Xu, D Z; Deitch, E A; Sittig, K; Qi, L; McDonald, J C
1988-01-01
Mononuclear cells isolated by density gradient centrifugation from the peripheral blood of burn patients, but not healthy volunteers, are contaminated with large numbers of nonmononuclear cells. These contaminating leukocytes could cause artifactual alterations in standard in vitro tests of lymphocyte function. Thus, we compared the in vitro blastogenic response of density gradient purified leukocytes and T-cell purified lymphocytes from 13 burn patients to mitogenic (PHA) and antigenic stimuli. The mitogenic and antigenic response of the patients' density gradient purified leukocytes were impaired compared to healthy volunteers (p less than 0.01). However, when the contaminating nonlymphocytes were removed, the patients' cells responded normally to both stimuli. Thus, density gradient purified mononuclear cells from burn patients are contaminated by leukocytes that are not phenotypically or functionally lymphocytes. Since the lymphocytes from burn patients respond normally to PHA and alloantigens after the contaminating nonlymphocyte cell population has been removed, it appears that in vitro assays of lymphocyte function using density gradient purified leukocytes may give spurious results. PMID:2973771
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steigies, C. T.; Barjatya, A.
Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determined from the measurements and correct plasma parameters can then be determined. In this paper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seenmore » in the data. Even though the contamination is not evident from the measurements, it does affect the plasma density fluctuation spectrum as measured by the fixed-bias Langmuir probe. We model the contamination as a simple resistor-capacitor circuit between the probe surface and the plasma. We find that measurements of small scale plasma fluctuations (meter to sub-meter scale) along a rocket trajectory are not affected, but the measured amplitude of large scale plasma density variation (tens of meters or larger) is attenuated. From the model calculations, we determine amplitude and cross-over frequency of the contamination effect on fixed-bias probes for different contamination parameters. The model results also show that a fixed bias probe operating in the ion-saturation region is affected less by contamination as compared to a fixed bias probe operating in the electron saturation region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reece, Charles E.; Ciancio, Elizabeth J.; Keyes, Katharine A.
2009-11-01
Particulate contamination on the surface of SRF cavities limits their performance via the enhanced generation of field-emitted electrons. Considerable efforts are expended to actively clean and avoid such contamination on niobium surfaces. The protocols in active use have been developed via feedback from cavity testing. This approach has the risk of over-conservatively ratcheting an ever increasing complexity of methods tied to particular circumstances. A complementary and perhaps helpful approach is to quantitatively assess the effectiveness of candidate methods at removing intentional representative particulate contamination. Toward this end, we developed a standardized contamination protocol using water suspensions of Nb{sub 2}O{sub 5}more » and SS 316 powders applied to BCP’d surfaces of standardized niobium samples yielding particle densities of order 200 particles/mm{sup 2}. From these starting conditions, controlled application of high pressure water rinse, ultrasonic cleaning, or CO{sub 2} snow jet cleaning was applied and the resulting surfaces examined via SEM/scanning EDS with particle recognition software. Results of initial parametric variations of each will be reported.« less
ACOUSTIC TECHNIQUES FOR THE MAPPING OF THE DISTRIBUTION OF CONTAMINATED SEDIMENTS
An overview of the last 30 years of analytical research into the acoustic properties of harbor marine sediments has allowed the extension of the original work of Hamilton (1970) into a production system for classifying the density and bulk physical properties of standard marine s...
Ham, Young-Sik; Kobori, Hiromi; Takasago, Masahisa
2009-05-01
The indicator bacteria (standard plate count, total coliform, and fecal coliform bacteria) concentrations have been investigated using six ambient habitats (population density, percent sewer penetration, stream flow rate (m(3)/sec), percent residential area, percent forest area and percent agricultural area) in the Tama River basin in Tokyo, Japan during June 2003 to January 2005. The downstream and tributary Tama River showed higher concentrations of TC and FC bacteria than the upstream waters, which exceeded an environmental quality standard for rivers and a bathing water quality criterion. It was estimated that combined sewer overflow (CSO) and stormwater effluents contributed -4-23% to the indicator bacteria concentrations of the Tama River. The results of multiple regression analyses show that the indicator bacteria concentrations of Tama River basin are significantly affected by population density. It is concluded that the Tama River received a significant bacterial contamination load originating from the anthropogenic source.
NASA Astrophysics Data System (ADS)
Pan, Wenyong; Geng, Yu; Innanen, Kristopher A.
2018-05-01
The problem of inverting for multiple physical parameters in the subsurface using seismic full-waveform inversion (FWI) is complicated by interparameter trade-off arising from inherent ambiguities between different physical parameters. Parameter resolution is often characterized using scattering radiation patterns, but these neglect some important aspects of interparameter trade-off. More general analysis and mitigation of interparameter trade-off in isotropic-elastic FWI is possible through judiciously chosen multiparameter Hessian matrix-vector products. We show that products of multiparameter Hessian off-diagonal blocks with model perturbation vectors, referred to as interparameter contamination kernels, are central to the approach. We apply the multiparameter Hessian to various vectors designed to provide information regarding the strengths and characteristics of interparameter contamination, both locally and within the whole volume. With numerical experiments, we observe that S-wave velocity perturbations introduce strong contaminations into density and phase-reversed contaminations into P-wave velocity, but themselves experience only limited contaminations from other parameters. Based on these findings, we introduce a novel strategy to mitigate the influence of interparameter trade-off with approximate contamination kernels. Furthermore, we recommend that the local spatial and interparameter trade-off of the inverted models be quantified using extended multiparameter point spread functions (EMPSFs) obtained with pre-conditioned conjugate-gradient algorithm. Compared to traditional point spread functions, the EMPSFs appear to provide more accurate measurements for resolution analysis, by de-blurring the estimations, scaling magnitudes and mitigating interparameter contamination. Approximate eigenvalue volumes constructed with stochastic probing approach are proposed to evaluate the resolution of the inverted models within the whole model. With a synthetic Marmousi model example and a land seismic field data set from Hussar, Alberta, Canada, we confirm that the new inversion strategy suppresses the interparameter contamination effectively and provides more reliable density estimations in isotropic-elastic FWI as compared to standard simultaneous inversion approach.
NASA Astrophysics Data System (ADS)
Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya
To rationally judge the necessity of the contamination screening measurements required in the decontamination work regulations, a field study of the surface contamination density on the clothing of the workers engaged in decontamination operations was performed. The clothing and footwear of 20 workers was analyzed by high-purity germanium (HPGe) gamma-ray spectroscopy. The maximum radiocesium activities (134Cs + 137Cs) observed were 3600, 1300, and 2100 Bq for the work clothing, gloves, and boots, respectively, and the derived surface contamination densities were below the regulatory limit of 40 Bq/cm2. The results of this field study suggest that the upper bounds of the surface contamination density on the work clothing, gloves, and boots are predictable from the maximum soil loading density on the surface of clothing and footwear and the radioactivity concentration in soil at the site.
Herzog, Mark; Ackerman, Joshua T.; Eagles-Smith, Collin A.; Hartman, Christopher
2016-01-01
In egg contaminant studies, it is necessary to calculate egg contaminant concentrations on a fresh wet weight basis and this requires accurate estimates of egg density and egg volume. We show that the inclusion or exclusion of the eggshell can influence egg contaminant concentrations, and we provide estimates of egg density (both with and without the eggshell) and egg-shape coefficients (used to estimate egg volume from egg morphometrics) for American avocet (Recurvirostra americana), black-necked stilt (Himantopus mexicanus), and Forster’s tern (Sterna forsteri). Egg densities (g/cm3) estimated for whole eggs (1.056 ± 0.003) were higher than egg densities estimated for egg contents (1.024 ± 0.001), and were 1.059 ± 0.001 and 1.025 ± 0.001 for avocets, 1.056 ± 0.001 and 1.023 ± 0.001 for stilts, and 1.053 ± 0.002 and 1.025 ± 0.002 for terns. The egg-shape coefficients for egg volume (K v ) and egg mass (K w ) also differed depending on whether the eggshell was included (K v = 0.491 ± 0.001; K w = 0.518 ± 0.001) or excluded (K v = 0.493 ± 0.001; K w = 0.505 ± 0.001), and varied among species. Although egg contaminant concentrations are rarely meant to include the eggshell, we show that the typical inclusion of the eggshell in egg density and egg volume estimates results in egg contaminant concentrations being underestimated by 6–13 %. Our results demonstrate that the inclusion of the eggshell significantly influences estimates of egg density, egg volume, and fresh egg mass, which leads to egg contaminant concentrations that are biased low. We suggest that egg contaminant concentrations be calculated on a fresh wet weight basis using only internal egg-content densities, volumes, and masses appropriate for the species. For the three waterbirds in our study, these corrected coefficients are 1.024 ± 0.001 for egg density, 0.493 ± 0.001 for K v , and 0.505 ± 0.001 for K w .
Selçuk, Caferi Tayyar; Durgun, Mustafa; Ozalp, Burhan; Tekin, Alicem; Tekin, Recep; Akçay, Cemal; Alabalık, Ulaş
2012-12-01
In this study, our aim is to compare the efficacy of different topical antibacterial agents in a rat model contaminated with a multi drug resistant (MDR) standard Acinetobacter baumannii strain. The study was carried out on 40 Sprague-Dawley rats of 250-300 g each. For the purposes of this study, the rats were divided into 5 groups, with 8 rats in each group: Group 1 control; Group 2 silver sulfadiazine; Group 3 mupirocin; Group 4 Acticoat group; and Group 5 octenidine dihydrochloride group. Following to the formation of the full-thickness burn areas in rats, the MDR A. baumannii standard strain was inoculated into the burned area. The rats in all the groups were sacrificed at the end of the 10th day and subjected to histopathological and microbiological evaluation. In the histopathological evaluation, the lowest inflammatory cell response and bacterial density in the eschar and muscle tissues were observed in the Acticoat group. While these results were found to be statistically significant compared to the silver sulfadiazine group, only the bacterial density in the muscle tissue was found as significant in comparison to the mupirocin and octenidine groups. In the microbiological evaluation, the lowest growth in the muscle tissue culture among all the groups was observed in the Acticoat group. The growth in the eschar tissue culture was significantly lower in the Acticoat and octenidine groups in comparison to the silver sulfadiazine group. At the end of the study, it has been observed that Acticoat was effective both in eschar and muscle, while octenidine was effective in eschar tissues in a rat burn model contaminated with MDR A. baumannii. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Microbiological quality of indoor air in university libraries.
Hayleeyesus, Samuel Fekadu; Manaye, Abayneh Melaku
2014-05-01
To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control. The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods. The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi. The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.
Gregory-Eaves, Irene; Demers, J Marc J; Kimpe, Lynda; Krümmel, Eva M; Macdonald, Robie W; Finney, Bruce P; Blais, Jules M
2007-06-01
Many have demonstrated that anadromous Pacific salmon are significant vectors of nutrients from the ocean to freshwaters. Recently. however, it has been recognized that salmon spawners also input significant quantities of contaminants. The objectives of this paper are to delineate the extent to which salmon-derived nutrients are integrated into the freshwater food web using delta(15)N and delta(13)C and to assess the influence of the salmon pathway in the accumulation of contaminants in rainbow trout (Oncorhynchus mykiss). We found that the delta(15)N and delta(13)C of food web components were related positively and significantly to sockeye salmon (Oncorhynchus nerka) spawner density. Contaminant concentrations in rainbow trout also positively and significantly were related to sockeye salmon spawner density. These data suggest that the anadromous salmon nutrient and contaminant pathways are related and significantly impact the contaminant burden of resident fish.
Gabard-Durnam, Laurel J; Mendez Leal, Adriana S; Wilkinson, Carol L; Levin, April R
2018-01-01
Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe.
Gabard-Durnam, Laurel J.; Mendez Leal, Adriana S.; Wilkinson, Carol L.; Levin, April R.
2018-01-01
Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe. PMID:29535597
NASA Astrophysics Data System (ADS)
Varanasi, Rao; Mesawich, Michael; Connor, Patrick; Johnson, Lawrence
2017-03-01
Two versions of a specific 2nm rated filter containing filtration medium and all other components produced from high density polyethylene (HDPE), one subjected to standard cleaning, the other to specialized ultra-cleaning, were evaluated in terms of their cleanliness characteristics, and also defectivity of wafers processed with photoresist filtered through each. With respect to inherent cleanliness, the ultraclean version exhibited a 70% reduction in total metal extractables and 90% reduction in organics extractables compared to the standard clean version. In terms of particulate cleanliness, the ultraclean version achieved stability of effluent particles 30nm and larger in about half the time required by the standard clean version, also exhibiting effluent levels at stability almost 90% lower. In evaluating defectivity of blanket wafers processed with photoresist filtered through either version, initial defect density while using the ultraclean version was about half that observed when the standard clean version was in service, with defectivity also falling more rapidly during subsequent usage of the ultraclean version compared to the standard clean version. Similar behavior was observed for patterned wafers, where the enhanced defect reduction was primarily of bridging defects. The filter evaluation and actual process-oriented results demonstrate the extreme value in using filtration designed possessing the optimal intrinsic characteristics, but with further improvements possible through enhanced cleaning processes
Herzog, Mark P; Ackerman, Joshua T; Eagles-Smith, Collin A; Hartman, C Alex
2016-05-01
In egg contaminant studies, it is necessary to calculate egg contaminant concentrations on a fresh wet weight basis and this requires accurate estimates of egg density and egg volume. We show that the inclusion or exclusion of the eggshell can influence egg contaminant concentrations, and we provide estimates of egg density (both with and without the eggshell) and egg-shape coefficients (used to estimate egg volume from egg morphometrics) for American avocet (Recurvirostra americana), black-necked stilt (Himantopus mexicanus), and Forster's tern (Sterna forsteri). Egg densities (g/cm(3)) estimated for whole eggs (1.056 ± 0.003) were higher than egg densities estimated for egg contents (1.024 ± 0.001), and were 1.059 ± 0.001 and 1.025 ± 0.001 for avocets, 1.056 ± 0.001 and 1.023 ± 0.001 for stilts, and 1.053 ± 0.002 and 1.025 ± 0.002 for terns. The egg-shape coefficients for egg volume (K v ) and egg mass (K w ) also differed depending on whether the eggshell was included (K v = 0.491 ± 0.001; K w = 0.518 ± 0.001) or excluded (K v = 0.493 ± 0.001; K w = 0.505 ± 0.001), and varied among species. Although egg contaminant concentrations are rarely meant to include the eggshell, we show that the typical inclusion of the eggshell in egg density and egg volume estimates results in egg contaminant concentrations being underestimated by 6-13 %. Our results demonstrate that the inclusion of the eggshell significantly influences estimates of egg density, egg volume, and fresh egg mass, which leads to egg contaminant concentrations that are biased low. We suggest that egg contaminant concentrations be calculated on a fresh wet weight basis using only internal egg-content densities, volumes, and masses appropriate for the species. For the three waterbirds in our study, these corrected coefficients are 1.024 ± 0.001 for egg density, 0.493 ± 0.001 for K v , and 0.505 ± 0.001 for K w .
Petti, S; Messano, G A
2016-05-01
Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (P<0.01). Log MRSA density reduction attributable to PCD was 1.16logcfu/cm(2), corresponding to 93% reduction of the baseline MRSA contamination. The disinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (<1cfu/cm(2)), but required 3h of exposure to photocatalysis. Thus, PCD could be considered for non-clinical surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarpellini, D.; Paoloni, S.; Medaglia, P.G.
Highlights: • ZnO nanorods were grown on Au and Ag films in aqueous solution by galvanic effect. • The method is prone to metal contamination which can influence the ZnO properties. • Iron doping improves the lattice matching between ZnO and the substrate. • Energy levels of point defects are lowered and the light emission is red-shifted. • Galvanic-induced nucleation starts and proceeds continuously during the growth. - Abstract: Dense arrays of vertically aligned ZnO nanorods have been grown onto either silver or gold seedless substrates trough a simple hydrothermal method by exploiting the galvanic effect between the substrate andmore » metallic parts. The nanorods exhibit larger bases and more defined hexagonal shapes, in comparison with standard non-galvanic wet-chemistry synthesis. X-ray diffraction (XRD) shows that the iron contamination, associated with the galvanic contact, significantly improves the in-plane compatibility of ZnO with the Au and Ag cubic lattice. Photoluminescence (PL) measurements indicate that the contamination does not affect the number density of localized defects, but lowers their energy levels uniformly; differently, the band-edge emission is not altered appreciably. Finally, we have found that the ZnO hetero-nucleation by galvanic effect initiates at different times in different sites of the substrate area. Our results can be useful for the fabrication of high performance piezonanodevices comprising high-density metal-to-ZnO nanoscaled junctions without intermediate polycrystalline layers.« less
NASA Astrophysics Data System (ADS)
Rouillon, M.; Taylor, M. P.; Dong, C.
2016-12-01
This research assesses the advantages of integrating field portable X-ray Fluorescence (pXRF) technology for reducing the risk and increase confidence of decision making for metal-contaminated site assessments. Metal-contaminated sites are often highly heterogeneous and require a high sampling density to accurately characterize the distribution and concentration of contaminants. The current regulatory assessment approaches rely on a small number of samples processed using standard wet-chemistry methods. In New South Wales (NSW), Australia, the current notification trigger for characterizing metal-contaminated sites require the upper 95% confidence interval of the site mean to equal or exceed the relevant guidelines. The method's low `minimum' sampling requirements can misclassify sites due to the heterogeneous nature of soil contamination, leading to inaccurate decision making. To address this issue, we propose integrating infield pXRF analysis with the established sampling method to overcome sampling limitations. This approach increases the minimum sampling resolution and reduces the 95% CI of the site mean. Infield pXRF analysis at contamination hotspots enhances sample resolution efficiently and without the need to return to the site. In this study, the current and proposed pXRF site assessment methods are compared at five heterogeneous metal-contaminated sites by analysing the spatial distribution of contaminants, 95% confidence intervals of site means, and the sampling and analysis uncertainty associated with each method. Finally, an analysis of costs associated with both the current and proposed methods is presented to demonstrate the advantages of incorporating pXRF into metal-contaminated site assessments. The data shows that pXRF integrated site assessments allows for faster, cost-efficient, characterisation of metal-contaminated sites with greater confidence for decision making.
Ogan, M T
1989-12-01
The possible relationship between high numbers of fecal coliforms (FCs), fecal streptococci (FS), standard plate count (SPCs) and well characteristics viz: well depth, water column, temperature, pH and non-filterable residue in 25 rural community wells in the Port Harcourt region, Nigeria, was studied. Zonal differences in residue level, well depth and fecal indicator bacteria were observed; these parameters were lowest in an area of high population density (slum) reclaimed from and adjacent to mangrove forests. Although some wells were covered and/or walled to protect them from surface runoff contamination, FCs and FS were recovered from all, except three, in numbers (log10 per 100 mL) ranging respectively from 0.40-3.79 and 0.70-3.44. The FC:FS ratio was less than 1.0 in 8 and greater than 1.0 in 14 samples. Well depth correlated with FCs (p = 0.01; r = 0.5684), FS (p = 0.001; r = 0.6423), pH (p = 0.0001; r = 0.5981); FCs and FS correlated significantly (p = 0.01; r = 0.4948). SPCs did not correlate significantly with FCs, FS and the well and water characteristics. Simultaneous analysis of samples by the Membrane-filtration (MF) and Most Probable Number (MPN) methods recovered mean FC counts in the decreasing sequence: Standard-MPN----Anaerobic----Aerobic MF----Direct-MPN. The underground water table is most probably contaminated via large numbers of soakaway pits and similar conveniences. Downward movement of contaminant from the shallow conveniences into deeper water tables may explain the well depth: indicator bacteria correlation.
RF plasma cleaning of silicon substrates with high-density polyethylene contamination
NASA Astrophysics Data System (ADS)
Cagomoc, Charisse Marie D.; De Leon, Mark Jeffry D.; Ebuen, Anna Sophia M.; Gilos, Marlo Nicole R.; Vasquez, Magdaleno R., Jr.
2018-01-01
Upon contact with a polymeric material, microparticles from the polymer may adhere to a silicon (Si) substrate during device processing. The adhesion contaminates the surface and, in turn, leads to defects in the fabricated Si-based microelectronic devices. In this study, Si substrates with artificially induced high-density polyethylene (HDPE) contamination was exposed to 13.56 MHz radio frequency (RF) plasma utilizing argon and oxygen gas admixtures at a power density of 5.6 W/cm2 and a working pressure of 110 Pa for up to 6 min of treatment. Optical microscopy studies revealed the removal of up to 74% of the polymer contamination upon plasma exposure. Surface free energy (SFE) increased owing to the removal of contaminants as well as the formation of polar groups on the Si surface after plasma treatment. Atomic force microscopy scans showed a decrease in surface roughness from 12.25 nm for contaminated samples to 0.77 nm after plasma cleaning. The smoothening effect can be attributed to the removal of HDPE particles from the surface. In addition, scanning electron microscope images showed that there was a decrease in the amount of HDPE contaminants adhering onto the surface after plasma exposure.
NASA Astrophysics Data System (ADS)
Zhai, Yunfeng; St-Pierre, Jean
2017-12-01
Realistically, proton exchange membrane fuel cells (PEMFCs) are operated under varying operating conditions that potentially impact the acetylene contamination reactions. In this paper, the effects of the cell operating conditions on the acetylene contamination in PEMFCs are investigated under different current densities and temperatures with different acetylene concentrations in the cathode. Electrochemical impedance spectroscopy is applied during the constant-current operation to analyze the impacts of the operating conditions on the acetylene electrochemical reactions. The experimental results indicate that higher acetylene concentrations, higher current densities and lower cell temperatures decrease the cell performance more. In particular, cathode poisoning becomes more severe at medium cell current densities. The cell cathode potentials at such current densities are not sufficient to completely oxidize the intermediate or sufficiently low to completely reduce the adsorbed acetylene. Based on these investigations, the possible condition-dependent limitations of the acetylene concentration and cell operating voltage are proposed for insight into the acetylene contamination mitigation stratagem. Regarding the barrier conditions, the acetylene reactions change abruptly, and adjusting the cell operation parameters to change the acetylene adsorbate and intermediate accumulation conditions to induce complete oxidation or reduction conditions may mitigate the severe acetylene contamination effects on PEMFCs.
Drinking Water Contaminants -- Standards and Regulations
... Labs and Research Centers Contact Us Share Drinking Water Contaminants – Standards and Regulations EPA identifies contaminants to regulate in drinking water to protect public health. The Agency sets regulatory ...
Transport of dense pollutants: nonlinear random walk modeling and experimental validation
NASA Astrophysics Data System (ADS)
Zoia, A.; Latrille, C.; Cartalade, A.
2009-04-01
Non-Fickian transport is widespread in radionuclides and/or chemical species migration, which is key in the context of nuclear waste disposal: the contaminant spread might grow nonlinearly in time, the resulting concentration profiles displaying a non-Gaussian behavior [1]. An important source of such anomalous features is the collective motion of pollutants due to reciprocal interactions. Migration of concentrated particles usually displays these nonlinear phenomena: indeed, the motion of a single contaminant parcel depends on the density of the fluid nearby, which in turn is affected by the number of such parcels at a given position. High density gradients are encountered when either the contaminant itself is strongly concentrated at the source, or the plume flows through regions that are rich in salt; this latter case might become a major concern for radioactive waste disposal near salt domes: even modest density differences with respect to the resident fluid might sensibly affect the contaminant dynamics [2-4]. We propose a model for the concentration-dependent dynamics of a dense contaminant plume through a porous material and we explore its qualitative behavior by resorting to Monte Carlo simulation. We start by considering a vertical column filled with fully saturated and uniformly packed sand. The injected contaminant can be conceptually represented as an ensemble of fluid parcels, whose force balance is then rewritten in nonlinear stochastic Langevin form. This equation can be directly integrated by particle tracking simulation. Nonlinearities arise from the fact that both advection and dispersion of the contaminant plume are concentration-dependent, so that microscopic particles trajectories are correlated via the density field: flow and transport are coupled. The strength of nonlinear terms is controlled by a parameter ε that is proportional to the molar concentration Cmol [mol/L] of the injected solution. When Cmol is weak, ε â 0 and standard Fickian transport with uncorrelated particles paths is recovered. We have tested the proposed random walk model on experimental measurements of dense contaminant transport obtained with the BEETI experimental device, a dichromatic X-ray source coupled with a NaI detector [5] This setup allows quantitatively assessing the contaminant concentration câ(t) inside a vertical 80 cm column (as a function of time), at various sections â. The injected contaminant is KI and the column is filled with homogeneously mixed Fontainebleau sand. As a salient feature, contaminant profiles are sensibly skewed (depending on the flow direction) and therefore non-Gaussian. Monte Carlo estimates of concentration profiles and temporal moments have been computed and a good agreement is found between simulation results and experimental data, for both downwards and upwards injection, at various flow regimes and molar concentrations. The proposed random walk model is admittedly simple, since the full spectrum of interactions that actually take place between the velocity and density fields [2-4] has been condensed in a single nonlinear coupling at the scale of particles trajectories. Yet, despite its simplicity, it compares well to the set of dense contaminant transport measurements. Finally, the random walk approach has been rephrased in terms of a more general nonlinear master equation [6], thus providing a link with the Continuous Time Random Walk (CTRW) formalism [1,7]. The CTRW framework can be used to deal with heterogenous and/or unsaturated porous media and this allows extending our model, so to make predictions about pollutants behavior in such complex materials. References [1] B. Berkowitz, A. Cortis, M. Dentz, and H. Scher, Rev. Geophys. 44, RG2003 (2006). [2] S. M. Hassanizadeh and A. Leijnse, Adv. Water Resour. 18, 203 (1995). [3] C. T. Simmons, T. R. Fenstemaker, and J. M. Sharp Jr., J. Contam. Hydrology 52, 245 (2001). [4] H.-J. G. Diersch and O. Kolditz, Adv. Water Resour. 25, 899 (2002). [5] P. H. Chavanis, Eur. Phys. J. B 62, 179 (2008). [6] A. Cartalade, C. Latrille, G. Lapasset, D. Chambellan, and S. Cadalen, TR DM2S/SFME/MTMS/07-018/A (2007). [7] H. Scher, G. Margolin, and B. Berkowitz, Chem. Phys. 284, 349 (2002).
Code of Federal Regulations, 2012 CFR
2012-01-01
... fumigation of cotton and covers (other than high density cotton free of surface contamination) will be... only lint, linters, or waste, and the bales of which are compressed to a density of 28 or more pounds per cubic foot and are free of surface contamination. (b) An inspector may authorize the substitution...
Code of Federal Regulations, 2013 CFR
2013-01-01
... fumigation of cotton and covers (other than high density cotton free of surface contamination) will be... only lint, linters, or waste, and the bales of which are compressed to a density of 28 or more pounds per cubic foot and are free of surface contamination. (b) An inspector may authorize the substitution...
Code of Federal Regulations, 2014 CFR
2014-01-01
... fumigation of cotton and covers (other than high density cotton free of surface contamination) will be... only lint, linters, or waste, and the bales of which are compressed to a density of 28 or more pounds per cubic foot and are free of surface contamination. (b) An inspector may authorize the substitution...
Sampling methods for recovery of human enteric viruses from environmental surfaces.
Turnage, Nicole L; Gibson, Kristen E
2017-10-01
Acute gastroenteritis causes the second highest infectious disease burden worldwide. Human enteric viruses have been identified as leading causative agents of acute gastroenteritis as well as foodborne illnesses in the U.S. and are generally transmitted by fecal-oral contamination. There is growing evidence of transmission occurring via contaminated fomite including food contact surfaces. Additionally, human enteric viruses have been shown to remain infectious on fomites over prolonged periods of time. To better understand viral persistence, there is a need for more studies to investigate this phenomenon. Therefore, optimization of surface sampling methods is essential to aid in understanding environmental contamination to ensure proper preventative measures are being applied. In general, surface sampling studies are limited and highly variable among recovery efficiencies and research parameters used (e.g., virus type/density, surface type, elution buffers, tools). This review aims to discuss the various factors impacting surface sampling of viruses from fomites and to explore how researchers could move towards a more sensitive and standard sampling method. Copyright © 2017 Elsevier B.V. All rights reserved.
Fulton, M; Key, P; Wirth, E; Leight, A K; Daugomah, J; Bearden, D; Sivertsen, S; Scott, G
2006-10-01
Toxic contaminants may enter estuarine ecosystems through a variety of pathways. When sediment contaminant levels become sufficiently high, they may impact resident biota. One approach to predict sediment-associated toxicity in estuarine ecosystems involves the use of sediment quality guidelines (ERMs, ERLs) and site-specific contaminant chemistry while a second approach utilizes site-specific ecological sampling to assess impacts at the population or community level. The goal of this study was to utilize an integrated approach including chemical contaminant analysis, sediment quality guidelines and grass shrimp population monitoring to evaluate the impact of contaminants from industrial sources. Three impacted sites and one reference site were selected for study. Grass shrimp populations were sampled using a push-netting approach. Sediment samples were collected at each site and analyzed for metals, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and pesticides. Contaminant levels were then compared to sediment quality guidelines. In general, grass shrimp population densities at the sites decreased as the ERM quotients increased. Grass shrimp densities were significantly reduced at the impacted site that had an ERM exceedance for chromium and the highest Mean ERM quotient. Regression analysis indicated that sediment chromium concentrations were negatively correlated with grass shrimp density. Grass shrimp size was reduced at two sites with intermediate levels of contamination. These findings support the use of both sediment quality guidelines and site-specific population monitoring to evaluate the impacts of sediment-associated contaminants in estuarine systems.
NASA Astrophysics Data System (ADS)
Murshid, N.; Kamil, N. A. F. M.; Kadir, A. A.
2018-04-01
Petroleum sludge is one of the major solid wastes generated in the petroleum industry. Generally, there are numbers of heavy metals in petroleum sludge and one treatment that is gaining prominence to treat a variety of mixed organic and inorganic waste is solidification/stabilization (S/S) method. The treatment protects human health and the environment by immobilizing contaminants within the treated material and prevents migration of the contaminants. In this study, solidification/stabilization (S/S) method has been used to treat the petroleum sludge. The comparison of hydration days, namely, 7th and 28th days in these cement-based waste materials were studied by using Synthetic Precipitate Leaching Procedure (SPLP). The results were compared to the United States Environmental Protection Agency (USEPA) standards. The results for leaching test concluded that less percentage OPC gave maximum concentration of heavy metals leaching due to deficient in Calcium Oxide (CaO), which is can caused weak solidification in the mixture. Physical and mechanical properties conducted such as compressive strength and density test. From the results, it shows addition up to of 30percentage PS give results which comply with minimum landfill dispose limit. The results shows correlation between strength and density are strong regression coefficient of 82.7%. In conclusion, S/S method can be alternative disposal method for PS in the same time complies with standard for minimum landfill disposal limit. The results for leaching test concluded the less OPC percentage gave maximum concentration of heavy metals leaching.
Microplastic contamination in Lake Winnipeg, Canada.
Anderson, Philip J; Warrack, Sarah; Langen, Victoria; Challis, Jonathan K; Hanson, Mark L; Rennie, Michael D
2017-06-01
Microplastics are an emerging contaminant of concern in aquatic ecosystems. To better understand microplastic contamination in North American surface waters, we report for the first time densities of microplastics in Lake Winnipeg, the 11th largest freshwater body in the world. Samples taken 2014 to 2016 revealed similar or significantly greater microplastic densities in Lake Winnipeg compared with those reported in the Laurentian Great Lakes. Plastics in the lake were largely of secondary origin, overwhelmingly identified as fibres. We detected significantly greater densities of microplastics in the north basin compared to the south basin of the lake in 2014, but not in 2015 or 2016. Mean lake-wide densities across all years were comparable and not statistically different. Scanning electron microscopy with energy dispersive X-ray spectroscopy indicated that 23% of isolated particles on average were not plastic. While the ecological impact of microplastics on aquatic ecosystems is still largely unknown, our study contributes to the growing evidence that microplastic contamination is widespread even around sparsely-populated freshwater ecosystems, and provides a baseline for future study and risk assessments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Drinking Water Maximum Contaminant Levels (MCLs)
National Primary Drinking Water Regulations (NPDWRs or primary standards) are legally enforceable standards that apply to public water systems. Primary standards protect public health by limiting the levels of contaminants in drinking water.
Remote micro-encapsulation of curium-gold cermets
NASA Astrophysics Data System (ADS)
Coops, M. S.; Voegele, A. L.; Hayes, W. N.; Sisson, D. H.
1982-09-01
A technique has been developed to produce miniature, high-density capsules of curium-244 oxide contained in three concentric jackets of metallic gold or silver. The final capsules are right circular cylinders, 6.350 mm diameter by (3.18±0.05) mm long, with a minimum density of 11.0 g/cm 3. Each level of containment was soldered or brazed closed, with the outer surface free of detectable alpha contamination. Fabrication was performed in three separate small cells operated by standard master-slave manipulators. Production capsules have been stored for up to five years without indication of dimensional growth or leakage of radioactive contents. The dimensional stability of the capsules is attributed to the microporous structure of the plated-gold structure which permits helium gas resulting from alpha decay to diffuse through the capsule wall while retaining all radioactive materials.
Novel search algorithms for a mid-infrared spectral library of cotton contaminants.
Loudermilk, J Brian; Himmelsbach, David S; Barton, Franklin E; de Haseth, James A
2008-06-01
During harvest, a variety of plant based contaminants are collected along with cotton lint. The USDA previously created a mid-infrared, attenuated total reflection (ATR), Fourier transform infrared (FT-IR) spectral library of cotton contaminants for contaminant identification as the contaminants have negative impacts on yarn quality. This library has shown impressive identification rates for extremely similar cellulose based contaminants in cases where the library was representative of the samples searched. When spectra of contaminant samples from crops grown in different geographic locations, seasons, and conditions and measured with a different spectrometer and accessories were searched, identification rates for standard search algorithms decreased significantly. Six standard algorithms were examined: dot product, correlation, sum of absolute values of differences, sum of the square root of the absolute values of differences, sum of absolute values of differences of derivatives, and sum of squared differences of derivatives. Four categories of contaminants derived from cotton plants were considered: leaf, stem, seed coat, and hull. Experiments revealed that the performance of the standard search algorithms depended upon the category of sample being searched and that different algorithms provided complementary information about sample identity. These results indicated that choosing a single standard algorithm to search the library was not possible. Three voting scheme algorithms based on result frequency, result rank, category frequency, or a combination of these factors for the results returned by the standard algorithms were developed and tested for their capability to overcome the unpredictability of the standard algorithms' performances. The group voting scheme search was based on the number of spectra from each category of samples represented in the library returned in the top ten results of the standard algorithms. This group algorithm was able to identify correctly as many test spectra as the best standard algorithm without relying on human choice to select a standard algorithm to perform the searches.
International Space Station External Contamination Status
NASA Technical Reports Server (NTRS)
Mikatarian, Ron; Soares, Carlos
2000-01-01
PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.
NASA Astrophysics Data System (ADS)
Kang, Teawook; Oh, Je Hyeok; Hong, Jae-Sang; Kim, Dongsung
2016-09-01
We examined the effects of crude oil contamination on community assemblages of meiofauna and nematodes after exposure to total petroleum hydrocarbons in the laboratory. We administered a seawater solution that had been contaminated with total petroleum hydrocarbons to seven treatment groups at different concentrations, while the control group received uncontaminated filtered seawater. The average density of total meiofauna in the experimental microcosms diluted with 0.5%, 1%, 2%, and 4% contaminated seawater was higher than the density in the control. The average density of total meiofauna in the 8%, 15%, and 20% microcosms was lower than the density in the control. The density of nematodes was similar to that of the total meiofauna. Cluster analysis divided the microcosms into group 1 (control, 0.5%, 1%, 2%, and 4% microcosms) and group 2 (8%, 15%, and 20% microcosms). However, SIMPROF analysis showed no significant difference between the two groups ( p > 0.05). Bolbolaimus spp. (37.1%) were dominant among the nematodes. Cluster analysis showed similar results for nematode and meiofaunal communities. The total meiofaunal density, nematode density, and number of Bolbolaimus spp. individuals were significantly negatively associated with the concentration of total petroleum hydrocarbons (Spearman correlation coefficients, p < 0.05). Within the nematodes, epistrate feeders (group 2A: 46%) were the most abundant trophic group. Among the treatment groups, the abundance of group 2A increased in low-concentration microcosms and decreased in high-concentration microcosms. Thus, our findings provide information on the effects of oil pollution on meiofauna in the intertidal zones of sandy beaches.
NASA Astrophysics Data System (ADS)
Linnik, Vitaly; Sokolov, Alexander; Sokolov, Peter
2017-04-01
As a result of the Chernobyl accident on April 26, 1986, large amounts of radionuclides were released into the atmosphere, resulting in high contamination in Belarus, Ukraine, and Russia. High variability of environmental parameters and multi-scale nature of initial fallout significantly contributed to very complicated Cs-137 patterns. The first maps of radioactive contamination due to the accident at the Chernobyl nuclear power plant, built in May 1986, already identified a heterogeneous nature of the contamination zones [1]. A complex combination of factors, such as the nature of the deposition (dry, wet), various volumetric activity of radionuclides in the atmosphere during the deposition of aerosols on the earth's surface, led to the formation of multiscale fields of radionuclide contamination, where each scale correlates with "pollution spots" having their own specific nature]. Air gamma survey was conducted with a grid 100x100 m and it allowed to reveal different levels of scale "spots" of Cs-137 contamination associated with the movement of polluted air and the influence of the underlying surface - forests, river valleys. Cs-137 contamination field has an extraordinary feature - uniqueness of its spatial structure in different districts of the Bryansk region. A maximal area of "cesium" spots up to 30-50 km in size and with a contamination density of more than 1000 kBq/m2 is observed in the western part of the Bryansk Region. Their spatial structure is extremely heterogeneous, the differences in the local density of Cs-137 contamination being due to those in intensity of precipitation (wet deposition). The central part of the Bryansk Region with the density of contamination below 37 kBq/m2 (up to 3-5 kBq/m2 ) is an example of a condensing zone of "dry" deposition. With a larger scale, allowing individual elements of Cs-137 contamination to be shown in a more distinct way, it is possible to observe the relationship of contamination with a number of landscape factors. Specifically, one can find apparent relationship of Cs-137 contamination density with forests, where there is an increased deposition activity. An air gamma survey with a range of pollution 7,4-90 0 kBq/m2, conducted in the central and southern part of the Bryansk Region, revealed a complex pattern of contamination density, which is presented as a sequence of "spots" of irregular shape with a high level of radioactive contamination, as well as elongated "bands", whose orientation shows a direction of the movement of air masses, i.e., west-eastward or to the northwest- south-east. The distribution of Cs-137 contamination can be clearly related to the valley of the Sudost River, thus showing relevance of landscape factors for the formation of technogenic pollution with radionuclides. The analysis of transformation of the original Cs-137 contamination formed as a result of the deposition of radioactive aerosols in April-May 1986, due to the effect of landscape factors, has been performed. 1. Izrael Yu. A., Kvasnikova E.V., Linnik V.G. 2012 Radioactive contamination in Russia //Changing the natural environment of Russia in the 20th century (in Russian). Eds. V. M. Kotlyakov, D.I. Lyuri. Moscow: Publishing House Molnet. Pp.202-220.
40 CFR 268.49 - Alternative LDR treatment standards for contaminated soil.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for contaminated soil. 268.49 Section 268.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... treatment standards for contaminated soil. (a) Applicability. You must comply with LDRs prior to placing soil that exhibits a characteristic of hazardous waste, or exhibited a characteristic of hazardous...
40 CFR 268.49 - Alternative LDR treatment standards for contaminated soil.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for contaminated soil. 268.49 Section 268.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... treatment standards for contaminated soil. (a) Applicability. You must comply with LDRs prior to placing soil that exhibits a characteristic of hazardous waste, or exhibited a characteristic of hazardous...
40 CFR 268.49 - Alternative LDR treatment standards for contaminated soil.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for contaminated soil. 268.49 Section 268.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... treatment standards for contaminated soil. (a) Applicability. You must comply with LDRs prior to placing soil that exhibits a characteristic of hazardous waste, or exhibited a characteristic of hazardous...
40 CFR 268.49 - Alternative LDR treatment standards for contaminated soil.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for contaminated soil. 268.49 Section 268.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... treatment standards for contaminated soil. (a) Applicability. You must comply with LDRs prior to placing soil that exhibits a characteristic of hazardous waste, or exhibited a characteristic of hazardous...
40 CFR 268.49 - Alternative LDR treatment standards for contaminated soil.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for contaminated soil. 268.49 Section 268.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... treatment standards for contaminated soil. (a) Applicability. You must comply with LDRs prior to placing soil that exhibits a characteristic of hazardous waste, or exhibited a characteristic of hazardous...
Bien-Aimé, K; Belin, C; Gallais, L; Grua, P; Fargin, E; Néauport, J; Tovena-Pecault, I
2009-10-12
The impact of storage conditions on laser induced damage density at 351 nm on bare fused polished silica samples has been studied. Intentionally outgassing of polypropylene pieces on silica samples was done. We evidenced an important increase of laser induced damage density on contaminated samples demonstrating that storage could limit optics lifetime performances. Atomic Force Microscopy (AFM) and Gas Chromatography -Mass Spectrometry (GC-MS) have been used to identify the potential causes of this effect. It shows that a small quantity of organic contamination deposited on silica surface is responsible for this degradation. Various hypotheses are proposed to explain the damage mechanism. The more likely hypothesis is a coupling between surface defects of optics and organic contaminants.
CHEMICAL CONTAMINATION AND TOXICITY ASSOCIATED WITH A COASTAL GOLF COURSE COMPLEX
The increasing density of golf courses represents a potential source of contamination to nearby coastal areas, the chemical and biological magnitude of which is almost unknown. The objective of this study was to compare the concentrations of contaminants and toxicities of sedime...
SEDIMENT CHEMICAL CONTAMINATION AND TOXICITY ASSOCIATED WITH A COASTAL GOLF COURSE COMPLEX.
The increasing density of golf courses represents a potential source of sediment contamination to nearby coastal areas, the chemical and biological magnitude of which is almost unknown. The objective of this study was to determine the concentrations of contaminants and toxicities...
Deng, Lin; Li, Zhu; Wang, Jie; Liu, Hongyan; Li, Na; Wu, Longhua; Hu, Pengjie; Luo, Yongming; Christie, Peter
2016-01-01
In two long-term field experiments the zinc (Zn)/cadmium (Cd) hyperaccumulator Sedum plumbizincicola (S. plumbizincicola) was examined to optimize the phytoextraction of metal contaminated soil by two agronomic strategies of intercropping with maize (Zea mays) and plant densities. Soil total Zn and Cd concentrations decreased markedly after long-term phytoextraction. But shoot biomass and Cd and Zn concentrations showed no significant difference with increasing remediation time. In the intercropping experiment the phytoremediation efficiency in the treatment "S. plumbizincicola intercropped with maize" was higher than in S. plumbizincicola monocropping, and Cd concentrations of corn were below the maximum national limit. In the plant density experiment the phytoremediation efficiency increased with increasing plant density and 440,000 plants ha(-1) gave the maximum rate. These results indicated that S. plumbizincicola at an appropriate planting density and intercropped with maize can achieve high remediation efficiency to contaminated soil without affecting the cereal crop productivity. This cropping system combines adequate agricultural production with soil heavy metal phytoextraction.
Development of Low Density Titanium Alloys for Structural Applications
NASA Technical Reports Server (NTRS)
Froes, F. H.; Suryanarayana, C.; Powell, C.; Ward-Close, C. Malcolm; Wilkes, D. M. J.
1996-01-01
In this report the results of a program designed to reduce the density of titanium by adding magnesium are presented. Because these two elements are immiscible under conventional ingot metallurgy techniques, two specialized powder metallurgy methods namely, mechanical alloying (MA) and physical vapor deposition (PVD) were implemented. The mechanical alloying experiments were done both at the University of Idaho and at the Defense Research Agency in UK. Since titanium is reactive with interstitial elements, a secondary goal of this research was to correlate solubility extensions with interstitial contamination content, especially oxygen and nitrogen. MA was carried out in SPEX 8000 shaker mils and different milling containers were utilized to control the level of contamination. Results showed that solubilities of Mg in Ti were obtained up to 28 at.% (16.4 wt. %) Mg in Ti for Ti-39.6 at. % (25 wt. %) Mg alloys, which greatly exceed those obtained under equilibrium conditions. This reflects a density reduction of approximately 26 %. Contamination of oxygen and nitrogen seemed to increase the solubility of magnesium in titanium in some cases; however, we were not able to make a clear correlation between contamination levels with solubilities. Work at the DRA has emphasized optimization of present PVD equipment, specifically composition and temperature control. Preliminary PVD data has shown Ti-Mg deposits have successfully been made up to 2 mm thick and that solubility extensions were achieved. The potential for density reduction of titanium by alloying with magnesium has been demonstrated; however, this work has only scratched the surface of the development of such low density alloys. Much research is needed before such alloys could be implemented into industry. Further funding is required in order to optimize the MA/PVD processes including contamination control, determination of optimal alloy compositions, microstructure development, and mechanical property determination.
Fujinaga, Aiichiro; Uchiyama, Iwao; Morisawa, Shinsuke; Yoneda, Minoru; Sasamoto, Yuzuru
2012-01-01
In Japan, environmental standards for contaminants in groundwater and in leachate from soil are set with the assumption that they are used for drinking water over a human lifetime. Where there is neither a well nor groundwater used for drinking, the standard is thus too severe. Therefore, remediation based on these standards incurs excessive effort and cost. In contrast, the environmental-assessment procedure used in the United States and the Netherlands considers the site conditions (land use, existing wells, etc.); however, a risk assessment is required for each site. Therefore, this study proposes a new framework for judging contamination in Japan by considering the merits of the environmental standards used and a method for risk assessment. The framework involves setting risk-based concentrations that are attainable remediation goals for contaminants in soil and groundwater. The framework was then applied to a model contaminated site for risk management, and the results are discussed regarding the effectiveness and applicability of the new methodology. © 2011 Society for Risk Analysis.
Rochman, Chelsea M; Lewison, Rebecca L; Eriksen, Marcus; Allen, Harry; Cook, Anna-Marie; Teh, Swee J
2014-04-01
The accumulation of plastic debris in pelagic habitats of the subtropical gyres is a global phenomenon of growing concern, particularly with regard to wildlife. When animals ingest plastic debris that is associated with chemical contaminants, they are at risk of bioaccumulating hazardous pollutants. We examined the relationship between the bioaccumulation of hazardous chemicals in myctophid fish associated with plastic debris and plastic contamination in remote and previously unmonitored pelagic habitats in the South Atlantic Ocean. Using a published model, we defined three sampling zones where accumulated densities of plastic debris were predicted to differ. Contrary to model predictions, we found variable levels of plastic debris density across all stations within the sampling zones. Mesopelagic lanternfishes, sampled from each station and analyzed for bisphenol A (BPA), alkylphenols, alkylphenol ethoxylates, polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs), exhibited variability in contaminant levels, but this variability was not related to plastic debris density for most of the targeted compounds with the exception of PBDEs. We found that myctophid sampled at stations with greater plastic densities did have significantly larger concentrations of BDE#s 183 -209 in their tissues suggesting that higher brominated congeners of PBDEs, added to plastics as flame-retardants, are indicative of plastic contamination in the marine environment. Our results provide data on a previously unsampled pelagic gyre and highlight the challenges associated with characterizing plastic debris accumulation and associated risks to wildlife. Copyright © 2014 Elsevier B.V. All rights reserved.
Domestic wells have high probability of pumping septic tank leachate
NASA Astrophysics Data System (ADS)
Bremer, J. E.; Harter, T.
2012-08-01
Onsite wastewater treatment systems are common in rural and semi-rural areas around the world; in the US, about 25-30% of households are served by a septic (onsite) wastewater treatment system, and many property owners also operate their own domestic well nearby. Site-specific conditions and local groundwater flow are often ignored when installing septic systems and wells. In areas with small lots (thus high spatial septic system densities), shallow domestic wells are prone to contamination by septic system leachate. Mass balance approaches have been used to determine a maximum septic system density that would prevent contamination of groundwater resources. In this study, a source area model based on detailed groundwater flow and transport modeling is applied for a stochastic analysis of domestic well contamination by septic leachate. Specifically, we determine the probability that a source area overlaps with a septic system drainfield as a function of aquifer properties, septic system density and drainfield size. We show that high spatial septic system density poses a high probability of pumping septic system leachate. The hydraulic conductivity of the aquifer has a strong influence on the intersection probability. We find that mass balance calculations applied on a regional scale underestimate the contamination risk of individual drinking water wells by septic systems. This is particularly relevant for contaminants released at high concentrations, for substances that experience limited attenuation, and those that are harmful even at low concentrations (e.g., pathogens).
A comparison of data-driven groundwater vulnerability assessment methods
Sorichetta, Alessandro; Ballabio, Cristiano; Masetti, Marco; Robinson, Gilpin R.; Sterlacchini, Simone
2013-01-01
Increasing availability of geo-environmental data has promoted the use of statistical methods to assess groundwater vulnerability. Nitrate is a widespread anthropogenic contaminant in groundwater and its occurrence can be used to identify aquifer settings vulnerable to contamination. In this study, multivariate Weights of Evidence (WofE) and Logistic Regression (LR) methods, where the response variable is binary, were used to evaluate the role and importance of a number of explanatory variables associated with nitrate sources and occurrence in groundwater in the Milan District (central part of the Po Plain, Italy). The results of these models have been used to map the spatial variation of groundwater vulnerability to nitrate in the region, and we compare the similarities and differences of their spatial patterns and associated explanatory variables. We modify the standard WofE method used in previous groundwater vulnerability studies to a form analogous to that used in LR; this provides a framework to compare the results of both models and reduces the effect of sampling bias on the results of the standard WofE model. In addition, a nonlinear Generalized Additive Model has been used to extend the LR analysis. Both approaches improved discrimination of the standard WofE and LR models, as measured by the c-statistic. Groundwater vulnerability probability outputs, based on rank-order classification of the respective model results, were similar in spatial patterns and identified similar strong explanatory variables associated with nitrate source (population density as a proxy for sewage systems and septic sources) and nitrate occurrence (groundwater depth).
de Lucia, Giuseppe Andrea; Caliani, Ilaria; Marra, Stefano; Camedda, Andrea; Coppa, Stefania; Alcaro, Luigi; Campani, Tommaso; Giannetti, Matteo; Coppola, Daniele; Cicero, Anna Maria; Panti, Cristina; Baini, Matteo; Guerranti, Cristiana; Marsili, Letizia; Massaro, Giorgio; Fossi, Maria Cristina; Matiddi, Marco
2014-09-01
A plethora of different sampling methodologies has been used to document the presence of micro-plastic fragments in sea water. European Marine Strategy suggests to improve standard techniques to make future data comparable. We use Manta Trawl sampling technique to quantify abundance and distribution of micro-plastic fragments in Sardinian Sea (Western Mediterranean), and their relation with phthalates and organoclorine in the neustonic habitat. Our results highlight a quite high average plastic abundance value (0.15 items/m(3)), comparable to the levels detected in other areas of the Mediterranean. "Site" is the only factor that significantly explains the differences observed in micro-plastic densities. Contaminant levels show high spatial and temporal variation. In every station, HCB is the contaminant with the lowest concentration while PCBs shows the highest levels. This work, in line with Marine Strategy directives, represents a preliminary study for the analysis of plastic impact on marine environment of Sardinia. Copyright © 2014 Elsevier Ltd. All rights reserved.
Shuttle Upper Atmosphere Mass Spectrometer Experimental Flight Results
NASA Technical Reports Server (NTRS)
Blanchard, R. C.; Ozoroski, Thomas A.; Nicholson, John Y.
1994-01-01
Calibrated pressure measurements for species with mass-to-charge ratios up to 50 amu/e(-) were obtained trom the shuttle upper atmosphere mass spectrometer experiment during re-entry on the STS-35 mission. The principal experimental objective is to obtain measurements of freestream density in the hypersonic rarefied flow flight regime. Data were collected from 180 to about 87 km. However, data above 115 km were contaminated from a source of gas emanating from pressure transdueers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data are compared to the mass spectrometer total pressure with excellent agreement. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions. The freestream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. Standard Atmosphere model, exhibits the wavelike nature seen on previous flights using accelerometry. Selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump.
Gómez-Álvarez, Sandra; Porta-Oltra, Begoña; Hernandez-Griso, Marta; Pérez-Labaña, Francisca; Climente-Martí, Mónica
2016-01-01
to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systems. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
NASA Astrophysics Data System (ADS)
Barnhart, E. P.; Ruppert, L. F.; Orem, W. H.; McIntosh, J. C.; Cunningham, A. B.; Fields, M. W.; Hiebert, R.; Hyatt, R.
2016-12-01
There is an increasing threat that deep aquifers, an important drinking water resource, may be contaminated by the extraction and transport of fossil fuels. This threat increases the need for improved groundwater monitoring and the ability to predict the extent to which microbial activity may remediate such contamination. The characterization of subsurface microbial communities could provide an ideal biomonitoring tool for the assessment of subsurface contamination due to prokaryotes environmental ubiquity, rapidity of response to environmental perturbation and the important role they play in hydrocarbon degradation and bioremediation. New DNA sequencing technologies provide the opportunity to cost-effectively identify the vast subsurface microbial ecosystem, but use of this new technology is restricted due to issues with sampling. Prior subsurface microbiology studies have relied on core samples that are expensive to obtain hard to collect aseptically and/or ground water samples that do not reflect in situ microbial densities or activities. The development of down-well incubation of sterile sediment with a Diffusive Microbial Sampler (DMS) has emerged as an alternative method to sample subsurface microbial communities that minimizes cost and contamination issues associated with traditional methods. We have designed a Subsurface Environment Sampler with a DMS module that could enable the anaerobic transport of the in situ microbial community from the field for laboratory bioremediation studies. This sampler could provide an inexpensive and standard method for subsurface microbial sampling which would make this tool useful for Federal, State, private and local agencies interested in monitoring contamination or the effectiveness of bioremediation activities in subsurface aquifers.
USDA-ARS?s Scientific Manuscript database
Metal contaminants in soils can persist for millennia, causing lasting negative impacts on local ecosystems. Long-term contaminant bioavailability is related to soil pH and the strength and stability of their solid phase associations. We combined physical density separation with synchrotron-based mi...
Milk and serum standard reference materials for monitoring organic contaminants in human samples.
Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A
2013-02-01
Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.
Milk and serum standard reference materials for monitoring organic contaminants in human samples
Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N. Alan; Heltsley, Rebecca M.; Hoover, Dale; Keller, Jennifer M.; Leigh, Stefan D.; Patterson, Donald G.; Pintar, Adam L.; Sharpless, Katherine E.; Sjödin, Andreas; Turner, Wayman E.; Vander Pol, Stacy S.; Wise, Stephen A.
2016-01-01
Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4′-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis. PMID:23132544
NASA Astrophysics Data System (ADS)
Huang, H.-P.; Wright, I. P.; Gilmour, I.; Pillinger, C. T.
1994-11-01
Silica aerogel represents an ideal material for use as a cosmic dust capture medium. Its low density enables impacting particles to decelerate and stop within a small quality of the material, but without any severe heating. Hence the particles, which remain unmelted, can subsequently be removed and studied. Since a large proportion of the prospective cosmic dust is likely to be enriched in elements such as carbon and hydrogen (typically 5 wt% C, 20 wt% H2O), it is imperative that the aerogel used in the capture cell contains minimal quantities of these elements. Unfortunately the lowest density aerogels contain carbon at levels of 5 wt%; water is present in even greater amounts. Thus, techniques need to be identified to remove these contaminants. Herein, an attempt is made to use supercritical fluid extraction to remove carbon (and water). The investigation was tried to identify the most suitable parameters (i.e. CO2 density, solvating power using single or multiple extractions, use of modifier, etc.) necessary for removal of contaminants. A set of conditions was derived which was able to remove 90% of carbon contaminants from an aerogel of 0.12 g/cu cm density. This involved the use of multiple extractions with gradient temperatures (i.e. variable CO2 density), but without the use of a methanol modifier. Unfortunately, the same technique was less efficacious at removing carbon from aerogels with densities less than 0.12 g/cu cm. At present the extraction procedure has only been tried on a laboratory scale, but clearly this could be scaled-up in the future.
Standardization of Rocket Engine Pulse Time Parameters
NASA Technical Reports Server (NTRS)
Larin, Max E.; Lumpkin, Forrest E.; Rauer, Scott J.
2001-01-01
Plumes of bipropellant thrusters are a source of contamination. Small bipropellant thrusters are often used for spacecraft attitude control and orbit correction. Such thrusters typically operate in a pulse mode, at various pulse lengths. Quantifying their contamination effects onto spacecraft external surfaces is especially important for long-term complex-geometry vehicles, e.g. International Space Station. Plume contamination tests indicated the presence of liquid phase contaminant in the form of droplets. Their origin is attributed to incomplete combustion. Most of liquid-phase contaminant is generated during the startup and shutdown (unsteady) periods of thruster pulse. These periods are relatively short (typically 10-50 ms), and the amount of contaminant is determined by the thruster design (propellant valve response, combustion chamber size, thruster mass flow rate, film cooling percentage, dribble volume, etc.) and combustion process organization. Steady-state period of pulse is characterized by much lower contamination rates, but may be lengthy enough to significantly conh'ibute to the overall contamination effect. Because there was no standard methodology for thruster pulse time division, plume contamination tests were conducted at various pulse durations, and their results do not allow quantifying contaminant amounts from each portion of the pulse. At present, the ISS plume contamination model uses an assumption that all thrusters operate in a pulse mode with the pulse length being 100 ms. This assumption may lead to a large difference between the actual amounts of contaminant produced by the thruster and the model predictions. This paper suggests a way to standardize thruster startup and shutdown period definitions, and shows the usefulness of this approach to better quantify thruster plume contamination. Use of the suggested thruster pulse time-division technique will ensure methodological consistency of future thruster plume contamination test programs, and allow accounting for thruster pulse length when modeling plume contamination and erosion effects.
REPRESENTATIVE SAMPLING AND ANALYSIS OF HETEROGENEOUS SOILS
Standard sampling and analysis methods for hazardous substances in contaminated soils currently are available and routinely employed. Standard methods inherently assume a homogeneous soil matrix and contaminant distribution; therefore only small sample quantities typically are p...
Liu, Zhibin; Liu, Songyu; Cai, Yi; Fang, Wei
2015-06-01
As the dielectric constant and conductivity of petroleum products are different from those of the pore water in soil, the electrical resistivity characteristics of oil-contaminated soil will be changed by the corresponding oil type and content. The contaminated soil specimens were manually prepared by static compaction method in the laboratory with commercial kaolin clay and diesel oil. The water content and dry density of the first group of soil specimens were controlled at 10 % and 1.58 g/cm(3). Corresponding electrical resistivities of the contaminated specimens were measured at the curing periods of 7, 14, and 28 and 90, 120, and 210 days on a modified oedometer cell with an LCR meter. Then, the electrical resistivity characteristics of diesel oil-contaminated kaolin clay were discussed. In order to realize a resistivity-based oil detection method, the other group of oil-contaminated kaolin clay specimens was also made and tested, but the initial water content, oil content, and dry density were controlled at 0~18 %, 0~18 %, 1.30~1.95 g/cm(3), respectively. Based on the test data, a resistivity-based artificial neural network (ANN) was developed. It was found that the electrical resistivity of kaolin clay decreased with the increase of oil content. Moreover, there was a good nonlinear relationship between electrical resistivity and corresponding oil content when the water content and dry density were kept constant. The decreasing velocity of the electrical resistivity of oil-contaminated kaolin clay was higher before the oil content of 12 % than after 12 %, which indicated a transition of the soil from pore water-controlled into oil-controlled electrical resistivity characteristics. Through microstructural analysis, the decrease of electrical resistivity could be explained by the increase of saturation degree together with the collapse of the electrical double layer. Environmental scanning electron microscopy (ESEM) photos indicated that the diesel oil in kaolin clay normally had three kinds of effects including oil filling, coating, and bridging. Finally, a resistivity-based ANN model was established based on the database collected from the experiment data. The performance of the model was proved to be reasonably accepted, which puts forward a possible simple, economic, and effective tool to detect the oil content in contaminated clayey soils just with four basic parameters: wet density, dry density, measured moisture content, and electrical resistivity.
Xu, Hui Qiu; Huang, Yin Hua; Wu, Zhi Feng; Cheng, Jiong; Li, Cheng
2016-10-01
Based on 641 agricultural top soil samples (0-20 cm) and land use map in 2005 of Guangzhou, we used single-factor pollution indices and Pearson/Spearman correlation and partial redundancy analyses and quantified the soil contamination with As and Cd and their relationships with landscape heterogeneity at three grid scales of 2 km×2 km, 5 km×5 km, and 10 km×10 km as well as the determinant landscape heterogeneity factors at a certain grid scale. 5.3% and 7.2% of soil samples were contaminated with As and Cd, respectively. At the three scales, the agricultural soil As and Cd contamination were generally significantly correlated with parent materials' composition, river/road density and landscape patterns of several land use types, indicating the parent materials, sewage irrigation and human activities (e.g., industrial and traffic activities, and the additions of pesticides and fertilizers) were possibly the main input pathways of trace metals. Three subsets of landscape heterogeneity variables (i.e., parent materials, distance-density variables, and landscape patterns) could explain 12.7%-42.9% of the variation of soil contamination with As and Cd, of which the explanatory power increased with the grid scale and the determinant factors varied with scales. Parent materials had higher contribution to the variations of soil contamination at the 2 and 10 km grid scales, while the contributions of landscape patterns and distance-density variables generally increased with the grid scale. Adjusting the distribution of cropland and optimizing the landscape pattern of land use types are important ways to reduce soil contamination at local scales, which urban planners and decision makers should pay more attention to.
Rosenfeld, Carla E.; Chaney, Rufus L.; Tappero, Ryan V.; ...
