and methods of sampling. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Modelling of sequential groundwater treatment with zero valent iron and granular activated carbon.

    PubMed

    Bayer, Peter; Finkel, Michael

    2005-06-01

    Multiple contaminant mixtures in groundwater may not efficiently be treated by a single technology if contaminants possess rather different properties with respect to sorptivity, solubility, and degradation potential. An obvious choice is to use sequenced units of the generally accepted treatment materials zero valent iron (ZVI) and granular activated carbon (GAC). However, as the results of this modelling study suggest, the required dimensions of both reactor units may strongly differ from those expected on the grounds of a contaminant-specific design. This is revealed by performing an analysis for a broad spectrum of design alternatives through numerical experiments for selected patterns of contaminant mixtures consisting of monochlorobenzene, tetrachloroethylene, trichloroethylene (TCE), cis-1,2-dichloroethylene (cis-DCE), and vinyl chloride (VC). It is shown that efficient treatment can be achieved only if competitive sorption effects in the GAC unit as well as the formation of intermediate products in the ZVI unit are carefully taken into account. Cost-optimal designs turned out to vary extremely depending on the prevailing conditions concerning contaminant concentrations, branching ratios, and unit costs of both reactor materials. Where VC is the critical contaminant, due to high initial concentration or extensive production as an intermediate, two options are cost-effective: an oversized ZVI unit with an oversized GAC unit or a pure GAC reactor.

  18. Survey of Salmonella contamination of non-United Kingdom-produced raw shell eggs on retail sale in the northwest of England and London, 2005 to 2006.

    PubMed

    Little, C L; Walsh, S; Hucklesby, L; Surman-Lee, S; Pathak, K; Gatty, Y; Greenwood, M; De Pinna, E; Threlfall, E J; Maund, A; Chan, C H

    2007-10-01

    This survey was prompted by a change in the epidemiology of Salmonella Enteritidis infections in England and Wales and elsewhere in Europe and, to our knowledge, is the first survey to provide information on Salmonella contamination of non-United Kingdom eggs on retail sale. Based on 10,464 non-United Kingdom eggs (1744 pooled samples of six eggs) purchased between March 2005 and July 2006, the total weighted prevalence estimate for all Salmonella detected in non-United Kingdom eggs was 3.3%. Of the eggs sampled, most were produced in Spain (66.3%), France (20.0%), or The Netherlands (7.4%). Salmonella was detected from 4.4 and 0.3% of eggs produced in Spain and France, respectively, with weighted prevalence estimates. Eight different Salmonella serotypes were recovered from non-United Kingdom eggs, of which Salmonella Enteritidis predominated, with an estimated prevalence of 2.6%. Salmonella Enteritidis was obtained only from Spanish eggs. Nine different phage types of Salmonella Enteritidis were identified, with phage type 1 found to be the predominant phage type. Most of the Salmonella Enteritidis isolates obtained from Spanish eggs in the survey were resistant to nalidixic acid with concomitant decreased susceptibility to ciprofloxacin (0.125 to 1.0 mg/liter) or ampicillin (8.0 mg/liter). Salmonella Enteritidis phage type 1 until now had not been detected in eggs examined as part of previous United Kingdom egg surveys but has been detected in eggs of Spanish origin examined during recent national outbreaks of Salmonella Enteritidis non-phage type 4 infections in England and Wales. Eggs are a commonly consumed food that may occasionally be contaminated with Salmonella. The rates of contamination may be linked to the origin of the eggs. Consumers and caterers need to be aware of this continuing hazard, adopt appropriate control measures, and follow advice provided by national food agencies in order to reduce the risk of infection.

  19. Skin antiseptics in venous puncture site disinfection for preventing blood culture contamination: A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Liu, Wenjie; Duan, Yuchen; Cui, Wenyao; Li, Li; Wang, Xia; Dai, Heling; You, Chao; Chen, Maojun

    2016-07-01

    To compare the efficacy of several antiseptics in decreasing the blood culture contamination rate. Network meta-analysis. Electronic searches of PubMed and Embase were conducted up to November 2015. Only randomized controlled trials or quasi-randomized controlled trials were eligible. We applied no language restriction. A comprehensive review of articles in the reference lists was also accomplished for possible relevant studies. Relevant studies evaluating efficacy of different antiseptics in venous puncture site for decreasing the blood culture contamination rate were included. The data were extracted from the included randomized controlled trials by two authors independently. The risk of bias was evaluated using Detsky scale by two authors independently. We used WinBUGS1.43 software and statistic model described by Chaimani to perform this network meta-analysis. Then graphs of statistical results of WinBUGS1.43 software were generated using 'networkplot', 'ifplot', 'netfunnel' and 'sucra' procedure by STATA13.0. Odds ratio and 95% confidence intervals were assessed for dichotomous data. A probability of p less than 0.05 was considered to be statistically significant. Compared with ordinary meta-analyses, this network meta-analysis offered hierarchies for the efficacy of different antiseptics in decreasing the blood culture contamination rate. Seven randomized controlled trials involving 34,408 blood samples were eligible for the meta-analysis. No significant difference was found in blood culture contamination rate among different antiseptics. No significant difference was found between non-alcoholic antiseptics and alcoholic antiseptics, alcoholic chlorhexidine and povidone iodine, chlorhexidine and iodine compounds, povidone iodine and iodine tincture in this aspect, respectively. Different antiseptics may not affect the blood culture contamination rate. Different intervals between the skin disinfection and the venous puncture, the different settings (emergency room, medical wards, and intensive care units) and the performance of the phlebotomy may affect the blood culture contamination rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Ultra Low Volume Dispersal of Insecticides by Ground Equipment

    DTIC Science & Technology

    1999-12-01

    Chairman) CPT Lewis Boobar, MS, USA (Vice Chairman) Mr. Joseph Deschenes Mr. Sam Jerry Ellis Mr. Felix M. Huertas Dr. James H. Nelson Mr...methods introduced since 1960 in an effort to improve flying insect control. Primary emphasis is placed on ground control techniques; however, aerial...the atomizing head, interior solenoid valve mechanisms, pump assemblies , and exterior portions of the dispersal unit subject to liquid contamination

  1. Remediation by Natural Attenuation Treatability Study for Operable Unit 5

    DTIC Science & Technology

    1997-12-01

    remaining as a result of all attenuation processes is equivalent to the fraction of contaminant remaining as a result of non - destructive attenuation...Alternative 1-- RNA Combined with LTM, Institutional Controls , Air Sparging Along Main Street, and Groundwater Extraction and Treatment Near Well Pair MW137...MW138 .............................. 6-4 6.3.2 Alternative 2 -- RNA, LTM, Institutional Controls , Air Sparging along Main Street, Groundwater

  2. Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

    PubMed

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S; Valente, Sabrina; Farruggia, Patrizia; Sabattini, Maria A Bucci; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-02-18

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

  3. Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices

    PubMed Central

    Dallolio, Laura; Scuderi, Amalia; Rini, Maria S.; Valente, Sabrina; Farruggia, Patrizia; Bucci Sabattini, Maria A.; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica

    2014-01-01

    Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions. PMID:24552789

  4. Microbiological contamination in digital radiography: evaluation at the radiology clinic of an educational institution.

    PubMed

    Malta, Cristiana P; Damasceno, Naiana Nl; Ribeiro, Rosangela A; Silva, Carolina Sf; Devito, Karina L

    2016-12-01

    The aim of this study was to evaluate the contamination rate of intra and extraoral digital X ray equipment in a dental radiology clinic at a public educational institution. Samples were collected on three different days, at two times in the day: in the morning, before attending patients, and at the end of the day, after appointment hours and before cleaning and disinfection procedures. Samples were collected from the periapical X-ray machine (tube head, positioning device, control panel and activator button), the panoramic X- ray machine (temporal support, bite block, control panel and activator button), the intraoral digital system (sensor), and the digital system computers (keyboard and mouse). The samples were seeded in different culture media, incubated, and colony forming units (CFU/mL) counted. Biochemical tests were performed for suspected colonies of Staphylococcus, Streptococcus and Gramnegative bacilli (GNB). Fungi were visually differentiated into filamentous fungi and yeasts. The results indicated the growth of fungi and Staphylococcus fromall sampling locations. GNB growth was observed from all sites sampled from the intraoral X-ray equipment. On the panoramic unit, GNB growth was observed in samples from activator button, keyboard and mouse. In general, a higher number of CFU/mL was present before use. It can be concluded that more stringent protocols are needed to control infection and prevent X-ray exams from acting as vehicle for cross contamination. Sociedad Argentina de Investigación Odontológica.

  5. Occurrence of Non-Tuberculous Mycobacteria at an Acute Care Hospital Using Secondary Drinking Water Treatment

    EPA Science Inventory

    The development of infection control strategies at acute-care hospitals has contributed to an overall decline in the number of healthcare-associated infections (HAI’s) in the United States, especially those caused by contaminated equipment used in surgical procedures and co...

  6. Food Safety and Intervention Technologies Research: Cold Plasma as a Nonthermal food processing technology

    USDA-ARS?s Scientific Manuscript database

    Contamination of meats, seafood, poultry, eggs, and fresh and fresh-cut fruits and vegetables is an ongoing concern. The Food Safety and Intervention Technologies Research Unit develops and validates innovative approaches and new technologies that control pathogenic bacteria and viruses while preser...

  7. Food Safety and Intervention Technologies research: cold plasma as a nonthermal food processing technology

    USDA-ARS?s Scientific Manuscript database

    Contamination of meats, seafood, poultry, eggs, and fresh and fresh-cut fruits and vegetables is an ongoing concern. The Food Safety and Intervention Technologies Research Unit develops and validates innovative approaches and new technologies that control pathogenic bacteria and viruses while preser...

  8. Food for Thought - The Use of Hazard and Critical Control Point Analysis to Assess Vulnerability of Food to Terrorist Attack in Deployment Locations, A Case Study

    DTIC Science & Technology

    1997-01-01

    employing food have not kept pace with the potential threat to food safety . Recommendations to potentially decrease the vulnerability of the United States military food supply to intentional contamination are also provided.

  9. THE UNITED STATES EPA CONCEPT FOR DERIVING WATER QUALITY GUIDELINES FOR RECREATIONAL WATERS

    EPA Science Inventory

    The guidelines developed by the US EPA for controlling the quality of recreational waters are based on protecting the health of swimmers and other recreationists who may be exposed to waters contaminated by human and animal excreta. Risks to swimmers were determined through a se...

  10. Partial least squares models for hyperspectral contaminant detection

    USDA-ARS?s Scientific Manuscript database

    The United States of America food supply is one of the safest in the world. However, it is not free of pathogens. For the poultry industry, the Food Safety Inspection Service (FSIS) has regulatory responsiblity for food safety and has established a hazard analysis, critical control point system (HAC...

  11. The incidence of blood contamination of lead unit dose containers with and without single-use protective inserts used with commercially prepared radiopharmaceutical unit doses.

    PubMed

    Pickett, M W; Kosegi, J E; Thomas, K S; Waterstram-Rich, K M

    1998-09-01

    This investigation evaluated the effectiveness of disposable plastic inserts in radiopharmaceutical unit dose lead containers (pigs) in preventing the distribution of doses in blood-contaminated containers. Technologists commonly dispose of the syringes by placing them into the lead pigs, leaving the needles uncapped. This process raises the question of unsuspected blood contamination of these pigs. Consequently, the distribution of commercially prepared radiopharmaceutical doses in reusable lead pigs may result in radiopharmaceutical doses being distributed in containers that are contaminated with blood. Using a simple chemical wipe test designed to determine the presence or absence of blood contamination, 618 pigs from commercial radiopharmacies throughout the U.S. were tested for contamination. The inside of the pigs and inserts, if present, were wiped before and after dose administration. Of the pigs tested, 292 came from radiopharmacies that used a protective, disposable plastic insert inside the pig, and 326 came from radiopharmacies that did not use an insert. Of those pigs without the protective disposable inserts, 39.3% arrived in the nuclear medicine department in pigs contaminated with blood. Of those pigs with inserts, 1% arrived with blood-contaminated inserts. After dose administration, 46.3% of the pigs without inserts were contaminated with blood and 3% of the protective inserts were contaminated. The proper use of disposable plastic inserts reduces the possibility of distributing radiopharmaceutical unit doses in containers contaminated with blood.

  12. Predicting geogenic arsenic contamination in shallow groundwater of south Louisiana, United States.

    PubMed

    Yang, Ningfang; Winkel, Lenny H E; Johannesson, Karen H

    2014-05-20

    Groundwater contaminated with arsenic (As) threatens the health of more than 140 million people worldwide. Previous studies indicate that geology and sedimentary depositional environments are important factors controlling groundwater As contamination. The Mississippi River delta has broadly similar geology and sedimentary depositional environments to the large deltas in South and Southeast Asia, which are severely affected by geogenic As contamination and therefore may also be vulnerable to groundwater As contamination. In this study, logistic regression is used to develop a probability model based on surface hydrology, soil properties, geology, and sedimentary depositional environments. The model is calibrated using 3286 aggregated and binary-coded groundwater As concentration measurements from Bangladesh and verified using 78 As measurements from south Louisiana. The model's predictions are in good agreement with the known spatial distribution of groundwater As contamination of Bangladesh, and the predictions also indicate high risk of As contamination in shallow groundwater from Holocene sediments of south Louisiana. Furthermore, the model correctly predicted 79% of the existing shallow groundwater As measurements in the study region, indicating good performance of the model in predicting groundwater As contamination in shallow aquifers of south Louisiana.

  13. Initial comparison of single cylinder Stirling engine computer model predictions with test results

    NASA Technical Reports Server (NTRS)

    Tew, R. C., Jr.; Thieme, L. G.; Miao, D.

    1979-01-01

    A NASA developed digital computer code for a Stirling engine, modelling the performance of a single cylinder rhombic drive ground performance unit (GPU), is presented and its predictions are compared to test results. The GPU engine incorporates eight regenerator/cooler units and the engine working space is modelled by thirteen control volumes. The model calculates indicated power and efficiency for a given engine speed, mean pressure, heater and expansion space metal temperatures and cooler water inlet temperature and flow rate. Comparison of predicted and observed powers implies that the reference pressure drop calculations underestimate actual pressure drop, possibly due to oil contamination in the regenerator/cooler units, methane contamination in the working gas or the underestimation of mechanical loss. For a working gas of hydrogen, the predicted values of brake power are from 0 to 6% higher than experimental values, and brake efficiency is 6 to 16% higher, while for helium the predicted brake power and efficiency are 2 to 15% higher than the experimental.

  14. Regenerable Air Purification System for Gas-Phase Contaminant Control

    NASA Technical Reports Server (NTRS)

    Constantinescu, Ileana C.; Qi, Nan; LeVan, M. Douglas; Finn, Cory K.; Finn, John E.; Luna, Bernadette (Technical Monitor)

    2000-01-01

    A regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an. adsorbent column into a closed oxidation loop is under development through cooperative R&D between Vanderbilt University and NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. Recent work has focused on fabrication and operation of a RAPS breadboard at NASA Ames, and on measurement of adsorption isotherm data for several important organic compounds at Vanderbilt. These activities support the use and validation of RAPS modeling software also under development at Vanderbilt, which will in turn be used to construct a prototype system later in the project.

  15. The Association Between Extreme Precipitation and Waterborne Disease Outbreaks in the United States, 1948–1994

    PubMed Central

    Curriero, Frank C.; Patz, Jonathan A.; Rose, Joan B.; Lele, Subhash

    2001-01-01

    Objectives. Rainfall and runoff have been implicated in site-specific waterborne disease outbreaks. Because upward trends in heavy precipitation in the United States are projected to increase with climate change, this study sought to quantify the relationship between precipitation and disease outbreaks. Methods. The US Environmental Protection Agency waterborne disease database, totaling 548 reported outbreaks from 1948 through 1994, and precipitation data of the National Climatic Data Center were used to analyze the relationship between precipitation and waterborne diseases. Analyses were at the watershed level, stratified by groundwater and surface water contamination and controlled for effects due to season and hydrologic region. A Monte Carlo version of the Fisher exact test was used to test for statistical significance. Results. Fifty-one percent of waterborne disease outbreaks were preceded by precipitation events above the 90th percentile (P = .002), and 68% by events above the 80th percentile (P = .001). Outbreaks due to surface water contamination showed the strongest association with extreme precipitation during the month of the outbreak; a 2-month lag applied to groundwater contamination events. Conclusions. The statistically significant association found between rainfall and disease in the United States is important for water managers, public health officials, and risk assessors of future climate change. PMID:11499103

  16. Unit Process Wetlands for Removal of Trace Organic Contaminants and Pathogens from Municipal Wastewater Effluents

    PubMed Central

    Jasper, Justin T.; Nguyen, Mi T.; Jones, Zackary L.; Ismail, Niveen S.; Sedlak, David L.; Sharp, Jonathan O.; Luthy, Richard G.; Horne, Alex J.; Nelson, Kara L.

    2013-01-01

    Abstract Treatment wetlands have become an attractive option for the removal of nutrients from municipal wastewater effluents due to their low energy requirements and operational costs, as well as the ancillary benefits they provide, including creating aesthetically appealing spaces and wildlife habitats. Treatment wetlands also hold promise as a means of removing other wastewater-derived contaminants, such as trace organic contaminants and pathogens. However, concerns about variations in treatment efficacy of these pollutants, coupled with an incomplete mechanistic understanding of their removal in wetlands, hinder the widespread adoption of constructed wetlands for these two classes of contaminants. A better understanding is needed so that wetlands as a unit process can be designed for their removal, with individual wetland cells optimized for the removal of specific contaminants, and connected in series or integrated with other engineered or natural treatment processes. In this article, removal mechanisms of trace organic contaminants and pathogens are reviewed, including sorption and sedimentation, biotransformation and predation, photolysis and photoinactivation, and remaining knowledge gaps are identified. In addition, suggestions are provided for how these treatment mechanisms can be enhanced in commonly employed unit process wetland cells or how they might be harnessed in novel unit process cells. It is hoped that application of the unit process concept to a wider range of contaminants will lead to more widespread application of wetland treatment trains as components of urban water infrastructure in the United States and around the globe. PMID:23983451

  17. Unit Process Wetlands for Removal of Trace Organic Contaminants and Pathogens from Municipal Wastewater Effluents.

    PubMed

    Jasper, Justin T; Nguyen, Mi T; Jones, Zackary L; Ismail, Niveen S; Sedlak, David L; Sharp, Jonathan O; Luthy, Richard G; Horne, Alex J; Nelson, Kara L

    2013-08-01

    Treatment wetlands have become an attractive option for the removal of nutrients from municipal wastewater effluents due to their low energy requirements and operational costs, as well as the ancillary benefits they provide, including creating aesthetically appealing spaces and wildlife habitats. Treatment wetlands also hold promise as a means of removing other wastewater-derived contaminants, such as trace organic contaminants and pathogens. However, concerns about variations in treatment efficacy of these pollutants, coupled with an incomplete mechanistic understanding of their removal in wetlands, hinder the widespread adoption of constructed wetlands for these two classes of contaminants. A better understanding is needed so that wetlands as a unit process can be designed for their removal, with individual wetland cells optimized for the removal of specific contaminants, and connected in series or integrated with other engineered or natural treatment processes. In this article, removal mechanisms of trace organic contaminants and pathogens are reviewed, including sorption and sedimentation, biotransformation and predation, photolysis and photoinactivation, and remaining knowledge gaps are identified. In addition, suggestions are provided for how these treatment mechanisms can be enhanced in commonly employed unit process wetland cells or how they might be harnessed in novel unit process cells. It is hoped that application of the unit process concept to a wider range of contaminants will lead to more widespread application of wetland treatment trains as components of urban water infrastructure in the United States and around the globe.

  18. Occurrence and methods of control of chemical contaminants in foods.

    PubMed Central

    Jelinek, C

    1981-01-01

    Contamination of food by chemicals can result from their use on agricultural commodities; accidents or misuse during food handling and processing; nucler weapon testing and operation of nuclear power plants; and disposal of industrial chemicals or by-products with subsequent dispersal into the environment. The Food and Drug Administration (FDA), as the Federal agency mainly responsible for evaluating the hazards of chemical contaminants and enforcing any established tolerance levels for them in foods, has been monitoring pesticides, industrial chemicals, metals, and radionuclides in foods in its nationwide programs for many years. In addition, FDA searches for potential contaminants among the approximately 50,000 industrial chemicals manufactured in the United States and coordinates its efforts with those of other Federal and state agencies in these investigations. The overall results of the FDA surveillance and compliance programs for chemical contaminants in foods, as well as specific examples illustrating the wide range of incidents and types of occurrences, are presented. PMID:6786871

  19. Contaminant Attenuation and Transport Characterization of 200-DV-1 Operable Unit Sediment Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Truex, Michael J.; Szecsody, James E.; Qafoku, Nikolla

    2017-05-15

    A laboratory study was conducted to quantify contaminant attenuation processes and associated contaminant transport parameters that are needed to evaluate transport of contaminants through the vadose zone to the groundwater. The laboratory study information, in conjunction with transport analyses, can be used as input to evaluate the feasibility of Monitored Natural Attenuation and other remedies for the 200-DV-1 Operable Unit at the Hanford Site.

  20. Application of a geographic information system in analyzing the occurrence of atrazine in groundwater of the mid-continental United States

    USGS Publications Warehouse

    Burkart, M.R.; Kolpin, D.W.

    1993-01-01

    The US Geological Survey, US Department of Agriculture, and US Environmental Protection Agency are conducting research and regional assessments in support of policy alternatives intended to protect water resources from agricultural chemical contamination. The mid-continent was selected because of the intense row crop agriculture and associated herbicide application in this region. An application of a geographic information system is demonstrated for analyzing and comparing the distribution of estimated atrazine use to the detection rate of atrazine in groundwater. Understanding the relations between atrazine use and detection in groundwater is important in policy deliberations to protect water resources. Relational analyses between measures of chemical use and detection rate by natural resource units may provide insight into critical factors controlling the processes that result in groundwater contamination from agricultural chemicals. 

  1. What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit.

    PubMed

    Russotto, Vincenzo; Cortegiani, Andrea; Fasciana, Teresa; Iozzo, Pasquale; Raineri, Santi Maurizio; Gregoretti, Cesare; Giammanco, Anna; Giarratano, Antonino

    2017-01-01

    Intensive care unit- (ICU-) acquired infections are a major health problem worldwide. Inanimate surfaces and equipment contamination may play a role in cross-transmission of pathogens and subsequent patient colonization or infection. Bacteria contaminate inanimate surfaces and equipment of the patient zone and healthcare area, generating a reservoir of potential pathogens, including multidrug resistant species. Traditional terminal cleaning methods have limitations. Indeed patients who receive a bed from prior patient carrying bacteria are exposed to an increased risk (odds ratio 2.13, 95% confidence intervals 1.62-2.81) of being colonized and potentially infected by the same bacterial species of the previous patient. Biofilm formation, even on dry surfaces, may play a role in reducing the efficacy of terminal cleaning procedures since it enables bacteria to survive in the environment for a long period and provides increased resistance to commonly used disinfectants. No-touch methods (e.g., UV-light, hydrogen peroxide vapour) are under investigation and further studies with patient-centred outcomes are needed, before considering them the standard of terminal cleaning in ICUs. Healthcare workers should be aware of the role of environmental contamination in the ICU and consider it in the broader perspective of infection control measures and stewardship initiatives.

  2. X-231B technology demonstration for in situ treatment of contaminated soil: Contaminant characterization and three dimensional spatial modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, O.R.; Siegrist, R.L.; Mitchell, T.J.

    1993-11-01

    Fine-textured soils and sediments contaminated by trichloroethylene (TCE) and other chlorinated organics present a serious environmental restoration challenge at US Department of Energy (DOE) sites. DOE and Martin Marietta Energy Systems, Inc. initiated a research and demonstration project at Oak Ridge National Laboratory. The goal of the project was to demonstrate a process for closure and environmental restoration of the X-231B Solid Waste Management Unit at the DOE Portsmouth Gaseous Diffusion Plant. The X-231B Unit was used from 1976 to 1983 as a land disposal site for waste oils and solvents. Silt and clay deposits beneath the unit were contaminatedmore » with volatile organic compounds and low levels of radioactive substances. The shallow groundwater was also contaminated, and some contaminants were at levels well above drinking water standards. This document begins with a summary of the subsurface physical and contaminant characteristics obtained from investigative studies conducted at the X-231B Unit prior to January 1992 (Sect. 2). This is then followed by a description of the sample collection and analysis methods used during the baseline sampling conducted in January 1992 (Sect. 3). The results of this sampling event were used to develop spatial models for VOC contaminant distribution within the X-231B Unit.« less

  3. CY2017 Annual Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada: (January 2017–December 2017), Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rehfeldt, Ken; Haight, Brian

    Corrective Action Unit (CAU) 98: Frenchman Flat on the Nevada National Security Site was the location of 10 underground nuclear tests. CAU 98 underwent a series of investigations and actions in accordance with the Federal Facility Agreement and Consent Order to assess contamination of groundwater by radionuclides from the tests. A Closure Report completed that process in 2016 and called for long-term monitoring, use restrictions (URs), and institutional controls to protect the public and environment from potential exposure to contaminated groundwater. Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are monitoredmore » to determine whether the URs remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Monitoring data will be used in the future, once multiple years of data are available, to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries calculated with the models are the primary basis of the UR boundaries. Six wells were sampled for water-quality monitoring in 2017. Contaminants of concern were detected only in the two source/plume wells already known to contain contamination as a result of a radionuclide migration experiment. The 86,000-picocuries-per-liter (pCi/L) tritium concentration in one of the wells is about 12 percent higher than measured in 2016 but is over an order of magnitude less than the peak value measured in the well in 1980. The concentration in the other source/plume well is lower than measured in 2016. The water-level monitoring network includes 16 wells. Depth to water measured in 2017 is generally consistent with recent measurements for most wells. Water-level declines differing from long-term trends were observed in four wells. Three of these (WW-4, WW-4A, and WW-5B) are water-supply wells that experienced increases in pumping during the year. No definitive cause for the sharp decline in the fourth well (ER-5-3-2) in 2016 is known as yet. Institutional control monitoring confirmed the URs are recorded in U.S. Department of Energy and U.S. Air Force land management systems, and that no activities within Frenchman Flat basin are occurring that could potentially affect the contaminant boundaries. Survey of groundwater resources in basins surrounding Frenchman Flat similarly identify no current or pending development that would indicate the need to increase monitoring activities or would otherwise cause concern for the closure decision. The URs continue to prevent exposure of the public, workers, and the environment to contaminants of concern by preventing use of potentially contaminated groundwater.« less

  4. Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions.

    PubMed

    Eder, Anne F; Dy, Beth A; DeMerse, Barbara; Wagner, Stephen J; Stramer, Susan L; O'Neill, E Mary; Herron, Ross M

    2017-12-01

    Apheresis technology to collect platelet (PLT) components differs among devices. We evaluated the relationship of the plateletpheresis device with bacterial contamination and reported septic transfusion reactions. Plateletpheresis was performed using Amicus (Fenwal, a Fresenius Kabi Company) or Trima (Trima Accel, TerumoBCT) from 2010 to 2014. All donations used inlet-line sample diversion and were tested by quality control (QC; Day 1) aerobic culture. Rates of bacterial contamination and septic reactions to PLTs were calculated for both devices. During the 5-year study period, plateletpheresis collections using Amicus and Trima devices totaled 1,486,888 and 671,955 donations, respectively. The rate of confirmed-positive bacterial cultures of apheresis PLT donations was significantly higher with Amicus than with Trima (252 vs. 112 per 10 6 donations [odds ratio {OR}, 2.3; 95% confidence interval {CI}, 1.8-2.9]). Septic transfusion reactions were caused by 30 apheresis PLT units from 25 contaminated Amicus procedures and three apheresis PLT units from three contaminated Trima procedures. The overall rate of septic reactions was significantly higher with apheresis PLT components collected with Amicus than with Trima (16.8 vs. 4.5 per 10 6 donations [OR, 3.8; 95% CI, 1.1-12.5]). All apheresis PLT components implicated in septic transfusion reactions had negative QC culture results incubated through Day 5 (i.e., false negatives). Apheresis technology affects bacterial contamination of plateletpheresis collections. The device-specific, higher rate of confirmed-positive bacterial culture results also correlated with a significantly higher rate of reported septic transfusion reactions to apheresis PLTs. © 2017 AABB.

  5. First report of Penicillium expansum isolates resistant to pyrimethanil from stored apple fruit in Pennsylvania

    USDA-ARS?s Scientific Manuscript database

    Apples in the United States are stored in low temperature controlled atmosphere for 9–12 months and are susceptible to decay by blue mold. Penicillium spp. cause significant economic losses worldwide and produce mycotoxins that contaminate processed apple products. Blue mold is managed by a combinat...

  6. Microbial contamination of the Tzu-Chi Cord Blood Bank from 2005 to 2006.

    PubMed

    Chen, Shu-Huey; Zheng, Ya-Jun; Yang, Shang-Hsien; Yang, Kuo-Liang; Shyr, Ming-Hwang; Ho, Yu-Huai

    2008-01-01

    In total, 4502 units of cord blood (CB) were collected during a 2-year period from 2005 to 2006 by the Buddhist Tzu-Chi Stem Cells Center. The aim of this study was to analyze the incidence of microbial contamination and type of organism present in the cord blood. The clinical impact of microbial contamination on hematopoietic progenitor cell (HPC) grafts used for HPC transplantation is also discussed. First and second specimens were obtained for microbial assessment. These were collected in laboratory after cord blood collection and after cord blood unit manipulation, respectively. The samples were cultured and the results reviewed. The overall incidence of microbiological contamination was 1.8% (82/4502). Three CB units were contaminated with two different organisms. Infectious organisms comprised 9.4% (8/85) of total isolated microbes. These infectious microorganisms were beta-Streptococci group B, Candida tropicalis and Staphylococcus aureus which were isolated in 6, 1 and 1 of CB units respectively. Escherichia coli, Bacteroides fragilis, Lactobacillus spp., Enterococcus, beta-Streptococcus Group B, Bacteroides valgatus, Corynebacterium spp., Klebsiella pneumonia and Peptococcus spp. were the most frequently encountered microorganisms. A higher contamination rate of the CB units was noted after vaginal delivery (2.16%) compared to caesarian section (0.85%) (p < 0.01). Extensive training in CB collection, good procedures and good protocols can decrease the rate of microbial contamination. The use of a closed collecting system and an ex utero method have the advantage of a lower contamination rate. In our cord blood bank, we use a closed system but an in utero method. Similar to other studies, most of microorganisms reported here as contaminants are non-pathogenic.

  7. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus.

    PubMed

    Petti, S; Messano, G A

    2016-05-01

    Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (P<0.01). Log MRSA density reduction attributable to PCD was 1.16logcfu/cm(2), corresponding to 93% reduction of the baseline MRSA contamination. The disinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (<1cfu/cm(2)), but required 3h of exposure to photocatalysis. Thus, PCD could be considered for non-clinical surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. [Damage control in trauma patients with hemodynamic instability].

    PubMed

    Müller, Thorben; Doll, Dietrich; Kliebe, Frank; Ruchholtz, Steffen; Kühne, Christian

    2010-10-01

    The term "Damage-control" is borrowed from naval terminology. It means the initial control of a damaged ship. Because of the lethal triad in multiple injured patients the classical concept of definitive surgically therapy in the acute phase of the injury has a high rate of complications such as exsanguination, sepsis, heart failure and multiple organ failure. The core idea of the damage control concept was to minimize the additional trauma by surgical operations in these critical patients in the first phase. This means temporary control of a hemorrhage and measures for stopping abdominal contamination. After 24 - 48 hours in the intensive care unit and correction of physiological disturbances further interventions are performed for definitively treatment of the injuries. Summarized, the damage control strategy comprises an abbreviated operation, intensive care unit resuscitation, and a return to the operating room for the definitive operation after hemodynamic stabilisation of the patient. © Georg Thieme Verlag Stuttgart · New York.

  9. A Year in the Life of a Contaminated Heater-Cooler Unit With Mycobacterium chimaera?

    PubMed

    Garvey, Mark I; Bradley, Craig W; Walker, Jimmy

    2017-06-01

    OBJECTIVE Heater-cooler units (HCUs) have been shown to be a source of Mycobacterium chimaera infections. For the past year, weekly water samples have been taken from HCUs used at University Hospitals Birmingham (UHB) NHS Foundation Trust. We report the microbial contamination of the HCUs over a year detailing the decontamination regimes applied at UHB to reduce the microbial load. DESIGN Observational study SETTING UHB is a tertiary referral teaching hospital in Birmingham, United Kingdom, that provides clinical services to nearly 1 million patients every year. The UHB Cardiac department is one of the largest in the United Kingdom and provides treatment for adult patients with a wide range of cardiac diseases. METHODS Water samples taken from HCUs used at UHB for cardiopulmonary bypass surgery were sampled over a year to determine the number of microorganisms by membrane filtration. Various decontamination processes were employed throughout the year. RESULTS Varying total viable counts containing a wide variety of microorganisms were obtained from water inside the HCUs. No M. chimaera were isolated after replacement of the HCU internal tubing. Stringent decontamination regimes resulted in degradation of the HCUs and increased TVCs after several months. CONCLUSION More work is required to ensure effective decontamination processes to reduce the microbial load within the HCUs. Our studies indicate that weekly water sampling for TVC will be required indefinitely to monitor the water quality in these units as well as regular replacement of the tubing to control the build-up of biofilm. Infect Control Hosp Epidemiol 2017;38:705-711.

  10. Microbial contamination in intraoral phosphor storage plates: the dilemma.

    PubMed

    de Souza, Tricia Murielly Pereira Andrade; de Castro, Ricardo Dias; de Vasconcelos, Laís César; Pontual, Andréa Dos Anjos; de Moraes Ramos Perez, Flávia Maria; Pontual, Maria Luiza Dos Anjos

    2017-01-01

    The aims of this study were to evaluate microbial contamination in phosphor storage plates in dental radiology services and discuss the possible origin of this contamination. The sample comprised 50 phosphor plates: 14 plates from service A, 30 from service B, and 6 in the control group, consisting of plates never used. Damp sterile swabs were rubbed on the phosphor plates, and then transferred to tests tubes containing sterile saline solution. Serial dilutions were made, and then inoculated in triplicate on Mueller Hinton agar plates and incubated at 37 °C/48 h, before counting the colony-forming units (CFU). The samples were also seeded in brain-heart infusion medium to confirm contamination by turbidity of the culture medium. All solutions, turbid and clean, were seeded in selective and non-selective media. At service A and B, 50 and 73.3 % of the phosphor plates were contaminated, respectively. This contamination was mainly due to bacteria of the genus Staphylococcus. CFU counts ranged from 26.4 to 80.0 CFU/plate. Most of the phosphor plates evaluated shown to be contaminated, mainly by Staphylococcus ssp. Quantitatively, this contamination occurred at low levels, possibly arising from handling of the plates. The use of a second plastic barrier may have diminished contamination by microorganisms from the oral cavity. There is a risk of cross-contamination by phosphor storage plates used in dental radiology services.

  11. Detection by denaturing gradient gel electrophoresis of ammonia-oxidizing bacteria in microcosms of crude oil-contaminated mangrove sediments.

    PubMed

    dos Santos, A C F; Marques, E L S; Gross, E; Souza, S S; Dias, J C T; Brendel, M; Rezende, R P

    2012-01-27

    Currently, the effect of crude oil on ammonia-oxidizing bacterium communities from mangrove sediments is little understood. We studied the diversity of ammonia-oxidizing bacteria in mangrove microcosm experiments using mangrove sediments contaminated with 0.1, 0.5, 1, 2, and 5% crude oil as well as non-contaminated control and landfarm soil from near an oil refinery in Camamu Bay in Bahia, Brazil. The evolution of CO(2) production in all crude oil-contaminated microcosms showed potential for mineralization. Cluster analysis of denaturing gradient gel electrophoresis-derived samples generated with primers for gene amoA, which encodes the functional enzyme ammonia monooxygenase, showed differences in the sample contaminated with 5% compared to the other samples. Principal component analysis showed divergence of the non-contaminated samples from the 5% crude oil-contaminated sediment. A Venn diagram generated from the banding pattern of PCR-denaturing gradient gel electrophoresis was used to look for operational taxonomic units (OTUs) in common. Eight OTUs were found in non-contaminated sediments and in samples contaminated with 0.5, 1, or 2% crude oil. A Jaccard similarity index of 50% was found for samples contaminated with 0.1, 0.5, 1, and 2% crude oil. This is the first study that focuses on the impact of crude oil on the ammonia-oxidizing bacterium community in mangrove sediments from Camamu Bay.

  12. A national outbreak of Salmonella serotype Tennessee infections from contaminated peanut butter: a new food vehicle for salmonellosis in the United States.

    PubMed

    Sheth, Anandi N; Hoekstra, Mike; Patel, Nehal; Ewald, Gwen; Lord, Cathy; Clarke, Carmen; Villamil, Elizabeth; Niksich, Katherine; Bopp, Cheryl; Nguyen, Thai-An; Zink, Donald; Lynch, Michael

    2011-08-01

    Salmonella serotype Tennessee is a rare cause of the estimated 1 million cases of salmonellosis occurring annually in the United States. In January 2007, we began investigating a nationwide increase in Salmonella Tennessee infections. We defined a case as Salmonella Tennessee infection in a patient whose isolate demonstrated 1 of 3 closely related pulsed-field gel electrophoresis patterns and whose illness began during the period 1 August 2006 through 31 July 2007. We conducted a case-control study in 22 states and performed laboratory testing of foods and environmental samples. We identified 715 cases in 48 states; 37% of isolates were from urine specimens. Illness was associated with consuming peanut butter more than once a week (matched odds ratio [mOR], 3.5 [95% confidence interval {95% CI}, 1.4-9.9]), consuming Brand X peanut butter (mOR, 12.1 [95% CI, 3.6-66.3]), and consuming Brand Y peanut butter (mOR, 9.1 [95% CI, 1.0-433]). Brands X and Y were produced in 1 plant, which ceased production and recalled products on 14 February 2007. Laboratories isolated outbreak strains of Salmonella Tennessee from 34 Brands X and Y peanut butter jars and 2 plant environmental samples. This large, widespread outbreak of salmonellosis is the first linked to peanut butter in the United States; a nationwide recall resulted in outbreak control. Environmental contamination in the peanut butter plant likely caused this outbreak. This outbreak highlights the risk of salmonellosis from heat-processed foods of nonanimal origin previously felt to be low risk for Salmonella contamination.

  13. Biomat development in soil treatment units for on-site wastewater treatment.

    PubMed

    Winstanley, H F; Fowler, A C

    2013-10-01

    We provide a simple mathematical model of the bioremediation of contaminated wastewater leaching into the subsoil below a septic tank percolation system. The model comprises a description of the percolation system's flows, together with equations describing the growth of biomass and the uptake of an organic contaminant concentration. By first rendering the model dimensionless, it can be partially solved, to provide simple insights into the processes which control the efficacy of the system. In particular, we provide quantitative insight into the effect of a near surface biomat on subsoil permeability; this can lead to trench ponding, and thus propagation of effluent further down the trench. Using the computed vadose zone flow field, the model can be simply extended to include reactive transport of other contaminants of interest.

  14. Evaluation of an Atmosphere Revitalization Subsystem for Deep Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Abney, Morgan B.; Conrad, Ruth E.; Frederick, Kenneth R.; Greenwood, Zachary W.; Kayatin, Matthew J.; Knox, James C.; Newton, Robert L.; Parrish, Keith J.; Takada, Kevin C.; hide

    2015-01-01

    An Atmosphere Revitalization Subsystem (ARS) suitable for deployment aboard deep space exploration mission vehicles has been developed and functionally demonstrated. This modified ARS process design architecture was derived from the International Space Station's (ISS) basic ARS. Primary functions considered in the architecture include trace contaminant control, carbon dioxide removal, carbon dioxide reduction, and oxygen generation. Candidate environmental monitoring instruments were also evaluated. The process architecture rearranges unit operations and employs equipment operational changes to reduce mass, simplify, and improve the functional performance for trace contaminant control, carbon dioxide removal, and oxygen generation. Results from integrated functional demonstration are summarized and compared to the performance observed during previous testing conducted on an ISS-like subsystem architecture and a similarly evolved process architecture. Considerations for further subsystem architecture and process technology development are discussed.

  15. Environmental Contaminants in Hospital Settings and Progress in Disinfecting Techniques

    PubMed Central

    Ceriale, Emma; Lenzi, Daniele; Burgassi, Sandra; Azzolini, Elena; Manzi, Pietro

    2013-01-01

    Medical devices, such as stethoscopes, and other objects found in hospital, such as computer keyboards and telephone handsets, may be reservoirs of bacteria for healthcare-associated infections. In this cross-over study involving an Italian teaching hospital we evaluated microbial contamination (total bacterial count (TBC) at 36°C/22°C, Staphylococcus spp., moulds, Enterococcus spp., Pseudomonas spp., E. coli, total coliform bacteria, Acinetobacter spp., and Clostridium difficile) of these devices before and after cleaning and differences in contamination between hospital units and between stethoscopes and keyboards plus handsets. We analysed 37 telephone handsets, 27 computer keyboards, and 35 stethoscopes, comparing their contamination in four hospital units. Wilcoxon signed-rank and Mann-Whitney tests were used. Before cleaning, many samples were positive for Staphylococcus spp. and coliforms. After cleaning, CFUs decreased to zero in most comparisons. The first aid unit had the highest and intensive care the lowest contamination (P < 0.01). Keyboards and handsets had higher TBC at 22°C (P = 0.046) and mould contamination (P = 0.002) than stethoscopes. Healthcare professionals should disinfect stethoscopes and other possible sources of bacterial healthcare-associated infections. The cleaning technique used was effective in reducing bacterial contamination. Units with high patient turnover, such as first aid, should practise stricter hygiene. PMID:24286078

  16. Post-Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada for Calendar Year 2016 (January 2016–December 2016), Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farnham, Irene

    Corrective Action Unit (CAU) 98: Frenchman Flat on the Nevada National Security Site was the location of 10 underground nuclear tests. CAU 98 underwent a series of investigations and actions in accordance with the Federal Facility Agreement and Consent Order to assess contamination of groundwater by radionuclides from the tests. A Closure Report completed that process in 2016 and called for long-term monitoring, use restrictions (URs), and institutional controls to protect the public and environment from potential exposure to contaminated groundwater. Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are evaluatedmore » to determine whether the UR boundaries remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Additionally, monitoring data are used to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries (CBs) calculated with the models are the primary basis of the UR boundaries. In summary, the monitoring results from 2016 indicate the regulatory controls on the closure of CAU 98 remain effective in protection of human health and the environment. Recommendations resulting from this first year of monitoring activities include formally incorporating wells UE-5 PW-1, UE-5 PW-2, and UE-5 PW-3 into the groundwater-level monitoring network given their strategic location in the basin; and early development of a basis for trigger levels for the groundwater-level monitoring given the observed trends. Additionally, it is recommended to improve the Real Estate/Operations Permit process for capturing information important for evaluating the impact of activities on groundwater resources, and to shift the reporting requirement for this annual report from the second quarter of the federal fiscal year (end of March) to the second quarter of the calendar year (end of June).« less

  17. Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

    NASA Technical Reports Server (NTRS)

    Roychoudhury, S.; Walsh, D.; Perry, J.

    2005-01-01

    An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

  18. Fumonisins affect the intestinal microbial homeostasis in broiler chickens, predisposing to necrotic enteritis.

    PubMed

    Antonissen, Gunther; Croubels, Siska; Pasmans, Frank; Ducatelle, Richard; Eeckhaut, Venessa; Devreese, Mathias; Verlinden, Marc; Haesebrouck, Freddy; Eeckhout, Mia; De Saeger, Sarah; Antlinger, Birgit; Novak, Barbara; Martel, An; Van Immerseel, Filip

    2015-09-23

    Fumonisins (FBs) are mycotoxins produced by Fusarium fungi. This study aimed to investigate the effect of these feed contaminants on the intestinal morphology and microbiota composition, and to evaluate whether FBs predispose broilers to necrotic enteritis. One-day-old broiler chicks were divided into a group fed a control diet, and a group fed a FBs contaminated diet (18.6 mg FB1+FB2/kg feed). A significant increase in the plasma sphinganine/sphingosine ratio in the FBs-treated group (0.21 ± 0.016) compared to the control (0.14 ± 0.014) indicated disturbance of the sphingolipid biosynthesis. Furthermore, villus height and crypt depth of the ileum was significantly reduced by FBs. Denaturing gradient gel electrophoresis showed a shift in the microbiota composition in the ileum in the FBs group compared to the control. A reduced presence of low-GC containing operational taxonomic units in ileal digesta of birds exposed to FBs was demonstrated, and identified as a reduced abundance of Candidatus Savagella and Lactobaccilus spp. Quantification of total Clostridium perfringens in these ileal samples, previous to experimental infection, using cpa gene (alpha toxin) quantification by qPCR showed an increase in C. perfringens in chickens fed a FBs contaminated diet compared to control (7.5 ± 0.30 versus 6.3 ± 0.24 log10 copies/g intestinal content). After C. perfringens challenge, a higher percentage of birds developed subclinical necrotic enteritis in the group fed a FBs contaminated diet as compared to the control (44.9 ± 2.22% versus 29.8 ± 5.46%).

  19. Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence

    PubMed Central

    2011-01-01

    Background Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD). Methods The study was carried out in 4 steps: i) patient room design, ii) CFD simulations of patient room design to model air flows throughout the patient room, adjacent anterooms and the corridor, iii) construction of a prototype room and subsequent experimental studies to characterize its performance iv) qualitative comparison of the tendencies between CFD prediction and experimental results. The Electricité De France (EDF) open-source software Code_Saturne® (http://www.code-saturne.org) was used and CFD simulations were conducted with an hexahedral mesh containing about 300 000 computational cells. The computational domain included the treatment room and two anterooms including equipment, staff and patient. Experiments with inert aerosol particles followed by time-resolved particle counting were conducted in the prototype room for comparison with the CFD observations. Results We found that thermal convection can create contaminated zones near the ceiling of the room, which can subsequently lead to contaminate transfer in adjacent rooms. Experimental confirmation of these phenomena agreed well with CFD predictions and showed that particles greater than one micron (i.e. bacterial or fungal spore sizes) can be influenced by these thermally induced flows. When the temperature difference between rooms was 7°C, a significant contamination transfer was observed to enter into the positive pressure room when the access door was opened, while 2°C had little effect. Based on these findings the constructed burn unit was outfitted with supplemental air exhaust ducts over the doors to compensate for the thermal convective flows. Conclusions CFD simulations proved to be a particularly useful tool for the design and optimization of a burn unit treatment room. Our results, which have been confirmed qualitatively by experimental investigation, stressed that airborne transfer of microbial size particles via thermal convection flows are able to bypass the protective overpressure in the patient room, which can represent a potential risk of cross contamination between rooms in protected environments. PMID:21371304

  20. Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence.

    PubMed

    Beauchêne, Christian; Laudinet, Nicolas; Choukri, Firas; Rousset, Jean-Luc; Benhamadouche, Sofiane; Larbre, Juliette; Chaouat, Marc; Benbunan, Marc; Mimoun, Maurice; Lajonchère, Jean-Patrick; Bergeron, Vance; Derouin, Francis

    2011-03-03

    Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD). The study was carried out in 4 steps: i) patient room design, ii) CFD simulations of patient room design to model air flows throughout the patient room, adjacent anterooms and the corridor, iii) construction of a prototype room and subsequent experimental studies to characterize its performance iv) qualitative comparison of the tendencies between CFD prediction and experimental results. The Electricité De France (EDF) open-source software Code_Saturne® (http://www.code-saturne.org) was used and CFD simulations were conducted with an hexahedral mesh containing about 300 000 computational cells. The computational domain included the treatment room and two anterooms including equipment, staff and patient. Experiments with inert aerosol particles followed by time-resolved particle counting were conducted in the prototype room for comparison with the CFD observations. We found that thermal convection can create contaminated zones near the ceiling of the room, which can subsequently lead to contaminate transfer in adjacent rooms. Experimental confirmation of these phenomena agreed well with CFD predictions and showed that particles greater than one micron (i.e. bacterial or fungal spore sizes) can be influenced by these thermally induced flows. When the temperature difference between rooms was 7°C, a significant contamination transfer was observed to enter into the positive pressure room when the access door was opened, while 2°C had little effect. Based on these findings the constructed burn unit was outfitted with supplemental air exhaust ducts over the doors to compensate for the thermal convective flows. CFD simulations proved to be a particularly useful tool for the design and optimization of a burn unit treatment room. Our results, which have been confirmed qualitatively by experimental investigation, stressed that airborne transfer of microbial size particles via thermal convection flows are able to bypass the protective overpressure in the patient room, which can represent a potential risk of cross contamination between rooms in protected environments.

  1. Clinical studies of the High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS), for continuous disinfection in the burn unit inpatient and outpatient settings.

    PubMed

    Bache, Sarah E; Maclean, Michelle; MacGregor, Scott J; Anderson, John G; Gettinby, George; Coia, John E; Taggart, Ian

    2012-02-01

    Infections are the leading cause of morbidity and mortality in burn patients and prevention of contamination from exogenous sources including the hospital environment is becoming increasingly emphasised. The High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS) is bactericidal yet safe for humans, allowing continuous disinfection of the environment surrounding burn patients. Environmental samples were collected from inpatient isolation rooms and the outpatient clinic in the burn unit, and comparisons were then made between the bacterial contamination levels observed with and without use of the HINS-light EDS. Over 1000 samples were taken. Inpatient studies, with sampling carried out at 0800 h, demonstrated a significant reduction in the average number of bacterial colonies following HINS-light EDS use of between 27% and 75%, (p<0.05). There was more variation when samples were taken at times of increased activity in the room. Outpatient studies during clinics demonstrated a 61% efficacy in the reduction of bacterial contamination on surfaces throughout the room during the course of a clinic (p=0.02). The results demonstrate that use of the HINS-light EDS allows efficacious bacterial reductions over and above that achieved by standard cleaning and infection control measures in both inpatient and outpatient settings in the burn unit. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  2. Gas Tungsten Arc Welding and Plasma Arc Cutting. Teacher Edition.

    ERIC Educational Resources Information Center

    Fortney, Clarence; And Others

    This welding curriculum guide treats two topics in detail: the care of tungsten electrodes and the entire concept of contamination control and the hafnium electrode and its importance in dual-air cutting systems that use compressed shop air for plasma arc cutting activities. The guide contains three units of instruction that cover the following…

  3. RNAi-mediated control of aflatoxins in peanut: Method to analyze mycotoxin production and transgene expression in the peanut/Aspergillus pathosystem

    USDA-ARS?s Scientific Manuscript database

    The Food and Agriculture Organization of the United Nations estimates that 25% of the food crops in the world are contaminated with aflatoxins. That represents 100 million tons of food being destroyed or diverted to non-human consumption each year. Aflatoxins are powerful carcinogens normally accu...

