Code of Federal Regulations, 2014 CFR
2014-07-01
... Population Emission Factors—Storage Wellheads, Gas Service Connector 0.01 Valve 0.1 Pressure Relief Valve 0.17 Open Ended Line 0.03 Population Emission Factors—Other Components, Gas Service Low Continuous... Bleed Pneumatic Device Vents 2 2.35 1 Valves include control valves, block valves and regulator valves...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Connector 5.59 Open-Ended Line 17.27 Pressure Relief Valve 39.66 Meter 19.33 Population Emission Factors... Population Emission Factors—Other Components, Gas Service Low Continuous Bleed Pneumatic Device Vents 2 1.37... Valves include control valves, block valves and regulator valves. 2 Emission Factor is in units of “scf...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Population Emission Factors—Storage Wellheads, Gas Service Connector 0.01 Valve 0.1 Pressure Relief Valve 0.17 Open Ended Line 0.03 Population Emission Factors—Other Components, Gas Service Low Continuous... Bleed Pneumatic Device Vents 2 2.35 1 Valves include control valves, block valves and regulator valves...
76 FR 2922 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-18
... in emissions through a requirement to retrofit or replace certain high bleed pneumatic controllers with ``low bleed'' components. The Department of Justice will receive for a period of thirty (30) days...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
Pneumatic shutoff and time-delay valve operates at controlled rate
NASA Technical Reports Server (NTRS)
Horning, J. L.; Tomlinson, L. E.
1966-01-01
Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.
Prediction and Reduction of Noise in Pneumatic Bleed Valves
NASA Astrophysics Data System (ADS)
Taghavi Nezhad, Shervin
This study investigates numerically the fluid mechanics and acoustics of pneumatic bleed valves used in turbofan engines. The goal is to characterized the fundamental processes of noise generation and devise strategies for noise reduction. Three different methods are employed for both analysis and redesign of the bleed valve to reduce noise. The bleed valve noise problem is carefully divided into multiple smaller problems. For large separations and tonal noises, the unsteady Reynolds-Averaged Navier-Stokes (URANS) method is utilized. This method is also applied in the re-designing of the bleed valve geometry. For the bleed valve muffler, which is comprised of perforated plates and a honeycomb, a Reynolds-Averaged Navier-Stokes (RANS) method combined with a simplified acoustic analogy is used. The original muffler design is modified to improve noise attenuation. Finally, for sound scattering through perforated plates, a fully implicit linearized Euler solver is developed. The problem of sound interaction with perforated plates is studied from two perspectives. In the first study the effect of high--speed mean flow is considered and it is shown that at Strouhal numbers of around 0.2-0.25 there is an increase in transmitted incident sound. In the second part, the interaction of holes in two--dimensional perforated plates is investigated using three different configurations. The study demonstrates that the hole interaction has a significant impact on sound attenuation, especially at high frequencies.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population Emission Factors—Gas... 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control valves, block valves...
Continued Development and Improvement of Pneumatic Heavy Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert J. Englar
2005-07-15
The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in themore » first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel economy evaluations, as described in Ref. 5. Both objectives are based on the pneumatic technology already developed and confirmed for DOE OHVT/OAAT in Phases I-V. This new Phase VI effort was initiated by contract amendment to the Phase V effort using carryover FY02 funds. This were conducted under a new and distinct project number, GTRI Project A-6935, separate from the Phase I-IV program. However, the two programs are closely integrated, and thus Phase VI continues with the previous program and goals.« less
Vignon, Philippe; Dequin, Pierre-François; Renault, Anne; Mathonnet, Armelle; Paleiron, Nicolas; Imbert, Audrey; Chatellier, Delphine; Gissot, Valérie; Lhéritier, Gwenaelle; Aboyans, Victor; Prat, Gwenael; Garot, Denis; Boulain, Thierry; Diehl, Jean-Luc; Bressollette, Luc; Delluc, Aurélien; Lacut, Karine
2013-05-01
Venous thromboembolism (VTE) is a frequent and serious problem in intensive care units (ICU). Anticoagulant treatments have demonstrated their efficacy in preventing VTE. However, when the bleeding risk is high, they are contraindicated, and mechanical devices are recommended. To date, mechanical prophylaxis has not been rigorously evaluated in any trials in ICU patients. In this multicenter, open-label, randomized trial with blinded evaluation of endpoints, we randomly assigned 407 patients with a high risk of bleeding to receive intermittent pneumatic compression (IPC) associated with graduated compression stockings (GCS) or GCS alone for 6 days during their ICU stay. The primary endpoint was the occurrence of a VTE between days 1 and 6, including nonfatal symptomatic documented VTE, or death due to a pulmonary embolism, or asymptomatic deep vein thrombosis detected by ultrasonography systematically performed on day 6. The primary outcome was assessed in 363 patients (89.2%). By day 6, the incidence of the primary outcome was 5.6% (10 of 179 patients) in the IPC + GCS group and 9.2% (17 of 184 patients) in the GCS group (relative risk 0.60; 95% confidence interval 0.28-1.28; p = 0.19). Tolerance of IPC was poor in only 12 patients (6.0%). No intergroup difference in mortality rate was observed. With the limitation of a low statistical power, our results do not support the superiority of the combination of IPC + GCS compared to GCS alone to prevent VTE in ICU patients at high risk of bleeding.
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...
46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
49 CFR 574.6 - Identification mark.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.6... retreaded pneumatic tires, non-pneumatic tires or non-pneumatic tire assemblies shall apply in writing to... Street SW., Washington, DC 20590, identify itself as a tire manufacturer or retreader and furnish the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin
PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complicationsmore » were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.« less
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
Sandberg, E C; Pelligra, R
1983-07-01
Three patients with abdominal pregnancy have been treated at Stanford University Hospital in recent years. Common to each was surgically uncontrolled hemorrhage for which circumferential pneumatic compression (supplied by a medical antigravity suit) was used to stop the bleeding. In each patient, the hemostatic effect of treatment was dramatic. In published accounts of the use of the garment in other severely hemorrhaging patients, the effects have been similarly dramatic and equally successful. These observations lead to a compelling consideration in regard to optimum management of patients with abdominal pregnancy. If our experience is confirmed by others, optimum management in abdominal pregnancy hereafter should regularly and routinely include removal of the placenta at the primary operation. This approach would anticipate use of the medical antigravity suit to provide hemostasis if surgically uncontrollable bleeding is encountered. Theoretically, the complications and long-term morbidity associated with retention of the placenta would be eliminated by this means while the previous disadvantage of placental removal, the potential for exsanguinating hemorrhage, would be circumvented.
Therapeutic esophageal interventions for dysphagia and bleeding.
Siersema, Peter D
2006-07-01
This article reviews the most notable results of esophageal interventions for dysphagia and bleeding published in 2005. Long-term rubber tube placement was shown to be an interesting treatment option for difficult esophageal strictures. Two studies demonstrated that only 50% of patients who had undergone pneumatic dilation for achalasia were dysphagia-free after long-term follow-up. It was shown that patients with dysphagia from esophageal cancer should be treated by intraluminal radiotherapy (brachytherapy), whereas stent placement was preferable in those with a poor prognosis. Temporary stent placement is an option in patients undergoing radiotherapy for inoperable esophageal cancer to increase the dysphagia-free period. Two studies were published on the successful use of silicone-covered plastic stents for sealing of leaks after surgery of the esophagus. The optimal treatment for bleeding varices was confirmed to be endoscopic band ligation. A meta-analysis demonstrated that adding sclerotherapy to band ligation for secondary prophylaxis of bleeding varices had no effect on clinical outcome. In 2005, new techniques for the treatment of complicated strictures were presented. In addition, expanding indications for stents were reported. Finally, endoscopic band ligation was confirmed to be the most optimal technique for the treatment of varices.
Pneumatic Muscle Actuated Equipment for Continuous Passive Motion
NASA Astrophysics Data System (ADS)
Deaconescu, Tudor T.; Deaconescu, Andrea I.
2009-10-01
Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.
A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.
Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.
A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset
Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455
Wu, Haifu; Zhong, Ming; Zhou, Di; Shi, Chenye; Jiao, Heng; Wu, Wei; Chang, Xinxia; Cang, Jing; Bian, Hua
2017-04-25
Surgical operation in treating obesity and type 2 diabetes is popularizing rapidly in China. Correct prevention and recognition of perioperation-related operative complications is the premise of ensuring surgical safety. Familiar complications of the operation include deep venous thrombosis, pulmonary artery embolism, anastomotic bleeding, anastomotic fistula and marginal ulcer. The prevention of deep venous thrombosis is better than treatment. The concrete measures contain physical prophylaxis (graduated compression stocking and intermittent pneumatic compression leg sleeves) and drug prophylaxis (unfractionated heparin and low molecular heparin), and the treatment is mainly thrombolysis or operative thrombectomy. The treatment of pulmonary artery embolism includes remittance of pulmonary arterial hypertension, anticoagulation, thrombolysis, operative thrombectomy, interventional therapy and extracorporeal membrane oxygenation (ECMO). Hemorrhage is a rarely occurred but relatively serious complication after bariatric surgery. The primary cause of anastomotic bleeding after laparoscopic gastric bypass is incomplete hemostasis or weak laparoscopic repair. The common bleeding site in laparoscopic sleeve gastrectomy is gastric stump and close to partes pylorica, and the bleeding may be induced by malformation and weak repair technique. Patients with hemodynamic instability caused by active bleeding or excessive bleeding should timely received surgical treatment. Anastomotic fistula in gastric bypass can be divided into gastrointestinal anastomotic fistula and jejunum-jejunum anastomotic fistula. The treatment of postoperative anastomotic fistula should vary with each individual, and conservative treatment or operative treatment should be adopted. Anastomotic stenosis is mainly related to the operative techniques. Stenosis after sleeve gastrectomy often occurs in gastric angle, and the treatment methods include balloon dilatation and stent implantation, and surgical treatment should be performed when necessary. Marginal ulcer after gastric bypass is a kind of peptic ulcer occurring close to small intestine mucosa in the junction point of stomach and jejunum. Ulcer will also occur in the vestige stomach after laparoscopic sleeve gastrectomy, and the occurrence site locates mostly in the gastric antrum incisal margin. Preoperative anti-HP (helicobacter pylorus) therapy and postoperative continuous administration of proton pump inhibitor (PPI) for six months is the main means to prevent and treat marginal ulcer. For patients on whom conservative treatment is invalid, endoscopic repair or surgical repair should be considered. Different surgical procedures will generate different related operative complications. Fully understanding and effectively dealing with the complications of various surgical procedures through multidisciplinary cooperation is a guarantee for successful operation.
2013-01-01
Background The primary objective of this study was to determine the efficiency of a pneumatic device in controlling cuff pressure (Pcuff) in patients intubated with polyurethane-cuffed tracheal tubes. Secondary objectives were to determine the impact of continuous control of Pcuff, and cuff shape on microaspiration of gastric contents. Methods Prospective randomized controlled study. All patients requiring intubation and mechanical ventilation ≥48 h were eligible. The first 32 patients were intubated with tapered polyurethane-cuffed, and the 32 following patients were intubated with cylindrical polyurethane-cuffed tracheal tubes. Patients randomly received 24 h of continuous control of Pcuff using a pneumatic device (Nosten®), and 24 h of routine care of Pcuff using a manometer. Target Pcuff was 25 cmH2O. Pcuff was continuously recorded, and pepsin was quantitatively measured in all tracheal aspirates during these periods. Results The pneumatic device was efficient in controlling Pcuff (med [IQ] 26 [24, 28] vs 22 [20, 28] cmH2O, during continuous control of Pcuff and routine care, respectively; p = 0.017). In addition, percentage of patients with underinflation (31% vs 68%) or overinflation (53% vs 100%) of tracheal cuff, and percentage of time spent with underinflation (0.9 [0, 17] vs 14% [4, 30]) or overinflation (0 [0, 2] vs 32% [9, 54]) were significantly (p < 0.001) reduced during continuous control of Pcuff compared with routine care. No significant difference was found in microaspiration of gastric content between continuous control of Pcuff compared with routine care, or between patients intubated with tapered compared with cylindrical polyurethane-cuffed tracheal tubes. Conclusion The pneumatic device was efficient in controlling Pcuff in critically ill patients intubated with polyurethane-cuffed tracheal tubes. Trial registration The Australian New Zealand Clinical Trials Registry (NCT01351259) PMID:24369057
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.4 Applicability. This... retreaded tires, and new non-pneumatic tires and non-pneumatic tire assemblies for use on motor vehicles... does not apply to persons who retread tires solely for their own use. [36 FR 5422, Mar. 23, 1971, as...
Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.
Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W
2011-11-01
To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that unfractionated heparin and intermittent pneumatic compression are both superior to placebo or no intervention but insufficient to determine whether heparins are superior to intermittent pneumatic compression for venous thromboembolism prevention. Combining two of three risks (aged 60 years or older, cancer, or personal venous thromboembolism history) substantially elevated the risk of venous thromboembolism. Intermittent pneumatic compression provides sufficient prophylaxis for the majority of gynecology patients undergoing benign surgery. Additional risk factors warrant the use of combined mechanical and pharmacologic prophylaxis.
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review
NASA Astrophysics Data System (ADS)
De Volder, Michaël; Reynaerts, Dominiek
2010-04-01
The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
Sulak, Patricia J; Smith, Virginia; Coffee, Andrea; Witt, Iris; Kuehl, Alicia L; Kuehl, Thomas J
2008-09-01
To assess bleeding patterns with continuous use of the transvaginal contraceptive ring. We did a prospective analysis of daily menstrual flow during a 21/7 cycle followed by 6 months of continuous use and institution of a randomized protocol to manage breakthrough bleeding/spotting. Seventy-four women completed the baseline 21/7 phase and were randomized equally into two groups during the continuous phase. Group 1 was instructed to replace the ring monthly on the same calendar day with no ring-free days. Group 2 was instructed to use the same process, but if breakthrough bleeding/spotting occurred for 5 days or more, they were to remove the ring for 4 days, store it, and then reinsert that ring. Sixty-five women completed the continuous phase with reduced average flow scores in the continuous phase compared with the 21/7 phase (P<.02). Most patients had no to minimal bleeding during continuous use, with group 2 experiencing a statistically greater percentage of days without breakthrough bleeding or spotting (95%) compared with group 1 (89%) (P=.016). Instituting a 4-day hormone-free interval was more (P<.001) effective in resolving breakthrough bleeding/spotting than continuing ring use. A reduction in bleeding occurred during continuous use with replacement of the transvaginal ring compared with baseline 21/7 use. Continuous vaginal ring use resulted in an acceptable bleeding profile in most patients, reduction in flow, reduction in pelvic pain, and a high continuation rate.
Pneumatic gap sensor and method
Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.
1992-01-01
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.
Pneumatic gap sensor and method
Bagdal, K.T.; King, E.L.; Follstaedt, D.W.
1992-03-03
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.
Kim, Seung Young; Hyun, Jong Jin; Suh, Sang Jun; Jung, Sung Woo; Jung, Young Kul; Koo, Ja Seol; Yim, Hyung Joon; Park, Jong Jae; Chun, Hoon Jai; Lee, Sang Woo
2016-04-01
To evaluate whether the risk of cardiovascular events increases when antithrombotics are discontinued after ulcer bleeding. Peptic ulcer bleeding associated with antithrombotics has increased due to the increase in the proportion of elderly population. Little is known about the long-term effects of discontinuing antithrombotics after peptic ulcer bleeding. The aim of this study was to evaluate whether the risk of cardiovascular events increases when antithrombotics are discontinued after ulcer bleeding. We reviewed the medical records of patients with ulcer bleeding who were taking antiplatelet agents or anticoagulants at the time of ulcer bleeding. Cox-regression model was used to adjust for potential confounders, and analyzed association between discontinuation of antithrombotic drugs after ulcer bleeding and thrombotic events such as ischemic heart disease or stroke. Of the 544 patients with ulcer bleeding, 72 patients who were taking antithrombotics and followed up for >2 months were analyzed. Forty patients discontinued antithrombotics after ulcer bleeding (discontinuation group) and 32 patients continued antithrombotics with or without transient interruption (continuation group). Thrombotic events developed more often in discontinuation group than in the continuation group [7/32 (21.9%) vs. 1/40 (2.5%), P=0.019]. Hazard ratio for thrombotic event when antithrombotics were continuously discontinued was 10.9 (95% confidence interval, 1.3-89.7). There were no significant differences in recurrent bleeding events between the 2 groups. Discontinuation of antithrombotics after peptic ulcer bleeding increases the risk of cardiovascular events. Therefore, caution should be taken when discontinuing antithrombotics after ulcer bleeding.
Lee, Jae Woo; Nam, Young Joon; Choi, Ki Yong
2017-01-01
Background To assess the hemostatic effect of QuikClot Combat Gauze (QCG) compared to that of standard gauze during cruciate-retaining total knee arthroplasty (TKA). Methods Sixty knees underwent TKA using a pneumatic tourniquet in this prospective randomized study. After implantation of the femoral and tibial components and hardening of the bone cement, the tourniquet was deflated and QCG (group 1) or standard gauze (group 2) was packed into the joint cavity for 5 minutes for hemostasis. Perioperative bleeding volume and blood transfusion volume were compared between two groups. Results The mean intraoperative bleeding volume was 64.7 ± 12.7 mL in group 1 and 63.9 ± 9.2 mL in group 2 (p = 0.808). The mean postoperative blood drainage was 349.0 ± 170.6 mL in group 1 and 270.1 ± 136.3 mL in group 2 (p = 0.057). The average postoperative blood transfusion volume was 323.7 ± 325.9 mL in group 1 and 403.6 ± 274.8 mL in group 2 (p = 0.314). Conclusions QCG was not significantly effective for reducing perioperative bleeding volume or the blood transfusion rate compared with standard gauze during TKA. PMID:28261426
Kaneshiro, Bliss; Edelman, Alison; Carlson, Nichole; Morgan, Kristin; Nichols, Mark; Jensen, Jeffrey
2010-06-01
To estimate whether doxycycline, a matrix metalloproteinase inhibitor, would decrease unscheduled bleeding associated with initiation of a continuous oral contraceptive pill. Participants initiating a continuous oral contraceptive pill (20 micrograms of ethinyl estradiol/90 micrograms of levonorgestrel) were randomly assigned to receive either doxycycline (100 mg orally twice daily) or placebo taken for 5 days at the onset of each bleeding or spotting episode during the first 84 days of the study period. For the final 28 days of the study, participants were observed on the oral contraceptive pill alone. The primary outcome was the number of bleeding and spotting days. A sample size of 66 (33 in each arm) was calculated to detect a 50% reduction in bleeding (beta=0.80, alpha=0.05) and accounted for a 30% dropout rate. Sixty-six women were randomly assinged (33 in each study group). There were no significant differences during the 84-day treatment in bleeding or spotting days (doxycycline [mean {standard error}, placebo, P=.32) or the length of the longest bleeding or spotting episode (doxycycline, placebo, P=.70) between study groups. Similarly, no significant differences in bleeding patterns existed between groups during the final 28 days. Doxycycline, administered once bleeding has started, does not decrease unscheduled bleeding or shorten episodes of unscheduled bleeding in continuous oral contraceptive pill users. I.
... form of gum and jawbone disease known as periodontitis . Other causes of bleeding gums include: Any bleeding ... if: The bleeding is severe or long-term (chronic) Your gums continue to bleed even after treatment ...
NASA Astrophysics Data System (ADS)
Ferrara, T.; Howard, T. M.
2016-12-01
Studies attempting to reconcile facility level emission estimates of sources at oil and gas facilities with basin wide methane flux measurements have had limited success. Pneumatic devices are commonly used at oil and gas production facilities for process control or liquid pumping. These devices are powered by pressurized natural gas from the well, so they are known methane sources at these sites. Pneumatic devices are estimated to contribute 14% to 25% of the total greenhouse gas emissions (GHG) from production facilities. Measurements of pneumatic devices have shown that malfunctioning or poorly maintained control systems may be emitting significantly more methane than currently estimated. Emission inventories for these facilities use emission factors from EPA that are based on pneumatic device measurements made in the early 1990's. Recent studies of methane emissions from production facilities have attempted to measure emissions from pneumatic devices by several different methods. These methods have had limitations including alteration of the system being measured, the inability to distinguish between leaks and venting during normal operation, or insufficient response time to account of the time based emission events. We have developed a high speed recording high flow sampler that is capable of measuring the transient emissions from pneumatic devices. This sampler is based on the well-established high flow measurement technique used in oil and gas for quantifying component leak rates. In this paper we present the results of extensive laboratory controlled release testing. Additionally, test data from several field studies where this sampler has been used to measure pneumatic device emissions will be presented.
Closed-loop helium circulation system for actuation of a continuously operating heart catheter pump.
Karabegovic, Alen; Hinteregger, Markus; Janeczek, Christoph; Mohl, Werner; Gföhler, Margit
2017-06-09
Currently available, pneumatic-based medical devices are operated using closed-loop pulsatile or open continuous systems. Medical devices utilizing gases with a low atomic number in a continuous closed loop stream have not been documented to date. This work presents the construction of a portable helium circulation addressing the need for actuating a novel, pneumatically operated catheter pump. The design of its control system puts emphasis on the performance, safety and low running cost of the catheter pump. Static and dynamic characteristics of individual elements in the circulation are analyzed to ensure a proper operation of the system. The pneumatic circulation maximizes the working range of the drive unit inside the catheter pump while reducing the total size and noise production.Separate flow and pressure controllers position the turbine's working point into the stable region of the pressure creation element. A subsystem for rapid gas evacuation significantly decreases the duration of helium removal after a leak, reaching subatmospheric pressure in the intracorporeal catheter within several milliseconds. The system presented in the study offers an easy control of helium mass flow while ensuring stable behavior of its internal components.
Unscheduled bleeding with continuous oral contraceptive pills: a comparison of progestin dose.
Kaneshiro, Bliss; Edelman, Alison; Carlson, Nichole E; Nichols, Mark; Jensen, Jeffrey
2012-07-01
Although the use of continuous oral contraceptive pills (OCPs) eliminates scheduled uterine bleeding, unscheduled bleeding is common. The objective of this study was to determine whether progestin dose influences bleeding with use of continuous OCPs. This was a secondary data analysis of two other studies of continuous OCPs. Women were eligible if they were switching from a cyclic hormonal contraceptive to a continuous OCP. Women took a 20-mcg ethinyl estradiol (EE)/100-mcg levonorgestrel (LNG) pill or a 20-mcg EE/90-mcg LNG pill for 112 days. The number of bleeding/spotting days was compared between groups using a t test. Sample size was adequate to detect a difference of 8 days of bleeding/spotting over the 112 day study period (β=0.80, α=0.05). Sixty-six subjects were enrolled, 33 in each group. There were no differences in baseline characteristic, missed OCPs or side effects. There were no differences in the mean number of bleeding/spotting days in the first 84 days of the study (90 mcg LNG mean 20.8 (SE 3.6) days versus 100 mcg LNG 17.8 (SE 2.3) days, p=.48), nor was there a difference in the time to amenorrhea (p=.35). Our results do not support the use of one LNG dose over another to decrease the amount of unscheduled bleeding women experience when initiating a continuous OCP. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Roskam, J.; Rice, M.; Eysink, H.
1979-01-01
Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.
Sun, Yanwei; Wang, Yibing; Li, Liang; Zhang, Zheng; Wang, Ning; Wu, Dan
Discontinuation of aspirin therapy before cutaneous surgery may cause serious complications. The aim of this prospective study was to evaluate the bleeding risk of split-thickness skin transplantation repair to chronic wounds in patients on aspirin therapy. A total of 97 patients who underwent split-thickness skin transplantation surgery of chronic wounds during a 2-year period were enrolled. They were categorized on the basis of aspirin therapies. The primary outcome was postoperative bleeding and bleeding complications. Univariate analysis was performed to examine the association between aspirin and bleeding complications. Among the 26 patients taking aspirin continuously in group A, there were 5 bleeding complications (19.23%). Among the 55 nonusers in group B, there were 10 bleeding complications (18.18%). Among the 16 discontinuous patients in group C, there were 3 bleeding complications (18.75%). No statistical differences were found among the groups ( P = .956). Univariate analysis showed that continuous aspirin use was not significantly associated with bleeding complications (odds ratio, 0.933; 95% confidence interval, 0.283-3.074; P = .910 in the aspirin and control groups) and that discontinuous aspirin use was not significantly associated with bleeding complications (odds ratio, 0.963; 95% confidence interval, 0.230-4.025; P = .959 in the aspirin and control groups; odds ratio, 0.969; 95% confidence interval, 0.198-4.752; P = .969 in the aspirin and discontinuous groups). Continuous aspirin use does not produce an additional bleeding risk in patients who undergo split-thickness skin transplantation repair of chronic wounds.
Sriprasert, Intira; Beydoun, Hind; Barnabei, Vanessa; Nassir, Rami; LaCroix, Andrea Z; Archer, David F
2015-10-01
Endometrial spotting or bleeding is a common adverse effect among women taking continuous-combined estrogen-progestin therapy. The renin-angiotensin-aldosterone system plays a major role in hypertension and is present in the endometrium. We hypothesized that postmenopausal women with hypertension would have a higher incidence of bleeding compared with postmenopausal women without hypertension. A multivariate mixed-effects logistic model estimated the odds ratios for the relationship of hypertension status or use of antihypertensive drugs with endometrial bleeding using the Women's Health Initiative database. The incidence of spotting or bleeding in the first 12 months of estrogen-progestin use was 42% in women aged 50 to 79 years. Women with hypertension were more likely to experience bleeding than women without hypertension (odds ratio, 1.07; 95% CI, 1.02-1.13). Overall antihypertensive medication use increased bleeding with an odds ratio of 1.24, whereas angiotensin II receptor antagonists had a reduced odds ratio (0.53). Postmenopausal women with hypertension are more likely to bleed than postmenopausal women without hypertension when taking continuous estrogen-progestin, with less bleeding in women using angiotensin II receptor antagonists. This finding is novel and supports our hypothesis that the endometrial renin-angiotensin-aldosterone system may contribute to endometrial bleeding.
Long-term prognosis in patients continuing taking antithrombotics after peptic ulcer bleeding
Wang, Xi-Xu; Dong, Bo; Hong, Biao; Gong, Yi-Qun; Wang, Wei; Wang, Jue; Zhou, Zhen-Yu; Jiang, Wei-Jun
2017-01-01
AIM To investigate the long-term prognosis in peptic ulcer patients continuing taking antithrombotics after ulcer bleeding, and to determine the risk factors that influence the prognosis. METHODS All clinical data of peptic ulcer patients treated from January 1, 2009 to January 1, 2014 were retrospectively collected and analyzed. Patients were divided into either a continuing group to continue taking antithrombotic drugs after ulcer bleeding or a discontinuing group to discontinue antithrombotic drugs. The primary outcome of follow-up in peptic ulcer bleeding patients was recurrent bleeding, and secondary outcome was death or acute cardiovascular disease occurrence. The final date of follow-up was December 31, 2014. Basic demographic data, complications, and disease classifications were analyzed and compared by t- or χ2-test. The number of patients that achieved various outcomes was counted and analyzed statistically. A survival curve was drawn using the Kaplan-Meier method, and the difference was compared using the log-rank test. COX regression multivariate analysis was applied to analyze risk factors for the prognosis of peptic ulcer patients. RESULTS A total of 167 patients were enrolled into this study. As for the baseline information, differences in age, smoking, alcohol abuse, and acute cardiovascular diseases were statistically significant between the continuing and discontinuing groups (70.8 ± 11.4 vs 62.4 ± 12.0, P < 0.001; 8 (8.2%) vs 15 (21.7%), P < 0.05; 65 (66.3%) vs 13 (18.8%), P < 0.001). At the end of the study, 18 patients had recurrent bleeding and three patients died or had acute cardiovascular disease in the continuing group, while four patients had recurrent bleeding and 15 patients died or had acute cardiovascular disease in the discontinuing group. The differences in these results were statistically significant (P = 0.022, P = 0.000). The Kaplan-Meier survival curve indicated that the incidence of recurrent bleeding was higher in patients in the continuing group, and the risk of death and developing acute cardiovascular disease was higher in patients in the discontinuing group (log-rank test, P = 0.000 for both). Furthermore, COX regression multivariate analysis revealed that the hazard ratio (HR) for recurrent bleeding was 2.986 (95%CI: 067-8.356, P = 0.015) in the continuing group, while HR for death or acute cardiovascular disease was 5.216 (95%CI: 1.035-26.278, P = 0.028). CONCLUSION After the occurrence of peptic ulcer bleeding, continuing antithrombotics increases the risk of recurrent bleeding events, while discontinuing antithrombotics would increase the risk of death and developing cardiovascular disease. This suggests that clinicians should comprehensively consider the use of antithrombotics after peptic ulcer bleeding. PMID:28216980
Long-term prognosis in patients continuing taking antithrombotics after peptic ulcer bleeding.
Wang, Xi-Xu; Dong, Bo; Hong, Biao; Gong, Yi-Qun; Wang, Wei; Wang, Jue; Zhou, Zhen-Yu; Jiang, Wei-Jun
2017-01-28
To investigate the long-term prognosis in peptic ulcer patients continuing taking antithrombotics after ulcer bleeding, and to determine the risk factors that influence the prognosis. All clinical data of peptic ulcer patients treated from January 1, 2009 to January 1, 2014 were retrospectively collected and analyzed. Patients were divided into either a continuing group to continue taking antithrombotic drugs after ulcer bleeding or a discontinuing group to discontinue antithrombotic drugs. The primary outcome of follow-up in peptic ulcer bleeding patients was recurrent bleeding, and secondary outcome was death or acute cardiovascular disease occurrence. The final date of follow-up was December 31, 2014. Basic demographic data, complications, and disease classifications were analyzed and compared by t - or χ 2 -test. The number of patients that achieved various outcomes was counted and analyzed statistically. A survival curve was drawn using the Kaplan-Meier method, and the difference was compared using the log-rank test. COX regression multivariate analysis was applied to analyze risk factors for the prognosis of peptic ulcer patients. A total of 167 patients were enrolled into this study. As for the baseline information, differences in age, smoking, alcohol abuse, and acute cardiovascular diseases were statistically significant between the continuing and discontinuing groups (70.8 ± 11.4 vs 62.4 ± 12.0, P < 0.001; 8 (8.2%) vs 15 (21.7%), P < 0.05; 65 (66.3%) vs 13 (18.8%), P < 0.001). At the end of the study, 18 patients had recurrent bleeding and three patients died or had acute cardiovascular disease in the continuing group, while four patients had recurrent bleeding and 15 patients died or had acute cardiovascular disease in the discontinuing group. The differences in these results were statistically significant ( P = 0.022, P = 0.000). The Kaplan-Meier survival curve indicated that the incidence of recurrent bleeding was higher in patients in the continuing group, and the risk of death and developing acute cardiovascular disease was higher in patients in the discontinuing group (log-rank test, P = 0.000 for both). Furthermore, COX regression multivariate analysis revealed that the hazard ratio (HR) for recurrent bleeding was 2.986 (95%CI: 067-8.356, P = 0.015) in the continuing group, while HR for death or acute cardiovascular disease was 5.216 (95%CI: 1.035-26.278, P = 0.028). After the occurrence of peptic ulcer bleeding, continuing antithrombotics increases the risk of recurrent bleeding events, while discontinuing antithrombotics would increase the risk of death and developing cardiovascular disease. This suggests that clinicians should comprehensively consider the use of antithrombotics after peptic ulcer bleeding.
Kaneshiro, Bliss; Edelman, Alison; Carlson, Nichole E; Nichols, Mark; Forbes, Marci Messerle; Jensen, Jeffrey
2012-04-01
Unscheduled bleeding is the main side effect of continuous oral contraceptive pills (OCPs) and has been correlated with the up-regulation of matrix metalloprotineases (MMPs). The study objective was to determine if prophylactic administration of doxycycline (an MMP inhibitor at low subantimicrobial doses) would prevent unscheduled bleeding during the initiation of a continuous OCP. Subjects using cyclic hormonal contraceptives (combined OCPs, patch or ring) without unscheduled bleeding were switched to continuous OCPs (20 mcg ethinyl estradiol/100 mcg levonorgestrel). They were randomized to receive daily doxycycline [sustained-release subantimicrobial dose (40 mg daily)] or placebo for the first 84 days and then observed for an additional 28 days on the continuous OCP alone. The number of bleeding/spotting days and the time in days it took to achieve amenorrhea were compared using a t test. Sixty-five subjects were randomized. Although the use of doxycycline did not significantly decrease the number of mean bleeding/spotting days in the first 84 days of the study [doxycycline 14.75 (SE 2.30), placebo 17.78 (2.31), p=.36], women who received doxycycline had a significantly earlier onset of amenorrhea [mean last day of bleeding/spotting doxycycline 61.7 (7.7), placebo 85.2 (6.7), p=.03]. The coadministration of subantimicrobial-dose doxycycline during initiation of continuous OCPs results in a significant reduction in the length of time needed to achieve amenorrhea. Copyright © 2012 Elsevier Inc. All rights reserved.
Kaneshiro, Bliss; Edelman, Alison; Carlson, Nichole E.; Nichols, Mark; Forbes, Marci Messerle; Jensen, Jeffrey
2016-01-01
Background Unscheduled bleeding is the main side effect of continuous oral contraceptive pills (OCPs) and has been correlated with the up-regulation of matrix metalloprotineases (MMPs). The study objective was to determine if prophylactic administration of doxycycline (an MMP inhibitor at low subantimicrobial doses) would prevent unscheduled bleeding during the initiation of a continuous OCP. Study Design Subjects using cyclic hormonal contraceptives (combined OCPs, patch or ring) without unscheduled bleeding were switched to continuous OCPs (20 mcg ethinyl estradiol/100 mcg levonorgestrel). They were randomized to receive daily doxycycline [sustained-release subantimicrobial dose (40 mg daily)] or placebo for the first 84 days and then observed for an additional 28 days on the continuous OCP alone. The number of bleeding/spotting days and the time in days it took to achieve amenorrhea were compared using a t test. Results Sixty-five subjects were randomized. Although the use of doxycycline did not significantly decrease the number of mean bleeding/spotting days in the first 84 days of the study [doxycycline 14.75 (SE 2.30), placebo 17.78 (2.31), p=.36], women who received doxycycline had a significantly earlier onset of amenorrhea [mean last day of bleeding/spotting doxycycline 61.7 (7.7), placebo 85.2 (6.7), p=.03]. Conclusion The coadministration of subantimicrobial-dose doxycycline during initiation of continuous OCPs results in a significant reduction in the length of time needed to achieve amenorrhea. PMID:22067758
Analysis of fine coal pneumatic systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.
1987-01-01
Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less
Weisberg, Edith; Merki-Feld, Gabriele S; McGeechan, Kevin; Fraser, Ian S
2015-02-01
To compare bleeding patterns for 12 months continuous use of a contraceptive ring [contraceptive vaginal ring (CVR)] and pill [combined oral contraceptive (COC)] on a menstrually signaled regimen and the effectiveness of 4 days "treatment withdrawal" to stop bleeding. Women, 66 to each group, were randomized to continuous use of a CVR (15 mcg ethinyl estradiol/150 mcg etonogestrel) or a low-dose pill (20 mcg ethinyl estradiol/100 mcg levonorgestrel) for 360 days on a menstrually signaled regimen. Bleeding/spotting days, daily use of ring or pill, was recorded. Endpoint was the total number of bleeding/spotting days for each method over four 90-day reference periods (RP) plus the analysis of bleeding patterns using modified World Health Organization criteria. There was a reduction in the mean (±S.D.) number of bleeding/spotting days from RP1 (CVR 14.2±10; pill 16.6±10.9) to RP4 (CVR 8.8±9.6; pill 8.8±9.1). Fifteen percent of CVR and 4% COC users experienced amenorrhea or infrequent bleeding throughout the study. Amenorrhea increased over time (RP1 vs. RP4: CVR 10% vs. 21% and COC 2% vs. 30%). Compliance with the menstrually signaled regimen was poor. Ceasing hormones for 4 days stopped a bleeding episode within 5 days in the majority of episodes and many stopped spontaneously. Bleeding patterns with continuous use of the CVR and COC are similar and improve over 1 year of use. The unpredictability, but short duration, of bleeding episodes should be stressed during counseling. This information for clinicians and women about breakthrough bleeding patterns with use of a CVR or combined pill over 12 months using a menstrually signaled regimen will give women an indication of what to expect with continuous use. Copyright © 2015 Elsevier Inc. All rights reserved.
Reid, Robert L; Fortier, Michel P; Smith, Lynne; Mirkin, Sebastian; Grubb, Gary S; Constantine, Ginger D
2010-12-01
The study was conducted to evaluate bleeding profile and safety of continuous oral contraceptive (OC) containing levonorgestrel (LNG) 90 mcg/ethinyl estradiol (EE) 20 mcg. Healthy women who participated at seven Canadian sites in 1-year open-label study of LNG 90 mcg/EE 20 mcg daily were eligible for this second-year extension study. Primary end points included bleeding profile and adverse events. Seventy-nine women enrolled without interrupting pill taking; 62 (78.5%) completed. Adverse events were comparable to cyclic OC regimens, except unscheduled vaginal bleeding. Amenorrhea and absence of bleeding increased to about 80% and 90%, respectively, by Pill Pack 18. Mean (median) number of bleeding days for the last two 90-day intervals was 1.1 (0) and 0.7 (0) days, respectively. Continuous LNG 90 mcg/EE 20 mcg had a safety profile similar to low-dose cyclic OCs. Short-term safety profile remained excellent, with increasing rates of amenorrhea and decreasing incidence of unscheduled bleeding and/or spotting. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Scadron, Marvin D.
1952-01-01
A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy
Dynamic design and control of a high-speed pneumatic jet actuator
NASA Astrophysics Data System (ADS)
Misyurin, S. Yu; Ivlev, V. I.; Kreinin, G. V.
2017-12-01
Mathematical model of an actuator, consisting of a pneumatic (gas) high-speed jet engine, transfer mechanism, and a control device used for switching the ball valve is worked out. The specific attention was paid to the transition (normalization) of the dynamic model into the dimensionless form. Its dynamic simulation criteria are determined, and dynamics study of an actuator was carried out. The simple control algorithm of relay action with a velocity feedback enabling the valve plug to be turned with a smooth nonstop and continuous approach to the final position is demonstrated
Shah, Keyur B; Gunda, Sampath; Emani, Sitaramesh; Kanwar, Manreet K; Uriel, Nir; Colombo, Paolo C; Uber, Patricia A; Sears, Melissa L; Chuang, Joyce; Farrar, David J; Brophy, Donald F; Smallfield, George B
2017-11-01
Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. This multicenter, retrospective analysis evaluated 51 continuous-flow left ventricular assist device patients who received secondary prophylaxis with octreotide after their index GI bleed from 2009 to 2015. All patients had a hospitalization for GI bleed and received octreotide after discharge. Patient demographics, medical and medication history, and clinical characteristics of patients who rebled after receiving octreotide were compared with non-rebleeders. These data were also compared with matched historical control patients previously enrolled in the HMII (HeartMate II) clinical trials, none of whom received octreotide, to provide a context for the bleeding rates. Twelve patients (24%) who received secondary octreotide prophylaxis developed another GI bleed, whereas 39 (76%) did not. There were similar intergroup demographics; however, significantly more bleeders had a previous GI bleeding history before left ventricular assist device placement (33% versus 5%; P =0.02) and greater frequency of angiodysplasia confirmed during endoscopy (58% versus 23%; P =0.03). Fewer patients in this study experienced a recurrent GI bleed compared with a matched historical control group that did not receive octreotide (24% versus 43%; P =0.04). Patients with continuous-flow left ventricular assist device receiving secondary prophylaxis with octreotide had a significantly lower GI bleed recurrence compared with historical controls not treated with octreotide. Additional prospective studies are needed to confirm these data. © 2017 American Heart Association, Inc.
15 CFR 922.102 - Prohibited or otherwise regulated activities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND..., including such devices known as Hawaiian slings, pole spears, arbalettes, pneumatic and spring-loaded...
15 CFR 922.102 - Prohibited or otherwise regulated activities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND..., including such devices known as Hawaiian slings, pole spears, arbalettes, pneumatic and spring-loaded...
Bubble inductors: Pneumatic tuning of a stretchable inductor
NASA Astrophysics Data System (ADS)
Lazarus, Nathan; Bedair, Sarah S.
2018-05-01
From adaptive matching networks in power systems to channel selectable RF filters and circuitry, tunable inductors are fundamental components for circuits requiring reconfigurability. Here we demonstrate a new continuously tunable inductor based on physically stretching the inductor traces themselves. Liquid-metal-based stretchable conductors are wrapped around a pneumatic bubble actuator, allowing the inductor to be collapsed or expanded by application of pressure. In vacuum the bubble collapses, bringing the loop area to nearly zero, while positive pressure brings a dramatic increase in area and loop inductance. Using this approach, the inductor demonstrated in this work was able to achieve a tuning ratio of 2.6 with 1-2 second response time. With conductors available that can stretch by hundreds of percent, this technique is promising for very large tuning ratios in continuously tunable inductors.
Use of tranexamic acid in primary total knee replacement: effects on perioperative blood loss.