2017-03-17
Here, metal contaminants in soils can persist for millennia, causing lasting negative impacts on local ecosystems. Long-term contaminant bioavailability is related to soil pH and to the strength and stability of solid-phase associations. We combined physical density separation with synchrotron-based microspectroscopy to reduce solid-phase complexity and to study Zn speciation in field-contaminated soils. We also investigated Zn uptake in two Zn-hyperaccumulating ecotypes of Noccaea caerulescens (Ganges and Prayon). Soils were either moderately contaminated (500–800 mg Zn kg –1 via contaminated biosolids application) or grossly enriched (26,000 mg Zn kg –1 via geogenic enrichment). Soils were separated using sodium polytungstate intomore » three fractions: light fraction (LF) (<1.6 g cm –3), medium fraction (MF) (1.6–2.8 g cm –3), and heavy fraction (HF) (>2.8 g cm –3). Approximately 45% of the total Zn was associated with MF in biosolids-contaminated soils. From these data, we infer redistribution to the MF after biosolids application because Zn in biosolids is principally associated with HF and LF. Our results suggest that increasing proportions of HF-associated Zn in soils may be related to greater relative Zn removal by Zn hyperaccumulating plants. Using density fractions enabled assessment of Zn speciation on a microscale despite incomplete fractionation. Analyzing both density fractions and whole soils revealed certain phases (e.g., ZnS, Zn coprecipitated with Fe oxides) that were not obvious in all analyses, indicating multiple views of the same soils enable a more complete understanding of Zn speciation.« less
NASA Astrophysics Data System (ADS)
Rogers, Keir K.; Bird, Simeon; Peiris, Hiranya V.; Pontzen, Andrew; Font-Ribera, Andreu; Leistedt, Boris
2018-05-01
Correlations measured in three dimensions in the Lyman-alpha forest are contaminated by the presence of the damping wings of high column density (HCD) absorbing systems of neutral hydrogen (H I; having column densities N(H I) > 1.6 × 10^{17} atoms cm^{-2}), which extend significantly beyond the redshift-space location of the absorber. We measure this effect as a function of the column density of the HCD absorbers and redshift by measuring three-dimensional (3D) flux power spectra in cosmological hydrodynamical simulations from the Illustris project. Survey pipelines exclude regions containing the largest damping wings. We find that, even after this procedure, there is a scale-dependent correction to the 3D Lyman-alpha forest flux power spectrum from residual contamination. We model this residual using a simple physical model of the HCD absorbers as linearly biased tracers of the matter density distribution, convolved with their Voigt profiles and integrated over the column density distribution function. We recommend the use of this model over existing models used in data analysis, which approximate the damping wings as top-hats and so miss shape information in the extended wings. The simple `linear Voigt model' is statistically consistent with our simulation results for a mock residual contamination up to small scales (|k| < 1 h Mpc^{-1}). It does not account for the effect of the highest column density absorbers on the smallest scales (e.g. |k| > 0.4 h Mpc^{-1} for small damped Lyman-alpha absorbers; HCD absorbers with N(H I) ˜ 10^{21} atoms cm^{-2}). However, these systems are in any case preferentially removed from survey data. Our model is appropriate for an accurate analysis of the baryon acoustic oscillations feature. It is additionally essential for reconstructing the full shape of the 3D flux power spectrum.
Kowallis, B.J.; Christiansen, E.H.; Everett, B.H.; Crowley, K.D.; Naeser, C.W.; Miller, D.S.; Deino, A.L.
1993-01-01
Secondary age standards are valuable in intra- and interlaboratory calibration. At present very few such standards are available for fission track dating that is older than Tertiary. Several altered volcanic ash beds occur in the Middle Jurassic Carmel Formation in southwestern Utah. The formation was deposited in a shallow marine/sabhka environment. Near Gunlock, Utah, eight ash beds have been identified. Sanidines from one of the ash beds (GUN-F) give a single-crystal laser-probe 40Ar/39Ar age of 166.3??0.8 Ma (2??). Apatite and zircon fission track ages range from 152-185 Ma with typically 15-20 Ma errors (2??). Track densities in zircons are high and most grains are not countable. Apatites are fairly common in most of the ash beds and have reasonable track densities ranging between 1.2-1.5 ?? 106 tracks/cm2. Track length distributions in apatites are unimodal, have standard deviations <1??m, and mean track lengths of about 14-14.5 ??m. High Cl apatites (F:Cl:OH ratio of 39:33:28) are particularly abundant and large in ash GUN-F, and are fairly easy to concentrate, but the concentrates contain some siderite, most of which can be removed by sieving. GUN-F shows evidence of some reworking and detriaal contamination based on older single grain 40Ar/39Ar analyses and some rounding of grains, but the apatite population appears to be largely uncontaminated. At present BJK has approximately 12 of apatite separate from GUN-F. ?? 1993.
Claro, Tânia; O'Reilly, Marese; Daniels, Stephen; Humphreys, Hilary
2015-09-01
Contamination of hospital surfaces by bacteria is increasingly recognized. We assessed commonly touched surfaces using contact plates and Petrifilms (3M, St. Paul, MN) and compared the results against proposed microbiology standards. Toilet door handles were the most heavily contaminated (7.97 ± 0.68 colony forming units [CFU]/cm(2)) and exceeded proposed standards on 74% of occasions. Petrifilms detected statistically higher CFU from bedside lockers. Further research is required on the use of standards and methods of sampling. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
[Contamination of exosome preparations, isolated from biological fluids].
Grigor'eva, A E; Dyrkheeva, N S; Bryzgunova, O E; Tamkovich, S N; Chelobanov, B P; Ryabchikova, E I
2017-01-01
The aim of our study was to attract the attention of researchers at the problem of contamination of exosome preparations. Using a transmission electron microscope JEM-1400 ("JEOL", Japan) we have examined exosome preparations, isolated according to the conventional scheme of sequential centrifugation from different biological fluids: plasma and urine of healthy persons and patients with oncologic diseases, bovine serum, and culture fluid (MDCK, MDA-MB и MCF-7 cells). All exosome preparations (over 200) contained exosomes, which were identified by immuno-electron microscopy using antibodies to tetraspanins CD63 or CD9. Besides exosomes, all the studied preparations contained contaminating structures: distinct particles of low electron density without limiting membrane ("non-vesicles"). Two main kinds of the "non-vesicles" species were found in exosome preparations: 20-40 nm in size, representing 10-40% of all structures in the preparations; and 40-100 nm in size (identical to exosomes by size). Morphology of the "non-vesicles" allowed to identify them as lipoproteins of intermediate and low density (20-40 nm), and very low density (40-100 nm). The highest level of the contamination was detected in exosome preparations, isolated from blood samples. The results of our study indicate the need to control the composition of exosome preparation by electron microscopy and take into account the presence of contaminating structures in analysis of experimental data.
Associative diazotrophic bacteria in grass roots and soils from heavy metal contaminated sites.
Moreira, Fátima M S; Lange, Anderson; Klauberg-Filho, Osmar; Siqueira, José O; Nóbrega, Rafaela S A; Lima, Adriana S
2008-12-01
This work aimed to evaluate density of associative diazotrophic bacteria populations in soil and grass root samples from heavy metal contaminated sites, and to characterize isolates from these populations, both, phenotypically (Zinc, Cadmium and NaCl tolerance in vitro, and protein profiles) and genotypically (16S rDNA sequencing), as compared to type strains of known diazotrophic species. Densities were evaluated by using NFb, Fam and JNFb media, commonly used for enrichment cultures of diazotrophic bacteria. Bacterial densities found in soil and grass root samples from contaminated sites were similar to those reported for agricultural soils. Azospirillum spp. isolates from contaminated sites and type strains from non-contaminated sites varied substantially in their in vitro tolerance to Zn+2 and Cd+2, being Cd+2 more toxic than Zn+2. Among the most tolerant isolates (UFLA 1S, 1R, S181, S34 and S22), some (1R, S34 and S22) were more tolerant to heavy metals than rhizobia from tropical and temperate soils. The majority of the isolates tolerant to heavy metals were also tolerant to salt stress as indicated by their ability to grow in solid medium supplemented with 30 g L(-1) NaCl. Five isolates exhibited high dissimilarity in protein profiles, and the 16S rDNA sequence analysis of two of them revealed new sequences for Azospirillum.
Esler, Daniel N.; Bowman, Timothy D.; O'Clair, Charles E.; Dean, Thomas A.; McDonald, Lyman L.
2000-01-01
We evaluated variation in densities of Barrow's Goldeneyes (Bucephala islandica) during winter at 214 sites within oiled and unoiled study areas in Prince William Sound, Alaska in relation to physical habitat attributes, prey biomass, and history of habitat contamination by the 1989 Exxon Valdez oil spill. Using general linear model analyses, we found that goldeneye densities were positively associated with occurrence of a stream within 200 m, lack of exposure to wind and waves, and mixed (versus rocky) substrate. We speculate that these associations relate to habitat profitability via selection of beneficial attributes and avoidance of detrimental features. We also determined that biomass of blue mussels (Mytilus trossulus), the primary prey, was not related to Barrow's Goldeneye densities; we suggest that mussel standing stock exceeds predation demands in our study areas and, thus, does not dictate goldeneye distribution. After accounting for habitat effects, we detected no effect of history of oil contamination on Barrow's Goldeneye densities, suggesting that populations have recovered from the oil spill. Although other studies documented hydrocarbon exposure in Barrow's Goldeneyes through at least 1997, either the level of exposure did not affect populations via reductions in survival, or effects of oil exposure were offset by immigration.
NASA Astrophysics Data System (ADS)
Abbas, M.; Jardani, A.; Soueid Ahmed, A.; Revil, A.; Brigaud, L.; Bégassat, Ph.; Dupont, J. P.
2017-11-01
Mapping the redox potential of shallow aquifers impacted by hydrocarbon contaminant plumes is important for the characterization and remediation of such contaminated sites. The redox potential of groundwater is indicative of the biodegradation of hydrocarbons and is important in delineating the shapes of contaminant plumes. The self-potential method was used to reconstruct the redox potential of groundwater associated with an organic-rich contaminant plume in northern France. The self-potential technique is a passive technique consisting in recording the electrical potential distribution at the surface of the Earth. A self-potential map is essentially the sum of two contributions, one associated with groundwater flow referred to as the electrokinetic component, and one associated with redox potential anomalies referred to as the electroredox component (thermoelectric and diffusion potentials are generally negligible). A groundwater flow model was first used to remove the electrokinetic component from the observed self-potential data. Then, a residual self-potential map was obtained. The source current density generating the residual self-potential signals is assumed to be associated with the position of the water table, an interface characterized by a change in both the electrical conductivity and the redox potential. The source current density was obtained through an inverse problem by minimizing a cost function including a data misfit contribution and a regularizer. This inversion algorithm allows the determination of the vertical and horizontal components of the source current density taking into account the electrical conductivity distribution of the saturated and non-saturated zones obtained independently by electrical resistivity tomography. The redox potential distribution was finally determined from the inverted residual source current density. A redox map was successfully built and the estimated redox potential values correlated well with in-situ measurements.
Juang, K W; Lee, D Y; Ellsworth, T R
2001-01-01
The spatial distribution of a pollutant in contaminated soils is usually highly skewed. As a result, the sample variogram often differs considerably from its regional counterpart and the geostatistical interpolation is hindered. In this study, rank-order geostatistics with standardized rank transformation was used for the spatial interpolation of pollutants with a highly skewed distribution in contaminated soils when commonly used nonlinear methods, such as logarithmic and normal-scored transformations, are not suitable. A real data set of soil Cd concentrations with great variation and high skewness in a contaminated site of Taiwan was used for illustration. The spatial dependence of ranks transformed from Cd concentrations was identified and kriging estimation was readily performed in the standardized-rank space. The estimated standardized rank was back-transformed into the concentration space using the middle point model within a standardized-rank interval of the empirical distribution function (EDF). The spatial distribution of Cd concentrations was then obtained. The probability of Cd concentration being higher than a given cutoff value also can be estimated by using the estimated distribution of standardized ranks. The contour maps of Cd concentrations and the probabilities of Cd concentrations being higher than the cutoff value can be simultaneously used for delineation of hazardous areas of contaminated soils.
Borrok, David M; Fein, Jeremy B; Kulpa, Charles F
2004-11-01
To model the effects of bacterial metal adsorption in contaminated environments, results from metal adsorption experiments involving individual pure stains of bacteria must be extrapolated to systems in which potentially dozens of bacterial species are present. This extrapolation may be made easier because bacterial consortia from natural environments appear to exhibit similar metal binding properties. However, bacteria that thrive in highly perturbed contaminated environments may exhibit significantly different adsorptive behavior. Here we measure proton and Cd adsorption onto a range of bacterial consortia grown from heavily contaminated industrial wastes, groundwater, and soils. We model the results using a discrete site surface complexation approach to determine binding constants and site densities for each consortium. The results demonstrate that bacterial consortia from different contaminated environments exhibit a range of total site densities (approximately a 3-fold difference) and Cd-binding constants (approximately a 10-fold difference). These ranges for Cd binding constants may be small enough to suggest that bacteria-metal adsorption in contaminated environments can be described using relatively few "averaged" bacteria-metal binding constants (in conjunction with the necessary binding constants for competing surfaces and ligands). However, if additional precision is necessary, modeling parameters must be developed separately for each contaminated environment of interest.
Advances in sublimation studies for particles of explosives
NASA Astrophysics Data System (ADS)
Furstenberg, Robert; Nguyen, Viet; Fischer, Thomas; Abrishami, Tara; Papantonakis, Michael; Kendziora, Chris; Mott, David R.; McGill, R. Andrew
2015-05-01
When handling explosives, or related surfaces, the hands routinely become contaminated with particles of explosives and related materials. Subsequent contact with a solid surface results in particle crushing and deposition. These particles provide an evidentiary trail which is useful for security applications. As such, the opto-physico-chemical characteristics of these particles are critical to trace explosives detection applications in DOD or DHS arenas. As the persistence of these particles is vital to their forensic exploitation, it is important to understand which factors influence their persistence. The longevity or stability of explosives particles on a substrate is a function of several environmental parameters or particle properties including: Vapor pressure, particle geometry, airflow, particle field size, substrate topography, humidity, reactivity, adlayers, admixtures, particle areal density, and temperature. In this work we deposited particles of 2,4-dinitrotoluene on standard microscopy glass slides by particle sieving and studied their sublimation as a function of airflow velocity, areal particle density and particle field size. Analysis of 2D microscopic images was used to compute and track particle size and geometrical characteristics. The humidity, temperature and substrate type were kept constant for each experiment. A custom airflow cell, using standard microscopy glass slide, allowed in-situ photomicroscopy. Areal particle densities and airflow velocities were selected to provide relevant loadings and flow velocities for a range of potential applications. For a chemical of interest, we define the radial sublimation velocity (RSV) for the equivalent sphere of a particle as the parameter to characterize the sublimation rate. The RSV is a useful parameter because it is independent of particle size. The sublimation rate for an ensemble of particles was found to significantly depend on airflow velocity, the areal density of the particles, and the particle field size. To compare sublimation studies these parameters must be known.
Avison, M; Hart, G
2001-06-01
The aim of this study was to reduce airborne contamination resulting from the use of aerosols in lung ventilation scintigraphy. Lung ventilation imaging is frequently performed with 99mTc-diethylenetriaminepentaacetate aerosol (DTPA), derived from a commercial nebuliser. Airborne contamination is a significant problem with this procedure; it results in exposure of staff to radiation and can reduce gamma camera performance when the ventilation is performed in the camera room. We examined the level of airborne contamination resulting from the standard technique with one of the most popular nebuliser kits and tested a modification which significantly reduced airborne contamination. Air contamination was measured while ventilating 122 patients. The modified technique reduced air contamination by a mean value of 64% (p = 0.028) compared with the standard control technique. Additionally, differences in contamination were examined when a mask or mouthpiece was used as well as differences between operators. A simplified method of monitoring air contamination is presented using a commonly available surface contamination monitor. The index so derived was proportional to air contamination (r = 0.88). The problems and regulations associated with airborne contamination are discussed.
Mid-infrared reflectlance spectra (2.3-22 micions) of sulfur, gold, KBr, MgO, and halon
NASA Technical Reports Server (NTRS)
Nash, D. B.
1986-01-01
Biconical diffuse reflectance spectra in the mid-infrared are presented for powder and other solid forms of sulfur, gold, potassium bromide, magnesium oxide, and halon. Comparisons are made with previously published results of other investigators, and recommendations are made regarding the relative usefulnees of these materials as reflectance standards in the mid-IR. Sulfur has strong intrinsic bands at wavelengths greater than 7 microns that must be taken into account for its use as a reflectance standard. Some sulfur samples have hydrocarbon contaminants and in powder form may have adsorbed water, both of which produce bands in the 3-4-micron region. Potassium bromide has several weak intrinsic bands and is very sensitive to adsorbed water contamination; otherwise it is a good IR reference material. Magnesium oxide and halon have major bands structure and low reflectivity at wavelengths greater than 2.6 microns and thus are unsuitable as reference materials in the mid-IR. Vapor-deposited gold on fine sandpaper (600 grit) is very bright, spectrally flat, and fairly diffuse, so it is the superior material (of those examined) for reflectance reference material throughout the IR. Fine gold powder, on the other hand, is much less bright than evaporated gold, and its reflectivity at wavelengths greater than its particle size is highly sensitive to particle packing density.
Różańska, Anna; Chmielarczyk, Agnieszka; Romaniszyn, Dorota; Sroka-Oleksiak, Agnieszka; Bulanda, Małgorzata; Walkowicz, Monika; Osuch, Piotr; Knych, Tadeusz
2017-01-01
Background: Hospital equipment made from copper alloys can play an important role in complementing traditional methods of disinfection. Aims of the study: The aim of this study was to assess the dynamics of the antimicrobial properties of selected copper alloys in different simulations of environmental conditions (with organic contamination vs. without organic contamination), and to test alternatives to the currently used testing methods. Materials and Methods: A modification of Japanese standard JIS Z 2801 as well as Staphylococcus aureus (SA) and Escherichia coli (EC) suspended in NaCl vs. tryptic soy broth (TSB) were used in tests performed on seven commonly used copper alloys, copper, and stainless steel. Results: A much faster reduction of the bacterial suspension was observed for the inoculum prepared in NaCl than in TSB. A faster reduction for EC than for SA was observed in the inoculum prepared in NaCl. The opposite results were found for the inoculum based on TSB. A significant correlation between the copper concentration in the copper alloys and the time and degree of bacterial suspension reduction was only observed in the case of EC. Conclusions: This study confirmed the antimicrobial properties of copper alloys, and additionally showed that Staphylococcus aureus was more resistant than Escherichia coli in the variant of the experiment without organic contamination. However, even for SA, a total reduction of the bacterial inoculum’s density took no longer than 2 h. Under conditions simulating organic contamination, all of the tested alloys were shown to have bactericidal or bacteriostatic properties, which was contrary to the results from stainless steel. PMID:28726753
An approach for addressing hard-to-detect hot spots.
Abelquist, Eric W; King, David A; Miller, Laurence F; Viars, James A
2013-05-01
The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) survey approach is comprised of systematic random sampling coupled with radiation scanning to assess acceptability of potential hot spots. Hot spot identification for some radionuclides may not be possible due to the very weak gamma or x-ray radiation they emit-these hard-to-detect nuclides are unlikely to be identified by field scans. Similarly, scanning technology is not yet available for chemical contamination. For both hard-to-detect nuclides and chemical contamination, hot spots are only identified via volumetric sampling. The remedial investigation and cleanup of sites under the Comprehensive Environmental Response, Compensation, and Liability Act typically includes the collection of samples over relatively large exposure units, and concentration limits are applied assuming the contamination is more or less uniformly distributed. However, data collected from contaminated sites demonstrate contamination is often highly localized. These highly localized areas, or hot spots, will only be identified if sample densities are high or if the environmental characterization program happens to sample directly from the hot spot footprint. This paper describes a Bayesian approach for addressing hard-to-detect nuclides and chemical hot spots. The approach begins using available data (e.g., as collected using the standard approach) to predict the probability that an unacceptable hot spot is present somewhere in the exposure unit. This Bayesian approach may even be coupled with the graded sampling approach to optimize hot spot characterization. Once the investigator concludes that the presence of hot spots is likely, then the surveyor should use the data quality objectives process to generate an appropriate sample campaign that optimizes the identification of risk-relevant hot spots.
Różańska, Anna; Chmielarczyk, Agnieszka; Romaniszyn, Dorota; Sroka-Oleksiak, Agnieszka; Bulanda, Małgorzata; Walkowicz, Monika; Osuch, Piotr; Knych, Tadeusz
2017-07-20
Background: Hospital equipment made from copper alloys can play an important role in complementing traditional methods of disinfection. Aims of the study: The aim of this study was to assess the dynamics of the antimicrobial properties of selected copper alloys in different simulations of environmental conditions (with organic contamination vs. without organic contamination), and to test alternatives to the currently used testing methods. Materials and Methods: A modification of Japanese standard JIS Z 2801 as well as Staphylococcus aureus (SA) and Escherichia coli (EC) suspended in NaCl vs. tryptic soy broth (TSB) were used in tests performed on seven commonly used copper alloys, copper, and stainless steel. Results: A much faster reduction of the bacterial suspension was observed for the inoculum prepared in NaCl than in TSB. A faster reduction for EC than for SA was observed in the inoculum prepared in NaCl. The opposite results were found for the inoculum based on TSB. A significant correlation between the copper concentration in the copper alloys and the time and degree of bacterial suspension reduction was only observed in the case of EC. Conclusions: This study confirmed the antimicrobial properties of copper alloys, and additionally showed that Staphylococcus aureus was more resistant than Escherichia coli in the variant of the experiment without organic contamination. However, even for SA, a total reduction of the bacterial inoculum's density took no longer than 2 h. Under conditions simulating organic contamination, all of the tested alloys were shown to have bactericidal or bacteriostatic properties, which was contrary to the results from stainless steel.
Davis, Jerri V.; Richards, Joseph M.
2002-01-01
In 1998, an 8-mile reach of the Jacks Fork was included on Missouri?s list of impaired waters as required by Section 303(d) of the Federal Clean Water Act. The identified pollutant on the Jacks Fork was fecal coliform bacteria. Potential sources of fecal contamination to the Jacks Fork include a wastewater treatment plant; campground pit-toilet or septic-system effluent; a large commercial, cross-country horseback trail riding facility; canoeists, boaters, and tubers; and cows.The U.S. Geological Survey, in cooperation with the National Park Service, conducted a study to better understand the extent and sources of microbiological contamination within the Jacks Fork from Alley Spring to the mouth, which includes the 8-mile 303(d) reach. Identification of the sources would provide the National Park Service and the State of Missouri with the information needed to craft a solution of abatement, regulation, prevention, and mitigation with the end result being the removal of the Jacks Fork from the 303(d) list. Fifteen sites were sampled from November 1999 through December 2000. An additional site was sampled one time. Samples were collected mostly during base-flow conditions during a variety of nonrecreational and recreational season river uses. Samples were analyzed for selected fecal indicator bacteria, physical properties, nutrients, and wastewater organic compounds. During the sampling period, the whole-body-contact recreation standard for fecal coliform (200 colonies per 100 milliliters of sample) was exceeded at three sites on August 10, 2000, and also at one site on May 11, June 7, and October 3, 2000. Fecal coliform densities and instantaneous loads generally increased from background concentrations at the Eminence site, peaked about 2 river miles downstream, and then decreased until the most downstream site sampled. Generally, the largest densities and loads at sites downstream from Eminence not related to wet-weather flow were observed during a trail ride held August 6 to12, 2000. A 24-hour sample collection effort was conducted the weekend of July 15 and 16, 2000, to investigate the effect that large numbers of swimmers, canoeists, and tubers had on fecal coliform densities in the Jacks Fork. Five or six samples were collected at six sites between Saturday morning and the following Sunday afternoon. No fecal coliform density at any of the sites sampled exceeded the whole-body-contact recreation standard. Because bacteria survive longer in stream-bed sediments than in water, a source of bacteria in the water column could be from resuspension of accumulated bacteria from streambed sediments. Water and streambed-sediment samples were collected at three sites on August 3, 2000, 1 week before a trail ride and again at three sites on 2 Assessment of Possible Sources of Microbiological Contamination of the Jacks Fork, Missouri?Phase II August 8, 2000, during a trail ride. Results indicate that fecal coliform bacteria densities increased substantially in the streambed sediment and the water column during the trail ride.Sixty-five Escherichia coli isolates obtained from water samples collected at 9 sites and 23 Escherichia coli isolates obtained from stream-bed-sediment samples collected at 5 sites were submitted for ribotyping analysis. Samples were collected in 2000 during a variety of nonrecreational and recreational season river uses, including trail rides, canoeing, tubing, and swimming. Of the 65 isolates from water samples, 40 percent were identified as originating from sewage, 29 percent from horse, 11 percent from cow, and 20 percent from an unknown source. Of the 23 isolates from streambed-sediment samples, 39 percent were identified as originating from sewage, 35 percent from horse, 13 percent from cow, and 13 percent from unknown sources.Analysis of physical property (dissolved oxygen, pH, specific conductance, and temperature) and nutrient (dissolved nitrite plus nitrate and total phosphorus) data
41 CFR 109-42.1102-51 - Suspect personal property.
Code of Federal Regulations, 2010 CFR
2010-07-01
... radioactive or chemical contamination may occur shall be considered suspect and shall be monitored using... the level of contamination of excess or surplus personal property to the lowest practicable level. Contaminated personal property that exceeds applicable contamination standards shall not be utilized or...
Selecting Performance Reference Compounds (PRCS) for Low Density Polyethylene Passive Samplers
Use of equilibrium passive samplers for performing aquatic environmental monitoring at contaminated sites is becoming more common. However, a current challenge in passive sampling is determining when equilibrium is achieved between the sampler, target contaminants, and environm...
21 CFR 120.6 - Sanitation standard operating procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... garments; (3) Prevention of cross contamination from insanitary objects to food, food packaging material... health conditions that could result in the microbiological contamination of food, food packaging... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sanitation standard operating procedures. 120.6...
Slonecker, E. Terrence; Fisher, Gary B.
2014-01-01
Operational problems with site access and information, XRF instrument operation, and imagery collections hampered the effective data collection and analysis process. Of the 24 sites imaged and analyzed, 17 appeared to be relatively clean with no discernible metal contamination, hydrocarbons, or asbestos in the soil. None of the samples for the sites in Louisiana had any result exceeding the appropriate industrial or residential standard for arsenic or lead. One site in South Carolina (North Street Dump) had two samples that exceeded the residential standard for lead. One site in Texas (Cadiz Street), and four sites in Florida (210 North 12th Street, Encore Retail Site, Clearwater Auto, and 22nd Street Mixed Use) were found to have some level of residual metal contamination above the applicable residential or commercial Risk-Based Concentration (RBC) standard. Three of the Florida sites showing metal contamination also showed a pattern of vegetation stress based on standard vegetation analysis techniques.
The Aerogel Mesh Contamination Collector
1993-07-01
patent pending 2.1 Introduction The new method of contamination prevention and collection described herein employs ultra-low density silica aerogel and a... silica aerogel and the Section 2.2 presents the fabrication of the acrogel me:sh contamination collector (AMCC). The device is a heterostructure...monolithic photonic devices and lightweight optics). This report series will focus on silica aerogels almost exclusively. It is also of interest to note that
Tang, Vera A; Renner, Tyler M; Fritzsche, Anna K; Burger, Dylan; Langlois, Marc-André
2017-12-19
Retroviruses and small EVs overlap in size, buoyant densities, refractive indices and share many cell-derived surface markers making them virtually indistinguishable by standard biochemical methods. This poses a significant challenge when purifying retroviruses for downstream analyses or for phenotypic characterization studies of markers on individual virions given that EVs are a major contaminant of retroviral preparations. Nanoscale flow cytometry (NFC), also called flow virometry, is an adaptation of flow cytometry technology for the analysis of individual nanoparticles such as extracellular vesicles (EVs) and retroviruses. In this study we systematically optimized NFC parameters for the detection of retroviral particles in the range of 115-130 nm, including viral production, sample labeling, laser power and voltage settings. By using the retroviral envelope glycoprotein as a selection marker, and evaluating a number of fluorescent dyes and labeling methods, we demonstrate that it is possible to confidently distinguish retroviruses from small EVs by NFC. Our findings make it now possible to individually phenotype genetically modified retroviral particles that express a fluorescent envelope glycoprotein without removing EV contaminants from the sample.
Microbiological quality of Puget Sound Basin streams and identification of contaminant sources
Embrey, S.S.
2001-01-01
Fecal coliforms, Escherichia coli, enterococci, and somatic coliphages were detected in samples from 31 sites on streams draining urban and agricultural regions of the Puget Sound Basin Lowlands. Densities of bacteria in 48 and 71 percent of the samples exceeded U.S. Environmental Protection Agency's freshwater recreation criteria for Escherichia coli and enterococci, respectively, and 81 percent exceeded Washington State fecal coliform standards. Male-specific coliphages were detected in samples from 15 sites. Male-specific F+RNA coliphages isolated from samples taken at South Fork Thornton and Longfellow Creeks were serotyped as Group II, implicating humans as potential contaminant sources. These two sites are located in residential, urban areas. F+RNA coliphages in samples from 10 other sites, mostly in agricultural or rural areas, were serotyped as Group I, implicating non-human animals as likely sources. Chemicals common to wastewater, including fecal sterols, were detected in samples from several urban streams, and also implicate humans, at least in part, as possible sources of fecal bacteria and viruses to the streams.
Poultry, pig and the risk of BSE following the feed ban in France--a spatial analysis.
Abrial, David; Calavas, Didier; Jarrige, Nathalie; Ducrot, Christian
2005-01-01
A spatial analysis was carried out in order to analyse the reason why the risk of Bovine Spongiform Encephalopathy (BSE) was spatially heterogeneous in France, during the period following the feed ban of Meat and Bone Meal to cattle. The hypothesis of cross-contamination between cattle feedstuff and monogastric feedstuff, which was strongly suggested from previous investigations, was assessed, with the assumption that the higher the pig or poultry density is in a given area, the higher the risk of cross-contamination and cattle infection might be. The data concerned the 467 BSE cases born in France after the ban of meat and bone meal (July 1990) and detected between July 1st, 2001 and December 31, 2003, when the surveillance system was optimal and not spatially biased. The disease mapping models were elaborated with the Bayesian graphical modelling methods and based on a Poisson distribution with spatial smoothing (hierarchical approach) and covariates. The parameters were estimated by a Markov Chain Monte Carlo simulation method. The main result was that the poultry density did not significantly influence the risk of BSE whereas the pig density was significantly associated with an increase in the risk of 2.4% per 10 000 pigs. The areas with a significant pig effect were located in regions with a high pig density as well as a high ratio of pigs to cattle. Despite the absence of a global effect of poultry density on the BSE risk, some areas had a significant poultry effect and the risk was better explained in some others when considering both pig and poultry densities. These findings were in agreement with the hypothesis of cross-contamination, which could take place at the feedstuff factory, during the shipment of food or on the farm. Further studies are needed to more precisely explore how the cross-contamination happened.
Development of standards for evaluating the importance of contaminants environment
Canfield, T.J.; Ingersold, C.G.
2003-01-01
Development of standards for evaluating the importance of contaminants environment was discussed. Committee E47 provided a forum for scientists and managers to meet twice yearly to debate and discuss approaches for conducting tests. The future for continued interactions between ASTM and EPA looked bright.
EVALUATION OF TECHNOLOGIES FOR IN SITU CLEANUP OF DNAPL CONTAMINATED SITES
Ground-water contamination by nonaqueous phase liquids poses one of the greatest remedial challenges In the field of environmental engineering. Denser-than-water nonaqueous phase liquids (DNAPLs) are especially problematic due to their tow water solubility, high density, and capi...
Code of Federal Regulations, 2011 CFR
2011-01-01
... fumigation of cotton and covers (other than high density cotton free of surface contamination) will be... only lint, linters, or waste, and the bales of which are compressed to a density of 28 or more pounds...
Learn About the Unregulated Contaminant Monitoring Rule
EPA uses the Unregulated Contaminant Monitoring program to collect data for contaminants suspected to be present in drinking water, but that do not have health-based standards set under the Safe Drinking Water Act (SDWA)
Drinkable, But. . . Much to be Done
ERIC Educational Resources Information Center
Sterrett, Frances S.
1977-01-01
Maximum levels of the principle water contaminants are discussed in this article. Difficulties related to establishing standards for contaminants in drinking water are identified and the possible results of high levels of these contaminants included. (MA)
41 CFR 109-42.1102-52 - Low level contaminated personal property.
Code of Federal Regulations, 2010 CFR
2010-07-01
... contamination does not exceed applicable standards, it may be utilized and disposed of in the same manner as.... However, recipients shall be advised where levels of radioactive contamination require specific controls... within DOE, reported to GSA, or otherwise disposed of, the kind and degree of contamination must be...
9 CFR 113.30 - Detection of Salmonella contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...
9 CFR 113.30 - Detection of Salmonella contamination.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...
NASA Astrophysics Data System (ADS)
Rackham, Benjamin V.; Apai, Dániel; Giampapa, Mark S.
2018-02-01
Transmission spectra are differential measurements that utilize stellar illumination to probe transiting exoplanet atmospheres. Any spectral difference between the illuminating light source and the disk-integrated stellar spectrum due to starspots and faculae will be imprinted in the observed transmission spectrum. However, few constraints exist for the extent of photospheric heterogeneities in M dwarfs. Here we model spot and faculae covering fractions consistent with observed photometric variabilities for M dwarfs and the associated 0.3–5.5 μm stellar contamination spectra. We find that large ranges of spot and faculae covering fractions are consistent with observations and corrections assuming a linear relation between variability amplitude, and covering fractions generally underestimate the stellar contamination. Using realistic estimates for spot and faculae covering fractions, we find that stellar contamination can be more than 10× larger than the transit depth changes expected for atmospheric features in rocky exoplanets. We also find that stellar spectral contamination can lead to systematic errors in radius and therefore the derived density of small planets. In the case of the TRAPPIST-1 system, we show that TRAPPIST-1's rotational variability is consistent with spot covering fractions {f}{spot}={8}-7+18 % and faculae covering fractions {f}{fac}={54}-46+16 % . The associated stellar contamination signals alter the transit depths of the TRAPPIST-1 planets at wavelengths of interest for planetary atmospheric species by roughly 1–15× the strength of planetary features, significantly complicating JWST follow-up observations of this system. Similarly, we find that stellar contamination can lead to underestimates of the bulk densities of the TRAPPIST-1 planets of {{Δ }}(ρ )=-{8}-20+7 % , thus leading to overestimates of their volatile contents.
Gohar, Maha Kamal; Atta, Amal Hassan
2016-01-01
Fecal contamination of drinking water is a major health problem which accounts for many cases of diarrhea mainly in infants and foreigners. This contamination is a complex interaction of many parameters. Antibiotic resistance among bacterial isolates complicates the problem. The study was done to identify fecal contamination of drinking water by Diarrheagenic Antibiotic-Resistant Escherichia coli in Zagazig city and to trace reasons for such contamination, three hundred potable water samples were investigated for E. coli existence. Locations of E. coli positive samples were investigated in relation to population density, water source, and type of water pipe. Sixteen E. coli strains were isolated. Antibiotic sensitivity was done and enterotoxigenic, enteropathogenic, and enterohaemorrhagic virulence genes were investigated by PCR. Probability of fecal contamination correlated with higher population density, with increased distance from Zagazig water plant, and with asbestos cement water pipes. Resistance to at least one antimicrobial drug was found in all isolates. Virulence genes were detected in a rate of 26.27%, 13.13%, 20%, 6.67%, and 33.33% for LT, ST, stx1, stx2, and eae genes, respectively. This relatively high frequency of fecal contamination points towards the high risk of developing diarrhea by antibiotic resistant DEC in low socioeconomic communities particularly with old fashion distribution systems. PMID:27725834
Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device
Cavalieri, R. Jennifer; Marolf, Cole; Lyden, Elizabeth
2017-01-01
Abstract Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5–2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. Clinical Trials Registration. NCT02102087. PMID:28379370
The Contamination of the Effective Schools Movement (Guest Column).
ERIC Educational Resources Information Center
Thomas, M. Donald; Bainbridge, William L.
2001-01-01
The effective-schools movement as currently promoted by profit-oriented consultants has been contaminated by five fallacies: all children have equal learning opportunities; principals (not teachers) are instructional leaders; standards should be set by exceptions; academic standards should be uniform; and teachers should work smarter, not harder.…
NASA Astrophysics Data System (ADS)
Park, Yongkook
This thesis examines the electrical properties of grain boundaries (GBs) and dislocations in crystalline silicon. The influence of impurity incorporation and hydrogenation on the electrical properties of grain boundaries , as well as the electrical activity of impurity decorated dislocations and the retention of impurities at dislocations at high temperatures have been investigated. The electrical properties of Si GB were examined by C-V, J-V , and capacitance transient methods using aluminum/Si(100)/Si(001) junctions. First, the density of states and the carrier capture cross-sections of the clean GB were evaluated by C-V/J-V analyses. The density of GB states was determined as 4.0x1012 cm-2eV -1. It was found that the states close to the valance band edge have relatively smaller hole capture cross sections than those at higher energy position, and electron capture cross sections are at least two or three orders larger than the corresponding hole capture cross sections. Secondly, the influence of iron contamination and hydrogenation following iron contamination on the electrical properties of (110)/(001) Si GB was characterized by a capacitance transient technique. Compared with the clean sample, iron contamination increased both the density of states by at least three times and the zero-bias barrier height by 70 meV, while reducing by two orders of magnitude the electron/hole capture cross-section ratio. Hydrogenation following iron contamination led to the reduction of the density of Fe-decorated GB states, which was increased to over 2x1013 cm-2eV-1 after iron contamination, to ˜1x1013 cm-2 eV-1 after hydrogenation treatment. The increased zero-bias GB energy barrier due to iron contamination was reversed as well by hydrogen treatment. The density of GB states before and after hydrogenation was evaluated by J-V, C-V and capacitance transient methods using gold/direct-silicon-bonded (DSB) (110) thin silicon top layer/(100) silicon substrate junctions. The GB potential energy barrier in thermal equilibrium was reduced by 70 meV. Whereas the clean sample had a density of GB states of ˜6x1012 cm-2eV-1 in the range of Ev+0.54˜0.64 eV, hydrogenation reduced the density of GB states to ˜9x1011 cm-2eV -1 in the range of Ev+0.56˜0.61 eV, which is about a seven-fold reduction from that of the clean sample. Segregation and thermal dissociation kinetics of hydrogen at a large-angle general GB in crystalline silicon have been investigated using deuterium as a readily identifiable isotope which duplicates hydrogen chemistry. Segregation or trapping of deuterium (hydrogen) introduced was found to take place at (110)/(001) Si GB. The segregation coefficient (k) of deuterium (hydrogen) at GB was determined as k≈24+/-3 at 100°C. Thermal dissociation of deuterium (hydrogen) from GB obeyed first-order kinetics with an activation energy of ˜1.62 eV. The electrical activities of dislocations in a SiGe/Si heterostructure were examined by deep level transient spectroscopy (DLTS) after iron contamination and phosphorous diffusion gettering. DLTS of iron contaminated samples revealed a peak at 210 K, which was assigned to individual iron atoms or very small (<2 nm) precipitates decorated along dislocations. Arrhenius plot of the 210 K peak yielded a hole capture cross section of 2.4x10-14 cm2 and an energy level of 0.42 eV above the valance band. DLTS of the iron contaminated sample revealed that 6x10 14 cm-3 of boron can more effectively trap interstitial iron at room temperature than the strain field/defect sites at 107 ˜108 cm-2 dislocations. Phosphorous diffusion experiments revealed that the gettering efficiency of iron impurities depends on the dislocation density. For regions of high dislocation density, phosphorous diffusion cannot remove all iron impurities decorated at dislocations, suggesting a strong binding of iron impurities at dislocation core defects.
SUPERCRITICAL FLUID EXTRACTION OF POLYCYCLIC AROMATIC HYDROCARBON MIXTURES FROM CONTAMINATED SOILS
Highly contaminated (with PAHs) topsoils were extracted with supercritical CO2 to determine the feasibility and mechanism of supercritical fluid extraction (SFE). Effect of SCF density, temperature, cosolvent type and amount, and of slurrying the soil with water were ...
EVALUATION OF TECHNOLOGIES FOR IN SITU CLEANUP OF DNAPL CONTAMINATED SITES
Ground water contamination by non-aqueous phase liquids poses one of the greatest remedial challenges in the field of environmental engineering. Denser-than-water non-aqueous phase liquids (DNAPLs) are especially problematic due to their low water solubility, high density, an...
Weinstein, John E; Crawford, Kevin D; Garner, Thomas R
2010-03-01
The purpose of this study was to characterize the polycyclic aromatic hydrocarbon (PAH) contamination in the sediments of stormwater detention ponds in coastal South Carolina. Levels of the sum of PAH analytes were significantly higher in the sediments of commercial ponds compared to that of reference, golf course, low-density residential, and high-density residential ponds. Isomer ratio analysis suggested that the predominant source of PAHs were pyrogenic; however, many ponds had a PAH signature consistent with mixed uncombusted and combusted PAH sources. PAH levels in these sediments could be modeled using both pond drainage area and pond surface area. These results demonstrate that the sediment from most commercial ponds, and a few residential and golf course ponds, were moderately contaminated with PAHs. PAH levels in these contaminated ponds exceeded between 42% and 75% of the ecological screening values for individual PAH analytes established by US EPA Region IV, suggesting that they may pose a toxicological risk to wildlife.
Gern, Fabiana Regina; Lana, Paulo da Cunha
2013-02-15
Coastal benthic habitats are usually in a state of continuous recolonization as a consequence of natural disturbances or human activities. Recolonization patterns can be strongly affected by the quality of the sediment. We evaluated herein the macrobenthic recolonization of organically enriched sediments through a manipulative experiment involving reciprocal transplants between contaminated and non-contaminated intertidal areas. Regardless of the experimental treatments, the density of the polychaete Capitella sp. was extremely high in the contaminated area as well as the density of the gastropod Cylichna sp. in the non-contaminated area. We rejected the hypothesis that differences in sediment quality would determine macrofaunal recolonization at least in the considered scales of space in meters and time in weeks. The recolonization process in a subtropical estuarine environment was strongly dependent on the migration of adults present in the sediments adjacent to the experimental units. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sidhu, K.S.
1991-06-01
The primary objective of a standard setting process is to arrive at a drinking water concentration at which exposure to a contaminant would result in no known or potential adverse health effect on human health. The drinking water standards also serve as guidelines to prevent pollution of water sources and may be applicable in some cases as regulatory remediation levels. The risk assessment methods along with various decision making parameters are used to establish drinking water standards. For carcinogens classified in Groups A and B by the United States Environmental Protection Agency (USEPA) the standards are set by using nonthresholdmore » cancer risk models. The linearized multistage model is commonly used for computation of potency factors for carcinogenic contaminants. The acceptable excess risk level may vary from 10(-6) to 10(-4). For noncarcinogens, a threshold model approach based on application of an uncertainty factor is used to arrive at a reference dose (RfD). The RfD approach may also be used for carcinogens classified in Group C by the USEPA. The RfD approach with an additional uncertainty factory of 10 for carcinogenicity has been applied in the formulation of risk assessment for Group C carcinogens. The assumptions commonly used in arriving at drinking water standards are human life expectancy, 70 years; average human body weight, 70 kg; human daily drinking water consumption, 2 liters; and contribution of exposure to the contaminant from drinking water (expressed as a part of the total environmental exposure), 20%. Currently, there are over 80 USEPA existing or proposed primary standards for organic and inorganic contaminants in drinking water. Some of the state versus federal needs and viewpoints are discussed.« less
Occurrence Data for the Unregulated Contaminant Monitoring Rule
EPA uses the Unregulated Contaminant Monitoring Rule (UCMR) to collect data for contaminants suspected to be present in drinking water, but that do not have health-based standards set under the Safe Drinking Water Act (SDWA)
Wise, Stephen A; Poster, Dianne L; Kucklick, John R; Keller, Jennifer M; Vanderpol, Stacy S; Sander, Lane C; Schantz, Michele M
2006-10-01
For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).
The impact of on-site wastewater from high density cluster developments on groundwater quality
NASA Astrophysics Data System (ADS)
Morrissey, P. J.; Johnston, P. M.; Gill, L. W.
2015-11-01
The net impact on groundwater quality from high density clusters of unsewered housing across a range of hydro(geo)logical settings has been assessed. Four separate cluster development sites were selected, each representative of different aquifer vulnerability categories. Groundwater samples were collected on a monthly basis over a two year period for chemical and microbiological analysis from nested multi-horizon sampling boreholes upstream and downstream of the study sites. The field results showed no statistically significant difference between upstream and downstream water quality at any of the study areas, although there were higher breakthroughs in contaminants in the High and Extreme vulnerability sites linked to high intensity rainfall events; these however, could not be directly attributed to on-site effluent. Linked numerical models were then built for each site using HYDRUS 2D to simulate the attenuation of contaminants through the unsaturated zone from which the resulting hydraulic and contaminant fluxes at the water table were used as inputs into MODFLOW MT3D models to simulate the groundwater flows. The results of the simulations confirmed the field observations at each site, indicating that the existing clustered on-site wastewater discharges would only cause limited and very localised impacts on groundwater quality, with contaminant loads being quickly dispersed and diluted downstream due to the relatively high groundwater flow rates. Further simulations were then carried out using the calibrated models to assess the impact of increasing cluster densities revealing little impact at any of the study locations up to a density of 6 units/ha with the exception of the Extreme vulnerability site.
Hayes, Galina; Singh, Ameet; Gibson, Tom; Moens, Noel; Oblak, Michelle; Ogilvie, Adam; Reynolds, Debbie
2017-10-01
To determine the influence of orthopedic reinforced gloves on contamination events during small animal orthopedic surgery. Prospective randomized controlled trial SAMPLE POPULATION: Two hundred and thirty-seven pairs of orthopedic gloves (474 gloves) and 203 pairs of double standard gloves (812 gloves) worn during 193 orthopedic procedures. Primary and assistant surgeons were randomized to wear either orthopedic reinforced gloves or double gloves. Gloves were leak tested to identify perforations at the end of procedures. Perforations detected intraoperatively or postoperatively were recorded. A contamination event was defined as at least one perforation on either hand for orthopedic reinforced gloves, or a perforation of both the inner and outer glove on the same hand for double gloves. Baseline characteristics between the 2 intervention groups were similar. There was no difference in contamination events between the double-gloved and orthopedic gloved groups (OR = 0.95, 95% CI = 0.49-1.87, P = .89). The same percentage of contamination events (8% glove pairs used) occurred in the double gloved group (17 contamination events) and in the orthopedic gloved group (19 contamination events). The odds of a contamination event increased by 1.02 (95% CI 1.01-1.03, P < .001) with each additional minute of surgery. Orthopedic reinforced gloves and double standard gloving were equally effective at preventing contamination events in small animal orthopedic procedures. Surgeons reluctant to double glove due to perceptions of decreased dexterity and discomfort may safely opt for wearing orthopedic gloves, which may improve their compliance. © 2017 The American College of Veterinary Surgeons.
Decontaminating the DOE-STD-3013 Inner Container to Meet 10-CFR-835 Appendix D Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, H.E.; Nelson, T.O.; Rivera, Y.M.
The United States Department of Energy (DOE) has published a standard that specifies the criteria for preparation and packaging of plutonium metals and oxides for safe long-term storage (DOE-STD-3013-96). This standard is followed for the packaging of materials resulting from the disassembly of nuclear weapons at Los Alamos National Laboratory under the Advanced Retirement and Integrated Extraction System (ARIES) project. Declassified plutonium metal or oxide material from the ARES project is packaged into doubly contained and welded type 304L stainless steel containers that comply with the DOE standard. The 3013-96 standard describes requirements for maximum contamination limits on the outermore » surface of the sealed inner container. These limits are 500 dpm per 100 cm2 for direct measurements and 20 dpm per 100 cm2 for removable contamination. For containers filled, welded, and handled inside a highly contaminated glovebox line, these limits are difficult to obtain. Simple handling within the line is demonstrated to contaminate surfaces from 10,000 to 10,000,000 dpm alpha per 100 cm2. To routinely achieve contamination levels below the maximum contamination levels specified by the 3013-96 standard within a processing operation, a decontamination step must be included. In the ARIES line, this decontamination step is an electrolytic process that produces a controlled uniform etch of the container surfaces. Decontamination of the 3013-96 compliant ARIES inner container is well demonstrated. Within 30 to 50 minutes electrolysis time, tixed contamination is reduced to hundreds of dpm generally occurring only at electrode contact points and welds. Removable contamination is routinely brought to non-detectable levels. The total process time for the cycle (includes electrolysis, rinse, and dry stages) is on the order of 1.5 to 2 hours per container. The ARIES inner container decontamination system highly automated and consists of a plumbing loop, electronic controls and process monitors, and a decontamination chamber or "fixture". The tixture is situated like an air lock between a contaminated and an uncontaminated section of a processing glovebox. The welded and leak tested container is placed into the fixture through a door on the contaminated side and the electrolysis process is run, including rinse and dry cycles. The container is then removed through a second door into the uncontaminated side where it is monitored for surface alpha contamination, leak checked, and reweighed.« less
Strauss, Rachel A; Genschel, Ulrike; Allbaugh, Rachel A; Sebbag, Lionel; Ben-Shlomo, Gil
2018-05-24
To investigate microbial contamination of canine plasma eye drops when used clinically and to compare the effect of two different eyedropper bottles on contamination rate. Forty-six bottles containing plasma were randomly dispensed for use on 42 dogs with ulcerative keratitis. Of these, 23 were standard eyedropper bottles and 23 were Novelia ® bottles designed to prevent contamination. After use for up to 2 weeks, samples for bacterial culture were obtained from a drop of plasma, the bottle tip, the plasma inside the bottle, and the corneal surface. Fungal culture was performed from a drop of plasma. The overall microbial contamination rate was 17.4% (8/46 bottles); however, only one bottle had growth from the plasma inside the bottle. There was a lower contamination rate of Novelia ® bottles (3/23 = 13.0%) compared to standard bottles (5/23 = 21.7%), but this difference was not statistically significant (P = .57). There were also no significant differences in contamination rate of bottles used greater than 7 days compared to less than or equal to 7 days, or in bottles used greater than 4 times daily compared to 4 times daily or less. Three corneal samples (6.5%) had bacterial growth, but none matched contamination from the bottles. Novelia ® bottles may decrease contamination of plasma eye drops used clinically. However, while microbial contamination of plasma bottles was documented, no clinically relevant complications were observed. This study supports safe use of plasma eye drops for up to 2 weeks when refrigerated and dispensed from either Novelia ® or standard eyedropper bottles. © 2018 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Kang, Kyoung Ho; Zhang, Zhifeng; Kim, Jae Min; Seon, Seung Chun; Shao, Mingyu
2010-03-01
Biological activities of marine benthos such as burrowing and feeding may change sediment characteristics. We conducted three experiments to examine the potential of using juveniles of a spoon worm Urechis unicinctus to improve the quality of organically contaminated coastal sediment. Sediment samples were collected from a site that was heavily contaminated with organic matter (Seonso) and two sites that were clean (Myo-do, Dolsan-do). Urechis juveniles, obtained by artificial fertilization and cultured in the laboratory, were introduced to the sediment (weight 3 kg, depth 10 cm) at a density of 500 individuals per aquarium (length 50 cm, width 35 cm, height 30 cm) (Experiment 1), or at densities ranging from 100 to 900 individuals per beaker (Experiment 2). To examine how sediment contamination can be modified by the effects of Urechis, 500 individuals (per aquarium) were exposed to the Seonso contaminated sediment that had been mixed with 0-100% clean sand (Experiment 3). Each experiment lasted two months and sediment samples were collected every 15 d to determine the several indexes of sediment quality, which included acid volatile sulfide (AVS), chemical oxygen demand (COD) and total ignition loss (TIL). In Experiment 1, the existence of Urechis did not result in significant changes in quality indexes in the sediments collected from Myo-do, Dolsan-do. However, AVS, COD and TIL of the Seonso sediment all decreased significantly after co-incubation with Urechis juveniles for 30 to 45 d. Experiment 2 showed that a density of at least 300 juveniles per beaker was necessary to significantly reduce all three quality indexes, and the magnitude of reduction was positively correlated with juvenile density. Experiment 3 revealed that Urechis juveniles were effective in reducing the AVS, COD and TIL of the Seonso sediment that had been mixed with 60%, 80%, and 80% of clean sand, respectively. The results of the present study therefore indicated that juveniles of this spoon worm have the potential to be used to improve the quality of organically contaminated sediment in coastal waters.
Bradley, Joseph A; Yang, Ping; Batista, Enrique R; Boland, Kevin S; Burns, Carol J; Clark, David L; Conradson, Steven D; Kozimor, Stosh A; Martin, Richard L; Seidler, Gerald T; Scott, Brian L; Shuh, David K; Tyliszczak, Tolek; Wilkerson, Marianne P; Wolfsberg, Laura E
2010-10-06
Accurate X-ray absorption spectra (XAS) of first row atoms, e.g., O, are notoriously difficult to obtain due to the extreme sensitivity of the measurement to surface contamination, self-absorption, and saturation affects. Herein, we describe a comprehensive approach for determining reliable O K-edge XAS data for ReO(4)(1-) and provide methodology for obtaining trustworthy and quantitative data on nonconducting molecular systems, even in the presence of surface contamination. This involves comparing spectra measured by nonresonant inelastic X-ray scattering (NRIXS), a bulk-sensitive technique that is not prone to X-ray self-absorption and provides exact peak intensities, with XAS spectra obtained by three different detection modes, namely total electron yield (TEY), fluorescence yield (FY), and scanning transmission X-ray microscopy (STXM). For ReO(4)(1-), TEY measurements were heavily influenced by surface contamination, while the FY and STXM data agree well with the bulk NRIXS analysis. These spectra all showed two intense pre-edge features indicative of the covalent interaction between the Re 5d and O 2p orbitals. Density functional theory calculations were used to assign these two peaks as O 1s excitations to the e and t(2) molecular orbitals that result from Re 5d and O 2p covalent mixing in T(d) symmetry. Electronic structure calculations were used to determine the amount of O 2p character (%) in these molecular orbitals. Time dependent-density functional theory (TD-DFT) was also used to calculate the energies and intensities of the pre-edge transitions. Overall, under these experimental conditions, this analysis suggests that NRIXS, STXM, and FY operate cooperatively, providing a sound basis for validation of bulk-like excitation spectra and, in combination with electronic structure calculations, suggest that NaReO(4) may serve as a well-defined O K-edge energy and intensity standard for future O K-edge XAS studies.
Pinturaud, Marine; Soichot, Marion; Richeval, Camille; Humbert, Luc; Lebecque, Michèle; Sidikou, Ousseini; Barthelemy, Christine; Bonnabry, Pascal; Allorge, Delphine; Décaudin, Bertrand; Odou, Pascal
2016-01-01
Background The objective of this randomized, prospective and controlled study was to investigate the ability of a closed-system transfer device (CSTD; BD-Phaseal) to reduce the occupational exposure of two isolators to 10 cytotoxic drugs and compare to standard compounding devices. Methods and Findings The 6-month study started with the opening of a new compounding unit. Two isolators were set up with 2 workstations each, one to compound with standard devices (needles and spikes) and the other using the Phaseal system. Drugs were alternatively compounded in each isolator. Sampling involved wiping three surfaces (gloves, window, worktop), before and after a cleaning process. Exposure to ten antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-FU, methotrexate, gemcitabine, cytarabine, irinotecan, doxorubicine and ganciclovir) was assessed on wipes by LC-MS/MS analysis. Contamination rates were compared using a Chi2 test and drug amounts by a Mann-Whitney test. Significance was defined for p<0.05. Overall contamination was lower in the “Phaseal” isolator than in the “Standard” isolator (12.24% vs. 26.39%; p < 0.0001) although it differed according to drug. Indeed, the contamination rates of gemcitabine were 49.3 and 43.4% (NS) for the Standard and Phaseal isolators, respectively, whereas for ganciclovir, they were 54.2 and 2.8% (p<0.0001). Gemcitabine amounts were 220.6 and 283.6 ng for the Standard and Phaseal isolators (NS), and ganciclovir amounts were 179.9 and 2.4 ng (p<0.0001). Conclusion This study confirms that using a CSTD may significantly decrease the chemical contamination of barrier isolators compared to standard devices for some drugs, although it does not eliminate contamination totally. PMID:27391697
Nicolas, M; Alvarez, M; Borragán, S; Martinez-Pastor, F; Chamorro, C A; Alvarez-Rodriguez, M; de Paz, P; Anel, L
2012-04-01
Centrifugation is a crucial procedure in sperm cryopreservation protocols of brown bear (Ursus arctos), because the semen must be processed to increase sperm concentration and/or clean urine-contaminated samples. The efficacy of three media for centrifugation (Maxifreeze [IMV technologies, L'Aigle, France], Cushion Fluid Equine (Minitübe, Tiefenbach, Germany), and PureSperm [Nidacon, Gothenburg, Sweden]) on the quality of bear spermatozoa was evaluated. In experiment one, two cushioned media used for protecting against mechanical stress during centrifugation were analyzed. In experiment two, a density gradient based on PureSperm was assessed in relation to the maximum retrieval and the quality of fresh spermatozoa, and the freezability of the spermatozoa selected in this density gradient was studied in experiment three. Finally, the selection of frozen-thawed sperm using PureSperm was analyzed in experiment four. Our results indicate that the use of dense isotonic cushion solutions (Maxifreeze, Cushion Fluid Equine) in centrifugation did not improve the quality of recovered spermatozoa compared with standard centrifugation. However, a density gradient prepared with PureSperm improved the quality of spermatozoa in fresh semen and frozen-thawed semen, but the spermatozoa selected from the fresh sample with this density gradient did not show a better resistance to freezing with this density gradient in comparison with the control sample. Copyright © 2012 Elsevier Inc. All rights reserved.
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira
2014-01-01
To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.
Emerging contaminants: Presentations at the 2009 Toxicology and Risk Assessment Conference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murnyak, George, E-mail: George.murnyak@us.army.mil; Vandenberg, John, E-mail: Vandenberg.John@epamail.epa.gov; Yaroschak, Paul J., E-mail: Paul.Yaroschak@osd.mil
2011-07-15
A session entitled 'Emerging Contaminants' was held in April 2009 in Cincinnati, OH at the 2009 Toxicology and Risk Assessment Conference. The purpose of the session was to share information on both programmatic and technical aspects associated with emerging contaminants. Emerging contaminants are chemicals or materials that are characterized by a perceived or real threat to human health or environment, a lack of published health standards or an evolving standard. A contaminant may also be 'emerging' because of the discovery of a new source, a new pathway to humans, or a new detection method or technology. The session included fivemore » speakers representing the Department of Defense (DoD), the Environmental Protection Agency (EPA), and each of the military services. The DoD created the Emerging Contaminant Directorate to proactively address environmental, health, and safety concerns associated with emerging contaminants. This session described the scan-watch-action list process, impact assessment methodology, and integrated risk management concept that DoD has implemented to manage emerging contaminants. EPA presented emerging trends in health risk assessment. Researchers made technical presentations on the status of some emerging contaminates in the assessment process (i.e. manganese, RDX, and naphthalene).« less
NASA Astrophysics Data System (ADS)
Mao, D.; Revil, A.; Hort, R. D.; Munakata-Marr, J.; Atekwana, E. A.; Kulessa, B.
2015-11-01
Geophysical methods can be used to remotely characterize contaminated sites and monitor in situ enhanced remediation processes. We have conducted one sandbox experiment and one contaminated field investigation to show the robustness of electrical resistivity tomography and self-potential (SP) tomography for these applications. In the sandbox experiment, we injected permanganate in a trichloroethylene (TCE)-contaminated environment under a constant hydraulic gradient. Inverted resistivity tomograms are able to track the evolution of the permanganate plume in agreement with visual observations made on the side of the tank. Self-potential measurements were also performed at the surface of the sandbox using non-polarizing Ag-AgCl electrodes. These data were inverted to obtain the source density distribution with and without the resistivity information. A compact horizontal dipole source located at the front of the plume was obtained from the inversion of these self-potential data. This current dipole may be related to the redox reaction occurring between TCE and permanganate and the strong concentration gradient at the front of the plume. We demonstrate that time-lapse self-potential signals can be used to track the kinetics of an advecting oxidizer plume with acceptable accuracy and, if needed, in real time, but are unable to completely resolve the shape of the plume. In the field investigation, a 3D resistivity tomography is used to characterize an organic contaminant plume (resistive domain) and an overlying zone of solid waste materials (conductive domain). After removing the influence of the streaming potential, the identified source current density had a magnitude of 0.5 A m-2. The strong source current density may be attributed to charge movement between the neighboring zones that encourage abiotic and microbially enhanced reduction and oxidation reactions. In both cases, the self-potential source current density is located in the area of strong resistivity gradient.
Jackson, P. Ryan; Garcia, Carlos M.; Oberg, Kevin A.; Johnson, Kevin K.; Garcia, Marcelo H.
2008-01-01
Bidirectional flows in a river system can occur under stratified flow conditions and in addition to creating significant errors in discharge estimates, the upstream propagating currents are capable of transporting contaminants and affecting water quality. Detailed field observations of bidirectional flows were made in the Chicago River in Chicago, Illinois in the winter of 2005-06. Using multiple acoustic Doppler current profilers simultaneously with a water-quality profiler, the formation of upstream propagating density currents within the Chicago River both as an underflow and an overflow was observed on three occasions. Density differences driving the flow primarily arise from salinity differences between intersecting branches of the Chicago River, whereas water temperature is secondary in the creation of these currents. Deicing salts appear to be the primary source of salinity in the North Branch of the Chicago River, entering the waterway through direct runoff and effluent from a wastewater-treatment plant in a large metropolitan area primarily served by combined sewers. Water-quality assessments of the Chicago River may underestimate (or overestimate) the impairment of the river because standard water-quality monitoring practices do not account for density-driven underflows (or overflows). Chloride concentrations near the riverbed can significantly exceed concentrations at the river surface during underflows indicating that full-depth parameter profiles are necessary for accurate water-quality assessments in urban environments where application of deicing salt is common.
Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device.
Rupp, Mark E; Cavalieri, R Jennifer; Marolf, Cole; Lyden, Elizabeth
2017-07-15
Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5-2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device™ (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting. NCT02102087. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Bayesian power spectrum inference with foreground and target contamination treatment
NASA Astrophysics Data System (ADS)
Jasche, J.; Lavaux, G.
2017-10-01
This work presents a joint and self-consistent Bayesian treatment of various foreground and target contaminations when inferring cosmological power spectra and three-dimensional density fields from galaxy redshift surveys. This is achieved by introducing additional block-sampling procedures for unknown coefficients of foreground and target contamination templates to the previously presented ARES framework for Bayesian large-scale structure analyses. As a result, the method infers jointly and fully self-consistently three-dimensional density fields, cosmological power spectra, luminosity-dependent galaxy biases, noise levels of the respective galaxy distributions, and coefficients for a set of a priori specified foreground templates. In addition, this fully Bayesian approach permits detailed quantification of correlated uncertainties amongst all inferred quantities and correctly marginalizes over observational systematic effects. We demonstrate the validity and efficiency of our approach in obtaining unbiased estimates of power spectra via applications to realistic mock galaxy observations that are subject to stellar contamination and dust extinction. While simultaneously accounting for galaxy biases and unknown noise levels, our method reliably and robustly infers three-dimensional density fields and corresponding cosmological power spectra from deep galaxy surveys. Furthermore, our approach correctly accounts for joint and correlated uncertainties between unknown coefficients of foreground templates and the amplitudes of the power spectrum. This effect amounts to correlations and anti-correlations of up to 10 per cent across wide ranges in Fourier space.
77 FR 36984 - International Standard-Setting Activities
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-20
... to Reduce Contamination of Food with Chemicals. Revised definition of Contaminant. To be considered... Code of Practice for Weed Control to Prevent and Reduce Pyrolizidine Alkaloid Contamination in Food and... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2012-0017...
Brown, Christopher R.; Macy, Jamie P.
2012-01-01
Water-chemistry data for selected wells and baseflow investigations sites are presented. No well samples analyzed exceeded the U.S. Environmental Protection Agency Maximum Contaminant Level standards for drinking water, but several samples exceeded Secondary Maximum Contaminant Level standards for chloride, fluoride, sulfate, iron, and total dissolved solids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington, Aaron L.; Narrows, William; Christian, Jonathan H.
During Decommissioning and Demolition (D&D) activities at SRS, it is important that the building be screened for radionuclides and heavy metals to ensure that the proper safety and disposal metrics are in place. A major source of contamination at DOE facilities is the accumulation of mercury contamination, from nuclear material processing and Liquid Waste System (LWS). This buildup of mercury could possibly cause harm to any demolition crew or the environment should this material be released. The current standard method is to take core samples in various places in the facility and use X-ray fluorescence (XRF) to detect the contamination.more » This standard method comes with a high financial value due to the security levels of these sample facilities with unknown contamination levels. Here in we propose the use of portable XRF units to detect for this contamination on-site. To validate this method, the instrument has to be calibrated to detect the heavy metal contamination, be both precise with the known elemental concentrations and consistent with its actual results of a sample concrete and pristine contaminant, and be able to detect changes in the sample concrete’s composition. After receiving the various concrete samples with their compositions found by a XRF wave-dispersive method, the calibration factor’s linear regressions were adjusted to give the baseline concentration of the concrete with no contamination. Samples of both concrete and concrete/flyash were evaluated; their standard deviations revealed that the measurements were consistent with the known composition. Finally, the samples were contaminated with different concentrations of sodium tungsten dihydrate, allowed to air dry, and measured. When the contaminated samples were analyzed, the heavy metal contamination was seen within the spectrum of the instrument, but there was not a trend of quantification based on the concentration of the solution.« less
Contamination assessment for OSSA space station IOC payloads
NASA Technical Reports Server (NTRS)
Chinn, S.; Gordon, T.; Rantanen, R.
1987-01-01
The results are presented from a study for the Space Station Planners Group of the Office of Space Sciences and Applications. The objectives of the study are: (1) the development of contamination protection requirements for protection of Space Station attached payloads, serviced payloads and platforms; and (2) the determination of unknowns or major impacts requiring further assessment. The nature, sources, and quantitative properties of the external contaminants to be encountered on the Station are summarized. The OSSA payload contamination protection requirements provided by the payload program managers are reviewed and the level of contamination awareness among them is discussed. Preparation of revisions to the contamination protection requirements are detailed. The comparative impact of flying the Station at constant atmospheric density rather than constant altitude is assessed. The impact of the transverse boom configuration of the Station on contamination is also assessed. The contamination protection guidelines which OSSA should enforce during their development of payloads are summarized.
10 CFR 20.1406 - Minimization of contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Minimization of contamination. 20.1406 Section 20.1406 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiological Criteria for License Termination § 20.1406 Minimization of contamination. (a) Applicants for licenses, other than early...
10 CFR 20.1406 - Minimization of contamination.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Minimization of contamination. 20.1406 Section 20.1406 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiological Criteria for License Termination § 20.1406 Minimization of contamination. (a) Applicants for licenses, other than early...
Spiridonova, S I; Mukusheva, M K; Shubina, O A; Solomatin, V M; Epifanova, I E
2008-01-01
The results are presented from estimation of spatial distribution of 137Cs and 90Sr contamination densities in the areas of horses and sheep grazing within the Semipalatinsk Test Site. Dose burdens to various cohorts of the population living within the STS and consuming contaminated animal products are predicted. Doses of shepherds in the most contaminated pasture areas have been found to exceed the accepted limit (1 mSv/y). The conclusion is made about the need for further studies on the risk assessment of the STS population exposure above the accepted limits.
Optical contamination on the Atmosphere Explorer-E satellite
NASA Technical Reports Server (NTRS)
Yee, J. H.; Abreu, V. J.
1983-01-01
Atmospheric optical emission measurements by the Visible Airglow Experiment (VAE) on board the Atmosphere Explorer (AE-C, D and E) satellites have been analyzed and found to be contaminated at low altitudes. The contamination maximizes in the forward direction along the spacecraft velocity and is sensitive to the composition and density of the ambient atmosphere. Analysis at two different wavelengths suggests that the contamination is likely to have a diffuse band spectrum which is brighter toward the red. Some unknown processes which involve satellite surface materials and the incoming ambient particles are believed to be responsible for the contamination. A simulation model is presented here to account for the observed angular dependence.
[Microbiological characteristics of selected liquid soaps for hands washing].
Tyski, Stefan; Bocian, Ewa; Zawistowska, Anna; Mrówka, Agnieszka; Kruszewska, Hanna; Grzybowska, Wanda; Zareba, Tomasz
2013-01-01
According to common belief, supported by the authority of the World Health Organization - WHO, the common (social) hand washing is the simplest, cheapest and the most effective way of reduction the hospital-acquired infections. For this purpose products of"liquid soaps", present in a large number on the market, are most often applied. Microbiological status (microbiological purity and antimicrobial activity) of"liquid soaps" available on the Polish market is not known, because relevant routinely studies have not been performed. Only the antibacterial and / or antifungal activity of certain formulations is sometimes assessed, especially when the manufacturer suggests the standardized application of the products for surgical or hygienic procedures. The aim of this study was to determine the microbiological quality, especially microbiological purity and antimicrobial activity of the selected hands washing products, presents on the Polish market. The 12 selected commercial products, available on the market in Poland, dedicated for hands washing were included into study. Microbiological purity test was carried out in accordance with the Polish Pharmacopoeia (FP) monograph (FP monograph numbers correspond to numbers of the European Pharmacopoeia monograph- Ph. Eur.) No 2.6.12 "Microbiological examination of non-sterile products: microbial enumaration tests", and the monograph of FP No. 2.6.13 "Microbiological examination of non-sterile products: test for specified microorganisms". The following physico-chemical properties of soaps were examined: the pH of the formulations was measured according to the monograph FP No. 2.2.3. "Potentiometric determination of pH", the density of products was assayed according to the monograph FPNo. 2.2.5. "Relative density" and determination the water activity was performed by monograph FP No 2.9.39 "Water-solid interactions: determination of sorption-desorption isotherms and of water activity". Next, antibacterial and antifungal protection was determined in accordance with the monograph FP No 5.1.3. "Efficacy of antimicrobial preservation". The study of antimicrobial activity was carried out in accordance with PN-EN 1040 "Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of basic bactericidal activity of chemical disinfectants and antiseptics - Test method and requirements (phase 1)". Finally, using the "time-kill" method the survival of microorganisms after different contact times of the products with bacteria and fungi were determined. All the examined products showed a very high microbiological purity. None of the formulations was characterized by a high acidity or alkalinity. All the analyzed products were slightly thicker than water, but such density of the preparation does not seem to be important parameter in the growth of microorganisms. The results of water activity estimation - the parameter indicating the presence of free, not chemically bound water stimulating microbes growth - do not show that low water content in the preparation may inhibit bacteria and fungi growth. Taking into consideration the antimicrobial protection of the products demonstrated in the tests carried out in accordance within FP monograph No 5.1.3. and PN-EN 1040, and analysing curves indicating killing rate of bacteria and fungi obtained by "time-kill" method, the microorganisms contaminating the products generally should not multiply in their environment, and gradually they die - what can take many hours or even days. The cases of bacterial infections connected with the usage of non-medical liguid soaps, applied in the health care units and described in the literature, should be considered as related rather to contamination of plastic packaging and dosage system, then to contamination of preparation itself inside the package. It was proved, that in all tested products amount of contaminating microbes diminishes in time. The dynamics of this process depends on the microorganisms character - bacteria dies quicker then fungi. The special attention should be given to washing, cleaning and disinfection of preparation dispensing systems, to avoid microbial contamination of product doses applied directly on the hands. It should be emphasized that only formulations containing antimicrobial agents in an appropriate amount, eliminate microorganisms from the skin surface fast and effectively. In case of hygienic and surgical procedures following the standardized manner in order to obtain required reduction rate of microorganisms in a short time - only products complying with appropriate EN standards are suitable. For these puroposes, the popular "liquid soaps" should not be used.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
[email protected] . Pipeline operators with potentially affected pipe or anyone with questions specific to... affected pipe. Chemical contamination was considered a potential source for degradation, but after... investigation of this incident included checking for the possibility of nylon contamination in the pipe material...
USDA-ARS?s Scientific Manuscript database
Contaminated eggs produced by infected commercial laying flocks are often implicated as sources of human infections with Salmonella Enteritidis, but Salmonella serovars Heidelberg and Typhimurium have also been significantly associated with egg-transmitted illness. Contamination of the edible conten...
Paridaens, J
2006-02-01
A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.
Harvey, R.W.; Metge, D.W.; Kinner, N.; Mayberry, N.
1997-01-01
Buoyant densities were determined for groundwater bacteria and microflagellates (protozoa) from a sandy aquifer (Cape Cod, MA) using two methods: (1) density-gradient centrifugation (DGC) and (2) Stoke's law approximations using sedimentation rates observed during natural-gradient injection and recovery tests. The dwarf (average cell size, 0.3 ??m), unattached bacteria inhabiting a pristine zone just beneath the water table and a majority (~80%) of the morphologically diverse community of free- living bacteria inhabiting a 5-km-long plume of organically-contaminated groundwater had DGC-determined buoyant densities <1.019 g/cm3 before culturing. In the aquifer, sinking rates for the uncultured 2-??m size class of contaminant plume bacteria were comparable to that of the bromide tracer (1.9 x 10-3 M), also suggesting a low buoyant density. Culturing groundwater bacteria resulted in larger (0.8-1.3 ??m), less neutrally- buoyant (1.043-1.081 g/cm3) cells with potential sedimentation rates up to 64-fold higher than those predicted for the uncultured populations. Although sedimentation generally could be neglected in predicting subsurface transport for the community of free-living groundwater bacteria, it appeared to be important for the cultured isolates, at least until they readapt to aquifer conditions. Culturing-induced alterations in size of the contaminant-plume microflagellates (2-3 ??m) were ameliorated by using a lower nutrient, acidic (pH 5) porous growth medium. Buoyant densities of the cultured microflagellates were low, i.e., 1.024-1.034 g/cm3 (using the DGC assay) and 1.017-1.039 g/cm3 (estimated from in-situ sedimentation rates), suggesting good potential for subsurface transport under favorable conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-09-29
The 4-acre Cemetery Dump site is a former sand and gravel pit in Rose Township, Oakland County, Michigan. During the late 1960s or early 1970s, approximately 300 to 600 drums, containing paint sludges, solvents, PCBs, and oils, were illegally dumped and buried onsite. A 1985 Record of Decision (ROD) addressed the soil cleanup which included excavation and offsite disposal of visually-contaminated soil and drum fragments. Soil which was not visually contaminated was sampled and backfilled with clean soil into the excavated areas. Subsequent soil and ground water sampling indicated that zinc contaminants in the ground water exceed the Federal secondarymore » MCL, a nonenforceable standard based on taste and odor, not protection of health. Zinc contamination, however, is most likely a result of monitoring well construction materials. No other contaminants exceed Federal or State environmental standards.« less
NASA Astrophysics Data System (ADS)
Mizukami, Kohji; Satoh, Kohki; Kanayama, Hiroshi; Itoh, Hidenori; Tagashira, Hiroaki; Shimozuma, Mitsuo; Okamoto, Hiroyuki; Takasaki, Satoko; Kinoshita, Muneshige
The hydroponic culture solution contaminated by fungi is sterilised by a DC corona discharge, and the sterilisation characteristics are investigated in this work. A DC streamer corona discharge is generated at atmospheric pressure in air between needle clusters and a water bath containing contaminated solution by fungus such as Fusarium oxysporum f. sp. spinaciae or Fusarium sp.. It is found that the fungi are killed by the exposure of the corona discharge, and that the death rates of the fungi chiefly depend on the concentration of the hydroponic culture solutions. It is also found that the number densities of the fungi decrease exponentially with the energy expenditure of the corona discharge, and that damping coefficients of the fungi densities depend on the concentration of the hydroponic culture solutions. This suggests that the fungi are chiefly inactivated by electroporation.
29 CFR 1910.19 - Special provisions for air contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 5 2010-07-01 2010-07-01 false Special provisions for air contaminants. 1910.19 Section 1910.19 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... Standards § 1910.19 Special provisions for air contaminants. (a) Asbestos, tremolite, anthophyllite, and...
Brogan, William R; Relyea, Rick A
2013-03-01
In ecotoxicology, appreciation is growing for the influence that ecological interactions have on the toxicity of contaminants, such as insecticides, to sensitive species. Most previous studies, however, have focused on factors that exacerbate insecticide effects on species, while factors that may mitigate these effects have been relatively ignored. In aquatic habitats, a small number of studies have shown that submersed macrophytes can remove some insecticides from the water column via sorption. Although examining sorption dynamics is important for understanding the environmental fate of insecticides, whether and to what extent macrophytes actually mitigate insecticide effects on aquatic species remains unknown. In the present study, the authors examined how much and how quickly several realistic densities of the macrophyte Elodea canadensis decreased the toxicity of the insecticide malathion to Daphnia magna, a keystone aquatic herbivore. To do this, the authors quantified Daphnia survival in outdoor test systems (0.95 L) exposed to a factorial combination of five Elodea densities crossed with five malathion concentrations. The authors discovered that malathion's lethality to Daphnia decreased with increasing Elodea density. Furthermore, the rate at which Elodea reduced malathion's toxicity in the water column increased with macrophyte density. These results provide strong evidence that submersed macrophytes can mitigate the ecological impacts of a popular insecticide and further support that ecological interactions can strongly influence contaminant environmental effects. Copyright © 2013 SETAC.
Johnson, L E; Bishop, T F A; Birch, G F
2017-11-15
The human population is increasing globally and land use is changing to accommodate for this growth. Soils within urban areas require closer attention as the higher population density increases the chance of human exposure to urban contaminants. One such example of an urban area undergoing an increase in population density is Sydney, Australia. The city also possesses a notable history of intense industrial activity. By integrating multiple soil surveys and covariates into a linear mixed model, it was possible to determine the main drivers and map the distribution of lead and zinc concentrations within the Sydney estuary catchment. The main drivers as derived from the model included elevation, distance to main roads, main road type, soil landscape, population density (lead only) and land use (zinc only). Lead concentrations predicted using the model exceeded the established guideline value of 300mgkg -1 over a large portion of the study area with concentrations exceeding 1000mgkg -1 in the south of the catchment. Predicted zinc did not exceed the established guideline value of 7400mgkg -1 ; however concentrations were higher to the south and west of the study area. Unlike many other studies we considered the prediction uncertainty when assessing the contamination risk. Although the predictions indicate contamination over a large area, the broadness of the prediction intervals suggests that in many of these areas we cannot be sure that the site is contaminated. More samples are required to determine the contaminant distribution with greater precision, especially in residential areas where contamination was highest. Managing sources and addressing areas of elevated lead and zinc concentrations in urban areas has the potential to reduce the impact of past human activities and improve the urban environment of the future. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of the photophysical properties of zearalenone using density functional theory
USDA-ARS?s Scientific Manuscript database
The intrinsic photophysical properties of the resorcylic acid moiety of zearalenone offer a convenient label free method to determine zearalenone levels in contaminated agricultural products. Density functional theory and steady-state fluorescence methods were applied to investigate the role of stru...
NBO analysis and vibrational frequencies of tautomers of citrinin by density functional theory
USDA-ARS?s Scientific Manuscript database
Citrinin is a toxic polyketide contaminant of a number of agricultural commodities, notably Monascus-fermented red rice. Detailed structures and electronic properties of three tautomeric forms of citrinin were investigated using density functional theory calculations at various extended basis sets ...
Development of Mullite Substrates and Containers
NASA Technical Reports Server (NTRS)
Sibold, J. D.
1979-01-01
The mullite-molten silicon interaction was evaluated through fabrication of a series of bodies made with variations in density, alumina-silica ratio, and glass-crystalline ratio. The materials were tested in a sessile drop technique. None of the variations stood up to extended exposure to molten silicon sufficiently to be recommended as a container material. However, directional solidification experiments suggest that, under proper conditions, contamination of the silicon by mullite containers can be minimized. To improve an already good thermal expansion match between mullite and silicon, compositional variations were studied. Altering of the alumina-silica ratio was determined to give a continuously varying thermal expansion. A standard mullite composition was selected and substrates 40 x 4 x .040 inches were fabricated. Slotted substrates of various configurations and various compositions were also fabricated.
Wide-field SCUBA-2 observations of NGC 2264: submillimetre clumps and filaments
NASA Astrophysics Data System (ADS)
Buckle, J. V.; Richer, J. S.
2015-10-01
We present wide-field observations of the NGC 2264 molecular cloud in the dust continuum at 850 and 450 μm using SCUBA-2 on the James Clerk Maxwell Telescope. Using 12CO 3 → 2 molecular line data, we determine that emission from CO contaminates the 850 μm emission at levels ˜30 per cent in localized regions associated with high-velocity molecular outflows. Much higher contamination levels of 60 per cent are seen in shocked regions near the massive star S Mon. If not removed, the levels of CO contamination would contribute an extra 13 per cent to the dust mass in NGC 2264. We use the FELLWALKER routine to decompose the dust into clumpy structures, and a Hessian-based routine to decompose the dust into filamentary structures. The filaments can be described as a hub-filament structure, with lower column density filaments radiating from the NGC 2264 C protocluster hub. Above mean filament column densities of 2.4 × 1022 cm-2, star formation proceeds with the formation of two or more protostars. Below these column densities, filaments are starless, or contain only a single protostar.
Green turtle fibropapillomatosis: challenges to assessing the role of environmental cofactors.
Herbst, L H; Klein, P A
1995-01-01
Green turtle fibropapillomatosis (GTFP) is a growing threat to the survival of green turtle (Chelonia mydas) populations worldwide. Recent transmission studies point to an infectious etiology. Several field studies suggest that high GTFP prevalence is associated with marine habitats that have been impacted by agricultural, industrial, or urban development. Environmental contaminants could be involved in GTFP through several plausible mechanisms including cocarcinogenesis and contaminant-induced immune suppression. However, an association of contaminants with GTFP has not been established. A broader perspective is needed when studying infectious diseases such as GTFP in complex ecosystems. Alternative explanations for high GTFP prevalence in some near-shore habitats include the following: a) these habitats provide an optimum physical environment for survival and transmission of the infectious agent; b) these habitats attract a high density of susceptible turtles or harbor a higher density of potential vectors, facilitating transmission of the pathogen in a density-dependent fashion; and c) these habitats may contain other stressors that render turtles more susceptible to GTFP. Application of scientifically rigorous criteria in the epizootiology of GTFP in free-ranging populations remains a formidable challenge. Images Figure 1. PMID:7556020
Well-characterized and standardized methods are the foundation upon which monitoring of regulated and unregulated contaminants in drinking water are based. To obtain reliable, high quality data for trace analysis of contaminants, these methods must be rugged, selective and sensit...
Although monitoring for surface contamination in work with radioactive materials and dermal monitoring of pesticide exposure to agricultural workers have been standard practice for 50 years, regular surface sampling and dermal monitoring methods have only been applied to indust...
Crespin, M A; Gallego, M; Valcárcel, M; González, J L
2001-11-01
Two phenoxyacid herbicides (2,4-D and MCPA) and their six corresponding phenols were determined in soil by using gas chomatography with electron impact mass spectrometry (GC/MS) for confirmation/quantitation. An automatic extraction (leaching), preconcentration, and cleanup (sorption) module was developed to extract the eight compounds from soil. The average recovery of all species, spiked to soil at microg/kg-mg/kg levels, was 95% (average standard deviation +/- 5%). A plot of agricultural clayey soil (approximately 12 m2) was contaminated with both herbicides (approximately 96 g/m3, depth 10 cm, density 1.23 g/cm3) and irrigated with (17 mm) at variable time intervals. Both herbicides and their corresponding phenol compounds were monitored at different soil depths over a 50 day period. The degradation of both herbicides in the surface layer (t(1/2) approximately 5 days) is a result of photodecomposition and microbial action; in the deeper layers, the degradation products occur in lower proportions by effect of leaching and are also the result of microbial action. The six phenol metabolites are only detected in the surface layer as they form preferentially by photodecomposition. The main metabolites (viz. 2,4-DCP for 2,4-D and 4-C-2-MP for MCPA) are formed within 24 h after the soil is contaminated; their concentration peaks are at day 8 in the absence of irrigation.
Domestic wells have high probability of pumping septic tank leachate
NASA Astrophysics Data System (ADS)
Horn, J. E.; Harter, T.
2011-06-01
Onsite wastewater treatment systems such as septic systems are common in rural and semi-rural areas around the world; in the US, about 25-30 % of households are served by a septic system and a private drinking water well. Site-specific conditions and local groundwater flow are often ignored when installing septic systems and wells. Particularly in areas with small lots, thus a high septic system density, these typically shallow wells are prone to contamination by septic system leachate. Typically, mass balance approaches are used to determine a maximum septic system density that would prevent contamination of the aquifer. In this study, we estimate the probability of a well pumping partially septic system leachate. A detailed groundwater and transport model is used to calculate the capture zone of a typical drinking water well. A spatial probability analysis is performed to assess the probability that a capture zone overlaps with a septic system drainfield depending on aquifer properties, lot and drainfield size. We show that a high septic system density poses a high probability of pumping septic system leachate. The hydraulic conductivity of the aquifer has a strong influence on the intersection probability. We conclude that mass balances calculations applied on a regional scale underestimate the contamination risk of individual drinking water wells by septic systems. This is particularly relevant for contaminants released at high concentrations, for substances which experience limited attenuation, and those being harmful even in low concentrations.
Bartos, Timothy T.; Quinn, Thomas L.; Hallberg, Laura L.; Eddy-Miller, Cheryl A.
2008-01-01
The quality of shallow ground water underlying unsewered low-density development outside of Sheridan and Lander, Wyo., and Red Lodge, Mont., was evaluated. In 2001, 29 wells (10 each in Sheridan and Lander and 9 in Red Lodge) were installed at or near the water table and sampled for a wide variety of constituents to identify potential effects of human activities on shallow ground-water quality resulting from development on the land surface. All wells were completed in unconfined aquifers in unconsolidated deposits of Quaternary age with shallow water tables (less than 50 feet below land surface). Land use and land cover was mapped in detail within a 500-meter radius surrounding each well, and potential contaminant sources were inventoried within the radii to identify human activities that may affect shallow ground-water quality. This U.S. Geological Survey National Water-Quality Assessment ground-water study was conducted to examine the effects of unsewered low-density development that often surrounds cities and towns of many different sizes in the western United States?a type of development that often is informally referred to as ?exurban? or ?rural ranchette? development. This type of development has both urban and rural characteristics. Residents in these developments typically rely on a private ground-water well for domestic water supply and a private septic system for sanitary waste disposal. Although the quality of shallow ground water generally was suitable for domestic or other uses without treatment, some inorganic constituents were detected infrequently in ground water in the three study areas at concentrations larger than U.S. Environmental Protection Agency drinking-water standards or proposed standards. Natural factors such as geology, aquifer properties, and ground-water recharge rates likely influence most concentrations of these constituents. These inorganic constituents generally occur naturally in the study areas and were more likely to limit suitability of water for drinking or other intended uses rather than any constituents suspected of being introduced as a result of human activities. Effects of human activities associated with low-density development, such as septic systems; fertilizer and pesticide use on pastures, lawns and gardens; manure from horses, cattle, and pets; and increases in road construction and vehicular traffic, were minimal at the time of sampling (2001) but were apparent in the presence of a few types of constituents in shallow ground water. Concentrations of nitrate generally were less than a national background level (1.1 milligrams per liter) assumed to indicate effects from human activities. Total coliform bacteria were detected infrequently (in samples from three wells), and Escherichia coli were not detected in samples from a subset of wells. Trace concentrations of methylene blue active substances (ingredients in laundry detergents) were detected at concentrations slightly greater than laboratory reporting levels in samples from 11 wells, but it is unclear if the detections are indicative of natural sources or possible aquifer contamination from septic-tank effluent. Pesticides were detected in both the Sheridan and Lander, Wyo., study areas. Volatile organic compounds were detected very infrequently in all three study areas. Most pesticides and volatile organic compounds were found in water from a few wells in each study area, and commonly as mixtures. The primary exception to this generalization was the relatively widespread detection of the pesticide prometon at trace levels in the Sheridan and Lander study areas. Concentrations of pesticides and volatile organic compounds generally were small and always were smaller than applicable drinking-water standards. Detections of all constituents indicating possible human effects on shallow ground-water quality were consistent with overlying land use mapped during the study, and potential sources of contamination inventoried du
USDA-ARS?s Scientific Manuscript database
Contaminated eggs produced by infected commercial laying flocks are often implicated as sources of human infections with Salmonella Enteritidis, but Salmonella serovars Heidelberg and Typhimurium have also been associated with egg-transmitted illness. Contamination of the edible contents of eggs is ...
USDA-ARS?s Scientific Manuscript database
The frequency of human infections with Salmonella Enteritidis (SE) has been linked to contaminated eggs and thus to SE prevalence in commercial egg-laying flocks. Contamination of the edible contents of eggs is a consequence of SE colonization of reproductive tissues in systemically infected hens. T...
USDA-ARS?s Scientific Manuscript database
Epidemiologic analyses have linked the frequency of human infections with Salmonella enterica subspecies enterica serovar Enteritidis to the consumption of contaminated eggs and thus to the prevalence of this pathogen in commercial egg-laying flocks. Contamination of the edible contents of eggs by S...
Kitzmann, Jennifer P; Pepper, Andrew R; Lopez, Boris G; Pawlick, Rena; Kin, Tatsuya; O’Gorman, Doug; Mueller, Kathryn R; Gruessner, Angelika C; Avgoustiniatos, Efstathios S; Karatzas, Theodore; Szot, Greg L; Posselt, Andrew M; Stock, Peter G; Wilson, John R; Shapiro, AM; Papas, Klearchos K
2014-01-01
The shipment of human islets from processing centers to distant laboratories is beneficial for both research and clinical applications. The maintenance of islet viability and function in transit is critically important. Gas-permeable silicone rubber membrane (SRM) vessels reduce the risk of hypoxia-induced death or dysfunction during high-density islet culture or shipment. SRM vessels may offer additional advantages: they are cost-effective (fewer flasks, less labor needed), safer (lower contamination risk), and simpler (culture vessel can also be used for shipment). Human islets(IE) were isolated from two manufacturing centers and shipped in 10cm2 surface area SRM vessels in temperature and pressure controlled containers to a distant center following at least two days of culture (n = 6). Three conditions were examined: low density (LD), high density (HD), and a micro centrifuge tube negative control (NC). LD was designed to mimic the standard culture density for human islet preparations (200 IE/cm2), while HD was designed to have a 20-fold higher tissue density, which would enable the culture of an entire human isolation in 1–3 vessels. Upon receipt, islets were assessed for viability, measured by oxygen consumption rate normalized to DNA content (OCR/DNA), and quantity, measured by DNA, and, when possible, potency and function with dynamic glucose-stimulated insulin secretion (GSIS) measurements and transplants in immunodeficient B6 rag mice. Post-shipment OCR/DNA was not reduced in HD versus LD, and was substantially reduced in the NC condition. HD islets exhibited normal function post-shipment. Based on the data we conclude that entire islet isolations (up to 400,000 IE) may be shipped using a single, larger SRM vessel with no negative effect on viability and ex vivo and in vivo function. PMID:25131090
Kitzmann, J P; Pepper, A R; Gala-Lopez, B; Pawlick, R; Kin, T; O'Gorman, D; Mueller, K R; Gruessner, A C; Avgoustiniatos, E S; Karatzas, T; Szot, G L; Posselt, A M; Stock, P G; Wilson, J R; Shapiro, A M; Papas, K K
2014-01-01
The shipment of human islets (IE) from processing centers to distant laboratories is beneficial for both research and clinical applications. The maintenance of islet viability and function in transit is critically important. Gas-permeable silicone rubber membrane (SRM) vessels reduce the risk of hypoxia-induced death or dysfunction during high-density islet culture or shipment. SRM vessels may offer additional advantages: they are cost-effective (fewer flasks, less labor needed), safer (lower contamination risk), and simpler (culture vessel can also be used for shipment). IE were isolated from two manufacturing centers and shipped in 10-cm(2) surface area SRM vessels in temperature- and pressure-controlled containers to a distant center after at least 2 days of culture (n = 6). Three conditions were examined: low density (LD), high density (HD), and a microcentrifuge tube negative control (NC). LD was designed to mimic the standard culture density for IE preparations (200 IE/cm(2)), while HD was designed to have a 20-fold higher tissue density, which would enable the culture of an entire human isolation in 1-3 vessels. Upon receipt, islets were assessed for viability (measured by oxygen consumption rate normalized to DNA content [OCR/DNA)]), quantity (measured by DNA), and, when possible, potency and function (measured by dynamic glucose-stimulated insulin secretion measurements and transplants in immunodeficient B6 Rag(+/-) mice). Postshipment OCR/DNA was not reduced in HD vs LD and was substantially reduced in the NC condition. HD islets exhibited normal function postshipment. Based on the data, we conclude that entire islet isolations (up to 400,000 IE) may be shipped using a single, larger SRM vessel with no negative effect on viability and ex vivo and in vivo function. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Rochaddi, Baskoro; Adhi Suryono, Chrisna; Atmodjo, Warsito; Satriadi, Alfi
2018-02-01
The present study was conducted to assess the level of pesticide and heavy metal contamination in shallow aquifer of Semarang coastal areas. Results indicated that Heptachlor and Arsenic were detected in the water samples in the range 0.023-0.055 μg L-1 and 0,03-1,63 μg L-1, respectively. Compared to the standard limits of the organochlorine contents in the water sample by World Health Organization (WHO) limits and Indonesian Drinking and Domestic Water Quality Standard for Ground Water (IWQS), groundwater of Semarang Coastal Areas was contaminated with pesticide and heavy metal. This study has proven the presence of organochlorine and heavy metal contamination of some shallow aquifer supplies in the coastal areas of Semarang.
Yalamanchi, Pratyusha; Yu, Jason; Chandler, Laura; Mirza, Natasha
2018-01-01
Objectives Despite increasing interest in individual instrument storage, risk of bacterial cross-contamination of otorhinolaryngology clinic instruments has not been assessed. This study is the first to determine the clinical efficacy and cost-effectiveness of standard high-level disinfection and clinic instrument storage. Methods To assess for cross-contamination, surveillance cultures of otorhinolaryngology clinic instruments subject to standard high-level disinfection and storage were obtained at the start and end of the outpatient clinical workday. Rate of microorganism recovery was compared with cultures of instruments stored in individual peel packs and control cultures of contaminated instruments. Based on historical clinic data, the direct allocation method of cost accounting was used to determine aggregate raw material cost and additional labor hours required to process and restock peel-packed instruments. Results Among 150 cultures of standard high-level disinfected and co-located clinic instruments, 3 positive bacterial cultures occurred; 100% of control cultures were positive for bacterial species ( P < .001). There was no statistical difference between surveillance cultures obtained before and after the clinic day. While there was also no significant difference in rate of contamination between peel-packed and co-located instruments, peel packing all instruments requires 6250 additional labor hours, and conservative analyses place the cost of individual semicritical instrument storage at $97,852.50 per year. Discussion With in vitro inoculation of >200 otorhinolaryngology clinic instruments, this study demonstrates that standard high-level disinfection and storage are equally efficacious to more time-consuming and expensive individual instrument storage protocols, such as peel packing, with regard to bacterial contamination. Implications for Practice Standard high-level disinfection and storage are equally effective to labor-intensive and costly individual instrument storage protocols.
The PBT-Josephine Facility accepts only wastewater from the oil and gas industry. This report describes the concentrations of selected contaminants in the effluent water and compares the contaminant effluent concentrations to state and federal standards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Will, M.E.; Suter, G.W. II
1994-09-01
One of the initial stages in ecological risk assessment for hazardous waste sites is screening contaminants to determine which of them are worthy of further consideration as contaminants of potential concern. This process is termed contaminant screening. It is performed by comparing measured ambient concentrations of chemicals to benchmark concentrations. Currently, no standard benchmark concentrations exist for assessing contaminants in soil with respect to their toxicity to plants. This report presents a standard method for deriving benchmarks for this purpose (phytotoxicity benchmarks), a set of data concerning effects of chemicals in soil or soil solution on plants, and a setmore » of phytotoxicity benchmarks for 38 chemicals potentially associated with United States Department of Energy (DOE) sites. In addition, background information on the phytotoxicity and occurrence of the chemicals in soils is presented, and literature describing the experiments from which data were drawn for benchmark derivation is reviewed. Chemicals that are found in soil at concentrations exceeding both the phytotoxicity benchmark and the background concentration for the soil type should be considered contaminants of potential concern.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suter, G.W. II
1993-01-01
One of the initial stages in ecological risk assessment for hazardous waste sites is screening contaminants to determine which of them are worthy of further consideration as contaminants of potential concern. This process is termed contaminant screening. It is performed by comparing measured ambient concentrations of chemicals to benchmark concentrations. Currently, no standard benchmark concentrations exist for assessing contaminants in soil with respect to their toxicity to plants. This report presents a standard method for deriving benchmarks for this purpose (phytotoxicity benchmarks), a set of data concerning effects of chemicals in soil or soil solution on plants, and a setmore » of phytotoxicity benchmarks for 38 chemicals potentially associated with United States Department of Energy (DOE) sites. In addition, background information on the phytotoxicity and occurrence of the chemicals in soils is presented, and literature describing the experiments from which data were drawn for benchmark derivation is reviewed. Chemicals that are found in soil at concentrations exceeding both the phytotoxicity benchmark and the background concentration for the soil type should be considered contaminants of potential concern.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Will, M.E.; Suter, G.W. II
1994-09-01
One of the initial stages in ecological risk assessments for hazardous waste sites is the screening of contaminants to determine which of them are worthy of further consideration as {open_quotes}contaminants of potential concern.{close_quotes} This process is termed {open_quotes}contaminant screening.{close_quotes} It is performed by comparing measured ambient concentrations of chemicals to benchmark concentrations. Currently, no standard benchmark concentrations exist for assessing contaminants in soil with respect to their toxicity to soil- and litter-dwelling invertebrates, including earthworms, other micro- and macroinvertebrates, or heterotrophic bacteria and fungi. This report presents a standard method for deriving benchmarks for this purpose, sets of data concerningmore » effects of chemicals in soil on invertebrates and soil microbial processes, and benchmarks for chemicals potentially associated with United States Department of Energy sites. In addition, literature describing the experiments from which data were drawn for benchmark derivation. Chemicals that are found in soil at concentrations exceeding both the benchmarks and the background concentration for the soil type should be considered contaminants of potential concern.« less
Septic system density and infectious diarrhea in a defined population of children.
Borchardt, Mark A; Chyou, Po-Huang; DeVries, Edna O; Belongia, Edward A
2003-05-01
One-quarter of U.S. households use a septic system for wastewater disposal. In this study we investigated whether septic system density was associated with endemic diarrheal illness in children. Cases--children 1 to < 19 years old seeking medical care for acute diarrhea--and controls resided in the Marshfield Epidemiologic Study Area, a population-based cohort in central Wisconsin. Enrollment was from February 1997 through September 1998. Study participants completed a structured interview, and septic system density was determined from county sanitary permits. Household wells were sampled for bacterial pathogens and indicators of water sanitary quality. Risk factors were assessed for cases grouped by diarrhea etiology. In multivariate analyses, viral diarrhea was associated with the number of holding tank septic systems in the 640-acre section surrounding the case residence [adjusted odds ratio (AOR), 1.08; 95% confidence interval (CI), 1.02-1.15; p = 0.008], and bacterial diarrhea was associated with the number of holding tanks per 40-acre quarter-quarter section (AOR, 1.22; 95% CI, 1.02-1.46; p = 0.026). Diarrhea of unknown etiology was independently associated with drinking from a household well contaminated with fecal enterococci (AOR, 6.18; 95% CI, 1.22-31.46; p = 0.028). Septic system densities were associated with endemic diarrheal illness in central Wisconsin. The association should be investigated in other regions, and standards for septic systems should be evaluated to ensure that the public health is protected.
Septic system density and infectious diarrhea in a defined population of children.
Borchardt, Mark A; Chyou, Po-Huang; DeVries, Edna O; Belongia, Edward A
2003-01-01
One-quarter of U.S. households use a septic system for wastewater disposal. In this study we investigated whether septic system density was associated with endemic diarrheal illness in children. Cases--children 1 to < 19 years old seeking medical care for acute diarrhea--and controls resided in the Marshfield Epidemiologic Study Area, a population-based cohort in central Wisconsin. Enrollment was from February 1997 through September 1998. Study participants completed a structured interview, and septic system density was determined from county sanitary permits. Household wells were sampled for bacterial pathogens and indicators of water sanitary quality. Risk factors were assessed for cases grouped by diarrhea etiology. In multivariate analyses, viral diarrhea was associated with the number of holding tank septic systems in the 640-acre section surrounding the case residence [adjusted odds ratio (AOR), 1.08; 95% confidence interval (CI), 1.02-1.15; p = 0.008], and bacterial diarrhea was associated with the number of holding tanks per 40-acre quarter-quarter section (AOR, 1.22; 95% CI, 1.02-1.46; p = 0.026). Diarrhea of unknown etiology was independently associated with drinking from a household well contaminated with fecal enterococci (AOR, 6.18; 95% CI, 1.22-31.46; p = 0.028). Septic system densities were associated with endemic diarrheal illness in central Wisconsin. The association should be investigated in other regions, and standards for septic systems should be evaluated to ensure that the public health is protected. PMID:12727604
NASA Astrophysics Data System (ADS)
Msilimba, Golden; Wanda, Elijah M. M.
In Malawi, shallow wells constitute the most important water sources for domestic purposes. However, increasing human population coupled with poor sanitation and infrastructure is undermining the quality of shallow well water. An assessment of microbial and geochemical quality of shallow well water in high-density areas of Zolozolo, Ching’ambo and Chiputula in Mzuzu City, Northern Malawi, has been carried out. The study aimed at characterising domestic water sources, identifying possible sources of water contamination and determining levels of microbial and chemical contamination. Arc-view GIS was used to map the water sources. A questionnaire survey was carried out to elicit information on characteristics of drinking water sources. Water samples were collected from quasi-randomly selected shallow wells and analysed for microbial and chemical parameters using standard methods. HCA, performed using R-programme, was used to group sampled sites according to their bio-physicochemical characteristics. Compliance of the water with MBS/WHO water quality guidelines was determined. The WQI was computed to turn multifaceted data obtained from laboratory analyses into simple information that is comprehensible and useable by the public to assess overall quality of water at a specific water points. The GW-chart was used to show hydrogeochemical water types from each sampled site. Microbial analysis revealed that water from 96.3% of shallow wells recorded faecal coliforms ranging from 129 to 920 cfu per 100 ml which were significantly higher than the Malawi Standards and WHO thresholds. In general, shallow well water is of low mineralisation (EC range 80-500 μS cm-1), with hydrogeochemical facies dominated by Ca-HCO3, which evolves to Ca-Cl water type. The shallow well water registered a WQI range of 50.16-66.04%, with a medium WQ rating. This suggested that the water obtained from the shallow wells is unsuitable for direct human consumption. It was observed that 100% of the shallow wells were at risk of pollution from onsite sanitation because of their proximity to sanitary facilities. It was strongly recommended that onsite treatment interventions have to be mobilised and initiated to protect the households from further possible consequences of using the water.
Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿
Lemieux, P.; Sieber, R.; Osborne, A.; Woodard, A.
2006-01-01
The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 106 spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275°F and 75 min at 45 lb/in2 and 292°F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275°F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process. PMID:17012597
Destruction of spores on building decontamination residue in a commercial autoclave.
Lemieux, P; Sieber, R; Osborne, A; Woodard, A
2006-12-01
The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 10(6) spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275 degrees F and 75 min at 45 lb/in2 and 292 degrees F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275 degrees F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process.
Treatment of chromium contaminated soil using bioremediation
NASA Astrophysics Data System (ADS)
Purwanti, Ipung Fitri; Putri, Tesya Paramita; Kurniawan, Setyo Budi
2017-11-01
Chromium contamination in soil occurs due to the disposal of chromium industrial wastewater or sludge that excess the quality standard. Chromium concentration in soil is ranged between 1 to 300 mg/kg while the maximum health standard is 2.5 mg/kg. Bioremediation is one of technology that could be used for remediating heavy metal contamination in soil. Bacteria have an ability to remove heavy metal from soil. One bacteria species that capable to remove chromium from soil is Bacillus subtilis. The aim of this research was to know the chromium removal percentage in contaminated soil by Bacillus subtilis. Artificial chromium contaminated soil was used by mixing 425gram sand and chromium trichloride solution. Concentration of chromium added into the spiked soil were 50, 75, and 100 mg/L. During 14 days, pH, soil temperature and soil moisture were tested. Initial and final number of bacterial colony and chromium concentration analysed. The result showed that the highest percentage of chromium removal was 11% at a chromium concentration of 75 mg/L
Infiltration characteristics of non-aqueous phase liquids in undisturbed loessal soil cores.
Wang, Yunqiang; Shao, Ming'an
2009-01-01
The widespread contamination of soils and aquifers by non-aqueous phase liquids (NAPL), such as crude oil, poses serious environmental and health hazards globally. Understanding the infiltration characteristics of NAPL in soil is crucial in mitigating or remediating soil contamination. The infiltration characteristics of crude and diesel oils into undisturbed loessal soil cores, collected in polymethyl methacrylate cylindrical columns, were investigated under a constant fluid head (3 cm) of either crude oil or diesel oil. The infiltration rate of both crude and diesel oils decreased exponentially as wetting depth increased with time. Soil core size and bulk density both had significant effects on NAPL infiltration through the undisturbed soil cores; a smaller core size or a greater bulk density could reduce oil penetration to depth. Compacting soil in areas susceptible to oil spills may be an effective stratage to reduce contamination. The infiltration of NAPL into soil cores was spatially anisotropic and heterogeneous, thus recording the data at four points on the soil core is a good stratage to improve the accuracy of experimental results. Our results revealed that crude and diesel oils, rather than their components, have a practical value for remediation of contaminated loessal soils.
Use of low density polyethylene membranes for assessment of genotoxicity of PAHs in the Seine River.
Vincent-Hubert, Françoise; Uher, Emmanuelle; Di Giorgio, Carole; Michel, Cécile; De Meo, Michel; Gourlay-France, Catherine
2017-03-01
The genotoxicity of river water dissolved contaminants is usually estimated after grab sampling of river water. Water contamination can now be obtained with passive samplers that allow a time-integrated sampling of contaminants. Since it was verified that low density polyethylene membranes (LDPE) accumulate labile hydrophobic compounds, their use was proposed as a passive sampler. This study was designed to test the applicability of passive sampling for combined chemical and genotoxicity measurements. The LDPE extracts were tested with the umu test (TA1535/pSK1002 ± S9) and the Ames assay (TA98, TA100 and YG1041 ± S9). We describe here this new protocol and its application in two field studies on four sites of the Seine River. Field LDPE extracts were negative with the YG1041 and TA100 and weakly positive with the TA98 + S9 and Umu test. Concentrations of labile mutagenic PAHs were higher upstream of Paris than downstream of Paris. Improvement of the method is needed to determine the genotoxicity of low concentrations of labile dissolved organic contaminants.
Effect of tidal fluctuations on contaminant transfer to the ocean
Licata, I.L.; Langevin, C.D.; Dausman, A.M.
2007-01-01
Variable-density groundwater flow was simulated to examine the effects that tide has on the coastward migration of a contaminant through a freshwater/saltwater interface and toward a coastal ocean boundary. Simulated ocean tides did not significantly affect the total contaminant mass input to the ocean; however, the difference in tidal and non-tidal simulated concentrations could be as much as 15%. It may be possible to numerically approximate the tidal-driven hydraulic transients in transport models that do not explicitly include tides by locally increasing dispersivity. Copyright ?? 2007 IAHS Press.
Estimating dermal transfer from PCB-contaminated porous surfaces.
Slayton, T M; Valberg, P A; Wait, A D
1998-06-01
Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.
NASA Astrophysics Data System (ADS)
Okhotnikov, V. V.; Linnik, S. A.; Gaidaichuk, A. V.; Shashev, D. V.; Nazarova, G. Yu; Yurchenko, V. I.
2016-02-01
A new method of selective deposition of polycrystalline diamond has been developed and studied. The diamond coatings with a complex, predetermined geometry and resolution up to 5 μm were obtained. A high density of polycrystallites in the coating area was reached (up to 32·107 pcs/cm2). The uniformity of the film reached 100%, and the degree of the surface contamination by parasitic crystals did not exceed 2%. The technology was based on the application of the standard photolithography with an addition of nanodiamond suspension into the photoresist that provided the creation of the centers of further nucleation in the areas which require further overgrowth. The films were deposited onto monocrystalline silicon substrates using the method of “hot filaments” in the CVD reactor. The properties of the coating and the impact of the nanodiamond suspension concentration in the photoresist were also studied. The potential use of the given method includes a high resolution, technological efficiency, and low labor costs compared to the standard methods (laser treatment, chemical etching in aggressive environments,).
The density-salinity relation of standard seawater
NASA Astrophysics Data System (ADS)
Schmidt, Hannes; Seitz, Steffen; Hassel, Egon; Wolf, Henning
2018-01-01
The determination of salinity by means of electrical conductivity relies on stable salt proportions in the North Atlantic Ocean, because standard seawater, which is required for salinometer calibration, is produced from water of the North Atlantic. To verify the long-term stability of the standard seawater composition, it was proposed to perform measurements of the standard seawater density. Since the density is sensitive to all salt components, a density measurement can detect any change in the composition. A conversion of the density values to salinity can be performed by means of a density-salinity relation. To use such a relation with a target uncertainty in salinity comparable to that in salinity obtained from conductivity measurements, a density measurement with an uncertainty of 2 g m-3 is mandatory. We present a new density-salinity relation based on such accurate density measurements. The substitution measurement method used is described and density corrections for uniform isotopic and chemical compositions are reported. The comparison of densities calculated using the new relation with those calculated using the present reference equations of state TEOS-10 suggests that the density accuracy of TEOS-10 (as well as that of EOS-80) has been overestimated, as the accuracy of some of its underlying density measurements had been overestimated. The new density-salinity relation may be used to verify the stable composition of standard seawater by means of routine density measurements.
NASA Astrophysics Data System (ADS)
Pan, Wenyong; Innanen, Kristopher A.; Geng, Yu
2018-03-01
Seismic full-waveform inversion (FWI) methods hold strong potential to recover multiple subsurface elastic properties for hydrocarbon reservoir characterization. Simultaneously updating multiple physical parameters introduces the problem of interparameter tradeoff, arising from the covariance between different physical parameters, which increases nonlinearity and uncertainty of multiparameter FWI. The coupling effects of different physical parameters are significantly influenced by model parameterization and acquisition arrangement. An appropriate choice of model parameterization is critical to successful field data applications of multiparameter FWI. The objective of this paper is to examine the performance of various model parameterizations in isotropic-elastic FWI with walk-away vertical seismic profile (W-VSP) dataset for unconventional heavy oil reservoir characterization. Six model parameterizations are considered: velocity-density (α, β and ρ΄), modulus-density (κ, μ and ρ), Lamé-density (λ, μ΄ and ρ‴), impedance-density (IP, IS and ρ″), velocity-impedance-I (α΄, β΄ and I_P^'), and velocity-impedance-II (α″, β″ and I_S^'). We begin analyzing the interparameter tradeoff by making use of scattering radiation patterns, which is a common strategy for qualitative parameter resolution analysis. In this paper, we discuss the advantages and limitations of the scattering radiation patterns and recommend that interparameter tradeoffs be evaluated using interparameter contamination kernels, which provide quantitative, second-order measurements of the interparameter contaminations and can be constructed efficiently with an adjoint-state approach. Synthetic W-VSP isotropic-elastic FWI experiments in the time domain verify our conclusions about interparameter tradeoffs for various model parameterizations. Density profiles are most strongly influenced by the interparameter contaminations; depending on model parameterization, the inverted density profile can be over-estimated, under-estimated or spatially distorted. Among the six cases, only the velocity-density parameterization provides stable and informative density features not included in the starting model. Field data applications of multicomponent W-VSP isotropic-elastic FWI in the time domain were also carried out. The heavy oil reservoir target zone, characterized by low α-to-β ratios and low Poisson's ratios, can be identified clearly with the inverted isotropic-elastic parameters.
Pan, Wenyong; Innanen, Kristopher A.; Geng, Yu
2018-03-06
We report seismic full-waveform inversion (FWI) methods hold strong potential to recover multiple subsurface elastic properties for hydrocarbon reservoir characterization. Simultaneously updating multiple physical parameters introduces the problem of interparameter tradeoff, arising from the covariance between different physical parameters, which increases nonlinearity and uncertainty of multiparameter FWI. The coupling effects of different physical parameters are significantly influenced by model parameterization and acquisition arrangement. An appropriate choice of model parameterization is critical to successful field data applications of multiparameter FWI. The objective of this paper is to examine the performance of various model parameterizations in isotropic-elastic FWI with walk-away vertical seismicmore » profile (W-VSP) dataset for unconventional heavy oil reservoir characterization. Six model parameterizations are considered: velocity-density (α, β and ρ'), modulus-density (κ, μ and ρ), Lamé-density (λ, μ' and ρ'''), impedance-density (IP, IS and ρ''), velocity-impedance-I (α', β' and I' P), and velocity-impedance-II (α'', β'' and I'S). We begin analyzing the interparameter tradeoff by making use of scattering radiation patterns, which is a common strategy for qualitative parameter resolution analysis. In this paper, we discuss the advantages and limitations of the scattering radiation patterns and recommend that interparameter tradeoffs be evaluated using interparameter contamination kernels, which provide quantitative, second-order measurements of the interparameter contaminations and can be constructed efficiently with an adjoint-state approach. Synthetic W-VSP isotropic-elastic FWI experiments in the time domain verify our conclusions about interparameter tradeoffs for various model parameterizations. Density profiles are most strongly influenced by the interparameter contaminations; depending on model parameterization, the inverted density profile can be over-estimated, under-estimated or spatially distorted. Among the six cases, only the velocity-density parameterization provides stable and informative density features not included in the starting model. Field data applications of multicomponent W-VSP isotropic-elastic FWI in the time domain were also carried out. Finally, the heavy oil reservoir target zone, characterized by low α-to-β ratios and low Poisson’s ratios, can be identified clearly with the inverted isotropic-elastic parameters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Wenyong; Innanen, Kristopher A.; Geng, Yu
We report seismic full-waveform inversion (FWI) methods hold strong potential to recover multiple subsurface elastic properties for hydrocarbon reservoir characterization. Simultaneously updating multiple physical parameters introduces the problem of interparameter tradeoff, arising from the covariance between different physical parameters, which increases nonlinearity and uncertainty of multiparameter FWI. The coupling effects of different physical parameters are significantly influenced by model parameterization and acquisition arrangement. An appropriate choice of model parameterization is critical to successful field data applications of multiparameter FWI. The objective of this paper is to examine the performance of various model parameterizations in isotropic-elastic FWI with walk-away vertical seismicmore » profile (W-VSP) dataset for unconventional heavy oil reservoir characterization. Six model parameterizations are considered: velocity-density (α, β and ρ'), modulus-density (κ, μ and ρ), Lamé-density (λ, μ' and ρ'''), impedance-density (IP, IS and ρ''), velocity-impedance-I (α', β' and I' P), and velocity-impedance-II (α'', β'' and I'S). We begin analyzing the interparameter tradeoff by making use of scattering radiation patterns, which is a common strategy for qualitative parameter resolution analysis. In this paper, we discuss the advantages and limitations of the scattering radiation patterns and recommend that interparameter tradeoffs be evaluated using interparameter contamination kernels, which provide quantitative, second-order measurements of the interparameter contaminations and can be constructed efficiently with an adjoint-state approach. Synthetic W-VSP isotropic-elastic FWI experiments in the time domain verify our conclusions about interparameter tradeoffs for various model parameterizations. Density profiles are most strongly influenced by the interparameter contaminations; depending on model parameterization, the inverted density profile can be over-estimated, under-estimated or spatially distorted. Among the six cases, only the velocity-density parameterization provides stable and informative density features not included in the starting model. Field data applications of multicomponent W-VSP isotropic-elastic FWI in the time domain were also carried out. Finally, the heavy oil reservoir target zone, characterized by low α-to-β ratios and low Poisson’s ratios, can be identified clearly with the inverted isotropic-elastic parameters.« less
NASA Astrophysics Data System (ADS)
Pan, Wenyong; Innanen, Kristopher A.; Geng, Yu
2018-06-01
Seismic full-waveform inversion (FWI) methods hold strong potential to recover multiple subsurface elastic properties for hydrocarbon reservoir characterization. Simultaneously updating multiple physical parameters introduces the problem of interparameter trade-off, arising from the simultaneous variations of different physical parameters, which increase the nonlinearity and uncertainty of multiparameter FWI. The coupling effects of different physical parameters are significantly influenced by model parametrization and acquisition arrangement. An appropriate choice of model parametrization is important to successful field data applications of multiparameter FWI. The objective of this paper is to examine the performance of various model parametrizations in isotropic-elastic FWI with walk-away vertical seismic profile (W-VSP) data for unconventional heavy oil reservoir characterization. Six model parametrizations are considered: velocity-density (α, β and ρ΄), modulus-density (κ, μ and ρ), Lamé-density (λ, μ΄ and ρ‴), impedance-density (IP, IS and ρ″), velocity-impedance-I (α΄, β΄ and I_P^' }) and velocity-impedance-II (α″, β″ and I_S^' }). We begin analysing the interparameter trade-off by making use of scattering radiation patterns, which is a common strategy for qualitative parameter resolution analysis. We discuss the advantages and limitations of the scattering radiation patterns and recommend that interparameter trade-offs be evaluated using interparameter contamination kernels, which provide quantitative, second-order measurements of the interparameter contaminations and can be constructed efficiently with an adjoint-state approach. Synthetic W-VSP isotropic-elastic FWI experiments in the time domain verify our conclusions about interparameter trade-offs for various model parametrizations. Density profiles are most strongly influenced by the interparameter contaminations; depending on model parametrization, the inverted density profile can be overestimated, underestimated or spatially distorted. Among the six cases, only the velocity-density parametrization provides stable and informative density features not included in the starting model. Field data applications of multicomponent W-VSP isotropic-elastic FWI in the time domain were also carried out. The heavy oil reservoir target zone, characterized by low α-to-β ratios and low Poisson's ratios, can be identified clearly with the inverted isotropic-elastic parameters.
The term "contaminant of emerging concern" is being used within the Office of Water to replace "emerging contaminant", a term that has been used loosely since the mid-1990s by EPA and others to identify chemicals and other substances that have no regulatory standard, have been re...
Code of Federal Regulations, 2013 CFR
2013-07-01
... and some soils are contaminated by such hazardous wastes. These treatment standards are also found in § 268.40, and are described in detail in § 268.42, Table 1. These wastes, and soils contaminated with... waste or soil contaminated with a waste, that displays a hazardous characteristic of ignitability...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and some soils are contaminated by such hazardous wastes. These treatment standards are also found in § 268.40, and are described in detail in § 268.42, Table 1. These wastes, and soils contaminated with... waste or soil contaminated with a waste, that displays a hazardous characteristic of ignitability...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and some soils are contaminated by such hazardous wastes. These treatment standards are also found in § 268.40, and are described in detail in § 268.42, Table 1. These wastes, and soils contaminated with... waste or soil contaminated with a waste, that displays a hazardous characteristic of ignitability...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and some soils are contaminated by such hazardous wastes. These treatment standards are also found in § 268.40, and are described in detail in § 268.42, Table 1. These wastes, and soils contaminated with... waste or soil contaminated with a waste, that displays a hazardous characteristic of ignitability...
Code of Federal Regulations, 2012 CFR
2012-07-01
... and some soils are contaminated by such hazardous wastes. These treatment standards are also found in § 268.40, and are described in detail in § 268.42, Table 1. These wastes, and soils contaminated with... waste or soil contaminated with a waste, that displays a hazardous characteristic of ignitability...
Optimal segmentation and packaging process
Kostelnik, Kevin M.; Meservey, Richard H.; Landon, Mark D.
1999-01-01
A process for improving packaging efficiency uses three dimensional, computer simulated models with various optimization algorithms to determine the optimal segmentation process and packaging configurations based on constraints including container limitations. The present invention is applied to a process for decontaminating, decommissioning (D&D), and remediating a nuclear facility involving the segmentation and packaging of contaminated items in waste containers in order to minimize the number of cuts, maximize packaging density, and reduce worker radiation exposure. A three-dimensional, computer simulated, facility model of the contaminated items are created. The contaminated items are differentiated. The optimal location, orientation and sequence of the segmentation and packaging of the contaminated items is determined using the simulated model, the algorithms, and various constraints including container limitations. The cut locations and orientations are transposed to the simulated model. The contaminated items are actually segmented and packaged. The segmentation and packaging may be simulated beforehand. In addition, the contaminated items may be cataloged and recorded.
FOREWORD: Special issue on density
NASA Astrophysics Data System (ADS)
Fujii, Kenichi
2004-04-01
This special issue on density was undertaken to provide readers with an overview of the present state of the density standards for solids, liquids and gases, as well as the technologies developed for measuring density. This issue also includes topics on the refractive index of gases and on techniques used for calibrating hydrometers so that almost all areas concerned with density standards are covered in four review articles and seven original articles, most of which describe current research being conducted at national metrology institutes (NMIs). A review article was invited from the Ruhr-Universität Bochum to highlight research on the magnetic suspension densimeters. In metrology, the determinations of the volume of a weight and the density of air are of primary importance in establishing a mass standard because the effect of the buoyancy force of air acting on the weight must be known accurately to determine the mass of the weight. A density standard has therefore been developed at many NMIs with a close relation to the mass standard. Hydrostatic weighing is widely used to measure the volume of a solid. The most conventional hydrostatic weighing method uses water as a primary density standard for measuring the volume of a solid. A brief history of the determination of the density of water is therefore given in a review article, as well as a recommended value for the density of water with a specified isotopic abundance. The most modern technique for hydrostatic weighing uses a solid density standard instead of water. For this purpose, optical interferometers for measuring the diameters of silicon spheres have been developed to convert the length standard into the volume standard with a small uncertainty. A review article is therefore dedicated to describing the state-of-the-art optical interferometers developed for silicon spheres. Relative combined standard uncertainties of several parts in 108 have been achieved today for measuring the volume and density of silicon spheres. These technologies are currently being used not only for establishing a solid density standard, but also for determining the Avogadro constant by the x-ray crystal density method, where the density, molar mass and lattice constant of a silicon crystal are measured based on the definition of the SI units. Considering that much of the present research on the Avogadro constant has been undertaken to replace the present definition of the kilogram with a new definition based on a number of atoms, it is satisfying to note that the most accurate density standard may contribute to a new definition of the kilogram. Differential density measurements by hydrostatic weighing and by the pressure of flotation method developed for measuring the density differences between silicon crystals and solids are given in a review article and three original articles, where combined standard uncertainties of a few parts in 108 have been achieved in measuring relative density differences. These technologies are being used not only for the determination of the Avogadro constant, but also for evaluating defects in silicon crystals used in the semiconductor industry. Another important liquid used in the density standard is mercury because the pressured standard determined from mercury column barometers, the molar gas constant determined from an acoustic resonator, and the Josephson constant determined from a mercury voltmeter are all dependent on the density of mercury. A review article is therefore dedicated to an overview of the history, recommended value and recent progress in the measurement of the density of mercury. This special issue also features the technologies developed for measuring the thermodynamic properties of fluids. New instruments with a magnetic suspension balance have substantially improved the uncertainty in measuring the density of fluids at elevated pressures and temperatures. Two review articles and an original article are therefore dedicated to describing the history, principle and recent progress in magnetic suspension densimeters. When the diamagnetic properties of organic liquids are taken into account, an unprecedented uncertainty of a few parts in 106 can be achieved for density measurements at high pressures. The papers collected in this special issue reflect the general trends in research on density standards. I hope that this special issue will stimulate new directions of research in the density standard, and also help to create more accurate, reliable and convenient methods for many applications. Thanks are addressed to all the authors who have contributed to this special issue on density, to the referees who have given their time, and also to the former editor Professor Martin and the present editor Dr~Williams for their support and useful suggestions in collecting the articles.