  4. Quality Assurance and Quality Control, Part 2.

    PubMed

    Akers, Michael J

    2015-01-01

    The tragedy surrounding the New England Compounding Center and contaminated steroid syringe preparations clearly points out what can happen if quality-assurance and quality-control procedures are not strictly practiced in the compounding of sterile preparations. This article is part 2 of a two-part article on requirements to comply with United States Pharmacopeia general chapters <797> and <1163> with respect to quality assurance of compounded sterile preparations. Part 1 covered documentation requirements, inspection procedures, compounding accuracy checks, and part of a discussion on bacterial endotoxin testing. Part 2 covers sterility testing, the completion from part 1 on bacterial endotoxin testing, a brief dicussion of United States Pharmacopeia <1163>, and advances in pharmaceutical quality systems.

  5. Technical Requirements for On-Site Thermal Desorption of Solid Media Contaminated with Hazardous Chlorinated Organics

    DTIC Science & Technology

    1997-09-18

    scrubbers , detectable dioxin/furans may occur, since dioxin/furans are much more soluble in organics than in water. Carbon adsorption is frequently...air pollution control device is required. Acid gases may be controlled by using a wet or dry scrubber or by using a coated baghouse. Operating...unit: 1. exit treated waste temperature; 2. baghouse pressure drop, venturi pressure drop, or drop in liquid/gas ratio; 3. waste feed rate; 4

  6. Installation Restoration Program Phase 2. Confirmation/Quantification. Stage 2. Volume 2. Tyndall Air Force Base, Florida

    DTIC Science & Technology

    1988-08-01

    control data (lat tarK., lab spikes, and lab duplicates) in the report , as well as field quality control data. j. For those metiods which employ gas ...FORCE BASE, TEXAS 78235-5501 NOTICE This report has been prepared for the United States Air Force by Environmental Science and Engineering , Inc. (ESE...testing, field sampling, contamination assessment report preparation, and recommendations for remedial actions. U.S. Army Toxic and Hazardous Materials

  7. Phase I Flow and Transport Model Document for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada, Revision 1 with ROTCs 1 and 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, Robert

    The Underground Test Area (UGTA) Corrective Action Unit (CAU) 97, Yucca Flat/Climax Mine, in the northeast part of the Nevada National Security Site (NNSS) requires environmental corrective action activities to assess contamination resulting from underground nuclear testing. These activities are necessary to comply with the UGTA corrective action strategy (referred to as the UGTA strategy). The corrective action investigation phase of the UGTA strategy requires the development of groundwater flow and contaminant transport models whose purpose is to identify the lateral and vertical extent of contaminant migration over the next 1,000 years. In particular, the goal is to calculate themore » contaminant boundary, which is defined as a probabilistic model-forecast perimeter and a lower hydrostratigraphic unit (HSU) boundary that delineate the possible extent of radionuclide-contaminated groundwater from underground nuclear testing. Because of structural uncertainty in the contaminant boundary, a range of potential contaminant boundaries was forecast, resulting in an ensemble of contaminant boundaries. The contaminant boundary extent is determined by the volume of groundwater that has at least a 5 percent chance of exceeding the radiological standards of the Safe Drinking Water Act (SDWA) (CFR, 2012).« less

  8. [Recent advance in solidification/stabilization technology for the remediation of heavy metals-contaminated soil].

    PubMed

    Hao, Han-zhou; Chen, Tong-bin; Jin, Meng-gui; Lei, Mei; Liu, Cheng-wu; Zu, Wen-pu; Huang, Li-mi

    2011-03-01

    Remediation of heavy metals-contaminated soil is still a difficulty and a hotspot of international research projects. At present, the technologies commonly adopted for the remediation of contaminated sites mainly include excavation, solidification/stabilization (S/S), soil washing, soil vapor extraction (SVE), thermal treatment, and bioremediation. Based on the S/S technical guidelines of Unite State Environmental Protection Agency (EPA) and United Kingdom Environment Agency (EA) and the domestic and foreign patents, this paper introduced the concepts of S/S and its development status at home and abroad, and discussed its future development directions. Solidification refers to a process that binds contaminated media with a reagent, changing the media's physical properties via increasing its compressive strength, decreasing its permeability, and encapsulating the contaminants to form a solid material. Stabilization refers to the process that involves a chemical reaction which reduces the leachability of a waste, chemically immobilizes the waste and reduces its solubility, making the waste become less harmful or less mobile. S/S technology includes cement solidification, lime pozzolanic solidification, plastic materials stabilization, vitrification, and regent-based stabilization. Stabilization (or immobilization) treatment processes convert contaminants to less mobile forms through chemical or thermal interactions. In stabilization technology, the aim of adding agents is to change the soil physical and chemical properties through pH control technology, redox potential technology, precipitation techniques, adsorption technology, and ion-exchange technology that change the existing forms of heavy metals in soil, and thus, reduce the heavy metals bioavailability and mobility. This review also discussed the S/S evaluation methods, highlighted the need to enhance S/S technology in the molecular bonding, soil polymers, and formulation of China's S/S technical guidelines.

  9. Efficacy Evaluation of a non-contact automatic articulating paper dispenser in controlling articulating paper microbial contamination

    PubMed Central

    Li, Yajin; Chen, Litong; Yuan, Fusong; Li, Yugui; Zhou, Yongsheng; Sun, Yuchun

    2017-01-01

    This study is to quantitatively evaluate the efficacy of using a non-contact automatic articulating paper dispenser for reducing microbial articulating paper contamination. Articulating papers in four-handed mode, non-four-handed mode, and via an automatic articulating paper dispenser were evaluated. An adenosine triphosphate bioluminescence assay was used to quantitatively measure the relative light unit (RLU) values of the rest unused articulating papers in the same package to detect contamination at 4 time points, and triplicate examinations were performed for all three methods. The RLUs were recorded, compared, and evaluated. For four-handed mode (n = 36), the RLUs at the four time points were 2.44, 32.89, 37.89, and 27.22, with a satisfactory rate of 94%. The RLUs for non-four-handed mode (n = 36) were 2.22, 286.44, 299.44, and 493.56, with a satisfactory rate of 36%. The RLUs for using the automatic dispenser (n = 36) were all 0 with a satisfactory rate of 100%. The satisfactory rates were significantly different among three methods. No significant differences were observed in the satisfactory rates for the four time points samples. Contact by gloved hands can cause severe biological contamination of articulating paper. However, by using standard four-handed mode or a non-contact automatic articulating paper dispenser, contamination can be controlled. PMID:28466846

  10. Mycobacterium chimaera and cardiac surgery.

    PubMed

    Stewardson, Andrew J; Stuart, Rhonda L; Cheng, Allen C; Johnson, Paul Dr

    2017-02-20

    There is an ongoing investigation into infections with non-tuberculous mycobacteria associated with contaminated heater-cooler units used in cardiac surgery. The overall risk is low, but surgical site and disseminated infections have been reported, including one possible case in Australia, mainly with surgery involving implantation of prosthetic material. Mycobacterium chimaera infection should be considered in patients who have previously undergone surgery with cardiopulmonary bypass and who present with cardiac or disseminated infection or sternal wound infection unresponsive to standard antibiotic therapy. Where cases are suspected, patients should be investigated and managed in consultation with an infectious diseases physician and/or clinical microbiologist. If cases are confirmed or heater-cooler devices are found to be contaminated, details should be reported to the hospital infection control team, the jurisdictional health department, the Therapeutic Goods Administration and the Australian distributor of the affected heater-cooler unit(s). Measures to manage risk should include communicating with relevant hospital departments, ensuring that the manufacturer's updated instructions for use are followed, regular testing of machines, and reviewing the location of machines when in use.

  11. Hygiene intervention reduces contamination of weaning food in Bangladesh.

    PubMed

    Islam, Mohammad Sirajul; Mahmud, Zahid Hayat; Gope, Partha Sarathi; Zaman, Rokon Uz; Hossain, Zakir; Islam, Mohammad Shafiqul; Mondal, Dinesh; Sharker, Mohammad Abu Yushuf; Islam, Khairul; Jahan, Hasin; Bhuiya, Abbas; Endtz, Hubert P; Cravioto, Alejandro; Curtis, Valerie; Touré, Ousmane; Cairncross, Sandy

    2013-03-01

    This study was conducted to measure the impact of a hygiene intervention on the contamination of weaning food in Bangladesh. Sixty households were selected: 30 study and 30 control households. Samples of weaning food were collected from all the 60 households at baseline and examined for faecal coliforms (FC), faecal streptococci (FS) and Clostridium perfringens (CP) following standard procedures. After cooking, food samples were collected on three occasions before feeding. Following Hazard Analysis Critical Control Point (HACCP) procedures, critical control points were determined. The mothers in the 30 study households were then trained for 4 weeks in how to attain the control point conditions. Then, again the food samples were collected and analysed. At baseline, weaning foods from study and control households were heavily contaminated with FC and FS. The FC and FS counts were 1.84 log(10) and 1.92 log(10) colony-forming unit (cfu)/g, respectively, in the study households, and 0.86 log(10) and 1.33 log(10)  cfu/g, respectively, in the control households in the first feeding. After the intervention, the FC and FS counts in study households had dropped to 0.10 log(10) and 0.09 log(10)  cfu/g, respectively, a statistically significant reduction (P < 0.001). Monitoring the sustainability of the behaviour change after 3 months showed that the mothers were maintaining food hygiene. A hygiene intervention following the HACCP approach reduced the weaning food contamination significantly. Awareness building among mothers about weaning food hygiene could be an important intervention for preventing weaning food-related diarrhoea in Bangladesh. © 2012 Blackwell Publishing Ltd.

  12. RNAi-mediated Control of Aflatoxins in Peanut: Method to Analyze Mycotoxin Production and Transgene Expression in the Peanut/Aspergillus Pathosystem

    PubMed Central

    Arias, Renée S.; Dang, Phat M.; Sobolev, Victor S.

    2015-01-01

    The Food and Agriculture Organization of the United Nations estimates that 25% of the food crops in the world are contaminated with aflatoxins. That represents 100 million tons of food being destroyed or diverted to non-human consumption each year. Aflatoxins are powerful carcinogens normally accumulated by the fungi Aspergillus flavus and A. parasiticus in cereals, nuts, root crops and other agricultural products. Silencing of five aflatoxin-synthesis genes by RNA interference (RNAi) in peanut plants was used to control aflatoxin accumulation following inoculation with A. flavus. Previously, no method existed to analyze the effectiveness of RNAi in individual peanut transgenic events, as these usually produce few seeds, and traditional methods of large field experiments under aflatoxin-conducive conditions were not an option. In the field, the probability of finding naturally contaminated seeds is often 1/100 to 1/1,000. In addition, aflatoxin contamination is not uniformly distributed. Our method uses few seeds per transgenic event, with small pieces processed for real-time PCR (RT-PCR) or small RNA sequencing, and for analysis of aflatoxin accumulation by ultra-performance liquid chromatography (UPLC). RNAi-expressing peanut lines 288-72 and 288-74, showed up to 100% reduction (p≤0.01) in aflatoxin B1 and B2 compared to the control that accumulated up to 14,000 ng.g-1 of aflatoxin B1 when inoculated with aflatoxigenic A. flavus. As reference, the maximum total of aflatoxins allowable for human consumption in the United States is 20 ng.g-1. This protocol describes the application of RNAi-mediated control of aflatoxins in transgenic peanut seeds and methods for its evaluation. We believe that its application in breeding of peanut and other crops will bring rapid advancement in this important area of science, medicine and human nutrition, and will significantly contribute to the international effort to control aflatoxins, and potentially other mycotoxins in major food crops. PMID:26709851

  13. RNAi-mediated Control of Aflatoxins in Peanut: Method to Analyze Mycotoxin Production and Transgene Expression in the Peanut/Aspergillus Pathosystem.

    PubMed

    Arias, Renée S; Dang, Phat M; Sobolev, Victor S

    2015-12-21

    The Food and Agriculture Organization of the United Nations estimates that 25% of the food crops in the world are contaminated with aflatoxins. That represents 100 million tons of food being destroyed or diverted to non-human consumption each year. Aflatoxins are powerful carcinogens normally accumulated by the fungi Aspergillus flavus and A. parasiticus in cereals, nuts, root crops and other agricultural products. Silencing of five aflatoxin-synthesis genes by RNA interference (RNAi) in peanut plants was used to control aflatoxin accumulation following inoculation with A. flavus. Previously, no method existed to analyze the effectiveness of RNAi in individual peanut transgenic events, as these usually produce few seeds, and traditional methods of large field experiments under aflatoxin-conducive conditions were not an option. In the field, the probability of finding naturally contaminated seeds is often 1/100 to 1/1,000. In addition, aflatoxin contamination is not uniformly distributed. Our method uses few seeds per transgenic event, with small pieces processed for real-time PCR (RT-PCR) or small RNA sequencing, and for analysis of aflatoxin accumulation by ultra-performance liquid chromatography (UPLC). RNAi-expressing peanut lines 288-72 and 288-74, showed up to 100% reduction (p ≤ 0.01) in aflatoxin B1 and B2 compared to the control that accumulated up to 14,000 ng · g(-1) of aflatoxin B1 when inoculated with aflatoxigenic A. flavus. As reference, the maximum total of aflatoxins allowable for human consumption in the United States is 20 ng · g(-1). This protocol describes the application of RNAi-mediated control of aflatoxins in transgenic peanut seeds and methods for its evaluation. We believe that its application in breeding of peanut and other crops will bring rapid advancement in this important area of science, medicine and human nutrition, and will significantly contribute to the international effort to control aflatoxins, and potentially other mycotoxins in major food crops.

  14. Overview of the US EPA/SERDP/ESTCP: Laboratory, Field ...

    EPA Pesticide Factsheets

    Passive sampling can be used for applications at contaminated sediment sites including performing assessments of contaminant bioavailability (i.e., freely dissolved concentration (Cfree)), conducting remedial investigations and feasibility studies, and assessing the potential for contaminant bioaccumulation. Previous research articles and documents have discussed many aspects of passive sampling however no definitive guidance on the laboratory, field and analytical procedures for using passive sampling at contaminated sediment sites has been provided. The document discussed in this presentation provides passive sampler users with the guidance necessary to apply the technology to evaluate contaminated sediments. Contaminants discussed include polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and the metals, cadmium, copper, nickel, lead and zinc. The document is divided into sections including discussions of different types of samplers used commonly in the United States, the selection and use of performance reference compounds (PRCs), the extraction and instrumental analysis of passive samplers, data analysis and quality assurance/quality control, and a list of passive sampling related references. The document is not intended to serve as a series of standard operating procedures (SOPs) but rather seeks to provide users with the information needed to develop their own SOPs. The document also includes the names of selected passive sam

  15. Chemistry experience in the primary heat transport circuits of Kraftwerk Union pressurized water reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riess, R.

    Chosen for this description of the selected Kraftwerk Union (KWU) pressurized water reactor units were Obrigheim (KWO, 345 MW(e)), Stade (KKS, 662 (MW(e)), Borselle (KCB, 477 MW(e)), and Biblis (KWB-A, 1204 MW(e)). The experience at these plants shows that with a special startup procedure and a proper chemical control of the primary heat transport system that influences general corrosion, selective types of corrosion, corrosion product activity transport and resulting contamination, and radiation-induced decomposition, KWU units have no basic problems.

  16. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    PubMed

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces cannot be adequately disinfected without disassembly, which is costly in time, staff and resources. The automated STCS DCU suction disinfection system used with single component handpieces provides an effective solution. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Second LDEF Post-Retrieval Symposium interim results of experiment A0034

    NASA Technical Reports Server (NTRS)

    Linton, Roger C.; Kamenetzky, Rachel R.

    1993-01-01

    Thermal control coatings and contaminant collector mirrors were exposed on the leading and trailing edge modules of Long Duration Exposure Facility (LDEF) experiment A0034 to provide a basis of comparison for investigating the role of atomic oxygen in the stimulation of volatile outgassing products. The exposure of identical thermal coatings on both the leading and trailing edges of the LDEF and the additional modified exposure of identical coatings under glass windows and metallic covers in each of the flight modules provided multiple combinations of space environmental exposure to the coatings and the contaminant collector mirrors. Investigations were made to evaluate the effects of the natural space and the induced environments on the thermal coatings and the collector mirrors to differentiate the sources of observed material degradation. Two identical flight units were fabricated for the LDEF mission, each of which included twenty-five thermal control coatings mounted in isolated compartments, each with an adjacent contaminant collector mirror mounted on the wall. The covers of the flight units included apertures for each compartment, exposing the thermal coatings directly to the space environment. Six of these compartments were sealed with ultraviolet-grade transmitting quartz windows and four other compartments were sealed with aluminum covers. One module of this passive LDEF experiment, occupying one-sixth of a full tray, was mounted in Tray C9 (leading edge), while the other identical module was mounted in Tray C3 (trailing edge).

  18. RCT: Module 2.11, Radiological Work Coverage, Course 8777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    2017-07-20

    Radiological work is usually approved and controlled by radiation protection personnel by using administrative and procedural controls, such as radiological work permits (RWPs). In addition, some jobs will require working in, or will have the potential for creating, very high radiation, contamination, or airborne radioactivity areas. Radiological control technicians (RCTs) providing job coverage have an integral role in controlling radiological hazards. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  19. Design of a microbial contamination detector and analysis of error sources in its optical path.

    PubMed

    Zhang, Chao; Yu, Xiang; Liu, Xingju; Zhang, Lei

    2014-05-01

    Microbial contamination is a growing concern in the food safety today. To effectively control the types and degree of microbial contamination during food production, this paper introduces a design for a microbial contamination detector that can be used for quick in-situ examination. The designed detector can identify the category of microbial contamination by locating its characteristic absorption peak and then can calculate the concentration of the microbial contamination by fitting the absorbance vs. concentration lines of standard samples with gradient concentrations. Based on traditional scanning grating detection system, this design improves the light splitting unit to expand the scanning range and enhance the accuracy of output wavelength. The motor rotation angle φ is designed to have a linear relationship with the output wavelength angle λ, which simplifies the conversion of output spectral curves into wavelength vs. light intensity curves. In this study, we also derive the relationship between the device's major sources of errors and cumulative error of the output wavelengths, and suggest a simple correction for these errors. The proposed design was applied to test pigments and volatile basic nitrogen (VBN) which evaluated microbial contamination degrees of meats, and the deviations between the measured values and the pre-set values were only in a low range of 1.15% - 1.27%.

  20. An Induced Environment Contamination Monitor for the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Miller, E. R. (Editor); Decher, R. (Editor)

    1978-01-01

    The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

  1. Biofilm formation in an experimental water distribution system: the contamination of non-touch sensor taps and the implication for healthcare.

    PubMed

    Moore, Ginny; Stevenson, David; Thompson, Katy-Anne; Parks, Simon; Ngabo, Didier; Bennett, Allan M; Walker, Jimmy T

    2015-01-01

    Hospital tap water is a recognised source of Pseudomonas aeruginosa. U.K. guidance documents recommend measures to control/minimise the risk of P. aeruginosa in augmented care units but these are based on limited scientific evidence. An experimental water distribution system was designed to investigate colonisation of hospital tap components. P. aeruginosa was injected into 27 individual tap 'assemblies'. Taps were subsequently flushed twice daily and contamination levels monitored over two years. Tap assemblies were systematically dismantled and assessed microbiologically and the effect of removing potentially contaminated components was determined. P. aeruginosa was repeatedly recovered from the tap water at levels above the augmented care alert level. The organism was recovered from all dismantled solenoid valves with colonisation of the ethylene propylene diene monomer (EPDM) diaphragm confirmed by microscopy. Removing the solenoid valves reduced P. aeruginosa counts in the water to below detectable levels. This effect was immediate and sustained, implicating the solenoid diaphragm as the primary contamination source.

  2. Fermented whey as poultry feed additive to prevent fungal contamination.

    PubMed

    Londero, Alejandra; León Peláez, María A; Diosma, Gabriela; De Antoni, Graciela L; Abraham, Analía G; Garrote, Graciela L

    2014-12-01

    Fungal contamination of poultry feed causes economic losses to industry and represents a potential risk to animal health. The aim of the present study was to analyze the effectiveness of whey fermented with kefir grains as additive to reduce fungal incidence, thus improving feed safety. Whey fermented for 24 h at 20 °C with kefir grains (100 g L(-1) ) reduced conidial germination of Aspergillus flavus, Aspergillus parasiticus, Aspergillus terreus, Aspergillus fumigatus, Penicillium crustosum, Trichoderma longibrachiatum and Rhizopus sp. Poultry feed supplemented with fermented whey (1 L kg(-1) ) was two to four times more resistant to fungal contamination than control feed depending on the fungal species. Additionally, it contained kefir microorganisms at levels of 1 × 10(8) colony-forming units (CFU) kg(-1) of lactic acid bacteria and 6 × 10(7) CFU kg(-1) of yeasts even after 30 days of storage. Fermented whey added to poultry feed acted as a biopreservative, improving its resistance to fungal contamination and increasing its shelf life. © 2014 Society of Chemical Industry.

  3. Biological Control of Aflatoxin Contamination in U.S. Crops and the Use of Bioplastic Formulations of Aspergillus flavus Biocontrol Strains To Optimize Application Strategies.

    PubMed

    Abbas, Hamed K; Accinelli, Cesare; Shier, W Thomas

    2017-08-23

    Aflatoxin contamination has a major economic impact on crop production in the southern United States. Reduction of aflatoxin contamination in harvested crops has been achieved by applying nonaflatoxigenic biocontrol Aspergillus flavus strains that can out-compete wild aflatoxigenic A. flavus, reducing their numbers at the site of application. Currently, the standard method for applying biocontrol A. flavus strains to soil is using a nutrient-supplying carrier (e.g., pearled barley for Afla-Guard). Granules of Bioplastic (partially acetylated corn starch) have been investigated as an alternative nutritive carrier for biocontrol agents. Bioplastic granules have also been used to prepare a sprayable biocontrol formulation that gives effective reduction of aflatoxin contamination in harvested corn kernels with application of much smaller amounts to leaves later in the growing season. The ultimate goal of biocontrol research is to produce biocontrol systems that can be applied to crops only when long-range weather forecasting indicates they will be needed.

  4. Space Stirling Cryocooler Contamination Lessons Learned and Recommended Control Procedures

    NASA Astrophysics Data System (ADS)

    Glaister, D. S.; Price, K.; Gully, W.; Castles, S.; Reilly, J.

    The most important characteristic of a space cryocooler is its reliability over a lifetime typically in excess of 7 years. While design improvements have reduced the probability of mechanical failure, the risk of internal contamination is still significant and has not been addressed in a consistent approach across the industry. A significant fraction of the endurance test and flight units have experienced some performance degradation related to internal contamination. The purpose of this paper is to describe and assess the contamination issues inside long life, space cryocoolers and to recommend procedures to minimize the probability of encountering contamination related failures and degradation. The paper covers the sources of contamination, the degradation and failure mechanisms, the theoretical and observed cryocooler sensitivity, and the recommended prevention procedures and their impact. We begin with a discussion of the contamination sources, both artificial and intrinsic. Next, the degradation and failure mechanisms are discussed in an attempt to arrive at a contaminant susceptibility, from which we can derive a contamination budget for the machine. This theoretical sensitivity is then compared with the observed sensitivity to illustrate the conservative nature of the assumed scenarios. A number of lessons learned on Raytheon, Ball, Air Force Research Laboratory, and NASA GSFC programs are shared to convey the practical aspects of the contamination problem. Then, the materials and processes required to meet the proposed budget are outlined. An attempt is made to present a survey of processes across industry.

  5. Large-eddy simulation of human-induced contaminant transport in room compartments.

    PubMed

    Choi, J-I; Edwards, J R

    2012-02-01

    A large-eddy simulation is used to investigate contaminant transport owing to complex human and door motions and vent-system activity in room compartments where a contaminated and clean room are connected by a vestibule. Human and door motions are simulated with an immersed boundary procedure. We demonstrate the details of contaminant transport owing to human- and door-motion-induced wake development during a short-duration event involving the movement of a person (or persons) from a contaminated room, through a vestibule, into a clean room. Parametric studies that capture the effects of human walking pattern, door operation, over-pressure level, and vestibule size are systematically conducted. A faster walking speed results in less mass transport from the contaminated room into the clean room. The net effect of increasing the volume of the vestibule is to reduce the contaminant transport. The results show that swinging-door motion is the dominant transport mechanism and that human-induced wake motion enhances compartment-to-compartment transport. The effect of human activity on contaminant transport may be important in design and operation of clean or isolation rooms in chemical or pharmaceutical industries and intensive care units for airborne infectious disease control in a hospital. The present simulations demonstrate details of contaminant transport in such indoor environments during human motion events and show that simulation-based sensitivity analysis can be utilized for the diagnosis of contaminant infiltration and for better environmental protection. © 2011 John Wiley & Sons A/S.

  6. Vancomycin-Resistant Enterococci (VRE) in The Intensive Care Unit in a Nonoutbreak Setting: Identification of Potential Reservoirs and Epidemiological Associations Between Patient and Environmental VRE.

    PubMed

    McDermott, Hélène; Skally, Mairead; O'Rourke, James; Humphreys, Hilary; Fitzgerald-Hughes, Deirdre

    2018-01-01

    OBJECTIVE Among nosocomial bloodstream infections caused by enterococcal species, Ireland has the highest proportion caused by vancomycin-resistant enterococci (VRE) in Europe at 45.8%. The contribution of the near-patient environment to VRE transmission outside of outbreaks was investigated. DESIGN A prospective observational study was conducted during 7 sampling periods. METHODS Recovery of VRE isolates by swabbing the near-patient environment and patients in the intensive care unit (ICU) was conducted to identify reservoirs, clinical and molecular epidemiological associations, and the success of active surveillance cultures (ASCs). RESULTS Of 289 sampling occasions involving 157 patients and their bed spaces, VRE isolates were recovered from patient bed spaces, clinical samples, or both on 114 of 289 sampling occasions (39.4%). The patient and their bed space were positive for VRE on 34 of 114 VRE-associated sampling occasions (29.8%). Of 1,647 environment samples, 107 sites (6.5%) were VRE positive, with significantly greater VRE recovery from isolation rooms than from the open-plan area (9.1% vs 4.1%; P < .0001). The most frequently VRE-contaminated sites were the drip stand, bed control panel, and chart holders, which together accounted for 61% of contaminated sites. The use of ASCs resulted in a 172% increase in identification of VRE-colonized patients. Molecular typing revealed 2 environmental clusters, 1 cluster involving 3 patients and generally greater heterogeneity of patient isolates compared to environmental isolates. CONCLUSION Even outside of outbreaks, near-patient ICU environmental contamination with VRE is common. Better infection control policies that limit environmental transmission of VRE in the ICU and that are supported by molecular epidemiological studies, in real time, are needed. Infect Control Hosp Epidemiol 2018;39:40-45.

  7. Direct-field acoustic testing of a flight system : logistics, challenges, and results.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stasiunas, Eric Carl; Gurule, David Joseph; Babuska, Vit

    2010-10-01

    Before a spacecraft can be considered for launch, it must first survive environmental testing that simulates the launch environment. Typically, these simulations include vibration testing performed using an electro-dynamic shaker. For some spacecraft however, acoustic excitation may provide a more severe loading environment than base shaker excitation. Because this was the case for a Sandia Flight System, it was necessary to perform an acoustic test prior to launch in order to verify survival due to an acoustic environment. Typically, acoustic tests are performed in acoustic chambers, but because of scheduling, transportation, and cleanliness concerns, this was not possible. Instead, themore » test was performed as a direct field acoustic test (DFAT). This type of test consists of surrounding a test article with a wall of speakers and controlling the acoustic input using control microphones placed around the test item, with a closed-loop control system. Obtaining the desired acoustic input environment - proto-flight random noise input with an overall sound pressure level (OASPL) of 146.7 dB-with this technique presented a challenge due to several factors. An acoustic profile with this high OASPL had not knowingly been obtained using the DFAT technique prior to this test. In addition, the test was performed in a high-bay, where floor space and existing equipment constrained the speaker circle diameter. And finally, the Flight System had to be tested without contamination of the unit, which required a contamination bag enclosure of the test unit. This paper describes in detail the logistics, challenges, and results encountered while performing a high-OASPL, direct-field acoustic test on a contamination-sensitive Flight System in a high-bay environment.« less

  8. Indices of benthic community tolerance in contaminated Great Lakes sediments: Relations with sediment contaminant concentrations, sediment toxicity, and the sediment quality triad

    USGS Publications Warehouse

    Wildhaber, M.L.; Schmitt, C.J.

    1998-01-01

    We evaluated the toxic-units model developed by Wildhaber and Schmitt (1996) as a predictor of indices of mean tolerance to pollution (i.e., Lenat, 1993; Hilsenhoff, 1987) and other benthic community indices from Great Lakes sediments containing complex mixtures of environmental contaminants (e.g., polychlorinated biphenyls – PCBs, polycyclic aromatic hydrocarbons – PAHs, pesticides, chlorinated dioxins, and metals). Sediment toxic units were defined as the ratio of the estimated pore-water concentration of a contaminant to its chronic toxicity as estimated by U.S. Environmental Protection Agency Ambient Water Quality Criteria (AWQC) or other applicable standard. The total hazard of a sediment to aquatic life was assessed by summing toxic units for all contaminants quantified. Among the benthic community metrics evaluated, total toxic units were most closely correlated with Lenat's (1993) and Hilsenhoff's (1987) indices of community tolerance (TL and TH, respectively); toxic units accounted for 42% TL and 53% TH of variability in community tolerance as measured by Ponar grabs. In contrast, taxonomic richness and Shannon-Wiener diversity were not correlated (P > 0.05) with toxic units. Substitution of order- or family-level identifications for lowest possible (mostly genus- or species-) level identifications in the calculation of TL and TH indices weakened the relationships with toxic units. Tolerance values based on order- and family-level identifications of benthos for artificial substrate samples were more strongly correlated with toxic units than tolerance values for benthos from Ponar grabs. The ability of the toxic-units model to predict the other two components (i.e., laboratory-measured sediment toxicity and benthic community composition) of the Sediment Quality Triad (SQT) may obviate the need for the SQT in some situations.

  9. Development of Multiplex Real-time PCR with Internal Amplification Control for Simultaneous Detection of Salmonella and Cronobacter sakazakii in Powdered Infant Formula.

    USDA-ARS?s Scientific Manuscript database

    Contamination of powdered infant formula (PIF) by the bacteria Cronobacter sakazakii and Salmonella enterica was deemed a matter of great concern by the World Health Organization and the Food and Agriculture Organization of the United Nations in 2004. Therefore, we developed a rapid and sensitive m...

  10. Response to Alert on Possible Infections with Mycobacterium chimaera From Contaminated Heater-Cooler Devices in Hospitals Participating in the Canadian Nosocomial Infection Surveillance Program (CNISP).

    PubMed

    Mertz, Dominik; Macri, Jennifer; Hota, Susy; Amaratunga, Kanchana; Davis, Ian; Johnston, Lynn; Lee, Bonita; Pelude, Linda; Science, Michelle; Smith, Stephanie; Wong, Alice

    2018-04-01

    Canadian hospitals were made aware of the risk of Mycobacterium chimaera infection associated with heater-cooler units (HCUs) through alerts issued by the US food and Drug Administration (FDA) and the US Centers for Disease Control and Prevention (CDC). In response, most hospitals conducted retrospective reviews for infections, informed exposed patients, and initiated a requirement for informed consent with HCU use. Infect Control Hosp Epidemiol 2018;39:482-484.

  11. Tungsten insulated susceptor cup for high temperature induction furnace eliminates contamination

    NASA Technical Reports Server (NTRS)

    Geringer, H. J.

    1966-01-01

    METILUR /Materials Experimental Tungsten Induction Laboratory Unit Replacement/ is an improved, unitized design of a susceptor cup and shielding that uses only one type of construction material /tungsten/ which eliminates contamination. Cycling runs can be accomplished with METILUR.

  12. Prevention of microbial contamination of the dental unit caused by suction into the turbine drive air lines.

    PubMed

    Ojajärvi, J

    1996-01-01

    To determine whether a specially designed antisuction device can prevent the bacterial contamination of the drive air lines of the dental turbine that is caused by suction when the turbine is stopped. A dental unit with and without the antisuction device and three different types of sterilized handpieces were used in the tests. Each turbine was operated in air, then submerged into a bacterial suspension of E. coli and enterococci for 3 seconds, removed, and stopped. This procedure was repeated 10 times. Possible bacterial contamination of the drive air lines was examined by submersing the head of a sterilized handpiece with the turbine running into a nutrient broth for 30 seconds. The broth was incubated at 35 degrees C up to 2 days. After use of the conventional dental unit, bacterial growth of drive air lines was found in 10 of 150 broth samples. After the installation of the antisuction device no bacterial growth was found in any of the 138 samples. The difference in the contamination frequencies is statistically significant (p = 0.011, Fisher's two-sided exact test). The drive air lines of the turbine in the dental unit may become contaminated despite the sterilization of handpieces. The antisuction device installed into the dental unit was found to prevent the contamination. With the exception of possibly immunocompromised patients, the transmission of microbes by exhaust air may be too small to cause infections. However, transmission of oral material between patients should be prevented in dental practice.

  13. Should electronic faucets be used in intensive care and hematology units?

    PubMed

    Merrer, Jacques; Girou, Emmanuelle; Ducellier, David; Clavreul, Nicole; Cizeau, Florence; Legrand, Patrick; Leneveu, Michel

    2005-12-01

    To compare bacterial contamination associated with electronic faucets and manual faucets in wards admitting patients highly susceptible to infection. Water samples from electronic faucets and manual faucets were taken according to the French recommendations on water surveillance in healthcare settings. Hematology and intensive care units (ICUs) of a 900-bed university hospital and a 500-bed general hospital. Overall 227 water samples were collected, 92 from electronic faucets and 135 from manual faucets. Thirty-six (39%) of the water samples from electronic faucets and 2 (1%) from manual faucets yielded pathogenic bacteria. In hematology wards 17 (30%) samples from electronic faucets and 2 (2%) from manual faucets were contaminated. In ICUs 19 (53%) samples from electronic faucets and none of 48 from manual faucets were contaminated. All samples were contaminated with various strains of Pseudomonas aeruginosa (8 to >100 CFU/100 ml). Despite hyperchlorination the electronic faucets remained contaminated. Replacing the contaminated electronic faucets by manual faucets led to a complete and sustained elimination of bacterial contamination. Contamination was not associated with a particular brand of electronic faucets. Our findings demonstrate that electronic faucets are significantly more frequently contaminated than manual faucets and could be a major reservoir for P. aeruginosa. Wards admitting patients highly susceptible to infection and using electronic faucets should be aware of this potential threat. Moreover, units already equipped with these devices, should check water quality periodically.

  14. Establishment of a medium-scale mosquito facility: optimization of the larval mass-rearing unit for Aedes albopictus (Diptera: Culicidae).

    PubMed

    Zhang, Dongjing; Zhang, Meichun; Wu, Yu; Gilles, Jeremie R L; Yamada, Hanano; Wu, Zhongdao; Xi, Zhiyong; Zheng, Xiaoying

    2017-11-13

    Standardized larval rearing units for mosquito production are essential for the establishment of a mass-rearing facility. Two larval rearing units, developed respectively by the Guangzhou Wolbaki Biotech Co. Ltd. (Wolbaki) and Insect Pest Control Laboratory, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture (FAO/IAEA-IPCL), are tested to assess their potential uses to mass-rear the larval stages of Aedes albopictus in support of the establishment of a medium-scale mosquito facility for the application of mosquito genetic control strategies. The triple Wolbachia-infected Ae. albopictus strain (HC strain) was used in this study. The effects of larval densities of two larval rearing trays (corresponding to 2.4, 3.0 and 3.6 larvae/cm 2 ) and tray size/position (top, middle and bottom layers) on the pupae production and larval survival were assessed when trays were stacked within the larval rearing units. The male pupae production, female pupae contamination after sex separation, and male mating competitiveness were also studied by using both larval rearing units in their entirety. The optimal larval rearing density for Wolbaki-tray (Wol-tray) was 6,600 larvae (equal to 3.0 larvae/cm 2 ) and 18,000 larvae (3.6 larvae/cm 2 ) for the FAO/IAEA-IPCL tray (IAEA-tray). No significant difference in pupae production was observed when trays were stacked within top, middle or bottom layers for both units. At thirty-four hours after the first pupation, the average male pupae production was (0.89 × 10 5 ) for the Wol-unit and (3.16 × 10 5 ) for the IAEA-unit. No significant difference was observed in female pupae contamination between these two units. The HC males showed equal male mating competitiveness to wild type males for mating with wild type females in large cages, regardless of whether they were reared in the Wol-unit or IAEA-unit. The current study has indicated that both the Wol-unit and IAEA-unit are suitable for larvae mass-rearing for Ae. albopictus. However, the IAEA-unit, with higher male production and less space required compared to the Wol-unit, is recommended to be used in support of the establishment of a medium-sized mosquito facility.

  15. INEEL Subregional Conceptual Model Report; Volume 1 - Summary of Existing Knowledge of Natural and Anthropogenic Influences Governing Subsurface Contaminant Transport in the INEEL Subregion of the Eastern Snake River Plain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wichlacz, Paul Louis; Orr, Brennan

    2002-08-01

    The National Research Council has defined a conceptual model as ''an evolving hypothesis identifying the important features, processes, and events controlling fluid flow and contaminant transport of consequence at a specific field site in the context of a recognized problem''. Presently, several subregional conceptual models are under development at the Idaho National Engineering and Environmental Laboratory (INEEL). Additionally, facility-specific conceptual models have been described as part of INEEL environmental restoration activities. Compilation of these models is required to develop a comprehensive conceptual model that can be used to strategically plan for future groundwater research activities at the INEEL. Conceptual modelsmore » of groundwater flow and contaminant transport at the INEEL include the description of the geologic framework, matrix hydraulic properties, and inflows and outflows. They also include definitions of the contaminant source term and contaminant transport mechanisms. The geologic framework of the INEEL subregion is described by the geometry of the system, stratigraphic units within the system, and structural features that affect groundwater flow and contaminant transport. These elements define geohydrologic units that make up the Snake River Plain Aquifer (SRPA). The United States Geological Survey (USGS) conceptual model encompasses approximately 1,920 mi2 of the eastern Snake River Plain. The Waste Area Group (WAG)-10 model includes the USGS area and additional areas to the northeast and southeast. Both conceptual models are bounded to the northwest by the Pioneer Mountains, Lost River Range, and Lemhi Mountains. They are bounded to the southeast by groundwater flow paths determined from aquifer water-level contours. The upgradient extent of the USGS model is a water-level contour that includes the northeastern boundary of the INEEL. The WAG-10 model includes more of the Mud Lake area to utilize previous estimates of underflow into the subregion. Both conceptual models extend approximately 25 miles to the southwest of the INEEL, a distance sufficient to include known concentrations of contaminant tracers. Several hypotheses have been developed concerning the effective thickness of the SRPA at the INEEL. The USGS model has defined the effective thickness from electrical resistivity and borehole data to be as much as 2,500 ft in the eastern part of the subregion and as much as 4,000 ft in the southwestern part. The WAG-10 model has developed two alternatives using aquifer-temperature and electrical resistivity data. The ''thick'' aquifer interpretation utilizes colder temperature data and includes a northtrending zone in which the thickness exceeds 1,300 ft and with a maximum thickness of 1,700 ft. The ''thin'' aquifer interpretation minimizes aquifer thickness, with thickness ranging from 328 to 1,300 ft. Facility-specific models generally have focused efforts on the upper 250 ft of saturation. Conceptual models have utilized a stratigraphic data set to define geohydrologic units within the INEEL subregion. This data set, compiled from geophysical logs and cores from boreholes, correlates the thick, complex stack of basalt flows across the subregion. Conceptual models generally concur that the upper geohydrologic unit consists of a section of highly fractured, multiple, thin basalt flows and sedimentary interbeds. Beneath this unit is an areally extensive, thick, unfractured basalt flow that rises above the water table southwest of the INEEL. The bottom unit consists of a thick section of slightly- to moderately-altered basalt. A key objective of the DOE water-integration project at the INEEL is to coordinate development of a subregional conceptual model of groundwater flow and contaminant transport that is based on the best available understanding of geologic and hydrologic features. The first step in this process is to compile and summarize the current conceptual models of groundwater flow and contaminant transport at the INEEL that have been developed from extensive geohydrologic studies conducted during the last 50 years.« less

  16. Contamination control plan for prelaunch operations

    NASA Technical Reports Server (NTRS)

    Austin, J. D.

    1983-01-01

    A unified, systematic plan is presented for contamination control for space flight systems. Allowable contaminant quantities, or contamination budgets, are determined based on system performance margins and system-level allowable degradations. These contamination budgets are compared to contamination rates in ground environments to establish the controls required in each ground environment. The use of feedback from contamination monitoring and some contamination control procedures are discussed.

  17. Monticello Mill Tailings Site, Operable Unit lll, Annual Groundwater Report, May 2015 Through April 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Jason; Smith, Fred

    This report provides the annual analysis of water quality restoration progress, cumulative through April 2016, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of wastemore » (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site, Operable Unit I (OU I), and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. This effectively removed the primary source of groundwater contamination; however, contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern (COC). LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and­ treat system using a single extraction well and treatment by zero-valent iron (ex situ treatment system). The contingency action was optimized in 2015 with the installation of8 extraction wells and 16 monitoring wells in a focused area of the aquifer, the area of attainment (AOA). Contaminated water is treated by solar evaporation at an existing facility at the LM repository.« less

  18. DISTRIBUTION OF ORGANIC WASTEWATER CONTAMINANTS BETWEEN WATER AND SEDIMENT IN SURFACE WATERS OF THE UNITED STATES

    EPA Science Inventory

    Trace concentrations of pharmaceuticals and other organic wastewater contaminants have been determined in the surface waters of Europe and the United States. A preliminary report of substantially higher concentrations of pharmaceuticals in sediment suggests that bottom sediment ...

  19. 75 FR 10669 - Airworthiness Directives; The Boeing Company Model 747-100, 747-200B, 747-300, and 747SR Series...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-09

    ... results from a report of water contamination in the electrical and electronic units in the main equipment... from a report of water contamination in the electrical and electronic units in the main equipment...

  20. EPA RREL'S MOBILE VOLUME REDUCTION UNIT -- APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    The volume reduction unit (VRU) is a pilot-scale, mobile soil washing system designed to remove organic contaminants from the soil through particle size separation and solubilization. The VRU removes contaminants by suspending them in a wash solution and by reducing the volume of...

  1. Chemical looping integration with a carbon dioxide gas purification unit

    DOEpatents

    Andrus, Jr., Herbert E.; Jukkola, Glen D.; Thibeault, Paul R.; Liljedahl, Gregory N.

    2017-01-24

    A chemical looping system that contains an oxidizer and a reducer is in fluid communication with a gas purification unit. The gas purification unit has at least one compressor, at least one dryer; and at least one distillation purification system; where the gas purification unit is operative to separate carbon dioxide from other contaminants present in the flue gas stream; and where the gas purification unit is operative to recycle the contaminants to the chemical looping system in the form of a vent gas that provides lift for reactants in the reducer.

  2. Initial Field Deployment Results of Green PCB Removal from Sediment Systems (GPRSS)

    NASA Technical Reports Server (NTRS)

    Devor, Robert; Captain, James; Weis, Kyle; Maloney, Phillip; Booth, Greg; Quinn, Jacqueline

    2014-01-01

    Purpose of Study: (a) Develop/optimize technology capable of removing PCBs from contaminated sediments; (b) Develop design for functional GPRSS unit; (c) Produce and prove functionality of prototype units in a laboratory settings; (d) Produce fully-functional GPRSS units for testing at a demonstration site in Altavista, VA; and (e) Evaluate efficacy of GPRSS technology for the remediation of PCB-contaminated sediments.

  3. Evaluation of sprayable fixatives on a sandy soil for potential use in a dirty bomb response.

    PubMed

    Fritz, Brad G; Whitaker, John D

    2008-06-01

    After the events of 11 September 2001, the possibility of a dirty bomb being detonated within the United States seems more realistic. Development of tools for use in response to a dirty bomb detonation has become a topic of both discussion and research. While it has been reported that the health risk to the public from such an event would likely be small, it is thought that the psychological impact could be considerable. One response option that has been considered is adapting sprayable solutions for the purpose of fixing contamination in place, thereby limiting the spread of contamination by wind and rain and facilitating subsequent cleanup. This work evaluated two commercially available particle fixatives (IsoFIX-HT and IsoFIX-RC) for their effectiveness in preventing dispersal of simulated contamination. Nonradioactive cesium chloride and cobalt oxide particles were selected as the simulated contamination and applied to the surface of three outdoor test plots. Two test plots were treated with fixatives; the third plot provided a control. Samples were collected over 95 days to observe changes in tracer concentration on the surface of the test plots. One fixative (IsoFIX-RC) effectively held the tracer in place with no net loss of tracer, while the other fixative (IsoFIX-HT) had no impact on the loss of tracer relative to the control. Under the conditions tested, IsoFIX-RC appears capable of fixing surface contamination in place for at least several months.

  4. Internal contamination of an irradiator discovered during security enhancement.

    PubMed

    Harvey, R P

    2014-08-01

    High-risk radioactive sources regulated under Increased Controls Regulations have been protected by licensed facilities, but the federal government has placed significant emphasis on these sources and has developed initiatives to assist radioactive material licensees. The Department of Energy's Global Threat Reduction Initiative (GTRI) Domestic Threat Reduction Program is a voluntary federally funded program for security enhancements of high-risk radiological material. During the hardening or security enhancement process by the United States Department of Energy (U.S. DOE) contractors, a small amount of radioactive contamination was discovered in a Cesium irradiator. Ultimately, it was decided to pursue disposal with U.S. DOE's Off-Site Recovery Program (OSRP). Radiological devices may have a leaking source or known internal contamination that may cause difficulty during security enhancement. If the licensee understands this, it may provide facilities the opportunity to plan and prepare for unusual circumstances.

  5. Heat stress control in the TMI-2 (Three Mile Island Unit 2) defueling and decontamination activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schork, J.S.; Parfitt, B.A.

    During the initial stages of the Three Mile Island Unit 2 (TMI-2) defueling and decontamination activities for the reactor building, it was realized that the high levels of loose radioactive contamination would require the use of extensive protective clothing by entry personnel. While there was no doubt that layered protective clothing protects workers from becoming contaminated, it was recognized that these same layers of clothing would impose a very significant heat stress burden. To prevent the potentially serious consequences of a severe reaction to heat stress by workers in the hostile environment of the TMI-2 reactor building and yet maintainmore » the reasonable work productivity necessary to perform the recovery adequately, an effective program of controlling worker exposure to heat stress had to be developed. Body-cooling devices produce a flow of cool air, which is introduced close to the skin to remove body heat through convection and increased sweat evaporation. The cooling effect produced by the Vortex tube successfully protected the workers from heat stress, however, there were several logistical and operational problems that hindered extensive use of these devices. The last type of cooling garment examined was the frozen water garment (FWG) developed by Elizier Kamon at the Pennsylvania State University as part of an Electric Power Research Institute research grant. Personal protection, i.e., body cooling, engineering controls, and administrative controls, have been implemented successfully.« less

  6. Effect of nitrate and ammonium fertilization on Zn, Pb, and Cd phytostabilization by Populus euramericana Dorskamp in contaminated technosol.

    PubMed

    Qasim, Bashar; Motelica-Heino, Mikael; Bourgerie, Sylvain; Gauthier, Arnaud; Morabito, Domenico

    2015-12-01

    This study aimed at assessing the effect of nitrogen addition under two forms, nitrate and ammonium, on the stabilization of Zn, Pb, and Cd by Populus euramericana Dorskamp grown in contaminated soils for 35 days under controlled conditions. Temporal changes in the soil pore water (SPW) were monitored for pH, dissolved organic carbon (DOC), and total dissolved concentrations of metals in the soils rhizosphere. Rhizospheric SPW pH decreased gradually with NH4(+) addition and increased with NO3(-) addition up to one unit, while it slightly decreased initially then increased for the untreated control soil DOC increased with time up to six times, the highest increase occurring with NH4(+) fertilization. An increase in the metal concentrations in the rhizospheric SPW was observed for NH4(+) addition associated with the lowest rhizospheric SPW pH, whereas the opposite was observed for the control soil and NO3(-) fertilization. Fertilization did not affect plant shoots or roots biomass development compared to the untreated control (without N addition). Metals were mostly accumulated in the rhizosphere and N fertilization increased the accumulation for Zn and Pb while Cd accumulation was enhanced for NH4(+) addition. Collectively, our results suggest metal stabilization by P. euramericana Dorskamp rhizosphere with nitrogen fertilization and are potential for phytostabilization of contaminated technosol.

  7. Regenerable non-venting thermal control subsystem for extravehicular activity

    NASA Technical Reports Server (NTRS)

    Roebelen, George J.; Bayes, Stephen A.; Lawson, B. Mike

    1986-01-01

    Routine and complex EVAs call for more effective heat rejection systems in order to maximize mission productivity; an optimum EVA mobility unit (EMU) thermal control subsystem must require no expendables and introduce no contaminants into the environment, while conforming to minimum size limits and allowing easy regeneration. Attention is presently given to two thermal control subsystems, one of which can be integrated with the existing Space Shuttle Orbiter EMU to provide a 3-hour nonventing heat rejection capability, while the other can furnish the entire heat rejection capability requirement for an 8-hour Space Station EVA.

  8. A multi-disciplinary approach to the removal of emerging contaminants in municipal wastewater treatment plans in New York State, 2003-2004

    USGS Publications Warehouse

    Philips, Patrick J.; Stinson, Beverley; Zaugg, Steven D.; Furlong, Edward T.; Kolpin, Dana W.; Esposito, Kathleen; Bodniewicz, B.; Pape, R.; Anderson, J.

    2005-01-01

    The second phase of the study focused on one of the most common wastewater treatment processes operated in the United States, the Activated Sludge process. Using four controlled parallel activated sludge pilots, a more detailed assessment of the impact of Sludge Retention Time (SRT) on the reduction or removal of ECs was performed.