Volquind, Daniel; Zardo, Remi Antônio; Winkler, Bruno Costamilan; Londero, Bruno Bertagnolli; Zanelatto, Natália; Leichtweis, Gisele Perondi
2016-01-01
The use of tranexamic acid in primary total knee replacement surgeries has been the subject of constant study. The strategies to reduce bleeding are aimed at reducing the need for blood transfusion due to the risks involved. In this study we evaluated the use of tranexamic acid in reducing bleeding, need for blood transfusion, and prevalence of postoperative deep vein thrombosis in primary total knee replacement. 62 patients undergoing primary total knee replacement were enrolled in the study, from June 2012 to May 2013, and randomized to receive a single dose of 2.5g of intravenous tranexamic acid (Group TA) or saline (Group GP), 5min before opening the pneumatic tourniquet, respectively. Hemoglobin, hematocrit, and blood loss were recorded 24h after surgery. Deep vein thrombosis was investigated during patient's hospitalization and 15 and 30 days after surgery in review visits. There was no demographic difference between groups. Group TA had 13.89% decreased hematocrit (p=0.925) compared to placebo. Group TA had a decrease of 12.28% (p=0.898) in hemoglobin compared to Group GP. Group TA had a mean decrease of 187.35mL in blood loss (25.32%) compared to group GP (p=0.027). The number of blood transfusions was higher in Group GP (p=0.078). Thromboembolic events were not seen in this study. Tranexamic acid reduced postoperative bleeding without promoting thromboembolic events. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Efficacy of ankaferd blood stopper application on non-variceal upper gastrointestinal bleeding
Gungor, Gokhan; Goktepe, M Hakan; Biyik, Murat; Polat, Ilker; Tuna, Tuncer; Ataseven, Huseyin; Demir, Ali
2012-01-01
AIM: To prospectively assess the hemostatic efficacy of the endoscopic topical use of ankaferd blood stopper (ABS) in active non-variceal upper gastrointestinal system (GIS) bleeding. METHODS: Endoscopy was performed on 220 patients under suspiciency of GIS bleeding. Patients with active non-variceal upper gastrointestinal bleeding (NVUGIB) with a spurting or oozing type were included. Firstly, 8-10 cc of isotonic saline was sprayed to bleeding lesions. Then, 8 cc of ABS was applied on lesions in which bleeding continued after isotonic saline application. The other endoscopic therapeutic methods were applied on the lesions in which the bleeding did not stop after ABS. RESULTS: Twenty-seven patients had an active NVUGIB with a spurting or oozing type and 193 patients were excluded from the study since they did not have non-variceal active bleeding. 8 cc of ABS was sprayed on to the lesions of 26 patients whose bleeding continued after isotonic saline and in 19 of them, bleeding stopped after ABS. Other endoscopic treatment methods were applied to the remaining patients and the bleeding was stopped with these interventions in 6 of 7 patients. CONCLUSION: ABS is an effective method on NVUGIB, particularly on young patients with no coagulopathy. ABS may be considered as part of a combination treatment with other endoscopic methods. PMID:23293725
NASA Astrophysics Data System (ADS)
Kumarasubramanian, R.; Xavier, Goldwin; Nishanthi, W. Mary; Rajasekar, R.
2017-05-01
Considering the fuel crises today many work and research were conducted to reduce the fuel consumption of the internal combustion engine. The fuel consumption of an internal combustion engine can be relatively reduced by use of the electromagnetic clutch water pump and pneumatic compressor. Normally in an engine, the water pump is driven by the crankshaft, with an aid of belt, for the circulation of the water for the cooling process. The circulation of coolant is resisted by the thermostat valve, while the temperature inside the coolant jacket of the engine is below 375K the thermostat is closed only above 375K it tends to open. But water pump run continuously even when thermostat is closed. In pneumatic braking system, pneumatic or air compressor purpose is to compress the air and stored into the storage tank for the brake operation. When the air pressure of the storage tanks gets increases above its storage capacity pressure is regulated by governor, by passing them to atmosphere. Such unnecessary work of this water pump and air compressor can be minimized by use of the electromagnetic clutch water pump and air compressor. The European Driving Cycle is used to evaluate the performance of this water pump and air compressor when used in an engine. The result shows that the fuel economy of the engine while using electromagnetic water pump and pneumatic compressor were improved by 8.0% compared with conventional types which already exist. The application of these electromagnetic water pump and pneumatic compressor are expected to contribute for the improvement of engine performance because of their effect in reduction of the rate of fuel consumption.
An instrumented object for hand exercise and assessment using a pneumatic pressure sensor
NASA Astrophysics Data System (ADS)
Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.
2018-05-01
Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.
Choi, Hyuk; Lee, Heung-Man; Nam, Kyoung Won; Choi, Jaesoon; Lee, Jung-Joo; Kim, Ho Chul; Song, Seung Joon; Ahn, Chi Bum; Son, Ho Sung; Lim, Choon Hak; Son, Kuk Hui; Park, Yong Doo; Jeong, Gi Seok; Sun, Kyung
2011-06-01
In 2002, the paracorporeal pulsatile electro-mechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm). © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Standardizing a simpler, more sensitive and accurate tail bleeding assay in mice
Liu, Yang; Jennings, Nicole L; Dart, Anthony M; Du, Xiao-Jun
2012-01-01
AIM: To optimize the experimental protocols for a simple, sensitive and accurate bleeding assay. METHODS: Bleeding assay was performed in mice by tail tip amputation, immersing the tail in saline at 37 °C, continuously monitoring bleeding patterns and measuring bleeding volume from changes in the body weight. Sensitivity and extent of variation of bleeding time and bleeding volume were compared in mice treated with the P2Y receptor inhibitor prasugrel at various doses or in mice deficient of FcRγ, a signaling protein of the glycoprotein VI receptor. RESULTS: We described details of the bleeding assay with the aim of standardizing this commonly used assay. The bleeding assay detailed here was simple to operate and permitted continuous monitoring of bleeding pattern and detection of re-bleeding. We also reported a simple and accurate way of quantifying bleeding volume from changes in the body weight, which correlated well with chemical assay of hemoglobin levels (r2 = 0.990, P < 0.0001). We determined by tail bleeding assay the dose-effect relation of the anti-platelet drug prasugrel from 0.015 to 5 mg/kg. Our results showed that the correlation of bleeding time and volume was unsatisfactory and that compared with the bleeding time, bleeding volume was more sensitive in detecting a partial inhibition of platelet’s haemostatic activity (P < 0.01). Similarly, in mice with genetic disruption of FcRγ as a signaling molecule of P-selectin glycoprotein ligand-1 leading to platelet dysfunction, both increased bleeding volume and repeated bleeding pattern defined the phenotype of the knockout mice better than that of a prolonged bleeding time. CONCLUSION: Determination of bleeding pattern and bleeding volume, in addition to bleeding time, improved the sensitivity and accuracy of this assay, particularly when platelet function is partially inhibited. PMID:24520531
Nable, Jose V; Graham, Autumn C
2016-05-01
Acute gastrointestinal bleeding is a commonly encountered chief complaint with a high morbidity and mortality. The emergency physician is challenged with prompt diagnosis, accurate risk assessment, and appropriate resuscitation of patients with gastrointestinal bleeding. Goals of care aim to prevent end-organ injury, manage comorbid illnesses, identify the source of bleeding, stop continued bleeding, support oxygen carrying capacity, and prevent rebleeding. This article reviews current strategies for risk stratification, diagnostic modalities, localization of bleeding, transfusion strategies, adjunct therapies, and reversal of anticoagulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Hou, Melody Y; McNicholas, Colleen; Creinin, Mitchell D
2016-10-01
Estimate symptom improvement rate of women with bleeding complaints using the etonogestrel contraceptive implant when started on continuous combined oral contraceptives (COC). We conducted a double-blinded randomised controlled trial of women reporting troublesome bleeding related to their etonogestrel contraceptive implant and desiring intervention. Participants received continuous COCs or placebo for four weeks to evaluate self-reported bleeding improvement at four weeks. Participants could continue study treatment or prescribed COCs for another eight weeks if desired. We planned to enroll 130 participants between two sites (80% power to detect a 20% effect size at a 0.05 significance level, with 10% loss to follow up). We closed the study after enrolling 26 participants due to recruitment futility. All women on COCs and 75% of placebo users reported bleeding improvement at four weeks (p = 0.09), with 92% and 42%, respectively, reporting significant improvement (p = 0.03). The median number of days until bleeding stopped for at least four days in COC and placebo users was 1 day (range 1-9) and 4.5 days (range 1-28), respectively (p = 0.63). Eight (75%) COC and five (42%) placebo users opted to continue study treatment (p = 0.41). Despite bleeding improvement, women who desired implant removal at enrollment were more likely to re-request removal than those who initially considered other interventions (3 of 5 [60%] vs 1 of 17 [6%], p = 0.03). Although women who have troublesome bleeding while using the contraceptive implant may experience improvement with no treatment over 4 weeks, women using COCs are more likely to report significant improvement. Clinicaltrials.gov registration number: NCT01963403.
The Feasibility of Applying AC Driven Low-Temperature Plasma for Multi-Cycle Detonation Initiation
NASA Astrophysics Data System (ADS)
Zheng, Dianfeng
2016-11-01
Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating current (AC) driven low-temperature plasma using dielectric barrier discharge (DBD) is used for the combustion assistant. However, continuous AC driven plasmas cannot be used for ignition in pulse detonation engines. In this paper, experimental and numerical studies of pneumatic valve PDE using an AC driven low-temperature plasma igniter were described. The pneumatic valve was jointly designed with the low-temperature plasma igniter, and the numerical simulation of the cold-state flow field in the pneumatic valve showed that a complex flow in the discharge area, along with low speed, was beneficial for successful ignition. In the experiments ethylene was used as the fuel and air as oxidizing agent, ignition by an AC driven low-temperature plasma achieved multi-cycle intermittent detonation combustion on a PDE, the working frequency of the PDE reached 15 Hz and the peak pressure of the detonation wave was approximately 2.0 MPa. The experimental verifications of the feasibility in PDE ignition expanded the application field of AC driven low-temperature plasma. supported by National Natural Science Foundation of China (No. 51176001)
Abbas, Sascha; Ihle, Peter; Harder, Sebastian; Schubert, Ingrid
2014-05-05
There is major concern about coumarins interacting with various drug classes and increasing the risk of overanticoagulation. The aim of the study was to assess bleeding risk in patients with concurrent use of antibiotics and phenprocoumon, the most widely prescribed coumarin in many European countries. We conducted a nested-case-control study within a cohort of 513,338 incident and continuous phenprocoumon users ≥ 18 years of age using claims data of the statutory health insurance company AOK, covering 30% of the German population. Bleeding risk associated with current use of antibiotics for systemic use (antibacterials/antimycotics) was calculated using conditional logistic regression in 13,785 cases with a bleeding event and 55,140 risk-set sampling-matched controls. Bleeding risk associated with any antibacterial use in phenprocoumon users was significantly increased [odds ratio (OR) 2.37, 95% confidence interval (CI) 2.20-2.56]. The association was stronger for gastrointestinal than for cerebral bleeding (OR 2.09, 95% CI 1.84-2.38 and OR 1.34, 95% CI 1.03-1.74, respectively) and highest for other/unspecified bleeding (OR 2.92, 95% CI 2.62-3.26). Specific antibiotic classes were strongly associated with bleeding risk, e.g. cotrimoxazole (OR 3.86, 95% CI 3.08-4.84) and fluorquinolones (OR 3.13, 95% CI 2.74-3.59), among those highest for ofloxacin (OR 5.00, 95% CI 3.01-8.32). Combined use of phenprocoumon and antimycotics was not significantly associated with bleeding risk. Risk was not significantly modified by age (pint=0.25) or sex (pint=0.96). The association was stronger the closer the antibiotic exposure was to the bleeding event. Among continuous phenprocoumon users, antibiotics - particularly quinolones and cotrimoxazole - should be prescribed after careful consideration due to an increased bleeding risk. Close monitoring of international normalised ratio levels after prescription is recommended.
Evaluation of a continuous regimen of levonorgestrel/ethinyl estradiol: phase 3 study results.
Archer, David F; Jensen, Jeffrey T; Johnson, Julia V; Borisute, Hannah; Grubb, Gary S; Constantine, Ginger D
2006-12-01
This study was conducted to evaluate the safety and efficacy of a continuous daily regimen of levonorgestrel (LNG) 90 microg/ethinyl estradiol (EE) 20 microg (continuous LNG/EE). Healthy women aged 18-49 years with regular menstrual cycles for 3 months enrolled in this single-treatment open-label study and took one pill of LNG 90 microg/EE 20 microg daily for 12 months. For the 2134 subjects enrolled, the Pearl Index method failure was 1.26, and user failure was 0.34. While on Pill Pack 13, 58.7% of subjects reported amenorrhea and 79.0% reported absence of bleeding. Overall, the number of bleeding and spotting days per pill pack declined progressively. Adverse events and discontinuations were comparable to those reported for cyclic oral contraceptive (OC) regimens, except for higher rates in those related to uterine bleeding. Continuous LNG/EE demonstrated a good safety profile and efficacy similar to cyclic OCs. The regimen continuously inhibited menses, increased the incidence of amenorrhea over time and, except for a subset of women, decreased the number of bleeding and spotting days.
Safety of continuing aspirin therapy during spinal surgery: A systematic review and meta-analysis.
Zhang, Chenggui; Wang, Guodong; Liu, Xiaoyang; Li, Yang; Sun, Jianmin
2017-11-01
Questions whether to continue or discontinue aspirin administration in the perioperative period of spinal surgery has not been systematically evaluated. The present systematic review is carried out to assess the impact of continuing aspirin administration on the bleeding and cardiovascular events in perispinal surgery period. Studies were retrieved through MEDLINE, EMBASE, and Springer Link Databases (search terms, aspirin, continue or discontinue, and spinal fusion), bibliographies of the articles retrieved, and the authors' reference files. We included studies that enrolled patients who underwent spinal surgery who were anticoagulated with aspirin alone and that reported bleeding or cardiovascular events as an outcome. Study quality was assessed using a validated form. 95% confidence interval (95% CI) was pooled to give summary estimates of bleeding and cardiovascular risk. We identified 4 studies assessing bleeding risk associated with aspirin continuation or cardiovascular risk with aspirin discontinuation during spinal surgery. The continuation of aspirin will not increase the risk of blood loss during the spinal surgery (95% CI, -111.72 to -0.59; P = .05). Also, there was no observed increase in the operative time (95% CI, -33.29 to -3.89; P = .01) and postoperative blood transfusion (95% CI, 0.00-0.27; P = .05). But as for the cardiovascular risk without aspirin continuation and mean hospital length of stay with aspirin continuation, we did not get enough samples to make an accurate decision about their relations with aspirin. Patients undergoing spinal surgery with continued aspirin administration do not have an increased risk for bleeding. In addition, there is no observed increase in the operation time and postoperative blood transfusion.
Teichmann, Alexander; Apter, Dan; Emerich, Janusz; Greven, Klaus; Klasa-Mazurkiewicz, Dagmara; Melis, Giambi B; Spaczynski, Marek; Grubb, Gary S; Constantine, Ginger D; Spielmann, Daniele
2009-12-01
This Phase 3, randomized, open-label, multicenter study conducted at 44 sites in Europe evaluated the safety and efficacy of a continuous, daily regimen of levonorgestrel (LNG) 90 mcg/ethinyl estradiol (EE) 20 mcg compared with a 21-day, cyclic LNG 100 mcg/EE 20 mcg regimen. Three hundred twenty-three healthy women were randomized to continuous LNG 90 mcg/EE 20 mcg and 318 subjects to cyclic LNG 100 mcg/EE 20 mcg for 1 year (13 pill packs). Pearl index, adverse event (AE) incidence and bleeding profiles were assessed. No pregnancies occurred with the continuous oral contraceptive (OC) (Pearl index=0.00). As the study progressed, the percentage of women who achieved amenorrhea during each 28-day pill pack increased: 40% at pill pack 7, 53% at pill pack 13. The percentage of women with no bleeding [with or without spotting (defined as not requiring sanitary protection)] was 50%, 69% and 79% at pill packs 3, 7 and 13, respectively. The incidence of AEs was similar to that of the cyclic OC (except for metrorrhagia and vaginal bleeding in the first 6 months). Continuous LNG 90 mcg/EE 20 mcg was shown to be a safe and effective OC in this direct comparison to a cyclic OC. Suppression of menses and the potential for no bleeding requiring sanitary protection may be provided by this continuous, low-dose OC.
3D CBCT anatomy of the pterygopalatine fossa.
Rusu, Mugurel Constantin; Didilescu, Andreea Cristiana; Jianu, Adelina Maria; Păduraru, Dumitru
2013-03-01
The anatomy of the pterygopalatine fossa keeps a traditional level and is viewed as constant, even though a series of structures neighboring the fossa are known to present individual variations. We aimed to evaluate on 3D volume renderizations the anatomical variables of the pterygopalatine fossa, as related to the variable pneumatization patterns of the bones surrounding the fossa. The study was performed retrospectively on cone beam computed tomography (CBCT) scans of 100 patients. The pterygopalatine fossa was divided into an upper (orbital) and a lower (pterygomaxillary) floor; the medial compartment of the orbital floor lodges the pterygopalatine ganglion. The pneumatization patterns of the pterygopalatine fossa orbital floor walls were variable: (a) the posterior wall pneumatization pattern was determined in 89.5 % by recesses of the sphenoidal sinus related to the maxillary nerve and pterygoid canals; (b) the upper continuation of the pterygopalatine fossa with the orbital apex was narrowed in 79.5 % by ethmoid air cells and/or a maxillary recess of the sphenoidal sinus; (c) according to its pneumatization pattern, the anterior wall of the pterygopalatine fossa was a maxillary (40.5 %), maxillo-ethmoidal (46.5 %), or maxillo-sphenoidal (13 %) wall. The logistic regression models showed that the maxillo-ethmoidal type of pterygopalatine fossa anterior wall was significantly associated with a sphenoidal sinus only expanded above the pterygoid canal and a spheno-ethmoidal upper wall. The pterygopalatine fossa viewed as an intersinus space is related to variable pneumatization patterns which can be accurately identified by CBCT and 3DVR studies, for anatomic and preoperatory purposes.
40 CFR 428.11 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AND STANDARDS (CONTINUED) RUBBER MANUFACTURING POINT SOURCE CATEGORY Tire and Inner Tube Plants... black, oils, chemical compounds, fabric and wire used in the manufacture of pneumatic tires and inner... inner tube plants constructed before 1959, discharges from the following: Soapstone solution...
40 CFR 428.11 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND STANDARDS (CONTINUED) RUBBER MANUFACTURING POINT SOURCE CATEGORY Tire and Inner Tube Plants... black, oils, chemical compounds, fabric and wire used in the manufacture of pneumatic tires and inner... inner tube plants constructed before 1959, discharges from the following: Soapstone solution...
[Gastrointestinal bleeding in the elderly].
Glaser, J
2014-08-01
Peptic ulcer disease is a common cause of gastrointestinal bleeding, independent of the patient's age. With advancing age, an increase of lower gastrointestinal bleeding (diverticula, angiodysplasia) has been observed. The administration of non-steroidal anti-inflammatory drugs and aspirin is an important risk factor for upper and lower gastrointestinal bleeding, thus in patients aged 65 years and more a concomitant therapy with proton pump inhibitors is recommended in order to prevent ulcer bleeding. Even in very old individuals endoscopy should be used for the diagnosis of gastrointestinal bleeding, providing the opportunity for definite endoscopic bleeding therapy. In elderly patients with comorbidities and recurrent bleeding after endoscopic therapy or continuous blood loss, surgery or transarterial embolisation should be considered in good time. Georg Thieme Verlag KG Stuttgart · New York.
Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.
2015-01-01
Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird-line archosaurs. Beyond providing a comprehensive view of vertebral pneumaticity in a non-avian coelurosaur, this study demonstrates the utility and need of CT imaging for further clarifying the early evolutionary history of postcranial pneumaticity. PMID:26682888
Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Hong, Joung Boom; Park, Su Bum; Kim, Su Jin; Cho, Mong
2015-07-01
A high dose of continuous intravenous infusion of proton pump inhibitor (PPI) is the standard treatment for peptic ulcer bleeding. The optimal dose for the prevention of bleeding after endoscopic submucosal dissection (ESD) is unclear. The purpose of this study was to determine whether stronger acid suppression more effectively prevents bleeding and high risk ulcer stigma (HRS) after gastric ESD. A total of 273 patients who underwent ESD were randomly assigned to one of two treatment groups: the continuous infusion group and the bolus injection group. Second-look endoscopy was performed on the following day after ESD. The incidences and risk factors of HRS identified by second-look endoscopy and delayed bleeding were analyzed. There were no differences in the incidences of HRS and delayed bleeding between two treatment groups. The incidence of HRS was 15.8 % (43/273) and the gross morphology (flat or depressed) was identified as a significant factor associated with HRS. The incidence of delayed bleeding was 8.4 % (23/273) and the gross morphology (flat) and the presence of submucosal invasive cancer were identified as the associated risk factors for delayed bleeding. The incidences of delayed bleeding and HRS identified by second-look endoscopy were not affected by PPI infusion methods. Flat or depressed morphologic lesions and submucosal invasive cancer should be closely monitored.
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
21 CFR 864.6100 - Bleeding time device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...
Kakizawa, Hideaki; Toyota, Naoyuki; Mita, Koji; Fujimura, Yoshio; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Ito, Katsuhide
2006-05-01
We report a case that was successfully treated for massive lower gastrointestinal (LGI) bleeding due to a recurrent urinary bladder carcinoma. Treatment consisted of combination therapy including embolization of an inferior gluteal artery (IGA) pseudoaneurysm and low-dose arterial vasopressin infusion via a sigmoid artery (SA). A 57-year-old man presented with life-threatening sudden, massive LGI bleeding due to an obturator lymph node (LN) metastasis from a urinary bladder carcinoma. Computed tomography showed that the LN recurrence had invaded all the way to the sigmoid colon, and there was a pseudoaneurysm with extravasation inside the recurrence. An angiogram revealed a left IGA pseudoaneurysm. We therefore excluded the pseudoaneurysm by embolization with microcoils. Following this treatment the bleeding decreased, but intermittent LGI bleeding continued. Endoscopic examination showed the tumor with a huge ulcer inside the colonic lumen, and continuous oozing was confirmed. A second angiogram showed no recurrence of the IGA pseudoaneurysm and no apparent findings of bleeding. Then a 3F microcatheter was placed in the SA selectively using a coaxial catheter system, and vasopressin was infused at a rate 0.05 U/min for 12 h. Bleeding completely ceased 2 days later. There were no signs of ischemic gastrointestinal complications. Massive LGI bleeding has not recurred in 5 months.
Sliding pressure control valve for pneumatic hammer drill
Polsky, Yarom [Albuquerque, NM
2011-08-30
A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.
49 CFR 236.739 - Device, acknowledging.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Device, acknowledging. 236.739 Section 236.739 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Device, acknowledging. A manually operated electric switch or pneumatic valve by means of which, on a...
Nappi, Rossella E; Lobo Abascal, Paloma; Hsieh, Jennifer; Micheletti, Marie-Christine
2017-01-01
To evaluate scheduled and unscheduled bleeding and spotting over 1 year of treatment with 91-day extended-regimen combined oral contraception (COC) providing continuous low-dose ethinyl estradiol (EE) in place of the traditional 7-day hormone-free interval (HFI). This post hoc analysis of a multicenter, open-label, 1-year, Phase 3 study of extended-regimen COC with 30 µg EE/150 µg levonorgestrel (LNG) for 84 days and EE 10 µg for 7 days included 799 sexually active, adult women who completed at least one 91-day cycle of therapy. Subjects recorded bleeding and spotting episodes daily using electronic diaries. Logistic regression analyses are reported as ORs with 95% CIs. There was a 10% increase (OR =1.102; 95% CI: 1.006-1.206) in the likelihood of reporting no scheduled bleeding for each additional 91-day cycle completed. From the third 91-day cycle, more than one fifth of women reported no scheduled bleeding (third cycle =23% [121/533]; fourth cycle =22% [97/446]). Among women who reported no scheduled bleeding at Cycle 1 (136/758 [18%]), ≥45% showed sustained lack of scheduled bleeding in later cycles. There were increases of 53% (OR =1.531; 95% CI: 1.393-1.683) and 31% (OR =1.307; 95% CI: 1.205-1.418) in the likelihood of reporting 0 to ≤6 days vs >6 days of unscheduled bleeding and spotting, respectively, for each additional 91-day cycle. By Cycle 2, more than 80% of women reported no unscheduled bleeding or ≤6 days of unscheduled bleeding during each 91-day cycle. Improved cycle control with decreased bleeding over time was shown during extended-regimen COC with 30 µg EE/150 µg LNG for 84 days and continuous low-dose EE instead of the traditional 7-day HFI. Women considering this regimen should be informed that those who complete at least one 91-day COC cycle will likely experience less bleeding/spotting in future cycles.
Nappi, Rossella E; Lobo Abascal, Paloma; Hsieh, Jennifer; Micheletti, Marie-Christine
2017-01-01
Purpose To evaluate scheduled and unscheduled bleeding and spotting over 1 year of treatment with 91-day extended-regimen combined oral contraception (COC) providing continuous low-dose ethinyl estradiol (EE) in place of the traditional 7-day hormone-free interval (HFI). Patients and methods This post hoc analysis of a multicenter, open-label, 1-year, Phase 3 study of extended-regimen COC with 30 µg EE/150 µg levonorgestrel (LNG) for 84 days and EE 10 µg for 7 days included 799 sexually active, adult women who completed at least one 91-day cycle of therapy. Subjects recorded bleeding and spotting episodes daily using electronic diaries. Logistic regression analyses are reported as ORs with 95% CIs. Results There was a 10% increase (OR =1.102; 95% CI: 1.006–1.206) in the likelihood of reporting no scheduled bleeding for each additional 91-day cycle completed. From the third 91-day cycle, more than one fifth of women reported no scheduled bleeding (third cycle =23% [121/533]; fourth cycle =22% [97/446]). Among women who reported no scheduled bleeding at Cycle 1 (136/758 [18%]), ≥45% showed sustained lack of scheduled bleeding in later cycles. There were increases of 53% (OR =1.531; 95% CI: 1.393–1.683) and 31% (OR =1.307; 95% CI: 1.205–1.418) in the likelihood of reporting 0 to ≤6 days vs >6 days of unscheduled bleeding and spotting, respectively, for each additional 91-day cycle. By Cycle 2, more than 80% of women reported no unscheduled bleeding or ≤6 days of unscheduled bleeding during each 91-day cycle. Conclusion Improved cycle control with decreased bleeding over time was shown during extended-regimen COC with 30 µg EE/150 µg LNG for 84 days and continuous low-dose EE instead of the traditional 7-day HFI. Women considering this regimen should be informed that those who complete at least one 91-day COC cycle will likely experience less bleeding/spotting in future cycles. PMID:29042818
Eijgenraam, Pieter; ten Cate, Hugo; Ten Cate-Hoek, Arina
2013-01-01
Surgical interventions in patients on long term vitamin K antagonist (VKA) treatment create a dilemma; periprocedural interruption of anticoagulation raises the risk of thrombosis, while continuation raises the risk of bleeding. The anticoagulation- free interval is minimized by "bridging" with parenteral anticoagulants. The efficacy and safety of bridging with low molecular weight heparins (LMWH) has however not been unequivocally established. We performed an EMBASE and MEDLINE search for studies that compared bridging anticoagulation with continuation or cessation of VKA without bridging; with thromboembolism (TE) and bleeding as outcomes. We identified 878 articles and finally selected 17. Results of individual studies were pooled. None of the included studies reported significant differences in incidence of TEs between the bridging group and the comparator group; 4 out of 13 studies reported zero TEs. Heparin was identified as a risk factor for bleeding in multivariable adjusted analyses in 3 studies on pacemaker/implantable cardioverter defibrillator (PM/ICD) surgery. In 5 studies (different types of surgery) with unadjusted analyses, bridging was compared to warfarin cessation: 3 studies reported null results for bleeding; 2 studies identified bridging as a risk factor. We pooled a subset of 6 studies regarding postoperative bleeding after PM/ICD surgery and found a relative risk (RR) of 3.03 (95% confidence interval (CI), 1.86-4.95) for bridging compared to continuation of VKA. While the antithrombotic efficacy of bridging with LMWH has not been demonstrated, increased bleeding risk is observed in different types of surgery. PM/ICD surgery can be safely performed on continued VKA.
Coal-fluid properties with an emphasis on dense phase. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klinzing, G.E.
1985-04-01
Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC), equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors and Micro Motion Mass Flow Meters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana Rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius and pipe bends. In this report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less
NASA Astrophysics Data System (ADS)
Gouge, M. J.; Combs, S. K.; Foust, C. R.; Milora, S. L.
Advanced plasma fueling systems for magnetic fusion confinement experiments are under development at Oak Ridge National Laboratory (ORNL). The general approach is that of producing and accelerating frozen hydrogenic pellets to speeds in the kilometer-per-second range using single shot and repetitive pneumatic (light-gas gun) pellet injectors. The millimeter-to-centimeter size pellets enter the plasma and continuously ablate because of the plasma electron heat flux, depositing fuel atoms along the pellet trajectory. This fueling method allows direct fueling in the interior of the hot plasma and is more efficient than the alternative method of injecting room temperature fuel gas at the wall of the plasma vacuum chamber. Single-stage pneumatic injectors based on the light-gas gun concept have provided hydrogenic fuel pellets in the speed range of 1 to 2 km/s in single-shot injector designs. Repetition rates up to 5 Hz have been demonstrated in repetitive injector designs. Future fusion reactor-scale devices may need higher pellet velocities because of the larger plasma size and higher plasma temperatures. Repetitive two-stage pneumatic injectors are under development at ORNL to provide long-pulse plasma fueling in the 3 to 5 km/s speed range. Recently, a repeating, two-stage light-gas gun achieved repetitive operation at 1 Hz with speeds in the range of 2 to 3 km/s.
NASA Technical Reports Server (NTRS)
Englar, Robert J.
1998-01-01
Personnel of the Georgia Tech Research Institute (GTRI) Aerospace and Transportation Lab have completed a four-year grant program to develop and evaluate the pneumatic aerodynamic technology known as Circulation Control (CC) or Circulation Control Wing (CCW) for advanced transport aircraft. This pneumatic technology, which employs low-level blowing from tangential slots over round or near-round trailing edges of airfoils, greatly augments the circulation around a lifting or control surface and thus enhances the aerodynamic forces and moments generated by that surface. Two-dimensional force augmentations as high as 80 times the input blowing momentum coefficient have been recorded experimentally for these blown devices, thus providing returns of 8000% on the jet momentum expended. A further benefit is the absence of moving parts such as mechanical flaps, slats, spoilers, ailerons, elevators and rudders from these pneumatic surfaces, or the use of only very small, simple, blown aerodynamic surfaces on synergistic designs which integrate the lift, drag and control surfaces. The application of these devices to advanced aircraft can offer significant benefits in their performance, efficiency, simplicity, reliability, economic cost of operation, noise reduction, and safety of flight. To further develop and evaluate this potential, this research effort was conducted by GTRI under grant for the NASA Langley Research Center, Applied Aerodynamics Division, Subsonic Aerodynamics Branch, between June 14, 1993 and May 31, 1997.
Static and dynamic stability of pneumatic vibration isolators and systems of isolators
NASA Astrophysics Data System (ADS)
Ryaboy, Vyacheslav M.
2014-01-01
Pneumatic vibration isolation is the most widespread effective method for creating vibration-free environments that are vital for precise experiments and manufacturing operations in optoelectronics, life sciences, microelectronics, nanotechnology and other areas. The modeling and design principles of a dual-chamber pneumatic vibration isolator, basically established a few decades ago, continue to attract attention of researchers. On the other hand, behavior of systems of such isolators was never explained in the literature in sufficient detail. This paper covers a range of questions essential for understanding the mechanics of pneumatic isolation systems from both design and application perspectives. The theory and a model of a single standalone isolator are presented in concise form necessary for subsequent analysis. Then the dynamics of a system of isolators supporting a payload is considered with main attention directed to two aspects of their behavior: first, the static stability of payloads with high positions of the center of gravity; second, dynamic stability of the feedback system formed by mechanical leveling valves. The direct method of calculating the maximum stable position of the center of gravity is presented and illustrated by three-dimensional stability domains; analytic formulas are given that delineate these domains. A numerical method for feedback stability analysis of self-leveling valve systems is given, and the results are compared with the analytical estimates for a single isolator. The relation between the static and dynamic phenomena is discussed.
A new pneumatic suspension system with independent stiffness and ride height tuning capabilities
NASA Astrophysics Data System (ADS)
Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui
2012-12-01
This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.
Characterization of a hydro-pneumatic suspension strut with gas-oil emulsion
NASA Astrophysics Data System (ADS)
Yin, Yuming; Rakheja, Subhash; Yang, Jue; Boileau, Paul-Emile
2018-06-01
The nonlinear stiffness and damping properties of a simple and low-cost design of a hydro-pneumatic suspension (HPS) strut that permits entrapment of gas into the hydraulic oil are characterized experimentally and analytically. The formulation of gas-oil emulsion is studied in the laboratory, and the variations in the bulk modulus and mass density of the emulsion are formulated as a function of the gas volume fraction. An analytical model of the HPS is formulated considering polytropic change in the gas state, seal friction, and the gas-oil emulsion flows through orifices and valves. The model is formulated considering one and two bleed orifices configurations of the strut. The measured data acquired under a nearly constant temperature are used to identify gas volume fraction of the emulsion, and friction and flow discharge coefficients as functions of the strut velocity and fluid pressure. The results suggested that single orifice configuration, owing to high fluid pressure, causes greater gas entrapment within the oil and thus significantly higher compressibility of the gas-oil emulsion. The model results obtained under different excitations in the 0.1-8 Hz frequency range showed reasonably good agreements with the measured stiffness and damping properties of the HPS strut. The results show that the variations in fluid compressibility and free gas volume cause increase in effective stiffness but considerable reduction in the damping in a highly nonlinear manner. Increasing the gas volume fraction resulted in substantial hysteresis in the force-deflection and force-velocity characteristics of the strut.
Shoji, Takuhiro; Kawaguchi, Tomohiro; Ogawa, Yoshikazu; Watanabe, Mika; Fujimura, Miki; Tominaga, Teiji
2018-06-05
Nonobstructive hydrocephalus in patients with craniopharyngiomas is uncommon. We describe our surgical series of 25 consecutive patients with craniopharyngioma who presented with hydrocephalus. Obstructive hydrocephalus was evident in most cases, and nonobstructive hydrocephalus was revealed in three cases. Even after improvement of cerebrospinal fluid (CSF) pathway obstruction by tumor removal, 10 patients (40%) required CSF diversion. Preoperative imaging study revealed thin intraventricular hemorrhage or superficial siderosis in five cases, and CSF examination revealed hemosiderin-laden phagocytes in one case. These findings indicate continuous bleeding into the CSF that might be associated with CSF malabsorption. We also describe a representative case of craniopharyngioma associated with nonobstructive hydrocephalus due to continuous minor bleeding from the tumor surface in a 62-year-old man with a complaint of disorientation and a decline in daily living activity.Our study demonstrated that minor bleeding into the CSF is a possible mechanism of the development of nonobstructive hydrocephalus in patients with craniopharyngiomas. Georg Thieme Verlag KG Stuttgart · New York.
Adding the 'heart' to hanging drop networks for microphysiological multi-tissue experiments.
Rismani Yazdi, Saeed; Shadmani, Amir; Bürgel, Sebastian C; Misun, Patrick M; Hierlemann, Andreas; Frey, Olivier
2015-11-07
Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid-air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip.
Twin-Screw Extruder and Pellet Accelerator Integration Developments for ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk
The ITER pellet injection system consisting of a twinscrew frozen hydrogen isotope extruder, coupled to a combination solenoid actuated pellet cutter and pneumatic pellet accelerator, is under development at the Oak Ridge National Laboratory. A prototype extruder has been built to produce a continuous solid deuterium extrusion and will be integrated with a secondary section, where pellets are cut, chambered, and launched with a single-stage pneumatic accelerator into the plasma through a guide tube. This integrated pellet injection system is designed to provide 5 mm fueling pellets, injected at a rate up to 10 Hz, or 3 mm edge localizedmore » mode (ELM) triggering pellets, injected at higher rates up to 20 Hz. The pellet cutter, chamber mechanism, and the solenoid operated pneumatic valve for the accelerator are optimized to provide pellet velocities between 200-300 m/s to ensure high pellet survivability while traversing the inner wall fueling guide tubes, and outer wall ELMpacing guide tubes. This paper outlines the current twin-screwextruder design, pellet accelerator design, and the integrationrequired for both fueling and ELM pacing pellets.« less
Pneumatic Valve Operated by Multiplex Pneumatic Transmission
NASA Astrophysics Data System (ADS)
Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi
A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.
29 CFR 1910.67 - Vehicle-mounted elevating and rotating work platforms.
Code of Federal Regulations, 2012 CFR
2012-07-01
....67 Section 1910.67 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Powered Platforms, Manlifts, and...) Bursting safety factor. All critical hydraulic and pneumatic components shall comply with the provisions of...
Heikinheimo, O; Inki, P; Schmelter, T; Gemzell-Danielsson, K
2014-06-01
What is the bleeding pattern during second consecutive levonorgestrel-releasing intrauterine system (LNG-IUS) use? Consecutive use of LNG-IUS is associated with a predictable bleeding pattern, characterized by the absence of the initial period of irregular bleeding seen after interval insertion of an LNG-IUS and a non-bleeding pattern in the vast majority of women. With increased popularity of the LNG-IUS for long-term birth control and treatment of heavy menstrual bleeding (HMB), consecutive use of the system is becoming more frequent. One previous study showed 60% amenorrhea rate in consecutive IUS users; however, the sample size was small. A prospective multicenter study in four European countries recruited women who wished to continue with LNG-IUS use immediately after the first 5-year period. A total of 204 women were followed up until the end of the first year of the second IUS. Thereafter 170 women continued into the extension phase of the study up to the full 5 years of use of the second IUS and 144 women continued to the end of the study. A total of 170 women (mean age 39 years) who had been using their first LNG-IUS for between 4 years 3 months and 4 years 9 months, either for contraception or for treatment of HMB, and who planned to replace the device with a new LNG-IUS, were recruited and followed up to 5 years of the second IUS use. A total of 17 centers in four European countries were involved in the study. Bleeding patterns were analyzed using daily bleeding diaries using 90-day reference periods (RP) for the first year of the second IUS use and for the last RP of each year during Years 2-5 of use. Approximately 70% of women were free of bleeding during Years 2-5 and up to 49% were amenorrheic. There was a slight increase in the number of bleeding/spotting days of ∼3 days during the first RP immediately after the placement of the second IUS, whereafter the number of bleeding/spotting days returned to the level preceding the second IUS insertion or below that. Absence of bleeding was associated with high overall satisfaction and continuation rates. No serious adverse events assessed as related to the LNG-IUS use occurred during the 5-year period. The cumulative expulsion rate during the 5-year study period was 1.2%. The sample size was large enough to study bleeding patterns, and subjects are likely to represent typical consecutive IUS users, and therefore, the role of chance is small. The women represent a selected group as they had already successfully used their first IUS for almost 5 years and were willing to continue its use-however, this is currently a common clinical situation. The results may therefore not be extrapolated to first-time users of the LNG-IUS. These data are of importance when counseling women who are making decisions concerning long-term contraception. This study was funded by Bayer Pharma AG. P.I. and T.S. are full-time employees of Bayer Pharma AG. O.H. and K. G-D. have received consultancy fees from Bayer Pharma AG. The publication was developed jointly by all authors without third-party involvement and no honoraria were paid for any authors for their contribution to this manuscript. NCT00393198.
NASA Electric Aircraft Test Bed (NEAT) Development Plan - Design, Fabrication, Installation
NASA Technical Reports Server (NTRS)
Dyson, Rodger W.
2016-01-01
As large airline companies compete to reduce emissions, fuel, noise, and maintenance costs, it is expected that more of their aircraft systems will shift from using turbofan propulsion, pneumatic bleed power, and hydraulic actuation, to instead using electrical motor propulsion, generator power, and electrical actuation. This requires new flight-weight and flight-efficient powertrain components, fault tolerant power management, and electromagnetic interference mitigation technologies. Moreover, initial studies indicate some combination of ambient and cryogenic thermal management and relatively high bus voltages when compared to state of practice will be required to achieve a net system benefit. Developing all these powertrain technologies within a realistic aircraft architectural geometry and under realistic operational conditions requires a unique electric aircraft testbed. This report will summarize existing testbed capabilities located in the U.S. and details the development of a unique complementary testbed that industry and government can utilize to further mature electric aircraft technologies.
Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles
NASA Astrophysics Data System (ADS)
Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng
2017-09-01
Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.
1988-01-01
Presented is a mathematical model derived from the Navier-Stokes equations of momentum and continuity, which may be accurately used to predict the behavior of conventionally mounted pneumatic sensing systems subject to arbitrary pressure inputs. Numerical techniques for solving the general model are developed. Both step and frequency response lab tests were performed. These data are compared with solutions of the mathematical model and show excellent agreement. The procedures used to obtain the lab data are described. In-flight step and frequency response data were obtained. Comparisons with numerical solutions of the math model show good agreement. Procedures used to obtain the flight data are described. Difficulties encountered with obtaining the flight data are discussed.
NASA Technical Reports Server (NTRS)
Kazin, S. B.; Minzner, W. R.; Paas, J. E.
1971-01-01
A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a rotor tip casing bleed slot to determine its effects on noise generation. The bleed slot was located 1/2 inch (1.3 cm) upstream of the rotor leading edge and was configured to be a continuous opening around the circumference. The bleed manifold system was operated over a range of bleed rates corresponding to as much as 6% of the fan flow at approach thrust and 4.25% of the fan flow at takeoff thrust. Acoustic results indicate that a bleed rate of 4% of the fan flow reduces the fan maximum approach 200 foot (61.0 m) sideline PNL 0.5 PNdB and the corresponding takeoff thrust noise 1.1 PNdB below the level with zero bleed. However, comparison of the standard casing (no bleed slot) and the slotted bleed casing with zero bleed shows that the bleed slot itself caused a noise increase.
Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo
2016-04-01
This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.
Prevention of VTE in Nonorthopedic Surgical Patients
Garcia, David A.; Wren, Sherry M.; Karanicolas, Paul J.; Arcelus, Juan I.; Heit, John A.; Samama, Charles M.
