Novel method to sample very high power CO2 lasers: II Continuing Studies
NASA Astrophysics Data System (ADS)
Eric, John; Seibert, Daniel B., II; Green, Lawrence I.
2005-04-01
For the past 28 years, the Laser Hardened Materials Evaluation Laboratory (LHMEL) at the Wright-Patterson Air Force Base, OH, has worked with CO2 lasers capable of producing continuous energy up to 150 kW. These lasers are used in a number of advanced materials processing applications that require accurate spatial energy measurements of the laser. Conventional non-electronic methods are not satisfactory for determining the spatial energy profile. This paper describes continuing efforts in qualifying the new method in which a continuous, real-time electronic spatial energy profile can be obtained for very high power, (VHP) CO2 lasers.
Ambient-temperature co-oxidation catalysts
NASA Technical Reports Server (NTRS)
Upchurch, Billy T.; Schryer, David R.; Brown, Kenneth G.; Kielin, Erik J.
1991-01-01
Oxidation catalysts which operate at ambient temperature were developed for the recombination of carbon monoxide (CO) and oxygen (O2) dissociation products which are formed during carbon dioxide (CO2) laser operation. Recombination of these products to regenerate CO2 allows continuous operation of CO2 lasers in a closed cycle mode. Development of these catalyst materials provides enabling technology for the operation of such lasers from space platforms or in ground based facilities without constant gas consumption required for continuous open cycle operation. Such catalysts also have other applications in various areas outside the laser community for removal of CO from other closed environments such as indoor air and as an ambient temperature catalytic converter for control of auto emissions.
Research on industrial 10kW CO2 laser achieves major breakthrough
NASA Astrophysics Data System (ADS)
1991-01-01
The industrial 10kW CO2 laser is one of the items which the industrially developed nations are competing to develop. This laser is capable of continuous output power of over 10kW and can operate continuously for more than 6 hours. The 10kW CO2 laser developed as a key task of China's 7th Five-Year Plan and all its technological targets such as output power, electrooptical conversion efficiency and primary charging continuous operating time, have reached the level of world advancement, allowing China to enter the ranks of international advancement in the area of laser technology. The industrial 10kW CO2 laser can have wide application in such areas of industry as heat treating, machining, welding and surface treatment in industries such as steel, automobiles, ship building and aircraft manufacturing. For instance, using the high-efficiency laser beams of this 10kW laser to treat rollers, fan blades and automotive cylinder blocks can increase the life of these parts and produce large economic benefits. At present, industrial tests of gear welding is already being done on this 10kW laser.
Extinction of CO2 Laser Radiation Under Adverse Weather Conditions
1982-06-01
System Design 60 a, Gaussian Optics 60 b, Laser Transmissometer 61 4. Measurement Errors 68 VI DISCUSSION OF RESULTS 69 1, Introduction...water soluble aerosols (a 1 106 AFWAL-TR-81 -.1280 TABLE 17 EXTINCTION OF CO2 LASER LINES FOR A CONSTANI RAIN RATE OF 1.82 mm/HR, 22 APRIL, 1935 HOURS...number) Laser Propagation Rain Laser Extinction CO2 Lasers Adverse Weather Aerosol s - 20 RACT (Continue on reverse side If necessary
Shoursheini, S Z; Parvin, P; Sajad, B; Bassam, M A
2009-04-01
In this work, we investigate the enhancement of Cu emission lines of a micro-plasma induced by a Nd:YAG laser due to the thermal effect of simultaneous irradiation by a continuous wave (CW) CO(2) laser. The enhancement of the emission lines was achieved at a higher temperature with minimal distortion of the target when the focal point of the Nd:YAG laser was located approximately 1 mm away from the sample surface.
Prevention of CO2 laser-induced endotracheal tube fires with the laser-guard protective coating.
Sosis, M B; Dillon, F
1992-01-01
To determine how well Laser-Guard protects polyvinyl chloride (PVC) endotracheal tubes from the carbon dioxide (CO2) laser. Bare and Laser-Guard-protected PVC endotracheal tubes were tested with 5 L/min of oxygen (O2) passing through them. Research laboratory of a university-affiliated metropolitan medical center. After moistening the Laser-Guard-protected endotracheal tubes, we subjected the tubes to CO2 laser radiation at 10 and 70 watts until combustion occurred or 60 seconds had elapsed. The bare PVC tube ignited and a "blowtorch" fire occurred after 3 seconds of CO2 laser use at 70 watts. The moistened Laser-Guard-protected PVC endotracheal tubes were not significantly damaged by 1 minute of laser use at 70 watts. Laser-Guard protects the shafts of combustible PVC endotracheal tubes from direct, high-power, continuous CO2 laser radiation.
Subsurface plasma in beam of continuous CO2-laser
NASA Astrophysics Data System (ADS)
Danytsikov, Y. V.; Dymshakov, V. A.; Lebedev, F. V.; Pismennyy, V. D.; Ryazanov, A. V.
1986-03-01
Experiments performed at the Institute of Atomic Energy established the conditions for formation of subsurface plasma in substances by laser radiation and its characteristics. A quasi-continuous CO2 laser emitting square pulses of 0.1 to 1.0 ms duration and 1 to 10 kW power as well as a continuous CO2 laser served as radiation sources. Radiation was focused on spots 0.1 to 0.5 mm in diameter and maintained at levels ensuring constant power density during the interaction time, while the temperature of the target surface was measured continuously. Metals, graphite and dielectric materials were tested with laser action taking place in air N2 + O2 mixtures, Ar or He atmosphere under pressures of 0.01 to 1.0 atm. Data on radiation intensity thresholds for evaporation and plasma formation were obtained. On the basis of these thresholds, combined with data on energy balance and the temperature profile in plasma layers, a universal state diagram was constructed for subsurface plasma with nonquantified surface temperature and radiation intensity coordinates.
The Role of the CO2 Laser and Fractional CO2 Laser in Dermatology
Omi, Tokuya; Numano, Kayoko
2014-01-01
Background: Tremendous advances have been made in the medical application of the laser in the past few decades. Many diseases in the dermatological field are now indications for laser treatment that qualify for reimbursement by many national health insurance systems. Among laser types, the carbon dioxide (CO2) laser remains an important system for the dermatologist. Rationale: The lasers used in photosurgery have wavelengths that differ according to their intended use and are of various types, but the CO2 laser is one of the most widely used lasers in the dermatology field. With its wavelength in the mid-infrared at 10,600 nm, CO2 laser energy is wellabsorbed in water. As skin contains a very high water percentage, this makes the CO2 laser ideal for precise, safe ablation with good hemostasis. In addition to its efficacy in ablating benign raised lesions, the CO2 laser has been reported to be effective in the field of esthetic dermatology in the revision of acne scars as well as in photorejuvenation. With the addition of fractionation of the beam of energy into myriad microbeams, the fractional CO2 laser has offered a bridge between the frankly full ablative indications and the nonablative skin rejuvenation systems of the 2000s in the rejuvenation of photoaged skin on and off the face. Conclusions: The CO2 laser remains an efficient, precise and safe system for the dermatologist. Technological advances in CO2 laser construction have meant smaller spot sizes and greater precision for laser surgery, and more flexibility in tip sizes and protocols for fractional CO2 laser treatment. The range of dermatological applications of the CO2 laser is expected to continue to increase in the future. PMID:24771971
The Role of the CO2 Laser and Fractional CO2 Laser in Dermatology.
Omi, Tokuya; Numano, Kayoko
2014-03-27
Tremendous advances have been made in the medical application of the laser in the past few decades. Many diseases in the dermatological field are now indications for laser treatment that qualify for reimbursement by many national health insurance systems. Among laser types, the carbon dioxide (CO2) laser remains an important system for the dermatologist. The lasers used in photosurgery have wavelengths that differ according to their intended use and are of various types, but the CO2 laser is one of the most widely used lasers in the dermatology field. With its wavelength in the mid-infrared at 10,600 nm, CO2 laser energy is wellabsorbed in water. As skin contains a very high water percentage, this makes the CO2 laser ideal for precise, safe ablation with good hemostasis. In addition to its efficacy in ablating benign raised lesions, the CO2 laser has been reported to be effective in the field of esthetic dermatology in the revision of acne scars as well as in photorejuvenation. With the addition of fractionation of the beam of energy into myriad microbeams, the fractional CO2 laser has offered a bridge between the frankly full ablative indications and the nonablative skin rejuvenation systems of the 2000s in the rejuvenation of photoaged skin on and off the face. The CO2 laser remains an efficient, precise and safe system for the dermatologist. Technological advances in CO2 laser construction have meant smaller spot sizes and greater precision for laser surgery, and more flexibility in tip sizes and protocols for fractional CO2 laser treatment. The range of dermatological applications of the CO2 laser is expected to continue to increase in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foulot, H.; Lefebvre, G.; Jagueux, M.
This experiment investigates CO/sub 2/-laser-induced histological effects on fallopian tubes obtained during hysterectomies in women. Tubal transversal sections were performed at isthmic and ampullar sites. Forty strips were available for histological study of the cut section area. The role of different parameters such as radiation power and beam fractionation (continuous versus pulsed) on tissue lesions was assessed. In tubal microsurgery, the CO/sub 2/ laser can be used as a scalpel with the predominant advantage of minimal tissular alterations. As a result of this study, our recommended parameters are the following: radiation power, 7-10 W; beam focalization zone, 0.2 mm; energymore » density, 20,000-35,000 W/cm2; continuous operation; moving speed, 1 cm/s.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhar, G.C.; Das, S.; Chatterjee, U.
1989-04-17
Synchronous noncollinear upconversion detection is reported for the first time with a Nd:YAG laser in AgGaS/sub 2/. Q-switched pump laser pulses with a repetition rate up to 50 Hz were synchronized with intracavity chopped continuous wave CO/sub 2/ laser pulses. Results were obtained both by tuning the CO/sub 2/ laser and by varying the angle between the laser beams.
Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) Aircraft Measurements of CO2
NASA Technical Reports Server (NTRS)
Christensen, Lance E.; Spiers, Gary D.; Menzies, Robert T.; Jacob, Joseph C.; Hyon, Jason
2011-01-01
The Jet Propulsion Laboratory Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) utilizes Integrated Path Differential Absorption (IPDA) at 2.05 microns to obtain CO2 column mixing ratios weighted heavily in the boundary layer. CO2LAS employs a coherent detection receiver and continuous-wave Th:Ho:YLF laser transmitters with output powers around 100 milliwatts. An offset frequency-locking scheme coupled to an absolute frequency reference enables the frequencies of the online and offline lasers to be held to within 200 kHz of desired values. We describe results from 2009 field campaigns when CO2LAS flew on the Twin Otter. We also describe spectroscopic studies aimed at uncovering potential biases in lidar CO2 retrievals at 2.05 microns.
Room-temperature operation of a Co:MgF2 laser
NASA Technical Reports Server (NTRS)
Welford, D.; Moulton, P. F.
1988-01-01
A normal-mode, pulsed Co:MgF2 laser has been operated at room temperature for the first time. Continuous tuning from 1750 to 2500 nm with pulse energies up to 70 mJ and 46-percent slope efficiency was obtained with a 1338-nm Nd:YAG pump laser.
NASA Technical Reports Server (NTRS)
Keiser, Joseph T.
1989-01-01
The Laser Atmospheric Wind Sounder (LAWS) Program has as one of its goals the development of a satellite based carbon dioxide laser for making wind velocity measurements. The specifications for this laser include the requirement that the laser operate at a repetition rate of 10 Hertz continuously for three years. Earth-based carbon dioxide lasers can operate for only a short time on a single charge of gas because the lasing action causes the CO2 to break down into CO and O2. Therefore, earth-based CO2 lasers are generally operated in a flow through mode in which the spent gas is continually exhausted and fresh gas is continually added. For a satellite based system, however, a recirculation system is desired because it is not practical to send up extra tanks of CO2. A catalyst which could enable a recirculating CO2 laser to function continuously for three years needs to be developed. In the development of a catalyst system there are many variables. Obviously, not all possible formulations can be tested for three years, therefore, an accurate model which is based on the reaction mechanism is needed. The construction of a multistep reaction mechanism is similar to the construction of a jigsaw puzzle. Different techniques each supply a piece of the puzzle and the researcher must put the pieces together. Transmission infrared spectroscopy was shown to be very useful in supplying some of the information needed to elucidate reaction mechanisms. The purpose was to see what kind of information might be obtained about the NASA catalyst using infrared absorption spectroscopy. Approximately 200 infrared spectra of the prototype Pt/tin oxide catalyst and its precursor components are observed under a variety of different conditions. The most significant observations are summarized.
Life problems of dc and RF-excited low-power CW CO2 waveguide lasers
NASA Technical Reports Server (NTRS)
Hochuli, U. E.; Haldemann, P. R.
1986-01-01
A number of different, RF-excited 3-W CW CO2 waveguide lasers have been built. Four of these lasers, after continuously working for 15,000-30,000 h, still yield about 70 percent of their original power output. The design variations cover N2and CO-bearing gas mixtures, as well as internal- and external-capacitively coupled excitation electrodes. A similar laser survived 50,000 5-min-ON/5-min-OFF cycles without significant mirror damage. It was not possible to find suitable cold cathodes that allow the building of longitudinally dc-excited CW CO2 waveguide lasers that work for such extended periods of time.
Mode selection and frequency tuning by injection in pulsed TEA-CO2 lasers
NASA Technical Reports Server (NTRS)
Flamant, P. H.; Menzies, R. T.
1983-01-01
An analytical model characterizing pulsed-TEA-CO2-laser injection locking by tunable CW-laser radiation is presented and used to explore the requirements for SLM pulse generation. Photon-density-rate equations describing the laser mechanism are analyzed in terms of the mode competition between photon densities emitted at two frequencies. The expression derived for pulsed dye lasers is extended to homogeneously broadened CO2 lasers, and locking time is defined as a function of laser parameters. The extent to which injected radiation can be detuned from the CO2 line center and continue to produce SLM pulses is investigated experimentally in terms of the analytical framework. The dependence of locking time on the detuning/pressure-broadened-halfwidth ratio is seen as important for spectroscopic applications requiring tuning within the TEA-laser line-gain bandwidth.
NASA Technical Reports Server (NTRS)
Lin, Bing
2014-01-01
Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc. proposes to use the intensity-modulated, continuous-wave (IM-CW) laser absorption spectrometer (LAS) approach for the ASCENDS mission. Prototype LAS instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space LAS systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW LAS system for the active space CO2 mission ASCENDS.
[Effect of CO2 laser on prostheses used in middle ear surgery].
Szymański, Marcin
2005-01-01
The use of CO2 laser is advocated in primary and revision stapes surgery. The aim of the study was to assess the effect of CO2 laser on stapes prostheses. CO2 laser was applied on several types of stapes prostheses and PORPs, with power settings suggested by the manufacturer (continuous wave, 2 W and 6 W; 0,05 s). Application of the laser on stainless steel or titanium prosthesis did not exert any effect on the structure of the prosthesis. The use of the laser on the Teflon piston caused superficial burning with power 2 W, and melting and holes in the piston with power settings at 6W. Similar plastipore prostheses were melting. Hydroxyapatite PORP shattered after application of the laser energy. Teflon and hydroxyapatite prostheses are easily damaged by the laser energy, therefore applying a laser on them should be avoided. CO2 laser can be used on stainless steel and titanium prostheses without risk of damaging them. However the possibility of transmission of heat to the vestibule has to be taken into consideration.
Upschulte, B L; Sonnenfroh, D M; Allen, M G
1999-03-20
A new laser technology that achieves nearly 100-nm quasi-continuous tuning with only injection-current control in a four-section grating-coupler sampled-reflector laser was used to detect CO and CO(2) simultaneously in room-temperature gas mixtures. The same grating-coupler sampled-reflector laser was used to perform in situ measurements of CO, H(2)O, and OH in the exhaust gases of a CH(4)-air flame. This laser is being evaluated for inclusion in a multispecies combustion-emissions exhaust-analysis sensor, and its operational characteristics as they have an impact on gas sensing are described. Preliminary results suggest that this single laser can be used to replace multilaser sensor configurations for some combustion-emissions monitoring applications.
Application of CO laser for laser balloon angioplasty
NASA Astrophysics Data System (ADS)
Miyamoto, Akira; Sakurada, Masami; Mizuno, Kyoichi; Kurita, Akira; Nakamura, Haruo; Suda, Akira; Arai, Tsunenori; Kikuchi, Makoto
1990-07-01
CO laser may be efficient for thermal fusion of intima of arterial wall without adventitial tissue damage because of high tissue absorption. To investigate the efficacy of CO laser as a laser bam for laser balloon angioplasty (LBA). CO laser was irradiated to aortic tissue through 3Oim polyethylene membrane and tissue temperature was measured by a thermistor. At 2Owatt/cm2 200joules/cm2 continuous laser exposure (CE), tissue temperature was above 100°C within a depth of 1mm and rapidly decreased to 60 °C or below between 2 and 3mm in depth. Moreover, adventitial temperature could be decreased by changing duty ratio (exposure duration/interval) of intermittent laser exposure (IE) despite of the same laser energy. Light microscopy showed high degree of medial coagulation necrosis in CE, however thermal coagulation was observed only at the surface of intima of aortic tissue in IE at duty ratio 1 / 2. These findings suggested CO laser could coagulate intimal layer with less deep thermal damage compared to Nd- YAG laser and that IE was better for superficial welding than CE at the same energy. We concluded that CO laser might be more efficient as a laser beam for LBA than Nd-YAG laser.
Closed cycle electric discharge laser design investigation
NASA Technical Reports Server (NTRS)
Baily, P. K.; Smith, R. C.
1978-01-01
Closed cycle CO2 and CO electric discharge lasers were studied. An analytical investigation assessed scale-up parameters and design features for CO2, closed cycle, continuous wave, unstable resonator, electric discharge lasing systems operating in space and airborne environments. A space based CO system was also examined. The program objectives were the conceptual designs of six CO2 systems and one CO system. Three airborne CO2 designs, with one, five, and ten megawatt outputs, were produced. These designs were based upon five minute run times. Three space based CO2 designs, with the same output levels, were also produced, but based upon one year run times. In addition, a conceptual design for a one megawatt space based CO laser system was also produced. These designs include the flow loop, compressor, and heat exchanger, as well as the laser cavity itself. The designs resulted in a laser loop weight for the space based five megawatt system that is within the space shuttle capacity. For the one megawatt systems, the estimated weight of the entire system including laser loop, solar power generator, and heat radiator is less than the shuttle capacity.
Corona Preionization Technique for Carbon Dioxide TEA Lasers.
1982-11-30
34’" " " " "- -. .. " "I~ 82R8O701-02 CORONA PREIONIZATION TECHNIQUE FOR CARBON DIOXIDE TEA LASERS W after R. Kamnki SUnited Technologiles Research Center C...TITLE (and Subtitle) S. TYPE OF REPORT a PERIOD COVERED CORONA PREIONIZATION TECHNIQUE FOR CARBON Final Report DIOXIDE TEA LASERS May 5, 1981...Preionization Laser UV Preionization Pulsed CO2 Laser Corona Preionization CO2 TEA Laser 10. ABSTRACT (Continue on reverse side If neceeeiny md Identify
Suter, Valérie G A; Altermatt, Hans Jörg; Sendi, Pedram; Mettraux, Gérald; Bornstein, Michael M
2010-01-01
The present pilot study evaluates the histopathological characteristics and suitability of CO2 and diode lasers for performing excisional biopsies in the buccal mucosa with special emphasis on the extent of the thermal damage zone created. 15 patients agreed to undergo surgical removal of their fibrous hyperplasias with a laser. These patients were randomly assigned to one diode or two CO2 laser groups. The CO2 laser was used in a continuous wave mode (cw) with a power of 5 W (Watts), and in a pulsed char-free mode (cf). Power settings for the diode laser were 5.12 W in a pulsed mode. The thermal damage zone of the three lasers and intraoperative and postoperative complications were assessed and compared. The collateral thermal damage zone on the borders of the excisional biopsies was significantly smaller with the CO, laser for both settings tested compared to the diode laser regarding values in pm or histopathological index scores. The only intraoperative complication encountered was bleeding, which had to be controlled with electrocauterization. No postoperative complications occurred in any of the three groups. The CO2 laser seems to be appropriate for excisional biopsies of benign oral mucosal lesions. The CO2 laser offers clear advantages in terms of smaller thermal damage zones over the diode laser. More study participants are needed to demonstrate potential differences between the two different CO2 laser settings tested.
Temple, P A; Lowdermilk, W H; Milam, D
1982-09-15
Mechanically polished fused silica surfaces were heated with continuous-wave CO(2) laser radiation. Laser-damage thresholds of the surfaces were measured with 1064-nm 9-nsec pulses focused to small spots and with large-spot, 1064-nm, 1-nsec irradiation. A sharp transition from laser-damage-prone to highly laser-damage-resistant took place over a small range in CO(2) laser power. The transition to high damage resistance occurred at a silica surface temperature where material softening began to take place as evidenced by the onset of residual strain in the CO(2) laser-processed part. The small-spot damage measurements show that some CO(2) laser-treated surfaces have a local damage threshold as high as the bulk damage threshold of SiO(2). On some CO(2) laser-treated surfaces, large-spot damage thresholds were increased by a factor of 3-4 over thresholds of the original mechanically polished surface. These treated parts show no obvious change in surface appearance as seen in bright-field, Nomarski, or total internal reflection microscopy. They also show little change in transmissive figure. Further, antireflection films deposited on CO(2) laser-treated surfaces have thresholds greater than the thresholds of antireflection films on mechanically polished surfaces.
A radiatively pumped CW CO2 laser
NASA Technical Reports Server (NTRS)
Insuik, R. J.; Christiansen, W. H.
1984-01-01
A proof of principle experiment to demonstrate the physics of a radiatively pumped laser has been carried out. For the first time, a blackbody cavity has optically pumped a CW CO2 laser. Results are presented from a series of experiments using mixtures of CO2, He, and Ar in which maximum output power was obtained with a 20 percent CO2-15 percent He-65 percent Ar mixture. The dependence of the output power on the blackbody temperature and the cooling gas flow rate is also discussed. By appropriately varying these parameters, continuous output powers of 8-10 mW have been achieved.
Pulpotomies with CO2 laser in dogs
NASA Astrophysics Data System (ADS)
Figueiredo, Jose A. P.; Chavantes, Maria C.; Gioso, Marco A.; Pesce, Hildeberto F.; Jatene, Adib D.
1995-05-01
The aim of this study was to evaluate the clinical aspects of dental pulps submitted to shallow pulpotomy followed by CO2 laser radiation at five different procedures. For this purpose, initially 66 dogs' teeth were opened and about 2 or 3 mm of coronal dental pulp was removed. Continuous irrigation with saline solution was implemented. The teeth were randomly divided into 6 groups of 11 each. After cessation of bleeding, in group I, CO2 laser (Xanar-20, USA) was irradiated for 1 second at a power of 5 watts; in group II, 2 seconds at 3 watts; in Group III, 2 seconds at 5 watts; in Group IV, 1 second at 3 watts; in Group V, a continuous mode at 3 watts; Group VI served as a control, with no laser irradiation. The results showed no clinical differences between the 3 W and 5 W powers. Time period of irradiation exposition influenced definitively the clinical appearance of the dental pulps. Groups I and IV (1 second) were unable to stop the bleeding, which persisted over 15 minutes for all teeth. This may be due to the intense heat generated by CO2 laser, causing vasodilatation. Groups II and III displayed a similar appearance, but bleeding stopped in about 10 minutes. Group V (continuous mode) had no bleeding after irradiation, but a plasma-like liquid would come out for almost 2 minutes. When comparing to the control (Group VI), all the pulps would assume a jelly-like aspect, with black granulated tissue on the surface, covering totally the pulps of Group V and partially the other groups. The histological results will be discussed in a further study. From the data obtained, it seems that CO2 laser irradiation for pulpotomies should be done in a continuous mode, for clinical convenience in terms of time taken and effective irradiation.
NASA Astrophysics Data System (ADS)
Rao, Zhiming; He, Zhifang; Du, Jianqiang; Zhang, Xinyou; Ai, Guoping; Zhang, Chunqiang; Wu, Tao
2012-03-01
This paper applied numerical simulation of temperature by using finite element analysis software Ansys to study a model of drilling on sticking plaster. The continuous CO2 laser doing uniform linear motion and doing uniform circular motion irradiated sticking plaster to vaporize. The sticking plaster material was chosen as the thermal conductivity, the heat capacity and the density. For temperatures above 450 °C, sticking plaster would be vaporized. Based on the mathematical model of heat transfer, the process of drilling sticking plaster by laser beams could be simulated by Ansys. The simulation results showed the distribution of the temperature at the surface of the sticking plaster with the time of vaporizing at CO2 laser to do uniform linear motion and to do uniform circular motion. The temperature of sticking plaster CO2 laser to do uniform linear motion was higher than CO2 laser to do uniform circular motion in the same condition.
NASA Astrophysics Data System (ADS)
Ishii, K.; Watanabe, S.; Obata, D.; Hazama, H.; Morita, Y.; Matsuoka, Y.; Kutsumi, H.; Azuma, T.; Awazu, K.
2010-02-01
Endoscopic submucosal dissection (ESD) is accepted as a minimally invasive treatment technique for small early gastric cancers. Procedures are carried out using some specialized electrosurgical knifes with a submucosal injection solution. However it is not widely used because its procedure is difficult. The objective of this study is to develop a novel ESD method which is safe in principle and widely used by using laser techniques. In this study, we used CO2 lasers with a wavelength of 10.6 μm for mucosal ablation. Two types of pulse, continuous wave and pulsed wave with a pulse width of 110 ns, were studied to compare their values. Porcine stomach tissues were used as a sample. Aqueous solution of sodium hyaluronate (MucoUpR) with 50 mg/ml sodium dihydrogenphosphate is injected to a submucosal layer. As a result, ablation effect by CO2 laser irradiation was stopped because submucosal injection solution completely absorbed CO2 laser energy in the invasive energy condition which perforates a muscle layer without submucosal injection solution. Mucosal ablation by the combination of CO2 Laser and a submucosal injection solution is a feasible technique for treating early gastric cancers safely because it provides a selective mucosal resection and less-invasive interaction to muscle layer.
2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement
NASA Technical Reports Server (NTRS)
Singh, Upendra N.; Bai, Yingxin; Yu, Jirong
2009-01-01
Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed in NASA Langley Research Center. This laser system is capable of making a vertical profiling of CO2 from ground and column measurement of CO2 from air and space-borne platform. The transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. A Ho:YLF laser operating in the range of 2.05 micrometers can be tuned over several characteristic lines of CO2 absorption. Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of CO2 with a repetition rate of 5 Hz and pulse energy of 75 mJ. For coherent detection, high repetition rate is required for speckle averaging to obtain highly precise measurements. However, a diode pumped Ho:Tm:YLF laser can not operate in high repetition rate due to the large heat loading and up-conversion. A Tm:fiber laser pumped Ho:YLF laser with low heat loading can operate in high repetition rate. A theoretical model has been established to simulate the performance of Tm:fiber laser pumped Ho:YLF lasers. For continuous wave (CW) operation, high pump intensity with small beam size is suitable for high efficiency. For Q-switched operation, the optimal energy extraction relies on the pump intensity, pump volume, and pump duration which is inversely proportion to the repetition rate. CW and Q-switched Ho:YLF lasers with different linear cavity configurations have been designed and demonstrated for a 30 W Tm:fiber pump laser. The CW Ho laser slope efficiency and optical-to-optical efficiencies reach 65% and 55%, respectively. The pulsed laser efficiency depends on the repetition rate. For 1 kHz operation, the optical-to-optical efficiency is 39% when the pump power is 14.5W. Currently, the injection seeding success rate is between 99.4% and 99.95%. After a ten thousand pulses, the standard deviation of the laser frequency jitter is about 3 MHz. It meets the requirements of highly precise CO2 concentration measurement. In conclusion, an injection seeded, high repetition rate, Q-switched Ho:YLF laser has been developed for a coherent CO2 differential absorption lidar. This master-slave laser system has high optical-to-optical efficiency and seeding success rate. It can potentially meet the requirements of the coherent detection of CO2 concentration by a differential absorption lidar technique.
Effects of laser-aided circumferential supracrestal fiberotomy on root surfaces.
Lee, Ji-Won; Park, Ki-Ho; Chung, Jong-Hyuk; Kim, Su-Jung
2011-11-01
To evaluate and compare the effects of circumferential supracrestal fiberotomy in vivo (using diode, CO(2), and Er∶YAG lasers) on the morphology and chemical composition of the root surface. Forty healthy premolar teeth, intended for extraction for orthodontic reasons, were used in this study. Root surfaces were treated using different laser methods, as follows: (1) control; (2) Er∶YAG laser (2.94 µm, 100 mJ, 10 Hz); (3) diode laser (808 nm, 1.2 W, continuous wave); and (4) CO(2) laser (10.6 µm, 3 W, continuous wave). Subsequently, the teeth were removed and subjected to scanning electron microscopic (SEM) examination and energy dispersive x-ray (EDX) spectrometric analysis. SEM analysis indicated that no thermal changes, including melting or carbonization, were observed following the lasing procedures. EDX analysis showed that the laser procedures resulted in similar mineral contents (weight % of calcium and phosphate) as compared to those in the control group. Based on these findings, we concluded that laser-aided procedures, when used at appropriate laser settings, preserve the original morphology and chemical composition of cementum.
Removal of dogs' gingival pigmentation with CO2 laser
NASA Astrophysics Data System (ADS)
Figueiredo, Jose A. P.; Chavantes, Maria C.; Gioso, Marco A.; Pesce, Hildeberto F.; Jatene, Adib D.
1995-05-01
The aim of this study was to analyze the ability of CO2 laser to remove physiologic pigmentation of gingiva. Dogs were chosen for this study because of their intense black pigmentation on the gingiva, similar to what can be found in human negroes and other dark- skinned races. Three specimens were irradiated at the left side of the buccal aspect of the gingiva, while for comparison the right side was used as a control. CO2 laser in a continuous mode applying 3 watt power was used (Xanar-20, USA). The portion to be irradiated was continuously irrigated with saline solution, to prevent tissue damage from the excessive heat generated. The handpiece device irradiated the target easily and fast, with no bleeding. All the pigmentation could be removed from the portion exposed to the laser beam. A 45th day follow up showed very little repigmentation just in one of the specimens. It could be concluded that CO2 laser irradiation can be an alternative to remove pigmentation of the gingiva for cosmetic purposes. The risk of repigmentation exists, so the patients should be aware of this inconvenience, sometimes demanding further irradiation.
Miniaturized Laser Heterodyne Radiometer for Measurements of CO2 in the Atmospheric Column
NASA Technical Reports Server (NTRS)
Wilson, E. L.; Mclinden, M. L.; Miller, J. H.; Allan, G. R.; Lott, L. E.; Melroy, H. R.; Clarke, G. B.
2013-01-01
We have developed a low-cost, miniaturized laser heterodyne radiometer for highly sensitive measurements of carbon dioxide (CO2) in the atmospheric column. In this passive design, sunlight that has undergone absorption by CO2 in the atmosphere is collected and mixed with continuous wave laser light that is step-scanned across the absorption feature centered at 1,573.6 nm. The resulting radio frequency beat signal is collected as a function of laser wavelength, from which the total column mole fraction can be de-convolved. We are expanding this technique to include methane (CH4) and carbon monoxide (CO), and with minor modifications, this technique can be expanded to include species such as water vapor (H2O) and nitrous oxide (N2O).
CO 2 laser cutting of MDF . 1. Determination of process parameter settings
NASA Astrophysics Data System (ADS)
Lum, K. C. P.; Ng, S. L.; Black, I.
2000-02-01
This paper details an investigation into the laser processing of medium-density fibreboard (MDF). Part 1 reports on the determination of process parameter settings for the effective cutting of MDF by CO 2 laser, using an established experimental methodology developed to study the interrelationship between and effects of varying laser set-up parameters. Results are presented for both continuous wave (CW) and pulse mode (PM) cutting, and the associated cut quality effects have been commented on.
NASA Technical Reports Server (NTRS)
Brown, Kenneth G.; Sidney, B. D.; Schryer, D. R.; Upchurch, B. T.; Miller, I. M.
1986-01-01
This paper reports results on recombination of pulsed CO2 laser dissociation products with Pt/SnO2 catalysts, and supporting studies in a surrogate laboratory catalyst reactor. The closed-cycle, pulsed CO2 laser has been continuously operated for one million pulses with an overall power degradation of less than 5 percent by flowing the laser gas mixture through a 2-percent Pt/SnO2 catalyst bed. In the surrogate laboratory reactor, experiments have been conducted to determine isotopic exchange with the catalyst when using rare-isotope gases. The effects of catalyst pretreatment, sample weight, composition, and temperature on catalyst efficiency have also been determined.
Solar pumped continuous wave carbon dioxide laser
NASA Technical Reports Server (NTRS)
Yesil, O.; Christiansen, W. H.
1978-01-01
In an effort to demonstrate the feasibility of a solar pumped laser concept, gain has been measured in a CO2-He laser medium optically pumped by blackbody radiation. Various gas mixtures of CO2 and He have been pumped by blackbody radiation emitted from an electrically heated oven. Using a CO2 laser as a probe, an optical gain coefficient of 1.8 x 10 to the -3rd/cm has been measured at 10.6 microns for a 9:1 CO2-He mixture at an oven temperature of about 1500 K, a gas temperature of about 400 K and a pressure of about 1 torr. This corresponds to a small signal gain coefficient when allowance is made for saturation effects due to the probe beam, in reasonable agreement with a theoretical value.
Wavelength Locking to CO2 Absorption Line-Center for 2-Micron Pulsed IPDA Lidar Application
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Petros, Mulugeta; Antill, Charles W.; Singh, Upendra N.; Yu, Jirong
2016-01-01
An airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This IPDA lidar system targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements. Independent wavelength control of each of the transmitted laser pulses is a key feature for the success of this instrument. The wavelength control unit provides switching, tuning and locking for each pulse in reference to a 2-micron CW (Continuous Wave) laser source locked to CO2 line-center. Targeting the CO2 R30 line center, at 2050.967 nanometers, a wavelength locking unit has been integrated using semiconductor laser diode. The CO2 center-line locking unit includes a laser diode current driver, temperature controller, center-line locking controller and CO2 absorption cell. This paper presents the CO2 center-line locking unit architecture, characterization procedure and results. Assessment of wavelength jitter on the IPDA measurement error will also be addressed by comparison to the system design.