  9. Perchlorate Contamination of Drinking Water: Regulatory Issues and Legislative Actions

    DTIC Science & Technology

    2007-04-04

    al., “Primary Congenital Hypothyroidism , Newborn Thyroid Function, and Environmental Perchlorate Exposure Among Residents of a Southern California...Thyroid Hormone Levels in Adolescent and Adult Men and Women Living in the United States,” Centers for Disease Control and Prevention, in Environmental...identified hypothyroidism as the first adverse effect. Because of research gaps regarding perchlorate’s potential effects following changes in thyroid

  10. Evaluation of Innovative Volatile Organic Compound and Hazardous Air Pollutant Control Technologies for U.S. Air Force Paint Spray Booths

    DTIC Science & Technology

    1990-10-01

    adsorption/incineration * Membrane vapor separation/condensation * Supercritical fluid oxidation • UV/ozone destruction * Molten salt combustion process...separation/ separate air stream contaminants 9 Oxygenated solvents condensation * Chlorinated hydrocarbons Supercritical fluid * Technology utilizing high...testing or full-scale unit capacity; they are: * Supercritical fluid oxidation • UV/ozone destruction * Molten salt incineration * Infrared incineration

  11. Environmental contaminant exposure data and monitoring priorities for wild terrestrial vertebrates at national parks in coastal and estuarine habitat

    USGS Publications Warehouse

    Rattner, B.A.; Ackerson, B.K.; Eisenreich, K.M.; McKernan, M.A.; Harmon, David

    2006-01-01

    The Biomonitoring of Environmental Status and Trends (BEST) Project of the U.S. Geological Survey (USGS) assesses the exposure and effects of environmental contaminants on select species and habitats in the United States. One of the many BEST Project activities entails the development of decision-support tools to assist in the identification of chemical threats to species and lands under the stewardship of the Department of the Interior. Although there are many ecotoxicological monitoring programs that focus on aquatic species and habitats, there are currently no large-scale efforts that are focused on terrestrial vertebrates in the United States. Nonetheless, organochlorine contaminants, metals, and new pollutants continue to pose hazards to terrestrial vertebrates at many spatial scales (ranging from small hazardous-waste-site point sources to entire watersheds). To evaluate and prioritize pollutant hazards for terrestrial vertebrates, a ?Contaminant Exposure and EffectsTerrestrial Vertebrates? (CEE-TV) database (www.pwrc.usgs.gov/contaminants-online) was developed. The CEE-TV database has been used to conduct simple searches for exposure and biological effects information for a given species or location, identification of temporal contaminant exposure trends, information gap analyses for national wildlife refuge and national park units, and ranking of terrestrial vertebrate ecotoxicological information needs based on data density and water quality problems. Despite widespread concerns about environmental contamination, during the past decade only about one-half of the coastal National Park units appear to have terrestrial vertebrate ecotoxicological data. Based upon known environmental contaminant hazards, it is recommended that regionalized monitoring programs or efforts focused on lands managed by the Department of the Interior should be undertaken to prevent serious natural resource problems.

  12. Microbial diversity in dental unit waterlines.

    PubMed

    Lisboa, Guacyra M; Lisboa, Yves R M; Pinheiro, Telma M L; Stegun, Roberto C; da Silva-Filho, Eurípedes A

    2014-01-01

    Dental health care providers and patients are exposed during ongoing work to contamination by the water used in the dental units, due to accidental swallowing or aspiration of the sprays generated by the high-speed handpiece and the threeway syringe. This study evaluated the quality of water in dental units in the public dental care system of Maceio, Alagoas, Brazil, by conducting analyses of contamination by total coliforms, E.Coli, heterotrophic bacteria and filamentous fungi. We collected 200 mL of water at 5 sites in 6 dental offices of the Department of Health located in different parts of the city. A total 212 isolates and 16 genera of filamentous fungi were identified in the water collected from the dental units. Total coliforms indicated that the water used in dental units was not appropriate for human consumption. The high levels of contamination found in this study showed that water was a potential source of cross-infection.

  13. Efficacy of anti-retraction devices in preventing bacterial contamination of dental unit water lines.

    PubMed

    Berlutti, Francesca; Testarelli, Luca; Vaia, Francesco; De Luca, Massimo; Dolci, Giovanni

    2003-02-01

    In this study we examine the efficacy of anti-retraction devices in preventing microbial contamination of dental unit water lines (DUWLs). The study was performed on 54 randomly selected DUs in use at private and public institutions for over six months. The selected DUs were all currently commercially available. To evaluate the efficiency of anti-retraction devices, two different methods were employed, mechanical and microbiological. The ADA/ANSI specification #47 (corresponding to a water retraction of less than 40.3 microl) was used for the evaluation of the retraction determined using the mechanical method; the presence/absence of test microorganisms in DUWLs upstream the turbine after the test was used for evaluating the microbiological assay. Both evaluation methods indicated correct amounts of retraction and prevention of DUWL contamination occurred in only two cases (3.7%). Correct retraction was noted in six other dental units (DUs), but their DUWLs became contaminated during testing. Six other produced the opposite results-improper retraction, yet no contamination. The remaining 40 DUs (74.0%) failed both evaluations. The results showed that the overwhelming majority of the anti-retraction devices did not prevent retraction when the turbine stopped running, leading to a contamination of the water lines, and to a consequent possible cross-contamination of the patients.

  14. Corrective Action Decision Document/Closure Report for Corrective Action Unit 569: Area 3 Yucca Flat Atmospheric Test Sites Nevada National Security Site, Nevada with ROTC 1, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sloop, Christy

    2013-04-01

    This Corrective Action Decision Document/Closure Report presents information supporting the closure of Corrective Action Unit (CAU) 569: Area 3 Yucca Flat Atmospheric Test Sites, Nevada National Security Site, Nevada. CAU 569 comprises the following nine corrective action sites (CASs): • 03-23-09, T-3 Contamination Area • 03-23-10, T-3A Contamination Area • 03-23-11, T-3B Contamination Area • 03-23-12, T-3S Contamination Area • 03-23-13, T-3T Contamination Area • 03-23-14, T-3V Contamination Area • 03-23-15, S-3G Contamination Area • 03-23-16, S-3H Contamination Area • 03-23-21, Pike Contamination Area The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supportingmore » the recommendation that no further corrective action is needed for CAU 569 based on the implementation of the corrective actions listed in Table ES-2.« less

  15. Space station contamination control study: Internal combustion, phase 1

    NASA Technical Reports Server (NTRS)

    Ruggeri, Robert T.

    1987-01-01

    Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

  16. Pharmaceuticals and organochlorine pesticides in sediments of an urban river in Florida, United States

    USDA-ARS?s Scientific Manuscript database

    Purpose Sediments from a rural to urban gradient along the Alafia River in Florida, United States were investigated to determine the risk of environmental contamination with legacy (organochlorine pesticides, OCPs) and new contaminants (pharmaceuticals). Materials and methods Bed sediments (0-10 cm)...

  17. DEMONSTRATION BULLETIN: MOBILE VOLUME REDUCTION UNIT - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The Volume Reduction Unit (VRU), which was developed by EPA, is a mobile, pilot-scale soil washing system for stand-alone field use in cleaning soil contaminated with hazardous substances. Removal efficiencies depend on the contaminant as well as the type of soil. Soil washing...

  18. Microbial contamination in dental unit waterlines: comparison between Er:YAG laser and turbine lines.

    PubMed

    Sacchetti, Rossella; Baldissarri, Augusto; De Luca, Giovanna; Lucca, Paola; Stampi, Serena; Zanetti, Franca

    2006-01-01

    The investigation was carried out by evaluating the microbiological characteristics of the water before and after treatment with Er:YAG laser and turbine. The study was carried out in 2 dental surgeries. In both cases the laser and dental units were served by two independent circuits, fed by the same potable tap water. Samples were taken from the water supplying and the water leaving the turbine and laser before and after treatment on the same patient. Total heterotrophic plate count was measured at 36 degrees C and at 22 degrees C, and the presence of Staphylococcus species and non-fermenting Gram negative bacteria was investigated. Bacterial contamination was found within the circuit, especially in the laser device. Pseudomonas aeruginosa was detected in only 1 sample of supply water, in 11.1 % and in 19.4 % of the samples from the turbine and the laser respectively. No evidence of Staphylococcus aureus was found. The contamination of supply water was low, whereas that of the water leaving the handpieces of the 2 devices was high, especially in the laser. Attention should be paid to the control of the water leaving laser devices, given the increasingly wide use of such instruments in dental treatment exposed to risk of infection.

  19. Environmental contaminant hazards to wildlife at National Capital region and Mid-Atlantic National Park Service units

    USGS Publications Warehouse

    Rattner, B.A.; Ackerson, B.K.; Weber, S.; Harmon, David

    2008-01-01

    Pollutant data for air, water, soil and biota were compiled from databases and internet sources and by staff interviews at 23 National Park Service (NPS) units in 2005. A metric was derived describing the quality and quantity of data for each park, and in combination with known contaminant threats, the need for ecotoxicological study was identified and ranked. Over half of NP units were near Toxic Release Inventory sites discharging persistent pollutants, and fish consumption advisories were in effect at or near 22 of the units. Pesticide and herbicide use was found to be minimal, with the exception of those units with agricultural leases. Only 70 reports were found that describe terrestrial vertebrate environmental contaminant data at or near the units. Of the >75,000 compounds in commerce, empirical exposure data were limited to merely 58 halogenated compounds, insecticides, rodenticides, metals, and some contemporary compounds. Further ecotoxicological monitoring and research is warranted at several units including Shenandoah National Park, Richmond National Battlefield Park, Chesapeake & Ohio Canal National Historical Park, Valley Forge National Historical Park, Hopewell Furnace National Historic Site, Monocacy National Battlefield, and Harpers Ferry National Historical Park. The types of investigations vary according to the wildlife species present and potential contaminant threats, but should focus on contemporary use pesticides and herbicides, polychlorinated biphenyls, mercury, lead, and perhaps antibiotics, flame retardants, pharmaceuticals, and surfactants. Other management recommendations include inclusion of screening level contaminant risk assessments into the NPS Vital Signs Program, development of protocols for toxicological analysis of seemingly affected wildlife, alternative methods and compounds for pest management, and use of non-toxic fishing tackle by visitors.

  20. Development and Testing of the Contaminant Insensitive Sublimator

    NASA Technical Reports Server (NTRS)

    Leimkuehler, Thomas O.; Stephan, Ryan A.; Westheimer, David T.

    2006-01-01

    Sublimators have been used for heat rejection for a variety of space applications including the Apollo Lunar Module and the Extravehicular Mobility Unit (EMU). Some of the attractive features of sublimators are that they are compact, lightweight, and self-regulating. One of the drawbacks of previous designs has been sensitivity to non-volatile contamination in the feedwater, which can clog relatively small pores (approx.3-6 microns) in the porous plates where ice forms and sublimates. A new design that is less sensitive to contaminants is being developed at the Johnson Space Center. This paper describes the design, fabrication, and testing of the Contaminant Insensitive Sublimator (CIS) Engineering Development Unit (EDU).

  1. Corrective Action Decision Document/Closure Report for Corrective Action Unit 375: Area 30 Buggy Unit Craters, Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patrick Matthews

    2011-08-01

    Corrective Action Unit 375 comprises three corrective action sites (CASs): (1) 25-23-22, Contaminated Soils Site; (2) 25-34-06, Test Cell A Bunker; and (3) 30-45-01, U-30a, b, c, d, e Craters. The purpose of this CADD/CR is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 375 based on the implementation of corrective action of closure in place with administrative controls at CAS 25-23-22, no further action at CAS 25-34-06, and closure in place with administrative controls and removal of potential source material (PSM) at CAS 30-45-01. Corrective action investigation (CAI) activities weremore » performed from July 28, 2010, through April 4, 2011, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 375: Area 30 Buggy Unit Craters. The approach for the CAI was divided into two facets: investigation of the primary release of radionuclides, and investigation of other releases (migration in washes and chemical releases). The purpose of the CAI was to fulfill data needs as defined during the data quality objective (DQO) process. The CAU 375 dataset of investigation results was evaluated based on the data quality assessment. This assessment demonstrated the dataset is acceptable for use in fulfilling the DQO data needs. Investigation results were evaluated against final action levels (FALs) established in this document. A radiological dose FAL of 25 millirem per year was established based on the Remote Work Area exposure scenario (336 hours of annual exposure). Radiological doses exceeding the FAL were assumed to be present within the default contamination boundaries at CASs 25-23-22 and 30-45-01. No contaminants were identified at CAS 25-34-06, and no corrective action is necessary. Potential source material in the form of lead plate, lead-acid batteries, and oil within an abandoned transformer were identified at CAS 30-45-01, and corrective actions were undertaken that consisted of removing the PSM. Use restrictions and warning signs were implemented for the remaining radiological contamination at CASs 25-23-22 and 30-45-01. These use restrictions were recorded in the FFACO database; the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Facility Information Management System; and the NNSA/NSO CAU/CAS files. Therefore, NNSA/NSO provides the following recommendations: (1) No further corrective actions are necessary for CAU 375; (2) A Notice of Completion to NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 375; and (3) Move CAU 375 from Appendix III to Appendix IV of the FFACO.« less

  2. Contrasting the Community Structure of Arbuscular Mycorrhizal Fungi from Hydrocarbon-Contaminated and Uncontaminated Soils following Willow (Salix spp. L.) Planting

    PubMed Central

    Stefani, Franck O. P.; Denis, David; Hijri, Mohamed; St-Arnaud, Marc

    2014-01-01

    Phytoremediation is a potentially inexpensive alternative to chemical treatment of hydrocarbon-contaminated soils, but its success depends heavily on identifying factors that govern the success of root-associated microorganisms involved in hydrocarbon degradation and plant growth stimulation. Arbuscular mycorrhizal fungi (AMF) form symbioses with many terrestrial plants, and are known to stimulate plant growth, although both species identity and the environment influence this relationship. Although AMF are suspected to play a role in plant adaptation to hydrocarbon contamination, their distribution in hydrocarbon-contaminated soils is not well known. In this study, we examined how AMF communities were structured within the rhizosphere of 11 introduced willow cultivars as well as unplanted controls across uncontaminated and hydrocarbon-contaminated soils at the site of a former petrochemical plant. We obtained 69 282 AMF-specific 18S rDNA sequences using 454-pyrosequencing, representing 27 OTUs. Contaminant concentration was the major influence on AMF community structure, with different AMF families dominating at each contaminant level. The most abundant operational taxonomic unit in each sample represented a large proportion of the total community, and this proportion was positively associated with increasing contamination, and seemingly, by planting as well. The most contaminated soils were dominated by three phylotypes closely related to Rhizophagus irregularis, while these OTUs represented only a small proportion of sequences in uncontaminated and moderately contaminated soils. These results suggest that in situ inoculation of AMF strains could be an important component of phytoremediation treatments, but that strains should be selected from the narrow group that is both adapted to contaminant toxicity and able to compete with indigenous AMF species. PMID:25032685

  3. Contamination Control for Thermal Engineers

    NASA Technical Reports Server (NTRS)

    Rivera, Rachel B.

    2015-01-01

    The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). This course will cover the basics of Contamination Control, including contamination control related failures, the effects of contamination on Flight Hardware, what contamination requirements translate to, design methodology, and implementing contamination control into Integration, Testing and Launch.

  4. Space station trace contaminant control

    NASA Technical Reports Server (NTRS)

    Olcutt, T.

    1985-01-01

    Different systems for the control of space station trace contaminants are outlined. The issues discussed include: spacecabin contaminant sources, technology base, contaminant control system elements and configuration, approach to contaminant control, contaminant load model definition, spacecraft maximum allowable concentrations, charcoal bed sizing and performance characteristics, catalytic oxidizer sizing and performance characteristics, special sorbent bed sizing, animal and plant research payload problems, and emergency upset contaminant removal. It is concluded that the trace contaminant control technology base is firm, the necessary hardware tools are available, and the previous design philosophy is still applicable. Some concerns are the need as opposed to danger of the catalytic oxidizer, contaminants with very low allowable concentrations, and the impact of relaxing materials requirements.

  5. Heavy Metal Contamination in Groundwater around Industrial Estate vs Residential Areas in Coimbatore, India

    PubMed Central

    Mohankumar, K.; Rao, N. Prasada

    2016-01-01

    Introduction Water is the vital resource, necessary for all aspects of human and ecosystem survival and health. Depending on the quality, bore water may be used for human consumption, irrigation purposes and livestock watering. The quality of bore water can vary widely depending on the quality of ground water that is its source. Pollutants are being added to the ground water system through human and natural processes. Solid waste from industrial units is being dumped near the factories, which react with percolating rainwater and reaches the ground water. The percolating water picks up a large number of heavy metals and reaches the aquifer system and contaminates the ground water. The usage of the contaminated bore water causes the diseases. Mercury, Arsenic and Cadmium are used or released by many industries. Aim This study was conducted to investigate the pollution of bore water in the industrial region (Kurichi Industrial Cluster) of Coimbatore, in the state of Tamilnadu, India. Materials and Methods Four samples were taken from residential areas around Kurichi Industrial Cluster and analysed to find the concentrations of Mercury, Arsenic and Cadmium. Four more samples were taken from other residential regions far from the industrial estate and served as control. Samples were analysed using Atomic absorption spectrophotometry method. Results We found that the ground water of the areas surrounding the industrial cluster does not contain significant amount of those metals. Instead, Heavy metal contamination of ground water were observed in some residential areas of coimbatore. Conclusion The regulatory measures to contain and prevent ground water contamination by industries undertaken by Tamilnadu pollution control board may have lead to absence of heavy metal contamination in Kurichi Industrial cluster, Coimbatore, India. PMID:27190788

  6. Treatment of Alkaline Cr(VI)-Contaminated Leachate with an Alkaliphilic Metal-Reducing Bacterium.

    PubMed

    Watts, Mathew P; Khijniak, Tatiana V; Boothman, Christopher; Lloyd, Jonathan R

    2015-08-15

    Chromium in its toxic Cr(VI) valence state is a common contaminant particularly associated with alkaline environments. A well-publicized case of this occurred in Glasgow, United Kingdom, where poorly controlled disposal of a cementitious industrial by-product, chromite ore processing residue (COPR), has resulted in extensive contamination by Cr(VI)-contaminated alkaline leachates. In the search for viable bioremediation treatments for Cr(VI), a variety of bacteria that are capable of reduction of the toxic and highly soluble Cr(VI) to the relatively nontoxic and less mobile Cr(III) oxidation state, predominantly under circumneutral pH conditions, have been isolated. Recently, however, alkaliphilic bacteria that have the potential to reduce Cr(VI) under alkaline conditions have been identified. This study focuses on the application of a metal-reducing bacterium to the remediation of alkaline Cr(VI)-contaminated leachates from COPR. This bacterium, belonging to the Halomonas genus, was found to exhibit growth concomitant to Cr(VI) reduction under alkaline conditions (pH 10). Bacterial cells were able to rapidly remove high concentrations of aqueous Cr(VI) (2.5 mM) under anaerobic conditions, up to a starting pH of 11. Cr(VI) reduction rates were controlled by pH, with slower removal observed at pH 11, compared to pH 10, while no removal was observed at pH 12. The reduction of aqueous Cr(VI) resulted in the precipitation of Cr(III) biominerals, which were characterized using transmission electron microscopy and energy-dispersive X-ray analysis (TEM-EDX) and X-ray photoelectron spectroscopy (XPS). The effectiveness of this haloalkaliphilic bacterium for Cr(VI) reduction at high pH suggests potential for its use as an in situ treatment of COPR and other alkaline Cr(VI)-contaminated environments. Copyright © 2015, Watts et al.

  7. Integrated System Design for Air Revitalization in Next Generation Crewed Spacecraft

    NASA Technical Reports Server (NTRS)

    Mulloth, Lila; Perry, Jay; LeVan, Douglas

    2004-01-01

    The capabilities of NASA's existing environmental control and life support (ECLS) system designs are inadequate for future human space initiatives that involve long-duration space voyages and interplanetary missions. This paper discusses the concept of an integrated system of CO2 removal and trace contaminant control units that utilizes novel gas separation and purification techniques and optimized thermal and mechanical design, for future spacecraft. The integration process will enhance the overall life and economics of the existing systems by eliminating multiple mechanical devices with moving parts.

  8. Stored Canine Whole Blood Units: What is the Real Risk of Bacterial Contamination?

    PubMed

    Miglio, A; Stefanetti, V; Antognoni, M T; Cappelli, K; Capomaccio, S; Coletti, M; Passamonti, F

    2016-11-01

    Bacterial contamination of whole blood (WB) units can result in transfusion-transmitted infection, but the extent of the risk has not been established and may be underestimated in veterinary medicine. To detect, quantify, and identify bacterial microorganisms in 49 canine WB units during their shelf life. Forty-nine healthy adult dogs. Forty-nine WB units were included in the study. Immediately after collection, 8 sterile samples from the tube segment line of each unit were aseptically collected and tested for bacterial contamination on days 0, 1, 7, 14, 21, 28, 35, and 42 of storage. A qPCR assay was performed on days 0, 21, and 35 to identify and quantify any bacterial DNA. On bacterial culture, 47/49 blood units were negative at all time points tested, 1 unit was positive for Enterococcus spp. on days 0 and 1, and 1 was positive for Escherichia coli on day 35. On qPCR assay, 26 of 49 blood units were positive on at least 1 time point and the bacterial loads of the sequences detected (Propionobacterium spp., Corynebacterium spp., Caulobacter spp., Pseudomonas spp., Enterococcus spp., Serratia spp., and Leucobacter spp.) were <80 genome equivalents (GE)/μL. Most of the organisms detected were common bacteria, not usually implicated in septic transfusion reactions. The very low number of GE detected constitutes an acceptable risk of bacterial contamination, indicating that WB units have a good sanitary shelf life during commercial storage. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. Method for detecting organic contaminants in water supplies

    DOEpatents

    Dooley, K.J.; Barrie, S.L.; Buttner, W.J.

    1999-08-24

    A system is described for detecting organic contaminants in water supplies. A sampling unit is employed which includes a housing having at least one opening therein and a tubular member positioned within the housing having a central passageway surrounded by a side wall. The side wall is made of a composition designed to absorb the contaminants. In use, the sampling unit is immersed in a water supply. The water supply contacts the tubular member through the opening in the housing, with any contaminants being absorbed into the side wall of the tubular member. A carrier gas is then passed through the central passageway of the tubular member. The contaminants will diffuse out of the side wall and into the central passageway where they will subsequently combine with the carrier gas, thereby yielding a gaseous product. The gaseous product is then analyzed to determine the amount and type of contaminants therein. 5 figs.

  10. Method for detecting organic contaminants in water supplies

    DOEpatents

    Dooley, Kirk J.; Barrie, Scott L.; Buttner, William J.

    1999-01-01

    A system for detecting organic contaminants in water supplies. A sampling unit is employed which includes a housing having at least one opening therein and a tubular member positioned within the housing having a central passageway surrounded by a side wall. The side wall is made of a composition designed to absorb the contaminants. In use, the sampling unit is immersed in a water supply. The water supply contacts the tubular member through the opening in the housing, with any contaminants being absorbed into the side wall of the tubular member. A carrier gas is then passed through the central passageway of the tubular member. The contaminants will diffuse out of the side wall and into the central passageway where they will subsequently combine with the carrier gas, thereby yielding a gaseous product. The gaseous product is then analyzed to determine the amount and type of contaminants therein.

  11. 30 CFR 57.5005 - Control of exposure to airborne contaminants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Underground § 57.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention of contamination, removal by exhaust...

  12. Superfund Record of Decision (EPA Region 4): Milan Army Ammunition Plant, O-Line Ponds Area, Milan, TN, September 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-09-01

    The decision document presents the selected remedial action for Operable Unit Two (OU2) at the O-Line Ponds Area, Milan Army Ammunition Plant, Milan, Tennessee. The goal of the overall cleanup activities at the site is to prevent migration of contaminants from soil at the site and to prevent exposures to these contaminants, so that no adverse health effects will result from current or future off-post or on-post use. Soil contaminated with explosives compounds is known to exist in the O-Line Ponds area, and under current conditions, this contamination poses a potential threat to groundwater at the site. Currently contaminated groundwatermore » is being addressed by separate remedial actions under different Operable Units (OUs).« less

  13. MSFC Skylab contamination control systems mission evaluation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Cluster external contamination control evaluation was made throughout the Skylab Mission. This evaluation indicated that contamination control measures instigated during the design, development, and operational phases of this program were adequate to reduce the general contamination environment external to the Cluster below the threshold senstivity levels for experiments and affected subsystems. Launch and orbit contamination control features included eliminating certain vents, rerouting vents for minimum contamination impact, establishing filters, incorporating materials with minimum outgassing characteristics and developing operational constraints and mission rules to minimize contamination effects. Prior to the launch of Skylab, contamination control math models were developed which were used to predict Cluster surface deposition and background brightness levels throughout the mission. The report summarizes the Skylab system and experiment contamination control evaluation. The Cluster systems and experiments evaluated include Induced Atmosphere, Corollary and ATM Experiments, Thermal Control Surfaces, Solar Array Systems, Windows and Star Tracker.

  14. WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P.A. Kumar

    2000-06-21

    The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. Themore » contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is reasonably achievable) principles to maintain personnel radiation doses to all occupational workers below regulatory limits and as low as is reasonably achievable. The Waste Handling Building Ventilation System interfaces with the Waste Handling Building System by being located within the WHB and by maintaining specific pressures, temperatures, and humidity within the building. The system also depends on the WHB for water supply. The system interfaces with the Site Radiological Monitoring System for continuous monitoring of the exhaust air; the Waste Handling Building Fire Protection System for detection of fire and smoke; the Waste Handling Building Electrical System for normal, emergency, and standby power; and the Monitored Geologic Repository Operations Monitoring and Control System for monitoring and control of the system.« less

  15. Inspection of fecal contamination on strawberries using line-scan led-induced fluorescence imaging techniques

    USDA-ARS?s Scientific Manuscript database

    In the United States, fecal contamination of produce is a food safety issue because illnesses caused by associated pathogens such as Escherichia coli and Salmonella. Outbreaks of foodborne illnesses associated with consuming raw fruits and vegetables in the United States continue to be a public heal...

  16. UNITED STATES AND GERMAN BILATERAL WORKING GROUP ON REDEVELOPMENT OF POTENTIALLY CONTAMINATED SITES SITE-SPECIFIC MANAGEMENT APPROACHES AND REDEVELOPMENT TOOLS - RESOURCE (SMARTRESOURCE)

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) and the German Federal Ministry of Education and Research (BMBF) continues an ongoing partnership to gain an understanding of each other's approach to the cleanup of chemical contamination in order to protect human health ...

  17. National outbreak of Shiga toxin-producing Escherichia coli O157:H7 linked to mixed salad leaves, United Kingdom, 2016.

    PubMed

    Gobin, Maya; Hawker, Jeremy; Cleary, Paul; Inns, Thomas; Gardiner, Daniel; Mikhail, Amy; McCormick, Jacquelyn; Elson, Richard; Ready, Derren; Dallman, Tim; Roddick, Iain; Hall, Ian; Willis, Caroline; Crook, Paul; Godbole, Gauri; Tubin-Delic, Drazenka; Oliver, Isabel

    2018-05-01

    We investigated a large outbreak of Escherichia coli O157 in the United Kingdom (UK) with 165 cases between 31 May and 29 July 2016. No linked cases were reported in other countries. Cases were predominately female (n = 128) and adult (n = 150), 66 attended hospital and nine had features of haemorrhagic uraemic syndrome. A series of epidemiological studies (case-control, case-case, ingredients-based and venue-based studies) and supply chain investigations implicated mixed salad leaves from Supplier A as the likely outbreak vehicle. Whole genome sequencing (WGS) indicated a link with strains from the Mediterranean and informed the outbreak control team to request that Supplier A cease distributing salad leaves imported from Italy. Microbiological tests of samples of salad leaves from Supplier A were negative. We were unable to confirm the source of contamination or the contaminated constituent leaf although our evidence pointed to red batavia received from Italy as the most likely vehicle. Variations in Shiga toxin-producing E. coli surveillance and diagnosis may have prevented detection of cases outside the UK and highlights a need for greater standardisation. WGS was useful in targeting investigations, but greater coverage across Europe is needed to maximise its potential.

  18. 40 CFR 143.3 - Secondary maximum contaminant levels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Secondary maximum contaminant levels... levels. The secondary maximum contaminant levels for public water systems are as follows: Contaminant Level Aluminum 0.05 to 0.2 mg/l. Chloride 250 mg/l. Color 15 color units. Copper 1.0 mg/l. Corrosivity...

  19. Potential use of caprylic acid in broiler chickens: effect on Salmonella enteritidis.

    PubMed

    Skřivanová, Eva; Hovorková, Petra; Čermák, Ladislav; Marounek, Milan

    2015-01-01

    The effect of dietary caprylic acid (CA) on Salmonella Enteritidis, as well as the surface treatment of chicken skin contaminated with Salmonella Enteritidis was evaluated. To evaluate the dietary effect of CA on Salmonella Enteritidis, the individually housed broiler chickens (n=48) were divided into 4 groups (positive control, negative control, 2.5 g/kg of CA in the feed, and 5 g/kg of CA in the feed). The feed of all groups, except the negative control, was artificially contaminated with Salmonella Enteritidis ATCC 13076 (10(7) colony-forming units/100 g of feed). Both concentrations of dietary CA significantly decreased counts of Salmonella Enteritidis in the crop and cecum of experimental chickens (p<0.05). The effect of CA in the crop contents was more pronounced than in the cecum. Surface treatment of chilled chicken halves with CA at 1.25 and 2.5 mg/mL significantly decreased Salmonella Enteritidis contamination of chicken skin (p<0.05). The sensory evaluation of the skin and meat showed that treatment of the skin with 1.25 mg/mL of CA worsened odor and appearance of the chicken skin, while sensory traits of chicken meat were not significantly affected. Taste and overall acceptability was not influenced by CA in both meat and skin. Treatment of the skin with 2.5 mg/mL of CA resulted in more pronounced changes of the skin odor and appearance. In conclusion, dietary CA reduced carriage of Salmonella Enteritidis in chickens, whereas surface-treatment reduced or eliminated Salmonella Enteritidis contamination in the processed bird.

  20. Status of the ISS Trace Contaminant Control System

    NASA Technical Reports Server (NTRS)

    Macatangay, Ariel V.; Perry, Jay L.; Johnson, Sharon A.; Belcher, Paul A.

    2009-01-01

    A habitable atmosphere is a fundamental requirement for human spaceflight. To meet such a requirement, the cabin atmosphere must be constantly scrubbed to maintain human life and system functionality. The primary system for atmospheric scrubbing of the US on-orbit segment (USOS) of the International Space Station (ISS) is the Trace Contaminant Control System (TCCS). As part of the Environmental Control and Life Support Systems (ECLSS) atmosphere revitalization rack in the US Lab, the TCCS operates continuously, scrubbing trace contaminants generated primarily by two sources: the metabolic offgassing of crew members and the offgassing of equipment in the ISS. It has been online for approximately 95% since activated in February 2001. The TCCS is comprised of a charcoal bed, a catalytic oxidizer, and a lithium hydroxide post-sorbent bed, all of which are designed to be replaced onorbit when necessary. In 2006, all three beds were replaced following an observed increase in the system resistance that occurred over a period several months. The beds were returned to ground and subjected to a test, teardown and evaluation to investigate the root cause(s) of the decrease in flow rate through the system. In addition, various chemical and physical analyses of the bed materials were performed to determine contaminant loading and any changes in performance. This paper will mainly focus on the results of these analyses and how this correlates with what has been observed from archival sampling and onorbit events. This may provide insight into the future performance of the TCCS and rate of change for orbital replacement units in the TCCS.

  1. Identification of specific organic contaminants in different units of a chemical production site.

    PubMed

    Dsikowitzky, L; Botalova, O; al Sandouk-Lincke, N A; Schwarzbauer, J

    2014-07-01

    Due to the very limited number of studies dealing with the chemical composition of industrial wastewaters, many industrial organic contaminants still escape our view and consequently also our control. We present here the chemical characterization of wastewaters from different units of a chemical complex, thereby contributing to the characterization of industrial pollution sources. The chemicals produced in the investigated complex are widely and intensively used and the synthesis processes are common and applied worldwide. The chemical composition of untreated and treated wastewaters from the chemical complex was investigated by applying a non-target screening which allowed for the identification of 39 organic contaminants. According to their application most of them belonged to four groups: (i) unspecific educts or intermediates of industrial syntheses, (ii) chemicals for the manufacturing of pharmaceuticals, (iii) educts for the synthesis of polymers and resins, and (iv) compounds known as typical constituents of municipal sewage. A number of halogenated compounds with unknown toxicity and with very high molecular diversity belonged to the second group. Although these compounds were completely removed or degraded during wastewater treatment, they could be useful as "alarm indicators" for industrial accidents in pharmaceutical manufacturing units or for malfunctions of wastewater treatment plants. Three potential branch-specific indicators for polymer manufacturing were found in the outflow of the complex. Among all compounds, bisphenol A, which was present in the leachate water of the on-site waste deposit, occurred in the highest concentrations of up to 20 000 μg L(-1). The comparison of contaminant loads in the inflow and outflow of the on-site wastewater treatment facility showed that most contaminants were completely or at least significantly removed or degraded during the treatment, except two alkylthiols, which were enriched during the treatment process. The chemical composition of the inflow samples showed a very heterogenic composition and strongly varied, reflecting that large scale industrial synthesis is carried out in batches. The outflow contained mainly unspecific chlorinated educts or intermediates of industrial syntheses as well as compounds which are known as typical constituents of municipal wastewaters.

  2. The effect of infection-control barriers on the light intensity of light-cure units and depth of cure of composite.

    PubMed

    Hodson, Nicholas A; Dunne, Stephen M; Pankhurst, Caroline L

    2005-04-01

    Dental curing lights are vulnerable to contamination with oral fluids during routine intra-oral use. This controlled study aimed to evaluate whether or not disposable transparent barriers placed over the light-guide tip would affect light output intensity or the subsequent depth of cure of a composite restoration. The impact on light intensity emitted from high-, medium- and low-output light-cure units in the presence of two commercially available disposable infection-control barriers was evaluated against a no-barrier control. Power density measurements from the three intensity light-cure units were recorded with a radiometer, then converted to a digital image using an intra-oral camera and values determined using a commercial computer program. For each curing unit, the measurements were repeated on ten separate occasions with each barrier and the control. Depth of cure was evaluated using a scrape test in a natural tooth model. At each level of light output, the two disposable barriers produced a significant reduction in the mean power density readings compared to the no-barrier control (P<0.005). The cure sleeve inhibited light output to a greater extent than either the cling film or the control (P<0.005). Only composite restorations light-activated by the high level unit demonstrated a small but significant decrease in the depth of cure compared to the control (P<0.05). Placing disposable barriers over the light-guide tip reduced the light intensity from all three curing lights. There was no impact on depth of cure except for the high-output light, where a small decrease in cure depth was noted but this was not considered clinically significant. Disposable barriers can be recommended for use with light-cure lights.

  3. Evaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work

    PubMed Central

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    Background: A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean® technology, based on anodic oxidation. Method: The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean® (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. Results: After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean® was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. Discussion: An important factor for the efficacy of PotoClean® was the age of the units and their construction. For a new generation of dental units PotoClean® was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. Conclusion: The PotoClean® technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean® and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable. PMID:22558044

  4. Evaluation of the PotoClean(®) decontamination technology for reprocessing of water supply lines in dental units during routine work.

    PubMed

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.

  5. Breaking the Chain of Infection: Dental Unit Water Quality Control

    PubMed Central

    Pawar, Amrita; Mehta, Sonia; Dang, Rajat

    2016-01-01

    Introduction The air–water syringes, ultrasonic scalers, high speed air turbine handpieces are connected to dental units by a network of small-bore plastic tubes through which water and air travel to activate or cool the instruments and it had been shown that this system is extensively contaminated with microbial biofilms and pose a potential risk of infection for patients as well as dental professionals. Aim To evaluate and compare the efficacy of various disinfectants in reducing the microbial colony count in water derived from Dental Unit Waterlines. Materials and Methods Five random dental units were selected and samples were collected before and after intervention with 5 disinfectants (0.02% H2O2 continuously, 0.02% H2O2 continuously with shock treatment with 0.25% H2O2 weekly, 0.12% Chlorohexidine and 12% Ethanol overnight, 1:50 Original Listerine overnight, 2% Sodium Perborate and 2% EDTA 5 minutes in morning) using different disinfection methods for 4 weeks. Samples were cultured on Reasoner’s 2A (R2A) agar for microbial counting. Results Results were recorded as Colony forming units/ml (cfu/ml) and were evaluated statistically. Results showed that all the dental unit waterlines were heavily contaminated with microbes before any intervention. After 1 day of disinfection regime the counts reduced significantly and showed progressive reduction in consecutive weeks. Goals set by ADA & CDC were ultimately achieved at the end of 4 weeks. Conclusion All the disinfectants were equally effective in reducing the microbial colony count of DUWLs, irrespective of their concentration and method of disinfection. PMID:27630960

  6. Breaking the Chain of Infection: Dental Unit Water Quality Control.

    PubMed

    Pawar, Amrita; Garg, Sandeep; Mehta, Sonia; Dang, Rajat

    2016-07-01

    The air-water syringes, ultrasonic scalers, high speed air turbine handpieces are connected to dental units by a network of small-bore plastic tubes through which water and air travel to activate or cool the instruments and it had been shown that this system is extensively contaminated with microbial biofilms and pose a potential risk of infection for patients as well as dental professionals. To evaluate and compare the efficacy of various disinfectants in reducing the microbial colony count in water derived from Dental Unit Waterlines. Five random dental units were selected and samples were collected before and after intervention with 5 disinfectants (0.02% H2O2 continuously, 0.02% H2O2 continuously with shock treatment with 0.25% H2O2 weekly, 0.12% Chlorohexidine and 12% Ethanol overnight, 1:50 Original Listerine overnight, 2% Sodium Perborate and 2% EDTA 5 minutes in morning) using different disinfection methods for 4 weeks. Samples were cultured on Reasoner's 2A (R2A) agar for microbial counting. Results were recorded as Colony forming units/ml (cfu/ml) and were evaluated statistically. Results showed that all the dental unit waterlines were heavily contaminated with microbes before any intervention. After 1 day of disinfection regime the counts reduced significantly and showed progressive reduction in consecutive weeks. Goals set by ADA & CDC were ultimately achieved at the end of 4 weeks. All the disinfectants were equally effective in reducing the microbial colony count of DUWLs, irrespective of their concentration and method of disinfection.

  7. Analyzing the risk factors influencing surgical site infections: the site of environmental factors.

    PubMed

    Alfonso-Sanchez, Jose L; Martinez, Isabel M; Martín-Moreno, Jose M; González, Ricardo S; Botía, Francisco

    2017-06-01

    Addressing surgical site infection (SSI) is accomplished, in part, through studies that attempt to clarify the nature of many essential factors in the control of SSI. We sought to examine the link between multiple risk factors, including environmental factors, and SSI for prevention management. We conducted a longitudinal prospective study to identify SSIs in all patients who underwent interventions in 2014 in 8 selected hospitals on the Mediterranean coast of Spain. Risk factors related to the operating theatre included level of fungi and bacterial contamination, temperature and humidity, air renewal and differential air pressure. Patient-related variables included age, sex, comorbidity, nutrition level and transfusion. Other factors were antibiotic prophylaxis, electric versus manual shaving, American Society of Anaesthesiologists physical status classification, type of intervention, duration of the intervention and preoperative stay. Superficial SSI was most often associated with environmental factors, such as environmental contamination by fungi (from 2 colony-forming units) and bacteria as well as surface contamination. When there was no contamination in the operating room, no SSI was detected. Factors that determined deep and organ/space SSI were more often associated with patient characteristics (age, sex, transfusion, nasogastric feeding and nutrition, as measured by the level of albumin in the blood), type of intervention and preoperative stay. Antibiotic prophylaxis and shaving with electric razor were protective factors for both types of infection, whereas the duration of the intervention and the classification of the intervention as "dirty" were shared risk factors. Our results suggest the importance of environmental and surface contamination control to prevent SSI.

  8. Corrective Action Investigation Plan for Corrective Action Unit 410: Waste Disposal Trenches, Tonopah Test Range, Nevada, Revision 0 (includes ROTCs 1, 2, and 3)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NNSA /NV

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 410 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 410 is located on the Tonopah Test Range (TTR), which is included in the Nevada Test and Training Range (formerly the Nellis Air Force Range) approximately 140 miles northwest of Las Vegas, Nevada. This CAU is comprised of five Corrective Action Sites (CASs): TA-19-002-TAB2, Debris Mound; TA-21-003-TANL, Disposal Trench; TA-21-002-TAAL,more » Disposal Trench; 09-21-001-TA09, Disposal Trenches; 03-19-001, Waste Disposal Site. This CAU is being investigated because contaminants may be present in concentrations that could potentially pose a threat to human health and/or the environment, and waste may have been disposed of with out appropriate controls. Four out of five of these CASs are the result of weapons testing and disposal activities at the TTR, and they are grouped together for site closure based on the similarity of the sites (waste disposal sites and trenches). The fifth CAS, CAS 03-19-001, is a hydrocarbon spill related to activities in the area. This site is grouped with this CAU because of the location (TTR). Based on historical documentation and process know-ledge, vertical and lateral migration routes are possible for all CASs. Migration of contaminants may have occurred through transport by infiltration of precipitation through surface soil which serves as a driving force for downward migration of contaminants. Land-use scenarios limit future use of these CASs to industrial activities. The suspected contaminants of potential concern which have been identified are volatile organic compounds; semivolatile organic compounds; high explosives; radiological constituents including depleted uranium, beryllium, total petroleum hydrocarbons; and total Resource Conservation and Recovery Act metals. Field activities will consist of geophysical and radiological surveys, and collecting soil samples at biased locations by appropriate methods. A two-step data quality objective strategy will be followed: (1) define the nature of contamination at each CAS location by identifying any contamination above preliminary action levels (PALs); and, (2) determine the extent of contamination identified above PALs. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.« less

  9. Development and Testing of the Contaminant Insensitive Sublimator

    NASA Technical Reports Server (NTRS)

    Leimkuehler, Thomas O.; Stephan, Ryan A.

    2007-01-01

    Sublimators have been used for heat rejection for a variety of space applications including the Apollo Lunar Module and the Extravehicular Mobility Unit (EMU). Some of the attractive features of sublimators are that they are compact, lightweight, and self-regulating. One of the drawbacks of previous designs has been sensitivity to non-volatile contamination in the feedwater, which can clog relatively small pores (approx. 3-6 micrometers) in the porous plates where ice forms and sublimates. A new design that is less sensitive to contaminants is being developed at the Johnson Space Center (JSC). This paper describes the design, fabrication, and testing of the Contaminant Insensitive Sublimator (CIS) Engineering Development Unit (EDU).

  10. Field based plastic contamination sensing

    USDA-ARS?s Scientific Manuscript database

    The United States has a long-held reputation of being a dependable source of high quality, contaminant-free cotton. Recently, increased incidence of plastic contamination from sources such as shopping bags, vegetable mulch, surface irrigation tubing, and module covers has threatened the reputation o...

  11. SUMMARY OF WATERBORNE ILLNESS TRANSMITTED THROUGH CONTAMINATED GROUNDWATER

    EPA Science Inventory

    The use of contaminated, untreated or inadequately treated groundwater was responsible for 51 percent of all waterborne outbreaks and 40 percent of all waterborne illness reported in the United States during the period 1971-82. Contaminated, untreated or inadequately disinfected ...

  12. RCT: Module 2.07, Respiratory Protection, Course 8773

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    Internal dosimetry controls require the use of engineering controls to prevent the internal deposition of radioactive and nonradiological contaminants. However, when engineering and administrative controls are not available or feasible, respiratory protection may be necessary. The radiation control technician (RCT) should know and apply the considerations used in determining the respiratory protection equipment that is most appropriate for the job. The inappropriate use of or the use of the wrong respiratory protection equipment may result in undesirable health effects. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensivemore » Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.« less

  13. Determinant roles of environmental contamination and noncompliance with standard precautions in the risk of hepatitis C virus transmission in a hemodialysis unit.

    PubMed

    Girou, Emmanuelle; Chevaliez, Stéphane; Challine, Dominique; Thiessart, Michaël; Morice, Yoann; Lesprit, Philippe; Tkoub-Scheirlinck, Latifa; Soing-Altrach, Sophan; Cizeau, Florence; Cavin, Celine; André, Martine; Dahmanne, Djamel; Lang, Philippe; Pawlotsky, Jean-Michel

    2008-09-01

    Nosocomial transmission is the second most frequent cause of hepatitis C virus (HCV) infection. A prospective observational study was conducted to assess the roles of environmental contamination and noncompliance with standard precautions in HCV cross-transmission in a hemodialysis unit. Patients undergoing chronic hemodialysis in a French university hospital unit were systematically screened, revealing 2 sporadic cases of HCV transmission. An investigation was launched to determine whether the patients were infected in the hemodialysis unit and the possible roles of environmental contamination and noncompliance with standard precautions. We examined possible relationships among new cases of HCV infection, environmental contamination by blood and HCV RNA, and compliance with guidelines on hand hygiene and glove use. Two patients experienced seroconversion to HCV during the study period. Phylogenetic analyses showed that 1 of these patients was infected with the same strain as that affecting a chronically infected patient also treated in the unit. Of 740 environmental surface samples, 82 (11%) contained hemoglobin; 6 (7%) of those contained HCV RNA. The rate of compliance with hand hygiene was 37% (95% confidence interval, 35%-39%), and gloves were immediately removed after patient care in 33% (95% confidence interval, 29%-37%) of cases. A low ratio of nurses to patients and poor hand hygiene were independent predictors of the presence of hemoglobin on environmental surfaces. Blood-contaminated surfaces may be a source of HCV cross-transmission in a hemodialysis unit. Strict compliance with hand hygiene and glove use and strict organization of care procedures are needed to reduce the risk of HCV cross-transmission among patients undergoing hemodialysis.

  14. DEMONSTRATION BULLETIN: THE ECO LOGIC THERMAL DESORPTION UNIT - MIDDLEGROUND LANDFILL - BAY CITY, MI - ELI ECO LOGIC INTERNATIONAL, INC.

    EPA Science Inventory

    ECO Logic has developed a thermal desorption unit 0"DU) for the treatment of soils contaminated with hazardous organic contaminants. This TDU has been designed to be used in conjunction with Eco Logic's patented gas-phase chemical reduction reactor. The Eco Logic reactor is the s...

  15. Comparison of PCR/Electron Spray Ionization-Time-of-Flight-Mass Spectrometry versus Traditional Clinical Microbiology for Active Surveillance of Organisms Contaminating High-Use Surfaces in a Burn Intensive Care Unit, an Orthopedic Ward and Healthcare Workers

    DTIC Science & Technology

    2012-10-10

    were designed with anterooms and universal gowns and gloves are used) and ten from the orthopedic ward. Nine rooms in the burn ICU had sam- ple...PCR amplification was carried out as per Ecker et al [25]. The PCR products were then desalted in a 96-well plate format and sequentially electro...organisms by site. Based on these data, no obvious target for increased infection control efforts was seen in the study units. As this study was designed

  16. Testing of stack-unit/aquifer sensitivity analysis using contaminant plume distribution in the subsurface of Savannah River Site, South Carolina, USA

    USGS Publications Warehouse

    Rine, J.M.; Shafer, J.M.; Covington, E.; Berg, R.C.

    2006-01-01

    Published information on the correlation and field-testing of the technique of stack-unit/aquifer sensitivity mapping with documented subsurface contaminant plumes is rare. The inherent characteristic of stack-unit mapping, which makes it a superior technique to other analyses that amalgamate data, is the ability to deconstruct the sensitivity analysis on a unit-by-unit basis. An aquifer sensitivity map, delineating the relative sensitivity of the Crouch Branch aquifer of the Administrative/Manufacturing Area (A/M) at the Savannah River Site (SRS) in South Carolina, USA, incorporates six hydrostratigraphic units, surface soil units, and relevant hydrologic data. When this sensitivity map is compared with the distribution of the contaminant tetrachloroethylene (PCE), PCE is present within the Crouch Branch aquifer within an area classified as highly sensitive, even though the PCE was primarily released on the ground surface within areas classified with low aquifer sensitivity. This phenomenon is explained through analysis of the aquifer sensitivity map, the groundwater potentiometric surface maps, and the plume distributions within the area on a unit-by- unit basis. The results of this correlation show how the paths of the PCE plume are influenced by both the geology and the groundwater flow. ?? Springer-Verlag 2006.

  17. Monitoring radionuclide contamination in the unsaturated zone - Lessons learned at the Amargosa Desert Research Site, Nye County, Nevada

    USGS Publications Warehouse

    Stonestrom, David A.; Abraham, Jared D.; Andraski, Brian J.; Baker, Ronald J.; Mayers, C. Justin; Michel, Robert L.; Prudic, David E.; Striegl, Robert G.; Walvoord, Michelle Ann

    2004-01-01

    Contaminant-transport processes are being investigated at the U.S. Geological Survey’s Amargosa Desert Research Site (A DRS), adjacent to the Nation’s first commercial disposal facility for low-level radioactive waste. Gases containing tritium and radiocarbon are migrating through a 110-m thick unsaturated zone from unlined trenches that received waste from 1962 to 1992. Results relevant to long- term monitoring of radionuclides are summarized as follows. Contaminant plumes have unexpected histories and spatial configurations due to uncertainties in the: (1) geologic framework, (2) biochemical reactions involving waste components, (3) interactions between plume components and unsaturated-zone materials, (4) disposal practices, and (5) physical transport processes. Information on plume dynamics depends on ex-situ wet-chemical techniques because in-situ sensors for the radionuclides of interest do not exist. As at other radioactive-waste disposal facilities, radionuclides at the ADRS are mixed with varying amounts of volatile organic compounds (VOCs). Carbon-dioxide and VOC anomalies provide proxies for radioactive contamination. Contaminants in the unsaturated zone migrate along preferential pathways. Effective monitoring thus requires accurate geologic characterization. Direct- current electrical-resistivity imaging successfully mapped geologic units controlling preferential transport at the ADRS. Direct sampling of water from the unsaturated zone is complex and time consuming. Sampling plant water is an efficient alternative for mapping shallow tritium contamination.

  18. Detection of microbial contamination in platelets

    NASA Astrophysics Data System (ADS)

    Berg, Tracy L.; Leparc, German; Huffman, Debra E.; Gennaccaro, Angela L.; Garcia-Lopez, Alicia; Klungness, Greta; Stephans, Christie; Garcia-Rubio, Luis H.