Liang, Ching-Ping; Chien, Yi-Chi; Jang, Cheng-Shin; Chen, Ching-Fang; Chen, Jui-Sheng
2017-01-14
Chronic arsenic (As) exposure continues to be a public health problem of major concern worldwide, affecting hundreds of millions of people. A long-term groundwater quality survey has revealed that 20% of the groundwater in southern Taiwan's Pingtung Plain is clearly contaminated with a measured As concentration in excess of the maximum level of 10 µg/L recommended by the World Health Organization. The situation is further complicated by the fact that more than half of the inhabitants in this area continue to use groundwater for drinking. Efforts to assess the health risk associated with the ingestion of As from the contaminated drinking water are required in order to determine the priorities for health risk management. The conventional approach to conducting a human health risk assessment may be insufficient for this purpose, so this study adopts a geostatistical Kriging method to perform a spatial analysis of the health risk associated with ingesting As through drinking groundwater in the Pingtung Plain. The health risk is assessed based on the hazard quotient (HQ) and target cancer risk (TR) established by the U.S. Environmental Protection Agency. The results show that most areas where the HQ exceeds 1 are in the southwestern part of the study area. In addition, the high-population density townships of Daliao, Linyuan, Donggang, Linbian, Jiadong, and Fangliao presently have exceedingly high TR values that are two orders of magnitude higher than the acceptable standard. Thus, the use of groundwater for drinking in these townships should be strictly avoided. A map that delineates areas with high TR values and high population densities is provided. The findings broaden the scope of the spatial analysis of human health risk and provide a basis for improving the decision-making process.
Liang, Ching-Ping; Chien, Yi-Chi; Jang, Cheng-Shin; Chen, Ching-Fang; Chen, Jui-Sheng
2017-01-01
Chronic arsenic (As) exposure continues to be a public health problem of major concern worldwide, affecting hundreds of millions of people. A long-term groundwater quality survey has revealed that 20% of the groundwater in southern Taiwan’s Pingtung Plain is clearly contaminated with a measured As concentration in excess of the maximum level of 10 µg/L recommended by the World Health Organization. The situation is further complicated by the fact that more than half of the inhabitants in this area continue to use groundwater for drinking. Efforts to assess the health risk associated with the ingestion of As from the contaminated drinking water are required in order to determine the priorities for health risk management. The conventional approach to conducting a human health risk assessment may be insufficient for this purpose, so this study adopts a geostatistical Kriging method to perform a spatial analysis of the health risk associated with ingesting As through drinking groundwater in the Pingtung Plain. The health risk is assessed based on the hazard quotient (HQ) and target cancer risk (TR) established by the U.S. Environmental Protection Agency. The results show that most areas where the HQ exceeds 1 are in the southwestern part of the study area. In addition, the high-population density townships of Daliao, Linyuan, Donggang, Linbian, Jiadong, and Fangliao presently have exceedingly high TR values that are two orders of magnitude higher than the acceptable standard. Thus, the use of groundwater for drinking in these townships should be strictly avoided. A map that delineates areas with high TR values and high population densities is provided. The findings broaden the scope of the spatial analysis of human health risk and provide a basis for improving the decision-making process. PMID:28098817
Monte Carlo simulation for background study of geophysical inspection with cosmic-ray muons
NASA Astrophysics Data System (ADS)
Nishiyama, Ryuichi; Taketa, Akimichi; Miyamoto, Seigo; Kasahara, Katsuaki
2016-08-01
Several attempts have been made to obtain a radiographic image inside volcanoes using cosmic-ray muons (muography). Muography is expected to resolve highly heterogeneous density profiles near the surface of volcanoes. However, several prior works have failed to make clear observations due to contamination by background noise. The background contamination leads to an overestimation of the muon flux and consequently a significant underestimation of the density in the target mountains. To investigate the origin of the background noise, we performed a Monte Carlo simulation. The main components of the background noise in muography are found to be low-energy protons, electrons and muons in case of detectors without particle identification and with energy thresholds below 1 GeV. This result was confirmed by comparisons with actual observations of nuclear emulsions. This result will be useful for detector design in future works, and in addition some previous works of muography should be reviewed from the view point of background contamination.
ISTA 14-in-situ accumulation of PAHs in low-density polyethylene membranes in sediment.
Devault, Damien A; Combe, Matthieu; Gourlay-Francé, Catherine
2010-10-01
The use of passive samplers for the assessment of organic contaminants has been extended to solid matrixes for the past decade. Passive sampling is usually applied to sediment in laboratory experiments involving significant upheaval, whereas in-situ experiments remain rare. In this study, low-density polyethylene (LDPE) strips were deployed within the sediments of a small river contaminated with polycyclic aromatic hydrocarbons (PAHs). LDPE strips were deployed in the 3-cm depth sediment layer. Over a period of 36 days, LDPE strips were regularly retrieved and accumulated PAHs in LDPE were extracted and analyzed. Accumulations of hydrophobic contaminants in LDPE directly exposed in the sediment were observed. Accumulations in LDPE were observed for moderately hydrophobic PAHs with the highest concentrations in the sediment. Low accumulations were observed for more hydrophobic compounds, despite their presence in high concentrations in the sediment. This was explained by very low exchange rates and competitive interactions with particles in the sediment. © 2010 Wiley Periodicals, Inc. Environ Toxicol, 2010.
SUPERNOVAE AND THEIR EXPANDING BLAST WAVES DURING THE EARLY EVOLUTION OF GALACTIC GLOBULAR CLUSTERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tenorio-Tagle, Guillermo; Silich, Sergiy; Muñoz-Tuñón, Casiana
2015-11-20
Our arguments deal with the early evolution of Galactic globular clusters and show why only a few of the supernovae (SNe) products were retained within globular clusters and only in the most massive cases (M ≥ 10{sup 6} M{sub ⊙}), while less massive clusters were not contaminated at all by SNe. Here, we show that SN blast waves evolving in a steep density gradient undergo blowout and end up discharging their energy and metals into the medium surrounding the clusters. This inhibits the dispersal and the contamination of the gas left over from a first stellar generation. Only the ejecta from well-centeredmore » SNe that evolve into a high-density medium available for a second stellar generation (2SG) in the most massive clusters would be retained. These are likely to mix their products with the remaining gas, eventually leading in these cases to an Fe-contaminated 2SG.« less
Quantitative relations between soil heavy metal contamination and landscape pattern in Wuxi, China
NASA Astrophysics Data System (ADS)
Zhu, Ming; Pu, Lijie; Xu, Yan
2017-04-01
Land use practices changed landscape pattern and meanwhile, brought forth numerous environmental problems including heavy metal contamination in soil. In this study, we investigated the quantitative relations between soil heavy metal contamination and its surrounding landscape pattern based on topsoil samples and land use map of Wuxi in 2009. The results of vector fitting with Redundancy analysis in R package vegan showed that Percent Coverage of build-up area (PCB) within 2500 m, Perimeter-Area Fractal Dimension (PAFD) within 2500 m, Edge Density (ED) within 2500 m, Patch Density (PD) within 200 m, Percent Coverage of wetland (PCW) within 2000 m and Patch Cohesion (PC) within 200 m significantly affected the contents of heavy metal elements. The results of Stepwise regression suggested that increase of build-up area and fragmentation would increase Cu and Zn, while increase of wetland would decrease the contents of As and Cu. PAFD was negative with Cd, Hg, Pb and Zn.
Detecting long-duration cloud contamination in hyper-temporal NDVI imagery
NASA Astrophysics Data System (ADS)
Ali, Amjad; de Bie, C. A. J. M.; Skidmore, A. K.
2013-10-01
Cloud contamination impacts on the quality of hyper-temporal NDVI imagery and its subsequent interpretation. Short-duration cloud impacts are easily removed by using quality flags and an upper envelope filter, but long-duration cloud contamination of NDVI imagery remains. In this paper, an approach that goes beyond the use of quality flags and upper envelope filtering is tested to detect when and where long-duration clouds are responsible for unreliable NDVI readings, so that a user can flag those data as missing. The study is based on MODIS Terra and the combined Terra-Aqua 16-day NDVI product for the south of Ghana, where persistent cloud cover occurs throughout the year. The combined product could be assumed to have less cloud contamination, since it is based on two images per day. Short-duration cloud effects were removed from the two products through using the adaptive Savitzky-Golay filter. Then for each 'cleaned' product an unsupervised classified map was prepared using the ISODATA algorithm, and, by class, plots were prepared to depict changes over time of the means and the standard deviations in NDVI values. By comparing plots of similar classes, long-duration cloud contamination appeared to display a decline in mean NDVI below the lower limit 95% confidence interval with a coinciding increase in standard deviation above the upper limit 95% confidence interval. Regression analysis was carried out per NDVI class in two randomly selected groups in order to statistically test standard deviation values related to long-duration cloud contamination. A decline in seasonal NDVI values (growing season) were below the lower limit of 95% confidence interval as well as a concurrent increase in standard deviation values above the upper limit of the 95% confidence interval were noted in 34 NDVI classes. The regression analysis results showed that differences in NDVI class values between the Terra and the Terra-Aqua imagery were significantly correlated (p < 0.05) with the corresponding standard deviation values of the Terra imagery in case of all NDVI classes of two selected NDVI groups. The method successfully detects long-duration cloud contamination that results in unreliable NDVI values. The approach offers scientists interested in time series analysis a method of masking by area (class) the periods when pre-cleaned NDVI values remain affected by clouds. The approach requires no additional data for execution purposes but involves unsupervised classification of the imagery to carry out the evaluation of class-specific mean NDVI and standard deviation values over time.
Emergence flux declines disproportionately to larval density along a stream metals gradient
Schmidt, Travis S.; Kraus, Johanna M.; Walters, David M.; Wanty, Richard B.
2013-01-01
Effects of contaminants on adult aquatic insect emergence are less well understood than effects on insect larvae. We compared responses of larval density and adult emergence along a metal contamination gradient. Nonlinear threshold responses were generally observed for larvae and emergers. Larval densities decreased significantly at low metal concentrations but precipitously at concentrations of metal mixtures above aquatic life criteria (Cumulative Criterion Accumulation Ratio (CCAR) ≥ 1). In contrast, adult emergence declined precipitously at low metal concentrations (CCAR ≤ 1), followed by a modest decline above this threshold. Adult emergence was a more sensitive indicator of the effect of low metals concentrations on aquatic insect communities compared to larvae, presumably because emergence is limited by a combination of larval survival and other factors limiting successful emergence. Thus effects of exposure to larvae are not manifest until later in life (during metamorphosis and emergence). This loss in emergence reduces prey subsidies to riparian communities at concentrations considered safe for aquatic life. Our results also challenge the widely held assumption that adult emergence is a constant proportion of larval densities in all streams.
Data Tables - Environments and Contaminants - Drinking Water Contaminants
This document contains a table of the estimated percentage of children ages 0 to 17 years served by community water systems that did not meet all applicable health-based drinking water standards, 1993-2009.
Oscar, T P
2013-01-01
The current study was undertaken to acquire data on contamination of chicken parts with Salmonella at retail and to acquire data on cross-contamination of cooked chicken with Salmonella from raw chicken during meal preparation. Whole raw chickens (n = 31) were obtained from local retail stores and cut into two wings, two breasts without skin or bones, two thighs, and two drumsticks. Data for cross-contamination were obtained by cutting up a sterile, cooked chicken breast with the same board and knife used to cut up the raw chicken. The board, knife, and latex gloves used by the food handler were not rinsed or washed before cutting up the sterile, cooked chicken breast, thus providing a worst-case scenario for cross-contamination. Standard curves for the concentration of Salmonella bacteria in 400 ml of buffered peptone water after 6 h of incubation of chicken parts as a function of the initial log number of Salmonella bacteria inoculated onto chicken parts were developed and used to enumerate Salmonella bacteria. Standard curves were not affected by the type of chicken part but did differ (P < 0.05) among the five isolates of Salmonella examined. Consequently, Salmonella bacteria were enumerated on naturally contaminated chicken parts using a standard curve developed with the serotype of Salmonella that was isolated from the original sample. The prevalence of contamination was 3 % (4 of 132), whereas the incidence of cross-contamination was 1.8 % (1 of 57). The positive chicken parts were a thigh from chicken 4, which contained 3 CFU of Salmonella enterica serotype Kentucky, and both wings, one thigh, and one cooked breast portion from chicken 15, which all contained 1 CFU of serotype 8,20:-:z(6). These results indicated that the poultry industry is providing consumers in the studied area with chicken that has a low prevalence and low number of Salmonella bacteria at retail and that has a low incidence and low level of cross-contamination of cooked chicken with Salmonella from raw chicken during meal preparation under a worst-case scenario.
Ramzaev, Valery; Mishine, Arkady; Golikov, Vladislav; Brown, Justin Emrys; Strand, Per
2007-01-01
Vertical distributions of 137Cs have been determined in vegetation-soil cores obtained from 30 different locations around two underground nuclear explosion sites--"Crystal" (event year - 1974) and "Kraton-3" (event year - 1978) in the Republic of Sakha (Yakutia), Russia. In 2001-2002, background levels of 137Cs surface contamination densities on control forest plots varied from 0.73 to 0.97 kBq m(-2) with an average of 0.84+/-0.10 kBq m(-2) and a median of 0.82 kBq m(-2). 137Cs ground contamination densities at the "Crystal" site ranged from 1.3 to 64 kBq m(-2); the activity gradually decreased with distance from the borehole. For "Kraton-3", residual surface contamination density of radiocaesium varied drastically from 1.7 to 6900 kBq m(-2); maximal 137Cs depositions were found at a "decontaminated" plot. At all forest plots, radiocaesium activity decreased throughout the whole vertical soil profile. Vertical distributions of 137Cs in soil for the majority of the plots sampled (n=18) can be described using a simple exponential function. Despite the fact that more than 20 years have passed since the main fallout events, more than 80% of the total deposited activity was found in the first 5 cm of the vegetation-soil cores from most of the forested landscapes. The low annual temperatures, clay-rich soil type with neutral pH, and presence of thick lichen-moss carpet are the factors which may hinder 137Cs transport down the soil profile.
Nakajima, Norihito; Nakano, Takashi; Harada, Fumiue; Taniguchi, Hiromasa; Yokoyama, Isao; Hirose, Jun; Daikoku, Eriko; Sano, Kouichi
2004-05-01
Tap water is one of the causative factors of hospital infections. We examined the disinfective potential of electrolysis and mechanism of disinfection, and clarified the disinfective effect of electrolysis on tap water contaminated with bacteria, and discussed its clinical applications. Tap waters artificially contaminated with Pseudomonas aeruginosa, Escherichia coli, Legionella pneumophila, and Staphylococcus aureus could be sterilized by electrolysis at 20-30 mA for 5 min. A high-density suspension (10(6) CFU/ml) of a spore forming bacterium, Bacillus subtilis was not completely sterilized by electrolysis at 50 mA up to 30 min, but a low-density suspension (10(5) CFU/ml) was totally sterilized by electrolysis at 50 mA for 5 min. Electrolyzed P. aeruginosa changed morphologically, that is, there was bleb formation on the cell wall and irregular aggregation of cytoplasmic small granules. Moreover, cytoplasmic enzyme, nitrate reductase, was inactivated by the electrolysis. On the other hand, genomic DNA of the electrolyzed bacteria was not degenerated, therefore, their DNA polymerase activity was not completely inactivated. Consequently, the major agent in electrolysis for bactericidal action was considered to be free chlorine, and the possible bactericidal mechanism was by destruction of bacterial membranes, followed by the aggregation of peripheral cytoplasmic proteins. Electrolysis of tap water for both disinfecting contaminating bacteria and increasing the disinfectant capacity was considered effective with some limitations, particularly against high-density contamination by spore-forming bacteria. In clinical settings, electrolysis of tap water is considered effective to disinfect water for hand washing in operation theatres, and bathing water for immunocompromised hosts.
Type of closure prevents microbial contamination of cosmetics during consumer use.
Brannan, D K; Dille, J C
1990-01-01
The dispensing closure used for containers plays an important role in protecting cosmetics from in-use microbial contamination. This hypothesis was tested by aseptically packing unpreserved shampoo and skin lotion into containers with three different closure types which provided various degrees of protection against consumer and environmental microbial insults. Shampoo was packed in containers with slit-cap (n = 25), flip-cap (n = 25), or screw-cap (n = 28) closures. Skin lotion was packed in containers with pump-top (n = 21), flip-cap (n = 18), or screw-cap (n = 21) closures. The products were then used by volunteers under actual in-use conditions for 3 (shampoo) or 2 (skin lotion) weeks. After use, the products were evaluated for microbial contamination by using standard methods for enumeration and identification. The standard screw-cap closure provided only minimal protection against microbial contamination of both the shampoo (29% contamination incidence) and the skin lotion (71%). The slit-cap closure on the shampoo container and the flip-cap closure on the skin lotion container provided slightly enhanced degrees of protection (21 and 39% contamination incidence, respectively). The greatest amount of protection (i.e., lowest contamination incidence) was provided by the flip-cap closure for the shampoo container (0%) and the pump-top closure for the skin lotion container (10%). As a result, closure type plays an important role in protecting poorly preserved products from in-use microbial contamination. Images PMID:2339896
Contamination of dried blood spots - an underestimated risk in newborn screening.
Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia
2018-01-26
Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.
Model Description for the SOCRATES Contamination Code
1988-10-21
Special A2-I V ILLUSTRATIONS A Schematic Representaction of the Major Elements or Shuttle Contaminacion Problem .... .............. 3 2 A Diagram of the...Atmospherically Scattered Molecules on Ambient Number Density for the 200, 250, and 300 Km Runs 98 A--I A Plot of the Chi-Square Probability Density Function...are scaled with respect to the far field ambient number density, nD, which leaves only the cross section scaling factor to be determined. This factor
Microplastic contamination of river beds significantly reduced by catchment-wide flooding
NASA Astrophysics Data System (ADS)
Hurley, Rachel; Woodward, Jamie; Rothwell, James J.
2018-04-01
Microplastic contamination of the oceans is one of the world's most pressing environmental concerns. The terrestrial component of the global microplastic budget is not well understood because sources, stores and fluxes are poorly quantified. We report catchment-wide patterns of microplastic contamination, classified by type, size and density, in channel bed sediments at 40 sites across urban, suburban and rural river catchments in northwest England. Microplastic contamination was pervasive on all river channel beds. We found multiple urban contamination hotspots with a maximum microplastic concentration of approximately 517,000 particles m-2. After a period of severe flooding in winter 2015/16, all sites were resampled. Microplastic concentrations had fallen at 28 sites and 18 saw a decrease of one order of magnitude. The flooding exported approximately 70% of the microplastic load stored on these river beds (equivalent to 0.85 ± 0.27 tonnes or 43 ± 14 billion particles) and eradicated microbead contamination at 7 sites. We conclude that microplastic contamination is efficiently flushed from river catchments during flooding.
[Establishment of Assessment Method for Air Bacteria and Fungi Contamination].
Zhang, Hua-ling; Yao, Da-jun; Zhang, Yu; Fang, Zi-liang
2016-03-15
In this paper, in order to settle existing problems in the assessment of air bacteria and fungi contamination, the indoor and outdoor air bacteria and fungi filed concentrations by impact method and settlement method in existing documents were collected and analyzed, then the goodness of chi square was used to test whether these concentration data obeyed normal distribution at the significant level of α = 0.05, and combined with the 3σ principle of normal distribution and the current assessment standards, the suggested concentrations ranges of air microbial concentrations were determined. The research results could provide a reference for developing air bacteria and fungi contamination assessment standards in the future.
Health-Based Screening Levels and their Application to Water-Quality Data
Toccalino, Patricia L.; Zogorski, John S.; Norman, Julia E.
2005-01-01
To supplement existing Federal drinking-water standards and guidelines, thereby providing a basis for a more comprehensive evaluation of contaminant-occurrence data in a human-health context, USGS began a collaborative project in 1998 with USEPA, the New Jersey Department of Environmental Protection, and the Oregon Health & Science University to calculate non-enforceable health-based screening levels. Screening levels were calculated for contaminants that do not have Maximum Contaminant Level values using a consensus approach that entailed (1) standard USEPA Office of Water methodologies (equations) for establishing Lifetime Health Advisory (LHA) and Risk-Specific Dose (RSD) values for the protection of human health, and (2) existing USEPA human-health toxicity information.
Florian, Maria; Yan, Jin; Ulhaq, Saad; Coughlan, Melanie; Laziyan, Mahemuti; Willmore, William; Jin, Xiaolei
2013-11-16
It has been reported that Northern populations are exposed to mixtures of various environmental contaminants unique to the Arctic (Northern contaminant mixtures - NCM) at a large range of concentrations, depending on their geological location, age, lifestyle and dietary habits. To determine if these contaminants may contribute to a cardiovascular health risk, especially when combined with a high fat and sugar diet and ethanol exposure, we treated human coronary artery endothelial cells (HCAEC) with two mixtures of 4 organic (NCM1) or 22 organic and inorganic (NCM2) chemicals detected in Northerners' blood during 2004-2005 in the presence or absence of low-density lipoprotein (1.5mg/ml), very-low-density lipoprotein (1.0mg/ml) and glucose (10mmol/L) (LVG), and in the absence or presence of 0.1% ethanol. After 24h of exposure, cell morphology and markers of cytotoxicity and endothelial function were examined. NCM1 treatment did not affect cell viability, but increased cell size, disrupted cell membrane integrity, and decreased cell density, uptake of small peptides, release of endothelin-1 (ET-1) and plasminogen activator inhibitor (PAI), while causing no changes in endothelial nitric oxide synthase (eNOS) protein expression and nitric oxide (NO) release. In contrast, NCM2 decreased cell viability, total protein yield, uptake of small peptides, eNOS protein expression, and NO release and caused membrane damage, but caused no changes in the secretion of ET-1, prostacyclin and PAI. The presence of LVG and/or alcohol did or did not influence the effects of NCM1 or NCM2 depending on the endpoint and the mixture examined. These results suggested that the effects of one or one group of contaminants may be altered by the presence of other contaminants, and that with or without the interaction of high fat and sugar diet and/or ethanol exposure, NCMs at the concentrations used caused endothelial dysfunction in vitro. It remains to be investigated if these effects of NCMs also occur in vivo. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas
2015-04-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.
Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas
2016-01-01
Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899
Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.
Gilmour, Stuart; Miyagawa, Shoji; Kasuga, Fumiko; Shibuya, Kenji
2016-01-01
The Great East Japan Earthquake on 11th March 2011 and the subsequent Fukushima Dai-ichi nuclear power plant disaster caused radioactive contamination in the surrounding environment. In the immediate aftermath of the accident the Government of Japan placed strict measures on radio-contamination of food, and enhanced radio-contamination monitoring activities. Japan is a pilot country in the WHO Foodborne Disease Burden Epidemiology Reference Group (FERG), and through this initiative has an opportunity to report on policy affecting chemicals and toxins in the food distribution network. Nuclear accidents are extremely rare, and a policy situation analysis of the Japanese government's response to the Fukushima Dai-ichi nuclear accident is a responsibility of Japanese scientists. This study aims to assess Japan government policies to reduce radio-contamination risk and to identify strategies to strengthen food policies to ensure the best possible response to possible future radiation accidents. We conducted a hand search of all publicly available policy documents issued by the Cabinet Office, the Food Safety Commission, the Ministry of Health, Labor and Welfare (MHLW), the Ministry of Agriculture, Forestry and Fishery (MAFF) and prefectural governments concerning food safety standards and changes to radiation and contamination standards since March 11th, 2011. We extracted information on food shipment and sales restrictions, allowable radio-contamination limits, monitoring activities and monitoring results. The standard for allowable radioactive cesium (Cs-134 and Cs-137) of 100 Bq/Kg in general food, 50 Bq/Kg in infant formula and all milk products, and 10 Bq/Kg in drinking water was enforced from April 2012 under the Food Sanitation Law, although a provisional standard on radio-contamination had been applied since the nuclear accident. Restrictions on the commercial sale and distribution of specific meat, vegetable and fish products were released for areas at risk of radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9%) were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9%) were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007-0.019 mSv/year), as did assessments of the contents of an average day's food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes. Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with producers and consumers should be more formalized to ensure their concerns are incorporated into regular policy reviews in an appropriate and transparent manner. However, despite the limited available knowledge on best practice in food control and enforcement of provisional radio-contamination limits after the accident, current Japanese policy is sufficient to protect the Japanese public from major risk of radio-contamination from the commercial food market.
Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis
Gilmour, Stuart; Miyagawa, Shoji; Kasuga, Fumiko; Shibuya, Kenji
2016-01-01
Background The Great East Japan Earthquake on 11th March 2011 and the subsequent Fukushima Dai-ichi nuclear power plant disaster caused radioactive contamination in the surrounding environment. In the immediate aftermath of the accident the Government of Japan placed strict measures on radio-contamination of food, and enhanced radio-contamination monitoring activities. Japan is a pilot country in the WHO Foodborne Disease Burden Epidemiology Reference Group (FERG), and through this initiative has an opportunity to report on policy affecting chemicals and toxins in the food distribution network. Nuclear accidents are extremely rare, and a policy situation analysis of the Japanese government’s response to the Fukushima Dai-ichi nuclear accident is a responsibility of Japanese scientists. This study aims to assess Japan government policies to reduce radio-contamination risk and to identify strategies to strengthen food policies to ensure the best possible response to possible future radiation accidents. Methods and Findings We conducted a hand search of all publicly available policy documents issued by the Cabinet Office, the Food Safety Commission, the Ministry of Health, Labor and Welfare (MHLW), the Ministry of Agriculture, Forestry and Fishery (MAFF) and prefectural governments concerning food safety standards and changes to radiation and contamination standards since March 11th, 2011. We extracted information on food shipment and sales restrictions, allowable radio-contamination limits, monitoring activities and monitoring results. The standard for allowable radioactive cesium (Cs-134 and Cs-137) of 100 Bq/Kg in general food, 50 Bq/Kg in infant formula and all milk products, and 10 Bq/Kg in drinking water was enforced from April 2012 under the Food Sanitation Law, although a provisional standard on radio-contamination had been applied since the nuclear accident. Restrictions on the commercial sale and distribution of specific meat, vegetable and fish products were released for areas at risk of radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9%) were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9%) were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007–0.019 mSv/year), as did assessments of the contents of an average day’s food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes. Conclusions Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with producers and consumers should be more formalized to ensure their concerns are incorporated into regular policy reviews in an appropriate and transparent manner. However, despite the limited available knowledge on best practice in food control and enforcement of provisional radio-contamination limits after the accident, current Japanese policy is sufficient to protect the Japanese public from major risk of radio-contamination from the commercial food market. PMID:27007509
Some Fundamental Issues in Ground-State Density Functional Theory: A Guide for the Perplexed.
Perdew, John P; Ruzsinszky, Adrienn; Constantin, Lucian A; Sun, Jianwei; Csonka, Gábor I
2009-04-14
Some fundamental issues in ground-state density functional theory are discussed without equations: (1) The standard Hohenberg-Kohn and Kohn-Sham theorems were proven for a Hamiltonian that is not quite exact for real atoms, molecules, and solids. (2) The density functional for the exchange-correlation energy, which must be approximated, arises from the tendency of electrons to avoid one another as they move through the electron density. (3) In the absence of a magnetic field, either spin densities or total electron density can be used, although the former choice is better for approximations. (4) "Spin contamination" of the determinant of Kohn-Sham orbitals for an open-shell system is not wrong but right. (5) Only to the extent that symmetries of the interacting wave function are reflected in the spin densities should those symmetries be respected by the Kohn-Sham noninteracting or determinantal wave function. Functionals below the highest level of approximations should however sometimes break even those symmetries, for good physical reasons. (6) Simple and commonly used semilocal (lower-level) approximations for the exchange-correlation energy as a functional of the density can be accurate for closed systems near equilibrium and yet fail for open systems of fluctuating electron number. (7) The exact Kohn-Sham noninteracting state need not be a single determinant, but common approximations can fail when it is not. (8) Over an open system of fluctuating electron number, connected to another such system by stretched bonds, semilocal approximations make the exchange-correlation energy and hole-density sum rule too negative. (9) The gap in the exact Kohn-Sham band structure of a crystal underestimates the real fundamental gap but may approximate the first exciton energy in the large-gap limit. (10) Density functional theory is not really a mean-field theory, although it looks like one. The exact functional includes strong correlation, and semilocal approximations often overestimate the strength of static correlation through their semilocal exchange contributions. (11) Only under rare conditions can excited states arise directly from a ground-state theory.
Statistical density modification using local pattern matching
Terwilliger, Thomas C.
2007-01-23
A computer implemented method modifies an experimental electron density map. A set of selected known experimental and model electron density maps is provided and standard templates of electron density are created from the selected experimental and model electron density maps by clustering and averaging values of electron density in a spherical region about each point in a grid that defines each selected known experimental and model electron density maps. Histograms are also created from the selected experimental and model electron density maps that relate the value of electron density at the center of each of the spherical regions to a correlation coefficient of a density surrounding each corresponding grid point in each one of the standard templates. The standard templates and the histograms are applied to grid points on the experimental electron density map to form new estimates of electron density at each grid point in the experimental electron density map.
Postmortem validation of breast density using dual-energy mammography
Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.
2014-01-01
Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548
Postmortem validation of breast density using dual-energy mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun
2014-08-15
Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less
2012-12-01
4.5 Food-grade aluminum foil 4.6 Stainless steel forceps 4.7 Single-edge razor blades 4.8 Teflon (or similar non-contaminating material) cutting...handling PE to avoid cross-contaminating the PE. 6.3 Methylene chloride (pesticide grade) rinsed, stainless steel forceps and scissors are used...3.1 PE is susceptible to contamination from atmospheric and surfaces, and so it must be handled using clean techniques. 3.2 While the formation of
Objectives and models of the planetary quarantine program
NASA Technical Reports Server (NTRS)
Werber, M.
1975-01-01
The objectives of the planetary quarantine program are presented and the history of early contamination prevention efforts is outlined. Contamination models which were previously established are given and include: determination of parameters; symbol nomenclature; and calculations of contamination and hazard probabilities. Planetary quarantine is discussed as an issue of national and international concern. Information on international treaty and meetings on spacecraft sterilization, quarantine standards, and policies is provided. The specific contamination probabilities of the U.S.S.R. Venus 3 flyby are included.
2013-09-01
ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON a. REPORT b. ABSTRACT c . THIS PAGE 19b. TELEPHONE NUMBER (include area code) Standard Form 298...Monitoring of Metals Concentration and Mobility in Contaminated Sediments N62583-11- C -0524 NAVFAC EXWC - Nancy Ruiz, Ph.D. Geosyntec Consultants...OF APPENDICES APPENDIX A: Representative Poor Electrochemical Scans APPENDIX B: Standard Solution Test Data APPENDIX C : Bremerton Porewater Test
2014-03-28
four sub-sections were included into “System” because none of them address limits of contaminates or chemicals in the water. 24 The Hazardous...maximum contaminant levels (MCL) of chemicals, stricter emission standards, stricter control limits, greater minimum separation distances, prohibited...0.37 Indonesia Strugglers 52.29 -0.40 Malaysia Progressives 62.51 0.34 Mongolia Regressives 45.37 -0.21 Myanmar Strugglers 52.72 -1.09 Nepal
Standards for contamination control
NASA Astrophysics Data System (ADS)
Borson, Eugene N.
2004-10-01
Standards are an important component of national and international trade. We depend upon standards to assure that manufactured parts will work together, wherever they are made, and that we speak the same technical language, no matter what language we speak. Understanding is important in order to know when to take exceptions to or tailor the standard to fit the job. Standards that are used in contamination control have increased in numbers over the years as more industries have had to improve their manufacturing processes to enhance reliability or yields of products. Some older standards have been revised to include new technologies, and many new standards have been developed. Some of the new standards were written for specific industries while others apply to many industries. Many government standards have been replaced with standards from nongovernmental standards organizations. This trend has been encouraged by U.S. law that requires the government to use commercial standards where possible. This paper reviews some of the more important standards for the aerospace industry, such as IEST-STD-CC1246 and ISO 14644-1, that have been published in recent years. Benefits, usage, and problems with some standards will be discussed. Some standards are referenced, and websites of some standards organizations are listed.
Ventilator-associated pneumonia risk decreased by use of oral moisture gel in oral health care.
Takeyasu, Yoshihiro; Yamane, Gen-Yuki; Tonogi, Morio; Watanabe, Yutaka; Nishikubo, Shuichi; Serita, Ryohei; Imura, Kumiko
2014-01-01
Although oral health care has a preventive effect against ventilator-associated pneumonia (VAP), the most effective method of oral health care in this respect remains to be established. The objective of this single-center, randomized, controlled trial was to investigate the relationship between VAP and various methods of oral health care. All patients included in the study (n=142) were on mechanical ventilation with oral intubation at the intensive care unit of the Tokyo Dental College Ichikawa General Hospital. They were divided into two groups, one receiving standard oral health care (Standard group), and the other receiving oral health care using an oral moisture gel instead of water (Gel group). After removal of the intubation tube, biofilm on cuff of the tube was stained with a disclosing agent to determine the contamination level. Factors investigated included sex, age, number of remaining teeth, intubation time, fever ≥38.5°C, VAP, cuff contamination level, and time required for one oral health care session. No VAP occurred in either group during the study period. The level of cuff contamination was significantly lower in the Gel group than the Standard group, and the time required for one session of oral health care was shorter (p<0.001). Multivariate analysis revealed use of the oral moisture gel as a factor affecting cuff contamination level. Use of an oral moisture gel decreased invasion of the pharynx by bacteria and contaminants together with biofilm formation on the intubation tube cuff. These results suggest that oral health care using an oral moisture gel is effective in preventing cuff contamination.
Ranjard, Lionel; Echairi, Abdelwahad; Nowak, Virginie; Lejon, David P H; Nouaïm, Rachida; Chaussod, Rémi
2006-11-01
The effects of Cu amendment on indigenous soil microorganisms were investigated in two soils, a calcareous silty clay (Ep) and a sandy soil (Au), by means of a 1-year field experiment and a two-month microcosm incubation. Cu was added as 'Bordeaux mixture' [CuSO(4), Ca(OH)(2)] at the standard rate used in viticulture (B1=16 kg Cu kg(-1) soil) and at a higher level of contamination (B3=48 kg Cu ha(-1) soil). More extractable Cu was observed in sandy soil (Au) than in silty soil (Ep). Furthermore, total Cu and Cu-EDTA declined with time in Au soil, whereas they remained stable in Ep soil. Quantitative modifications of the microflora were assessed by C-biomass measurements and qualitative modifications were assessed by the characterization of the genetic structure of bacterial and fungal communities from DNA directly extracted from the soil, using B- and F-ARISA (bacterial and fungal automated ribosomal intergenic spacer analysis). In the field study, no significant modifications were observed in C-biomass whereas microcosm incubation showed a decrease in B3 contamination only. ARISA fingerprinting showed slight but significant modifications of bacterial and fungal communities in field and microcosm incubation. These modifications were transient in all cases, suggesting a short-term effect of Cu stress. Microcosm experiments detected the microbial community modifications with greater precision in the short-term, while field experiments showed that the biological effects of Cu contamination may be overcome or hidden by pedo-climatic variations.
Surface Structure of TiO2 Rutile (011) Exposed to Liquid Water
2017-01-01
The rutile TiO2(011) surface exhibits a (2 × 1) reconstruction when prepared by standard techniques in ultrahigh vacuum (UHV). Here we report that a restructuring occurs upon exposing the surface to liquid water at room temperature. The experiment was performed in a dedicated UHV system, equipped for direct and clean transfer of samples between UHV and liquid environment. After exposure to liquid water, an overlayer with a (2 × 1) symmetry was observed containing two dissociated water molecules per unit cell. The two OH groups yield an apparent “c(2 × 1)” symmetry in scanning tunneling microscopy (STM) images. On the basis of STM analysis and density functional theory (DFT) calculations, this overlayer is attributed to dissociated water on top of the unreconstructed (1 × 1) surface. Investigation of possible adsorption structures and analysis of the domain boundaries in this structure provide strong evidence that the original (2 × 1) reconstruction is lifted. Unlike the (2 × 1) reconstruction, the (1 × 1) surface has an appropriate density and symmetry of adsorption sites. The possibility of contaminant-induced restructuring was excluded based on X-ray photoelectron spectroscopy (XPS) and low-energy He+ ion scattering (LEIS) measurements. PMID:29285204
Results from core-edge experiments in high Power, high performance plasmas on DIII-D
Petrie, T. W.; Fenstermacher, M. E.; Holcomb, C. T.; ...
2016-12-24
Here, significant challenges to reducing divertor heat flux in highly powered near-double null divertor (DND) hybrid plasmas, while still maintaining both high performance metrics and low enough density for application of RF heating, are identified. For these DNDs on DIII-D, the scaling of the peak heat flux at the outer target (q ⊥ P) ∝ [P SOL x I P] 0.92 for P SOL = 8-19 MW and I P = 1.0–1.4 MA, and is consistent with standard ITPA scaling for single-null H-mode plasmas. Two divertor heat flux reduction methods were tested. First, applying the puff-and-pump radiating divertor to DIII-Dmore » plasmas may be problematical at high power and H98 (≥ 1.5) due to improvement in confinement time with deuterium gas puffing which can lead to unacceptably high core density under certain conditions. Second, q ⊥ P for these high performance DNDs was reduced by ≈35% when an open divertor is closed on the common flux side of the outer divertor target (“semi-slot”) but also that heating near the slot opening is a significant source for impurity contamination of the core.« less
Propellant Improvement Program. Volume 2. Iron Contamination Effect in HDA (High Density Acid)
Density Acid ( HDA ) and the effect of iron impurity level up to 100 parts per million as Fe2O3 on HDA heat transfer. Thirty tests were conducted using...resistance heated, circular, 6061T6 aluminum tubes. Results showed that normal nucleate boiling did not occur with either of the HDA compositions. The
Sequestration Coating Performance Requirements for ...
symposium paper The EPA’s National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, developed performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... enclosure and shall be placed so as to minimize contamination. Food receptacles shall be kept clean and..., contamination, and deterioration or caking of food. ... Mammals Animal Health and Husbandry Standards § 3.129 Feeding. (a) The food shall be wholesome, palatable...
Improved simulation of aerosol, cloud, and density measurements by shuttle lidar
NASA Technical Reports Server (NTRS)
Russell, P. B.; Morley, B. M.; Livingston, J. M.; Grams, G. W.; Patterson, E. W.
1981-01-01
Data retrievals are simulated for a Nd:YAG lidar suitable for early flight on the space shuttle. Maximum assumed vertical and horizontal resolutions are 0.1 and 100 km, respectively, in the boundary layer, increasing to 2 and 2000 km in the mesosphere. Aerosol and cloud retrievals are simulated using 1.06 and 0.53 microns wavelengths independently. Error sources include signal measurement, conventional density information, atmospheric transmission, and lidar calibration. By day, tenuous clouds and Saharan and boundary layer aerosols are retrieved at both wavelengths. By night, these constituents are retrieved, plus upper tropospheric, stratospheric, and mesospheric aerosols and noctilucent clouds. Density, temperature, and improved aerosol and cloud retrievals are simulated by combining signals at 0.35, 1.06, and 0.53 microns. Particlate contamination limits the technique to the cloud free upper troposphere and above. Error bars automatically show effect of this contamination, as well as errors in absolute density nonmalization, reference temperature or pressure, and the sources listed above. For nonvolcanic conditions, relative density profiles have rms errors of 0.54 to 2% in the upper troposphere and stratosphere. Temperature profiles have rms errors of 1.2 to 2.5 K and can define the tropopause to 0.5 km and higher wave structures to 1 or 2 km.
NASA Astrophysics Data System (ADS)
Fujii, Hiroki; Iwanade, Akio; Kawada, Satoshi; Kitaguchi, Hitoshi
2018-01-01
The optimal heat treatment temperature (Topt) at which best performance in the critical current density (Jc) property at 4.2 K is obtained is influenced by the quality or reactivity of the filling powder in ex situ processed MgB2 tapes. Using a controlled fabrication process, the Topt decreases to 705-735 °C, which is lower than previously reported by more than 50 °C. The Topt decrease is effective to suppress both the decomposition of MgB2 and hence the formation of impurities such as MgB4, and the growth of crystallite size which decreases upper critical filed (Hc2). These bring about the Jc improvement and the Jc value at 4.2 K and 10 T reaches 250 A/mm2. The milling process also decreases the critical temperature (Tc) below 30 K. The milled powder is easily contaminated in air and thus, the Jc property of the contaminated tapes degrades severely. The contamination can raise the Topt by more than 50 °C, which is probably due to the increased sintering temperature required against contaminated surface layer around the grains acting as a barrier.
Kogbara, Reginald B
2017-01-28
Relationships among selected performance properties have been established using experimental data from a cement-stabilized mixed contaminated soil. The sandy soil was spiked with 3,000 mg/kg each of Cd, Cu, Pb, Ni and Zn, and 10,000 mg/kg of diesel. It was then treated with 5%, 10%, 15%, and 20% dosages of Portland cement. Different water contents were considered for lower dosage mixes. Selected geotechnical and leaching properties were determined on 28-day old samples. These include unconfined compressive strength (UCS), bulk density, porosity, hydraulic conductivity, leachate pH and granular leachability of contaminants. Interrelationships among these properties were deduced using the most reasonable best fits determined by specialized curve fitting software. Strong quadratic and log-linear relationships exist between hydraulic conductivity and UCS, with increasing binder and water contents, respectively. However, the strength of interrelationships between hydraulic conductivity and porosity, UCS and porosity, and UCS and bulk density varies with binder and water contents. Leachate pH and granular leachability of contaminants are best related to UCS and hydraulic conductivity by a power law and an exponential function, respectively. These results suggest how the accuracy of not-easily-measurable performance properties may be constrained from simpler ones. Comparisons with some published performance properties data support this.
Gustar, Nicole E.; Powell, Andrew L.; Hartnell, Rachel E.; Lees, David N.
2012-01-01
The contamination of bivalve shellfish with norovirus from human fecal sources is recognized as an important human health risk. Standardized quantitative methods for the detection of norovirus in molluscan shellfish are now available, and viral standards are being considered in the European Union and internationally. This 2-year systematic study aimed to investigate the impact of the application of these methods to the monitoring of norovirus contamination in oyster production areas in the United Kingdom. Twenty-four monthly samples of oysters from 39 United Kingdom production areas, chosen to represent a range of potential contamination risk, were tested for norovirus genogroups I and II by using a quantitative real-time reverse transcription (RT)-PCR method. Norovirus was detected in 76.2% (643/844) of samples, with all sites returning at least one positive result. Both prevalences (presence or absence) and norovirus levels varied markedly between sites. However, overall, a marked winter seasonality of contamination by both prevalence and quantity was observed. Correlations were found between norovirus contamination and potential risk indicators, including harvesting area classifications, Escherichia coli scores, and environmental temperatures. A predictive risk score for norovirus contamination was developed by using a combination of these factors. In summary, this study, the largest of its type undertaken to date, provides a systematic analysis of norovirus contamination in commercial oyster production areas in the United Kingdom. The data should assist risk managers to develop control strategies to reduce the risk of human illness resulting from norovirus contamination of bivalve molluscs. PMID:22685151
Kusuma, Aria; Eryando, Tris; Susanna, Dewi
2012-01-01
Contamination of baby's complementary food may occur with Escherichia coli from several sources including unclean utensils. We examined the relationship between socio-economic conditions, environmental factors, characteristics of food handlers and contamination of babies food-serving utensils with E. coli. The study was conducted in 21 villages of the Community Health Centre (CHC) Selayo in Indonesia. A cross-sectional design was used. A sample of 142 households, which had a 6-12 month-old baby on complementary food, was chosen randomly using midwives' registration books. Respondents were interviewed using a semi-structured questionnaire. Check-lists were used for observations. Standard laboratory methods were used for collection of specimen and confirmation of contamination with E. coli. More than half of the respondents (59.2%) used water that had high risk of contamination and 61.3% of the latrines did not meet the criteria of a healthy latrine. Waste management practices of nearly all respondents (97.9%) were below the standards set by the Ministry of Health. More than half of the respondents (68.3%) did not wash their hands with soap for 20 seconds and 52.1% did not use flowing water for washing hands. Majority of the respondents' hands (57%, 81/142) and 72.2% (104/142) of the eating utensils were found to be contaminated by E. coli. Contaminated hands of food handlers were more likely to contaminate the babies food-serving utensils (OR: 3.7; 95%CI: 1.62-8.46, p 0.002). Contamination of the hands of food handler was associated with contamination of babies food-serving utensils by E. coli. Hence, food handlers should be trained on proper hand washing methods.
40 CFR 265.112 - Closure plan; amendment of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination necessary to satisfy the closure performance standard; and (5) A detailed...
40 CFR 264.112 - Closure plan; amendment of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination required to satisfy the closure performance standard; and (5) A detailed...
Toxicology of the air in closed spaces
NASA Technical Reports Server (NTRS)
Wands, R. C.
1975-01-01
Sources and identification of contaminants in artificial gas atmospheres are discussed. They include biological sources (microflora and man), materials, processes, aerosols, and malfunctions. Acute or chronic toxicity may result from spacecraft air contamination. Air quality standards are presented in tabular form.
Mendoza, Rodolfo E; García, Ileana V; de Cabo, Laura; Weigandt, Cristian F; Fabrizio de Iorio, Alicia
2015-02-01
This study assessed the contamination by heavy metals (Cr, Cu, Pb, Zn), and nutrients (N, P) in soils and native plants, and the effect of the concentration of those elements with the density of arbuscular-mycorrhizal (AM) spores in soil and colonization in roots from the riverside of the Matanza-Riachuelo River Basin (MRRB). The concentration of metals and nutrients in soils and plants (Eleocharis montana, Cyperus eragrostis, Hydrocotyle bonariensis) increased from the upper sites (8 km from headwaters) to the lower sites (6 km from the mouth of the Riachuelo River) of the basin. AM-colonization on the roots of H. bonariensis and spore density in soil decreased as the concentrations of metals in soil and plant tissues increased from the upper to lower sites of the basin within a consistent gradient of contamination associated with land use, soil disturbance, population, and chemicals discharged into the streams and rivers along the MRRB. The general trends for all metals in plant tissue were to have highest concentrations in roots, then in rhizomes and lowest in aerial biomass. The translocation (TF) and bioconcentration (BCF) factors decreased in plants which grow from the upper sites to the lower sites of the basin. The plants tolerated a wide range in type and quantity of contamination along the basin by concentrating more metals and nutrients in roots than in aboveground tissue. The AM spore density in soil and colonization in roots of H. bonariensis decreased with the increase of the degree of contamination (Dc) in soil. Copyright © 2014 Elsevier B.V. All rights reserved.
Assessment of mercury in the Savannah River Site environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kvartek, E.J.; Carlton, W.H.; Denham, M.
Mercury has been valued by humans for several millennia. Its principal ore, cinnabar, was mined for its distinctive reddish-gold color and high density. Mercury and its salts were used as medicines and aphrodisiacs. At SRS, mercury originated from one of the following: as a processing aid in aluminum dissolution and chloride precipitation; as part of the tritium facilities` gas handling system; from experimental, laboratory, or process support facilities; and as a waste from site operations. Mercury is also found in Par Pond and some SRS streams as the result of discharges from a mercury-cell-type chlor-alkali plant near the city ofmore » Augusta, GA. Reactor cooling water, drawn from the Savannah River, transported mercury onto the SRS. Approximately 80,000 kg of mercury is contained in the high level waste tanks and 10,000 kg is located in the SWDF. Additional quantities are located in the various seepage basins. In 1992, 617 wells were monitored for mercury contamination, with 47 indicating contamination in excess of the 0.002-ppm EPA Primary Drinking Water Standard. More than 20 Savannah River Ecology Laboratory (SREL) reports and publications pertinent to mercury (Hg) have been generated during the last two decades. They are divided into three groupings: SRS-specific studies, basic studies of bioaccumulation, and basic studies of effect. Many studies have taken place at Par Pond and Upper Three Runs Creek. Mercury has been detected in wells monitoring the groundwater beneath SRS, but not in water supply wells in excess of the Primary Drinking Water Limit of 0.002 ppm. There has been no significant release of mercury from SRS to the Savannah River. While releases to air are likely, based on process knowledge, modeling of the releases indicates concentrations that are well below the SCDHEC ambient standard.« less
The effect of unresolved contaminant stars on the cross-matching of photometric catalogues
NASA Astrophysics Data System (ADS)
Wilson, Tom J.; Naylor, Tim
2017-07-01
A fundamental process in astrophysics is the matching of two photometric catalogues. It is crucial that the correct objects be paired, and that their photometry does not suffer from any spurious additional flux. We compare the positions of sources in Wide-field Infrared Survey Explorer (WISE), INT Photometric H α Survey, Two Micron All Sky Survey and AAVSO Photometric All Sky Survey with Gaia Data Release 1 astrometric positions. We find that the separations are described by a combination of a Gaussian distribution, wider than naively assumed based on their quoted uncertainties, and a large wing, which some authors ascribe to proper motions. We show that this is caused by flux contamination from blended stars not treated separately. We provide linear fits between the quoted Gaussian uncertainty and the core fit to the separation distributions. We show that at least one in three of the stars in the faint half of a given catalogue will suffer from flux contamination above the 1 per cent level when the density of catalogue objects per point spread function area is above approximately 0.005. This has important implications for the creation of composite catalogues. It is important for any closest neighbour matches as there will be a given fraction of matches that are flux contaminated, while some matches will be missed due to significant astrometric perturbation by faint contaminants. In the case of probability-based matching, this contamination affects the probability density function of matches as a function of distance. This effect results in up to 50 per cent fewer counterparts being returned as matches, assuming Gaussian astrometric uncertainties for WISE-Gaia matching in crowded Galactic plane regions, compared with a closest neighbour match.
The JCMT Gould Belt Survey: the effect of molecular contamination in SCUBA-2 observations of Orion A
NASA Astrophysics Data System (ADS)
Coudé, S.; Bastien, P.; Kirk, H.; Johnstone, D.; Drabek-Maunder, E.; Graves, S.; Hatchell, J.; Chapin, E. L.; Gibb, A. G.; Matthews, B.; JCMT Gould Belt Survey Team
2016-04-01
Thermal emission from cold dust grains in giant molecular clouds can be used to probe the physical properties, such as density, temperature and emissivity in star-forming regions. We present the Submillimetre Common-User Bolometer Array (SCUBA-2) shared-risk observations at 450 and 850 μm of the Orion A molecular cloud complex taken at the James Clerk Maxwell Telescope (JCMT). Previous studies showed that molecular emission lines can contribute significantly to the measured fluxes in those continuum bands. We use the Heterodyne Array Receiver Programme 12CO J = 3-2 integrated intensity map for Orion A in order to evaluate the molecular line contamination and its effects on the SCUBA-2 maps. With the corrected fluxes, we have obtained a new spectral index α map for the thermal emission of dust in the well-known integral-shaped filament. Furthermore, we compare a sample of 33 sources, selected over the Orion A molecular cloud complex for their high 12CO J = 3-2 line contamination, to 27 previously identified clumps in OMC 4. This allows us to quantify the effect of line contamination on the ratio of 850-450 μm flux densities and how it modifies the deduced spectral index of emissivity β for the dust grains. We also show that at least one Spitzer-identified protostellar core in OMC 5 has a 12CO J = 3-2 contamination level of 16 per cent. Furthermore, we find the strongest contamination level (44 per cent) towards a young star with disc near OMC 2. This work is part of the JCMT Gould Belt Legacy Survey.
Water quality and sources of fecal coliform bacteria in the Meduxnekeag River, Houlton, Maine
Culbertson, Charles W.; Huntington, Thomas G.; Stoeckel, Donald M.; Caldwell, James M.; O'Donnell, Cara
2014-01-01
In response to bacterial contamination in the Meduxnekeag River and the desire to manage the watershed to reduce contaminant sources, the Houlton Band of Maliseet Indians (HBMI) and the U.S. Geological Survey began a cooperative effort to establish a baseline of water-quality data that can be used in future studies and to indicate potential sources of nutrient and bacterial contamination. This study was conducted during the summer of 2005 in the Meduxnekeag River Basin near Houlton, Maine. Continuously recorded specific conductance can be a good indicator for water quality. Specific conductance increased downstream from the town of Houlton, between runoff events, and decreased sharply following major runoff events. Collections of discrete samples during the summer of 2005 indicated seasonal positive concentration-discharge relations for total phosphorus and total nitrogen; these results indicate that storm runoff may mobilize and transport these nutrients from the terrestrial environment to the river. Data collected by the HBMI on fecal coliform bacteria indicated that bacterial contamination enters the Meduxnekeag River from multiple paths including tributaries and surface drains (ditches) in developed areas in Houlton, Maine. The Houlton wastewater treatment discharge was not an important source of bacterial contamination. Bacteroidales-based tests for general fecal contamination (Bac32 marker) were predominantly positive in samples that had excessive fecal contamination as indicated by Enterococci density greater than 104 colony-forming units per 100 millilters. Of the 22 samples tested for Bacteroidales-based markers of human-associated fecal contamination (HF134 and HF183), 8 were positive. Of the 22 samples tested for Bacteroidales-based markers of ruminant-associated fecal contamination (CF128 and CF193), 7 were positive. Human fecal contamination was detected consistently at two sites (surface drains in urban areas in the town of Houlton) and occasionally detected at one site (Moose Brook) but was not detected at other sites. Fecal contamination (as indicated by fecal coliform density) apparently is localized under normal flow conditions with the highest levels restricted to drains in urban areas and to a lesser extent B Stream, Pearce Brook, and Big Brook, all tributaries to the main stem of the Meduxnekeag River. Coliphage were enumerated as an alternate indicator of fecal contamination with the intent of typing the virus into host-associated classes (human or ruminant), as was done for Enterococci; however, insufficient coliphage were isolated to provide more than preliminary indications. In spite of low coliphage enumeration, the preliminary results strengthen the conclusion that the Enterococci data correctly indicated the samples that contained human and ruminant fecal contamination. The finding that contamination was in many of the tributaries following storms in mid-July indicates that storm runoff likely carries fecal contaminants to more locations than runoff under lower flow conditions.
Optimal segmentation and packaging process
Kostelnik, K.M.; Meservey, R.H.; Landon, M.D.
1999-08-10
A process for improving packaging efficiency uses three dimensional, computer simulated models with various optimization algorithms to determine the optimal segmentation process and packaging configurations based on constraints including container limitations. The present invention is applied to a process for decontaminating, decommissioning (D and D), and remediating a nuclear facility involving the segmentation and packaging of contaminated items in waste containers in order to minimize the number of cuts, maximize packaging density, and reduce worker radiation exposure. A three-dimensional, computer simulated, facility model of the contaminated items are created. The contaminated items are differentiated. The optimal location, orientation and sequence of the segmentation and packaging of the contaminated items is determined using the simulated model, the algorithms, and various constraints including container limitations. The cut locations and orientations are transposed to the simulated model. The contaminated items are actually segmented and packaged. The segmentation and packaging may be simulated beforehand. In addition, the contaminated items may be cataloged and recorded. 3 figs.
Periodic processes in vapor phase biofiltration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moe, W.M.; Irvine, R.L.
1998-07-01
Most industrial processes and environmental remediation activities generate large volumes of air contaminated with low concentrations of volatile organic compounds. Carbon adsorption is the most widely used conventional treatment technology, but it has many drawbacks including secondary waste streams and excessive regeneration costs. Biofiltration, a microbial-based treatment technology, removes and biodegrades contaminants from a wide variety of waste streams without the disadvantages of carbon adsorption. In biofiltration, contaminated air flows through a packed bed containing microorganisms which convert contaminants primarily into carbon dioxide, water, and biomass. This paper describes how periodically operated, controlled unsteady state conditions were imposed on biofiltersmore » which used a new polyurethane foam medium that couples high porosity, suitable pore size, and low density with an ability to sorb water. The potential benefits associated with the controlled, unsteady-state operation of biofilters containing this new polyurethane foam medium are described herein. An example system treating a toluene contaminated waste gas is presented.« less
Saby, Marion; Larocque, Marie; Pinti, Daniele L; Barbecot, Florent; Gagné, Sylvain; Barnetche, Diogo; Cabana, Hubert
2017-02-01
There is growing concern worldwide about the exposure of groundwater resources to pharmaceutically active compounds (PhACs) and agricultural contaminants, such as pesticides, nitrate, and Escherichia coli. For regions with a low population density and an abundance of water, regional contamination assessments are not carried out systematically due to the typically low concentrations and high costs of analyses. The objectives of this study were to evaluate regional-scale contaminant distributions in untreated groundwater in a rural region of Quebec (Canada). The geological and hydrogeological settings of this region are typical of post-glacial regions around the world, where groundwater flow can be complex due to heterogeneous geological conditions. A new spatially distributed Anthropogenic Footprint Index (AFI), based on land use data, was developed to assess surface pollution risks. The Hydrogeochemical Vulnerability Index (HVI) was computed to estimate aquifer vulnerability. Nine wells had detectable concentrations of one to four of the 13 tested PhACs, with a maximum concentration of 116ng·L -1 for benzafibrate. A total of 34 of the 47 tested pesticides were detected in concentrations equal to or greater than the detection limit, with a maximum total pesticide concentration of 692ng·L -1 . Nitrate concentrations exceeded 1mg·L -1 N-NO 3 in 15.3% of the wells, and the Canadian drinking water standard was exceeded in one well. Overall, 13.5% of the samples had detectable E. coli. Including regional-scale sources of pollutants to the assessment of aquifer vulnerability with the AFI did not lead to the identification of contaminated wells, due to the short groundwater flow paths between recharge and the sampled wells. Given the occurrence of contaminants, the public health concerns stemming from these new data on regional-scale PhAC and pesticide concentrations, and the local flow conditions observed in post-glacial terrains, there is a clear need to investigate the sources and behaviours of local-scale pollutants. Copyright © 2016 Elsevier B.V. All rights reserved.
Contaminant Occurrence and Related Data for Six-Year Review of Drinking Water Standards
Learn about data EPA collects to conduct the Six-Year Review of National Primary Drinking Water Regulations. The data allows EPA to characterize frequency of occurrence, the levels found, and the geographic distribution of contaminants in drinking water.
Air Emission Regulations for the Prevention, Abatement and Control of Air Contaminents for areas involved in ambient air quality standards & regulations in MS + where to obtain copies of referenced federal regulations
METHODS FOR MONITORING PUMP-AND-TREAT PERFORMANCE
Since the 1980s, numerous pump-and-treat systems have been constructed to: (1) hydraulically contain contaminated ground water, and/or (2) restore ground-water quality to meet a desired standard such as background quality or Maximum Contaminant Level (MCL) concentrations for drin...
10 CFR 20.1406 - Minimization of contamination.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Minimization of contamination. 20.1406 Section 20.1406 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiological Criteria for... subsurface, in accordance with the existing radiation protection requirements in subpart B and radiological...
10 CFR 20.1406 - Minimization of contamination.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Minimization of contamination. 20.1406 Section 20.1406 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiological Criteria for... subsurface, in accordance with the existing radiation protection requirements in subpart B and radiological...
COLLECTION OF DESIGN DATA: SITE CHARACTERIZATION FOR PERMEABLE REACTIVE BARRIERS
Permeable reactive barriers (PRBs) for the restoration of contaminated ground water are no longer innovative. PRBs have evolved from innovative to accepted, standard practice, for the containment and treatment of a variety of contaminants in ground water. Like any remedial tech...
Metabolic measures of male southern toads (Bufo terrestris) exposed to coal combustion waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, C.K.; Appel, A.G.; Mendonca, M.T.
2006-03-15
Southern toads (Bufo terrestris) are found in coal fly ash collection basins associated with coal-burning electrical power plants. These basins contain large amounts of trace metals and organisms found in these basins are known to accumulate large quantities of metals. Studies on a variety of organisms exposed to trace metals found that they experience a significant increase in standard metabolic rate. We experimentally exposed southern toads to metal-contaminated sediment and food and measured changes in standard and exercise metabolic rates as well as changes in body, liver and muscle mass, blood glucose, and corticosterone. We found that toads exposed tomore » trace metal contamination gained significantly less mass (18.3%) than control toads (31.3%) when food was limited and experienced significantly decreased RQ after exercise. However, contaminated toads did not experience changes in standard or exercise metabolic rates, plasma glucose levels, and hepatic or muscle percentage indices whether food was limited or not.« less
A Permeable Active Amendment Concrete (PAAC) for Contaminant Remediation and Erosion Control
2012-06-01
124: 131 -143. SRNL-STI-2012-00356 70 Tessier, A., Campbell, P.G.C., and Bisson, M. 1979. Sequential extraction procedure for the speciation of...Bulk Density, Dry, (AI( C-D)]* p, pcf 134.85 Bulk Dens ity after Immersion, [BI(C-D)]* p, pcf 146.65 Bulk Density after Immersion & Boiling1 jCI (C
Estimating risks to aquatic life using quantile regression
Schmidt, Travis S.; Clements, William H.; Cade, Brian S.