First field determination of the 13C/12C isotope ratio in volcanic CO2 by diode-laser.
Castrillo, A; Casa, G; van Burgel, M; Tedesco, D; Gianfrani, L
2004-12-27
Carbon isotope ratio analysis using a laser-based technique has been performed in the field, on the gaseous emissions from an active volcano. We here describe that 13CO2/12CO2 determinations can be carried out in a quasi-continuous regime using a compact, selective and sensitive diode laser spectrometer at a wavelength of 2 mum. Within the Solfatara crater (near Naples, Italy), in a very harsh environment, we were able to determine relative 13CO2/12CO2 values, on the highest flux fumarole, with an accuracy of 0.5 per thousand. Regular and frequent observations of the carbon isotopes in volcanic gases, which become possible with our methodology, are of the utmost importance for geochemical surveillance of volcanoes.
Clinical uses of CO2 laser in plastic surgery.
Bronz, G
2001-01-01
The author demonstrates what can be done with the CO2 laser in the ultrapulse mode and in the continuous wave mode. In his four and a half years of experience he has seen that the result one gets after six months lasts for a longer time. If, after this time, the result is not satisfactory for the patient and for the surgeon, he offers a new laser treatment free of charge.
Mass Spectrometry of the CO2 Laser Plasma.
1981-06-01
Lasers Plasma Chemistry Discharge Electrochemistry 20. ABSTRACT (Continue on reverse side If necessary end identify by block number) ... The neutral and...Reference 3). The evidence indicates that valuable information concerning the plasma chemistry of the discharge can be obtained with the aid of a mass...gives very reliable results as will be shown later. The ultimate goal of this project was to investigate the plasma chemistry of the CO2 laser discharge
Donnez, J; Nisolle, M
1989-09-01
Used endoscopically, the CO2 laser offers some advantages over other operative techniques for endometriosis and adhesions but, in spite of the continuing development of new instrumentation there are still problems with the system. The technique needs specialized equipment requiring ongoing biomedical maintenance and specialized technical care in the operating room. Some problems such as the intraperitoneal accumulation of smoke, gas leakage, and difficulty with maintenance of proper beam alignment still occur. In spite of these problems the advantages are numerous: the system allows precise bloodless destruction of diseased tissue and eliminates the risks of cautery. In the hands of an experienced laparoscopist, it appears safe and effective in vaporization of endometriotic lesions, utero-sacral neurectomy, adhesiolysis and salpingostomy. The judicious use of these techniques, combined with carefully planned further investigations by well-trained and experienced laparoscopists and continuing improvements in the delivery systems, will soon reveal the true efficacy of the CO2 laser laparoscope. If studies continue to show pregnancy rates and pain relief to be equivalent to those patients treated by laparotomy, CO2 laser laparoscopy will become the preferred procedure for the management of pelvic endometriosis and its associated adhesions, distal tubal occlusion, pelvic pain and tubal pregnancy. With the exception of using the argon laser to treat endometriosis, the selective absorption characteristic of lasers has not been greatly utilized. While the CO2 laser is heavily absorbed by water and hence vaporizes most cells in a rather indiscriminate fashion, this is not true for other wavelengths, such as argon, Nd-YAG, KTP, krypton, xenon, copper and gold vapour lasers. The energy form of each of these lasers has different properties of penetration, absorption, reflection and heat dissipation. Many of these lasers have not yet been evaluated in human subjects. An exciting, although not new, area of possible laser application involves the use of photosensitizers and fluorescing agents (Dougherty et al, 1978). Some recent experimental studies (Schellhas and Schneider, 1986; Schneider et al, 1988) may lead to new therapeutic possibilities. The surgical laser is not, however, a panacea. Only controlled trials carried out carefully over the next few years will clearly define its potential. In the meantime it is incumbent upon all of us to investigate the clinical, gynaecological and surgical applications in a careful, methodical and scientific manner.
Highly efficient continuous-wave laser operation of LD-pumped Nd,Gd:CaF2 and Nd,Y:CaF2 crystals
NASA Astrophysics Data System (ADS)
Pang, Siyuan; Ma, Fengkai; Yu, Hao; Qian, Xiaobo; Jiang, Dapeng; Wu, Yongjing; Zhang, Feng; Liu, Jie; Xu, Jiayue; Su, Liangbi
2018-05-01
Spectroscopic properties of Nd:CaF2 crystals are investigated. The photoluminescence intensity in the near infrared region is drastically enhanced by co-doping Gd3+ ions and Y3+ in Nd:CaF2 crystals. Preliminary laser experiments are carried out with 0.3%Nd,5%Gd:CaF2 and 0.3%Nd,5%Y:CaF2 crystals under laser diode pumping; true continuous wave laser operation is achieved with slope efficiencies of 42% and 39%, respectively, and the maximum output power reaches 1.188 W.
Effect of a target on the stimulated emission of microsecond CO2-laser pulses
NASA Astrophysics Data System (ADS)
Baranov, V. Iu.; Dolgov, V. A.; Maliuta, D. D.; Mezhevov, V. S.; Semak, V. V.
1987-12-01
The paper reports a change in the pulse shape of a TEA CO2 laser with an unstable cavity under the interaction between the laser radiation and a metal surface in the presence of a breakdown plasma. It is shown that a continuous change in the phase difference between the wave reflected in the cavity and the principal cavity wave gives rise to changes in the pulse shape and the appearance of power fluctuations. The possible effect of these phenomena on the laser treatment of materials is considered.
Surface treatment of dental porcelain: CO2 laser as an alternative to oven glaze.
Sgura, Ricardo; Reis, Mariana Cavalcante; Hernandes, Antonio Carlos; de Abreu Fantini, Márcia Carvalho; Andreeta, Marcello Rubens Barsi; Medeiros, Igor Studart
2015-02-01
This work tested continuous CO2 laser as a surface treatment to dental porcelain and compared it to oven glaze (auto-glaze) by means of roughness and color parameters. Three commercial veneering porcelains with different crystalline content were tested: VM7, VM9, and VM13. Porcelain discs (3.5 × 2.0 mm, diameter × height) were sintered and had one side ground by a diamond bur (45 μm) simulating a chairside adjustment in a clinical office. Specimens (n = 7) were divided into the following groups: C--control (no treatment), G--auto-glaze (oven), and L--surface continuous irradiation with CO2 laser (Gem Laser, Coherent; λ = 10.6 μm). Laser was tested in three exposure times (3, 4, or 5 min) and two irradiances (45 and 50 W/cm(2)). Roughness parameters (Ra, Rz, and Rpm/Rz) were measured using a rugosimeter (Surftest 301, Mitutoyo). Color differences (ΔE) between the G and L groups were calculated (VITA Easyshade); ΔE values up to 3.3 were considered as not perceivable. A surface analysis was conducted by stereomicroscopy (Olympus SZ61) and SEM (Stereoscan 440, LEO). Crystalline content of specimens from groups C and L (50 W/cm(2), 5 min) was assessed by X-ray diffraction and then compared. Surface roughness (Ra and Rz) observed for laser-irradiated groups was similar to G for all studied porcelains. Rpm/Rz ratios were near 1.0 for all groups that indicated a sharp ridge profile for all specimens. Only one laser condition studied (50 W/cm(2), 3 min) from VM7 porcelain resulted in color difference (ΔE = 3.5) to G. Specimens irradiated with 50 W/cm(2) for 5 min presented the smoother surface observed by SEM, comparable to G. X-ray diffraction data revealed an increase in leucite crystallite size for VM9 and VM13 porcelains after laser treatment. Regarding roughness, continuous CO2 laser applied on porcelain surface was as effective as conventional oven auto-glaze.
NASA Astrophysics Data System (ADS)
Chao, Xing; Jeffries, Jay B.; Hanson, Ronald K.
2013-03-01
A real-time, in situ CO sensor using 2.3 μm DFB diode laser absorption, with calibration-free wavelength-modulation-spectroscopy, was demonstrated for continuous monitoring in the boiler exhaust of a pulverized-coal-fired power plant up to temperatures of 700 K. The sensor was similar to a design demonstrated earlier in laboratory conditions, now refined to accommodate the harsh conditions of utility boilers. Measurements were performed across a 3 m path in the particulate-laden economizer exhaust of the coal-fired boiler. A 0.6 ppm detection limit with 1 s averaging was estimated from the results of a continuous 7-h-long measurement with varied excess air levels. The measured CO concentration exhibited expected inverse trends with the excess O2 concentration, which was varied between 1 and 3 %. Measured CO concentrations ranged between 6 and 200 ppm; evaluation of the data suggested a dynamic range from 6 to 10,000 ppm based on a minimum signal-to-noise ratio of ten and maximum absorbance of one. This field demonstration of a 2.3 μm laser absorption sensor for CO showed great potential for real-time combustion exhaust monitoring and control of practical combustion systems.
[Open-path online monitoring of ambient atmospheric CO2 based on laser absorption spectrum].
He, Ying; Zhang, Yu-Jun; Kan, Rui-Feng; Xia, Hui; Geng, Hui; Ruan, Jun; Wang, Min; Cui, Xiao-Juan; Liu, Wen-Qing
2009-01-01
With the conjunction of tunable diode laser absorption spectroscopy technology (TDLAS) and the open long optical path technology, the system designing scheme of CO2 on-line monitoring based on near infrared tunable diode laser absorption spectroscopy technology was discussed in detail, and the instrument for large-range measurement was set up. By choosing the infrared absorption line of CO2 at 1.57 microm whose line strength is strong and suitable for measurement, the ambient atmospheric CO2 was measured continuously with a 30 s temporal resolution at an suburb site in the autumn of 2007. The diurnal atmospheric variations of CO2 and continuous monitoring results were presented. The results show that the variation in CO2 concentration has an obvious diurnal periodicity in suburb where the air is free of interference and contamination. The general characteristic of diurnal variation is that the concentration is low in the daytime and high at night, so it matches the photosynthesis trend. The instrument can detect gas concentration online with high resolution, high sensitivity, high precision, short response time and many other advantages, the monitoring requires no gas sampling, the calibration is easy, and the detection limit is about 4.2 x 10(-7). It has been proved that the system and measurement project are feasible, so it is an effective method for gas flux continuous online monitoring of large range in ecosystem based on TDLAS technology.
Pulsed solid state lasers for medicine
NASA Astrophysics Data System (ADS)
Kertesz, Ivan; Danileiko, A. Y.; Denker, Boris I.; Kroo, Norbert; Osiko, Vyacheslav V.; Prokhorov, Alexander M.
1994-02-01
The effect on living tissues of different pulsed solid state lasers: Nd:YAG ((lambda) equals 1.06 micrometers ) Er:glass (1.54 micrometers ), Ho:YAG (2.1 micrometers ) and Er:YAG (2.94 micrometers ) is compared with the continuous wave Nd:YAG- and CO2-lasers used in operating theaters. Portable Er:glass- and Er:YAG-lasers are developed for surgery/cosmetics and HIV-safe blood testing.
van Geldern, Robert; Nowak, Martin E; Zimmer, Martin; Szizybalski, Alexandra; Myrttinen, Anssi; Barth, Johannes A C; Jost, Hans-Jürg
2014-12-16
A newly developed isotope ratio laser spectrometer for CO2 analyses has been tested during a tracer experiment at the Ketzin pilot site (northern Germany) for CO2 storage. For the experiment, 500 tons of CO2 from a natural CO2 reservoir was injected in supercritical state into the reservoir. The carbon stable isotope value (δ(13)C) of injected CO2 was significantly different from background values. In order to observe the breakthrough of the isotope tracer continuously, the new instruments were connected to a stainless steel riser tube that was installed in an observation well. The laser instrument is based on tunable laser direct absorption in the mid-infrared. The instrument recorded a continuous 10 day carbon stable isotope data set with 30 min resolution directly on-site in a field-based laboratory container during a tracer experiment. To test the instruments performance and accuracy the monitoring campaign was accompanied by daily CO2 sampling for laboratory analyses with isotope ratio mass spectrometry (IRMS). The carbon stable isotope ratios measured by conventional IRMS technique and by the new mid-infrared laser spectrometer agree remarkably well within analytical precision. This proves the capability of the new mid-infrared direct absorption technique to measure high precision and accurate real-time stable isotope data directly in the field. The laser spectroscopy data revealed for the first time a prior to this experiment unknown, intensive dynamic with fast changing δ(13)C values. The arrival pattern of the tracer suggest that the observed fluctuations were probably caused by migration along separate and distinct preferential flow paths between injection well and observation well. The short-term variances as observed in this study might have been missed during previous works that applied laboratory-based IRMS analysis. The new technique could contribute to a better tracing of the migration of the underground CO2 plume and help to ensure the long-term integrity of the reservoir.
Intensity-Modulated Continuous-Wave Lidar at 1.57 Micrometer for Atmospheric CO2 Measurements
NASA Technical Reports Server (NTRS)
Lin, Bing; Ismail, Syed; Browell, Edward; Meadows, Byron; Nehrir, Amin; Harrison, Wallace F.; Dobler, Jeremy; Obland, Michael
2014-01-01
Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc proposes to use the intensity-modulated, continuous-wave (IM-CW) lidar approach for the ASCENDS mission. Prototype instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space lidar systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW lidar system for the active space CO2 mission ASCENDS.
Telle, J.M.
1984-05-01
Apparatus and method for generating continuous wave 16 ..mu..m laser radiation using gaseous CF/sub 4/. Laser radiation at 16 ..mu..m has been observed in a cooled static cell containing low pressure CF/sub 4/ optically pumped by an approximately 3 W output power c-w CO/sub 2/ laser. The laser cavity employed was a multiple-pass off-axis-path two spherical mirror ring resonator. Unidirectional CF/sub 4/ laser output power at 615 cm/sup -1/ exceeded 2 mW. Computer calculations indicate that for modest pump powers of about 40 W, approximately 1 W of emitted laser radiation at 16 ..mu..m might be obtained.
Apparatus and method for generating continuous wave 16 .mu.m laser radiation using gaseous CF.sub.4
Telle, John M.
1986-01-01
Apparatus and method for generating continuous wave 16 .mu.m laser radiation using gaseous CF.sub.4. Laser radiation at 16 .mu.m has been observed in a cooled static cell containing low pressure CF.sub.4 optically pumped by an approximately 3 W output power cw CO.sub.2 laser. The laser cavity employed was a multiple-pass off-axis-path two spherical mirror ring resonator. Unidirectional CF.sub.4 laser output power at 615 cm.sup.-1 exceeded 2 mW. Computer calculations indicate that for modest pump powers of about 40 W, approximately 1 W of emitted laser radiation at 16 .mu.m might be obtained.
Carbon dioxide laser ablation with immediate autografting in a full-thickness porcine burn model.
Glatter, R D; Goldberg, J S; Schomacker, K T; Compton, C C; Flotte, T J; Bua, D P; Greaves, K W; Nishioka, N S; Sheridan, R L
1998-01-01
OBJECTIVE: To compare the long-term clinical and histologic outcome of immediate autografting of full-thickness burn wounds ablated with a high-power continuous-wave CO2 laser to sharply débrided wounds in a porcine model. SUMMARY BACKGROUND DATA: Continuous-wave CO2 lasers have performed poorly as tools for burn excision because the large amount of thermal damage to viable subeschar tissues precluded successful autografting. However, a new technique, in which a high-power laser is rapidly scanned over the eschar, results in eschar vaporization without significant damage to underlying viable tissues, allowing successful immediate autografting. METHODS: Full-thickness paravertebral burn wounds measuring 36 cm2 were created on 11 farm swine. Wounds were ablated to adipose tissue 48 hours later using either a surgical blade or a 150-Watt continuous-wave CO2 laser deflected by an x-y galvanometric scanner that translated the beam over the tissue surface, removing 200 microm of tissue per scan. Both sites were immediately autografted and serially evaluated clinically and histologically for 180 days. RESULTS: The laser-treated sites were nearly bloodless. The mean residual thermal damage was 0.18+/-0.05 mm. The mean graft take was 96+/-11% in manual sites and 93+/-8% in laser sites. On postoperative day 7, the thickness of granulation tissue at the graft-wound bed interface was greater in laser-debrided sites. By postoperative day 180, the manual and laser sites were histologically identical. Vancouver scar assessment revealed no differences in scarring at postoperative day 180. CONCLUSIONS: Long-term scarring, based on Vancouver scar assessments and histologic evaluation, was equivalent at 6 months in laser-ablated and sharply excised sites. Should this technology become practical, the potential clinical implications include a reduction in surgical blood loss without sacrifice of immediate engraftment rates or long-term outcome. Images Figure 1. Figure 2. Figure 3. Figure 4. PMID:9712572
Catalysts for long-life closed-cycle CO2 lasers
NASA Technical Reports Server (NTRS)
Schryer, David R.; Sidney, Barry D.; Miller, Irvin M.; Hess, Robert V.; Wood, George M.; Batten, Carmen E.; Burney, Lewis G.; Hoyt, Ronald F.; Paulin, Patricia A.; Brown, Kenneth G.
1987-01-01
Long-life, closed-cycle operation of pulsed CO2 lasers requires catalytic CO-O2 recombination both to remove O2, which is formed by discharge-induced CO2 decomposition, and to regenerate CO2. Platinum metal on a tin (IV) oxide substrate (Pt/SnO2) has been found to be an effective catalyst for such recombination in the desired temperature range of 25 to 100 C. This paper presents a description of ongoing research at NASA-LaRC on Pt/SnO2 catalyzed CO-O2 recombination. Included are studies with rare-isotope gases since rare-isotope CO2 is desirable as a laser gas for enhanced atmospheric transmission. Results presented include: (1) achievement of 98% to 100% conversion of a stoichiometric mixture of CO and O2 to CO2 for 318 hours (greater than 1 x 10 to the 6th power seconds), continuous, at a catalyst temperature of 60 C, and (2) development of a technique verified in a 30-hour test, to prevent isotopic scrambling when CO-18 and O-18(2) are reacted in the presence of a common-isotope Pt/Sn O-16(2) catalyst.
CO2 laser-driven Stirling engine. [space power applications
NASA Technical Reports Server (NTRS)
Lee, G.; Perry, R. L.; Carney, B.
1978-01-01
A 100-W Beale free-piston Stirling engine was powered remotely by a CO2 laser for long periods of time. The engine ran on both continuous-wave and pulse laser input. The working fluid was helium doped with small quantities of sulfur hexafluoride, SF6. The CO2 radiation was absorbed by the vibrational modes of the sulfur hexafluoride, which in turn transferred the energy to the helium to drive the engine. Electrical energy was obtained from a linear alternator attached to the piston of the engine. Engine pressures, volumes, and temperatures were measured to determine engine performance. It was found that the pulse radiation mode was more efficient than the continuous-wave mode. An analysis of the engine heat consumption indicated that heat losses around the cylinder and the window used to transmit the beam into the engine accounted for nearly half the energy input. The overall efficiency, that is, electrical output to laser input, was approximately 0.75%. However, this experiment was not designed for high efficiency but only to demonstrate the concept of a laser-driven engine. Based on this experiment, the engine could be modified to achieve efficiencies of perhaps 25-30%.
Laser materials processing facility
NASA Technical Reports Server (NTRS)
Haggerty, J. S.
1982-01-01
The laser materials processing facility and its capabilities are described. A CO2 laser with continuous wave, repetitive pulse, and shaped power-time cycles is employed. The laser heated crystal growth station was used to produce metal and metal oxide single crystals and for cutting and shaping experiments using Si3N4 to displace diamond shaping processes.
Application of a flexible CO(2) laser fiber for neurosurgery: laser-tissue interactions.
Ryan, Robert W; Wolf, Tamir; Spetzler, Robert F; Coons, Stephen W; Fink, Yoel; Preul, Mark C
2010-02-01
The CO(2) laser has an excellent profile for use in neurosurgery. Its high absorption in water results in low thermal spread, sparing adjacent tissue. Use of this laser has been limited to line-of-sight applications because no solid fiber optic cables could transmit its wavelength. Flexible photonic bandgap fiber technology enables delivery of CO(2) laser energy through a flexible fiber easily manipulated in a handheld device. The authors examined and compared the first use of this CO(2) laser fiber to conventional methods for incising neural tissue. Carbon dioxide laser energy was delivered in pulsed or continuous wave settings for different power settings, exposure times, and distances to cortical tissue of 6 anesthetized swine. Effects of CO(2) energy on the tissue were compared with bipolar cautery using a standard pial incision technique, and with scalpel incisions without cautery. Tissue was processed for histological analysis (using H & E, silver staining, and glial fibrillary acidic protein immunohistochemistry) and scanning electron microscopy, and lesion measurements were made. Light microscopy and scanning electron microscopy revealed laser incisions of consistent shape, with central craters surrounded by limited zones of desiccated and edematous tissue. Increased laser power resulted in deeper but not significantly wider incisions. Bipolar cautery lesions showed desiccated and edematous zones but did not incise the pia, and width increased more than depth with higher power. Incisions made without using cautery produced hemorrhage but minimal adjacent tissue damage. The photonic bandgap fiber CO(2) laser produced reliable cortical incisions, adjustable over a range of settings, with minimal adjacent thermal tissue damage. Ease of application under the microscope suggests this laser system has reached true practicality for neurosurgery.
The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies.
El Gamal, Ahmed; Fornaini, Carlo; Rocca, Jean Paul; Muhammad, Omid H; Medioni, Etienne; Cucinotta, Annamaria; Brulat-Bouchard, Nathalie
2016-03-31
The objective of this study was to investigate the interaction of infrared laser light on Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) ceramic surfaces. Sixty CAD/CAM ceramic discs were prepared and divided into two different groups: lithiumdisilicate ceramic (IPSe.maxCADs) and Zirconia ceramic (IPSe.maxZirCADs). The laser irradiation was performed on graphite and non-graphite surfaces with a Carbon Dioxide laser at 5W and 10W power in continuous mode (CW mode) and with Neodymium Yttrium Aluminum Perovskite (Nd:YAP) laser at 10W. Surface textures and compositions were examined using Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). Thermal elevation was measured by thermocouple during laser irradiation. The SEM observation showed a rough surface plus cracks and fissures on CO2 10W samples and melting areas in Nd:YAP samples; moreover, with CO2 5W smooth and shallow surfaces were observed. EDS analysis revealed that laser irradiation does not result in modifications of the chemical composition even if minor changes in the atomic mass percentage of the components were registered. Thermocouple showed several thermal changes during laser irradiation. CO2 and Nd:YAP lasers modify CAD/CAM ceramic surface without chemical composition modifications.
Catalyst for Carbon Monoxide Oxidation
NASA Technical Reports Server (NTRS)
Davis, Patricia; Brown, Kenneth; VanNorman, John; Brown, David; Upchurch, Billy; Schryer, David; Miller, Irvin
2010-01-01
In many applications, it is highly desirable to operate a CO2 laser in a sealed condition, for in an open system the laser requires a continuous flow of laser gas to remove the dissociation products that occur in the discharge zone of the laser, in order to maintain a stable power output. This adds to the operating cost of the laser, and in airborne or space applications, it also adds to the weight penalty of the laser. In a sealed CO2 laser, a small amount of CO2 gas is decomposed in the electrical discharge zone into corresponding quantities of CO and O2. As the laser continues to operate, the concentration of CO2 decreases, while the concentrations of CO and O2 correspondingly increase. The increasing concentration of O2 reduces laser power, because O2 scavenges electrons in the electrical discharge, thereby causing arcing in the electric discharge and a loss of the energetic electrons required to boost CO2 molecules to lasing energy levels. As a result, laser power decreases rapidly. The primary object of this invention is to provide a catalyst that, by composition of matter alone, contains chemisorbed water within and upon its structure. Such bound moisture renders the catalyst highly active and very long-lived, such that only a small quantity of it needs to be used with a CO2 laser under ambient operating conditions. This object is achieved by a catalyst that consists essentially of about 1 to 40 percent by weight of one or more platinum group metals (Pt, Pd, Rh, Ir, Ru, Os, Pt being preferred); about 1 to 90 percent by weight of one or more oxides of reducible metals having multiple valence states (such as Sn, Ti, Mn, Cu, and Ce, with SnO2 being preferred); and about 1 to 90 percent by weight of a compound that can bind water to its structure (such as silica gel, calcium chloride, magnesium sulfate, hydrated alumina, and magnesium perchlorate, with silica gel being preferred). Especially beneficial results are obtained when platinum is present in the catalyst composition in an amount of about 5 to 25 (especially 7) percent by weight, SnO2 is present in an amount of about 30 to 40 (especially 40) percent by weight, and silica gel is present in an amount of 45 to 55 (especially 50) percent by weight. The composition of this catalyst was suggested by preliminary experiments in which a Pt/SnO2 catalyst was needed for bound water to enhance its activity. These experimental results suggested that if the water were bound to the surface, this water would enhance and prolong catalyst activity for long time periods. Because the catalyst is to be exposed to a laser gas mixture, and because a CO2 laser can tolerate only a very small amount of moisture, a hygroscopic support for the catalyst would provide the needed H2O into the gas. Silica gel is considered to be superior because of its property to chemisorb water on its surface over a wide range of moisture content.
Tan, Jun; Lei, Ying; Ouyang, Hua-Wei; Gold, Michael H
2014-12-01
The purpose of this clinical paper is to explore the therapeutic effects, healing times, adverse effects, and maintenance periods of using a CO2 fractional laser in the treatment of photoaging in Asian skin. One fractional CO2 laser procedure was performed on the full face in 56 patients with photoaging. Based on the Dover scoring system, we evaluated the degree of skin aging before treatment and at one-month post laser and at five years post laser therapy in 30 of the patients. Statistical analysis was performed by the Wilcoxon's method. Thirty of the treated patients have had follow-up for 5 years at this time. The photoaging scores in these thirty patients were significantly changed (P < 0.01) at one month, one year, and five years after the fractional laser treatment, as compared with their baseline. Adverse events seen during this analysis were found to be minimal and not of clinical significance. Fractional CO2 laser resurfacing in the treatment of photoaging in Asians is a useful modality with results, for the first time, being shown to have continued efficacy for up to 5 years. © 2014 Wiley Periodicals, Inc.
Visible light plasmonic heating of Au-ZnO for the catalytic reduction of CO 2
Wang, Congjun; Ranasingha, Oshadha; Natesakhawat, Sittichai; ...
2013-01-01
Plasmonic excitation of Au nanoparticles attached to the surface of ZnO catalysts using low power 532 nm laser illumination leads to significant heating of the catalyst and the conversion of CO 2 and H 2 reactants to CH 4 and CO products. Temperature-calibrated Raman spectra of ZnO phonons show that intensity-dependent plasmonic excitation can controllably heat Au–ZnO from 30 to ~600 °C and simultaneously tune the CH 4 : CO product ratio. The laser induced heating and resulting CH 4 : CO product distribution agrees well with predictions from thermodynamic models and temperature-programmed reaction experiments indicating that the reaction ismore » a thermally driven process resulting from the plasmonic heating of the Au-ZnO. The apparent quantum yield for CO 2 conversion under continuous wave (cw) 532 nm laser illumination is 0.030%. The Au-ZnO catalysts are robust and remain active after repeated laser exposure and cycling. The light intensity required to initiate CO 2 reduction is low ( ~2.5 x 10 5 W m -2) and achievable with solar concentrators. Our results illustrate the viability of plasmonic heating approaches for CO 2 utilization and other practical thermal catalytic applications.« less
Nd:YAG and CO2 laser therapy of oral mucosal lesions.
White, J M; Chaudhry, S I; Kudler, J J; Sekandari, N; Schoelch, M L; Silverman, S
1998-12-01
Experiences gained in the management of oral mucosal lesions by CO2 and Nd:YAG laser therapy in an outpatient clinic treated over an 80-year period are described. Lasers have indications for use in dentistry for incision, excision, and coagulation of intraoral soft tissue. Advances in laser technology have provided delivery systems for site-specific delivery of laser energy with short interaction items on tissue to be ablated. This study retrospectively evaluates a series of clinical case studies. Sixty-four patients with a variety of benign oral soft tissue lesions were treated by laser excision. Thirty-five patients were treated by a pulsed fiberoptic delivered Nd:YAG contact laser, and 29 by a continuous free-beam CO2 non-contact laser. The largest group of lesions treated were leukoplakia (39 cases). Other lesions excised and biopsied were lichen planus, squamous papilloma, pyogenic granuloma, focal melanosis, nonhealing traumatic ulceration, hemangioma, and lymphangioma. All patients were followed postoperatively (mean 6.8 months, range 1-36 months). Laser excision was well tolerated by patients with no intraoperative or postoperative adverse effects. All patients healed postsurgically with no loss of function. CO2 and Nd:YAG lasers are successful surgical options when performing excision of benign intraoral lesions. Advantages of laser therapy include minimal postoperative pain, conservative site-specific minimally invasive surgeries, and elimination of need for sutures.
Control system of an excitation power supply for fast axial flow CO2 lasersupda
NASA Astrophysics Data System (ADS)
Li, Bo; Jia, Xinting; Yuan, Hao; Gao, Yuhu; Wang, Youqing
2009-08-01
A switching power control system of fast axial flow CO2 lasers based on DSP is presented. The key techniques are described in detail, include the control principle, realization method and program design. The experiment showed that the system make the laser discharge stably and work in multi-mode. The discharge current can be adjusted from 3mA to 85mA continuously. 20-2000Hz frequency, 0-100% duty cycle laser pulse is achieved. The power supply can improve the processing efficiency and quality.
Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space
NASA Technical Reports Server (NTRS)
Abshire, James B.; Riris, Haris; Kawa, S. Randy; Sun, Xiaoli; Chen, Jeffrey; Stephen, Mark A.; Collatz, G. James; Mao, Jianping; Allan, Graham
2007-01-01
Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.
Tosun, Emre; Tasar, Ferda; Strauss, Robert; Kıvanc, Dolunay Gulmez; Ungor, Cem
2012-05-01
This study examined carbon dioxide (CO(2); 10,600 nm), diode (808 nm), and erbium (Er):yttrium-aluminum-garnet (YAG; 2,940 nm) laser applications on Staphylococcus aureus contaminated, sandblasted, large-grit, acid-etched surface titanium discs and performed a comparative evaluation of the obtained bactericidal effects and the applicability of these effects in clinical practice. This study was carried out in 5 main groups: Er:YAG laser in very short pulse (VSP) emission mode, Er:YAG laser in short pulse (SP) emission mode, diode laser with a 320-nm fiber optic diode laser with an R24-B handpiece, and CO(2) laser. After laser irradiation, dilutions were spread on sheep blood agar plates and, after an incubation period of 24 hours, colony-forming units were counted and compared with the control group, and the bactericidal activity was assessed in relation to the colony counts. The CO(2) laser eliminated 100% of the bacteria at 6 W, 20 Hz, and a 10-ms exposure time/pulse with a 10-second application period (0.8-mm spot size). The continuous-wave diode laser eliminated 97% of the bacteria at 1 W using a 10-second application with a 320-μm optic fiber, 100% of the bacteria were killed with a 1-W, 10-second continuous-wave application with an R14-B handpiece. The Er:YAG laser eliminated 100% of the bacteria at 90 mJ and 10 Hz using a 10-second application in a superpulse mode (300-ms exposure time/pulse). The Er:YAG laser also eliminated 99% to 100% of the bacteria in VSP mode at 90 mJ and 10 Hz with a 10-second application. The results of this study show that a complete, or near complete, elimination of surface bacteria on titanium surfaces can be accomplished in vitro using a CO(2), diode, or Er:YAG laser as long as appropriate parameters are used. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. All rights reserved.
Truschnegg, Astrid; Acham, Stephan; Kqiku, Lumnije; Beham, Alfred; Jakse, Norbert
2016-09-01
This article reports the CO2 laser excision of a pyogenic granuloma related to dental implants and reviews the current literature on this pathology in association with dental implants. Five publications describe pyogenic granulomas related to dental implants, and a further one describes the removal of such a lesion with an Er:YAG laser; removal with a CO2 laser is not reported. A 67-year-old male patient presented with a hyperplastic gingival lesion around two implants in the left lower jaw. The hyperplastic tissue was removed with a CO2 laser (Lasram; model OPAL 25, 25 W continuous wave, 10.600 nm, gas laser), and a vestibuloplasty was performed. The excised tissue was examined histopathologically. The patient was followed up after 4 weeks, 6 weeks, 6 months, and 1 year, and a panoramic X-ray was also made. There were no complications during surgery or follow-up. The panoramic X-ray taken 1 year after excision showed neither vertical bone loss nor impaired osseointegration of the implant. Histopathology reported a pyogenic granuloma. After vestibuloplasty, the height of the fixed mucosa was satisfactory. The CO2 laser seems to be a safe and appropriate tool for removal of a pyogenic granuloma in close proximity to dental implants. The laser parameters must, however, be chosen carefully and any additional irritants should be excluded to prevent a recurrence.
NASA Technical Reports Server (NTRS)
Dobler, Jeremy T.; Harrison, F. Wallace; Browell, Edward V.; Lin, Bing; McGregor, Doug; Kooi, Susan; Choi, Yonghoon; Ismail, Syed
2013-01-01
The 2007 National Research Council (NRC) Decadal Survey on Earth Science and Applications from Space recommended Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as a mid-term, Tier II, NASA space mission. ITT Exelis, formerly ITT Corp., and NASA Langley Research Center have been working together since 2004 to develop and demonstrate a prototype Laser Absorption Spectrometer for making high-precision, column CO2 mixing ratio measurements needed for the ASCENDS mission. This instrument, called the Multifunctional Fiber Laser Lidar (MFLL), operates in an intensity-modulated, continuous-wave mode in the 1.57- micron CO2 absorption band. Flight experiments have been conducted with the MFLL on a Lear-25, UC-12, and DC-8 aircraft over a variety of different surfaces and under a wide range of atmospheric conditions. Very high-precision CO2 column measurements resulting from high signal-to-noise (great than 1300) column optical depth measurements for a 10-s (approximately 1 km) averaging interval have been achieved. In situ measurements of atmospheric CO2 profiles were used to derive the expected CO2 column values, and when compared to the MFLL measurements over desert and vegetated surfaces, the MFLL measurements were found to agree with the in situ-derived CO2 columns to within an average of 0.17% or approximately 0.65 ppmv with a standard deviation of 0.44% or approximately 1.7 ppmv. Initial results demonstrating ranging capability using a swept modulation technique are also presented.