    2005-03-01

    In the United States, approximately 100 patients develop fatal sepsis associated with platelet transfusions every year. Current culture methods take 24-48 hours to acquire results, which in turn decrease the shelf life of platelets. Many of the microorganisms that contaminate platelets can replicate easily at room temperature, which is the necessary storage temperature to keep platelets functional. Therefore, there is a need for in-situ quality control assessment of the platelet quality. For this purpose, a real time spectrophotometric technique has been developed. The Spectral Acquisition Processing Detection (SAPD) method, comprised of a UV-vis spectrophotometer and modeling algorithms, is a rapid method that can be performed prior to platelet transfusion to decrease the risk of bacterial infection to patients. The SAPD method has been used to determine changes in cell suspensions, based on size, shape, chemical composition and internal structure. Changes in these cell characteristics can in turn be used to determine microbial contamination, platelet aging and other physiologic changes. Detection limits of this method for platelet suspensions seeded with bacterial contaminants were identified to be less than 100 cfu/ml of sample. Bacterial counts below 1000 cfu/ml are not considered clinically significant. The SAPD method can provide real-time identification of bacterial contamination of platelets affording patients an increased level of safety without causing undue strain on laboratory budgets or personnel while increasing the time frame that platelets can be used by dramatically shortening contaminant detection time.

  19. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    PubMed

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  20. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-06-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary.

  1. Development of EPA Method 525.3 for the Analysis of Semivolatiles in Drinking Water

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) Office of Ground Water and Drinking Water (OGWDW) collects nationwide occurrence data on contaminants in drinking water using the Unregulated Contaminant Monitoring Regulations (UCMRs). The unregulated contaminants, which ar...

  2. Monitoring for Pesticides in Groundwater and Surface Water in Nevada, 2008

    USGS Publications Warehouse

    Thodal, Carl E.; Carpenter, Jon; Moses, Charles W.

    2009-01-01

    Commercial pesticide applicators, farmers, and homeowners apply about 1 billion pounds of pesticides annually to agricultural land, non-crop land, and urban areas throughout the United States (Gilliom and others, 2006, p. 1). The U.S. Environmental Protection Agency (USEPA) defines a pesticide as any substance used to kill or control insects, weeds, plant diseases, and other pest organisms. Although there are important benefits from the proper use of pesticides, like crop protection and prevention of human disease outbreaks, there are also risks. One risk is the contamination of groundwater and surface-water resources. Data collected during 1992-2001 from 51 major hydrologic systems across the United States indicate that one or more pesticide or pesticide breakdown product was detected in more than 50 percent of 5,057 shallow (less than 20 feet below land surface) wells and in all of the 186 stream sites that were sampled in agricultural and urban areas (Gilliom and others, 2006, p. 2-4). Pesticides can contaminate surface water and groundwater from both point sources and non-point sources. Point sources are from specific locations such as spill sites, disposal sites, pesticide drift during application, and application of pesticides to control aquatic pests. Non-point sources represent the dominant source of surface water and groundwater contamination and may include agricultural and urban runoff, erosion, leaching from application sites, and precipitation that has become contaminated by upwind applications. Pesticides typically enter surface water when rainfall or irrigation exceeds the infiltration capacity of soil and resulting runoff then transports pesticides to streams, rivers, and other surface-water bodies. Contamination of groundwater may result directly from spills near poorly sealed well heads and from pesticide applications through improperly designed or malfunctioning irrigation systems that also are used to apply pesticides (chemigation; Carpenter and Johnson, 1997). Groundwater contamination also may come indirectly by the percolation of agricultural and urban irrigation water through soil layers and into groundwater and from pesticide residue in surface water, such as drainage ditches, streams, and municipal wastewater. To protect surface water and groundwater from pesticide contamination, the USEPA requires that all states establish a pesticide management plan. The Nevada Department of Agriculture (NDOA), with assistance from the USEPA, developed a management program of education (Hefner and Donaldson, 2006), regulation (Johnson and others, 2006), and monitoring (Pennington and others, 2001) to protect Nevada's water resources from pesticide contaminants. Sampling sites are located in areas where urban or agricultural pesticide use may affect groundwater, water bodies, endangered species, and other aquatic life. Information gathered from these sites is used by NDOA to help make regulatory decisions that will protect human and environmental health by reducing and eliminating the occurrence of pesticide contamination. This fact sheet describes current (2008) pesticide monitoring of groundwater and streams by the NDOA in Nevada and supersedes Pennington and others (2001).

  3. Report on the remedial investigation of Bear Creek Valley at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 3: Appendix D -- Nature and extent of contamination report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-09-01

    This Remedial Investigation (RI) Report characterizes the nature and extent of contamination, evaluates the fate and transport of contaminants, and assesses risk to human health and the environment resulting from waste disposal and other US Department of Energy (DOE) operations in Bear Creek Valley (BCV). BCV, which is located within the DOE Oak Ridge Reservation (ORR) encompasses multiple waste units containing hazardous and radioactive wastes arising from operations at the adjacent Oak Ridge Y-12 Plant. The primary waste units discussed in this RI Report are the S-3 Site, Oil Landfarm (OLF), Boneyard/Burnyard (BYBY), Sanitary Landfill 1 (SL 1), and Bearmore » Creek Burial Grounds (BCBG). These waste units, plus the contaminated media resulting from environmental transport of the wastes from these units, are the subject of this RI. This BCV RI Report represents the first major step in the decision-making process for the BCV watershed. The RI results, in concert with the follow-on FS will form the basis for the Proposed Plan and Record of Decision for all BCV sites. This comprehensive decision document process will meet the objectives of the watershed approach for BCV. Appendix D describes the nature and extent of contamination in environmental media and wastes.« less

  4. Bacterial Community Diversity of Oil-Contaminated Soils Assessed by High Throughput Sequencing of 16S rRNA Genes.

    PubMed

    Peng, Mu; Zi, Xiaoxue; Wang, Qiuyu

    2015-09-24

    Soil bacteria play a major role in ecological and biodegradable function processes in oil-contaminated soils. Here, we assessed the bacterial diversity and changes therein in oil-contaminated soils exposed to different periods of oil pollution using 454 pyrosequencing of 16S rRNA genes. No less than 24,953 valid reads and 6246 operational taxonomic units (OTUs) were obtained from all five studied samples. OTU richness was relatively higher in contaminated soils than clean samples. Acidobacteria, Actinobacteria, Bacteroidetes, Chloroflexi, Planctomycetes and Proteobacteria were the dominant phyla among all the soil samples. The heatmap plot depicted the relative percentage of each bacterial family within each sample and clustered five samples into two groups. For the samples, bacteria in the soils varied at different periods of oil exposure. The oil pollution exerted strong selective pressure to propagate many potentially petroleum degrading bacteria. Redundancy analysis (RDA) indicated that organic matter was the highest determinant factor for explaining the variations in community compositions. This suggests that compared to clean soils, oil-polluted soils support more diverse bacterial communities and soil bacterial community shifts were mainly controlled by organic matter and exposure time. These results provide some useful information for bioremediation of petroleum contaminated soil in the future.

  5. Correlation of the Hubble Space Telescope (HST) Space Telescope Imaging Spectrometer (STIS) On-Orbit Data with Pre-launch Predictions and Ground Contamination Controls

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.

    2003-01-01

    The Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) was deployed on-orbit in February 1997. The contamination program for STIS was stringently controlled as the five-year end-of-life deposition was set at 158, per optical element. Contamination was controlled through materials selection, extensive vacuum outgassing certifications, cleaning techniques, and environmental controls. In addition to ground contamination controls, on-orbit contamination controls were implemented for both the HST servicing mission activities and early post-servicing mission checkout. The extensive contamination control program will be discussed and the STIS on-orbit data will be correlated with the prelaunch analytical predictions.

  6. Failure of bacterial screening to detect Staphylococcus aureus: the English experience of donor follow-up.

    PubMed

    Brailsford, S R; Tossell, J; Morrison, R; McDonald, C P; Pitt, T L

    2018-05-24

    Between February 2011 and December 2016, over 1·6 million platelet units, 36% pooled platelets, underwent bacterial screening prior to issue. Contamination rates for apheresis and pooled platelets were 0·02% and 0·07%, respectively. Staphylococcus aureus accounted for 21 contaminations, including four pooled platelets, one confirmed transfusion-transmitted infection (TTI) and three 'near-miss' incidents detected on visual inspection which were negative on screening. We describe follow-up investigations of 16 donors for skin carriage of S. aureus and molecular characterisation of donor and pack isolates. Units were screened by the BacT/ALERT 3D detection system. Contributing donors were interviewed and consent requested for skin and nasal swabbing. S. aureus isolates were referred for spa gene type and DNA macrorestriction profile to determine identity between carriage strains and packs. Donors of 10 apheresis and two pooled packs screen positive for S. aureus were confirmed as the source of contamination; seven had a history of skin conditions, predominantly eczema; 11 were nasal carriers. The 'near-miss' incidents were associated with apheresis donors, two donors harboured strains indistinguishable from the pack strain. The TTI was due to a screen-negative pooled unit, and a nasal isolate of one donor was indistinguishable from that in the unit. Staphylococcus aureus contamination is rare but potentially harmful in platelet units. Donor isolates showed almost universal correspondence in molecular type with pack isolates, thus confirming the source of contamination. The importance of visual inspection of packs prior to transfusion is underlined by the 'near-miss' incidents. © 2018 International Society of Blood Transfusion.

  7. Monitoring of Microscopic Filamentous Fungi in Indoor Air of Transplant Unit.

    PubMed

    Holý, Ondřej; Matoušková, Ivanka; Kubátová, Alena; Hamal, Petr; Svobodová, Lucie; Jurásková, Eva; Raida, Luděk

    2015-12-01

    The aim of the study was to control the microbial contamination of indoor air monitored monthly at the Transplant Unit of the University Hospital Olomouc from August 2010 to July 2011. The unit is equipped with a three-stage air filtration system with HEPA filters. The MAS-100 air sampler (Merck, GER) was used. Twenty locations were singled out for the purposes of collecting a total of 720 samplings of the indoor air. Swabs of the HVAC diffusers at the sampling locations were always carried out after the sampling of the indoor air. In total, 480 samples of the indoor air were taken for Sabouraud chloramphenicol agar. In 11 cases (2.29%) the cultivation verified the presence of microscopic filamentous fungi. Only two cases involved the sanitary facilities of a patient isolation box; the other positive findings were from the facilities. The most frequent established genus was Aspergillus spp. (4x), followed by Trichoderma spp. (2x) and Penicillium spp. (2x), Paecilomyces spp., Eurotium spp., and Chrysonilia spp. (1x each). In 2 cases the cultivation established sterile aerial mycelium, unfortunately no further identification was possible. A total of 726 swabs of HVAC diffusers were collected (2 positive-0.28%). The study results demonstrated the efficacy of the HVAC equipment. With the continuing increase in the number of severely immunocompromised patients, hospitals are faced with the growing problem of invasive aspergillosis and other opportunistic infections. Preventive monitoring of microbial air contaminants is of major importance for the control of invasive aspergillosis. Copyright© by the National Institute of Public Health, Prague 2015.

  8. New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: quality of blood components.

    PubMed

    Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A

    2014-10-01

    TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.

  9. Microlith-Based Catalytic Reactor for Air Quality and Trace Contaminant Control Applications

    NASA Technical Reports Server (NTRS)

    Vilekar, Saurabh; Hawley, Kyle; Junaedi, Christian; Crowder, Bruce; Prada, Julian; Mastanduno, Richard; Perry, Jay L.; Kayatin, Matthew J.

    2015-01-01

    Traditionally, gaseous compounds such as methane, carbon monoxide, and trace contaminants have posed challenges for maintaining clean air in enclosed spaces such as crewed spacecraft cabins as they are hazardous to humans and are often difficult to remove by conventional adsorption technology. Catalytic oxidizers have provided a reliable and robust means of disposing of even trace levels of these compounds by converting them into carbon dioxide and water. Precision Combustion, Inc. (PCI) and NASA - Marshall (MSFC) have been developing, characterizing, and optimizing high temperature catalytic oxidizers (HTCO) based on PCI's patented Microlith® technology to meet the requirements of future extended human spaceflight explorations. Current efforts have focused on integrating the HTCO unit with a compact, simple recuperative heat exchanger to reduce the overall system size and weight while also reducing its energy requirements. Previous efforts relied on external heat exchangers to recover the waste heat and recycle it to the oxidizer to minimize the system's power requirements; however, these units contribute weight and volume burdens to the overall system. They also result in excess heat loss due to the separation of the HTCO and the heat recuperator, resulting in lower overall efficiency. Improvements in the recuperative efficiency and close coupling of HTCO and heat recuperator lead to reductions in system energy requirements and startup time. Results from testing HTCO units integrated with heat recuperators at a variety of scales for cabin air quality control and heat melt compactor applications are reported and their benefits over previous iterations of the HTCO and heat recuperator assembly are quantified in this paper.

  10. Initially unrecognized distribution of a commercially cooked meat product contaminated over several months with Salmonella serotype Infantis.

    PubMed

    Kohl, K S; Farley, T A

    2000-12-01

    An outbreak of salmonellosis occurred among 63 wedding participants. The outbreak was investigated through cohort, laboratory, and environmental studies. Consumption of rice-dressing made from a commercially cooked, meat-based, rice-dressing mix was strongly associated with illness. Nineteen patient isolates, six company/grocery store isolates cultured from the rice-dressing mix, and one environmental isolate from a pump in the production line were of an identical outbreak strain of Salmonella Infantis characterized by pulsed-field gel electrophoresis. In the production line, cooked rice-dressing mix tested negative for S. Infantis before and positive after contact with the contaminated pump. The dressing-mix had an estimated 200 colony-forming units of salmonella per gram of product, and > 180,000 pounds were distributed in 9 states for > or = 2 months before contamination was recognized. Food manufacturers should be required to use systematic, hazard analysis critical control point risk management practices for all processed meat products, validated by periodic microbiologic monitoring of the end product.

  11. Superfund Record of Decision (EPA Region 5): Fields Brook sediment operable unit, Ashtabula, Ohio, September 1986. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-09-30

    Fields Brook is located in the City of Ashtabula, Ohio and drains a 5.6-square mile watershed (defined as the 'site'). The 3.5 mile main channel of Fields Brook flows through an industrial area that is one of the largest and most diversified concentrations of chemical plants in Ohio. Industrial sources have contaminated the sediment in Fields Brook with a variety of organic and heavy metal pollutants, including TCE, PCE, chlorobenzene, vinyl chloride, arsenic, zinc, mercury and chromium. Base-neutral compounds including hexachloroethane, toluenediamine and toluene diisocyanate also were detected in Fields Brook sediments. Sediments taken from the Ashtabula River in themore » vicinity of Fields Brook are contaminated with PCBs. The U.S. EPA believes that the amount of contamination entering the brook at this time has been substantially reduced due to the recent development of pollution control laws and discharge-permitting requirements.« less

  12. Enhanced bioremediation of lead-contaminated soil by Solanum nigrum L. with Mucor circinelloides.

    PubMed

    Sun, Liqun; Cao, Xiufeng; Li, Min; Zhang, Xu; Li, Xinxin; Cui, Zhaojie

    2017-04-01

    Strain selected from mine tailings in Anshan for Pb bioremediation was characterized at the genetic level by internal transcribed spacer (ITS) sequencing. Results revealed that the strain belongs to Mucor circinelloides. Bioremediation of lead-contaminated soil was conducted using Solanum nigrum L. combined with M. circinelloides. The removal efficacy was in the order microbial/phytoremediation > phytoremediation > microbial remediation > control. The bioremediation rates were 58.6, 47.2, and 40.2% in microbial/phytoremediation, microbial remediation, and phytoremediation groups, respectively. Inoculating soil with M. circinelloides enhanced Pb removal and S. nigrum L. growth. The bioaccumulation factor (BF, 1.43), enrichment factor (EF, 1.56), and translocation factor (TF, 1.35) were higher than unit, suggesting an efficient ability of S. nigrum L. in Pb bioremediation. Soil fertility was increased after bioremediation according to change in enzyme activities. The results indicated that inoculating S. nigrum L. with M. circinelloides enhanced its efficiency for phytoremediation of soil contaminated with Pb.

  13. Corrective Action Investigation Plan for Corrective Action Unit 573: Alpha Contaminated Sites, Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick

    2014-05-01

    Corrective Action Unit (CAU) 573 is located in Area 5 of the Nevada National Security Site, which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 573 is a grouping of sites where there has been a suspected release of contamination associated with non-nuclear experiments and nuclear testing. This document describes the planned investigation of CAU 573, which comprises the following corrective action sites (CASs): • 05-23-02, GMX Alpha Contaminated Area • 05-45-01, Atmospheric Test Site - Hamilton These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate andmore » recommend corrective action alternatives.« less

  14. Payload/orbiter contamination control requirement study

    NASA Technical Reports Server (NTRS)

    Bareiss, L. E.; Ress, E. B.

    1975-01-01

    The results of a contamination impact analysis upon the spacelab carrier and the spacelab carrier upon some of its potential payloads are presented. These results are based upon contamination computer modeling techniques developed to predict the induced environment for spacelab and to provide the basis for evaluation of the predicted environment against the current on orbit contamination control criteria as specified for payloads. Those spacelab carrier contamination sources evaluated against the stated contamination control criteria were outgassing/offgassing of the major nonmetallic thermal control coating of the spacelab carriers, spacelab core and experiment module and tunnel cabin atmosphere leakage, avionics bay vent, spacelab condensate vent, random particulate sloughing, and the return flux of the molecular content of these sources from the gas-gas interactions with the ambient orbital environment. It is indicated that the spacelab carrier can meet the intent of the contamination control criteria through incorporating known contamination control practices.

  15. 30 CFR 56.5005 - Control of exposure to airborne contaminants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control of exposure to airborne contaminants... Air Quality and Physical Agents Air Quality § 56.5005 Control of exposure to airborne contaminants. Control of employee exposure to harmful airborne contaminants shall be, insofar as feasible, by prevention...

  16. [Analysis of main risk factors causing foodborne diseases in food catering business].

    PubMed

    Fan, Yong-xiang; Liu, Xiu-mei; Bao, Yi-dan

    2011-06-01

    To study main risk factors that cause foodborne diseases in food catering business. Data from references and investigations conducted in food catering units were used to establish models which based on @Risk 4.5 with Monte Carlo method referring to food handling practice model (FHPM) to make risk assessment on factors of food contamination in food catering units. The Beta-Poisson models on dose-response relationship to Salmonella (developed by WHO/FAO and United States Department of Agriculture) and Vibrio parahaemolyticus (developed by US FDA) were used in this article to analyze the dose-response relationship of pathogens. The average probability of food poisoning by consuming Salmonella contaminated cooked meat under refrigeration was 1.96 × 10(-4) which was 1/2800 of the food under non-refrigeration (the average probability of food poisoning was 0.35 at room temperature 25°C). The average probability by consuming 6 hours stored meat under room temperature was 0.11 which was 16 times of 2 hours storage (6.79 × 10(-3)). The average probability by consuming contaminated meat without fully cooking was 1.71 × 10(-4) which was 100 times of consuming fully cooked meat (1.88 × 10(-6)). The probability growth of food poisoning by consuming Vibrio parahaemolyticus contaminated fresh seafood was proportional with contamination level and prevalence. The primary contamination level, storage temperature and time, cooking process and cross contamination are important factors of catering food safety.

  17. Superfund Record of Decision (EPA Region 8): Ogden Defense Depot, Operable Unit 1, Weber County, UT. (Second remedial action), June 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-26

    Since 1941, the 1,100-acre Ogden Defense Depot (DDOU) site, located in Ogden, Weber County, Utah, has been a key installation in the Department of Defense supply system. Operable Unit 1, which is located in the southwest part of the DDOU, is composed of the backfill material in the Plain City Canal, Burial Site 1, and Burial Site 3-B. Burial Site 1 was reported to have been used for the disposal of riot control agent (chloroacetophenone) and white smoke (hexachloroethane) containers in the 1940's. In the early 1960's, Burial Site 3-B was reportedly the burying ground for over 1,000 arctic-style rubbermore » boots. The ROD addresses a final remedy for OU1 that will reduce the principal threats posed by contaminated soil and shallow ground water at the site. The primary contaminants of concern affecting the soil, debris, and ground water are VOCs, including TCE; other organics, including dioxins and pesticides; and metals, including arsenic and lead.« less

  18. An IDEA of What's in the Air

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Automatic Particle Fallout Monitor (APFM) is an automated instrument that assesses real-time particle contamination levels in a facility by directly imaging, sizing, and counting contamination particles. It allows personnel to respond to particle contamination before it becomes a major problem. For NASA, the APFM improves the ability to mitigate, avoid, and explain mission-compromising incidents of contamination occurring during payload processing, launch vehicle ground processing, and potentially, during flight operations. Commercial applications are in semiconductor processing and electronics fabrication, as well as aerospace, aeronautical, and medical industries. The product could also be used to measure the air quality of hotels, apartment complexes, and corporate buildings. IDEA sold and delivered its first four units to the United Space Alliance for the Space Shuttle Program at Kennedy. NASA used the APFM in the Kennedy Space Station Processing Facility to monitor contamination levels during the assembly of International Space Station components.

  19. USING A HEAT PULSE TO MEASURE THE FLUX BETWEEN GROUNDWATER AND SURFACE WATER

    EPA Science Inventory

    EPA estimates that 10 percent of the sediments under the surface waters of the United States are contaminated and approximately 20 percent of the superfund sites include contaminated sediments. The risk associated with these contaminated sediments is directly related to the flux...

  20. Metrics for Nitrate Contamination of Ground Water at CAFO Land Application Site - Iowa Swine Study

    EPA Science Inventory

    Nitrate (NO3-) is the most common chemical contaminant found in ground water and there are increasing indications that agriculture contributes to this contamination. In the United States, concentrated animal feeding operations (CAFO) are a common agricultural practice. CAFO lea...

  1. Adsorption of Ammonia on Regenerable Carbon Sorbents

    NASA Technical Reports Server (NTRS)

    Wójtowicz, Marek A.; Cosgrove, Jesph E.; Serio, Michael A..; Wilburn, Monique

    2015-01-01

    Results are presented on the development of reversible sorbents for the combined carbon dioxide, moisture, and trace-contaminant (TC) removal for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The currently available life support systems use separate units for carbon dioxide, trace contaminants, and moisture control, and the long-term objective is to replace the above three modules with a single one. Data on sorption and desorption of ammonia, which is a major TC of concern, are presented in this paper. The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is non-regenerable, and the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. In this study, several carbon sorbents were fabricated and tested for ammonia sorption. Ammonia-sorption capacity was related to carbon pore structure characteristics, and the temperature of oxidative carbon-surface treatment was optimized for enhanced ammonia-sorption performance.

  2. Analysis of the Ability of United States and Russian Trace Contaminant Control Systems to Meet U.S. 180-Day and Russian 360-Day Spacecraft Maximum Allowable Concentrations

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2016-01-01

    As the Space Station Freedom program transitioned to become the International Space Station (ISS), uncertainty existed concerning the performance capabilities for U.S.- and Russian-provided trace contaminant control (TCC) equipment. In preparation for the first dialogue between NASA and Russian Space Agency personnel in Moscow, Russia, in late April 1994, an engineering analysis was conducted to serve as a basis for discussing TCC equipment engineering assumptions as well as relevant assumptions on equipment offgassing and cabin air quality standards. The analysis presented was conducted as part of the efforts to integrate Russia into the ISS program via the early ISS Multilateral Medical Operations Panel's Air Quality Subgroup deliberations. This analysis, served as a basis for technical deliberations that established a framework for TCC system design and operations among the ISS program's international partners that has been instrumental in successfully managing the ISS common cabin environment.

  3. Adsorption of Carbon Dioxide, Ammonia, Formaldehyde, and Water Vapor on Regenerable Carbon Sorbents

    NASA Technical Reports Server (NTRS)

    Wojtowicz, Marek A.; Cosgrove, Joseph E.; Serio, Michael A.; Wilburn, Monique

    2015-01-01

    Results are presented on the development of reversible sorbents for the combined carbon dioxide, moisture, and trace-contaminant (TC) removal for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The currently available life support systems use separate units for carbon dioxide, trace contaminants, and moisture control, and the long-term objective is to replace the above three modules with a single one. Furthermore, the current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is nonregenerable, and the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. In this study, several carbon sorbents were fabricated and tested for simultaneous carbon dioxide, ammonia, formaldehyde, and water sorption. Multiple adsorption/vacuum-regeneration cycles were demonstrated at room temperature, and also the enhancement of formaldehyde sorption by the presence of ammonia in the gas mixture.

  4. Outbreaks attributed to fresh leafy vegetables, United States, 1973–2012

    PubMed Central

    HERMAN, K. M.; HALL, A. J.; GOULD, L. H.

    2015-01-01

    SUMMARY Leafy vegetables are an essential component of a healthy diet; however, they have been associated with high-profile outbreaks causing severe illnesses. We reviewed leafy vegetable-associated outbreaks reported to the Centers for Disease Control and Prevention between 1973 and 2012. During the study period, 606 leafy vegetable-associated outbreaks, with 20 003 associated illnesses, 1030 hospitalizations, and 19 deaths were reported. On average, leafy vegetable-associated outbreaks were larger than those attributed to other food types. The pathogens that most often caused leafy vegetable-associated outbreaks were norovirus (55% of outbreaks with confirmed aetiology), Shiga toxin-producing Escherichia coli (STEC) (18%), and Salmonella (11%). Most outbreaks were attributed to food prepared in a restaurant or catering facility (85%). An ill food worker was implicated as the source of contamination in 31% of outbreaks. Efforts by local, state, and federal agencies to control leafy vegetable contamination and outbreaks should span from the point of harvest to the point of preparation. PMID:25697407

  5. Comparison of bacterial counts in expressed breast milk following standard or strict infection control regimens in neonatal intensive care units: compliance of mothers does matter.

    PubMed

    Haiden, N; Pimpel, B; Assadian, O; Binder, C; Kreissl, A; Repa, A; Thanhäuser, M; Roberts, C D; Berger, A

    2016-03-01

    Bacterial counts in 1466 expressed breast milk (EBM) samples from women following one of two infection control regimens (standard vs strict) were investigated. Overall, 12% of samples yielded Gram-negative bacteria, with no significant differences between the standard [11.9% (94/788)] and strict [12.1% (82/678)] regimens (P = 0.92). Significantly more samples were contaminated when expressed at home (standard regimen home/hospital: 17.9% vs 6.1%; strict regimen home/hospital: 19.6% vs 3.4%; P < 0.001). Bacterial contamination of EBM was not associated with the regimen, but was associated with the location of breast milk expression. Attempts to improve personal hygiene during milk collection seem to be of limited value. Good hygiene of collection and storage equipment is likely to be the most important way to ensure the microbiological quality of EBM. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Outbreaks attributed to fresh leafy vegetables, United States, 1973-2012.

    PubMed

    Herman, K M; Hall, A J; Gould, L H

    2015-10-01

    Leafy vegetables are an essential component of a healthy diet; however, they have been associated with high-profile outbreaks causing severe illnesses. We reviewed leafy vegetable-associated outbreaks reported to the Centers for Disease Control and Prevention between 1973 and 2012. During the study period, 606 leafy vegetable-associated outbreaks, with 20 003 associated illnesses, 1030 hospitalizations, and 19 deaths were reported. On average, leafy vegetable-associated outbreaks were larger than those attributed to other food types. The pathogens that most often caused leafy vegetable-associated outbreaks were norovirus (55% of outbreaks with confirmed aetiology), Shiga toxin-producing Escherichia coli (STEC) (18%), and Salmonella (11%). Most outbreaks were attributed to food prepared in a restaurant or catering facility (85%). An ill food worker was implicated as the source of contamination in 31% of outbreaks. Efforts by local, state, and federal agencies to control leafy vegetable contamination and outbreaks should span from the point of harvest to the point of preparation.

  7. Success of the Melton Valley Watershed Remediation at the ORNL - 12351

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adler, David; Wilkerson, Laura; Sims, Lynn

    2012-07-01

    The source remediation of the Melton Valley (MV) Watershed at the U.S. Department of Energy's (DOE's) Oak Ridge National Laboratory was completed 5 years ago (September 2006). Historic operations at the laboratory had resulted in chemical and radionuclide contaminant releases and potential risks or hazards within 175 contaminated units scattered across an area of 430 hectares (1062 acres) within the watershed. Contaminated areas included burial grounds, landfills, underground tanks, surface impoundments, liquid disposal pit/trenches, hydrofracture wells, leak and spill spites, inactive surface structures, and contaminated soil and sediments. The remediation of the watershed was detailed in the MV Interim Actionmore » Record of Decision (ROD) and included a combination of actions encompassing containment, isolation, stabilization, removal, and treatment of sources within the watershed and established the monitoring and land use controls that would result in protection of human health. The actions would take place over 5 years with an expenditure of over $340 M. The MV remedial actions left hazardous wastes in-place (e.g., buried wastes beneath hydraulic isolation caps) and cleanup at levels that do not allow for unrestricted access and unlimited exposure. The cleanup with the resultant land use would result in a comprehensive monitoring plan for groundwater, surface water, and biological media, as well as the tracking of the land use controls to assure their completion. This paper includes an overview of select performance measures and monitoring results, as detailed in the annual Remediation Effectiveness Report and the Five-Year Report. (authors)« less

  8. Antimicrobial capacity of Aloe vera and propolis dentifrice against Streptococcus mutans strains in toothbrushes: an in vitro study.

    PubMed

    Bertolini, Patrícia Fernanda Roesler; Biondi Filho, Oswaldo; Pomilio, Arnaldo; Pinheiro, Sérgio Luiz; Carvalho, Meghi Silva de

    2012-02-01

    This study evaluated in vitro the efficiency of Aloe vera and propolis dentifrice on reducing the contamination of toothbrush bristles by a standard strain of Streptococcus mutans (ATCC 25175; SM), after toothbrushing. Fifteen sterile toothbrushes were randomly divided into 5 toothbrushing groups: I (negative control): without dentifrice; II: with fluoridated dentifrice; III: with triclosan and gantrez dentifrice; IV (positive control): without dentifrice and irrigation with 10 mL of 0.12% chlorhexidine gluconate; V: with Aloe vera and propolis dentifrice. In each group, 1 sterile bovine tooth was brushed for 1 min, where the toothbrush bristles were contaminated with 25 µL of SM. After toothbrushing, the bristles were stored in individual test tubes with 3 mL of BHI under anaerobiosis of 37°C for 48 h. Then, they were seeded with sterile swab in triplicate in the Mitis salivarius - Bacitracin culture medium. The samples were kept under anaerobiosis of 37°C for 48 h. Scores were used to count the number of colony forming units (cfu). The results were submitted to the Mann-Whitney statistical test at 5% significance level. There was statistically significant difference (p<0.05) for the reduction of bristle contamination comparing groups II, III, IV and V to group I. It may be stated that after toothbrushing, the Aloe vera and propolis dentifrice reduced the contamination of toothbrush bristles by SM, without differentiation from the other chemical agents used.

  9. 10 CFR 835.1101 - Control of material and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....1101 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Radioactive Contamination Control... section, material and equipment in contamination areas, high contamination areas, and airborne radioactivity areas shall not be released to a controlled area if: (1) Removable surface contamination levels on...

  10. Engineering Technical Support Center Annual Report Fiscal ...

    EPA Pesticide Factsheets

    The United States Environmental Protection Agency (EPA or Agency) Office of Research and Development (ORD) created the Engineering Technical Support Center (ETSC) in 1987, one of several technical support centers created as part of the Technical Support Project (TSP). ETSC provides engineering expertise to Agency program and regional offices and remediation teams working at contaminated sites across the country. The ETSC is operated within ORD’s Land Remediation and Pollution Control Division (LRPCD) of the National Risk Management Research Laboratory (NRMRL) in Cincinnati, Ohio. The ETSC’s mission is to provide site-specific scientific and engineering technical support to Remedial Project Managers, On-Scene Coordinators, and other remediation personnel at contaminated sites. This allows local, regional, or national authorities to work more quickly, efficiently, and cost effectively, while also increasing the technical experience of the remediation team. Since its inception, the ETSC has supported countless projects across all EPA Regions in almost all states and territories. This report highlights significant projects the ETSC supported in fiscal year 2015 (FY15). These projects addressed an array of environmental scenarios, such as remote mining contamination, expansive landfill waste, cumulative impacts from multiple contamination sources, and persistent threats from abandoned industrial sites. Constructing and testing new and innovative treatment technol

  11. Inorganic pollution around the Qinghai-Tibet Plateau: An overview of the current observations.

    PubMed

    Wu, Jun; Duan, Dongping; Lu, Jian; Luo, Yongming; Wen, Xiaohu; Guo, Xiaoying; Boman, Brian J

    2016-04-15

    The Qinghai-Tibet Plateau is the highest geographical unit in the world. Thus, it serves an important role in evaluating long-term ecologic conditions and environmental status and changes over time. This study summarizes major and trace element concentrations in biota and in water and soil. It also pays attention to gaseous pollutant and particle concentrations in air around the Qinghai-Tibet Plateau. The degree of soil heavy metal contamination and the water heavy metal hazard index were respectively evaluated. The contamination degrees of two sampling areas around the Qinghai-Tibet Plateau reached extremely high levels with soil mCd (modified degree of contamination) values exceeding 20. Surprisingly, over 54% of sampling areas showed moderate or more serious soil contamination degree (mCd>1.5). Moreover, the hazard indexes of two important rivers were 1.56 and 7.59, reaching unacceptable level. The potential risk might be beyond our expectation. Therefore, it should be an urgent and top priority to identify and confirm possible pollution sources around the Qinghai-Tibet Plateau. Then, it is imperative to implement feasible and effective environmental quality control strategies. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. High Occurrence Rate and Contamination Level of Bacillus cereus in Organic Vegetables on Sale in Retail Markets.

    PubMed

    Kim, Young-Ji; Kim, Hong-Seok; Kim, Kwang-Yeop; Chon, Jung-Whan; Kim, Dong-Hyeon; Seo, Kun-Ho

    2016-12-01

    Organic foods have risen in popularity recently. However, the increased risk of bacterial contamination of organic foods has not been fully evaluated. In this study, 100 samples each of organic and conventional fresh vegetables (55 lettuce samples and 45 sprout samples) sold in South Korea were analyzed for aerobic bacteria, coliforms, Escherichia coli, and Bacillus cereus. Although the aerobic bacteria and coliform counts were not significantly different between the two farming types (p > 0.05), the occurrence rate of B. cereus was higher in organically cultivated vegetables compared with those grown conventionally (70% vs. 30%, respectively). The mean contamination level of B. cereus-positive organic samples was also significantly higher (1.86 log colony-forming unit [CFU]/g vs. 0.69 log CFU/g, respectively) (p < 0.05). In addition, six samples of organic vegetables were found to be contaminated with B. cereus at over 4 log CFU/g categorized as unsatisfactory according to Health Protection Agency guideline. The relatively higher occurrence rate of B. cereus in organic vegetables emphasizes the importance of implementing control measures in organic vegetable production and postharvest processing to reduce the risk of food poisoning.

  13. Human health risks due to consumption of chemically contaminated fishery products.

    PubMed Central

    Ahmed, F E; Hattis, D; Wolke, R E; Steinman, D

    1993-01-01

    A small proportion of fishery products contaminated with appreciable amounts of potentially hazardous inorganic and organic contaminants from natural and environmental sources seem to pose the greatest potential for toxicity to consumers of fishery products in the United States. Health risks due to chemicals (e.g., modest changes in the overall risk of cancer, subtle deficits of neurological development in fetuses and children) are difficult to measure directly in people exposed to low levels. Immunocompetence may increase cancer risk. Inferences about the potential magnitude of these problems must be based on the levels of specific chemical present, observations of human populations and experimental animals exposed to relatively high doses, and theories about the likely mechanisms of action of specific intoxicants and the population distribution of sensitivity of human exposure. Lognormal distributions were found to provide good descriptions of the pattern of variation of contaminant concentrations among different species and geographic areas; this variability offers a solution for reduction of exposure through restricting harvest of aquatic animals from certain sites and by excluding certain species. Available information suggest that risks are not generally of high magnitude; nevertheless, their control will significantly improve public health.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8143635

  14. HIGH BREAST MILK LEVELS OF POLYCHLORINATEDE BIPHENYLS (PCBS) AMONG FOUR WOMEN LIVING ADJACENT TO A PCB-CONTAMINATED WASTE SITE

    EPA Science Inventory

    As a consequence of contamination by effluents from local electronics manufacturing facilities, the New Bedford Harbor and estuary in southeastern Massachusetts is among the sites in the United States that are considered the most highly contaminated by polychlorinated biphenyls (...

  15. National water summary 1983: Hydrologic events and issues

    USGS Publications Warehouse

    ,

    1984-01-01

    The United States as a Nation possesses abundant water resources and has developed and used those resources extensively. The national renewable supply of water is about 1,400 billion gallons per day (for the conterminous 48 States). Approximately 380 billion gallons per day of freshwater is withdrawn for use by the Nation's homes, farms, and industries, and about 280 billion gallons per day is returned to streams. Although a large percentage of the Nation's waste is carried in this return flow, the quality of water in streams has improved in many respects as a result of the pollution-control pro- grams of recent years. However, much remains to be learned about water quality particularly the extent of contamination by synthetic organic chemicals and heavy metals, and the effects of these contaminants on human health.

  16. Evaluation of diminished microbial contamination in handling of a novel daily disposable flat pack contact lens.

    PubMed

    Nomachi, Miya; Sakanishi, Kotaro; Ichijima, Hideji; Cavanagh, H Dwight

    2013-05-01

    To evaluate the efficacy of a novel daily disposable (DD) flat package in regard to microbial contamination on the anterior and posterior surfaces of a contact lens (CL) during handling of the lens for insertion. Four kinds of commercially available general blister-packed daily disposable contact lenses (DD CLs) as controls and a novel Magic 1-day Menicon Flat Pack as a test lens were used for this in vitro study. Lenses were removed from their packages using fingers coated with fluorescein 3 to 5 μm beads or an approximately 7×10(2) to 2×10(3) colony-forming unit (CFU)/mL Staphylococcus aureus suspension. The transfer of fluorescein beads to the surface of the lenses was then observed by fluorescence microscopy. Microbial contamination on the lenses was observed by light microscopy after a 2-day incubation period; and, the number of colonies isolated from the contaminated lenses was determined after 4 days of incubation. The number of fluorescein beads on the Magic lens was significantly less (p<0.05) than that of the general blister-packed control lenses. Adherence of microbial colonies was observed on both inner and outer surfaces of general blister-packed lenses, whereas no colony formation was found on the inner surface of the Magic lens, and the lowest bacterial adherence was observed for the Magic lens. The data demonstrated that placement of the Magic DD lens onto the eye is accompanied by diminished microbial contamination compared with general blister-packed DD CLs. Eye care professionals; however, should instruct patients to comply with intended use of DD CLs to prevent CL-associated microbial keratitis. In all cases, hand washing is mandated prelens insertion.

  17. Evaluation of the Efficacy of Disinfectant Footmats for the Reduction of Bacterial Contamination on Footwear in a Large Animal Veterinary Hospital.

    PubMed

    Hornig, K J; Burgess, B A; Saklou, N T; Johnson, V; Malmlov, A; Van Metre, D C; Morley, P S; Byers, S R

    2016-11-01

    Infection control is critical to providing high-quality patient care. Many veterinary teaching hospitals (VTHs) utilize footbaths or footmats at entrances and key control points throughout the facility to decrease trafficking of pathogenic microorganism on contaminated footwear. To compare efficacy of 4 disinfectants used in footmats for decreasing bacterial contamination of footwear in a large animal hospital. A single adult dairy cow was housed in a stall for 4 days to facilitate stall contamination with fecal material. Overboots were experimentally contaminated with organic material in a standardized manner. Each boot was randomly assigned to 1 of 5 treatments (no treatment, or exposure to 1 of 4 disinfectants: an accelerated peroxygen [AHP], a peroxygen [VIRKON], a quaternary ammonium [QUAT], and a phenolic disinfectant [PHENOLIC]) by stepping on a soaked footmat and collecting samples from boot soles. Generalized linear modeling was used to analyze differences in bacterial counts. Reductions in colony-forming units (CFUs) on treated boots ranged from no detectable reduction to 0.45 log 10 and varied by disinfectant. Percentage reductions in total bacterial counts generally were larger (albeit still modest) for AHP and QUAT disinfectants (range 37-45%) and smallest for the PHENOLIC (no detectable reduction). In general, use of disinfectant footmats was associated with significant reductions in viable bacteria on overboots-albeit with variable efficacy. Footmats may be useful adjuncts to cleaning and disinfection programs for decreasing trafficking of microorganisms throughout VTHs but should not be considered as a sole prevention method. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  18. Decreasing airborne contamination levels in high-risk hospital areas using a novel mobile air-treatment unit.

    PubMed

    Bergeron, V; Reboux, G; Poirot, J L; Laudinet, N

    2007-10-01

    To evaluate the performance of a new mobile air-treatment unit that uses nonthermal-plasma reactors for lowering the airborne bioburden in critical hospital environments and reducing the risk of nosocomial infection due to opportunistic airborne pathogens, such as Aspergillus fumigatus. Tests were conducted in 2 different high-risk hospital areas: an operating room under simulated conditions and rooms hosting patients in a pediatric hematology ward. Operating room testing provided performance evaluations of removal rates for airborne contamination (ie, particles larger than 0.5 microm) and overall lowering of the airborne bioburden (ie, colony-forming units of total mesophilic flora and fungal flora per cubic meter of air). In the hematology service, opportunistic and nonpathogenic airborne fungal levels in a patient's room equipped with an air-treatment unit were compared to those in a control room. In an operating room with a volume of 118 m(3), the time required to lower the concentration of airborne particles larger than 0.5 microm by 90% was decreased from 12 minutes with the existing high-efficiency particulate air filtration system to less than 2 minutes with the units tested, with a 2-log decrease in the steady-state levels of such particles (P<.01). Concurrently, total airborne mesophilic flora concentrations dropped by a factor of 2, and the concentrations of fungal species were reduced to undetectable levels (P<.01). The 12-day test period in the hematology ward revealed a significant reduction in airborne fungus levels (P<.01), with average reductions of 75% for opportunistic species and 82% for nonpathogenic species. Our data indicate that the mobile, nonthermal-plasma air treatment unit tested in this study can rapidly reduce the levels of airborne particles and significantly lower the airborne bioburden in high-risk hospital environments.

  19. Analysis of hygienic critical control points in boar semen production.

    PubMed

    Schulze, M; Ammon, C; Rüdiger, K; Jung, M; Grobbel, M

    2015-02-01

    The present study addresses the microbiological results of a quality control audit in artificial insemination (AI) boar studs in Germany and Austria. The raw and processed semen of 344 boars in 24 AI boar studs were analyzed. Bacteria were found in 26% (88 of 344) of the extended ejaculates and 66.7% (18 of 24) of the boar studs. The bacterial species found in the AI dose were not cultured from the respective raw semen in 95.5% (84 of 88) of the positive samples. These data, together with the fact that in most cases all the samples from one stud were contaminated with identical bacteria (species and resistance profile), indicate contamination during processing. Microbiological investigations of the equipment and the laboratory environment during semen processing in 21 AI boar studs revealed nine hygienic critical control points (HCCP), which were addressed after the first audit. On the basis of the analysis of the contamination rates of the ejaculate samples, improvements in the hygiene status were already present in the second audit (P = 0.0343, F-test). Significant differences were observed for heating cabinets (improvement, P = 0.0388) and manual operating elements (improvement, P = 0.0002). The odds ratio of finding contaminated ejaculates in the first and second audit was 1.68 (with the 95% confidence interval ranging from 1.04 to 2.69). Furthermore, an overall good hygienic status was shown for extenders, the inner face of dilution tank lids, dyes, and ultrapure water treatment plants. Among the nine HCCP considered, the most heavily contaminated samples, as assessed by the median scores throughout all the studs, were found in the sinks and/or drains. High numbers (>10(3) colony-forming units/cm(2)) of bacteria were found in the heating cabinets, ejaculate transfer, manual operating elements, and laboratory surfaces. In conclusion, the present study emphasizes the need for both training of the laboratory staff in monitoring HCCP in routine semen production and audits in such AI centers for the external control of hygiene parameters. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Comparison of methods to control floor contamination in an animal research facility.

    PubMed

    Allen, Kenneth P; Csida, Tarrant; Leming, Jeaninne; Murray, Kathleen; Gauld, Stephen B; Thulin, Joseph

    2012-10-01

    The authors evaluated the effectiveness of adhesive mats, contamination control flooring, and shoe covers in decreasing the presence of microbial agents on animal holding room floors and footwear. Swab samples taken from animal holding room floors after the use of each product were compared with samples taken from rooms after no products were used. Swab samples were also taken from the heels and soles of the footwear of animal care staff before and after use of each product. The use of contamination control flooring or shoe covers significantly reduced the amount of organic material (as indicated by ATP levels measured by a luminometer) present on floors. Bacterial and ATP contamination of footwear was significantly lower after the use of shoe covers than after the use of adhesive mats or contamination control flooring, and the use of shoe covers led to a greater decrease in contamination before and after use than did use of either of the other two products. Although shoe covers were superior to both adhesive mats and contamination control flooring for decreasing contamination of animal room floors and footwear, facilities must take into account the contamination control standards required, the cost of the product, and the labor and time associated with product use when deciding which contamination control practices to implement.

  1. Response of soil microbial communities to red mud-based stabilizer remediation of cadmium-contaminated farmland.

    PubMed

    Li, Hui; Liu, Lemian; Luo, Lin; Liu, Yan; Wei, Jianhong; Zhang, Jiachao; Yang, Yuan; Chen, Anwei; Mao, Qiming; Zhou, Yaoyu

    2018-04-01

    In this work, a field test was conducted to investigate the effects of heavy metal stabilizer addition on brown rice and microbial variables in a cadmium (Cd)-contaminated farmland from April to October in 2016. Compared with the control, red mud-based stabilizer (RMDL) effectively reduced the concentration of Cd in brown rice (with the removal rate of 48.14% in early rice, 20.24 and 47.62% in late rice). The results showed that adding 0.3 kg m -2 RDML in early rice soil or soil for both early and late rice increased the microbial biomass carbon (MBC), the number of culturable heterotrophic bacteria and fungi, and the catalase activity in soil at different stages of paddy rice growth. Furthermore, there was no notable difference in the diversity of the bacterial species, community composition, and relative abundance at phylum (or class) or operational taxonomic unit (OTU) levels between the control and treatment (RMDL addition) groups. In a word, RMDL could be highly recommended as an effective remediation stabilizer for Cd-contaminated farmland, since its continuous application in paddy soil cultivating two seasons rice soil could effectively decrease the Cd content in brown rice and had no negative impact on soil microorganisms.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    JOHNSON, A.R.

    Biological control is any activity taken to prevent, limit, clean up, or remediate potential environmental, health and safety, or workplace quality impacts from plants, animals, or microorganisms. At Hanford the principal emphasis of biological control is to prevent the transport of radioactive contamination by biological vectors (plants, animals, or microorganisms), and where necessary, control and clean up resulting contamination. Other aspects of biological control at Hanford include industrial weed control (e.g.; tumbleweeds), noxious weed control (invasive, non-native plant species), and pest control (undesirable animals such as rodents and stinging insects; and microorganisms such as molds that adversely affect the qualitymore » of the workplace environment). Biological control activities may be either preventive (apriori) or in response to existing contamination spread (aposteriori). Surveillance activities, including ground, vegetation, flying insect, and other surveys, and apriori control actions, such as herbicide spraying and placing biological barriers, are important in preventing radioactive contamination spread. If surveillance discovers that biological vectors have spread radioactive contamination, aposteriori control measures, such as fixing contamination, followed by cleanup and removal of the contamination to an approved disposal location are typical response functions. In some cases remediation following the contamination cleanup and removal is necessary. Biological control activities for industrial weeds, noxious weeds and pests have similar modes of prevention and response.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    JOHNSON, A.R.

    Biological control is any activity taken to prevent, limit, clean up, or remediate potential environmental, health and safety, or workplace quality impacts from plants, animals, or microorganisms. At Hanford the principal emphasis of biological control is to prevent the transport of radioactive contamination by biological vectors (plants, animals, or microorganisms), and where necessary, control and clean up resulting contamination. Other aspects of biological control at Hanford include industrial weed control (e.g.; tumbleweeds), noxious weed control (invasive, non-native plant species), and pest control (undesirable animals such as rodents and stinging insects, and microorganisms such as molds that adversely affect the qualitymore » of the workplace environment). Biological control activities may be either preventive (a priori) or in response to existing contamination spread (a posteriori). Surveillance activities, including ground, vegetation, flying insect, and other surveys, and a priori control actions, such as herbicide spraying and placing biological barriers, are important in preventing radioactive contamination spread. If surveillance discovers that biological vectors have spread radioactive contamination, a posteriori control measures, such as fixing contamination, followed by cleanup and removal of the contamination to an approved disposal location are typical response functions. In some cases remediation following the contamination cleanup and removal is necessary. Biological control activities for industrial weeds, noxious weeds and pests have similar modes of prevention and response.« less

  4. Technology Description Sheets form the AMC 1990 Technology Expo Held in Aberdeen Proving Ground, Maryland on 1-4 October 1990

    DTIC Science & Technology

    1990-10-04

    emission signals) " Compactness (can be hand-held). The ISOPADS was demonstrated to troop units at the Army Training Command, Grafenwoehr , West...To be controlled, the microwave chips and modules must be interconnected with remotely located components and subsystems. Utilizing metallic cables...forward observer systcm being developed for use in situations too dangerous for soldiers. such as nuclear- contaminated areas or in support of a minefield

  5. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units

    PubMed Central

    2011-01-01

    Background The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. Methods The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Results Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Conclusions Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency. PMID:21219613

  6. Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units.

    PubMed

    Smith, Gordon Wg; Goldie, Frank; Long, Steven; Lappin, David F; Ramage, Gordon; Smith, Andrew J

    2011-01-10

    The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.

  7. Drinking-water arsenic exposure modulates gene expression in human lymphocytes from a U.S. population.

    PubMed

    Andrew, Angeline S; Jewell, David A; Mason, Rebecca A; Whitfield, Michael L; Moore, Jason H; Karagas, Margaret R

    2008-04-01

    Arsenic exposure impairs development and can lead to cancer, cardiovascular disease, and diabetes. The mechanism underlying these effects remains unknown. Primarily because of geologic sources of contamination, drinking-water arsenic levels are above the current recommended maximum contaminant level of 10 microg/L in the northeastern, western, and north central regions of the United States. We investigated the effects of arsenic exposure, defined by internal biomarkers at levels relevant to the United States and similarly exposed populations, on gene expression. We conducted separate Affymetrix microarray-based genomewide analyses of expression patterns. Peripheral blood lymphocyte samples from 21 controls interviewed (1999-2002) as part of a case-control study in New Hampshire were selected based on high- versus low-level arsenic exposure levels. The biologic functions of the transcripts that showed statistically significant abundance differences between high- and low-arsenic exposure groups included an overrepresentation of genes involved in defense response, immune function, cell growth, apoptosis, regulation of cell cycle, T-cell receptor signaling pathway, and diabetes. Notably, the high-arsenic exposure group exhibited higher levels of several killer cell immunoglobulin-like receptors that inhibit natural killer cell activity. These findings define biologic changes that occur with chronic arsenic exposure in humans and provide leads and potential targets for understanding and monitoring the pathogenesis of arsenic-induced diseases.