2012-01-01
Background: VTE is a common cause of preventable death in surgical patients. Methods: We developed recommendations for thromboprophylaxis in nonorthopedic surgical patients by using systematic methods as described in Methodology for the Development of Antithrombotic Therapy and Prevention of Thrombosis Guidelines. Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines in this supplement. Results: We describe several alternatives for stratifying the risk of VTE in general and abdominal-pelvic surgical patients. When the risk for VTE is very low (< 0.5%), we recommend that no specific pharmacologic (Grade 1B) or mechanical (Grade 2C) prophylaxis be used other than early ambulation. For patients at low risk for VTE (∼1.5%), we suggest mechanical prophylaxis, preferably with intermittent pneumatic compression (IPC), over no prophylaxis (Grade 2C). For patients at moderate risk for VTE (∼3%) who are not at high risk for major bleeding complications, we suggest low-molecular-weight heparin (LMWH) (Grade 2B), low-dose unfractionated heparin (Grade 2B), or mechanical prophylaxis with IPC (Grade 2C) over no prophylaxis. For patients at high risk for VTE (∼6%) who are not at high risk for major bleeding complications, we recommend pharmacologic prophylaxis with LMWH (Grade 1B) or low-dose unfractionated heparin (Grade 1B) over no prophylaxis. In these patients, we suggest adding mechanical prophylaxis with elastic stockings or IPC to pharmacologic prophylaxis (Grade 2C). For patients at high risk for VTE undergoing abdominal or pelvic surgery for cancer, we recommend extended-duration, postoperative, pharmacologic prophylaxis (4 weeks) with LMWH over limited-duration prophylaxis (Grade 1B). For patients at moderate to high risk for VTE who are at high risk for major bleeding complications or those in whom the consequences of bleeding are believed to be particularly severe, we suggest use of mechanical prophylaxis, preferably with IPC, over no prophylaxis until the risk of bleeding diminishes and pharmacologic prophylaxis may be initiated (Grade 2C). For patients in all risk groups, we suggest that an inferior vena cava filter not be used for primary VTE prevention (Grade 2C) and that surveillance with venous compression ultrasonography should not be performed (Grade 2C). We developed similar recommendations for other nonorthopedic surgical populations. Conclusions: Optimal thromboprophylaxis in nonorthopedic surgical patients will consider the risks of VTE and bleeding complications as well as the values and preferences of individual patients. PMID:22315263
PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION
In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...
Mungan, Zeynel
2012-01-01
This observational, retrospective cohort study assessed outcomes of the current management strategies for nonvariceal upper gastrointestinal bleeding in several European countries (Belgium, Greece, Italy, Norway, Portugal, Spain, and Turkey) (NCT00797641; ENERGIB). Turkey contributed 23 sites to this study. Adult patients (≥18 years old) consecutively admitted to hospital and who underwent endoscopy for overt non-variceal upper gastrointestinal bleeding (hematemesis, melena or hematochezia, with other clinical/laboratory evidence of acute upper GI blood loss) were included in the study. Data were collected from patient medical records regarding bleeding continuation, re-bleeding, pharmacological treatment, surgery, and mortality during a 30-day follow-up period. A total of 423 patients (67.4% men; mean age: 57.8 ± 18.9 years) were enrolled in the Turkish study centers, of whom 96.2% were admitted to hospital with acute non-variceal upper gastrointestinal bleeding. At admission, the most common symptom was melena (76.1%); 28.6% of patients were taking aspirin, 19.9% were on non-steroidal anti-inflammatory drugs, and 7.3% were on proton pump inhibitors. The most common diagnoses were duodenal (45.2%) and gastric (27.7%) ulcers and gastritis/gastric erosions (26.2%). Patients were most often managed in general medical wards (45.4%). A gastrointestinal team was in charge of treatment in 64.8% of cases. Therapeutic procedures were performed in 32.4% of patients during endoscopy. After the endoscopy, most patients (94.6%) received proton pump inhibitors. Mean (SD) hospital stay was 5.36 ± 4.91 days. The cumulative proportions of continued bleeding/re-bleeding, complications and mortality within 30 days of the non-variceal upper gastrointestinal bleeding episode were 9.0%, 5.7% and 2.8%, respectively. In the Turkish sub-group of patients, the significant risk factors for bleeding continuation or re-bleeding were age >65 years, presentation with hematemesis or shock/syncope, and the diagnosis of duodenal ulcer. The risk of clinical complications after non-variceal upper gastrointestinal bleeding was higher in female patients older than 65 years, in patients with comorbidities, and in patients presenting with shock/syncope, and also according to time to endoscopy. The use of aspirin, non-steroidal anti-inflammatory drugs or warfarin at baseline was negatively associated with the development of bleeding or clinical complications. The risk of death within 30 days after non-variceal upper gastrointestinal bleeding was significantly higher in patients older than 65 years and in those receiving transfusions other than intravenous fluid or red blood cells within 12 hours of presentation. According to the survey results, non-variceal upper gastrointestinal bleeding in Turkey varies from that in other European countries in a number of aspects. These differences could be associated with a younger population and Helicobacter pylori incidence. Despite the diminishing need for surgical intervention and mortality rates for non-variceal upper gastrointestinal bleeding, as is the case in other European countries, non-variceal upper gastrointestinal bleeding remains a serious problem.
Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.
Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid
2009-10-01
In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.
49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope. This standard specifies performance, labeling, and certification requirements for retreaded pneumatic...
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
2013-01-01
This article focuses on the incidence, predictors, classification, impact on prognosis, and management of bleeding associated with the treatment of acute coronary syndrome. The issue of bleeding complications is related to the continual improvement of ischemic heart disease treatment, which involves mainly (a) the widespread use of coronary angiography, (b) developments in percutaneous coronary interventions, and (c) the introduction of new antithrombotics. Bleeding has become an important health and economic problem and has an incidence of 2.0% to 17%. Bleeding significantly influences both the short- and long-term prognoses. If a group of patients at higher risk of bleeding complications can be identified according to known risk factors and a risk scoring system can be developed, we may focus more on preventive measures that should help us to reduce the incidence of bleeding. PMID:24093465
Microvalve-based microfluidic device for C. elegans manipulation
NASA Astrophysics Data System (ADS)
Johari, S.; Nock, V.; Alkaisi, M. M.; Wang, W.
2017-09-01
In this paper, we report on the integration of a force measurement application capable of continuously measuring the forces generated by C. elegans in motion with a series of controllable microvalves which have an additional ability to increase control over worm selection and manipulation. The three-layer device consists of a pneumatic layer at the top, and a fluidic layer at the bottom with a thin PDMS membrane which functions as a microvalve sandwiched in between. The pneumatic layer functions as valves, whose operation is controlled pneumatically. The fluidic layer contains of PDMS micropillars for resolving the worm force from the deflection of the cantilever-like pillars. The measured force is horizontal and equivalent to a point force acting at half of the pillar height. By carefully controlling the incorporated microvalves, the proposed device is able to select and direct worm movement and at the same time increase the number of force measurement results collected. The integration of the microvalve with the PDMS micropillar-based on chip system can be easily combined with existing screening and imaging systems and also has the capability to facilitate high-throughput screening of force patterns in C. elegans locomotion behaviour.
Development of gait training system powered by pneumatic actuator like human musculoskeletal system.
Yamamoto, Shin-ichiroh; Shibata, Yoshiyuki; Imai, Shingo; Nobutomo, Tatsuya; Miyoshi, Tasuku
2011-01-01
The purpose of this study was to develop a body weight support gait training system for stroke and spinal cord injury (SCI) patient. This system consists of an orthosis powered by pneumatic McKibben actuators and a piece of equipment of body weight support. The attachment of powered orthosis can be fit to individual subjects with different body size. This powered orthosis is driven by pneumatic McKibben actuators arranged as a pair of agonistic and antagonistic bi-articular muscle models and two pairs of agonistic and antagonistic mono-articular muscle models like the human musculoskeletal system. The body weight support equipment suspends the subject's body in a wire harness, with the body weight is supported continuously by a counterweight. The powered orthosis is attached to the body weight support equipment by a parallel linkage, and its movement of powered orthosis is limited at the sagittal plane. The weight of the powered orthosis is compensated by a parallel linkage with a gas-spring. In this paper, we report the detailed mechanics of this body weight support gait training system and the results of several experiments for evaluating the system. © 2011 IEEE
Adding the ‘heart’ to hanging drop networks for microphysiological multi-tissue experiments†
Yazdi, Saeed Rismani; Shadmani, Amir; Bürgel, Sebastian C.; Misun, Patrick M.; Hierlemann, Andreas; Frey, Olivier
2017-01-01
Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid–air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip. PMID:26401602
Jensen, Jeffrey T; Archer, David F
2008-02-01
Considerable recent interest has focused on new methods of delivery of oral contraceptives that reduce or eliminate the hormone-free interval in order to improve convenience and acceptability, but maintain contraceptive efficacy, minimize side effects and reduce or eliminate the frequency of withdrawal bleeding episodes. Studies in several countries, including the US, have documented that many women would prefer to have no episodes of withdrawal bleeding when using oral contraceptives. This review focuses on a unique oral contraceptive formulation containing levonogestrel 90 microg and ethinyl estradiol 20 microg, approved for use in a continuous dosing regimen designed to eliminate withdrawal bleeding throughout the entire year.
Hybrid Environmental Control System Integrated Modeling Trade Study Analysis for Commercial Aviation
NASA Astrophysics Data System (ADS)
Parrilla, Javier
Current industry trends demonstrate aircraft electrification will be part of future platforms in order to achieve higher levels of efficiency in various vehicle level sub-systems. However electrification requires a substantial change in aircraft design that is not suitable for re-winged or re-engined applications as some aircraft manufacturers are opting for today. Thermal limits arise as engine cores progressively get smaller and hotter to improve overall engine efficiency, while legacy systems still demand a substantial amount of pneumatic, hydraulic and electric power extraction. The environmental control system (ECS) provides pressurization, ventilation and air conditioning in commercial aircraft, making it the main heat sink for all aircraft loads with exception of the engine. To mitigate the architecture thermal limits in an efficient manner, the form in which the ECS interacts with the engine will have to be enhanced as to reduce the overall energy consumed and achieve an energy optimized solution. This study examines a tradeoff analysis of an electric ECS by use of a fully integrated Numerical Propulsion Simulation System (NPSS) model that is capable of studying the interaction between the ECS and the engine cycle deck. It was found that a peak solution lays in a hybrid ECS where it utilizes the correct balance between a traditional pneumatic and a fully electric system. This intermediate architecture offers a substantial improvement in aircraft fuel consumptions due to a reduced amount of waste heat and customer bleed in exchange for partial electrification of the air-conditions pack which is a viable option for re-winged applications.
Elbasty, Ahmed; Metcalf, James
2017-12-01
Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration's tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured.
Matytsina-Quinlan, Lyubov; Matytsina, Laura
2015-01-01
A woman in her late 40s presented with excessive per vagina (PV) bleeding and uterine fibroid. She reported excessive PV bleeding after starting Esmya; she was brought in by ambulance to the emergency department with profuse bleeding. Abnormal uterine bleeding (AUB) developed after selective progesterone receptor modulator (SPRM) administration in this symptomatic patient with uterine fibroid. The drug was withheld and surgical treatment considered. Progressive deterioration of PV bleeding after receiving SPRM led to an urgent laparoscopic total hysterectomy, which had to be postponed due to severe anaemia. Surgery took place regardless because the excessive bleeding continued. Histology revealed a 6 cm submucosal uterine fibroid (SMUF) and adenomyosis. Physicians prescribing SPRMs to stop PV bleeding should be aware of potential AUB, which could lead to urgent hysterectomy. The mechanism of action of SPRMs is not clearly understood. Awareness of the side effects of Esmya, such as AUB, must be kept in mind when administering SPRMs. PMID:25976198
Matytsina-Quinlan, Lyubov; Matytsina, Laura
2015-05-14
A woman in her late 40s presented with excessive per vagina (PV) bleeding and uterine fibroid. She reported excessive PV bleeding after starting Esmya; she was brought in by ambulance to the emergency department with profuse bleeding. Abnormal uterine bleeding (AUB) developed after selective progesterone receptor modulator (SPRM) administration in this symptomatic patient with uterine fibroid. The drug was withheld and surgical treatment considered. Progressive deterioration of PV bleeding after receiving SPRM led to an urgent laparoscopic total hysterectomy, which had to be postponed due to severe anaemia. Surgery took place regardless because the excessive bleeding continued. Histology revealed a 6 cm submucosal uterine fibroid (SMUF) and adenomyosis. Physicians prescribing SPRMs to stop PV bleeding should be aware of potential AUB, which could lead to urgent hysterectomy. The mechanism of action of SPRMs is not clearly understood. Awareness of the side effects of Esmya, such as AUB, must be kept in mind when administering SPRMs. 2015 BMJ Publishing Group Ltd.
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...
Compensating for pneumatic distortion in pressure sensing devices
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Leondes, Cornelius T.
1990-01-01
A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monsein, L.H.; Davis, M.
CT scanning, MRI, and ultrasonography are the imaging procedures of choice for the study of rectus sheath hematomas. A rectus sheath hematoma was evaluated scintigraphically after the intravenous administration of Tc-99m labeled RBC, which confirmed the hematoma, demonstrated the sites of bleeding, and revealed continued bleeding.
Rojanaworarit, Chanapong; Limsawan, Soontaree
2017-01-01
This study aimed to estimate the risk of bleeding following minor oral surgical procedures and uninterrupted aspirin therapy in high-risk patients or patients with existing chronic diseases compared to patients who did not use aspirin during minor oral surgery at a public hospital. This retrospective cohort study analyzed the data of 2912 patients, aged 20 years or older, who underwent 5251 minor oral surgical procedures at a district hospital in Thailand. The aspirin group was comprised of patients continuing aspirin therapy during oral surgery. The non-aspirin group (reference) included all those who did not use aspirin during surgery. Immediate and late-onset bleeding was evaluated in each procedure. The risk ratio of bleeding was estimated using a multilevel Poisson regression. The overall cumulative incidence of immediate bleeding was 1.3% of total procedures. No late-onset bleeding was found. A significantly greater incidence of bleeding was found in the aspirin group (5.8% of procedures, p<0.001). After adjusting for covariates, a multilevel Poisson regression model estimated that the bleeding risk in the aspirin group was 4.5 times higher than that of the non-aspirin group (95% confidence interval, 2.0 to 10.0; p<0.001). However, all bleeding events were controlled by simple hemostatic measures. High-risk patients or patients with existing chronic diseases who continued aspirin therapy following minor oral surgery were at a higher risk of hemorrhage than general patients who had not used aspirin. Nonetheless, bleeding complications were not life-threatening and could be promptly managed by simple hemostatic measures. The procedures could therefore be provided with an awareness of increased bleeding risk, prepared hemostatic measures, and postoperative monitoring, without the need for discontinuing aspirin, which could lead to more serious complications.
Chan, Francis K L; Leung Ki, En-Ling; Wong, Grace L H; Ching, Jessica Y L; Tse, Yee Kit; Au, Kim W L; Wu, Justin C Y; Ng, Siew C
2016-08-01
It is not clear whether use of low-dose aspirin should be resumed after an episode of lower gastrointestinal (GI) bleeding. We assessed the long-term risks of recurrent lower GI bleeding and serious cardiovascular outcomes after aspirin-associated lower GI bleeding. We performed a retrospective study of patients diagnosed with lower GI bleeding (documented melena or hematochezia and absence of upper GI bleeding) from January 1, 2000 through December 31, 2007 at the Prince of Wales Hospital in Hong Kong. Using the hospital registry, we analyzed data from 295 patients on aspirin and determined their outcomes during a 5-year period. Outcomes included recurrent lower GI bleeding, serious cardiovascular events, and death from other causes, as determined by an independent, blinded adjudication committee. Outcomes were compared between patients assigned to the following groups based on cumulative duration of aspirin use: <20% of the follow-up period (121 nonusers) vs ≥50% of the observation period (174 aspirin users). Within 5 years, lower GI bleeding recurred in 18.9% of aspirin users (95% confidence interval [CI], 13.3%-25.3%) vs 6.9% of nonusers (95% CI, 3.2%-12.5%; P = .007). However, serious cardiovascular events occurred in 22.8% of aspirin users (95% CI, 16.6%-29.6%) vs 36.5% of nonusers (95% CI, 27.4%-45.6%; P = .017), and 8.2% of aspirin users died from other causes (95% CI, 4.6%-13.2%) vs 26.7% of nonusers (95% CI, 18.7%-35.4%; P = .001). Multivariable analysis showed that aspirin use was an independent predictor of rebleeding, but protected against cardiovascular events and death. Among aspirin users with a history of lower GI bleeding, continuation of aspirin is associated with an increased risk of recurrent lower GI bleeding, but reduced risk of serious cardiovascular events and death. Copyright © 2016. Published by Elsevier Inc.
Testing techniques for determining static mechanical properties of Pneumatic tires
NASA Technical Reports Server (NTRS)
Dodge, R. N.; Larson, R. B.; Clark, S. K.; Nybakken, G. H.
1974-01-01
Fore-aft, lateral, and vertical spring rates of model and full-scale pneumatic tires were evaluated by testing techniques generally employed by industry and various testing groups. The purpose of this experimental program was to investigate what effects the different testing techniques have on the measured values of these important static tire mechanical properties. The testing techniques included both incremental and continuous loadings applied at various rates over half, full, and repeated cycles. Of the three properties evaluated, the fore-aft stiffness was demonstrated to be the most affected by the different testing techniques used to obtain it. Appreciable differences in the fore-aft spring rates occurred using both the increment- and continuous-loading techniques; however, the most significant effect was attributed to variations in the size of the fore-aft force loop. The dependence of lateral stiffness values on testing techniques followed the same trends as that for fore-aft stiffness, except to a lesser degree. Vertical stiffness values were found to be nearly independent of testing procedures if the nonlinear portion of the vertical force-deflection curves is avoided.
Photocoagulation in the treatment of bleeding peptic ulcer
NASA Astrophysics Data System (ADS)
Otto, Wlodzimierz; Paczkowski, Pawel M.
1996-03-01
The authors present their experience in the endoscopic laser photocoagulation of bleeding peptic ulcer. From 1991 to June 1995, 203 patients admitted for UGI bleeding from peptic ulcer have been treated by this method. The source of bleeding was confirmed by endoscopy. The patients were divided into two groups: actively bleeding peptic ulcer (group IA and IB according to Forrest's classification) and ulcer with stigmata of recent bleeding (group IIA/IIB). The former group consisted of 106 patients, among whom over 40 percent (45 patients) presented signs of hypovolemic shock on admission. Nd:YAG laser (Surgical Laser Technologies) was used in a continuous mode with a contact (8 - 20 watts) or non-contact (over 50 watts) method of coagulation. In actively bleeding patients photocoagulation resulted in stopping the hemorrhage in 95 (90%). Recurrent bleeding occurred in 16 cases; in 9 of them it was stopped by repeated photocoagulation. In this group 18 patients required surgical intervention. The mortality was of 10.3% (11 patients). In 97 patients with recent bleeding stigmata photocoagulation provoked heavy hemorrhage in 3 (in 2 cases stopped by prolonged coagulation). In 9 of the remaining 94 patients recurrent bleeding occurred. Nine patients required surgical intervention. Mortality in this group was of 6%.
ENDOSCOPIC DIAGNOSIS AND THERAPY IN GASTRO-ESOPAGEAL VARICEAL BLEEDING
Sanyal, Arun J.
2016-01-01
Gastroesophageal variceal hemorrhage is a medical emergency with high morbidity and mortality. Endoscopic therapy is the mainstay of management of bleeding varices. It requires attention to technique and the appropriate choice of therapy for a given patient at a given point in time. Subjects must be monitored continuously after initiation of therapy for control of bleeding and second line definitive therapies introduced quickly if endoscopic and pharmacologic treatment fails. PMID:26142034
Heikinheimo, O.; Inki, P.; Schmelter, T.; Gemzell-Danielsson, K.
2014-01-01
STUDY QUESTION What is the bleeding pattern during second consecutive levonorgestrel-releasing intrauterine system (LNG-IUS) use? SUMMARY ANSWER Consecutive use of LNG-IUS is associated with a predictable bleeding pattern, characterized by the absence of the initial period of irregular bleeding seen after interval insertion of an LNG-IUS and a non-bleeding pattern in the vast majority of women. WHAT IS KNOWN ALREADY With increased popularity of the LNG-IUS for long-term birth control and treatment of heavy menstrual bleeding (HMB), consecutive use of the system is becoming more frequent. One previous study showed 60% amenorrhea rate in consecutive IUS users; however, the sample size was small. STUDY DESIGN, SIZE, DURATION A prospective multicenter study in four European countries recruited women who wished to continue with LNG-IUS use immediately after the first 5-year period. A total of 204 women were followed up until the end of the first year of the second IUS. Thereafter 170 women continued into the extension phase of the study up to the full 5 years of use of the second IUS and 144 women continued to the end of the study. PARTICIPANTS, SETTING, METHODS A total of 170 women (mean age 39 years) who had been using their first LNG-IUS for between 4 years 3 months and 4 years 9 months, either for contraception or for treatment of HMB, and who planned to replace the device with a new LNG-IUS, were recruited and followed up to 5 years of the second IUS use. A total of 17 centers in four European countries were involved in the study. Bleeding patterns were analyzed using daily bleeding diaries using 90-day reference periods (RP) for the first year of the second IUS use and for the last RP of each year during Years 2–5 of use. MAIN RESULTS AND THE ROLE OF CHANCE Approximately 70% of women were free of bleeding during Years 2–5 and up to 49% were amenorrheic. There was a slight increase in the number of bleeding/spotting days of ∼3 days during the first RP immediately after the placement of the second IUS, whereafter the number of bleeding/spotting days returned to the level preceding the second IUS insertion or below that. Absence of bleeding was associated with high overall satisfaction and continuation rates. No serious adverse events assessed as related to the LNG-IUS use occurred during the 5-year period. The cumulative expulsion rate during the 5-year study period was 1.2%. The sample size was large enough to study bleeding patterns, and subjects are likely to represent typical consecutive IUS users, and therefore, the role of chance is small. LIMITATIONS, REASONS FOR CAUTION The women represent a selected group as they had already successfully used their first IUS for almost 5 years and were willing to continue its use—however, this is currently a common clinical situation. The results may therefore not be extrapolated to first-time users of the LNG-IUS. WIDER IMPLICATIONS OF THE FINDINGS These data are of importance when counseling women who are making decisions concerning long-term contraception. STUDY FUNDING/COMPETING INTEREST(S) This study was funded by Bayer Pharma AG. P.I. and T.S. are full-time employees of Bayer Pharma AG. O.H. and K. G-D. have received consultancy fees from Bayer Pharma AG. The publication was developed jointly by all authors without third-party involvement and no honoraria were paid for any authors for their contribution to this manuscript. TRIAL REGISTRATION NUMBER NCT00393198. PMID:24682613
The 3-D CFD modeling of gas turbine combustor-integral bleed flow interaction
NASA Technical Reports Server (NTRS)
Chen, D. Y.; Reynolds, R. S.
1993-01-01
An advanced 3-D Computational Fluid Dynamics (CFD) model was developed to analyze the flow interaction between a gas turbine combustor and an integral bleed plenum. In this model, the elliptic governing equations of continuity, momentum and the k-e turbulence model were solved on a boundary-fitted, curvilinear, orthogonal grid system. The model was first validated against test data from public literature and then applied to a gas turbine combustor with integral bleed. The model predictions agreed well with data from combustor rig testing. The model predictions also indicated strong flow interaction between the combustor and the integral bleed. Integral bleed flow distribution was found to have a great effect on the pressure distribution around the gas turbine combustor.
The effect of pneumatic dilation in management of postfundoplication dysphagia.
Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M
2017-06-01
Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.
Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.
Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian
2015-11-01
A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.
Rhee, Minsoung
2010-01-01
We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730
Treatments for pediatric achalasia: Heller myotomy or pneumatic dilatation?
Jung, C; Michaud, L; Mougenot, J-F; Lamblin, M-D; Philippe-Chomette, P; Cargill, G; Bonnevalle, M; Boige, N; Bellaïche, M; Viala, J; Hugot, J-P; Gottrand, F; Cezard, J-P
2010-03-01
The treatment of achalasia consists of reducing distal esophageal obstruction by either Heller myotomy surgery or endoscopic pneumatic dilatation. The aim of the present study was to evaluate the short- and middle-term results of these procedures in children. For technical reasons, children under six years old (n=8) were treated by surgery only, whereas patients over six years old (n=14) were treated by either Heller myotomy or pneumatic dilatation. Of the children aged under six years, 75% were symptom-free at six months and 83% at 24 months of follow-up. Of the patients aged over six years, complete remission was achieved by Heller myotomy in 44.5% vs. 55.5% by pneumatic dilatation after six months, and in 40% vs. 65%, respectively, after 24 months. Both pneumatic dilatation and Heller myotomy showed significant rates of failure. These results suggest that pneumatic dilatation may be considered a primary treatment in children over six years old. Also, where necessary, Heller myotomy and pneumatic dilatation may be used as complementary treatments.
[Morphine self-administration by rats using a pneumatic syringe].
Akiyama, Y; Takayama, S
1988-06-01
An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.
Key issues in theoretical and functional pneumatic design
NASA Astrophysics Data System (ADS)
Xu, Z. G.; Yang, D. Y.; Liu, W. M.; Liu, T. T.
2017-10-01
This paper studies the energy release of the pneumatic engine in different thermodynamic processes, the isothermal process is the highest power output process, while adiabatic process is the lowest energy output process, and the energy release of the pneumatic engine is a multi-state thermodynamic process between them. Therefore heat exchanging should be increased between the pneumatic engine and the outer space, the gas expansion process in the cylinder should be as close as possible to the isothermal process. Heat exchange should be increased between the cylinder and the external spaces. Secondly, the fin structure is studied to increase the heat exchanging between the cylinder body and the outside space. The upper part has fin structures and the lower cylinder has no fin structure, this structure improved the working efficiency of pneumatic engine. Finally the cam and the hydraulic bottle of pneumatic engines are designed. Simulation and theoretical calculation are used to the analysis of the whole structure, which lay the foundation for the manufacturing and design of the pneumatic engines.
Ghosh, Tonmoy; Fattah, Shaikh Anowarul; Wahid, Khan A
2018-01-01
Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data.
Concurrent Use of Warfarin and Antibiotics and the Risk of Bleeding in Older Adults
Baillargeon, Jacques; Holmes, Holly M.; Lin, Yu-li; Raji, Mukaila A.; Sharma, Gulshan; Kuo, Yong-Fang
2011-01-01
Background Antibiotic medications are associated with an increased risk of bleeding among patients receiving warfarin. The recent availability of data from the Medicare Part D prescription drug program provides an opportunity to assess the association of antibiotic medications and the risk of bleeding in a national population of older adults receiving warfarin. Methods We conducted a case-control study nested within a cohort of 38,762 patients aged 65 years and older who were continuous warfarin users, using enrollment and claims data for a 5% national sample of Medicare beneficiaries with Part D benefits. Cases were defined as persons hospitalized for a primary diagnosis of bleeding and were matched with three control subjects on age, race, gender, and indication for warfarin. Logistic regression analysis was used to calculate adjusted odds ratios (aORs) and 95% confidence intervals (CIs) for the risk of bleeding associated with prior exposure to antibiotic medications. Results Exposure to any antibiotic agent within the 15 days of the event/index date was associated with an increased risk of bleeding (aOR 2.01; 95% CI, 1.62-2.50). All six specific antibiotic drug classes examined [azole antifungals (aOR, 4.57; 95% CI, 1.90-11.03), macrolides (aOR, 1.86; 95% CI, 1.08-3.21), quinolones (aOR, 1.69; 95% CI, 1.09-2.62), cotrimoxazole (aOR, 2.70; 95% CI, 1.46-5.05), penicillins (aOR, 1.92; 95% CI, 1.21-2.07) and cephalosporins (aOR, 2.45; 95% CI, 1.52-3.95) were associated with an increased risk of bleeding. Conclusion Among older continuous warfarin users, exposure to antibiotic agents—particularly azole antifungals—was associated with an increased risk of bleeding. PMID:22269622
A Study of Gas Economizing Pneumatic Cylinder
NASA Astrophysics Data System (ADS)
Li, T. C.; Wu, H. W.; Kuo, M. J.
2006-10-01
The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.
Kinoshita, Haruyuki; Akiyama, Naoko; Murao, Masaki; Yamauchi, Yosuke; Nakamura, Teruya; Sekiya, Naosumi; Toyota, Naoyuki; Miyagatani, Yasusuke
2015-05-01
We experienced a case of a subtype of spontaneous hemopneumothorax caused by external forces associated with a seat-belt injury. A female aged 39 years sustained a minor collision with an oncoming car while she was driving. Although pneumothorax was not detected, hemothorax and bleeding from the area surrounding the subclavian artery were observed on contrast-enhanced chest computed tomography (CT). After confirming continuous bleeding into the thoracic cavity after superselective arterial embolization, we performed emergency open surgery. We found a bulla in the apex of the lung, and the thoracic stump of the bulla was considered the source of bleeding. In this case, the direct cause of hemothorax was considered to be the external force associated with the seat-belt injury. When a bulla in the apex of the lung and continuous bleeding are both observed on CT, spontaneous hemopneumothorax should be suspected, necessitating open chest surgery in cases where pneumothorax is not observed.
Dislodgement of variceal bands after esophageal balloon tamponade for variceal bleeding.
Mogrovejo, Estela; Manickam, Palaniappan; Polidori, Gregg; Cappell, Mitchell S
2014-01-01
A 43-year-old male with alcoholic cirrhosis underwent EGD for hematemesis which revealed bleeding, grade II, lower esophageal varices that were endoscopically ligated with 6 bands. All the bands remained attached to varices at the completion of EGD. Despite apparent initial hemostasis, balloon tamponade was performed one hour later for suspected continued bleeding. Due to suspected continuing bleeding, EGD was repeated 4 h after initial EGD, and 3 h after balloon tamponade. This EGD revealed the esophageal varices; none of the bands remaining on esophageal mucosa; multiple mucosal stigmata likely from trauma at initial site of variceal bands before dislodgement; and 3 dislodged bands in gastric body, duodenal bulb, or descending duodenum. The patient expired 17 h thereafter from hypovolemic shock. This single report may suggest an apparently novel, balloon tamponade complication: dislodgement of previously placed, endoscopic bands. The proposed pathophysiology is release of bands by stretching entrapped, esophageal mucosa during esophageal balloon tamponade. This complication, if confirmed, might render balloon tamponade a less desirable option very soon after band ligation.
Experimental research of flow servo-valve
NASA Astrophysics Data System (ADS)
Takosoglu, Jakub
Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.
Severe gastric variceal bleeding successfully treated by emergency splenic artery embolization.
Sankararaman, Senthilkumar; Velayuthan, Sujithra; Vea, Romulo; Herbst, John
2013-06-01
Bleeding from gastric varices due to splenic vein obstruction is extremely rare in children, but it can be catastrophic. Reported herein is the case of a teenager with splenic vein thrombosis and chronic decompensated liver disease from autoimmune hepatitis who presented with massive gastric variceal bleeding. Standard medical management did not control the bleeding. Due to decompensated liver disease and continuous active bleeding, emergency partial splenic artery embolization was preferred over splenectomy or a shunt procedure. Bleeding was successfully controlled by partial splenic artery embolization by decreasing the inflow of blood into the portal system. It is concluded that emergency partial splenic artery embolization is a safer alternative life-saving procedure to manage severe gastric variceal bleeding due to splenic vein obstruction in a patient with high surgical risk. To our knowledge, only one other patient with similar management has been reported in the pediatric age group. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.
Kawasaki, Keisuke; Nakamura, Shotaro; Kurahara, Koichi; Nagasue, Tomohiro; Yanai, Shunichi; Harada, Akira; Yaita, Hiroki; Fuchigami, Tadahiko; Matsumoto, Takayuki
2017-09-01
The aim of this study was to compare clinical characteristics and outcomes of bleeding gastroduodenal ulcer between patients taking antithrombotic medications and those not taking antithrombotic medications. We performed a case-control study of 346 patients with endoscopically verified bleeding gastroduodenal ulcer, which included 173 cases taking antithrombotic medications throughout peri-bleeding period and 173 age- and sex-matched controls not taking antithrombotic medications. The cases showed less frequent Helicobacter pylori (H. pylori) infections (45.1% versus 60.7%, p = .005), more frequent duodenal location (31.8% versus 19.1%, p = .009), and more frequent rebleeding (13.9% versus 5.8%, p = .02) than the controls. Multivariate analysis revealed that duodenal location (odds ratio [OR] 3.01, 95% confidence interval [CI] 1.37-6.65) and use of antithrombotic medications (OR 2.47, 95% CI 1.13-5.77) were independent factors for rebleeding. However, there were no differences in clinical outcomes, including final successful endoscopic hemostasis, need for surgical intervention, and mortality between cases and controls. Thromboembolic events did not occur in any cases and controls during the periendoscopic period. Low prevalence of H. pylori infection, frequent duodenal location, and high rebleeding rate are characteristics of patients with bleeding gastroduodenal ulcer under antithrombotic medications. Continuation of antithrombotic medications can be accepted for bleeding gastroduodenal ulcer.
Wang, Wen-ying; Cui, Nian-hui; Wang, En-bo; Zhang, Wei
2013-05-01
To investigate the feasibility of continuation of aspirin before tooth extraction in the elderly. The patients enrolled in this study were the elderly requiring a single non-impacted tooth extraction. 300 elderly outpatients used lidocaine local infiltration anesthesia, 200 patients without using aspirin before tooth extraction served as control group I, 100 patients with prolong use of aspirin before tooth extraction as observation group I. 300 elderly outpatients used compound articaine local infiltration anesthesia, 200 patients without using aspirin before tooth extraction served as control group II, 100 patients with prolong use of aspirin before tooth extraction as observation group II.Bleedings at 5, 10, 30 min, 24 h after tooth extraction were observed and the relationship between postoperative bleeding and intake of aspirin was analyzed. There was no significant difference at 5, 10, 30 min, 24 h in postoperative bleeding after extraction between control group I and observation group. The incidence of bleeding of observation group II after tooth extraction at 5 min was higher than that of control group II and there was no significant difference at 10, 30 min, 24 h between the two groups. Continuation of aspirin have no influence on postoperative bleeding. Therefore we suggest that there was no indication to discontinue aspirin for the elderly before a single non-impacted tooth extraction.
Occult gastrointestinal bleeding. An evaluation of available diagnostic methods.
Richardson, J D; McInnis, W D; Ramos, R; Aust, J B
1975-05-01
Occult gastrointestinal bleeding was defined as continued bleeding in spite of a normal series of roentgenorgrams of the upper part of the gastrointestinal tract, barium enema, and sigmoidoscopy. Twenty-six such patients were treated. A thorough systematic evaluation, including gastroscopy, colonoscopy, visceral angiography, and isotopic scanning, was done preoperatively. Using colonoscopy and arteriography, nearly 60% of the bleeding sites were identified. Seventy-six percent of the lesions identified were in the terminal part of the ileum or the ascending colon. Exploratory laparotomy should be performed for life-threatening hemorrhage or as a diagnostic test only after a thorough preoperative evaluation. If results of a complete preoperative evaluation including arteriography were normal, then the likelihood of finding a discrete cause of bleeding at laparotomy was high (80%). A systematic evaluation and diligence of both physcian and patient in localizing the site of bleeding are essential.
Lin, Hao-Ting
2017-06-04
This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally.
Lin, Hao-Ting
2017-01-01
This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally. PMID:28587220
Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A
2018-02-01
Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.
Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.
2018-01-01
Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381
Driessen, Antoine H G; Krul, Sébastien P J; de Mol, Bas A J M; de Groot, Joris R
2012-06-01
Thoracoscopic surgery for atrial fibrillation (AF) is an attractive and emerging treatment modality. However, when a bleeding occurs access for hemostasis is limited. Therefore, a sternotomy might be necessary to stop the bleeding and continue the operation. We report 2 patients with a periprocedural bleeding in whom sternotomy could be prevented by tamponading the bleeding, interrupting the operation and resuming 3 weeks later. Our cases show that sternotomies can be prevented and that there is a second chance for thoracoscopic surgery for AF. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Control of soft machines using actuators operated by a Braille display.
Mosadegh, Bobak; Mazzeo, Aaron D; Shepherd, Robert F; Morin, Stephen A; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M
2014-01-07
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds-often built for a single purpose-are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled Braille display and a micropneumatic device. The Braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface.
Control of Soft Machines using Actuators Operated by a Braille Display
Mosadegh, Bobak; Mazzeo, Aaron D.; Shepherd, Robert F.; Morin, Stephen A.; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M.
2013-01-01
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds—often built for a single purpose—are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled braille display and a micropneumatic device. The braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface. PMID:24196070
[Modern pneumatic weapons and injuries they cause].
Kozachenko, I N
2013-01-01
The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.
Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S
2017-08-01
This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.
2014-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S
2013-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.
The medical management of abnormal uterine bleeding in reproductive-aged women.
Bradley, Linda D; Gueye, Ndeye-Aicha
2016-01-01
In the treatment of women with abnormal uterine bleeding, once a thorough history, physical examination, and indicated imaging studies are performed and all significant structural causes are excluded, medical management is the first-line approach. Determining the acuity of the bleeding, the patient's medical history, assessing risk factors, and establishing a diagnosis will individualize their medical regimen. In acute abnormal uterine bleeding with a normal uterus, parenteral estrogen, a multidose combined oral contraceptive regimen, a multidose progestin-only regimen, and tranexamic acid are all viable options, given the appropriate clinical scenario. Heavy menstrual bleeding can be treated with a levonorgestrel-releasing intrauterine system, combined oral contraceptives, continuous oral progestins, and tranexamic acid with high efficacy. Nonsteroidal antiinflammatory drugs may be utilized with hormonal methods and tranexamic acid to decrease menstrual bleeding. Gonadotropin-releasing hormone agonists are indicated in patients with leiomyoma and abnormal uterine bleeding in preparation for surgical interventions. In women with inherited bleeding disorders all hormonal methods as well as tranexamic acid can be used to treat abnormal uterine bleeding. Women on anticoagulation therapy should consider using progestin-only methods as well as a gonadotropin-releasing hormone agonist to treat their heavy menstrual bleeding. Given these myriad options for medical treatment of abnormal uterine bleeding, many patients may avoid surgical intervention. Copyright © 2016 Elsevier Inc. All rights reserved.
Method of sections in analytical calculations of pneumatic tires
NASA Astrophysics Data System (ADS)
Tarasov, V. N.; Boyarkina, I. V.
2018-01-01
Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.
Development of pneumatic actuator with low-wave reflection characteristics
NASA Astrophysics Data System (ADS)
Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.
2010-08-01
This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.
The use of antifibrinolytics in pediatric patients with hypoproliferative thrombocytopenia.
Delaney, Meghan; Matthews, Dana C; Gernsheimer, Terry B
2017-12-01
Despite the use of evidence-based platelet transfusion therapy during periods of hypoproliferative thrombocytopenia, a large proportion of pediatric hematology/oncology patients continue to suffer from clinically significant bleeding. Antifibrinolytic (AF) drugs have been shown in certain surgical and trauma settings to decrease bleeding, blood transfusion, and improve survival. We conducted a retrospective assessment of the safety of using AF drugs in pediatric patients with hypoproliferative thrombocytopenia at our center as well as the impact on bleeding occurrence and severity. © 2017 Wiley Periodicals, Inc.
Nishikawa, Masakatsu; Isshiki, Takaaki; Kimura, Takeshi; Ogawa, Hisao; Yokoi, Hiroyoshi; Miyazaki, Shunichi; Ikeda, Yasuo; Nakamura, Masato; Tanaka, Yuko; Saito, Shigeru
2017-04-01
Prasugrel is a third-generation thienopyridine that achieves potent platelet inhibition with less pharmacological variability than other thienopyridines. However, clinical experience suggests that prasugrel may be associated with a higher risk of de novo and recurrent bleeding events compared with clopidogrel in Japanese patients undergoing percutaneous coronary intervention (PCI). In this review, we evaluate the risk of bleeding in Japanese patients treated with prasugrel at the doses (loading/maintenance doses: 20/3.75 mg) adjusted for Japanese patients, evaluate the risk factors for bleeding in Japanese patients, and examine whether patients with a bleeding event are at increased risk of recurrent bleeding. This review covers published data and new analyses of the PRASFIT (PRASugrel compared with clopidogrel For Japanese patIenTs) trials of patients undergoing PCI for acute coronary syndrome or elective reasons. The bleeding risk with prasugrel was similar to that observed with the standard dose of clopidogrel (300/75 mg), including when bleeding events were re-classified using the Bleeding Academic Research Consortium criteria. The pharmacodynamics of prasugrel was not associated with the risk of bleeding events. The main risk factors for bleeding events were female sex, low body weight, advanced age, and presence of diabetes mellitus. Use of a radial puncture site was associated with a lower risk of bleeding during PCI than a femoral puncture site. Finally, the frequency and severity of recurrent bleeding events during continued treatment were similar between prasugrel and clopidogrel. In summary, this review provides important insights into the risk and types of bleeding events in prasugrel-treated patients.Trial registration numbers: JapicCTI-101339 and JapicCTI-111550.
Chiang, Mao-Hsiung
2010-01-01
This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.
Chiang, Mao-Hsiung
2010-01-01
This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally. PMID:22319266
Variable camber wing based on pneumatic artificial muscles
NASA Astrophysics Data System (ADS)
Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong
2009-07-01
As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.