2012-01-01
One of the primary goals of biological assessment is to assess whether contaminants or other stressors limit the ecological potential of running waters. It is important to interpret responses to contaminants relative to other environmental factors, but necessity or convenience limit quantification of all factors that influence ecological potential. In these situations, the concept of limiting factors is useful for data interpretation. We used quantile regression to measure risks to aquatic life exposed to metals by including all regression quantiles (τ = 0.05–0.95, by increments of 0.05), not just the upper limit of density (e.g., 90th quantile). We measured population densities (individuals/0.1 m2) of 2 mayflies (Rhithrogena spp., Drunella spp.) and a caddisfly (Arctopsyche grandis), aqueous metal mixtures (Cd, Cu, Zn), and other limiting factors (basin area, site elevation, discharge, temperature) at 125 streams in Colorado. We used a model selection procedure to test which factor was most limiting to density. Arctopsyche grandis was limited by other factors, whereas metals limited most quantiles of density for the 2 mayflies. Metals reduced mayfly densities most at sites where other factors were not limiting. Where other factors were limiting, low mayfly densities were observed despite metal concentrations. Metals affected mayfly densities most at quantiles above the mean and not just at the upper limit of density. Risk models developed from quantile regression showed that mayfly densities observed at background metal concentrations are improbable when metal mixtures are at US Environmental Protection Agency criterion continuous concentrations. We conclude that metals limit potential density, not realized average density. The most obvious effects on mayfly populations were at upper quantiles and not mean density. Therefore, we suggest that policy developed from mean-based measures of effects may not be as useful as policy based on the concept of limiting factors.
Boone, M.D.; Bridges, C.M.; Rothermel, B.B.
2001-01-01
Our objective was to determine how green frogs (Rana clamitans) are affected by multiple exposures to a sublethal level of the carbamate insecticide, carbaryl, in outdoor ponds. Tadpoles were added to 1,000-1 ponds at a low or high density which were exposed to carbaryl 0, 1, 2, or 3 times. Length of the larval period, mass, developmental stage, tadpole survival, and proportion metamorphosed were used to determine treatment effects. The frequency of dosing affected the proportion of green frogs that reached metamorphosis and the developmental stage of tadpoles. Generally, exposure to carbaryl increased rates of metamorphosis and development. The effect of the frequency of carbaryl exposure on development varied with the density treatment; the majority of metamorphs and the most developed tadpoles came from high-density ponds exposed to carbaryl 3 times. This interaction suggests that exposure to carbaryl later in the larval period stimulated metamorphosis, directly or indirectly, under high-density conditions. Our study indicates that exposure to a contaminant can lead to early initiation of metamorphosis and that natural biotic factors can mediate the effects of a contaminant in the environment.
Hartley, J; Cairney, J W; Freestone, P; Woods, C; Meharg, A A
1999-09-01
Experiments were conducted to investigate the effects of single and multiple metal contamination (Cd, Pb, Zn, Sb, Cu) on Scots pine seedlings colonised by ectomycorrhizal (ECM) fungi from natural soil inoculum. Seedlings were grown in either contaminated field soil from the site of a chemical accident, soils amended with five metals contaminating the site, or in soil from an uncontaminated control site. Although contaminated and metal-amended soil significantly inhibited root and shoot growth of the Scots pine seedlings, total root tip density was not affected. Of the five metals tested in amended soils, Cd was the most toxic to ECM Scots pine. Field-contaminated soil had a toxic effect on ECM fungi associated with Scots pine seedlings and caused shifts in ECM species composition on ECM seedlings. When compared to soils amended with only one metal, soils amended with a combination of all five metals tested had lower relative toxicity and less accumulation of Pb, Zn and Sb into seedlings. This would indicate that the toxicity of multiple metal contamination cannot be predicted from the individual toxicity of the metals investigated.
Thermochemical factors affecting the dehalogenation of aromatics.
Sadowsky, Daniel; McNeill, Kristopher; Cramer, Christopher J
2013-12-17
Halogenated aromatics are one of the largest chemical classes of environmental contaminants, and dehalogenation remains one of the most important processes by which these compounds are degraded and detoxified. The thermodynamic constraints of aromatic dehalogenation reactions are thus important for understanding the feasibility of such reactions and the redox conditions necessary for promoting them. Accordingly, the thermochemical properties of the (poly)fluoro-, (poly)chloro-, and (poly)bromobenzenes, including standard enthalpies of formation, bond dissociation enthalpies, free energies of reaction, and the redox potentials of Ar-X/Ar-H couples, were investigated using a validated density functional protocol combined with continuum solvation calculations when appropriate. The results highlight the fact that fluorinated aromatics stand distinct from their chloro- and bromo- counterparts in terms of both their relative thermodynamic stability toward dehalogenation and how different substitution patterns give rise to relevant properties, such as bond strengths and reduction potentials.
An unusual and persistent contamination of drinking water by cutting oil.
Rella, R; Sturaro, A; Parvoli, G; Ferrara, D; Doretti, L
2003-02-01
Drinking water contamination by materials, such as cutting oil, used to set up pipelines is an uncommon but possible event. This paper describes the analytical procedures used to identify the components of that contaminant in drinking water. Volatile and semi-volatile chemical species, responsible for an unpleasant taste and odour, were recognised by solid phase microextraction and GC/MS techniques. Among the volatile compounds, the presence of xylenes, bornyl acetate and diphenyl ether was confirmed by certificate standards and quantified in the most contaminated samples.
Ackerman, L.K.; Schwindt, A.R.; Simonich, S.L.M.; Koch, D.C.; Blett, T.F.; Schreck, C.B.; Kent, M.L.; Landers, D.H.
2008-01-01
Concentrations of polybrominated diphenyl ethers (PBDEs), pesticides, polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons were measured in 136 fish from 14 remote lakes in 8 western U.S. National Parks/Preserves between 2003 and 2005 and compared to human and wildlife contaminant health thresholds. A sensitive (median detection limit, -18 pg/g wet weight), efficient (61% recovery at 8 ng/g), reproducible (4.1% relative standard deviation (RSD)), and accurate (7% deviation from standard reference material (SRM)) analytical method was developed and validated for these analyses. Concentrations of PCBs, hexachlorobenzene, hexachlorocyclohexanes, DDTs, and chlordanes in western U.S. fish were comparable to or lower than mountain fish recently collected from Europe, Canada, and Asia. Dieldrin and PBDE concentrations were higher than recent measurements in mountain fish and Pacific Ocean salmon. Concentrations of most contaminants in western U.S. fish were 1-6 orders of magnitude below calculated recreational fishing contaminant health thresholds. However, lake average contaminant concentrations in fish exceeded subsistence fishing cancer thresholds in 8 of 14 lakes and wildlife contaminant health thresholds for piscivorous birds in 1of 14 lakes. These results indicate that atmospherically deposited organic contaminants can accumulate in high elevation fish, reaching concentrations relevant to human and wildlife health. ?? 2008 American Chemical Society.
Chong, Meng Nan; Sidhu, Jatinder; Aryal, Rupak; Tang, Janet; Gernjak, Wolfgang; Escher, Beate; Toze, Simon
2013-08-01
Stormwater is one of the last major untapped urban water resources that can be exploited as an alternative water source in Australia. The information in the current Australian Guidelines for Water Recycling relating to stormwater harvesting and reuse only emphasises on a limited number of stormwater quality parameters. In order to supply stormwater as a source for higher value end-uses, a more comprehensive assessment on the potential public health risks has to be undertaken. Owing to the stochastic variations in rainfall, catchment hydrology and also the types of non-point pollution sources that can provide contaminants relating to different anthropogenic activities and catchment land uses, the characterisation of public health risks in stormwater is complex, tedious and not always possible through the conventional detection and analytical methods. In this study, a holistic approach was undertaken to assess the potential public health risks in urban stormwater samples from a medium-density residential catchment. A combined chemical-toxicological assessment was used to characterise the potential health risks arising from chemical contaminants, while a combination of standard culture methods and quantitative polymerase chain reaction (qPCR) methods was used for detection and quantification of faecal indicator bacteria (FIB) and pathogens in urban stormwater. Results showed that the concentration of chemical contaminants and associated toxicity were relatively low when benchmarked against other alternative water sources such as recycled wastewater. However, the concentrations of heavy metals particularly cadmium and lead have exceeded the Australian guideline values, indicating potential public health risks. Also, high numbers of FIB were detected in urban stormwater samples obtained from wet weather events. In addition, qPCR detection of human-related pathogens suggested there are frequent sewage ingressions into the urban stormwater runoff during wet weather events. Further water quality monitoring study will be conducted at different contrasting urban catchments in order to undertake a more comprehensive public health risk assessment for urban stormwater.
1988 Hanford riverbank springs characterization report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dirkes, R.L.
1990-12-01
This reports presents the results of a special study undertaken to characterize the riverbank springs (i.e., ground-water seepage) entering the Columbia River along the Hanford Site. Radiological and nonradiological analyses were performed. River water samples were also analyzed from upstream and downstream of the Site as well as from the immediate vicinity of the springs. In addition, irrigation return water and spring water entering the river along the shoreline opposite Hanford were analyzed. Hanford-origin contaminants were detected in spring water entering the Columbia River along the Hanford Site. The type and concentrations of contaminants in the spring water were similarmore » to those known to exist in the ground water near the river. The location and extent of the contaminated discharges compared favorably with recent ground-water reports and predictions. Spring discharge volumes remain very small relative to the flow of the Columbia. Downstream river sampling demonstrates the impact of ground-water discharges to be minimal, and negligible in most cases. Radionuclide concentrations were below US Department of Energy Derived Concentration Guides (DCGs) with the exception {sup 90}Sr near the 100-N Area. Tritium, while below the DCG, was detected at concentrations above the US Environmental Protection Agency drinking water standards in several springs. All other radionuclide concentrations were below drinking water standards. Nonradiological contaminants were generally undetectable in the spring water. River water contaminant concentrations, outside of the immediate discharge zones, were below drinking water standards in all cases. 19 refs., 5 figs., 12 tabs.« less
Study on the influence of CR-39 detector size on radon progeny detection in indoor environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, L. A.; Hadler, J. C.; Lixandrão F, A. L.
It is well known that radon daughters up to {sup 214}Po are the real contaminants to be considered in case of indoor radon contamination. Assemblies consisting of 6 circular bare sheets of CR-39, a nuclear track detector, with radius varying from 0.15 to 1.2 cm were exposed far from any material surface for periods of approximately 6 months in 13 different indoor rooms (7 workplaces and 6 dwellings), where ventilation was moderate or poor. It was observed that track density was as greater as smaller was the detector radius. Track density data were fitted using an equation deduced based onmore » the assumption that the behavior of radon and its progeny in the air was described by Fick's Law, i.e., when the main mechanism of transport of radon progeny in the air is diffusion. As many people spend great part of their time in closed or poorly ventilated environments, the confirmation they present equilibrium between radon and its progeny is an interesting start for dosimetric calculations concerning this contamination.« less
Study on the influence of CR-39 detector size on radon progeny detection in indoor environments
NASA Astrophysics Data System (ADS)
Pereira, L. A.; Hadler, J. C.; Lixandrão F., A. L.; Guedes, S.; Takizawa, R. H.
2014-11-01
It is well known that radon daughters up to 214Po are the real contaminants to be considered in case of indoor radon contamination. Assemblies consisting of 6 circular bare sheets of CR-39, a nuclear track detector, with radius varying from 0.15 to 1.2 cm were exposed far from any material surface for periods of approximately 6 months in 13 different indoor rooms (7 workplaces and 6 dwellings), where ventilation was moderate or poor. It was observed that track density was as greater as smaller was the detector radius. Track density data were fitted using an equation deduced based on the assumption that the behavior of radon and its progeny in the air was described by Fick's Law, i.e., when the main mechanism of transport of radon progeny in the air is diffusion. As many people spend great part of their time in closed or poorly ventilated environments, the confirmation they present equilibrium between radon and its progeny is an interesting start for dosimetric calculations concerning this contamination.
In planta passive sampling devices for assessing subsurface chlorinated solvents.
Shetty, Mikhil K; Limmer, Matt A; Waltermire, Kendra; Morrison, Glenn C; Burken, Joel G
2014-06-01
Contaminant concentrations in trees have been used to delineate groundwater contaminant plumes (i.e., phytoscreening); however, variability in tree composition hinders accurate measurement of contaminant concentrations in planta, particularly for long-term monitoring. This study investigated in planta passive sampling devices (PSDs), termed solid phase samplers (SPSs) to be used as a surrogate tree core. Characteristics studied for five materials included material-air partitioning coefficients (Kma) for chlorinated solvents, sampler equilibration time and field suitability. The materials investigated were polydimethylsiloxane (PDMS), low-density polyethylene (LDPE), linear low-density polyethylene (LLDPE), polyoxymethylene (POM) and plasticized polyvinyl chloride (PVC). Both PDMS and LLDPE samplers demonstrated high partitioning coefficients and diffusivities and were further tested in greenhouse experiments and field trials. While most of the materials could be used for passive sampling, the PDMS SPSs performed best as an in planta sampler. Such a sampler was able to accurately measure trichloroethylene (TCE) and tetrachloroethylene (PCE) concentrations while simultaneously incorporating simple operation and minimal impact to the surrounding property and environment. Copyright © 2013 Elsevier Ltd. All rights reserved.
Estimating the number of terrestrial organisms on the moon.
NASA Technical Reports Server (NTRS)
Dillon, R. T.; Gavin, W. R.; Roark, A. L.; Trauth, C. A., Jr.
1973-01-01
Methods used to obtain estimates for the biological loadings on moon bound spacecraft prior to launch are reviewed, along with the mathematical models used to calculate the microorganism density on the lunar surface (such as it results from contamination deposited by manned and unmanned flights) and the probability of lunar soil sample contamination. Some of the results obtained by the use of a lunar inventory system based on these models are presented.
Vasudevan, Subramanyan; Lakshmi, Jothinathan; Jayaraj, Jeganathan; Sozhan, Ganapathy
2009-05-30
The present study provides an electrocoagulation process for the remediation of phosphate-contaminated water using aluminium, aluminium alloy and mild steel as the anodes and stainless steel as the cathode. The various parameters like effect of anode materials, effect of pH, concentration of phosphate, current density, temperature and co-existing ions, and so forth, and the adsorption capacity was evaluated using both Freundlich and Langmuir isotherm models. The adsorption of phosphate preferably fitting the Langmuir adsorption isotherm suggests monolayer coverage of adsorbed molecules. The results showed that the maximum removal efficiency of 99% was achieved with aluminium alloy anode at a current density of 0.2 A dm(-2), at a pH of 7.0. The adsorption process follows second-order kinetics.
How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.
Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay
2015-01-01
Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research.
He, Li; Xu, Zongda; Fan, Xing; Li, Jing; Lu, Hongwei
2017-05-01
This study develops a meta-modeling based mathematical programming approach with flexibility in environmental standards. It integrates numerical simulation, meta-modeling analysis, and fuzzy programming within a general framework. A set of models between remediation strategies and remediation performance can well guarantee the mitigation in computational efforts in the simulation and optimization process. In order to prevent the occurrence of over-optimistic and pessimistic optimization strategies, a high satisfaction level resulting from the implementation of a flexible standard can indicate the degree to which the environmental standard is satisfied. The proposed approach is applied to a naphthalene-contaminated site in China. Results show that a longer remediation period corresponds to a lower total pumping rate and a stringent risk standard implies a high total pumping rate. The wells located near or in the down-gradient direction to the contaminant sources have the most significant efficiency among all of remediation schemes.
30 CFR 71.702 - Asbestos standard.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Asbestos standard. 71.702 Section 71.702... Contaminants § 71.702 Asbestos standard. (a) Definitions. Asbestos is a generic term for a number of... fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophylite...
30 CFR 71.702 - Asbestos standard.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Asbestos standard. 71.702 Section 71.702... Contaminants § 71.702 Asbestos standard. (a) Definitions. Asbestos is a generic term for a number of... fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophylite...
30 CFR 71.702 - Asbestos standard.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Asbestos standard. 71.702 Section 71.702... Contaminants § 71.702 Asbestos standard. (a) Definitions. Asbestos is a generic term for a number of... fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophylite...
30 CFR 71.702 - Asbestos standard.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Asbestos standard. 71.702 Section 71.702... Contaminants § 71.702 Asbestos standard. (a) Definitions. Asbestos is a generic term for a number of... fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophylite...
30 CFR 71.702 - Asbestos standard.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Asbestos standard. 71.702 Section 71.702... Contaminants § 71.702 Asbestos standard. (a) Definitions. Asbestos is a generic term for a number of... fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophylite...
Code of Federal Regulations, 2010 CFR
2010-01-01
... minimize any risk of contamination by excreta and pests. Food receptacles must be kept clean and must be... molding, deterioration, contamination, or caking or wetting of food placed in self-feeders. ... nutritional standards. The food must be clean, wholesome, and palatable to the animals. It must be of...
10 CFR 20.1406 - Minimization of contamination.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Minimization of contamination. 20.1406 Section 20.1406 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Radiological Criteria for..., including the subsurface, in accordance with the existing radiation protection requirements in Subpart B and...
24 CFR 35.1345 - Occupant protection and worksite preparation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1345 Occupant... occupants and the environment from contamination from lead-contaminated or lead-containing materials during...
24 CFR 35.1345 - Occupant protection and worksite preparation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1345 Occupant... occupants and the environment from contamination from lead-contaminated or lead-containing materials during...
24 CFR 35.1345 - Occupant protection and worksite preparation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1345 Occupant... occupants and the environment from contamination from lead-contaminated or lead-containing materials during...
24 CFR 35.1345 - Occupant protection and worksite preparation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1345 Occupant... occupants and the environment from contamination from lead-contaminated or lead-containing materials during...
24 CFR 35.1345 - Occupant protection and worksite preparation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint Hazard Evaluation and Hazard Reduction Activities § 35.1345 Occupant... occupants and the environment from contamination from lead-contaminated or lead-containing materials during...
Health-risk based approach to setting drinking water standards for long-term space missions
NASA Technical Reports Server (NTRS)
Macler, Bruce A.; Dunsky, Elizabeth C.
1992-01-01
In order to develop plausible and appropriate drinking water contaminant standards for longer-term NASA space missions, such as those planned for the Space Exploration Initiative, a human health risk characterization was performed using toxicological and exposure values typical of space operations and crew. This risk characterization showed that the greatest acute waterborne health concern was from microbial infection leading to incapacitating gastrointestinal illness. Ingestion exposure pathways for toxic materials yielded de minimus acute health risks unlikely to affect SEI space missions. Risks of chronic health problems were within acceptable public health limits. Our analysis indicates that current Space Station Freedom maximum contamination levels may be unnecessarily strict. We propose alternative environmental contaminant values consistent with both acceptable short and long-term crew health safety.
Das, K; Biswas, S; Roughley, S; Bhojak, M; Niven, S
2014-03-01
To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time-density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having "good" arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kashiwagi, Toshiya; Suto, Yasushi; Taruya, Atsushi
The most widely used Galactic extinction map is constructed assuming that the observed far-infrared (FIR) fluxes come entirely from Galactic dust. According to the earlier suggestion by Yahata et al., we consider how FIR emission of galaxies affects the SFD map. We first compute the surface number density of Sloan Digital Sky Survey (SDSS) DR7 galaxies as a function of the r-band extinction, A {sub r,} {sub SFD}. We confirm that the surface densities of those galaxies positively correlate with A {sub r,} {sub SFD} for A {sub r,} {sub SFD} < 0.1, as first discovered by Yahata et al.more » for SDSS DR4 galaxies. Next we construct an analytical model to compute the surface density of galaxies, taking into account the contamination of their FIR emission. We adopt a log-normal probability distribution for the ratio of 100 μm and r-band luminosities of each galaxy, y ≡ (νL){sub 100} {sub μm}/(νL) {sub r}. Then we search for the mean and rms values of y that fit the observed anomaly, using the analytical model. The required values to reproduce the anomaly are roughly consistent with those measured from the stacking analysis of SDSS galaxies. Due to the limitation of our statistical modeling, we are not yet able to remove the FIR contamination of galaxies from the extinction map. Nevertheless, the agreement with the model prediction suggests that the FIR emission of galaxies is mainly responsible for the observed anomaly. Whereas the corresponding systematic error in the Galactic extinction map is 0.1-1 mmag, it is directly correlated with galaxy clustering and thus needs to be carefully examined in precision cosmology.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCray, J.E.; Boving, T.B.; Brusseau, M.L.
2000-12-31
Reagents that enhance the aqueous solubility of nonaqueous phase organic liquid (NAPL) contaminants are under investigation for use in enhanced subsurface remediation technologies. Cyclodextrin, a glucose-based molecule, is such a reagent. In this paper, laboratory experiments and numerical model simulations are used to evaluate and understand the potential remediation performance of cyclodextrin. Physical properties of cyclodextrin solutions such as density, viscosity, and NAPL-aqueous interfacial tension are measured. Their analysis indicates that no serious obstacles exist related to fluid properties that would prevent the use of cyclodextrin solutions for subsurface NAPL remediation. Cyclodextrin-enhanced solubilization for a large suite of typical groundmore » water contaminants is measured in the laboratory, and the results are related to the physiochemical properties of the organic compounds. The most-hydrophobic contaminants experience a larger relative solubility enhancement than the less-hydrophobic contaminants but have lower aqueous-phase apparent solubilities. Numerical model simulations of enhanced-solubilization flushing of NAPL-contaminated soil demonstrate that the more-hydrophilic compounds exhibit the greatest mass-removal relates due to their greater apparent solubilities, and thus are initially more effectively removed from soil by enhanced-solubilization-flushing reagents. However, the relatively more hydrophobic contaminants exhibit a greater improvement in contaminant mass-removal (compared with water flushing) than that exhibited for the relatively hydrophilic contaminants.« less
First Results from Contamination Monitoring with the WFC3 UVIS G280 Grism
NASA Astrophysics Data System (ADS)
Rothberg, B.; Pirzkal, N.; Baggett, S.
2011-11-01
The presence of contaminants within the optical light path of the instrument or telescope can alter photometric zeropoints and the observed flux levels of imaging and spectra, particularly at UV wavelengths. Regular monitoring of a spectro-photometric standard star using photometric filters has been used in the past to monitor the presence of contaminants and (when necessary) re-calibrate zeropoints. However, the use of the WFC3 UVIS Grism mode (G280 filter) may provide a more robust early alert detection system for the presence of contaminants, in particular, those that are photo-polymerized from the bright Earth. These contaminants may collect on surfaces in the optical light path of the telescope. The G280 grism is sensitive to light at wavelengths below the cutoff of the bluest UV filter (F218W). In this ISR, we present: 1) the first results from G280 monitoring for the period of 2010-November through 2011-August; 2) the discovery of an anomaly in the WCS header information of sub-array exposures; and 3) an outline for reducing standard G280 grism observations and the specialized case of observations obtained in sub-array mode.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and must be placed so as to minimize contamination of the food they contain. Such food receptacles... minimize contamination and that will assure that the food retains nutritive value and wholesome quality... Mammals Animal Health and Husbandry Standards § 3.105 Feeding. (a) The food for marine mammals must be...
29 CFR 1910.19 - Special provisions for air contaminants.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 5 2012-07-01 2012-07-01 false Special provisions for air contaminants. 1910.19 Section 1910.19 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Adoption and Extension of Established Federal...
29 CFR 1910.19 - Special provisions for air contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 5 2011-07-01 2011-07-01 false Special provisions for air contaminants. 1910.19 Section 1910.19 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Adoption and Extension of Established Federal...
Sediment toxicity tests are used for contaminated sediments, chemical registration, and water quality criteria evaluations and can be a core component of ecological risk assessments at contaminated sediments sites. Standard methods for conducting sediment toxicity tests have been...
Status of the waste assay for nonradioactive disposal (WAND) project
NASA Astrophysics Data System (ADS)
Arnone, Gaetano L.; Foster, Lynn A.; Foxx, Charles L.; Hagan, Roland C.; Martin, E. R.; Myers, Steven C.; Parker, Jack L.
1999-01-01
The WAND (Waste Assay for Nonradioactive Disposal) system scans thought-to-be-clean, low-density waste (mostly paper and plastics) to verify the absence of radioactive contaminants at very low-levels. Much of the low-density waste generated in radiologically controlled areas, formally considered `suspect' radioactive, is now disposed more cheaply at the Los Alamos County Landfill as opposed to the LANL Radioactive Waste Landfill.
Cleaning, disinfection and sterilization of surface prion contamination.
McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E
2013-12-01
Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
THREE-POINT PHASE CORRELATIONS: A NEW MEASURE OF NONLINEAR LARGE-SCALE STRUCTURE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolstenhulme, Richard; Bonvin, Camille; Obreschkow, Danail
2015-05-10
We derive an analytical expression for a novel large-scale structure observable: the line correlation function. The line correlation function, which is constructed from the three-point correlation function of the phase of the density field, is a robust statistical measure allowing the extraction of information in the nonlinear and non-Gaussian regime. We show that, in perturbation theory, the line correlation is sensitive to the coupling kernel F{sub 2}, which governs the nonlinear gravitational evolution of the density field. We compare our analytical expression with results from numerical simulations and find a 1σ agreement for separations r ≳ 30 h{sup −1} Mpc.more » Fitting formulae for the power spectrum and the nonlinear coupling kernel at small scales allow us to extend our prediction into the strongly nonlinear regime, where we find a 1σ agreement with the simulations for r ≳ 2 h{sup −1} Mpc. We discuss the advantages of the line correlation relative to standard statistical measures like the bispectrum. Unlike the latter, the line correlation is independent of the bias, in the regime where the bias is local and linear. Furthermore, the variance of the line correlation is independent of the Gaussian variance on the modulus of the density field. This suggests that the line correlation can probe more precisely the nonlinear regime of gravity, with less contamination from the power spectrum variance.« less
Rijgersberg, Hajo; Franz, Eelco; Nierop Groot, Masja; Tromp, Seth-Oscar
2013-07-01
Within a microbial risk assessment framework, modeling the maximum population density (MPD) of a pathogenic microorganism is important but often not considered. This paper describes a model predicting the MPD of Salmonella on alfalfa as a function of the initial contamination level, the total count of the indigenous microbial population, the maximum pathogen growth rate and the maximum population density of the indigenous microbial population. The model is parameterized by experimental data describing growth of Salmonella on sprouting alfalfa seeds at inoculum size, native microbial load and Pseudomonas fluorescens 2-79. The obtained model fits well to the experimental data, with standard errors less than ten percent of the fitted average values. The results show that the MPD of Salmonella is not only dictated by performance characteristics of Salmonella but depends on the characteristics of the indigenous microbial population like total number of cells and its growth rate. The model can improve the predictions of microbiological growth in quantitative microbial risk assessments. Using this model, the effects of preventive measures to reduce pathogenic load and a concurrent effect on the background population can be better evaluated. If competing microorganisms are more sensitive to a particular decontamination method, a pathogenic microorganism may grow faster and reach a higher level. More knowledge regarding the effect of the indigenous microbial population (size, diversity, composition) of food products on pathogen dynamics is needed in order to make adequate predictions of pathogen dynamics on various food products.
Understanding Land Use Impacts on Groundwater Quality Using Chemical Analysis
NASA Astrophysics Data System (ADS)
Nitka, A.; Masarik, K.; Masterpole, D.; Johnson, B.; Piette, S.
2017-12-01
Chippewa County, in western Wisconsin, has a unique historical set of groundwater quality data. The county conducted extensive groundwater sampling of private wells in 1985 (715 wells) and 2007 (800 wells). In 2016, they collaborated with UW-Extension and UW-Stevens Point to evaluate the current status of groundwater quality in Chippewa County by sampling of as many of the previously studied wells as possible. Nitrate was a primary focus of this groundwater quality inventory. Of the 744 samples collected, 60 were further analyzed for chemical indicators of agricultural and septic waste, two major sources of nitrate contamination. Wells for nitrate source analysis were selected from the 2016 participants based upon certain criteria. Only wells with a Wisconsin Unique Well Number were considered to ensure well construction information was available. Next, an Inverse Distance Weighting tool in ESRI ArcMap was used to assign values categorizing septic density. Two-thirds of the wells were selected in higher density areas and one-third in lower density areas. Equally prioritized was an even distribution of nitrate - N concentrations, with 28 of the wells having nitrate - N concentrations higher than the drinking water standard of 10 mg/L and 32 wells with concentrations between 2 and 10 mg/L. All wells with WUWN and nitrate - N concentrations greater than 20 mg/L were selected. The results of the nitrate source analyses will aid in determining temporal changes and spatial relationships of groundwater quality to soils, geology and land use in Chippewa County.
2014-04-01
added to a pre- weighed 125-ml low density polyethylene (LDPE) bottle. The particles were digested with 1.0 ml of concentrated trace metal grade (TMG...consideration to ensure completion of operations. 33 9. REFERENCES Breault, R. F., K. P. Smith, and J. R. Sorenson. 2005. “ Residential Street...of the Contaminants and Toxicity Associated with Particles in Stormwater Runoff.” Caltrans CTSW-RT-03-059.73.15. California Department of
Demonstration/Validation of a Surface Cleaning Control to Mitigate Storm Water Metal Contaminants
2014-04-01
added to a pre- weighed 125-ml low density polyethylene (LDPE) bottle. The particles were digested with 1.0 ml of concentrated trace metal grade (TMG...Sorenson. 2005. “ Residential Street-Dirt Accumulation Rates and Chemical Composition, and Removal Efficiencies by Mechanical- and Vacuum-Type...Bay, and M. Kayhanian. 2003. “A Review of the Contaminants and Toxicity Associated with Particles in Stormwater Runoff.” Caltrans CTSW-RT-03-059.73.15
9 CFR 113.32 - Detection of Brucella contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Brucella contamination. 113.32 Section 113.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... applicable Standard Requirement or in a filed Outline of Production for the product. (a) One ml of the minced...
NASA Technical Reports Server (NTRS)
Ledoux, F. N.
1970-01-01
The bibliography is arranged in separate sections under headings that include: (1) spacecraft cleanliness, (2) general cleaning, (3) clean room and work stations, (4) contamination, (5) decontamination, (6) manufacturing, (7) miscellaneous, (8) particle count analysis, (9) passivation, (10) packaging, (11) water, and (12) acids and detergents.
Partial Life-Cycle and Acute Toxicity of Perfluoroalkyl Acids to Freshwater Mussels
Freshwater mussels are among the most sensitive aquatic organisms to many contaminants and have complex life-cycles that include several distinct life stages with unique contaminant exposure pathways. Standard acute (24–96 h) and chronic (28 d) toxicity tests with free larva (glo...
Environmentally benign USPS stamps : baseline pilot recycling results
D. F. Seiter; M. A. Pikulin; R. G. Meese; Said M. Abubakr; David Bormett; Nancy Ross-Sutherland
1998-01-01
Stickies continue to represent the most challenging contaminant to remove from recycled secondary fiber. Current projections suggest that pressure sensitive adhesive (PSA) markets will continue to grow rapidly, increasing the concentration of these contaminants in common office-pack wastepaper. PSAas reformulated to exhibit higher removal efficiencies within standard...
Ground-Water Quality and its Relation to Land Use on Oahu, Hawaii, 2000-01
Hunt, Charles D.
2003-01-01
Water quality in the main drinking-water source aquifers of Oahu was assessed by a one-time sampling of untreated ground water from 30 public-supply wells and 15 monitoring wells. The 384 square-mile study area, which includes urban Honolulu and large tracts of forested, agricultural, and suburban residential lands in central Oahu, accounts for 93 percent of the island's ground-water withdrawals. Organic compounds were detected in 73 percent of public-supply wells, but mostly at low concentrations below minimum reporting levels. Concentrations exceeded drinking-water standards in just a few cases: the solvent trichloroethene and the radionuclide radon-222 exceeded Federal standards in one public-supply well each, and the fumigants 1,2-dibromo-3-chloropropane (DBCP) and 1,2,3-trichloropropane (TCP) exceeded State standards in three public-supply wells each. Solvents, fumigants, trihalomethanes, and herbicides were prevalent (detected in more than 30 percent of samples) but gasoline components and insecticides were detected in few wells. Most water samples contained complex mixtures of organic compounds: multiple solvents, fumigants, or herbicides, and in some cases compounds from two or all three of these classes. Characteristic suites of chemicals were associated with particular land uses and geographic locales. Solvents were associated with central Oahu urban-military lands whereas fumigants, herbicides, and fertilizer nutrients were associated with central Oahu agricultural lands. Somewhat unexpectedly, little contamination was detected in Honolulu where urban density is highest, most likely as a consequence of sound land-use planning, favorable aquifer structure, and less intensive application of chemicals (or of less mobile chemicals) over recharge zones in comparison to agricultural areas. For the most part, organic and nutrient contamination appear to reflect decades-old releases and former land use. Most ground-water ages were decades old, with recharge dates ranging from pre-1940 to the present, and with most dates falling within the 1950s to 1980s time span. Several widely detected compounds were discontinued as long ago as the 1970s but have yet to be flushed from the ground-water system. Although large tracts of land in central Oahu have been converted from agriculture to residential urban use since the 1950s, water quality in the converted areas still more closely reflects the former agricultural land. It appears to be too early to detect a distinct water-quality signature characteristic of the newer urban use, although several urban turfgrass herbicides in use for just 10 years or so were detected in monitoring wells and may represent early arrivals of urban contaminants at the water table.
Water as consumed and its impact on the consumer--do we understand the variables?
Bates, A J
2000-01-01
Water is the most important natural resource in the world, without it life cannot exist. In 1854 a cholera outbreak in London caused 10, 000 deaths and positively linked enteric disease with bacterial contamination of drinking water by sewage pollution. Since then, adequate water hygiene standards and sewage purification have played the most significant role in disease eradication and public health improvements everywhere. Standards for drinking water have become an extensive range of microbiological and chemical parametric values. Which has not increased consumer, if the media is to be believed. Customers rightly expect that the water they drink is safe and wholesome. Standard setting is perceived as a precise science and meaningful to health. Is this justified and do scientists and regulators who derive and set the standards understand the uncertainties in the system? Water is the universal solvent, therefore it will never be pure; it will contain impurities prior to and after treatment. Knowledge of its potential to become contaminated is necessary to understand the epidemiology associated with waterborne contaminants and their effects. Water use patterns vary considerably and affect assumptions based on toxicology derived from laboratory studies under tightly controlled conditions. Consideration must be given to the model systems used to assess toxicity and translate results from the laboratory to the real world, if sensible scientifically-based water quality standards are to be set and achieved cost effectively.
2008-03-01
foods such as fruits, vegetables, and beverages (U.S. FDA, 2004). If the U.S. EPA ultimately establishes a drinking water standard for perchlorate...TREAT PERCHLORATE-CONTAMINATED WATER THESIS Daniel A. Craig, Captain, USAF AFIT/GEM/ENV/08-M06 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY...OF AN INNOVATIVE TECHNOLOGY TO TREAT PERCHLORATE- CONTAMINATED WATER THESIS Presented to the Faculty Department of Systems and Engineering
Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.
Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup
2014-11-01
Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.
Silicon materials task of the low cost solar array project, phase 2
NASA Technical Reports Server (NTRS)
Hopkins, R. H.; Davis, J. R., Jr.; Blais, P. D.; Rohatgi, A.; Rai-Choudhury, P.; Hanes, M. H.; Mccormick, J. R.
1977-01-01
The object of phase 2 of this program is to investigate and define the effects of various processes, contaminants and process-contaminant interactions in the performance of terrestrial solar cells. The major effort this quarter was in the areas of crystal growth and thermal processing, comparison of impurity effects in low and high resistivity silicon, modeling the behavior of p-type ingots containing Mo, and C and, quantitative analysis of bulk lifetime and junction degradation effects in contaminated solar cells. The performance of solar cells fabricated on silicon web crystals grown from melts containing about 10 to the 18th power/cu cm of Cr, Mn, Fe, Ni, Ti, and V, respectively were measured. Deep level spectroscopy of metal-contaminated ingots was employed to determine the level and density of recombination centers due to Ti, V, Ni, and Cr.
Evaluation of a cleanser for petroleum-contaminated skin.
Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin
2003-12-01
Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.
Effect of beach management policies on recreational water quality.
Kelly, Elizabeth A; Feng, Zhixuan; Gidley, Maribeth L; Sinigalliano, Christopher D; Kumar, Naresh; Donahue, Allison G; Reniers, Adrianus J H M; Solo-Gabriele, Helena M
2018-04-15
When beach water monitoring programs identify poor water quality, the causes are frequently unknown. We hypothesize that management policies play an important role in the frequency of fecal indicator bacteria (FIB) exceedances (enterococci and fecal coliform) at recreational beaches. To test this hypothesis we implemented an innovative approach utilizing large amounts of monitoring data (n > 150,000 measurements per FIB) to determine associations between the frequency of contaminant exceedances and beach management practices. The large FIB database was augmented with results from a survey designed to assess management policies for 316 beaches throughout the state of Florida. The FIB and survey data were analyzed using t-tests, ANOVA, factor analysis, and linear regression. Results show that beach geomorphology (beach type) was highly associated with exceedance of regulatory standards. Low enterococci exceedances were associated with open coast beaches (n = 211) that have sparse human densities, no homeless populations, low densities of dogs and birds, bird management policies, low densities of seaweed, beach renourishment, charge access fees, employ lifeguards, without nearby marinas, and those that manage storm water. Factor analysis and a linear regression confirmed beach type as the predominant factor with secondary influences from grooming activities (including seaweed densities and beach renourishment) and beach access (including charging fees, employing lifeguards, and without nearby marinas). Our results were observable primarily because of the very large public FIB database available for analyses; similar approaches can be adopted at other beaches. The findings of this research have important policy implications because the selected beach management practices that were associated with low levels of FIB can be implemented in other parts of the US and around the world to improve recreational beach water quality. Copyright © 2018 Elsevier Ltd. All rights reserved.
Cadmium contamination in cereal-based diets and diet ingredients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siitonen, P.H.; Thompson, H.C. Jr.
1990-11-01
Cereal-based diet and/or diet ingredient cadmium levels were determined by graphite furnace AAS. Cadmium contamination was 88.3 and 447 ppb in two cereal-based diets, 44.6 and 48.9 ppb in two purified diets, and ranged from less than 1.1 to 22,900 ppb in the ingredients of one cereal-based diet. The major source of cadmium contamination was attributed to the calcium supplement used for diet formulation. Comparative analyses of two purified diet samples and one cereal-based diet by the National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards) and the National Center for Toxicological Research (NCTR) gave virtuallymore » identical results for Cd. A comparative study of Cd levels determined by flame and furnace AAS was also made by the NCTR and the NIST.« less
Support Documents for EPA’s Second Review of Existing Drinking Water Standards
The support documents for the Six-Year Review 2 of existing National Primary Drinking Water Standards contain extensive information including protocol for the review, and chemical contaminant health effects among others
Support Documents for EPA’s Third Review of Existing Drinking Water Standards
The support documents for the Six-Year Review 3 of existing National Primary Drinking Water Standards contain extensive information including protocol for the review, and chemical contaminant health effects among others
Standardizing CT lung density measure across scanner manufacturers.
Chen-Mayer, Huaiyu Heather; Fuld, Matthew K; Hoppel, Bernice; Judy, Philip F; Sieren, Jered P; Guo, Junfeng; Lynch, David A; Possolo, Antonio; Fain, Sean B
2017-03-01
Computed Tomography (CT) imaging of the lung, reported in Hounsfield Units (HU), can be parameterized as a quantitative image biomarker for the diagnosis and monitoring of lung density changes due to emphysema, a type of chronic obstructive pulmonary disease (COPD). CT lung density metrics are global measurements based on lung CT number histograms, and are typically a quantity specifying either the percentage of voxels with CT numbers below a threshold, or a single CT number below which a fixed relative lung volume, nth percentile, falls. To reduce variability in the density metrics specified by CT attenuation, the Quantitative Imaging Biomarkers Alliance (QIBA) Lung Density Committee has organized efforts to conduct phantom studies in a variety of scanner models to establish a baseline for assessing the variations in patient studies that can be attributed to scanner calibration and measurement uncertainty. Data were obtained from a phantom study on CT scanners from four manufacturers with several protocols at various tube potential voltage (kVp) and exposure settings. Free from biological variation, these phantom studies provide an assessment of the accuracy and precision of the density metrics across platforms solely due to machine calibration and uncertainty of the reference materials. The phantom used in this study has three foam density references in the lung density region, which, after calibration against a suite of Standard Reference Materials (SRM) foams with certified physical density, establishes a HU-electron density relationship for each machine-protocol. We devised a 5-step calibration procedure combined with a simplified physical model that enabled the standardization of the CT numbers reported across a total of 22 scanner-protocol settings to a single energy (chosen at 80 keV). A standard deviation was calculated for overall CT numbers for each density, as well as by scanner and other variables, as a measure of the variability, before and after the standardization. In addition, a linear mixed-effects model was used to assess the heterogeneity across scanners, and the 95% confidence interval of the mean CT number was evaluated before and after the standardization. We show that after applying the standardization procedures to the phantom data, the instrumental reproducibility of the CT density measurement of the reference foams improved by more than 65%, as measured by the standard deviation of the overall mean CT number. Using the lung foam that did not participate in the calibration as a test case, a mixed effects model analysis shows that the 95% confidence intervals are [-862.0 HU, -851.3 HU] before standardization, and [-859.0 HU, -853.7 HU] after standardization to 80 keV. This is in general agreement with the expected CT number value at 80 keV of -855.9 HU with 95% CI of [-857.4 HU, -854.5 HU] based on the calibration and the uncertainty in the SRM certified density. This study provides a quantitative assessment of the variations expected in CT lung density measures attributed to non-biological sources such as scanner calibration and scanner x-ray spectrum and filtration. By removing scanner-protocol dependence from the measured CT numbers, higher accuracy and reproducibility of quantitative CT measures were attainable. The standardization procedures developed in study may be explored for possible application in CT lung density clinical data. © 2017 American Association of Physicists in Medicine.
Virji, M Abbas; Woskie, Susan R; Pepper, Lewis D
2009-02-01
A 2005 regulatory review of the lead in construction standard by the Occupational Safety and Health Administration (OSHA) noted that alternative pathways of exposure can be as significant as inhalation exposure and that noncompliance with the standard pertaining to hygiene facilities and practices was the second most commonly violated section of the standard. Noncompliance with provisions of the standard and unhealthy work and hygiene practices likely increase the likelihood of take-home lead via contaminated clothing, automobiles, and skin, thus contributing to elevated blood lead levels (BLL) among construction workers and their family members. We performed a cross-sectional study of bridge painters working for small contractors in Massachusetts to investigate causes of persistent elevated BLLs and to assess lead exposures. Thirteen work sites were evaluated for a 2-week period during which surface and skin wipe samples were collected and qualitative information was obtained on personal hygiene practices, decontamination and hand wash facilities, and respiratory protection programs. Results showed lead contamination on workers' skin, respirators, personal automobiles, and the decontamination unit, indicating a significant potential for take-home lead exposure. Overall, the geometric mean (GM) skin lead levels ranged from 373 microg on workers' faces at end of shift to 814 microg on hands at break time. The overall GM lead level inside respirators was 143 microg before work and 286 microg after work. Lead contamination was also present inside workers' personal vehicles as well as on surfaces inside the clean side of the decontamination unit. Review of the respiratory protection programs, work site decontamination and hand wash facilities, and personal hygiene practices indicated that these factors had significant impact on skin and surface contamination levels and identified significant opportunities for improving work site facilities and personal practices. Elevated lead exposure and BLL can be minimized by strict adherence to the OSHA provisions for functioning decontamination and hygiene facilities and healthy personal hygiene practices.
Gallas-Lindemann, Carmen; Sotiriadou, Isaia; Mahmoodi, Mohammad Reza; Karanis, Panagiotis
2013-02-01
Human toxoplasmosis is potentially contracted due to consumption of contaminated drinking water and represents an increasing public health risk worldwide. Toxoplasma gondii oocysts can be resistant to standard disinfection processes, including UV radiation. Increased awareness of the risk of waterborne toxoplasmosis outbreaks has led to an increase in research interest in the detection of oocysts in environmental water systems. Ninety-five environmental water samples from the Lower Rhine area in Germany have been included in the study and examined for the presence of Toxoplasma. Water samples were filtered or flocculated by aluminum sulfate and purified by sucrose density gradient. DNA was then extracted, and the DNA samples were then examined by LAMP analysis. T. gondii DNA was detected in eight out of 83 (9.6%) influent and effluent samples obtained from wastewater treatment plants. All samples (n=12) from the surface, ground, raw and tap waters tested negative. The purpose of this work was to investigate the occurrence and distribution of Toxoplasma oocysts on the Lower Rhine in Germany. Our study provides evidence that the assay is a sensitive, specific, rapid and cost effective method for the detection of T. gondii and is useful for both the investigations of cases of waterborne outbreaks and for identifying the source of contamination. Copyright © 2012 Elsevier B.V. All rights reserved.
Melville, G E
1995-01-01
Island Lake, Saskatchewan, has become eutrophic, subsaline (salinity between 0.5 and 3.0 g I(-1)) and contaminated with several metals over the last decade. In this study, the crustacean zooplankton community in the lake in early summer 1989 is compared to the community during the early summers of the baseline years 1978 and 1979, based on archived environmental impact assessment samples. Community composition has changed, probably because of salinization and perhaps, to a lesser extent, eutrophication. Calanoid copepods have disappeared, while the numbers of species of cyclopoid copepods and cladocerans have increased. Ceriodaphnia reticulata, present in 1988 only, was more numerous than any other species during all three years. Densities of all other species were very low in 1989, which has led to lower diversity (Simpsons Index). Predation by Chaoborus probably contributed to the low abundances in 1989. The characteristics of the zooplankton community in 1989 were very similar to those of zooplankton in culturally acidified lakes, and indicate that Island Lake is in poor health. The success of Ceriodaphnia, a standard toxicity bioassay genus, is noteworthy under such contaminated conditions. While the taxonomic changes are obvious, the zooplankton data are limited; therefore causes can only be inferred. The study demonstrates the need for more and better ecosystem-specific biological information in order to do environmental impact assessments, in this case for mining in the north.
NASA Astrophysics Data System (ADS)
Wrable-Rose, Madeline; Primera-Pedrozo, Oliva M.; Pacheco-Londoño, Leonardo C.; Hernandez-Rivera, Samuel P.
2010-12-01
This research examines the surface contamination properties, trace sample preparation methodologies, detection systems response and generation of explosive contamination standards for trace detection systems. Homogeneous and reproducible sample preparation is relevant for trace detection of chemical threats, such as warfare agents, highly energetic materials (HEM) and toxic industrial chemicals. The objective of this research was to develop a technology capable of producing samples and standards of HEM with controlled size and distribution on a substrate to generate specimens that would reproduce real contamination conditions. The research activities included (1) a study of the properties of particles generated by two deposition techniques: sample smearing deposition and inkjet deposition, on gold-coated silicon, glass and stainless steel substrates; (2) characterization of composition, distribution and adhesion characteristics of deposits; (3) evaluation of accuracy and reproducibility for depositing neat highly energetic materials such as TNT, RDX and ammonium nitrate; (4) a study of HEM-surface interactions using FTIR-RAIRS; and (5) establishment of protocols for validation of surface concentration using destructive methods such as HPLC.
Widmann, Gerlig; Al-Shawaf, Reema; Schullian, Peter; Al-Sadhan, Ra'ed; Hörmann, Romed; Al-Ekrish, Asma'a A
2017-05-01
Differences in noise and density values in MDCT images obtained using ultra-low doses with FBP, ASIR, and MBIR may possibly affect implant site density analysis. The aim of this study was to compare density and noise measurements recorded from dental implant sites using ultra-low doses combined with FBP, ASIR, and MBIR. Cadavers were scanned using a standard protocol and four low-dose protocols. Scans were reconstructed using FBP, ASIR-50, ASIR-100, and MBIR, and either a bone or standard reconstruction kernel. Density (mean Hounsfield units [HUs]) of alveolar bone and noise levels (mean standard deviation of HUs) was recorded from all datasets and measurements were compared by paired t tests and two-way ANOVA with repeated measures. Significant differences in density and noise were found between the reference dose/FBP protocol and almost all test combinations. Maximum mean differences in HU were 178.35 (bone kernel) and 273.74 (standard kernel), and in noise, were 243.73 (bone kernel) and 153.88 (standard kernel). Decreasing radiation dose increased density and noise regardless of reconstruction technique and kernel. The effect of reconstruction technique on density and noise depends on the reconstruction kernel used. • Ultra-low-dose MDCT protocols allowed more than 90 % reductions in dose. • Decreasing the dose generally increased density and noise. • Effect of IRT on density and noise varies with reconstruction kernel. • Accuracy of low-dose protocols for interpretation of bony anatomy not known. • Effect of low doses on accuracy of computer-aided design models unknown.
NASA Technical Reports Server (NTRS)
Simon, C. G.; Buonaquisti, A. J.; Batchelor, D. A.; Hunter, J. L.; Griffis, D. P.; Misra, V.; Ricks, D. R.; Wortman, J. J.; Brownlee, D. E.; Best, S. R.
1995-01-01
Two dimensional elemental ion maps have been recorded for hundreds of microparticle impact sites and contamination features on LDEF surfaces. Since the majority of the analyzed surfaces were metal-oxide-silicon (MOS) impact detectors from the Interplanetary Dust Experiment, a series of 'standard' and 'blank' analyses of these surfaces are included. Hypervelocity impacts of forsterite olivine microparticles on activated flight sensors served as standards while stylus and pulsed laser simulated 'impacts' served as analytical blanks. Results showed that despite serious contamination issues, impactor residues can be identified in greater than 1/3 of the impact sites. While aluminum oxide particles could not be detected on aluminum surfaces, they were detected on germanium surfaces from row 12. Remnants of manmade debris impactors consisting of paint chips and bits of metal were identified on surfaces from LDEF Rows 3 (west or trailing side), 6 (south), 9 (ram or leading side), 12 (north) and the space end. Higher than expected ratios of manmade microparticle impacts to total microparticle impacts were found on the space end and the trailing side. These results were consistent with time-tagged and time-segregated microparticle impact data from the IDE and other LDEF experiments. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences include pre-, post and inflight deposited surface contaminants as well as indigenous heterogeneous material contaminants. Non-flight contaminations traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF, even on a micro scale. In-flight deposited (low velocity) contaminants include urine droplets and bits of metal film from eroded thermal blankets.
Olafsdottir, Lovisa B; Wright, Sharon B; Smithey, Anne; Heroux, Riley; Hirsch, Elizabeth B; Chen, Alice; Lane, Benjamin; Sawhney, Mandeep S; Snyder, Graham M
2017-06-01
OBJECTIVE The aim of this study was to quantify the correlation between adenosine triphosphate (ATP) measurements and bacterial cultures from duodenoscopes for evaluation of contamination following high-level disinfection. DESIGN Duodenoscopes used for any intended endoscopic retrograde cholangiopancreatography (ERCP) procedure were included. Microbiologic and ATP data were collected concomitantly and in the same manner from ERCP duodenoscopes. SETTING A high-volume endoscopy unit at a tertiary referral acute-care facility. METHODS Duodenoscopes were sampled for ATP and bacterial contamination in a contemporaneous and highly standardized fashion using a "flush-brush-flush" method for the working channel (WC) and a dry flocked swab for the elevator mechanism (EM). Specimens were processed for any aerobic bacterial growth (colony-forming units, CFU). Growth of CFU>0 and ATP relative light unit (RLU)>0 was considered a contaminated result. Frequency of discord between among WC and EM measurements were calculated using 2×2 contingency tables. The Spearman correlation coefficient was used to calculate the relatedness of bacterial contamination and ATP as continuous measurements. RESULTS The Spearman correlation coefficient did not demonstrate significant relatedness between ATP and CFU for either a WC or EM site. Among 390 duodenoscope sampling events, ATP and CFU assessments of contamination were discordant in 82 of 390 WC measurements (21%) and 331 of 390 of EM measurements (84.9%). The EM was frequently and markedly positive by ATP measurement. CONCLUSION ATP measurements correlate poorly with a microbiologic standard assessing duodenoscope contamination, particularly for EM sampling. ATP may reflect biological material other than nonviable aerobic bacteria and may not serve as an adequate marker of bacterial contamination. Infect Control Hosp Epidemiol 2017;38:678-684.
NASA Technical Reports Server (NTRS)
Jones, W. L., Jr.; Cross, A. E.
1972-01-01
Unique plasma diagnostic measurements at high altitudes from two geometrically similar blunt body reentry spacecraft using electrostatic probe rakes are presented. The probes measured the positive ion density profiles (shape and magnitude) during the two flights. The probe measurements were made at eight discrete points (1 cm to 7 cm) from the vehicle surface in the aft flow field of the spacecraft over the altitude range of 85.3 to 53.3 km (280,000 to 175,000 ft) with measured densities of 10 to the 8th power to 10 to the 12th power electrons/cu cm, respectively. Maximum reentry velocity for each spacecraft was approximately 7620 meters/second (25,000 ft/sec). In the first flight experiment, water was periodically injected into a flow field which was contaminated by ablation products from the spacecraft nose region. The nonablative nose of the second spacecraft thereby minimized flow field contamination. Comparisons of the probe measured density profiles with theoretical calculations are presented with discussion as to the probable cause of significant disagreement. Also discussed are the correlation of probe measurements with vehicle angle of attack motions and the good high altitude agreement between electron densities inferred from the probe measurements, VHF antenna measurements, and microwave reflectometer diagnostic measurements.
NASA Astrophysics Data System (ADS)
Hoang, H.; Røed, K.; Bekkeng, T. A.; Trondsen, E.; Clausen, L. B. N.; Miloch, W. J.; Moen, J. I.
2017-11-01
A method for evaluating electron density using a single fixed-bias Langmuir probe is presented. The technique allows for high-spatio-temporal resolution electron density measurements, which can be effectively carried out by tiny spacecraft for multi-point observations in the ionosphere. The results are compared with the multi-needle Langmuir probe system, which is a scientific instrument developed at the University of Oslo comprising four fixed-bias cylindrical probes that allow small-scale plasma density structures to be characterized in the ionosphere. The technique proposed in this paper can comply with the requirements of future small-sized spacecraft, where the cost-effectiveness, limited space available on the craft, low power consumption and capacity for data-links need to be addressed. The first experimental results in both the plasma laboratory and space confirm the efficiency of the new approach. Moreover, detailed analyses on two challenging issues when deploying the DC Langmuir probe on a tiny spacecraft, which are the limited conductive area of the spacecraft and probe surface contamination, are presented in the paper. It is demonstrated that the limited conductive area, depending on applications, can either be of no concern for the experiment or can be resolved by mitigation methods. Surface contamination has a small impact on the performance of the developed probe.
Sampling Error in Relation to Cyst Nematode Population Density Estimation in Small Field Plots.
Župunski, Vesna; Jevtić, Radivoje; Jokić, Vesna Spasić; Župunski, Ljubica; Lalošević, Mirjana; Ćirić, Mihajlo; Ćurčić, Živko
2017-06-01
Cyst nematodes are serious plant-parasitic pests which could cause severe yield losses and extensive damage. Since there is still very little information about error of population density estimation in small field plots, this study contributes to the broad issue of population density assessment. It was shown that there was no significant difference between cyst counts of five or seven bulk samples taken per each 1-m 2 plot, if average cyst count per examined plot exceeds 75 cysts per 100 g of soil. Goodness of fit of data to probability distribution tested with χ 2 test confirmed a negative binomial distribution of cyst counts for 21 out of 23 plots. The recommended measure of sampling precision of 17% expressed through coefficient of variation ( cv ) was achieved if the plots of 1 m 2 contaminated with more than 90 cysts per 100 g of soil were sampled with 10-core bulk samples taken in five repetitions. If plots were contaminated with less than 75 cysts per 100 g of soil, 10-core bulk samples taken in seven repetitions gave cv higher than 23%. This study indicates that more attention should be paid on estimation of sampling error in experimental field plots to ensure more reliable estimation of population density of cyst nematodes.
Dissipation-induced dipole blockade and antiblockade in driven Rydberg systems
NASA Astrophysics Data System (ADS)
Young, Jeremy T.; Boulier, Thomas; Magnan, Eric; Goldschmidt, Elizabeth A.; Wilson, Ryan M.; Rolston, Steven L.; Porto, James V.; Gorshkov, Alexey V.
2018-02-01
We study theoretically and experimentally the competing blockade and antiblockade effects induced by spontaneously generated contaminant Rydberg atoms in driven Rydberg systems. These contaminant atoms provide a source of strong dipole-dipole interactions and play a crucial role in the system's behavior. We study this problem theoretically using two different approaches. The first is a cumulant expansion approximation, in which we ignore third-order and higher connected correlations. Using this approach for the case of resonant drive, a many-body blockade radius picture arises, and we find qualitative agreement with previous experimental results. We further predict that as the atomic density is increased, the Rydberg population's dependence on Rabi frequency will transition from quadratic to linear dependence at lower Rabi frequencies. We study this behavior experimentally by observing this crossover at two different atomic densities. We confirm that the larger density system has a smaller crossover Rabi frequency than the smaller density system. The second theoretical approach is a set of phenomenological inhomogeneous rate equations. We compare the results of our rate-equation model to the experimental observations [E. A. Goldschmidt et al., Phys. Rev. Lett. 116, 113001 (2016), 10.1103/PhysRevLett.116.113001] and find that these rate equations provide quantitatively good scaling behavior of the steady-state Rydberg population for both resonant and off-resonant drives.
The development of a 6 to 7 MeV photon field for instrument calibration
NASA Astrophysics Data System (ADS)
Duvall, K. C.; Soares, C. G.; Heaton, H. T.; Seltzer, S. M.
1985-05-01
A photon source has been developed at the National Bureau of Standards to measure the response of radiological survey instruments to high-energy photons. The 19F(p, αγ) 16 O reaction has been used to produce a 6 to 7 MeV photon field with a fairly uniform photon flux density of approximately 3 × 10 3 cm -2 s -1 at one meter from the source. The photon flux density is obtained from measurements with a 3 × 3 inch 2 Nal detector whose absolute response has been determined by a Monte Carlo calculation. The spectral characteristics of the high-energy photons have been determined from measurements with a large volume high purity germanium detector. The absorbed dose rate to water was measured with LiF thermoluminescent dosimeters (TLDs) at several depths in a 30 × 30 × 30 cm 3 Lucite phantom. It is planned to compare absorbed dose determinations from the TLD measurements with those computed from spectral measurements. The response of six commercial radiological survey instruments has been measured behind various thicknesses of plastic absorber. The results indicate that approximately 2.5 cm of plastic in front of these instruments is sufficient to discriminate against the associated high-energy electron contamination.
NASA Astrophysics Data System (ADS)
Miller, C. J.; Yoder, T. S.
2010-06-01
Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that found on canvas or denim, suede leather such as might be found on jackets, purses, or shoes, and painted metal obtained from a car hood at a junk yard. The samples were not pre-cleaned prior to testing and contained sizing agents, and in the case of the metal, oil and dirt. The substrates were photographed using a Zeiss Discover V12 stereoscope with Axiocam ICc1 3 megapixel digital camera to determine the difference in the crystalline structure and surface contamination in an attempt to determine differences and similarities associated with current contamination deposition techniques. Some samples were analyzed using scanning electron microscopy (SEM) and some were extracted and analyzed with high performance liquid chromatography (HPLC) or gas chromatography with an electron capture detector (GC-ECD) to quantify the data.
2009-03-01
sediment. The plastic limit for the samples tested averaged to 43.4 percent while the liquid limit was 77.7 percent. As discussed above, the sediment...sediment from the drums, clean it of debris such as plastic , clam shells, sticks, etc., mix to a density to be maintained consistently among all... pollutant loading to aquatic ecosystems has decreased in the past decades, contaminated sediments have shifted from a sink to a potential source of
NASA Astrophysics Data System (ADS)
Torres Torres, N. I.; Padilla, I. Y.
2015-12-01
Karst aquifers are characterized by caves, springs, and sinkholes, and typified by interconnected fissures, fractures and conduits. These characteristics make these aquifers highly productive, and vulnerable to contamination. Previous studies in the northern karst aquifers of Puerto Rico have shown significant distribution of contaminants, including volatile organic compounds, phthalates and other contaminants of emerging concern, beyond demarked sources of contamination. This study develops spatial-temporal distributions of phthalate contaminants in the karst system of northern Puerto Rico and assesses statistical correlations between hydrogeologic factors and groundwater contamination with phthalates. Geographic Information Systems (GIS) tools and technologies, and statistical models are applied to attain these objectives. Results show that there is an extensive contamination with phthalates that varies with time. Contamination is present in the confined and shallow aquifers. Di-(2-ethylhexyl) phthalate (DEHP) is the most detected contaminant (20.6% of the sites). Diethyl phthalate and and dibutyl phthalate are also detected in 6.7% and 8.24% of the sites, respectively. Phthalates detected as mixtures components are significantly detected in areas of high urban and industrial development. They are also detected in areas within 5 miles of superfund sites and landfills. The results indicate that phthalate contamination is highly related to land use. Statistical models show that the hydraulic conductivity of the aquifers, sinkholes density, and time are significantly related to the presence of phthalates in groundwater. The extensive spatio-temporal contamination suggests that contaminants can persist in the environment for long periods of time, and that land use and hydrogeological factors are important factors contributing to the presence of emerging contaminants in karst systems.
Application of Trophic Magnification Factors (TMFs) Under the ...
Directive 2013/39/EU amending and updating the Water Framework Directive (2000/60/EC) and its Daughter Directive (the so-called EQS Directive: 2008/105/EC) sets Environmental Quality Standards for biota (EQSbiota) for a number of bioaccumulative chemicals which can pose a threat to both aquatic wildlife (piscivorous birds and mammals) and human health via the consumption of contaminated prey or the intake of contaminated food originating from the aquatic environment. Member States (MS) of the European Union will need to establish programs to monitor the concentration of 11 priority substances in biota and assess compliance against these new standards for surface water classification. The biota standards essentially refer to fish and should be applied to the trophic level (TL) at which contaminant concentrations peak, so that the predator of the species at that TL is exposed to the highest contaminant levels in its food. For chemicals that are subject to biomagnification, the peak concentrations are theoretically attained at TL 3 to 4 in freshwater food webs and TL 5 in marine food webs, where the risk of secondary poisoning of top predators should also be considered. An EU-wide guidance effectively addresses the implementation of EQSbiota (EC 2014). Flexibility is allowed in the choice of target species used for monitoring because of the diversity of both habitats and aquatic community composition across Europe. According to that guidance, the consistency and co
Alvarez, D.A.; Stackelberg, P.E.; Petty, J.D.; Huckins, J.N.; Furlong, E.T.; Zaugg, S.D.; Meyer, M.T.