The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies
Fornaini, Carlo; Rocca, Jean Paul; Muhammad, Omid H; Medioni, Etienne; Cucinotta, Annamaria; Brulat-Bouchard, Nathalie
2016-01-01
Background and aims: The objective of this study was to investigate the interaction of infrared laser light on Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) ceramic surfaces. Material and Methods: Sixty CAD/CAM ceramic discs were prepared and divided into two different groups: lithiumdisilicate ceramic (IPSe.maxCADs) and Zirconia ceramic (IPSe.maxZirCADs). The laser irradiation was performed on graphite and non-graphite surfaces with a Carbon Dioxide laser at 5W and 10W power in continuous mode (CW mode) and with Neodymium Yttrium Aluminum Perovskite (Nd:YAP) laser at 10W. Surface textures and compositions were examined using Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). Thermal elevation was measured by thermocouple during laser irradiation. Results: The SEM observation showed a rough surface plus cracks and fissures on CO2 10W samples and melting areas in Nd:YAP samples; moreover, with CO2 5W smooth and shallow surfaces were observed. EDS analysis revealed that laser irradiation does not result in modifications of the chemical composition even if minor changes in the atomic mass percentage of the components were registered. Thermocouple showed several thermal changes during laser irradiation. Conclusion: CO2 and Nd:YAP lasers modify CAD/CAM ceramic surface without chemical composition modifications. PMID:27141152
Karaman, Murat; Gün, Taylan; Temelkuran, Burak; Aynacı, Engin; Kaya, Cem; Tekin, Ahmet Mahmut
2017-05-01
To compare intra-operative and post-operative effectiveness of fiber delivered CO 2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO 2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO 2 laser. The use of CO 2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO 2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO 2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.
Thermal affected zone obtained in machining steel XC42 by high-power continuous CO 2 laser
NASA Astrophysics Data System (ADS)
Jebbari, Neila; Jebari, Mohamed Mondher; Saadallah, Faycal; Tarrats-Saugnac, Annie; Bennaceur, Raouf; Longuemard, Jean Paul
2008-09-01
A high-power continuous CO 2 laser (4 kW) can provide energy capable of causing melting or even, with a special treatment of the surface, vaporization of an XC42-steel sample. The laser-metal interaction causes an energetic machining mechanism, which takes place according to the assumption that the melting front precedes the laser beam, such that the laser beam interacts with a preheated surface whose temperature is near the melting point. The proposed model, obtained from the energy balance during the interaction time, concerns the case of machining with an inert gas jet and permits the calculation of the characteristic parameters of the groove according to the characteristic laser parameters (absorbed laser energy and impact diameter of the laser beam) and allows the estimation of the quantity of the energy causing the thermal affected zone (TAZ). This energy is equivalent to the heat quantity that must be injected in the heat propagation equation. In the case of a semi-infinite medium with fusion temperature at the surface, the resolution of the heat propagation equation gives access to the width of the TAZ.
Pulsed 2-micron Laser Transmitter For Carbon Dioxide Sensing From Space
NASA Astrophysics Data System (ADS)
Singh, U. N.; Yu, J.; Bai, Y.; Petros, M.
2011-12-01
Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. Studies of the carbon cycle are limited by the tools available to precisely measure CO2 concentrations by remote sensing. Active sensing, using the Integrated Path Differential Absorption (IPDA) approach, permits measurements day and night, at all latitudes and seasons. The development of a high pulse energy 2-μm laser transmitter for high-precision CO2 measurements from space leverages years of NASA investment in solid-state laser technology. Under NASA Laser Risk Reduction Program, funded by Earth Science Technology Office, researchers at NASA Langley Research Center developed an injection seeded, high repetition rate, Q-switched Ho:YLF laser transmitter for CO2 Differential Absorption Lidar/IPDA (profile/column) measurements from ground and airborne platforms. This master-slave laser system has high optical-to-optical efficiency and seeding success rate. NASA LaRC's 2-micron pulsed laser transmitter possesses advantages over current passive and CW active sensors. First, the pulsed format provides a built-in means for determining range to the scattering target and effectively filtering out the scattering from thin clouds and aerosols, thus eliminating a source of measurement bias. Second, by concentrating the laser energy into a pulse, sufficient backscatter signal strength can be obtained from aerosol scattering rather than relying on a hard target at a known distance. Third, the absorption line at the 2.05 μm band is ideally suited for the CO2 concentration measurement. In particular, the weighting function of 2 μm is optimum for measurement in the lower troposphere where the sources and sinks of CO2 are located. The planned laser transmitter development will lead to a Tm:Fiber pumped Ho:YLF laser transmitter capable of delivering 65 mJ at 50 Hz at on-line wavelength and 50 mJ at 50 Hz at off-line wavelength. The planned laser technology development and performance capabilities are a major step forward in the laser transmitter requirements called out in recent comprehensive system studies, e.g., the European Space Agency (ESA) exploration mission studies, A-SCOPE, for future CO2 column density measurements from space. The planned laser technology development is relevant to NASA's earth science priorities, such as NASA ASCENDS mission for space-based CO2 column density measurements. This presentation will provide an overview of the current status of laser transmitter development and describe future technology development to meet the transmitter requirement for a space-based column averaged measurement of CO2 concentration.
Development of an automated diode-laser-based multicomponent gas sensor
NASA Technical Reports Server (NTRS)
Richter, D.; Lancaster, D. G.; Tittel, F. K.
2000-01-01
The implementation and application of a portable fiber-coupled trace-gas sensor for the detection of several trace gases, including CO2, CH4, and H2CO, are reported. This particular sensor is based on a cw fiber-amplified near-infrared (distributed Bragg reflector) diode laser and an external cavity diode laser that are frequency converted in a periodically poled lithium niobate crystal to the mid-IR spectroscopic fingerprint region (3.3-4.4 micrometers). A continuous absorption spectrum of CH4 and H2CO from 3.37 to 3.10 micrometers with a spectral resolution of 40 MHz (approximately 0.0013 cm-1) demonstrated the spectral performance that can be achieved by means of automated wavelength tuning and phase matching with stepper motor control. Autonomous long-term detection of ambient CO2 and CH4 over a 3- and 7-day period was also demonstrated.
Fluid mechanics of fusion lasers. Final report, September 11, 1978-June 5, 1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shwartz, J; Kulkarny, V A; Ausherman, D A
1980-01-01
Flow loop components required to operate continuous-flow, repetitively-pulsed CO/sub 2/ and KrF laser drivers for ICF were identified and their performance requirements were specified. It was found that the laser flow loops can have a major effect on the laser beam quality and overall efficiency. The pressure wave suppressor was identified as the most critical flow loop component. The performance of vented side-wall suppressors was evaluated both analytically and experimentally and found capable of meeting the performance requirements of the CO/sub 2/ and KrF fusion lasers. All other laser flow loop components are essentially similar to those used in conventional,more » low speed wind tunnels and are therefore well characterized and can be readily incorporated into fusion laser flow systems designs.« less
Atmospheric remote sensing of water vapor, HCl and CH4 using a continuously tunable Co:MgF2 laser
NASA Technical Reports Server (NTRS)
Menyuk, Norman; Killinger, Dennis K.
1987-01-01
A differential-absorption lidar system has been developed which uses a continuously tunable (1.5-2.3 micron) cobalt-doped magnesium fluoride laser as the radiation source. Preliminary atmospheric measurements of water vapor, HCl, and CH4 have been made with this system, including both path-averaged and ranged-resolved DIAL measurements at ranges up to 6 and 3 km, respectively.
Recent advances in CO2 laser catalysts
NASA Technical Reports Server (NTRS)
Upchurch, B. T.; Schryer, D. R.; Brown, K. G.; Kielin, E. J.; Hoflund, G. B.; Gardner, S. D.
1991-01-01
This paper discusses several recent advances in CO2 laser catalysts including comparisons of the activity of Au/MnO2 to Pt/SnO2 catalysts with possible explanations for observed differences. The catalysts are compared for the effect of test gas composition, pretreatment temperature, isotopic integrity, long term activity, and gold loading effects on the Au/MnO2 catalyst activity. Tests conducted to date include both long-term tests of up to six months continuous operation and short-term tests of one week or more that include isotopic integrity testing.
De Rosa, Maurizio; Gagliardi, Gianluca; Rocco, Alessandra; Somma, Renato; De Natale, Paolo; De Natale, Giuseppe
2007-04-20
We report on a continuous-measurement campaign carried out in Vulcano (Aeolian islands, Sicily), devoted to the simultaneous monitoring of CO2 and H2O concentrations. The measurements were performed with an absorption spectrometer based on a semiconductor laser source emitting around a 2-microm wavelength. The emitted radiation was selectively absorbed by two molecular ro-vibrational transitions specific of the investigated species. Data for CO2 and H2O concentrations, and CO2 soil diffusive flux using an accumulation chamber configuration, were collected at several interesting sampling points on the island (Porto Levante beach- PLB, Fossa Grande Crater - FOG- and Valley of Palizzi, PAL). CO2/H2O values, measured on the ground, are very similar (around 0.019 (+/- 0.006)) and comparable to the previous discrete detected values of 0.213 (Fumarole F5-La Fossa crater rim) and 0.012 (Fumarole VFS - Baia Levante beach) obtaid during the 1977-1993 heating phase of the crater fumaroles. In this work much more homogeneous values are found in different points of the three sites investigated. The field work, although carried out in a limited time window (25th-28th August 2004), pointed out the new apparatus is suitable for continuous gas monitoring of the two species and their ratios, which are important geochemical indicators of volcanic activity, for which other reliable continuous monitoring systems are not yet available.
Microhardness evaluations of CAD/CAM ceramics irradiated with CO2 or Nd:YAP laser
Rocca, Jean Paul; Fornaini, Carlo; Medioni, Etienne; Brulat-Bouchard, Nathalie
2017-01-01
Background and aims The aim of this study was to measure the microhardness values of irradiated computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics surfaces before and after thermal treatment. Materials and Methods Sixty CAD/CAM ceramic discs were prepared and grouped by material, i.e. lithium disilicate ceramic (Emax CAD) and zirconia ceramic (Emax ZirCAD). Laser irradiation at the material surface was performed with a carbon dioxide laser at 5 Watt (W) or 10 W power in continuous mode (CW mode), or with a neodymium:yttrium aluminum perovskite (Nd:YAP) laser at 10 W on graphite and non-graphite surfaces. Vickers hardness was tested at 0.3 kgf for lithium disilicate and 1 kgf for zirconia. Results Emax CAD irradiated with CO2 at 5 W increased microhardness by 6.32 GPa whereas Emax ZirCAD irradiated with Nd:YAP decreased microhardness by 17.46 GPa. Conclusion CO2 laser effectively increases the microhardness of lithium disilicate ceramics (Emax CAD). PMID:28740324
Lin, C P; Tseng, Y C; Lin, F H; Liao, J D; Lan, W H
2001-03-01
Acute trauma or trauma associated with occlusal disturbance can produce tooth crack or fracture. Although several methods are proposed to treat the defect, however, the prognosis is generally poor. If the fusion of a tooth fracture by laser is possible, it will offer an alternative to extraction or at least serve as an adjunctive treatment in the reconstruction. We have tried to use a continuous-wave CO2 laser and a newly developed DP-bioactive glass paste (DPGP) to fuse or bridge tooth crack or fracture lines. Both the DP-bioactive glass paste and tooth enamel have strong absorption bands at the wavelength of 10.6 microm. Therefore, under CO2 laser, DPGP and enamel should have an effective absorption and melt together. The interface between DPGP and enamel could be regarded as a mixture of DPGP and enamel (DPG-E). The study focused on the phase transformation, microstructure, functional group and thermal behavior of DPG-E with or without CO2 laser irradiation, by the analytical techniques of XRD, FTIR, DTA/TGA, and SEM. The results of XRD showed that the main crystal phase in the DPG-E was dicalcium phosphate dihydrate (CaHPO4.2H2O). It changed into CaHPO4, gamma-Ca2P2O7, beta-Ca2P2O7 and finally alpha-Ca2P2O7 with increasing temperature. In the FTIR analysis, the 720 cm(-1) absorption band ascribed to the P-O-P linkage in pyrophosphate rose up and the intensities of the OH- bands reduced after laser irradiation. In regard to the results of DTA/TGA after irradiation, the weight loss decreased due to the removal of part of absorption water and crystallization water by the CO2 laser. SEM micrographs revealed that the melted masses and the plate-like crystals formed a tight chemical bond between the enamel and DPGP. We expect that DPGP with the help of CO2 laser can be an alternative to the treatment of tooth crack or fracture.
NASA Astrophysics Data System (ADS)
van Geldern, Robert; Nowak, Martin; Zimmer, Martin; Szizybalski, Alexandra; Myrttinen, Anssi; Barth, Johannes A. C.; Jost, Hj
2016-04-01
A newly developed and commercially available isotope ratio laser spectrometer for CO2 analyses has been tested during a 10-day field monitoring campaign at the Ketzin pilot site for CO2 storage in northern Germany. The laser instrument is based on tunable laser direct absorption in the mid-infrared. The instrument recorded a continuous 10-day carbon stable isotope data set with 30 minutes resolution directly on-site in a field-based laboratory container during a tracer experiment. To test the instruments performance and accuracy the monitoring campaign was accompanied by daily CO2 sampling for laboratory analyses with isotope ratio mass spectrometry (IRMS). The carbon stable isotope ratios measured by conventional IRMS technique and by the new mid-infrared laser spectrometer agree remarkably well within 2σ analytical precision (<0.3 ‰). This proves the capability of the new mid-infrared direct absorption technique to measure high precision and accurate real-time table isotope data directly in the field. The injected CO2 tracer had a distinct δ13C value that was largely different from the reservoir background value. The laser spectroscopy data revealed a prior to this study unknown, intensive dynamic with fast changing δ13C values. The arrival pattern of the tracer suggest that the observed fluctuations were probably caused by migration along separate and distinct preferential flow paths between injection well and observation well. The new technique might contribute to a better tracing of the migration of the underground CO2 plume and help to ensure the long-term integrity of the reservoir.
The use of laser CO2 in salivary gland diseases
NASA Astrophysics Data System (ADS)
Ciolfi, C.; Rocchetti, F.; Fioravanti, M.; Tenore, G.; Palaia, G.; Romeo, U.
2016-03-01
Salivary gland diseases can include reactive lesions, obstructive lesions, and benign tumors. All these clinical entities are slow growing. Salivary glands reactive lesions, such as mucoceles, can result from extravasation of saliva into the surrounding soft tissue or from retention of saliva within the duct. Sialolithiasis, one of the most common obstructive lesions, is generally due to calculi, which are attributed to retention of saliva. Monomorphic adenoma is a salivary gland benign tumor, which is exclusively resulted from proliferation of epithelial cells, with no alterations interesting the connective tissue. The elective therapy of these lesions is surgical excision because sometimes they can be accompained by difficulties during chewing and phonation and can interfere with prosthesis's stability. The aim of the study is to evaluate the efficacy of CO2 laser in the treatment of patients with salivary gland diseases. Three different cases - a mucocele, a scialolithiasis and a monomorphic adenoma - were treated with CO2 laser excision (CW and 4W), under local anesthesia. Two different techniques were used: circumferential incision for the adenoma, and mucosa preservation technique for mucocele and sialolithiasis. In each case final haemostasis was obtained by thermocoagulation, but suture was applied to guarantee good healing by sewing up the flaps. The patients were checked after twenty days and the healing was good. The carbon dioxide laser (CO2 laser) was one of the earliest gas laser to be developed, and is still the highest-power continuous wave laser that is currently available. In dentistry the CO2 laser produces a beam of infrared light with the principal wavelength bands centering around 9.4 and 10.6 micrometers. Laser excision can be very useful in oral surgery. In the cases presented CO2 laser offered, differently from traditional surgery, simplified surgical technique, shorter duration of operation, minimal postoperative pain, minimal scarring, bloodless field and the possibility to realize minimally invasive surgery. These advantages made the operation tolerable for the patients, that became more compliant. Optimum functional results can be expected.
Le Laser A Argon Ionise : Applications Therapeutiques
NASA Astrophysics Data System (ADS)
Brunetaud, J. M.; Mosquet, L.; Mordon, S.; Rotteleur, G.
1984-03-01
Le laser a argon ionise est un laser a emission continue, reglee en general en multiraies de 487 a 544 nm. Le rayonnement de ce laser est bien absorbe par les tissus vivants, avec une action preferentielle au niveau des pigments rouges (hemoglobine, myoglobine) et noirs (melanine). Le laser a argon est princi-palement utilise en therapeutique pour ses effets thermiques : en fonction du choix des parametres (puissance optique, surface exposee, temps d'exposition) on peut obtenir une coagulation (temperature optimale au niveau des tissus 60° - 80°) ou une volatisation (temperature superieure a 100°). Si la zone volatilisee est tres etroite (inferieure a 0,5 mm) on obtient un effet de coupe. Par rapport aux deux autres lasers egalement utilises pour leurs effets thermiques (CO2 et Nd. YAG) l'argon a des effets intermediaires : la coagulation sera plus superficielle qu'avec le Nd. YAG et la volatisation plus profonde qu'avec le CO2. Lors de la coupe, la necrose sur les berges sera egalement plus importante qu'avec le CO2.
NASA Astrophysics Data System (ADS)
Acosta, Roberto I.
The high-energy laser (HEL) lethality community needs for enhanced laser weapons systems requires a better understanding of a wide variety of emerging threats. In order to reduce the dimensionality of laser-materials interaction it is necessary to develop novel predictive capabilities of these events. The objective is to better understand the fundamentals of laser lethality testing by developing empirical models from hyperspectral imagery, enabling a robust library of experiments for vulnerability assessments. Emissive plumes from laser irradiated fiberglass reinforced polymers (FRP), poly(methyl methacrylate) (PMMA) and porous graphite targets were investigated primarily using a mid-wave infrared (MWIR) imaging Fourier transform spectrometer (FTS). Polymer and graphite targets were irradiated with a continuous wave (cw) fiber lasers. Data was acquired with a spectral resolution of 2 cm-1 and spatial resolution as high as 0.52 mm2 per pixel. Strong emission from H2O, CO, CO2 and hydrocarbons were observed in the MWIR between 1900-4000 cm-1. A single-layer radiative transfer model was developed to estimate spatial maps of temperature and column densities of CO and CO2 from the hyperspectral imagery of the boundary layer plume. The spectral model was used to compute the absorption cross sections of CO and CO2, using spectral line parameters from the high temperature extension of the HITRAN. Also, spatial maps of gas-phase temperature and methyl methacrylate (MMA) concentration were developed from laser irradiated carbon black-pigmented PMMA at irradiances of 4-22 W/cm2. Global kinetics interplay between heterogeneous and homogeneous combustion kinetics are shown from experimental observations at high spatial resolutions. Overall the boundary layer profile at steady-state is consistent with CO being mainly produced at the surface by heterogeneous reactions followed by a rapid homogeneous combustion in the boundary layer towards buoyancy.
NASA Technical Reports Server (NTRS)
Briggs, Ryan M.; Frez, Clifford; Borgentun, Carl E.; Bagheri, Mahmood; Forouhar, Siamak; May, Randy D.
2014-01-01
Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.
Reactivation of a Tin-Oxide-Containing Catalyst
NASA Technical Reports Server (NTRS)
Hess, Robert; Sidney, Barry; Schryer, David; Miller, Irvin; Miller, George; Upchurch, Bill; Davis, Patricia; Brown, Kenneth
2010-01-01
The electrons in electric-discharge CO2 lasers cause dissociation of some CO2 into O2 and CO, and attach themselves to electronegative molecules such as O2, forming negative O2 ions, as well as larger negative ion clusters by collisions with CO or other molecules. The decrease in CO2 concentration due to dissociation into CO and O2 will reduce the average repetitively pulsed or continuous wave laser power, even if no disruptive negative ion instabilities occur. Accordingly, it is the primary object of this invention to extend the lifetime of a catalyst used to combine the CO and O2 products formed in a laser discharge. A promising low-temperature catalyst for combining CO and O2 is platinum on tin oxide (Pt/SnO2). First, the catalyst is pretreated by a standard procedure. The pretreatment is considered complete when no measurable quantity of CO2 is given off by the catalyst. After this standard pretreatment, the catalyst is ready for its low-temperature use in the sealed, high-energy, pulsed CO2 laser. However, after about 3,000 minutes of operation, the activity of the catalyst begins to slowly diminish. When the catalyst experiences diminished activity during exposure to the circulating gas stream inside or external to the laser, the heated zone surrounding the catalyst is raised to a temperature between 100 and 400 C. A temperature of 225 C was experimentally found to provide an adequate temperature for reactivation. During this period, the catalyst is still exposed to the circulating gas inside or external to the laser. This constant heating and exposing the catalyst to the laser gas mixture is maintained for an hour. After heating and exposing for an appropriate amount of time, the heated zone around the catalyst is allowed to return to the nominal operating temperature of the CO2 laser. This temperature normally resides in the range of 23 to 100 C. Catalyst activity can be measured as the percentage conversion of CO to CO2. In the specific embodiment described above, the initial steady-state conversion percentage was 70 percent. After four days, this conversion percentage decreased to 67 percent. No decrease in activity is acceptable because the catalyst must maintain its activity for long periods of time. After being subjected to the reactivation process of the present invention, the conversion percentage rose to 77 percent. Such a reactivation not only returned the catalyst to its initial steady state but resulted in a 10-percent improvement over the initial steady state value.
NASA Astrophysics Data System (ADS)
Bailey, D. M.; Miller, J. H. H.
2017-12-01
Beyond anthropogenic carbon emissions, the increase in atmospheric carbon from natural feedbacks such as thawing permafrost poses a risk to the global climate as global temperatures continue to increase. Permafrost is formally defined as soil that is continuously frozen for 24 consecutive months. These soils comprise nearly twenty-five percent of the Earth's terrestrial surface and possess twice the amount of carbon currently in the atmosphere. Continuous collection of carbon dioxide (CO2) and methane (CH4) concentrations is imperative in understanding seasonal and inter-annual variability of carbon feedbacks above thawing permafrost. A multi-year collaborative effort with the University of Alaska - Fairbanks, NASA Goddard Space Flight Center, and our group at George Washington University is underway to monitor these feedbacks near Fairbanks, Alaska. In June 2017, we deployed two open-path tunable diode laser sensors at the Bonanza Long Term Ecological Research Site for measurement of CO2 and CH4 concentrations. The open-path instrument (OPI) is an inexpensive, low-power sensor that collects spatially-integrated measurements of target molecules approximately 1.5 meters above ground level. With a total power burden of 18 W, the sensors ran exclusively on solar power for 15 days in a young thermokarst bog and 3.5 days at a rich fen site. Here we report on initial retrieval of diurnal cycles from each field site and compare our spatially-integrated measurements of CO2 and CH4. For CO2, the magnitude of the diurnal cycles show a strong dependence on daily weather at both field sites. These laser measurements are complemented by point measurements of CO2, temperature, pressure, and humidity made along the laser's optical path by non-dispersive infrared (NDIR) sensors.
NASA Astrophysics Data System (ADS)
Hamish, A.; Christenson, B. W.; Mazot, A.
2014-12-01
The major volatile species in volcanic plume emissions (i.e., H2O, CO2, SO2, HCl, HF) are all strongly infrared (IR)-active, and lend themselves to infrared spectroscopic analysis. However, physical/optical access to plume gases along pathways which include a suitable natural or active IR radiation source is often difficult or impossible to achieve, particularly for timeframes extending beyond short campaign periods. In this study, we present results from preliminary tests conducted on three volcanic CO2 plume emissions using a tunable diode NIR laser system (TDL, Boreal Laser Inc.). The approach is proving itself as a good candidate for continuous monitoring of volcanic plume CO2, and by default all other IR-active constituents for which lasers of appropriate wavelength are available. The CO2 system is configured with a TDL in a transceiver generating laser light which can be tuned to coincide with one of several absorption lines in the CO2 absorption band between 1575 nm and 1585 nm. This beam propagates through the atmosphere (and plume) to a retro-reflector, which returns the beam to a photodiode detector in the transceiver which processes the signal to report real time CO2 column densities. The CO2 absorption line at 1579.1 nm was used to good effect on Mt Ruapehu (NZ) where volcanic gases emanate through a 100 m deep crater lake, resulting in CO2 concentrations of > 78 ppm above background in the mixing zone varying from 4 to 30 m above the lake surface. Subsequent tests on the main plume at White Island, however, generated only poor results with indicated CO2 amounts being less than atmospheric. We concluded that this was the result of interference from a neighboring but comparatively minor H2O absorption band which in the proximal, higher temperature plume (estimated 50-70 °C), had H2O concentrations some 4-5 times greater than ambient. A change to a less sensitive absorption line further removed from potential H2O band interference (1567.9 nm) appears to have solved this problem, and yielded maximum CO2 concentrations along the 730 m pathway in excess of 500 ppm.This approach holds promise for continuous, real-time monitoring of volcanic plume chemistry, and we will now turn our focus to the detection of SO2, HCl and HF plume species.
CO2 laser annealing of 50-microns-thick silicon solar cells
NASA Technical Reports Server (NTRS)
Walker, F. E.
1979-01-01
A test program is conducted to determine thin solar cell annealing effects using a laser energy source. A CO2 continuous-wave laser was used in annealing experiments on 50 micrometers-thick silicon solar cells after proton irradiation. Test cells were irradiated to a fluence of 1.0 x 10 to the 12th power protons/sq cm with 1.9 MeV protons. After irradiation, those cells receiving full proton dosage were degraded by an average of 30% in output power. In annealing tests laser beam exposure times on the solar cell varied from 2 seconds to 16 seconds reaching cell temperatures of from 400 C to 500 C. Under those conditions annealing test results showed recovery in cell output power of from 33% to 90%.
Azevedo, Ana-Salvaterra; Ferreira, Fernando; Delgado, Maria-Leonor; Garcês, Fernanda; Carreira, Sofia; Martins, Marco; Suarez-Quintanilla, Juan
2016-01-01
Background Lasers have become standard tools for the surgical treatment of oral lesions. The purpose of this study is to determine the surgical margins and histologically evaluate the tissue thermal effects induced by different types of surgical instruments. Material and Methods Cuts were made in pork tongues’ mucosa with different lasers (Er:YAG at 2W with and without air / water spray and at 4W with and without air / water spray; CO2 at 3.5W and 7W in pulsed mode and at 7W in continuous mode; the diode laser at 3.5W and boost 3.5W in pulsed mode; Nd:YAG at 6W, 40Hz and electroscalpel at 5W and conventional scalpel as control. Macroscopic and microscopic morphological changes were evaluated. Results The results of this study showed that the surgical instruments that caused greater tissue damage extension were: the Nd:YAG laser (670.68μm), the diode 3.5W and boost PW (626.82μm), the CO2 7W CW (571.18μm), the CO2 at 7W PW (485.45μm), the diode 3.5W PW (456.15μm), the electroscalpel (409.57μm) and lastly the CO2 laser 3.5W PW (306.19μm) and Er:YAG (74.66μm) laser, regardless of power, mode or air / water spray used. An association between the Tissue Damage Extension and the Degree of Carbonization (r = 0.789; P = 0.01), and an association between the Tissue Damage Extension and Regularity of the Incision were found (r = -, 299; P = 0.01). Conclusions The results of this study suggest that lasers can be used in soft tissues biopsies of the oral cavity, enabling a correct histopathological analysis, as long as the biological effects of each laser type are considered. The Er:YAG laser revealed its potential for biopsies of the oral mucosa ensuring a successful histological evaluation and the CO2 laser at 3,5W in pulsed mode presented itself as the best choice for surgeries with hemostasis. Key words:CO2 laser, diode laser, Er:YAG laser, laser surgery, Nd:YAG laser, oral mucosa, thermal effect. PMID:27703606
Fox, Sara A; Shanblatt, Ashley A; Beckman, Hugh; Strasswimmer, John; Terentis, Andrew C
2014-12-01
The number of cases of non-melanoma skin cancer (NMSC), which include squamous cell carcinoma (SCC) and basal cell carcinoma (BCC), continues to rise as the aging population grows. Mohs micrographic surgery has become the treatment of choice in many cases but is not always necessary or feasible. Ablation with a high-powered CO2 laser offers the advantage of highly precise, hemostatic tissue removal. However, confirmation of complete cancer removal following ablation is difficult. In this study we tested for the first time the feasibility of using Raman spectroscopy as an in situ diagnostic method to differentiate NMSC from normal tissue following partial ablation with a high-powered CO2 laser. Twenty-five tissue samples were obtained from eleven patients undergoing Mohs micrographic surgery to remove NMSC tumors. Laser treatment was performed with a SmartXide DOT Fractional CO2 Laser (DEKA Laser Technologies, Inc.) emitting a wavelength of 10.6 μm. Treatment levels ranged from 20 mJ to 1200 mJ total energy delivered per laser treatment spot (350 μm spot size). Raman spectra were collected from both untreated and CO2 laser-treated samples using a 785 nm diode laser. Principal Component Analysis (PCA) and Binary Logistic Regression (LR) were used to classify spectra as originating from either normal or NMSC tissue, and from treated or untreated tissue. Partial laser ablation did not adversely affect the ability of Raman spectroscopy to differentiate normal from cancerous residual tissue, with the spectral classification model correctly identifying SCC tissue with 95% sensitivity and 100% specificity following partial laser ablation, compared with 92% sensitivity and 60% selectivity for untreated NMSC tissue. The main biochemical difference identified between normal and NMSC tissue was high levels of collagen in the normal tissue, which was lacking in the NMSC tissue. The feasibility of a combined high-powered CO2 laser ablation, Raman diagnostic procedure for the treatment of NMSC is demonstrated since CO2 laser treatment does not hinder the ability of Raman spectroscopy to differentiate normal from diseased tissue. This combined approach could be employed clinically to greatly enhance the speed and effectiveness of NMSC treatment in many cases. © 2014 Wiley Periodicals, Inc.
Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube.
Sosis, M B; Braverman, B; Caldarelli, D D
1996-07-01
The risk of an endotracheal tube's combustion during laser airway surgery necessitates the use of special anesthetic techniques and equipment to prevent this complication. This study was designed to evaluate the Laser-Trach(TM), a new laser-resistant rubber endotracheal tube for use during laser airway surgery. The Laser-Trach endotracheal tubes that were evaluated were size 6.0 mm internal diameter (ID) red rubber endotracheal tubes which had been commercially wrapped by Kendall-Sheridan (Mansfield, Mass.) with copper foil tape and overwrapped with fabric. The fabric layer was saturated with water prior to our tests, as recommended by the manufacturer. The Laser-Trach endotracheal tubes were compared with plain (bare) size 6.0 mm ID Rusch red rubber endotracheal tubes. The tubes under study were positioned horizontally on wet towels in air and had 5 L x min(-1) of oxygen flowing through them. They were subjected to continuous laser radiation at 40 W from either a CO2 or an Nd-YAG laser. The Nd-YAG laser was propagated via a 600-micron fiber bundle. Each laser was directed perpendicularly at the shaft of the endotracheal tube being studied, and its output was continued until a blowtorch fire occurred or 60 seconds had elapsed. Sixty seconds of CO2 laser fire did not ignite any of the eight Laser-Trach endotracheal tubes tested. However, blowtorch ignition of all eight bare rubber tubes tested occurred after 0.87 +/- 0.21 (mean +/- SD) seconds of CO2 laser fire. Nd-YAG laser contact with the Laser-Trach endotracheal tubes caused the perforation and blowtorch ignition of all eight tubes tested after 18.79 +/- 7.83 seconds. This was a significantly (P<.05) longer time than the 5.45 +/- 4.75 seconds required for the blowtorch ignition of all eight plain rubber endotracheal tubes tested with the Nd-YAG laser. Our results show that under the conditions of this study, the shafts of the Kendall-Sheridan Laser-Trach endotracheal tubes were resistant to the C02 laser. However, this endotracheal tube is not recommended for use with the Nd-YAG laser.
DAWN Coherent Wind Profiling Lidar Flights on NASA's DC-8 During GRIP
NASA Technical Reports Server (NTRS)
Kavaya, Michael J.; Beyon, Jeffrey Y.; Creary, Garfield A.; Koch, Grady J.; Petros, Mulugeta; Petzar, Paul J.; Singh, Upendra N.; Trieu, Bo C.; Yu, Jirong
2011-01-01
Almost from their invention, lasers have been used to measure the velocity of wind and objects; over distances of cm to 10s of km. Long distance (remote) sensing of wind has been accomplished with continuous-wave (CW), focused pulsed, and collimated pulsed lasers; with direct and coherent (heterodyne) optical detection; and with a multitude of laser wavelengths. Airborne measurement of wind with pulsed, coherent-detection lidar was first performed in 1971 with a CW CO2 laser1, in 1972 with a pulsed CO2 laser2, in 1993 with a pulsed 2-micron laser3, and in 1999 with a pulsed CO2 laser and nadir-centered conical scanning4. Of course there were many other firsts and many other groups doing lidar wind remote sensing with coherent and direct detection. A very large FOM coherent wind lidar has been built by LaRC and flown on a DC-8. However a burn on the telescope secondary mirror prevented the full demonstration of high FOM. Both the GRIP science product and the technology and technique demonstration from aircraft are important to NASA. The technology and technique demonstrations contribute to our readiness for the 3D Winds space mission. The data analysis is beginning and we hope to present results at the conference.