  8. Incidence and Causes of Aconitum Alkaloid Poisoning in Hong Kong from 1989 to 2010.

    PubMed

    Chan, Thomas Y K

    2015-08-01

    Aconite roots contain Aconitum alkaloids, which are highly toxic cardiotoxins and neurotoxins. In this review, the main objective was to determine the incidence and causes of Aconitum alkaloid poisoning in Hong Kong between 1989 and 2010, based on six published reports from the territory-wide poison control units. In the New Territories East of Hong Kong, the incidence of aconite poisoning showed a sudden and sustained decrease from 0.60 (1989-1991) to 0.16 (1992-1993) and 0.17 (1996-1998) per 100 000 population, after publicity measures in late 1991 to promote awareness of the toxicity of aconite roots. In the whole of Hong Kong, the incidence of aconite poisoning was even lower in January 2000-June 2004 (0.03 per 100 000 population). However, aconite poisoning became more common again in April 2004-July 2009 and 2008-2010 (0.15 and 0.28 per 100 000 population). Overdoses and use of inadequately processed aconite roots were important causes. As from 2004 to 2009, 'hidden' aconite poisoning (toxicity caused by contaminants in other dispensed herbs) emerged as an important cause. It is important to continue the safety monitoring of potent herbs and the networking of poison control units. Further systematic studies would be required to identify the likely sources of contamination of herbs. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Assessment of contamination and misclassification biases in a randomized controlled trial of a social network peer education intervention to reduce HIV risk behaviors among drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand.

    PubMed

    Simmons, Nicole; Donnell, Deborah; Ou, San-San; Celentano, David D; Aramrattana, Apinun; Davis-Vogel, Annet; Metzger, David; Latkin, Carl

    2015-10-01

    Controlled trials of HIV prevention and care interventions are susceptible to contamination. In a randomized controlled trial of a social network peer education intervention among people who inject drugs and their risk partners in Philadelphia, PA and Chiang Mai, Thailand, we tested a contamination measure based on recall of intervention terms. We assessed the recall of test, negative and positive control terms among intervention and control arm participants and compared the relative odds of recall of test versus negative control terms between study arms. The contamination measures showed good discriminant ability among participants in Chiang Mai. In Philadelphia there was no evidence of contamination and little evidence of diffusion. In Chiang Mai there was strong evidence of diffusion and contamination. Network structure and peer education in Chiang Mai likely led to contamination. Recall of intervention materials can be a useful method to detect contamination in experimental interventions.

  10. Ground-water flow in the shallow aquifer system at the Naval Weapons Station Yorktown, Virginia

    USGS Publications Warehouse

    Smith, Barry S.

    2001-01-01

    The Environmental Directorate of the Naval Weapons Station Yorktown, Virginia, is concerned about possible contamination of ground water at the Station. Ground water at the Station flows through a shallow system of layered aquifers and leaky confining units. The units of the shallow aquifer system are the Columbia aquifer, the Cornwallis Cave confining unit, the Cornwallis Cave aquifer, the Yorktown confining unit, and the Yorktown-Eastover aquifer. The Eastover-Calvert confining unit separates the shallow aquifer system from deeper confined aquifers beneath the Station. A three-dimensional, finite-difference, ground-water flow model was used to simulate steady-state ground-water flow of the shallow aquifer system in and around the Station. The model simulated ground-water flow from the peninsular drainage divide that runs across the Lackey Plain near the southern end of the Station north to King Creek and the York River and south to Skiffes Creek and the James River. The model was calibrated by minimizing the root mean square error between 4 7 measured and corresponding simulated water levels. The calibrated model was used to determine the ground-water budget and general directions of ground-water flow. A particle-tracking routine was used with the calibrated model to estimate groundwater flow paths, flow rates, and traveltimes from selected sites at the Station. Simulated ground-water flow velocities of the Station-area model were small beneath the interstream areas of the Lackey Plain and Croaker Flat, but increased outward toward the streams and rivers where the hydraulic gradients are larger. If contaminants from the land surface entered the water table at or near the interstream areas of the Station, where hydraulic gradients are smaller, they would migrate more slowly than if they entered closer to the streams or the shores of the rivers where gradients commonly are larger. The ground-water flow simulations indicate that some ground water leaks downward from the water table to the Yorktown confining unit and, where the confining unit is absent, to the Yorktown-Eastover aquifer. The velocities of advective-driven contaminants would decrease considerably when entering the Yorktown confining unit because the hydraulic conductivity of the confining unit is small compared to that of the aquifers. Any contaminants that moved with advective ground-water flow near the groundwater divide of the Lackey Plain would move relatively slowly because the hydraulic gradients are small there. The direction in which the contaminants would move, however, would be determined by precisely where the contaminants entered the water table. The model was not designed to accurately simulate ground-water flow paths through local karst features. Beneath Croaker Flat, ground water flows downward through the Columbia aquifer and the Yorktown confining unit into the Yorktown-Eastover aquifer. Analyses of the movement of simulated particles from two adjacent sites at Croaker Flat indicated that ground-water flow paths were similar at first but diverged and discharged to different tributaries of Indian Field Creek or to the York River. These simulations indicate that complex and possibly divergent flow paths and traveltimes are possible at the Station. Although the Station-area model is not detailed enough to simulate ground-water flow at the scales commonly used to track and remediate contaminants at specific sites, general concepts about possible contaminant migration at the Station can be inferred from the simulations.

  11. Extraction of contaminants from a gas

    DOEpatents

    Babko-Malyi, Sergei

    2000-01-01

    A method of treating industrial gases to remove contaminants is disclosed. Ions are generated in stream of injectable gas. These ions are propelled through the contaminated gas as it flows through a collection unit. An electric field is applied to the contaminated gas. The field causes the ions to move through the contaminated gases, producing electrical charges on the contaminants. The electrically charged contaminants are then collected at one side of the electric field. The injectable gas is selected to produce ions which will produce reactions with particular contaminants. The process is thus capable of removing particular contaminants. The process does not depend on diffusion as a transport mechanism and is therefore suitable for removing contaminants which exist in very low concentrations.

  12. Apparatus for extraction of contaminants from a gas

    DOEpatents

    Babko-Malyi, Sergei

    2001-01-01

    A method of treating industrial gases to remove contaminants is disclosed. Ions are generated in stream of injectable gas. These ions are propelled through the contaminated gas as it flows through a collection unit. An electric field is applied to the contaminated gas. The field causes the ions to move through the contaminated gases, producing electrical charges on the contaminants. The electrically charged contaminants are then collected at one side of the electric field. The injectable gas is selected to produce ions which will produce reactions with particular contaminants. The process is thus capable of removing particular contaminants. The process does not depend on diffusion as a transport mechanism and is therefore suitable for removing contaminants which exist in very low concentrations.

  13. Evaluation of a pulsed xenon ultraviolet light device for isolation room disinfection in a United Kingdom hospital.

    PubMed

    Hosein, Ian; Madeloso, Rosie; Nagaratnam, Wijayaratnam; Villamaria, Frank; Stock, Eileen; Jinadatha, Chetan

    2016-09-01

    Pathogen transmission from contaminated surfaces can cause hospital-associated infections. Although pulsed xenon ultraviolet (PX-UV) light devices have been shown to decrease hospital room bioburden in the United States, their effectiveness in United Kingdom (UK) hospitals is less understood. Forty isolation rooms at the Queens Hospital (700 beds) in North London, UK, were sampled for aerobic bacteria after patient discharge, after manual cleaning with a hypochlorous acid-troclosene sodium solution, and after PX-UV disinfection. PX-UV device efficacy on known organisms was tested by exposing inoculated agar plates in a nonpatient care area. Turnaround times for device usage were recorded, and a survey of hospital staff for perceptions of the device was undertaken. After PX-UV disinfection, the bacterial contamination measured in colony forming units (CFU) decreased by 78.4%, a 91% reduction from initial bioburden levels prior to terminal cleaning. PX-UV exposure resulted in a 5-log CFU reduction for multidrug-resistant organisms (MDROs) on spiked plates. The average device turnaround time was 1 hour, with minimal impact on patient throughput. Ward staff were enthusiastic about device deployment, and device operators reported physical comfort in usage. PX-UV use decreased bioburden in patient discharge rooms and on agar plates spiked with MDROs. The implementation of the PX-UV device was well received by hospital cleaning and ward staff, with minimal disruption to patient flow. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  14. Outbreak of Serratia marcescens in a neonatal intensive care unit: contaminated unmedicated liquid soap and risk factors.

    PubMed

    Buffet-Bataillon, S; Rabier, V; Bétrémieux, P; Beuchée, A; Bauer, M; Pladys, P; Le Gall, E; Cormier, M; Jolivet-Gougeon, A

    2009-05-01

    This study describes an outbreak of Serratia marcescens and its investigation and control in a neonatal intensive care unit (NICU). During a three-month period, five infants were colonised or infected by a single strain of S. marcescens. A case-control study, culture surveys and pulse-field gel electrophoresis analysis implicated a bottle soap dispenser as a reservoir of S. marcescens (P=0.032). Infants with S. marcescens colonisation or infection were also more likely to have been exposed to a central or percutaneous venous catheter (P=0.05) and had had longer exposure to endotracheal intubation (P=0.05). Soap dispensers are used in many hospitals and may be an unrecognised source of nosocomial infections. This potential source of infection could be reduced by using 'airless' dispensers which have no air intake for the distribution of soap. Prompt intervention and strict adherence to alcoholic hand disinfection were the key factors that led to the successful control of this outbreak.

  15. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed Central

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-01-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary. PMID:2379868

  16. Nosocomial outbreak of Legionella pneumophila serogroup 3 pneumonia in a new bone marrow transplant unit: evaluation, treatment and control.

    PubMed

    Oren, I; Zuckerman, T; Avivi, I; Finkelstein, R; Yigla, M; Rowe, J M

    2002-08-01

    A nosocomial outbreak of pneumonia caused by Legionella pneumophila serogroup 3 occurred in four patients following hematopoietic stem cell transplantation (HSCT) in a new bone marrow transplantation (BMT) unit during a 2 week period. The causative organism was recovered from the water supply system to the same unit just before the outbreak. Nineteen other BMT patients were hospitalized in the same unit at the same time, giving a frequency of proven infection of 4/23 = 17%. Immediately after recognition of the outbreak, use of tap water was forbidden, humidifiers were disconnected, and ciprofloxacin prophylaxis was started for all patients in the unit, until decontamination of the water was achieved. No other cases were detected. In conclusion, contamination of the hospital water supply system with legionella carries a high risk for legionella pneumonia among BMT patients. Early recognition of the outbreak, immediate restrictions of water use, antibiotic prophylaxis for all non-infected patients, and water decontamination, successfully terminated the outbreak.

  17. [Evaluation of human health risk for a population from Cali, Colombia, by exposure to lead, cadmium, mercury, 2,4-dichloro-phenoxyacetic acid and diuron associated with water and food consumption].

    PubMed

    Echeverry, Ghisliane; Zapata, Andrés Mauricio; Páez, Martha Isabel; Méndez, Fabián; Peña, Miguel

    2015-08-01

    Exposure to pollutants such as pesticides and heavy metals has been linked to health problems. Several studies have revealed the presence of these contaminants in Cali; however, there is no information available about the main routes of exposure and risk of these contaminants. To estimate the risk associated with the intake of cadmium, lead and mercury, and pesticides 2,4-D and diuron through the consumption of water and food in a population in Cali. Population and environmental data were obtained, and a risk assessment was performed using United States Environmental Protection Agency guidelines. The concentrations of the evaluated pollutants were below permissible levels as established by the Colombian Ministerio de Ambiente, Vivienda y Desarrollo Territorial (3 µg/L -1 of cadmium; 10 µg/L -1 of lead; 1 µg/L -1 of mercury; 1 µg/L -1 of 2,4 D; 1 µg/L -1 of diuron). Salema butterfish ( Peprilus snyderi ) samples contained levels of cadmium between 20 and 80 µg/kg -1 , which are below the permissible limit set by the World Health Organization (100 µg/kg -1 ). The results of the risk assessment indicated that the carcinogenic and non-carcinogenic attributable risk to population health from the intake of food contaminants was below the maximum level permitted by the United States Environmental Protection Agency. It is believed that the findings in previous studies on pollutants may have been due to specific contamination events; therefore, monitoring and early warning about water intake is recommended. Furthermore, the report of cadmium being found in fish consumed as food suggests the need for quality control by regulators.

  18. Quantitative Microbial Risk Assessment of Pharmaceutical Products.

    PubMed

    Eissa, Mostafa Essam

    2017-01-01

    Monitoring of microbiological quality in the pharmaceutical industry is an important criterion that is required to justify safe product release to the drug market. Good manufacturing practice and efficient control on bioburden level of product components are critical parameters that influence the microbiological cleanliness of medicinal products. However, because microbial dispersion through the samples follows Poisson distribution, the rate of detection of microbiologically defective samples lambda (λ) decreases when the number of defective units per batch decreases. When integrating a dose-response model of infection (P inf ) of a specific objectionable microbe with a contamination module, the overall probability of infection from a single batch of pharmaceutical product can be estimated. The combination of P inf with detectability chance of the test (P det ) will yield a value that could be used as a quantitative measure of the possibility of passing contaminated batch units of product with a certain load of a specific pathogen and infecting the final consumer without being detected in the firm. The simulation study can be used to assess the risk of contamination and infection from objectionable microorganisms for sterile and non-sterile products. LAY ABSTRACT: Microbial contamination of pharmaceutical products is a global problem that may lead to infection and possibly death. While reputable pharmaceutical companies strive to deliver microbiologically safe products, it would be helpful to apply an assessment system for the current risk associated with pharmaceutical batches delivered to the drug market. The current methodology may be helpful also in determining the degree of improvement or deterioration on the batch processing flow until reaching the final consumer. Moreover, the present system is flexible and can be applied to other industries such as food, cosmetics, or medical devices manufacturing and processing fields to assess the microbiological risk of the processed and manufactured batch. © PDA, Inc. 2017.

  19. Control of Listeria monocytogenes in goat's milk and goat's jben by the bacteriocinogenic Enterococcus faecium F58 strain.

    PubMed

    Achemchem, Fouad; Abrini, Jamal; Martínez-Bueno, Manuel; Valdivia, Eva; Maqueda, Mercedes

    2006-10-01

    The bacteriocinogenic Enterococcus faecium F58 strain, a natural goat's jben cheese isolate, lacks decarboxylase activity involved in most biogenic amine formation. It was also sensitive to 13 antibiotics assayed and free of virulence and vancomycin resistance genes. The F58 strain reached the stationary phase after 12 h of growth in sterile goat's milk, and the production of enterocin F-58 (Ent L50) was first detected after 48 h (400 AU/ml), thereafter remaining stable up to 5 days. The effectiveness of the F58 strain in controlling Listeria monocytogenes serovar 4b in reduced fat and whole goat's milk, and in goat's jben has been examined. Coculture experiments of F58-L. monocytogenes in both types of milk demonstrated that listeriae were not eliminated, although reductions by 1 to 4 log units were found. Nevertheless, when the F58 strain was previously inoculated in whole milk and left to grow for 12 h before contamination, the pathogen was completely eliminated after 130 h of coculture. Production of jben cheese contaminated with L. monocytogenes prior to packaging, using preparations of F58-producer strain, caused a significant decrease in the number of viable listeriae, which were undetectable after 1 week of cheese storage at 22 degrees C. Altogether, results from this study suggest that E. faecium F58 strain may be used as an adjunct culture in cheese to control contamination and growth of L. monocytogenes by in situ enterocin production, thus providing an additional hurdle to enhance control of this pathogen.

  20. DEMOLISHING A COLD WARE ERA FULE STORAGE BASIN SUPERSTRUCTURE LADEN WITH ASBESTOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LLOYD ER; STEVENS JM; DAGAN EB

    The K East (KE) Basin facilities are located near the north end of the Hanford Site's 100 K area. The facilities were built in 1950 as part of the KE Reactor complex and constructed within 400 meters of the Columbia River, which is the largest river in the Pacific Northwest and by volume the fourth largest river in the United States. The basin, located adjacent to the reactor, was used for the underwater storage of irradiated nuclear fuel discharged from the reactor. The basin was covered by a superstructure comprising steel columns and beams, concrete, and cement asbestos board (CAB)more » siding. The project's mission was to complete demolition of the structure over the KE Basin within six months of turnover from facility deactivation activities. The demolition project team applied open-air demolition techniques to bring the facility to slab-on-grade. Several innovative techniques were used to control contamination and maintain contamination control within the confines of the demolition exclusion zone. The techniques, which focused on a defense-in-depth approach, included spraying fixatives on interior and exterior surfaces before demolition began; applying fixatives during the demolition; misting using a fine spray of water during demolition; and demolishing the facility systematically. Another innovative approach that made demolition easier was to demolish the building with the non-friable CAB remaining in place. The CAB siding covered the exterior of the building and portions of the interior walls, and was an integral part of the multiple-layered roof. The project evaluated the risks involved in removing the CAB material in a radiologically contaminated environment and determined that radiological dose rates and exposure to radiological contamination and industrial hazards would be significantly reduced by using heavy equipment to remove the CAB during demolition. The ability to perform this demolition safely and without spreading contamination (radiological or asbestos) demonstrates that contaminated structures can be torn down successfully using similar open-air demolition techniques.« less

  1. Evaluation of Nonpoint-Source Contamination, Wisconsin: Selected Topics for Water Year 1995

    USGS Publications Warehouse

    Owens, D.W.; Corsi, Steven R.; Rappold, K.F.

    1997-01-01

    The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMP's) for controlling nonpoint-source contamination in eight rural and four urban watersheds. This report, the fourth in an annual series of reports, presents a summary of the data collected for the program by the U.S. Geological Survey and the results of several detailed analyses of the data. To complement assessments of water quality, a land-use and BMP inventory is ongoing for 12 evaluation monitoring projects to track nonpoint sources of contamination in each watershed and to document implementation of BMP's that were designed to cause changes in the water quality of streams. Each year, updated information is gathered, mapped, and stored in a geographic-information-system data base. Summaries of land-use, BMP implementation, and water-quality data collected during water years 1989-95 are presented. Storm loads, snowmelt-period loads, and annual loads of suspended sediment and total phosphorus are summarized for eight rural sites. Storm-load data for suspended solids, total phosphorus, total recoverable lead, copper, zinc, and cadmium are summarized for four urban sites. Quality-assurance and quality-control (QA/QC) samples were collected at the eight rural sites to evaluate inorganic sample contamination and at one urban site to evaluate sample-collection and filtration techniques for polycyclic aromatic hydrocarbons (PAR's). Some suspended solids and fecal coliform contamination was detected at the rural sites. Corrective actions will be taken to address this contamination. Evaluation of PAR sample-collection techniques did not uncover any deficiencies, but the small amount of data collected was not sufficient to draw any definite conclusions. Evaluation of PAR filtration techniques indicate that water-sample filtration with O.7-um glass-fiber filters in an aluminum filter unit does not result in significant loss of PAR.

  2. Human Health Screening and Public Health Significance of Contaminants of Emerging Concern Detected in Public Water Supplies

    EPA Science Inventory

    The source water and treated drinking water from twenty five drinking water treatment plants (DWTPs) across the United States were sampled in 2010 – 2012. Samples were analyzed for 247 contaminants using 15 chemical and microbiological methods. Most of these contaminants are no...

  3. Evaluation of targeted and untargeted effects-based monitoring tools to assess impacts of contaminants of emerging concern on fish in the South Platte River, CO

    EPA Science Inventory

    Rivers in the arid Western United States face increasing influences from anthropogenic contaminants due to population growth, urbanization, and drought. To better understand and more effectively track the impacts of these contaminants, biologically-based monitoring tools are incr...

  4. Strain diversity in the fecal indicator Escherichia coli: implications for its use as a produce pathogen surrogate

    USDA-ARS?s Scientific Manuscript database

    Contamination of food and water by pathogens is a substantial public health issue in the United States. One of the challenges in protecting the public against water and foodborne illness is understanding the routes of contamination. One suspected route of food contamination is irrigation water. Surf...

  5. Assessing the Educational Needs of Urban Gardeners and Farmers on the Subject of Soil Contamination

    ERIC Educational Resources Information Center

    Harms, Ashley Marie Raes; Presley, DeAnn Ricks; Hettiarachchi, Ganga M.; Thien, Stephen J.

    2013-01-01

    Participation in urban agriculture is growing throughout the United States; however, potential soil contaminants in urban environments present challenges. Individuals in direct contact with urban soil should be aware of urban soil quality and soil contamination issues to minimize environmental and human health risks. The study reported here…

  6. Nationwide reconnaissance of contaminants of emerging concern in source and treated drinking waters of the United States

    EPA Science Inventory

    When chemical or microbial contaminants are assessed for potential effect or possible regulation in ambient and drinking waters, a critical first step is determining if the contaminants occur and if they are at concentrations that may cause human or ecological health concerns. To...

  7. 32 CFR 536.35 - Unique issues related to environmental claims.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the United States based on contamination by toxic substances found in the air or the ground must be... geographical jurisdiction over the claim and USARCS. Claims for personal injury from contamination frequently arise at an area that is the subject of claims for cleanup of the contamination site. The cleanup claims...

  8. ADVANCED OXIDATION PROCESSES IN THE TREATMENT OF CONTAMINANT CANDIDATE LIST (CCL) COMPOUNDS

    EPA Science Inventory

    The current (2nd) Contaminant Candidate List was completed in 2005 by the United States EPA as an update to the Safe Drinking Water Act. The list of 42 chemical contaminants spans a wide array of classes, from pesticides to pharmaceuticals to elements, all of which are anticipate...

  9. WESTERN AIRBORNE CONTAMINANTS ASSESSMENT PROJECT (WACAP): ASSESSING DEPOSITION AND IMPACTS OF PERSISTENT ORGANIC POLLUTANTS AND METALS IN SEVEN NATIONAL PARKS IN THE WESTERN UNITED STATES

    EPA Science Inventory

    Airborne contaminants, especially those that biomagnify in the food chain, can pose serious health threats to wildlife and humans. Biological effects of airborne contaminants include impacts on reproductive success, growth, behavior, disease, and survival. In response to concer...

  10. Proceedings of the Tripartite Conference on Submarine Medicine (3rd)-- France, United Kingdom, and United States, 9-10 May 1983

    DTIC Science & Technology

    1983-06-01

    French Submarine Atmosphere Contaminants" .......... . J. P. Malaspina 181 Discussion ...... ......................... .. 193 Closing Remarks...industrial TLVs , which corresponds to what has just been mentioned, or because the listed contaminants are generally not present on board French submarines...Nevertheless, you do have a large scientific organization throughout your country to investigate some of these problems and probably more research

  11. Electrodialysis-based separation process for salt recovery and recycling from waste water

    DOEpatents

    Tsai, S.P.

    1997-07-08

    A method for recovering salt from a process stream containing organic contaminants is provided, comprising directing the waste stream to a desalting electrodialysis unit so as to create a concentrated and purified salt permeate and an organic contaminants-containing stream, and contacting said concentrated salt permeate to a water-splitting electrodialysis unit so as to convert the salt to its corresponding base and acid. 6 figs.

  12. Electrodialysis-based separation process for salt recovery and recycling from waste water

    DOEpatents

    Tsai, Shih-Perng

    1997-01-01

    A method for recovering salt from a process stream containing organic contaminants is provided, comprising directing the waste stream to a desalting electrodialysis unit so as to create a concentrated and purified salt permeate and an organic contaminants containing stream, and contacting said concentrated salt permeate to a water-splitting electrodialysis unit so as to convert the salt to its corresponding base and acid.

  13. Superfund record of decision amendment (EPA Region 5): Woodstock Municipal LF, Woodstock, IL, July 15, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This decision document represents the United States Environmental Protection Agency`s (US EPA) selected final remedial action for the Site located in Woodstock, Illinois. The US EPA, in consultation with the IEPA, is modifying the landfill cap profile, and the requirement to construct a groundwater pump-and-treat system to address residual vinyl chloride contamination in the upper water-bearing unit, down gradient of the landfill. This remedy is intended to be the final action for the site, and addresses all contaminated media, including: contaminated soil, sediment, and groundwater, landfilled wastes, leachate generation and emission of landfill gases.

  14. JPL Contamination Control Engineering

    NASA Technical Reports Server (NTRS)

    Blakkolb, Brian

    2013-01-01

    JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

  15. Superfund record of decision (EPA Region 4): T H Agriculture and Nutrition Site, Dougherty County, Albany, GA, April 26, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This decision document (Record of Decision), presents the selected Remedial Action for the Operable Unit Two for the T H Agriculture & Nutrition (THAN) Site, Albany, Georgia. The second operable unit addresses the source of the contamination on the eastern parcel of the Site. The major components of the selected remedy for operable unit two include: the excavation of all soil contaminated with organics necessary to meet performance standards; the staging and preconditioning of soil for low temperature thermal desorption treatment; the treatment of excavated soil by low temperature thermal desorption; the placement of treated, decontaminated soil back to themore » site; periodic sampling of treated soil during the treatment process to verify the effectiveness of the remedy; air monitoring to ensure safety of nearby residents and workers; groundwater monitoring to ensure that metals contaminated remaining in the subsurface soil will not result in contaminated groundwater migrating offsite in concentrations which exceed groundwater protection standards; and deed restrictions to prevent residential use of the property.« less

  16. [Bacterial contamination of the indoor air in a transplant unit].

    PubMed

    Matoušková, Ivanka; Holý, Ondřej

    2013-12-01

    For one year (August 2010 to July 2011), microbial contamination of the indoor air in the Transplant Unit of the Haemato-Oncology Clinic, Olomouc University Hospital was monitored monthly. Twenty sampling sites were singled out and a total of 240 indoor air samples were collected. An MAS-100 air sampler (Merck, GER) was used, air flow rate of 100 liters per minute, 1 minute. The measured values of indoor air temperature were stable. The relative air humidity ranged from 17% to 68%. The highest average value of microbial air contamination was found in the "staff entry room" (1170 CFU/m3). The lowest microbial air contamination (150-250 CFU/m3) was measured in the patient isolation units. The most frequently isolated bacterial strains were coagulase-negative staphylococci (94.3%), followed by Micrococcus spp. (67%) and Bacillus subtilis (11%). It can be assumed that the -source of these airborne bacterial strains are both patients and medical staff. They are classified as -opportunistic pathogens and as such can cause hospital infections among haemato-oncology patients.

  17. Effect of nebulized eucalyptus on contamination of microbial plaque of endotracheal tube in ventilated patients

    PubMed Central

    Amini, Nazanin; Rezaei, Korosh; Yazdannik, Ahmadreza

    2016-01-01

    Background: Formation of biofilm and bacterial colonization within the endotracheal tube (ETT) are significant sources of airway contamination and play a role in the development of ventilator-associated pneumonia (VAP). This study was conducted to examine the effect of nebulized eucalyptus (NE) on bacterial colonization of ETT biofilm. Materials and Methods: We performed a randomized clinical trial in three intensive care units (ICUs) of an educational hospital. Seventy intubated patients were selected and randomly divided into intervention (n = 35) and control (n = 35) groups. The intervention group received 4 ml (5%) of eucalyptus in 6 ml normal saline every 8 h. The placebo group received only 10 ml of normal saline in the same way. On extubation, the interior of the tube was immediately sampled using a sterile swab for standard microbiological analysis. Chi-square and Fisher's exact tests were used for statistical analysis in SPSS. P values less than 0.05 were considered statistically significant. Results: In both samples, Klebsiella pneumoniae and Acinetobacter baumannii were the most frequently isolated bacteria. In the control group, heavy colonization was greater than in the intervention group (P = 0.002). The frequency of isolation of K. pneumoniae in the intervention group was lower than in the control group (P < 0.001). However, there was no difference between the two groups in other isolated bacteria. Conclusions: NE can reduce microbial contamination of the endotracheal tube biofilm in ventilated patients. Moreover, K. pneumoniae was the most sensitive to NE. PMID:27095990

  18. The chemical quality of self-supplied domestic well water in the United States

    USGS Publications Warehouse

    Focazio, M.J.; Tipton, D.; Dunkle, Shapiro S.; Geiger, L.H.

    2006-01-01

    Existing water quality data collected from domestic wells were summarized to develop the first national-scale retrospective of self-supplied drinking water sources. The contaminants evaluated represent a range of inorganic and organic compounds, and although the data set was not originally designed to be a statistical representation of national occurrence, it encompasses large parts of the United States including at least some wells sampled in every state and Puerto Rico. Inorganic contaminants were detected in many of the wells, and concentrations exceeded the U.S. EPA maximum contaminant levels (MCLs; federal drinking water standards used to regulate public drinking water quality) more often than organic contaminants. Of the inorganic constituents evaluated, arsenic concentrations exceeded the MCL (10 ??g/L) in ???11% of the 7580 wells evaluated, nitrate exceeded the MCL (10 mg/L) in ???8% of the 3465 wells evaluated, uranium-238 exceeded the MCL (30 ??g/L) in ???4% of the wells, and radon-222 exceeded 300 and 4000 pCi/L (potential drinking water standards currently under review by the U.S. EPA) in ???75% and 9% of the wells, respectively. The MCLs for total mercury and fluoride were each exceeded in <1% of the wells evaluated. The MCL was exceeded in <1% of all wells for all anthropogenically derived organic contaminants evaluated and was not exceeded for many contaminants. In addition, 10 contaminants evaluated do not currently have an MCL. Atrazine, however, was detected in 24% of the wells evaluated and was the most frequently detected organic contaminant of the 28 organic contaminants evaluated in this study. Simazine and metolachlor each were detected in ???9% of all wells and tied for second in frequency of detection for organic contaminants. The third and fourth most frequently detected organic contaminants were methyl tert-butyl ether (MTBE) (6%) and chloroform (5%), respectively. Because the water quality of domestic wells is not federally regulated or nationally monitored, this study provides a unique, previously nonexistent, perspective on the quality of the self-supplied drinking water resources used by ???45 million Americans in the United States. Copyright ?? 2006 The Author(s).

  19. Decontaminating the DOE-STD-3013 Inner Container to Meet 10-CFR-835 Appendix D Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, H.E.; Nelson, T.O.; Rivera, Y.M.

    The United States Department of Energy (DOE) has published a standard that specifies the criteria for preparation and packaging of plutonium metals and oxides for safe long-term storage (DOE-STD-3013-96). This standard is followed for the packaging of materials resulting from the disassembly of nuclear weapons at Los Alamos National Laboratory under the Advanced Retirement and Integrated Extraction System (ARIES) project. Declassified plutonium metal or oxide material from the ARES project is packaged into doubly contained and welded type 304L stainless steel containers that comply with the DOE standard. The 3013-96 standard describes requirements for maximum contamination limits on the outermore » surface of the sealed inner container. These limits are 500 dpm per 100 cm2 for direct measurements and 20 dpm per 100 cm2 for removable contamination. For containers filled, welded, and handled inside a highly contaminated glovebox line, these limits are difficult to obtain. Simple handling within the line is demonstrated to contaminate surfaces from 10,000 to 10,000,000 dpm alpha per 100 cm2. To routinely achieve contamination levels below the maximum contamination levels specified by the 3013-96 standard within a processing operation, a decontamination step must be included. In the ARIES line, this decontamination step is an electrolytic process that produces a controlled uniform etch of the container surfaces. Decontamination of the 3013-96 compliant ARIES inner container is well demonstrated. Within 30 to 50 minutes electrolysis time, tixed contamination is reduced to hundreds of dpm generally occurring only at electrode contact points and welds. Removable contamination is routinely brought to non-detectable levels. The total process time for the cycle (includes electrolysis, rinse, and dry stages) is on the order of 1.5 to 2 hours per container. The ARIES inner container decontamination system highly automated and consists of a plumbing loop, electronic controls and process monitors, and a decontamination chamber or "fixture". The tixture is situated like an air lock between a contaminated and an uncontaminated section of a processing glovebox. The welded and leak tested container is placed into the fixture through a door on the contaminated side and the electrolysis process is run, including rinse and dry cycles. The container is then removed through a second door into the uncontaminated side where it is monitored for surface alpha contamination, leak checked, and reweighed.« less

  20. Contamination control research activities for space optics in JAXA RANDD

    NASA Astrophysics Data System (ADS)

    Kimoto, Y.

    2017-11-01

    Contamination control research activities for space optics projects in JAXA R&D are described. More accurate contamination control techniques are requested because of intensified recent science mission requirements. One approach to control the contamination effects is analysis by software. JAXA has been developing a contamination analytical tool "J-SPICE" (Japanese Spacecraft Induced Contamination analysis software) as well as experiment facilities to improve the J-SPICE. A reflection model in J-SPICE has been experimentally verified and outgassing model data has been acquired by a facility. JAXA has developed a facility which could determine the influence of the contamination at a specific wavelength by combining a vacuum chamber with an I-R spectrometer and performed an experiment to inspect the effect of baking. Space material exposure experiment results reveal the actual thickness of the contamination layer in ISS orbit.

  1. Modelling the effects of contaminated environments on HFMD infections in mainland China.

    PubMed

    Wang, Jinyan; Xiao, Yanni; Cheke, Robert A

    2016-02-01

    Hand-foot-mouth disease (HFMD) has spread widely in mainland China increasing in prevalence in most years with serious consequences for child health. The HFMD virus can survive for a long period outside the host in suitable conditions, and hence contaminated environments may play important roles in HFMD infection. A new mathematical model was proposed and used to investigate the roles that asymptomatic individuals and contaminated environments played in HFMD dynamics. The model includes both direct transmission between susceptible and infected individuals and indirect transmission via free-living infectious unites in the environment. Theoretical analysis shows that the disease goes to extinction if the basic reproduction number is less than unity, whilst otherwise the disease persists. By fitting the proposed model to surveillance data we estimated the basic reproduction number as 1.509. Numerical simulations show that increasing the rate of virus clearance and decreasing transmission rates can delay epidemic outbreaks and weaken the severity of HFMD. Sensitivity analysis indicated that the basic reproduction number is sensitive to the transmission rate induced by asymptomatic infectious individuals and parameters associated with contaminated environments such as the indirect transmission rate, the rate of clearance and the virus shedding rates. This implies that asymptomatic infectious individuals and contaminated environments contribute substantially to new HFMD infections, and so would be targets for effective control measures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Contaminated land in Colombia: A critical review of current status and future approach for the management of contaminated sites.

    PubMed

    Arias Espana, Victor Andres; Rodriguez Pinilla, Alfonso R; Bardos, Paul; Naidu, Ravi

    2018-03-15

    Environmental contaminants can have negative effects on human health and land, air and water resources. Consequently, there have been significant advances in regulation for protecting the environment in developed countries including the development of remediation frameworks and guidelines. On the other hand, fewer studies have been reported on the risks and health effects of contaminants in developing regions and there is scarce information regarding contaminated land assessment and environmental remediation. Colombia is an important emerging economy and has started to take the first steps towards the development of a framework for the management of contaminated sites and there are opportunities for the country to learn from countries with well-established frameworks such as the United States (US) and the United Kingdom (UK) and for international collaboration with organisations such as CRC for Contamination Assessment and Remediation of the Environment (CARE). We review main pollution issues, current status of contaminated land management in Colombia to identify the gaps in policy and regulation. We also review the UK and US contaminated land policies and regulations to identify the elements of those experiences that could support progress in the country. Finally, we propose recommendations (e.g. risk based approach, soil screening criteria, clean-up funding, liability) for Colombia that could support further development and implementation of a more effective contaminated land management framework. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Controlling systematic perioperative anaerobic contamination during sinus-lift procedures by using metronidazole: an innovative approach.

    PubMed

    Choukroun, Joseph; Simonpieri, Alain; Del Corso, Marco; Mazor, Ziv; Sammartino, Gilberto; Dohan Ehrenfest, David M

    2008-09-01

    Analysis of tomodensitometric controls following sinus grafts clearly demonstrates a quite systematic lack of homogeneity. Sinus contamination by anaerobic bacteria seems almost unavoidable during bone graft surgery, and this problem may jeopardize the healing process. The aim of this study was to characterize in a systematic way the nonhomogeneities observed at 1, 2, or 3 months postsurgery within allogenous sinus grafts, and to assess the possible influence of a 0.5% sterile solution of metronidazole incorporated in the sinus bone graft. This clinical study was conducted on 72 patients treated with single or bilateral sinus-lifts: 94 sinus elevations performed with freeze-dried bone allograft (Phoenix, TBF, Mions, France), with (test group) or without (control group) metronidazole. In the test group, each bone graft was hydrated with 2 mL of a 0.5% metronidazole solution, i.e., only 10 mg of metronidazole. All the patients went through a first presurgical computerized tomography (CT)-scan followed by a second scan performed at 1, 2, or 3 months postsurgery (which was used as the preimplant reference scan). For 11 patients, 2 postsurgical CT-scans were performed respectively at 10 days and 2 months. Using an arbitrary gray scale (Arbitrary Densitometric Unit) which functions according to the Hounsfield unit principle, the degree of radiographic homogeneity of the grafts was established. Density scattering provides some information on the homogeneity or nonhomogeneity of the bone graft. The 12 grafts performed without metronidazole show significant nonhomogeneities at 1, 2, or 3 months. Moreover, when a CT-scan is performed during the first postoperative days (at 10 days), the presence of air bubbles in the graft is confirmed. The tomodensitometric aspects of all grafts treated with metronidazole in this series are absolutely identical: they show a high degree of homogeneity. Sixty-three cases (76.8%) are homogeneous, and 19 cases (23.2%) are significantly homogeneous. The time at which the control scan is performed (10 days, 1, 2, or 3 months) does not seem to influence significantly the degree of homogeneity assessed. In the control group, some inflammatory events associated with facial oedema were observed in 25% of the cases. In the test group, no such event was recorded for the 82 sinus-lifts treated with metronidazole. A possible correlation may exist between the occurrence of non homogeneities within the bone grafts and the anaerobic bacterial contamination. The local use of a very small quantity of metronidazole (equivalent to only 1/20 of a common 200 mg oral tablet) could provide more security when performing sinus-lift procedures and an improved quality of the graft. This protocol should not be considered as an antibiotherapy, but only as way to limit the initial contamination of bone graft.

  4. Assessment of contamination and misclassification biases in a randomized controlled trial of a social network peer education intervention to reduce HIV risk behaviors among drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand

    PubMed Central

    Simmons, Nicole; Donnell, Deborah; Ou, San-san; Celentano, David D.; Aramrattana, Apinun; Davis-Vogel, Annet; Metzger, David; Latkin, Carl

    2015-01-01

    Context Controlled trials of educational interventions are susceptible to contamination. Objectives To test a contamination measure based on recall of terms. Main study A randomized controlled trial of a social network peer education intervention among 1,123 injection drug users and risk partners in Philadelphia, PA and Chiang Mai, Thailand. Methods We assessed the recall of test, negative and positive control terms by intervention and control arm participants and compared the relative odds (OR) of recall of test vs. negative control terms between study arms. Results The contamination measure showed good discriminant ability only among participants from Chiang Mai. In Philadelphia there was no evidence of contamination and little evidence of diffusion. In Chiang Mai there was evidence of diffusion and contamination of 4 of 5 terms tested. Conclusions Network structure and peer education in Chiang Mai likely led to contamination. Recall of intervention materials can be a useful method to detect contamination in trials of educational interventions. PMID:25935214

  5. Pre-post evaluation of effects of a titanium dioxide coating on environmental contamination of an intensive care unit: the TITANIC study.

    PubMed

    de Jong, B; Meeder, A M; Koekkoek, K W A C; Schouten, M A; Westers, P; van Zanten, A R H

    2018-07-01

    Among patients admitted to European hospitals or intensive care units (ICUs), 5.7% and 19.5% will encounter healthcare-associated infections (HAIs), respectively, and antimicrobial resistance is emerging. As hospital surfaces are contaminated with potentially pathogenic bacteria, environmental cleanliness is an essential aspect to reduce HAIs. To address the efficacy of a titanium dioxide coating in reducing the microbial colonization of environmental surfaces in an ICU. A prospective, controlled, single-centre pilot study was conducted to examine the effect of a titanium dioxide coating on the microbial colonization of surfaces in an ICU. During the pre- and post-intervention periods, surfaces were cultured with agar contact plates (BBL RODAC plates). Factors that were potentially influencing the bacterial colonization of surfaces were recorded. A repeated measurements analysis within a hierarchic multi-level framework was used to analyse the effect of the intervention, controlling for the explanatory variables. The mean ratio for the total number of colony-forming units (cfus) in a room between the pre- and post-intervention periods was 0.86 (standard deviation 0.57). The optimal model included the following explanatory variables: intervention (P=0.065), week (P=0.002), culture surfaces (P<0.001), ICU room (P=0.039), and interaction between intervention and week (P=0.002) and between week and culture surfaces (P=0.031). The effect of the intervention on the number of cfus from all culture plates in Week 4 between the pre- and post-intervention periods was -0.47 (95% confidence interval -0.24 to - 0.70). This study found that a titanium dioxide coating had no effect on the microbial colonization of surfaces in an ICU. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  6. Contamination Control in Hybrid Microelectronic Modules. Part 1: Identification of Critical Process and Contaminants

    NASA Technical Reports Server (NTRS)

    Himmel, R. P.

    1975-01-01

    Various hybrid processing steps, handling procedures, and materials are examined in an attempt to identify sources of contamination and to propose methods for the control of these contaminants. It is found that package sealing, assembly, and rework are especially susceptible to contamination. Moisture and loose particles are identified as the worst contaminants. The points at which contaminants are most likely to enter the hybrid package are also identified, and both general and specific methods for their detection and control are developed. In general, the most effective controls for contaminants are: clean working areas, visual inspection at each step of the process, and effective cleaning at critical process steps. Specific methods suggested include the detection of loose particles by a precap visual inspection, by preseal and post-seal electrical testing, and by a particle impact noise test. Moisture is best controlled by sealing all packages in a clean, dry, inert atmosphere after a thorough bake-out of all parts.

  7. 40 CFR 279.53 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration... contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units. [57 FR...

  8. 40 CFR 279.53 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration... contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units. [57 FR...

  9. 40 CFR 279.53 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration... contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units. [57 FR...

  10. 40 CFR 279.53 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration... contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units. [57 FR...

  11. 40 CFR 279.53 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration... contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units. [57 FR...

  12. Results from the NOAA National Status and Trends Program on distribution and effects of chemical contamination in the coastal and estuarine United States.

    PubMed

    O'Connor, T P; Ehler, C N

    1991-04-01

    The NOAA National Status and Trends (NS&T) Program has been monitoring chemical contamination in fish livers, and surface sediments since 1984 and in molluscan tissue and sediments since 1986. Data from fine-grained sediment at 175 sites are used to describe the spatial distribution of contamination throughout the coastal and estuarine United States. Highest levels are generally found in, and considered representative of, urban areas. It should be noted, however, that these levels are not as high as have been found near discharge pipes or in isolated industrial areas through other monitoring efforts. Dramatic biological responses, such as liver tumors in fish or apparently toxic contaminant levels in sediment, are found infrequently. Subtle biological changes, especially those that affect reproductive ability, are being sought. Data from three annual collections of mollusks have been used to identify early signals of temporal trends in contamination at NS&T sites.

  13. Prevalence, level and distribution of Salmonella in shipments of imported capsicum and sesame seed spice offered for entry to the United States: observations and modeling results.

    PubMed

    Van Doren, Jane M; Blodgett, Robert J; Pouillot, Régis; Westerman, Ann; Kleinmeier, Daria; Ziobro, George C; Ma, Yinqing; Hammack, Thomas S; Gill, Vikas; Muckenfuss, Martin F; Fabbri, Linda

    2013-12-01

    In response to increased concerns about spice safety, the United States Food and Drug Administration (FDA) initiated research to characterize the prevalence and levels of Salmonella in imported spices. 299 imported dried capsicum shipments and 233 imported sesame seed shipments offered for entry to the United States were sampled. Observed Salmonella shipment prevalence was 3.3% (1500 g examined; 95% CI 1.6-6.1%) for capsicum and 9.9% (1500 g; 95% Confidence Interval (CI) 6.3-14%) for sesame seed. Within shipment contamination was not inconsistent with a Poisson distribution. Shipment mean Salmonella level estimates among contaminated shipments ranged from 6 × 10(-4) to 0.09 (capsicum) or 6 × 10(-4) to 0.04 (sesame seed) MPN/g. A gamma-Poisson model provided the best fit to observed data for both imported shipments of capsicum and imported shipments of sesame seed sampled in this study among the six parametric models considered. Shipment mean levels of Salmonella vary widely between shipments; many contaminated shipments contain low levels of contamination. Examination of sampling plan efficacy for identifying contaminated spice shipments from these distributions indicates that sample size of spice examined is critical. Sampling protocols examining 25 g samples are predicted to be able to identify a small fraction of contaminated shipments of imported capsicum or sesame seeds. Published by Elsevier Ltd.

  14. Contamination control in hybrid microelectronic modules. Identification of critical process and contaminants, part 1

    NASA Technical Reports Server (NTRS)

    Himmel, R. P.

    1975-01-01

    Hybrid processes, handling procedures, and materials were examined to identify the critical process steps in which contamination is most likely to occur, to identify the particular contaminants associated with these critical steps, and to propose method for the control of these contaminants.

  15. Relating to monitoring ion sources

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan

    2002-01-01

    The apparatus and method provide techniques for monitoring the position on alpha contamination in or on items or locations. The technique is particularly applicable to pipes, conduits and other locations to which access is difficult. The technique uses indirect monitoring of alpha emissions by detecting ions generated by the alpha emissions. The medium containing the ions is moved in a controlled manner frog in proximity with the item or location to the detecting unit and the signals achieved over time are used to generate alpha source position information.

  16. Functional Agents to Biologically Control Deoxynivalenol Contamination in Cereal Grains

    PubMed Central

    Tian, Ye; Tan, Yanglan; Liu, Na; Liao, Yucai; Sun, Changpo; Wang, Shuangxia; Wu, Aibo

    2016-01-01

    Mycotoxins, as microbial secondary metabolites, frequently contaminate cereal grains and pose a serious threat to human and animal health around the globe. Deoxynivalenol (DON), a commonly detected Fusarium mycotoxin, has drawn utmost attention due to high exposure levels and contamination frequency in the food chain. Biological control is emerging as a promising technology for the management of DON contamination. Functional biological control agents (BCAs), which include antagonistic microbes, natural fungicides derived from plants and detoxification enzymes, can be used to control DON contamination at different stages of grain production. In this review, studies regarding different biological agents for DON control in recent years are summarized for the first time. Furthermore, this article highlights the significance of BCAs for controlling DON contamination, as well as the need for more practical and efficient BCAs concerning food safety. PMID:27064760

  17. International Space Station External Contamination Status

    NASA Technical Reports Server (NTRS)

    Mikatarian, Ron; Soares, Carlos

    2000-01-01

    PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.

  18. Outbreak of drug-resistant Acinetobacter baumannii ST219 caused by oral care using tap water from contaminated hand hygiene sinks as a reservoir.

    PubMed

    Umezawa, Kazuo; Asai, Satomi; Ohshima, Toshio; Iwashita, Hideo; Ohashi, Maya; Sasaki, Mika; Kaneko, Akihiro; Inokuchi, Sadaki; Miyachi, Hayato

    2015-11-01

    An outbreak of amikacin- and ciprofloxacin-resistant Acinetobacter baumannii ST219 in Tokai University hospital's emergency intensive care unit was caused by its colonization in water systems and subsequent spread through oral care using tap water. The outbreak was successfully controlled after replacement of the water system and implementation as of daily cleaning of water taps and oral care with a dry method. It is important to strictly manage the water system in critical care areas. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szescody, James E.; Moore, Robert C.; Rigali, Mark J.

    The Old Rifle Site is a former vanadium and uranium ore-processing facility located adjacent to the Colorado River and approximately 0.3 miles east of the city of Rifle, CO. The former processing facilities have been removed and the site uranium mill tailings are interned at a disposal cell north of the city of Rifle. However, some low level remnant uranium contamination still exists at the Old Rifle site. In 2002, the United States Nuclear Regulatory Commission (US NRC) concurred with United States Department of Energy (US DOE) on a groundwater compliance strategy of natural flushing with institutional controls to decreasemore » contaminant concentrations in the aquifer. In addition to active monitoring of contaminant concentrations, the site is also used for DOE Legacy Management (LM) and other DOE-funded small-scale field tests of remediation technologies. The purpose of this laboratory scale study was to evaluate the effectiveness of a hydroxyapatite (Ca 10(PO 4) 6(OH) 2) permeable reactive barrier and source area treatment in Old Rifle sediments. Phosphate treatment impact was evaluated by comparing uranium leaching and surface phase changes in untreated to PO 4-treated sediments. The impact of the amount of phosphate precipitation in the sediment on uranium mobility was evaluated with three different phosphate loadings. A range of flow velocity and uranium concentration conditions (i.e., uranium flux through the phosphate-treated sediment) was also evaluated to quantify the uranium uptake mass and rate by the phosphate precipitate.« less

  20. Attempts to control clothes-borne infection in a burn unit, 2. Clothing routines in clinical use and the epidemiology of cross-colonization.

    PubMed Central

    Ransjö, U.