2005-01-01
Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.
NASA Astrophysics Data System (ADS)
Cardoso, P. G.; Sousa, E.; Matos, P.; Henriques, B.; Pereira, E.; Duarte, A. C.; Pardal, M. A.
2013-09-01
The effects of mercury contamination on the population structure and dynamics of the gastropod Peringia ulvae (also known as Hydrobia ulvae) and its impact on the trophic web were assessed along a mercury gradient in Ria de Aveiro (Portugal). The gastropod was revealed to be a tolerant species to the contaminant, since the highest densities, biomasses and growth productivity values were recorded at the intermediate contaminated area followed by the most contaminated one and finally the least contaminated area. P. ulvae was however negatively affected by mercury in terms of growth and life span. So, in the most contaminated area the population was characterised mainly by the presence of juveniles and young individuals. The intermediate contaminated area showed a greater equilibrium in terms of groups' proportion, being the adults the dominant set. The least contaminated area presented intermediate values. P. ulvae life spans were shortest in the most contaminated area (7-8 mo), followed by the least contaminated area (10-11 mo) and finally, the intermediate one (11-14 mo). P. ulvae revealed to be an important vehicle of mercury transfer from sediments to the trophic web, incorporating approximately 15 g of Hg, annually, in the inner area of the Laranjo Bay (0.6 Km2). Therefore, despite P. ulvae being revealed to be not a good bio-indicator of mercury contamination, since it did not suffer profound modifications in its structure and functioning, it is a crucial element in the mercury biomagnification processes throughout the food web.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Hassel, J.H.; Ney, J.J.; Garling, D.L.
1979-11-01
The distribution of contaminating waste products, particularly heavy metals, to the roadside ecosystem is cause for considerable concern, due to both the documented toxicity of these metals at low concentrations and their accumulation by resident organisms. The elements of major concern are lead from gasoline engine exhsuts, nickel from both diesel fuel and lubricating oil, and cadmium and zinc from rubber tires. Lead has been correlated to traffic density in various components of the terrestrial ecosystem. Similar results were reported for nickel, cadmium, and zinc, as well as lead. Information concerning concentration of heavy metals in roadside aquatic ecosystems ismore » very limited. To provide an initial assessment of contamination from this source, we determined seasonal concentrations of heavy metals in stream sediment as related to traffic density. Heavy metals entering the stream ecosystem in runoff are rapidly adsorbed to sediment, providing a stable indicator of local contamination. Analysis of seasonal change in the heavy metal load of the sediment provides insight concerning the importance of runoff relative to sediment-water interaction and uptake by other componenets of the system.« less
de Silva, Nayana Dilini Gardiyehewa; Cholewa, Ewa; Ryser, Peter
2012-10-01
The effects of heavy metal stress, drought stress, and their combination on xylem structure in red maple (Acer rubrum) seedlings were investigated in an outdoor pot experiment. As metal-contaminated substrate, a mixture of 1.5% slag with sand was used, with Ni, Cu, Co, and Cr as the main contaminants. Plants grown on contaminated substrate had increased leaf metal concentrations. The two stresses reduced plant growth in an additive manner. The effects of metal and drought stresses on xylem characteristics were similar to each other, with a reduced proportion of xylem tissue, reduced conduit density in stems, and reduced conduit size in the roots. This resulted, in both stems and roots, in reductions in hydraulic conductance, xylem-specific conductivity, and leaf-specific conductivity. The similarity of the responses to the two stresses suggests that the plants' response to metals was actually a drought response, probably due to the reduced water uptake capacity of the metal-exposed roots. The only plant responses specific to metal stress were decreasing trends of stomatal density and chlorophyll content. In conclusion, the exposure to metals aggravates water stress in an additive manner, making the plants more vulnerable to drought.
NASA Astrophysics Data System (ADS)
Schneider, N.; Ossenkopf, V.; Csengeri, T.; Klessen, R. S.; Federrath, C.; Tremblin, P.; Girichidis, P.; Bontemps, S.; André, Ph.
2015-03-01
Column-density maps of molecular clouds are one of the most important observables in the context of molecular cloud- and star-formation (SF) studies. With the Herschel satellite it is now possible to precisely determine the column density from dust emission, which is the best tracer of the bulk of material in molecular clouds. However, line-of-sight (LOS) contamination from fore- or background clouds can lead to overestimating the dust emission of molecular clouds, in particular for distant clouds. This implies values that are too high for column density and mass, which can potentially lead to an incorrect physical interpretation of the column density probability distribution function (PDF). In this paper, we use observations and simulations to demonstrate how LOS contamination affects the PDF. We apply a first-order approximation (removing a constant level) to the molecular clouds of Auriga and Maddalena (low-mass star-forming), and Carina and NGC 3603 (both high-mass SF regions). In perfect agreement with the simulations, we find that the PDFs become broader, the peak shifts to lower column densities, and the power-law tail of the PDF for higher column densities flattens after correction. All corrected PDFs have a lognormal part for low column densities with a peak at Av ~ 2 mag, a deviation point (DP) from the lognormal at Av(DP) ~ 4-5 mag, and a power-law tail for higher column densities. Assuming an equivalent spherical density distribution ρ ∝ r- α, the slopes of the power-law tails correspond to αPDF = 1.8, 1.75, and 2.5 for Auriga, Carina, and NGC 3603. These numbers agree within the uncertainties with the values of α ≈ 1.5,1.8, and 2.5 determined from the slope γ (with α = 1-γ) obtained from the radial column density profiles (N ∝ rγ). While α ~ 1.5-2 is consistent with a structure dominated by collapse (local free-fall collapse of individual cores and clumps and global collapse), the higher value of α > 2 for NGC 3603 requires a physical process that leads to additional compression (e.g., expanding ionization fronts). From the small sample of our study, we find that clouds forming only low-mass stars and those also forming high-mass stars have slightly different values for their average column density (1.8 × 1021 cm-2 vs. 3.0 × 1021 cm-2), and they display differences in the overall column density structure. Massive clouds assemble more gas in smaller cloud volumes than low-mass SF ones. However, for both cloud types, the transition of the PDF from lognormal shape into power-law tail is found at the same column density (at Av ~ 4-5 mag). Low-mass and high-mass SF clouds then have the same low column density distribution, most likely dominated by supersonic turbulence. At higher column densities, collapse and external pressure can form the power-law tail. The relative importance of the twoprocesses can vary between clouds and thus lead to the observed differences in PDF and column density structure. Appendices are available in electronic form at http://www.aanda.orgHerschel maps as FITS files are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/575/A79
Methods for Environments and Contaminants: Criteria Air Pollutants
EPA’s Office of Air Quality Planning and Standards (OAQPS) has set primary (health-based) National Ambient Air Quality Standards (NAAQS) for six common air pollutants, often referred to as criteria air pollutants (or simply criteria pollutants).
Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe
2016-08-01
Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Permeable reactive barriers (PRBs) for the restoration of contaminated ground water are no longer innovative. PRBs have evolved from innovative to accepted, standard practice, for the containment and treatment of a variety of contaminants in ground water. Like any remedial tech...
9 CFR 113.28 - Detection of mycoplasma contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REQUIREMENTS Standard Procedures § 113.28 Detection of mycoplasma contamination. The heart infusion test, using heart infusion broth and heart infusion agar, provided in this section shall be conducted when a test... inactivated at 56 °C for 30 minutes. (b) Heart infusion broth shall be prepared as provided in this paragraph...
Tribological Technology. Volume II.
1982-09-01
rolling bearings, gears, and sliding bearings produce distinctive particles. An atlas of such particles is available2 9 . Atlases of characteristic...Gravitational methods cover both sedimentation and elutration techniques. Inertial type separators perform cyclonic classification. Ferrography is the...generated after each size exposure of contaminant. This can be done today using Ferrography . Standard contaminant sensitivity tests require test
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-23
... where there is a risk of sediment contamination. List of Subjects in 7 CFR Part 58 Dairy products, Food... manufacturing plants. All of the dairy manufacturing plants utilizing the program would be considered small... systems that provide no opportunity for sediment contamination. Because milk production predominantly...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... 400 dairy manufacturing plants. All of the dairy manufacturing plants utilizing the program would be... contamination. Because milk production predominantly occurs in clean, modern facilities, using sealed lines... for those producers using cans for milk collection where there is a risk of sediment contamination...
Groundwater Molybdenum from Emerging Industries in Taiwan.
Tsai, Kuo-Sheng; Chang, Yu-Min; Kao, Jimmy C M; Lin, Kae-Long
2016-01-01
This study determined the influence of emerging industries development on molybdenum (Mo) groundwater contamination. A total of 537 groundwater samples were collected for Mo determination, including 295 samples from potentially contaminated areas of 3 industrial parks in Taiwan and 242 samples from non-potentially contaminated areas during 2008-2014. Most of the high Mo samples are located downstream from a thin film transistor-liquid crystal display (TFT-LCD) panel factory. Mean groundwater Mo concentrations from potentially contaminated areas (0.0058 mg/L) were significantly higher (p < 0.05) than those from non-potentially contaminated areas (0.0022 mg/L). The highest Mo wastewater concentrations in the effluent from the optoelectronics industry and following wastewater batch treatment were 0.788 and 0.0326 mg/L, respectively. This indicates that wastewater containing Mo is a possible source of both groundwater and surface water contamination. Nine samples of groundwater exceed the World Health Organization's suggested drinking water guideline of 0.07 mg/L. A non-carcinogenic risk assessment for Mo in adults and children using the Mo concentration of 0.07 mg/L yielded risks of 0.546 and 0.215, respectively. These results indicate the importance of the development of a national drinking water quality standard for Mo in Taiwan to ensure safe groundwater for use. According to the human health risk calculation, the groundwater Mo standard is suggested as 0.07 mg/L. Reduction the discharge of Mo-contaminated wastewater from factories in the industrial parks is also the important task in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This decision document (Record of Decision), presents the selected Remedial Action for the Operable Unit Two for the T H Agriculture & Nutrition (THAN) Site, Albany, Georgia. The second operable unit addresses the source of the contamination on the eastern parcel of the Site. The major components of the selected remedy for operable unit two include: the excavation of all soil contaminated with organics necessary to meet performance standards; the staging and preconditioning of soil for low temperature thermal desorption treatment; the treatment of excavated soil by low temperature thermal desorption; the placement of treated, decontaminated soil back to themore » site; periodic sampling of treated soil during the treatment process to verify the effectiveness of the remedy; air monitoring to ensure safety of nearby residents and workers; groundwater monitoring to ensure that metals contaminated remaining in the subsurface soil will not result in contaminated groundwater migrating offsite in concentrations which exceed groundwater protection standards; and deed restrictions to prevent residential use of the property.« less
Public health risk assessment of groundwater contamination in Batman, Turkey.
Nalbantcilar, M Tahir; Pinarkara, Sukru Yavuz
2016-08-01
In this study, a comprehensive analysis of groundwater was performed to assess contamination and phenol content in Batman, Turkey, particularly in residential areas near agriculture, livestock and oil industry facilities. From these areas, where potentially contaminated groundwater used for drinking and irrigation threatens public health, 30 groundwater samples were collected and analyzed for heavy metal concentrations (Al, As, B, Ba, Ca, Cd, Cl, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Na, Ni, NO3, P, Pb, phenol, S, Sb, Se, SO4, Sr, U, and Zn). Compared with the standards of the Environmental Protection Agency, Al, Fe, and Mn concentrations in groundwater exceeded secondary drinking water regulations, NO3 concentrations were high for maximum contaminant levels, and As, Pb, and U concentrations exceeded maximum contaminant level goals in all samples. Ni, Sb, and Se concentrations also exceeded limits set by the Turkish Standards Institution. Nearly all samples revealed concentrations of Se, Sb, Hg, and phenol due to nearby petroleum refineries, oil storage plants, and agricultural and livestock areas. The results obtained from this study indicate that the groundwater in Batman contains elements in concentrations that approach or exceed limits and thus threatens public health with increased blood cholesterol, decreased blood sugar, and circulatory problems.
A contaminant-free assessment of Endogenous Retroviral RNA in human plasma
Karamitros, Timokratis; Paraskevis, Dimitrios; Hatzakis, Angelos; Psichogiou, Mina; Elefsiniotis, Ioannis; Hurst, Tara; Geretti, Anna-Maria; Beloukas, Apostolos; Frater, John; Klenerman, Paul; Katzourakis, Aris; Magiorkinis, Gkikas
2016-01-01
Endogenous retroviruses (ERVs) comprise 6–8% of the human genome. HERVs are silenced in most normal tissues, up-regulated in stem cells and in placenta but also in cancer and HIV-1 infection. Crucially, there are conflicting reports on detecting HERV RNA in non-cellular clinical samples such as plasma that suggest the study of HERV RNA can be daunting. Indeed, we find that the use of real-time PCR in a quality assured clinical laboratory setting can be sensitive to low-level proviral contamination. We developed a mathematical model for low-level contamination that allowed us to design a laboratory protocol and standard operating procedures for robust measurement of HERV RNA. We focus on one family, HERV-K HML-2 (HK2) that has been most recently active even though they invaded our ancestral genomes almost 30 millions ago. We extensively validated our experimental design on a model cell culture system showing high sensitivity and specificity, totally eliminating the proviral contamination. We then tested 236 plasma samples from patients infected with HIV-1, HCV or HBV and found them to be negative. The study of HERV RNA for human translational studies should be performed with extensively validated protocols and standard operating procedures to control the widespread low-level human DNA contamination. PMID:27640347
Suture, synthetic, or biologic in contaminated ventral hernia repair.
Bondre, Ioana L; Holihan, Julie L; Askenasy, Erik P; Greenberg, Jacob A; Keith, Jerrod N; Martindale, Robert G; Roth, J Scott; Liang, Mike K
2016-02-01
Data are lacking to support the choice between suture, synthetic mesh, or biologic matrix in contaminated ventral hernia repair (VHR). We hypothesize that in contaminated VHR, suture repair is associated with the lowest rate of surgical site infection (SSI). A multicenter database of all open VHR performed at from 2010-2011 was reviewed. All patients with follow-up of 1 mo and longer were included. The primary outcome was SSI as defined by the Centers for Disease Control and Prevention. The secondary outcome was hernia recurrence (assessed clinically or radiographically). Multivariate analysis (stepwise regression for SSI and Cox proportional hazard model for recurrence) was performed. A total of 761 VHR were reviewed for a median (range) follow-up of 15 (1-50) mo: there were 291(38%) suture, 303 (40%) low-density and/or mid-density synthetic mesh, and 167(22%) biologic matrix repair. On univariate analysis, there were differences in the three groups including ethnicity, ASA, body mass index, institution, diabetes, primary versus incisional hernia, wound class, hernia size, prior VHR, fascial release, skin flaps, and acute repair. The unadjusted outcomes for SSI (15.1%; 17.8%; 21.0%; P = 0.280) and recurrence (17.8%; 13.5%; 21.5%; P = 0.074) were not statistically different between groups. On multivariate analysis, biologic matrix was associated with a nonsignificant reduction in both SSI and recurrences, whereas synthetic mesh associated with fewer recurrences compared to suture (hazard ratio = 0.60; P = 0.015) and nonsignificant increase in SSI. Interval estimates favored biologic matrix repair in contaminated VHR; however, these results were not statistically significant. In the absence of higher level evidence, surgeons should carefully balance risk, cost, and benefits in managing contaminated ventral hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.
Pintado-Herrera, Marina G; Lara-Martín, Pablo A; González-Mazo, Eduardo; Allan, Ian J
2016-09-01
There is a growing interest in assessing the concentration and distribution of new nonregulated organic compounds (emerging contaminants) in the environment. The measurement of freely dissolved concentrations using conventional approaches is challenging because of the low concentrations that may be encountered and their temporally variable emissions. Absorption-based passive sampling enables the estimation of freely dissolved concentrations of hydrophobic contaminants of emerging concern in water. In the present study, calibration was undertaken for 2 polymers, low-density polyethylene (LDPE) and silicone rubber for 11 fragrances, 5 endocrine-disrupting compounds, 7 ultraviolet (UV) filters, and 8 organophosphate flame retardant compounds. Batch experiments were performed to estimate contaminant diffusion coefficients in the polymers (Dp ), which in general decreased with increasing molecular weight. The values for fragrances, endocrine-disrupting compounds, and UV filters were in ranges similar to those previously reported for polycyclic aromatic hydrocarbons, but were 1 order of magnitude lower for organophosphate flame retardant compounds. Silicone rubber had higher Dp values than LDPE and was therefore selected for further experiments to calculate polymer/water partition coefficients (KPW ). The authors observed a positive correlation between log KPW and log octanol/water partition coefficient values. Field testing of silicone rubber passive samplers was undertaken though exposure in the River Alna (Norway) for an exposure time of 21 d to estimate freely dissolved concentration. Some fragrances and UV filters were predominant over other emerging and regulated contaminants, at levels up to 1600 ng L(-1) for galaxolide and 448 ng L(-1) for octocrylene. Environ Toxicol Chem 2016;35:2162-2172. © 2016 SETAC. © 2016 SETAC.
Influence of interspecific interactions on avoidance response to contamination.
Silva, Daniel C V R; Araújo, Cristiano V M; Marassi, Rodrigo J; Cardoso-Silva, Sheila; Neto, Morun B; Silva, Gilmar C; Ribeiro, Rui; Silva, Flávio T; Paiva, Teresa C B; Pompêo, Marcelo L M
2018-06-17
An increasing number of studies have shown the ability of organisms to escape from toxic effects due to contamination, by moving spatially towards less contaminated habitats. However, this issue has been investigated in monospecific scenarios, without considering possible interactions between species during the contamination avoidance process. It is widely known that the spatial distribution of one species can be affected by another one, in different ways. Therefore, the main question addressed in the present study was as follows: Might interspecific interaction between the freshwater fish Danio rerio (zebrafish) and Poecilia reticulata (guppy) change their behavior patterns in terms of avoidance in the presence of a copper gradient? Zebrafish and guppies exposed to a copper gradient were tested for avoidance responses in a free-choice, non-forced, static, multi-compartmented exposure system, using two distinct approaches: (1) monospecific tests, in which only one species was exposed to the copper gradient, at two different population densities; and (2) multispecific tests, in which both species were tested simultaneously. In the control (with no copper) monospecific tests, both species were randomly distributed; however, in the control multispecific test, P. reticulata tended to aggregate. In the monospecific tests with a copper gradient, both species avoided copper in a similar way, with AC 50 (concentration triggering avoidance in 50% of the exposed population) values between 15 and 18 μg·L -1 , irrespective of the population density. However, in the multispecific tests, P. reticulata displaced D. rerio to previously avoided copper levels, consequently increasing the AC 50 of D. rerio to 75 μg·L -1 . This study shows the importance of understanding the interactions among species in contaminated areas, and the way that one species can prevent the avoidance behavior of another. Copyright © 2018 Elsevier B.V. All rights reserved.
Nonga, Hezron Emmanuel; Ngowi, Helena Aminiel; Mdegela, Robinson Hammerthon; Mutakyawa, Eliud; Nyahinga, Gabriel Busungu; William, Robert; Mwadini, Mtumwa Mohd
2015-11-26
Raw milk, raw fruit juice and raw fish are enriched with essential nutrients for human diet but are prone to microbial contamination along the value chain. This cross sectional study was conducted to assess physicochemical characteristics and microbial quality of raw milk, fruit juice and fish from food vendors in Morogoro Municipality, Tanzania. The physicochemical assessment of food samples was done by smell, colour, presence of debris, turbidity, consistence, pH and clot on alcohol test. Hygiene of food containers, personnel and the vending environment was also assessed. Qualitative and quantitative microbial assessment of food was done using standard laboratory protocols as described by Tanzania Bureau of Standards and International Systems of Standards. Raw milk sold in Morogoro was of poor quality since was adulterated with water, contained sediments and clotted on alcohol test. Up to 63 % of the milk samples were contaminated with Escherichia coli and 60 % had higher total viable count (TVC) than the recommended values. Raw fruit juice was stored in dirty containers and sold under unhygienic environment. Seventy-three percent of juice samples had TVC beyond the recommendations while E. coli contamination rate was 63.3 %. The raw fish samples had started spoiling as depicted through sensory evaluation. E. coli contamination rate was 55 % and that of Campylobacter jejuni was 0.5 %. The mean TVC of raw fish was 8.1 (Log cfu/g) and 96.2 % of the fish samples had TVC beyond the recommended limits of 5.0 Log cfu/g. The physicochemical characteristics of food vended in Morogoro Municipality were of poor quality. The food had high bacterial contaminations. This situation poses health risks to the public and losses to food vendors due to spoilage. Stakeholders in food value chain should be educated on safe production and good hygienic practices. Routine quality and safety assessment of locally vended food, inspection of selling premises and regular health check-up of the personnel involved in food vending industry should be instituted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1999-09-01
Mercury contaminated wastes in many forms are present at various U. S. Department of Energy (DOE) sites. Based on efforts led by the Mixed Waste Focus Area (MWFA) and its Mercury Working Group (HgWG), the inventory of wastes contaminated with <260 ppm mercury and with radionuclides stored at various DOE sites is estimated to be approximately 6,000 m 3). At least 26 different DOE sites have this type of mixed low-level waste in their storage facilities. Extraction methods are required to remove mercury from waste containing >260 ppm levels, but below 260 ppm Hg contamination levels the U. S. Environmentalmore » Protection Agency (EPA) does not require removal of mercury from the waste. Steps must still be taken, however, to ensure that the final waste form does not leach mercury in excess of the limit for mercury prescribed in the Resource Conservation and Recovery Act (RCRA) when subjected to the Toxicity Characteristic Leaching Procedure (TCLP). At this time, the limit is 0.20 mg/L. However, in the year 2000, the more stringent Universal Treatment Standard (UTS) of 0.025 mg/L will be used as the target endpoint. Mercury contamination in the wastes at DOE sites presents a challenge because it exists in various forms, such as soil, sludges, and debris, as well as in different chemical species of mercury. Stabilization is of interest for radioactively contaminated mercury waste (<260 ppm Hg) because of its success with particular wastes, such as soils, and its promise of applicability to a broad range of wastes. However, stabilization methods must be proven to be adequate to meet treatment standards. It must also be proven feasible in terms of economics, operability, and safety. To date, no standard method of stabilization has been developed and proven for such varying waste types as those within the DOE complex.« less
Müller, Philip C; Senft, Jonas D; Gath, Philip; Steinemann, Daniel C; Nickel, Felix; Billeter, Adrian T; Müller-Stich, Beat P; Linke, Georg R
2018-01-01
The risk of infectious complications due to peritoneal contamination is a major concern and inhibits the widespread use of transrectal NOTES. A standardized rectal washout with a reversible colon occlusion device in situ has previously shown potential in reducing peritoneal contamination. The aim of this study was to compare the peritoneal contamination rate and inflammatory reaction for transrectal cholecystectomy after ideal rectal preparation (trCCE) and standard laparoscopic cholecystectomy (lapCCE) in a porcine survival experiment. Twenty pigs were randomized to trCCE (n = 10) or lapCCE (n = 10). Before trCCE, rectal washout was performed with saline solution. A colon occlusion device was then inserted and a second washout with povidone-iodine was performed. The perioperative course and the inflammatory reaction (leukocytes, C-reactive protein) were compared. At necropsy, 14 days after surgery the abdominal cavity was screened for infectious complications and peritoneal swabs were obtained for comparison of peritoneal contamination. Peritoneal contamination was lower after trCCE than after lapCCE (0/10 vs. 6/10; p = 0.003). No infectious complications were found at necropsy in either group and postoperative complications did not differ (p = 1.0). Immediately after the procedure, leukocytes were higher after lapCCE (17.0 ± 2.7 vs. 14.6 ± 2.3; p = 0.047). Leukocytes and C-reactive protein showed no difference in the further postoperative course. Intraoperative complications and total operation time (trCCE 114 ± 32 vs. 111 ± 27 min; p = 0.921) did not differ, but wound closure took longer for trCCE (31.5 ± 19 vs. 13 ± 5 min; p = 0.002). After standardized rectal washout with a colon occlusion device in situ, trCCE was associated without peritoneal contamination and without access-related infectious complications. Based on the findings of this study, a randomized controlled clinical study comparing clinical outcomes of trCCE with lapCCE should be conducted.
The chemical quality of self-supplied domestic well water in the United States
Focazio, M.J.; Tipton, D.; Dunkle, Shapiro S.; Geiger, L.H.
2006-01-01
Existing water quality data collected from domestic wells were summarized to develop the first national-scale retrospective of self-supplied drinking water sources. The contaminants evaluated represent a range of inorganic and organic compounds, and although the data set was not originally designed to be a statistical representation of national occurrence, it encompasses large parts of the United States including at least some wells sampled in every state and Puerto Rico. Inorganic contaminants were detected in many of the wells, and concentrations exceeded the U.S. EPA maximum contaminant levels (MCLs; federal drinking water standards used to regulate public drinking water quality) more often than organic contaminants. Of the inorganic constituents evaluated, arsenic concentrations exceeded the MCL (10 ??g/L) in ???11% of the 7580 wells evaluated, nitrate exceeded the MCL (10 mg/L) in ???8% of the 3465 wells evaluated, uranium-238 exceeded the MCL (30 ??g/L) in ???4% of the wells, and radon-222 exceeded 300 and 4000 pCi/L (potential drinking water standards currently under review by the U.S. EPA) in ???75% and 9% of the wells, respectively. The MCLs for total mercury and fluoride were each exceeded in <1% of the wells evaluated. The MCL was exceeded in <1% of all wells for all anthropogenically derived organic contaminants evaluated and was not exceeded for many contaminants. In addition, 10 contaminants evaluated do not currently have an MCL. Atrazine, however, was detected in 24% of the wells evaluated and was the most frequently detected organic contaminant of the 28 organic contaminants evaluated in this study. Simazine and metolachlor each were detected in ???9% of all wells and tied for second in frequency of detection for organic contaminants. The third and fourth most frequently detected organic contaminants were methyl tert-butyl ether (MTBE) (6%) and chloroform (5%), respectively. Because the water quality of domestic wells is not federally regulated or nationally monitored, this study provides a unique, previously nonexistent, perspective on the quality of the self-supplied drinking water resources used by ???45 million Americans in the United States. Copyright ?? 2006 The Author(s).
Krappmann, Michael; de Boer, Arjen R; Kool, Daniël R W; Irth, Hubertus; Letzel, Thomas
2016-04-30
Continuous-flow reaction detection systems (monitoring enzymatic reactions with mass spectrometry (MS)) lack quantitative values so far. Therefore, two independent internal standards (IS) are implemented in a way that the online system stability can be observed, quantitative conversion values for substrate and product can be obtained and they can be used as mass calibration standards for high MS accuracy. An application previously developed for the MS detection of peptide phosphorylation by cAMP-dependent protein kinase A (PKA) (De Boer et al., Anal. Bioanal. Chem. 2005, 381, 647-655) was transferred to a continuous-flow reaction detection system. This enzymatic reaction, involving enzyme activation as well as the transfer of a phosphate group from ATP to a peptide substrate, was used to prove the compatibility of a quantitative enzymatic assay in a continuous-flow real-time system (connected to MS). Moreover (using internal standards), the critical parameter reaction temperature (including solution density variations depending on temperature) was studied in the continuous-flow mixing system. Furthermore, two substrates (malantide and kemptide), two enzyme types (catalytic subunit of PKA and complete PKA) and one inhibitor were tested to determine system robustness and long-term availability. Even spraying solutions that contained significant amount of MS contaminants (e.g. the polluted catalytic subunit) resulted in quantifiable MS signal intensities. Subsequent recalculations using the internal standards led to results representing the power of this application. The presented methodology and the data evaluation with available Achroma freeware enable the direct coupling of biochemical assays with quantitative MS detection. Monitoring changes such as temperature, reaction time, inhibition, or compound concentrations can be observed quantitatively and thus enzymatic activity can be calculated. Copyright © 2016 John Wiley & Sons, Ltd.
Big bang nucleosynthesis - The standard model and alternatives
NASA Technical Reports Server (NTRS)
Schramm, David N.
1991-01-01
The standard homogeneous-isotropic calculation of the big bang cosmological model is reviewed, and alternate models are discussed. The standard model is shown to agree with the light element abundances for He-4, H-2, He-3, and Li-7 that are available. Improved observational data from recent LEP collider and SLC results are discussed. The data agree with the standard model in terms of the number of neutrinos, and provide improved information regarding neutron lifetimes. Alternate models are reviewed which describe different scenarios for decaying matter or quark-hadron induced inhomogeneities. The baryonic density relative to the critical density in the alternate models is similar to that of the standard model when they are made to fit the abundances. This reinforces the conclusion that the baryonic density relative to critical density is about 0.06, and also reinforces the need for both nonbaryonic dark matter and dark baryonic matter.
Verma, Vikrant; Li, Tingwen; De Wilde, Juray
2017-05-26
Vortex chambers allow the generation of rotating fluidized beds, offering high-G intensified gas-solid contact, gas-solids separation and solids-solids segregation. Focusing on binary particle mixtures and fixing the density and diameter of the heavy/large particles, transient batch CFD-coarse-grained DPM simulations were carried out with varying densities or sizes of the light/small particles to evaluate to what extent combining these three functionalities is possible within a vortex chamber of given design. Both the rate and quality of segregation were analyzed. Within a relatively wide density and size range, fast and efficient segregation takes place, with an inner and slower rotating bed ofmore » the lighter/small particles forming within the outer and faster rotating bed of the heavier/large particles. Simulations show that the contamination of the outer bed with lighter particles occurs more easily than contamination of the inner bed with heavier particles and increases with decreasing difference in size or density of the particles. Bubbling in the inner bed is observed with an inner bed of very low density or small particles. Porosity plots show that vortex chambers with a sufficient number of gas inlet slots have to be used to guarantee a uniform gas distribution and particle bed. Lastly, the flexibility of particle segregation in vortex chambers with respect to the gas flow rate is demonstrated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verma, Vikrant; Li, Tingwen; De Wilde, Juray
Vortex chambers allow the generation of rotating fluidized beds, offering high-G intensified gas-solid contact, gas-solids separation and solids-solids segregation. Focusing on binary particle mixtures and fixing the density and diameter of the heavy/large particles, transient batch CFD-coarse-grained DPM simulations were carried out with varying densities or sizes of the light/small particles to evaluate to what extent combining these three functionalities is possible within a vortex chamber of given design. Both the rate and quality of segregation were analyzed. Within a relatively wide density and size range, fast and efficient segregation takes place, with an inner and slower rotating bed ofmore » the lighter/small particles forming within the outer and faster rotating bed of the heavier/large particles. Simulations show that the contamination of the outer bed with lighter particles occurs more easily than contamination of the inner bed with heavier particles and increases with decreasing difference in size or density of the particles. Bubbling in the inner bed is observed with an inner bed of very low density or small particles. Porosity plots show that vortex chambers with a sufficient number of gas inlet slots have to be used to guarantee a uniform gas distribution and particle bed. Lastly, the flexibility of particle segregation in vortex chambers with respect to the gas flow rate is demonstrated.« less
Carrillo, M; Estrada, E; Hazen, T C
1985-01-01
The density of Bifidobacterium spp., fecal coliforms, Escherichia coli, and total anaerobic bacteria, acridine orange direct counts, percentages of total bacterial community activity and respiration, and 12 physical and chemical parameters were measured simultaneously at six sites for 12 months in the Mameyes River rain forest watershed, Puerto Rico. The densities of all bacteria were higher than those reported for uncontaminated temperate rivers, even though other water quality parameters would indicate that all uncontaminated sites were oligotrophic. The highest densities for all indicator bacteria were at the site receiving sewage effluent; however, the highest elevation site in the watershed had the next highest densities. Correlations between bacterial densities, nitrates, temperature, phosphates, and total phosphorus indicated that all viable counts were related to nutrient levels, regardless of the site sampled. In situ diffusion chamber studies at two different sites indicated that E. coli could survive, remain physiologically active, and regrow at rates that were dependent on nutrient levels of the ambient waters. Bifidobacterium adolescentis did not survive at either site but did show different rates of decline and physiological activity at the two sites. Bifidobacteria show promise as a better indicator of recent fecal contamination in tropical freshwaters than E. coli or fecal coliforms; however, the YN-6 medium did not prove to be effective for enumeration of bifidobacteria. The coliform maximum contaminant levels for assessing water usability for drinking and recreation appear to be unworkable in tropical freshwaters. PMID:3901921
First principles study of gallium cleaning for hydrogen-contaminated α-Al2O3(0001) surfaces.
Yang, Rui; Rendell, Alistair P
2013-05-15
The use of gallium for cleaning hydrogen-contaminated Al2O3 surfaces is explored by performing first principles density functional calculations of gallium adsorption on a hydrogen-contaminated Al-terminated α-Al2O3(0001) surface. Both physisorbed and chemisorbed H-contaminated α-Al2O3(0001) surfaces with one monolayer (ML) gallium coverage are investigated. The thermodynamics of gallium cleaning are considered for a variety of different asymptotic products, and are found to be favorable in all cases. Physisorbed H atoms have very weak interactions with the Al2O3 surface and can be removed easily by the Ga ML. Chemisorbed H atoms form stronger interactions with the surface Al atoms. Bonding energy analysis and departure simulations indicate, however, that chemisorbed H atoms can be effectively removed by the Ga ML. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Xu, Zexuan; Hu, Bill
2016-04-01
Dual-permeability karst aquifers of porous media and conduit networks with significant different hydrological characteristics are widely distributed in the world. Discrete-continuum numerical models, such as MODFLOW-CFP and CFPv2, have been verified as appropriate approaches to simulate groundwater flow and solute transport in numerical modeling of karst hydrogeology. On the other hand, seawater intrusion associated with fresh groundwater resources contamination has been observed and investigated in numbers of coastal aquifers, especially under conditions of sea level rise. Density-dependent numerical models including SEAWAT are able to quantitatively evaluate the seawater/freshwater interaction processes. A numerical model of variable-density flow and solute transport - conduit flow process (VDFST-CFP) is developed to provide a better description of seawater intrusion and submarine groundwater discharge in a coastal karst aquifer with conduits. The coupling discrete-continuum VDFST-CFP model applies Darcy-Weisbach equation to simulate non-laminar groundwater flow in the conduit system in which is conceptualized and discretized as pipes, while Darcy equation is still used in continuum porous media. Density-dependent groundwater flow and solute transport equations with appropriate density terms in both conduit and porous media systems are derived and numerically solved using standard finite difference method with an implicit iteration procedure. Synthetic horizontal and vertical benchmarks are created to validate the newly developed VDFST-CFP model by comparing with other numerical models such as variable density SEAWAT, couplings of constant density groundwater flow and solute transport MODFLOW/MT3DMS and discrete-continuum CFPv2/UMT3D models. VDFST-CFP model improves the simulation of density dependent seawater/freshwater mixing processes and exchanges between conduit and matrix. Continuum numerical models greatly overestimated the flow rate under turbulent flow condition but discrete-continuum models provide more accurate results. Parameters sensitivities analysis indicates that conduit diameter and friction factor, matrix hydraulic conductivity and porosity are important parameters that significantly affect variable-density flow and solute transport simulation. The pros and cons of model assumptions, conceptual simplifications and numerical techniques in VDFST-CFP are discussed. In general, the development of VDFST-CFP model is an innovation in numerical modeling methodology and could be applied to quantitatively evaluate the seawater/freshwater interaction in coastal karst aquifers. Keywords: Discrete-continuum numerical model; Variable density flow and transport; Coastal karst aquifer; Non-laminar flow
This guidance provides suggestions and perspectives on how members of the regulated community, states, and the public can demonstrate compliance with the alternative treatment standards for certain contaminated soils that will be land disposed.
Smith, Stephen B.; Anderson, Patrick J.; Baumann, Paul C.; DeWeese, Lawrence R.; Goodbred, Steven L.; Coyle, James J.; Smith, David S.
2012-01-01
The Charles River Project provided an opportunity to simultaneously deploy a combination of biomonitoring techniques routinely used by the U.S. Geological Survey National Water Quality Assessment Program, the Biomonitoring of Environmental Status and Trends Project, and the Contaminant Biology Program at an urban site suspected to be contaminated with polycyclic aromatic hydrocarbons. In addition to these standardized methods, additional techniques were used to further elucidate contaminant exposure and potential impacts of exposure on biota. The purpose of the study was to generate a comprehensive, multi-metric data set to support assessment of contaminant exposure and effects at the site. Furthermore, the data set could be assessed to determine the relative performance of the standardized method suites typically used by the National Water Quality Assessment Program and the Biomonitoring of Environmental Status and Trends Project, as well as the additional biomonitoring methods used in the study to demonstrate ecological effects of contaminant exposure. The Contaminant Effects Workgroup, an advisory committee of the U.S. Geological Survey/Contaminant Biology Program, identified polycyclic aromatic hydrocarbons as the contaminant class of greatest concern in urban streams of all sizes. The reach of the Charles River near Watertown, Massachusetts, was selected as the site for this study based on the suspected presence of polycyclic aromatic hydrocarbon contamination and the presence of common carp (Cyprinus carpio), largemouth bass (Micropterus salmoides), and white sucker (Catostomus commersoni). All of these fish have extensive contaminant-exposure profiles related to polycyclic aromatic hydrocarbons and other environmental contaminants. This project represented a collaboration of universities, Department of the Interior bureaus including multiple components of the USGS (Biological Resources Discipline and Water Resources Discipline Science Centers, the Contaminant Biology Program, and the Status and Trends of Biological Resources Program), and the U.S. Fish and Wildlife Service. Samples for analyzing water chemistry, sediment chemistry and toxicity, fish community structure, tissue chemistry, and fish (20 carp, 20 bass, and 40 white sucker) and invertebrate pathology were collected in late August, 2005. This report provides results from the analyses of fish pathology, biomarkers of exposure and effects (reproductive, carcinogenic, genotoxic, and immunologic), sediment chemistry, toxicity, and fish and invertebrate community structure.
Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'
NASA Technical Reports Server (NTRS)
Houston, Karrie
2007-01-01
The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.
Rapid immobilization of simulated radioactive soil waste by microwave sintering.
Zhang, Shuai; Shu, Xiaoyan; Chen, Shunzhang; Yang, Huimin; Hou, Chenxi; Mao, Xueli; Chi, Fangting; Song, Mianxin; Lu, Xirui
2017-09-05
A rapid and efficient method is particularly necessary in the timely disposal of seriously radioactive contaminated soil. In this paper, a series of simulated radioactive soil waste containing different contents of neodymium oxide (3-25wt.%) has been successfully vitrified by microwave sintering at 1300°C for 30min. The microstructures, morphology, element distribution, density and chemical durability of as obtained vitrified forms have been analyzed. The results show that the amorphous structure, homogeneous element distribution, and regular density improvement are well kept, except slight cracks emerge on the magnified surface for the 25wt.% Nd 2 O 3 -containing sample. Moreover, all the vitrified forms exhibit excellent chemical durability, and the leaching rates of Nd are kept as ∼10 -4 -10 -6 g/(m 2 day) within 42days. This demonstrates a potential application of microwave sintering in radioactive contaminated soil disposal. Copyright © 2017 Elsevier B.V. All rights reserved.
Thermophysical Property Measurements in the MSFC ESL
NASA Technical Reports Server (NTRS)
Hyers, R. W.; Rogers, J. R.; Robinson, M. B.; Rathz, T. J.; Curreri, Peter A. (Technical Monitor)
2002-01-01
Electrostatic Levitation (ESL) is an advanced technique for containerless processing of metals, ceramics, and semiconductors. Because no container is required, there is no contamination from reaction with a crucible, allowing processing of high temperature, highly reactive melts. The high vacuum processing environment further reduces possible contamination of the samples. Finally, there is no container to provide heterogeneous nucleation sites, so the undercooled range is also accessible for many materials. For these reasons, ESL provides a unique environment for measuring thermophysical properties of liquid materials. The properties that can be measured in ESL include density, surface tension, viscosity, electrical and thermal conductivity, specific heat, phase diagram, TTT- and CCT- curves, and other thermodynamic properties. In this paper, we present data on surface tension and viscosity, measured by the oscillating drop technique, and density, measured by an automated photographic technique, measured in the ESL at NASA Marshall Space Flight Center.
Research on solar pumped liquid lasers
NASA Technical Reports Server (NTRS)
Schneider, R. T.; Kurzweg, U. H.; Cox, J. D.; Weinstein, N. H.
1983-01-01
A solar pumped liquid laser that can be scaled up to high power (10Mw CW) for space applications was developed. Liquid lasers have the inherent advantage over gases in that they provide much higher lasant densities and thus high power densities. Liquids also have inherent advantages over solids in that they have much higher damage thresholds and are much cheaper to produce for large scale applications. Among the liquid laser media that are potential candidates for solar pumping, the POC13:Nd(3+):ZrC14 liquid was chosen for its high intrinsic efficiency as well as its relatively good stability against decomposition due to protic contamination. The development and testing of the laser liquid and the development of a large solar concentrator to pump the laser was emphasized. The procedure to manufacture the laser liquid must include diagnostic tests of the solvent purity (from protic contamination) at various stages in the production process.
Otero, David; Alho, Ana M; Nijsse, Rolf; Roelfsema, Jeroen; Overgaauw, Paul; Madeira de Carvalho, Luís
Toxocarosis is a zoonotic parasitic disease transmitted from companion animals to humans. Environmental contamination with Toxocara eggs is considered to be the main source of human infections. In Portugal, knowledge regarding the current situation, including density, distribution and environmental contamination by Toxocara spp., is largely unknown. The present study investigated environmental contamination with Toxocara spp. eggs, in soil and faecal samples collected from public parks and playground sandpits in Greater Lisbon, Portugal. A total of 151 soil samples and 135 canine faecal samples were collected from 7 public sandpits and 12 public parks, over a 4 month-period. Soil samples were tested by a modified centrifugation and sedimentation/flotation technique and faecal samples were tested by an adaptation of the Cornell-Wisconsin method. Molecular analysis and sequencing were performed to discriminate Toxocara species in the soil. Overall, 85.7% of the sandpits (6/7) and 50.0% of the parks (6/12) were contaminated with Toxocara spp. eggs. The molecular analysis of soil samples showed that, 85.5% of the sandpits and 34.4% of the parks were contaminated with Toxocara cati eggs. Faecal analysis showed that 12.5% of the sandpits and 3.9% of the parks contained Toxocara canis eggs. In total, 53.0% of soil and 5.9% of faecal samples were positive for Toxocara spp. Additionally, 56.0% of the eggs recovered from the samples were embryonated after 60 days of incubation, therefore considered viable and infective. The average density was 4.2 eggs per hundred grams of soil. Public parks and playground sandpits in the Lisbon area were found to be heavily contaminated with T. cati eggs, representing a serious menace to public health as the studied areas represent common places where people of all ages, particularly children, recreate. This study sounds an alarm bell regarding the necessity to undertake effective measures such as reduction of stray animals, active faecal collection by pet owners, awareness campaigns and control strategies to decrease the high risk to both animal and human health. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Girou, Emmanuelle; Chevaliez, Stéphane; Challine, Dominique; Thiessart, Michaël; Morice, Yoann; Lesprit, Philippe; Tkoub-Scheirlinck, Latifa; Soing-Altrach, Sophan; Cizeau, Florence; Cavin, Celine; André, Martine; Dahmanne, Djamel; Lang, Philippe; Pawlotsky, Jean-Michel
2008-09-01
Nosocomial transmission is the second most frequent cause of hepatitis C virus (HCV) infection. A prospective observational study was conducted to assess the roles of environmental contamination and noncompliance with standard precautions in HCV cross-transmission in a hemodialysis unit. Patients undergoing chronic hemodialysis in a French university hospital unit were systematically screened, revealing 2 sporadic cases of HCV transmission. An investigation was launched to determine whether the patients were infected in the hemodialysis unit and the possible roles of environmental contamination and noncompliance with standard precautions. We examined possible relationships among new cases of HCV infection, environmental contamination by blood and HCV RNA, and compliance with guidelines on hand hygiene and glove use. Two patients experienced seroconversion to HCV during the study period. Phylogenetic analyses showed that 1 of these patients was infected with the same strain as that affecting a chronically infected patient also treated in the unit. Of 740 environmental surface samples, 82 (11%) contained hemoglobin; 6 (7%) of those contained HCV RNA. The rate of compliance with hand hygiene was 37% (95% confidence interval, 35%-39%), and gloves were immediately removed after patient care in 33% (95% confidence interval, 29%-37%) of cases. A low ratio of nurses to patients and poor hand hygiene were independent predictors of the presence of hemoglobin on environmental surfaces. Blood-contaminated surfaces may be a source of HCV cross-transmission in a hemodialysis unit. Strict compliance with hand hygiene and glove use and strict organization of care procedures are needed to reduce the risk of HCV cross-transmission among patients undergoing hemodialysis.
Lee, Cheonghoon; Agidi, Senyo; Marion, Jason W; Lee, Jiyoung
2012-08-01
The genus Arcobacter has been associated with human illness and fecal contamination by humans and animals. To better characterize the health risk posed by this emerging waterborne pathogen, we investigated the occurrence of Arcobacter spp. in Lake Erie beach waters. During the summer of 2010, water samples were collected 35 times from the Euclid, Villa Angela, and Headlands (East and West) beaches, located along Ohio's Lake Erie coast. After sample concentration, Arcobacter was quantified by real-time PCR targeting the Arcobacter 23S rRNA gene. Other fecal genetic markers (Bacteroides 16S rRNA gene [HuBac], Escherichia coli uidA gene, Enterococcus 23S rRNA gene, and tetracycline resistance genes) were also assessed. Arcobacter was detected frequently at all beaches, and both the occurrence and densities of Arcobacter spp. were higher at the Euclid and Villa Angela beaches (with higher levels of fecal contamination) than at the East and West Headlands beaches. The Arcobacter density in Lake Erie beach water was significantly correlated with the human-specific fecal marker HuBac according to Spearman's correlation analysis (r = 0.592; P < 0.001). Phylogenetic analysis demonstrated that most of the identified Arcobacter sequences were closely related to Arcobacter cryaerophilus, which is known to cause gastrointestinal diseases in humans. Since human-pathogenic Arcobacter spp. are linked to human-associated fecal sources, it is important to identify and manage the human-associated contamination sources for the prevention of Arcobacter-associated public health risks at Lake Erie beaches.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-08-01
This document is a site-specific standard request for underground storage tanks located at the Rust Garage Facility. These standards are justified based on conclusion derived from the exposure assessment that indicates there is no current or forseeable future human health risk associated with petroleum contaminants on the site, that current and future ecological risks would be generally limited to subsurface species and plant life with roots extending into the area, and that most of the impacted area at the site is covered by asphalt or concrete. The vertical and horizontal extent of soil and ground water contamination are limited tomore » immediate area of the Rust Garage Facility.« less
A modular approach for automated sample preparation and chemical analysis
NASA Technical Reports Server (NTRS)
Clark, Michael L.; Turner, Terry D.; Klingler, Kerry M.; Pacetti, Randolph
1994-01-01
Changes in international relations, especially within the past several years, have dramatically affected the programmatic thrusts of the U.S. Department of Energy (DOE). The DOE now is addressing the environmental cleanup required as a result of 50 years of nuclear arms research and production. One major obstacle in the remediation of these areas is the chemical determination of potentially contaminated material using currently acceptable practices. Process bottlenecks and exposure to hazardous conditions pose problems for the DOE. One proposed solution is the application of modular automated chemistry using Standard Laboratory Modules (SLM) to perform Standard Analysis Methods (SAM). The Contaminant Analysis Automation (CAA) Program has developed standards and prototype equipment that will accelerate the development of modular chemistry technology and is transferring this technology to private industry.
Current Status of Mycotoxin Contamination of Food Commodities in Zimbabwe.
Nleya, Nancy; Adetunji, Modupeade Christianah; Mwanza, Mulunda
2018-05-03
Agricultural products, especially cereal grains, serve as staple foods in sub-Saharan Africa. However, climatic conditions in this region can lead to contamination of these commodities by moulds, with subsequent production of mycotoxins posing health risks to both humans and animals. There is limited documentation on the occurrence of mycotoxins in sub-Saharan African countries, leading to the exposure of their populations to a wide variety of mycotoxins through consumption of contaminated foods. This review aims at highlighting the current status of mycotoxin contamination of food products in Zimbabwe and recommended strategies of reducing this problem. Zimbabwe is one of the African countries with very little information with regards to mycotoxin contamination of its food commodities, both on the market and at household levels. Even though evidence of multitoxin occurrence in some food commodities such as maize and other staple foods exist, available published research focuses only on Aspergillus and Fusarium mycotoxins, namely aflatoxins, deoxynivalenol (DON), trichothecenes, fumonisins, and zearalenone (ZEA). Occurrence of mycotoxins in the food chain has been mainly associated with poor agricultural practices. Analysis of mycotoxins has been done mainly using chromatographic and immunological methods. Zimbabwe has adopted European standards, but the legislation is quite flexible, with testing for mycotoxin contamination in food commodities being done voluntarily or upon request. Therefore, the country needs to tighten its legislation as well as adopt stricter standards that will improve the food safety and security of the masses.
Microbial contamination of mobile phones in a health care setting in Alexandria, Egypt.
Selim, Heba Sayed; Abaza, Amani Farouk
2015-01-01
This study aimed at investigating the microbial contamination of mobile phones in a hospital setting. Swab samples were collected from 40 mobile phones of patients and health care workers at the Alexandria University Students' Hospital. They were tested for their bacterial contamination at the microbiology laboratory of the High Institute of Public Health. Quantification of bacteria was performed using both surface spread and pour plate methods. Isolated bacterial agents were identified using standard microbiological methods. Methicillin-resistant Staphylococcus aureus was identified by disk diffusion method described by Bauer and Kirby. Isolated Gram-negative bacilli were tested for being extended spectrum beta lactamase producers using the double disk diffusion method according to the Clinical and Laboratory Standards Institute recommendations. All of the tested mobile phones (100%) were contaminated with either single or mixed bacterial agents. The most prevalent bacterial contaminants were methicillin-resistant S. aureus and coagulase-negative staphylococci representing 53% and 50%, respectively. The mean bacterial count was 357 CFU/ml, while the median was 13 CFU/ml using the pour plate method. The corresponding figures were 2,192 and 1,720 organisms/phone using the surface spread method. Mobile phones usage in hospital settings poses a risk of transmission of a variety of bacterial agents including multidrug-resistant pathogens as methicillin-resistant S. aureus. The surface spread method is an easy and useful tool for detection and estimation of bacterial contamination of mobile phones.
Microbial contamination of mobile phones in a health care setting in Alexandria, Egypt
Selim, Heba Sayed; Abaza, Amani Farouk
2015-01-01
Aim: This study aimed at investigating the microbial contamination of mobile phones in a hospital setting. Methods: Swab samples were collected from 40 mobile phones of patients and health care workers at the Alexandria University Students’ Hospital. They were tested for their bacterial contamination at the microbiology laboratory of the High Institute of Public Health. Quantification of bacteria was performed using both surface spread and pour plate methods. Isolated bacterial agents were identified using standard microbiological methods. Methicillin-resistant Staphylococcus aureus was identified by disk diffusion method described by Bauer and Kirby. Isolated Gram-negative bacilli were tested for being extended spectrum beta lactamase producers using the double disk diffusion method according to the Clinical and Laboratory Standards Institute recommendations. Results: All of the tested mobile phones (100%) were contaminated with either single or mixed bacterial agents. The most prevalent bacterial contaminants were methicillin-resistant S. aureus and coagulase-negative staphylococci representing 53% and 50%, respectively. The mean bacterial count was 357 CFU/ml, while the median was 13 CFU/ml using the pour plate method. The corresponding figures were 2,192 and 1,720 organisms/phone using the surface spread method. Conclusions: Mobile phones usage in hospital settings poses a risk of transmission of a variety of bacterial agents including multidrug-resistant pathogens as methicillin-resistant S. aureus. The surface spread method is an easy and useful tool for detection and estimation of bacterial contamination of mobile phones. PMID:25699226
Rostami, Ali; Ebrahimi, Maryam; Mehravar, Saeed; Fallah Omrani, Vahid; Fallahi, Shirzad; Behniafar, Hamed
2016-05-16
Soil-transmitted helminth (STH) infections are responsible for significant burden of morbidity and mortality worldwide. Consumption of raw vegetables without proper washing is one of the major routes of such infections. We evaluate the prevalence of STH contamination in commonly used vegetables in Mazandaran province, northern Iran. A total of 772 fresh raw vegetables were obtained from retail markets. Each sample was divided into two groups. One group was used as the unwashed sample and the second group was washed with standard washing procedures. Then, samples were examined for helminth eggs by using standard methods. Data analysis was performed using SPSS20. The overall prevalence of STHs was 14.89% (115/772). The rate of STH contamination was significantly higher in warm seasons (20.5%, 79/386) than in cold seasons (9.32%, 36/386) among the unwashed vegetables (OR=2.50; CI 95%=1.64-3.8; P<0.001). No parasites were observed in standard washed samples (OR=271.40; CI 95%=16.84-4373.64; P<0.001). Prevalence of STH contamination was significantly higher in leafy vegetables than root vegetables (OR=1.67; CI 95%=1.09-2.55; P<0.05). The prevalence of STHs species in all the vegetables were as follows: Ascaris lumbricoides (3.36%), Trichuris trichiura (2.2%), hookworms (2.9%), Toxocara spp. (1.68%), Trichostrongylus spp. (1.55), Taenia sp. (0.9%) and Hymenolepis nana (2.2%). The results of the present study emphasized that vegetables are potential risk factor for transmission of helminth infection to human in northern Iran. It is necessary that health authorities trained the consumers to proper and standard washing of vegetables before consumption. Copyright © 2016 Elsevier B.V. All rights reserved.
Kocovsky, Patrick M.; Rudstam, Lars G.; Yule, Daniel L.; Warner, David M.; Schaner, Ted; Pientka, Bernie; Deller, John W.; Waterfield, Holly A.; Witzel, Larry D.; Sullivan, Patrick J.
2013-01-01
Standardized methods of data collection and analysis ensure quality and facilitate comparisons among systems. We evaluated the importance of three recommendations from the Standard Operating Procedure for hydroacoustics in the Laurentian Great Lakes (GLSOP) on density estimates of target species: noise subtraction; setting volume backscattering strength (Sv) thresholds from user-defined minimum target strength (TS) of interest (TS-based Sv threshold); and calculations of an index for multiple targets (Nv index) to identify and remove biased TS values. Eliminating noise had the predictable effect of decreasing density estimates in most lakes. Using the TS-based Sv threshold decreased fish densities in the middle and lower layers in the deepest lakes with abundant invertebrates (e.g., Mysis diluviana). Correcting for biased in situ TS increased measured density up to 86% in the shallower lakes, which had the highest fish densities. The current recommendations by the GLSOP significantly influence acoustic density estimates, but the degree of importance is lake dependent. Applying GLSOP recommendations, whether in the Laurentian Great Lakes or elsewhere, will improve our ability to compare results among lakes. We recommend further development of standards, including minimum TS and analytical cell size, for reducing the effect of biased in situ TS on density estimates.
Development of standards associated with assessing the bioavailability of contaminants in sediment will be used as a case study for how standards have been developed through Committee E47. In 1987, Committee E47 established Subcommittee E47.03 on Sediment Assessment and Toxicity....
NASA Technical Reports Server (NTRS)
1984-01-01
In order to define ribonuclease contamination, an assay for ribonuclease having picogram level sensitivity was established. In this assay, polycytidylic acid is digested by ribonuclease leading to smaller fragments of poly C that remain soluble after treatment of the sample with perchloric acid and lanthanum acetate. An absorbance measurement at 260 nm of the supernatant from the centrifuged sample measures the ribonuclease. A standard curve is shown. Using this assay procedure, ribonuclease contamination was found to be significant in routine laboratory proteins, in particular, bovine serum albumin, lysozyme, catalase, and cytochrome C. This was confirmed by demonstrating a considerable reduction in this activity in the presence of phosphate buffer since phosphate inhibits ribonuclease. Ribonuclease contamination was not significantly encountered in routine laboratory glassware, plasticware, column surfaces, chromatographic particles, and buffer reagents, including airborne contamination. Some contamination could be introduced by fingerprints, however.
Contamination detection NDE for cleaning process inspection
NASA Technical Reports Server (NTRS)
Marinelli, W. J.; Dicristina, V.; Sonnenfroh, D.; Blair, D.
1995-01-01
In the joining of multilayer materials, and in welding, the cleanliness of the joining surface may play a large role in the quality of the resulting bond. No non-intrusive techniques are currently available for the rapid measurement of contamination on large or irregularly shaped structures prior to the joining process. An innovative technique for the measurement of contaminant levels in these structures using laser based imaging is presented. The approach uses an ultraviolet excimer laser to illuminate large and/or irregular surface areas. The UV light induces fluorescence and is scattered from the contaminants. The illuminated area is viewed by an image-intensified CCD (charge coupled device) camera interfaced to a PC-based computer. The camera measures the fluorescence and/or scattering from the contaminants for comparison with established standards. Single shot measurements of contamination levels are possible. Hence, the technique may be used for on-line NDE testing during manufacturing processes.
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
NASA Technical Reports Server (NTRS)
Seasly, Elaine
2015-01-01
To combat contamination of physical assets and provide reliable data to decision makers in the space and missile defense community, a modular open system architecture for creation of contamination models and standards is proposed. Predictive tools for quantifying the effects of contamination can be calibrated from NASA data of long-term orbiting assets. This data can then be extrapolated to missile defense predictive models. By utilizing a modular open system architecture, sensitive data can be de-coupled and protected while benefitting from open source data of calibrated models. This system architecture will include modules that will allow the designer to trade the effects of baseline performance against the lifecycle degradation due to contamination while modeling the lifecycle costs of alternative designs. In this way, each member of the supply chain becomes an informed and active participant in managing contamination risk early in the system lifecycle.
Weese, J Scott; Rousseau, J.
2006-01-01
There are concerns regarding the safety of feeding raw meat to household pets. This study demonstrated that Salmonella persists in food bowls that are inoculated with Salmonella-containing raw meat. Standard methods of cleaning and disinfection were minimally effective at eliminating Salmonella contamination. PMID:17017654
Method and apparatus for removal of gaseous, liquid and particulate contaminants from molten metals
Hobson, D.O.; Alexeff, I.; Sikka, V.K.
1987-08-10
Method and apparatus for removal of nonelectrically-conducting gaseous, liquid, and particulate contaminants from molten metal compositions by applying a force thereto. The force (commonly referred to as the Lorentz Force) exerted by simultaneous application of an electric field and a magnetic field on a molten conductor causes an increase, in the same direction as the force, in the apparent specific gravity thereof, but does not affect the nonconducting materials. This difference in apparent densities cause the nonconducting materials to ''float'' in the opposite direction from the Lorentz Force at a rapid rate. Means are further provided for removal of the contaminants and prevention of stirring due to rotational forces generated by the applied fields. 6 figs.
Method and apparatus for removal of gaseous, liquid and particulate contaminants from molten metals
Hobson, David O.; Alexeff, Igor; Sikka, Vinod K.
1988-01-01
Method and apparatus for removal of nonelectrically-conducting gaseous, liquid, and particulate contaminants from molten metal compositions by applying a force thereto. The force (commonly referred to as the Lorentz Force) exerted by simultaneous application of an electric field and a magnetic field on a molten conductor causes an increase, in the same direction as the force, in the apparent specific gravity thereof, but does not affect the nonconducting materials. This difference in apparent densities cause the nonconducting materials to "float" in the opposite direction from the Lorentz Force at a rapid rate. Means are further provided for removal of the contaminants and prevention of stirring due to rotational forces generated by the applied fields.
Ghasemian, Saloumeh; Asadishad, Bahareh; Omanovic, Sasha; Tufenkji, Nathalie
2017-12-01
Electrochemical disinfection has been shown to be an efficient method with a shortrequired contact time for treatment of drinking water supplies, industrial raw water supplies, liquid foodstuffs, and wastewater effluents. In the present work, the electrochemical disinfection of saline water contaminated with bacteria was investigated in chloride-containing solutions using Sb-doped Sn 80% -W 20% -oxide anodes. The influence of current density, bacterial load, initial chloride concentration, solution pH, and the type of bacteria (E. coli D21, E. coli O157:H7, and E. faecalis) on disinfection efficacy was systematically examined. The impact of natural organic matter and a radical scavenger on the disinfection process was also examined. The electrochemical system was highly effective in bacterial inactivation for a 0.1 M NaCl solution contaminated with ∼10 7 CFU/mL bacteria by applying a current density ≥1 mA/cm 2 through the cell.100% inactivation of E. coli D21 was achieved with a contact time of less than 60 s and power consumption of 48 Wh/m 3 , by applying a current density of 6 mA/cm 2 in a 0.1 M NaCl solution contaminated with ∼10 7 CFU/mL. Reactive chlorine species as well as reactive oxygen species (e.g. hydroxyl radicals) generated in situ during the electrochemical process were determined to be responsible for inactivation of bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.