De Rosa, Maurizio; Gagliardi, Gianluca; Rocco, Alessandra; Somma, Renato; De Natale, Paolo; De Natale, Giuseppe
2007-01-01
We report on a continuous-measurement campaign carried out in Vulcano (Aeolian islands, Sicily), devoted to the simultaneous monitoring of CO2 and H2O concentrations. The measurements were performed with an absorption spectrometer based on a semiconductor laser source emitting around a 2-μm wavelength. The emitted radiation was selectively absorbed by two molecular ro-vibrational transitions specific of the investigated species. Data for CO2 and H2O concentrations, and CO2 soil diffusive flux using an accumulation chamber configuration, were collected at several interesting sampling points on the island (Porto Levante beach- PLB, Fossa Grande Crater – FOG- and Valley of Palizzi, PAL). CO2/H2O values, measured on the ground, are very similar (around 0.019 (± 0.006)) and comparable to the previous discrete detected values of 0.213 (Fumarole F5-La Fossa crater rim) and 0.012 (Fumarole VFS – Baia Levante beach) obtaid during the 1977–1993 heating phase of the crater fumaroles. In this work much more homogeneous values are found in different points of the three sites investigated. The field work, although carried out in a limited time window (25th–28th August 2004), pointed out the new apparatus is suitable for continuous gas monitoring of the two species and their ratios, which are important geochemical indicators of volcanic activity, for which other reliable continuous monitoring systems are not yet available. PMID:17448243
Belal, Mahmoud Helmy; Watanabe, Hisashi
2014-10-01
Clinical application of lasers in periodontal therapy has continued to expand in last decades; however there are still some controversies. The present study aimed to compare the conditioning effects of the carbon dioxide (CO2) or erbium-doped: yttrium, aluminum and garnet (Er:YAG) laser on periodontally diseased root surfaces following scaling and root planing (SRP) in terms of the alteration of morphologies as well as the attachment of periodontal ligament cells. Forty-five periodontally affected root specimens were prepared and randomly assigned into three groups: I control (untreated diseased), II. SRP+CO2 laser (pulsed, noncontact mode), and III. SRP+Er:YAG laser (slight contact mode). After treatment, five specimens in each group were used for surface topographic examination. The remaining 10 specimens in each group were incubated with human periodontal ligament cell suspension. All the specimens were finally evaluated by scanning electron microscopy. The control specimens showed the lowest number of cultured cells, mostly in oval shape, with no tightly attached cells. The CO2 lased specimens showed a significant increase in the number of attached cells compared with controls, but demonstrated some major thermal alterations on the surfaces. The Er:YAG lased specimens showed the significantly highest number of attached cells, mostly in flat form, and did not show distinct thermal damage. The present study suggests that compared with the CO2 laser, the Er:YAG laser may constitute a more useful conditioning tool for enhancing periodontal cell attachment to periodontally diseased root surfaces, with fewer undesirable thermal side effects.
Research on radiation induced laser plasmas
NASA Technical Reports Server (NTRS)
Schneider, R. T.; Rowe, M. J.; Carter, B. D.; Walters, R. A.; Cox, J. D.; Liang, R.; Roxey, T.; Zapata, L.
1979-01-01
The development of high power nuclear pumped lasers is discussed. The excitation mechanism of continuous wave (CW) HeNe nuclear pumped lasers is studied and a CO2 nuclear pumped laser is used to demonstrate the CW output in the order of watts. The assumption that high power densities are only achievable by volume fission fragment sources is used to identify laser gases which are compatible with UF6 by excited states lifetime measurements. The examination of Xe2, XeF, and KrF under nuclear irradiation to determine if they are good candidates for nuclear-pumped lasers is described.
The NASA high power carbon dioxide laser: A versatile tool for laser applications
NASA Technical Reports Server (NTRS)
Lancashire, R. B.; Alger, D. L.; Manista, E. J.; Slaby, J. G.; Dunning, J. W.; Stubbs, R. M.
1976-01-01
A closed-cycle, continuous wave, carbon dioxide high power laser has been designed and fabricated to support research for the identification and evaluation of possible high power laser applications. The device is designed to generate up to 70 kW of laser power in annular shape beams from 1 to 9 cm in diameter. Electric discharge, either self sustained or electron beam sustained, is used for excitation. This laser facility provides a versatile tool on which research can be performed to advance the state-of-the-art technology of high power CO2 lasers in such areas as electric excitation, laser chemistry, and quality of output beams. The facility provides a well defined, continuous wave beam for various application experiments, such as propulsion, power conversion, and materials processing.
Theerasopon, Pornpat; Wangsrimongkol, Tasanee; Sattayut, Sajee
2017-03-31
Although surgical treatment protocols for cleft lip and palate patients have been established, many patients still have some soft tissue defects after complete healing from surgical interventions. These are excess soft tissue, high attached fraena and firmed tethering scares. These soft tissue defects resulted shallowing of vestibule, restricted tooth movement, compromised periodontal health and trended to limit the maxillary growth. The aim of this case report was to present a method of correcting soft tissue defects after conventional surgery in cleft lip and palate patient by using combined laser surgery and orthodontic appliance. A bilateral cleft lip and palate patient with a clinical problem of shallow upper anterior vestibule after alveolar bone graft received a vestibular extension by using CO 2 laser with ablation and vaporization techniques at 4 W and continuous wave. A customized orthodontic appliance, called a buccal shield, was placed immediately after surgery and retained for 1 month to 3 months until complete soft tissue healing. The procedures were performed 2 episodes. Both interventions used the same CO 2 laser procedure. The first treatment resulted in partial re-attachment of soft tissue at surgical area. The second laser operation with the proper design of buccal shield providing passive contact with more extended flange resulting in a favorable outcome from 1 year follow up. Then the corrective orthodontic treatment could be continued effectively. The CO 2 laser surgery was a proper treatment for correcting soft tissue defects and the design of buccal shield was a key for success in molding surgical soft tissue.
Low SWaP Semiconductor Laser Transmitter Modules For ASCENDS Mission Applications
NASA Technical Reports Server (NTRS)
Prasad, Narasimha S.; Rosiewicz, Alex; Coleman, Steven M.
2012-01-01
The National Research Council's (NRC) Decadal Survey (DS) of Earth Science and Applications from Space has identified the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as an important atmospheric science mission. NASA Langley Research Center, working with its partners, is developing fiber laser architecture based intensity modulated CW laser absorption spectrometer for measuring XCO2 in the 1571 nm spectral band. In support of this measurement, remote sensing of O2 in the 1260 nm spectral band for surface pressure measurements is also being developed. In this paper, we will present recent progress made in the development of advanced transmitter modules for CO2 and O2 sensing. Advanced DFB seed laser modules incorporating low-noise variable laser bias current supply and low-noise variable temperature control circuit have been developed. The 1571 nm modules operate at >80 mW and could be tuned continuously over the wavelength range of 1569-1574nm at a rate of 2 pm/mV. Fine tuning was demonstrated by adjusting the laser drive at a rate of 0.7 pm/mV. Heterodyne linewidth measurements have been performed showing linewidth 200 kHz and frequency jitter 75 MHz. In the case of 1260 nm DFB laser modules, we have shown continuous tuning over a range of 1261.4 - 1262.6 nm by changing chip operating temperature and 1261.0 - 1262.0 nm by changing the laser diode drive level. In addition, we have created a new laser package configuration which has been shown to improve the TEC coefficient of performance by a factor of 5 and improved the overall efficiency of the laser module by a factor of 2.
NASA Technical Reports Server (NTRS)
Opower, Hans (Editor)
1990-01-01
Recent advances in CO2 laser technology and its applications are examined. Topics discussed include the excitation of CO2 lasers by microwave discharge, a compact RF-excited 12-kW CO2 laser, a robotic laser for three-dimensional cutting and welding, three-dimensional CO2-laser material processing with gantry machine systems, and a comparison of hollow metallic waveguides and optical fibers for transmitting CO2-laser radiation. Consideration is given to an aerodynamic window with a pump cavity and a supersonic jet, cutting and welding Al using a high-repetition-rate pulsed CO2 laser, speckle reduction in CO2 heterodyne laser radar systems, high-power-laser float-zone crystal growth, melt dynamics in surface processing with laser radiation, laser hardfacing, surface melting of AlSi10Mg with CO2 laser radiation, material processing with Cu-vapor lasers, light-induced flow at a metal surface, and absorption measurements in high-power CW CO2-laser processing of materials.
NASA Astrophysics Data System (ADS)
Cobb, Charles M.; Spencer, Paulette; McCollum, Mark H.
1995-05-01
Specimens consisted of 18 extracted single rooted teeth unaffected by periodontal disease. After debriding roots, specimens were randomly divided into 4 treatment groups and subjected to a single pass, at varying energy densities, of a CO2, Nd:YAG, and Nd:YAG with air/water surface cooling (Nd:YAG-C). The rate of exposure was controlled at 4 mm/sec. Approximate energy densities were: CO2, 138, 206, 275, and 344 J/cm2; Nd:YAG, 114, 171, 229, and 286 J/cm2; Nd:YAG-C, 286, 343, 514, and 571 J/cm2. The CO2 laser was used both in continuous and pulsed beam modes (20 Hz, 0.01 sec pulse length and 0.8 mm dia spot size) whereas the Nd:YAG and Nd:YAG-C were preset at 50 Hz, 0.08 sec pulse length and 0.6 mm dia spot size. Specimen examination by SEM revealed, for all lasers, a direct correlation between increasing energy densities and depth of tissue ablation and width of tissue damage. However, to achieve the same relative dept of tissue ablation, the Nd:YAG-C required higher energy densities than either the CO2 or Nd:YAG lasers. The Nd:YAG-C generated a cavitation with sharply defined margins. Furthermore, regardless of energy density, and in contrast with other laser types, areas treated with the Nd:YAG-C did not exhibit collateral zones of heat damaged surface tissue.
In vitro study of root fracture treated by CO2 laser and DP-bioactive glass paste.
Wang, Yin-Lin; Lee, Bor-Shiunn; Tseng, Ching-Li; Lin, Feng-Huei; Lin, Chun-Pin
2008-01-01
An ideal material has yet to be discovered that can successfully treat vertical root fracture. Therefore, the purpose of this study was to use a continuous-wave CO2 laser of medium-energy density to fuse DP-bioactive glass paste (DPGP) to vertical root fracture. The DP-bioglass powder was based on a Na2O-CaO-SiO2-P2O5 system and it was mixed with phosphoric acid (65% concentration) with a powder/liquid ratio of 2 g/4 mL to form DPGP. The interaction of DPGP and dentin was analyzed by means of X-ray diffractometer (XRD) and differential thermal analysis/thermogravimetric analysis (DTA/TGA). Root fracture line was filled with DPGP followed by CO2 laser irradiation and the result was examined by scanning electron microscopy (SEM). The main crystal phase of DPGP was monocalcium phosphate monohydrate (Ca(H2PO4)2.H2O) and the phase transformed to dicalcium phosphate dihydrate (CaHPO4.2H2O) after mixing DPGP with dentin powder (DPG-D). Additionally, gamma-Ca2P2O7 and beta-Ca2P2O7 were identified when DPG-D was lased by CO2 laser. The reaction temperature was between 500 degrees C and 1100 degrees C. SEM results demonstrated that the fracture line was effectively sealed by DPGP. The chemical reaction of DPGP and dentin indicated that DPGP combined with CO2 laser is a potential regimen for the treatment of vertical root fracture.
NASA Astrophysics Data System (ADS)
Nelson, David; McManus, Barry; Shorter, Joanne; Zahniser, Mark; Ono, Shuhei
2014-05-01
The capacity for real time precise in situ measurements of isotopic ratios of a variety of trace gases at ambient concentrations continues to create new opportunities for the study of the exchanges and fluxes of gases in the environment. Aerodyne Research has made rapid progress in laser based instruments since our introduction in 2007 of the first truly field worthy instrument for real time measurements of isotopologues of carbon dioxide. We have focused on two instrument design platforms, with either one or two lasers. Absorption cells with more than 200 meters path length allow precise measurements of trace gases with low ambient concentrations. Most of our systems employ mid infrared quantum cascade lasers. However, recently available 3 micron antimonide based diode lasers are also proving useful for isotopic measurements. By substituting different lasers and detectors, we can simultaneously measure the isotopic composition of a variety of gases, including: H2O, CO2, CH4, N2O and CO. Our newest instrument for true simultaneous measurement of isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) has (1 s) precision better than 0.1 per mil for both ratios. The availability of 10 Hz measurements allows measurement of isotopic fluxes via eddy correlation. The single laser instrument fits in a 19 inch rack and is only 25 cm tall. A two laser instrument is larger, but with that instrument we can also measure clumped isotopes of CO2, with 1 second precisions of: 2.3 per mil for 13C18O16O, and 6.7 per mil for 13C17O16O. The sample size for such a measurement corresponds to 0.2 micromole of pure CO2. Another variation on the two laser instrument simultaneously measures isotopologues of CO2 (12CO2, 13CO2, 12C18O16O) and H2O (H216O, H218O, HD16O). Preliminary results for water ratio precisions (in 1s) are 0.1 per mil for H218O and 0.3 per mil for HD16O, simultaneous (1 s) precisions for isotopologues of CO2 of ~0.1 per mil. Methane, nitrous oxide and carbon monoxide have such low ambient concentrations that real-time isotopologue measurements are a serious challenge. For these gases, we typically use our 200 m absorption cell. Several of these instruments have already been used for long term field measurements of isotopologues of methane, (12CH4, 13CH4), with a demonstrated (1 s) precision of 1.5 per mil. A new version of this instrument operating near 3.3 microns has recently been developed to quantify 13CH4 and CH3D simultaneously. In separate experiments at MIT, using trapped concentrated samples, we have made highly precise measurements of the abundance of the clumped isotope of methane: 13CH3D. We are also developing methods to monitor the isotopic abundance of the isotopes of CO and N2O. We have achieved a measurement precision for ambient 13CO (1 s) of 1.9 per mil. For the isotopologues of N2O (14N216O, 14N15N 16O, 15N14N 16O, 14N218O), we have demonstrated (1 s) precision at ambient levels (320 ppb) of ~3 per mil. For N2O, a quasi continuous preconcentrator has been used to give even better precisions (<0.1 per mil) and one is being developed for CO.
[Examination of laser-treated tooth surfaces after exposure to acid].
Beeking, P O; Herrmann, C; Zuhrt, R
1990-12-01
In principle it is possible to homogenize the enamel surface by melting structural elements with the continuous wave CO2 laser. An experimental caries model was used for testing the acid resistance of the laser exposed tooth surfaces. Laser-treatment and measured exposure to acid produced zones of homogeneous smelting with microcracks and disintegration symptoms. Underneath the melted region the heat leakage obviously causes photo-thermic++ effects determined by increased resistance to acid.
NASA Astrophysics Data System (ADS)
Kahlen, Franz-Josef; Sankaranarayanan, Srikanth; Kar, Aravinda
1997-09-01
Subject of this investigation is a one-step rapid machining process to create miniaturized 3D parts, using the original sample material. An experimental setup where metal powder is fed to the laser beam-material interaction region has been built. The powder is melted and forms planar, 2D geometries as the substrate is moved under the laser beam in XY- direction. After completing the geometry in the plane, the substrate is displaced in Z-direction, and a new layer of material is placed on top of the just completed deposit. By continuous repetition of this process, 3D parts wee created. In particular, the impact of the focal spot size of the high power laser beam on the smallest achievable structures was investigated. At a translation speed of 51 mm/s a minimum material thickness of 590 micrometers was achieved. Also, it was shown that a small Z-displacement has a negligible influence on the continuity of the material deposition over this power range. A high power CO2 laser was used as energy source, the material powder under investigation was stainless steel SS304L. Helium was used as shield gas at a flow rate of 15 1/min. The incident CO2 laser beam power was varied between 300 W and 400 W, with the laser beam intensity distribute in a donut mode. The laser beam was focused to a focal diameter of 600 (Mu) m.
NASA Astrophysics Data System (ADS)
Zaikin, A. E.; Levin, A. V.; Petrov, A. L.
1995-02-01
A surface optical-discharge plasma was formed in a metal vapour under normal conditions by steady-state irradiation with a cw CO2 laser delivering radiation of moderate (2-4.5 MW cm-2) intensity. This plasma strongly screened the irradiated surface. Under the selected experimental conditions the optical discharge was not a continuous (steady-state) process. The plasma cloud was displaced along the beam out of the waist to a region where the laser radiation intensity was almost an order of magnitude less than the threshold for excitation of the optical-discharge plasma in the vapour. A strong screening of the metal surface, which could even completely stop evaporation of the metal, was observed. Self-oscillations of the optical-discharge plasma were observed for the first time in a vapour interacting with cw CO2 radiation: this was attributed to screening of the target surface. Within one period of the self-oscillations there were additional hf plasma pulsations which led to stratification of the plasma cloud. The results obtained were interpreted.
Feasibility study of a CO2-laser based lightning-protection system realization
NASA Astrophysics Data System (ADS)
Apollonov, Victor V.
2005-01-01
The feasibility of producing a continuous laser spark (CLS) with low resistance by focusing radiation from a CO2 laser with a conic mirror is demonstrated. The laser energy input per unit length required for this is experimentally found to be equal to ≈200 J/m. The possibility to efficiently control the trajectory of an electric discharge by means of a CLS is demonstrated. The effect of polarity in the electric breakdown of the air gaps between the CLS plasma channel and a metal rod is discovered and interpreted. The transverse structure of CLS conductivity is investigated. The possibility of producing a long laser spark (LLS) with much higher resistance by focusing radiation from a CO2 laser with a spherical mirror used to protect objects against lightning is studied. The conditions under which the electric discharges from clouds can be guided reproducibly along a LLS are determined. Experiments reveal that the interaction between the LLS and the discharge from an electrode (lightning rod) leads to a decrease in the lifetime of the streamer corona burst, as well as to an increase in the current of the developing leader and its velocity compared to the case without the LLS.
Laser beam-plasma plume interaction during laser welding
NASA Astrophysics Data System (ADS)
Hoffman, Jacek; Moscicki, Tomasz; Szymanski, Zygmunt
2003-10-01
Laser welding process is unstable because the keyhole wall performs oscillations which results in the oscillations of plasma plume over the keyhole mouth. The characteristic frequencies are equal to 0.5-4 kHz. Since plasma plume absorbs and refracts laser radiation, plasma oscillations modulate the laser beam before it reaches the workpiece. In this work temporary electron densities and temperatures are determined in the peaks of plasma bursts during welding with a continuous wave CO2 laser. It has been found that during strong bursts the plasma plume over the keyhole consists of metal vapour only, being not diluted by the shielding gas. As expected the values of electron density are about two times higher in peaks than their time-averaged values. Since the plasma absorption coefficient scales as ~N2e/T3/2 (for CO2 laser radiation) the results show that the power of the laser beam reaching the metal surface is modulated by the plasma plume oscillations. The attenuation factor equals 4-6% of the laser power but it is expected that it is doubled by the refraction effect. The results, together with the analysis of the colour pictures from streak camera, allow also interpretation of the dynamics of the plasma plume.
Study, optimization, and design of a laser heat engine. [for satellite applications
NASA Technical Reports Server (NTRS)
Taussig, R. T.; Cassady, P. E.; Zumdieck, J. F.
1978-01-01
Laser heat engine concepts, proposed for satellite applications, are analyzed to determine which engine concept best meets the requirements of high efficiency (50 percent or better), continuous operation in space using near-term technology. The analysis of laser heat engines includes the thermodynamic cycles, engine design, laser power sources, collector/concentrator optics, receiving windows, absorbers, working fluids, electricity generation, and heat rejection. Specific engine concepts, optimized according to thermal efficiency, are rated by their technological availability and scaling to higher powers. A near-term experimental demonstration of the laser heat engine concept appears feasible utilizing an Otto cycle powered by CO2 laser radiation coupled into the engine through a diamond window. Higher cycle temperatures, higher efficiencies, and scalability to larger sizes appear to be achievable from a laser heat engine design based on the Brayton cycle and powered by a CO laser.
NASA Astrophysics Data System (ADS)
Bereiter, Bernhard; Maechler, Lars; Schmitt, Jochen; Walther, Remo; Tuzson, Béla; Scheidegger, Philipp; Emmenegger, Lukas; Fischer, Hubertus
2017-04-01
Ice cores are unique archives of ancient air providing the only direct record of past greenhouse gases - key in reconstructing the roles of greenhouse gases in past climate changes. The European Partnership in Ice Core Sciences (EuroPICS) plans to drill an ice core extending over 1.5 Ma, nearly doubling the time span of the existing greenhouse record and covering the time period of the Mid Pleistocene Transition. The ice covering the time interval from 1-1.5 Ma is expected to be close to the bedrock and, due to glacial flow, extremely thinned. A 10,000 yr glacial/interglacial transition can be compressed in 1 m of ice. The targeted 100 yr resolution therefore constrains the sample size to 15-30 g containing only 1-2ml STP air. Within the deepSlice project we aim to unlock such atmospheric archives in extremely thinned ice by developing a novel coupled semi-continuous sublimation extraction/laser spectroscopy system. Vacuum sublimation, with an infrared source, has been chosen as extraction method as it allows 100% gas extraction of all gas species from ice without changing the isotopic composition of CO2. In order to reduce ice waste and accelerate sample throughput, we are building a sublimation extraction system that is able to continuously sublimate an ice-core section and subsequently collect discrete full air samples. For the gas analytics, we develop a custom-made mid-infrared laser spectrometer allowing simultaneous measurement of the CO2, CH4 and N2O concentrations as well as the isotopic composition of CO2 on air samples of only 1-2 ml STP. The two systems will be coupled via cryo-trapping of the sample air in dip tubes, followed by expansion of the sample air into the laser spectrometer. Due to the nondestructive laser technique, the air sample can be recollected and reused for further analytics.
Screening of CO2 Laser (10.6 μm) Parameters for Prevention of Enamel Erosion
Yu, Hao; de Paula Eduardo, Carlos; Meister, Jörg; Lampert, Friedrich; Attin, Thomas; Wiegand, Annette
2012-01-01
Abstract Objective: The aim of this study was to screen CO2 laser (10.6 μm) parameters to increase enamel resistance to a continuous-flow erosive challenge. Background data: A new clinical CO2 laser providing pulses of hundreds of microseconds, a range known to increase tooth acid-resistance, has been introduced in the market. Methods: Different laser parameters were tested in 12 groups (n=20) with varying fluences from 0.1 to 0.9 J/cm2, pulse durations from 80 to 400 μs and repetition rates from 180 to 700 Hz. Non-lased samples (n=30) served as controls. All samples were eroded by exposure to hydrochloric acid (pH 2.6) under continuous acid flow (60 μL/min). Calcium and phosphate release into acid was monitored colorimetrically at 30 sec intervals up to 5 min and at 1 min intervals up to a total erosion time of 15 min. Scanning electron microscopic (SEM) analysis was performed in lased samples (n=3). Data were statistically analysed by one-way ANOVA (p<0.05) and Dunnett's post-hoc tests. Results: Calcium and phosphate release were significantly reduced by a maximum of 20% over time in samples irradiated with 0.4 J/cm2 (200μs) at 450 Hz. Short-time reduction of calcium loss (≤1.5 min) could be also achieved by irradiation with 0.7 J/cm2 (300μs) at 200 and 300 Hz. Both parameters revealed surface modification. Conclusions: A set of CO2 laser parameters was found that could significantly reduce enamel mineral loss (20%) under in vitro erosive conditions. However, as all parameters also caused surface cracking, they are not recommended for clinical use. PMID:22462778
Latest developments for low-power infrared laser-based trace gas sensors for sensor networks
NASA Astrophysics Data System (ADS)
So, Stephen; Thomazy, David; Wang, Wen; Marchat, Oscar; Wysocki, Gerard
2011-09-01
Academic and industrial researchers require ultra-low power, compact laser based trace-gas sensor systems for the most demanding environmental and space-borne applications. Here the latest results from research projects addressing these applications will be discussed: 1) an ultra-compact CO2 sensor based on a continuous wave quantum cascade laser, 2) an ultra-sensitive Faraday rotation spectrometer for O2 detection, 3) a fully ruggedized compact and low-power laser spectrometer, and 4) a novel non-paraxial nonthin multipass cell. Preliminary tests and projection for performance of future sensors based on this technology is presented.
High-damage-threshold antireflection coatings on diamond for CW and pulsed CO2 lasers
NASA Astrophysics Data System (ADS)
Komlenok, M. S.; Pivovarov, P. A.; Volodkin, B. O.; Pavelyev, V. S.; Anisimov, V. I.; Butuzov, V. V.; Sorochenko, V. R.; Nefedov, S. M.; Mineev, A. P.; Soifer, V. A.; Konov, V. I.
2018-03-01
A multilayer antireflection coating for diamond optics that allows work in the infrared spectral range of 8 -12 µm with minimal optical losses is developed. The optical transmittance of a chemical vapour deposition diamond plate coated with this film on both sides exceeds 94% over the whole specified wavelength range. The coatings deposited on the diamond plate were damage-tested by coherent-wave and pulsed (τ = 90 ns) CO2 lasers. Results of the tests demonstrated that the coating can withstand prolonged radiation loads with intensity above 3 MW cm-2 in a continuous-mode laser exposure. In the case of a nanosecond pulsed action, destruction of the coating begins at intensities greater than 50 MW cm-2.
Karimi, Abbas; Sobouti, Farhad; Torabi, Sara; Bakhshandehfard, Ali; Amirian, Armaghan; Shariati, Mahsa; Morshedi, Ehsan; Barati, Maryam
2016-01-01
Introduction: Epulis fissuratum is often formed as a result of a poor fitting denture. The conventional treatment for this fibrous hyperplastic tissue is to excise it using a scalpel and to close the wound by a continuous or an interrupted suture. The increased utilization of lasers in dentistry also includes the utilization of carbon dioxide (CO2) lasers in place of surgical scalpels in soft tissue surgeries. The objective of this study is to assess the feasibility of utilizing CO2 laser in place of scalpel in surgical treatment of epulis fissuratum. Methods: In this clinical trial research (IRCT code: IRCT2016071124969N2), 19 patients were selected with nearly symmetrical epulis fissuratums in the anterior part of the jaws. The hyperplastic tissue was evenly divided into two sections in each patient. One section was randomly selected and cut by CO2 laser and the other section by a surgical scalpel. The wound created by the scalpel was closed by appropriate number of interrupted sutures. Surgery duration and bleeding as well as vestibular depth, re-epithelialization and edema in both sections were noted and recorded after 7 and 14 days postoperatively. Results: The time of surgery and the amount of bleeding during surgery in the laser section was less and the vestibular depth was more than surgical scalpel section (P < 0.05). Surgical scalpel wound at day seventh healed significantly better than the section treated by the CO2 laser (P < 0.05). Wound in both sections healed similarly on day 14 and no statistical difference was observed. Edema presence was also equal in both sides after 7th and 14th following the surgery. Conclusion: According to the results it could be concluded that the use of CO2 laser may result in less surgery time, less bleeding during surgery, more vestibular depth, better re-epithelialization of the wound and less need for suturing. CO2 laser may be a clinically preferred method for surgical treatment of epulis fissuratum. PMID:28144443
NASA Astrophysics Data System (ADS)
Al-Hawat, Sharif
2013-02-01
Infrared (IR) absorption in the spectral range of (1071.88-1084.62 cm-1) vs. pressure in chlorodifluoromethane (CFC-22, F-22, and CHClF2) was studied using a tunable continuous wave (CW) CO2 laser radiation on 9R branch lines with a maximum output power of about 2.12 W, provided with an absorber cell located outside the laser cavity. The absorption coefficients were determined vs. the gas pressure between 0.2 mbar and 170 mbar at lines from 9R branch for CFC-22. The frequency shifts of the absorption lines of CFC-22 in relative to the central frequencies of laser lines were calculated vs. the pressure on the basis of these absorption coefficients. The chosen lines were selected according to IR spectrum of the studied gas given by HITRAN cross section database. So the absorption was achieved for CFC-22 at the spectral lines of 9R branch situated from 9R (10) to 9R (30) emitted by a tunable CW CO2 laser. The absorption cross sections of CFC-22 determined in this work were compared with the relevant data given by HITRAN cross section database and a reasonable agreement was observed.
Hemostatic properties of the free-electron laser
NASA Astrophysics Data System (ADS)
Cram, Gary P., Jr.; Copeland, Michael L.
1998-09-01
We have investigated the hemostatic properties of the free-electron laser (FEL) and compared these properties to the most commonly used commercial lasers in neurosurgery, CO 2 and Nd:YAG, using an acute canine model. Arterial and venous vessels, of varying diameters from 0.1 to 1.0 mm, were divided with all three lasers. Analysis of five wavelengths of the FEL (3.0, 4.5, 6.1, 6.45, and 7.7 microns) resulted in bleeding without evidence of significant coagulation, regardless of whether the vessel was an artery or vein. Hemorrhage from vessels less than 0.4 mm diameter was subsequently easily controlled with Gelfoam® (topical hemostatic agent) alone, whereas larger vessels required bipolar electrocautery. No significant charring, or contraction of the surrounding parenchyma was noted with any of the wavelengths chosen from FEL source. The CO 2 laser, in continuous mode, easily coagulated vessels with diameters of 4 mm and less, while larger vessels displayed significant bleeding requiring bipolar electrocautery for control. Tissue charring was noted with application of the CO 2 laser. In super pulse mode, the CO 2 laser exhibited similar properties, including significant charring of the surrounding parenchyma. The Nd:YAG coagulated all vessels tested up to 1.4 mm, which was the largest diameter cortical artery found, however this laser displayed significant and extensive contraction and retraction of the surrounding parenchyma. In conclusion, the FEL appears to be a poor hemostatic agent. Our results did not show any benefit of the FEL over current conventional means of achieving hemostasis. However, control of hemorrhage was easily achieved with currently used methods of hemostasis, namely Gelfoam® or bipolar electrocuatery. Although only cortical vessels in dogs were tested, we feel this data can be applied to all animals, including humans, and the peripheral, as well as central, vasculature, as our data on the CO 2 and Nd:YAG appear to closely support previous reports of hemostasis of these two lasers obtained in other models.
Generation conditions of CW Diode Laser Sustained Plasma
NASA Astrophysics Data System (ADS)
Nishimoto, Koji; Matsui, Makoto; Ono, Takahiro
2016-09-01
Laser sustained plasma was generated using 1 kW class continuous wave diode laser. The laser beam was focused on the seed plasma generated by arc discharge in 1 MPa xenon lamp. The diode laser has advantages of high energy conversion efficiency of 80%, ease of maintenance, compact size and availability of conventional quartz based optics. Therefore, it has a prospect of further development compared with conventional CO2 laser. In this study, variation of the plasma shape caused by laser power is observed and also temperature distribution in the direction of plasma radius is measured by optical emission spectroscopy.
Performance of a CW double electric discharge for supersonic CO lasers
NASA Technical Reports Server (NTRS)
Stanton, A. C.; Hanson, R. K.; Mitchner, M.
1980-01-01
The results of an experimental investigation of a CW double discharge in supersonic CO mixtures are reported. Stable discharges in CO/N2 and CO/Ar mixtures, with a maximum energy loading of 0.5 eV/CO molecule, were achieved in a small-scale continuous-flow supersonic channel. Detailed measurements of the discharge characteristics were performed, including electrostatic probe measurements of floating potential and electron number density and spectroscopic measurements of the CO vibrational population distributions. The results of these measurements indicate that the vibrational excitation efficiency of the discharge is approximately 60%, for moderate levels of main discharge current. These experiments, on a small scale, demonstrate that the double-discharge scheme provides adequate vibrational energy loading for efficient CO laser operation under CW supersonic flow conditions.
Esophageal incisions repair by CO2 laser soldering.
Nageris, Ben I; Zilker, Zeev; Zilker, Maya; Kariv, Noam; Feinmesser, Rafael; Katzir, Abraham
2004-12-01
This study evaluated the feasibility of fiberoptic CO2 laser soldering for the repair of esophageal injuries under tight temperature feedback control in an animal model. Healing was compared to conventional suture closure. A CO2 soldering system equipped with infrared transmitting silver halide fibers was used. The soldered tissue temperature was monitored continuously, and laser power was adjusted to provide constant temperature. The procedure was done with 50% bovine serum albumin solder. Longitudinal incisions measuring 8 to 10 mm were made under general anesthesia in the cervical esophagus of 25 rats. Twenty rats (group I) underwent laser tissue bonding; 8 of which were tested in a preliminary study to determine optimal laser parameters. In the remaining 5 rats (group II, controls), closure was performed with 1 layer of 6/0 Vicryl sutures. The rats were sacrificed 2, 3, 4, and 6 weeks postoperatively, and the esophagus was examined histologically. Optimal temperature was found to be 65 to 70 degrees C and optimal exposure time, 150 to 200 seconds. Laser soldering was successful in 9 of the 12 rats (75%) treated under optimal settings; suturing was successful in 4 of the 5 control rats (80%). There were no significant differences between the groups in healing or complication rates. These results indicate that the CO2 laser soldering technique is a valid option for the correction of esophageal tears or incisions in rats. The confirmation and extension of these findings in further studies with larger animals may ultimately lead to the routine in vivo use of temperature-controlled laser repair for the esophagus and other organs. This method lends itself to endoscopic bonding of tissues.
TEA CO2 laser machining of CFRP composite
NASA Astrophysics Data System (ADS)
Salama, A.; Li, L.; Mativenga, P.; Whitehead, D.
2016-05-01
Carbon fibre-reinforced polymer (CFRP) composites have found wide applications in the aerospace, marine, sports and automotive industries owing to their lightweight and acceptable mechanical properties compared to the commonly used metallic materials. Machining of CFRP composites using lasers can be challenging due to inhomogeneity in the material properties and structures, which can lead to thermal damages during laser processing. In the previous studies, Nd:YAG, diode-pumped solid-state, CO2 (continuous wave), disc and fibre lasers were used in cutting CFRP composites and the control of damages such as the size of heat-affected zones (HAZs) remains a challenge. In this paper, a short-pulsed (8 μs) transversely excited atmospheric pressure CO2 laser was used, for the first time, to machine CFRP composites. The laser has high peak powers (up to 250 kW) and excellent absorption by both the carbon fibre and the epoxy binder. Design of experiment and statistical modelling, based on response surface methodology, was used to understand the interactions between the process parameters such as laser fluence, repetition rate and cutting speed and their effects on the cut quality characteristics including size of HAZ, machining depth and material removal rate (MRR). Based on this study, process parameter optimization was carried out to minimize the HAZ and maximize the MRR. A discussion is given on the potential applications and comparisons to other lasers in machining CFRP.
Campolmi, Piero; Bonan, Paolo; Cannarozzo, Giovanni; Bassi, Andrea; Bruscino, Nicola; Arunachalam, Meena; Troiano, Michela; Lotti, Torello; Moretti, Silvia
2012-01-01
The CO2 laser has been used extensively in dermatological surgery over the past 30 years and is now recognised as the gold standard for soft tissue vaporization. Considering that the continuous wave CO2 laser delivery system and the newer “superpulsed” and scanned CO2 systems have progressively changed our practice and patient satisfaction, a long range documentation can be useful. Our experience has demonstrated that the use of CO2 laser involves a reduced healing time, an infrequent need for anaesthesia, reduced thermal damage, less bleeding, less inflammation, the possibility of intra-operative histologic and/or cytologic examination, and easy access to anatomically difficult areas. Immediate side effects have been pain, erythema, edema, typically see with older methods, using higher power. The percentage of after-treatment keloids and hypertrophic scars observed was very low (~1%) especially upon the usage of lower parameters. The recurrence of viral lesions (condylomas and warts) have been not more frequent than those due to other techniques. Tumor recurrence is minor compared with radiotherapy or surgery. This method is a valid alternative to surgery and/or diathermocoagulation for microsurgery of soft tissues. Our results are at times not consistent with those published in the literature, stressing the concept that multicentric studies that harmonization methodology and the patient selection are vital. PMID:22593693
Thermal damage produced by high-irradiance continuous wave CO2 laser cutting of tissue.