    1979-01-01

    Previous investigations have shown that cross-contamination in a burn unit is mainly clothes-borne. New barrier garments have been designed and tried experimentally. The aim of the present study was to investigate the effects of different clothing routines on cross-contamination. In a long-term study, the rates and routes of colonizations with Staphylococcus aureus, Streptococcus groups A, B, C, F, and G and Pseudomonas aeruginosa were examined. The exogenous colonization rates were, with S. aureus 77%, with Streptococcus species 52% and with Ps. aeruginosa 32%. The colonization rate with Ps. aeruginosa was higher in patients with larger burns. Patients dispersed Streptococcus and Ps. aeruginosa as well as S. aureus into the air of their rooms in considerable amounts, but dispersers were not more important as sources of cross-colonization than non-dispersers. In comparison of clothing routines, there was no difference in overall colonization rates. The newly designed barrier garment that was made from apparently particle-tight material did not reduce the transfer of bacteria from patient to patient. A less rigid routine than that previously used did not increase the risk of cross-contamination. A thorough change of barrier dress after close contact nursing delayed the first exogenous S. aureus colonization from day 6 to day 14 after admission. This routine might be recommended for clinical use. Otherwise, methods must be developed for adequate selection of materials intended for barrier garments. Images Plate 1 PMID:109498

  1. A multifocal outbreak of hepatitis A traced to commercially distributed lettuce.

    PubMed Central

    Rosenblum, L S; Mirkin, I R; Allen, D T; Safford, S; Hadler, S C

    1990-01-01

    From February 1 through March 20, 1988, 202 cases of hepatitis A were reported in and around Jefferson County, Kentucky. The epidemic curve indicated a common-source exposure. However, there was no apparent single source of exposure from a restaurant, or community gathering; nor was there a geographic clustering by residence. Cases were mainly adults 20-59 years old (89 percent); 51 percent were female. A case-control study using neighborhood controls found that factors associated with hepatitis A were: having eaten downtown (odds ratio [OR] = 4.0) and having dined at any one of three restaurants (OR = 21.0). Case-control studies of patrons of two of these restaurants found that eating green salad was strongly associated with acquiring hepatitis A: OR = 11.6 and OR = 4.4. The three implicated restaurants accounted for 71 percent of the cases. All three restaurants were supplied by the same fresh produce distributor; however, investigation suggested that contamination most likely occurred prior to local distribution. This outbreak of hepatitis A is the first in the United States apparently associated with fresh produce contaminated before distribution to restaurants, and raises important public health issues regarding the regulation of fresh produce. PMID:2382744

  2. Report on the remedial investigation of Bear Creek Valley at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 5: Appendix F -- Baseline human health risk assessment report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-09-01

    This Remedial Investigation (RI) Report characterizes the nature and extent of contamination, evaluates the fate and transport of contaminants, and assesses risk to human health and the environment resulting from waste disposal and other US Department of Energy (DOE) operations in Bear Creek Valley (BCV). BCV, which is located within the DOE Oak Ridge Reservation (ORR) encompasses multiple waste units containing hazardous and radioactive wastes arising from operations at the adjacent Oak Ridge Y-12 Plant. The primary waste units discussed in this RI Report are the S-3 Site, Oil Landfarm (OLF), Boneyard/Burnyard (BYBY), Sanitary Landfill 1 (SL 1), and Bearmore » Creek Burial Grounds (BCBG). These waste units, plus the contaminated media resulting from environmental transport of the wastes from these units, are the subject of this RI. This BCV RI Report represents the first major step in the decision-making process for the BCV watershed. The RI results, in concert with the follow-on FS will form the basis for the Proposed Plan and Record of Decision for all BCV sites. This comprehensive decision document process will meet the objectives of the watershed approach for BCV. Appendix F documents potential risks and provides information necessary for making remediation decisions. A quantitative analysis of the inorganic, organic, and radiological site-related contaminants found in various media is used to characterize the potential risks to human health associated with exposure to these contaminants.« less

  3. Cryptosporidium surveillance and risk factors in the United States.

    PubMed

    Yoder, Jonathan S; Beach, Michael J

    2010-01-01

    Surveillance for Cryptosporidium in the United States indicates that the reported incidence of infection has increased dramatically since 2004. The reasons for this increase are unclear but might be caused by an actual increase in incidence, improved surveillance, improved awareness about cryptosporidiosis, and/or increases in testing practices resulting from the licensing of the first-ever treatment for cryptosporidiosis. While regional differences remain, the incidence of cryptosporidiosis appears to be increasing across the United States. Onset of illness is most common during the summer, particularly among younger children. Cryptosporidiosis case reporting also influences outbreak detection and reporting; the recent rise in cases coincides with an increase in the number of reported cryptosporidiosis outbreaks, particularly in treated recreational water venues. Risk factors include ingesting contaminated recreational or drinking water, exposure to infected animals, having close contacts with cryptosporidiosis, travel to disease-endemic areas, and ingestion of contaminated food. Advances in molecular characterization of clinical specimens have improved our understanding of the changing epidemiology and risk factors. Prevention and control of cryptosporidiosis requires continued efforts to interrupt the transmission of Cryptosporidium through water, food, and contact with infected persons or animals. Of particular importance is continued improvement and monitoring of drinking water treatment and advances in the design, operation, and management of recreational water venues coupled with behavioral changes among the swimming public. Published by Elsevier Inc.

  4. Internal contamination in the space station

    NASA Technical Reports Server (NTRS)

    Poythress, C.

    1985-01-01

    Atmosphere trace contaminant control systems used in the past (Lunar Module and Skylab) and present (nuclear submarines and Shuttle) are discussed. Recommendations are made for the future Space Station contaminant control system. The prevention and control methods used are judicious material selection, detection, and specific removal equipment. Sources and effects of contamination relating to crew and equipment are also discussed.

  5. Electron Beam Technology for Environmental Pollution Control.

    PubMed

    Chmielewski, Andrzej G; Han, Bumsoo

    2016-10-01

    Worldwide, there are over 1700 electron beam (EB) units in commercial use, providing an estimated added value to numerous products, amounting to 100 billion USD or more. High-current electron accelerators are used in diverse industries to enhance the physical and chemical properties of materials and to reduce undesirable contaminants such as pathogens, toxic byproducts, or emissions. Over the past few decades, EB technologies have been developed aimed at ensuring the safety of gaseous and liquid effluents discharged to the environment. It has been demonstrated that EB technologies for flue gas treatment (SO x and NO x removal), wastewater purification, and sludge hygienization can be effectively deployed to mitigate environmental degradation. Recently, extensive work has been carried out on the use of EB for environmental remediation, which also includes the removal of emerging contaminants such as VOCs, endocrine disrupting chemicals (EDCs), and potential EDCs.

  6. Fishing a superfund site: Dissonance and risk perception of environmental hazards by fishermen in Puerto Rico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burger, J.; Gochfeld, M.

    1991-06-01

    Risk perception studies show that individuals tend to underestimate significant risks, overestimate negligible ones, and distrust authorities. They also rely on a variety of strategies or heuristics to reach decisions regarding their risk-taking behavior. The authors report on a survey of fishermen and crabbers engaged in recreational and substance fishing in a Puerto Rican estuary (near Humacao), which has been declared a Superfund site because of suspected contamination by mercury, and at ecologically similar control sites. Nearly everyone interviewed at the Humacao site was aware of the mercury contamination, but either denied its importance, believed the contamination was restricted tomore » a distant part of the estuary, or assumed that the estuary would be closed by the authorities if the threat was real. All site-users consumed the fish and crabs they caught. At Humacao, the average catch was 7 fish per fishermen (mostly tilapia, Tilapia mossambica, and tarpon, Megalops atlantica) and 13 crabs per crabber (all blue crabs, Callinectes sapidus). On average, the site-users returned to the lagoons about 3-4 times per month. At control sites, fewer fish were eaten. The worst case consumption of tarpon, a species which concentrated mercury at Eastern Puerto Rico, provided an exposure exceeding the EPA reference dose, whereas consumption of one tarpon per week did not entail excess exposure. Fortunately, few individuals caught tarpon exclusively. Unlike counterparts in the northeastern United States, they trusted authorities and indicated that they would have heeded warnings of mercury contamination posted where they fished.« less

  7. Development of a preprototype trace contaminant control system. [for space stations

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The steady state contaminant load model based on shuttle equipment and material test programs, and on the current space station studies was revised. An emergency upset contaminant load model based on anticipated emergency upsets that could occur in an operational space station was defined. Control methods for the contaminants generated by the emergency upsets were established by test. Preliminary designs of both steady state and emergency contaminant control systems for the space station application are presented.

  8. An assessment on the environmental contamination caused by the Fukushima accident.

    PubMed

    Song, Jin Ho

    2018-01-15

    The radiological releases from the damaged fuel to the atmosphere and into the cooling water in the Fukushima Daiich Nuclear Power Plant (FDNPP) accident are investigated. Atmospheric releases to the land and ocean mostly occurred during the first week after the accident whereas continuous release from the damaged fuel into the cooling water resulted in an accumulation of contaminated water in the plant during last six years. An evaluation of measurement data and analytical model for the release of radionuclides indicated that atmospheric releases were mainly governed by the volatility of the radionuclides. Using the measurement data on the contaminated water, the mechanism for the release of long-lived radionuclides into the cooling water was analyzed. It was found that the radioactivity concentrations of 90 Sr in the contaminated water in the Primary Containment Vessel (PCV) of unit 2 and unit 3 were consistently higher than that of 137 Cs and the radioactivity concentration of 90 Sr in the turbine building of unit 1 in year 2015 was higher than that in year 2011. It was also observed that the radioactivity concentration of long-lived radionuclides in the contaminated water in the FDNPP is still high even in year 2015. The activity ratio of 238 Pu/ 239+240 Pu for the contaminated water was in the range of 1.7-5.4, which was significantly different from the ratios from the soil samples representing the atmospheric releases of FDNPP. It is concluded that the release mechanisms into the atmosphere and cooling water are clearly different and there has been significant amount of long-lived radionuclides released into the contaminated water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty.

    PubMed

    Sossai, D; Dagnino, G; Sanguineti, F; Franchin, F

    2011-12-01

    Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m(3)) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m(3) without the LAF to 3.5 CFU/m(3) with the LAF (P < 0.0001), which is below the suggested limit for an OR with ultraclean laminar ventilation. There were no significant differences in the mean bacterial count in the instrument table area: 28.6 CFU/m(3) were recorded with the LAF (N = 6) unit and 30.8 CFU/m(3) (N = 6) without the LAF unit (P = 0.631). During six operations with LAF and six without LAF, particle counts were performed and the number of 0.5 μm particles was analyzed. The particle counts decreased significantly when the LAF unit was used (P = 0.003). When a mobile LAF unit was added to the standard OR ventilation, bacterial contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections.

  10. Investigation of Ground-Water Contamination at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina

    USGS Publications Warehouse

    Vroblesky, Don A.; Casey, Clifton C.; Petkewich, Matthew D.; Lowery, Mark A.; Conlon, Kevin J.; Harrelson, Larry G.

    2007-01-01

    The U.S. Geological Survey and the Naval Facilities Engineering Command Southeast investigated natural and engineered remediation of chlorinated volatile organic compound ground-water contamination at Solid Waste Management Unit 12 at the Naval Weapons Station Charleston, North Charleston, South Carolina. The primary contaminants of interest are tetrachloroethene, 1,1,1-trichloroethane, trichloroethene, cis-1,2-dichloroethene, vinyl chloride, 1,1-dichloroethane, and 1,1-dichloroethene. In general, the hydrogeology of Solid Waste Management Unit 12 consists of a surficial aquifer, composed of sand to clayey sand, overlain by dense clay that extends from about land surface to a depth of about 8 to 10 feet and substantially limits local recharge. During some months in the summer, evapotranspiration and limited local recharge result in ground-water level depressions in the forested area near wells 12MW-12S and 12MW-17S, seasonally reflecting the effects of evapotranspiration. Changes in surface-water levels following Hurricane Gaston in 2004 resulted in a substantial change in the ground-water levels at the site that, in turn, may have caused lateral shifting of the contaminant plume. Hydraulic conductivity, determined by slug tests, is higher along the axis of the plume in the downgradient part of the forests than adjacent to the plume, implying that there is some degree of lithologic control on the plume location. Hydraulic conductivity, hydraulic gradient, sulfur-hexafluoride measurements, and historical data indicate that ground-water flow rates are substantially slower in the forested area relative to upgradient areas. The ground-water contamination, consisting of chlorinated volatile organic compounds, extends eastward in the surficial aquifer from the probable source area near a former underground storage tank. Engineered remediation approaches include a permeable reactive barrier and phytoremediation. The central part of the permeable reactive barrier along the main axis of the contaminant plume appears to be actively removing contamination; however, ground-water contamination is moving around the southern end of the permeable reactive barrier. Changes in the contaminant concentrations along the path of ground-water transport reflect a complex variety of influences. Potential influences include dechlorination, sorption and desorption, transpirative removal by trees, lateral shifting of the plume, and the presence of zones of differing concentrations possibly reflecting one or more pulse releases of contamination from the source area. Near the source area at well 12MW-10S, volatile organic compound concentrations of cis-1,2-dichlorothene, vinyl chloride, 1,1-dichloroethane, and 1,1,1-trichloroethane continued an irregular decline, while tetrachloroethene and 1,1-dichloroethene showed marked fluctuations in concentration during 2005 and 2006. Volatile organic compound concentrations at well 12MW-03S continued to show decreasing concentrations with the June 2006 concentrations being the lowest yet recorded at that well for several volatile organic compounds. Concentration and delta carbon 13 data indicate that in the upgradient part of the plume, tetrachloroethene is being degraded to trichloroethene, which is being degraded to cis-1,2-dichloroethene, and cis-1,2-dichloroethene is accumulating faster than it is being depleted. Ground-water volatile organic compound concentrations also changed in some wells in the forested area in the midpart of the plume. Increasing tetrachloroethene and decreasing trichloroethene and 1,1-dichloroethene concentrations were observed at wells 12MW-05S and 12MW-29S, possibly reflecting a lateral shift in the axis of the contamination plume or an advancing contamination pulse. Substantial decreases in contamination occur in the forested area downgradient from well 12MW-05S. Probable major loss mechanisms in this area include evapotranspiration and sorption.

  11. Linking field-based metabolomics and chemical analyses to prioritize contaminants of emerging concern in the Great Lakes basin.

    PubMed

    Davis, John M; Ekman, Drew R; Teng, Quincy; Ankley, Gerald T; Berninger, Jason P; Cavallin, Jenna E; Jensen, Kathleen M; Kahl, Michael D; Schroeder, Anthony L; Villeneuve, Daniel L; Jorgenson, Zachary G; Lee, Kathy E; Collette, Timothy W

    2016-10-01

    The ability to focus on the most biologically relevant contaminants affecting aquatic ecosystems can be challenging because toxicity-assessment programs have not kept pace with the growing number of contaminants requiring testing. Because it has proven effective at assessing the biological impacts of potentially toxic contaminants, profiling of endogenous metabolites (metabolomics) may help screen out contaminants with a lower likelihood of eliciting biological impacts, thereby prioritizing the most biologically important contaminants. The authors present results from a study that utilized cage-deployed fathead minnows (Pimephales promelas) at 18 sites across the Great Lakes basin. They measured water temperature and contaminant concentrations in water samples (132 contaminants targeted, 86 detected) and used 1 H-nuclear magnetic resonance spectroscopy to measure endogenous metabolites in polar extracts of livers. They used partial least-squares regression to compare relative abundances of endogenous metabolites with contaminant concentrations and temperature. The results indicated that profiles of endogenous polar metabolites covaried with at most 49 contaminants. The authors identified up to 52% of detected contaminants as not significantly covarying with changes in endogenous metabolites, suggesting they likely were not eliciting measurable impacts at these sites. This represents a first step in screening for the biological relevance of detected contaminants by shortening lists of contaminants potentially affecting these sites. Such information may allow risk assessors to prioritize contaminants and focus toxicity testing on the most biologically relevant contaminants. Environ Toxicol Chem 2016;35:2493-2502. Published 2016 Wiley Periodicals Inc. on behalf of SETAC. This article is a US Government work and, as such, is in the public domain in the United States of America. Published 2016 Wiley Periodicals Inc. on behalf of SETAC. This article is a US Government work and, as such, is in the public domain in the United States of America.

  12. Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses.

    PubMed

    Boyd, Thomas J; Montgomery, Michael T; Cuenca, Richard H; Hagimoto, Yutaka

    2016-10-21

    A method is described which uses the absence of radiocarbon in industrial chemicals and fuels made from petroleum feedstocks which frequently contaminate the environment. This radiocarbon signal - or rather the absence of signal - is evenly distributed throughout a contaminant source pool (unlike an added tracer) and is not impacted by biological, chemical or physical processes (e.g., the 14 C radioactive decay rate is immutable). If the fossil-derived contaminant is fully degraded to CO2, a harmless end-product, that CO2 will contain no radiocarbon. CO2 derived from natural organic matter (NOM) degradation will reflect the NOM radiocarbon content (usually <30,000 years old). Given a known radiocarbon content for NOM (a site background), a two end-member mixing model can be used to determine the CO2 derived from a fossil source in a given soil gas or groundwater sample. Coupling the percent CO2 derived from the contaminant with the CO2 respiration rate provides an estimate for the total amount of contaminant degraded per unit time. Finally, determining a zone of influence (ZOI) representing the volume from which site CO2 is collected allows determining the contaminant degradation per unit time and volume. Along with estimates for total contaminant mass, this can ultimately be used to calculate time-to-remediate or otherwise used by site managers for decision-making.

  13. Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses

    PubMed Central

    Boyd, Thomas J.; Montgomery, Michael T.; Cuenca, Richard H.; Hagimoto, Yutaka

    2016-01-01

    A method is described which uses the absence of radiocarbon in industrial chemicals and fuels made from petroleum feedstocks which frequently contaminate the environment. This radiocarbon signal — or rather the absence of signal — is evenly distributed throughout a contaminant source pool (unlike an added tracer) and is not impacted by biological, chemical or physical processes (e.g., the 14C radioactive decay rate is immutable). If the fossil-derived contaminant is fully degraded to CO2, a harmless end-product, that CO2 will contain no radiocarbon. CO2 derived from natural organic matter (NOM) degradation will reflect the NOM radiocarbon content (usually <30,000 years old). Given a known radiocarbon content for NOM (a site background), a two end-member mixing model can be used to determine the CO2 derived from a fossil source in a given soil gas or groundwater sample. Coupling the percent CO2 derived from the contaminant with the CO2 respiration rate provides an estimate for the total amount of contaminant degraded per unit time. Finally, determining a zone of influence (ZOI) representing the volume from which site CO2 is collected allows determining the contaminant degradation per unit time and volume. Along with estimates for total contaminant mass, this can ultimately be used to calculate time-to-remediate or otherwise used by site managers for decision-making. PMID:27805601

  14. Giardiasis outbreaks in the United States, 1971–2011

    PubMed Central

    Adam, E. A.; Yoder, J. S.; Gould, L. H.; Hlavsa, M. C.; Gargano, J. W.

    2016-01-01

    Summary Giardia intestinalis is the leading parasitic aetiology of human enteric infections in the United States, with an estimated 1.2 million cases occurring annually. To better understand transmission, we analysed data on all giardiasis outbreaks reported to the Centers for Disease Control and Prevention for 1971–2011. The 242 outbreaks, affecting ∼41 000 persons, resulted from waterborne (74.8%), foodborne (15.7%), person-to-person (2.5%), and animal contact (1.2%) transmission. Most (74.6%) waterborne outbreaks were associated with drinking water, followed by recreational water (18.2%). Problems with water treatment, untreated groundwater, and distribution systems were identified most often during drinking water-associated outbreak investigations; problems with water treatment declined after the 1980s. Most recreational water-associated outbreaks were linked to treated swimming venues, with pools and wading pools implicated most often. Produce was implicated most often in foodborne outbreaks. Additionally, foods were most commonly prepared in a restaurant and contaminated by a food handler. Lessons learned from examining patterns in outbreaks over time can help prevent future disease. Groundwater and distribution system vulnerabilities, inadequate pool disinfection, fruit and vegetable contamination, and poor food handler hygiene are promising targets for giardiasis prevention measures. PMID:26750152

  15. Chlorinated solvents in groundwater of the United States

    USGS Publications Warehouse

    Moran, M.J.; Zogorski, J.S.; Squillace, P.J.

    2007-01-01

    Four chlorinated solvents-methylene chloride, perchloroethene (PCE), 1,1,1-trichloroethane, and trichloroethene (TCE)-were analyzed in samples of groundwater taken throughout the conterminous United States by the U.S. Geological Survey. The samples were collected between 1985 and 2002 from more than 5,000 wells. Of 55 volatile organic compounds (VOCs) analyzed in groundwater samples, solvents were among the most frequently detected. Mixtures of solvents in groundwater were common and may be the result of common usage of solvents or degradation of one solvent to another. Relative to other VOCs with Maximum Contaminant Levels (MCLs), PCE and TCE ranked high in terms of the frequencies of concentrations greater than or near MCLs. The probability of occurrence of solvents in groundwater was associated with dissolved oxygen content of groundwater, sources such as urban land use and population density, and hydraulic properties of the aquifer. The results reinforce the importance of understanding the redox conditions of aquifers and the hydraulic properties of the saturated and vadose zones in determining the intrinsic susceptibility of groundwater to contamination by solvents. The results also reinforce the importance of controlling sources of solvents to groundwater. ?? 2007 American Chemical Society.

  16. Development of a sorber trace contaminant control system including pre- and post-sorbers for a catalytic oxidizer

    NASA Technical Reports Server (NTRS)

    Olcott, T. M.

    1972-01-01

    A general methodology was developed for spacecraft contaminant control system design. Elements considered for contaminant control were catalytic oxidation with isotope or electrical heat and pre- and post-sorbers, charcoal with regeneration and non-regeneration, and reactive constituents. A technique is described for sizing a charcoal bed for a multiple contaminant load.

  17. Air contamination for predicting wound contamination in clean surgery: A large multicenter study.

    PubMed

    Birgand, Gabriel; Toupet, Gaëlle; Rukly, Stephane; Antoniotti, Gilles; Deschamps, Marie-Noelle; Lepelletier, Didier; Pornet, Carole; Stern, Jean Baptiste; Vandamme, Yves-Marie; van der Mee-Marquet, Nathalie; Timsit, Jean-François; Lucet, Jean-Christophe

    2015-05-01

    The best method to quantify air contamination in the operating room (OR) is debated, and studies in the field are controversial. We assessed the correlation between 2 types of air sampling and wound contaminations before closing and the factors affecting air contamination. This multicenter observational study included 13 ORs of cardiac and orthopedic surgery in 10 health care facilities. For each surgical procedure, 3 microbiologic air counts, 3 particles counts of 0.3, 0.5, and 5 μm particles, and 1 bacteriologic sample of the wound before skin closure were performed. We collected data on surgical procedures and environmental characteristics. Of 180 particle counts during 60 procedures, the median log10 of 0.3, 0.5, and 5 μm particles was 7 (interquartile range [IQR], 6.2-7.9), 6.1 (IQR, 5.4-7), and 4.6 (IQR, 0-5.2), respectively. Of 180 air samples, 50 (28%) were sterile, 90 (50%) had 1-10 colony forming units (CFU)/m(3) and 40 (22%) >10 CFU/m(3). In orthopedic and cardiac surgery, wound cultures at closure were sterile for 24 and 9 patients, 10 and 11 had 1-10 CFU/100 cm(2), and 0 and 6 had >10 CFU/100 cm(2), respectively (P < .01). Particle sizes and a turbulent ventilation system were associated with an increased number of air microbial counts (P < .001), but they were not associated with wound contamination (P = .22). This study suggests that particle counting is a good surrogate of airborne microbiologic contamination in the OR. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Engineering Hyporheic Zones to Attenuate Heavy Metals in Constructed Urban Streams: Performance Data from Constructed Stream Flumes

    NASA Astrophysics Data System (ADS)

    Halpin, B. N.; Portmann, A. C.; Herzog, S.; Higgins, C.; McCray, J. E.

    2017-12-01

    Urban stormwater runoff is a major cause of water quality impairment along ocean shorelines and in rivers, lakes and estuaries across the United States. In addition to pathogens, nutrients, and organic contaminants, a variety of heavy metals are commonly found at elevated concentrations in urban runoff. Although such metals occur in both dissolved and particulate-bound phases, conventional stormwater controls are typically designed to remove suspended solids, while dissolved phase contaminants remain largely untreated. To address this gap in available stormwater controls, a novel technology, termed Biohydrochemical Enhancements for Streamwater Treatment (BEST), has been developed based on inspiration from the natural hyporheic zone (HZ). BEST utilizes a series of alternating streambed permeabilities to drive efficient surface water-HZ exchange. This is combined with reactive and/or sorptive streambed geomedia designed to remove dissolved phase contaminants from constructed urban drainage channels. Previous research at the Colorado School of Mines has shown that a 15-meter flume modified with BEST exhibits greater hyporheic exchange than an all-sand control flume, though both flumes provided greater contaminant attenuation than a selection of actual urban streams. This study again utilized the 15-meter flumes at Colorado School of Mines to evaluate two configurations of BEST for removal of heavy metals commonly found in stormwater runoff, including cadmium, copper, nickel, lead and zinc. In both BEST configurations, the geomedia consisted of a 30/70 (v/v) mix of woodchips and sand, with one configuration using coarse sand (K=0.48 cm/s) and the other using finer sand (K=0.16 cm/s). Both configurations were compared to an all-sand control. To evaluate metals removal, a suite of aqueous metals solution was spiked into each flume, and aqueous concentrations of the five metals of interest were monitored in both the surface and pore water over 24 hours. Differences in hyporheic exchange and residence times, as well as redox conditions, between the BEST configurations and the control impacted heavy metals retention in the engineered streambeds. Overall, engineered hyporheic zones in small urban drainage channels may be a promising option for retaining heavy metals collected by urban stormwater runoff.

  19. Practical measures for reducing the risk of environmental contamination in shale energy production.

    PubMed

    Ziemkiewicz, Paul; Quaranta, John D; McCawley, Michael

    2014-07-01

    Gas recovery from shale formations has been made possible by advances in horizontal drilling and hydraulic fracturing technology. Rapid adoption of these methods has created a surge in natural gas production in the United States and increased public concern about its environmental and human health effects. We surveyed the environmental literature relevant to shale gas development and studied over fifteen well sites and impoundments in West Virginia to evaluate pollution caused by air emissions, light and noise during drilling. Our study also characterized liquid and solid waste streams generated by drilling and hydraulic fracturing and evaluated the integrity of impoundments used to store fluids produced by hydraulic fracturing. While most shale gas wells are completed with little or no environmental contamination, we found that many of the problems associated with shale gas development resulted from inattention to accepted engineering practices such as impoundment construction, improper liner installation and a lack of institutional controls. Recommendations are provided based on the literature and our field studies. They will address not all but a great many of the deficiencies that result in environmental release of contaminants from shale gas development. We also identified areas where new technologies are needed to fully address contaminant releases to air and water.

  20. Exogenous bacterial contamination of donor blood.

    PubMed

    Rock, G; Westwood, J C

    1977-05-07

    The Canadian Red Cross blood transfusion service has followed a set protocol for phlebotomy and collection of a unit of blood. Recent requirements for automated testing have necessitated that a second tube of blood be obtained from the blood line following collection of the unit. Evaluation of the techniques used, however, has indicated the possibility of bacterial contamination from the skin of donors, from insertion of the needle through an unsterile rubber stopper, and through backflow from a nonsterile vacuum tube. To test these possibilities swabs were taken from skin and stoppers of vacuum tubes. Further, vacuum tubes were deliberately contaminated with Escherichia coli. The normal sampling procedure, which involves stripping the donor line to refill and mix the blood, was then followed. This resulted in contamination of the segments and even the blood bag. These findings led to modification of the standard bleeding technique, whereby stripping was eliminated and sterile vacuum tubes were to be used at all times.

  1. Probability of nitrate contamination of recently recharged groundwaters in the conterminous United States

    USGS Publications Warehouse

    Nolan, B.T.; Hitt, K.J.; Ruddy, B.C.

    2002-01-01

    A new logistic regression (LR) model was used to predict the probability of nitrate contamination exceeding 4 mg/L in predominantly shallow, recently recharged ground waters of the United States. The new model contains variables representing (1) N fertilizer loading (p 2 = 0.875), indicating that the LR model fits the data well. The likelihood of nitrate contamination is greater in areas with high N loading and well-drained surficial soils over unconsolidated sand and gravels. The LR model correctly predicted the status of nitrate contamination in 75% of wells in a validation data set. Considering all wells used in both calibration and validation, observed median nitrate concentration increased from 0.24 to 8.30 mg/L as the mapped probability of nitrate exceeding 4 mg/L increased from less than or equal to 0.17 to > 0.83.

  2. Changes in Groundwater Flow and Volatile Organic Compound Concentrations at the Fischer and Porter Superfund Site, Warminster Township, Bucks County, Pennsylvania, 1993-2009

    USGS Publications Warehouse

    Sloto, Ronald A.

    2010-01-01

    The 38-acre Fischer and Porter Company Superfund Site is in Warminster Township, Bucks County, Pa. Historically, as part of the manufacturing process, trichloroethylene (TCE) degreasers were used for parts cleaning. In 1979, the Bucks County Health Department detected TCE and other volatile organic compounds (VOCs) in water from the Fischer and Porter on-site supply wells and nearby public-supply wells. The Fischer and Porter Site was designated as a Superfund Site and placed on the National Priorities List in September 1983. A 1984 Record of Decision for the site required the Fischer and Porter Company to pump and treat groundwater contaminated by VOCs from three on-site wells at a combined rate of 75 gallons per minute to contain groundwater contamination on the property. Additionally, the Record of Decision recognized the need for treatment of the water from two nearby privately owned supply wells operated by the Warminster Heights Home Ownership Association. In 2004, the Warminster Heights Home Ownership Association sold its water distribution system, and both wells were taken out of service. The report describes changes in groundwater levels and contaminant concentrations and migration caused by the shutdown of the Warminster Heights supply wells and presents a delineation of the off-site groundwater-contamination plume. The U.S. Geological Survey (USGS) conducted this study (2006-09) in cooperation with the U.S. Environmental Protection Agency (USEPA). The Fischer and Porter Site and surrounding area are underlain by sedimentary rocks of the Stockton Formation of Late Triassic age. The rocks are chiefly interbedded arkosic sandstone and siltstone. The Stockton aquifer system is comprised of a series of gently dipping lithologic units with different hydraulic properties. A three-dimensional lithostratigraphic model was developed for the site on the basis of rock cores and borehole geophysical logs. The model was simplified by combining individual lithologic units into generalized units representing upward fining sedimentary cycles capped by a siltstone bed. These cycles were labeled units 1 through 8 and are called stratigraphic units in this report. Groundwater in the unweathered zone mainly moves through a network of interconnecting secondary openings--bedding-plane fractures and joints. Groundwater generally is unconfined in the shallower part of the aquifer and confined or semiconfined in the deeper part of the aquifer. The migration of VOCs from the Fischer and Porter Site source area is influenced by geologic and hydrologic controls. The hydrologic controls have changed with time. Stratigraphic units 2 and 3 crop out beneath the former Fischer and Porter plant. VOCs originating at the plant source area entered these stratigraphic units and moved downdip to the northwest. When the wells at and in the vicinity of the site were initially sampled in 1979-80, three public-supply wells (BK-366, BK-367, MG-946) and three industrial-supply wells (BK-368, BK-370, and BK-371) were pumping. Groundwater contaminated with VOCs flowed downdip and then northeast along strike toward well BK-366, downdip toward well BK-368, and downdip and then west along strike toward well MG-946. The long axis of the TCE plume is oriented about N. 18? W. in the direction of dip. In 1979-80, the leading edge of the plume was about 3,500 feet wide. With the cessation of pumping of the supply wells in 2004, the size of the plume has decreased. In 2007-09, the plume was approximately 2,000 feet long and 2,000 feet wide at the leading edge. On the western side of the site, TCE and tetrachloroethylene (PCE) appear to be moving downdip though stratigraphic unit 3. The downdip extent of TCE and PCE migration extended approximately 550 feet off-site to the northwest and 750 feet off-site to the north. TCE concentrations in water samples from wells at the western site boundary increased from 1996 to 2007. On the northern side of the site, TCE and P

  3. Requirements and Sizing Investigation for Constellation Space Suit Portable Life Support System Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.; Jennings, Mallory A.; Waguespack, Glenn

    2010-01-01

    The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Constellation Space Suit Portable Life Support System (PLSS), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for Constellation Space Suit System (CSSS) pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

  4. State of the Science Review: Potential for Beneficial Use of Waste By-Products for In-situ Remediation of Metal-Contaminated Soil and Sediment

    EPA Science Inventory

    Metal and metalloid contamination of soil and sediment is a widespread problem both in urban and rural areas throughout the United States (U.S. EPA, 2014). Beneficial use of waste by-products as amendments to remediate metal-contaminated soils and sediments can provide major eco...

  5. Superfund Record of Decision (EPA Region 6): Cimarron Mining Corporation site, Operable Unit 1, Lincoln County, Carrizozo, NM. (First remedial action), September 1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-09-21

    The 10.6-acre Cimarron Mining site, Lincoln County, New Mexico, is an inactive milling facility used to recover iron from ores transported to the site. A shallow aquifer, which is not a potential drinking water source, and a deeper primary drinking water aquifer lie beneath the site. Cyanide was used until 1982 to recover precious metals. The operation of the mill resulted in the discharge of contaminated liquids onsite. The sources of environmental cyanide contamination at the site are the processed waste materials, including tailings piles and cinder block trench sediment piles, the cyanide solution and tailings spillage areas, and themore » cyanide solution recycling and disposal areas, including cinder block trenches and an unlined discharge pit. The major sources of ground water contamination by cyanide are the cinder block trenches and the discharge pit. These areas of prolonged contact between cyanide solution and underlying soil led to cyanide contamination in the shallow aquifer. The ROD addresses contaminated shallow ground water at the Cimarron Mining mill area as Operable Unit 1 (OU1). The primary contaminants of concern affecting the ground water are inorganics including cyanide.« less

  6. Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 415: Project 57 No. 1 Plutonium Dispersion (NTTR), Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, Patrick; Burmeister, Mark

    2014-04-01

    This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 415, Project 57 No. 1 Plutonium Dispersion (NTTR). CAU 415 is located on Range 4808A of the Nevada Test and Training Range (NTTR) and consists of one corrective action site: NAFR-23-02, Pu Contaminated Soil. The CAU 415 site consists of the atmospheric release of radiological contaminants to surface soil from the Project 57 safety experiment conducted in 1957. The safety experiment released plutonium (Pu), uranium (U), and americium (Am) to the surface soil over an area of approximately 1.9 squaremore » miles. This area is currently fenced and posted as a radiological contamination area. Vehicles and debris contaminated by the experiment were subsequently buried in a disposal trench within the surface-contaminated, fenced area and are assumed to have released radiological contamination to subsurface soils. Potential source materials in the form of pole-mounted electrical transformers were also identified at the site and will be removed as part of closure activities.« less

  7. Ventilator-associated pneumonia risk decreased by use of oral moisture gel in oral health care.

    PubMed

    Takeyasu, Yoshihiro; Yamane, Gen-Yuki; Tonogi, Morio; Watanabe, Yutaka; Nishikubo, Shuichi; Serita, Ryohei; Imura, Kumiko

    2014-01-01

    Although oral health care has a preventive effect against ventilator-associated pneumonia (VAP), the most effective method of oral health care in this respect remains to be established. The objective of this single-center, randomized, controlled trial was to investigate the relationship between VAP and various methods of oral health care. All patients included in the study (n=142) were on mechanical ventilation with oral intubation at the intensive care unit of the Tokyo Dental College Ichikawa General Hospital. They were divided into two groups, one receiving standard oral health care (Standard group), and the other receiving oral health care using an oral moisture gel instead of water (Gel group). After removal of the intubation tube, biofilm on cuff of the tube was stained with a disclosing agent to determine the contamination level. Factors investigated included sex, age, number of remaining teeth, intubation time, fever ≥38.5°C, VAP, cuff contamination level, and time required for one oral health care session. No VAP occurred in either group during the study period. The level of cuff contamination was significantly lower in the Gel group than the Standard group, and the time required for one session of oral health care was shorter (p<0.001). Multivariate analysis revealed use of the oral moisture gel as a factor affecting cuff contamination level. Use of an oral moisture gel decreased invasion of the pharynx by bacteria and contaminants together with biofilm formation on the intubation tube cuff. These results suggest that oral health care using an oral moisture gel is effective in preventing cuff contamination.

  8. Inactivation of infectious hepatitis E virus present in commercial pig livers sold in local grocery stores in the United States.

    PubMed

    Feagins, A R; Opriessnig, T; Guenette, D K; Halbur, P G; Meng, X J

    2008-03-31

    Hepatitis E virus (HEV) is a zoonotic pathogen and pigs are a known reservoir. Recently we showed that approximately 11% of commercial pig livers sold in local U.S. grocery stores for food consumptions are contaminated by infectious HEV. In this study, a swine bioassay was used to determine if the infectious HEV in contaminated commercial pig livers could be inactivated by traditional cooking methods. Group 1 pigs (n=5) were each inoculated intravenously (i.v.) with a HEV-negative liver homogenate as negative controls, group 2 pigs (n=5) were each inoculated i.v. with a pool of two HEV-positive pig liver homogenates as positive controls, groups 3, 4 and 5 pigs (n=5, each group) were each inoculated i.v. with a pool of homogenates of two HEV-positive livers incubated at 56 degrees C for 1 h, stir-fried at 191 degrees C (internal temperature of 71 degrees C) for 5 min or boiled in water for 5 min, respectively. As expected, the group 2 positive control pigs all became infected whereas the group 1 negative control pigs remained negative. Four of the five pigs inoculated with HEV-positive liver homogenates incubated at 56 degrees C for 1 h also became infected. However, pigs in groups 4 and 5 did not become infected. The results indicated that HEV in contaminated commercial pig livers can be effectively inactivated if cooked properly, although incubation at 56 degrees C for 1 h cannot inactivate the virus. Thus, to reduce the risk of food-borne HEV transmission, pig livers must be thoroughly cooked.

  9. The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples.

    PubMed

    Batt, Angela L; Furlong, Edward T; Mash, Heath E; Glassmeyer, Susan T; Kolpin, Dana W

    2017-02-01

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. Published by Elsevier B.V.

  10. Superfund record of decision (EPA Region 1): Otis Air National Guard (USAF), Operable Unit 5, Falmouth, MA, September 30, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1999-03-01

    This decision document presents the Air Force Center for Environmental Excellence (AFCEE) selected remedial action decisions for contaminant source areas at the following Areas of Contamination (AOCs) at the Massachusetts Military Reservation (MMR) in Barnstable County on Cape Cod, Massachusetts: Fire Training Area No. 2 and Landfill No. 2 (FTA-2/LF-2); Petroleum Fuels Storage Area, Fuel Spill No. 10, and Fuel Spill No. 11 (PFSA/FS-10/FS-11); Storm Drainage Ditch No. 2, Fuel Spill No. 6, and Fuel Spill No. 8 (SD-2/FS-6/FS-8); Storm Drainage Ditch No. 2, Fire Training Area No. 3, and Coal Storage Yard No. 4 (SF-3/FTA-3/CY-4); Storm Drainage Ditch No.more » 4 (SD-4); and Storm Drainage Ditch No. 5 and Fuel Spill No. 5 (SD-5/FS-5). The selected remedy for AOC FTA-2/LF-2 is Biosparging with Ambient Air Monitoring. This remedial action is a source control action that addresses leaching of organic compounds to groundwater, the principal known threat at AOC FTA-2/LF-2. It consists of designing, constructing, and operating a biosparging treatment system, maintaining institutional controls, and five-year reviews of remedy protectiveness. The remedy reduces the release of contaminants from subsurface soils by treating subsurface soils to meet protective cleanup levels.« less

  11. Applications of aerospace technology in industry, a technology transfer profile: Contamination control

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The strong influence NASA-sponsored research has had on the development of solutions to difficult contamination problems is considered. The contamination control field is comprised of an industrial base, supplying the tools of control; a user base, adopting control techniques; and a technical base, expanding the concepts of control. Both formal and informal mechanisms used by NASA to communicate a variety of technical advances are reviewed and certain examples of the expansion of the user base through technology transfer are given. Issues related to transfer of NASA-generated contamination control technology are emphasized.

  12. Trace Contaminant Control for the International Space Station's Node 1- Analysis, Design, and Verification

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Trace chemical contaminant generation inside crewed spacecraft cabins is a technical and medical problem that must be continuously evaluated. Although passive control through materials selection and active control by adsorption and catalytic oxidation devices is employed during normal operations of a spacecraft, contaminant buildup can still become a problem. Buildup is particularly troublesome during the stages between the final closure of a spacecraft during ground processing and the time that a crewmember enters for the first time during the mission. Typically, the elapsed time between preflight closure and first entry on orbit for spacecraft such as Spacelab modules was 30 days. During that time, the active contamination control systems are not activated and contaminants can potentially build up to levels which exceed the spacecraft maximum allowable concentrations (SMACs) specified by NASA toxicology experts. To prevent excessively high contamination levels at crew entry, the Spacelab active contamination control system was operated for 53 hours just before launch.

  13. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  14. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  15. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  16. 49 CFR 176.715 - Contamination control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Contamination control. 176.715 Section 176.715 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Requirements for Radioactive Materials § 176.715 Contamination control. Each hold, compartment, or deck area...

  17. Influence of blood contamination during multimode adhesive application on the microtensile bond strength to dentin.

    PubMed

    Kucukyilmaz, E; Celik, E U; Akcay, M; Yasa, B

    2017-12-01

    The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (μTBS) of multimode adhesives to dentin when using the self-etch approach. Seventy-five molars were randomly assigned to three adhesive groups comprising 25 specimens each: two multimode adhesives [Single Bond Universal (SBU) and All-Bond Universal (ABU)] and a conventional one-step self-etch adhesive [Clearfil S3 Bond Plus (CSBP)]. Each group was subdivided as follows: (1) uncontaminated (control): bonding application/light curing as a positive control; (2) contamination-1 (cont-1): bonding application/light curing/blood contamination/dry as a negative control; (3) contamination-2 (cont-2): bonding application/light curing/blood contamination/rinse/dry; (4) contamination-3 (cont-3): bonding application/blood contamination/dry/bonding re-application/light curing; and (5) contamination-4 (cont-4): bonding application/blood contamination/rinse/dry/bonding re-application/light curing. Dentin specimens were prepared for μTBS testing after the composite resin application. Data were analyzed with two-way ANOVA and post-hoc tests (α = 0.05). μTBS values were similar in cont-3 groups, and ABU/cont-4 and corresponding control groups, but were significantly lower in the other groups than in their control groups (P < 0.05). Cont-1 groups showed the lowest μTBS values (P < 0.05). Neither decontamination method prevented the decrease in μTBS when contamination occurred after light curing. Drying the blood contaminants and reapplying the adhesive may regain the dentin adhesion when contamination occurs before light curing. Alternatively, rinsing and drying contaminants followed by adhesive re-application may be effective depending on adhesive type.

  18. Radioactive Water Treatment at a United States Environmental Protection Agency Superfund Site - 12322

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beckman, John C.

    2012-07-01

    A water treatment system at a United States Environmental Protection Agency (USEPA) Superfund site impacted by radiological contaminants is used to treat water entering the site. The United States Army Corps of Engineers (USACE) is actively managing the remedial action for the USEPA using contracts to support the multiple activities on site. The site is where former gas mantle production facilities operated around the turn of the century. The manufacturing facilities used thorium ores to develop the mantles and disposed of off-specification mantles and ore residuals in the surrounding areas. During Site remedial actions, both groundwater and surface water comesmore » into contact with contaminated soils and must be collected and treated at an on-site treatment facility. The radionuclides thorium and radium with associated progeny are the main concern for treatment. Suspended solids, volatile organic compounds, and select metals are also monitored during water treatment. The water treatment process begins were water is pumped to a collection tank where debris and grit settle out. Stored water is pumped to a coagulant tank containing poly-aluminum chloride to collect dissolved solids. The water passes into a reaction tube where aspirated air is added or reagent added to remove Volatile Organic Compounds (VOC'S) by mass transfer and convert dissolved iron to a solid. The water enters the flocculent polymer tank to drop solids out. The flocculated water overflows to a fluidized bed contact chamber to increase precipitation. Flocculation is where colloids of material drop out of suspension and settle. The settled solids are periodically removed and disposed of as radioactive waste. The water is passed through filters and an ion exchange process to extract the radionuclides. Several million liters of water are processed each year from two water treatment plants servicing different areas of the remediation site. Ion exchange resin and filter material are periodically replaced and disposed of as radioactive waste. A total of 0.85 m{sup 3} of waste sludge per year requires disposal on average, in addition to another 6.6 m{sup 3} of waste cartridge filters. All water discharges are regulated by a state of New Jersey Pollutant Discharge Elimination System Permit implemented by the Federal Water Pollution Control Act (Clean Water Act). Laboratory analyses are required to satisfy requirements of the state NPDES permit. Specific monitoring parameters and discharge rates will be provided. Use of the water treatment systems drastically reduces the amount of contaminated water requiring solidification and water disposal to near zero. Millions of liters of potentially contaminated water from excavation activities is treated and released within permit limits. A small volume of solid radioactive waste (21 cubic meters) is generated annually from water treatment process operations. Management of ground and surface water is effectively controlled in remediation areas by the use of sumps, erosion control measures and pumping of water to storage vessels. Continued excavations can be made as water impacting the site is effectively controlled. (authors)« less

  19. Wound botulism acquired in the Amazonian rain forest of Ecuador.

    PubMed

    Reller, Megan E; Douce, Richard W; Maslanka, Susan E; Torres, Darwin S; Manock, Stephen R; Sobel, Jeremy

    2006-04-01

    Wound botulism results from colonization of a contaminated wound by Clostridium botulinum and the anaerobic in situ production of a potent neurotoxin. Between 1943, when wound botulism was first recognized, and 1990, 47 laboratory-confirmed cases, mostly trauma-associated, were reported in the United States. Since 1990, wound botulism associated with injection drug use emerged as the leading cause of wound botulism in the United States; 210 of 217 cases reported to the Centers for Disease Control and Prevention between 1990 and 2002 were associated with drug injection. Despite the worldwide distribution of Clostridium botulinum spores, wound botulism has been reported only twice outside the United States, Europe, and Australia. However, wound botulism may go undiagnosed and untreated in many countries. We report two cases, both with type A toxin, from the Ecuadorian rain forest. Prompt clinical recognition, supportive care, and administration of trivalent equine botulinum antitoxin were life-saving.

  20. Supporting evaluation for the proposed plan for final remedial action for the groundwater operable unit at the chemical plant area of the Weldon Spring Site, Weldon Spring, Missouri.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2003-08-06

    This report presents the technical information developed since the interim record of decision (IROD) was issued in September 2000 (U.S. Department of Energy [DOE] 2000). The information was incorporated into the evaluation that was performed in selecting the preferred alternative for the Chemical Plant groundwater operable unit (GWOU) of the Weldon Spring site. The contaminants of concern (COCs) in groundwater and springs are trichloroethylene (TCE), nitrate, uranium, and nitroaromatic compounds. The preferred alternative of monitored natural attenuation (MNA) coupled with institutional controls (ICs) and contingency activities is described in the ''Proposed Plan (PP) for Final Remedial Action for the Groundwatermore » Operable Unit at the Chemical Plant Area of the Weldon Spring Site, Weldon Spring, Missouri'' (DOE 2003b).« less

  1. Corrective Action Investigation Plan for Corrective Action Unit 204: Storage Bunkers, Nevada Test Site, Nevada (December 2002, Revision No.: 0), Including Record of Technical Change No. 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NNSA /NSO

    The Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 204 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 204 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of six Corrective Action Sites (CASs) which include: 01-34-01, Underground Instrument House Bunker; 02-34-01, Instrument Bunker; 03-34-01, Underground Bunker; 05-18-02, Chemical Explosives Storage; 05-33-01, Kay Blockhouse; 05-99-02, Explosive Storage Bunker.more » Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for Corrective Action Unit 204 collectively include radionuclides, beryllium, high explosives, lead, polychlorinated biphenyls, total petroleum hydrocarbons, silver, warfarin, and zinc phosphide. The primary question for the investigation is: ''Are existing data sufficient to evaluate appropriate corrective actions?'' To address this question, resolution of two decision statements is required. Decision I is to ''Define the nature of contamination'' by identifying any contamination above preliminary action levels (PALs); Decision II is to ''Determine the extent of contamination identified above PALs. If PALs are not exceeded, the investigation is completed. If PALs are exceeded, then Decision II must be resolved. In addition, data will be obtained to support waste management decisions. Field activities will include radiological land area surveys, geophysical surveys to identify any subsurface metallic and nonmetallic debris, field screening for applicable contaminants of potential concern, collection and analysis of surface and subsurface soil samples from biased locations, and step-out sampling to define the extent of contamination, as necessary. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document.« less

  2. Accidental introductions are an important source of invasive plants in the continental United States.

    PubMed

    Lehan, Nora E; Murphy, Julia R; Thorburn, Lukas P; Bradley, Bethany A

    2013-07-01

    Preventing new plant invasions is critical for reducing large-scale ecological change. Most studies have focused on the deliberate introduction of nonnatives via the ornamental plant trade. However, accidental introduction may be an important source of nonnative, invasive plants. Using Web and literature searches, we compiled pathways of introduction to the United States for 1112 nonnative plants identified as invasive in the continental United States. We assessed how the proportion of accidentally and deliberately introduced invasive plants varies over time and space and by growth habit across the lower 48 states. Deliberate introductions of ornamentals are the primary source of invasive plants in the United States, but accidental introductions through seed contaminants are an important secondary source. Invasive forbs and grasses are the most likely to have arrived accidentally through seed contaminants, while almost all nonnative, invasive trees were introduced deliberately. Nonnative plants invading eastern states primarily arrived deliberately as ornamentals, while a high proportion of invasive plants in western states arrived accidentally as seed contaminants. Accidental introductions may be increasing in importance through time. Before 1850, 10 of 89 (11%) of invasive plants arrived accidentally. After 1900, 20 of 65 (31%) arrived accidentally. Recently enacted screening protocols and weed risk assessments aim to reduce the number of potentially invasive species arriving to the United States via deliberate introduction pathways. Increasing proportions of accidentally introduced invasive plants, particularly associated with contaminated seed imports across the western states, suggest that accidental introduction pathways also need to be considered in future regulatory decisions.

  3. Ground water contamination by crude oil near Bemidji, Minnesota

    USGS Publications Warehouse

    Delin, G.N.; Essaid, H.I.; Cozzarelli, I.M.; Lahvis, M.H.; Bekins, B.A.

    1998-01-01

    Ground-water contamination by crude oil, and other petroleum-based liquids, is a widespread problem. An average of 83 crude-oil spills occurred per year during 1994-96 in the United States, each spilling about 50,000 barrels of crude oil (U.S. Office of Pipeline Safety, electronic commun., 1997). An understanding of the fate of organic contaminants (such as oil and gasoline) in the subsurface is needed to design innovative and cost-effective remedial solutions at contaminated sites.