Elbasty, Ahmed; Metcalf, James
2017-01-01
Purpose Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. Materials and Methods MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration’s tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Results Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. Conclusion CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured. PMID:29354622
WAN, BING; FU, HAI-YAN; YIN, JIANG-TAO; REN, GUO-QING
2015-01-01
The efficacy and safety of physiotherapeutic prophylaxis for venous thromboembolism in critically ill patients with heparin contraindication remains unclear. In the present study it was hypothesized that physiotherapy prophylaxis with intermittent pneumatic compression (IPC) would be safe and effective for patients unable to receive low-molecular-weight heparin (LMWH). In addition, this study investigated whether a combined therapy of IPC with LMWH would be more effective for the prophylaxis of deep vein thrombosis (DVT) in critical patients. A total of 500 patients were divided into four groups according to the prophylaxis of DVT. The IPC group consisted of 95 patients with heparin contraindication that received IPC treatment; the LMWH group consisted of 185 patients that received an LMWH injection; the LMWH + IPC group consisted of 75 patients that received IPC treatment and LMWH injection; and the control group consisted of 145 patients that received no IPC treatment or injection of LMWH. Each patient was evaluated clinically for development of DVT and the diagnosis was confirmed by Doppler study. Venous thromboembolism was a common complication among the trauma patients with severe injuries. Patients responded positively to the treatment used in the intervention groups. Patients exhibited an improved response to LMWH + ICP compared with IPC or LMWH alone, while no significant difference was detected between the IPC and LMWH groups. These results were applicable to patients that had a Wells score of ≥3; however, no significant differences in DVT incidence were observed among the patients who had a Wells score of <3. In this observational study, LMWH + ICP appeared to be more effective than either treatment alone in treating critically ill trauma patients with severe injuries that are at high risk for VTE and bleeding simultaneously. PMID:26668637
Management of antithrombotic therapy during cardiac implantable device surgery.
AlTurki, Ahmed; Proietti, Riccardo; Birnie, David H; Essebag, Vidal
2016-06-01
Anticoagulants are commonly used drugs that are frequently encountered during device placement. Deciding when to halt or continue the use of anticoagulants is a balance between the risks of thromboembolism versus bleeding. Patients taking warfarin with a high risk of thromboembolism should continue to take their warfarin without interruption during device placement while ensuring their international normalized ratio remains below 3. For patients who are taking warfarin and have low risk of thromboembolism, either interrupted or continued warfarin may be used, with no evidence to clearly support either strategy. There is little evidence to support continuing direct acting oral anticoagulants (DOACs) for device implantation. The timing of halting these medications depends largely on renal function. If bleeding occurs, warfarin׳s anticoagulation effect is reversible with vitamin K and activated prothrombin complex concentrate. There are no DOAC reversal agents currently available, but some are under development. Regarding antiplatelet agents, aspirin alone can be safely continued while clopidogrel alone may also be continued, but with a slightly higher bleeding risk. Dual antiplatelet therapy for bare-metal stent/drug-eluting stent implanted within 4 weeks/6 months, respectively, should be continued due to high risk of stent thrombosis; however, if they are implanted after this period, then clopidogrel can be halted 5 days before the procedure and resumed soon after, while aspirin is continued. If the patient is taking both aspirin and warfarin, aspirin should be halted 5 days prior to the procedure, while warfarin is continued.
Pneumatic wrench retains or discharges nuts or bolts as desired
NASA Technical Reports Server (NTRS)
Bouille, J. R.
1966-01-01
Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.
Prophylaxis of thromboembolism in bariatric surgery with parnaparin.
Forestieri, Pietro; Quarto, Gennaro; De Caterina, Maurizio; Cuocolo, Alberto; Pilone, Vincenzo; Formato, Antonio; Ruocco, Aldo; Ferrari, Patrizio
2007-12-01
There are limited data on appropriate dosing of low-molecular-weight heparins (LMWHs) for venous thromboembolism (VTE) prophylaxis in bariatric surgery. The primary objective of this preliminary study was to evaluate the preoperative effects of increasing doses of the LMWH parnaparin on coagulation in severely obese patients undergoing bariatric surgery. Severely obese patients (BMI > 50 kg/m(2)) were administered three increasing single doses of parnaparin (3200, 4250, and 6400 IU) on the three consecutive days leading up to biliointestinal bypass surgery. Activated partial thromboplastin time (APTT), anti-factor IIa and anti-factor Xa levels were measured 1 h before and 4 h after dosing. The highest dose (6400 IU/day) was continued from the day of surgery until day 30 (recovery period). Intermittent pneumatic compression and stockings were applied during surgery and the recovery period, respectively. Lower limb echoDoppler and phleboscintigraphy, and pulmonary scintigraphy were used for VTE detection. Ten patients (mean BMI 52.4 kg/m(2)) were recruited into this study. During the preoperative dosing phase, parnaparin dose-dependently prolonged APTT, with the 6400 IU dose significantly prolonging APTT versus the lower doses. Meanwhile, anti-factor Xa and anti-factor IIa activity was increased by the 4250 and 6400 IU doses. After surgery, one patient with heparin resistance experienced pulmonary embolization. No bleeding complications were observed. The dose-response data reported in this preliminary study suggest that parnaparin doses of 4250 and 6400 IU may provide effective prophylaxis for VTE in patients undergoing bariatric surgery. However, given the small number of patients, larger, well-controlled trials are required to confirm these findings.
NASA Astrophysics Data System (ADS)
Zheng, Y.; Liu, Q.; Li, Y.
2012-03-01
Solids moving with a gas stream in a pipeline can be found in many industrial processes, such as power generation, chemical, pharmaceutical, food and commodity transfer processes. A mass flow rate of the solids is important characteristic that is often required to be measured (and controlled) to achieve efficient utilization of energy and raw materials in pneumatic conveying systems. The methods of measuring the mass flow rate of solids in a pneumatic pipeline can be divided into direct and indirect (inferential) measurements. A thermal solids' mass flow-meter, in principle, should ideally provide a direct measurement of solids flow rate, regardless of inhomogeneities in solids' distribution and environmental impacts. One key issue in developing a thermal solids' mass flow-meter is to characterize the heat transfer between the hot pipe wall and the gas-solids dense phase flow. The Eulerian continuum modeling with gas-solid two phases is the most common method for pneumatic transport. To model a gas-solid dense phase flow passing through a heated region, the gas phase is described as a continuous phase and the particles as the second phase. This study aims to describe the heat transfer characteristics between the hot wall and the gas-solids dense phase flow in pneumatic pipelines by modeling a turbulence gas-solid plug passing through the heated region which involves several actual and crucial issues: selections of interphase exchange coefficient, near-wall region functions and different wall surface temperatures. A sensitivity analysis was discussed to identify the influence on the heat transfer characteristics by selecting different interphase exchange coefficient models and different boundary conditions. Simulation results suggest that sensitivity analysis in the choice of models is very significant. The simulation results appear to show that a combination of choosing the Syamlal-O'Brien interphase exchange coefficient model and the standard k-ɛ model along with the standard wall function model might be the best approach, by which, the simulation data seems to be closest to the experimental results.
Pneumatic conveyance apparatus and process
Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.
2010-05-04
A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.
Does the Degree of the Mastoid Pneumatization Affect the Side of Bell Palsy?
Güneş, Selçuk; Çelik, Mustafa; Çolak, Ceylan; Olgun, Burak
2018-02-26
The aim is to investigate the impact of degree of mastoid pneumatization on the affected side of Bell palsy (BP). Retrospective study in tertiary academic hospital. In total, 52 patients who were diagnosed with as BP were included in the study. Each patient was staged using House-Brackmann (HB) staging system. All patients underwent temporal bone computed tomography imaging. House-Brackmann scores, side of the BP, and mastoid pneumatization of all of patients were evaluated in the present study. Regarding the degree of the mastoid pneumatization, there were no significant differences between the affected side and the unaffected side (P = 0.439). The degree of the mastoid pneumatization of the affected side and the unaffected side did not differ between males and females (P = 0.918 for the affected side, P = 0.765 for the unaffected side, respectively). A negative correlation between the age and mastoid pneumatization of each side was found (P = 0.001, P = 0.025, respectively). There was no significant correlation between HB score and the degree of the mastoid pneumatization of each side (P = 0.789, P = 0.703). As a conclusion, the degree of the mastoid pneumatization is not one of the risk factors for BP. Further randomized studies with larger numbers of patients are needed to confirm these findings.
Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.
Balzeau, Antoine; Grimaud-Hervé, Dominique
2006-10-01
The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.
NASA Astrophysics Data System (ADS)
Burhan, I.; Azman, A. A.; Othman, R.
2016-10-01
An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.
Ko, Heung Kyu; Ko, Gi Young; Gwon, Dong Il; Kim, Jin Hyung; Han, Kichang; Lee, Shin-Wha
2017-01-01
Objective To evaluate the safety and efficacy of prophylactic uterine artery embolization (UAE) before obstetrical procedures with high risk for massive bleeding. Materials and Methods A retrospective review of 29 female patients who underwent prophylactic UAE from June 2009 to February 2014 was performed. Indications for prophylactic UAE were as follows: dilatation and curettage (D&C) associated with ectopic pregnancy (cesarean scar pregnancy, n = 9; cervical pregnancy, n = 6), termination of pregnancy with abnormal placentation (placenta previa, n = 8), D&C for retained placenta with vascularity (n = 5), and D&C for suspected gestational trophoblastic disease (n = 1). Their medical records were reviewed to evaluate the safety and efficacy of UAE. Results All women received successful bilateral prophylactic UAE followed by D&C with preservation of the uterus. In all patients, UAE followed by obstetrical procedure prevented significant vaginal bleeding on gynecologic examination. There was no major complication related to UAE. Vaginal spotting continued for 3 months in three cases. Although oligomenorrhea continued for six months in one patient, normal menstruation resumed in all patients afterwards. During follow-up, four had subsequent successful natural pregnancies. Spontaneous abortion occurred in one of them during the first trimester. Conclusion Prophylactic UAE before an obstetrical procedure in patients with high risk of bleeding or symptomatic bleeding may be a safe and effective way to manage or prevent serious bleeding, especially for women who wish to preserve their fertility. PMID:28246515
Unscheduled vaginal bleeding with progestin-only contraceptive use.
Zigler, Rachel E; McNicholas, Colleen
2017-05-01
Nearly 20% of women using contraception are using progestin-only contraception, including progestin-only pills, depot-medroxyprogesterone acetate, subdermal etonogestrel implants, and levonorgestrel intrauterine devices. This number will continue to grow with the increased provision of long-acting reversible contraception. Although overall satisfaction among women using progestin-only contraception is high, dissatisfaction and discontinuation may be associated with unscheduled bleeding and spotting. The exact etiology of irregular bleeding associated with progestin-containing contraceptives is not completely understood, yet several mechanisms have been suggested. Several therapies targeting these mechanisms have been evaluated with mixed results. This paper will review the physiology and management of unscheduled bleeding with progestin-containing contraceptives. Copyright © 2016 Elsevier Inc. All rights reserved.
Apostolaki, Naomi E.; Rayfield, Emily J.; Barrett, Paul M.
2015-01-01
Postcranial skeletal pneumaticity (PSP) is a condition most notably found in birds, but that is also present in other saurischian dinosaurs and pterosaurs. In birds, skeletal pneumatization occurs where bones are penetrated by pneumatic diverticula, membranous extensions that originate from air sacs that serve in the ventilation of the lung. Key questions that remain to be addressed include further characterizing (1) the skeletal features that can be used to infer the presence/absence and extent of PSP in birds and non-avian dinosaurs, and (2) the association between vertebral laminae and specific components of the avian respiratory system. Previous work has used vertebral features such as pneumatic foramina, fossae, and laminae to identify/infer the presence of air sacs and diverticula, and to discuss the range of possible functions of such features. Here, we tabulate pneumatic features in the vertebral column of 11 avian taxa, including the flightless ratites and selected members of semi-volant and semi-aquatic Neornithes. We investigate the associations of these osteological features with each other and, in the case of Struthio camelus, with the specific presence of pneumatic diverticula. We find that the mere presence of vertebral laminae does not indicate the presence of skeletal pneumaticity, since laminae are not always associated with pneumatic foramina or fossae. Nevertheless, laminae are more strongly developed when adjacent to foramina or fossae. In addition, membranous air sac extensions and adjacent musculature share the same attachment points on the vertebrae, rendering the use of such features for reconstructing respiratory soft tissue features ambiguous. Finally, pneumatic diverticula attach to the margins of laminae, foramina, and/or fossae prior to their intraosseous course. Similarities in PSP distribution among the examined taxa are concordant with their phylogenetic interrelationships. The possible functions of PSP are discussed in brief, based upon variation in the extent of PSP between taxa with differing ecologies. PMID:26649745
Legin, G A; Bondarchuk, A O; Perebetjuk, A N
2015-01-01
The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
A method of transmissibility design for dual-chamber pneumatic vibration isolator
NASA Astrophysics Data System (ADS)
Lee, Jeung-Hoon; Kim, Kwang-Joon
2009-06-01
Dual-chamber pneumatic vibration isolators have a wide range of applications for vibration isolation of vibration-sensitive equipment. Recent advances in precision machine tools and instruments such as medical devices and those related to nano-technology require better isolation performance, which can be efficiently achieved by precise modeling- and design- of the isolation system. This paper discusses an efficient transmissibility design method of a pneumatic vibration isolator wherein a complex stiffness model of a dual-chamber pneumatic spring developed in our previous study is employed. Three design parameters, the volume ratio between the two pneumatic chambers, the geometry of the capillary tube connecting the two pneumatic chambers, and, finally, the stiffness of the diaphragm employed for prevention of air leakage, were found to be important factors in transmissibility design. Based on a design technique that maximizes damping of the dual-chamber pneumatic spring, trade-offs among the resonance frequency of transmissibility, peak transmissibility, and transmissibility in high frequency range were found, which were not ever stated in previous researches. Furthermore, this paper discusses the negative role of the diaphragm in transmissibility design. The design method proposed in this paper is illustrated through experimental measurements.
Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation
NASA Technical Reports Server (NTRS)
Constantinescu, I. N.; Darabont, A. V.
1974-01-01
Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.
Safety and efficacy of BAY 94-9027, a prolonged-half-life factor VIII.
Reding, M T; Ng, H J; Poulsen, L H; Eyster, M E; Pabinger, I; Shin, H-J; Walsch, R; Lederman, M; Wang, M; Hardtke, M; Michaels, L A
2017-03-01
Essentials Recombinant factor VIII BAY 94-9027 conjugates in a site-specific manner with polyethylene glycol. BAY 94-9027 was given to patients with severe hemophilia A as prophylaxis and to treat bleeds. BAY 94-9027 prevented bleeds at dose intervals up to every 7 days and effectively treated bleeds. BAY 94-9027 treatment was mainly well tolerated and no patient developed factor VIII inhibitors. Click to hear Dr Tiede's perspective on half-life extended factor VIII for the treatment of hemophilia A SUMMARY: Background BAY 94-9027 is a B-domain-deleted prolonged-half-life recombinant factor VIII (FVIII) that conjugates in a site-specific manner with polyethylene glycol. Objective Assess efficacy and safety of BAY 94-9027 for prophylaxis and treatment of bleeds in patients with severe hemophilia A. Patients/methods In this multinational, phase 2/3, partially randomized, open-label trial, men aged 12-65 years with FVIII < 1% and ≥ 150 exposure days to FVIII received BAY 94-9027 for 36 weeks on demand or prophylactically at intervals determined following a 10-week run-in period on 25 IU kg -1 body weight two times per week. Patients with > 1 bleed during the run-in subsequently received 30-40 IU kg -1 two times per week; patients with ≤ 1 bleed were eligible for randomization to every-5-days (45-60 IU kg -1 ) or every-7-days (60 IU kg -1 ) prophylaxis (1 : 1) for 26 additional weeks until randomization arms were filled. Patients who were eligible but not randomized continued twice-weekly prophylaxis. The primary efficacy outcome was annualized bleeding rate (ABR). Results The intent-to-treat population included 132 patients (prophylaxis, n = 112; on demand, n = 20). Median ABR (quartile [Q1; Q3]) for patients treated two times per week who were not eligible for randomization (n = 13) improved after dose increase (17.4 [14.3; 26.0] to 4.1 [2.0; 10.6]). Median ABR for patients randomized to every-5-days treatment (n = 43) was 1.9 (0; 4.2), similar to patients eligible for randomization but who continued treatment two times per week (n = 11). Median ABR for 32/43 patients (74%) who continued every-7-days prophylaxis until study end was 0.96 (0.0; 4.3). Six hundred and thirty-six of 702 bleeds (90.6%) were controlled with ≤ 2 infusions. No patient developed a FVIII inhibitor. Conclusions BAY 94-9027 prevented bleeding across three individually tailored dose regimens and was effective for treatment of bleeds. © 2016 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.
Pantoprazole for the treatment of peptic ulcer bleeding and prevention of rebleeding.
van Rensburg, Christo J; Cheer, Susan
2012-01-01
Adding proton pump inhibitors (PPIs) to endoscopic therapy has become the mainstay of treatment for peptic ulcer bleeding, with current consensus guidelines recommending high-dose intravenous (IV) PPI therapy (IV bolus followed by continuous therapy). However, whether or not high-dose PPI therapy is more effective than low-dose PPI therapy is still debated. Furthermore, maintaining pH ≥ 4 appears to prevent mucosal bleeding in patients with acute stress ulcers; thus, stress ulcer prophylaxis with acid-suppressing therapy has been increasingly recommended in intensive care units (ICUs). This review evaluates the evidence for the efficacy of IV pantoprazole, a PPI, in preventing ulcer rebleeding after endoscopic hemostasis, and in controlling gastric pH and protecting against upper gastrointestinal (GI) bleeding in high-risk ICU patients. The review concludes that IV pantoprazole provides an effective option in the treatment of upper GI bleeding, the prevention of rebleeding, and for the prophylaxis of acute bleeding stress ulcers.
Pantoprazole for the Treatment of Peptic Ulcer Bleeding and Prevention of Rebleeding
van Rensburg, Christo J.; Cheer, Susan
2012-01-01
Adding proton pump inhibitors (PPIs) to endoscopic therapy has become the mainstay of treatment for peptic ulcer bleeding, with current consensus guidelines recommending high-dose intravenous (IV) PPI therapy (IV bolus followed by continuous therapy). However, whether or not high-dose PPI therapy is more effective than low-dose PPI therapy is still debated. Furthermore, maintaining pH ≥ 4 appears to prevent mucosal bleeding in patients with acute stress ulcers; thus, stress ulcer prophylaxis with acid-suppressing therapy has been increasingly recommended in intensive care units (ICUs). This review evaluates the evidence for the efficacy of IV pantoprazole, a PPI, in preventing ulcer rebleeding after endoscopic hemostasis, and in controlling gastric pH and protecting against upper gastrointestinal (GI) bleeding in high-risk ICU patients. The review concludes that IV pantoprazole provides an effective option in the treatment of upper GI bleeding, the prevention of rebleeding, and for the prophylaxis of acute bleeding stress ulcers. PMID:24833934
Expert opinion on a flexible extended regimen of drospirenone/ethinyl estradiol contraceptive.
Han, Leo; Jensen, Jeffrey T
2014-10-01
Oral contraceptives are often prescribed in extended or continuous forms in order to manage menstrual bleeding and menstrual-related side effects. However, with extended regimens, unscheduled intracycle bleeding can become problematic. Flexible extended dosing of a contraceptive containing drospirenone (DRSP) and ethinyl estradiol (EE) was designed to improve bleeding profiles during extended cycles through active management of bleeding symptoms. We examine the rationale for flexible extended dosing as well as review the dosing regimen. We will focus on the findings of the two most important clinical trials regarding flexible extended DRSP/EE (3 mg/20 μg), including the bleeding profiles of women in those trials. Pharmacology, mechanisms of action, efficacy as well as safety of DRSP containing pills will also be reviewed. Flexible extended dosing of DRSP/EE (3 mg/20 μg) has similar pharmacokinetics and contraceptive efficacy of both conventional and fixed extended regimens. However, it has the added benefit of fewer days of bleeding/spotting compared to conventional and fixed extended regimens.
Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.
Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M
2017-01-01
Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.
Gaffey, Ann C; Chen, Carol W; Chung, Jennifer J; Han, Jason; Bermudez, Christian A; Wald, Joyce; Atluri, Pavan
2018-02-13
Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs. We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes. There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59). We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.
Ghosh, Tonmoy; Wahid, Khan A.
2018-01-01
Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data. PMID:29468094
Basic Pneumatics. Instructor's Guide.
ERIC Educational Resources Information Center
Fessehaye, Michael
This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…
NASA Astrophysics Data System (ADS)
Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin
2011-12-01
This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
Majeed, Ammar; Wallvik, Niklas; Eriksson, Joakim; Höijer, Jonas; Bottai, Matteo; Holmström, Margareta; Schulman, Sam
2017-02-28
The optimal timing of vitamin K antagonists (VKAs) resumption after an upper gastrointestinal (GI) bleeding, in patients with continued indication for oral anticoagulation, is uncertain. We included consecutive cases of VKA-associated upper GI bleeding from three hospitals retrospectively. Data on the bleeding location, timing of VKA resumption, recurrent GI bleeding and thromboembolic events were collected. A model was constructed to evaluate the 'total risk', based on the sum of the cumulative rates of recurrent GI bleeding and thromboembolic events, depending on the timing of VKA resumption. A total of 121 (58 %) of 207 patients with VKA-associated upper GI bleeding were restarted on anticoagulation after a median (interquartile range) of one (0.2-3.4) week after the index bleeding. Restarting VKAs was associated with a reduced risk of thromboembolism (HR 0.19; 95 % CI, 0.07-0.55) and death (HR 0.61; 95 % CI, 0.39-0.94), but with an increased risk of recurrent GI bleeding (HR 2.5; 95 % CI, 1.4-4.5). The composite risk obtained from the combined statistical model of recurrent GI bleeding, and thromboembolism decreased if VKAs were resumed after three weeks and reached a nadir at six weeks after the index GI bleeding. On this background we will discuss how the disutility of the outcomes may influence the decision regarding timing of resumption. In conclusion, the optimal timing of VKA resumption after VKA-associated upper GI bleeding appears to be between 3-6 weeks after the index bleeding event but has to take into account the degree of thromboembolic risk, patient values and preferences.
Fischer, Quentin; Huisse, Marie-Geneviève; Voiriot, Guillaume; Caron, Claudine; Lepage, Laurent; Dilly, Marie-Pierre; Nataf, Patrick; Ajzenberg, Nadine; Kirsch, Matthias
2015-01-01
Bleeding originating in the gastrointestinal (GI) tract is one of the most common adverse events after left ventricular assist device (LVAD) implantation. In these patients, GI bleeding appears to be the consequence of altered hemostasis on the one hand and alterations of the GI microvasculature on the other. We report the case of a patient who suffered repeated, severe GI bleeding early after implantation of a HeartMate II continuous-flow LVAD. After failure of conventional treatment strategies, GI bleeding was controlled using repeated transfusions of a purified von Willebrand factor (VWF) concentrate, almost devoid of Factor VIII (Wilfactin, LFB). No episodes of pump thrombosis were noted. Subsequent to VWF transfusions, we observed a progressive normalization of circulating vascular endothelial growth factor levels. Our data raise the possibility that, in addition to its hemostatic properties, transfusions of VWF might have acted as an antiangiogenic factor. © 2014 AABB.
DOT National Transportation Integrated Search
1978-03-01
This report deals with the selection of a test site, the design of a test installation, equipment selection, the installation and start-up of a pneumatic pipeline system for the transportation of tunnel muck. A review of prior pneumatic applications ...
Web-Based Learning and Instruction Support System for Pneumatics
ERIC Educational Resources Information Center
Yen, Chiaming; Li, Wu-Jeng
2003-01-01
This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…
Hardee, Harry C.
1991-01-01
A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.
A high resolution pneumatic stepping actuator for harsh reactor environments
NASA Astrophysics Data System (ADS)
Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.
1993-01-01
A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Benjamin, E-mail: BenjaminMiller@nyc.rr.com; Spertus, Juliette, E-mail: Juliette.Spertus@gmail.com; Kamga, Camille, E-mail: CKamga@UTRC2.org
Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems havemore » been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more or less over the long-term. These findings point to the local factors that will determine the relative economic and environmental costs and benefits in specific situations.« less
2009-01-01
Additionally, high-speed air bearings have been demonstrated in micromotors (55 000 rpm) and micro-turbomachinery (2 million rpm) [7, 8]. While...without thrust balances [11]. For applications requiring continuous rotation ( micromotors and micropumps) this hydrostatic balancing force can be...conditions for stable actuation of the micromotor leading to maximum speeds. In addition to increased speed, this device demonstrates a substantial
Gastrointestinal Bleeding Following LVAD Placement from Top to Bottom.
Cushing, Kelly; Kushnir, Vladimir
2016-06-01
Left ventricular assist devices (LVADs) are an increasingly prevalent form of mechanical support for patients with end-stage heart failure. These devices can be implanted both as a bridge to transplant and as definitive/destination therapy. Gastrointestinal (GI) bleeding is one of the most common and recalcitrant long-term complications following LVAD implantation, with an incidence approaching 30 %. This review will discuss what is known about the pathophysiology of GI bleeding in LVADs and the currently available options for medical and/or endoscopic management. The pathophysiology of bleeding is multifactorial, with hemodynamic alterations, acquired von Willebrand factor deficiency, and coagulopathy being most often implicated. The majority of bleeding events in this population result from angioectasias and gastroduodenal erosive disease. While these bleeding events are significant and often require transfusion therapy, they are rarely life threatening. Endoscopy remains the standard of care with upper endoscopy offering the highest diagnostic yield in these patients. However, the effectiveness of endoscopic hemostasis in this population is not well established. A small number of studies have evaluated medical therapy and alterations in LVAD settings as a means of preventing or treating bleeding with variable results. In summary, GI bleeding with LVADs is a common occurrence and will continue to be as more LVADs are being performed for destination therapy.
Obstetric bleeding among women with inherited bleeding disorders: a retrospective study.
Hawke, L; Grabell, J; Sim, W; Thibeault, L; Muir, E; Hopman, W; Smith, G; James, P
2016-11-01
Women with inherited bleeding disorders are at increased risk for bleeding complications during pregnancy and the postpartum period, particularly postpartum haemorrhage (PPH). This retrospective study evaluates pregnancy management through the Inherited Bleeding Disorders Clinic of Southeastern Ontario, the clinical factors associated with pregnancy-related abnormal bleeding and assesses tranexamic acid use in the postpartum treatment of bleeding disorder patients. A chart review of 62 pregnancies, from 33 women, evaluated patient characteristics (age, haemostatic factor levels) and delivery conditions (mode of delivery, postpartum treatment) in relation to abnormal postpartum bleeding. This cohort revealed increased risk of immediate PPH with increased age at delivery (mean age: 30.1 years with PPH, 26.5 years without PPH, P < 0.013), and birth by vaginal delivery (P < 0.042). Low von Willebrand factor (VWF) antigen or factor VIII (FVIII) in the third trimester was not associated with an increased risk of PPH; however, low VWF:RCo was associated with increased immediate PPH despite treatment with continuous factor infusion (P < 0.042). Women treated with tranexamic acid postpartum had less severe bleeding in the 6-week postpartum (P < 0.049) with no thrombotic complications. This study contributes to the growing body of work aimed at optimizing management of bleeding disorder patients through pregnancy and the postpartum period, showing patients are at a higher risk of PPH as they age. Risk factors such as low third trimester VWF:RCo have been identified. Treatment with tranexamic acid in the postpartum period is associated with a reduced incidence of abnormal postpartum bleeding. © 2016 John Wiley & Sons Ltd.
Kobayashi, Norihiro; Yamawaki, Masahiro; Nakano, Masatsugu; Hirano, Keisuke; Araki, Motoharu; Takimura, Hideyuki; Sakamoto, Yasunari; Mori, Shinsuke; Tsutsumi, Masakazu; Ito, Yoshiaki
2016-11-15
No scoring system for evaluating the bleeding risk of atrial fibrillation (AF) patients after drug-eluting stent (DES) implantation with triple antithrombotic therapy (TAT) is available. We aimed to develop a new scoring system for predicting bleeding complications in AF patients after DES implantation with TAT. Between April 2007 and April 2014, 227 AF patients undergoing DES implantation with TAT were enrolled. Bleeding incidence defined as Bleeding Academic Research Consortium criteria≥2 was investigated and predictors of bleeding complications were evaluated using multivariate analysis. Bleeding complications occurred in 58 patients (25.6%) during follow-up. Multivariate analysis revealed dual antiplatelet therapy (DAPT) continuation (OR 3.33, P=0.01), age>75 (OR 2.14, P=0.037), international normalized ratio>2.2 (OR 5.82, P<0.001), gastrointestinal ulcer history (OR 3.06, P=0.037), and anemia (OR 2.15, P=0.042) as predictors of major bleeding complications. A score was created using the weighted points proportional to the beta regression coefficient of each variable. The DAIGA score showed better predictive ability for bleeding complications than the HAS-BLED score (AUC: 0.79 vs. 0.62, P=0.0003). Bleeding incidence was well stratified: 17.8% in low-risk (scores 0-1), 55.5% in moderate-risk (2-3), and 83.0% in high-risk (4-7) patients (P<0.001). This scoring system is useful for predicting bleeding complications and risk stratification of AF patients after DES implantation with TAT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier
2017-01-01
Introduction Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. Methods and analysis This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. Ethics and dissemination This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Trial registration Clinical Trials NCT02534974 PMID:28790042
Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier
2017-08-07
Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Clinical Trials NCT02534974. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Davidson, B J
1986-10-01
There is no simple and rapid test available to predict the outcome of an early pregnancy complicated by vaginal bleeding. In this prospective study, 15 women with normal pregnancies collected a weekly urine sample between 6 and 13 weeks' gestation. A single random urine sample was obtained from 15 women with bleeding who continued to carry their child and 50 women who proceeded to have a spontaneous abortion (SAB). Pregnandiol-3-glucuronide (PDG) was determined with the use of enzyme-multiplied immunoassay technique (EMIT) and estrone conjugates (E1C) were measured by radioimmunoassay (RIA). The ratios of these metabolites to creatinine (C) were calculated. PDG/C ratios in normal women rose gradually from 6 weeks on. All women with bleeding during a normal pregnancy had ratios in the normal range, but 94% of women with a SAB had ratios below the normal range. The E1C/C ratio remained unchanged from 6 to 11 weeks and then rose rapidly. Until 11 weeks, there was no clear separation between the E1C/C ratios of the women with a SAB and the women with bleeding who continued their pregnancies. The prognosis of threatened abortion can be made by a urinary PDG/C ratio but not by an E1C/C ratio. EMIT is simple and quick and uses technology present in many laboratories.
Long-term left ventricular assist device use before transplantation.
Sapirstein, J S; Pae, W E; Aufiero, T X; Boehmer, J P; Pierce, W S
1995-01-01
Between September 1992 and April 1995, 19 patients at the authors' institution received pneumatic, pulsatile left ventricular assist devices (LVADs) for bridging to cardiac transplantation. The mean (+/- SD) age of the patients was 51 +/- 14 years (range, 19-64 years). Nine (47%) patients had end-stage idiopathic cardiomyopathy, five (26%) had ischemic cardiomyopathy, and five (26%) other recipients were in cardiogenic shock caused by acute myocardial infarction (AMI). Fifteen (79%) patients were supported with an intraaortic balloon pump or centrifugal LVAD at the time of LVAD insertion (duration, 5.5 +/- 4.1 days). Aprotinin was given to limit bleeding; heparin, followed by warfarin sodium, was used for anticoagulation. A vigorous exercise and nutrition protocol was followed. Cardiac index averaged 2.94 +/- 0.87 L/min/m2 immediately after the implantation procedure. No patient required placement of a right VAD. Average duration of LVAD support was 45 +/- 39 days (range, 3-153 days). Major complications included bleeding requiring reoperation (three patients); cerebrovascular accident (three patients); and severe dysrhythmias requiring direct current cardioversion (four patients). Fourteen (74%) patients underwent transplantation, with one patient still being mechanically supported. All of the patients receiving transplants were discharged from the hospital. Of the individuals who died while supported with the LVAD, 75% were patients with AMI. Timely application of LVADs as part of the interdisciplinary management of end-stage heart disease has generated excellent results for transplant candidates. Right ventricular dysfunction has not necessitated right VAD placement in the authors' experience. Patients with AMI have a higher risk of death while being supported with the device than do more chronically ill recipients.
Sphenoid sinus types, dimensions and relationship with surrounding structures.
Štoković, Nikola; Trkulja, Vladimir; Dumić-Čule, Ivo; Čuković-Bagić, Ivana; Lauc, Tomislav; Vukičević, Slobodan; Grgurević, Lovorka
2016-01-01
The human sphenoid sinus is an extremely variable cavity and an important landmark in hypophyseal surgery. The aim of this study was to investigate the relationship between the sphenoid sinus type, size, extent of pneumatization and occurrence of protrusions of the adjacent neurovascular structures. A total of 51 randomly selected skulls (≥20 years of age, 33 male; 102 sinuses) were analyzed using cone beam computed tomography to estimate pneumatization extension beyond the body of the sphenoid (planum sphenoidale, pterygoid process, greater wings, clivus, dorsum sellae) and protrusions of the maxillary, mandibular, optic or pterygoid nerve or the internal carotid artery. Difference in pneumatization type between the left and the right-sided sinus was observed in 45% of the skulls. Conchal pneumatization was registered in 2%, presellar in 24%, sellar in 41% and postsellar in 33% of total sinuses. Presellar sinuses frequently pneumatized planum sphenoidale and sporadically other structures, and were characterized by sporadic optic nerve protrusions. Sellar and particularly postsellar sinuses were characterized by simultaneous pneumatization extensions and neurovascular protrusions. In the case of postsellar-type sinuses, the probability of these multiple interactions was not affected by their actual size, while it increased with the increasing sinus dimensions in the case of sellar-type sinuses. A more detailed analysis indicated that increasing sinus height, length or width increased the probability of interactions and pneumatization of particular surrounding structures. Data suggest that the sphenoid sinus pneumatization type and dimensions might be used to estimate the risks of iatrogenic injury during transsphenoidal surgical procedures. Copyright © 2015 Elsevier GmbH. All rights reserved.
Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo
2017-08-08
Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.
21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.
Code of Federal Regulations, 2010 CFR
2010-04-01
... surgical drill. 874.4250 Section 874.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH....4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 6 2011-10-01 2011-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.
Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong
2018-06-20
The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.
Application of Model-based Prognostics to a Pneumatic Valves Testbed
NASA Technical Reports Server (NTRS)
Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George
2014-01-01
Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.
Hicks, Rodney W; Denholm, Bonnie
2013-10-01
Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integrity. Perioperative nurses should be familiar with the indications, contraindications, and changes in physiology associated with pneumatic tourniquet use. The revised AORN "Recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures" is focused on the perioperative nurse's role in patient care and provides guidance for developing, implementing, and evaluating practices that promote patient safety and improve the likelihood of positive outcomes. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.
Kim, Hyung Jin; Seo, Yeong Ho
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. To the left are several pneumatic panels. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
New antithrombotic agents in the ambulatory setting.
Gibbs, Neville M; Weightman, William M; Watts, Stephen A
2014-12-01
Many patients presenting for surgical or other procedures in an ambulatory setting are taking new antiplatelet or anticoagulant agents. This review assesses how the novel features of these new agents affect the management of antithrombotic therapy in the ambulatory setting. There have been very few studies investigating the relative risks of continuing or ceasing new antithrombotic agents. Recent reviews indicate that the new antithrombotic agents offer greater efficacy or ease of administration but are more difficult to monitor or reverse. They emphasize the importance of assessing the bleeding risk of the procedure, the thrombotic risk if the agent is ceased, and patient factors that increase the likelihood of bleeding. The timing of cessation of the agent, if required, depends on its pharmacokinetics and patients' bleeding risks. Patients at high risk of thrombotic complications may require bridging therapy. Once agreed upon, the perioperative plan should be made clear to all involved. As there are few clinical studies to guide management, clinicians must make rational decisions in relation to continuing or ceasing new antithrombotic agents. This requires knowledge of their pharmacokinetics, and a careful multidisciplinary assessment of the relative thrombotic and bleeding risks in individual patients.
Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina
2012-10-01
Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. Copyright © 2012 Elsevier Ltd. All rights reserved.
A New Type of Motor: Pneumatic Step Motor
Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis
2011-01-01
This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106
Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy
2012-12-14
The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices. Copyright © 2012. Published by Elsevier B.V.
Hemorrhoids screening and treatment prior to LVAD: is it a necessity?
Skouri, Hadi; Shurrab, Mohammed; Zahnan, Jad; Deeba, Samer; Sfeir, Pierre; Gharzuddin, Walid; Haj-Yahia, Saleem
2016-04-12
Continuous-flow left ventricle assist devices (CF-LVADs) has become an essential modality in the management of stage D heart failure (HF) with significant improvement in survival and quality of life. Due to the durability of such devices and long term support complications such as bleeding and aortic insufficiency has emerged. Bleeding accounts for more than 20 % with the majority being from the gastrointestinal tract. The increase of bleeding tendency are mainly attributed to the loss of large von Willebrand's Factor (vWF) multimers due to shear stress with the chronic intake of anticoagulants. We are reporting two cases of patients with Stage D HF and history of hemorrhoids presenting for LVAD implantation. Many efforts that decrease bleeding related to CF-LVADs will be discussed with focus on hemorrhoids.
NASA Astrophysics Data System (ADS)
Kapralov, S. V.; Shapkin, Y. G.; Lychagov, V. V.; Tuchin, V. V.
2007-05-01
One of the most complex problems of emergency surgery is the choice of surgical tactics to deal with bleeding peptic ulcer. Endoscopic hemostasis is prescribed to patients with continuing bleedings and prerelapse syndrome. But till nowdays the objective verification of the prerelapse condition had not been worked out. What is more there are no objective criteria to judge the effectiveness of the carried endohemostasis. The aim of the study was to work out a new objective diagnostic method of pre-recurrence syndrome that can be able to make prognosis for possible gastroduodenal ulcer bleeding recurrence more precise. Laser Doppler flowmetry was the method of studies the regional perfusion. The device used in this work was made at the Optics and Biophysics Department of Saratov State University.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-01
...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of..., Office 6, ``Administrative Review of the Countervailing Duty Order on Certain New Pneumatic Off-the-road...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
...-the-Road Tires From the People's Republic of China: Extension of Preliminary Results of Antidumping... for the preliminary results of the administrative review of certain new pneumatic off-the-road tires... on certain new pneumatic off-the-road tires from the PRC. See Initiation of Antidumping and...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-pneumatic tire assembly incorporates a wheel, supports the tire, and attaches, either integrally or... directly or through a wheel or wheel center member, the vertical load and tractive forces from the roadway... assembly means a non-pneumatic tire, alone or in combination with a wheel or wheel center member, which can...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-04
... DEPARTMENT OF COMMERCE International Trade Administration (A-570-912) New Pneumatic Off-the-Road.... EFFECTIVE DATE: August 4, 2010. FOR FURTHER INFORMATION CONTACT: Andrea Staebler Berton or Raquel Silva, AD... review of the antidumping duty order on new pneumatic off-the-road tires (``OTR tires'') from the People...
Benagiano, Giuseppe; Carrara, Sabina; Filippi, Valentina
2009-01-01
The progestational steroid norgestrel was synthesized and tested between 1960 and 1965 through an international cooperation between Wyeth, USA and Schering, Berlin. It is a mixture of two “enantiomers,” with only one form (designated as levonorgestrel) biologically active. When taken orally, it is rapidly absorbed, not subjected to a “first-pass” effect and is approximately 90% bioavailable, with a circulating half-life around 15 hours. Its contraceptive action is exerted at the central (hypothalamic) and peripheral (cervical mucus and endometrium) levels. Levonorgestrel (LNG), alone or in combination with ethinyl estradiol (EE), is the most widely employed contraceptive progestin: it is used in combined oral contraceptives, progestogen-only pills, long-acting contraceptive implants, intrauterine contraceptive systems and in emergency contraception. It is also the steroid of choice for new oral contraceptive regimens aimed at reducing the frequency of bleeding episodes. This novel approach, already tried more than 30 years ago, gained interest around the year 2000 when surveys of women’s attitudes toward monthly menstrual bleeding started to show a major change: more and more women declared that they would welcome a hormonal contraceptive method that reduced bleeding episodes to 4, 2 or even 1 per year. At this point, while the debate on the significance and “usefulness” of menstruation went on, attention focused on new regimens. The first new modality consisted of changing the 7-day medication-free interval, either shortening it to fewer than 7 days, or by the administration of low-dose estrogens during the interval between packages. Then, continuous administration regimens started to be investigated. This, however, did not happen suddenly, since, in specific situations, doctors had for years empirically utilized various continuous administration regimens. The first extended-cycle oral contraceptive regimen introduced in clinical practice is an 84-day regimen that results in bleeding only 4 times a year. A commercial product specifically packed for continuous use is now available in Europe and contains 30 μg EE and 150 μg LNG. In a variation of this regimen, after administration of the same combination for 84 days, women are given 7 pills containing 10 μg EE. A 6-monthly regimen has also been tested in a small study using EE 20 μg plus LNG 100 μg taken with and without a hormone-free interval. Women in the continuous group reported significantly fewer bleeding days requiring protection and were more likely to have amenorrhea; in addition they also reported significantly fewer days of bloating and menstrual pain. A yearly regimen is now being developed. Each pill of this novel formulation contains EE 20 μg and LNG 90 μg to be taken continuously for 364 days (13 cycles) per year. A phase III trial has now evaluated safety, efficacy and menses inhibition. At the end of the 1-year trial amenorrhea was present in 58.7% of the women and a complete absence of bleeding in 79.0%. Overall, the number of bleeding and spotting days per pill pack declined with time and adverse events and discontinuations were comparable to those reported for cyclic oral contraceptive regimens. PMID:19936155
Castilloux, Jean Francois; Moffat, Karen A; Liu, Yang; Seecharan, Jodi; Pai, Menaka; Hayward, Catherine P M
2011-10-01
Light transmission platelet aggregometry (LTA) is important to diagnose bleeding disorders. Experts recommend testing LTA with native (N) rather than platelet count adjusted (A) platelet-rich plasma (PRP), although it is unclear if this provides non-inferior, or superior, detection of bleeding disorders. Our goal was to determine if LTA with NPRP is non-inferior to LTA with APRP for bleeding disorder assessments. A prospective cohort of patients, referred for bleeding disorder testing, and healthy controls, were evaluated by LTA using common agonists, NPRP and APRP (adjusted to 250 x 10⁹ platelets/l). Recruitment continued until 40 controls and 40 patients with definite bleeding disorders were tested. Maximal aggregation (MA) data were assessed for the detection of abnormalities from bleeding disorders (all causes combined to limit bias), using sample-type specific reference intervals. Areas under receiver-operator curves (AUROC) were evaluated using pre-defined criteria (area differences: < 0.15 for non-inferiority, > 0 for superiority). Forty-four controls and 209 patients were evaluated. Chart reviews for 169 patients indicated 67 had bleeding disorders, 28 from inherited platelet secretion defects. Mean MA differences between NPRP and APRP were small for most agonists (ranges, controls: -3.3 to 5.8; patients: -3.0 to 13.7). With both samples, reduced MA with two or more agonists was associated with a bleeding disorder. AUROC differences between NPRP and APRP were small and indicated that NPRP were non-inferior to APRP for detecting bleeding disorders by LTA, whereas APRP met superiority criteria. Our study validates using either NPRP or APRP for LTA assessments of bleeding disorders.
Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems
Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.
2016-09-20
An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.
Throttle pneumatic impact mechanism equipped with afterburner idle-stroke chamber
NASA Astrophysics Data System (ADS)
Dedov, Alexey; Frantseva, Eleanor; Dmitriev, Mikhail
2017-01-01
Pneumatic impact mechanisms are widely used in construction, mining and other economic sectors of a country. Such mechanisms are a base for a wide range of machines of various types and dimensions from hand-held tools to mounted piling hammers with impact energy up to 10 000 J. This paper is aimed at creation of pneumatic impact mechanism with the improved characteristics, including operation, energy use, weight and size which is especially important in space-limited working conditions. The research methods include development of computer mathematical model that can solve equations system and test a prototype model at the experimental stand. As a result of conducted research the pneumatic impact mechanism with the improved characteristics was developed. An engineering method for calculating throttle pneumatic impact mechanisms with a preset value of impact energy from 1 to 20 000 was investigated. This method allows creating percussive machines of a wide range of application.
Imparting Motion to a Test Object Such as a Motor Vehicle in a Controlled Fashion
NASA Technical Reports Server (NTRS)
Southward, Stephen C. (Inventor); Reubush, Chandler (Inventor); Pittman, Bryan (Inventor); Roehrig, Kurt (Inventor); Gerard, Doug (Inventor)
2014-01-01
An apparatus imparts motion to a test object such as a motor vehicle in a controlled fashion. A base has mounted on it a linear electromagnetic motor having a first end and a second end, the first end being connected to the base. A pneumatic cylinder and piston combination have a first end and a second end, the first end connected to the base so that the pneumatic cylinder and piston combination is generally parallel with the linear electromagnetic motor. The second ends of the linear electromagnetic motor and pneumatic cylinder and piston combination being commonly linked to a mount for the test object. A control system for the linear electromagnetic motor and pneumatic cylinder and piston combination drives the pneumatic cylinder and piston combination to support a substantial static load of the test object and the linear electromagnetic motor to impart controlled motion to the test object.
Rupp, Rüdiger; Plewa, Harry; Schuld, Christian; Gerner, Hans Jürgen; Hofer, Eberhard P; Knestel, Markus
2011-02-01
In incomplete spinal cord injured subjects, task-oriented training regimes are applied for enhancement of neuroplasticity to improve gait capacity. However, a sufficient training intensity can only be achieved during the inpatient phase, which is getting shorter and shorter due to economic restrictions. In the clinical environment, complex and expensive robotic devices have been introduced to maintain the duration and the intensity of the training, but up to now only a few exist for continuation of automated locomotion training at home. For continuation of the automated locomotion training at home prototypes of the compact, pneumatically driven orthosis MoreGait have been realized, which generate the key afferent stimuli for activation of the spinal gait pattern generator. Artificial pneumatic muscles with excellent weight-to-force ratio and safety characteristics have been integrated as joint actuators. Additionally, a Stimulative Shoe for generation of the appropriate foot loading pattern has been developed without the need for verticalization of the user. The first results of the pilot study in eight chronic incomplete spinal cord injured subjects indicate that the home-based therapy is safe and feasible. The therapy related improvements of the walking capacity are in the range of locomotion robots used in clinical settings.
Floroff, Catherine K; Rieger, Krista L; Veasey, Tara M; Strout, Sara E; DeNino, Walter F; Meadows, Holly B; Stroud, Martha R; Toole, John M; Heyward, Dawn P; Brisco-Bacik, Meredith A; Cook, Jennifer L; Lazarchick, John; Uber, Walter E
Pump thrombosis (PT) is a severe complication of left ventricular assist device (LVAD) support. This study evaluated PT and bleeding after LVAD placement in patients responsive to a standard aspirin dose of 81 mg using platelet inhibition monitoring compared with initial nonresponders who were then titrated upward to achieve therapeutic response. Patients ≥ 18 years of age with initial placement of HeartMate II LVAD at our institution and at least one VerifyNow Aspirin test performed during initial hospitalization were included. The primary endpoints were bleeding and PT compared between initial aspirin responders and nonresponders. Of 85 patients, 19 (22%) were nonresponsive to initial aspirin therapy. Responders and nonresponders showed similar survival (p = 0.082), freedom from suspected/confirmed PT (p = 0.941), confirmed PT (p = 0.273), bleeding (p = 0.401), and incidence rates in PT and bleeding. Among the initial responders (<500 vs. 500-549 aspirin reaction units), there were no significant differences in survival (p = 0.177), freedom from suspected/confirmed PT (p = 0.542), confirmed PT (p = 0.159), bleeding (p = 0.879), and incidence of PT and bleeding. Platelet function testing may detect resistance to standard aspirin regimens used in LVAD patients. Dose escalation in initially nonresponsive patients to achieve responsiveness may confer a similar PT risk to patients initially responsive to standard aspirin dosing without increased bleeding risk.
Yoshihashi, Kazutaka; Takeda, Minako; Kitazawa, Takehisa; Soeda, Tetsuhiro; Igawa, Tomoyuki; Sampei, Zenjiro; Kuramochi, Taichi; Sakamoto, Akihisa; Haraya, Kenta; Adachi, Kenji; Kawabe, Yoshiki; Nogami, Keiji; Shima, Midori; Hattori, Kunihiro
2014-01-01
ACE910 is a humanized anti-factor IXa/X bispecific antibody mimicking the function of factor VIII (FVIII). We previously demonstrated in nonhuman primates that a single IV dose of ACE910 exerted hemostatic activity against hemophilic bleeds artificially induced in muscles and subcutis, and that a subcutaneous (SC) dose of ACE910 showed a 3-week half-life and nearly 100% bioavailability, offering support for effective prophylaxis for hemophilia A by user-friendly SC dosing. However, there was no direct evidence that such SC dosing of ACE910 would prevent spontaneous bleeds occurring in daily life. In this study, we newly established a long-term primate model of acquired hemophilia A by multiple IV injections of an anti-primate FVIII neutralizing antibody engineered in mouse-monkey chimeric form to reduce its antigenicity. The monkeys in the control group exhibited various spontaneous bleeding symptoms as well as continuous prolongation of activated partial thromboplastin time; notably, all exhibited joint bleeds, which are a hallmark of hemophilia. Weekly SC doses of ACE910 (initial 3.97 mg/kg followed by 1 mg/kg) significantly prevented these bleeding symptoms; notably, no joint bleeding symptoms were observed. ACE910 is expected to prevent spontaneous bleeds and joint damage in hemophilia A patients even with weekly SC dosing, although appropriate clinical investigation is required. PMID:25274508
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-912] New Pneumatic Off-the-Road... the initiation of a new shipper review of the antidumping duty order on new pneumatic off-the-road... Off-the-Road Tires from the People's Republic of China: Initiation of New Shipper Review, 74 FR 56575...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
...-the-Road Tires From the People's Republic of China: Rescission of Antidumping Duty Administrative... order on certain new pneumatic off-the-road tires from the People's Republic of China (``PRC'') for the... antidumping duty order on certain new pneumatic off-the-road tires, with respect to the above-named companies...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-11
...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of... withdrawal of its request for review. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... Tires From the People's Republic of China: Extension of Time Limit for Final Results of Countervailing... administrative review of the countervailing duty order on certain new pneumatic off-the-road tires from the People's Republic of China. See New Pneumatic Off-the-Road Tires From the People's Republic of China...
Treatment of hemorrhagic gastritis by antacid.
Simonian, S J; Curtis, L E
1976-10-01
A simple and safe method of nonsurgical treatment for the control of massive acute gastric mucosal hemorrhage is described. The procedure was developed from experimental and clinical observations that the presence of gastric hydrocloric acid played an important part in the development and perpetuation of the entity. The treatment consists of complete neutralization of gastric acid with antacid to a pH of 7. The antacid is intermittently added and aspirate at 7. In a retrospective analysis, the hemorrhage was controlled in 44 of 49 patients (89%). Five patients who continued to bleed underwent surgery (10%). Three patients had vagotomy and pyloroplasty and their bleeding ceased without recurrence. Two patients underwent partial gastrectomy, but they developed recurrent bleeding and died. One patient whose bleeding has been controlled by vagotomy and pyloroplasty died without hemorrhage 10 days after operation. Of the 44 patients whose bleeding had been controlled by antacid, 11 patients died without hemorrhage one or more weeks later. These results of 89% control of hemorrhage compare favorably with those in the literature.
Treatment of hemorrhagic gastritis by antacid.
Simonian, S J; Curtis, L E
1976-01-01
A simple and safe method of nonsurgical treatment for the control of massive acute gastric mucosal hemorrhage is described. The procedure was developed from experimental and clinical observations that the presence of gastric hydrocloric acid played an important part in the development and perpetuation of the entity. The treatment consists of complete neutralization of gastric acid with antacid to a pH of 7. The antacid is intermittently added and aspirate at 7. In a retrospective analysis, the hemorrhage was controlled in 44 of 49 patients (89%). Five patients who continued to bleed underwent surgery (10%). Three patients had vagotomy and pyloroplasty and their bleeding ceased without recurrence. Two patients underwent partial gastrectomy, but they developed recurrent bleeding and died. One patient whose bleeding has been controlled by vagotomy and pyloroplasty died without hemorrhage 10 days after operation. Of the 44 patients whose bleeding had been controlled by antacid, 11 patients died without hemorrhage one or more weeks later. These results of 89% control of hemorrhage compare favorably with those in the literature. PMID:13746
Removal of unburned carbon from coal fly ash using a pneumatic triboelectrostatic separator.
Kim, J K; Cho, H C; Kim, S C
2001-01-01
A pneumatic triboelectrostatic beneficiation system of fly ash was studied using a continuous, bench-scale electroseparator composed of two vertical electrode plates and an ejector-tribocharger. Tests were conducted to evaluate the charge density and the separation efficiency at various operating conditions. It was found that the higher charge densities were obtained at (1) the air flow rate of 1.75 m3/min. (2) the feed rate of less than 50 kg/h. and (3) the relative humidity of less than 30% with use of a stainless ejector tribocharger. With these optimum conditions, the clean ash of less than LOI 3% was recovered with a yield over 75% when operated at the diffuser slit gap of 4mm, the diffuser outlet velocity of 16.1-18.6 m/s, and the distance of 15 cm between diffuser slit and splitter. The optimum feed rate was found to be 740 kg/h per m2 of electrode surface area, which can be used as a scale-up factor of electroseparator.
Labenz, J; Peitz, U; Leusing, C; Tillenburg, B; Blum, A L; Börsch, G
1997-01-01
BACKGROUND: In healthy subjects, continuous infusions of high dose ranitidine and omeprazole produce high intragastric pH values. AIM: To test the hypothesis that both drugs also maintain high intragastric pH values in patients with bleeding ulcers. PATIENTS AND METHODS: In two parallel studies, 20 patients with bleeding duodenal ulcers and 20 patients with bleeding gastric ulcers were randomly assigned to receive either ranitidine (0.25 mg/kg/hour after a bolus of 50 mg) or omeprazole (8 mg/hour after a bolus of 80 mg) for 24 hours. Intragastric pH was continuously recorded with a glass electrode placed 5 cm below the cardia. RESULTS: Both drugs rapidly raised the intragastric pH above 6. During the second 12 hour period, however, the percentage of time spent below a pH of 6 was 0.15% with omeprazole and 20.1% with ranitidine (p = 0.0015) in patients with duodenal ulcer; in patients with gastric ulcer it was 0.1% with omeprazole and 46.1% with ranitidine (p = 0.002). CONCLUSIONS: Primed infusions of omeprazole after a bolus produced consistently high intragastric pH values in patients with bleeding peptic ulcers, whereas primed infusions with ranitidine were less effective during the second half of a 24 hour treatment course. This loss of effectiveness may be due to tolerance. PMID:9155573
Development of Pneumatic Robot Hand and Construction of Master-Slave System
NASA Astrophysics Data System (ADS)
Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori
Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.
Gutierrez, E; Huang, Y; Haglid, K; Bao, F; Hansson, H A; Hamberger, A; Viano, D
2001-03-01
Rapid head rotation is a major cause of brain damage in automobile crashes and falls. This report details a new model for rotational acceleration about the center of mass of the rabbit head. This allows the study of brain injury without translational acceleration of the head. Impact from a pneumatic cylinder was transferred to the skull surface to cause a half-sine peak acceleration of 2.1 x 10(5) rad/s2 and 0.96-ms pulse duration. Extensive subarachnoid hemorrhages and small focal bleedings were observed in the brain tissue. A pronounced reactive astrogliosis was found 8-14 days after trauma, both as networks around the focal hemorrhages and more diffusely in several brain regions. Astrocytosis was prominent in the gray matter of the cerebral cortex, layers II-V, and in the granule cell layer and around the axons of the pyramidal neurons in the hippocampus. The nuclei of cranial nerves, such as the hypoglossal and facial nerves, also showed intense astrocytosis. The new model allows study of brain injuries from head rotation in the absence of translational influences.
Sulak, Patricia J; Carl, Jenny; Gopalakrishnan, Isai; Coffee, Andrea; Kuehl, Thomas J
2004-10-01
To evaluate in a clinical practice setting the acceptance, continuation and variability of extending the active interval of oral contraceptives (OCs) with introduction of a shortened hormone-free interval (HFI) to manage breakthrough bleeding. A retrospective review was undertaken of patients seen by one obstetrician/gynecologist and counseled on extending the active interval of OCs with a shortened HFI of 3-4 days to manage bleeding. Electronic medical records were searched for the phrase "extending the number of active pills" for patients counseled between January 1, 2000, and January 31, 2003, with follow-up through January 31, 2004. A structured query of each patient's initial and follow-up records was performed. The 220 patients counseled on the extended regimen were 14-52 years of age (mean 36.4, SD 9.3 years). At initial counseling before extending, the majority of patients cited more than one reason for using OCs in the standard fashion with 59% using OCs for noncontraceptive reasons. Reasons for extending the active interval of OCs included premenstrual symptoms (45%), dysmenorrhea/pelvic pain (40%), heavy withdrawal bleeding (36%), menstrual associated headaches (35%), convenience (13%), acne associated with menses (10%) and other (15%). Of the 181 patients with follow-up data, 174 (96%) attempted an extended regimen with 121 (67%) continuing to do so at last follow-up. Follow-up intervals ranged from 0.3 to 3.8 years (mean 1.6 years). Using Kaplan-Meier product limit survival analysis, 60% of patients continued using extended patterns of OCs for more than 2 years. For 121 currently extending, the HFI varied from 0 to 7 days with 88% utilizing a 0 to 4 day HFI. Sixty percent of patients offered extending the active interval and shortening the HFI of OCs initiate and continue this pattern for more than 2 years without serious sequelae or pregnancy while individually directing both the number of days of continuous pills and the length of the HFI. Copyright 2004 Elsevier Inc.
NASA Astrophysics Data System (ADS)
Tang, T. F.; Chong, S. H.
2017-06-01
This paper presents a practical controller design method for ultra-precision positioning of pneumatic artificial muscle actuator stages. Pneumatic artificial muscle (PAM) actuators are safe to use and have numerous advantages which have brought these actuators to wide applications. However, PAM exhibits strong non-linear characteristics, and these limitations lead to low controllability and limit its application. In practice, the non-linear characteristics of PAM mechanism are difficult to be precisely modeled, and time consuming to model them accurately. The purpose of the present study is to clarify a practical controller design method that emphasizes a simple design procedure that does not acquire plants parameters modeling, and yet is able to demonstrate ultra-precision positioning performance for a PAM driven stage. The practical control approach adopts continuous motion nominal characteristic trajectory following (CM NCTF) control as the feedback controller. The constructed PAM driven stage is in low damping characteristic and causes severe residual vibration that deteriorates motion accuracy of the system. Therefore, the idea to increase the damping characteristic by having an acceleration feedback compensation to the plant has been proposed. The effectiveness of the proposed controller was verified experimentally and compared with a classical PI controller in point-to-point motion. The experiment results proved that the CM NCTF controller demonstrates better positioning performance in smaller motion error than the PI controller. Overall, the CM NCTF controller has successfully to reduce motion error to 3µm, which is 88.7% smaller than the PI controller.
First Approach of Pneumatic Anthropomorphic Hand
2001-10-25
1 o f 3 FIRST APPROACH OF PNEUMATIC ANTHROPOMORPHIC HAND Jiménez, Omar; Leija, Lorenzo; Muñoz, Roberto Centro de Investigación y de Estudios...weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1 . INTRODUCTION...The projects have been guided through an specific line of development. The project MARCUS[ 1 ] includes easiness as the most important aspect what
System for Dispensing a Precise Amount of Fluid
Benett, William J.; Krulevitch, Peter A.; Visuri, Steven R.; Dzenitis, John M.; Ness, Kevin D.
2008-08-12
A dispensing system delivers a precise amount of fluid for biological or chemical processing and/or analysis. Dispensing means moves the fluid. The dispensing means is operated by a pneumatic force. Connection means delivers the fluid to the desired location. An actuator means provides the pneumatic force to the dispensing means. Valving means transmits the pneumatic force from the actuator means to the dispensing means.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
...-the-Road Tires From the People's Republic of China: Notice of Second Extension of Time Limit for the... duty order on certain new pneumatic off-the-road tires (``off-the-road tires'') from the People's... on off- the-road tires from the PRC. See Certain New Pneumatic Off-the-Road Tires from the People's...
Benson, Roger B J; Butler, Richard J; Carrano, Matthew T; O'Connor, Patrick M
2012-02-01
Pneumatic (air-filled) postcranial bones are unique to birds among extant tetrapods. Unambiguous skeletal correlates of postcranial pneumaticity first appeared in the Late Triassic (approximately 210 million years ago), when they evolved independently in several groups of bird-line archosaurs (ornithodirans). These include the theropod dinosaurs (of which birds are extant representatives), the pterosaurs, and sauropodomorph dinosaurs. Postulated functions of skeletal pneumatisation include weight reduction in large-bodied or flying taxa, and density reduction resulting in energetic savings during foraging and locomotion. However, the influence of these hypotheses on the early evolution of pneumaticity has not been studied in detail previously. We review recent work on the significance of pneumaticity for understanding the biology of extinct ornithodirans, and present detailed new data on the proportion of the skeleton that was pneumatised in 131 non-avian theropods and Archaeopteryx. This includes all taxa known from significant postcranial remains. Pneumaticity of the cervical and anterior dorsal vertebrae occurred early in theropod evolution. This 'common pattern' was conserved on the line leading to birds, and is likely present in Archaeopteryx. Increases in skeletal pneumaticity occurred independently in as many as 12 lineages, highlighting a remarkably high number of parallel acquisitions of a bird-like feature among non-avian theropods. Using a quantitative comparative framework, we show that evolutionary increases in skeletal pneumaticity are significantly concentrated in lineages with large body size, suggesting that mass reduction in response to gravitational constraints at large body sizes influenced the early evolution of pneumaticity. However, the body size threshold for extensive pneumatisation is lower in theropod lineages more closely related to birds (maniraptorans). Thus, relaxation of the relationship between body size and pneumatisation preceded the origin of birds and cannot be explained as an adaptation for flight. We hypothesise that skeletal density modulation in small, non-volant, maniraptorans resulted in energetic savings as part of a multi-system response to increased metabolic demands. Acquisition of extensive postcranial pneumaticity in small-bodied maniraptorans may indicate avian-like high-performance endothermy. © 2011 The Authors. Biological Reviews © 2011 Cambridge Philosophical Society.
Vaughan Sarrazin, Mary S; Jones, Michael; Mazur, Alexander; Chrischilles, Elizabeth; Cram, Peter
2014-12-01
Clinical trial data suggest that dabigatran and warfarin have similar rates of major bleeding but higher rates of gastrointestinal bleeding. These findings have not been evaluated outside of a clinical trial. We evaluated the relative risks of any, gastrointestinal, intracranial, and other bleeding for Veterans Affairs patients who switched to dabigatran after at least 6 months on warfarin, compared with patients who continued on warfarin. We used national Veterans Affairs administrative encounter and pharmacy data from fiscal years 2010-2012 to identify 85,344 patients with atrial fibrillation who had been taking warfarin for at least 180 days before June 2011, of whom 1394 (1.7%) received dabigatran (150 mg) during the next 15 months. Dates of the first occurrence of each type of bleed and dates of death from June 2011 to September 2012 were determined. Baseline and time-dependent patient characteristics were identified, including comorbid conditions, stroke and bleeding risk scores, and time in therapeutic range for international normalized ratios. Marginal structural models were used to address selection bias in the longitudinal observational data. Weighted logistic regression models were fit using generalized estimating equations and reflected baseline and time-dependent covariates and weekly indicators of anticoagulant type (warfarin or dabigatran). Compared with patients who never used dabigatran, patients who used dabigatran at least once were younger, were more likely to be white, had lower international normalized ratio time in therapeutic range on warfarin, had lower stroke risk scores, and had similar bleeding risk scores. Overall, 10,734 patients experienced bleeding events, including 131 events after dabigatran use. The risk-adjusted rate of any bleeding was higher with dabigatran compared with warfarin, which was largely driven by a 54% higher risk of gastrointestinal bleeding with dabigatran. Rates of intracranial, other bleeding, and death were similar for dabigatran and warfarin. Dabigatran may increase the likelihood of gastrointestinal bleeds. Published by Elsevier Inc.
Hite, Nathan; Klinger, Aaron L; Miller, Peter; Beck, David E; Whitlow, Charles B; Hicks, Terry C; Green, Heather M; Margolin, David A
2018-09-01
The incidence of postprocedural bleeding in patients undergoing rubber band ligation (RBL) for symptomatic internal hemorrhoids while taking clopidogrel bisulfate is unknown. To determine the postprocedural bleeding risk of RBL for patients taking clopidogrel compared with age- and sex-matched controls. This is a retrospective case-controlled cohort study analyzing data from 2005 to 2013 conducted at a single tertiary care academic center. The study included a total of 80 rubber bands placed on 41 patients taking clopidogrel bisulfate and 72 bands placed on 41 control patients not taking clopidogrel matched for age and sex. The 30-d rates of significant and insignificant bleeding events after RBL were recorded. A bleeding event was considered significant if the patient required admission to the hospital, transfusion of blood products, or additional procedures to stop the bleeding. Insignificant bleeding was defined as passage of blood or clots per rectum with spontaneous cessation and no need for additional intervention. There was no significant difference in the number of bleeding events per band placed in the clopidogrel group when compared with the control group (3.75% versus 2.78%, P = 0.7387). The rate of significant (2.5% versus 1.39%, P = 0.6244) and insignificant bleeding events (1.25% versus 1.39%, P = 0.9399) was also similar between the two groups. Two significant bleeding events occurred in the clopidogrel group requiring intervention: cauterization in one patient and colonoscopy and transfusion in the other. The risk of a bleeding complication after RBL for hemorrhoids does not appear to be increased in patients taking clopidogrel. Our results support the practice of continuing clopidogrel bisulfate in the periprocedural period as the associated risk of thrombosis is greater than the risk of bleeding. Copyright © 2018 Elsevier Inc. All rights reserved.
Kataoka, Toshiyuki; Hoshi, Keika; Ando, Tomohiro
2016-01-01
Objective Unexpected post-extraction bleeding is often experienced in clinical practice. Therefore, determining the risk of post-extraction bleeding in patients receiving anticoagulant therapy prior to surgery is beneficial. This study aimed to verify whether the HAS-BLED score was useful in predicting post-extraction bleeding in patients taking warfarin. Design Retrospective cohort study. Setting Department of Oral and Maxillofacial Surgery, Tokyo Women's Medical University. Participants Participants included 258 sequential cases (462 teeth) who had undergone tooth extraction between 1 January 2010 and 31 December 2012 while continuing warfarin therapy. Main outcome measure Post-extraction risk factors for bleeding. The following data were collected as the predicting variables for multivariate logistic analysis: the HAS-BLED score, extraction site, tooth type, stability of teeth, extraction procedure, prothrombin time-international normalised ratio value, platelet count and the use of concomitant antiplatelet agents. Results Post-extraction bleeding was noted in 21 (8.1%) of the 258 cases. Haemostasis was achieved with localised haemostatic procedures in all the cases of post-extraction bleeding. The HAS-BLED score was found to be insufficient in predicting post-extraction bleeding (area under the curve=0.548, p=0.867, multivariate analysis). The risk of post-extraction bleeding was approximately three times greater in patients taking concomitant oral antiplatelet agents (risk ratio=2.881, p=0.035, multivariate analysis). Conclusions The HAS-BLED score alone could not predict post-extraction bleeding. The concomitant use of oral antiplatelet agents was a risk factor for post-extraction bleeding. No episodes of post-extraction bleeding required more than local measures for haemostasis. However, because this was a retrospective study conducted at a single institution, large-scale prospective cohort studies, which include cases of outpatient tooth extraction, will be necessary in the future. PMID:26936909
Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide
NASA Astrophysics Data System (ADS)
Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun
2014-07-01
This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.
Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.
Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun
2014-07-01
This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.
The qualitative assessment of pneumatic actuators operation in terms of vibration criteria
NASA Astrophysics Data System (ADS)
Hetmanczyk, M. P.; Michalski, P.
2015-11-01
The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.
Tests of two new polyurethane foam wheelchair tires.
Gordon, J; Kauzlarich, J J; Thacker, J G
1989-01-01
The performance characteristics of four 24-inch wheelchair tires are considered; one pneumatic and three airless. Specifically, two new airless polyurethane foam tires (circular and tapered cross-section) were compared to both a molded polyisoprene tire and a rubber pneumatic tire. Rolling resistance, coefficient of static friction, spring rate, tire roll-off, impact absorption, wear resistance, and resistance to compression set were the characteristics considered for the basis of comparison. Although the pneumatic tire is preferred by many wheelchair users, the two new polyurethane foam tires were found to offer a performance similar to the high-pressure pneumatic tire. In addition, the foam tires are less expensive and lighter in weight than the other tires tested.
Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.
1990-01-01
Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.
Analytical Solution to the Pneumatic Transient Rod System at ACRR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fehr, Brandon Michael
2016-01-08
The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validatedmore » against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.« less
Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.
Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin
2017-09-20
Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.
Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators
NASA Astrophysics Data System (ADS)
Miao, Yu; Dong, Wei; Du, Zhijiang
2017-11-01
Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.
High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces
NASA Technical Reports Server (NTRS)
Miller, Thomas W.
1995-01-01
Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.
Inexpensive Dramatic Pneumatic Lift
NASA Astrophysics Data System (ADS)
Morse, Robert A.
2017-09-01
Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article describes the construction and use of an inexpensive hand-held pneumatic lift to demonstrate the same principle.
Kozachenko, I N
2016-01-01
The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons remains to be developed. The objective of the present work was to elaborate the classification of the injuries caused by gunshots from the pneumatic weapons based on the analysis of 98 expert and acts of forensic medical expertises (surveys) of living subjects (n=76) and corpses (n=22) affected by gunshots from the pneumatic weapons. These materials were collected from the bureaus of forensic medical expertise in different regions of the Ukraine during the period from 2006 till 2015. In addition, scientific publications concerned with the problem of interest were used along with the relevant explanatory and terminological dictionaries. The terminology and the conceptual framework proposed by the author in the earlier papers provided a basis for the development of the first standard classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons categorized into 15 groups. It is believed that this classification will lay the foundation for the common approach of forensic medical experts to the examination and analysis of the data on the gunshots from the pneumatic weapons used to be found on the bodies of living subjects and the corpses. Moreover, it may be useful for the clinicians in their diagnostic and therapeutic practices and for the legal practitioners engaged in the quality assessment of the results of forensic medical expertises. It is recommended to present information about the gunshots from the pneumatic weapons in the accounting documents in a separate line.
Paulus, David C; Schilling, Brian K
2009-01-01
The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. Four previously trained men (mean +/- SD; age = 20+/-2 years, body mass = 99+/-18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. The pneumatic resistance GRF (N; mean +/- SD) was 749+/-114 on the left leg and 786+/-123 on the right leg and the free weight GRF was 786+/-114 left and 861+/-111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.
Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction.
Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton
2015-01-01
Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03-2.13). Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction.
Use of pneumatic lithotripsy for managing difficult CBD calculi.
Farooq Qadri, Syed Javid; Khan, Muneer; Khan, Naveed
2011-01-01
About 7-12% of patients who harbor gallbladder calculi concomitant common bile duct (CBD) calculi are present. The treatment of gallbladder calculi has standardized in the form of laparoscopic cholecystectomy but management of CBD calculi is still evolving. Endoscopic removal of CBD calculi <2 cm in diameter is successful in 90-100% of cases but patients harboring stones >2 cm in diameter high failure rates can be seen. Traditionally, laparoscopically one can achieve success rate comparable to endoscopic surgery but large and impacted calculi may cause failures. If one uses pneumatic lithotripsy during laparoscopic management of CBD calculi one can achieve 100% stone clearance irrespective of size, degree of hardness and impaction. This study evaluates the feasibility of using pneumatic lithotripsy for CBD calculi. To our knowledge this is the 1st reported series of using pneumatic lithotripsy for CBD calculi. From June 2002 to June 2010 96 laparoscopic CBD explorations (LCBDE) were done for CBD calculi. Patients having choledocholithiasis with CBD diameter of >10 mm were taken for LCBDE while in patients with CBD diameter of <10 mm were referred for endoscopic clearance. Additionally ERCP failure cases were also subjected to LCBDE. Rigid nephroscope was used for LCBDE and usually calculi were removed by forceps only. In patients having large, hard &/or impacted calculi pneumatic lithotripsy were used for fragmentation. Out of the 96 patients in 12 (12.5%) cases pneumatic lithotripsy was used for stone fragmentation. Out of these 12 cases 5 (41.6%) were ERCP failure cases. At a mean hospital stay of 2.5 days 100% stone clearance was achieved in all cases with no perioperative complication. The present study shows how successfully pneumatic lithotripsy can be used to fragment large, hard &/or impacted CBD calculi. Pneumatic lithotripsy being user friendly easily available can reliably fragment CBD calculi in one session. Copyright © 2010 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Low, Jin-Huat; Yeow, Chen-Hua
2016-08-02
Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.
Chiang, Mao-Hsiung; Lin, Hao-Ting
2011-01-01
This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control.
Chiang, Mao-Hsiung; Lin, Hao-Ting
2011-01-01
This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot’s end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H∞ tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control. PMID:22247676
Amani, Mohammad; Fazlollahi, Narges; Shirani, Shapour; Malekzadeh, Reza; Mikaeli, Javad
2016-01-01
BACKGROUND Although Heller myotomy is one of the most effective treatments for achalasia, it may be associated with early or late symptom relapse in some patients. Therefore, additional treatment is required to achieve better control of symptoms. To evaluate the safety and efficacy of pneumatic balloon dilation (PBD) in patients with symptom relapse after Heller myotomy. METHODS Thirty six post-myotomy patients were evaluated from 1993 to 2013. Six patients were excluded from the analysis because of comorbid diseases or epiphrenic diverticula. Thirty patients were treated with PBD. Primary outcome was defined as a decrease in symptom score to 4 or less and a reduction greater than 80% from the baseline in the volume of barium in timed barium esophagogram in 6 weeks. Achalasia symptom score (ASS) was assessed at 1.5, 3, 6, and 12 months after treatment and then every six months in all patients and PBD was repeated in case of symptom relapse (ASS>4). RESULTS The mean age of the patients was 45.5±13.9 years (range: 21-73). Primary outcome was observed in 25 patients (83%). The mean ASS of the patients dropped from 7.8 before treatment to 1.3±2.0 at 1.5 months after treatment (p=0.0001). The mean volume and height of barium decreased from 43.1±33.4 and 7.1±4.7 to 6.0±17.1 and 1.1±2.2, respectively (p=0.003, p=0.003). The mean duration of follow-up was 11.8±6.3 years. At the end of the study, 21 patients (70%) reported sustained good response. No major complications such as perforation or gross bleeding were seen. CONCLUSION PBD is an effective and safe treatment option for achalasia in patients with symptom relapse after Heller myotomy.
Kwak, Hong Suk; Cho, Jai Ho; Kim, Jung Taek; Yoo, Jeong Joon
2017-01-01
Background Venous thromboembolism (VTE) is a relatively common and potentially life threatening complication after major hip surgery. There are two main types of prophylaxis: chemical and mechanical. Chemical prophylaxis is very effective but causes bleeding complications in surgical wounds and remote organs. On the other hand, mechanical methods are free of hemorrhagic complications but are less effective. We hypothesized that mechanical prophylaxis is effective enough for Asians in whom VTE occurs less frequently. This study evaluated the effect of intermittent pneumatic compression (IPC) in the prevention of VTE after major hip surgery. Methods Incidences of symptomatic VTE after primary total hip arthroplasty with and without application of IPC were compared. A total of 379 patients were included in the final analysis. The IPC group included 233 patients (106 men and 127 women) with a mean age of 54 years. The control group included 146 patients (80 men and 66 women) with a mean age of 53 years. All patients took low-dose aspirin for 6 weeks after surgery. IPC was applied to both legs just after surgery and maintained all day until discharge. When a symptom or a sign suspicious of VTE, such as swelling or redness of the foot and ankle, Homans' sign, and dyspnea was detected, computed tomography (CT) angiogram or duplex ultrasonogram was performed. Results Until 3 months after surgery, symptomatic VTE occurred in three patients in the IPC group and in 6 patients in the control group. The incidence of VTE was much lower in the IPC group (1.3%) than in the control group (4.1%), but the difference was not statistically significant. Complications associated with the application of IPC were not detected in any patient. Patients affected by VTE were older and hospitalized longer than the unaffected patients. Conclusions The results of this study suggest that IPC might be an effective and safe method for the prevention of postoperative VTE. PMID:28261425
Pneumatic fracturing of low permeability media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuring, J.R.
1996-08-01
Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.
High-pressure portable pneumatic drive unit.
Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y
1989-12-01
The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.
Pneumatic Regolith Transfer Systems for In Situ Resource Utilization
NASA Technical Reports Server (NTRS)
Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack
2010-01-01
This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.
Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei
2008-07-01
An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.
Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles
NASA Astrophysics Data System (ADS)
Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel
2018-03-01
The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles
Chapin, John; Bamme, Jaqueline; Hsu, Fraustina; Christos, Paul; DeSancho, Maria
2017-03-01
Adults with hemophilia A (HA), hemophilia B (HB), and von Willebrand disease (VWD) frequently require surgery and invasive procedures. However, there is variability in perioperative management guidelines. We describe our periprocedural outcomes in this setting. A retrospective chart review from January 2006 to December 2012 of patients with HA, HB, and VWD undergoing surgery or invasive procedures was conducted. Type of procedures, management including the use of continuous factor infusion, and administration of antifibrinolytics were reviewed. Adverse outcomes were defined as acute bleeding (<48 hours), delayed bleeding (≥48 hours), transfusion, inhibitor development, and thrombosis. We identified 59 patients with HA and HB. In all, 24 patients had severe hemophilia and 12 had mild/moderate hemophilia. Twelve patients had inhibitors. There were also 5 female carriers of HA and 6 patients with VWD. There were 34 major surgeries (26 orthopedic, 8 nonorthopedic) and 129 minor surgeries. Continuous infusion was used in 55.9% of major surgeries versus 8.5% of minor surgeries. Antifibrinolytics were administered in 14.7% of major surgeries versus 23.2% of minor surgeries. In all, 4 patients developed acute bleeding and 10 patients developed delayed bleeding. Delayed bleeding occurred in 28.6% of genitourinary procedures and in 16.1% of dental procedures. Five patients acquired an inhibitor and 2 had thrombosis. In conclusion, patients with HA, HB, or VWD had similar rates of adverse outcomes when undergoing minor surgeries or major surgeries. This finding underscores the importance of an interdisciplinary management and procedure-specific guidelines for patients with hemophilia and VWD prior to even minor invasive procedures.
Recht, Michael; Neufeld, Ellis J; Sharma, Vivek R; Solem, Caitlyn T; Pickard, A Simon; Gut, Robert Z; Cooper, David L
2014-09-01
There is limited understanding of the effects of bleeding episodes on the daily lives of patients with congenital hemophilia with inhibitors and their caregivers. This analysis of the Dosing Observational Study in Hemophilia examined the impact of acute bleeding episodes on work, school, and family activities. Patients and caregivers participated in a diary study for 90 or more days or until patients experienced four bleeding episodes. All bleed treatments, interference with daily activities, and quality-of-life assessments were captured in daily records. Patients and caregivers reported planned workdays or school days eligible to be "lost" so as to differentiate from days lost because of disability or nonworking status, weekends, and vacations. Diaries were completed for 39 patients (18 adults and 21 children). Bleeding episodes that continued for 3 or more days (16.4%) accounted for most of the major changes to family plans. For the 38 patients with bleeding episodes, 47% of 491 bleed days fell on planned workdays or school days; the remainder fell on weekends, holidays, or nonworkdays or non-school days and therefore did not count as "lost days." Patients reported a loss of productivity on a greater percentage of eligible bleed days than did caregivers (3.9% vs. 0.8%, respectively). Patients and caregivers reported 13.5%/9.3% fully missed and 3.5%/7.6% partially missed days. This study demonstrated that in hemophilia with inhibitors, bleeding episodes interfere with the daily activities of patients and their caregivers. Furthermore, documenting only lost days underestimated the impact of bleeding episodes because of the high percentage of days without planned work or school. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Heikinheimo, O; Inki, P; Kunz, M; Gemzell-Danielsson, K
2010-06-01
Consecutive use of the levonorgestrel-releasing intrauterine system (LNG-IUS) is increasing. However, little is known about factors that predict the bleeding during consecutive use. The objective of this study was to analyse the possible factors which may predict the bleeding pattern during the first year of use of a second LNG-IUS. Fertile-aged women (n = 204) who had used their first LNG-IUS for over 4 years and who opted for a second LNG-IUS were recruited. Bleeding data were reported using 90-day reference periods (RPs) starting from the last 90 days of the first LNG-IUS use (baseline), until the end of the first year of the second LNG-IUS (RPs 1-4). Demographic factors such as age, parity, body mass index, indication of LNG-IUS use or smoking could not be identified as predictors for bleeding and spotting (B/S). Mean (+/-SD) number of B/S days was 8.9 (+/-9.1) at baseline. This increased slightly during RP1 and fell to 6.4 (+/-8.1) during RP4. Compared with the mean, women with uterine fibroids or a bleeding pattern of >9 days of spotting or any bleeding at RP1 had more B/S days during RP1-4. Although the number of B/S days decreased progressively from RP1 to RP4 in the group with a bleeding pattern of >9 days of spotting or any bleeding at baseline, such a phenomenon was not observed for women with fibroids. The difference for the change in B/S days between women with and without fibroids was statistically significant at RP3 and RP4. A high degree (91.7%) of satisfaction with the bleeding pattern was observed, with amenorrhoeic women being most satisfied. Uterine B/S is reduced during consecutive use of the LNG-IUS. Women with uterine fibroids or any bleeding at baseline continued to have more B/S than other women.
Sørdal, Terje; Inki, Pirjo; Draeby, John; O'Flynn, Mary; Schmelter, Thomas
2013-05-01
To assess the efficacy of tranexamic acid or mefenamic acid in the management of the initial "nuisance" bleeding or spotting in the period immediately after placement of the levonorgestrel-releasing intrauterine system. Women were randomized after levonorgestrel-releasing intrauterine system placement to oral tranexamic acid (500 mg), mefenamic acid (500 mg), or placebo three times daily during bleeding or spotting episodes over a 90-day treatment period. Treatment was initiated from onset of a bleeding or spotting episode and continued until the first day after bleeding or spotting stopped and restarted with a new bleeding or spotting episode. The primary efficacy variable was reduction in the number of bleeding or spotting days. Tranexamic acid and mefenamic acid were compared with placebo using a one-sided Wilcoxon rank-sum test. Bonferroni-Holm adjustment was used to account for multiple testing. A total of 204 women were screened; 187 were randomized to tranexamic acid (n=63), mefenamic acid (n=63), or placebo (n=61). The median number of bleeding or spotting days experienced during treatment was 25, 29, and 33 days in the three groups, respectively. The median number of bleeding or spotting days was reduced by 6 days (95% confidence interval [CI] -14.0 to 1.0, P=.049) with tranexamic acid and by 3 days (95% CI -11.0 to 5.0, P=.229) with mefenamic acid compared with placebo. The relative risk of bleeding or spotting compared with placebo with tranexamic acid and mefenamic acid was 0.82 (95% CI 0.65-1.03) and 0.89 (95% CI 0.71-1.11), respectively. Most women (85% or more) were satisfied with the levonorgestrel-releasing intrauterine system across the groups. Tranexamic acid and mefenamic acid during the first 90 days after levonorgestrel-releasing intrauterine system placement do not alleviate "nuisance" bleeding or spotting. ClinicalTrials.gov, www.clinicaltrials.gov, NCT01295294. I.