Schomacker, K T; Walsh, J T; Flotte, T J; Deutsch, T F
1990-01-01
Thermal damage produced by continuous wave (cw) CO2 laser ablation of tissue in vitro was measured for irradiances ranging from 360 W/cm2 to 740 kW/cm2 in order to investigate the extent to which ablative cooling can limit tissue damage. Damage zones thinner than 100 microns were readily produced using single pulses to cut guinea pig skin as well as bovine cornea, aorta, and myocardium. Multiple pulses can lead to increased damage. However, a systematic decrease in damage with irradiance, predicted theoretically by an evaporation model of ablation, was not observed. The damage-zone thickness was approximately constant around the periphery of the cut, consistent with the existence of a liquid layer which stores heat and leads to tissue damage, and with a model of damage and ablation recently proposed by Zweig et al.
NASA Technical Reports Server (NTRS)
Awtry, A. R.; Miller, J. H.
2002-01-01
The progress in the development of a sensor for the detection of trace air constituents to monitor spacecraft air quality is reported. A continuous-wave (cw), external-cavity tunable diode laser centered at 1.55 micrometers is used to pump an optical cavity absorption cell in cw-cavity ringdown spectroscopy (cw-CRDS). Preliminary results are presented that demonstrate the sensitivity, selectivity and reproducibility of this method. Detection limits of 2.0 ppm for CO, 2.5 ppm for CO2, 1.8 ppm for H2O, 19.4 ppb for NH3, 7.9 ppb for HCN and 4.0 ppb for C2H2 are calculated.
Portable Laser Spectrometer for Airborne and Ground-Based Remote Sensing of Geological CO2 Emissions
NASA Technical Reports Server (NTRS)
Queisser, Manuel; Burton, Mike; Allan, Graham R.; Chiarugi, Antonio
2017-01-01
A 24 kilogram, suitcase-sized, CW (Continuous Wave) Laser Remote Sensing Spectrometer (LARSS) with an approximately 2-kilometer range has been developed. It has demonstrated its flexibility in measuring both atmospheric CO2 from an airborne platform and terrestrial emission of CO2 from a remote mud volcano, Bledug Kuwu, Indonesia, from a ground-based sight. This system scans the CO2 absorption line with 20 discrete wavelengths, as opposed to the typical two-wavelength online-offline instrument. This multi-wavelength approach offers an effective quality control, bias control, and confidence estimate of measured CO2 concentrations via spectral fitting. The simplicity, ruggedness, and flexibility in the design allow for easy transportation and use on different platforms with a quick setup in some of the most challenging climatic conditions. While more refinement is needed, the results represent a stepping stone towards widespread use of active one-sided gas remote sensing in the earth sciences.
Laser Sounder for Measuring Atmospheric CO2 Concentrations: Progress Toward Ascends
NASA Technical Reports Server (NTRS)
Abshire, J. B.; Kawa, S. R.; Riris, H.; Allan, G. R.; Sun, X.; Stephen, M. A.; Wilson, E.; Burris, J. F.; Mao, J.
2008-01-01
The next generation of space-based, active remote sensing instruments for measurement of tropospheric CO2 promises a capability to quantify global carbon sources and sinks at regional scales. Active (laser) methods will extend CO2 measurement coverage in time, space, and perhaps precision such that the underlying mechanisms for carbon exchange at the surface can be understood with .sufficient detail to confidently project the future of carbon-climate interaction and the influence of remediative policy actions. The recent Decadal Survey for Earth Science by the US National Research Council has recommended such a mission called the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) for launch in 2013-2016. We have been developing a laser technique for measurement of tropospheric CO2 for a number of years. Our immediate goal is to develop and demonstrate the method and instrument technology that will permit measurements of the CO2 column abundance over a horizontal path and from aircraft at the few-ppmv level. Our longer-term goal is to demonstrate the required capabilities of the technique, develop a space mission approach, and design the instrument for an ASCENDS-type mission. Our approach is to use a dual channel laser absorption spectrometer (i.e., differential absorption in altimeter mode), which continuously measures from a near-polar circular orbit. We use several co-aligned tunable fiber laser transmitters allowing simultaneous measurement of the absorption from a CO2 line in the 1570 nm band, O2 extinction in the oxygen A-band (near 765 nm), and aerosol backscatter in the same measurement path. We measure the energy of the laser echoes at nadir reflected from land and water surfaces, day and night. The lasers have spectral widths much narrower than the gas absorption lines and are turned on and off the selected CO2 and O2 lines at kHz rates. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and off-line singnals via the DIAL technique. We used pulsed laser signals, photon counting detectors, and time gating to isolate the laser returns from the surface, and to reject photons scattered from thin clouds and aerosols. High signal-to-noise ratios are required and the CO2 estimates can be sensitive to small drifts or other errors in the instrument, so the absorption estimates need to be quite stable for hours. We have constructed a breadboard version of the CO2 sensor that uses a low power fiber laser and a 20 cm diameter telescope. We have used it to make measurements of CO2 absorption in the laboratory and over 200-m to 2-km long open horizontal paths. These have been done in several sessions extending over multiple days, which allows us to assess the measurement stability and to compare absorption variations to readings from an external in situ CO2 sensor. We have also calculated characteristics of the technique for space including its expected measurement performance for different modulation types, and have performed an initial space mission accommodation study. We sill describe these results in the presentation.
Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress
NASA Technical Reports Server (NTRS)
Abshire, J. B.; Krainak, M.; Riris, H. J.; Sun, X.; Riris, H.; Andrews, A. E.; Collatz, J.
2004-01-01
We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.
Widely tunable quantum cascade laser-based terahertz source.
Danylov, Andriy A; Light, Alexander R; Waldman, Jerry; Erickson, Neal; Qian, Xifeng
2014-07-10
A compact, tunable, ultranarrowband terahertz source, Δν∼1 MHz, is demonstrated by upconversion of a 2.324 THz, free-running quantum cascade laser with a THz Schottky-diode-balanced mixer using a swept, synthesized microwave source to drive the nonlinearity. Continuously tunable radiation of 1 μW power is demonstrated in two frequency regions: ν(Laser) ± 0 to 50 GHz and ν(Laser) ± 70 to 115 GHz. The sideband spectra were characterized with a Fourier-transform spectrometer, and the radiation was tuned through CO, HDO, and D2O rotational transitions.
NASA Astrophysics Data System (ADS)
Webber, Michael E.; Claps, Ricardo; Englich, Florian V.; Tittel, Frank K.; Jeffries, Jay B.; Hanson, Ronald K.
2001-08-01
Measurements of NH3 and CO2 were made in bioreactor vent gases with distributed-feedback diode-laser sensors operating near 2 m. Calculated spectra of NH3 and CO2 were used to determine the optimum transitions for interrogating with an absorption sensor. For ammonia, a strong and isolated absorption transition at 5016.977 cm-1 was selected for trace gas monitoring. For CO2 , an isolated transition at 5007.787 cm-1 was selected to measure widely varying concentrations [500 parts per million (ppm) to 10% ,] with sufficient signal for low mole fractions and without being optically thick for high mole fractions. Using direct absorption and a 36-m total path-length multipass flow-through cell, we achieved a minimum detectivity of 0.25 ppm for NH3 and 40 ppm for CO2 . We report on the quasi-continuous field measurements of NH3 and CO2 concentration in bioreactor vent gases that were recorded at NASA Johnson Space Center with a portable and automated sensor system over a 45-h data collection window.
Effectiveness of CO2 laser with subcision in patients with acne scars.
Anupama, Y G; Wahab, Afthab Jameela
2016-11-01
Post-acne facial scarring has always been a challenge to treat. It requires multiple therapeutic modalities as single modality is not hundred percent effective. Therefore, we have combined CO 2 laser resurfacing with subcision in patients with acne scars for better results. The aim is to study the effectiveness and side effects of CO 2 laser with subcision in patients with atrophic acne scars. Fifty patients were selected for the study. Baseline grading was done with Goodman and Baron grading system. Twenty-five patients were randomly selected for subcision followed by CO 2 laser and the remaining patients were selected for CO 2 laser alone. The treatment was done for four sessions at 4-week interval. Clinical photographs were obtained for evaluation. CO 2 laser with subcision showed excellent response in grade-2 and -3 acne scars. Statistically there is a significant difference between CO 2 laser following subcision and CO 2 laser alone at 5% level (p < 0.05). Both procedures were well tolerated with minimal side effects. The highly versatile CO 2 laser is useful for treating acne scars. Subcision prior to the CO 2 laser procedure showed better improvement when compared to CO 2 laser alone. Thus, in acne scars, multiple therapeutic modalities achieve better results.
Lobel, B; Eyal, O; Kariv, N; Katzir, A
2000-01-01
Laser welding of tissues is a method of closure of surgical incisions that, in principle, may have advantages over conventional closure methods. It is a noncontact technique that introduces no foreign body, the closure is continuous and watertight, and the procedure is faster and requires less skill to master. However, in practice, there have been difficulties in obtaining strong and reliable welding. We assumed that the quality of the weld depends on the ability to monitor and control the surface temperature of the welded zone during the procedure. Our objective was to develop a "smart" fiberoptic laser system for controlled temperature welding. We have developed a welding system based on a CO(2) laser and on infrared transmitting AgClBr fibers. This fiberoptic system plays a double role: transmitting laser power for tissue heating and noncontact (radiometric) temperature monitoring and control. The "true" temperature of the heated tissue was determined by using an improved calibration method. We carried out long-studies of CO(2) laser welding of urinary bladders in various animal models. Cystotomies were performed on the animals, and complete closure of the bladder was obtained with a surface temperature of 55 +/- 5 degrees C at the welding site. In early experiments on 31 rats, the success rate was 73%. In later experiments with 10 rabbits and 3 cats, there was an 80% and a 100% success rate, respectively. The success rate in these preliminary experiments and the quality of the weld, as determined histologically, demonstrate that temperature controlled CO(2) laser welding can produce effective welding of tissues. The fiberoptic system can be adapted for endoscopic laser welding. Copyright 2000 Wiley-Liss, Inc.
Growth dynamics of carbon-metal particles and nanotubes synthesized by CO2 laser vaporization
NASA Astrophysics Data System (ADS)
Kokai, F.; Takahashi, K.; Yudasaka, M.; Iijima, S.
To study the growth of carbon-Co/Ni particles and single-wall carbon nanotubes (SWNTs) by 20 ms CO2 laser-pulse irradiation of a graphite-Co/Ni (1.2 at.%) target in an Ar gas atmosphere (600 Torr), we used emission imaging spectroscopy and shadowgraphy with a temporal resolution of 1.67 ms. Wavelength-selected emission images showed that C2 emission was strong in the region close to the target (within 2 cm), while for the same region the blackbody radiation from the large clusters or particles increased with increasing distance from the target. Shadowgraph images showed that the viscous flow of carbon and metal species formed a mushroom or a turbulent cloud spreading slowly into the Ar atmosphere, indicating that particles and SWNTs continued to grow as the ejected material cooled. In addition, emission imaging spectroscopy at 1200 °C showed that C2 and hot clusters and particles with higher emission intensities were distributed over much wider areas. We discuss the growth dynamics of the particles and SWNTs through the interaction of the ambient Ar with the carbon and metal species released from the target by the laser pulse.
Quantum cascade laser based sensor for open path measurement of atmospheric trace gases
NASA Astrophysics Data System (ADS)
Deng, Hao; Sun, Juan; Liu, Ningwu; Ding, Junya; Chao, Zhou; Zhang, Lei; Li, Jingsong
2017-02-01
A sensitive open-path gas sensor employing a continuous-wave (CW) distributed feedback (DFB) quantum cascade laser (QCL) and direct absorption spectroscopy (DAS) was demonstrated for simultaneously measurements of atmospheric CO and N2O. Two interference free absorption lines located at 2190.0175 cm-1 and 2190.3498 cm-1 were selected for CO and N2O concentration measurements, respectively. The Allan variance analysis technique was performed to investigate the long-term performance of the QCL sensor system. The results indicate that a detection limit of 9.92 ppb for CO and 7.7 ppb for N2O with 1-s integration time were achieved, which can be further improved to 1.5 ppb and 1.1 ppb by increasing the average time up to 80 s.
Takizawa, T
1984-01-01
The author started in 1969 his studies on developing the practical models of the carbon dioxide laser surgical units and produced Medilaser-S, Model MEL-42 and MEL-444. By the end of 1982 the author had operated on 143 cases of brain tumour with the laser. Most of those cases were brain tumours which were difficult or impossible to remove by conventional means. The major points of this paper are as follows: The principle of the laser, the mechanism of the CO2 laser, the biomedical features of the CO2 laser, the advantages and disadvantages of the CO2 laser, indications and contraindications for the use of the CO2 laser, development of the CO2 laser surgical units, surgical procedures and techniques of brain tumour laser surgery, adjuvant methods of laser surgery and comparison between the CO2 laser and the Nd-YAG laser.
NASA Technical Reports Server (NTRS)
Johnson, Barry
1992-01-01
The topics covered include the following: (1) CO2 laser kinetics modeling; (2) gas lifetimes in pulsed CO2 lasers; (3) frequency chirp and laser pulse spectral analysis; (4) LAWS A' Design Study; and (5) discharge circuit components for LAWS. The appendices include LAWS Memos, computer modeling of pulsed CO2 lasers for lidar applications, discharge circuit considerations for pulsed CO2 lidars, and presentation made at the Code RC Review.
Investigation of SOI Raman Lasers for Mid-Infrared Gas Sensing
Passaro, Vittorio M.N.; De Leonardis, Francesco
2009-01-01
In this paper, the investigation and detailed modeling of a cascaded Raman laser, operating in the midwave infrared region, is described. The device is based on silicon-on-insulator optical waveguides and a coupled resonant microcavity. Theoretical results are compared with recent experiments, demonstrating a very good agreement. Design criteria are derived for cascaded Raman lasers working as continuous wave light sources to simultaneously sense two types of gases, namely C2H6 and CO2, at a moderate power level of 130 mW. PMID:22408481
Temperature measurement using ultraviolet laser absorption of carbon dioxide behind shock waves.
Oehlschlaeger, Matthew A; Davidson, David F; Jeffries, Jay B
2005-11-01
A diagnostic for microsecond time-resolved temperature measurements behind shock waves, using ultraviolet laser absorption of vibrationally hot carbon dioxide, is demonstrated. Continuous-wave laser radiation at 244 and 266 nm was employed to probe the spectrally smooth CO2 ultraviolet absorption, and an absorbance ratio technique was used to determine temperature. Measurements behind shock waves in both nonreacting and reacting (ignition) systems were made, and comparisons with isentropic and constant-volume calculations are reported.
Performance of alumina-supported Pt catalysts in an electron-beam-sustained CO2 laser amplifier
NASA Technical Reports Server (NTRS)
Cunningham, D. L.; Jones, P. L.; Miyake, C. I.; Moody, S. E.
1990-01-01
The performance of an alumina-supported Pt catalyst system used to maintain the gas purity in an electron-beam-sustained (636) isotope CO2 laser amplifier has been tested. The system characteristics using the two-zone, parallel flow reactor were determined for both continuous- and end-of-day reactor operation using on-line mass spectrometric sampling. The laser amplifier was run with an energy loading of typically 110 J-l/atm and an electron-beam current of 4 mA/sq cm. With these conditions and a pulse repetition frequency of 10 Hz for up to 10,000 shots, increases on the order of 100 ppm O2 were observed with the purifier on and 150 ppm with it off. The 1/e time recovery time was found to be approximately 75 minutes.
Pieralli, Annalisa; Bianchi, Claudia; Longinotti, Manuela; Corioni, Serena; Auzzi, Noemi; Becorpi, Angelamaria; Fallani, Maria Grazia; Cariti, Giuseppe; Petraglia, Felice
2017-11-01
The aim of this study was to evaluate long-term effects of the fractional CO 2 laser for the treatment of vulvovaginal atrophy (VVA) symptoms. Women presenting with VVA symptoms and meeting inclusion criterion were enrolled to fractioned CO 2 laser therapy. Patient's satisfaction was measured on five-point Likert scale at 4 weeks and 6, 12, 18, 24 months after treatment by interview and clinical examination for vaginal livability. 184 patients constituted the final study group: 128 women were spontaneous menopause and 56 were oncological menopause. 117 women were nulliparous and 36 had previous hysterectomy. 95.4% (172/184) of the patients declared that they were satisfied or very satisfied with the procedure at 4 weeks after treatment. At 6 months 92% (170/184) patients were satisfied; at 12 months 72% (118/162) were satisfied; at 18 months 63% (60/94) were satisfied; at 24 months 25% (4/16) of patients answered they were still satisfied. We observed a decline in patient's satisfaction between 18 and 24 months after laser therapy. Data showed that the time interval from onset of menopause was a statistically significant factor (p < 0.05) for treatment satisfaction in oncological group. Long-term data showed that the improvement of vaginal health may continue up to 24 months after fractional CO 2 laser treatment although between 18 and 24 months benefits decline, and approximately 80% of women decide to start a new treatment cycle of laser applications.
NASA Astrophysics Data System (ADS)
Kumar, Manoj; Khare, Jai; Nath, A. K.
2007-02-01
Selective laser isotope separation by TEA CO 2 laser often needs short tail-free pulses. Using laser mixtures having very little nitrogen almost tail free laser pulses can be generated. The laser pulse characteristics and its gas lifetime is an important issue for long-term laser operation. Boltzmann transport equation is therefore solved numerically for TEA CO 2 laser gas mixtures having very little nitrogen to predict electron energy distribution function (EEDF). The distribution function is used to calculate various excitation and dissociation rate of CO 2 to predict laser pulse characteristics and laser gas lifetime, respectively. Laser rate equations have been solved with the calculated excitation rates for numerically evaluated discharge current and voltage profiles to calculate laser pulse shape. The calculated laser pulse shape and duration are in good agreement with the measured laser characteristics. The gas lifetime is estimated by integrating the equation governing the dissociation of CO 2. An experimental study of gas lifetime was carried out using quadrapole mass analyzer for such mixtures to estimate the O 2 being produced due to dissociation of CO 2 in the pulse discharge. The theoretically calculated O 2 concentration in the laser gas mixture matches with experimentally observed value. In the present TEA CO 2 laser system, for stable discharge the O 2 concentration should be below 0.2%.
Bibliography of Soviet Laser Developments, Number 39, January - February 1979.
1979-11-01
with quantum size effects in the active layers , produced by a continuous (300 K) gas-transport epi- taxy method from metalloorganic compounds. ZhTF P...Chirikov (0). Efficient waveguide CO2 laser. ZhTF P, no. 1, 1979, 25-28. 62. Gordiyets, B.F., A.I. Gudzenko, and V.Ya. Panchenko (1,2). Solar -pumped...p. (RZhF, 2/79, 2D1412) 266. Belanov, A.S., Ye.M. Dianov, and A.M. Prokhorov (1). Data tcansmission over quasi-single-mode three- layer optical
Development of a Dual-Laser Digital Holography Diagnostic for Surface Characterization at ORNL
NASA Astrophysics Data System (ADS)
Sawyer, J. C.; Biewer, T. M.; Thomas, C. E.; Zhang, Z.
2017-10-01
The Fusion and Materials for Nuclear Systems Division (FMNSD) at Oak Ridge National Laboratory (ORNL), in collaboration with The University of Tennessee, Knoxville and Third Dimension Technologies (TDT), presents continuing progress towards the development of a dual-laser digital holography (DH) technique for 3D imaging of plasma facing component (PFC) surfaces in real time. This update includes results from an ``on the bench'' single-laser DH demonstration. The dual-laser approach utilizes two CO2 lasers tuned to neighboring molecular CO2 lines to extend the 2 π ambiguity of holographic interferograms to 5 mm from the 10 μm wavelength. Reconstruction of the interferogram allows for measurement of changes in surface topology at rates of 2 mm/s. This status of a dual-laser DH system ``on the bench,'' demonstration and implementation on the Proto-MPEX device will be presented. This work was supported by The University of Tennessee JDRD program and the US. D.O.E. contract DE-AC05-00OR22725. Research sponsored by the Laboratory Directed Research and Development Program of ORNL, managed by UT Battelle, LLC, for the U.S. D.O.E.
NASA Astrophysics Data System (ADS)
Crawford, Danielle R.; Parrish, Milton E.; Gee, Diane L.; Harward, Charles N.
2007-05-01
The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO 2 as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1 s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO 2 intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO 2 deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.
Crawford, Danielle R; Parrish, Milton E; Gee, Diane L; Harward, Charles N
2007-05-01
The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO(2) intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO(2) deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.
Measurement of heat pump processes induced by laser radiation
NASA Technical Reports Server (NTRS)
Garbuny, M.; Henningsen, T.
1983-01-01
A series of experiments was performed in which a suitably tuned CO2 laser, frequency doubled by a Tl3AsSe37 crystal, was brought into resonance with a P-line or two R-lines in the fundamental vibration spectrum of CO. Cooling or heating produced by absorption in CO was measured in a gas-thermometer arrangement. P-line cooling and R-line heating could be demonstrated, measured, and compared. The experiments were continued with CO mixed with N2 added in partial pressures from 9 to 200 Torr. It was found that an efficient collisional resonance energy transfer from CO to N2 existed which increased the cooling effects by one to two orders of magnitude over those in pure CO. Temperature reductions in the order of tens of degrees Kelvin were obtained by a single pulse in the core of the irradiated volume. These measurements followed predicted values rather closely, and it is expected that increase of pulse energies and durations will enhance the heat pump effects. The experiments confirm the feasibility of quasi-isentropic engines which convert laser power into work without the need for heat rejection. Of more immediate potential interest is the possibility of remotely powered heat pumps for cryogenic use, such applications are discussed to the extent possible at the present stage.
Real-time breath gas analysis of CO and CO2 using an EC-QCL
NASA Astrophysics Data System (ADS)
Ghorbani, Ramin; Schmidt, Florian M.
2017-05-01
Real-time breath gas analysis is a promising, non-invasive tool in medical diagnostics, and well-suited to investigate the physiology of carbon monoxide (CO), a potential biomarker for oxidative stress and respiratory diseases. A sensor for precise, breath-cycle resolved, simultaneous detection of exhaled CO (eCO) and carbon dioxide (eCO2) was developed based on a continuous wave, external-cavity quantum cascade laser (EC-QCL), a low-volume multi-pass cell and wavelength modulation spectroscopy. The system achieves a noise-equivalent (1σ) sensitivity of 8.5 × 10-8 cm-1 Hz-1/2 and (2σ) detection limits of 9 ± 2 ppbv and 650 ± 7 ppmv at 0.14 s spectrum acquisition time for CO and CO2, respectively. Integration over 15 s yields a precision of 0.6 ppbv for CO. The fact that the eCO2 expirograms measured by capnography and laser spectroscopy have essentially identical shape confirms true real-time detection. It is found that the individual eCO exhalation profiles from healthy non-smokers have a slightly different shape than the eCO2 profiles and exhibit a clear dependence on exhalation flow rate and breath-holding time. Detection of indoor air CO and broadband breath profiling across the 93 cm-1 mode-hop-free tuning range of the EC-QCL are also demonstrated.
NASA Technical Reports Server (NTRS)
Campbell, Joel F.; Prasad, Narasimha S.; Flood, Michael A.
2011-01-01
NASA Langley Research Center is working on a continuous wave (CW) laser based remote sensing scheme for the detection of CO2 and O2 from space based platforms suitable for ACTIVE SENSING OF CO2 EMISSIONS OVER NIGHTS, DAYS, AND SEASONS (ASCENDS) mission. ASCENDS is a future space-based mission to determine the global distribution of sources and sinks of atmospheric carbon dioxide (CO2). A unique, multi-frequency, intensity modulated CW (IMCW) laser absorption spectrometer (LAS) operating at 1.57 micron for CO2 sensing has been developed. Effective aerosol and cloud discrimination techniques are being investigated in order to determine concentration values with accuracies less than 0.3%. In this paper, we discuss the demonstration of a pseudo noise (PN) code based technique for cloud and aerosol discrimination applications. The possibility of using maximum length (ML)-sequences for range and absorption measurements is investigated. A simple model for accomplishing this objective is formulated, Proof-of-concept experiments carried out using SONAR based LIDAR simulator that was built using simple audio hardware provided promising results for extension into optical wavelengths.
In situ laser annealing system for real-time surface kinetic analysis
NASA Astrophysics Data System (ADS)
Wang, Q.; Sun, Y.-M.; Zhao, W.; Campagna, J.; White, J. M.
2002-11-01
For real-time analysis during thermal annealing, a continuous wave CO2 infrared laser was coupled to a surface analysis system equipped for x-ray photoelectron spectroscopy (XPS) and ion scattering spectroscopy (ISS). The laser beam was directed into the vacuum chamber through a ZnSe window to the back side of the sample. With 10 W laser output, the sample temperature reached 563 K. The chamber remained below 10-8 Torr during annealing and allowed XPS and ISS data to be gathered as a function of time at selected temperatures. As a test example, real time Cu2O reduction at 563 K was investigated.
He, Yabai; Kan, Ruifeng; Englich, Florian V; Liu, Wenqing; Orr, Brian J
2010-09-13
The greenhouse-gas molecules CO(2), CH(4), and H(2)O are detected in air within a few ms by a novel cavity-ringdown laser-absorption spectroscopy technique using a rapidly swept optical cavity and multi-wavelength coherent radiation from a set of pre-tuned near-infrared diode lasers. The performance of various types of tunable diode laser, on which this technique depends, is evaluated. Our instrument is both sensitive and compact, as needed for reliable environmental monitoring with high absolute accuracy to detect trace concentrations of greenhouse gases in outdoor air.
Karbe, E; Königsmann, G; Beck, R
1980-01-01
Various laser devices (CO2, CO, Nd: YAG, and holmium: YAG lasers) have been used on pig livers and on dog kidneys for comparison with conventional surgical instruments (electroscalpel, cryoscalpel, and scalpel). CO2 and CO lasers caused the least tissue damage, followed by the holmium laser; severe damage was caused by the Nd: YAG laser. The order was reverse for coagulative effect. The conventional reference instruments showed a weaker hemostatic effect. Surfaces cut by laser healed in four to eight weeks without complications. Remnants of charred tissue in various quantities could still be detected after eight weeks in all cases where CO2, CO, and Nd: YAG lasers had been used. This obviously did not affect scar formation.
Chen, Kee-Hsin; Tam, Ka-Wai; Chen, I-Fan; Huang, Shihping Kevin; Tzeng, Pei-Chuan; Wang, Hsian-Jenn; Chen, Chiehfeng Cliff
2017-08-01
Laser resurfacing is used to minimize wrinkles, solar scars and sequelae of acne. Purpose of the systematic review was to compare resurfacing outcomes of CO 2 laser and erbium: yttrium aluminium garnet (erb:YAG) laser therapies. Medline, Cochrane Library, EMBASE and Google Scholar databases were searched until 9 April 2015 using the following terms: laser, carbon dioxide/CO 2 , facial wrinkles, rhytides and erbium-doped yttrium aluminium garnet/erbium:YAG/Er:YAG. Two-armed controlled split faced studies that compared CO 2 laser and erbium:YAG laser in patients with mild-to-moderate facial wrinkles or rhytides were included. The pooled data in this study and findings of other studies support the greater efficacy with the CO 2 laser in improving facial wrinkles, but the erb:YAG laser was associated with a better complication profile compared with the CO 2 laser. Except one case of hypopigmentation, other complications (i.e., erythema, hyperpigmentation and crusting) and their rates were reported by studies examining both lasers. In general, the CO 2 laser appeared to be more efficacious then the erb:YAG laser in treating facial wrinkles. Both lasers treatments were well tolerated.
NASA Astrophysics Data System (ADS)
Nontapot, Kanokwan
2018-03-01
The carbon dioxide laser (CO2 laser) is one of the most useful and is the highest CW laser at the present. The laser produces infrared light at 10.6 um. Due to its high power, CO2 lasers are usually used in industrial applications such as cutting and welding, or for engraving at less power. CO2 lasers are also used widely in medical applications, such as laser surgery, skin resurfacing, and removing mold, due to water (biological tissue) absorb light at this wavelength very well. CO2 lasers are also used as LIDAR laser source for military range finding applications because of the transparency of the atmosphere to infrared light. Due to the increasing use of CO2 lasers laser in industrial and medical applications in Thailand, the National Institute of Metrology (Thailand) has set up a CO2 laser power calibration system and provide calibration service to customers this year. The service support calibration of medium-level laser power at wavelength of 10.6 um and at power range 100 mW-10W. The design and development of the calibration system will be presented.
'Design of CO-O2 recombination catalysts for closed-cycle CO2 lasers'
NASA Technical Reports Server (NTRS)
Guinn, K.; Goldblum, S.; Noskowski, E.; Herz, R.
1989-01-01
Pulsed CO2 lasers have many applications in aeronautics, space research, weather monitoring and other areas. Full exploitation of the potential of these lasers is hampered by the dissociation of CO2 that occurs during laser operation. The development of closed-cycle CO2 lasers requires active CO-O2 recombination (CO oxidation) catalysts and design methods for implementation of catalysts inside lasers. This paper will discuss the performance criteria and constraints involved in the design of monolith catalyst configurations for use in a closed-cycle laser and will present a design study performed with a computerized design program that had been written. Trade-offs between catalyst activity and dimensions, flow channel dimensions, pressure drop, O2 conversion and other variables will be discussed.
Continuously-Tunable High-Repetition Rate RF-Excited CO2 Waveguide Laser,
1982-07-01
may be transformed to the appropriate level at the laser head, which elimi- nates the ueed for the very high voltage power supply . Several gas lasers...Figure 5.5 is shown a picture of the rack containing the 50 W amplifier (at the bottom) the 40 V power - supply (in the middle) and the eight final-stage...experimentally. Experimentally 40.68 MHz rf-excitation of discharges between parallel plate electrodes with up to 7-8 kW peak rf- power hus been investigated
Sreemany, Arpita; Bera, Melinda Kumar; Sarkar, Anindya
2017-12-30
The elaborate sampling and analytical protocol associated with conventional dual-inlet isotope ratio mass spectrometry has long hindered high-resolution climate studies from biogenic accretionary carbonates. Laser-based on-line systems, in comparison, produce rapid data, but suffer from unresolvable matrix effects. It is, therefore, necessary to resolve these matrix effects to take advantage of the automated laser-based method. Two marine bivalve shells (one aragonite and one calcite) and one fish otolith (aragonite) were first analysed using a CO 2 laser ablation system attached to a continuous flow isotope ratio mass spectrometer under different experimental conditions (different laser power, sample untreated vs vacuum roasted). The shells and the otolith were then micro-drilled and the isotopic compositions of the powders were measured in a dual-inlet isotope ratio mass spectrometer following the conventional acid digestion method. The vacuum-roasted samples (both aragonite and calcite) produced mean isotopic ratios (with a reproducibility of ±0.2 ‰ for both δ 18 O and δ 13 C values) almost identical to the values obtained using the conventional acid digestion method. As the isotopic ratio of the acid digested samples fall within the analytical precision (±0.2 ‰) of the laser ablation system, this suggests the usefulness of the method for studying the biogenic accretionary carbonate matrix. When using laser-based continuous flow isotope ratio mass spectrometry for the high-resolution isotopic measurements of biogenic carbonates, the employment of a vacuum-roasting step will reduce the matrix effect. This method will be of immense help to geologists and sclerochronologists in exploring short-term changes in climatic parameters (e.g. seasonality) in geological times. Copyright © 2017 John Wiley & Sons, Ltd.
Carbon dioxide (CO2) laser third eyelid excision: surgical description and report of 7 cases.
Dees, Dustin D; Knollinger, Amy M; MacLaren, Nicole E
2015-09-01
To describe a novel technique for third eyelid (TEL) excision using a carbon dioxide (CO2) laser. Prospective. The procedure was performed on six canine patients and one feline patient. The laser was set to 6 Watts (W) of power and a linear continuous setting. Forceps were used to elevate the TEL and, with a protective shield covering the cornea, the base was cut and cauterized simultaneously. Minimal to no hemorrhage was observed, and the conjunctiva was left to heal by second intention. Seven patients underwent unilateral surgical TEL excision. All patients had suspected neoplasms affecting either the glandular tissues or conjunctival surfaces of the TEL. Clean surgical margins were achieved in all but one patient. All surgical sites were considered healed by 14 days showing mild-to-moderate conjunctival hyperemia and accumulation of mucoid discharge at the ventronasal fornix. One patient experienced postoperative keratoconjunctivitis sicca. Prolapse of orbital fat was not observed in any patient. Use of CO2 laser appears to be an efficient and effective means for surgical third eyelid removal with excellent postoperative comfort and minimal complications. © 2014 American College of Veterinary Ophthalmologists.
Development of Sesquioxide Ceramic for High Energy Lasers
2015-05-25
CSJ308 , Mutsuno, Atsuta- ku Nagoya 456-0023 Japan 8. PERFORMING ORGANIZATION REPORT NUMBER N/A 9. SPONSORING/MONITORING AGENCY NAME...Labo Co., Ltd.,1-2-19-CSJ308 , Mutsuno, Atsuta- ku ,Nagoya 456-0023,Japan,NA,NA 8. PERFORMING ORGANIZATION REPORT NUMBER N/A 9. SPONSORING/MONITORING...Huang, D. Shen , J. Zhang, H. Chen, Y. Wang, X. Liu, D. Tang, “Room Temperature Continuous-wave Laser Performance of LD Pumped Er:Lu2O3 and Er:Y2O3
Debris-free soft x-ray source with gas-puff target
NASA Astrophysics Data System (ADS)
Ni, Qiliang; Chen, Bo; Gong, Yan; Cao, Jianlin; Lin, Jingquan; Lee, Hongyan
2001-12-01
We have been developing a debris-free laser plasma light source with a gas-puff target system whose nozzle is driven by a piezoelectric crystal membrane. The gas-puff target system can utilize gases such as CO2, O2 or some gas mixture according to different experiments. Therefore, in comparison with soft X-ray source using a metal target, after continuously several-hour laser interaction with gas from the gas-puff target system, no evidences show that the light source can produce debris. The debris-free soft X-ray source is prepared for soft X-ray projection lithography research at State Key Laboratory of Applied Optics. Strong emission from CO2, O2 and Kr plasma is observed.