  4. Endotoxin contamination and control in surface water sources and a drinking water treatment plant in Beijing, China.

    PubMed

    Can, Zhang; Wenjun, Liu; Wen, Sun; Minglu, Zhang; Lingjia, Qian; Cuiping, Li; Fang, Tian

    2013-07-01

    In this paper, endotoxin contamination was determined in treated water following each unit of a drinking water treatment plant (WTP) in Beijing, China and its source water (SW) from a long water diversion channel (Shijiazhuang-Beijing) originating from four reservoirs in Hebei province, China. The total-endotoxin activities in SW ranged from 21 to 41 EU/ml at five selected cross sections of the diversion channel. The total-endotoxin in raw water of the WTP ranged from 11 to 16 EU/ml due to dilution and pretreatment during water transportation from Tuancheng Lake to the WTP, and finished water of the WTP ranged from 4 to 10 EU/ml, showing a 49% decrease following the full-scale treatment process at the WTP. Compared with the 31% removal of free-endotoxin, the WTP removed up to 71% of bound-endotoxin in raw water. The traditional treatment processes (coagulation, sedimentation and filtration) in the WTP removed substantial amounts of total-endotoxin (up to 63%), while endotoxin activities increased after granular activated carbon (GAC) adsorption and chlorination. The total-endotoxin in the actual water was composed of free-endotoxin and bound-endotoxin (endotoxin aggregates, bacteria-bound endotoxins and particle-attached endotoxins). The endotoxin aggregates, bacteria-bound endotoxins and particle-attached endotoxins co-exist as suspended particles in water, and only the bacteria-bound endotoxins were correlated with bacterial cells suspended in water. The particle distribution of endotoxin aggregates in ultrapure water was also tested and the results showed that the majority (64-89%) of endotoxin aggregates had diameters <2 μm. The endotoxin contamination and control in treated water following each unit of the WTP processes and its SW from reservoirs are discussed and compared with regard to bacterial cell counts and particle characteristics, which were dependent, to a certain extent, on different flow rates and turbulence of the water environments. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. PERCHLORATE IDENTIFICATION IN FERTILIZERS

    EPA Science Inventory

    Perchlorate has contaminated groundwater, drinking water, and soils at several locations in the United States. The primary source of contamination at sites that have been investigated to date seems to be from industrial and military operations that use perchlorate as an oxidizing...

  6. SOIL WASHING TREATABILITY TESTS FOR PESTICIDE- CONTAMINATED SOIL

    EPA Science Inventory

    The 1987 Sand Creek Operable Unit 5 record of decision (ROD) identified soil washing as the selected technology to remediate soils contaminated with high levels of organochlorine pesticides, herbicides, and metals. Initial treatability tests conducted to assess the applicability...

  7. EVALUATING EXCESS DIETARY EXPOSURE OF YOUNG CHILDREN EATING IN CONTAMINATED ENVIRONMENTS

    EPA Science Inventory

    The United States' Food Quality Protection Act of 1996 requires more accurate assessment of children's aggregate exposures to environmental contaminants. Since children have unstructured eating behaviors, their excess exposures, caused by eating activities, becomes an importan...

  8. Microbiological contamination of mobile phones of clinicians in intensive care units and neonatal care units in public hospitals in Kuwait.

    PubMed

    Heyba, Mohammed; Ismaiel, Mohammad; Alotaibi, Abdulrahman; Mahmoud, Mohamed; Baqer, Hussain; Safar, Ali; Al-Sweih, Noura; Al-Taiar, Abdullah

    2015-10-15

    The objective of this study was to explore the prevalence of microbiological contamination of mobile phones that belong to clinicians in intensive care units (ICUs), pediatric intensive care units (PICUs), and neonatal care units (NCUs) in all public secondary care hospitals in Kuwait. The study also aimed to describe mobile phones disinfection practices as well as factors associated with mobile phone contamination. This is a cross-sectional study that included all clinicians with mobile phones in ICUs, PICUs, and NCUs in all secondary care hospitals in Kuwait. Samples for culture were collected from mobile phones and transported for microbiological identification using standard laboratory methods. Self-administered questionnaire was used to gather data on mobile phones disinfection practices. Out of 213 mobile phones, 157 (73.7 %, 95 % CI [67.2-79.5 %]) were colonized. Coagulase-negative staphylococci followed by Micrococcus were predominantly isolated from the mobile phones; 62.9 % and 28.6 % of all mobile phones, respectively. Methicillin-resistant Staphylococcus aureus (MRSA) and Gram-negative bacteria were identified in 1.4 % and 7.0 % of the mobile phones, respectively. Sixty-eight clinicians (33.5 %) reported that they disinfected their mobile phones, with the majority disinfecting their mobile phones only when they get dirty. The only factor that was significantly associated with mobile phone contamination was whether a clinician has ever disinfected his/her mobile phone; adjusted odds ratio 2.42 (95 % CI [1.08-5.41], p-value = 0.031). The prevalence of mobile phone contamination is high in ICUs, PICUs, and NCUs in public secondary care hospitals in Kuwait. Although some of the isolated organisms can be considered non-pathogenic, various reports described their potential harm particularly among patients in ICU and NCU settings. Isolation of MRSA and Gram-negative bacteria from mobile phones of clinicians treating patients in high-risk healthcare settings is of a major concern, and calls for efforts to consider guidelines for mobile phone disinfection.

  9. Process Upsets Involving Trace Contaminant Control Systems

    NASA Technical Reports Server (NTRS)

    Graf, John C.; Perry, Jay; Wright, John; Bahr, Jim

    2000-01-01

    Paradoxically, trace contaminant control systems that suffer unexpected upsets and malfunctions can release hazardous gaseous contaminants into a spacecraft cabin atmosphere causing potentially serious toxicological problems. Trace contaminant control systems designed for spaceflight typically employ a combination of adsorption beds and catalytic oxidation reactors to remove organic and inorganic trace contaminants from the cabin atmosphere. Interestingly, the same design features and attributes which make these systems so effective for purifying a spacecraft's atmosphere can also make them susceptible to system upsets. Cabin conditions can be contributing causes of phenomena such as adsorbent "rollover" and catalyst poisoning can alter a systems performance and in some in stances release contamination into the cabin. Evidence of these phenomena has been observed both in flight and during ground-based tests. The following discussion describes specific instances of system upsets found in trace contaminant control systems, groups these specific upsets into general hazard classifications, and recommends ways to minimize these hazards.

  10. 10 CFR 835.1102 - Control of areas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Radioactive Contamination Control § 835.1102 Control... transfer of removable contamination to locations outside of radiological areas under normal operating conditions. (b) Any area in which contamination levels exceed the values specified in appendix D of this part...

  11. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  12. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  13. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  14. 49 CFR 173.443 - Contamination control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Contamination control. 173.443 Section 173.443 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.443 Contamination control. (a) The level of...

  15. Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Jennings, Mallory A.; Paul, Heather L.; Waguespack, Glenn M.

    2010-01-01

    This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

  16. A Design Basis for Spacecraft Cabin Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.

    2009-01-01

    Successful trace chemical contamination control is one of the components necessary for achieving good cabin atmospheric quality. While employing seemingly simple process technologies, sizing the active contamination control equipment must employ a reliable design basis for the trace chemical load in the cabin atmosphere. A simplified design basis that draws on experience gained from the International Space Station program is presented. The trace chemical contamination control design load refines generation source magnitudes and includes key chemical functional groups representing both engineering and toxicology challenges.

  17. Trace Contaminant Control During the International Space Station's On-Orbit Assembly and Outfitting

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2017-01-01

    Achieving acceptable cabin air quality must balance competing elements during spacecraft design, assembly, ground processing, and flight operations. Among the elements that contribute to the trace chemical contaminant load and, therefore, the cabin air quality aboard crewed spacecraft are the vehicle configuration, crew size and activities, mission duration and objectives, materials selection, and vehicle manufacturing and preflight ground processing methods. Trace chemical contaminants produced from pervasive sources such as equipment offgassing, human metabolism, and cleaning fluids during preflight ground processing present challenges to maintaining acceptable cabin air quality. To address these challenges, both passive and active contamination control techniques are used during a spacecraft's design, manufacturing, preflight preparation, and operational phases. Passive contamination control methods seek to minimize the equipment offgassing load by selecting materials, manufacturing processes, preflight preparation processes, and in-flight operations that have low chemical offgassing characteristics. Passive methods can be employed across the spacecraft's entire life cycle from conceptual design through flight operations. However, because the passive contamination control techniques cannot fully eliminate the contaminant load, active contamination control equipment must be deployed aboard the spacecraft to purify and revitalize the cabin atmosphere during in-flight operations. Verifying that the passive contamination control techniques have successfully maintained the total trace contaminant load within the active contamination control equipment's capabilities occurs late in the preflight preparation stages. This verification consists of subjecting the spacecraft to an offgassing test to determine the trace contaminant load. This load is then assessed versus the active contamination control equipment's capabilities via trace contaminant control (TCC) engineering analysis. During the International Space Station's (ISS's) on-orbit assembly and outfitting, a series of engineering analyses were conducted to evaluate how effective the passive TCC methods were relative to providing adequate operational margin for the active TCC equipment's capabilities aboard the ISS. These analyses were based on habitable module and cargo vehicle offgassing test results. The offgassing test for a fully assembled module or cargo vehicle is an important preflight spacecraft evaluation method that has been used successfully during all crewed spacecraft programs to provide insight into how effectively the passive contamination control methods limit the equipment offgassing component of the overall trace contaminant generation load. The progression of TCC assessments beginning in 1998 with the ISS's first habitable element launch and continuing through the final pressurized element's arrival in 2010 are presented. Early cargo vehicle flight assessments between 2008 and 2011 are also presented as well as a discussion on predictive methods for assessing cargo via a purely analytical technique. The technical approach for TCC employed during this 13-year period successfully maintained the cabin atmospheric quality within specified parameters during the technically challenging ISS assembly and outfitting stages. The following narrative provides details on the important role of spacecraft offgassing testing, trace contaminant performance requirements, and flight rules for achieving the ultimate result-a cabin environment that enables people to live and work safely in space.

  18. Diazinon reduction and partitioning between water, sediment and vegetation in stormwater runoff mitigation through rice fields.

    PubMed

    Moore, Matthew T; Kröger, Robert; Cooper, Charles M; Cullum, Robert F; Smith, Sammie; Locke, Martin A

    2009-11-01

    Contamination of surface waters by pesticides is a concern in the United States and around the world. Innovative mitigation strategies are needed to remediate this potential environmental contaminant. One potential solution is to divert pesticide-laden drainage or surface water through agricultural rice fields. With a hydroperiod, hydrosoil and hydrophyte (rice), these systems serve essentially as a type of constructed wetland. In both summer and fall experiments, diazinon-amended water was diverted through two rice ponds at the University of Mississippi Field Station. Likewise, a non-vegetated control pond was amended with diazinon-laden water. Water, sediment and plant samples were taken spatially and temporally to determine the distribution of diazinon within systems. Outflow diazinon concentrations decreased significantly (P < 0.05) from inflow in both vegetated ponds for both preharvest and post-harvest experiments. Although sorption to rice plants was minimal in the overall mass distribution of diazinon (1-3%), temporal data indicated that diazinon concentrations reached the outflow sediment of the non-vegetated control twice as fast as in either vegetated (rice) system. In both vegetated systems, sediment diazinon concentrations decreased (77 and 100%) from inflow to outflow, while a decrease of <2% was noted in the non-vegetated control. Diversion of pesticide-contaminated water through rice fields demonstrated potential as a low-cost, environmentally efficient mitigation practice. Studies on these systems are continuing to evaluate the optimal chemical retention time for rice field mitigation, as well as diazinon transfer to rice grain seeds that may be used as a food source.

  19. Payload/orbiter contamination control requirement study: Preliminary contamination mission support plan. [a management analysis of project planning of spacecraft sterilization

    NASA Technical Reports Server (NTRS)

    Bareiss, L. E.; Hooper, V. W.; Ress, E. B.

    1976-01-01

    Progress is reported on the mission support plan and those support activities envisioned to be applicable and necessary during premission and postmission phases of the Spacelab program. The purpose, role, and requirements of the contamination control operations for the first two missions of the Spacelab equipped Space Transportation System are discussed. The organization of the contamination control operation and its relationship to and interfaces with other mission support functions is also discussed. Some specific areas of contamination to be investigated are treated. They are: (1) windows and viewports, (2) experiment equipment, (3) thermal control surfaces, (4) the contaminant induced atmosphere (as differentiated from the normal ambient atmosphere at the orbit altitude), and (5) optical navigation instruments.

  20. Results of the Trace Contaminant Control Needs Evaluation and Sizing Study for Space Suit Life Support Development

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.; Jennings, Mallory A.

    2009-01-01

    The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for CSSE pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

  1. Panel summary of recommendations

    NASA Technical Reports Server (NTRS)

    Dunbar, Bonnie J.; Coleman, Martin E.; Mitchell, Kenneth L.

    1990-01-01

    The following Space Station internal contamination topics were addressed: past flight experience (Skylab and Spacelab missions); present flight activities (Spacelabs and Soviet Space Station Mir); future activities (materials science and life science experiments); Space Station capabilities (PPMS, FMS, ECLSS, and U.S. Laboratory overview); manned systems/crew safety; internal contamination detection; contamination control - stowage and handling; and contamination control - waste gas processing. Space Station design assumptions are discussed. Issues and concerns are discussed as they relate to (1) policy and management, (2) subsystem design, (3) experiment design, and (4) internal contamination detection and control. The recommendations generated are summarized.

  2. The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Kayatin, Matthew J.

    2016-01-01

    Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.

  3. Effect of mobile laminar airflow units on airborne bacterial contamination during neurosurgical procedures.

    PubMed

    von Vogelsang, A-C; Förander, P; Arvidsson, M; Löwenhielm, P

    2018-03-24

    Surgical site infections (SSIs) after neurosurgery are potentially life-threatening and entail great costs. SSIs may occur from airborne bacteria in the operating room, and ultraclean air is desired during infection-prone cleaning procedures. Door openings and the number of persons present in the operating room affect the air quality. Mobile laminar airflow (MLAF) units, with horizontal laminar airflow, have previously been shown to reduce airborne bacterial contamination. To assess the effect of MLAF units on airborne bacterial contamination during neurosurgical procedures. In a quasi-experimental design, bacteria-carrying particles (colony-forming units: cfu) during neurosurgical procedures were measured with active air-sampling in operating rooms with conventional turbulent ventilation, and with additional MLAF units. The MLAF units were shifted between operating rooms monthly. Colony-forming unit count and bacterial species detection were conducted after incubation. Data was collected for a period of 18 months. A total of 233 samples were collected during 45 neurosurgical procedures. The use of MLAF units significantly reduced the numbers of cfu in the surgical site area (P < 0.001) and above the instrument table (P < 0.001). Logistic regression showed that the only significant predictor affecting cfu count was the use of MLAF units (odds ratio: 41.6; 95% confidence interval: 11.3-152.8; P < 0.001). The most frequently detected bacteria were coagulase-negative staphylococci. MLAF successfully reduces cfu during neurosurgery to ultraclean air levels. MLAF units are valuable when the main operating room ventilation system is unable to produce ultraclean air in infection-prone clean neurosurgery. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

    NASA Technical Reports Server (NTRS)

    Kayatin, Matthew J.; Perry, Jay L.

    2017-01-01

    Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

  5. 2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.

    PubMed

    Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole

    2006-02-15

    The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass spectrophotometry (GC/MS). Several important conclusions can be drawn from this study including (1) surface waters were confirmed to be more vulnerable to atrazine contamination than groundwater sources, (2) peak atrazine concentrations corresponded well to precipitation/runoff events, and (3) atrazine occurrence tended to be uniform geographically when compared by river drainage basins. In addition, this project confirmed that the Abraxis atrazine ELISA test kit tended to have a positive bias (i.e., the measured ELISA concentration was higher than the actual concentration) in most measured samples. Finished samples tended to have more of a positive bias than raw water samples. Therefore, this bias may limit the effectiveness for ELISA for regulatory monitoring. There are many other applications for ELISA, however, including frequent monitoring for early detections of atrazine concentration changes that might trigger conventional analysis by GC/MS or be used for activated carbon dosing or other treatment operating controls.

  6. In Vitro Microbiology Studies on a New Peritoneal Dialysis Connector

    PubMed Central

    Di Bonaventura, Giovanni; Cerasoli, Paolo; Pompilio, Arianna; Arrizza, Fabio; Di Liberato, Lorenzo; Stingone, Antonio; Sirolli, Vittorio; Arduini, Arduino; Bonomini, Mario

    2012-01-01

    ♦ Objective: We evaluated the ability of a recently developed peritoneal dialysis (PD) connector to prevent the risk of bacterial transfer to the fluid path after simulated touch and airborne contamination. ♦ Methods: Staphylococcus epidermidis ATCC1228 and Pseudomonas aeruginosa ATCC27853 strains were used. For touch contamination, 2 μL of a standardized inoculum [1×108 colony-forming units (CFU) per milliliter] were deposited on top of the pin closing the fluid path of the patient connector. For airborne contamination, the patient connector was exposed for 15 seconds to a nebulized standardized inoculum. To simulate the patient peritoneum and effluent, the patient connector was pre-attached to a 2-L bag of sterile PD solution. After contamination, the patient connector was attached to the transfer set, the pin was captured, flow control was turned to simulate “patient drain” into the empty bag, and then “patient fill” using the bag pre-attached to the connector. Finally, a new pin was recaptured. The PD solution collected in the bag pre-attached to the connector was run through a 0.20-μm filter for colony counts. ♦ Results: No infected connector transferred bacteria to the fluid path, regardless of the challenge procedure or the strain used. ♦ Conclusions: Our results show that the new PD connector may fully obviate the risk of bacterial infection, even in the presence of heavy contamination. Further studies are in progress to test our PD connector in a clinical setting. PMID:22302771

  7. Survival of Staphylococcus pseudintermedius in modified Romanowsky staining solutions.

    PubMed

    Misan, Angus; Chan, Wei Yee; Trott, Darren; Hill, Peter B

    2017-08-01

    Stains that are used regularly for patient-side diagnosis to rapidly identify bacterial and fungal infections could become contaminated by common pathogens, such as Staphylococcus pseudintermedius, during slide immersion. To determine whether the inoculation of S. pseudintermedius into modified Romanowsky type stains (Quick Dip ® ) results in viable bacterial contamination and whether this is influenced by the addition of organic debris (canine hair and skin). A clinical isolate of S. pseudintermedius was inoculated into clean and organically contaminated Quick Dip ® solutions (methanol fixative, eosin, methylene blue), and positive (broth) and negative (bleach) controls. Each solution was tested for the presence of viable bacteria by counting the number of colony forming units (CFU/mL) at various time points. Solutions also were examined under high power microscopy to count the number of visible bacteria at each time point. Staphylococcus pseudintermedius was able to survive in the clean and contaminated Quick Dip ® stains for at least one hour, but by 24 h no viable bacteria remained. Survival of the bacteria was not supported in the fixative at any time point. Staphylococcus pseudintermedius remained visible under high power microscopy for up to 2 weeks in all organically contaminated solutions of the Quick Dip ® set. Staphylococcus pseudintermedius only remains viable in eosin and methylene blue for short periods of time, but the prolonged visibility of dead organisms could theoretically lead to the misdiagnosis of cytology samples. © 2017 ESVD and ACVD.

  8. PERCHLORATE CROP INTERACTIONS VIA CONTAMINATED IRRIGATION WATER

    EPA Science Inventory

    Perchlorate has contaminated water and sods at several locations in the United States. Perchlorate is water soluble, exceedingly mobile in aqueous systems, and can persist for many decades under typical ground- and surface water conditions. Perchlorate is of concern because of un...

  9. EVALUATION OF A GENERIC ARRAY APPROACH FOR GENOTYPING NOROVIRUSES

    EPA Science Inventory

    Noroviruses are the leading cause of nonbacterial gastroenteritis outbreaks in the United States. Because of their potential to contaminate drinking water, the U.S Environmental Protection Agency has included noroviruses on the Contaminant Candidate List (CCL) to assess the publi...

  10. PERCHLORATE ACCUMULATION FROM FERTILIZER IN LEAFY VEGETATION

    EPA Science Inventory

    Perchlorate contaminated water and soil has been identified in many areas of the United States. Previous studies indicated that the primary source of contamination was from industry and military operations that use perchlorate as an oxidzing agent. However, recent studies have fo...

  11. Evaluating Infection Prevention Strategies in Out-Patient Dialysis Units Using Agent-Based Modeling.

    PubMed

    Wares, Joanna R; Lawson, Barry; Shemin, Douglas; D'Agata, Erika M C

    2016-01-01

    Patients receiving chronic hemodialysis (CHD) are among the most vulnerable to infections caused by multidrug-resistant organisms (MDRO), which are associated with high rates of morbidity and mortality. Current guidelines to reduce transmission of MDRO in the out-patient dialysis unit are targeted at patients considered to be high-risk for transmitting these organisms: those with infected skin wounds not contained by a dressing, or those with fecal incontinence or uncontrolled diarrhea. Here, we hypothesize that targeting patients receiving antimicrobial treatment would more effectively reduce transmission and acquisition of MDRO. We also hypothesize that environmental contamination plays a role in the dissemination of MDRO in the dialysis unit. To address our hypotheses, we built an agent-based model to simulate different treatment strategies in a dialysis unit. Our results suggest that reducing antimicrobial treatment, either by reducing the number of patients receiving treatment or by reducing the duration of the treatment, markedly reduces overall colonization rates and also the levels of environmental contamination in the dialysis unit. Our results also suggest that improving the environmental decontamination efficacy between patient dialysis treatments is an effective method for reducing colonization and contamination rates. These findings have important implications for the development and implementation of future infection prevention strategies.

  12. Spread of Pseudomonas fluorescens due to contaminated drinking water in a bone marrow transplant unit.

    PubMed

    Wong, Vanessa; Levi, Katrina; Baddal, Buket; Turton, Jane; Boswell, Tim C

    2011-06-01

    Pseudomonas infections are an important cause of morbidity and mortality in immunocompromised patients. We present here data for the spread of Pseudomonas fluorescens caused by a contaminated drinking water dispenser in a bone marrow transplant unit. Over a 1-month period we observed a sharp increase in the isolation of P. fluorescens from weekly pharyngeal surveillance swabs. Environmental samples were taken from a variety of water sources throughout the unit. These samples were cultured on cetrimide agar medium, and isolates were epidemiologically characterized by antibiotic susceptibility patterns and molecular typing methods. Nine patients became colonized with P. fluorescens, and six out of the nine developed febrile neutropenia. P. fluorescens was cultured after the filtration of 100 ml of drinking water from one of two stand-alone chiller units supplying cooled bottled water to the bone marrow transplant unit. All other environmental samples were negative. There were no further cases of P. fluorescens colonization after the contaminated dispenser was removed. Molecular typing showed that all P. fluorescens isolates were identical by both random amplification of polymorphic DNA PCR and pulsed-field gel electrophoresis. We recommend that such bottled water supplies not be used in high-risk areas or be subject to regular microbiological monitoring.

  13. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2015 and FY2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A; Miller, Julianne J; McCurdy, Greg

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff. This activity supports Nevada Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closuremore » design and post-closure monitoring program.« less

  14. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2013 and FY2014 (revised)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A.; Miller, Julianne J.; McCurdy, Greg D.

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff, which supports National Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closure designmore » and post-closure monitoring program.« less

  15. Bio-Contamination Control for Spacesuit Garments - A Preliminary Study

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Korona, Adam; Orndoff, Evelyn; Ott, Mark; Poritz, Darwin

    2010-01-01

    This paper outlines a preliminary study to review, test, and improve upon the current state of spacesuit bio-contamination control. The study includes an evaluation of current and advanced suit materials, ground and on-orbit cleaning methods, and microbial test and analysis methods. The first aspect of this study was to identify potential anti-microbial textiles and cleaning agents, and to review current microbial test methods. The anti-microbial cleaning agent and textile market survey included a review of current commercial-off-the-shelf (COTS) products that could potentially be used as future space flight hardware. This review included replacements for any of the softgood layers that may become contaminated during an extravehicular activity (EVA), including the pressure bladder, liquid cooling garment, and ancillary comfort undergarment. After a series of COTS anti-microbial textiles and clean ing agents were identified, a series of four tests were conducted: (1) a stacked configuration test that was conducted in order to review how bio-contamination would propagate through the various suit layers, (2) a individual materials test that evaluated how well each softgood layer either promoted or repressed growth, (3) a cleaning agent test that evaluated the efficacy on each of the baseline bladders, and (4) an evaluation of various COTS anti-microbial textiles. All antimicrobial COTS materials tested appeared to control bacteria colony forming unit (CFU) growth better than the Thermal Comfort Undergarment (TCU) and ACES Liquid Cooling Garment (LCG)/EMU Liquid Cooling Ventilation Garment (LCVG) materials currently in use. However, a comparison of fungi CFU growth in COTS to current suit materials appeared to vary per material. All cleaning agents tested in this study appeared to inhibit the level of bacteria and fungi growth to acceptable levels for short duration tests. While several trends can be obtained from the current analysis, a series of test improvements are described for future microbial testing.

  16. An evaluation of the toxicity of contaminated sediments from Waukegan Harbor, Illinois, following remediation

    USGS Publications Warehouse

    Kemble, N.E.; Hardesty, D.G.; Ingersoll, C.G.; Johnson, B. Thomas; Dwyer, F.J.; MacDonald, D.D.

    2000-01-01

    Waukegan Harbor in Illinois was designated as a Great Lakes Area of Concern due to high concentrations of sediment-associated polychlorinated biphenyls (PCBs). The objective of this study was to evaluate the toxicity of 20 sediment samples collected after remediation (primarily dredging) of Waukegan Harbor for PCBs. A 42-day whole sediment toxicity test with the amphipod Hyalella azteca (28-day sediment exposure followed by a 14-day reproductive phase) and sediment toxicity tests with Microtox® were conducted to evaluate sediments from Waukegan Harbor. Endpoints measured were survival, growth, and reproduction (amphipods) and luminescent light emission (bacteria). Survival of amphipods was significantly reduced in 6 of the 20 sediment samples relative to the control. Growth of amphipods (either length or weight) was significantly reduced relative to the control in all samples. However, reproduction of amphipods identified only two samples as toxic relative to the control. The Microtox basic test, conducted with organic extracts of sediments identified only one site as toxic. In contrast, the Microtox solid-phase test identified about 50% of the samples as toxic. A significant negative correlation was observed between reproduction and the concentration of three polynuclear aromatic hydrocarbons (PAHs) normalized to total organic carbon. Sediment chemistry and toxicity data were evaluated using sediment quality guidelines (consensus-based probable effect concentrations, PECs). Results of these analyses indicate that sediment samples from Waukegan Harbor were toxic to H. azteca contaminated at similar contaminant concentrations as sediment samples that were toxic to H. azteca from other areas of the United States. The relationship between PECs and the observed toxicity was not as strong for the Microtox test. The results of this study indicate that the first phase of sediment remediation in Waukegan Harbor successfully lowered concentrations of PCBs at the site. Though the sediments were generally not lethal, there were still sublethal effects of contaminants in sediments at this site observed on amphipods in long-term exposures (associated with elevated concentrations of metals, PCBs, and PAHs).

  17. Prevention of EP Migratory Contamination in a Cluster Randomized Trial to Increase tPA Use in Stroke (The INSTINCT Trial)

    PubMed Central

    Weston, Victoria C.; Meurer, William J.; Frederiksen, Shirley M.; Fox, Allison K.; Scott, Phillip A.

    2016-01-01

    Objectives Cluster randomized trials (CRTs) are increasingly utilized to evaluate quality improvement interventions aimed at healthcare providers. In trials testing emergency department interventions, migration of emergency physicians (EPs) between hospitals is an important concern, as contamination may affect both internal and external validity. We hypothesized that geographically isolating emergency departments would prevent migratory contamination in a CRT designed to increase ED delivery of tPA in stroke (The INSTINCT Trial). Methods INSTINCT was a prospective, cluster randomized, controlled trial. 24 Michigan community hospitals were randomly selected in matched pairs for study. Contamination was defined at the cluster level, with substantial contamination defined a priori as >10% of EPs affected. Non-adherence, total crossover (contamination + non-adherence), migration distance and characteristics were determined. Results 307 emergency physicians were identified at all sites. Overall, 7 (2.3%) changed study sites. 1 moved between control sites, leaving 6 (2.0%) total crossovers. Of these, 2 (0.7%) moved from intervention to control (contamination) and 4 (1.3%) moved from control to intervention (non-adherence). Contamination was observed in 2 of 12 control sites, with 17% and 9% contamination of the total site EP workforce at follow-up, respectively. Average migration distance was 42 miles for all EPs moving in the study and 35 miles for EPs moving from intervention to control sites. Conclusion The mobile nature of emergency physicians should be considered in the design of quality improvement CRTs. Increased reporting of contamination in CRTs is encouraged to clarify thresholds and facilitate CRT design. PMID:25440230

  18. Osprey: worldwide sentinel species for assessing and monitoring environmental contamination in rivers, lakes, reservoirs, and estuaries.

    PubMed

    Grove, Robert A; Henny, Charles J; Kaiser, James L

    2009-01-01

    In the United States, many fish and wildlife species have been used nationwide to monitor environmental contaminant exposure and effects, including carcasses of the bald eagle (Haliaeetus leucocephalus), the only top avian predator regularly used in the past. Unfortunately, bald eagles are sensitive to investigator intrusion at the nest. Thus, the osprey (Pandion haliaetus) is evaluated as a potential sentinel species for aquatic ecosystems. Several characteristics support the choice of the osprey as a sentinel species, including: (1) fish-eating diet atop the aquatic food web, (2) long-lived with strong nest fidelity, (3) adapts to human landscapes (potentially the most contaminated), (4) tolerates short-term nest disturbance, (5) nests spatially distributed at regular intervals, (6) highly visible nests easily located for study, (7) ability to accumulate most, if not all, lipophilic contaminants, (8) known sensitivity to many contaminants, and (9) nearly a worldwide distribution. These osprey traits have been instrumental in successfully using the species to understand population distribution, abundance, and changes over time; the effects of various contaminants on reproductive success; how contaminants in prey (fish on biomass basis) contribute to egg concentrations (i.e., biomagnification factors); and spatial residue patterns. Data summarized include nesting population surveys, detailed nesting studies, and chemical analyses of osprey egg, organ, blood, and feather samples for contaminants that bioaccumulate and/or biomagnify in aquatic food webs; and biochemical evaluations of blood and various organs. Studies in the United States, Canada, Mexico, Europe, and elsewhere have shown the osprey to be a useful sentinel species for monitoring selected environmental contaminants, including some emerging contaminants in lakes, reservoirs, rivers, and estuaries.

  19. Assessing Inhalation Exposures Associated with Contamination Events in Water Distribution Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Michael J.; Janke, Robert; Taxon, Thomas N.

    When a water distribution system (WDS) is contaminated, short-term inhalation exposures to airborne contaminants could occur as the result of domestic water use. The most important domestic sources of such exposures are likely to be showering and the use of aerosol-producing humidifiers, i.e., ultrasonic and impeller (cool-mist) units. A framework is presented for assessing the potential effects of short-term, system-wide inhalation exposures that could result from such activities during a contamination event. This framework utilizes available statistical models for showering frequency and duration, available exposure models for showering and humidifier use, and experimental results on both aerosol generation and themore » volatilization of chemicals during showering. New models for the times when showering occurs are developed using time-use data for the United States. Given a lack of similar models for how humidifiers are used, or the information needed to develop them, an analysis of the sensitivity of results to assumptions concerning humidifier use is presented. The framework is applied using network models for three actual WDSs. Simple models are developed for estimating upper bounds on the potential effects of system-wide inhalation exposures associated with showering and humidifier use. From a system-wide, population perspective, showering could result in significant inhalation doses of volatile chemical contaminants, and humidifier use could result in significant inhalation doses of microbial contaminants during a contamination event. From a system-wide perspective, showering is unlikely to be associated with significant doses of microbial contaminants. In conclusion, given the potential importance of humidifiers as a source of airborne contaminants during a contamination event, an improved understanding of the nature of humidifier use is warranted.« less

  20. Assessing Inhalation Exposures Associated with Contamination Events in Water Distribution Systems

    DOE PAGES

    Davis, Michael J.; Janke, Robert; Taxon, Thomas N.

    2016-12-08

    When a water distribution system (WDS) is contaminated, short-term inhalation exposures to airborne contaminants could occur as the result of domestic water use. The most important domestic sources of such exposures are likely to be showering and the use of aerosol-producing humidifiers, i.e., ultrasonic and impeller (cool-mist) units. A framework is presented for assessing the potential effects of short-term, system-wide inhalation exposures that could result from such activities during a contamination event. This framework utilizes available statistical models for showering frequency and duration, available exposure models for showering and humidifier use, and experimental results on both aerosol generation and themore » volatilization of chemicals during showering. New models for the times when showering occurs are developed using time-use data for the United States. Given a lack of similar models for how humidifiers are used, or the information needed to develop them, an analysis of the sensitivity of results to assumptions concerning humidifier use is presented. The framework is applied using network models for three actual WDSs. Simple models are developed for estimating upper bounds on the potential effects of system-wide inhalation exposures associated with showering and humidifier use. From a system-wide, population perspective, showering could result in significant inhalation doses of volatile chemical contaminants, and humidifier use could result in significant inhalation doses of microbial contaminants during a contamination event. From a system-wide perspective, showering is unlikely to be associated with significant doses of microbial contaminants. In conclusion, given the potential importance of humidifiers as a source of airborne contaminants during a contamination event, an improved understanding of the nature of humidifier use is warranted.« less

  1. Landfill-stimulated iron reduction and arsenic release at the Coakley Superfund Site (NH).

    PubMed

    deLemos, Jamie L; Bostick, Benjamin C; Renshaw, Carl E; Stürup, Stefan; Feng, Xiahong

    2006-01-01

    Arsenic is a contaminant at more than one-third of all Superfund Sites in the United States. Frequently this contamination appearsto resultfrom geochemical processes rather than the presence of a well-defined arsenic source. Here we examine the geochemical processes that regulate arsenic levels at the Coakley Landfill Superfund Site (NH), a site contaminated with As, Cr, Pb, Ni, Zn, and aromatic hydrocarbons. Long-term field observations indicate that the concentrations of most of these contaminants have diminished as a result of treatment by monitored natural attenuation begun in 1998; however, dissolved arsenic levels increased modestly over the same interval. We attribute this increase to the reductive release of arsenic associated with poorly crystalline iron hydroxides within a glaciomarine clay layer within the overburden underlying the former landfill. Anaerobic batch incubations that stimulated iron reduction in the glaciomarine clay released appreciable dissolved arsenic and iron. Field observations also suggest that iron reduction associated with biodegradation of organic waste are partly responsible for arsenic release; over the five-year study period since a cap was emplaced to prevent water flow through the site, decreases in groundwater dissolved benzene concentrations at the landfill are correlated with increases in dissolved arsenic concentrations, consistent with the microbial decomposition of both benzene and other organics, and reduction of arsenic-bearing iron oxides. Treatment of contaminated groundwater increasingly is based on stimulating natural biogeochemical processes to degrade the contaminants. These results indicate that reducing environments created within organic contaminant plumes may release arsenic. In fact, the strong correlation (>80%) between elevated arsenic levels and organic contamination in groundwater systems at Superfund Sites across the United States suggests that arsenic contamination caused by natural degradation of organic contaminants may be widespread.

  2. Assessing Inhalation Exposures Associated with Contamination Events in Water Distribution Systems

    PubMed Central

    Davis, Michael J.; Janke, Robert; Taxon, Thomas N.

    2016-01-01

    When a water distribution system (WDS) is contaminated, short-term inhalation exposures to airborne contaminants could occur as the result of domestic water use. The most important domestic sources of such exposures are likely to be showering and the use of aerosol-producing humidifiers, i.e., ultrasonic and impeller (cool-mist) units. A framework is presented for assessing the potential effects of short-term, system-wide inhalation exposures that could result from such activities during a contamination event. This framework utilizes available statistical models for showering frequency and duration, available exposure models for showering and humidifier use, and experimental results on both aerosol generation and the volatilization of chemicals during showering. New models for the times when showering occurs are developed using time-use data for the United States. Given a lack of similar models for how humidifiers are used, or the information needed to develop them, an analysis of the sensitivity of results to assumptions concerning humidifier use is presented. The framework is applied using network models for three actual WDSs. Simple models are developed for estimating upper bounds on the potential effects of system-wide inhalation exposures associated with showering and humidifier use. From a system-wide, population perspective, showering could result in significant inhalation doses of volatile chemical contaminants, and humidifier use could result in significant inhalation doses of microbial contaminants during a contamination event. From a system-wide perspective, showering is unlikely to be associated with significant doses of microbial contaminants. Given the potential importance of humidifiers as a source of airborne contaminants during a contamination event, an improved understanding of the nature of humidifier use is warranted. PMID:27930709

  3. Failure Analysis of Nonvolatile Residue (NVR) Analyzer Model SP-1000

    NASA Technical Reports Server (NTRS)

    Potter, Joseph C.

    2011-01-01

    National Aeronautics and Space Administration (NASA) subcontractor Wiltech contacted the NASA Electrical Lab (NE-L) and requested a failure analysis of a Solvent Purity Meter; model SP-IOOO produced by the VerTis Instrument Company. The meter, used to measure the contaminate in a solvent to determine the relative contamination on spacecraft flight hardware and ground servicing equipment, had been inoperable and in storage for an unknown amount of time. NE-L was asked to troubleshoot the unit and make a determination on what may be required to make the unit operational. Through the use of general troubleshooting processes and the review of a unit in service at the time of analysis, the unit was found to be repairable but would need the replacement of multiple components.

  4. Contamination control requirements implementation for the James Webb Space Telescope (JWST), part 2: spacecraft, sunshield, observatory, and launch

    NASA Astrophysics Data System (ADS)

    Wooldridge, Eve M.; Schweiss, Andrea; Henderson-Nelson, Kelly; Woronowicz, Michael; Patel, Jignasha; Macias, Matthew; McGregor, R. Daniel; Farmer, Greg; Schmeitzky, Olivier; Jensen, Peter; Rumler, Peter; Romero, Beatriz; Breton, Jacques

    2014-09-01

    This paper will continue from Part 1 of JWST contamination control implementation. In addition to optics, instruments, and thermal vacuum testing, JWST also requires contamination control for a spacecraft that must be vented carefully in order to maintain solar array and thermal radiator thermal properties; a tennis court-sized sunshield made with 1-2 mil Kapton™ layers that must be manufactured and maintained clean; an observatory that must be integrated, stowed and transported to South America; and a rocket that typically launches commercial payloads without contamination sensitivity. An overview of plans developed to implement contamination control for the JWST spacecraft, sunshield, observatory and launch vehicle will be presented.

  5. DEMOLISHING A COLD-WAR-ERA FUEL STORAGE BASIN SUPERSTRUCTURE LADEN WITH ASBESTOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LLOYD ER; ORGILL TK; DAGAN EB

    The K East (KE) Basin facilities are located near the north end of the Hanford Site's 100 K area. The facilities were built in 1950 as part of the KE Reactor complex and constructed within 400 meters of the Columbia River, which is the largest river in the Pacific Northwest and by volume the fourth largest river in the United States. The basin, located adjacent to the reactor, was used for the underwater storage of irradiated nuclear fuel discharged from the reactor. The basin was covered by a superstructure comprising steel columns and beams, concrete, and cement asbestos board (CAB)more » siding. The project's mission was to complete demolition of the structure over the K East basin within six months of tumover from facility deactivation activities. The demolition project team implemented open-air demolition techniques to demolish the facility to slab-on-grade. Several innovative techniques were used to control contamination and maintain contamination control within the confines of the demolition exclusion zone. The techniques, which focused on a defense-in-depth approach, included spraying fixatives on interior and exterior surfaces before demolition began; applying fixatives; misting using a fine spray of water during demolition; and demolishing the facility systematically. Another innovation that aided demolition was to demolish the building with the non-friable CAB remaining in place. The CAB siding covered the exterior of the building, portions of the interior walls, and was an integral part of the multiple layered roof. The project evaluated the risks involved in removing the CAB material in a radiologically contaminated environment and determined that radiological dose rates and exposure to radiological contamination and industrial hazards would be significantly reduced by removing the CAB during demolition using heavy equipment. The ability to perform this demolition safely and without spreading contamination (radiological or asbestos) demonstrates that similar open-air demolition ofcontaminated structures can be performed successfully.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    BENNETT,D.B.; PAQUETTE,D.E.; KLAUS,K.

    The BNL water supply system meets all water quality standards and has sufficient pumping and storage capacity to meet current and anticipated future operational demands. Because BNL's water supply is drawn from the shallow Upper Glacial aquifer, BNL's source water is susceptible to contamination. The quality of the water supply is being protected through (1) a comprehensive program of engineered and operational controls of existing aquifer contamination and potential sources of new contamination, (2) groundwater monitoring, and (3) potable water treatment. The BNL Source Water Assessment found that the source water for BNL's Western Well Field (comprised of Supply Wellsmore » 4, 6, and 7) has relatively few threats of contamination and identified potential sources are already being carefully managed. The source water for BNL's Eastern Well Field (comprised of Supply Wells 10, 11, and 12) has a moderate number of threats to water quality, primarily from several existing volatile organic compound and tritium plumes. The g-2 Tritium Plume and portions of the Operable Unit III VOC plume fall within the delineated source water area for the Eastern Well Field. In addition, portions of the much slower migrating strontium-90 plumes associated with the Brookhaven Graphite Research Reactor, Waste Concentration Facility and Building 650 lie within the Eastern source water area. However, the rate of travel in the aquifer for strontium-90 is about one-twentieth of that for tritium and volatile organic compounds. The Laboratory has been carefully monitoring plume migration, and has made adjustments to water supply operations. Although a number of BNL's water supply wells were impacted by VOC contamination in the late 1980s, recent routine analysis of water samples from BNL's supply wells indicate that no drinking water standards have been reached or exceeded. The high quality of the water supply strongly indicates that the operational and engineered controls implemented over the past ten years have effectively protected the quality of the water supply.« less

  7. Investigation of Contaminated Ground Water at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina, 2006-2007

    USGS Publications Warehouse

    Vroblesky, Don A.; Petkewich, Matthew D.; Lowery, Mark A.; Conlon, Kevin J.; Harrelson, Larry G.

    2008-01-01

    The U.S. Geological Survey investigated natural and engineered remediation of chlorinated volatile organic compound (VOC) ground-water contamination at Solid Waste Management Unit 12 at the Naval Weapons Station Charleston, North Charleston, South Carolina, beginning in 2000. The primary contaminants of interest in the study are tetrachloroethene, 1,1,1-trichloroethane, trichloroethene, cis-1,2-dichloroethene, vinyl chloride, 1,1-dichloroethane, and 1,1-dichloroethene. The permeable reactive barrier (PRB) along the main axis of the contaminant plume appears to be actively removing contamination. In contrast to the central area of the PRB, the data from the southern end of the PRB indicate that contaminants are moving around the PRB. Concentrations in wells 12MW-10S and 12MW-03S, upgradient from the PRB, showed a general decrease in VOC concentrations. VOC concentrations in some wells in the forest showed a sharp increase, followed by a decrease. In 2007, the VOC concentrations began to increase in well 12MW-12S, downgradient from the PRB and thought to be unaffected by the PRB. The VOC-concentration changes in the forest, such as at well 12MW-12S, may represent lateral shifting of the plume in response to changes in ground-water-flow direction or may represent movement of a contamination pulse through the forest.

  8. Disgust and Contamination: A Cross-National Comparison of Ghana and the United States

    PubMed Central

    Skolnick, Alexander J.; Dzokoto, Vivian A.

    2012-01-01

    The emotion of disgust, with feelings of revulsion and behavioral withdrawal, make it a prime emotion to aid in the avoidance of sources of contamination, including sources of potential infectious disease. We tested the theory that living in a region with a historically high prevalence of infectious diseases would promote higher levels of disgust and contamination sensitivity as a protective measure. A sample of undergraduates from Ghana (n = 103, 57 women), a country with a historically high prevalence of infectious diseases, showed significantly higher scores on scales assessing disgust, contamination, and disease susceptibility than a sample of undergraduates from the United States (n = 96, 58 women), a country with lower levels of disease threat. Contamination sensitivity mediated the national differences in disgust. Disgust connoting contamination also produced larger cross-national effect sizes than other types of disgust. Finally, a factor analysis on the Ghanaian responses to one of the disgust scales did not resemble the usual three-factor solution found in West. Taken together, the results were consistent with the hypothesis that a region with a higher prevalence of infectious disease threats would produce greater sensitivity to disgust and contamination than seen in lower disease threat regions. This first study on disgust in Africa showed that disgust sensitivity could differ considerably from that in the West. PMID:23450744

  9. Quality of Source Water from Public-Supply Wells in the United States, 1993-2007

    USGS Publications Warehouse

    Toccalino, Patricia L.; Norman, Julia E.; Hitt, Kerie J.

    2010-01-01

    More than one-third of the Nation's population receives their drinking water from public water systems that use groundwater as their source. The U.S. Geological Survey (USGS) sampled untreated source water from 932 public-supply wells, hereafter referred to as public wells, as part of multiple groundwater assessments conducted across the Nation during 1993-2007. The objectives of this study were to evaluate (1) contaminant occurrence in source water from public wells and the potential significance of contaminant concentrations to human health, (2) national and regional distributions of groundwater quality, and (3) the occurrence and characteristics of contaminant mixtures. Treated finished water was not sampled. The 932 public wells are widely distributed nationally and include wells in selected parts of 41 states and withdraw water from parts of 30 regionally extensive aquifers used for public water supply. These wells are distributed among 629 unique public water systems-less than 1 percent of all groundwater-supplied public water systems in the United States-but the wells were randomly selected within the sampled hydrogeologic settings to represent typical aquifer conditions. Samples from the 629 systems represent source water used by one-quarter of the U.S. population served by groundwater-supplied public water systems, or about 9 percent of the entire U.S. population in 2008. One groundwater sample was collected prior to treatment or blending from each of the 932 public wells and analyzed for as many as six water-quality properties and 215 contaminants. Consistent with the terminology used in the Safe Drinking Water Act (SDWA), all constituents analyzed in water samples in this study are referred to as 'contaminants'. More contaminant groups were assessed in this study than in any previous national study of public wells and included major ions, nutrients, radionuclides, trace elements, pesticide compounds, volatile organic compounds (VOCs), and fecal-indicator microorganisms. Contaminant mixtures were assessed in subsets of samples in which most contaminants were analyzed. Contaminant concentrations were compared to human-health benchmarks-regulatory U.S. Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) for contaminants regulated in drinking water under the SDWA or non-regulatory USGS Health-Based Screening Levels (HBSLs) for unregulated contaminants, when available. Nearly three-quarters of the contaminants assessed in this study are unregulated in drinking water, and the USEPA uses USGS data on the occurrence of unregulated contaminants in water resources to fulfill part of the SDWA requirements for determining whether specific contaminants should be regulated in drinking water in the future. More than one in five (22 percent) source-water samples from public wells contained one or more naturally occurring or man-made contaminants at concentrations greater than human-health benchmarks, and 80 percent of samples contained one or more contaminants at concentrations greater than one-tenth of benchmarks. Most individual contaminant detections, however, were less than one-tenth of human-health benchmarks. Public wells yielding water with contaminant concentrations greater than benchmarks, as well as those with concentrations greater than one-tenth of benchmarks, were distributed throughout the United States and included wells that withdraw water from all principal aquifer rock types included in this study. Ten contaminants individually were detected at concentrations greater than human-health benchmarks in at least 1 percent of source-water samples and collectively accounted for most concentrations greater than benchmarks. Seven of these 10 contaminants occur naturally, including three radionuclides (radon, radium, and gross alpha-particle radioactivity) and four trace elements (arsenic, manganese, strontium, and boron); three of these 10 contaminants (dieldrin, nitrate, and perchl

  10. Advances in Dynamic Transport of Organic Contaminants in Karst Groundwater Systems

    NASA Astrophysics Data System (ADS)

    Padilla, I. Y.; Vesper, D.; Alshawabkeh, A.; Hellweger, F.

    2011-12-01

    Karst groundwater systems develop in soluble rocks such as limestone, and are characterized by high permeability and well-developed conduit porosity. These systems provide important freshwater resources for human consumption and ecological integrity of streams, wetlands, and coastal zones. The same characteristics that make karst aquifers highly productive make them highly vulnerable to contamination. As a result, karst aquifers serve as an important route for contaminants exposure to humans and wildlife. Transport of organic contaminants in karst ground-water occurs in complex pathways influenced by the flow mechanism predominating in the aquifer: conduit-flow dominated systems tend to convey solutes rapidly through the system to a discharge point without much attenuation; diffuse-flow systems, on the other hand, can cause significant solute retardation and slow movement. These two mechanisms represent end members of a wide spectrum of conditions found in karst areas, and often a combination of conduit- and diffuse-flow mechanisms is encountered, where both flow mechanisms can control the fate and transport of contaminants. This is the case in the carbonate aquifers of northern Puerto Rico. This work addresses advances made on the characterization of fate and transport processes in karst ground-water systems characterized by variable conduit and/or diffusion dominated flow under high- and low-flow conditions. It involves laboratory-scale physical modeling and field-scale sampling and historical analysis of contaminant distribution. Statistical analysis of solute transport in Geo-Hydrobed physical models shows the heterogeneous character of transport dynamics in karstic units, and its variability under different flow regimes. Field-work analysis of chlorinated volatile organic compounds and phthalates indicates a large capacity of the karst systems to store and transmit contaminants. This work is part of the program "Puerto Rico Testsite for Exploring Contamination Threats (PRoTECT)" supported by the National Institute of Environmental Health Sciences (NIEHS, Grant Award No. P42ES017198).

  11. Pharmaceuticals, hormones, personal-care products, and other organic wastewater contaminants in water resources: Recent research activities of the U.S. Geological Survey's toxic substances hydrology program

    USGS Publications Warehouse

    Focazio, Michael J.; Kolpin, Dana W.; Buxton, Herbert T.

    2003-01-01

    Recent decades have brought increasing concerns for potential contamination of water resources that could inadvertently result during production, use, and disposal of the numerous chemicals offering improvements in industry, agriculture, medical treatment, and even common household products. Increasing knowledge of the environmental occurrence or toxicological behavior of these contaminants from various studies in Europe, United States, and elsewhere has resulted in increased concern for potential adverse environmental and human health effects (Daughton and Ternes, 1999). Ecologists and public health experts often have incomplete understandings of the toxicological significance of many of these contaminants, particularly long-term, low-level exposure and when they occur in mixtures with other contaminants (Daughton and Ternes, 1999; Kümmerer, 2001). In addition, these ‘emerging contaminants’ are not typically monitored or assessed in ambient water resources. The need to understand the processes controlling the transport and fate of these contaminants in the environment, and the lack of knowledge of the significance of long-term exposures have increased the need to study environmental occurrence down to trace (nanogram per liter) levels. Furthermore, the possibility that mixtures of environmental contaminants may interact synergistically or antagonistically has increased the need to characterize the types of mixtures that are found in our waters. The U.S. Geological Survey’s Toxic Substances Hydrology Program (Toxics Program) is developing information and tools on emerging water-quality issues that will be used to design and improve water-quality monitoring and assessment programs of the USGS and others, and for proactive decision-making by industry, regulators, the research community, and the public (http://toxics.usgs.gov/regional/emc.html). This research on emerging water-quality issues includes a combination of laboratory work to develop new analytical capabilities as well as field work on the occurrence, fate, and effects of these contaminants.