Loor, Gabriel; Vivacqua, Alessandro; Sabik, Joseph F; Li, Liang; Hixson, Eric D; Blackstone, Eugene H; Koch, Colleen G
2013-11-01
High-performing health care organizations differentiate themselves by focusing on continuous process improvement initiatives aimed at enhancing patient outcomes. Reoperation for bleeding is an event associated with considerable morbidity risk. Hence, our primary objective was to develop and implement a formal operative checklist to reduce technical reasons for postoperative bleeding. From January 1, 2011, through June 30, 2012, 5812 cardiac surgical procedures were performed at Cleveland Clinic (Cleveland, OH). A multidisciplinary team developed a simple, easy-to-perform hemostasis checklist based on the most common sites of bleeding. An extensive educational in-service was performed before limited, then universal, checklist implementation. Geometric charts were used to track the number of cases between consecutive reoperations for bleeding. We compared these before (phase 0) and after the first limited implementation phase (phase 1) and the universal implementation phase (phase 2) of the checklist. The average number of cases between consecutive reoperations for bleeding increased from 32 in phase 0 to 53 in both phase 1 (P = .002) and phase 2 (P = .01). A substantial reduction in reoperation for bleeding cases followed implementation of a formalized hemostasis checklist. Our findings underscore the important influence of memory aids that focus attention on surgical techniques to improve patient outcomes in a complex, operative work environment. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Bush, Sean P; Seifert, Steven A; Oakes, Jennifer; Smith, Susan D; Phan, Tammy H; Pearl, Sarah R; Reibling, Ellen T
2013-07-01
In patients bitten by North American rattlesnakes and treated with Crotalidae Polyvalent Immune Fab (Ovine) (FabAV), late hematologic abnormalities-persistent, recurrent, or late, new onset of hypofibrinogenemia, prolonged PT/INR, prolonged PTT, and/or thrombocytopenia beyond 48 h post-envenomation-are common, difficult to manage, and may result in morbidity and mortality are common, difficult to manage, and may result in morbidity and mortality. The optimal management of late hematologic abnormalities, particularly the use of further treatment with antivenom, has not been well defined. The current FabAV treatment regimen is to give antivenom as a bolus dose over a one-hour period. We describe our experience using a continuous intravenous infusion of FabAV for late hematologic effects and/or associated bleeding complications in rattlesnake envenomation. This is a retrospective, observational case series of patients envenomated by North American rattlesnakes at three medical centers managed with a continuous intravenous infusion of FabAV for late hematologic abnormalities and/or associated bleeding complications. Indications, dilution and infusion protocols, and duration of therapy were individualized. Five cases were identified between July 2010 and September 2011. All patients had profound late hematologic abnormalities and/or were associated with bleeding complications. Several patients had received repeat bolus infusions of FabAV, with or without human blood products, with either inadequate or only transient beneficial response. All patients were then managed with a continuous intravenous infusion of FabAV and all appeared to respond to the continuous intravenous infusion of FabAV, titrated to effect, with cessation of progression and, in most cases, improvement in hematologic abnormalities. Rates of infusion varied from 2 to 4 vials per 24 h (mean = 3.1 ± 0.4 vials/day). The termination of FabAV infusion was between day 6 and day 14 from the time of envenomation (mean = 10 ± 3 days), after which hematologic values were normalized or were normalizing in all patients and continued to do so. The use of FabAV as a continuous intravenous infusion, particularly after the acute phase of envenomation has passed, provides a continuous source of circulating antibodies to neutralize venom components reaching circulation from tissue stores and allows natural replenishment of hematologic factors such as platelets and/or fibrinogen. This method is an efficient use of FabAV, avoiding the wasteful excess of a bolus dose, may be more effective, eliminating the potential for destruction of hematologic factors when protective antivenom levels are lost between bolus FabAV doses, and appears to be safe. Further assessments of the stability and sterility of the product during infusion are needed. The need to continue hospitalization is the major drawback, but continued observation and inpatient care may be needed for other indications (e.g. bleeding) in this subset of patients. A continuous intravenous infusion of FabAV between 2 and 4 vials per day, titrated to effect, and continued for 6-14 days post-envenomation appeared to be associated with reversal of late hematologic effects of rattlesnake envenomation and, when combined with indicated human blood products, control of significant bleeding. Continuous intravenous infusion of FabAV may be safer, more efficacious, and more cost-effective than observation without FabAV treatment or as-needed bolus dosing in selected patients with late hematologic abnormalities. Copyright © 2013 Elsevier Ltd. All rights reserved.
Miyata, Naoko; Isaka, Mitsuhiro; Kojima, Hideaki; Maniwa, Tomohiro; Takahashi, Shoji; Takamiya, Osamu; Ohde, Yasuhisa
2016-03-01
Inherited factor VII (FVII) deficiency is a rare recessive inherited coagulation disorder with limited available information, especially in patients undergoing major thoracic surgery. In addition, an optimal management strategy for the disease has not been defined. We herein report a case involving a 61-year-old man with asymptomatic FVII deficiency who underwent a right middle and lower lobectomy to treat lung cancer. To the best of our knowledge, the present report is the first to describe the use of recombinant activated FVII continuous infusion for bleeding control after a major thoracic surgery in a patient with inherited FVII deficiency.
Small bowel enteroscopy and intraoperative enteroscopy for obscure gastrointestinal bleeding.
Lewis, B S; Wenger, J S; Waye, J D
1991-02-01
Intraoperative endoscopy (IOE) is accepted as the ultimate diagnostic procedure for completely evaluating the small bowel in patients with obscure gastrointestinal (GI) bleeding. Small bowel enteroscopy (SBE) has been reported useful in the nonsurgical evaluation of the small intestine in these patients, but findings may be limited because of incomplete small bowel intubation and a lack of tip deflection. Twenty-three patients underwent 25 SBE exams and subsequently had 25 IOE exams during surgical exploration for continued bleeding. Patients' bleeding histories averaged 2 yr, with an average transfusion requirement of 27 units. Findings on IOE were the same as with SBE in 17/22 (77%) of examinations. We conclude that SBE and IOE are comparable in depth of insertion and ability to detect small vascular ectasias. Both procedures missed pathology due to limited visibility and the evanescent nature of ectasias. Long-term success in abolishing bleeding with these combined techniques can be expected in 55% of these patients. SBE should precede surgery, since the finding of diffuse ectasias precludes any benefit from operative intervention.
Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients.
Gurvits, Grigoriy E; Fradkov, Elena
2017-06-14
Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, postoperative and nonsurgical bleeding. A significant number of left ventricular assist devices (LVAD) recipients may experience recurrent gastrointestinal hemorrhage, mainly due to combination of antiplatelet and vitamin K antagonist therapy, activation of fibrinolytic pathway, acquired von Willebrand factor deficiency, and tendency to develop small intestinal angiodysplasias due to increased rotary speed of the pump. Gastrointestinal bleeding in LVAD patients remains a source of increased morbidity including the need for blood transfusions, extended hospital stays, multiple readmissions, and overall mortality. Management of gastrointestinal bleeding in LVAD patients involves multidisciplinary approach in stabilizing the patients, addressing risk factors and performing structured endoluminal evaluation with focus on upper gastrointestinal tract including jejunum to find and eradicate culprit lesion. Medical and procedural intervention is largely successful and universal bleeding cessation occurs in transplanted patients.
Endoscopic treatment of chronic radiation proctopathy.
Wilson, Sydney A; Rex, Douglas K
2006-09-01
Chronic radiation proctopathy is a complication of pelvic radiation therapy. The acute phase of radiation injury to the rectum occurs during or up to 3 months following radiation. Acute radiation injury can continue into a chronic phase or chronic radiation proctopathy may develop after a latent period of several months or years. Symptoms associated with the condition include diarrhea, rectal pain, bleeding, tenesmus, and stricture formation. Of the various symptoms, only bleeding from radiation-induced telangiectasias is amenable to endoscopic therapy. This paper summarizes the findings of experts in the field on endoscopic treatment of bleeding from chronic radiation proctopathy. Medical management is generally ineffective in controlling bleeding from chronic radiation proctopathy. Surgical intervention has a high incidence of morbidity. Promising advances have been made in endoscopic therapy, including formalin, neodymium/yttrium aluminum garnet, argon and potassium titanyl phosphate laser treatments, as well as argon plasma coagulation. Argon plasma coagulation presents an effective, efficient, inexpensive and reasonably safe noncontact method for destruction of radiation telangiectasias. Based on currently available data and trends, argon plasma coagulation is the favored treatment for bleeding from chronic radiation proctopathy.
NASA Technical Reports Server (NTRS)
Rebeske, John J , Jr; Rohlik, Harold E
1953-01-01
An analytical investigation was made to determine from component performance characteristics the effect of air bleed at the compressor outlet on the acceleration characteristics of a typical high-pressure-ratio single-spool turbojet engine. Consideration of several operating lines on the compressor performance map with two turbine-inlet temperatures showed that for a minimum acceleration time the turbine-inlet temperature should be the maximum allowable, and the operating line on the compressor map should be as close to the surge region as possible throughout the speed range. Operation along such a line would require a continuously varying bleed area. A relatively simple two-step area bleed gives only a small increase in acceleration time over a corresponding variable-area bleed. For the modes of operation considered, over 84 percent of the total acceleration time was required to accelerate through the low-speed range ; therefore, better low-speed compressor performance (higher pressure ratios and efficiencies) would give a significant reduction in acceleration time.
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
Park, Sangik; Shin, Ji Hoon; Gwon, Dong-Il; Kim, Hyoung Jung; Sung, Kyu-Bo; Yoon, Hyun-Ki; Ko, Gi-Young; Ko, Heung Kyu
2017-07-01
To evaluate outcomes of transcatheter arterial embolization (TAE) for gastric cancer-related gastrointestinal (GI) bleeding and factors associated with successful TAE and improved survival after TAE. This retrospective study included 43 patients (34 men; age 60.6 y ± 13.6) with gastric cancer-related GI bleeding undergoing angiography between January 2000 and December 2015. Clinical course, laboratory findings, and TAE characteristics were reviewed. Technical success of TAE was defined as target area devascularization, and clinical success was defined as bleeding cessation with hemodynamic stability during 72 hours after TAE. Student t test was used for comparison of continuous variables, and Fisher exact test was used for categorical variables. Univariate and multivariate analysis were performed to identify predictors of successful TAE and 30-day survival after TAE. TAE was performed in 40 patients. Technical and clinical success rates of TAE were 85.0% and 65.0%, respectively. Splenic infarction occurred in 2 patients as a minor complication. Rebleeding after TAE occurred in 7 patients. Death related to bleeding occurred in 5 patients. Active bleeding (P = .044) and higher transfusion requirement (3.3 U ± 2.6 vs 1.8 U ± 1.7; P = .039) were associated with TAE failure. Successful TAE predicted improved 30-day survival after TAE on univariate and multivariate analysis (P = .018 and P = .022; odds ratio, 0.132). TAE for gastric cancer-associated GI bleeding may be a lifesaving procedure. Severe bleeding with a higher transfusion requirement and active bleeding on angiography predicted TAE failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Colucci, G; Giabbani, E; Barizzi, G; Urwyler, N; Alberio, L
2011-08-01
ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient. Single centre study with 30 normal volunteers. Two whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM(®) devices and compared. Connection between central laboratory, emergency and operating rooms was established using local area network. All collected ROTEM(®) parameters were within normal limits. No statistically significant differences between normal transport and pneumatic delivery were observed. Real-time transmission of the original ROTEM(®) curves using local area network is feasible and easy to establish. At our institution, transport of blood samples by pneumatic delivery does not influence ROTEM(®) parameters. Blood samples can be analysed centrally, and results transmitted live via virtual network computing to emergency or operating rooms. Prior to analyse blood samples centrally, the type of sample transport should be tested to exclude in vitro blood activation by local pneumatic transport system. © 2011 Blackwell Publishing Ltd.
Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.
Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly
2013-01-01
The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.
Cho, Nakwon
1980-01-01
A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.
Quigley, Alan James; Shannon, Helen
2013-01-01
Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950
Innovation-Prototype. Making hydraulic and/or pneumatic plates using 3D printing technology
NASA Astrophysics Data System (ADS)
Alexa, V.; Rațiu, S. A.; Kiss, I.; Cioată, V. G.; Rackov, M.
2018-01-01
Start 3D printing allows hydraulic and/or pneumatic plates to be obtained from a single technological process without requiring further post-production operations. 3D printing with innovative materials in a rich colour range has several advantages such as: time-saving, cost is the same for any type of plate and its reported just to volume, fast and impossible realization of hydraulic and/or pneumatic links compared to traditional and high accuracy technologies.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
Cohen, Michael N; Baumal, Caroline R
2018-05-10
To report early formation and spontaneous closure of a full-thickness macular hole that developed after successful pneumatic retinopexy in a patient who had been undergoing treatment for diabetic macular edema. Case report of a 68-year-old man with bilateral nonproliferative diabetic retinopathy who was currently undergoing anti-vascular endothelial growth factor treatment for bilateral diabetic macular edema. On presentation, visual acuity was 20/200 in the left eye, and examination revealed a bullous, macula-off retinal detachment with a single horseshoe tear at 12 o'clock in the left eye. Pneumatic retinopexy was performed followed by laser augmentation 3 days later. Three weeks postoperatively, he returned with visual acuity of 20/50 and a full-thickness macular hole in the left eye. Although he elected for initial observation, he returned 2 weeks later with visual acuity of 20/50 in both eyes and a retinal detachment with a single break at 10 o'clock in the right eye. The macular hole in the left eye had spontaneously resolved. Pneumatic retinopexy was performed to the right eye. Over 1 year after bilateral pneumatic retinopexy, his retina remains without recurrence of a macular hole in the left eye. In the early postoperative period after pneumatic retinopexy to repair a retinal detachment, a macular hole can form and spontaneously close.
Research on precise pneumatic-electric displacement sensor with large measurement range
NASA Astrophysics Data System (ADS)
Yin, Zhehao; Yuan, Yibao; Liu, Baoshuai
2017-10-01
This research mainly focuses on precise pneumatic-electric displacement sensor which has large measurement range. Under the high precision, measurement range can be expanded so that the need of high precision as well as large range can be satisfied in the field of machining inspection technology. This research was started by the analysis of pneumatic-measuring theory. Then, an gas circuit measuring system which is based on differential pressure was designed. This designed system can reach two aims: Firstly, to convert displacement signal into gas signal; Secondly, to reduce the measurement error which caused by pressure and environmental turbulence. Furthermore, in consideration of the high requirement for linearity, sensitivity and stability, the project studied the pneumatic-electric transducer which puts the SCX series pressure sensor as a key part. The main purpose of this pneumatic-electric transducer is to convert gas signal to suitable electrical signal. Lastly, a broken line subsection linearization circuit was designed, which can nonlinear correct the output characteristic curve so as to enlarge the linear measurement range. The final result could be briefly described like this: under the condition that measuring error is less than 1μm, measurement range could be extended to approximately 200μm which is much higher than the measurement range of traditional pneumatic measuring instrument. Meanwhile, it can reach higher exchangeability and stability in order to become more suitable to engineering application.
Merki-Feld, Gabriele S; Epple, Gina; Caveng, Nina; Imthurn, Bruno; Seifert, Burkhardt; Sandor, Peter; Gantenbein, Andreas R
2017-08-25
Menstrually related migraine (MRM) in the hormone-free interval (HFI) of combined hormonal contraceptives (CHC) are according to the ICHD definition also estrogen withdrawal migraines (EWH). MRMs are less responsive to acute medication. Therefore short-term prevention, initiated 1-2 days before onset of the anticipated bleeding and continued for 6 days, is recommended. Such a long prophylactic triptan use might increase the risk for medication overuse headache in women suffering in addition from non-menstrual migraines. In CHC users onset of hormone decline is predictable. It is however unknown, whether the EWHs are rather associated with onset of hormone withdrawal or onset of bleeding. Improved understanding of this relation might contribute to better define and shorten the time interval for prevention. For this observational diary-based pilot study we collected data from daily conducted headache diaries of CHC users with MRM in at least two of three cycles, visiting our clinic from 2009 to 2015. We analyzed frequency of migraines for each hormone free day, onset of migraine, onset of bleeding and the relation of migraine to onset of bleeding in the 7-day period following estrogen withdrawal. We identified in addition the onset of migraine attacks lasting more than 1 day (episodes). Forty patient charts met the inclusion criteria, what allowed us to analyze 103 cycles. The mean number of migraine days in the HFI was 2.2 ± 1.6. Migraine started typically on days 1-5 and bleeding on days 3-5. In relation to first day of bleeding, migraines started on days -1 to 4. Almost half of the migraine attacks lasted longer than 24 h, despite the use of rescue medication. MRM in CHC users starts on bleeding days -1 to 4, what differs from findings in the natural cycle. Referring to the HFI interval migraine started mostly on days 1-5. According to these data, it seems to be reasonable to initiate short-term prevention at the last day of pill use or the first day of the HFI and continue for 5 days.
Seidman, Daniel S; Yeshaya, Arie; Ber, Amos; Amodai, Ida; Feinstein, Itzhak; Finkel, Israelit; Gordon, Nina; Porat, Noga; Samuel, Dganit; Shiran-Makler, Einat; Wolman, Igal
2010-07-01
Continuous use of combined oral contraceptives is currently attracting growing interest as a means of improving menstrual related symptoms and reducing the number of bleeding days. To evaluate bleeding patterns, menstrual symptoms and quality of life with an extended 84/7 oral contraceptive regimen versus 21/7 cycles. In two consecutive run-in cycles, 30 microg ethinyl estradiol and 3 mg drospirenone tablets taken on days 1-21 were followed by a tablet-free period from days 22 to 28 of each cycle and then by two 84 day cycles of pill use with a 7 day tablet-free interval. The primary outcome was the total number of bleeding/spotting days. Secondary outcomes were severity of daily symptoms, general well-being determined by the PGWBI questionnaire, and overall treatment satisfaction. Of the 137 women invited to participate in the study 109 (aged 18-40 years) were enrolled. The number of bleeding days decreased by about one-third from a calculated 31.8 days of bleeding under a cyclic 21/7 regimen to an expected total of 21.8 days for the extended 84/7 regimen. The incidence of menorrhagia, intermenstrual bleeding, dysmenorrhea, abdominal bloating, breast tenderness, depressive moods and irritability - when compared at enrollment and at the end of the second extended study period--was significantly lower (P < 0.005) among women on the continuous pill regimen. The median (range) global PGWBI scores were not substantially different before and after the extended use cycles: 78.2 (39.1-96.4) and 77.3 (30.9-96.4), respectively. Body weight and skin condition also remained constant. At the completion of the study: 65.5% of the women were either highly satisfied (41.4%) or satisfied (24.1%) with the extended regimen. The extended 84/7 regimen was found to be satisfactory for the majority of participants and was associated with a decrease in the number of bleeding days and an improvement in menstrual symptoms compared to 21/7 cycles.
NASA Astrophysics Data System (ADS)
Qiu, Zhi-cheng; Shi, Ming-li; Wang, Bin; Xie, Zhuo-wei
2012-05-01
A rod cylinder based pneumatic driving scheme is proposed to suppress the vibration of a flexible smart beam. Pulse code modulation (PCM) method is employed to control the motion of the cylinder's piston rod for simultaneous positioning and vibration suppression. Firstly, the system dynamics model is derived using Hamilton principle. Its standard state-space representation is obtained for characteristic analysis, controller design, and simulation. Secondly, a genetic algorithm (GA) is applied to optimize and tune the control gain parameters adaptively based on the specific performance index. Numerical simulations are performed on the pneumatic driving elastic beam system, using the established model and controller with tuned gains by GA optimization process. Finally, an experimental setup for the flexible beam driven by a pneumatic rod cylinder is constructed. Experiments for suppressing vibrations of the flexible beam are conducted. Theoretical analysis, numerical simulation and experimental results demonstrate that the proposed pneumatic drive scheme and the adopted control algorithms are feasible. The large amplitude vibration of the first bending mode can be suppressed effectively.
Soft pneumatic grippers embedded with stretchable electroadhesion
NASA Astrophysics Data System (ADS)
Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.
2018-05-01
Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.
Development of a pneumatic tensioning device for gap measurement during total knee arthroplasty.
Kwak, Dai-Soon; Kong, Chae-Gwan; Han, Seung-Ho; Kim, Dong-Hyun; In, Yong
2012-09-01
Despite the importance of soft tissue balancing during total knee arthroplasty (TKA), all estimating techniques are dependent on a surgeon's manual distraction force or subjective feeling based on experience. We developed a new device for dynamic gap balancing, which can offer constant load to the gap between the femur and tibia, using pneumatic pressure during range of motion. To determine the amount of distraction force for the new device, 3 experienced surgeons' manual distraction force was measured using a conventional spreader. A new device called the consistent load pneumatic tensor was developed on the basis of the biomechanical tests. Reliability testing for the new device was performed using 5 cadaveric knees by the same surgeons. Intraclass correlation coefficients (ICCs) were calculated. The distraction force applied to the new pneumatic tensioning device was determined to be 150 N. The interobserver reliability was very good for the newly tested spreader device with ICCs between 0.828 and 0.881. The new pneumatic tensioning device can enable us to properly evaluate the soft tissue balance throughout the range of motion during TKA with acceptable reproducibility.
Multistage position-stabilized vibration isolation system for neutron interferometry
NASA Astrophysics Data System (ADS)
Arif, Muhammad; Brown, Dennis E.; Greene, Geoffrey L.; Clothier, R.; Littrell, K.
1994-10-01
A two stage, position stabilized vibration isolation system has been constructed and is now in operation at the Cold Neutron Research Facility of the National Institute of Standards and Technology, Gaithersburg, MD. The system employs pneumatic isolators with a multiple input/multiple output pneumatic servo system based upon pulse width modulation control loops. The first stage consists of a 40,000 kg reinforced concrete table supported by pneumatic isolators. A large environmentally isolated laboratory enclosure rests on the concrete table. The second stage consists of a 3000 kg granite optical table located within the enclosure and supported by another set of pneumatic isolators. The position of the two stages is monitored by proximity sensors and inclinometers with 12 degrees of freedom. The system controls 12 independent pneumatic airsprings. The signals from these sensors are fed into a personal computer based control system. The control system has maintained the position of the two stages to better than 1 micrometers in translation and 5 (mu) rad in orientation for a period of a few months. A description of the system and its characteristics is given.
Dental postoperative bleeding complications in patients with suspected and documented liver disease.
Hong, C H; Scobey, M W; Napenas, J J; Brennan, M T; Lockhart, P B
2012-10-01
The aims of this study were to determine the frequency of bleeding complications following dental procedures in patients with known or suspected chronic liver disease and whether international normalized ratio (INR) determination could aid in predicting bleeding complications in these patients. We identified 90 patients (mean age: 51 ± 9 years) in this retrospective chart review. Sixty-nine patients had a known history of chronic liver disease and 21 had suspected chronic liver disease. Descriptive statistics were determined. Independent sample t-test and one-way variance test were utilized for continuous variables and chi-square test for dichotomous variables. The mean INR value for all patients was 1.2 ± 0.3. The INR value was significantly associated with the diagnosis of liver cirrhosis, the diagnoses of Hepatitis B and C together, the presence of ascites alone, and the number of clinical signs and symptoms (i.e. ascites, jaundice and encephalopathy) present. Nine patients with INR values between 1.5 and 2 underwent invasive dental procedures without postoperative bleeding complications. There were no episodes of postoperative bleeding in patients. The findings suggest that clinicians should not rely solely on an INR value to predict post-procedure bleeding in patients with liver disease. © 2012 John Wiley & Sons A/S.
Neuhaus, J.E.
1992-10-13
A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.
Neuhaus, John E.
1992-01-01
A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.
Intramuscular pressures in antigravity muscles using gravity-independent, pneumatic hardware.
Macias, Brandon R; Minocha, Ranjeet; Cutuk, Adnan A; Hill, James; Shiau, Jonathon; Hargens, Alan R
2008-08-01
Resistive exercise helps prevent muscle atrophy in microgravity, but better exercise equipment is needed. Therefore, the purpose of this study was to determine if a pneumatic, gravity-independent leg-press device (LPD) provides sufficient force to leg musculature. We hypothesized that intramuscular pressure (IMP), a quantitative index of muscle force, is greater in the antigravity superficial posterior and deep posterior compartments than in the non-antigravity anterior compartment during bilateral leg-press exercise. Millar pressure transducers were inserted into the anterior, lateral, superficial posterior, and deep posterior muscle compartments of the left leg of eight healthy subjects (three women, five men). Subjects were supine on the Keiser SX-1, a pneumatic LPD. Then maximal voluntary contraction (MVC) was determined; each subject performed three consecutive voluntary contractions at approximately 18%, 50%, and 100% MVC while continuously measuring IMP. Repeated measures ANOVA were used to determine differences of IMPs between compartments and loads. The magnitudes of IMP (mean +/- SEM) at 18 - 3% (abbreviated approximately 18%), 50%, and 100% MVC in the superficial and deep posterior compartments were significantly greater than that in the anterior compartment during exercise (P < 0.05). Additionally, IMPs in all four compartments significantly rose as resistance increased at approximately 18%, 50%, and 100% MVC (P < 0.05). The LPD provides significantly increased resistance to all four compartments, but with greater loading of the antigravity compartments as compared to the non-antigravity compartment. Since antigravity muscles of the leg are contained primarily in the superficial and deep posterior compartments, the LPD may help prevent muscle atrophy associated with microgravity.
2015-01-01
A hybrid microchip/capillary electrophoresis (CE) system was developed to allow unbiased and lossless sample loading and high-throughput repeated injections. This new hybrid CE system consists of a poly(dimethylsiloxane) (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel, and a fused-silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused-silica capillary separation column. Analytes are rapidly separated in the fused-silica capillary, and following separation, high-sensitivity MS detection is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high-throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates, and CE separation voltages. PMID:24865952
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Ryan T.; Wang, Chenchen; Rausch, Sarah J.
2014-07-01
A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channelmore » and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.« less
Pulpotomies with CO2 laser in dogs
NASA Astrophysics Data System (ADS)
Figueiredo, Jose A. P.; Chavantes, Maria C.; Gioso, Marco A.; Pesce, Hildeberto F.; Jatene, Adib D.
1995-05-01
The aim of this study was to evaluate the clinical aspects of dental pulps submitted to shallow pulpotomy followed by CO2 laser radiation at five different procedures. For this purpose, initially 66 dogs' teeth were opened and about 2 or 3 mm of coronal dental pulp was removed. Continuous irrigation with saline solution was implemented. The teeth were randomly divided into 6 groups of 11 each. After cessation of bleeding, in group I, CO2 laser (Xanar-20, USA) was irradiated for 1 second at a power of 5 watts; in group II, 2 seconds at 3 watts; in Group III, 2 seconds at 5 watts; in Group IV, 1 second at 3 watts; in Group V, a continuous mode at 3 watts; Group VI served as a control, with no laser irradiation. The results showed no clinical differences between the 3 W and 5 W powers. Time period of irradiation exposition influenced definitively the clinical appearance of the dental pulps. Groups I and IV (1 second) were unable to stop the bleeding, which persisted over 15 minutes for all teeth. This may be due to the intense heat generated by CO2 laser, causing vasodilatation. Groups II and III displayed a similar appearance, but bleeding stopped in about 10 minutes. Group V (continuous mode) had no bleeding after irradiation, but a plasma-like liquid would come out for almost 2 minutes. When comparing to the control (Group VI), all the pulps would assume a jelly-like aspect, with black granulated tissue on the surface, covering totally the pulps of Group V and partially the other groups. The histological results will be discussed in a further study. From the data obtained, it seems that CO2 laser irradiation for pulpotomies should be done in a continuous mode, for clinical convenience in terms of time taken and effective irradiation.
Pneumatically Actuated Miniature Peristaltic Vacuum Pumps
NASA Technical Reports Server (NTRS)
Feldman, Sabrina; Feldman, Jason; Svehla, Danielle
2003-01-01
Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric pressure or to a partial vacuum source. The design would be such that the higher pneumatic pressure would be sufficient to push the silicone arches down onto the substrates, blocking the channels. Thus, by connecting pneumatic- actuation channels to the two pneumatic sources in spatial and temporal alternation, waves of opening and closing, equivalent to peristalsis, could be made to move along the pump channels. A pump according to this concept could be manufactured inexpensively. Pneumatic sources (compressors and partial vacuum sources) similar those needed for actuation are commercially available; they typically have masses of .100 g and power demands of the order of several W. In a design-optimization effort, it should be possible to reduce masses and power demands below even these low levels and to integrate pneumatic sources along with the proposed pumps into miniature units with overall dimensions of no more than a few centimeters per side.
Comparison of Norethindrone-Containing OCPs to Desogestrel OCPs and Depro-Provera in Women
1999-10-01
it is easy to use or because it induces amenorrhea (12,20-26). To date, however, no study has directly compared continuation rates among these... exercise may help control this weight gain, a willingness to exercise may be impeded by DMPA use as preliminary studies suggest that this method results...not induce cyclic bleeding, as with DMPA (33). Irregular bleeding may also occur with use of hormonal contraception. However, the frequency of
Estimating Fluctuating Pressures From Distorted Measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Leondes, Cornelius T.
1994-01-01
Two algorithms extract estimates of time-dependent input (upstream) pressures from outputs of pressure sensors located at downstream ends of pneumatic tubes. Effect deconvolutions that account for distoring effects of tube upon pressure signal. Distortion of pressure measurements by pneumatic tubes also discussed in "Distortion of Pressure Signals in Pneumatic Tubes," (ARC-12868). Varying input pressure estimated from measured time-varying output pressure by one of two deconvolution algorithms that take account of measurement noise. Algorithms based on minimum-covariance (Kalman filtering) theory.
2011-03-08
pressure gauge on the pneumatic head and indicate the number of inches the water level was lowered in the well to induce the slug test. ERDC/CRREL...a pneumatic slug-test system and its major components. ERDC/CRREL TR-11-6 10 pressure gauge on the pneumatic head, which is graduated in inches...The water level changes induced by the slug test were measured with a 10-psi pressure transducer installed below the water level. An analog-to
Circuit lifespan during continuous renal replacement therapy for combined liver and kidney failure.
Chua, Horng-Ruey; Baldwin, Ian; Bailey, Michael; Subramaniam, Ashwin; Bellomo, Rinaldo
2012-12-01
To evaluate circuit lifespan (CL) and bleeding risk during continuous renal replacement therapy (CRRT), in combined liver and renal failure. Single-center retrospective analysis of adults with acute liver failure or decompensated cirrhosis who received CRRT, without anticoagulation or with heparinization in intensive care unit. Seventy-one patients with 539 CRRT circuits were evaluated. Median overall CL was 9 (6-16) hours. CL was 12 (7-24) hours in 51 patients never anticoagulated for CRRT. In 20 patients who subsequently received heparinization, CL was 7 (5-11) hours without anticoagulation, which did not improve with systemic or regional heparinization (P = .231), despite higher peri-circuit activated partial thromboplastin time (APTT) and heparin dose. Using multivariate linear regression, patients with higher baseline APTT or serum bilirubin, or who were not mechanically ventilated, had longer CL (P < .05). Additionally, peri-circuit thrombocytopenia (P < .0001) or higher international normalized ratio (P < .05) predicted longer CL. Of 71 patients, 33 had significant bleeding events. Using multivariate logistic regression, patients with higher baseline APTT, vasoactive drug use >24 hours, or thrombocytopenia, had more bleeding complications (P < .05). Decreasing platelet counts (especially <50 × 10(9)/mm(3)) had an incremental effect on CL (P < .0001). CRRT CL is short in patients with liver failure despite apparent coagulopathy. Thrombocytopenia predicts longer CL and bleeding complications. Copyright © 2012 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Acetone butanol ethanol (ABE) was produced in an integrated continuous fermentation and product recovery system using a microbial strain Clostridium beijerinckii BA101 for ABE production and fermentation gases (CO2 and H2) for product removal by gas stripping. This represents a continuation of our ...
Freight pipelines: Current status and anticipated future use
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-07-01
This report is issued by the Task Committee on Freight Pipelines, Pipeline Division, ASCE. Freight pipelines of various types (including slurry pipeline, pneumatic pipeline, and capsule pipeline) have been used throughout the world for over a century for transporting solid and sometimes even package products. Recent advancements in pipeline technology, aided by advanced computer control systems and trenchless technologies, have greatly facilitated the transportation of solids by pipelines. Today, in many situations, freight pipelines are not only the most economical and practical means for transporting solids, they are also the most reliable, safest and most environmentally friendly transportation mode. Increasedmore » use of underground pipelines to transport freight is anticipated in the future, especially as the technology continues to improve and surface transportation modes such as highways become more congested. This paper describes the state of the art and expected future uses of various types of freight pipelines. Obstacles hindering the development and use of the most advanced freight pipeline systems, such as the pneumatic capsule pipeline for interstate transport of freight, are discussed.« less
Additively Manufactured Pneumatically Driven Skin Electrodes.
Schubert, Martin; Schmidt, Martin; Wolter, Paul; Malberg, Hagen; Zaunseder, Sebastian; Bock, Karlheinz
2017-12-23
Telemedicine focuses on improving the quality of health care, particularly in out-of-hospital settings. One of the most important applications is the continuous remote monitoring of vital parameters. Long-term monitoring of biopotentials requires skin-electrodes. State-of-the-art electrodes such as Ag/AgCl wet electrodes lead, especially during long-term application, to complications, e.g., skin irritations. This paper presents a low-cost, on-demand electrode approach for future long-term applications. The fully printed module comprises a polymeric substrate with electrodes on a flexible membrane, which establishes skin contact only for short time in case of measurement. The membranes that produce airtight seals for pressure chambers can be pneumatically dilated and pressed onto the skin to ensure good contact, and subsequently retracted. The dilatation depends on the pressure and membrane thickness, which has been tested up to 150 kPa. The electrodes were fabricated in screen and inkjet printing technology, and compared during exemplary electrodermal activity measurement (EDA). The results show less amplitude compared to conventional EDA electrodes but similar behavior. Because of the manufacturing process the module enables high individuality for future applications.
Shibata, Yoshiyuki; Imai, Shingo; Nobutomo, Tatsuya; Miyoshi, Tasuku; Yamamoto, Shin-Ichiroh
2010-01-01
The purpose of this study is to develop a body weight support gait training system for stroke and spinal cord injury. This system consists of a powered orthosis, treadmill and equipment of body weight support. Attachment of the powered orthosis is able to fit subject who has difference of body size. This powered orthosis is driven by pneumatic McKibben actuator. Actuators are arranged as pair of antagonistic bi-articular muscle model and two pairs of antagonistic mono-articular muscle model like human musculoskeletal system. Part of the equipment of body weight support suspend subject by wire harness, and body weight of subject is supported continuously by counter weight. The powered orthosis is attached equipment of body weight support by parallel linkage, and movement of the powered orthosis is limited at sagittal plane. Weight of the powered orthosis is compensated by parallel linkage with gas-spring. In this study, we developed system that has orthosis powered by pneumatic McKibben actuators and equipment of body weight support. We report detail of our developed body weight support gait training system.
Puigmartí-Luis, Josep; Rubio-Martínez, Marta; Imaz, Inhar; Cvetković, Benjamin Z; Abad, Llibertat; Pérez Del Pino, Angel; Maspoch, Daniel; Amabilino, David B
2014-01-28
A spatially controlled synthesis of nanowire bundles of the functional crystalline coordination polymer (CP) Ag(I)TCNQ (tetracyanoquinodimethane) from previously fabricated and trapped monovalent silver CP (Ag(I)Cys (cysteine)) using a room-temperature microfluidic-assisted templated growth method is demonstrated. The incorporation of microengineered pneumatic clamps in a two-layer polydimethylsiloxane-based (PDMS) microfluidic platform was used. Apart from guiding the formation of the Ag(I)Cys coordination polymer, this microfluidic approach enables a local trapping of the in situ synthesized structures with a simple pneumatic clamp actuation. This method not only enables continuous and multiple chemical events to be conducted upon the trapped structures, but the excellent fluid handling ensures a precise chemical activation of the amino acid-supported framework in a position controlled by interface and clamp location that leads to a site-specific growth of Ag(I)TCNQ nanowire bundles. The synthesis is conducted stepwise starting with Ag(I)Cys CPs, going through silver metal, and back to a functional CP (Ag(I)TCNQ); that is, a novel microfluidic controlled ligand exchange (CP → NP → CP) is presented. Additionally, the pneumatic clamps can be employed further to integrate the conductive Ag(I)TCNQ nanowire bundles onto electrode arrays located on a surface, hence facilitating the construction of the final functional interfaced systems from solution specifically with no need for postassembly manipulation. This localized self-supported growth of functional matter from an amino acid-based CP shows how sequential localized chemistry in a fluid cell can be used to integrate molecular systems onto device platforms using a chip incorporating microengineered pneumatic tools. The control of clamp pressure and in parallel the variation of relative flow rates of source solutions permit deposition of materials at different locations on a chip that could be useful for device array preparation. The in situ reaction and washing procedures make this approach a powerful one for the fabrication of multicomponent complex nanomaterials using a soft bottom-up approach.
Rácz, Istvan; Szalai, Milan; Dancs, Nora; Kárász, Tibor; Szabó, Andrea; Csöndes, Mihaly; Horváth, Zoltan
2012-01-01
The aim of this study was to investigate the effect of preemptive pantoprazole infusion on early endoscopic findings in patients with acute ulcer bleeding. Records of 333 patients admitted with acute ulcer bleeding were analyzed. Ulcer bleeders were given either 80 mg bolus of pantoprazole followed by continuous infusion of 8 mg per hour or saline infusion until endoscopy. In 93 patients saline infusion whereas in 240 patients bolus plus infusion of pantoprazole was administrated with mean (±SD) durations of 5.45 ± 12.9 hours and 6.9 ± 13.2 hours, respectively (P = 0.29). Actively bleeding ulcers were detected in 46/240 (19.2%) of cases in the pantoprazole group as compared with 23/93 (24.7%) in the saline infusion group (P = 0.26). Different durations of pantoprazole infusion (0–4 hours, >4 hours, and >6 hours) had no significant effect on endoscopic and clinical outcome parameters in duodenal ulcer bleeders. Gastric ulcer bleeders on pantoprazole infusion longer than 4 and 6 hours before endoscopy had actively bleeding ulcers in 4.3% and 5% compared to the 19.5% active bleeding rate in the saline group (P = 0.02 and P = 0.04). Preemptive infusion of high-dose pantoprazole longer than 4 hours before endoscopy decreased the ratio of active bleeding only in gastric but not in duodenal ulcer patients. PMID:23125849
Evaluation and management of abnormal uterine bleeding in premenopausal women.
Sweet, Mary Gayle; Schmidt-Dalton, Tarin A; Weiss, Patrice M; Madsen, Keith P
2012-01-01
Up to 14 percent of women experience irregular or excessively heavy menstrual bleeding. This abnormal uterine bleeding generally can be divided into anovulatory and ovulatory patterns. Chronic anovulation can lead to irregular bleeding, prolonged unopposed estrogen stimulation of the endometrium, and increased risk of endometrial cancer. Causes include polycystic ovary syndrome, uncontrolled diabetes mellitus, thyroid dysfunction, hyperprolactinemia, and use of antipsychotics or antiepileptics. Women 35 years or older with recurrent anovulation, women younger than 35 years with risk factors for endometrial cancer, and women with excessive bleeding unresponsive to medical therapy should undergo endometrial biopsy. Treatment with combination oral contraceptives or progestins may regulate menstrual cycles. Histologic findings of hyperplasia without atypia may be treated with cyclic or continuous progestin. Women who have hyperplasia with atypia or adenocarcinoma should be referred to a gynecologist or gynecologic oncologist, respectively. Ovulatory abnormal uterine bleeding, or menorrhagia, may be caused by thyroid dysfunction, coagulation defects (most commonly von Willebrand disease), endometrial polyps, and submucosal fibroids. Transvaginal ultrasonography or saline infusion sonohysterography may be used to evaluate menorrhagia. The levonorgestrel-releasing intrauterine system is an effective treatment for menorrhagia. Oral progesterone for 21 days per month and nonsteroidal anti-inflammatory drugs are also effective. Tranexamic acid is approved by the U.S. Food and Drug Administration for the treatment of ovulatory bleeding, but is expensive. When clear structural causes are identified or medical management is ineffective, polypectomy, fibroidectomy, uterine artery embolization, and endometrial ablation may be considered. Hysterectomy is the most definitive treatment.
Chu, Edward W; Chernoguz, Artur; Divino, Celia M
2016-06-01
The perioperative safety profile of clopidogrel, a potent antiplatelet agent used in the management of cardiovascular disease, is unknown, and there are no evidence-based guidelines recommending for either its interruption or continuation at this time. The aim of this study was to determine whether patients who are maintained on clopidogrel before general surgical procedures are at increased risk of perioperative bleeding complications. Patients receiving clopidogrel at the time of elective general surgery were randomized to either discontinue clopidogrel 1 week before surgery (group A) or continue clopidogrel into surgery (group B). All other antiplatelet and anticoagulant agents were discontinued before surgery. The primary end points were perioperative bleeding requiring intraoperative or postoperative transfusion of blood or blood components and bleeding-related readmission, reoperation, or mortality within 90 days of surgery. The secondary end points were perioperative myocardial infarction or cerebrovascular accidents within 90 days of surgery. Thirty-nine patients were enrolled and underwent 43 general surgical operations. Twenty-one procedures were randomized to group A and 22 to group B. The most commonly performed individual procedures were open inguinal hernia repair (23%), laparoscopic cholecystectomy (21%), open ventral hernia repair (15%), laparoscopic ventral hernia repair (11%), and laparoscopic inguinal hernia repair (9%). No perioperative mortalities, bleeding events requiring blood transfusion, or reoperations occurred. One readmission for intra-abdominal hematoma requiring percutaneous drainage occurred in each group (group A: 4.8% vs group B: 4.5%; P = 1.0). No myocardial infarctions or cerebrovascular accidents were observed or reported. The outcomes from this prospective study suggest that, patients undergoing commonly performed elective general surgical procedures can be safely maintained on clopidogrel without increased perioperative bleeding risk. Copyright © 2016 Elsevier Inc. All rights reserved.
Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber
NASA Astrophysics Data System (ADS)
Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan
2013-12-01
This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.
Powered glove with electro-pneumatic actuation unit for the disabled
NASA Astrophysics Data System (ADS)
Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu
2007-12-01
Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.
Manzone, Marco; Balsari, Paolo; Marucco, Paolo; Tamagnone, Mario
2017-03-01
All maize drills produce a fine dust due to the seed coating abrasions that occur inside the seeding element. The air stream generated by the fan of pneumatic drills - necessary to create a depression in the sowing element of the machine and to guarantee correct seed deposition - can blow away the solid particles detached from the seeds. In order to reduce this phenomenon, a coated maize seeds company (Syngenta®) has set up an ad hoc dual-pipe deflector kit that easily fits different pneumatic drills (also old drills). In this study, the efficiency of this kit and the influence of different drill types on the kit's performance in reducing environmental pollution were evaluated using three different pneumatic seed drill models. The research showed that a dual-pipe deflector installed on a drill in standard configuration did not change the seeder performance, and by using this kit on pneumatic drills, irrespective of their design, it is possible to reduce by up to 69% the amount of dust drift in comparison with the conventional machine set-up. The dual-pipe deflector, under the conditions employed in the present experiments, showed good performance with all types of maize pneumatic drill used. Irrespective of the seeder model on which it is mounted, it is able to obtain similar results, indicating its high operational versatility. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Integration of Pneumatic Technology in Powered Mobility Devices
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G.; Schneider, Urs
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs. PMID:29339888
Integration of Pneumatic Technology in Powered Mobility Devices.
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.
Soderdahl, D W; Henderson, S R; Hansberry, K L
1997-05-01
Intermittent pneumatic compression of the calf and/or thigh effectively decreases the incidence of deep venous thrombosis and other thrombotic sequelae but clinical data comparing these modalities are currently lacking. A total of 90 patients undergoing major urological surgery was randomly assigned to receive calf length or thigh length pneumatic compression for antithrombotic prophylaxis. Duplex ultrasound of the lower extremities was performed preoperatively and twice postoperatively to evaluate for deep venous thrombosis. Health care providers in the operating room, recovery room and ward were asked to compare the compression systems, and a cost analysis was performed. A total of 47 patients wore the thigh length sequential pneumatic sleeves and 43 wore calf length uniform compression systems. A pulmonary embolus without evidence of deep venous thrombosis was detected in 1 patient (2%) using the thigh length system. A thrombus was detected in the common femoral vein by duplex ultrasonography in 1 patient (2%) with the calf length system. Nursing personnel found the calf length sleeves easier to apply and more comfortable by patient account but they were satisfied with both systems. There was a significant cost savings with the calf length pneumatic compression system. Calf and thigh length pneumatic compression systems similarly decrease the risk of deep venous thrombosis in patients undergoing urological surgery. The calf length system has the added advantage of being less expensive and easier to use.
Mettler, Liselotte; Schollmeyer, Thoralf; Tinelli, Andrea; Malvasi, Antonio; Alkatout, Ibrahim
2012-01-01
A critical analysis of the surgical treatment of fibroids compares all available techniques of myomectomy. Different statistical analyses reveal the advantages of the laparoscopic and hysteroscopic approach. Complications can arise from the location of the fibroids. They range from intermittent bleedings to continuous bleedings over several weeks, from single pain episodes to severe pain, from dysuria and constipation to chronic bladder and bowel spasms. Very seldom does peritonitis occur. Infertility may result from continuous metro and menorrhagia. The difficulty of the laparoscopic and hysteroscopic myomectomy lies in achieving satisfactory haemostasis using the appropriate sutures. The hysteroscopic myomectomy requires an operative hysteroscope and a well-experienced gynaecologic surgeon. PMID:22619681
An automatic pellet dispenser for precise control of feeding topography in granivorous birds
Berkhoudt, H.; Van Der Reijden, D.; Heijmans, M.
1987-01-01
Design and construction of an automatic pellet dispenser for granivorous birds are described. The dispenser permits rapid pneumatic delivery of pellets (five pellets per second maximum) to one controlled position and does not interfere with simultaneous electrophysiological recording. In addition, the device continuously indicates presence or absence of a pellet in the delivery position. This automatic dispenser proved very effective in our studies of stereotyped topographies of feeding in granivorous birds, such as pigeons and chickens. PMID:16812503
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baucom, R.M.; Marchello, J.M.
Thermoplastic prepregs of LARC-TPI have been produced in a fluidized bed unit on spread continuous fiber tows. The powders are melted on the fibers by radiant heating to adhere the polymer to the fiber. This process produces tow prepreg uniformly without imposing severe stress on the fibers or requiring long high temperature residence times for the polymer. Unit design theory and operating correlations have been developed to provide the basis for scale up to commercial operation. Special features of the operation are the pneumatic tow spreader, fluidized bed and resin feed systems.
A Pneumatic Tactile Sensor for Co-Operative Robots
He, Rui; Yu, Jianjun; Zuo, Guoyu
2017-01-01
Tactile sensors of comprehensive functions are urgently needed for the advanced robot to co-exist and co-operate with human beings. Pneumatic tactile sensors based on air bladder possess some noticeable advantages for human-robot interaction application. In this paper, we construct a pneumatic tactile sensor and apply it on the fingertip of robot hand to realize the sensing of force, vibration and slippage via the change of the pressure of the air bladder, and we utilize the sensor to perceive the object’s features such as softness and roughness. The pneumatic tactile sensor has good linearity, repeatability and low hysteresis and both its size and sensing range can be customized by using different material as well as different thicknesses of the air bladder. It is also simple and cheap to fabricate. Therefore, the pneumatic tactile sensor is suitable for the application of co-operative robots and can be widely utilized to improve the performance of service robots. We can apply it to the fingertip of the robot to endow the robotic hand with the ability to co-operate with humans and handle the fragile objects because of the inherent compliance of the air bladder. PMID:29125565
Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.
Mooney, Luke M; Lai, Cara H; Rouse, Elliott J
2014-01-01
By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.
Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System
NASA Technical Reports Server (NTRS)
Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.
1998-01-01
In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored
Field demonstration of two pneumatic backfilling technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyni, R.C.; Burnett, M.; Philbin, D.
1995-12-31
This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 tomore » 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.« less
Alfotih, Gobran Taha Ahmed; Li, FangCheng; Xu, XinKe; Zhang, ShangYi
2014-01-01
The mortality of re-bleeding following aneurysmal subarachnoid hemorrhage is high, and surviving patients often have poor clinical condition and worse outcome than patients with a single bleed. In this study, we performed an updated systematic review and meta-analysis to determine the most common risk factors for re-bleeding in this patient population, with the goal of providing neurologists, neurosurgeons, neuro-interventionalists with a simple and fast method to evaluate the re-bleeding risk for aneurysmal subarachnoid hemorrhage. We conducted a thorough meta-analysis of the risk factors associated with re-bleeding or re-rupture of intracranial aneurysms in cases published between 2000 and 2013. Pooled mean difference was calculated for the continuous variables (age), and pooled odds ratio (OR) was calculated for categorical factors. If heterogeneity was significant (p<0.05), a random effect model was applied; otherwise, a fixed model was used. Testing for pooled effects and statistical significance for each potential risk factor were analyzed using Review Manager software. Our literature search identified 174 articles. Of these, only seven retrospective studies met the inclusion criteria. These seven studies consisted of 2470 patients, 283 of which had aneurysmal re-bleeding, resulting in a weighted average rate of re-bleeding of 11.3% with 95% confidence interval [CI]: 10.1-12.6. In this population, sex (OR 1.46; 95% CI: 1.11-1.92), high systolic blood pressure [SBP] (OR 2.52; 95% CI: 1.40-4.53), aneurysm size (OR 3.00; 95% CI: 2.06-4.37), clinical condition (Hunt & Hess) (OR 4.94; 95% CI: 2.29,10.68), and Fisher grade (OR 2.29; 95% CI: 1.45, 3.61) were statistically significant risk factors for re-bleeding. Sex, high SBP, high Fisher grade, aneurysm size larger than 10mm, and poor clinical condition were independent risk factors for aneurysmal re-bleeding. The importance of early aneurysm intervention and careful consideration of patient risk factors should be emphasized to eliminate the risk of re-bleeding and poor outcome. Copyright © 2014 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
New protocol of clomiphene citrate treatment in women with hypothalamic amenorrhea.
Borges, Lavinia Estrela; Morgante, Giuseppe; Musacchio, Maria Concetta; Petraglia, Felice; De Leo, Vincenzo
2007-06-01
To determine if a new protocol of administration of clomiphene citrate (CC) is effective in menstrual cycle recovery in women with hypothalamic secondary amenorrhea. This was an open-label study. Patients comprised a group of eight women with secondary amenorrhea. Interventions. An oral preparation containing CC (50 mg/day) was administered for 5 days followed by a double dose (100 mg/day) for another 5 days, initiated on day 3 after estrogen/progestogen-induced withdrawal bleeding. If ovulation and vaginal bleeding occurred, treatment continued in the two next months with 100 mg/day from day 3 to day 7 day of the cycle. Cycle control was evaluated at each visit, when patients recorded bleeding patterns and tablet intake. Data on the intensity and duration of bleeding were collected. Six patients responded to the first cycle of CC administration, resuming normal menstrual cycles. The other two patients failed to menstruate after the first 10 days of treatment with CC and repeated the same protocol. After the second administration, these two women also had normal menstrual bleeding. The present data show that this new protocol of CC treatment may be useful to restore normal menstrual cycles in young women with hypothalamic amenorrhea.
Preoperative Detailed Coagulation Tests Are Required in Patients With Noonan Syndrome.
Morice, Anne; Harroche, Annie; Cairet, Pascale; Khonsari, Roman H
2017-12-29
Patients with Noonan syndrome often require surgery at young ages. They are at high risk of perioperative bleeding from coagulation defects that might not have been detected by routine screening. These risks are rarely described in the oral and maxillofacial surgery (OMS) literature. The aim of this study was to evaluate the perioperative bleeding risks associated with Noonan syndrome and to propose preoperative guidelines. This report describes a retrospective case series of patients with Noonan syndrome who underwent OMS procedures during a continuous observational period (2013 through 2016) in the authors' center. Clinical data, blood screening test results, and perioperative bleeding were analyzed. Five patients (age, 4 to 20 yr) with Noonan syndrome who underwent OMS procedures were included in this study. One patient presented a spontaneous bleeding tendency (epistaxis requiring cauterization). Blood screening showed clotting defects in 3 patients. One patient presented abnormal perioperative bleeding owing to a mild defect in factor XI. Patients with Noonan syndrome must be referred to a hematologist for specific preoperative investigations and for adapted perioperative management. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Ishii, Kenichi; Adachi, Tatsuo; Hara, Takashi; Hamamoto, Hiroshi; Sekimizu, Kazuhisa
2014-03-01
Injection of culture supernatant of Serratia marcescens, a Gram-negative bacterium pathogenic to a wide range of host animals including insects and mammals, into the hemolymph of silkworm (Bombyx mori) larvae led to continuous flow of the hemolymph (blood of insects) from the injection site. The amount of hemolymph lost within 60 min reached 15-20% of the total larval weight. Using a bioassay with live silkworms, we purified Serralysin, a metalloprotease that requires divalent cations for its activity, as the factor responsible for the promotion of hemolymph bleeding from the culture supernatant of S. marcescens. Recombinant protein also induced hemolymph bleeding in silkworms. Moreover, the culture supernatant of an S. marcescens disruption mutant of the ser gene showed attenuated ability to promote hemolymph bleeding. In addition, this bleeding-promoting activity of the S. marcescens culture supernatant was attenuated by disruption of the wecA gene, which is involved in the biosynthesis of the lipopolysaccharide O-antigen. These findings suggest that Serralysin metalloprotease contributes to the pathogenesis of S. marcescens by inhibiting wound healing, which leads to a massive loss of hemolymph from silkworm larvae. Copyright © 2014 Elsevier Inc. All rights reserved.
Anttila, Leena; Neunteufel, Walter; Petraglia, Felice; Marr, Joachim; Kunz, Michael
2011-01-01
The degree of cycle control achieved with a hormonal contraceptive method is an important determinant of its acceptance and continuation. This study set out to compare the cycle control and bleeding profile of drospirenone (DRSP) 3 mg/ethinylestradiol (EE) 20 μg in a 24-active pill/4-inert pill (24/4) regimen (YAZ®) with those of desogestrel (DSG) 150 μg/EE 20 μg in a 21/7 regimen (Mercilon®), an established European combined oral contraceptive (COC). Bleeding data from women aged 17-36 years who received either DRSP 3 mg/EE 20 μg in a 24/4 regimen (n = 1285) or DSG 150 μg/EE 20 μg in a 21/7 regimen (n = 471) during four clinical studies were pooled and analysed over seven treatment cycles. The maximum intensity of scheduled withdrawal bleeding was 'normal bleeding' for >50% of subjects in cycles 1-6 in both treatment groups. Moreover, the incidence of unscheduled intracyclic bleeding during cycles 2-7 was comparable between treatment types (10.2-14.9% in women treated with DRSP 3 mg/EE 20 μg 24/4 vs 8.6-13.8% in women treated with DSG 150 μg/EE 20 μg 21/7). Overall, similar bleeding patterns were observed with both treatments. DRSP 3 mg/EE 20 μg 24/4 is associated with a bleeding profile and cycle control that is comparable to that of an established, low-dose COC formulation.
Wang, Liangcheng; Horiuchi, Isao; Mikami, Yukiko; Takagi, Kenjiro; Okochi, Tomohisa; Hamamoto, Kohei; Chiba, Emiko; Matsuura, Katsuhiko
2015-04-01
Uterine artery embolization (UAE) is a standard method for treating postpartum hemorrhage (PPH), although uterine artery vasospasm during UAE may lead to failure of hemostasis. Here, we report our experience with a case of PPH in which the bleeding was successfully controlled by intra-arterial administration of nitroglycerin during the second UAE. A 30-year-old woman experienced PPH following a successful cesarean section, and a UAE was performed. However, 6 hours later, vaginal bleeding restarted; the reason for unsuccessful embolization during the first UAE was vasoconstriction due to hypovolemic shock. We performed a second UAE, but uterine bleeding continued. After intra-arterial administration of nitroglycerin, hemostasis was confirmed, and there was no reperfusion of the uterine artery. After these two UAE procedures, no recurrence of bleeding was observed. Thus, use of intra-arterial nitroglycerin was effective for controlling uterine artery vasospasm during UAE. However, larger studies are required to confirm these findings. Copyright © 2015. Published by Elsevier B.V.
Rossaint, Rolf; Bouillon, Bertil; Cerny, Vladimir; Coats, Timothy J; Duranteau, Jacques; Fernández-Mondéjar, Enrique; Filipescu, Daniela; Hunt, Beverley J; Komadina, Radko; Nardi, Giuseppe; Neugebauer, Edmund A M; Ozier, Yves; Riddez, Louis; Schultz, Arthur; Vincent, Jean-Louis; Spahn, Donat R
2016-04-12
Severe trauma continues to represent a global public health issue and mortality and morbidity in trauma patients remains substantial. A number of initiatives have aimed to provide guidance on the management of trauma patients. This document focuses on the management of major bleeding and coagulopathy following trauma and encourages adaptation of the guiding principles to each local situation and implementation within each institution. The pan-European, multidisciplinary Task Force for Advanced Bleeding Care in Trauma was founded in 2004 and included representatives of six relevant European professional societies. The group used a structured, evidence-based consensus approach to address scientific queries that served as the basis for each recommendation and supporting rationale. Expert opinion and current clinical practice were also considered, particularly in areas in which randomised clinical trials have not or cannot be performed. Existing recommendations were reconsidered and revised based on new scientific evidence and observed shifts in clinical practice; new recommendations were formulated to reflect current clinical concerns and areas in which new research data have been generated. This guideline represents the fourth edition of a document first published in 2007 and updated in 2010 and 2013. The guideline now recommends that patients be transferred directly to an appropriate trauma treatment centre and encourages use of a restricted volume replacement strategy during initial resuscitation. Best-practice use of blood products during further resuscitation continues to evolve and should be guided by a goal-directed strategy. The identification and management of patients pre-treated with anticoagulant agents continues to pose a real challenge, despite accumulating experience and awareness. The present guideline should be viewed as an educational aid to improve and standardise the care of the bleeding trauma patients across Europe and beyond. This document may also serve as a basis for local implementation. Furthermore, local quality and safety management systems need to be established to specifically assess key measures of bleeding control and outcome. A multidisciplinary approach and adherence to evidence-based guidance are key to improving patient outcomes. The implementation of locally adapted treatment algorithms should strive to achieve measureable improvements in patient outcome.
Inflatable device for installing strain gage bridges
NASA Technical Reports Server (NTRS)
Cook, C. E.; Smith, G. E.; Monaghan, R. C. (Inventor)
1983-01-01
Methods and devices for installing in a tubular shaft multiple strain gages are disclosed with focus on a method and a device for pneumatically forcing strain gages into seated engagement with the internal surfaces of a tubular shaft in an installation of multiple strain gages in a tubular shaft. The strain gages or other electron devices are seated in a template-like component which is wrapped about a pneumatically expansible body. The component is inserted into a shaft and the body is pneumatically expanded after a suitable adhesive was applied to the surfaces.
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the top level of the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
14 CFR Appendix A to Part 33 - Instructions for Continued Airworthiness
Code of Federal Regulations, 2012 CFR
2012-01-01
... features and data to the extent necessary for maintenance or preventive maintenance. (2) A detailed... limits, maximum continuous power or thrust, bleed air, and power extraction required for a relevant... Airworthiness consist of multiple documents, the section required under this paragraph must be included in the...
14 CFR Appendix A to Part 33 - Instructions for Continued Airworthiness
Code of Federal Regulations, 2011 CFR
2011-01-01
... features and data to the extent necessary for maintenance or preventive maintenance. (2) A detailed... limits, maximum continuous power or thrust, bleed air, and power extraction required for a relevant... Airworthiness consist of multiple documents, the section required under this paragraph must be included in the...
González-López, Rogelio; García-Cano, Eugenio; Espinosa-González, Omar; Cruz-Salgado, Ángel; Montiel-Jarquin, Álvaro-José; Hernández-Zamora, Valeria
2015-01-01
Even in expert hands, there can be serious complications when performing an endoscopic retrograde cholangiopancreatography. The most frequent complications are pancreatitis, cholangitis, bleeding, perforation, and acute cholecystitis. The hepatic subcapsular haematoma is a rare complication, with few cases described worldwide. A case is presented of an extremely rare complication of endoscopic retrograde cholangiopancreatography, which required surgical treatment for its resolution without success. This is second case of mortality reported in the literature. Female patient of 30 years old, with indication for endoscopic retrograde cholangiopancreatography due to benign strictures. A hydro-pneumatic dilation and stent placement of 2 gauge 10 fr was performed. She presented abdominal pain after the procedure and significant decline in haemoglobin with no evidence of haemodynamic instability so an abdominal tomography scan was performed, showing no evidence of liver injury. The patient was haemodynamic unstable within 72 h. A laparotomy was required for damage control, with fatal outcome in the intensive care unit due to multiple organ failure. Subcapsular hepatic haematoma after endoscopic retrograde cholangiopancreatography is a rare complication, with few cases reported in the literature. Treatment described in the literature is conservative, resulting in a satisfactory resolution. Copyright © 2015. Published by Masson Doyma México S.A.
Treatment of ureteric calculi--use of Holmium: YAG laser lithotripsy versus pneumatic lithoclast.
Tipu, Salman Ahmed; Malik, Hammad Afzal; Mohhayuddin, Nazim; Sultan, Gauhar; Hussain, Manzoor; Hashmi, Altaf; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hasan
2007-09-01
To compare the efficacy of Holmium: YAG laser and pneumatic lithoclast in treating ureteric calculi. The study included total of 100 patients divided into two equal groups of laser lithotripsy (LL) and pneumatic lithoclast (PL). Study was conducted between September 2006 and February 2007. Inclusion criteria were patients with a ureteric stone of size 1-2 cm and negative urine culture. An x-ray KUB was mandatory. IVU and CT pyelogram were also done when required. Procedures were done under general anaesthesia after a single dose of pre-operative antibiotic. A 7.5 Fr semi rigid ureteroscope was used for ureteroscopy in all cases. Holmium: YAG laser with 365 microm wide probe was employed in laser group and frequency was set between 5 and 10 Hz at a power of 10 to 15 W. Swiss lithoclast with single or multiple fire technique was used accordingly in PL group. Postoperatively patients underwent radiography and helical CT as required at 4th week of follow up to asses stone clearance. The mean patient age in LL and PL group was 38 +/- 10 and 40 +/- 10 years respectively. The male to female ratio and stone size were similar between the groups. Stone migration up in pelvicalyceal system occurred in two patients of LL group while in eight patients of PL group. JJ Stent was placed in 5(10%) patients in laser group where as 13 (26%) patients required it in pneumatic lithoclast group. Stone free rate at 4 weeks was 92% in laser group as compared to 82% in pneumatic lithoclast group. Hospital stay was more than 24 hours in 2 patients of laser group as compared to 5 patients of pneumatic lithoclast group. Complication rate was 4% in LL group whereas it was 14% in PL group. Holmium: YAG laser lithotripsy is a superior technology compared to pneumatic lithoclast in terms of rate of stone clearance and complications, especially in upper ureteric stones.
Spot-Welding Gun With Adjustable Pneumatic Spring
NASA Technical Reports Server (NTRS)
Burley, Richard K.
1990-01-01
Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.
Raĭzberg, S A; Makarov, I Iu; Lorents, A S
2014-01-01
The objective of the present work was to elucidate the structural characteristics of the 9.0 mm pneumatic rifle and three regular types of the bullets differing in the head shape fired from it. Morphological features of the injuries inflicted by such bullets are described in conjunction with the peculiarities of precipitation of the shot products in their projection as the prerequisites for their objective differentiation. Results: The study allowed to reveal the composition of the gunshot residues and to determine the maximum distance of their distribution. The specific features of experimental damage inflicted by the shots from the 9.0 mm pneumatic rifle to the coarse white calico fabric targets were shown to depend on the shot range. The objective signs of the so-called "short-range" shot from the 9.0 mm pneumatic rifle were described for the first time.
Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator
NASA Technical Reports Server (NTRS)
Lin, F. N.; Moore, W. I.; Lundy, F. E.
1981-01-01
Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake
2005-01-01
We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019
Influence of Isoinertial-Pneumatic Mixed Resistances on Force-Velocity Relationship.
Avrillon, Simon; Jidovtseff, Boris; Hug, François; Guilhem, Gaël
2017-03-01
Muscle strengthening is commonly based on the use of isoinertial loading, whereas variable resistances such as pneumatic loading may be implemented to optimize training stimulus. The purpose of the current study was to determine the effect of the ratio between pneumatic and isoinertial resistance on the force-velocity relationship during ballistic movements. A total of 15 participants performed 2 concentric repetitions of ballistic bench-press movements with intention to throw the bar at 30%, 45%, 60%, 75%, and 90% of the maximal concentric repetition with 5 resistance ratios including 100%, 75%, 50%, 25%, or 0% of pneumatic resistance, the additional load being isoinertial. Force-, velocity-, and power-time patterns were assessed and averaged over the concentric phase to determine the force-velocity and power-velocity relationships for each resistance ratio. Each 25% increase in the pneumatic part in the resistance ratio elicited higher movement velocity (+0.11 ± 0.03 m/s from 0% to 80% of the concentric phase) associated with lower force levels (-43.6 ± 15.2 N). Increased isoinertial part in the resistance ratio resulted in higher velocity toward the end of the movement (+0.23 ± 0.01 m/s from 90% to 100%). The findings show that the resistance ratio could be modulated to develop the acceleration phase and force toward the end of the concentric phase (pneumatic-oriented resistance). Inversely, isoinertial-oriented resistance should be used to develop maximal force and maximal power. Resistance modality could, therefore, be considered an innovative variable to modulate the training stimulus according to athletic purposes.
Kearney, Sinéad M.; Kilcawley, Niamh A.; Early, Philip L.; Glynn, Macdara T.; Ducrée, Jens
2016-01-01
Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are ‘low-pass’, i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both ‘hydrostatically’ and ‘hydrodynamically’ triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, ‘dual siphon’ configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction. PMID:27167376
Vaiman, Michael; Klin, Baruch; Rosenfeld, Noa; Abu-Kishk, Ibrahim
2017-01-01
Hemoptysis is an important symptom which causes a major concern, and warrants immediate diagnostic attention. The authors compared a group of patients with pediatric pulmonary hemorrhage with pediatric patients diagnosed with extrapulmonary bleeding focusing on differences in etiology, outcome and differential diagnosis of hemoptysis. We performed the retrospective analysis of medical charts of 134 pediatric patients admitted to the Emergency Department because of pulmonary and extrapulmonary hemorrhage and were diagnosed with suspected hemoptysis or developed hemoptysis (ICD10-CM code R04.2). The cases with pulmonary hemorrhage (Group 1) were compared with cases of extrapulmonary bleeding (Group 2) using the Fisher Exact test or Pearson's χ 2 test for categorical variables. The t-test was used to assess differences between continuous variables of the patients in the two groups. Bloody cough was the presenting symptom in 73.9% of cases. 30 patients had pulmonary hemorrhage (Group 1), while 104 patients had extrapulmonary bleeding (Group 2). The underlying causes of bleeding in Group 2 included epistaxis, inflammatory diseases of nasopharynx and larynx, foreign bodies, gingivitis, and hypertrophy of adenoids. Mortality rate was 10% in Group 1, whereas Group 2 did not have any mortality outcomes during the observation period. Etiologycal factors were significantly different between hemoptysis and extrapulmonary bleeding in children. Our research suggested that pulmonary and extrapulmonary bleeding are two conditions that differ significantly and cannot be unified under one diagnostic code. It is important to differentiate between focal and diffuse cases, and between pulmonary and extrapulmonary hemorrhage due to the diversity of clinical courses and outcomes.
Pneumatic pressure wave generator provides economical, simple testing of pressure transducers
NASA Technical Reports Server (NTRS)
Gaal, A. E.; Weldon, T. P.
1967-01-01
Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-31
... within Site 8 of FTZ 177. The facility is used for the manufacturing, testing, warehousing, packaging...: pneumatic tires, tubes, rolled rim rings, semi-pneumatic tires, herring-bone tires, welding wires and bolts...
Rolling resistance forces in pneumatic tires
DOT National Transportation Integrated Search
1976-01-31
An analysis is presented for the influence of test drum curvature on stress levels and resulting rolling resistance forces in pneumatic tires. The influence of test method on the measurement of rolling loss is also considered, and expressions are der...
Impact of afterload on the assessment of severity of aortic stenosis.
Chang, Sung-A; Kim, Hyung-Kwan; Sohn, Dae-Won
2012-06-01
Aortic stenosis (AS) is increasingly diagnosed in current aging society. Echocardiography is the most important tool in the assessment of AS and its severity. However, load-dependency of Doppler measurement could affect the accuracy of AS severity assessment. We tried to evaluate the impact of afterload on the assessment of AS severity by modification of afterload using pneumatic compression (Pcom). Forty patients diagnosed as moderate or severe AS [effective orifice area of aortic valve (EOA(AV)) by continuity equation of < 1.5 cm(2)] were consecutively enrolled. Patients with severely uncontrolled hypertension, severe left ventricular (LV) dysfunction, and other significant valve disease were excluded. Comprehensive echocardiography was performed at baseline to assess AS severity. Then, pneumatic compression of the lower extremities by 100 mmHg was applied to increase LV afterload. After 3 minutes, echocardiography was repeated to assess AS severity. Mean blood pressure was significantly increased under Pcom (p < 0.001), while heart rate remained unchanged. Peak aortic valve velocity (V(max)) was slightly, but significantly decreased under Pcom (p = 0.03). However, Doppler velocity index and EOA(AV) by continuity equation were not affected by Pcom. AS severity assessment by echocardiography was not dependent on the change of LV afterload imposed by Pcom. AV V(max) was slightly decreased with LV afterload increment, but these changes were too small to alter treatment plan of AS patients. EOA(AV) and Doppler velocity index are more stable parameters for AS severity assessment.
Giersz, Jacek; Bartosiak, Magdalena; Jankowski, Krzysztof
2017-05-15
Continuous photo-induced generation of mercury cold vapor has been successfully coupled with conventional pneumatic nebulization in programmable temperature spray chamber (PCVG-PN-PTSC) allowing fast, sensitive and easy multi-element analysis. The applied technique enabled simultaneous determination of non-volatile forming elements (Fe, Cu, Mn) and volatile Hg, while 15% v/v formic acid is present in the sample. PTSC elevated temperature (40°C) causes partial conversion of sample matrix into vapor form, thus improving plasma robustness. The efficiency of Hg vapor generation and its transport to the plasma is close to 100%. Moreover, spray chamber temperature stabilization improved the precision of the measurements (Hg signal RSD below 0.5%). The achieved limit of detection for Hg (90pgmL -1 ) at 194.23nm with no monochromator purge is better by almost two orders of magnitude than that obtained by conventional PN-ICP-OES. On the other hand, LODs for non-vapor forming elements are comparable to those obtained with pneumatic nebulization. The linear dynamic ranges for all examined elements are at least three orders of magnitude up to 1000ngmL -1 . None mutual interference between examined analytes (Hg, Fe, Cu, Mn) has been observed. The method was validated by the analysis of two CRM materials of different matrix composition (waste water ERM CA713 and estuarine sediment ERM CC580) giving satisfactory results. As low as 2 ppb of Hg can he directly determined in waste water. The proposed procedure uses mild reagents and allows for fast multi-element analysis, and matches green chemistry requirements. Copyright © 2017 Elsevier B.V. All rights reserved.
De Leersnyder, F; Vanhoorne, V; Bekaert, H; Vercruysse, J; Ghijs, M; Bostijn, N; Verstraeten, M; Cappuyns, P; Van Assche, I; Vander Heyden, Y; Ziemons, E; Remon, J P; Nopens, I; Vervaet, C; De Beer, T
2018-03-30
Although twin screw granulation has already been widely studied in recent years, only few studies addressed the subsequent continuous drying which is required after wet granulation and still suffers from a lack of detailed understanding. The latter is important for optimisation and control and, hence, a cost-effective practical implementation. Therefore, the aim of the current study is to increase understanding of the drying kinetics and the breakage and attrition phenomena during fluid bed drying after continuous twin screw granulation. Experiments were performed on a continuous manufacturing line consisting of a twin-screw granulator, a six-segmented fluid bed dryer, a mill, a lubricant blender and a tablet press. Granulation parameters were fixed in order to only examine the effect of drying parameters (filling time, drying time, air flow, drying air temperature) on the size distribution and moisture content of granules (both of the entire granulate and of size fractions). The wet granules were transferred either gravimetrically or pneumatically from the granulator exit to the fluid bed dryer. After a certain drying time, the moisture content reached an equilibrium. This drying time was found to depend on the applied airflow, drying air temperature and filling time. The moisture content of the granules decreased with an increasing drying time, airflow and drying temperature. Although smaller granules dried faster, the multimodal particle size distribution of the granules did not compromise uniform drying of the granules when the target moisture content was achieved. Extensive breakage of granules was observed during drying. Especially wet granules were prone to breakage and attrition during pneumatic transport, either in the wet transfer line or in the dry transfer line. Breakage and attrition of granules during transport and drying should be anticipated early on during process and formulation development by performing integrated experiments on the granulator, dryer and mill. Copyright © 2018 Elsevier B.V. All rights reserved.
Active Control of a Pneumatic Isolation System,
A pneumatically isolated test platform has been modified to provide active control to the local gravity vector. A combination of sensors , including... tiltmeters , angular accelerometers, seismometers, and a gyrocompass measure total platform motion between 0 and 100 Hz. Electrical-to-pressure
23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...
23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
Makarov, I Iu; Raĭzberg, S A
2012-01-01
The data available from the forensic medical practice do not allow the comprehensive, objective, and reliable assessment of injuries to the human body and damages to the clothes inflicted by the shots from a 9 millimeter (.357) or higher-caliber pneumatic rifle equipped with the pre-charge pneumatic system. The use of bullets of specific structure and configuration for such weapons accounts for their marked influence on the morphological features and the extent of the resulting wounds. These peculiarities provide a basis for the objective differentiation between their injurious effects.
Assessment of Pneumatic Controller Emission Measurements ...
Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co
Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.
Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J
2017-07-01
The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.
Stulak, John M; Lee, Dustin; Haft, Jonathon W; Romano, Matthew A; Cowger, Jennifer A; Park, Soon J; Aaronson, Keith D; Pagani, Francis D
2014-01-01
Modern left ventricular assist devices (LVAD) require anti-coagulation (AC) with warfarin and anti-platelet therapy to prevent thromboembolic complications in patients. Gastrointestinal bleeding (GI) is a significant adverse event in these patients and treatment typically requires reduction or elimination of AC or anti-platelet therapy. It is not known whether alterations in AC to treat GI bleeding influence subsequent risk of thromboembolic (TE) events during LVAD support. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous-flow LVAD at the University of Michigan Health System and the Mayo Clinic. Median age at implant was 60 years (range 18 to 79 years). Outcomes were analyzed for the association of GI bleeding events and subsequent TE events, defined as stroke, transient ischemic attack, hemolysis or suspected or confirmed pump thrombosis. Median survival was 10 months (maximum 7.2 years, total 439 patient-years). TE events occurring within the first 30 days were not counted. Overall survival and freedom from an outcome event were assessed using the Kaplan-Meier method. Associations between GI bleeding and subsequent TE events and survival impact were analyzed as time-dependent covariates. One hundred ninety-nine GI bleeding episodes occurred in 116 of 389 patients (30%) for an event rate of 0.45 GI bleed/patient-year of support. One hundred thirty-eight TE events occurred in 97 of 389 patients (25%) for an event rate of 0.31 TE event/patient-year of support. Median time from LVAD implant to first GI bleed was 5 months (range 1 to 116 months) and to first TE event was 6 months (range 1 to 29 months). For patients who had a TE event after GI bleed, the median interval was 5 months (range 0.5 to 25 months). TE events were 7.4-fold more likely in patients who had a prior GI bleed (range 4.9- to 11.1-fold) (p < 0.001); however, neither the presence of GI bleeding (0.7 to 1.2) nor a TE event (0.8 to 2.0) portended a lower overall survival. Patients who had GI bleeding were at significantly higher risk for a subsequent TE event. Although the exact cause of this relationship is unknown, it suggests that a reduction in anti-coagulation and anti-platelet management to treat GI bleeds may contribute to this risk. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Real-time imaging of subarachnoid hemorrhage in piglets with electrical impedance tomography.
Dai, Meng; Wang, Liang; Xu, Canhua; Li, Lianfeng; Gao, Guodong; Dong, Xiuzhen
2010-09-01
Subarachnoid hemorrhage (SAH) is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would significantly reduce the rate of disability and mortality, and improve the prognosis of the patients. Although the present medical imaging techniques generally have high sensitivity to identify bleeding, the use of an additional, non-invasive imaging technique capable of continuously monitoring SAH is required to prevent contingent bleeding or re-bleeding. In this study, electrical impedance tomography (EIT) was applied to detect the onset of SAH modeled on eight piglets in real time, with the subsequent process being monitored continuously. The experimental SAH model was introduced by one-time injection of 5 ml fresh autologous arterial blood into the cisterna magna. Results showed that resistivity variations within the brain caused by the added blood could be detected using the EIT method and may be associated not only with the resistivity difference among brain tissues, but also with variations of cerebrospinal fluid dynamics. In conclusion, EIT has unique potential for use in clinical practice to provide invaluable real-time neuroimaging data for SAH after the improvement of electrode design, anisotropic realistic modeling and instrumentation.
Current options and new developments in the treatment of haemophilia.
Wong, Trisha; Recht, Michael
2011-02-12
Haemophilia A and B are X-linked bleeding disorders due to the inherited deficiency of factor VIII or factor IX, respectively. Of the approximately 1 per 5000-10000 male births affected by haemophilia, 80% are deficient in factor VIII and 20% are deficient in factor IX. Haemophilia is characterized by spontaneous and provoked joint, muscle, gastrointestinal and CNS bleeding leading to major morbidity and even mortality if left untreated or under-treated. The evolution of haemophilia management has been marked by tragedy and triumph over recent decades. Clotting factors and replacement strategies continue to evolve for patients without inhibitors. For patients with an inhibitor, factor replacement for acute bleeding episodes and immune tolerance, immune modulation and extracorporeal methods for inhibitor reduction are the cornerstone of care. In addition, adjuvant therapies such as desmopressin, antifibrinolytics and topical agents also contribute to improved outcomes for patients with and without inhibitors. The future direction of haemophilia care is promising with new longer-acting clotting factors and genetic therapies, including gene transfer and premature termination codon suppressors. With these current and future treatment modalities, the morbidity and mortality rates in patients with haemophilia certainly will continue to improve.
Outcome of Isolated Premature Menarche: A Retrospective and Follow-Up Study.
Ejaz, Sehar; Lane, Andrew; Wilson, Thomas
2015-01-01
Isolated premature menarche is isolated or recurrent vaginal bleeding in a female in the absence of appropriate secondary sexual characters. Retrospective chart review of patients with premature menarche, followed by a telephone questionnaire. Charts of patients evaluated in the Pediatric Endocrine Clinic for premature vaginal bleeding from 1982-2013 were reviewed. Of 21 patients identified, 17 could be contacted. Five newly diagnosed patients were recruited during the course of the study. The median age at initial presentation was 7 years. Most patients presented with Tanner I sexual development. Some had more advanced breast staging, which regressed later. All had prepubertal baseline and stimulated gonadotropins. Most of the patients reported a single or few episodes of menses. Two reported continuation of irregular bleeding into adulthood. All reported an adult height within the midparental target height. Premature menarche in the absence of other appropriate secondary sexual characteristics is a benign entity. Most patients have a few isolated episodes of menses that stop spontaneously; some may continue to have periods into adulthood. Unlike true puberty, these patients do not demonstrate advanced skeletal maturation, and the adult height is normal. Fertility appears to be normal. © 2015 S. Karger AG, Basel.
DOT National Transportation Integrated Search
2016-12-01
The following progress report describes the laboratory activities completed for the development of the experimental field program designed to evaluate sediment amendment using the Pneumatic Flow Tube Mixing Apparatus (PFTM) in NY/NJ Harbor. These act...
46 CFR 76.05-1 - Fire detecting systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...
46 CFR 76.05-1 - Fire detecting systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...
... several hours. Your provider may prescribe medicine for pain and nausea if needed to ease your discomfort during this process. ... Risks of medical abortion include: Continued bleeding Diarrhea ... body, making surgery necessary Infection Nausea Pain Vomiting
Oral rivaroxaban for symptomatic venous thromboembolism.
Bauersachs, Rupert; Berkowitz, Scott D; Brenner, Benjamin; Buller, Harry R; Decousus, Hervé; Gallus, Alex S; Lensing, Anthonie W; Misselwitz, Frank; Prins, Martin H; Raskob, Gary E; Segers, Annelise; Verhamme, Peter; Wells, Phil; Agnelli, Giancarlo; Bounameaux, Henri; Cohen, Alexander; Davidson, Bruce L; Piovella, Franco; Schellong, Sebastian
2010-12-23
Rivaroxaban, an oral factor Xa inhibitor, may provide a simple, fixed-dose regimen for treating acute deep-vein thrombosis (DVT) and for continued treatment, without the need for laboratory monitoring. We conducted an open-label, randomized, event-driven, noninferiority study that compared oral rivaroxaban alone (15 mg twice daily for 3 weeks, followed by 20 mg once daily) with subcutaneous enoxaparin followed by a vitamin K antagonist (either warfarin or acenocoumarol) for 3, 6, or 12 months in patients with acute, symptomatic DVT. In parallel, we carried out a double-blind, randomized, event-driven superiority study that compared rivaroxaban alone (20 mg once daily) with placebo for an additional 6 or 12 months in patients who had completed 6 to 12 months of treatment for venous thromboembolism. The primary efficacy outcome for both studies was recurrent venous thromboembolism. The principal safety outcome was major bleeding or clinically relevant nonmajor bleeding in the initial-treatment study and major bleeding in the continued-treatment study. The study of rivaroxaban for acute DVT included 3449 patients: 1731 given rivaroxaban and 1718 given enoxaparin plus a vitamin K antagonist. Rivaroxaban had noninferior efficacy with respect to the primary outcome (36 events [2.1%], vs. 51 events with enoxaparin-vitamin K antagonist [3.0%]; hazard ratio, 0.68; 95% confidence interval [CI], 0.44 to 1.04; P<0.001). The principal safety outcome occurred in 8.1% of the patients in each group. In the continued-treatment study, which included 602 patients in the rivaroxaban group and 594 in the placebo group, rivaroxaban had superior efficacy (8 events [1.3%], vs. 42 with placebo [7.1%]; hazard ratio, 0.18; 95% CI, 0.09 to 0.39; P<0.001). Four patients in the rivaroxaban group had nonfatal major bleeding (0.7%), versus none in the placebo group (P=0.11). Rivaroxaban offers a simple, single-drug approach to the short-term and continued treatment of venous thrombosis that may improve the benefit-to-risk profile of anticoagulation. (Funded by Bayer Schering Pharma and Ortho-McNeil; ClinicalTrials.gov numbers, NCT00440193 and NCT00439725.).
Dabigatran and kidney disease: a bad combination.