NASA Astrophysics Data System (ADS)
Dougakiuchi, Tatsuo; Kawada, Yoichi; Takebe, Gen
2018-03-01
We demonstrate the continuous multispectral imaging of surface phonon polaritons (SPhPs) on silicon carbide excited by an external cavity quantum cascade laser using scattering-type scanning near-field optical microscopy. The launched SPhPs were well characterized via the confirmation that the theoretical dispersion relation and measured in-plane wave vectors are in excellent agreement in the entire measurement range. The proposed scheme, which can excite and observe SPhPs with an arbitrary wavelength that effectively covers the spectral gap of CO2 lasers, is expected to be applicable for studies of near-field optics and for various applications based on SPhPs.
A computer program for the design of optimum catalytic monoliths for CO2 lasers
NASA Technical Reports Server (NTRS)
Guinn, K.; Goldblum, S.; Noskowski, E.; Herz, R.
1990-01-01
Pulsed CO2 lasers have many applications in aeronautics, space research, weather monitoring and other areas. Full exploitation of the potential of these lasers is hampered by the dissociation of CO2 that occurs during laser operation. The development of closed-cycle CO2 lasers requires active CO-O2 recombination (CO oxidation) catalysts and design methods for implementation of catalysts inside lasers. The performance criteria and constraints involved in the design of catalyst configurations for use in a closed-cycle laser are discussed, and several design studies performed with a computerized design program that was written are presented. Trade-offs between catalyst activity and dimensions, flow channel dimensions, pressure drop, O2 conversion and other variables are discussed.
Förster, Erik; Bohnert, Patrick; Kraus, Matthias; Kilper, Roland; Müller, Ute; Buchmann, Martin; Brunner, Robert
2016-11-20
This paper presents the conception and implementation of a variable diameter ring-cutting system for a CO2 laser with a working wavelength of 10.6 μm. The laser-cutting system is adapted to an observation zoom microscope for combined use and is applicable for the extraction of small circular areas from polymer films, such as forensic adhesive tapes in a single shot. As an important characteristic for our application, the variable diameter ring-cutting system provides telecentricity in the target area. Ring diameters are continuously tunable between 500 μm and 2 mm. A minimum width of less than 20 μm was found for the ring profile edge. The basic characteristics of the system, including telecentricity, were experimentally evaluated and demonstrated by cutting experiments on different polymer tapes and further exemplary samples.
NASA Technical Reports Server (NTRS)
Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.
2014-01-01
NASA Langley Research Center in collaboration with ITT Exelis have been experimenting with Continuous Wave (CW) laser absorption spectrometer (LAS) as a means of performing atmospheric CO2 column measurements from space to support the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission.Because range resolving Intensity Modulated (IM) CW lidar techniques presented here rely on matched filter correlations, autocorrelation properties without side lobes or other artifacts are highly desirable since the autocorrelation function is critical for the measurements of lidar return powers, laser path lengths, and CO2 column amounts. In this paper modulation techniques are investigated that improve autocorrelation properties. The modulation techniques investigated in this paper include sine waves modulated by maximum length (ML) sequences in various hardware configurations. A CW lidar system using sine waves modulated by ML pseudo random noise codes is described, which uses a time shifting approach to separate channels and make multiple, simultaneous online/offline differential absorption measurements. Unlike the pure ML sequence, this technique is useful in hardware that is band pass filtered as the IM sine wave carrier shifts the main power band. Both amplitude and Phase Shift Keying (PSK) modulated IM carriers are investigated that exibit perfect autocorrelation properties down to one cycle per code bit. In addition, a method is presented to bandwidth limit the ML sequence based on a Gaussian filter implemented in terms of Jacobi theta functions that does not seriously degrade the resolution or introduce side lobes as a means of reducing aliasing and IM carrier bandwidth.
High-Power DFB Diode Laser-Based CO-QEPAS Sensor: Optimization and Performance.
Ma, Yufei; Tong, Yao; He, Ying; Yu, Xin; Tittel, Frank K
2018-01-04
A highly sensitive carbon monoxide (CO) trace gas sensor based on quartz-enhanced photoacoustic spectroscopy (QEPAS) was demonstrated. A high-power distributed feedback (DFB), continuous wave (CW) 2.33 μm diode laser with an 8.8 mW output power was used as the QEPAS excitation source. By optimizing the modulation depth and adding an optimum micro-resonator, compared to a bare quartz tuning fork (QTF), a 10-fold enhancement of the CO-QEPAS signal amplitude was achieved. When water vapor acting as a vibrational transfer catalyst was added to the target gas, the signal was further increased by a factor of ~7. A minimum detection limit (MDL) of 11.2 ppm and a calculated normalized noise equivalent absorption (NNEA) coefficient of 1.8 × 10 -5 cm -1 W/√Hz were obtained for the reported CO-QEPAS sensor.
High-Power DFB Diode Laser-Based CO-QEPAS Sensor: Optimization and Performance
Ma, Yufei; Tong, Yao; He, Ying; Yu, Xin
2018-01-01
A highly sensitive carbon monoxide (CO) trace gas sensor based on quartz-enhanced photoacoustic spectroscopy (QEPAS) was demonstrated. A high-power distributed feedback (DFB), continuous wave (CW) 2.33 μm diode laser with an 8.8 mW output power was used as the QEPAS excitation source. By optimizing the modulation depth and adding an optimum micro-resonator, compared to a bare quartz tuning fork (QTF), a 10-fold enhancement of the CO-QEPAS signal amplitude was achieved. When water vapor acting as a vibrational transfer catalyst was added to the target gas, the signal was further increased by a factor of ~7. A minimum detection limit (MDL) of 11.2 ppm and a calculated normalized noise equivalent absorption (NNEA) coefficient of 1.8 × 10−5 cm−1W/√Hz were obtained for the reported CO-QEPAS sensor. PMID:29300310
NASA Technical Reports Server (NTRS)
Harward, C. N.
1977-01-01
Measurements were performed to determine the pressure and temperature dependence of CFM-12 absorption coefficients for CO2 waveguide laser radiation. The absorption coefficients of CFM-12 for CO2 waveguide laser radiation were found to have no spectral structure within small spectral bandwidths around the CO2 waveguide laser lines in the CO2 spectral band for pressures above 20 torr. All of the absorption coefficients for the CO2 laser lines studied are independent of pressure above 100 torr, except for the P(36) laser CO2 spectral band. The absorption coefficients associated with the P(42) line in the same band showed the greatest change with temperature, and it also has the largest value of all the lines studied.
The effect of CO2 laser treatment on skin tissue.
Baleg, Sana Mohammed Anayb; Bidin, Noriah; Suan, Lau Pik; Ahmad, Muhammad Fakarruddin Sidi; Krishnan, Ganesan; Johari, Abd Rahman; Hamid, Asma
2015-09-01
The aim of this study was to evaluate the effects of multiple pulses on the depth of injury caused by CO2 laser in an in vivo rat model. A 10 600-nm CO2 laser was applied to rat skin, with one side of the rat dorsal skin being exposed, leaving the other side as a control. All of the various laser pulses tested led to gradual loss of epidermal thickness as well as a dramatic increase in thermal damage depth. Collagen coagulation was most effective with ten pulses of CO2 laser, while the strength of irradiated skin tissue increased as the influence of the laser increased. Fundamental laser-skin interaction effects were studied using a CO2 laser. The photodamaged areas obtained from laser interaction were recorded via couple charge device video camera and analyzed via ImageJ software. Photodamage induced by CO2 laser is due to photothermal effects, which involve burning and vaporizing mechanisms to ablate the epidermis layer. The burning area literally expands and penetrates deep into the dermis layer, subsequently causing collagen coagulation. This fundamental study shows in detail the effect of CO2 laser interaction with skin. The CO2 attributed severe burning, producing deep coagulation, and induced strength to treated skin. © 2015 Wiley Periodicals, Inc.
Meesters, Arne A; Nieboer, Marilin J; Kezic, Sanja; de Rie, Menno A; Wolkerstorfer, Albert
2018-05-07
Efficacy of topical anesthetics can be enhanced by pretreatment of the skin with ablative fractional lasers. However, little is known about the role of parameters such as laser modality and laser density settings in this technique. Aims of this study were to compare the efficacy of pretreatment with two different ablative fractional laser modalities, a CO 2 laser and an Er:YAG laser, and to assess the role of laser density in ablative fractional laser assisted topical anesthesia. In each of 15 healthy subjects, four 10 × 10 mm test regions on the back were randomized to pretreatment (70-75 μm ablation depth) with CO 2 laser at 5% density, CO 2 laser at 15% density, Er:YAG laser at 5% density or Er:YAG laser at 15% density. Articaine hydrochloride 40 mg/ml + epinephrine 10 μg/ml solution was applied under occlusion to all four test regions. After 15 minutes, a pass with the CO 2 laser (1,500 μm ablation depth) was administered as pain stimulus to each test region. A reference pain stimulus was given on unanesthetized skin. The main outcome parameter, pain, was scored on a 0-10 visual analogue scale (VAS) after each pain stimulus. Median VAS scores were 1.50 [CO 2 5%], 0.50 [CO 2 15%], 1.50 [Er:YAG 5%], 0.43 [Er:YAG 15%], and 4.50 [unanesthetized reference]. VAS scores for all pretreated test regions were significantly lower compared to the untreated reference region (P < 0.01). We found no significant difference in VAS scores between the CO 2 and the Er:YAG laser pretreated regions. However, VAS scores were significantly lower at 15% density compared to 5% density for both for the CO 2 laser (P < 0.05) and the Er:YAG laser (P < 0.01). Pretreatment with the CO 2 laser was considered slightly more painful than pretreatment with Er:YAG laser by the subjects. Fractional laser assisted topical anesthesia is effective even with very low energy settings and an occlusion time of only 15 minutes. Both the CO 2 laser and the Er:YAG laser can be used to assist topical anesthesia although the CO 2 laser pretreatment is experienced as more painful. In our study settings, using articaine/epinephrine solution and an occlusion time of 15 minutes, a density of 15% was more effective than 5%. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
Roll-to-Roll Nanoforming of Metals Using Laser-Induced Superplasticity.
Goswami, Debkalpa; Munera, Juan C; Pal, Aniket; Sadri, Behnam; Scarpetti, Caio Lui P G; Martinez, Ramses V
2018-05-24
This Letter describes a low-cost, scalable nanomanufacturing process that enables the continuous forming of thin metallic layers with nanoscale accuracy using roll-to-roll, laser-induced superplasticity (R2RLIS). R2RLIS uses a laser shock to induce the ultrahigh-strain-rate deformation of metallic films at room temperature into low-cost polymeric nanomolds, independently of the original grain size of the metal. This simple and inexpensive nanoforming method does not require access to cleanrooms and associated facilities, and can be easily implemented on conventional CO 2 lasers, enabling laser systems commonly used for rapid prototyping or industrial cutting and engraving to fabricate uniform and three-dimensional crystalline metallic nanostructures over large areas. Tuning the laser power during the R2RLIS process enables the control of the aspect ratio and the mechanical and optical properties of the fabricated nanostructures. This roll-to-roll technique successfully fabricates mechanically strengthened gold plasmonic nanostructures with aspect ratios as high as 5 that exhibit high oxidation resistance and strong optical field enhancements. The CO 2 laser used in R2RLIS can also integrate the fabricated nanostructures on transparent flexible substrates with robust interfacial contact. The ability to fabricate ultrasmooth metallic nanostructures using roll-to-roll manufacturing enables the large scale production, at a relatively low-cost, of flexible plasmonic devices toward emerging applications.
Isotope Exchange in Oxide Catalyst
NASA Technical Reports Server (NTRS)
Hess, Robert V.; Miller, Irvin M.; Schryer, David R.; Sidney, Barry D.; Wood, George M., Jr.; Hoyt, Ronald F.; Upchurch, Billy T.; Brown, Kenneth G.
1987-01-01
Replacement technique maintains level of CO2/18 in closed-cycle CO2 lasers. High-energy, pulsed CO2 lasers using rare chemical isotopes must be operated in closed cycles to conserve gas. Rare isotopes operated in closed cycles to conserve gas. Rare isotopes as CO2/18 used for improved transmission of laser beam in atmosphere. To maintain laser power, CO2 must be regenerated, and O2 concentration kept below few tenths of percent. Conditions achieved by recombining CO and O2.
Experimental Investigation of Laser-sustained Plasma in Supersonic Argon Flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sperber, David; Eckel, Hans-Albert; Moessinger, Peter
Laser-induced energy deposition is widely discussed as a flow control technique in supersonic transportation. In case of thermal laser-plasma upstream of a blunt body, a substantial adaptation of shock wave geometry and magnitude of wave drag is predicted. Related to the research on laser supported detonation, the paper describes the implementation of laser-sustained plasma in a supersonic Argon jet. The stable plasma state is generated by the intersection of a Q-switched Nd:YAG-laser and a continuous wave CO{sub 2}-laser beams, for ignition and maintenance of the plasma respectively. A miniature supersonic Ludwieg tube test facility generates a supersonic jet at velocitiesmore » of Mach 2.1. Modifications of the flow and plasma conditions are investigated and characterized by Schlieren flow visualisation, laser energy transmission and plasma radiation measurements. The results include the discussions of the flow field as well as the required laser and gas parameters.« less
CO2 laser drives extreme ultraviolet nano-lithography — second life of mature laser technology
NASA Astrophysics Data System (ADS)
Nowak, K. M.; Ohta, T.; Suganuma, T.; Fujimoto, J.; Mizoguchi, H.; Sumitani, A.; Endo, A.
2013-12-01
It was shown both theoretically and experimentally that nanosecond order laser pulses at 10.6 micron wavelength were superior for driving the Sn plasma extreme ultraviolet (EUV) source for nano-lithography for the reasons of higher conversion efficiency, lower production of debris and higher average power levels obtainable in CO2 media without serious problems of beam distortions and nonlinear effects occurring in competing solid-state lasers at high intensities. The renewed interest in such pulse format, wavelength, repetition rates in excess of 50 kHz and average power levels in excess of 18 kiloWatt has sparked new opportunities for a matured multi-kiloWatt CO2 laser technology. The power demand of EUV source could be only satisfied by a Master-Oscillator-Power-Amplifier system configuration, leading to a development of a new type of hybrid pulsed CO2 laser employing a whole spectrum of CO2 technology, such as fast flow systems and diffusion-cooled planar waveguide lasers, and relatively recent quantum cascade lasers. In this paper we review briefly the history of relevant pulsed CO2 laser technology and the requirements for multi-kiloWatt CO2 laser, intended for the laser-produced plasma EUV source, and present our recent advances, such as novel solid-state seeded master oscillator and efficient multi-pass amplifiers built on planar waveguide CO2 lasers.
Routine use of the CO2 laser technique for resection of cerebral tumours.
Deruty, R; Pelissou-Guyotat, I; Mottolese, C; Amat, D
1993-01-01
The CO2 laser technique has been routinely used from 1988 through 1992 for the resection of 93 cerebral tumours (meningiomas 58%, gliomas 15%, neurinomas 9%, miscellaneous 18%). The CO2 laser technique was found the more effective 1) in tumours of hard consistency, 2) in large or giant tumours, 3) in tumours with scarce vascularization. Meningiomas were the indication of choice (54 cases that is 58% of all tumours treated with CO2 laser, and 64% of all meningiomas operated on during the same period). Among the meningiomas treated with the CO2 laser, 54% were located on the skull base. The CO2 laser beam provides good haemostasis of small vessels during the vaporization process. When attached to the operative microscope, the other advantages of the CO2 laser technique are: the absence of a handle-piece, the absence of manual manipulation of the tumour, the coaxiality of the laser beam with the visual beam. The disadvantages are: the rigidity of the coupled microscope-Laser arm, the smoke produced by the vaporization of hard tumours, the noise of the device.
Esmat, Samia M; Elramly, Amany Z; Abdel Halim, Dalia M; Gawdat, Heba I; Taha, Hanaa I
2014-12-01
Xanthelasma palpebrarum (XP) is a common cosmetic concern. Although there is a wide range of therapeutic modalities for XP, there is no general consensus on the optimal treatment for such condition. Compare the efficacy and safety of super pulsed (SP) and fractional CO2 lasers in the treatment of XP. This prospective randomized comparative clinical study included 20 adult patients with bilateral and symmetrical XP lesions. Xanthelasma palpebrarum lesions were randomly assigned to treatment by either single session of ablative SP CO2 laser or 3 to 5 sessions of ablative fractional CO2 laser with monthly intervals. All patients were assessed using digital photography and optical coherence tomography images. Xanthelasma palpebrarum lesions on both sides were successfully removed with significant improvement in size, color, and thickness. Although lesions treated by SP CO2 laser showed significantly better improvement regarding color and thickness of the lesions, downtime and patient satisfaction were significantly better for lesions treated with fractional CO2 laser. Scarring and recurrence were significantly higher in lesions treated by SP CO2 laser. Ablative fractional CO2 laser is an effective and safe therapeutic option for XP with significantly shorter downtime and higher patient satisfaction compared with SP CO2 laser.
Study, optimization, and design of a laser heat engine
NASA Technical Reports Server (NTRS)
1978-01-01
Laser heat engine concepts, proposed for satellite applications, were analyzed to determine which engine concepts best meet the requirements of high efficiency (50 percent or better) continuous operation in space. The best laser heat engine for a near-term experimental demonstration, selected on the basis of high overall operating efficiency, high power-to-weight characteristics, and availability of the required technology, is an Otto/Diesel cycle piston engine using a diamond window to admit CO2 laser radiation. The technology with the greatest promise of scaling to megawatt power levels in the long term is the energy exchanger/gas turbine combination.
Flash scanning the CO2 laser: a revival of the CO2 laser in plastic surgery
NASA Astrophysics Data System (ADS)
Lach, Elliot
1994-09-01
The CO2 laser has broad clinical application yet also presents a number of practical disadvantages. These drawbacks have limited the success and utilization of this laser in plastic surgery. Flashscanner technology has recently been used for char-free CO2 laser surgery of the oropharynx, the external female genital tract, and perirectal mucosa. A commercially available optomechanical flashscanner unit `Swiftlase,' was adapted to a CO2 laser and used for treatment in numerous plastic surgical applications. Conditions and situations that were treated in this study included generalized neurofibromatosis, tuberous sclerosis, rhinophyma, viral warts, breast reconstruction, and deepithelialization prior to microsurgery or local flap transfer and/or skin graft placement. There were no significant wound healing complications. Some patients previously sustained undue scarring from conventional CO2 laser surgery. Conservative, primarily ablative CO2 laser surgery with the Swiftlase has usefulness for treatment of patients in plastic surgery including those that were previously unsuccessfully treated.
Catalytic Oxidation of CO for Closed-Cycle CO2 Lasers
NASA Technical Reports Server (NTRS)
Miller, I. M.; Schryer, D. R.; Hess, R. V.; Sidney, B. D.; Wood, G. M., Jr.; Paulin, P. A.; Upchurch, B. T.; Brown, K. G.
1987-01-01
Stoichiometric mixture converted completely. High-energy pulsed CO2 lasers have potential for measuring many different features of atmosphere of Earth and particularly useful on airborne or space platforms. For this application, laser must be operated in closed cycle to conserve gas, especially if rare nonradioactive isotopes of carbon and oxygen used. However, laser discharge decomposes fraction of CO2 to CO and O2, causing rapid loss in power leading to erratic behavior. To maintain operation, CO and O2 must be recombined to form CO2.
Bladder welding in rats using controlled temperature CO2 laser system.
Lobik, L; Ravid, A; Nissenkorn, I; Kariv, N; Bernheim, J; Katzir, A
1999-05-01
Laser tissue welding has potential advantages over conventional suture closure of surgical wounds. It is a noncontact technique that introduces no foreign body and limits the possibility of infections and complications. The closure could be immediately watertight and the procedure may be less traumatic, faster and easier. In spite of these positives laser welding has not yet been approved for wide use. The problem in the clinical implementation of this technique arises from the difficulty in defining the conditions under which a highly reliable weld is formed. We have assumed that the successful welding of tissues depends on the ability to monitor and control the surface temperature during the procedure, thereby avoiding underheating or overheating. The purpose of this work was to develop a laser system for reliable welding of urinary tract tissues under good temperature control. We have developed a "smart" laser system that is capable of a dual role: transmitting CO2 laser power for tissue heating, and noncontact (radiometric) temperature monitoring and control. Bladder opening (cystotomy) was performed in 38 rats. Thirty-three animals underwent laser welding. In 5 rats (control group) the bladder wound was closed with one layer of continuous 6-0 dexon sutures. Reliable welding was obtained when the surface temperature was kept at 71 + 5C. Quality of weld was controlled immediately after operation. The rats were sacrificed on days 2, 10 and 30 for histological study. Bladder closure using the laser welding system was successful in 31/33 (94%) animals. Histological examination revealed an excellent welding and healing of the tissue. Efficiency of laser welding of urinary bladder in rats was confirmed by high survival rate and quality of scar that was demonstrated by clinical and histological examinations. In the future, optimal laser welding conditions will be studied in larger animals, using CO2 lasers and other lasers, with deeper radiation penetration into tissues.
Study on coal char ignition by radiant heat flux.
NASA Astrophysics Data System (ADS)
Korotkikh, A. G.; Slyusarskiy, K. V.
2017-11-01
The study on coal char ignition by CO2-continuous laser was carried out. The coal char samples of T-grade bituminous coal and 2B-grade lignite were studied via CO2-laser ignition setup. Ignition delay times were determined at ambient condition in heat flux density range 90-200 W/cm2. The average ignition delay time value for lignite samples were 2 times lower while this difference is larger in high heat flux region and lower in low heat flux region. The kinetic constants for overall oxidation reaction were determined using analytic solution of simplified one-dimensional heat transfer equation with radiant heat transfer boundary condition. The activation energy for lignite char was found to be less than it is for bituminous coal char by approximately 20 %.
Active optical CO2 sensing for Ground-based, Airborne, and from Space platform
NASA Astrophysics Data System (ADS)
Sakaizawa, D.; Kawakami, S.; Nakajima, M.; Tanaka, T.; Miyamoto, Y.; Inoue, M.; Morino, I.; Uchino, O.; Sawa, Y.; Matsueda, H.
2011-12-01
Accurate measurements of lower tropospheric CO2 from space are strongly needed to quantify processes that identify the CO2 flux by the lands and oceans. The Greenhouse gases Observing SATellite (GOSAT) is the first space mission focused on lower tropospheric CO2 measurements by detecting the near-infrared spectral absorption in reflected sunlight. The GOSAT mission is a key first step, and will increase knowledge about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurements approach, 1) the best performance of CO2 total column measurements can only be performed under the clear-sky atmosphere, 2) seasonal dependence reduces its global coverage, such as the case of the northern hemisphere in winter, and 3) unknowns and variations in cloud and aerosol contamination is also sensitive for CO2 measurements. The laser-based CO2 remote sensing is advantage of those un-met needs. We have developed and improved a compact differential laser absorption sensor (LAS) for measuring the weighted column-averaged dry CO2 mixing ratio (Wq) as a candidate for space mission. Our instrument employs two continuous-wave lasers and a fiber amplifier, which are available of simultaneous measurements of CO2 differential absorption optical depth and range to the target. The amplitude-modulated laser outputs are amplified by a fiber-amplifier. The receiver uses a compact telescope and photodiodes, and measures the laser powers reflected from the target. The gas absorption and column-averaged mixing ratio for the CO2 are evaluated from the ratio of the on- and off-line signals. We have performed ground-based and airborne measurement to evaluate uncertainty of Wq measurements. In these measurements R(12) line in the (30012<-00001) absorption bands of 12C16O2 was used. The precision of the ground-based measurements of horizontal Wq was 0.49% for a horizontal range of 2.1 km. The first airborne measurements were also made during August 2009. These measurements were made over grasslands from 0.5-7 km altitude. There results were compared with airborne flask sampling data and confirmed same trends along height. In February 2010 and February 2011 we made a total of 6 flights and also measured the vertical Wq over the urban area. A high correlation coefficient of 0.99 was obtained between Wq observed by LAS and that calculated by airborne in-situ measurement. More details about measurements and analysis will be presented in the meeting.
González-Mosquera, A; Seoane, J; García-Caballero, L; López-Jornet, P; García-Caballero, T; Varela-Centelles, P
2012-09-01
Our aim was to assess wounds made by lasers (CO(2) and Er,Cr:YSGG) for their epithelial architectural changes and width of damage. We allocated 60 Sprague-Dawley(®) rats into groups: glossectomy by CO(2) laser at 3 different wattages (n=10 in each); glossectomy by Er,Cr:YSGG laser at two different emissions (n=10 in each), and a control group (n=10). Histological examination assessed both prevalence and site of thermal artefacts for each group. Both lasers (CO(2) and Er,Cr:YSGG) caused the same type of cytological artefacts. The 3W Er,Cr:YSGG laser produced the fewest cytological artefacts/specimen, and was significantly different from the other experimental groups: 3W CO(2) laser (95% CI=0.8 to 1.0); the 6W CO(2) laser (95% CI=0.1 to 2.0) and the 10W CO(2) laser (95% CI=1.1 to 3.0). CO(2) lasers (3-10W) generate epithelial damage that can simulate dysplastic changes with cytological atypia that affects mainly the basal and suprabasal layers. Irradiation with Er,CR:YSGG laser (2-4W) produces significantly fewer cellular artefacts and less epithelial damage, which may be potentially useful for biopsy of oral mucosa. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
de Oliveira, Guilherme Bueno; Antonio, João Roberto; Antonio, Carlos Roberto; Tomé, Fernanda Alves
2015-01-01
BACKGROUND Onychomycosis is a fungal infection of the nails caused in most cases by dermatophytes Trichophyton rubrum and Trichophyton mentagrophytes. Despite numerous available antifungal drugs for therapy of this infection, the cure rate is low, with high rates of relapse after treatment and side effects. OBJECTIVES To present a new option for the treatment of onychomycosis, in search of a more effective and rapid method than conventional ones. METHODS Patients underwent two sessions of CO2 fractional laser 10.600nm associated with photodynamic therapy. Mycological and digital photography were performed before and after the treatment. RESULTS McNemar test with continuity correction and degrees of freedom = 1: for clinical cure rate, 13.06, with p=0.00005; for mycological cure, 17.05, with p=0.00005; 72% felt fully satisfied with the procedure. CONCLUSIONS The use of fractional CO2 laser 10.600nm associated with photodynamic therapy can be effective in the treatment of onychomycosis, decreasing the risk of systemic lesions that may be triggered with prolonged use of oral antifungals. PMID:26375214
DOE Office of Scientific and Technical Information (OSTI.GOV)
Golyshev, A A; Malikov, A G; Orishich, A M
Processes of cutting stainless steel by ytterbium fibre and CO{sub 2} lasers have been experimentally compared. The cut surface roughnesses for 3- and 5-mm-thick stainless steel sheets are determined. The absorption coefficient of laser radiation during cutting is measured. It is established that the power absorbed by metal during cutting by the CO{sub 2} laser exceeds that for the ytterbium laser (provided that the cutting speed remains the same). The fact that the maximum cutting speed of the CO{sub 2} laser is lower than that of the ytterbium fibre laser is explained. (laser technologies)
Shingyochi, Yoshiaki; Kanazawa, Shigeyuki; Tajima, Satoshi; Tanaka, Rica; Mizuno, Hiroshi; Tobita, Morikuni
2017-01-01
Background Low-level laser therapy (LLLT) with various types of lasers promotes fibroblast proliferation and migration during the process of wound healing. Although LLLT with a carbon dioxide (CO2) laser was also reported to promote wound healing, the underlying mechanisms at the cellular level have not been previously described. Herein, we investigated the effect of LLLT with a CO2 laser on fibroblast proliferation and migration. Materials and Methods Cultured human dermal fibroblasts were prepared. MTS and cell migration assays were performed with fibroblasts after LLLT with a CO2 laser at various doses (0.1, 0.5, 1.0, 2.0, or 5.0 J/cm2) to observe the effects of LLLT with a CO2 laser on the proliferation and migration of fibroblasts. The non-irradiated group served as the control. Moreover, western blot analysis was performed using fibroblasts after LLLT with a CO2 laser to analyze changes in the activities of Akt, extracellular signal-regulated kinase (ERK), and Jun N-terminal kinase (JNK), which are signaling molecules associated with cell proliferation and migration. Finally, the MTS assay, a cell migration assay, and western blot analysis were performed using fibroblasts treated with inhibitors of Akt, ERK, or JNK before LLLT with a CO2 laser. Results In MTS and cell migration assays, fibroblast proliferation and migration were promoted after LLLT with a CO2 laser at 1.0 J/cm2. Western blot analysis revealed that Akt, ERK, and JNK activities were promoted in fibroblasts after LLLT with a CO2 laser at 1.0 J/cm2. Moreover, inhibition of Akt, ERK, or JNK significantly blocked fibroblast proliferation and migration. Conclusions These findings suggested that LLLT with a CO2 laser would accelerate wound healing by promoting the proliferation and migration of fibroblasts. Activation of Akt, ERK, and JNK was essential for CO2 laser-induced proliferation and migration of fibroblasts. PMID:28045948
NASA Astrophysics Data System (ADS)
Ueno, Yoshifumi; Ariga, Tatsuya; Soumagne, George; Higashiguchi, Takeshi; Kubodera, Shoichi; Pogorelsky, Igor; Pavlishin, Igor; Stolyarov, Daniil; Babzien, Marcus; Kusche, Karl; Yakimenko, Vitaly
2007-05-01
We demonstrated efficacy of a CO2-laser-produced xenon plasma in the extreme ultraviolet (EUV) spectral region at 13.5nm at variable laser pulse widths between 200ps and 25ns. The plasma target was a 30μm liquid xenon microjet. To ensure the optimum coupling of CO2 laser energy with the plasma, they applied a prepulse yttrium aluminum garnet laser. The authors measured the conversion efficiency (CE) of the 13.5nm EUV emission for different pulse widths of the CO2 laser. A maximum CE of 0.6% was obtained for a CO2 laser pulse width of 25ns at an intensity of 5×1010W/cm2.
Gu, Qingjia; Feng, Yong; Yu, Xiaoxu; Fan, Jian'gang; Li, Debing; He, Gang
2014-08-01
To investigate the efficacy of CO2 laser treatment for patients with precancerous laryngeal lesions under phonomicrosurgery and to explore the points for attention in operation. They were all treated with phonomicrosurgery techniques as mucosal epitheliumablation or mucosal stripping by using CO2 laser. Eight patients with laryngeal papilloma were excised by CO2 laser. All patients were treated with CO2 laser surgery successfully. During follow-up of 6 to 39 months, all patients survived. Local recurrence or canceration were detected in 3 cases, of which 2 cases with laryngeal papilloma underwent CO2 laser treatment in one year post-operatively, while the other case with severe dysplasia underwent laryngeal vertical partial laryngectomy and post-operative radiotherapy one and half year postoperatively due to canceration. No local recurrence occurred until the last follow up. No severe complications such as dyspnea and hemorrhage occured. CO2 laser surgery is an effective and minimally invasive treatment for precancerous laryngeal lesions. Through selecting the appropriate patient and paying attention to the operation during surgery, the adhesion of vocal cord can be reduced or even be avoided after CO2 laser surgery.
Roux, F X; Leriche, B; Cioloca, C; Devaux, B; Turak, B; Nohra, G
1992-01-01
The authors present their experience concerning the use of Combolaser (Lasermatic, Finland), in neurosurgery. This laser-unit combines two wavelengths (CO2 and 1.06 Nd-YAG) which are emitted simultaneously and coaxially. During the last 12 months, 40 patients harbouring an intracranial tumor were operated upon with such a combolaser unit: 8 infra-tentorial, 32 supra-tentorial, 17 were meningiomas. The mean output power used during the procedures was 3-5 w for both CO2 and Nd-YAG beams. The authors discuss the advantages and inconveniences of such a laser; and they compare it with the other laser-units they have been using for the last 10 years: CO2-Laser, 1.06 Nd-YAG and 1.32 Nd-YAG laser. The main inconvenience of this unit is linked to the utilization of the articulated arm which conducts the CO2 laser beam. This drawback should be avoided or limited by the use of a fiber microguide, which will conduct both CO2 and Nd-YAG beams simultaneously. The principal contribution of a combined-laser unit is the quality of the haemostasis associated to a very good vaporization and cutting effect. When both wavelengths are synchronized, the combined laser beams penetrate into the nervous parenchyma more deeply than the only CO2 laser beam would with the same parameters. The vaporization effect is identical to that obtained with the isolated CO2 laser; the quality of haemostasis is limited to the effects of the Nd-YAG laser. Another advantage must be emphasized: the possibility of utilizing separately the CO2 laser and the 1.06 Nd-YAG.
A four kHz repetition rate compact TEA CO2 laser
NASA Astrophysics Data System (ADS)
Zheng, Yijun; Tan, Rongqing
2013-09-01
A compact transversely excited atmospheric (TEA) CO2 laser with high repetition-rate was reported. The size of the laser is 380 mm×300 mm×200 mm, and the discharge volume is 12×103 mm3. The laser cavity has a length of 320mm and consists of a totally reflective concave mirror with a radius of curvature of 4 m (Cu metal substrate coated with Au) and a partially reflecting mirror. The ultraviolet preionization makes the discharge even and stable,the output energy can be as high as 28 mJ under the circumstance of free oscillation, and the width of the light pulse is 60ns.To acquire the high wind velocity, a turbocharger is used in the system of the fast-gas flow cycle. When the wind speed is 100m/s, the repetition rate of the transversely excited atmospheric CO2 laser is up to 2 kHz. On this basis, a dual modular structure with two sets of the gas discharge unit is adopted to obtain a higher pulse repetition frequency output. The dual discharge unit composed two sets of electrodes and two sets of turbo fan. Alternate trigger technology is used to make the two sets of discharge module work in turn with repetition frequency of 2 kHz, the discharge interval of two sets of the gas discharge unit can be adjusted continuously from 20 microseconds to 250 microseconds. Under the conditions of maintaining the other parameters constant, the repetition frequency of the laser pulse is up to 4 kHz. The total size of laser with dual modular structure is 380mm×520mm×200mm, and the discharge volume is 24×103 mm3 with the cavity length of 520mm.
Conversion of blackbody radiation into laser energy
NASA Technical Reports Server (NTRS)
Mcinville, R. M.; Hassan, H. A.