Afonso, Eve; Lemoine, Mélissa; Poulle, Marie-Lazarine; Ravat, Marie-Caroline; Romand, Stéphane; Thulliez, Philippe; Villena, Isabelle; Aubert, Dominique; Rabilloud, Muriel; Riche, Benjamin; Gilot-Fromont, Emmanuelle
2008-07-01
In urban areas, there may be a high local risk of zoonosis due to high densities of stray cat populations. In this study, soil contamination by oocysts of Toxoplasma gondii was searched for, and its spatial distribution was analysed in relation to defecation behaviour of cats living in a high-density population present in one area of Lyon (France). Sixteen defecation sites were first identified. Cats were then repeatedly fed with marked food and the marked faeces were searched for in the defecation sites. Of 260 markers, 72 were recovered from 24 different cats. Defecation sites were frequented by up to 15 individuals. Soil samples were also examined in order to detect the presence of T. gondii using real-time PCR. The entire study area was then sampled according to cat density and vegetation cover type. Only three of 55 samples were positive and all came from defecation sites. In a second series of observations, 16 defecation sites were sampled. Eight of 62 samples tested positive, originating in five defecation sites. Laboratory experiments using experimental seeding of soil showed that the inoculated dose that can be detected in 50% of assays equals 100-1000oocysts/g, depending on the strain. This study shows that high concentrations of oocysts can be detected in soil samples using molecular methods and suggests that spatial distribution of contamination areas is highly heterogeneous. Positive samples were only found in some of the defecation sites, signifying that at-risk points for human and animal infection may be very localised.
40 CFR 192.10 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for Cleanup of Land and Buildings Contaminated with Residual Radioactive Materials from Inactive Uranium Processing... radioactive materials at which all or substantially all of the uranium was produced for sale to any Federal...
40 CFR 192.10 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND ENVIRONMENTAL PROTECTION STANDARDS FOR URANIUM AND THORIUM MILL TAILINGS Standards for Cleanup of Land and Buildings Contaminated with Residual Radioactive Materials from Inactive Uranium Processing... radioactive materials at which all or substantially all of the uranium was produced for sale to any Federal...
Rapid totally diverting loop sigmoid colostomy with noncontaminating rectal irrigation.
Sachatello, C R; Maull, K I
1977-08-01
Loop sigmoid colostomy employing a stapling device and catheter irrigation of the distal segment is less time-consuming and has lest potential for contamination than the standard double-barrel colostomy. Unlike the standard loop colostomy, it is totally diverting.
78 FR 37505 - International Standard-Setting Activities
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... Code of Practice for Weed Control to Prevent and Reduce Pyrrolizidine Alkaloid Contamination in Food... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2013-0002] International Standard-Setting Activities AGENCY: Office of Food Safety, USDA. ACTION: Notice. SUMMARY: This...
Morioka, Noriko; Tomio, Jun; Seto, Toshikazu; Kobayashi, Yasuki
2017-01-01
In Japan, the revision of the fee schedules in 2006 introduced a new category of general care ward for more advanced care, with a higher staffing standard, a patient-to-nurse ratio of 7:1. Previous studies have suggested that these changes worsened inequalities in the geographic distribution of nurses, but there have been few quantitative studies evaluating this effect. This study aimed to investigate the association between the distribution of 7:1 beds and the geographic distribution of hospital nursing staffs. We conducted a secondary data analysis of hospital reimbursement reports in 2012 in Japan. The study units were secondary medical areas (SMAs) in Japan, which are roughly comparable to hospital service areas in the United States. The outcome variable was the nurse density per 100,000 population in each SMA. The 7:1 bed density per 100,000 population was the main independent variable. To investigate the association between the nurse density and 7:1 bed density, adjusting for other variables, we applied a multiple linear regression model, with nurse density as an outcome variable, and the bed densities by functional category of inpatient ward as independent variables, adding other variables related to socio-economic status and nurse workforce. To investigate whether 7:1 bed density made the largest contribution to the nurse density, compared to other bed densities, we estimated the standardized regression coefficients. There were 344 SMAs in the study period, of which 343 were used because of data availability. There were approximately 553,600 full time equivalent nurses working in inpatient wards in hospitals. The mean (standard deviation) of the full time equivalent nurse density was 426.4 (147.5) and for 7:1 bed density, the figures were 271.9 (185.9). The 7:1 bed density ranged from 0.0 to 1,295.5. After adjusting for the possible confounders, there were more hospital nurses in the areas with higher densities of 7:1 beds (standardized regression coefficient 0.62, 95% confidence interval 0.56-0.68). We found that the 7:1 nurse staffing standard made the largest contribution to the geographic distribution of hospital nurses, adjusted for socio-economic status and nurse workforce-related factors.
NASA Astrophysics Data System (ADS)
Gorelick, Steven M.; Voss, Clifford I.; Gill, Philip E.; Murray, Walter; Saunders, Michael A.; Wright, Margaret H.
1984-04-01
A simulation-management methodology is demonstrated for the rehabilitation of aquifers that have been subjected to chemical contamination. Finite element groundwater flow and contaminant transport simulation are combined with nonlinear optimization. The model is capable of determining well locations plus pumping and injection rates for groundwater quality control. Examples demonstrate linear or nonlinear objective functions subject to linear and nonlinear simulation and water management constraints. Restrictions can be placed on hydraulic heads, stresses, and gradients, in addition to contaminant concentrations and fluxes. These restrictions can be distributed over space and time. Three design strategies are demonstrated for an aquifer that is polluted by a constant contaminant source: they are pumping for contaminant removal, water injection for in-ground dilution, and a pumping, treatment, and injection cycle. A transient model designs either contaminant plume interception or in-ground dilution so that water quality standards are met. The method is not limited to these cases. It is generally applicable to the optimization of many types of distributed parameter systems.
Pacheco, Mário; Santos, Maria Ana
2002-11-01
A prolonged toxicity study was carried out in young European eel (Anguilla anguilla L.) to evaluate the effects of environmental contaminants, namely, two individual standard compounds, benzo[a]pyrene (BaP) and dehydroabietic acid (DHAA), and a complex mixture, bleached kraft pulp mill effluent (BKPME). Fish were exposed to BaP (0.22, 0.45, and 0.9 microM) and BKPME (3.12%, 6.25%, and 12.5% (v/v)) for 3, 7, and 30 days and to DHAA (0.07, 0.15, and 0.30 microM) for 3, 7, 30, 90, and 180 days. The biomarkers include biotransformation and genotoxicity indicators, such as total ethoxyresorufin O-deethylase (EROD) activity and frequency of erythrocytic nuclear abnormalities (ENAs), respectively. Hematological dynamics was assessed as frequency of immature erythrocytes (IEs). Histopathological examinations were carried out for the highest concentrations and for 30 days and longer exposures. Total EROD increases significantly only after 180 days of DHAA exposure. However, significant ENA induction was generally observed during exposure to all contaminants tested. Nevertheless, some of the ENA results suggest an altered genotoxic response, which may arise either from short-term exposures to the highest contaminant levels or long-term exposures to the lowest contaminant levels. IE frequency decreased significantly after 30 days of exposure to 0.45 microM BaP and 180 days of exposure to the entire DHAA concentration range. Increased density of pigmented macrophage aggregates in 30-day BaP- and BKPME-exposed fish as well as in 90- and 180-day DHAA-exposed fish confirmed histopathological liver alterations. Bile accumulation in hepatocytes after BaP treatment, cytoplasmic vacuolization and cell atrophy following DHAA exposure, as well as liver loss of parenchymal cells in BKPME-exposed fish, were also detected. Dispersed necrosis and focal inflammation were observed in the livers of all treated groups. Fish exposed to DHAA and BKPME showed skin and gill disruption as well as kidney Malpighian corpuscle alterations. All 30-day-treated groups revealed intense spleen hemosiderosis, indicating increased erythrophagia. This splenic effect may be strongly correlated with the observed disappearance of ENAs. Neoplastic lesions were not found. A multibiomarker strategy, which includes EROD, ENA, and IE assays as well as histopathological studies, contributed to a better understanding of the global toxic process.
NASA Astrophysics Data System (ADS)
Giblin, Jay P.; Dixon, John; Dupuis, Julia R.; Cosofret, Bogdan R.; Marinelli, William J.
2017-05-01
Sensor technologies capable of detecting low vapor pressure liquid surface contaminants, as well as solids, in a noncontact fashion while on-the-move continues to be an important need for the U.S. Army. In this paper, we discuss the development of a long-wave infrared (LWIR, 8-10.5 μm) spatial heterodyne spectrometer coupled with an LWIR illuminator and an automated detection algorithm for detection of surface contaminants from a moving vehicle. The system is designed to detect surface contaminants by repetitively collecting LWIR reflectance spectra of the ground. Detection and identification of surface contaminants is based on spectral correlation of the measured LWIR ground reflectance spectra with high fidelity library spectra and the system's cumulative binary detection response from the sampled ground. We present the concepts of the detection algorithm through a discussion of the system signal model. In addition, we present reflectance spectra of surfaces contaminated with a liquid CWA simulant, triethyl phosphate (TEP), and a solid simulant, acetaminophen acquired while the sensor was stationary and on-the-move. Surfaces included CARC painted steel, asphalt, concrete, and sand. The data collected was analyzed to determine the probability of detecting 800 μm diameter contaminant particles at a 0.5 g/m2 areal density with the SHSCAD traversing a surface.
Kaur, Jasmeen; Adamchuk, Viacheslav I.; Whalen, Joann K.; Ismail, Ashraf A.
2015-01-01
The eco-toxicological indicators used to evaluate soil quality complement the physico-chemical criteria employed in contaminated site remediation, but their cost, time, sophisticated analytical methods and in-situ inapplicability pose a major challenge to rapidly detect and map the extent of soil contamination. This paper describes a sensor-based approach for measuring potential (substrate-induced) microbial respiration in diesel-contaminated and non-contaminated soil and hence, indirectly evaluates their microbial activity. A simple CO2 sensing system was developed using an inexpensive non-dispersive infrared (NDIR) CO2 sensor and was successfully deployed to differentiate the control and diesel-contaminated soils in terms of CO2 emission after glucose addition. Also, the sensor system distinguished glucose-induced CO2 emission from sterile and control soil samples (p ≤ 0.0001). Significant effects of diesel contamination (p ≤ 0.0001) and soil type (p ≤ 0.0001) on glucose-induced CO2 emission were also found. The developed sensing system can provide in-situ evaluation of soil microbial activity, an indicator of soil quality. The system can be a promising tool for the initial screening of contaminated environmental sites to create high spatial density maps at a relatively low cost. PMID:25730479
On the occurrence of aflatoxin M1 in milk and dairy products.
Prandini, A; Tansini, G; Sigolo, S; Filippi, L; Laporta, M; Piva, G
2009-05-01
Aflatoxins are toxic fungal metabolites found in foods and feeds. When ruminants eat AFB(1)-feedstuffs, they metabolise the toxin and excrete AFM(1) in milk. To control AFM(1) in foods it is necessary to reduce AFB(1) contamination of feeds for dairy cattle by preventing fungal growth and AFB(1) formation in agricultural commodities intended for animal use. Corn and corn-based products are one of the most contaminated feedstuffs; therefore risk factor analysis of AFB(1) contamination in corn is necessary to evaluate risk of AFM(1) contamination in milk and milk products. During the corn silage production, the aflatoxins production is mostly influenced by: harvest time; fertilization; irrigation; pest control; silage moisture; and storage practices. Due to the lower moisture at harvest and to the conservation methods, the corn grain is mostly exposed to the contamination by Aspergillus species. Therefore, it is necessary to reduce the probability of this contaminant through choice of: hybrids; seeding time and density; suitable ploughing and fertirrigation; and chemical or biological control. Grains harvested with the lowest possible moisture and conservation moisture close to or less than 14% are necessary to reduce contamination risks, as is maintaining mass to homogeneous moisture. Kernel mechanical damage, grain cleaning practices and conservation temperature are also factors which need to be carefully controlled.
Ferrando, Agustina; Gonzalez, Emilia; Franco, Marcos; Commendatore, Marta; Nievas, Marina; Militon, Cécile; Stora, Georges; Gilbert, Franck; Esteves, José Luis; Cuny, Philippe
2015-10-01
The Patagonian coast is characterized by the existence of pristine ecosystems which may be particularly sensitive to oil contamination. In this study, a simulated oil spill at acute and chronic input levels was carried out to assess the effects of contamination on the macrobenthic community structure and the bioturbation activity of sediments sampled in Caleta Valdés creek. Superficial sediments were either noncontaminated or contaminated by Escalante crude oil and incubated in the laboratory for 30 days. Oil contamination induced adverse effects on macrobenthic community at both concentrations with, for the highest concentration, a marked decrease of approximately 40 and 55 % of density and specific richness, respectively. Besides the disappearance of sensitive species, some other species like Oligochaeta sp. 1, Paranebalia sp., and Ostracoda sp. 2 species have a higher resistance to oil contamination. Sediment reworking activity was also affected by oil addition. At the highest level of contamination, nearly no activity was observed due to the high mortality of macroorganisms. The results strongly suggest that an oil spill in this protected marine area with no previous history of contamination would have a deep impact on the non-adapted macrobenthic community.
Steel test panel helps control additives in pyrophosphate copper plating
NASA Technical Reports Server (NTRS)
Hollar, W. T.
1967-01-01
Test panel helps control maximum tolerance level for plating solution contaminants. It provides low, medium, and high-current density areas such as exist in production plating, and plating is examined for uniformity of texture and ductility.
Chalmers, Ann
2002-01-01
Streambed sediment and fish tissue were collected at 14 river sites in eastern New England during low-flow conditions in 1998 and 1999 as part of the New England Coastal Basins (NECB) study of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program. Sampling sites were selected over a range of urban settings. Population densities at selected sites ranged from 26 to 3,585 people per square mile, and urban land use ranged from 1 to 68 percent. The streambed sediment samples were analyzed for a total of 141 contaminants, including 45 trace elements, 32 organochlorine compounds, and 64 semi-volatile organic compounds. The fish tissue samples were analyzed for 22 trace elements and 28 organochlorine compounds. Concentrations of selected contaminants in both streambed sediment and fish tissue correlated more strongly with population density than with other watershed characteristics. Cadmium, copper, lead, mercury, zinc, total polycyclic aromatic hydrocarbons (PAHs), total polychlorinated biphenyls (PCBs), dichloro diphenyl trichloroethane and metabolites (DDTM), and total chlordane in streambed sediment all showed strong positive correlations with population density (rho = 0.71 to 0.85, p value = 0.005 to <0.001). Correlations between population density and selected contaminants in fish tissue were less significant than with streambed sediment (rho = 0.62 to 0.72, p value = 0.03 to 0.008). Organic carbon concentrations were correlated with concentrations of arsenic, selenium, total PAHs, total PCBs, and DDTM in streambed sediment. The relation between concentrations of contaminants in streambed sediment and fish tissue was stronger for organochlorine compounds (rho = 0.75 to 0.55, p = 0.005 to 0.065) than for trace elements (rho = 0.63 to 0.53, p = 0.029 to 0.069). The NECB study area had the highest median concentrations of lead, mercury, total PAHs, total PCBs, and DDTM in streambed sediment and the highest median concentration of PCBs in fish tissue compared to 45 other NAWQA study units across the Nation. Concentrations of many of these constituents in streambed sediment also were frequently above the consensus-based Sediment-Quality Guidelines for the protection of wildlife, suggesting they are a threat to the health of aquatic biota in New England.
Legacy of a Chemical Factory Site: Contaminated Groundwater Impacts Stream Macroinvertebrates.
Rasmussen, Jes J; McKnight, Ursula S; Sonne, Anne Th; Wiberg-Larsen, Peter; Bjerg, Poul L
2016-02-01
Legislative and managing entities of EU member states face a comprehensive task because the chemical and ecological impacts of contaminated sites on surface waters must be assessed. The ecological assessment is further complicated by the low availability or, in some cases, absence of ecotoxicity data for many of the compounds occurring at contaminated sites. We studied the potential impact of a contaminated site, characterised by chlorinated solvents, sulfonamides, and barbiturates, on benthic macroinvertebrates in a receiving stream. Most of these compounds are characterised by low or unknown ecotoxicity, but they are continuously discharged into the stream by way of a long-lasting source generating long-term chronic exposure of the stream biota. Our results show that taxonomical density and diversity of especially sediment dwelling taxa were reduced by >50 % at the sampling sites situated in the primary inflow zone of the contaminated GW. Moreover, macroinvertebrate communities at these sampling sites could be distinguished from those at upstream control sites and sites situated along a downstream dilution gradient using multidimensional scaling. Importantly, macroinvertebrate indices currently used did not identify this impairment, thus underpinning an urgent need for developing suitable tools for the assessment of ecological effects of contaminated sites in streams.
Cosmological Parameter Estimation Using the Genus Amplitude—Application to Mock Galaxy Catalogs
NASA Astrophysics Data System (ADS)
Appleby, Stephen; Park, Changbom; Hong, Sungwook E.; Kim, Juhan
2018-01-01
We study the topology of the matter density field in two-dimensional slices and consider how we can use the amplitude A of the genus for cosmological parameter estimation. Using the latest Horizon Run 4 simulation data, we calculate the genus of the smoothed density field constructed from light cone mock galaxy catalogs. Information can be extracted from the amplitude of the genus by considering both its redshift evolution and magnitude. The constancy of the genus amplitude with redshift can be used as a standard population, from which we derive constraints on the equation of state of dark energy {w}{de}—by measuring A at z∼ 0.1 and z∼ 1, we can place an order {{Δ }}{w}{de}∼ { O }(15 % ) constraint on {w}{de}. By comparing A to its Gaussian expectation value, we can potentially derive an additional stringent constraint on the matter density {{Δ }}{{{Ω }}}{mat}∼ 0.01. We discuss the primary sources of contamination associated with the two measurements—redshift space distortion (RSD) and shot noise. With accurate knowledge of galaxy bias, we can successfully remove the effect of RSD, and the combined effect of shot noise and nonlinear gravitational evolution is suppressed by smoothing over suitably large scales {R}{{G}}≥slant 15 {Mpc}/h. Without knowledge of the bias, we discuss how joint measurements of the two- and three-dimensional genus can be used to constrain the growth factor β =f/b. The method can be applied optimally to redshift slices of a galaxy distribution generated using the drop-off technique.
Elloumi, Fathi; Hu, Zhiyuan; Li, Yan; Parker, Joel S; Gulley, Margaret L; Amos, Keith D; Troester, Melissa A
2011-06-30
Genomic tests are available to predict breast cancer recurrence and to guide clinical decision making. These predictors provide recurrence risk scores along with a measure of uncertainty, usually a confidence interval. The confidence interval conveys random error and not systematic bias. Standard tumor sampling methods make this problematic, as it is common to have a substantial proportion (typically 30-50%) of a tumor sample comprised of histologically benign tissue. This "normal" tissue could represent a source of non-random error or systematic bias in genomic classification. To assess the performance characteristics of genomic classification to systematic error from normal contamination, we collected 55 tumor samples and paired tumor-adjacent normal tissue. Using genomic signatures from the tumor and paired normal, we evaluated how increasing normal contamination altered recurrence risk scores for various genomic predictors. Simulations of normal tissue contamination caused misclassification of tumors in all predictors evaluated, but different breast cancer predictors showed different types of vulnerability to normal tissue bias. While two predictors had unpredictable direction of bias (either higher or lower risk of relapse resulted from normal contamination), one signature showed predictable direction of normal tissue effects. Due to this predictable direction of effect, this signature (the PAM50) was adjusted for normal tissue contamination and these corrections improved sensitivity and negative predictive value. For all three assays quality control standards and/or appropriate bias adjustment strategies can be used to improve assay reliability. Normal tissue sampled concurrently with tumor is an important source of bias in breast genomic predictors. All genomic predictors show some sensitivity to normal tissue contamination and ideal strategies for mitigating this bias vary depending upon the particular genes and computational methods used in the predictor.
Sirsat, Sujata A; Kim, Kawon; Gibson, Kristen E; Crandall, Phillip G; Ricke, Steven C; Neal, Jack A
2014-03-05
Cross contamination of foodborne pathogens in the retail environment is a significant public health issue contributing to an increased risk for foodborne illness. Ready-to-eat (RTE) processed foods such as deli meats, cheese, and in some cases fresh produce, have been involved in foodborne disease outbreaks due to contamination with pathogens such as Listeria monocytogenes. With respect to L. monocytogenes, deli slicers are often the main source of cross contamination. The goal of this study was to use a fluorescent compound to simulate bacterial contamination and track this contamination in a retail setting. A mock deli kitchen was designed to simulate the retail environment. Deli meat was inoculated with the fluorescent compound and volunteers were recruited to complete a set of tasks similar to those expected of a food retail employee. The volunteers were instructed to slice, package, and store the meat in a deli refrigerator. The potential cross contamination was tracked in the mock retail environment by swabbing specific areas and measuring the optical density of the swabbed area with a spectrophotometer. The results indicated that the refrigerator (i.e. deli case) grip and various areas on the slicer had the highest risk for cross contamination. The results of this study may be used to develop more focused training material for retail employees. In addition, similar methodologies could also be used to track microbial contamination in food production environments (e.g. small farms), hospitals, nursing homes, cruise ships, and hotels.
Colling Wipe Samples for VX Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koester, C; Hoppes, W G
2010-02-11
This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.
The long-term problems of contaminated land: Sources, impacts and countermeasures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baes, C.F. III
1986-11-01
This report examines the various sources of radiological land contamination; its extent; its impacts on man, agriculture, and the environment; countermeasures for mitigating exposures; radiological standards; alternatives for achieving land decontamination and cleanup; and possible alternatives for utilizing the land. The major potential sources of extensive long-term land contamination with radionuclides, in order of decreasing extent, are nuclear war, detonation of a single nuclear weapon (e.g., a terrorist act), serious reactor accidents, and nonfission nuclear weapons accidents that disperse the nuclear fuels (termed ''broken arrows'').
Detection of Salmonella sp in chicken cuts using immunomagnetic separation
de Cássia dos Santos da Conceição, Rita; Moreira, Ângela Nunes; Ramos, Roberta Juliano; Goularte, Fabiana Lemos; Carvalhal, José Beiro; Aleixo, José Antonio Guimarães
2008-01-01
The immunomagnetic separation (IMS) is a technique that has been used to increase sensitivity and specificity and to decrease the time required for detection of Salmonella in foods through different methodologies. In this work we report on the development of a method for detection of Salmonella in chicken cuts using in house antibody-sensitized microspheres associated to conventional plating in selective agar (IMS-plating). First, protein A-coated microspheres were sensitized with polyclonal antibodies against lipopolysacharide and flagella from salmonellae and used to standardize a procedure for capturing Salmonella Enteritidis from pure cultures and detection in selective agar. Subsequently, samples of chicken meat experimentally contaminated with S. Enteritidis were analyzed immediately after contamination and after 24h of refrigeration using three enrichment protocols. The detection limit of the IMS-plating procedure after standardization with pure culture was about 2x10 CFU/mL. The protocol using non-selective enrichment for 6-8h, selective enrichment for 16-18h and a post-enrichment for 4h gave the best results of S. Enteritidis detection by IMS-plating in experimentally contaminated meat. IMS-plating using this protocol was compared to the standard culture method for salmonellae detection in naturally contaminated chicken cuts and yielded 100% sensitivity and 94% specificity. The method developed using in house prepared magnetic microespheres for IMS and plating in selective agar was able to diminish by at least one day the time required for detection of Salmonella in chicken products by the conventional culture method. PMID:24031199
Extraction of organic contaminants from marine sediments and tissues using microwave energy.
Jayaraman, S; Pruell, R J; McKinney, R
2001-07-01
In this study, we compared microwave solvent extraction (MSE) to conventional methods for extracting organic contaminants from marine sediments and tissues with high and varying moisture content. The organic contaminants measured were polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). Initial experiments were conducted on dry standard reference materials (SRMs) and field collected marine sediments. Moisture content in samples greatly influenced the recovery of the analytes of interest. When wet sediments were included in a sample batch, low recoveries were often encountered in other samples in the batch, including the dry SRM. Experiments were conducted to test the effect of standardizing the moisture content in all samples in a batch prior to extraction. SRM1941a (marine sediment). SRM1974a (mussel tissue), as well as QA96SED6 (marine sediment), and QA96TIS7 (marine tissue), both from 1996 NIST Intercalibration Exercise were extracted using microwave and conventional methods. Moisture levels were adjusted in SRMs to match those of marine sediment and tissue samples before microwave extraction. The results demonstrated that it is crucial to standardize the moisture content in all samples, including dry reference material to ensure good recovery of organic contaminants. MSE yielded equivalent or superior recoveries compared to conventional methods for the majority of the compounds evaluated. The advantages of MSE over conventional methods are reduced solvent usage, higher sample throughput and the elimination of halogenated solvent usage.
Functional integrity of the interrenal tissue of yellow perch from contaminated sites tested in vivo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girard, C.; Brodeur, J.C.; Hontela, A.
1995-12-31
The normal activation of the hypothalamo-pituitary-interrenal axis (HPI axis) in response to capture is disrupted in fish subjected to life-long exposure to heavy metals, PCBs and PAHs. The ability to increase plasma cortisol in yellow perch (Perca flavescens) from sites contaminated by heavy metals and organic compounds, and from a reference site was assessed by the Capture stress test and by the ACTH Challenge test, a new standardized in vivo method designed for field studies. The effects of seasonal factors, such as temperature and gonadal maturity on these tests were investigated. Measures of liver and muscle glycogen and histopathology weremore » made to further characterize the biochemical and structural changes that may occur along with hormonal changes. The Capture stress test showed that an acute source of stress induced a lower cortisol response in fish from the highly contaminated site compared to the reference site, revealing a functional impairment of the HPI axis. The ACTH Challenge test showed that the hormonal responsiveness of the cortisol-secreting interrenal tissue, stimulated by a standard dose of ACTH injected i.p., was lower in fish from the highly contaminated site than the reference site. Spring is the season during which the impairment was the most evident. The possibility of using the reduced capacity of feral fish to respond to a standardized ACTH Challenge as an early bioindicator of toxic stress is discussed.« less
Wasana, Hewa M S; Perera, Gamage D R K; Gunawardena, Panduka De S; Fernando, Palika S; Bandara, Jayasundera
2017-02-14
Despite WHO standards, waterborne diseases among the human being are rising alarmingly. It is known that the prolong exposure to contaminated water has major impact on public health. The effect of chemical contaminations in drinking water on human being is found to be chronic rather than acute and hence can be defined "consumption of contaminated drinking water could be a silent killer". As the WHO recommended water quality standards are only for individual element and synergic effects of trace metals and anions have not been considered, investigation of synergic effects of trace metals and anions and their effect on human being is of prime important research. By an animal trial, we investigated the synergic effect(s) of heavy metals, aluminium, arsenic, fluoride and hardness in drinking water on kidney tissues of mice. Our investigation strongly suggests existing of a synergic effect especially among Cd, F and hardness of water which could lead to severe kidney damage in mice, even at WHO maximum recommended levels. Hence, the synergic effect(s) of trace metals, fluoride and hardness present in drinking water should be investigated meticulously when stipulating the water quality at WHO maximum recommended levels.
NASA Astrophysics Data System (ADS)
Wasana, Hewa M. S.; Perera, Gamage D. R. K.; Gunawardena, Panduka De S.; Fernando, Palika S.; Bandara, Jayasundera
2017-02-01
Despite WHO standards, waterborne diseases among the human being are rising alarmingly. It is known that the prolong exposure to contaminated water has major impact on public health. The effect of chemical contaminations in drinking water on human being is found to be chronic rather than acute and hence can be defined “consumption of contaminated drinking water could be a silent killer”. As the WHO recommended water quality standards are only for individual element and synergic effects of trace metals and anions have not been considered, investigation of synergic effects of trace metals and anions and their effect on human being is of prime important research. By an animal trial, we investigated the synergic effect(s) of heavy metals, aluminium, arsenic, fluoride and hardness in drinking water on kidney tissues of mice. Our investigation strongly suggests existing of a synergic effect especially among Cd, F and hardness of water which could lead to severe kidney damage in mice, even at WHO maximum recommended levels. Hence, the synergic effect(s) of trace metals, fluoride and hardness present in drinking water should be investigated meticulously when stipulating the water quality at WHO maximum recommended levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-10-01
The purpose of this task is to determine if environmental contamination has resulted from waste disposal practices at Otis ANGB MA; to provide estimates of the magnitude and extent of contamination, should contamination be found; to identify potential environmental consequences of migrating pollutants; to identify any additional investigations and their attendant costs necessary to identify the magnitude, extent and direction of movement of discovered contaminants. Partial contents include: well and test pit logs; site safety plan; laboratory analytical methods and quality assurance; and Federal and state drinking water and human health standards applicable in Massachusetts.
Lateral movement of contaminated ground water from Merrill Field Landfill, Anchorage, Alaska
Brunett, J.O.
1990-01-01
A sanitary landfill used in Anchorage, Alaska, since the 1940 's was closed in 1987. Leachate from the landfill does not appear to be contaminating a small creek flowing through a conduit in the landfill, but leachate is being transported by groundwater into a wetlands to the south. An electromagnetic survey of the unconfined aquifer and subsequent sampling from wells indicate that minor amounts of contaminants have reached much of the wetlands as far as Chester Creek, about 2,200 ft to the south. However, concentrations of these contaminants in the groundwater are generally less than U.S. Environmental Protection Agency standards for drinking water except within the landfill itself. (USGS)
Household effectiveness vs. laboratory efficacy of point-of-use chlorination.
Levy, Karen; Anderson, Larissa; Robb, Katharine A; Cevallos, William; Trueba, Gabriel; Eisenberg, Joseph N S
2014-05-01
Treatment of water at the household level offers a promising approach to combat the global burden of diarrheal diseases. In particular, chlorination of drinking water has been a widely promoted strategy due to persistence of residual chlorine after initial treatment. However, the degree to which chlorination can reduce microbial levels in a controlled setting (efficacy) or in a household setting (effectiveness) can vary as a function of chlorine characteristics, source water characteristics, and household conditions. To gain more understanding of these factors, we carried out an observational study within households in rural communities of northern coastal Ecuador. We found that the efficacy of chlorine treatment under controlled conditions was significantly better than its household effectiveness when evaluated both by ability to meet microbiological safety standards and by log reductions. Water treated with chlorine achieved levels of microbial contamination considered safe for human consumption after 24 h of storage in the household only 39-51% of the time, depending on chlorine treatment regimen. Chlorine treatment would not be considered protective against diarrheal disease according to WHO log reduction standards. Factors that explain the observed compromised effectiveness include: source water turbidity, source water baseline contamination levels, and in-home contamination. Water in 38% of the households that had low turbidity source water (<10 NTU) met the safe water standard as compared with only 17% of the households that had high turbidity source water (>10 NTU). A 10 MPN/100 mL increase in baseline Escherichia coli levels was associated with a 2.2% increase in failure to meet the E. coli standard. Higher mean microbial contamination levels were seen in 54% of household samples in comparison to their matched controls, which is likely the result of in-home contamination during storage. Container characteristics (size of the container mouth) did not influence chlorine effectiveness. We found no significant differences between chlorine treatment regimens in ability to meet the safe water standards or in overall log reductions, although chlorine dosage did modify the effect of source conditions. These results underscore the importance of measuring both source water and household conditions to determine appropriate chlorine levels, as well as to evaluate the appropriateness of chlorine treatment and other point-of-use water quality improvement interventions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Salińska, Aneta; Włostowski, Tadeusz; Zambrzycka, Elżbieta
2012-11-01
Bank voles free living in a contaminated environment are known to be more sensitive to cadmium (Cd) toxicity than the rodents exposed to Cd under laboratory conditions, but the reasons for this difference are poorly defined. The present work was designed to determine whether dietary lead (Pb), a common environmental co-contaminant, and/or animal density that affects various physiological processes, would influence susceptibility to Cd toxicity in the kidneys and liver of these animals. For 6 weeks, the female bank voles were kept individually or in a group of six and provided with diet containing environmentally relevant concentrations of Cd [<0.1 μg/g (control) and 60 μg/g dry wt] and Pb [<0.2 μg/g (control) and 300 μg/g dry wt] alone or in combination. At the end of exposure period, histopathology and analyses of metallothionein, glutathione and zinc that are linked to a protective effect against Cd toxicity, as well as Cd, Pb, copper, iron and lipid peroxidation were carried out. Histopathological changes in the kidneys (a focal glomerular swelling and proximal tubule degeneration) and liver (a focal hepatocyte swelling, vacuolation and inflammation) occurred exclusively in some bank voles kept in a group and exposed to Cd alone (2/6) or Cd + Pb (4/6). The observed toxicity in grouped bank voles appeared not to be based on altered (1) tissue disposition of Cd and/or Pb, (2) metallothionein, glutathione and zinc concentrations, or (3) tissue copper, iron and lipid peroxidation. The data indicate that high population density in combination with environmental Pb may be responsible for an increased susceptibility to Cd toxicity observed in bank voles free living in a contaminated environment; the mechanism by which animal density affects Cd toxicity deserves further study.
Extraction process for removing metallic impurities from alkalide metals
Royer, L.T.
1987-03-20
A development is described for removing metallic impurities from alkali metals by employing an extraction process wherein the metallic impurities are extracted from a molten alkali metal into molten lithium metal due to the immiscibility of the alkali metals in lithium and the miscibility of the metallic contaminants or impurities in the lithium. The purified alkali metal may be readily separated from the contaminant-containing lithium metal by simple decanting due to the differences in densities and melting temperatures of the alkali metals as compared to lithium.
2010-01-01
The epidemiology of MRSA pneumonia varies across countries. One of the most import risk factors for the development of nosocomial MRSA pneumonia is mechanical ventilation. Methicillin resistance in S. aureus ventilator associated pneumonia (VAP) ranged between 37% in German, 54% in the US American and 78% in Asian and Latin American ICUs. In 2009, the incidence density of nosocomial VAP caused by MRSA was 0.28 per 1000 ventilation days in a network of 586 German ICUs. Incidences peaked in neurological and neurosurgical ICUs. Crude hospital mortality in studies performed after 2005 lay between 27% and 59% and attributable MRSA pneumonia mortality at 40%. Since 2005, US American and German data indicate decreasing trends for MRSA pneumonia. Measures to reduce MRSA pneumonia or to control the spread of MRSA include hand hygiene, standard and contact precautions, oral contamination with chlor hexidine, skin decontamination with antiseptics, screening, and (possibly) patient isolation in a single room. PMID:21163726
Biddle, Chuck J; George-Gay, Beverly; Prasanna, Praveen; Hill, Emily M; Davis, Thomas C; Verhulst, Brad
2018-01-01
Anesthesia machines are known reservoirs of bacterial species, potentially contributing to healthcare associated infections (HAIs). An inexpensive, disposable, nonpermeable, transparent anesthesia machine wrap (AMW) may reduce microbial contamination of the anesthesia machine. This study quantified the density and diversity of bacterial species found on anesthesia machines after terminal cleaning and between cases during actual anesthesia care to assess the impact of the AMW. We hypothesized reduced bioburden with the use of the AMW. In a prospective, experimental research design, the AMW was used in 11 surgical cases (intervention group) and not used in 11 control surgical cases. Cases were consecutively assigned to general surgical operating rooms. Seven frequently touched and difficult to disinfect "hot spots" were cultured on each machine preceding and following each case. The density and diversity of cultured colony forming units (CFUs) between the covered and uncovered machines were compared using Wilcoxon signed-rank test and Student's t -tests. There was a statistically significant reduction in CFU density and diversity when the AMW was employed. The protective effect of the AMW during regular anesthetic care provides a reliable and low-cost method to minimize the transmission of pathogens across patients and potentially reduces HAIs.
NATIONAL QA STANDARD FOR ENVIRONMENTAL PROGRAMS FOR HAZARDOUS WASTE MANAGEMENT ACTIVITIES
The clean-up of Federally-owned facilities contaminated by mixtures of hazardous chemical and radioactive wastes involves critical decisions based on environmental data. ederal agencies are currently using several different standards or sets of requirements, including U.S. Enviro...
DEVELOPMENT OF A NATIONAL CONSENSUS STANDARD FOR QUALITY ASSURANCE FOR ENVIRONMENTAL PROGRAMS
Decisions on where and how to clean-up Federally-owned facilities contaminated by mixtures of hazardous chemical and radioactive wastes requires that quality environmental data be obtained. he Federal Government currently using several different standards or sets of requirements ...
Setting Environmental Standards
ERIC Educational Resources Information Center
Fishbein, Gershon
1975-01-01
Recent court decisions have pointed out the complexities involved in setting environmental standards. Environmental health is composed of multiple causative agents, most of which work over long periods of time. This makes the cause-and-effect relationship between health statistics and environmental contaminant exposures difficult to prove in…
NASA Astrophysics Data System (ADS)
Vilbaste, M.; Heinonen, M.; Saks, O.; Leito, I.
2013-08-01
The purpose of this paper is to study the effect of contaminated water in the context of humidity generators. Investigation of different methods to determine the drop in dew-point temperature due to contamination and experiments on actual contamination rates are reported. Different methods for calculating the dew-point temperature effect from electrical conductivity and density measurements are studied with high-purity water and aqueous solutions of NaCl and LiCl. The outcomes of the calculation methods are compared with the results of direct humidity measurements. The results show that the often applied Raoult's law based calculation method is in good agreement with other methods. For studying actual contamination, water samples were kept in glass, plastic, copper and stainless-steel vessels for up to 13 months to investigate natural ionic and organic contamination in vessels with different wall materials. The amount of ionic contamination was found to be higher in copper and glass vessels than in stainless-steel and plastic vessels. The amount of organic contamination was found to be highest in the plastic vessel. In all the cases, however, the corresponding drop in dew-point temperature due to natural contamination was found to be below 0.1 mK. The largest rate of change of dew-point temperature was 26 µK/month. Thus, if proper cleanness is maintained in a humidity generator the effect of contamination of water in the saturator is insignificant compared with the major uncertainty components even in the most accurate generators today.
Tornes, Lan H.
2005-01-01
Data for the Red River of the North (Red River) Basin in Minnesota, North Dakota, and South Dakota were analyzed to determine whether the water quality of streams in the basin is adequate to meet future needs. For the Red River at Emerson, Manitoba, site, pH values, water temperatures, and dissolved-oxygen concentrations generally were within the criteria established for the protection of aquatic life. Dissolved-solids concentrations ranged from 245 to 1,100 milligrams per liter. Maximum sulfate and chloride concentrations were near, but did not exceed, the established secondary maximum contaminant level. The trace elements considered potentially harmful generally were at concentrations that were less than the established guidelines, standards, and criteria. The concentrations of lead that were detected may have occurred as a result of sample contamination. For the Red River upstream from Emerson, Manitoba, sites, pH and other field values rarely exceeded the criteria established for the protection of aquatic life. Many constituent concentrations for the Red River below Fargo, N. site exceeded water-quality guidelines, standards, and criteria. However, the trace-element exceedances could be natural or could be related to pollution or sample contamination. Many of the tributaries in the western part of the Red River Basin had median specific-conductance values that were greater than 1,000 microsiemens per centimeter. Sulfate concentrations occasionally exceeded the established drinking-water standard. Median arsenic concentrations were 6 micrograms per liter or less, and maximum concentrations rarely exceeded the 10-microgram-per-liter drinking-water standard that is scheduled to take effect in 2006. The small concentrations of lead, mercury, and selenium that occasionally were detected may have been a result of sample contamination or other factors. The tributaries in the eastern part of the Red River Basin had median specific-conductance values that were less than 1,000 microsiemens per centimeter. Concentrations of pesticides that were detected and that had regulatory limits were less than the cited water-quality guidelines, standards, and criteria. Concentrations of compounds that were detected generally were less than the sediment- quality standards and criteria. The data considered in this report generally provide a good baseline from which to evaluate changes in water-quality conditions. However, because many of the trace elements detected, including lead and mercury, may have been the result of sample contamination, additional data are needed to confirm that trace-element concentrations generally are low. Concentrations of major ions, including sulfate, and specific conductance may continue to approach drinking-water standards during periods of low flow because the streams, particularly those in the western part of the basin, are sustained mostly by ground-water discharge that generally has large dissolved-solids concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1995-02-01
This risk assessment evaluates the possibility of health and environmental risks from contaminated ground water at the uranium mill tailings site near Durango, Colorado. The former uranium processing site`s contaminated soil and material were removed and placed at a disposal site located in Body Canyon, Colorado, during 1986--1991 by the US Departments of Energy`s Uranium Mill Tailings Remedial Action (UMTRA) Project. Currently, the UMTRA Project is evaluating the nature and extent of ground water contamination at the site. This risk assessment follows an approach similar to that used by the US Environmental Protection Agency. The first step is to determinemore » what site-related contaminants are found in ground water samples. The next step in the risk assessment is to determine how much of these contaminants people might ingest if they got their drinking water from a well on the site. In accordance with standard practice for this type of risk assessment, the highest contaminant concentrations from the most contaminated wells are used. The risk assessment then explains the possible health problems that could result from this amount of contamination.« less
Dynamical Mass Measurements of Contaminated Galaxy Clusters Using Support Distribution Machines
NASA Astrophysics Data System (ADS)
Ntampaka, Michelle; Trac, Hy; Sutherland, Dougal; Fromenteau, Sebastien; Poczos, Barnabas; Schneider, Jeff
2018-01-01
We study dynamical mass measurements of galaxy clusters contaminated by interlopers and show that a modern machine learning (ML) algorithm can predict masses by better than a factor of two compared to a standard scaling relation approach. We create two mock catalogs from Multidark’s publicly available N-body MDPL1 simulation, one with perfect galaxy cluster membership infor- mation and the other where a simple cylindrical cut around the cluster center allows interlopers to contaminate the clusters. In the standard approach, we use a power-law scaling relation to infer cluster mass from galaxy line-of-sight (LOS) velocity dispersion. Assuming perfect membership knowledge, this unrealistic case produces a wide fractional mass error distribution, with a width E=0.87. Interlopers introduce additional scatter, significantly widening the error distribution further (E=2.13). We employ the support distribution machine (SDM) class of algorithms to learn from distributions of data to predict single values. Applied to distributions of galaxy observables such as LOS velocity and projected distance from the cluster center, SDM yields better than a factor-of-two improvement (E=0.67) for the contaminated case. Remarkably, SDM applied to contaminated clusters is better able to recover masses than even the scaling relation approach applied to uncon- taminated clusters. We show that the SDM method more accurately reproduces the cluster mass function, making it a valuable tool for employing cluster observations to evaluate cosmological models.
Kurle, Carolyn M; Bakker, Victoria J; Copeland, Holly; Burnett, Joe; Jones Scherbinski, Jennie; Brandt, Joseph; Finkelstein, Myra E
2016-09-06
The critically endangered California condor (Gymnogyps californianus) has relied intermittently on dead-stranded marine mammals since the Pleistocene, and this food source is considered important for their current recovery. However, contemporary marine mammals contain persistent organic pollutants that could threaten condor health. We used stable carbon and nitrogen isotope, contaminant, and behavioral data in coastal versus noncoastal condors to quantify contaminant transfer from marine mammals and created simulation models to predict the risk of reproductive impairment for condors from exposure to DDE (p,p'-DDE), a major metabolite of the chlorinated pesticide DDT. Coastal condors had higher whole blood isotope values and mean concentrations of contaminants associated with marine mammals, including mercury (whole blood), sum chlorinated pesticides (comprised of ∼95% DDE) (plasma), sum polychlorinated biphenyls (PCBs) (plasma), and sum polybrominated diphenyl ethers (PBDEs) (plasma), 12-100-fold greater than those of noncoastal condors. The mean plasma DDE concentration for coastal condors was 500 ± 670 (standard deviation) (n = 22) versus 24 ± 24 (standard deviation) (n = 8) ng/g of wet weight for noncoastal condors, and simulations predicted ∼40% of breeding-age coastal condors have DDE levels associated with eggshell thinning in other avian species. Our analyses demonstrate potentially harmful levels of marine contaminant transfer to California condors, which could hinder the recovery of this terrestrial species.
Compodock, a new device for sterile docking.
van Der Meer, P F; Biekart, F T; Pietersz, R N; Rebers, S P; Reesink, H W
2000-06-01
A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. Sterility of the connections was assessed by welding tubing with a heavy exterior contamination with Bacillus subtilis spores and also by welding in an environment contaminated with aerosols of B. subtilis. Tubing was either dry or liquid-filled ("wet") and had various diameters. Bacterial culture medium was flushed through the welded area and subsequently cultured. Tensile strength was measured, and, under semi-routine conditions, Compodock was tested for user friendliness and speed. None of the cultures of welded tubing with exterior contamination showed growth, neither the dry-dry (n = 434) nor the wet-wet connections (n = 622). Cultures were also negative for welds made in the contaminated environment (dry-dry, 67; wet-wet, 55). Tensile strength complied fully with ISO 3826 standards (that is, a force of 20 newtons [N] for 15 sec), with a mean maximal strength ranging from 73 to 100 N, depending on diameter and content of the tubing. The semi-routine handling was regarded as good: welds were easily opened; there were clear instructions and error warnings; and the processing time averaged 52 seconds. The Compodock is able to maintain a functionally closed system, with maintenance of sterility, despite heavy exterior bacterial contamination; tensile strength conformed to ISO standards. Compodock is suitable for routine implementation in the blood bank.
Liang, Yaya; Yi, Xiaoyun; Dang, Zhi; Wang, Qin; Luo, Houmei; Tang, Jie
2017-12-12
The purpose of this study was to assess heavy metal contamination and health risks for residents in the vicinity of a tailing pond in Guangdong, southern China. Water, soil, rice, and vegetable samples were collected from the area in the vicinity of the tailing pond. Results showed that surface water was just polluted by Ni and As, while groundwater was not contaminated by heavy metals. The concentrations of Pb, Zn, Cu, Cd, Ni, and As in the paddy soil exceeded the standard values but not those of Cr. In vegetable soils, the concentration of heavy metals was above the standard values except for Ni and As. Soil heavy metal concentrations generally decreased with increasing distance from the polluting source. Leafy vegetables were contaminated by Pb, Cr, Cd, and Ni, while the non-leafy vegetables were contaminated only by Cr. There was a significant difference in heavy metal concentrations between leafy vegetables and non-leafy vegetables. Almost all the rice was polluted by heavy metals. Diet was the most significant contributor to non-carcinogenic risk, which was significantly higher than the safe level of 1. The total cancer risk was also beyond the safe range (10 -6 -10 -4 ). Results revealed that there is a risk of potential health problems to residents in the vicinity of the tailing pond.
Liang, Yaya; Yi, Xiaoyun; Dang, Zhi; Wang, Qin; Luo, Houmei; Tang, Jie
2017-01-01
The purpose of this study was to assess heavy metal contamination and health risks for residents in the vicinity of a tailing pond in Guangdong, southern China. Water, soil, rice, and vegetable samples were collected from the area in the vicinity of the tailing pond. Results showed that surface water was just polluted by Ni and As, while groundwater was not contaminated by heavy metals. The concentrations of Pb, Zn, Cu, Cd, Ni, and As in the paddy soil exceeded the standard values but not those of Cr. In vegetable soils, the concentration of heavy metals was above the standard values except for Ni and As. Soil heavy metal concentrations generally decreased with increasing distance from the polluting source. Leafy vegetables were contaminated by Pb, Cr, Cd, and Ni, while the non-leafy vegetables were contaminated only by Cr. There was a significant difference in heavy metal concentrations between leafy vegetables and non-leafy vegetables. Almost all the rice was polluted by heavy metals. Diet was the most significant contributor to non-carcinogenic risk, which was significantly higher than the safe level of 1. The total cancer risk was also beyond the safe range (10−6–10−4). Results revealed that there is a risk of potential health problems to residents in the vicinity of the tailing pond. PMID:29231884
Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts
Lee, Jung Won; Shin, Hee Bong; Lee, In Kyung
2017-01-01
Objectives To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the χ2-test and Fisher exact test. Results One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (p<0.05). Conclusions Protocols and policies must be reviewed to standardize procedures to clean and disinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced. PMID:28605891
VALIDATION OF STANDARD ANALYTICAL PROTOCOL FOR ...
There is a growing concern with the potential for terrorist use of chemical weapons to cause civilian harm. In the event of an actual or suspected outdoor release of chemically hazardous material in a large area, the extent of contamination must be determined. This requires a system with the ability to prepare and quickly analyze a large number of contaminated samples for the traditional chemical agents, as well as numerous toxic industrial chemicals. Liquid samples (both aqueous and organic), solid samples (e.g., soil), vapor samples (e.g., air) and mixed state samples, all ranging from household items to deceased animals, may require some level of analyses. To meet this challenge, the U.S. Environmental Protection Agency (U.S. EPA) National Homeland Security Research Center, in collaboration with experts from across U.S. EPA and other Federal Agencies, initiated an effort to identify analytical methods for the chemical and biological agents that could be used to respond to a terrorist attack or a homeland security incident. U.S. EPA began development of standard analytical protocols (SAPs) for laboratory identification and measurement of target agents in case of a contamination threat. These methods will be used to help assist in the identification of existing contamination, the effectiveness of decontamination, as well as clearance for the affected population to reoccupy previously contaminated areas. One of the first SAPs developed was for the determin
DEMONSTRATION BULLETIN: SOIL/SEDIMENT WASHING SYSTEM BERGMANN USA
The Bergmann USA Soil/Sediment Washing System is a waste minimization technique designed to separate or "partition" soils and sediments by grain size and density. In this water-based volume reduction process, hazardous contaminants are concentrated into a small residual portion...
MICROBIAL SOURCE TRACKING GUIDE DOCUMENT
Approximately 13% of surface waters in the United States do not meet designated use criteria as determined by high densities of fecal indicator bacteria. Although some of the contamination is attributed to point sources such as confined animal feeding operation (CAFO) and wastew...
Wales, Andrew; Breslin, Mark; Davies, Robert
2006-09-10
Salmonella infection of laying flocks in the UK is predominantly a problem of the persistent contamination of layer houses and associated wildlife vectors by Salmonella Enteritidis. Methods for its control and elimination include effective cleaning and disinfection of layer houses between flocks, and it is important to be able to measure the success of such decontamination. A method for the environmental detection and semi-quantitative enumeration of salmonellae was used and compared with a standard qualitative method, in 12 Salmonella-contaminated caged layer houses before and after cleaning and disinfection. The quantitative technique proved to have comparable sensitivity to the standard method, and additionally provided insights into the numerical Salmonella challenge that replacement flocks would encounter. Elimination of S. Enteritidis was not achieved in any of the premises examined although substantial reductions in the prevalence and numbers of salmonellae were demonstrated, whilst in others an increase in contamination was observed after cleaning and disinfection. Particular problems with feeders and wildlife vectors were highlighted. The use of a quantitative method assisted the identification of problem areas, such as those with a high initial bacterial load or those experiencing only a modest reduction in bacterial count following decontamination.
NASA Astrophysics Data System (ADS)
Cumpson, Peter J.; Sano, Naoko; Barlow, Anders J.; Portoles, Jose F.
2013-10-01
Mercury contamination and the build-up of carbonaceous contamination are two contributing factors to the instability observed in kilogram prototype masses. The kilogram prototypes that lie at the core of the dissemination of the SI base unit were manufactured in the late 19th century, and have polished surfaces. In papers IV and V of this series we developed a method for cleaning noble metal mass standards in air to remove carbonaceous contamination. At the core of this ‘UVOPS’ protocol is the application of UV light and ozone gas generated in situ in air. The precise nature of the carbonaceous contamination that builds up on such surfaces is difficult to mimic demonstrably or quickly on new test surfaces, yet data from such tests are needed to provide the final confidence to allow UVOPS to be applied to a real 19th century kilogram prototype. Therefore, in the present work we have applied the UVOPS method to clean a platinum avoirdupois pound mass standard, ‘RS2’, manufactured in the mid-19th century. This is thought to have been polished in a similar manner to the kilogram prototypes. To our knowledge this platinum surface has not previously been cleaned by any method. We used x-ray photoelectron spectroscopy to identify organic contamination, and weighing to quantify the mass lost at each application of the UVOPS procedure. The UVOPS procedure is shown to be very effective. It is likely that the redefinition of the kilogram will require mass comparisons in vacuum in the years to come. Therefore, in addition to UVOPS a cleaning method for use in vacuum will also be needed. We introduce and evaluate gas cluster ion-beam (GCIB) treatment as a potential method for cleaning reference masses in vacuum. Again, application of this GCIB cleaning to a real artefact, RS2, allows us to make a realistic evaluation of its performance. While it has some attractive features, we cannot recommend it for cleaning mass standards in its present form.
Medalie, Laura; Martin, Jeffrey D.
2017-08-14
Potential contamination bias was estimated for 8 nutrient analytes and 40 pesticides in stream water collected by the U.S. Geological Survey at 147 stream sites from across the United States, and representing a variety of hydrologic conditions and site types, for water years 2002–12. This study updates previous U.S. Geological Survey evaluations of potential contamination bias for nutrients and pesticides. Contamination is potentially introduced to water samples by exposure to airborne gases and particulates, from inadequate cleaning of sampling or analytic equipment, and from inadvertent sources during sample collection, field processing, shipment, and laboratory analysis. Potential contamination bias, based on frequency and magnitude of detections in field blanks, is used to determine whether or under what conditions environmental data might need to be qualified for the interpretation of results in the context of comparisons with background levels, drinking-water standards, aquatic-life criteria or benchmarks, or human-health benchmarks. Environmental samples for which contamination bias as determined in this report applies are those from historical U.S. Geological Survey water-quality networks or programs that were collected during the same time frame and according to the same protocols and that were analyzed in the same laboratory as field blanks described in this report.Results from field blanks for ammonia, nitrite, nitrite plus nitrate, orthophosphate, and total phosphorus were partitioned by analytical method; results from the most commonly used analytical method for total phosphorus were further partitioned by date. Depending on the analytical method, 3.8, 9.2, or 26.9 percent of environmental samples, the last of these percentages pertaining to all results from 2007 through 2012, were potentially affected by ammonia contamination. Nitrite contamination potentially affected up to 2.6 percent of environmental samples collected between 2002 and 2006 and affected about 3.3 percent of samples collected between 2007 and 2012. The percentages of environmental samples collected between 2002 and 2011 that were potentially affected by nitrite plus nitrate contamination were 7.3 for samples analyzed with the low-level method and 0.4 for samples analyzed with the standard-level method. These percentages increased to 14.8 and 2.2 for samples collected in 2012 and analyzed using replacement low- and standard-level methods, respectively. The maximum potentially affected concentrations for nitrite and for nitrite plus nitrate were much less than their respective maximum contamination levels for drinking-water standards. Although contamination from particulate nitrogen can potentially affect up to 21.2 percent and that from total Kjeldahl nitrogen can affect up to 16.5 percent of environmental samples, there are no critical or background levels for these substances.For total nitrogen, orthophosphate, and total phosphorus, contamination in a small percentage of environmental samples might be consequential for comparisons relative to impairment risks or background levels. At the low ends of the respective ranges of impairment risk for these nutrients, contamination in up to 5 percent of stream samples could account for at least 23 percent of measured concentrations of total nitrogen, for at least 40 or 90 percent of concentrations of orthophosphate, depending on the analytical method, and for 31 to 76 percent of concentrations of total phosphorus, depending on the time period.Twenty-six pesticides had no detections in field blanks. Atrazine with 12 and metolachlor with 11 had the highest number of detections, mostly occurring in spring or early summer. At a 99-percent level of confidence, contamination was estimated to be no greater than the detection limit in at least 98 percent of all samples for 38 of 40 pesticides. For metolachlor and atrazine, potential contamination was no greater than 0.0053 and 0.0093 micrograms per liter in 98 percent of samples. For 11 of 14 pesticides with at least one detection, the maximum potentially affected concentration of the environmental sample was less than their respective human-health or aquatic-life benchmarks. Small percentages of environmental samples had concentrations high enough that atrazine contamination potentially could account for the entire aquatic-life benchmark for acute effects on nonvascular plants, that dieldrin contamination could account for up to 100 percent of the cancer health-based screening level, or that chlorpyrifos contamination could account for 13 or 12 percent of the concentrations in the aquatic-life benchmarks for chronic effects on invertebrates or the criterion continuous concentration for chronic effects on aquatic life.
Stable Isotopes Reveal Nitrogen Loading to Lake Tanganyika from Remote Shoreline Villages
NASA Astrophysics Data System (ADS)
Kelly, Brianne; Mtiti, Emmanuel; McIntyre, Peter B.; Vadeboncoeur, Yvonne
2017-02-01
Access to safe water is an ongoing challenge in rural areas in Tanzania where communities often lack access to improved sanitation. Methods to detect contamination of surface water bodies, such as monitoring nutrient concentrations and bacterial counts, are time consuming and results can be highly variable in space and time. On the northeast shore of Lake Tanganyika, Tanzania, the low population density coupled with the high potential for dilution in the lake necessitates the development of a sensitive method for detecting contamination in order to avoid human health concerns. We investigated the potential use of nitrogen and carbon stable isotopes of snail tissues to detect anthropogenic nutrient loading along the northeast shore of Lake Tanganyika. δ15N of snails was positively related to human population size in the nearest village, but only for villages with >4000 inhabitants. The areal footprint of villages within their watershed was also significantly correlated with snail δ15N, while agricultural land use and natural vegetation were not. Dissolved nutrient concentrations were not significantly different between village and reference sites. Our results indicate that nitrogen isotopes provide a sensitive index of local nutrient loading that can be used to monitor contamination of oligotrophic aquatic environments with low surrounding population densities.
A survey of the geophysical properties of chlorinated DNAPLs
NASA Astrophysics Data System (ADS)
Ajo-Franklin, Jonathan B.; Geller, Jil T.; Harris, Jerry M.
2006-07-01
Dense Non Aqueous Phase Liquids (DNAPLs) are a family of fluids often encountered as industrial contaminants. Some of the most problematic DNAPLs are chlorinated solvents such as trichloroethylene (TCE) and tetrachloroethylene (PCE). While many DNAPLs have been extensively studied from a hydrology perspective, documentation of DNAPL properties relevant to geophysical detection is far from complete. We present a short survey of acoustic velocity, density, and dielectric constant measurements for an important subset of commonly encountered dense chlorinated contaminants. Viscosity and surface tension data are included to allow exploration of contaminant signatures within the context of poroelastic or contact theory models. Where available, the temperature dependence of solvent properties are also provided. Densities for the listed DNAPLs range from 1253 to 1622 kg/m 3 at 20 °C. All are effectively non-polar with dielectric constants between 2.2 and 10.9 and have relatively low compressional wave velocities ranging from 938 to 1217 m/s. We conclude with documentation of a small collection of recent experiments investigating the properties of soils partially saturated with similar fluids. Current laboratory evidence demonstrates that DNAPLs can produce changes in geophysically measurable properties. We hope that this survey will facilitate further studies of the feasibility and effectiveness of geophysical techniques for detection of DNAPLs in the subsurface.
Waller, Sarah E; Mann, Jennifer E; Rothgeb, David W; Jarrold, Caroline C
2012-10-04
Results of a study combining anion photoelectron spectroscopy and density functional theory calculations on the heteronuclear MoNbO(y)(-) (y = 2-5) transition metal suboxide cluster series are reported and analyzed. The photoelectron spectra, which exhibit broad electronic bands with partially resolved vibrational structure, were compared to spectral simulations generated from calculated spectroscopic parameters for all computationally determined energetically competitive structures. Although computational results on the less oxidized clusters could not be satisfactorily reconciled with experimental spectra, possibly because of heavy spin contamination found in a large portion of the computational results, the results suggest that (1) neutral cluster electron affinity is a strong indicator of whether O-atoms are bound in M-O-M bridge positions or M═O terminal positions, (2) MoNbO(y) anions and neutrals have structures that can be described as intermediate with respect to the unary (homonuclear) Mo(2)O(y) and Nb(2)O(y) clusters, and (3) structures in which O-atoms preferentially bind to the Nb center are slightly more stable than alternative structures. Several challenges associated with the calculations are considered, including spin contamination, which appears to cause spurious single point calculations used to determine vertical detachment energies.
Crépet, Amélie; Albert, Isabelle; Dervin, Catherine; Carlin, Frédéric
2007-01-01
A normal distribution and a mixture model of two normal distributions in a Bayesian approach using prevalence and concentration data were used to establish the distribution of contamination of the food-borne pathogenic bacteria Listeria monocytogenes in unprocessed and minimally processed fresh vegetables. A total of 165 prevalence studies, including 15 studies with concentration data, were taken from the scientific literature and from technical reports and used for statistical analysis. The predicted mean of the normal distribution of the logarithms of viable L. monocytogenes per gram of fresh vegetables was −2.63 log viable L. monocytogenes organisms/g, and its standard deviation was 1.48 log viable L. monocytogenes organisms/g. These values were determined by considering one contaminated sample in prevalence studies in which samples are in fact negative. This deliberate overestimation is necessary to complete calculations. With the mixture model, the predicted mean of the distribution of the logarithm of viable L. monocytogenes per gram of fresh vegetables was −3.38 log viable L. monocytogenes organisms/g and its standard deviation was 1.46 log viable L. monocytogenes organisms/g. The probabilities of fresh unprocessed and minimally processed vegetables being contaminated with concentrations higher than 1, 2, and 3 log viable L. monocytogenes organisms/g were 1.44, 0.63, and 0.17%, respectively. Introducing a sensitivity rate of 80 or 95% in the mixture model had a small effect on the estimation of the contamination. In contrast, introducing a low sensitivity rate (40%) resulted in marked differences, especially for high percentiles. There was a significantly lower estimation of contamination in the papers and reports of 2000 to 2005 than in those of 1988 to 1999 and a lower estimation of contamination of leafy salads than that of sprouts and other vegetables. The interest of the mixture model for the estimation of microbial contamination is discussed. PMID:17098926
Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2011-01-01
The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface-water for contaminants at the Old Incinerator Area at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Total petroleum hydrocarbons were detected above the method detection level in all 13 samplers deployed in the hyporheic zone and flood plain of an unnamed tributary to Spirit Creek. The combined concentrations of benzene, toluene, ethylbenzene, and total xylene were detected at 3 of the 13 samplers. Other organic compounds detected in one sampler included octane and trichloroethylene. In the passive soil-gas survey, 28 of the 60 samplers detected total petroleum hydrocarbons above the method detection level. Additionally, 11 of the 60 samplers detected the combined masses of benzene, toluene, ethylbenzene, and total xylene above the method detection level. Other compounds detected above the method detection level in the passive soil-gas survey included octane, trimethylbenzene, perchlorethylene, and chloroform. Subsequent to the passive soil-gas survey, six areas determined to have relatively high contaminant mass were selected, and soil-gas samplers were deployed, collected, and analyzed for explosives and chemical agents. No explosives or chemical agents were detected above their method detection levels, but those that were detected were above the nondetection level. The same six locations that were sampled for explosives and chemical agents were selected for the collection of soil samples. No metals that exceeded the Regional Screening Levels for Industrial Soils as classified by the U.S. Environmental Protection Agency were detected at any of the six Old Incinerator Area locations. The soil samples also were compared to values from the ambient, uncontaminated (background) levels for soils in South Carolina. Because South Carolina is adjacent to Georgia and the soils in the coastal plain are similar, these comparisons are valid. No similar values are available for Georgia to use for comparison purposes. The only metal detected above the ambient background levels for South Carolina was barium. A surface-water sample collected from a tributary west and north of the Old Incinerator Area was analyzed for volatile organic compounds, semivolatile organic compounds, and inorganic compounds (metals). The only volatile organic and (or) semivolatile organic compound that was detected above the laboratory reporting level was toluene. The compounds 4-isopropyl-1-methylbenzene and isophorone were detected above the nondetection level but below the laboratory reporting level and were estimated. These compounds were detected at levels below the maximum contaminant levels set by the U.S. Environmental Protection Agency National Primary Drinking Water Standard. Iron was the only inorganic compound detected in the surface-water sample that exceeded the maximum contaminant level set by the U.S. Environmental Protection Agency National Secondary Drinking Water Standard. No other inorganic compounds exceeded the maximum contaminant levels for the U.S. Environmental Protection Agency National Primary Drinking Water Standard, National Secondary Drinking Water Standard, or the Georgia In-Stream Water Quality Standard.
Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography.
Haider, Irfanullah; Morgan, Matthew; McGow, Anna; Stein, Matthew; Rezvani, Maryam; Freer, Phoebe; Hu, Nan; Fajardo, Laurie; Winkler, Nicole
2018-06-12
To evaluate perceptual difference in breast density classification using synthesized mammography (SM) compared with standard or full-field digital mammography (FFDM) for screening. This institutional review board-approved, retrospective, multireader study evaluated breast density on 200 patients who underwent baseline screening mammogram during which both SM and FFDM were obtained contemporaneously from June 1, 2016, through November 30, 2016. Qualitative breast density was independently assigned by seven readers initially evaluating FFDM alone. Then, in a separate session, these same readers assigned breast density using synthetic views alone on the same 200 patients. The readers were again blinded to each other's assignment. Qualitative density assessment was based on BI-RADS fifth edition. Interreader agreement was evaluated with κ statistic using 95% confidence intervals. Testing for homogeneity in paired proportions was performed using McNemar's test with a level of significance of .05. For patients across the SM and standard 2-D data set, diagnostic testing with McNemar's test with P = 0.32 demonstrates that the minimal density transitions across FFDM and SM are not statistically significant density shifts. Taking clinical significance into account, only 8 of 200 (4%) patients had clinically significant transition (dense versus not dense). There was substantial interreader agreement with overall κ in FFDM of 0.71 (minimum 0.53, maximum 0.81) and overall SM κ average of 0.63 (minimum 0.56, maximum 0.87). Overall subjective breast density assignment by radiologists on SM is similar to density assignment on standard 2-D mammogram. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Speciation and bioaccessibility of mercury in adobe bricks and dirt floors in Huancavelica, Peru.
Hagan, Nicole; Robins, Nicholas; Gonzales, Ruben Dario Espinoza; Hsu-Kim, Heileen
2015-04-01
Huancavelica, Peru, a historic cinnabar refining site, is one of the most mercury (Hg)-contaminated urban areas in the world. Exposure is amplified because residents build their adobe brick homes from contaminated soil. The objectives of this study were to compare two Hg-leaching procedures, and their application as risk-assessment screening tools in Hg-contaminated adobe brick homes in Huancavelica. The purpose was to evaluate potential health implications, particularly for children, after ingestion of Hg-contaminated particles. Hg was measured in adobe brick and dirt floor samples from 60 households by total Hg extraction, simulated gastric fluid (GF) extraction, and sequential selective extraction (SSE), which provides more detailed data but is resource-intensive. Most of the Hg present in samples was relatively insoluble, although in some households soluble Hg species were present at concentrations that may be of concern after ingestion. A strong correlation was identified between results from simulated GF extraction of adobe bricks and dirt floors and the more soluble fractions of Hg from SSE. Simulated GF extraction data were combined with ingestion and body mass characteristics for small children to compare potential risk of ingestion of Hg-contaminated soil with current health standards. Simulated GF extraction can be used as a risk assessment screening tool for effective allocation of time and resources to households that have measurable concentrations of bioaccessible Hg. Combining simulated GF extraction data with health standards enables intervention strategies targeted at households with the greatest potential health threat from ingestion of Hg-contaminated particles.
A proposed approach for the assessment of chemicals in indirect potable reuse schemes.
Rodriguez, Clemencia; Weinstein, Philip; Cook, Angus; Devine, Brian; Van Buynder, Paul
2007-10-01
The city of Perth in Western Australia is facing a future of compromised water supplies. In recent years, this urban region has been experiencing rapid population growth, coupled with drying climate, which has exacerbated water shortages. As part of the government strategy to secure water sustainability and to address an agenda focused on all elements of the water cycle, a target of 20% reuse of treated wastewater by 2012 was established. This includes a feasibility review of managed aquifer recharge for indirect potable reuse. A characterization of contaminants in wastewater after treatment and an assessment of the health implications are necessary to reassure both regulators and the public. To date, the commonly used approach involves a comparison of measured contaminant concentrations with the established drinking-water standards or other toxicological guidelines for the protection of human health. However, guidelines and standards have not been established for many contaminants in recycled water (unregulated chemicals). This article presents a three-tiered approach for the preliminary health risk assessment of chemicals in order to determine key contaminants that need to be monitored and managed. The proposed benchmark values for the calculation of risk quotients are health based, systematically defined, scientifically defensible, easy to apply, and clear to interpret. The proposed methodology is based on the derivation of health-based levels for unregulated contaminants with toxicity information and a "threshold of toxicological concern" for unregulated contaminants without toxicity data. The application of this approach will help policymakers set guidelines regarding unregulated chemicals in recycled water.
Haiden, N; Pimpel, B; Assadian, O; Binder, C; Kreissl, A; Repa, A; Thanhäuser, M; Roberts, C D; Berger, A
2016-03-01
Bacterial counts in 1466 expressed breast milk (EBM) samples from women following one of two infection control regimens (standard vs strict) were investigated. Overall, 12% of samples yielded Gram-negative bacteria, with no significant differences between the standard [11.9% (94/788)] and strict [12.1% (82/678)] regimens (P = 0.92). Significantly more samples were contaminated when expressed at home (standard regimen home/hospital: 17.9% vs 6.1%; strict regimen home/hospital: 19.6% vs 3.4%; P < 0.001). Bacterial contamination of EBM was not associated with the regimen, but was associated with the location of breast milk expression. Attempts to improve personal hygiene during milk collection seem to be of limited value. Good hygiene of collection and storage equipment is likely to be the most important way to ensure the microbiological quality of EBM. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Pawlowska, Teresa E.; Chaney, Rufus L.; Chin, Mel; Charvat, Iris
2000-01-01
Phytoextraction involves use of plants to remove toxic metals from soil. We examined the effects of phytoextraction practices with three plant species (Silene vulgaris, Thlaspi caerulescens, and Zea mays) and a factorial variation of soil amendments (either an ammonium or nitrate source of nitrogen and the presence or absence of an elemental sulfur supplement) on arbuscular mycorrhizal (AM) fungi (Glomales, Zygomycetes) at a moderately metal-contaminated landfill located in St. Paul, Minn. Specifically, we tested whether the applied treatments affected the density of glomalean spores and AM root colonization in maize. Glomalean fungi from the landfill were grouped into two morphotypes characterized by either light-colored spores (LCS) or dark-colored spores (DCS). Dominant species of the LCS morphotype were Glomus mosseae and an unidentified Glomus sp., whereas the DCS morphotype was dominated by Glomus constrictum. The density of spores of the LCS morphotype from the phytoremediated area was lower than the density of these spores in the untreated landfill soil. Within the experimental area, spore density of the LCS morphotype in the rhizosphere of mycorrhizal maize was significantly higher than in rhizospheres of nonmycorrhizal S. vulgaris or T. caerulescens. Sulfur supplement increased vesicular root colonization in maize and exerted a negative effect on spore density in maize rhizosphere. We conclude that phytoextraction practices, e.g., the choice of plant species and soil amendments, may have a great impact on the quantity and species composition of glomalean propagules as well as on mycorrhiza functioning during long-term metal-remediation treatments. PMID:10831433
NASA Astrophysics Data System (ADS)
Toledo, J.; Manzaneque, T.; Ruiz-Díez, V.; Jiménez-Márquez, F.; Kucera, M.; Pfusterschmied, G.; Wistrela, E.; Schmid, U.; Sánchez-Rojas, J. L.
2015-05-01
Real-time monitoring of the physical properties of liquids is an important subject in the automotive industry. Contamination of lubricating oil by diesel soot has a significant impact on engine wear. Resonant microstructures are regarded to be a precise and compact solution for tracking the viscosity and density of lubricant oils. Since the measurement of pure shear forces do not allow an independent determination of the density and viscosity, two out-of-plane modes for the monitoring of oil dilution with diesel have been selected. The first one (12-mode) is working at 51 kHz and the second mode (14-mode) at 340 kHz. Two parameters were measured: the quality factor and the resonance frequency from which the viscosity and density of the fluids under test can be determined, requiring only a small amount of test liquid. A PLL-based oscillator circuit was implemented based on each resonator. Our results demonstrate the performance of the resonator in oils with viscosity up to 90 mPa·s. The quality factor measured at 25°C was 7 for the 12-mode and 19 for the 14-mode. A better resolution in density and viscosity was obtained for the 14-mode, showing a resolution of 3.92·10-5 g/ml for the density and 1.27·10-1 mPa·s for the viscosity, in pure lubricant oil SAE 0W30. An alternative tracking system, based on a discrete oscillator circuit, was tested with the same resonator, showing a comparable stability and supporting our approach.
Interactions of an insecticide with competition and pond drying in amphibian communities
Boone, M.D.; Semlitsch, R.D.
2002-01-01
Amphibian populations are often imbedded in agricultural landscapes. Therefore the potential for contamination of their habitat is considerable. Our study examined the effects of an insecticide (carbaryl, a neurotoxin), on larval amphibian communities experiencing natural stresses of competition for resources, predation, and pond drying. In a set of experimental ponds, tadpoles of three anuran species (southern leopard frog [Rana sphenocephala], plains leopard frog [R. blairi], and the Woodhouse's toad [Bufo woodhousii]) were added to 1000-L ponds containing leaf litter, plankton, two newts (Notophthalmus viridescens), and four overwintered green frog (R. clamitans) tadpoles. We manipulated the overall tadpole density (low or high), pond hydroperiod (constant or drying), and chemical exposure (0, 3.5, 5.0, or 7.0 mg/L carbaryl) of the ponds. We measured mass, time, and survival to metamorphosis to determine treatment effects. Carbaryl positively affected Woodhouse's toad survival, although it had a negligible effect on both leopard frog species. Tadpole density interacted with the chemical treatment: Proportionately more Woodhouse's toads survived to metamorphosis in high-density environments than in low-density or control environments. Greater survival may be an indirect effect of increased algal food resources from carbaryl exposure. Most newts lost mass over the course of the experiment, although ponds with drying hydroperiods and high anuran density were the least favorable environments. Overwintered green frogs exposed to carbaryl had longer larval periods on average than did green frogs in control ponds. Our study demonstrated that even sublethal, short-lived contaminants can alter natural communities in ways that cannot be predicted from simple, one-factor studies.
Comparison of methods to control floor contamination in an animal research facility.
Allen, Kenneth P; Csida, Tarrant; Leming, Jeaninne; Murray, Kathleen; Gauld, Stephen B; Thulin, Joseph
2012-10-01
The authors evaluated the effectiveness of adhesive mats, contamination control flooring, and shoe covers in decreasing the presence of microbial agents on animal holding room floors and footwear. Swab samples taken from animal holding room floors after the use of each product were compared with samples taken from rooms after no products were used. Swab samples were also taken from the heels and soles of the footwear of animal care staff before and after use of each product. The use of contamination control flooring or shoe covers significantly reduced the amount of organic material (as indicated by ATP levels measured by a luminometer) present on floors. Bacterial and ATP contamination of footwear was significantly lower after the use of shoe covers than after the use of adhesive mats or contamination control flooring, and the use of shoe covers led to a greater decrease in contamination before and after use than did use of either of the other two products. Although shoe covers were superior to both adhesive mats and contamination control flooring for decreasing contamination of animal room floors and footwear, facilities must take into account the contamination control standards required, the cost of the product, and the labor and time associated with product use when deciding which contamination control practices to implement.
Decontamination Equipment Standards Workshop for Civilian First Responders
2009-12-01
Hazardous Materials Decontamination Radiological Survey Nuclear Chemical 16. SECURITY CLASSIFICATION OF: a. REPORT u b. ABSTRACT u c. THIS...Washington, DC) sponsored the production of this material under an Interagency Agreement with the National Institute of Standards and Technology...responders currently use wet decontamination (i.e., soap and water) to remove contamination from personnel, the standard will not be specific to the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nostrand, J.D. Van; Wu, L.; Wu, W.M.
2010-08-15
A pilot-scale system was established to examine the feasibility of in situ U(VI) immobilization at a highly contaminated aquifer (U.S. DOE Integrated Field Research Challenge site, Oak Ridge, TN). Ethanol was injected intermittently as an electron donor to stimulate microbial U(VI) reduction, and U(VI) concentrations fell to below the Environmental Protection Agency drinking water standard (0.03 mg liter{sup -1}). Microbial communities from three monitoring wells were examined during active U(VI) reduction and maintenance phases with GeoChip, a high-density, comprehensive functional gene array. The overall microbial community structure exhibited a considerable shift over the remediation phases examined. GeoChip-based analysis revealed thatmore » Fe(III)-reducing bacterial (FeRB), nitrate-reducing bacterial (NRB), and sulfate-reducing bacterial (SRB) functional populations reached their highest levels during the active U(VI) reduction phase (days 137 to 370), in which denitrification and Fe(III) and sulfate reduction occurred sequentially. A gradual decrease in these functional populations occurred when reduction reactions stabilized, suggesting that these functional populations could play an important role in both active U(VI) reduction and maintenance of the stability of reduced U(IV). These results suggest that addition of electron donors stimulated the microbial community to create biogeochemical conditions favorable to U(VI) reduction and prevent the reduced U(IV) from reoxidation and that functional FeRB, SRB, and NRB populations within this system played key roles in this process.« less
Van Nostrand, Joy D.; Wu, Liyou; Wu, Wei-Min; Huang, Zhijian; Gentry, Terry J.; Deng, Ye; Carley, Jack; Carroll, Sue; He, Zhili; Gu, Baohua; Luo, Jian; Criddle, Craig S.; Watson, David B.; Jardine, Philip M.; Marsh, Terence L.; Tiedje, James M.; Hazen, Terry C.; Zhou, Jizhong
2011-01-01
A pilot-scale system was established to examine the feasibility of in situ U(VI) immobilization at a highly contaminated aquifer (U.S. DOE Integrated Field Research Challenge site, Oak Ridge, TN). Ethanol was injected intermittently as an electron donor to stimulate microbial U(VI) reduction, and U(VI) concentrations fell to below the Environmental Protection Agency drinking water standard (0.03 mg liter−1). Microbial communities from three monitoring wells were examined during active U(VI) reduction and maintenance phases with GeoChip, a high-density, comprehensive functional gene array. The overall microbial community structure exhibited a considerable shift over the remediation phases examined. GeoChip-based analysis revealed that Fe(III)-reducing bacterial (FeRB), nitrate-reducing bacterial (NRB), and sulfate-reducing bacterial (SRB) functional populations reached their highest levels during the active U(VI) reduction phase (days 137 to 370), in which denitrification and Fe(III) and sulfate reduction occurred sequentially. A gradual decrease in these functional populations occurred when reduction reactions stabilized, suggesting that these functional populations could play an important role in both active U(VI) reduction and maintenance of the stability of reduced U(IV). These results suggest that addition of electron donors stimulated the microbial community to create biogeochemical conditions favorable to U(VI) reduction and prevent the reduced U(IV) from reoxidation and that functional FeRB, SRB, and NRB populations within this system played key roles in this process. PMID:21498771
New quantum number for the many-electron Dirac-Coulomb Hamiltonian
NASA Astrophysics Data System (ADS)
Komorovsky, Stanislav; Repisky, Michal; Bučinský, Lukáš
2016-11-01
By breaking the spin symmetry in the relativistic domain, a powerful tool in physical sciences was lost. In this work, we examine an alternative of spin symmetry for systems described by the many-electron Dirac-Coulomb Hamiltonian. We show that the square of many-electron operator K+, defined as a sum of individual single-electron time-reversal (TR) operators, is a linear Hermitian operator which commutes with the Dirac-Coulomb Hamiltonian in a finite Fock subspace. In contrast to the square of a standard unitary many-electron TR operator K , the K+2 has a rich eigenspectrum having potential to substitute spin symmetry in the relativistic domain. We demonstrate that K+ is connected to K through an exponential mapping, in the same way as spin operators are mapped to the spin rotational group. Consequently, we call K+ the generator of the many-electron TR symmetry. By diagonalizing the operator K+2 in the basis of Kramers-restricted Slater determinants, we introduce the relativistic variant of configuration state functions (CSF), denoted as Kramers CSF. A new quantum number associated with K+2 has potential to be used in many areas, for instance, (a) to design effective spin Hamiltonians for electron spin resonance spectroscopy of heavy-element containing systems; (b) to increase efficiency of methods for the solution of many-electron problems in relativistic computational chemistry and physics; (c) to define Kramers contamination in unrestricted density functional and Hartree-Fock theory as a relativistic analog of the spin contamination in the nonrelativistic domain.
NASA Astrophysics Data System (ADS)
Tada, Kohei; Koga, Hiroaki; Okumura, Mitsutaka; Tanaka, Shingo
2018-06-01
Spin contamination error in the total energy of the Au2/MgO system was estimated using the density functional theory/plane-wave scheme and approximate spin projection methods. This is the first investigation in which the errors in chemical phenomena on a periodic surface are estimated. The spin contamination error of the system was 0.06 eV. This value is smaller than that of the dissociation of Au2 in the gas phase (0.10 eV). This is because of the destabilization of the singlet spin state due to the weakening of the Au-Au interaction caused by the Au-MgO interaction.
Impact of Sodium Contamination in Tin Sulfide Thin-Film Solar Cells
Steinmann, Vera; Brandt, Riley E.; Chakraborty, Rupak; ...
2016-02-12
Empirical observations show that sodium(Na) is a benign contaminant in some thin-filmsolar cells. Here, we intentionally contaminate thermally evaporated tin sulfide (SnS)thin-films with sodium and measure the SnS absorber properties and solar cellcharacteristics. The carrier concentration increases from 2 × 10 16 cm -3 to 4.3 × 10 17 cm -3 in Na-doped SnSthin-films, when using a 13 nm NaCl seed layer, which is detrimental for SnS photovoltaic applications but could make Na-doped SnS an attractive candidate in thermoelectrics. We observed trends in carrier concentration and found that it is in good agreement with density functional theory calculations, which predictmore » an acceptor-type NaSn defect with low formation energy.« less
Refurbishing of carbon contaminated pre-mirror of reflectivity beam line at Indus-1
NASA Astrophysics Data System (ADS)
Yadav, P. K.; Kumar, M.; Gupta, R. K.; Sinha, M.; Patel, H. S.; Modi, M. H.
2018-04-01
In recent days optics contamination and its refurbishing is a serious issue for synchrotron radiation beam line community. Here we refurbished a carbon contaminated mirror by Ar and O2 gas mixed (1:1) radio frequency plasma. For structural analysis pre and post characterization of the mirror was done by Soft X-ray reflectivity (SXRR), Raman Spectroscopy (RS) and Atomic force microscopy (AFM). Before refurbishing mirror, a low density graphitic carbon layer of thickness 400 Å with surface roughness about 55 Å and Au surface roughness 14Å was estimated by SXRR. After one hour RF plasma exposure it is observed by SXRR and Raman spectroscopy that carbon layer is completely removed. The AFM and SXRR results show that roughness of Au surface not increase after plasma exposure.
Phytoextraction of Cd-contaminated soil by carambola (Averrhoa carambola) in field trials.
Li, J T; Liao, B; Dai, Z Y; Zhu, R; Shu, W S
2009-08-01
Use of metal-accumulating woody species to extract metals from heavy metal contaminated soil has received more attention. While considerable studies have focused on the phytoextraction potential of willow (Salix spp.) and poplar (Populus spp.), similar information is rare for other woody species. Carambola (Averrhoa carambola) is a high-biomass tree and has been identified as a new Cd-accumulating species. The present study aimed to evaluate the Cd phytoextraction potential of carambola under field condition. After growing in a slightly Cd-contaminated site for about 170 d, the carambola stand initiated by seed-seedling with high planting density (encoded with "HD-1yr") attained a high shoot biomass yield of 18.6 t ha(-1) and extracted 213 g Cdha(-1), resulting in a 1.6-fold higher Cd removal efficiency than that of a contrasting stand established by grafted-seedling with low planting density (5.3% vs. 2%). That is, "HD-1yr" would remove 50% of the total soil Cd with 13yr, assuming that the Cd removal efficiency would not change over time. Further, one crop of "HD-1yr" significantly decreased (63-69%) the Cd uptake by subsequent vegetables. Among the four carambola stands established using grafted-seedling, the 2-yr-old stand exhibited the highest annual Cd removal efficiency (3.7%), which was yet lower than that of "HD-1yr". These results suggested that phytoextraction of Cd by carambola (especially for "HD-1yr" stand) presented a feasible option to clean up agricultural soils slightly contaminated by Cd.
Ruan, Ling; Han, Ge; Zhu, Zhongmin; Zhang, Miao; Gong, Wei
2015-01-01
The accurate estimation of deposits adhering on insulators is of great significance to prevent pollution flashovers which cause huge costs worldwide. Researchers have developed sensors using different technologies to monitor insulator contamination on a fine time scale. However, there is lack of analysis of these data to reveal spatial and temporal characteristics of insulator contamination, and as a result the scheduling of periodical maintenance of power facilities is highly dependent on personal experience. Owing to the deployment of novel sensors, daily Equivalent Salt Deposit Density (ESDD) observations of over two years were collected and analyzed for the first time. Results from 16 sites distributed in four regions of Hubei demonstrated that spatial heterogeneity can be seen at both the fine and coarse geographical scales, suggesting that current polluted area maps are necessary but are not sufficient conditions to guide the maintenance of power facilities. Both the local emission and the regional air pollution condition exert evident influences on deposit accumulation. A relationship between ESDD and PM10 was revealed by using regression analysis, proving that air pollution exerts influence on pollution accumulations on insulators. Moreover, the seasonality of ESDD was discovered for the first time by means of time series analysis, which could help engineers select appropriate times to clean the contamination. Besides, the trend component shows that the ESDD increases in a negative exponential fashion with the accumulation date (ESDD = a − b × exp(−time)) at a long time scale in real environments. PMID:25643058
Takarabe, S; Yabuuchi, H; Morishita, J
2012-06-01
To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.
Effects of nonequilibrium ablation chemistry on Viking radio blackout.
NASA Technical Reports Server (NTRS)
Evans, J. S.; Schexnayder, C. J., Jr.; Grose, W. L.
1973-01-01
The length of the entry blackout period during descent of the Viking Lander into the Mars atmosphere is predicted from calculated profiles of electron density in the shock layer over the aeroshell. Nonequilibrium chemistry plays a key role in the calculation, both in the inviscid flow and in the boundary layer. This is especially true in the boundary layer contaminated with ablation material, for which nonequilibrium chemistry predicts electron densities two decades lower than the same case calculated with equilibrium chemistry.
Bacteriological water quality of Tulpehocken Creek basin, Berks and Lebanon Counties, Pennsylvania
Barker, James L.
1978-01-01
A four month intensive study of the bacteriological quality of water in the Tulpehocken Creek basin indicates that (1) the streams locally contain high densities of bacteria indicative of fecal contamination, (2) nonpoint waste sources, particularly livestock, are the dominant influence in the excessive bacteriological-indicator counts observed, and (3) retention time of water in the proposed Blue Marsh Lake is believed sufficient to reduce bacteria densities to acceptable levels except following intense rainfall and runoff events during normally low flow periods.
COMPOSITE SAMPLING FOR DETECTION OF COLIFORM BACTERIA IN WATER SUPPLY
Low densities of coliform bacteria introduced into distribution systems may survive in protected habitats. These organisms may interfere with and cause confusion in the use of the coliforms as indicators of sewage contamination of drinking water. Methods of increasing the probabi...
SHOULD LATITUDINAL ATMOSPHERIC TRACE VAPOR CONCENTRATIONS BE REPORTED ON A MASS DENSITY BASIS?
For the past several decades the issue of global atmospheric trace vapor migration has been of concern to environmental professionals concerned with global distillation/cold condensation of toxic compounds, contamination of remote ecosystems, global climate change and stratospher...
NASA Technical Reports Server (NTRS)
Troy, B. E., Jr.; Maier, E. J.
1975-01-01
The effects of the grid transparency and finite collector size on the values of thermal ion density and temperature determined by the standard RPA (retarding potential analyzer) analysis method are investigated. The current-voltage curves calculated for varying RPA parameters and a given ion mass, temperature, and density are analyzed by the standard RPA method. It is found that only small errors in temperature and density are introduced for an RPA with typical dimensions, and that even when the density error is substantial for nontypical dimensions, the temperature error remains minimum.
Modeling benzene permeation through drinking water high density polyethylene (HDPE) pipes.
Mao, Feng; Ong, Say Kee; Gaunt, James A
2015-09-01
Organic compounds such as benzene, toluene, ethyl benzene and o-, m-, and p-xylene from contaminated soil and groundwater may permeate through thermoplastic pipes which are used for the conveyance of drinking water in water distribution systems. In this study, permeation parameters of benzene in 25 mm (1 inch) standard inside dimension ratio (SIDR) 9 high density polyethylene (HDPE) pipes were estimated by fitting the measured data to a permeation model based on a combination of equilibrium partitioning and Fick's diffusion. For bulk concentrations between 6.0 and 67.5 mg/L in soil pore water, the concentration-dependent diffusion coefficients of benzene were found to range from 2.0×10(-9) to 2.8×10(-9) cm2/s while the solubility coefficient was determined to be 23.7. The simulated permeation curves of benzene for SIDR 9 and SIDR 7 series of HDPE pipes indicated that small diameter pipes were more vulnerable to permeation of benzene than large diameter pipes, and the breakthrough of benzene into the HDPE pipe was retarded and the corresponding permeation flux decreased with an increase of the pipe thickness. HDPE pipes exposed to an instantaneous plume exhibited distinguishable permeation characteristics from those exposed to a continuous source with a constant input. The properties of aquifer such as dispersion coefficients (DL) also influenced the permeation behavior of benzene through HDPE pipes.
Oates, R P; Mcmanus, Michelle; Subbiah, Seenivasan; Klein, David M; Kobelski, Robert
2017-07-14
Internal standards are essential in electrospray ionization liquid chromatography-mass spectrometry (ESI-LC-MS) to correct for systematic error associated with ionization suppression and/or enhancement. A wide array of instrument setups and interfaces has created difficulty in comparing the quantitation of absolute analyte response across laboratories. This communication demonstrates the use of primary standards as operational qualification standards for LC-MS instruments and their comparison with commonly accepted internal standards. In monitoring the performance of internal standards for perfluorinated compounds, potassium hydrogen phthalate (KHP) presented lower inter-day variability in instrument response than a commonly accepted deuterated perfluorinated internal standard (d3-PFOS), with percent relative standard deviations less than or equal to 6%. The inter-day precision of KHP was greater than d3-PFOS over a 28-day monitoring of perfluorooctanesulfonic acid (PFOS), across concentrations ranging from 0 to 100μg/L. The primary standard trometamol (Trizma) performed as well as known internal standards simeton and tris (2-chloroisopropyl) phosphate (TCPP), with intra-day precision of Trizma response as low as 7% RSD on day 28. The inter-day precision of Trizma response was found to be greater than simeton and TCPP, across concentrations of neonicotinoids ranging from 1 to 100μg/L. This study explores the potential of primary standards to be incorporated into LC-MS/MS methodology to improve the quantitative accuracy in environmental contaminant analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
10 CFR 61.23 - Standards for issuance of a license.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses § 61.23 Standards for issuance of a license. A license for the receipt, possession, and disposal of waste containing or contaminated with source, special nuclear, or byproduct material will be...
10 CFR 61.23 - Standards for issuance of a license.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses § 61.23 Standards for issuance of a license. A license for the receipt, possession, and disposal of waste containing or contaminated with source, special nuclear, or byproduct material will be...
10 CFR 61.23 - Standards for issuance of a license.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses § 61.23 Standards for issuance of a license. A license for the receipt, possession, and disposal of waste containing or contaminated with source, special nuclear, or byproduct material will be...
10 CFR 61.23 - Standards for issuance of a license.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses § 61.23 Standards for issuance of a license. A license for the receipt, possession, and disposal of waste containing or contaminated with source, special nuclear, or byproduct material will be...
10 CFR 61.23 - Standards for issuance of a license.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Licenses § 61.23 Standards for issuance of a license. A license for the receipt, possession, and disposal of waste containing or contaminated with source, special nuclear, or byproduct material will be...
Laser-induced contamination control for high-power lasers in space-based LIDAR missions
NASA Astrophysics Data System (ADS)
Alves, Jorge; Pettazzi, Federico; Tighe, Adrian; Wernham, Denny
2017-11-01
In the framework of the ADM-Aeolus satellite mission, successful test campaigns have been performed in ESTEC's laser laboratory, and the efficiency of several mitigation techniques against Laser-Induced Contamination (LIC) have been demonstrated for the ALADIN laser. These techniques include the standard contamination control methods of materials identification with particular tendency to cause LIC, reduction of the outgassing of organic materials by vacuum bake-out and shielding of optical surfaces from the contamination sources. Also novel mitigation methods such as in-situ cleaning via partial pressures, or the usage of molecular absorbers were demonstrated. In this context, a number of highly sensitive optical measurement techniques have been developed and tested to detect and monitor LIC deposits at nanometre level.
Development of a standardized differential-reflective bioassay for microbial pathogens
NASA Astrophysics Data System (ADS)
Wilhelm, Jay; Auld, J. R. X.; Smith, James E.
2008-04-01
This research examines standardizing a method for the rapid/semi-automated identification of microbial contaminates. It introduces a method suited to test for food/water contamination, serology, urinalysis and saliva testing for any >1 micron sized molecule that can be effectively bound to an identifying marker with exclusivity. This optical biosensor method seeks to integrate the semi-manual distribution of a collected sample onto a "transparent" substrate array of binding sites that will then be applied to a standard optical data disk and run for analysis. The detection of most microbe species is possible in this platform because the relative scale is greater than the resolution of the standard-scale digital information on a standard CD or DVD. This paper explains the critical first stage in the advance of this detection concept. This work has concentrated on developing the necessary software component needed to perform highly sensitive small-scale recognition using the standard optical disk as a detection platform. Physical testing has made significant progress in demonstrating the ability to utilize a standard optical drive for the purposes of micro-scale detection through the exploitation of CIRC error correction. Testing has also shown a definable trend in the optimum scale and geometry of micro-arrayed attachment sites for the technology's concept to reach achievement.
Reusability of contaminated seed crystal for cast quasi-single crystalline silicon ingots
NASA Astrophysics Data System (ADS)
Li, Zaoyang; Liu, Lijun; Zhou, Genshu
2015-04-01
Reusing seed crystal is beneficial for reducing the production costs for cast quasi-single crystalline (QSC) silicon ingots. We numerically investigate the reusability of seed crystal in the casting processes with quartz crucible and silicon feedstock of different purities. The reused seed crystal is recycled from the standard QSC ingot and has been highly contaminated by iron impurity. Transient simulations of iron transport are carried out and special attention is paid to the diffusion and distribution characteristics of iron impurity at the ingot bottom. The heights of the bottom iron contaminated region are compared for silicon ingots grown from normal and recycled seed crystals. The results show that the purity of quartz crucible can influence the reusability of seed crystal more significantly than that of the feedstock. The recycled seed crystal with high iron concentration can be reused for casting processes with standard crucible, whereas it is not recommended for reusing for processes with pure crucible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-01
Accurate measurements of radioactivity in soils contaminated with Strontium-90 (Sr-90) or Uranium-238 (U-238) are essential for many DOE site remediation programs. These crucial measurements determine if excavation and soil removal is necessary, where remediation efforts should be focused, and/or if a site has reached closure. Measuring soil contamination by standard EPA laboratory methods typically takes a week (accelerated analytical test turnaround) or a month (standard analytical test turnaround). The time delay extends to operations involving heavy excavation equipment and associated personnel which are the main costs of remediation. This report describes an application of the BetaScint{trademark} fiber-optic sensor that measuresmore » Sr-90 or U-238 contamination in soil samples on site in about 20 minutes, at a much lower cost than time-consuming laboratory methods, to greatly facilitate remediation. This report describes the technology, its performance, its uses, cost, regulatory and policy issues, and lessons learned.« less
Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo
2015-01-01
OBJECTIVE: To evaluate the accuracy of diagnosing urinary tract infections using a new, recently described, standardized clean-catch collection technique. METHODS: Cross-sectional study of infants <90 days old admitted due to fever without a source, with two matched samples of urine obtained using two different methods: clean-catch standardized stimulation technique and bladder catheterization. RESULTS: Sixty paired urine cultures were obtained. The median age was 44-days-old. Seventeen percent were male infants. Clean-catch technique sensitivity was 97% (95% CI 82% to 100%) and specificity was 89% (95% CI 65% to 98%). The contamination rate of clean-catch samples was lower (5%) than the contamination rate of catheter specimens (8%). CONCLUSIONS: The sensitivity and specificity of urine cultures obtained using the clean-catch method through the new technique were accurate and the contamination rate was low. These results suggest that this technique is a valuable, alternative method for urinary tract infection diagnosis. PMID:26435675
Perron, Monique M; Burgess, Robert M; Suuberg, Eric M; Cantwell, Mark G; Pennell, Kelly G
2013-10-01
Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of 3 common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low-density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS)-coated solid-phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory-derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 ng/L to 18 ng/L for POM and 8.8 ng/L to 13 ng/L for PE using performance reference compound equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. © 2013 SETAC.
Chapter A7. Section 7.2. Fecal Indicator Viruses
Bushon, Rebecca N.
2003-01-01
More than 100 types of human pathogenic viruses may be present in fecal-contaminated waters. Coliphages are used as indicators of virus-related fecal contamination and of the microbiological quality of waters. This report provides information on the equipment, sampling protocols, and laboratory methods that are in standard use by U.S. Geological Survey (USGS) personnel for the collection of data on fecal indicator viruses.
Matthies, M
2003-04-11
For the prevention of future damages from chemicals at large contaminated sites, all transfer pathways leading to the exposure of man and vulnerable ecosystems have to be taken into account. For organic contaminants, the uptake into vegetation is the major entry route for the transfer into the food chains. Lipophilic substances are taken up by roots but are not translocated with the transpiration stream. Atmospheric background concentrations have a significant impact on foliage contamination due to the effective gaseous and particle deposition. Vegetables can also be contaminated after irrigation with contaminated water supplied by groundwater wells. By means of a multicompartment model, the various uptake processes into roots and foliage as well as the transformation and translocation processes are described and the concentration pattern resulting from daily irrigation with methyl-t-butyl ether in the edible parts is simulated. The results demonstrate the advantage of a dynamic multicompartment model over the static environmental quality standard approach in terms of derivation of possible exposure reduction measures for organic chemicals.
Ballent, Anika; Corcoran, Patricia L; Madden, Odile; Helm, Paul A; Longstaffe, Fred J
2016-09-15
Microplastics contamination of Lake Ontario sediments is investigated with the aim of identifying distribution patterns and hotspots in nearshore, tributary and beach depositional environments. Microplastics are concentrated in nearshore sediments in the vicinity of urban and industrial regions. In Humber Bay and Toronto Harbour microplastic concentrations were consistently >500 particles per kg dry sediment. Maximum concentrations of ~28,000 particles per kg dry sediment were determined in Etobicoke Creek. The microplastic particles were primarily fibres and fragments <2mm in size. Both low- and high-density plastics were identified using Raman spectroscopy. We provide a baseline for future monitoring and discuss potential sources of microplastics in terms of how and where to implement preventative measures to reduce the contaminant influx. Although the impacts of microplastics contamination on ecosystem health and functioning is uncertain, understanding, monitoring and preventing further microplastics contamination in Lake Ontario and the other Great Lakes is crucial. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Krzyżak, Jacek; Pogrzeba, Marta; Rusinowski, Szymon; Clifton-Brown, John; McCalmont, Jon Paul; Kiesel, Andreas; Mangold, Anja; Mos, Michal
2017-09-01
When heavy metal contaminated soils are excluded from food production, biomass crops offer an alternative commercial opportunity. Perennial crops have potential for phytoremediation. Whilst the conditions at heavy metal contaminated sites are challenging, successful phytoremediation would bring significant economic and social benefits. Seed-based Miscanthus hybrids were tested alongside the commercial clone Miscanthus × giganteus on arable land, contaminated with Pb, Cd and Zn near Katowice. Before the randomized experimental plots were established (25m2 plots with plant density 2/m2) `time-zero' soil samples were taken to determine initial levels of total (aqua regia) and bioavailable (CaCl2 extraction) concentration of Pb, Cd and Zn. After the growing season plant material was sampled during autumn (October, green harvest) and winter (March, brown harvest) to determine differences in heavy metal uptake. Results after the first growing season are presented, including the plot establishment success, biomass yield and heavy metal uptake.
Pulsed Plasma Thruster Contamination
NASA Technical Reports Server (NTRS)
Myers, Roger M.; Arrington, Lynn A.; Pencil, Eric J.; Carter, Justin; Heminger, Jason; Gatsonis, Nicolas
1996-01-01
Pulsed Plasma Thrusters (PPT's) are currently baselined for the Air Force Mightysat II.1 flight in 1999 and are under consideration for a number of other missions for primary propulsion, precision positioning, and attitude control functions. In this work, PPT plumes were characterized to assess their contamination characteristics. Diagnostics included planar and cylindrical Langmuir probes and a large number of collimated quartz contamination sensors. Measurements were made using a LES 8/9 flight PPT at 0.24, 0.39, 0.55, and 1.2 m from the thruster, as well as in the backflow region behind the thruster. Plasma measurements revealed a peak centerline ion density and velocity of approx. 6 x 10(exp 12) cm(exp -3) and 42,000 m/s, respectively. Optical transmittance measurements of the quartz sensors after 2 x 10(exp 5) pulses showed a rapid decrease in plume contamination with increasing angle from the plume axis, with a barely measurable transmittance decrease in the ultraviolet at 90 deg. No change in optical properties was detected for sensors in the backflow region.
Baseline studies of health status in north Atlantic Baleen whale populations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambertsen, R.H.
1988-09-01
This study investigated the health status of fin and sei whale populations of the central North Atlantic to establish a baseline for comparison with stranded whales in more heavily contaminated coastal zones. Systematic necropsy examinations were conducted on 150 fin whales and 42 sei whales caught by commercial whalers off the west coast of Iceland. Gas chromatographic measurements showed detectable tissue levels of organochlorine pesticides, but these levels were low, ranging from 0.2 ppb (gamma-BHC) to 1540 ppb (p,p{prime} DDE). Relevant to the comparative evaluation of contaminant effects was the finding that both the fin and sei whale, despite verymore » similar life histories, suffered from a distinct complement of natural disease problems. From the high incidence and contaminative route of transmission of the major parasitic diseases found, it is predicted that population-level health effects, including increments in mortality rate potentially caused by environmental contamination, will increase with population density.« less
Tutschku, S; Schantz, M M; Horvat, M; Logar, M; Akagi, H; Emons, H; Levenson, M; Wise, S A
2001-02-01
The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).
David W. MacFarlane; Neil R. Ver Planck
2012-01-01
Data from hardwood trees in Michigan were analyzed to investigate how differences in whole-tree form and wood density between trees of different stem diameter relate to residual error in standard-type biomass equations. The results suggested that whole-tree wood density, measured at breast height, explained a significant proportion of residual error in standard-type...
NASA Astrophysics Data System (ADS)
Odling, Noelle E.; Roden, Julie E.
1997-09-01
Some results from numerical models of flow and contaminant transport in fractured permeable rocks, where fractures are more conductive than rock matrix, are described. The 2D flow field in the fractured and permeable rock matrix is calculated using a finite difference, 'conductance mesh' method, and the contaminant transport is simulated by particle tracking methods using an advection-biased, random walk technique. The model is applied to simulated and naturally occurring fracture patterns. The simulated pattern is an en echelon array of unconnected fractures, as an example of a common, naturally occurring fracture geometry. Two natural fracture patterns are used: one of unconnected, sub-parallel fractures and one with oblique fracture sets which is well connected. Commonly occurring matrix permeability and fracture aperture values are chosen. The simulations show that the presence of fractures creates complex and heterogeneous flow fields and contaminant distribution in the permeable rock matrix. The modelling results have shown that some effects are non-intuitive and therefore difficult to foresee without the help of a model. With respect to contaminant transport rates and plume heterogeneity, it was found that fracture connectivity (crucial when the matrix is impermeable) can play a secondary role to fracture orientation and density. Connected fracture systems can produce smooth break-through curves of contaminants summed over, for example, a bore-hole length, whereas in detail the contaminant plume is spatially highly heterogeneous. Close to a constant-pressure boundary (e.g. an extraction bore-hole), flow and contaminants can be channelled by fractures. Thus observations at a bore-hole may suggest that contaminants are largely confined to the fracture system, when, in fact, significant contamination resides in the matrix.
Navab-Daneshmand, Tala; Friedrich, Max N. D.; Gächter, Marja; Montealegre, Maria Camila; Mlambo, Linn S.; Nhiwatiwa, Tamuka; Mosler, Hans-Joachim; Julian, Timothy R.
2018-01-01
Abstract. Escherichia coli pathotypes (i.e., enteropathogenic and enterotoxigenic) have been identified among the pathogens most responsible for moderate-to-severe diarrhea in low- and middle-income countries (LMICs). Pathogenic E. coli are transmitted from infected human or animal feces to new susceptible hosts via environmental reservoirs such as hands, water, and soil. Commensal E. coli, which includes nonpathogenic E. coli strains, are widely used as fecal bacteria indicator, with their presence associated with increased likelihood of enteric pathogens and/or diarrheal disease. In this study, we investigated E. coli contamination in environmental reservoirs within households (N = 142) in high-population density communities of Harare, Zimbabwe. We further assessed the interconnectedness of the environmental compartments by investigating associations between, and household-level risk factors for, E. coli contamination. From the data we collected, the source and risk factors for E. coli contamination are not readily apparent. One notable exception is the presence of running tap water on the household plot, which is associated with significantly less E. coli contamination of drinking water, handwashing water, and hands after handwashing. In addition, E. coli levels on hands after washing are significantly associated with handwashing water contamination, hand contamination before washing, and diarrhea incidence. Finally, we observed that animal ownership increases E. coli contamination in soil, and E. coli in soil are correlated with contamination on hands before washing. This study highlights the complexity of E. coli contamination in household environments within LMICs. More, larger, studies are needed to better identify sources and exposure pathways of E. coli—and enteric pathogens generally—to identify effective interventions. PMID:29363444
Navab-Daneshmand, Tala; Friedrich, Max N D; Gächter, Marja; Montealegre, Maria Camila; Mlambo, Linn S; Nhiwatiwa, Tamuka; Mosler, Hans-Joachim; Julian, Timothy R
2018-03-01
Escherichia coli pathotypes (i.e., enteropathogenic and enterotoxigenic) have been identified among the pathogens most responsible for moderate-to-severe diarrhea in low- and middle-income countries (LMICs). Pathogenic E. coli are transmitted from infected human or animal feces to new susceptible hosts via environmental reservoirs such as hands, water, and soil. Commensal E. coli , which includes nonpathogenic E. coli strains, are widely used as fecal bacteria indicator, with their presence associated with increased likelihood of enteric pathogens and/or diarrheal disease. In this study, we investigated E. coli contamination in environmental reservoirs within households ( N = 142) in high-population density communities of Harare, Zimbabwe. We further assessed the interconnectedness of the environmental compartments by investigating associations between, and household-level risk factors for, E. coli contamination. From the data we collected, the source and risk factors for E. coli contamination are not readily apparent. One notable exception is the presence of running tap water on the household plot, which is associated with significantly less E. coli contamination of drinking water, handwashing water, and hands after handwashing. In addition, E. coli levels on hands after washing are significantly associated with handwashing water contamination, hand contamination before washing, and diarrhea incidence. Finally, we observed that animal ownership increases E. coli contamination in soil, and E. coli in soil are correlated with contamination on hands before washing. This study highlights the complexity of E. coli contamination in household environments within LMICs. More, larger, studies are needed to better identify sources and exposure pathways of E. coli -and enteric pathogens generally-to identify effective interventions.
Airborne bacterial contaminations in typical Chinese wet market with live poultry trade.
Gao, Xin-Lei; Shao, Ming-Fei; Luo, Yi; Dong, Yu-Fang; Ouyang, Feng; Dong, Wen-Yi; Li, Ji
2016-12-01
Chinese wet markets with live poultry trade have been considered as major sources of pathogen dissemination, and sites for horizontal transfer of bacterial and viral pathogens. In this study, the pathogenic bacteria and antibiotic resistant genes (ARGs) in air samples collected at a typical Chinese wet market had been analysis and quantified. Corynebacterium minutissimum and other pathogenic bacteria accounted for 0.81-8.02% of the whole microbial community in different air samples. The four ARGs quantified in this study showed a comparable relative concentration (copies/ng_DNA) with municipal wastewater. Poultry manures were demonstrated to be important microbial contamination source in wet market, which was supported by both microbial composition based source tracking and the quantification of airborne microbial density. A series of Firmicutes and Bacteroidetes indicators of poultry area contamination were successfully screened, which will be useful for the more convenient monitoring of airborne poultry area contamination. Our results indicate bioaerosols acted as important route for the transmissions of pathogens and ARGs. Continued surveillance of airborne microbial contamination is required in poultry trade wet market. Urban live poultry markets are important sources of pathogen dissemination, and sites for horizontal transfer of viral and bacterial pathogens. In the present field-study, pathogenic bacteria and antibiotic resistance genes were focused to provide quantitative information on the levels of microbial contaminations at the indoor air of wet markets. Results demonstrated that poultry manures were important microbial contamination source in wet market, and in the meanwhile bioaerosols were identified as important route for the transmissions of microbial contaminants. A series of Firmicutes and Bacteroidetes indicators of poultry area contamination were successfully screened, which will be useful for the more convenient monitoring of airborne poultry area contamination. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-06-01
The U.S. Environmental Protection Agency (EPA) has established health and environmental regulations to correct and prevent ground water contamination resulting from former uranium processing activities at inactive uranium processing sites (40 CFR Part 192 (1993)) (52 FR 36000 (1978)). According to the Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978 (42 USC {section} 7901 et seq.), the U.S. Department of Energy (DOE) is responsible for assessing the inactive uranium processing sites. The DOE has decided that each assessment will include information on hydrogeologic site characterization. The water resources protection strategy that describes the proposed action compliance with the EPAmore » ground water protection standards is presented in Attachment 4, Water Resources Protection Strategy. Site characterization activities discussed in this section include the following: (1) Definition of the hydrogeologic characteristics of the environment, including hydrostratigraphy, aquifer parameters, areas of aquifer recharge and discharge, potentiometric surfaces, and ground water velocities. (2) Definition of background ground water quality and comparison with proposed EPA ground water protection standards. (3) Evaluation of the physical and chemical characteristics of the contaminant source and/or residual radioactive materials. (4) Definition of existing ground water contamination by comparison with the EPA ground water protection standards. (5) Description of the geochemical processes that affect the migration of the source contaminants at the processing site. (6) Description of water resource use, including availability, current and future use and value, and alternate water supplies.« less
Li, Xinyu; Li, Zhonggen; Lin, Che-Jen; Bi, Xiangyang; Liu, Jinling; Feng, Xinbin; Zhang, Hua; Chen, Ji; Wu, Tingting
2018-06-04
Smelting of nonferrous metals is an important source of heavy metals in surface soil. The crops/vegetables grown on contaminated soil potentially impose adverse effects on human health. In this study, the contamination level of five heavy metals (Hg, Pb, Zn, Cd and Cu) in ten types of vegetables grown nearby a large scale Pb/Zn smelter in Hunan Province, China and the health risk associated with their consumption are assessed. Based on the data obtained from 52 samples, we find that Pb and Cd contributed to the greatest health risk and leafy vegetables tend to be more contaminated than non-leafy vegetables. Within 4 km radius of the smelter, over 75% of vegetable samples exceeded the national food standard for Pb; over 47% exceeded the Cd standard; and 7% exceeded the Hg standard. Heavy metal concentrations in vegetables measured within the 4 km radius are on average three times more elevated compared to those found at the control area 15 km away. Heavy metals in vegetables have dual sources of root absorption from soil and leaf adsorption from atmosphere. Health risk in terms of the hazard index (HI) at contaminated areas are 3.66 and 3.14 for adults and children, respectively, suggesting adverse health effects would occur. HI for both groups are mainly contributed by Pb (48%) and Cd (40%). Fortunately, vegetable samples collected at the control area are considered safe to consume. Copyright © 2018 Elsevier Inc. All rights reserved.
Watson-Leung, Trudy; Graham, Matt; Hartman, Erin; Welsh, Paul G
2017-01-01
Potential adverse impacts to the aquatic environment should be minimized whenever possible during an environmental dredging project by selecting realistic and technically feasible environmental targets. These targets need to balance short term impacts with the longer term benefit of removing contaminated sediments from the environment. Environmental dredging is part of the planned remediation of Randle Reef (a 60 hectare zone of mostly PAH-contaminated sediments) in Hamilton, Ontario, Canada. In this study, we describe the results of dredging elutriate toxicity testing (DETE) to assess the potential risks from dredging this PAH contaminated site. A modified elutriate preparation method intended as an alternative measure of conditions within the dredging plume was assessed with both standard water column species (Daphnia magna and fathead minnow [Pimephales promelas]) and alternative benthic and epibenthic test organisms (Chironomus dilutus and Hyalella azteca). The standard DETE test was also conducted with H. azteca to compare with the modified DETE results. The greatest toxic response was seen in the alternative test species; however, the modified DETE method resulted in less toxicity than the standard protocol. The relationship between toxicity results and chemical and/or physical characteristics of the samples was examined, but differences in toxicity could only be explained by differences in the total suspended solids concentrations in the elutriate samples. Challenges associated with DETE assessment of PAH-contaminated sediments and the implications for establishing dredging benchmarks are discussed. Integr Environ Assess Manag 2017;13:155-166. © 2016 SETAC. © 2016 SETAC.
Environmental contamination due to shale gas development.
Annevelink, M P J A; Meesters, J A J; Hendriks, A J
2016-04-15
Shale gas development potentially contaminates both air and water compartments. To assist in governmental decision-making on future explorations, we reviewed scattered information on activities, emissions and concentrations related to shale gas development. We compared concentrations from monitoring programmes to quality standards as a first indication of environmental risks. Emissions could not be estimated accurately because of incomparable and insufficient data. Air and water concentrations range widely. Poor wastewater treatment posed the highest risk with concentrations exceeding both Natural Background Values (NBVs) by a factor 1000-10,000 and Lowest Quality Standards (LQSs) by a factor 10-100. Concentrations of salts, metals, volatile organic compounds (VOCs) and hydrocarbons exceeded aquatic ecotoxicological water standards. Future research must focus on measuring aerial and aquatic emissions of toxic chemicals, generalisation of experimental setups and measurement technics and further human and ecological risk assessment. Copyright © 2016 Elsevier B.V. All rights reserved.
Welle, F
2005-10-01
Six hundred conventional recycled HDPE flake samples, which were recollected and sorted in the UK, were screened for post-consumer contamination levels. Each analysed sample consisted of 40-50 individual flakes so that the amount of analysed individual containers was in the range 24,000-30,000 post-consumer milk bottles. Predominant contaminants in hot-washed flake samples were unsaturated oligomers, which can be also be found in virgin high-density polyethylene (HDPE) pellet samples used for milk bottle production. In addition, the flavour compound limonene, the degradation product of antioxidant additives di-tert-butylphenol and low amounts of saturated oligomers were found in higher concentrations in the post-consumer samples in comparison with virgin HDPE. However, the overall concentrations in post-consumer recycled samples were similar to or lower than concentration ranges in comparison with virgin HDPE. Contamination with other HDPE untypical compounds was rare and was in most cases related to non-milk bottles, which are <2.1% of the input material of the recycling process. The maximum concentration found in one sample of 1 g was estimated as 130 mg kg(-1), which corresponds to a contamination of 5200-6500 mg kg(-1) in the individual bottle. The recycling process investigated was based on an efficient sorting process, a hot-washing of the ground bottles, and a further deep-cleaning of the flakes with high temperatures and vacuum. Based on the fact that the contamination levels of post-consumer flake samples are similar to virgin HDPE and on the high cleaning efficiency of the super-clean recycling process especially for highly volatile compounds, the recycling process investigated is suitable for recycled post-consumer HDPE bottles for direct food-contact applications. However, hand-picking after automatically sorting is recommended to decrease the amount of non-milk bottles. The conclusions for suitability are valid, provided that the migration testing of recyclate contains milk bottles up to 100% and that both shelf-life testing and sensorial testing of the products are successful, which are topics of further investigations.
Ruddy, M.; McHugh, T. D.; Dale, J. W.; Banerjee, D.; Maguire, H.; Wilson, P.; Drobniewski, F.; Butcher, P.; Gillespie, S. H.
2002-01-01
Isolates from patients with confirmed tuberculosis from London were collected over 2.5 years between 1995 and 1997. Restriction fragment length polymorphism (RFLP) analysis was performed by the international standard technique as part of a multicenter epidemiological study. A total of 2,779 samples representing 2,500 individual patients from 56 laboratories were examined. Analysis of these samples revealed a laboratory cross-contamination rate of between 0.54%, when only presumed cases of cross-contamination were considered, and 0.93%, when presumed and possible cases were counted. Previous studies suggest an extremely wide range of laboratory cross-contamination rates of between 0.1 and 65%. These data indicate that laboratory cross-contamination has not been a common problem in routine practice in the London area, but in several incidents patients did receive full courses of therapy that were probably unnecessary. PMID:12409381
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-09-01
For the UMTRA Project site located near Durango, Colorado (the Durango site), the Surface Project cleanup occurred from 1986 to 1991. An evaluation was made to determine whether exposure to ground water contaminated by uranium processing could affect people`s health. Exposure could occur from drinking water pumped from a hypothetical well drilled in the contaminated ground water area. In addition, environmental risks may result if plants or animals are exposed to contaminated ground water, or surface water that has mixed with contaminated ground water. This risk assessment report is the first site-specific document prepared for the UMTRA Ground Water Projectmore » at the Durango site. The results of this report and further site characterization of the Durango site will be used to determine what is necessary to protect public health and the environment, and to comply with the EPA standards.« less
Trellu, Clément; Miltner, Anja; Gallo, Rosita; Huguenot, David; van Hullebusch, Eric D; Esposito, Giovanni; Oturan, Mehmet A; Kästner, Matthias
2017-04-05
Tar oil contamination is a major environmental concern due to health impacts of polycyclic aromatic hydrocarbons (PAH) and the difficulty of reaching acceptable remediation end-points. Six tar oil-contaminated soils with different industrial histories were compared to investigate contamination characteristics by black particles. Here we provide a simple method tested on 6 soils to visualize and identify large amounts of black particles (BP) as either solid aggregates of resinified and weathered tar oil or various wood/coke/coal-like materials derived from the contamination history. These materials contain 2-10 times higher PAH concentrations than the average soil and were dominantly found in the sand fraction containing 42-86% of the total PAH. The PAH contamination in the different granulometric fractions was directly proportional to the respective total organic carbon content, since the PAH were associated to the carbonaceous particulate materials. Significantly lower (bio)availability of PAH associated to these carbonaceous phases is widely recognized, thus limiting the efficiency of remediation techniques. We provide a conceptual model of the limited mass transfer of PAH from resinated tar oil phases to the water phase and emphasize the options to physically separate BP based on their lower bulk density and slower settling velocity. Copyright © 2017 Elsevier B.V. All rights reserved.
A PROBABILISTIC METHOD FOR ESTIMATING MONITORING POINT DENSITY FOR CONTAINMENT SYSTEM LEAK DETECTION
The use of physical and hydraulic containment systems for the isolation of contaminated ground water and aquifer materials ssociated with hazardous waste sites has increased during the last decade. The existing methodologies for monitoring and evaluating leakage from hazardous w...
EFFECT OF VARYING FLOW REGIMES ON BIOFILM DENSITIES IN A DISTRIBUTION SYSTEM SIMULATOR
Maintenance of a free chlorine residual within water distribution systems is used to reduce the possibility of microbial contamination. However, it has been demonstrated that biofilms within water distribution systems can harbor coliforms. In laboratory scale studies, others have...
Evaluating the precision of passive sampling methods using PRCs in the water column
Low-Density polyethylene (LDPE) sheets are often used as passive samplers for aquatic environmental monitoring to measure the dissolved concentrations of hydrophobic organic contaminants (HOCs). HOCs that are freely dissolved in water (Cfree) will partition into the LDPE until a ...
In situ flushing groundwater remediation technologies, such as cosolvent flushing, rely on the stability of the interface between the resident and displacing fluids for efficient removal of contaminants. Contrasts in density and viscosity between the resident and displacing flui...
Human Mitochondrial DNA and Endogenous Bacterial Surrogates for Risk Assessment of Graywater Reuse
Previous graywater risk assessment studies have focused on fecal contamination, yet the low density of fecal indicators may not provide the most useful approach to assess pathogen removal during graywater treatment. In this study, we employed high throughput bacterial sequencing ...
40 CFR 267.111 - What general standards must I meet when I stop operating the unit?
Code of Federal Regulations, 2011 CFR
2011-07-01
... to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or hazardous waste decomposition products to the ground or... PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE...
40 CFR 267.111 - What general standards must I meet when I stop operating the unit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... to protect human health and the environment, post-closure escape of hazardous waste, hazardous constituents, leachate, contaminated run-off, or hazardous waste decomposition products to the ground or... PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE...
40 CFR 268.45 - Treatment standards for hazardous debris.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Debris 1 Technology description Performance and/or design and operating standard Contaminant..., Cloth, Concrete, Paper, Pavement, Rock, Wood: Removal of at least 0.6 cm of the surface layer; treatment...: Treatment to a clean debris surface 3; Brick, Cloth, Concrete, Paper, Pavement, Rock, Wood: Debris must be...
40 CFR 268.45 - Treatment standards for hazardous debris.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Debris 1 Technology description Performance and/or design and operating standard Contaminant..., Cloth, Concrete, Paper, Pavement, Rock, Wood: Removal of at least 0.6 cm of the surface layer; treatment...: Treatment to a clean debris surface 3; Brick, Cloth, Concrete, Paper, Pavement, Rock, Wood: Debris must be...
40 CFR 268.45 - Treatment standards for hazardous debris.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Debris 1 Technology description Performance and/or design and operating standard Contaminant..., Cloth, Concrete, Paper, Pavement, Rock, Wood: Removal of at least 0.6 cm of the surface layer; treatment...: Treatment to a clean debris surface 3; Brick, Cloth, Concrete, Paper, Pavement, Rock, Wood: Debris must be...
40 CFR 268.45 - Treatment standards for hazardous debris.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hazardous Debris 1 Technology description Performance and/or design and operating standard Contaminant..., Cloth, Concrete, Paper, Pavement, Rock, Wood: Removal of at least 0.6 cm of the surface layer; treatment...: Treatment to a clean debris surface 3; Brick, Cloth, Concrete, Paper, Pavement, Rock, Wood: Debris must be...
40 CFR 268.45 - Treatment standards for hazardous debris.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hazardous Debris 1 Technology description Performance and/or design and operating standard Contaminant..., Cloth, Concrete, Paper, Pavement, Rock, Wood: Removal of at least 0.6 cm of the surface layer; treatment...: Treatment to a clean debris surface 3; Brick, Cloth, Concrete, Paper, Pavement, Rock, Wood: Debris must be...
Caron, Alexandra G M; Thomas, Colette R; Berry, Kathryn L E; Motti, Cherie A; Ariel, Ellen; Brodie, Jon E
2018-02-01
Ocean contamination by plastics is a global issue. Although ingestion of plastic debris by sea turtles has been widely documented, contamination by microplastics (<5mm) is poorly known and likely to be under-reported. We developed a microplastic extraction protocol for examining green turtle (Chelonia mydas) chyme, which is multifarious in nature, by modifying and combining pre-established methods used to separate microplastics from organic matter and sediments. This protocol consists of visual inspection, nitric acid digestion, emulsification of residual fat, density separation, and chemical identification by Fourier transform infrared spectroscopy. This protocol enables the extraction of polyethylene, high-density polyethylene, (aminoethyl) polystyrene, polypropylene, and polyvinyl chloride microplastics >100μm. Two macroplastics and seven microplastics (two plastic paint chips and five synthetic fabric particles) were isolated from subsamples of two green turtles. Our results highlight the need for more research towards understanding the impact of microplastics on these threatened marine reptiles. Copyright © 2018 Elsevier Ltd. All rights reserved.