Knauf, Felix; Chaknos, C Michael; Berns, Jeffrey S; Perazella, Mark A
2013-09-01
Dabigatran is an oral direct thrombin inhibitor widely used to prevent and treat various thromboembolic complications. An advantage of this agent over other anticoagulants is that routine laboratory monitoring and related dose adjustments are considered unnecessary. A major disadvantage is the absence of a reliable means of reversing its anticoagulant effect. After U.S. Food and Drug Administration approval, recently emerged data suggest a higher bleeding risk with dabigatran, especially in the elderly. Clinicians are thus faced with caring for patients with serious bleeding events without readily available tests to measure drug levels or the anticoagulant effects of dabigatran and without effective antidotes to rapidly reverse the anticoagulant effect. On the basis of dabigatran's pharmacokinetic profile, hemodialysis and continuous renal replacement therapy have been used to remove dabigatran with the hope, still unproven, that this would rapidly reverse the anticoagulant effect and reduce bleeding in patients with normal and those with reduced kidney function. However, the best clinical approach to the patient with serious bleeding is not known, and the risks of placing a hemodialysis catheter in an anticoagulated patient can be substantial. This article reviews this issue, addressing clinical indications, drug pharmacokinetics, clinical and laboratory monitoring tests, and dialytic and nondialytic approaches to reduce bleeding in dabigatran-treated patients.
Jutabha, Rome; Jensen, Dennis M.; Chavalitdhamrong, Disaya
2013-01-01
OBJECTIVES: Our purpose was to compare the efficacy, complications, success rate, recurrence rate at 1 year, and crossovers of rubber band ligation (RBL) with those of bipolar electrocoagulation (BPEC) treatment for chronically bleeding internal hemorrhoids. METHODS: A total of 45 patients of mean age 51.5 years, who had rectal bleeding from grade II or III hemorrhoids and in whom intensive medical therapy failed, were randomized in a prospective study comparing RBL with BPEC. Treatment failure was predefined as continued bleeding, occurrence of a major complication, or failure to reduce the size of all internal hemorrhoidal segments to grade I in ≤ 3 treatments. Patients were followed up for 1 year. RESULTS: With similar patients, rectal bleeding and other symptoms were controlled with significantly fewer treatments of RBL than of BPEC (2.3±0.2 vs. 3.8±0.4, P < 0.05), and RBL had a significantly higher success rate (92% vs. 62%, P< 0.05). RBL had more cases of severe pain during treatment (8% vs. 0%, P> 0.05), but significantly fewer failures and crossovers (8% vs. 38%). Symptomatic recurrence at 1 year was 10% RBL and 15% BPEC. CONCLUSIONS: For patients with chronically bleeding grade II or III internal hemorrhoids that are unresponsive to medical therapy, safety and complication rates of banding and BPEC were similar. The success rate was significantly higher with RBL than with BPEC. Symptom recurrence rates at 1 year were similar. PMID:19513028
Lou, Wenhui; Xia, Ying; Xiang, Peng; Zhang, Liangqing; Yu, Xiangyou; Lim, Sam; Xu, Mo; Zhao, Lina; Rydholm, Hans; Traxler, Barry; Qin, Xinyu
2018-04-20
To assess the efficacy and safety of esomeprazole in preventing upper gastrointestinal (GI) bleeding in critically ill Chinese patients, using cimetidine as an active comparator. A pre-specified non-inferiority limit (5%) was used to compare rates of significant upper GI bleeding in this randomized, double-blind, parallel-group, phase 3 study across 27 intensive care units in China. Secondary endpoints included safety and tolerability measures. Patients required mechanical ventilation and had at least one additional risk factor for stress ulcer bleeding. Patients were randomized to receive either active esomeprazole 40 mg, as a 30-min intravenous (IV) infusion twice daily, and an IV placebo cimetidine infusion or active cimetidine 50 mg/h, as a continuous infusion following an initial bolus of 300 mg, and placebo esomeprazole injections, given up to 14 days. Patients were blinded using this double-dummy technique. Of 274 patients, 2.7% with esomeprazole and 4.6% with cimetidine had significant upper GI bleeding (bright red blood in the gastric tube not clearing after lavage or persistent Gastroccult-positive "coffee grounds" material). Non-inferiority of esomeprazole to cimetidine was demonstrated. The safety profiles of both drugs were similar and as expected in critically ill patients. Esomeprazole is effective in preventing upper GI bleeding in critically ill Chinese patients, as demonstrated by the non-inferiority analysis using cimetidine as an active control. ClinicalTrials.gov identifier NCT02157376.
Liver haemostasis using microbubble-enhanced ultrasound at a low acoustic intensity.
Zhao, Xiaochen; Li, Lu; Zhao, Hongzhi; Li, Tao; Wu, Shengzheng; Zhong, Yu; Zhao, Yang; Liu, Zheng
2012-02-01
To explore the haemostatic effects of microbubble-enhanced ultrasound (MEUS) at a very low acoustic intensity on the bleeding liver of rabbits. Liver incisions made on 20 rabbits were treated with a pulsed therapeutic ultrasound transducer. The transducer was operated at 831 KHz with an acoustic intensity of 0.4 W/cm(2). The treatment was coordinated with intravenous injection of microbubbles. Ultrasound only and sham treatment served as the controls. Visual bleeding score and 10-min bleeding volume were evaluated for haemostatic efficacy. Contrast-enhanced ultrasound (CEUS) was performed to assess the liver perfusion. Nine treated livers were harvested for acute histological examination. Regarding the bleeding incisions made on rabbit livers, the haemorrhage stopped immediately after 2 min of MEUS treatment but bleeding continued in the controls treated by ultrasound or microbubble injection alone. The bleeding scores and the 10-min haemorrhagic volumes dropped significantly in the MEUS group compared with those of the controls (p < 0.01). The mechanism of MEUS haemostasis appears to involve the extensive swelling of hepatocytes and the haemorrhage of the portal area, which formed a joint compression on the regional liver circulation. Low acoustic intensity MEUS might provide a novel method for liver haemostasis. • This animal experiment demonstrates a novel method of controlling hepatic haemorrhage • The treatment uses therapeutic ultrasound during enhancement with intravenous microbubbles • This combined therapy was more effective than ultrasound or intravenous microbubbles alone • More work is required with larger animals before potential human trials.
NASA Technical Reports Server (NTRS)
Baucom, Robert M.; Marchello, Joseph M.
1990-01-01
Thermoplastic prepregs of LARC-TPI have been produced in a fluidized bed unit on spread continuous fiber tows. The powders are melted on the fibers by radiant heating to adhere the polymer to the fiber. This process produces tow prepreg uniformly without imposing severe stress on the fibers or requiring long high temperature residence times for the polymer. Unit design theory and operating correlations have been developed to provide the basis for scale up to commercial operation. Special features of the operation are the pneumatic tow spreader, fluidized bed and resin feed systems.
LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...
LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Compaction of asphaltic concrete pavement with high intensity pneumatic roller : part I.
DOT National Transportation Integrated Search
1963-07-01
The purpose of this investigation was to: : 1) Determine the magnitude of the compactive effort and the umber of passes required in the field to obtain optimum density using a high intensity pneumatic roller. : 2) Effect a correlation between the fie...
A Rare Cause of Headache: Pneumatized Nasal Septum Osteoma.
Erdoğan, Osman; Ismi, Onur; Tezer, Mesut Sabri
2017-11-01
Paranasal sinus osteomas are among the rare causes of headache and they are most commonly seen in the frontal and ethmoid sinuses. In this report, we presented the first case of pneumatized nasal septum osteoma causing headache, successfully treated with endoscopic transnasal approach.
DOT National Transportation Integrated Search
2013-07-01
This study explored possibilities for using existing transportation infrastructure for the cost-effective : installation of pneumatic waste-collection technology in Manhattan. If shown to be economically and : operationally feasible, reducing the num...
The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems
NASA Technical Reports Server (NTRS)
Fischer, J. S.
1977-01-01
The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.
A Model-Based Prognostics Approach Applied to Pneumatic Valves
NASA Technical Reports Server (NTRS)
Daigle, Matthew J.; Goebel, Kai
2011-01-01
Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.
Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve
2018-02-01
Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.
GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING
2013-01-01
The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044
OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles
NASA Technical Reports Server (NTRS)
Wichmann, H.
1974-01-01
Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.
Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve
2018-01-01
Abstract Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally. PMID:29412080
Future Prospects for the Total Artificial Heart.
Sunagawa, Gengo; Horvath, David J; Karimov, Jamshid H; Moazami, Nader; Fukamachi, Kiyotaka
2016-01-01
A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.
Repplinger, Daniel J; Hoffman, Robert S; Nelson, Lewis S; Hines, Elizabeth Q; Howland, MaryAnn; Su, Mark K
2016-09-01
Since intentional overdose with rivaroxaban is expected to lead to significant coagulopathy and bleeding, prophylactic reversal has been suggested. We report a single massive ingestion confirmed by a blood concentration that was managed with expectant therapy alone. A 71-year-old man with atrial fibrillation, aortic valve replacement, and congestive heart failure presented to the emergency department after an intentional ingestion of 97 (1940 mg total) rivaroxaban tablets in a suicide attempt. Initial laboratories revealed: PT, 60.2 s; INR 7.2; aPTT, 55.7 s; BUN 28 mg/dL; and creatinine 1.2 mg/dL. A whole-blood rivaroxaban concentration obtained on hospital-day three was 160 ng/mL. The patient was admitted for continued observation and the coagulation markers trended downward with no major bleeding events. No reversal agents or blood products were given during his hospitalization. In the setting of a single, acute rivaroxaban overdose, with normal renal function, and no active bleeding, conservative therapy alone may be sufficient.
Bianchi, Bernardo; Varazzani, Anea; Ferri, Anea; Menozzi, Roberto; Sesenna, Enrico
2016-03-01
Removal of third molars is a common surgical procedure with low complication rates. Localized alveolar osteitis, infection, bleeding, and paresthesia are the four most common postoperative complications of third molar extraction reported in the literature. Postoperative severe hemorrhages are rare and are usually related to inferior alveolar artery damage. Although most bleeding is usually managed effectively by local compression or packing of the socket, even life-threatening complications may occur. Endovascular embolization has been rarely reported as treatment for such a complication and represents an ideal solution, with a low complication rate and excellent control of bleeding. The authors report a case of potentially life-threatening hemorrhage continuing 4 days after extraction of the mandibular right third molar, resulting in significant anemia (Hb 6.6 g/dL) and treated successfully with endovascular embolization of the inferior alveolar artery. The authors consider it important for general practitioners to know this treatment and how to manage this rare complication in the correct way, saving time if satisfactory hemostasis cannot be reached with common procedures.
Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F
2017-11-01
Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate-loaded machines were effective in improving lower body power and physical function in older adults. The results suggest that power training can be safely and effectively performed by older adults using either pneumatic or plate-loaded machines. Copyright © 2017 Elsevier Inc. All rights reserved.
Klukowska, A; Szczepański, T; Vdovin, V; Knaub, S; Bichler, J; Jansen, M; Dzhunova, I; Liesner, R J
2018-03-26
Nuwiq ® (human-cl rhFVIII, simoctocog alfa) is a 4th generation recombinant human FVIII, without chemical modification or fusion with any other protein, produced in a human cell line. This study (GENA-13) was an extension of the GENA-03 study in which previously treated children aged 2-12 years with severe haemophilia A received Nuwiq ® prophylaxis for ≥6 months. GENA-13 examined long-term tolerability, immunogenicity and efficacy of Nuwiq ® prophylaxis in children. Of 59 patients enrolled in GENA-03, 49 continued Nuwiq ® prophylaxis in GENA-13 for a median (range) of 30.0 (9.5-52.0) months. No patient withdrew due to drug-related adverse events or developed inhibitors. Only 2 of 20 518 infusions were associated with possibly related adverse events (dyspnoea, fever). The estimated annualized bleeding rate (ABR) was 0.67 (95% CI: 0.44, 1.02) for spontaneous and 2.88 (95% CI: 1.86, 4.46) for all bleeds. Younger children (2-5 years) had lower ABRs than children aged 6-12 years. Annualized bleeding rates were reduced in GENA-13 vs GENA-03, especially for spontaneous bleeds in younger children (71% reduction; ABR ratio 0.29 [95% CI: 0.11, 0.74]). Nuwiq ® efficacy was rated as excellent/good in the treatment of 83.0% of 305 evaluated breakthrough bleeds. Surgical prophylaxis with Nuwiq ® was rated as excellent for all 17 assessed procedures. Long-term treatment with Nuwiq ® for the prevention of bleeds in children with severe haemophilia A was well tolerated, effective and reduced spontaneous bleeding by up to 70% compared with GENA-03. © 2018 The Authors. Haemophilia published by John Wiley & Sons Ltd.
Evaluation of a pneumatic Martian soil sampler concept
NASA Technical Reports Server (NTRS)
Schaefer, John L.; Neathery, James K.; Stencel, John M.
1994-01-01
The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.
Tomizawa, Yutaka; Tanaka, Akiko; Kitahara, Hiroto; Sakuraba, Atsushi; Uriel, Nir; Jeevanandam, Valluvan; Ota, Takeyoshi
2018-06-01
Large scale data on preoperative risk stratification for gastrointestinal bleeding (GIB) following continuous-flow left ventricular assist device (CF-LVAD) implantation are scarce. To identify independent predictors for GIB following CF-LVAD implantation. We conducted a retrospective cohort study of consecutive 243 patients who underwent CF-LVAD implantation (HeartMateII) from January 2009 to March 2015 at the University of Chicago Medical Center. GIB was defined as the presence of overt bleeding or occult GIB with ≥ 2 g/dl drop in hemoglobin (Hgb) from recorded baseline values and hemoccult-positive stool. The preoperative and postoperative data were reviewed. Within a median follow-up duration of 408 (IQR 113-954) days, 83 (34%) patients developed GIB after a median of 149 (IQR 27-615) days after implantation of CF-LVAD. There were no significant differences between the groups of GIB and non-GIB with respect to preoperative demographics and comorbidity except for ethnicity. The source of bleeding was identified in 39 (47%) patients and arteriovenous malformation or submucosal streaming vessel was the most frequent cause of bleeding (18/39, 46%). Multivariate-adjusted analysis demonstrated preoperative central venous pressure (CVP) ≥ 18 mmHg (HR 3.56; 95% CI 1.16-10.9; p = 0.026), mean pulmonary artery pressure (mPA) ≥ 36 mmHg (HR 4.14; 95% CI 1.35-12.7; p = 0.013), and the presence of moderate/severe tricuspid valve disease (HR 1.01; 95% CI 1.01-3.86; p = 0.046) were associated with the risk of GIB. In this study, preoperative right-sided cardiac congestion (i.e., increased CVP, mPA and the presence of moderate/severe tricuspid valve disease) was associated with GIB in patients with CF-LVAD.
ERIC Educational Resources Information Center
Engelbrecht, Nancy; And Others
This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…
Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop
USDA-ARS?s Scientific Manuscript database
Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...
Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop
USDA-ARS?s Scientific Manuscript database
Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...
DOT National Transportation Integrated Search
2001-01-16
This report was prepared in order to document the findings of a one year environmental and hydrographic survey program conducted as part of the Air GuardTM Pneumatic Sediment Suspension System installation at IMTT in Bayonne. This system was installe...
This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...
Pneumatic vacuum tube message center, basement room 23, looking southeast ...
Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Braided artificial muscles: modeling and experimental validation
NASA Astrophysics Data System (ADS)
Dragan, Liliana; Cioban, Horia
2009-01-01
The paper presents a few graphical modalities for constructing the double helical braid, which is the basis for the braided artificial pneumatic muscles, by using specialized software applications. This represents the first stage in achieving the method of finite element analysis of this type of linear pneumatic actuator.
Electropneumatic transducer automatically limits motor current
NASA Technical Reports Server (NTRS)
Lovitt, T. F.
1966-01-01
Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.
60. Shock isolator at center, pneumatic control group panel at ...
60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
ERIC Educational Resources Information Center
Foley, Greg
2011-01-01
Continuous feed and bleed ultrafiltration, modeled with the gel polarization model for the limiting flux, is shown to provide a rich source of non-linear algebraic equations that can be readily solved using numerical and graphical techniques familiar to undergraduate students. We present a variety of numerical problems in the design, analysis, and…
An, JaeJin; Niu, Fang; Lang, Daniel T; Jazdzewski, Kristin P; Le, Paul T; Rashid, Nazia; Meissner, Brian; Mendes, Robert; Dills, Diana G; Aranda, Gustavus; Bruno, Amanda
2015-01-01
Background The quality of antithrombotic therapy for patients with nonvalvular atrial fibrillation during routine medical care is often suboptimal. Evidence linking stroke and bleeding risk with antithrombotic treatment is limited. The purpose of this study was to evaluate the associations between antithrombotic treatment episodes and outcomes. Methods and Results A retrospective longitudinal observational cohort study was conducted using patients newly diagnosed with nonvalvular atrial fibrillation with 1 or more stroke risk factors (CHADS2 ≥1) in Kaiser Permanente Southern California between January 1, 2006 and December 31, 2011. A total of 1782 stroke and systemic embolism (SE) and 3528 major bleed events were identified from 23 297 patients during the 60 021 person-years of follow-up. The lowest stroke/SE rates and major bleed rates were observed in warfarin time in therapeutic range (TTR) ≥55% episodes (stroke/SE: 0.87 [0.71 to 1.04]; major bleed: 4.91 [4.53 to 5.28] per 100 person-years), which was similar to the bleed rate in aspirin episodes (4.95 [4.58 to 5.32] per 100 person-years). The warfarin TTR ≥55% episodes were associated with a 77% lower risk of stroke/SE (relative risk=0.23 [0.18 to 0.28]) compared to never on therapy; and the warfarin TTR <55% and on-aspirin episodes were associated with a 20% lower and with a 26% lower risk of stroke/SE compared to never on therapy, respectively. The warfarin TTR <55% episodes were associated with nearly double the risk of a major bleed compared to never on therapy (relative risk=1.93 [1.74 to 2.14]). Conclusions Continuation of antithrombotic therapy as well as maintaining an adequate level of TTR is beneficial to prevent strokes while minimizing bleeding events. PMID:26187996
Lipsky, Andrew H; Farooqui, Mohammed Z H; Tian, Xin; Martyr, Sabrina; Cullinane, Ann M; Nghiem, Khanh; Sun, Clare; Valdez, Janet; Niemann, Carsten U; Herman, Sarah E M; Saba, Nakhle; Soto, Susan; Marti, Gerald; Uzel, Gulbu; Holland, Steve M; Lozier, Jay N; Wiestner, Adrian
2015-12-01
Ibrutinib is associated with bleeding-related adverse events of grade ≤ 2 in severity, and infrequently with grade ≥ 3 events. To investigate the mechanisms of bleeding and identify patients at risk, we prospectively assessed platelet function and coagulation factors in our investigator-initiated trial of single-agent ibrutinib for chronic lymphocytic leukemia. At a median follow-up of 24 months we recorded grade ≤ 2 bleeding-related adverse events in 55% of 85 patients. No grade ≥ 3 events occurred. Median time to event was 49 days. The cumulative incidence of an event plateaued by 6 months, suggesting that the risk of bleeding decreases with continued therapy. At baseline, von Willebrand factor and factor VIII levels were often high and normalized on treatment. Platelet function measured via the platelet function analyzer (PFA-100™) was impaired in 22 patients at baseline and in an additional 19 patients on ibrutinib (often transiently). Collagen and adenosine diphosphate induced platelet aggregation was tested using whole blood aggregometry. Compared to normal controls, response to both agonists was decreased in all patients with chronic lymphocytic leukemia, whether on ibrutinib or not. Compared to untreated chronic lymphocytic leukemia patients, response to collagen showed a mild further decrement on ibrutinib, while response to adenosine diphosphate improved. All parameters associated with a significantly increased risk of bleeding-related events were present at baseline, including prolonged epinephrine closure time (HR 2.74, P=0.012), lower levels of von Willebrand factor activity (HR 2.73, P=0.009) and factor VIII (HR 3.73, P=0.0004). In conclusion, both disease and treatment-related factors influence the risk of bleeding. Patients at greater risk for bleeding of grade ≤ 2 can be identified by clinical laboratory tests and counseled to avoid aspirin, non-steroidal anti-inflammatory drugs and fish oils. ClinicalTrials.gov identifier NCT01500733. Copyright© Ferrata Storti Foundation.
Lipsky, Andrew H.; Farooqui, Mohammed Z.H.; Tian, Xin; Martyr, Sabrina; Cullinane, Ann M.; Nghiem, Khanh; Sun, Clare; Valdez, Janet; Niemann, Carsten U.; Herman, Sarah E. M.; Saba, Nakhle; Soto, Susan; Marti, Gerald; Uzel, Gulbu; Holland, Steve M.; Lozier, Jay N.; Wiestner, Adrian
2015-01-01
Ibrutinib is associated with bleeding-related adverse events of grade ≤2 in severity, and infrequently with grade ≥3 events. To investigate the mechanisms of bleeding and identify patients at risk, we prospectively assessed platelet function and coagulation factors in our investigator-initiated trial of single-agent ibrutinib for chronic lymphocytic leukemia. At a median follow-up of 24 months we recorded grade ≤2 bleeding-related adverse events in 55% of 85 patients. No grade ≥3 events occurred. Median time to event was 49 days. The cumulative incidence of an event plateaued by 6 months, suggesting that the risk of bleeding decreases with continued therapy. At baseline, von Willebrand factor and factor VIII levels were often high and normalized on treatment. Platelet function measured via the platelet function analyzer (PFA-100™) was impaired in 22 patients at baseline and in an additional 19 patients on ibrutinib (often transiently). Collagen and adenosine diphosphate induced platelet aggregation was tested using whole blood aggregometry. Compared to normal controls, response to both agonists was decreased in all patients with chronic lymphocytic leukemia, whether on ibrutinib or not. Compared to untreated chronic lymphocytic leukemia patients, response to collagen showed a mild further decrement on ibrutinib, while response to adenosine diphosphate improved. All parameters associated with a significantly increased risk of bleeding-related events were present at baseline, including prolonged epinephrine closure time (HR 2.74, P=0.012), lower levels of von Willebrand factor activity (HR 2.73, P=0.009) and factor VIII (HR 3.73, P=0.0004). In conclusion, both disease and treatment-related factors influence the risk of bleeding. Patients at greater risk for bleeding of grade ≤2 can be identified by clinical laboratory tests and counseled to avoid aspirin, non-steroidal anti-inflammatory drugs and fish oils. ClinicalTrials.gov identifier NCT01500733 PMID:26430171
Araújo, Ricardo; Mateus, Octávio
2015-01-01
The quadrate of reptiles and most other tetrapods plays an important morphofunctional role by allowing the articulation of the mandible with the cranium. In Theropoda, the morphology of the quadrate is particularly complex and varies importantly among different clades of non-avian theropods, therefore conferring a strong taxonomic potential. Inconsistencies in the notation and terminology used in discussions of the theropod quadrate anatomy have been noticed, including at least one instance when no less than eight different terms were given to the same structure. A standardized list of terms and notations for each quadrate anatomical entity is proposed here, with the goal of facilitating future descriptions of this important cranial bone. In addition, an overview of the literature on quadrate function and pneumaticity in non-avian theropods is presented, along with a discussion of the inferences that could be made from this research. Specifically, the quadrate of the large majority of non-avian theropods is akinetic but the diagonally oriented intercondylar sulcus of the mandibular articulation allowed both rami of the mandible to move laterally when opening the mouth in many of theropods. Pneumaticity of the quadrate is also present in most averostran clades and the pneumatic chamber—invaded by the quadrate diverticulum of the mandibular arch pneumatic system—was connected to one or several pneumatic foramina on the medial, lateral, posterior, anterior or ventral sides of the quadrate. PMID:26401455
Study made of pneumatic high pressure piping materials /10,000 psi/
NASA Technical Reports Server (NTRS)
Loeb, M. B.; Smith, J. C.
1967-01-01
Evaluations of five types of steel for use in high pressure pneumatic piping systems include tests for impact strength, tensile and yield strengths, elongation and reduction in area, field weldability, and cost. One type, AISI 4615, was selected as most advantageous for extensive use in future flight vehicles.
Pneumatics. Student's Manual [and] Instructor's Guide.
ERIC Educational Resources Information Center
Notgrass, Troy
The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Pneumatic binary encoder replaces multiple solenoid system
NASA Technical Reports Server (NTRS)
1966-01-01
Pneumatic binary encoder replaces solenoid system in the pilot stage of a digital actuator. The encoder operates in flip-flop manner to valve gas at either high or low pressures. By rotating the disk in a pinion-to-encoding gear ratio, six to eight adder circuits may be operated from single encoder.
2003-12-01
potential problem is decreasing the permeability by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air...to increase the biodegradation of the contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as
In Situ Remediation of MTBE-Contaminated Aquifers Using Propane Biosparging
2003-09-01
problem is decreasing the permeability by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air 47 (up to...increase the biodegradation of the contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as high as
DOT National Transportation Integrated Search
1965-10-01
In the early of 1961 a research project was undertaken by the Louisiana Department of Highways in cooperation with the Bureau of Public Roads to study the effect of high intensity pneumatic rollers on the density of asphaltic concrete pavement using ...
Burr, Nick; Lummis, Katie; Sood, Ruchit; Kane, John Samuel; Corp, Aaron; Subramanian, Venkataraman
2017-02-01
Direct oral anticoagulants are increasingly used for a wide range of indications. However, data are conflicting about the risk of major gastrointestinal bleeding with these drugs. We compared the risk of gastrointestinal bleeding with direct oral anticoagulants, warfarin, and low-molecular-weight heparin. For this systematic review and meta-analysis, we searched MEDLINE and Embase from database inception to April 1, 2016, for prospective and retrospective studies that reported the risk of gastrointestinal bleeding with use of a direct oral anticoagulant compared with warfarin or low-molecular-weight heparin for all indications. We also searched the Cochrane Library for systematic reviews and assessment evaluations, the National Health Service (UK) Economic Evaluation Database, and ISI Web of Science for conference abstracts and proceedings (up to April 1, 2016). The primary outcome was the incidence of major gastrointestinal bleeding, with all gastrointestinal bleeding as a secondary outcome. We did a Bayesian network meta-analysis to produce incidence rate ratios (IRRs) with 95% credible intervals (CrIs). We identified 38 eligible articles, of which 31 were included in the primary analysis, including 287 692 patients exposed to 230 090 years of anticoagulant drugs. The risk of major gastrointestinal bleeding with direct oral anticoagulants did not differ from that with warfarin or low-molecular-weight heparin (factor Xa vs warfarin IRR 0·78 [95% CrI 0·47-1·08]; warfarin vs dabigatran 0·88 [0·59-1·36]; factor Xa vs low-molecular-weight heparin 1·02 [0·42-2·70]; and low-molecular-weight heparin vs dabigatran 0·67 [0·20-1·82]). In the secondary analysis, factor Xa inhibitors were associated with a reduced risk of all severities of gastrointestinal bleeding compared with warfarin (0·25 [0.07-0.76]) or dabigatran (0.24 [0.07-0.77]). Our findings show no increase in risk of major gastrointestinal bleeding with direct oral anticoagulants compared with warfarin or low-molecular-weight heparin. These findings support the continued use of direct oral anticoagulants. Leeds Teaching Hospitals Charitable Foundation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Extended and continuous use of hormonal contraceptives to reduce menstruation.
Wiegratz, Inka; Kissler, Stefan; Kuhl, Herbert; Kaufmann, Manfred
2006-09-01
During the use of long-cycle regimens of monophasic oral contraceptives, the total number of bleeding and cycle-dependent complaints is considerably lower than during conventional treatment with oral contraceptives. Despite an initially higher rate of irregular bleeding, the majority of women prefer the long-cycle treatment since it may improve quality of life. As this regimen provides an enhanced ovarian suppression, it may prevent pregnancies, especially in noncompliant women or patients who are concomitantly treated with drugs that may impair the efficacy of oral contraceptives. Postponement or suppression of withdrawal bleeding also reduces menses-associated disorders such as menorrhagia and dysmenorrhea, and has beneficial effects in patients with hemorrhagic diathesis, endometriosis, uterine leiomyomas and polycystic ovary syndrome. Long-term studies are necessary to assess the impact of long-term use of extended regimens of oral contraceptives on safety, for example, the risk of cancer and cardiovascular disease, and on fertility after discontinuation of treatment.
Fanaroff, Alexander; Rao, Sunil
2018-01-01
Platelets play a key role in mediating stent thrombosis, the major cause of ischemic events in the immediate period following percutaneous coronary intervention (PCI). For this reason, antiplatelet therapy, started at the time of PCI and continued for at least 30 days afterwards, is the cornerstone of antithrombotic therapy after PCI. However, the use of antiplatelet agents increase bleeding risk, with more potent antiplatelet agents further increasing bleeding risk. For this reason, balancing prevention of ischemic events with risk of bleeding is fundamental to the effective use of antiplatelet agents. In the past 5 years, potent and fast-acting P2Y12 inhibitors have been introduced, and have augmented the antiplatelet armamentarium available to interventional cardiologists. In this review, we review the preclinical and clinical data surrounding these new agents, and discuss the significant questions and controversies that still exist regarding the optimal antiplatelet strategy. PMID:28582206
[The criteria for choose of treatment method of children with spleen injuries].
Podkamenev, V V; Pikalo, I A
2014-01-01
It was performed cohort prospective study of treatment results of 69 children with through-capsule spleen injuries for the period from 2002 to 2013. Patients were divided into 2 groups. The first group included 63 patients after non-surgical treatment. The second group included 6 children who underwent surgery. In the first group 95.3% of patients had stable hemodynamics at admission. In the second group only 2 patients had the signs of deferred bleeding. Continuing abdominal bleeding was the indication for surgery in 4 patients although stable hemodynamics. Hemoperitoneum in case of spleen injury is not significant prognostic factor defining the tactics of treatment. The physiological response on bleeding but not the amount of blood in abdominal cavity determines tactics of treatment. Hemodynamic status is single statistically significant criterion for choose of surgical treatment of children with spleen injuries. Unstable hemodynamics increases the risk of surgical treatment in 20 times (p<0.007).
Advanced manufacturing development of a composite empennage component for L-1011 aircraft
NASA Technical Reports Server (NTRS)
1978-01-01
Work continued toward the development of tooling and processing concepts required for a cocured hat/skin cover assembly. A plan was developed and implemented to develop the process for using preimpregnated T300/5208 with a resin content of 34 + or - 2 percent by weight. Use of this material results in a simplified laminating process because removal by bleeding or prebleeding is no longer required. The approach to this task basically consists of fabricating and testing flat laminated panels and simulated structural panels to verify known processing techniques relative to end-laminate quality. The flat panels were used to determine air bleeding arrangement and required cure cycle. Single and multihat-stiffened panels were fabricated using the established air bleeding arrangement and cure cycle with the resulting cured parts yielding excellent correlation of ply thickness with all surfaces clear of porosity and voids.
Bevacizumab for Refractory Gastrointestinal Bleeding in Rendu-Osler-Weber Disease
Bernardes, Carlos; Santos, Sara; Loureiro, Rafaela; Borges, Verónica; Ramos, Gonçalo
2018-01-01
Rendu-Osler-Weber disease, also known as hereditary hemorrhagic telangiectasia, is a rare autosomal dominant disorder which is often characterized by recurrent epistaxis, mucocutaneous and gastrointestinal telangiectasias, and visceral arteriovenous malformations. Patients with gastrointestinal involvement can present with a wide spectrum of severity, which may vary from uncomplicated iron deficiency anemia to continuous and refractory bleeding. We present the case of a 62-year-old female, who was admitted with anemia following several episodes of melena, and whose endoscopic examination revealed multiple angiodysplasias in the stomach and small bowel. Despite endoscopic and medical treatment attempts with hormonal agents and octreotide, she developed persistent hemorrhage and severe anemia, requiring frequent red blood cell transfusions. Immediately after initiating bevacizumab (7.5 mg/kg, every 3 weeks), complete cessation of bleeding episodes was observed. Currently, after 1 year of follow-up, she maintained sustained remission without the occurrence of adverse events. PMID:29662934
Dielectric elastomer actuators used for pneumatic valve technology
NASA Astrophysics Data System (ADS)
Giousouf, Metin; Kovacs, Gabor
2013-10-01
Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications.
Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong
2012-11-01
The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.
Microfluidic and Label-Free Multi-Immunosensors Based on Carbon Nanotube Microelectrodes
NASA Astrophysics Data System (ADS)
Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Takamura, Yuzuru; Tamiya, Eiichi
2009-06-01
We fabricated microfluidic and label-free multi-immunosensors by the integration of carbon nanotube (CNT)-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). In the microfluidic systems, four kinds of sample solutions were transported from each liquid inlet to microchannels using six pneumatic micropumps. As a result, two kinds of antibodies were immobilized onto different CNT electrodes using the microfluidic systems. Next, two kinds of cancer markers, prostate specific antigen and human chorionic gonadotropin in phosphate buffer solution, were simultaneously detected by differential pulse voltammetry. Therefore, microfludic multi-immunosensors based on CNT electrodes and pneumatic micropumps are useful for the development of multiplex hand-held biosensors.
Liquid-metal dip seal with pneumatic spring
Poindexter, Allan M.
1977-01-01
An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.
Steuber, Taylor D; Shiltz, Dane L; Cairns, Alex C; Ding, Qian; Binger, Katie J; Courtney, Julia R
2017-11-01
In 2014, the United States Food and Drug Administration approved a labeling change for apixaban to include recommendations for patients with severe renal impairment and patients with end-stage renal disease (ESRD) on hemodialysis (HD), though these recommendations are largely based on pharmacokinetic and pharmacodynamic data. Identify variables associated with bleeding events in hospitalized patients with ESRD on HD receiving apixaban. This retrospective, multicenter cohort study evaluated hospitalized patients with ESRD on HD receiving apixaban from January 1, 2013, through March 31, 2016. Correlational analysis and logistic regression were completed to identify factors associated with bleeding. A total of 114 adults were included in the analysis. The median length of stay (LOS) was 6.2 (interquartile range = 3.8-11.9) days and bleeding events occurred in a total of 17 patients (15%). A weak correlation was identified for higher cumulative apixaban exposure, increased number of HD sessions while receiving apixaban, and increased hospital LOS ( P < 0.05; correlation coefficient < 0.40). When controlling for confounders, logistic regression revealed that composite bleeding events were independently increased by continuation of outpatient apixaban (odds ratio = 13.07; 95% CI = 1.54-110.54; P = 0.018), increased total daily dose of apixaban (odds ratio = 1.72; 95% CI = 1.20 to 2.48; P = 0.003), and total HD sessions while receiving apixaban (odds ratio = 2.04; 95% CI = 1.06-3.92; P = 0.033). The association between these factors and increased bleeding should prompt concern for long-term anticoagulation with apixaban in patients with ESRD receiving chronic HD.
Defining the rectal dose constraint for permanent radioactive seed implantation of the prostate.
Albert, Michele; Song, Jun S; Schultz, Delray; Cormack, Robert A; Tempany, Clare M; Haker, Steve; Devlin, Phillip M; Beard, Clair; Hurwitz, Mark D; Suh, Wonsuk W; Jolesz, Ferenc; D'Amico, Anthony V
2008-01-01
This study was performed to define the rectal dose constraint that would predict late rectal bleeding requiring argon plasma coagulation (APC) following prostate brachy mono-therapy. Between February 1999 and April 2002, 91 patients with low risk prostate cancer underwent permanent I(125) radioactive seed implantation without the use of supplemental external beam radiation or androgen suppression therapy. Patients received both CT and MRI scans 6 weeks postimplant for evaluation of dosimetry. The CT and MRI scans were fused. Rectal volumes were contoured on the T2 weighted MR images. For those patients requiring APC, the date on which a patient reported rectal bleeding was recorded. A Cox regression analysis was performed to assess whether there was a significant association between the rectal volume (continuous) exceeding 100 Gy time rectal bleeding. Comparisons of estimates of rectal bleeding requiring APC were made using a 2-sided log rank test. There was a significant association (hazard ratio = 5.6 [95% confidence interval: 1.3, 23.8]; P = 0.002) between the rectal volume exceeding 100 Gy and rectal bleeding requiring APC. After a median follow-up of 4.25 (1-6) years, no patient with less than a median value of 8 cc of rectum exceeding 100 Gy required APC, whereas 20% (P = 0.004) were estimated to require APC within 3 years following treatment. Keeping the rectal volume receiving more than 100 Gy below 8 cc will minimize the risk of rectal bleeding requiring APC following I(125) permanent prostate brachy mono-therapy.
Gasse, Christiane; Hollowell, Jennifer; Meier, Christoph R; Haefeli, Walter E
2005-09-01
Although drug interactions with warfarin are an important cause of excessive anticoagulation, their impact on the risk of serious bleeding is unknown. We therefore performed a cohort study and a nested case-control analysis to determine the risk of serious bleeding in 4152 patients (aged 40-84 years) with nonvalvular atrial fibrillation (AF) taking long-term warfarin (> 3 months). The study population was drawn from the UK General Practice Research Database. More than half (58%) of eligible patients used potentially interacting drugs during continuous warfarin treatment. Among 45 identified cases of incident idiopathic bleeds (resulting in hospitalisation within 30 days or death within 7 days) and 143 matched controls, more cases than controls took > or = 1 potentially interacting drug within the preceding 30 days (62.2% vs. 35.7%) and used > 4 drugs (polypharmacy) within the preceding 90 days (80.0% vs. 66.4%). Conditional logistic regression analysis yielded an odds ratio (OR) of 3.4 (95% confidence interval [CI]: 1.4-8.5) for the risk of serious bleeding in patients treated with warfarin and > or = 1 drugs potentially increasing the effect of warfarin vs. warfarin alone adjusted for polypharmacy, diabetes, hypertension, heart failure, and thyroid disease; the adjusted OR for the combined use of warfarin and aspirin vs. warfarin alone was 4.5 (95% CI: 1.1-18.1). We conclude that concurrent use of potentially interacting drugs with warfarin is associated with a 3 to 4.5-fold increased risk of serious bleeding in long-term warfarin users.
Yam, Felix K.
2017-01-01
Despite the evidence that some commonly used Chinese medications (CMs) have antiplatelet/anticoagulant effects, many patients still used antiplatelets combined with CMs. We conducted a nested case-crossover study to examine the associations between the concomitant use of antiplatelets and CMs and major bleeding using population-based health database in Taiwan. Among the cohort of 79,463 outpatients prescribed antiplatelets (e.g., aspirin and clopidogrel) continuously, 1,209 patients hospitalized with new occurring bleeding in 2012 and 2013 were included. Those recruited patients served as their own controls to compare different times of exposure to prespecified CMs (e.g., Asian ginseng and dong quai) and antiplatelet agents. The periods of case, control 1, and control 2 were defined as 1–4 weeks, 6–9 weeks, and 13–16 weeks before hospitalization, respectively. Conditional logistic regression analyses found that concurrent use of antiplatelet drugs with any of the prespecified CMs in the case period might not significantly increase the risks of bleeding over that in the control periods (OR = 1.00, 95% CI 0.51 to 1.95 and OR = 1.13, 95% CI 0.65 to 1.97). The study showed no strong relationships between hospitalization for major bleeding events and concurrent use of antiplatelet drugs with the prespecified CMs. PMID:28831288
Weisberg, Edith; Bateson, Deborah; McGeechan, Kevin; Mohapatra, Lita
2014-02-01
BACKGROUND Long-acting reversible contraceptive methods (LARCs) are safe, highly effective, readily reversible, and require no action on the part of the user following insertion. Early discontinuation may put women at increased risk of unintended pregnancy. METHODS Following insertion of a progestogen-only subdermal implant or intrauterine system (IUS) at Family Planning NSW, women 18 years and older completed a questionnaire about their choice. At 6 weeks, 6, 12, 24 and 36 months by telephone or online they completed a questionnaire about bleeding patterns, side effects, satisfaction, and reasons for discontinuation. RESULTS Two hundred IUS users and 149 implant users were enrolled. The former were generally older, married or in a de-facto relationship, and had children. Forty-seven percent of implant users discontinued within three years compared to 27% of IUS users (p = 0.002). In the first two years amenorrhoea was more frequent in implant users. Frequent bleeding/spotting was more prevalent in the first year of IUS use but over time was twice as prevalent in implant users. Infrequent bleeding/spotting was more common in IUS users. CONCLUSION Both devices are highly effective and acceptable cost-effective methods. While LARCs should be promoted to women of all ages seeking contraception, early discontinuation due to unacceptable bleeding highlights the need for pre-insertion counselling.
Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions
In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (sup...
Distortion Of Pressure Signals In Pneumatic Tubes
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William
1993-01-01
NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.
Evaluation of elastomers as gasket materials in pneumatic and hydraulic systems
NASA Technical Reports Server (NTRS)
Bright, C. W.; Lockhart, B. J.
1972-01-01
In the search for superior materials from which to make gaskets for pneumatic and hydraulic systems, promising materials were selected and tested. The testing was conducted in two phases. Those materials that passed the tests of Phase 1 were tested in Phase 2, and categorized in the order of preference.
49 CFR 195.307 - Pressure testing aboveground breakout tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API Standard 620 and first placed in service after October 2, 2000, hydrostatic and pneumatic testing must be...
The Pneumatic Common: Learning in, with and from the Air
ERIC Educational Resources Information Center
Ford, Derek R.
2015-01-01
Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…
2003-12-01
by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air 47 (up to 175 psi) in to the formation that...contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as high as 2000 psi. Technical questions
The Pneumatic Fracturing Extraction (PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would o...
Inexpensive Dramatic Pneumatic Lift
ERIC Educational Resources Information Center
Morse, Robert A.
2017-01-01
Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article…
NASA Astrophysics Data System (ADS)
Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.
2018-03-01
The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.
DOT National Transportation Integrated Search
1978-12-01
This study is the final phase of a muck pipeline program begun in 1973. The objective of the study was to evaluate a pneumatic pipeline system for muck haulage from a tunnel excavated by a tunnel boring machine. The system was comprised of a muck pre...
Design and Control of a Pneumatically Actuated Transtibial Prosthesis.
Zheng, Hao; Shen, Xiangrong
2015-04-01
This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.