1982-01-01
By employing detailed kinetic models, three concepts which utilize a blackbody cavity for the conversion of solar energy into laser energy using a CO2 lasant are analyzed and compared. In the first, the blackbody radiation is used to excite flowing CO2 directly. The second and third employ a mixing laser concept with CO and N2 being the donor gases. The CO is optically pumped while thermal heating excites the N2. Blackbody temperatures ranging from 1500 deg K - 2500 deg K are considered. Based on calculated laser power output per unit flow rate of CO2, it appears that the N2-CO2 mixing laser is the most attractive system.
High temperature infrared absorption cross sections of methane near 3.4 µm in Ar and CO 2 mixtures
Koroglu, Batikan; Neupane, Sneha; Pryor, Owen; ...
2017-11-04
In this study, the absorption cross-sections of CH 4 at two wavelengths in the mid-IR region: λ peak = 3403.4 nm and λ valley = 3403.7 nm were measured. Data were taken using three different compositions of non-reactive gas mixtures comprising CH 4/Ar/CO 2 between 700 < T < 2000 K and 0.1 < P < 1.5 atm in a shock tube utilizing a continuous-wave distributed-feedback quantum cascade laser. Also, broadband room temperature methane cross section measurements were performed using a Fourier transform infrared spectrometer and the cascade laser to gain a better insight into the changes of the linemore » shapes in various bath gasses (Ar, CO 2, and N 2). An application of the high-temperature cross-section data was demonstrated to determine the concentration of methane during oxy-methane combustion in a mixture of CO 2, O 2, and Ar. Lastly, current measurements will be valuable addition to the spectroscopy database for methane- an important fuel used for power generation and heating around the world.« less
High temperature infrared absorption cross sections of methane near 3.4 µm in Ar and CO 2 mixtures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koroglu, Batikan; Neupane, Sneha; Pryor, Owen
In this study, the absorption cross-sections of CH 4 at two wavelengths in the mid-IR region: λ peak = 3403.4 nm and λ valley = 3403.7 nm were measured. Data were taken using three different compositions of non-reactive gas mixtures comprising CH 4/Ar/CO 2 between 700 < T < 2000 K and 0.1 < P < 1.5 atm in a shock tube utilizing a continuous-wave distributed-feedback quantum cascade laser. Also, broadband room temperature methane cross section measurements were performed using a Fourier transform infrared spectrometer and the cascade laser to gain a better insight into the changes of the linemore » shapes in various bath gasses (Ar, CO 2, and N 2). An application of the high-temperature cross-section data was demonstrated to determine the concentration of methane during oxy-methane combustion in a mixture of CO 2, O 2, and Ar. Lastly, current measurements will be valuable addition to the spectroscopy database for methane- an important fuel used for power generation and heating around the world.« less
High temperature infrared absorption cross sections of methane near 3.4 μm in Ar and CO2 mixtures
NASA Astrophysics Data System (ADS)
Koroglu, Batikan; Neupane, Sneha; Pryor, Owen; Peale, Robert E.; Vasu, Subith S.
2018-02-01
The absorption cross-sections of CH4 at two wavelengths in the mid-IR region: λpeak = 3403.4 nm and λvalley = 3403.7 nm were measured. Data were taken using three different compositions of non-reactive gas mixtures comprising CH4/Ar/CO2 between 700 < T < 2000 K and 0.1 < P < 1.5 atm in a shock tube utilizing a continuous-wave distributed-feedback quantum cascade laser. Also, broadband room temperature methane cross section measurements were performed using a Fourier transform infrared spectrometer and the cascade laser to gain a better insight into the changes of the line shapes in various bath gasses (Ar, CO2, and N2). An application of the high-temperature cross-section data was demonstrated to determine the concentration of methane during oxy-methane combustion in a mixture of CO2, O2, and Ar. Current measurements will be valuable addition to the spectroscopy database for methane- an important fuel used for power generation and heating around the world.
Pseudorandom Noise Code-Based Technique for Cloud and Aerosol Discrimination Applications
NASA Technical Reports Server (NTRS)
Campbell, Joel F.; Prasad, Narasimha S.; Flood, Michael A.; Harrison, Fenton Wallace
2011-01-01
NASA Langley Research Center is working on a continuous wave (CW) laser based remote sensing scheme for the detection of CO2 and O2 from space based platforms suitable for ACTIVE SENSING OF CO2 EMISSIONS OVER NIGHTS, DAYS, AND SEASONS (ASCENDS) mission. ASCENDS is a future space-based mission to determine the global distribution of sources and sinks of atmospheric carbon dioxide (CO2). A unique, multi-frequency, intensity modulated CW (IMCW) laser absorption spectrometer (LAS) operating at 1.57 micron for CO2 sensing has been developed. Effective aerosol and cloud discrimination techniques are being investigated in order to determine concentration values with accuracies less than 0.3%. In this paper, we discuss the demonstration of a PN code based technique for cloud and aerosol discrimination applications. The possibility of using maximum length (ML)-sequences for range and absorption measurements is investigated. A simple model for accomplishing this objective is formulated, Proof-of-concept experiments carried out using SONAR based LIDAR simulator that was built using simple audio hardware provided promising results for extension into optical wavelengths. Keywords: ASCENDS, CO2 sensing, O2 sensing, PN codes, CW lidar
Green, H A; Burd, E E; Nishioka, N S; Compton, C C
1993-08-01
Ablative lasers have been used for cutaneous surgery for greater than two decades since they can remove skin and skin lesions bloodlessly and efficiently. Because full-thickness skin wounds created after thermal laser ablation may require skin grafting in order to heal, we have examined the effect of the residual laser-induced thermal damage in the wound bed on subsequent skin graft take and healing. In a pig model, four different pulsed and continuous-wave lasers with varying wavelengths and radiant energy exposures were used to create uniform fascial graft bed thermal damage of approximately 25, 160, 470, and 1100 microns. Meshed split-thickness skin graft take and healing on the thermally damaged fascial graft beds were examined on a gross and microscopic level on days 3 and 7, and then weekly up to 42 days. Laser-induced thermal damage on the graft bed measuring greater than 160 +/- 60 microns in depth significantly decreased skin graft take. Other deleterious effects included delayed graft revascularization, increased inflammatory cell infiltrate at the graft-wound bed interface, and accelerated formation of hypertrophied fibrous tissue within the graft bed and underlying muscle. Ablative lasers developed for cutaneous surgery should create less than 160 +/- 60 microns of residual thermal damage to permit optimal skin graft take and healing. Pulsed carbon dioxide and 193-nm excimer lasers may be valuable instruments for the removal of full-thickness skin, skin lesions, and necrotic tissue, since they create wound beds with minimal thermal damage permitting graft take comparable to that achieved with standard surgical techniques.
Böttcher, Arne; Jowett, Nathan; Kucher, Stanislav; Reimer, Rudolph; Schumacher, Udo; Knecht, Rainald; Wöllmer, Wolfgang; Münscher, Adrian; Dalchow, Carsten V
2014-05-01
Despite causing significant thermocoagulative insult, use of the carbon dioxide (CO2) laser is considered gold standard in surgery for early stage larynx carcinoma. Limited attention has been paid to the use of the erbium:yttrium-aluminium-garnet (Er:YAG) laser in laryngeal surgery as a means to reduce thermal tissue injury. The objective of this study is to compare the extent of thermal injury and precision of vocal fold incisions made using microsecond Er:YAG and superpulsed CO2 lasers. In the optics laboratory ex vivo porcine vocal folds were incised using Er:YAG and CO2 lasers. Lateral epithelial and subepithelial thermal damage zones and cutting gap widths were histologically determined. Environmental scanning electron microscopy (ESEM) images were examined for signs of carbonization. Temperature rise during Er:YAG laser incisions was determined using infrared thermography (IRT). In comparison to the CO2 laser, Er:YAG laser incisions showed significantly decreased epithelial (236.44 μm) and subepithelial (72.91 μm) damage zones (p < 0.001). Cutting gaps were significantly narrower for CO2 (878.72 μm) compared to Er:YAG (1090.78 μm; p = 0.027) laser. ESEM revealed intact collagen fibres along Er:YAG laser cutting edges without obvious carbonization, in comparison to diffuse carbonization and tissue melting seen for CO2 laser incisions. IRT demonstrated absolute temperature rise below 70 °C for Er:YAG laser incisions. This study has demonstrated significantly reduced lateral thermal damage zones with wider basal cutting gaps for vocal fold incisions made using Er:YAG laser in comparison to those made using CO2 laser.
Co-extruded mechanically tunable multilayer elastomer laser
NASA Astrophysics Data System (ADS)
Crescimanno, Michael; Mao, Guilin; Andrews, James; Singer, Kenneth; Baer, Eric; Hiltner, Anne; Song, Hyunmin; Shakya, Bijayandra
2011-04-01
We have fabricated and studied mechanically tunable elastomer dye lasers constructed in large area sheets by a single-step layer-multiplying co-extrusion process. The laser films consist of a central dye-doped (Rhodamine-6G) elastomer layer between two 128-layer distributed Bragg reflector (DBR) films comprised of alternating elastomer layers with different refractive indices. The central gain layer is formed by folding the coextruded DBR film to enclose a dye-doped skin layer. By mechanically stretching the elastomer laser film from 0% to 19%, a tunable miniature laser source was obtained with ˜50 nm continuous tunability from red to green.
Clinical effects of CO2 laser on equine diseases
NASA Astrophysics Data System (ADS)
Lindholm, Arne; Svensson, Ulf; Collinder, Eje
2002-10-01
CO2 lasers has been used for five years at Malaren Equine Hospital, as an alternative treatment of some equine diseases. The application of CO2 laser has been studied for evaluation of its appropriateness for treatment of the equine diseases sarcoids, lameness in fetlock joints or pulmonary haemorrhage. During the last five years, above 100 equine sarcoids have been removed by laser surgery (CO2 laser) and so far resulting in significantly few recurrences compared with results from usual excision surgery. In one study, acute traumatic arthritis in fetlock joints was treated three times every second day with defocalised CO2 laser. The therapeutic effectiveness of CO2 laser in this study was better than that of the customary therapy with betamethasone plus hyaluronan. During one year, chronic pulmonary bleeders, namely exercise induced pulmonary haemorrhage, has been treated with defocalised CO2 laser. Six race horses have been treated once daily during five days. Until now, three of these horses have subsequently been successfully racing and no symptoms of pulmonary haemorrhage have been observed. These studies indicate that CO2 laser might be an appropriate therapy on sarcoids and traumatic arthritis, and probably also on exercise induced pulmonary haemorrhage. Other treatments for this pulmonary disease are few.
NASA Astrophysics Data System (ADS)
Levin, Andrey V.
1996-04-01
High-speed, efficient method of laser surface treatment has been developed using (500 W) cw CO2 laser. The principal advantages of CO2 laser surface treatment in comparison with solid state lasers are the basis of the method. It has been affirmed that high efficiency of welding was a consequence of the fundamental properties of metal-IR-radiation (10,6 mkm) interaction. CO2 laser hermetization of metal frames of microelectronic devices is described as an example of the proposed method application.
Multi-species trace gas sensing with dual-wavelength QCLs
NASA Astrophysics Data System (ADS)
Hundt, P. Morten; Tuzson, Béla; Aseev, Oleg; Liu, Chang; Scheidegger, Philipp; Looser, Herbert; Kapsalidis, Filippos; Shahmohammadi, Mehran; Faist, Jérôme; Emmenegger, Lukas
2018-06-01
Instrumentation for environmental monitoring of gaseous pollutants and greenhouse gases tends to be complex, expensive, and energy demanding, because every compound measured relies on a specific analytical technique. This work demonstrates an alternative approach based on mid-infrared laser absorption spectroscopy with dual-wavelength quantum cascade lasers (QCLs). The combination of two dual- and one single-DFB QCL yields high-precision measurements of CO (0.08 ppb), CO2 (100 ppb), NH3 (0.02 ppb), NO (0.4 ppb), NO2 (0.1 ppb), N2O (0.045 ppb), and O3 (0.11 ppb) simultaneously in a compact setup (45 × 45 cm2). The lasers are driven time-multiplexed in intermittent continuous wave mode with a repetition rate of 1 kHz. The individual spectra are real-time averaged (1 s) by an FPGA-based data acquisition system. The instrument was assessed for environmental monitoring and benchmarked with reference instrumentation to demonstrate its potential for compact multi-species trace gas sensing.
NASA Astrophysics Data System (ADS)
Slack, Christopher L.; Pankratov, Michail M.; Perrault, Donald F., Jr.; Shapshay, Stanley M.; Aretz, H. Thomas
1993-07-01
The CO2 laser has been limited in its application within the tracheobronchial tree by its lack of a fiber delivery system. Recently a new product has been marketed, Luxar's flexible CO2 laser waveguide or FlexiguideTM, a spin-off of the presently used rigid waveguide or MicroguideTM. The study was undertaken so as to delineate the properties and thus the usefulness of this new product which promised an increased ease of delivery of the CO2 laser wavelength. We compared the flexiguide with its rigid counterpart along two parameters. Specifically, we determined the total energy necessary to endoscopically resect bovine tracheal rings with each guide and then examined the histologic crater characteristics of each guide at a given energy setting. In so doing we endeavored to see if the experience of the surgeon with the microguide could be translated to the use of the flexiguide. We found the flexiguide to require a greater total energy than the microguide in the continuous wave (cw) and chopped pulse (cp) operational modes p < 0.01. There was, however, no demonstrated difference in required energy in the superpulse (sp) operational mode. Preliminary histologic evidence when measuring such indices as crater depth, crater width, and shoulder width thermal damage seem to suggest that the flexiguide is less efficient at tissue ablation than its rigid counterpart at the same given energy. It also appears to cause a greater degree of associated thermal injury.
A numerical simulation of machining glass by dual CO 2-laser beams
NASA Astrophysics Data System (ADS)
Jiao, Junke; Wang, Xinbing
2008-03-01
In the flat panel display (FPD) industry, lasers may be used to cut glass plates. In order to reduce the possibility of fracture in the process of cutting glass by lasers, the thermal stress has to be less than the critical rupture strength. In this paper, a dual-laser-beam method is proposed, where an off-focus CO 2-laser beam was used to preheat the glass sample to reduce the thermal gradients and a focused CO 2-laser beam was used to machine the glass. The distribution of the thermal stress and the temperature was simulated by using finite element analysis software, Ansys. The thermal stress was studied both when the glass sample was machined by a single CO 2-laser beam and by dual CO 2-laser beams. It was concluded that the thermal stress can be reduced by means of the dual-laser-beam method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, James F.; Sams, Robert L.; Blake, Thomas A.
2012-02-06
A capillary absorption spectrometer (CAS) suitable for IR laser isotope analysis of small CO{sub 2} samples is presented. The system employs a continuous-wave (cw) quantum cascade laser to study nearly adjacent rovibrational transitions of different isotopologues of CO{sub 2} near 2307 cm{sup -1} (4.34 {mu}m). This initial CAS system can achieve relative isotopic precision of about 10 ppm {sup 13}C, or {approx}1{per_thousand} (per mil in delta notation relative to Vienna Pee Dee Belemnite) with 20-100 picomoles of entrained sample within the hollow waveguide for CO{sub 2} concentrations {approx}400 to 750 ppm. Isotopic analyses of such gas fills in a 1-mmmore » ID hollow waveguide of 0.8 m overall physical path length can be carried out down to {approx}2 Torr. Overall {sup 13}C/{sup 12}C ratios can be calibrated to {approx}2{per_thousand} accuracy with diluted CO{sub 2} standards. A novel, low-cost method to reduce cw-fringing noise resulting from multipath distortions in the hollow waveguide is presented, which allows weak absorbance features to be studied at the few ppm level (peak-to-rms) after 1,000 scans are co-added in {approx}10 sec. The CAS is meant to work directly with converted CO{sub 2} samples from a Laser Ablation-Catalytic-Combustion (LA CC) micro-sampler to provide {sup 13}C/{sup 12}C ratios of small biological isolates with spatial resolutions {approx}50 {mu}m.« less
In situ study of the anticariogenic potential of fluoride varnish combined with CO2 laser on enamel.
Souza-Gabriel, Aline Evangelista; Turssi, Cecília Pedroso; Colucci, Vivian; Tenuta, Lívia Maria Andaló; Serra, Mônica Campos; Corona, Silmara Aparecida Milori
2015-06-01
This in situ study evaluated the effect of fluoride varnish combined with CO2 laser in controlling enamel demineralization caused by cariogenic challenges. In a crossover study conducted in 2 phases of 14 days each, 14 volunteers (n = 14) wore palatal appliances with bovine enamel slabs treated with fluoride varnish + CO2 laser (FV + CO2), fluoride varnish (FV), nonfluoride placebo varnish (PV) and nonfluoride placebo varnish + CO2 laser (PV + CO2). Drops of sucrose solution were dripped onto enamel slabs allowing the accumulation of biofilm. At the first phase, half of the volunteers received 4 enamel slabs treated with FV while the remainders received slabs exposed to the PV with and without CO2 laser. In the second phase, the vonlunteers were reversed treatments. The slabs were evaluated for cross-sectional microhardness (CSMH) and the concentration of loosely bound fluoride (CaF2) and firmly bound fluoride (FAp). The concentration of fluoride in biofilm were also determined. Two-way ANOVA showed that the CSMH values were higher in laser-irradiated enamel, regardless of the fluoride varnish. Friedman test showed that FV group presented significantly larger amount of fluoride in biofilm (P < 0.05). In the enamel, the largest amount of fluoride was found in the groups FV + CO2, which was not different from FV (P > 0.05). The synergistic effect of fluoride varnish and CO2 laser on enamel demineralization was not observed, however, CO2 laser reduces enamel demineralization. CO2 laser might reduce the demineralization of subsurface enamel, although its association with a high concentrated fluoride therapy may not result in a positive synergistic interaction. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ultraviolet absorption cross-sections of hot carbon dioxide
NASA Astrophysics Data System (ADS)
Oehlschlaeger, Matthew A.; Davidson, David F.; Jeffries, Jay B.; Hanson, Ronald K.
2004-12-01
The temperature-dependent ultraviolet absorption cross-section for CO 2 has been measured in shock-heated gases between 1500 and 4500 K at 216.5, 244, 266, and 306 nm. Continuous-wave lasers provide the spectral brightness to enable precise time-resolved measurements with the microsecond time-response needed to monitor thermal decomposition of CO 2 at temperatures above 3000 K. The photophysics of the highly temperature dependent cross-section is discussed. The new data allows the extension of CO 2 absorption-based temperature sensing methods to higher temperatures, such as those found in behind detonation waves.
Medical Applications Of CO2 Laser Fiber Optics
NASA Astrophysics Data System (ADS)
McCord, R. C.
1981-07-01
In 1978, Hughes Laboratories reported development of fiber optics that were capable of transmitting CO2 laser energy. These fibers are now being tested for medical applications. Wide ranging medical investigation with CO2 lasers has occurred during the twelve years since the first observations of laser hemostasis. Specialists in ophthalmology, neurosurgery, urology, gynecology, otolaryngology, maxillo-facial/plastic surgery, dermatology, and oncology among others, have explored its use. In principle, all these specialists use CO2 laser radiation at 10.6 microns to thermally destroy diseased tissues. As such, CO2 lasers compare and compete with electrosurgical devices. The fundamental difference between these modalities lies in how they generate heat in treated tissue.
Surface Modification of Thermal Barrier Coatings by Single-Shot Defocused Laser Treatments
NASA Astrophysics Data System (ADS)
Akdoğan, Vakur; Dokur, Mehmet M.; Göller, Gültekin; Keleş, Özgül
2013-09-01
Thermal barrier coatings (TBC) consisting of atmospheric plasma-sprayed ZrO2-8 wt.% Y2O3 and a high velocity oxygen fuel-sprayed metallic bond coat were subjected to CO2 continuous wave laser treatments. The effects of laser power on TBCs were investigated as was the thermally grown oxide (TGO) layer development of all as-sprayed and laser-treated coatings after thermal oxidation tests in air environment for 50, 100, and 200 h at 1100 °C. The effects of laser power on TBCs were investigated. TGO layer development was examined on all as-sprayed and laser-treated coatings after thermal oxidation tests in air environment for 50, 100, and 200 h at 1100 °C. Melted and heat-affected zone regions were observed in all the laser-treated samples. Oxidation tests showed a stable alumina layer and mixed spinel oxides in the TGO layers of the as-sprayed and laser-treated TBCs.
Lei, Ying; Li, Shi Feng; Yu, Yi Ling; Tan, Jun; Gold, Michael H
2017-06-01
Hypertrophic scarring is seen regularly. Tissue penetration of laser energy into hypertrophic scars using computer defaults from some lasers may be insufficient and penetration not enough. We have developed a treatment with an interrupted laser "drilling" by the Ultrapulse CO 2 (Manual Fractional Technology, MFT) and, a second pass, with fractional CO 2 . The MFT with fractional CO 2 lasers to treat hypertrophic scars is evaluated. A total of 158 patients with hypertrophic scars had three sessions of MFT with fractional CO 2 laser at 3-month intervals. Evaluations made before and 6 months after the 3rd treatment: (1) the Vancouver Scar Scale (VSS), (2) the University of North Carolina (UNC) Scar Scale, and (3) a survey of patient satisfaction. All data were analyzed using a t-test before and after treatment. The VSS score decreased from 9.35 to 3.12 (P<.0001), and the UNC Scar Scale score decreased from 8.03 to 1.62 (P<.0001). The overall satisfaction rate was 92%. No long-term complications occurred in the clinical trial. The interrupted laser drilling by MFT and a fractional CO2 laser had profound effects on the hypertrophic scars treated. It works by increasing the penetration depth of the CO 2 laser in the scar tissue, exerting more precise effects on the hypertrophic scars. MFT combined with fractional CO 2 laser has the potential to be a major advance in the treatment of hypertrophic scars. © 2017 Wiley Periodicals, Inc.
The choice: Welding with CO2 or Nd:YAG lasers
NASA Astrophysics Data System (ADS)
Leong, Keng H.
The recent commercial availability of multi-kilowatt Nd:YAG lasers has opened new avenues for rapid laser processing as well as intensified the competition (cost effectiveness) between CO2 and Nd:YAG laser systems. Vendors offering Nd:YAG laser systems may claim lower operating costs (than CO2) and fiberoptic beam delivery flexibility while CO2 systems vendors may emphasize lower capital cost and well established processing requirements and experience. The capital and operating costs of a laser system are impacted by demand and supply economics and technological advances. Frequently the total cost of a workcell using a laser for processing has to be considered rather than the laser system alone. Consequently it is not very practical to approach the selection of a laser system based on its capital cost and estimated operating cost only. This presentation describes a more pragmatic approach to aid the user in the selection of the optimal multi-kilowatt laser system for a particular processing requirement with emphasis on welding. CO2 laser systems are well established on the factory floor. Consequently, emphasis is given to the comparative application of Nd:YAG lasers, process requirements and performance. Requirements for the laser welding of different metals are examined in the context of hardware (laser system and beam delivery) selection and examples of welding speeds that can be achieved using CO2 and Nd:YAG lasers are examined.
Ivanov, Borislav L; Wellons, Matthew S; Lukehart, Charles M
2009-08-26
A one-step process for preparing microcrystalline coatings of known superhard, very hard, or ultraincompressible ceramic compositions on either inorganic or organic supports is reported. Midinfrared pulsed-laser irradiation of preceramic chemical precursors layered between IR-transmissive hard/soft supports under temporal and spatial confinement at a laser wavelength resonant with a precursor vibrational band gives one-step deposition of crystalline ceramic coatings without incurring noticeable collateral thermal damage to the support material. Reaction plume formation at the precursor/laser beam interface initiates confined-plume, chemical deposition (CPCD) of crystalline ceramic product. Continuous ceramic coatings are produced by rastering the laser beam over a sample specimen. CPCD processing of the Re-B single-source precursor, (B(3)H(8))Re(CO)(4), the dual-source mixtures, Ru(3)(CO)(12)/B(10)H(14) or W(CO)(6)/B(10)H(14), and the boron/carbon single-source precursor, o-B(10)C(2)H(12), confined between Si wafer or NaCl plates gives microcrystalline deposits of ReB(2), RuB(2), WB(4), or B(4)C, respectively. CPCD processing of Kevlar fabric wetted by (B(3)H(8))Re(CO)(4) produces an oriented, microcrystalline coating of ReB(2) on the Kevlar fabric without incurring noticeable thermal damage of the polymer support. Similarly, microcrystalline coatings of ReB(2) can be formed on IR-transmissive IR2, Teflon, or Ultralene polymer films.
Polarization characteristic of a room-temperature Co:MgF2 laser.
Zhang, Zengming M; Cui, Yiben B; Li, Fuli L; Zhang, Guobin B; Pu, Qirong R; Xu, Gaojie J
2002-02-20
A study of the polarization characteristic of a Co:MgF2 laser with a 1320-nm YAG pumping laser at room temperature is reported. The thresholds, output energies, and efficiencies of the laser are given at the various polarization states. The more intensive emission is in the pi-polarization pump laser and sigma-polarization laser operation. Performances of the Co:MgF2 lasers are similar for the polarized and unpolarized laser pumping along the optical axis of the crystal.
QCL seeded, ns-pulse, multi-line, CO2 laser oscillator for laser-produced-plasma extreme-UV source
NASA Astrophysics Data System (ADS)
Nowak, Krzysztof Michał; Suganuma, Takashi; Kurosawa, Yoshiaki; Ohta, Takeshi; Kawasuji, Yasufumi; Nakarai, Hiroaki; Saitou, Takashi; Fujimoto, Junichi; Mizoguchi, Hakaru; Sumitani, Akira; Endo, Akira
2017-01-01
Successful merger of state-of-the-art, semiconductor quantum-cascade lasers (QCL), with the mature CO2 laser technology, resulted in a delivery of highly-desired qualities of CO2 laser output that were not available previously without much effort. These qualities, such as multi-line operation, excellent spectro-temporal stability and pulse waveform control, became available from a single device of moderate complexity. This paper describes the operation principle and the unique properties of the solid{state seeded CO2 laser, invented for an application in laser-produced-plasma (LPP), extreme-UV (EUV) light source.
Technology assessment of high pulse energy CO(2) lasers for remote sensing from satellites
NASA Technical Reports Server (NTRS)
Hess, R. V.; Brockman, P.; Schryer, D. R.; Miller, I. M.; Bair, C. H.; Sidney, B. D.; Wood, G. M.; Upchurch, B. T.; Brown, K. G.
1985-01-01
Developments and needs for research to extend the lifetime and optimize the configuration of CO2 laser systems for satellite based on remote sensing of atmospheric wind velocities and trace gases are reviewed. The CO2 laser systems for operational satellite application will require lifetimes which exceed 1 year. Progress in the development of efficient low temperature catalysts and gas mixture modifications for extending the lifetime of high pulse energy closed cycle common and rare isotope CO2 lasers and of sealed CW CO2 lasers is reviewed. Several CO2 laser configurations are under development to meet the requirements including: unstable resonators, master oscillator power amplifiers and telescopic stable resonators, using UV or E-beam preionization. Progress in the systems is reviewed and tradeoffs in the system parameters are discussed.
NASA Astrophysics Data System (ADS)
Obland, M. D.; Nehrir, A. R.; Lin, B.; Harrison, F. W.; Kooi, S. A.; Choi, Y.; Plant, J.; Yang, M. M.; Antill, C.; Campbell, J. F.; Ismail, S.; Browell, E. V.; Meadows, B.; Dobler, J. T.; Zaccheo, T. S.; Moore, B., III; Crowell, S.
2014-12-01
The ASCENDS CarbonHawk Experiment Simulator (ACES) is an Intensity-Modulated Continuous-Wave lidar system recently developed at NASA Langley Research Center that seeks to advance technologies and techniques critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. These advancements include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. ACES simultaneously transmits five laser beams: three from commercial EDFAs operating near 1571 nm, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1260 nm. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The outgoing laser beams are aligned to the field of view of ACES' three fiber-coupled 17.8-cm diameter athermal telescopes. The backscattered light collected by the three telescopes is sent to the detector/TIA subsystem, which has a bandwidth of 4.7 MHz and operates service-free using a tactical dewar and cryocooler. Two key laser modulation approaches are being tested to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these flights will be presented in this paper.
NASA Technical Reports Server (NTRS)
Mckenzie, R. L.
1972-01-01
Predictions from a numerical model of the vibrational relaxation of anharmonic diatomic oscillators in supersonic expansions are used to show the extent to which the small anharmonicity of gases like CO can cause significant overpopulations of upper vibrational states. When mixtures of CO and N2 are considered, radiative gain on many of the vibration-rotation transitions of CO is predicted. Experiments are described that qualitatively verify the predictions by demonstrating laser oscillation in CO-N2 expansions. The resulting CO-N2 gasdynamic laser displays performance characteristics that equal or exceed those of similar CO2 lasers.
NASA Technical Reports Server (NTRS)
Mckenzie, R. L.
1971-01-01
Predictions from a numerical model of the vibrational relaxation of anharmonic diatomic oscillators in supersonic expansions are used to show the extent to which the small anharmonicity of gases like CO can cause significant overpopulations of upper vibrational states. When mixtures of CO and N2 are considered, radiative gain on many of the vibration-rotation transitions of CO is predicted. Experiments are described that qualitatively verify the predictions by demonstrating laser oscillation in CO-N2 expansions. The resulting CO-N2 gasdynamic laser displays performance characteristics that equal or exceed those of similar CO2 lasers.
Comparative study of upper lip frenectomy with the CO2 laser versus the Er, Cr: YSGG laser
Pié-Sánchez, Jordi; España-Tost, Antonio J.; Arnabat-Domínguez, Josep
2012-01-01
Objectives: To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. Study design: A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Results: Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Conclusions: Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing. Key words:Frenectomy, upper lip frenulum, CO2 laser, Er,Cr:YSGG laser, laser. PMID:22143683
Co removal and phase transformations during high power diode laser irradiation of cemented carbide
NASA Astrophysics Data System (ADS)
Barletta, M.; Rubino, G.; Gisario, A.
2011-02-01
The use of a continuous wave-high power diode laser for removing surface Co-binder from Co-cemented tungsten carbide (WC-Co (5.8 wt%.)) hardmetal slabs was investigated. Combined scanning electron microscopy, energy dispersive X-ray spectroscopy and X-ray diffraction analyses were performed in order to study the phase transformations and micro-structural modifications of the WC-Co substrates occurring during and after laser irradiation. The micro-structure of the WC-Co progressively transforms as energy density increased, exhibiting stronger removal of Co and WC grain growth. At very high energy density, local melting of the WC grains with the formation of big agglomerates of interlaced grains is observed, and the crystalline structure of the irradiated substrate shows the presence of a brittle ternary eutectic phase of W, Co and C (often referred to as the η-phase). The latter can be detrimental to the mechanical properties of WC-Co. Therefore, the proper adjustment of the laser processing parameters plays a crucial role in surface treatments of WC-Co substrates prior to post-processing like diamond deposition.
Surface hardening using cw CO2 laser: laser heat treatment, modelation, and experimental work
NASA Astrophysics Data System (ADS)
Muniz, German; Alum, Jorge
1996-02-01
In the present work are given the results of the application of laser metal surface hardening techniques using a cw carbon dioxide laser as an energy source on steel 65 G. The laser heat treatment results are presented theoretically and experimentally. Continuous wave carbon dioxide laser of 0.6, 0.3, and 0.4 kW were used. A physical model for the descriptions of the thermophysical laser metal interactions process is given and a numerical algorithm is used to solve this problem by means of the LHT code. The results are compared with the corresponding experimental ones and a very good agreement is observed. The LHT code is able to do predictions of transformation hardening by laser heating. These results will be completed with other ones concerning laser alloying and cladding presented in a second paper.
High power CO2 coherent ladar haven't quit the stage of military affairs
NASA Astrophysics Data System (ADS)
Zhang, Heyong
2015-05-01
The invention of the laser in 1960 created the possibility of using a source of coherent light as a transmitter for a laser radar (ladar). Coherent ladar shares many of the basic features of more common microwave radars. However, it is the extremely short operating wavelength of lasers that introduces new military applications, especially in the area of missile identification, space target tracking, remote rang finding, camouflage discrimination and toxic agent detection. Therefore, the most popular application field such as laser imaging and ranging were focused on CO2 laser in the last few decades. But during the development of solid state and fiber laser, some people said that the CO2 laser will be disappeared and will be replaced by the solid and fiber laser in the field of military and industry. The coherent CO2 laser radar will have the same destiny in the field of military affairs. However, to my opinion, the high power CO2 laser will be the most important laser source for laser radar and countermeasure in the future.
NASA Astrophysics Data System (ADS)
Khumaeni, Ali; Sugito, Heri; Yoyo Wardaya, Asep; Setia Budi, Wahyu
2018-05-01
Identification of macro nutrients in medicine is really necessary for healthy purpose. In this study, identification of macro elements in pharmaceutical products was carried out by laser-induced plasma spectroscopy (LIPS). A comparative study was made by employing different types of laser, namely an Nd:YAG laser and a pulse TEA CO2 laser. Experimentally, the laser beam was directed and focused by a convex lens on a mineral supplement tablet. A luminous plasma was induced on the tablet’s surface. Sharp and high-intensity emission spectra of macro elements including Ca and Mg were detected both in LIBS using Nd:YAG and pulse CO2 lasers. However, the intensities of Ca and Mg spectra are much higher for the LIBS using CO2 laser. Based on the analysis, the plasma temperature plays important role in the spectra. Namely, the plasma induced by a TEA CO2 laser is much higher than that of Nd:YAG laser; the plasma temperature for the case of TEA CO2 laser and Nd:YAG laser were 6400 K and 4500 K, respectively.
Design of catalytic monoliths for closed-cycle carbon dioxide lasers
NASA Technical Reports Server (NTRS)
Herz, R. K.; Guinn, K.; Goldblum, S.; Noskowski, E.
1989-01-01
Pulsed carbon dioxide (CO2) lasers have many applications in aeronautics, space research, weather monitoring and other areas. Full exploitation of the potential of these lasers in hampered by the dissociation of CO2 that occurs during laser operation. The development of closed-cycle CO2 lasers requires active CO-O2 recombination (CO oxidation) catalyst and design methods for implementation of catalysts in CO2 laser systems. A monolith catalyst section model and associated design computer program, LASCAT, are presented to assist in the design of a monolith catalyst section of a closed cycle CO2 laser system. Using LASCAT,the designer is able to specify a number of system parameters and determine the monolith section performance. Trade-offs between the catalyst activity, catalyst dimensions, monolith dimensions, pressure drop, O2 conversion, and other variables can be explored and adjusted to meet system design specifications. An introduction describes a typical closed-cycle CO2 system, and indicates some advantages of a closed cycle laser system over an open cycle system and some advantages of monolith support over other types of supports. The development and use of a monolith catalyst model is presented. The results of a design study and a discussion of general design rules are given.