  12. Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

    PubMed

    Stucki, Cyril; Sautter, Anna-Maria; Favet, Jocelyne; Bonnabry, Pascal

    2009-11-15

    The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated. Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes. Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p < 0.0001). Certain high-risk manipulations were associated with a significant increase in the contamination of the surrogate syringes, including exposure to nonsterile ambient air and nonsterile objects or fingers (p < 0.0001). High contamination rates were measured when the hub of syringes touched nonsterile environmental surfaces and fingers, whereas the drawn-air manipulation was associated with a lower risk of contamination. Working within a properly operating unidirectional airflow primary engineering control in an ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

  13. Effect of fecal contamination and cross-contamination on numbers of coliform, Escherichia coli, Campylobacter, and Salmonella on immersion-chilled broiler carcasses.

    PubMed

    Smith, D P; Cason, J A; Berrang, M E

    2005-07-01

    The effect of prechill fecal contamination on numbers of bacteria on immersion-chilled carcasses was tested in each of three replicate trials. For each trial, 16 eviscerated broiler carcasses were split into 32 halves and assigned to one of two groups. Cecal contents (0.1 g inoculated with Campylobacter and nalidixic acid-resistant Salmonella) were applied to each of eight halves in one group (direct contamination) that were placed into one paddle chiller (contaminated), whereas the other paired halves were placed into another chiller (control). From the second group of eight split birds, one of each paired half was placed in the contaminated chiller (to determine cross-contamination) and the other half was placed in the control chiller. Postchill carcass halves were sampled by a 1-min rinse in sterile water, which was collected and cultured. Bacterial counts were reported as log CFU per milliliter of rinsate. There were no significant statistical differences (paired t test, P < 0.05) from direct contamination for coliforms (mean 3.0 log CFU) and Escherichia coli (mean 2.7 log CFU), although Campylobacter numbers significantly increased from control values because of direct contamination (1.5 versus 2.1 log CFU), and the incidence increased from 79 to 100%. There was no significant effect of cross-contamination on coliform (mean 2.9 log CFU) or E. coli (mean 2.6 log CFU) numbers. Nevertheless, Campylobacter levels were significantly higher after exposure to cross-contamination (1.6 versus 2.0 log CFU), and the incidence of this bacterium increased from 75 to 100%. Salmonella-positive halves increased from 0 to 42% postchill because of direct contamination and from 0 to 25% as a result of cross-contamination after chilling. Water samples and surface swabs taken postchill from the contaminated chiller were higher for Campylobacter than those taken from the control chiller. Immersion chilling equilibrated bacterial numbers between contaminated and control halves subjected to either direct contamination or cross-contamination for coliforms and E. coli. Campylobacter numbers, Campylobacter incidence, and Salmonella incidence increased because of both direct contamination and cross-contamination in the chiller. Postchill E. coli numbers did not indicate which carcass halves were contaminated with feces before chilling.

  14. Potential urban runoff impacts and contaminant distributions in shoreline and reservoir environments of Lake Havasu, southwestern United States.

    PubMed

    Wilson, Doyle C

    2018-04-15

    Heavy metal, nutrient, and hydrocarbon levels in and adjacent to Lake Havasu, a regionally significant water supply reservoir with a highly controlled, dynamic flow regime, are assessed in relation to possible stormwater runoff impacts from an arid urban center. Shallow groundwater and sediment analyses from ephemeral drainage (wash) mouths that convey stormwater runoff from Lake Havasu City, Arizona to the reservoir, provided contaminant control points and correlation ties with the reservoir environment. Fine-grain sediments tend to contain higher heavy metal concentrations whereas nutrients are more evenly distributed, except low total organic carbon levels from young wash mouth surfaces devoid of vegetation. Heavy metal and total phosphate sediment concentrations in transects from wash mouths into the reservoir have mixed and decreasing trends, respectively. Both series may indicate chemical depositional influences from urban runoff, yet no statistically significant concentration differences occur between specific wash mouths and corresponding offshore transects. Heavy metal pollution indices of all sediments indicate no discernible to minor contamination, indicating that runoff impacts are minimal. Nevertheless, several heavy metal concentrations from mid-reservoir sediment sites increase southward through the length of the reservoir. Continual significant water flow through the reservoir may help to disperse locally derived runoff particulates, which could mix and settle down gradient with chemical loads from upriver sources and local atmospheric deposition. Incorporating the shoreline environment with the reservoir investigation provides spatial continuity in assessing contaminant sources and distribution patterns. This is particularly acute in the investigation of energetic, flow-through reservoirs in which sources may be overlooked if solely analyzing the reservoir environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Genome-Wide Transcriptome Analysis of Cotton (Gossypium hirsutum L.) Identifies Candidate Gene Signatures in Response to Aflatoxin Producing Fungus Aspergillus flavus.

    PubMed

    Bedre, Renesh; Rajasekaran, Kanniah; Mangu, Venkata Ramanarao; Sanchez Timm, Luis Eduardo; Bhatnagar, Deepak; Baisakh, Niranjan

    2015-01-01

    Aflatoxins are toxic and potent carcinogenic metabolites produced from the fungi Aspergillus flavus and A. parasiticus. Aflatoxins can contaminate cottonseed under conducive preharvest and postharvest conditions. United States federal regulations restrict the use of aflatoxin contaminated cottonseed at >20 ppb for animal feed. Several strategies have been proposed for controlling aflatoxin contamination, and much success has been achieved by the application of an atoxigenic strain of A. flavus in cotton, peanut and maize fields. Development of cultivars resistant to aflatoxin through overexpression of resistance associated genes and/or knocking down aflatoxin biosynthesis of A. flavus will be an effective strategy for controlling aflatoxin contamination in cotton. In this study, genome-wide transcriptome profiling was performed to identify differentially expressed genes in response to infection with both toxigenic and atoxigenic strains of A. flavus on cotton (Gossypium hirsutum L.) pericarp and seed. The genes involved in antifungal response, oxidative burst, transcription factors, defense signaling pathways and stress response were highly differentially expressed in pericarp and seed tissues in response to A. flavus infection. The cell-wall modifying genes and genes involved in the production of antimicrobial substances were more active in pericarp as compared to seed. The genes involved in auxin and cytokinin signaling were also induced. Most of the genes involved in defense response in cotton were highly induced in pericarp than in seed. The global gene expression analysis in response to fungal invasion in cotton will serve as a source for identifying biomarkers for breeding, potential candidate genes for transgenic manipulation, and will help in understanding complex plant-fungal interaction for future downstream research.

  16. Contamination of dental unit waterlines: assessment of three continuous water disinfection systems

    PubMed Central

    Offner, Damien; Fioretti, Florence; Musset, Anne-Marie

    2016-01-01

    Objectives: To assess the efficacy of three continuous water disinfection systems for dental units under real conditions of dental care. Design and settings: A prospective study carried out from 45 days to 20 months on the water microbial quality of the dental units is benefited from three different systems: two chemical treatment systems (IGN EVO/Calbenium/IGN Cartridge and Sterispray) and one physical treatment system (BacTerminator). Studied items were six dental units of the Dental Medicine and Oral Surgery Center within the University Hospital of Strasbourg (HUS), France. Results and disucussion: The IGN EVO/Calbenium/IGN Cartridge and Sterispray systems showed an immediate and long-term efficacy on contaminated dental unit waterlines. However, the first system offers ergonomic advantages (automatic system, action on the water from the water supply network). The BacTerminator system took longer to be effective and was less effective than the other two. PMID:29607068

  17. Experimental study of the constituents of space wash water

    NASA Technical Reports Server (NTRS)

    Putnam, D. F.; Colombo, G. V.

    1975-01-01

    This report presents experimental data, obtained under controlled conditions, which quantify the various constituents of human origin that may be expected in space wash water. The experiments were conducted with a simulated crew of two male and two female subjects. The data show that the expected wash water contaminants originating from human secretions are substantially lower than theoretical projections indicated. The data presented are immediately useful and may have considerable impact on the tradeoff comparisons among various unit processes and systems under consideration by NASA for recycling space wash water.

  18. By-products of the Thermal Treatment of Hazardous Waste: Formation and Health Effects

    PubMed Central

    Walsh, Maud; Cormier, Stephania; Varner, Kurt; Dellinger, Barry

    2011-01-01

    Destruction of toxic chemicals by thermal treatment can be a highly effective method for remediation of sites contaminated with hazardous substances. Of the 977 Superfund source control treatment projects in the United States from 1982 to 2005, 16% used incineration or other thermal treatments (the proportion is similar for 126 projects in the period 2002–2005).1 However, as with other technologies, if thermal treatments are not matched correctly with the site or are improperly operated, harmful by-products can form, requiring further treatment. PMID:22684359

  19. Performance of International Space Station Alpha Trace Contaminant Control Systems

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    2016-01-01

    The analysis presented herein was conducted during the early transitional period between the Space Station Freedom and the International Space Station programs as part of an effort to evaluate key design specifications and standards used by the United States and Russia. The analysis was originally documented under NASA cover letter ED62(36-94) dated August 16, 1994. The analysis was revised and rereleased under NASA cover letter ED62(51-94) dated November 14, 1994. These cover letters are provided here to guide programmatic context for the reader.

  20. Superfund record of decision (EPA Region 3): Ohio River Park Site, Operable Unit 3, Neville Island, PA, September 17, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-10-01

    This Record of Decision (ROD) presents the selected remedial action plan for the Ohio River Park Superfund Site (the Site) in Allegheny County, Pennsylvania. The remedial action plan in this document is presented as the permanent remedy for controlling the groundwater at the Site. This remedy is comprised of: monitoring of natural attenuation processes to measure changes in contaminant concentrations in groundwater plume at the Site until the cleanup levels are achieved; deed restriction preventing residential use of groundwater at the Site.

  1. External Contamination Control of Attached Payloads on the International Space Station

    NASA Technical Reports Server (NTRS)

    Soares, Carlos E.; Mikatarian, Ronald R.; Olsen, Randy L.; Huang, Alvin Y.; Steagall, Courtney A.; Schmidl, William D.; Wright, Bruce D.; Koontz, Steven

    2012-01-01

    The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.

  2. Preventing central venous catheter-associated bloodstream infections: development of an antiseptic barrier cap for needleless connectors.

    PubMed

    Menyhay, Steve Z; Maki, Dennis G

    2008-12-01

    Reports of outbreaks associated with the use of needle-free valve connectors suggest 2 common risk factors: (1) poor adherence to disinfection practices before use and (2) a design that allows contamination when not in use. Swabbing a membranous septum with 70% isopropyl alcohol may not eliminate septal surface contamination. Frequent access through and handling of needle-free connectors also puts patients at increased risk of central venous catheter-related bloodstream infections (CR-BSIs). A novel antiseptic barrier cap has been designed to maintain health care worker safety and eliminate the vulnerabilities of existing systems to contamination and CR-BSIs for patients at risk. A prospective in vitro study compared the effectiveness of standard disinfection of needleless luer-activated valve connectors with 70% isopropyl alcohol and the effectiveness of an antiseptic barrier cap that, when threaded onto a luer-activated connector, rapidly sterilizes a heavily contaminated surface. Standard disinfection was done by 3- to 5-second swabbing using a sterile commercial pledget of 70% isopropyl alcohol. The antiseptic barrier cap comprises an outer cap with internal female threads and a spike inside the closed end, a capsule containing 0.25 mL of 2% chlorhexidine gluconate in 70% isopropyl alcohol, and a sponge between the septum and the capsule. When the cap is threaded onto a luer-adaptable needleless connector, the spike ruptures the capsule, saturating the sponge with the antiseptic. All 15 (100%) of the precontaminated positive control connectors not disinfected before entry showed transmission of Enterococcus faecalis across the membranous septum (4500-28,000 colony-forming units), and 20 (67%) of 30 connectors disinfected with 70% alcohol showed transmission (442-25,000 colony-forming units). Of 60 needle-free connectors disinfected with the antiseptic barrier cap, 1 (1.6%) showed transmission (P < .001). An antiseptic barrier cap was highly effective in sterilizing the septum of a needle-free valve connector and preventing entry of any microorganisms, even with heavy contamination of the septum. This new technology should now be evaluated in a clinical trial with CR-BSI as the primary outcome measure.

  3. Environmental Chemistry Principles in Site Remediation (CEECHE 2018 Krakow Poland)

    EPA Science Inventory

    In CEECHE meeting, we will present scientific, engineering information and case studies on sustainable and innovative remediation technologies used in contaminated sites in Europe and the United States. One of the most important tasks to be performed to remediate contaminated si...

  4. CULTURE-INDEPENDENT MOLECULAR METHODS FOR FECAL SOURCE IDENTIFICATION

    EPA Science Inventory

    Fecal contamination is widespread in the waterways of the United States. Both to correct the problem, and to estimate public health risk, it is necessary to identify the source of the contamination. Several culture-independent molecular methods for fecal source identification hav...

  5. What Is Pneumonia?

    MedlinePlus

    ... following are three fungi that occur in the soil in some parts of the United States and ... throughout the United States in bird droppings and soil contaminated with bird droppings. Risk Factors Many factors ...

  6. [Decontamination of dental unit waterlines using disinfectants and filters].

    PubMed

    Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L

    2002-10-01

    Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.

  7. The pathogenesis of ventilator-associated pneumonia: its relevance to developing effective strategies for prevention.

    PubMed

    Safdar, Nasia; Crnich, Christopher J; Maki, Dennis G

    2005-06-01

    Ventilator-associated pneumonia (VAP) is the most common nosocomial infection in the intensive care unit and is associated with major morbidity and attributable mortality. Strategies to prevent VAP are likely to be successful only if based upon a sound understanding of pathogenesis and epidemiology. The major route for acquiring endemic VAP is oropharyngeal colonization by the endogenous flora or by pathogens acquired exogenously from the intensive care unit environment, especially the hands or apparel of health-care workers, contaminated respiratory equipment, hospital water, or air. The stomach represents a potential site of secondary colonization and reservoir of nosocomial Gram-negative bacilli. Endotracheal-tube biofilm formation may play a contributory role in sustaining tracheal colonization and also have an important role in late-onset VAP caused by resistant organisms. Aspiration of microbe-laden oropharyngeal, gastric, or tracheal secretions around the cuffed endotracheal tube into the normally sterile lower respiratory tract results in most cases of endemic VAP. In contrast, epidemic VAP is most often caused by contamination of respiratory therapy equipment, bronchoscopes, medical aerosols, water (eg, Legionella) or air (eg, Aspergillus or the severe acute respiratory syndrome virus). Strategies to eradicate oropharyngeal and/or intestinal microbial colonization, such as with chlorhexidine oral care, prophylactic aerosolization of antimicrobials, selective aerodigestive mucosal antimicrobial decontamination, or the use of sucralfate rather than H(2) antagonists for stress ulcer prophylaxis, and measures to prevent aspiration, such as semirecumbent positioning or continuous subglottic suctioning, have all been shown to reduce the risk of VAP. Measures to prevent epidemic VAP include rigorous disinfection of respiratory equipment and bronchoscopes, and infection-control measures to prevent contamination of medical aerosols. Hospital water should be Legionella-free, and high-risk patients, especially those with prolonged granulocytopenia or organ transplants, should be cared for in hospital units with high-efficiency-particulate-arrestor (HEPA) filtered air. Routine surveillance of VAP, to track endemic VAPs and facilitate early detection of outbreaks, is mandatory.

  8. Listeria, Then and Now: A Call to Reevaluate Patient Teaching Based on Analysis of US Federal Databases, 1998-2016.

    PubMed

    Simon, Katya; Simon, Valentina; Rosenzweig, Rachel; Barroso, Rebeca; Gillmor-Kahn, Mickey

    2018-05-01

    Listeria monocytogenes is a foodborne pathogen capable of crossing the placental-fetal barrier; infection with the bacterium causes listeriosis. An exposed fetus may suffer blindness, neurological damage including meningitis, or even death. The adverse consequences of listeriosis place the infection on the federally reportable disease list. Primary prevention relies on women avoiding 6 categories of foods most likely to be contaminated with L monocytogenes, as indicated in guidelines developed by the Centers for Disease Control and Prevention (CDC), adapted by the American College of Obstetricians and Gynecologists (ACOG) in 2014, and reaffirmed without changes by ACOG in 2016. This report contains a critical evaluation of United States listeriosis prevention guidelines. Between 1998 and 2016, there were 876 identified listeriosis events documented in the illness and recall databases maintained by the CDC, Food and Drug Administration (FDA), and United States Department of Agriculture - Food Safety and Inspection Service (USDA-FSIS). Each contaminated food was manually compared to the existing listeriosis avoidance guidelines, placing each event within or outside the guidelines. Trends were analyzed over time. Database analysis demonstrates that prior to the year 2000, abiding by the current guidelines would have prevented all reported listeriosis cases. However, in 2015 and 2016, only 5% of confirmed L monocytogenes infections originated from the 6 food groups listed in the CDC and ACOG guidelines. Similar trends emerged for food processing plant recalls (USDA-FSIS database) and grocery store recalls (FDA database). The total number of listeriosis illnesses in the United States doubled from 2007 to 2014. A gradual shift in detection of L monocytogenes contamination in ready-to-eat meals, frozen foods, and ready-to-eat salads has occurred. Another emerging culprit is pasteurized dairy products. Revision of listeriosis avoidance guidelines by a consensus-seeking, multidisciplinary task force, is needed. © 2018 by the American College of Nurse-Midwives.

  9. [Evaluation of the bacteriologic quality of breast milk in a neonatology service in Belgium].

    PubMed

    Vervoort, A; Delsat, L; Pieltain, C; De Halleux, V; Carpentier, M; Rigo, J

    2007-03-01

    Many studies demonstrated that human milk is the recommended source of enteral nutrition in preterm infants providing several benefits with regards to feeding tolerance, immunity and cognitive development However, neurological immaturity and associated clinical conditions prevent them from suckling effectively. Therefore, mother's milk must be expressed, stored and transported to the neonatal unit and could be contaminated. The microbiological quality of human milk was evaluated on each donation to the neonatal intensive care unit of the University of Liege, Belgium from November 1, 2003 to January 31, 2005. In all, 5842 samples from 176 mothers were included in the study. Samples were classified according to the exclusive presence of coagulase negative Staphylococcus and their number (less or more than 104 germs per ml) or to contamination with pathogens. More than 50% of analyzed milks had to be pasteurized (46%; >104 coagulase negative Staphylococcus per ml) or to be discarded (7% pathogen contamination). The incidence of pasteurisation tends to increase during the summer, suggesting a seasonal influence. Maternal profiles were established longitudinally. Among the 60 mothers whose at least one sample had pathogen contamination, 27% had a contamination occurring only during a few days, but 73% had more than 50% of their samples discarded. This study suggest the need to promote the use and the financial support of intrahospital human milk bank units to support the safe use of raw and pasteurised human milk in preterm infants.

  10. Superfund record of decision amendment (EPA Region 10): USAF Eielson Air Force Base, Operable Units 3, 4, and 5, Fairbanks North Star Borough, AK, September 29, 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This decision document presents the amended remedial action for Operable Units 3, 4, and 5 (OUs 3, 4, and 5) at Eielson Air Force Base (AFB). This decision is based on the Administrative Record for OU 3, 4, and 5, updated in July 1998, to include new information generated since the original Record of Decision was signed on 30 September 1995 (PB95-964618). This amendment applies to OU3 site DP44 (Battery Shop Leach Field Building), OU4 sites SS35 (Asphalt Mixing Area) and ST58 (Old Quartermaster Service Station), and OU5 sites LF03/FT09 (Current Inactive Base Landfill/Fire Training Area). Through new information, contaminantmore » levels than interpreted prior to signing the original ROD document. Proper enforcement of Institutional Controls (IC`s) at all sites will be effective in controlling and restricting access to contaminated media at the sites remediation goals are achieved.« less

  11. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Surface oxide removal by a XeCl laser for decontamination

    NASA Astrophysics Data System (ADS)

    Sentis, M. L.; Delaporte, Ph; Marine, W.; Uteza, O.

    2000-06-01

    The laser ablation performed with an automated excimer XeCl laser unit is used for large surface cleaning. The study focuses on metal surfaces that are oxidised and are representative of contaminated surfaces with radionuclides in a context of nuclear power plant maintenance. The unit contains an XeCl laser, the beam delivery system, the particle collection cell, and the system for real-time control of cleaning processes. The interaction of laser radiation with a surface is considered, in particular, the surface damage caused by cleaning radiation. The beam delivery system consists of an optical fibre bundle of 5 m long and allows delivering 150 W at 308 nm for laser surface cleaning. The cleaning process is controlled by analysing in real time the plasma electric field evolution. The system permits the cleaning of 2 to 6 m2 h-1 of oxides with only slight substrate modifications.

  12. Browns Ferry Nuclear Plant Unit 2: Control rod drive scram discharge headers decontamination effort

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Traynor, J.C.

    1983-08-01

    The control rod drive (CRD) scram discharge headers were decontaminated during the Browns Ferry unit 2, cycle 4 refueling outage (August 2-5, 1982). Hydrolasing (high-pressure water blasting) was used as the method of decontamination to remove fixed and loose radioactive contaminants from the headers. It was found that hydrolasing of the west scram discharge headers resulted in approximate maximum and average decontamination factors (DFs) on contact of 13 and 5, respectively. For the east scram discharge headers, hydrolasing resulted in a maximum and average DF on contact of approximately 3. The maximum and average DFs on contact for the individualmore » headers ranged from 1 to 33 and 1 to 10, respectively, while the walkway (head-level) DFs were in the range of 3 to 4. Higher DFs were impeded by inadequate drainage and backwashing of fluid. This led to increased radiation levels in some areas and recontamination of adjacent headers.« less

  13. Contaminated sinks in intensive care units: an underestimated source of extended-spectrum beta-lactamase-producing Enterobacteriaceae in the patient environment.

    PubMed

    Roux, D; Aubier, B; Cochard, H; Quentin, R; van der Mee-Marquet, N

    2013-10-01

    Extended-spectrum beta-lactamase-producing Enterobacteriaceae (ESBLE) outbreaks in intensive care units (ICUs) associated with contaminated handwashing sinks have been reported. To conduct a regional study to assess whether handwashing sinks in 135 ICU patient rooms are a potential source of contamination, and to identify factors associated with an increased risk of sink contamination. A multicentre study was conducted in 13 ICUs, including microbiological testing for ESBLE contamination at 185 sinks. The micro-organisms isolated were analysed using randomly amplified polymorphic DNA analysis to assess clonal spread in ICUs. Data were collected to document the use of each sink, factors that may contribute to contamination of clinical areas near to the sinks, and routine cleansing procedures for the sinks. Fifty-seven sinks were contaminated (31%) with ESBLE, mostly Klebsiella (N = 33) and Enterobacter (N = 18). In two ICUs, a high contamination rate was associated with clonal spread of an epidemic isolate. Risk factors for contamination of and by handwashing sinks were frequent: 81 sinks (44%) were used for handwashing as well as the disposal of body fluids; splash risk was identified for 67 sinks (36%), among which 23 were contaminated by ESBLE. Routine sink disinfection was frequent (85%), mostly daily (75%), and involved quaternary ammonium compounds (41%) or bleach (21%). A lower sink contamination rate was significantly associated with use of the sink being restricted to handwashing and to daily sink disinfection using bleach. In ICUs, contaminated sinks are a potential source of ESBLE in the environment of the patient, a problem that may be underestimated by ICU teams. Relatively simple measures may result in a rapid improvement of the situation, and a significant decrease of the risk of exposure of ICU patients to multiresistant Enterobacteriaceae. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Nitrate in aquifers beneath agricultural systems

    USGS Publications Warehouse

    Burkart, M.R.; Stoner, J.D.; ,

    2007-01-01

    Research from several regions of the world provides spatially anecdotal evidence to hypothesize which hydrologic and agricultural factors contribute to groundwater vulnerability to nitrate contamination. Analysis of nationally consistent measurements from the U.S. Geological Survey's NAWQA program confirms these hypotheses for a substantial range of agricultural systems. Shallow unconfined aquifers are most susceptible to nitrate contamination associated with agricultural systems. Alluvial and other unconsolidated aquifers are the most vulnerable and also shallow carbonate aquifers that provide a substantial but smaller contamination risk. Where any of these aquifers are overlain by permeable soils the risk of contamination is larger. Irrigated systems can compound this vulnerability by increasing leaching facilitated by additional recharge and additional nutrient applications. The system of corn, soybean, and hogs produced significantly larger concentrations of groundwater nitrate than all other agricultural systems because this system imports the largest amount of N-fertilizer per unit production area. Mean nitrate under dairy, poultry, horticulture, and cattle and grains systems were similar. If trends in the relation between increased fertilizer use and groundwater nitrate in the United States are repeated in other regions of the world, Asia may experience increasing problems because of recent increases in fertilizer use. Groundwater monitoring in Western and Eastern Europe as well as Russia over the next decade may provide data to determine if the trend in increased nitrate contamination can be reversed. If the concentrated livestock trend in the United States is global, it may be accompanied by increasing nitrogen contamination in groundwater. Concentrated livestock provide both point sources in the confinement area and intense non-point sources as fields close to facilities are used for manure disposal. Regions where irrigated cropland is expanding, such as in Asia, may experience the greatest impact of this practice on groundwater nitrate. ?? USDA 2007.

  15. Contaminated Frozen Strawberries in School Lunches. Hearing before the Committee on Agriculture, Nutrition, and Forestry. United States Senate, One Hundred Fifth Congress, First Session (June 5, 1997).

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Senate Committee on Agriculture, Nutrition, and Forestry.

    This hearing includes testimony on contaminated strawberries in school lunches. Contaminated strawberries were determined to be the cause of an outbreak of hepatitis in the state of Michigan. In addition to statements by the committee members, testimony was given by: (1) Mary Ann Keeffe, Acting Under Secretary, Food Nutrition and Consumer…

  16. Contamination movement around a permeable reactive barrier at Solid Waste Management Unit 12, Naval Weapons Station Charleston, North Charleston, South Carolina, 2009

    USGS Publications Warehouse

    Vroblesky, Don A.; Petkewich, Matthew D.; Conlon, Kevin J.

    2010-01-01

    The ability to monitor the fate and behavior of the plume in the forest is severely limited because the present axis of maximum contamination in that area bypasses all but one of the existing monitoring wells (12MW-12S). Moreover, the 2009 data indicate that there are no optimally placed sentinel wells in the probable path of contaminant transport. Thus the monitoring network is no longer adequate to monitor the groundwater contamination downgradient from the PRB.

  17. A low-cost intervention for cleaner drinking water in Karachi, Pakistan.

    PubMed

    Luby, S; Agboatwalla, M; Raza, A; Sobel, J; Mintz, E; Baier, K; Rahbar, M; Qureshi, S; Hassan, R; Ghouri, F; Hoekstra, R M; Gangarosa, E

    2001-01-01

    To pilot test an inexpensive, home-based water decontamination and storage system in a low-income neighborhood of Karachi. Fifty households received a 20-L plastic water storage vessel with a high-quality spout and a regular supply of diluted hypochlorite solution. Twenty-five control households were recruited. Water samples were collected at baseline and during unannounced follow-up visits 1, 3, 6, and 10 weeks later. Baseline drinking water samples among intervention households were contaminated with a mean 9397 colony-forming units (cfu)/100 mL of thermotolerant coliforms compared with a mean 10,990 cfu/100 mL from controls. After intervention the mean concentration of thermotolerant coliforms decreased by 99.8% among the intervention households compared with an 8% reduction among controls. Two years after vessel distribution, 34 (68%) of the families were still using the vessel. Thirteen of the households had stopped using their vessel because it had broken after more than 6 months of use, a pattern most consistent with ultraviolet radiation-induced degradation of the plastic. In a highly contaminated environment, a specifically designed water storage container and in-home water chlorination was acceptable and markedly improved water quality. Where plastic water vessels will be exposed to substantial sunlight, ultraviolet light stabilizers should be incorporated into the plastic.

  18. Control strategies against Campylobacter at the poultry production level: biosecurity measures, feed additives and vaccination.

    PubMed

    Meunier, M; Guyard-Nicodème, M; Dory, D; Chemaly, M

    2016-05-01

    Campylobacteriosis is the most prevalent bacterial foodborne gastroenteritis affecting humans in the European Union, and ranks second in the United States only behind salmonellosis. In Europe, there are about nine million cases of campylobacteriosis every year, making the disease a major public health issue. Human cases are mainly caused by the zoonotic pathogen Campylobacter jejuni. The main source of contamination is handling or consumption of poultry meat. Poultry constitutes the main reservoir of Campylobacter, substantial quantities of which are found in the intestines following rapid, intense colonization. Reducing Campylobacter levels in the poultry chain would decrease the incidence of human campylobacteriosis. As primary production is a crucial step in Campylobacter poultry contamination, controlling the infection at this level could impact the following links along the food chain (slaughter, retail and consumption). This review describes the control strategies implemented during the past few decades in primary poultry production, including the most recent studies. In fact, the implementation of biosecurity and hygiene measures is described, as well as the immune strategy with passive immunization and vaccination trials and the nutritional strategy with the administration of organic and fatty acids, essential oil and plant-derived compound, probiotics, bacteriocins and bacteriophages. © 2015 The Society for Applied Microbiology.

  19. Vulnerability of recently recharged groundwater in principal aquifers of the United States to nitrate contamination

    USGS Publications Warehouse

    Gurdak, Jason J.; Qi, Sharon L.

    2012-01-01

    Recently recharged water (defined here as <60 years old) is generally the most vulnerable part of a groundwater resource to nonpoint-source nitrate contamination. Understanding at the appropriate scale the interactions of natural and anthropogenic controlling factors that influence nitrate occurrence in recently recharged groundwater is critical to support best management and policy decisions that are often made at the aquifer to subaquifer scale. New logistic regression models were developed using data from the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program and National Water Information System for 17 principal aquifers of the U.S. to identify important source, transport, and attenuation factors that control nonpoint source nitrate concentrations greater than relative background levels in recently recharged groundwater and were used to predict the probability of detecting elevated nitrate in areas beyond the sampling network. Results indicate that dissolved oxygen, crops and irrigated cropland, fertilizer application, seasonally high water table, and soil properties that affect infiltration and denitrification are among the most important factors in predicting elevated nitrate concentrations. Important differences in controlling factors and spatial predictions were identified in the principal aquifer and national-scale models and support the conclusion that similar spatial scales are needed between informed groundwater management and model development.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillmer, Kurt T.

    This report focuses on the detection and control of radioactive contamination, which are an integral part of an aggressive ALARA program and provide an indication of the effectiveness of engineering controls and proper work practices in preventing the release of radioactive material. Radioactive contamination, if undetected or not properly controlled, can be spread and contaminate areas, equipment, personnel, and the environment.

  1. Hydrogeologic framework, hydrology, and refined conceptual model of groundwater flow for Coastal Plain aquifers at the Standard Chlorine of Delaware, Inc. Superfund Site, New Castle County, Delaware, 2005-12

    USGS Publications Warehouse

    Brayton, Michael J.; Cruz, Roberto M.; Myers, Luke; Degnan, James R.; Raffensperger, Jeff P.

    2015-01-01

    The regional hydrogeologic framework indicates that the site is underlain by Coastal Plain sediments of the Columbia, Merchantville, and Potomac Formations. Two primary aquifers underlying the site, the Columbia and the upper Potomac, are separated by the Merchantville Formation confining unit. Local groundwater flow in the surficial (Columbia) aquifer is controlled by topography and generally flows northward and discharges to nearby surface water. Regional flow within the Potomac aquifer is towards the southeast, and is strongly influenced by major water withdrawals locally. Previous investigations at the site indicated that contaminants, primarily benzene and chlorinated benzene compounds, were present in the Columbia aquifer in most locations; however, there were only limited detections in the upper Potomac aquifer as of 2004. From 2005 through 2012, the USGS designed a monitoring network, assisted with exploratory drilling, collected data at monitoring wells, conducted geophysical surveys, evaluated water-level responses in wells during pumping of a production well, and evaluated major aquifer withdrawals. Data collected through these efforts were used to refine the local conceptual flow system. The refined conceptual flow system for the site includes: (a) identification of gaps in confining units in the study area, (b) identification and correlation of multiple water-bearing sand intervals within the upper Potomac Formation, (c) connections between groundwater and surface water, (d) connections between shallow and deeper groundwater, (e) new water-level (or potentiometric surface) maps and inferred flow directions, and (f) identification of major local pumping well influences. The implications of the revised conceptual flow system on the occurrence and movement of site contaminants are that the resulting detection of contaminants in the upper Potomac aquifer at specific well locations can be attributed primarily to either advective lateral transport, direct vertical contaminant transport, or a combination of vertical and lateral movement resulting from changes in water withdrawal rates over time.

  2. House hold unit for the treatment of fluoride, iron, arsenic and microorganism contaminated drinking water.

    PubMed

    Dhadge, Vijaykumar L; Medhi, Chitta Ranjan; Changmai, Murchana; Purkait, Mihir Kumar

    2018-05-01

    A first of its kind hybrid electrocoagulation-filtration prototype unit was fabricated for the removal of fluoride, iron, arsenic and microorganisms contaminated drinking water. The unit comprised of 3 chambers, chamber A consisting of an inlet for the water to be treated and an outlet for the treated water along with one block of aluminum electrodes. Chamber B consisted of ceramic membrane filtration assembly at the bottom over a metallic support which filters the flocs so produced in chamber A and chamber C consisting of space to collect the treated water. Operating parameters were maintained as current density of 625 A m -2 and an electrode distance of 0.005 m. Contaminated drinking water containing mixture of fluoride (10 mg L -1 ), iron (25 mg L -1 ), arsenic (200 μg L -1 ) and microorganisms (35 CFU ml -1 ) was used for the experiment. A removal of 98.74%, 95.65%, 93.2% and 100% were obtained for iron, arsenic, fluoride and microorganisms, respectively. The apparatus and method made it possible to efficiently treat contaminated drinking water to produce drinkable water as per WHO specification. By-products obtained from the electrocoagulation bath were analyzed using SEM, EDX and XRD and explained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Optimization Review: Ogallala Ground Water Contamination Superfund Site, Operable Unit 2 (Tip Top Cleaners), Ogallala, Nebraska

    EPA Pesticide Factsheets

    The Ogallala Ground Water Contamination Superfund site was identified in 1989 through municipal well sampling. Tetrachloroethene (PCE), a solvent commonly used in dry cleaner operations, was the primary ground water target chemical of concern (COC) that..

  4. Estimating virus occurrence using Bayesian modeling in multiple drinking water systems of the United States

    EPA Science Inventory

    Drinking water treatment plants rely on purification of contaminated source waters to provide communities with potable water. One group of possible contaminants are enteric viruses. Measurement of viral quantities in environmental water systems are often performed using polymeras...

  5. IMPACTS OF HISTORIC AND CURRENT-USE CHEMICALS IN WESTERN NATIONAL PARKS

    EPA Science Inventory

    The Western Airborne Contaminants Assessment Project (WACAP) is an interagency effort to determine if airborne contaminants such as semi-volatile organic compounds (sacs) and metals

    (e.g. mercury) are impacting National Parks in the western United States. Remote, high elev...

  6. LAND TREATMENT AND THE TOXICITY RESPONSE OF SOIL CONTAMINATED WITH WOOD PRESERVING WASTE

    EPA Science Inventory

    Soils contaminated with wood preserving wastes, including pentachlo-rophenol (PCP) and creosote, are treated at field-scale in an engineered prepared-bed system consisting of two one-acre land treatment units (LTUs). The concentration of selected indicator compounds of treatment ...

  7. COSTS AND ISSUES RELATED TO REMEDIATION OF PETROLEUM-CONTAMINATED SITES

    EPA Science Inventory

    The remediation costs required at sites contaminated with petroleum-derived compounds remains a relevant issue because of the large number of existing underground storage tanks the United States and the presence of benzene, MTBE, and TBA in some drinking water supplies. Cost inf...

  8. PERCHLORATE-CROP INTERACTIONS FROM CONTAMINATED IRRIGATION WATER AND FERTILIZER APPLICATIONS

    EPA Science Inventory

    Perchlorate has contaminated water and soils at several locations in the United States. Perchlorate is water soluble, exceedingly mobile in aqueous systems, and can persist for many decades under typical ground and surface water conditions. Perchlorate is of concern because of un...

  9. Crustal contamination and sulfide immiscibility history of the Permian Huangshannan magmatic Ni-Cu sulfide deposit, East Tianshan, NW China

    NASA Astrophysics Data System (ADS)

    Mao, Ya-Jing; Qin, Ke-Zhang; Tang, Dong-Mei; Feng, Hong-Ye; Xue, Sheng-Chao

    2016-11-01

    The Huangshannan mafic-ultramafic intrusion is a Permian Ni-Cu sulfide-bearing intrusion in the southern margin of the Central Asian Orogenic Belt. The intrusion consists of an ultramafic unit, which is composed of lherzolite and olivine websterite, and a mafic unit, which is composed of olivine gabbronorite, gabbronorite and leuco-gabbronorite. This intrusion was formed by two separate pulses of magma: a more primitive magma for the early ultramafic unit and a more evolved magma for the late mafic unit. U-Pb isotope geochronology of zircon from the mafic unit yields an age of 278 ± 2 Ma. According to its olivine and Cr-rich spinel compositions, the estimated parental magma of lherzolite for the Huangshannan intrusion has 12.4 wt.% MgO, indicating picritic affinity. Fractional crystallization modeling results and the presence of rounded sulfide inclusions in an olivine crystal (Fo 86.7) indicate that sulfide immiscibility was achieved at the beginning of olivine fractionation. Co-magmatic zircon crystals from gabbronorite have a δ18O value close to 6.5‰, which is 1.2‰ higher than the typical mantle value and suggests significant crustal contamination (∼20%). The positive εHf(t) values of co-magmatic zircon (which vary from +9.2 to +15.3) and positive whole rock εNd(t) values (which vary from +4.7 to +7.8) also indicate that the parental magma was derived from a depleted mantle source and contaminated by 5-20% juvenile arc crust and then by ∼5% upper crustal materials. However, modeling results of sulfur content at sulfide saturation reveal that such a large amount of crustal contamination is not sufficient to trigger sulfide saturation in the parental magma, which strongly suggests that external sulfur addition, probably during contamination, has played a critical role in causing sulfide immiscibility. Furthermore, the arc magmatism geochemical signatures of the Huangshannan intrusion, such as significant Nb and Ta depletion relative to La and low Ca contents in olivine, are interpreted as the result of slab-derived fluid modification during previous subduction. We speculate that the contamination of juvenile arc crust may have occurred in the lower crust because of picritic magma underplating and that partial melting in the mantle was triggered by the impingement of a mantle plume or lithosphere delamination in a post-subduction environment.

  10. Hydrogeology and geochemistry of acid mine drainage in ground water in the vicinity of Penn Mine and Camanche Reservoir, Calaveras County, California; first-year summary

    USGS Publications Warehouse

    Hamlin, S.N.; Alpers, Charles N.

    1995-01-01

    Acid drainage from the Penn Mine in Calaveras County, California, has caused contamination of ground water between Mine Run Dam and Camanche Reservoir. The Penn Mine was first developed in the 1860's primarily for copper and later produced lesser amounts of zinc, lead, silver, and gold from steeply dipping massive sulfide lenses in metamorphic rocks. Surface disposal of sulfidic waste rock and tailings from mine operations has produced acidic drainage with pH values between 2.3 and 2.7 and elevated concentrations of sulfate and metals, including copper, zinc, cadmium, iron, and aluminum. During the mine's operation and after its subsequent abandonment in the late 1950's, acid mine drainage flowed down Mine Run into the Mokelumne River. Construction of Camanche Dam in 1963 flooded part of the Mokelumne River adjacent to Penn Mine. Surface-water diversions and unlined impoundments were constructed at Penn Mine in 1979 to reduce runoff from the mine, collect contaminated surface water, and enhance evaporation. Some of the contaminated surface water infiltrates the ground water and flows toward Camanche Reservoir. Ground- water flow in the study area is controlled by the local hydraulic gradient and the hydraulic characteristics of two principal rock types, a Jurassic metavolcanic unit and the underlying Salt Spring slate. The hydraulic gradient is west from Mine Run impoundment toward Camanche Reservoir. The median hydraulic conductivity was about 10 to 50 times higher in the metavolcanic rock (0.1 foot per day) than in the slate (0.002 to 0.01 foot per day); most flow occurs in the metavolcanic rock where hydraulic conductivity is as high as 50 feet per day in two locations. The contact between the two rock units is a fault plane that strikes N20?W, dips 20?NE, and is a likely conduit for ground-water flow, based on down-hole measurements with a heatpulse flowmeter. Analyses of water samples collected during April 1992 provide a comprehensive characterization of ground water below Mine Run Dam at the Penn Mine. Specific conductance of the samples ranged from 1,810 to 18,000 microsiemens per centimeter. pH values of sampled ground water ranged from 3.7 to 7.8. Dissolved constituents in ground water ranged from less than 0.010 to 86 milligrams per liter for copper, from less than 0.010 to 240 milligrams per liter for iron, from less than 0.01 to 250 milligrams per liter for aluminum, and from 0.020 to 600 milligrams per liter for zinc. A contaminated ground-water plume appears to originate in the metavolcanic unit along the north abutment of Mine Run Dam. The plume is characterized by low pH, high concentrations of sulfate and dissolved metals, and enrichment of the heavy stable isotopes of hydrogen and oxygen. Dissolved iron and sulfate correlate positively, suggesting pyrite as the probable source of these elements. The concentrations of some dissolved constituents apparently are controlled by equilibrium with solid mineral phases. Poorly crystalline hydrous ferric oxide and microcrystalline gibbsite are close to saturation in ground water with pH values between 4 and 7.8 and probably control the solubility of Fe3+ and Al3+, respectively. Using a range of bulk hydraulic conductivity values for the metavolcanic unit from the median value (0.1 foot per day) to the highest values (50 feet per day), together with a representative cross-sectional area (3,000 square feet) for the contaminated ground-water plume and a hydraulic gradient of 0.14 from August 1992, the following range in ground-water flow rates is estimated by Darcy's law: 42 to 21,000 cubic feet per day, or 105 to 5x107 gallons per year. Multiplying this estimated range in ground-water flow by representative metal concentrations from the contaminated plume gives the following estimates for annual metal transport to Camanche Reservoir by ground water: 86 to 42,000 pounds of copper; 310 to 150,000 pounds of zinc; and 1.5 to 750 pounds of cadmium. These crude preliminary es

  11. The Exploration Water Recovery System

    NASA Technical Reports Server (NTRS)

    ORourke, Mary Jane E.; Carter, Layne; Holder, Donald W.; Tomes, Kristin M.

    2006-01-01

    The Exploration Water Recovery System is designed towards fulfillment of NASA s Vision for Space Exploration, which will require elevation of existing technologies to higher levels of optimization. This new system, designed for application to the Exploration infrastructure, presents a novel combination of proven air and water purification technologies. The integration of unit operations is modified from that of the current state-of-the-art water recovery system so as to optimize treatment of the various waste water streams, contaminant loads, and flow rates. Optimization is achieved primarily through the removal of volatile organic contaminants from the vapor phase prior to their absorption into the liquid phase. In the current state-of-the-art system, the water vapor in the cabin atmosphere is condensed, and the volatile organic contaminants present in that atmosphere are absorbed into the aqueous phase. Removal of contaminants the5 occurs via catalytic oxidation in the liquid phase. Oxidation kinetics, however, dictate that removal of volatile organic contaminants from the vapor phase can inherently be more efficient than their removal from the aqueous phase. Taking advantage of this efficiency reduces the complexity of the water recovery system. This reduction in system complexity is accompanied by reductions in the weight, volume, power, and resupply requirements of the system. Vapor compression distillation technology is used to treat the urine, condensate, and hygiene waste streams. This contributes to the reduction in resupply, as incorporation of vapor compression distillation technology at this point in the process reduces reliance on the expendable ion exchange and adsorption media used in the current state-of-the-art water recovery system. Other proven technologies that are incorporated into the Exploration Water Recovery System include the Trace Contaminant Control System and the Volatile Removal Assembly.

  12. Prevention of emergency physician migratory contamination in a cluster randomized trial to increase tissue plasminogen activator use in stroke (the INSTINCT trial).

    PubMed

    Weston, Victoria C; Meurer, William J; Frederiksen, Shirley M; Fox, Allison K; Scott, Phillip A

    2014-12-01

    Cluster randomized trials (CRTs) are increasingly used to evaluate quality improvement interventions aimed at health care providers. In trials testing emergency department (ED) interventions, migration of emergency physicians (EPs) between hospitals is an important concern, as contamination may affect both internal and external validity. We hypothesized that geographically isolating EDs would prevent migratory contamination in a CRT designed to increase ED delivery of tissue plasminogen activator (tPA) in stroke (the INSTINCT trial). INSTINCT was a prospective, cluster randomized, controlled trial. Twenty-four Michigan community hospitals were randomly selected in matched pairs for study. Contamination was defined at the cluster level, with substantial contamination defined a priori as greater than 10% of EPs affected. Nonadherence, total crossover (contamination+nonadherence), migration distance, and characteristics were determined. Three hundred seven EPs were identified at all sites. Overall, 7 (2.3%) changed study sites. One moved between control sites, leaving 6 (2.0%) total crossovers. Of these, 2 (0.7%) moved from intervention to control (contamination); and 4 (1.3%) moved from control to intervention (nonadherence). Contamination was observed in 2 of 12 control sites, with 17% and 9% contamination of the total site EP workforce at follow-up, respectively. Average migration distance was 42 miles for all EPs moving in the study and 35 miles for EPs moving from intervention to control sites. The mobile nature of EPs should be considered in the design of quality improvement CRTs. Increased reporting of contamination in CRTs is encouraged to clarify thresholds and facilitate CRT design. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Technical/ administrative options for managing tritium MCL exceedances in P-area groundwater and Steel Creek

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, J.

    2017-04-01

    This white paper was requested by the Core Team (United States Department of Energy [USDOE], United States Environmental Protection Agency [USEPA], and South Carolina Department of Health and Environmental Control [SCDHEC]) at the P-Area Groundwater (PAGW) Operable Unit (OU) Scoping Meeting held in January 2017 to discuss recent data and potential alternatives in support of a focused Corrective Measures Study/Feasibility Study (CMS/FS). This white paper presents an overview of the problem, and a range of technical and administrative options for addressing the tritium contamination in groundwater and Steel Creek. As tritium cannot be treated practicably, alternatives are limited to mediamore » transfer, containment and natural attenuation principally relying on radioactive decay. Using other groundwater OU decisions involving tritium as precedent, Savannah River Nuclear Solutions (SRNS) recommends that final tritium alternatives be evaluated in a CMS/FS, understanding that the likely preferred remedy will include natural attenuation with land use controls (LUCs). This is based on the inability to significantly reduce tritium impact to Steel Creek using an engineered solution as compared to natural attenuation. The timing of this evaluation could be conducted concurrently with the final remedy evaluation for volatile organic compounds (VOCs).« less

  14. 40 CFR 279.44 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the... CFCs that have been mixed with used oil from sources other than refrigeration units. (d) Record...

  15. 40 CFR 279.44 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the... CFCs that have been mixed with used oil from sources other than refrigeration units. (d) Record...

  16. 40 CFR 279.44 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the... CFCs that have been mixed with used oil from sources other than refrigeration units. (d) Record...

  17. 40 CFR 279.44 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the... CFCs that have been mixed with used oil from sources other than refrigeration units. (d) Record...

  18. 40 CFR 279.44 - Rebuttable presumption for used oil.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the... CFCs that have been mixed with used oil from sources other than refrigeration units. (d) Record...

  19. Hydrogeologic conditions and saline-water intrusion, Cape Coral, Florida, 1978-81

    USGS Publications Warehouse

    Fitzpatrick, D.J.

    1986-01-01

    The upper limestone unit of the intermediate aquifer system, locally called the upper Hawthorn aquifer, is the principal source of freshwater for Cape Coral, Florida. The aquifer has been contaminated with saline water by downward intrusion from the surficial aquifer system and by upward intrusion from the Floridan aquifer system. Much of the intrusion has occurred through open wellbores where steel casings are short or where casings have collapsed because of corrosion. Saline-water contamination of the upper limestone unit due to downward intrusion from the surficial aquifer is most severe in the southern and eastern parts of Cape Coral; contamination due to upward intrusion has occurred in many areas throughout Cape Coral. Intrusion is amplified in areas of heavy water withdrawals and large water-level declines. (USGS)

  20. Impact of revising the National Nosocomial Infection Surveillance System definition for catheter-related bloodstream infection in ICU: reproducibility of the National Healthcare Safety Network case definition in an Australian cohort of infection control professionals.

    PubMed

    Worth, Leon J; Brett, Judy; Bull, Ann L; McBryde, Emma S; Russo, Philip L; Richards, Michael J

    2009-10-01

    Effective and comparable surveillance for central venous catheter-related bloodstream infections (CLABSIs) in the intensive care unit requires a reproducible case definition that can be readily applied by infection control professionals. Using a questionnaire containing clinical cases, reproducibility of the National Nosocomial Infection Surveillance System (NNIS) surveillance definition for CLABSI was assessed in an Australian cohort of infection control professionals participating in the Victorian Hospital Acquired Infection Surveillance System (VICNISS). The same questionnaire was then used to evaluate the reproducibility of the National Healthcare Safety Network (NHSN) surveillance definition for CLABSI. Target hospitals were defined as large metropolitan (1A) or other large hospitals (non-1A), according to the Victorian Department of Human Services. Questionnaire responses of Centers for Disease Control and Prevention NHSN surveillance experts were used as gold standard comparator. Eighteen of 21 eligible VICNISS centers participated in the survey. Overall concordance with the gold standard was 57.1%, and agreement was highest for 1A hospitals (60.6%). The proportion of congruently classified cases varied according to NNIS criteria: criterion 1 (recognized pathogen), 52.8%; criterion 2a (skin contaminant in 2 or more blood cultures), 83.3%; criterion 2b (skin contaminant in 1 blood culture and appropriate antimicrobial therapy instituted), 58.3%; non-CLABSI cases, 51.4%. When survey questions regarding identification of cases of CLABSI criterion 2b were removed (consistent with the current NHSN definition), overall percentage concordance increased to 62.5% (72.2% for 1A centers). Further educational interventions are required to improve the discrimination of primary and secondary causes of bloodstream infection in Victorian intensive care units. Although reproducibility of the CLABSI case definition is relatively poor, adoption of the revised NHSN definition for CLABSI is likely to improve the concordance of Victorian data with international centers.

Top