Carbon dioxide laser fiber for the excision of oral leukoplakia.
Chee, Michael; Sasaki, Clarence
2013-09-01
We compared the efficacies of cold knife excision and carbon dioxide (CO2) laser fiber excision of oral cavity leukoplakia. Between August 2009 and June 2011,45 patients who underwent excision of oral cavity leukoplakia were assessed for operative time, use of bipolar cautery, blood loss, and number of intraoperative margins needed. Patients were assigned randomly to either a cold knife group (23 procedures) or a CO2 laser fiber group (24 procedures) at the time of the procedure. The times of excision were similar in the CO2 laser fiber group (1.64 min/cm2) and the cold knife group (1.70 min/cm2). There were large differences between the CO2 laser fiber group and the cold knife group in the categories of bipolar cautery uses per square centimeter (0.34 uses versus 3.32 uses) and blood loss (0.19 g/cm2 versus 2.55 g/cm2). The average number of margins needed to clear a specimen by frozen section was 1.21 for the CO2 laser fiber group and 1.83 for the cold knife group. The CO2 laser fiber did not show an advantage in operative time. The CO2 laser fiber did show better outcomes in the areas of blood loss, bipolar cautery use, and intraoperative margins needed.
Eruptive keratoacanthomas following carbon dioxide laser resurfacing.
Gewirtzman, A; Meirson, D H; Rabinovitz, H
1999-08-01
Skin resurfacing with the carbon dioxide (CO2) laser is currently a popular means of improving rhytides and scars. Scarring, hyperpigmentation, hypopigmentation, and infection are among the complications that have been known to occur in some patients treated with the CO2 laser. We wish to communicate a previously unreported complication of CO2 laser resurfacing-multiple eruptive keratoacanthomas. We describe a 61-year-old woman who presented with multiple eruptive keratoacanthomas subsequent to CO2 laser resurfacing. Her lesions were cultured for fungus and bacteria. Biopsy specimens of two lesions were taken. Cultures were negative for pathogens. Biopsy specimens revealed atypical squamous epithelial proliferation and changes consistent with eruptive keratoacanthomas. Multiple eruptive keratoacanthomas should be considered as a rare complication of CO2 laser resurfacing.
NASA Astrophysics Data System (ADS)
Matsukuma, Hiraku; Hosoda, Tatsuya; Suzuki, Yosuke; Yogo, Akifumi; Yanagida, Tatsuya; Kodama, Takeshi; Nishimura, Hiroaki
2016-08-01
The two-color, double-pulse method is an efficient scheme to generate extreme ultraviolet light for fabricating the next generation semiconductor microchips. In this method, a Nd:YAG laser pulse is used to expand a several-tens-of-micrometers-scale tin droplet, and a CO2 laser pulse is subsequently directed at the expanded tin vapor after an appropriate delay time. We propose the use of shadowgraphy with a CO2 laser probe-pulse scheme to optimize the CO2 main-drive laser. The distribution of absorption coefficients is derived from the experiment, and the results are converted to a practical absorption rate for the CO2 main-drive laser.
Kamalski, Digna M A; Vincent, Robert; Wegner, Inge; Bittermann, Arnold J N; Grolman, Wilko
2014-12-01
Comparing hearing results in patients with otosclerosis treated with laser-assisted stapedotomy using the 2-μm thulium laser or the CO2 laser. Prospective nonrandomized clinical study. In a tertiary referral center in France (Jean Causse Ear Clinic, Béziers), 208 primary stapedotomies were performed in 204 patients between March 2008 and November 2009. Sufficient follow-up data were available for 194 procedures. The fenestration in the footplate was made with the thulium laser in 98 procedures and with a flexible CO2 laser in 96 procedures. Preoperative and postoperative audiometric results were compared. Side effects, such as vertigo and tinnitus, were scored. Patients treated with the CO2 laser had better hearing outcome compared with those treated with the thulium laser at both 3 and 12 months of follow-up. At 3 months, the success of the surgery, defined as closure of the air-bone gap to within 10 dB, was 90.0% in the thulium group compared with 96.8% in the CO2 group. Bone conduction shift showed an overall deterioration of 1.6 dB (standard deviation, 6.9 dB) in the thulium group compared with an improvement of 1.3 dB (standard deviation, 4 dB) in the CO2 group. In the thulium group, there were four patients with sensorineural hearing loss (4.4%) and three with tinnitus (3.1%) compared with none in the CO2 group. Stapedotomy surgery performed with a fiber-delivered thulium laser resulted in a higher chance of inner ear damage measured by bone conduction shift compared with the use of a fiber-delivered CO2 laser. We advise not to use the thulium laser for stapedotomy.
Wada, Ryuichi; Matsumi, Yutaka; Takanashi, Satoru; Nakai, Yuichiro; Nakayama, Tomoki; Ouchi, Mai; Hiyama, Tetsuya; Fujiyoshi, Yasushi; Nakano, Takashi; Kurita, Naoyuki; Muramoto, Kenichiro; Kodama, Naomi
2016-12-01
We conducted continuous, high time-resolution measurements of CO2 and water vapour isotopologues ((16)O(12)C(16)O, (16)O(13)C(16)O and (18)O(12)C(16)O for CO2, and H2(18)O for water vapour) in a red pine forest at the foot of Mt. Fuji for 9 days from the end of July 2010 using in situ absorption laser spectroscopy. The δ(18)O values in water vapour were estimated using the δ(2)H-δ(18)O relationship. At a scale of several days, the temporal variations in δ(18)O-CO2 and δ(18)O-H2O are similar. The orders of the daily Keeling plots are almost identical. A possible reason for the similar behaviour of δ(18)O-CO2 and δ(18)O-H2O is considered to be that the air masses with different water vapour isotopic ratios moved into the forest, and changed the atmosphere of the forest. A significant correlation was observed between δ(18)O-CO2 and δ(13)C-CO2 values at nighttime (r(2)≈0.9) due to mixing between soil (and/or leaf) respiration and tropospheric CO2. The ratios of the discrimination coefficients (Δa/Δ) for oxygen (Δa) and carbon (Δ) isotopes during photosynthesis were estimated in the range of 0.7-1.2 from the daytime correlations between δ(18)O-CO2 and δ(13)C-CO2 values.
Measurements of Forest-Atmosphere Isotopic CO2 Exchange by Eddy Covariance
NASA Astrophysics Data System (ADS)
Wehr, R. A.; Munger, J. W.; Nelson, D. D.; McManus, J. B.; Zahniser, M. S.; Saleska, S. R.
2010-12-01
Isotopic CO2 flux measurements are a promising means for partitioning the net ecosystem exchange of CO2 into photosynthetic and respiratory components. This approach to partitioning is possible in principle because of the distinct isotopic signatures of respired and photosynthesized CO2, but has been infeasible in practice—especially in forests—because of the difficulty of measuring isotopic ratios with sufficient precision and time response for use in eddy covariance (EC) flux calculations. Recent advances in laser spectroscopic instrumentation have changed that. We report measurements of isotopic (13C and 18O) CO2 exchange made by eddy covariance at Harvard Forest between April and December, 2010. The measurements were made using a continuous-wave quantum cascade laser spectrometer (Aerodyne Research Inc.) sampling at 4 Hz and are, to our knowledge, the first EC isotopic flux measurements at a forest site. The spectrometer can measure δ13C and δ18O with internal precisions (standard deviation of 1-minute averages) of 0.03 ‰, and [CO2] with an internal precision of 15 ppb; the instrumental accuracy, calibration, and long-term stability are discussed in detail. The isotopic data are considered in relation to environmental variables (PAR, temperature, humidity, soil temperature and moisture), and a first attempt at flux partitioning using the isotopic fluxes is presented.
Calibrating Laser Gas Measurements by Use of Natural CO2
NASA Technical Reports Server (NTRS)
Webster, Chris
2003-01-01
An improved method of calibration has been devised for instruments that utilize tunable lasers to measure the absorption spectra of atmospheric gases in order to determine the relative abundances of the gases. In this method, CO2 in the atmosphere is used as a natural calibration standard. Unlike in one prior calibration method, it is not necessary to perform calibration measurements in advance of use of the instrument and to risk deterioration of accuracy with time during use. Unlike in another prior calibration method, it is not necessary to include a calibration gas standard (and the attendant additional hardware) in the instrument and to interrupt the acquisition of atmospheric data to perform calibration measurements. In the operation of an instrument of this type, the beam from a tunable diode laser or a tunable quantum-cascade laser is directed along a path through the atmosphere, the laser is made to scan in wavelength over an infrared spectral region that contains one or two absorption spectral lines of a gas of interest, and the transmission (and, thereby, the absorption) of the beam is measured. The concentration of the gas of interest can then be calculated from the observed depth of the absorption line(s), given the temperature, pressure, and path length. CO2 is nearly ideal as a natural calibration gas for the following reasons: CO2 has numerous rotation/vibration infrared spectral lines, many of which are near absorption lines of other gases. The concentration of CO2 relative to the concentrations of the major constituents of the atmosphere is well known and varies slowly and by a small enough amount to be considered constant for calibration in the present context. Hence, absorption-spectral measurements of the concentrations of gases of interest can be normalized to the concentrations of CO2. Because at least one CO2 calibration line is present in every spectral scan of the laser during absorption measurements, the atmospheric CO2 serves continuously as a calibration standard for every measurement point. Figure 1 depicts simulated spectral transmission measurements in a wavenumber range that contains two absorption lines of N2O and one of CO2. The simulations were performed for two different upper-atmospheric pressures for an airborne instrument that has a path length of 80 m. The relative abundance of CO2 in air was assumed to be 360 parts per million by volume (approximately its natural level in terrestrial air). In applying the present method to measurements like these, one could average the signals from the two N2O absorption lines and normalize their magnitudes to that of the CO2 absorption line. Other gases with which this calibration method can be used include H2O, CH4, CO, NO, NO2, HOCl, C2H2, NH3, O3, and HCN. One can also take advantage of this method to eliminate an atmospheric-pressure gauge and thereby reduce the mass of the instrument: The atmospheric pressure can be calculated from the temperature, the known relative abundance of CO2, and the concentration of CO2 as measured by spectral absorption. Natural CO2 levels on Mars provide an ideal calibration standard. Figure 2 shows a second example of the application of this method to Mars atmospheric gas measurements. For sticky gases like H2O, the method is particularly powerful, since water is notoriously difficult to handle at low concentrations in pre-flight calibration procedures.
Potential of CO2 lasers (10.6 µm) associated with fluorides in inhibiting human enamel erosion.
Ramos-Oliveira, Thayanne Monteiro; Ramos, Thaysa Monteiro; Esteves-Oliveira, Marcela; Apel, Christian; Fischer, Horst; Eduardo, Carlos de Paula; Steagall, Washington; Freitas, Patricia Moreira de
2014-01-01
This in vitro study aimed to investigate the potential of CO2 lasers associated with different fluoride agents in inhibiting enamel erosion. Human enamel samples were randomly divided into 9 groups (n = 12): G1-eroded enamel; G2-APF gel; G3-AmF/NaF gel; G4-AmF/SnF2 solution; G5-CO2 laser (λ = 10.6 µm)+APF gel; G6-CO2 laser+AmF/NaF gel; G7-CO2laser+AmF/SnF2solution; G8-CO2 laser; and G9-sound enamel. The CO2 laser parameters were: 0.45 J/cm2; 6 μs; and 128 Hz. After surface treatment, the samples (except from G9) were immersed in 1% citric acid (pH 4.0, 3 min). Surface microhardness was measured at baseline and after surface softening. The data were statistically analyzed by one-way ANOVA and Tukey's tests (p < 0.05). G2 (407.6 ± 37.3) presented the highest mean SMH after softening, followed by G3 (407.5 ± 29.8) and G5 (399.7 ± 32.9). Within the fluoride-treated groups, G4 (309.0 ± 24.4) had a significantly lower mean SMH than G3 and G2, which were statistically similar to each other. AmF/NaF and APF application showed potential to protect and control erosion progression in dental enamel, and CO2 laser irradiation at 0.45J/cm2 did not influence its efficacy. CO2 laser irradiation alone under the same conditions could also significantly decrease enamel erosive mineral loss, although at lower levels.
Tsuyumu, M; Verasques, G; Yamazaki, S; Kuroiwa, T; Suzuki, R; Takei, H; Suzuki, K; Inaba, Y
1985-04-01
The CO2 laser is useful for cutting and vaporization but not for coagulation and hemostasis. On the contrary, YAG laser is effective for coagulation and hemostasis but not for cutting. The purpose of this study is to examine the effect of the exposure of combined, coaxial CO2 and YAG laser on the animal brain to supplement the advantages and draw-backs of each other. To compare these results, each of non-combined pulse wave form CO2 and YAG lasers was employed separately. The lasers in this study were pulse wave form CO2 and YAG lasers, employed separately or simultaneously using 130 YZ of Nihon Infrared Industries Company. Japanese white rabbits were anesthetized with pentobarbital. Fronto-parietal burr holes were made, the dura was removed and then Evans blue solution was injected intravenously. The lasers were employed to the cerebral cortex without great vessels using a micromanipulator attached to the operative microscope with a distance of 30 cm. The spot size was 700 mu for CO2 laser and 1200 mu for YAG laser. The first experiment was to see the effect of nine combinations of simultaneous coaxial CO2 of 2, 4 and 8 watts and YAG lasers of 10, 20 and 40 watts, 1 sec on the brain. In the second experiment, also combining two lasers, the exposure time of YAG laser was elongated from 1 or 2 seconds into 2 or 4 seconds and the arrangement of powers was the same as that of the first experiment. The lesions were thus made in 18 different conditions.(ABSTRACT TRUNCATED AT 250 WORDS)
A blackbody-pumped CO2-N2 transfer laser
NASA Astrophysics Data System (ADS)
Deyoung, R. J.; Higdon, N. S.
1984-08-01
A compact blackbody-pumped CO2-N2 transfer laser was constructed and the significant operating parameters were investigated. Lasing was achieved at 10.6 microns by passing preheated N2 through a 1.5-mm-diameter nozzle to a laser cavity where the N2 was mixed with CO2 and He. An intrinsic efficiency of 0.7 percent was achieved for an oven temperature of 1473 K and N2 oven pressure of 440 torr. The optimum laser cavity consisted of a back mirror with maximum reflectivity and an output mirror with 97.5-percent reflectivity. The optimum gas mixture was 1CO2/.5He/6N2. The variation of laser output was measured as a function of oven temperature, nozzle diameter, N2 oven pressure, He and CO2 partial pressures, nozzle-to-oven separation, laser cell temperature, and output laser mirror reflectivity. With these parameters optimized, outputs approaching 1.4 watts were achieved.
A blackbody-pumped CO2-N2 transfer laser
NASA Technical Reports Server (NTRS)
Deyoung, R. J.; Higdon, N. S.
1984-01-01
A compact blackbody-pumped CO2-N2 transfer laser was constructed and the significant operating parameters were investigated. Lasing was achieved at 10.6 microns by passing preheated N2 through a 1.5-mm-diameter nozzle to a laser cavity where the N2 was mixed with CO2 and He. An intrinsic efficiency of 0.7 percent was achieved for an oven temperature of 1473 K and N2 oven pressure of 440 torr. The optimum laser cavity consisted of a back mirror with maximum reflectivity and an output mirror with 97.5-percent reflectivity. The optimum gas mixture was 1CO2/.5He/6N2. The variation of laser output was measured as a function of oven temperature, nozzle diameter, N2 oven pressure, He and CO2 partial pressures, nozzle-to-oven separation, laser cell temperature, and output laser mirror reflectivity. With these parameters optimized, outputs approaching 1.4 watts were achieved.
Healing of rat mouth mucosa after irradiation with CO2, Nd:YAG, and CO2-Nd:YAG combination lasers.
Luomanen, M; Rauhamaa-Mäkinen, R; Meurman, J H; Kosloff, T; Tiitta, O
1994-08-01
The healing process of wounds made by a combination laser was studied in 90 rats. The laser system enabled both separate and combined use of CO2 and Nd:YAG laser irradiations. The laser wounds and the control excision wounds made by alligator forceps appeared on both sides of the tongue. Specimens from the wound sites were taken immediately, 6 h, and 1, 2, 4, 7, 11, 21, 28, and 42 days after surgery. The wound-healing process was studied by macroscopic evaluation before preparing the specimens for light microscopy. Some differences were noted in the wound-healing process among the three groups into which the experimental animals were divided. Tissue coagulation damage was most extensive in the Nd:YAG laser sites, where it was observed in its full extent 4 days after surgery. Epithelial cells were seen to begin to proliferate in all the wounds 6 h after surgery. Re-epithelialization was completed by between 7 (CO2) and 21 days (Nd:YAG) at all the wound sites. The inflammatory cell infiltration was more prominent in the Nd:YAG and the CO2-Nd:YAG combination laser wounds than in the CO2 and excision wounds during healing. Tissue regeneration occurred faster with less contraction in the combination CO2-Nd:YAG wounds than in Nd:YAG wounds. The best macroscopic healing result was seen in the CO2 wound sites. The combination laser was effective both at cutting and at coagulating tissue. Combining the CO2 and Nd:YAG laser irradiation into one beam resulted in a greater incision depth than what could have been expected from using the two lasers separately.
Tao, Lei; Sun, Kang; Khan, M Amir; Miller, David J; Zondlo, Mark A
2012-12-17
A compact and portable open-path sensor for simultaneous detection of atmospheric N(2)O and CO has been developed with a 4.5 μm quantum cascade laser (QCL). An in-line acetylene (C(2)H(2)) gas reference cell allows for continuous monitoring of the sensor drift and calibration in rapidly changing field environments and thereby allows for open-path detection at high precision and stability. Wavelength modulation spectroscopy (WMS) is used to detect simultaneously both the second and fourth harmonic absorption spectra with an optimized dual modulation amplitude scheme. Multi-harmonic spectra containing atmospheric N(2)O, CO, and the reference C(2)H(2) signals are fit in real-time (10 Hz) by combining a software-based lock-in amplifier with a computationally fast numerical model for WMS. The sensor consumes ~50 W of power and has a mass of ~15 kg. Precision of 0.15 ppbv N(2)O and 0.36 ppbv CO at 10 Hz under laboratory conditions was demonstrated. The sensor has been deployed for extended periods in the field. Simultaneous N(2)O and CO measurements distinguished between natural and fossil fuel combustion sources of N(2)O, an important greenhouse gas with poorly quantified emissions in space and time.
Selective material ablation by the TEA CO2 laser
NASA Astrophysics Data System (ADS)
Sumiyoshi, Tetsumi; Shiratori, Akira; Ninomiya, Yutaka; Obara, Minoru
1995-03-01
This paper reports two topics in the material processing using TEA CO2 lasers. We demonstrated selective ablation of hydrogenated amorphous silicon (a-Si:H) thin layer on a quartz substrate by the second harmonic (SH) radiation of TEA CO2 laser generated by AgGaSe2 nonlinear crystal. Si-H bonds contained in a-Si:H strongly absorb the 5 micrometers SH radiation and resulted in the selective ablation of the a-Si:H layer. The successful ablation processing of ethylenetetrafluoroethylene (ETFE) copolymer by the 9.6 micrometers fundamental wavelength TEA CO2 laser is also reported. Only ETFE thin film adhered to an aluminum substrate can be ablated by the TEA CO2 laser.
Cavity-Enhanced Quantum-Cascade Laser-Based Instrument for Trace gas Measurements
NASA Astrophysics Data System (ADS)
Provencal, R.; Gupta, M.; Owano, T.; Baer, D.; Ricci, K.; O'Keefe, A.
2005-12-01
An autonomous instrument based on Off-Axis Integrated Cavity Output Spectroscopy has been successfully deployed for measurements of CO in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument consists of a measurement cell comprised of two high reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data acquisition electronics, and data analysis software. The instrument reports CO mixing ratio at a 1-Hz rate based on measured absorption, gas temperature and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41000 ft, the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights. We will also present recent development efforts to extend the instrument's capabilities for the measurements of CH4, N2O and CO in real time.
REVIEWS OF TOPICAL PROBLEMS: Gas lasers with solar excitation
NASA Astrophysics Data System (ADS)
Gordiets, B. F.; Panchenko, Vladislav Ya
1986-07-01
CONTENTS 1. Introduction 703 2. General requirements for laser media using solar excitation 704 3. Lasers with direct excitation by solar light 705 3.1. Basic characteristics of laser media. 3.2. Photodissociation Br2-CO2 lasers. 3.3. Interhalogen molecule lasers. 3.4. Iodine lasers. 3.5. Alkali metal vapor lasers. 4. Lasers with thermal conversion of solar pumping 709 4.1. General considerations. 4.2. CO2 laser with excitation in a black body cavity and with gas flow. 4.3. cw CO2 laser without gas flow. 5. Space laser media with solar excitation 713 5.1. Population inversion of molecular levels in the outer atmosphere of the Earth. 5.2. Laser effect in the atmospheres of Venus and Mars. 5.3. Terrestrial experimental technique for observing infrared emission in the atmospheres of planets. 5.4. Designs for laser systems in the atmospheres of Venus and Mars. 6. Conclusions 717 References 717
Comparison of Ultrasonic and CO2 Laser Pretreatment Methods on Enzyme Digestibility of Corn Stover
Tian, Shuang-Qi; Wang, Zhen-Yu; Fan, Zi-Luan; Zuo, Li-Li
2012-01-01
To decrease the cost of bioethanol production, biomass recalcitrance needs to be overcome so that the conversion of biomass to bioethanol becomes more efficient. CO2 laser irradiation can disrupt the lignocellulosic physical structure and reduce the average size of fiber. Analyses with Fourier transform infrared spectroscopy, specific surface area, and the microstructure of corn stover were used to elucidate the enhancement mechanism of the pretreatment process by CO2 laser irradiation. The present work demonstrated that the CO2 laser had potential to enhance the bioconversion efficiency of lignocellulosic waste to renewable bioethanol. The saccharification rate of the CO2 laser pretreatment was significantly higher than ultrasonic pretreatment, and reached 27.75% which was 1.34-fold of that of ultrasonic pretreatment. The results showed the impact of CO2 laser pretreatment on corn stover to be more effective than ultrasonic pretreatment. PMID:22605970
NASA Technical Reports Server (NTRS)
Wang, Liang-Guo; Sachse, Glen
1990-01-01
Closed-cycle CO2 laser operation with removal of O2 and regeneration of CO2 can be achieved by catalytic CO-O2 recombination. Both parametric studies of the optimum catalyst formulation and long-term performance tests require on line monitoring of CO, O2 and CO2 concentrations. There are several existing methods for molecular oxygen detection. These methods are either intrusive (such as electrochemical method or mass spectrometry) or very expensive (such as CARS, UV laser absorption). Researchers demonstrated a high-sensitivity spectroscopic measurement of O2 using the two-tone frequency modulation spectroscopy (FMS) technique with a near infrared GaAlAs diode laser. Besides its inexpensive cost, fast response time, nonintrusive measurements and high sensitivity, this technique may also be used to differentiate between isotopes due to its high spectroscopic resolution. This frequency modulation spectroscopy technique could also be applied for the on-line monitoring of CO and CO2 using InGaAsP diode lasers operation in the 1.55 microns region and H2O in the 1.3 microns region. The existence of single mode optical fibers at the near infrared region makes it possible to combine FMS with optical fiber technology. Optical fiber FMS is particularly suitable for making point-measurements at one or more locations in the CO2 laser/catalyst system.
Source technology as the foundation for modern infra-red counter measures (IRCM)
NASA Astrophysics Data System (ADS)
Grasso, Robert J.
2010-10-01
Protection of military aircraft from IR guided threats is paramount to ensure the survivability of aircrews, platforms, and to ensure mission success. At the foundation of all IRCM systems is the source; that component that provides the in-band radiant energy required for threat defeat. As such, source technology has evolved with IRCM technology to encompass the evolving systems architectures that encompass IRCM: 1) "Hot Brick" omni-directional sources; 2) arc lamps, and; 3) lasers. Lasers, as IRCM sources continue to evolve to meet the challenges of ever-evolving threats, superior techniques, economy of installation, and superior source technology. Lasers represent the single greatest advance in IRCM source technology and continue to evolve to meet ever more sophisticated threats. And have been used with great effect in all modern IRCM systems; evolving from frequency doubled CO2 lasers, to solid state lasers with OPOs, to semiconductor lasers including Quantum Cascade Lasers (QCLs); these last devices represent the latest advance in IRCM source technology offering all-band coverage, architectural simplicity, and economy of scale. While QCLs represent the latest advance in IRCM laser technology, fiber lasers show much promise in addressing multi-band operation as well as the ability to be coherently combined to achieve even greater output capability. Also, ultra-short pulse lasers are evolving to become practical for IRCM applications. Stay tuned ......
[Measuring microhardness of laser exposed tooth surface].
Florin, R; Herrmann, C; Bernhardt, W
1990-02-01
In principle it is possible to homogenize the enamel surface by melting structural elements with the continuous wave CO2 laser. Using the precision instrument NEOPHOT 2 (Carl Zeiss JENA) the microhardness of extracted laserexposed premolares were tested so as to clarify the functional strain capasity and the mechanical characteristics of laserexposed regions of enamel surfaces. The proven higher hardness in the centre of the laserinduced fusing zones (in comparison with adjacent enamel) objectify an attainable refining of the enamel surface that probably causes an increase in the caries-preventive resistance.
LaRC-developed catalysts for CO2 lasers
NASA Technical Reports Server (NTRS)
Upchurch, Billy T.; Kielin, Erik J.; Miller, Irvin M.
1990-01-01
Pulsed CO2 lasers have many remote sensing applications from space, airborne, and ground platforms. The NASA Laser Atmospheric Wind Sounder (LAWS) system will be designed to measure wind velocities from polar earth orbit for a period of up to three years. Accordingly, this and other applications require a closed-cycle pulsed CO2 laser which necessitates the use of an efficient CO-O2 recombination catalyst for these dissociation products which otherwise would degrade the laser operation. The required catalyst must not only operate at low temperatures but also must operate efficiently for long time periods. The research effort at NASA LaRC has centered around development and testing of CO oxidation catalysts for closed-cycle, pulsed, common and rare-isotope CO2 lasers. Researchers examined available commercial catalysts both in a laser and under simulated closed-cycle laser conditions with efforts aimed toward a thorough understanding of the fundamental catalytic reaction. These data were used to design and synthesize new catalyst compositions to better meet the catalyst requirements for closed-cycle pulsed CO2 lasers. Syntheses and test results for catalysts developed at Langley Research Center which have significantly better long-term decay characteristics than previously available catalysts and at the same time operate quite well under lower temperature conditions are discussed.
Recent developments in CO2 lasers
NASA Astrophysics Data System (ADS)
Du, Keming
1993-05-01
CO2 lasers have been used in industry mainly for such things as cutting, welding, and surface processing. To conduct a broad spectrum of high-speed and high-quality applications, most of the developments in industrial CO2 lasers at the ILT are aimed at increasing the output power, optimizing the beam quality, and reducing the production costs. Most of the commercial CO2 lasers above 5 kW are transverse-flow systems using dc excitation. The applications of these lasers are limited due to the lower beam quality, the poor point stability, and the lower modulation frequency. To overcome the problems we developed a fast axial- flow CO2 laser using rf excitation with an output of 13 kW. In section 2 some of the results are discussed concerning the gas flow, the discharge, the resonator design, optical effects of active medium, the aerodynamic window, and the modulation of the output power. The first CO2 lasers ever built are diffusion-cooled systems with conventional dc excited cylindrical discharge tubes surrounded by cooling jackets. The output power per unit length is limited to 50 W/m by those lasers with cylindrical tubes. In the past few years considerable increases in the output power were achieved, using new mechanical geometries, excitation- techniques, and resonator designs. This progress in diffusion-cooled CO2 lasers is presented in section 3.
High repetition rate sealed CO2 TEA lasers using heterogeneous catalysts
NASA Astrophysics Data System (ADS)
Price, H. T.; Shaw, S. R.
1987-04-01
The significant operational advantages offered by CO2 lasers, operating in the 10.6 micron region of the spectrum, over current solid state lasers, emitting in the near IR region, have prompted increased interest in the development of compact, reliable, rugged CO2 laser sources. Perhaps the most critical aspect associated with achieving a laser compatible with military use is the development of lasers which require no gas replenishment. Sealed, single shot, CO2 TEA lasers have been available for a number of years. Stark et al were first to demonstrate reliable sealed operation in single shot CO2 TEA lasers in 1975 using gas catalysis. GEC Avionics reported the compact, environmentally qualified, MKIII CO2 TEA laser with a pulse life of greater than 10 to the 6th power pulses in 1980. A sealed laser lifetime of greater than 10 to the 6th power pulses is acceptable for single shot cases, such as direct detection rangefinders for tank laser sights. However, in many other applications, such as tracking of fast moving targets, it is essential that a repetition rate of typically 30Hz to 100Hz is employed. In such cases, a pulse lifetime of 10 to the 6th power pulses is no longer sufficient and a minimum pulse lifetime 10 to the 7th power pulses is essential to ensure a useful service life. In 1983 Stark el al described a sealed, 100Hz CO2 TEA laser, with a life of greater than 2.6 x 10 to the 6th power, which employed heterogeneous catalysis. Following this pioneering work, GEC Avionics has been engaged in the development of sealed high repetition rate lasers with a pulse lifetime of 20 million pulses.
High repetition rate sealed CO2 TEA lasers using heterogeneous catalysts
NASA Technical Reports Server (NTRS)
Price, H. T.; Shaw, S. R.
1987-01-01
The significant operational advantages offered by CO2 lasers, operating in the 10.6 micron region of the spectrum, over current solid state lasers, emitting in the near IR region, have prompted increased interest in the development of compact, reliable, rugged CO2 laser sources. Perhaps the most critical aspect associated with achieving a laser compatible with military use is the development of lasers which require no gas replenishment. Sealed, single shot, CO2 TEA lasers have been available for a number of years. Stark et al were first to demonstrate reliable sealed operation in single shot CO2 TEA lasers in 1975 using gas catalysis. GEC Avionics reported the compact, environmentally qualified, MKIII CO2 TEA laser with a pulse life of greater than 10 to the 6th power pulses in 1980. A sealed laser lifetime of greater than 10 to the 6th power pulses is acceptable for single shot cases, such as direct detection rangefinders for tank laser sights. However, in many other applications, such as tracking of fast moving targets, it is essential that a repetition rate of typically 30Hz to 100Hz is employed. In such cases, a pulse lifetime of 10 to the 6th power pulses is no longer sufficient and a minimum pulse lifetime 10 to the 7th power pulses is essential to ensure a useful service life. In 1983 Stark el al described a sealed, 100Hz CO2 TEA laser, with a life of greater than 2.6 x 10 to the 6th power, which employed heterogeneous catalysis. Following this pioneering work, GEC Avionics has been engaged in the development of sealed high repetition rate lasers with a pulse lifetime of 20 million pulses.
Suter, Valerie G A; Altermatt, Hans Jörg; Bornstein, Michael M
2017-04-01
This study was conducted in order to compare clinical and histopathological outcomes for excisional biopsies when using pulsed CO 2 laser versus Er:YAG laser. Patients (n = 32) with a fibrous hyperplasia in the buccal mucosa were randomly allocated to the CO 2 (140 Hz, 400 μs, 33 mJ) or the Er:YAG laser (35 Hz, 297 μs, 200 mJ) group. The duration of excision, intraoperative bleeding and methods to stop the bleeding, postoperative pain (VAS; ranging 0-100), the use of analgesics, and the width of the thermal damage zone (μm) were recorded and compared between the two groups. The median duration of the intervention was 209 s, and there was no significant difference between the two methods. Intraoperative bleeding occurred in 100% of the excisions with Er:YAG and 56% with CO 2 laser (p = 0.007). The median thermal damage zone was 74.9 μm for CO 2 and 34.0 μm for Er:YAG laser (p < 0.0001). The median VAS score on the evening after surgery was 5 for the CO 2 laser and 3 for the Er:YAG group. To excise oral soft tissue lesions, CO 2 and Er:YAG lasers are both valuable tools with a short time of intervention and postoperative low pain. More bleeding occurs with the Er:YAG than CO 2 laser, but the lower thermal effect of Er:YAG laser seems advantageous for histopathological evaluation.
NASA Technical Reports Server (NTRS)
Kosterev, A. A.; Tittel, F. K.; Durante, W.; Allen, M.; Kohler, R.; Gmachl, C.; Capasso, F.; Sivco, D. L.; Cho, A. Y.
2002-01-01
We report the first application of pulsed, near-room-temperature quantum cascade laser technology to the continuous detection of biogenic CO production rates above viable cultures of vascular smooth muscle cells. A computer-controlled sequence of measurements over a 9-h period was obtained, resulting in a minimum detectable CO production of 20 ppb in a 1-m optical path above a standard cell-culture flask. Data-processing procedures for real-time monitoring of both biogenic and ambient atmospheric CO concentrations are described.
Chen, Yujin; Lin, Yanfu; Huang, Jianhua; Gong, Xinghong; Luo, Zundu; Huang, Yidong
2018-01-08
A composite crystal consisting of a 1.5-mm-thick Er:Yb:YAl 3 (BO 3 ) 4 crystal between two 1.2-mm-thick sapphire crystals was fabricated by the thermal diffusion bonding technique. Compared with a lone Er:Yb:YAl 3 (BO 3 ) 4 crystal measured under the identical experimental conditions, higher laser performances were demonstrated in the sapphire/Er:Yb:YAl 3 (BO 3 ) 4 /sapphire composite crystal due to the reduction of the thermal effects. End-pumped by a 976 nm laser diode in a hemispherical cavity, a 1.55 μm continuous-wave laser with a maximum output power of 1.75 W and a slope efficiency of 36% was obtained in the composite crystal when the incident pump power was 6.54 W. Passively Q-switched by a Co 2+ :MgAl 2 O 4 crystal, a 1.52 μm pulse laser with energy of 10 μJ and repetition frequency of 105 kHz was also realized in the composite crystal. Pulse width was 315 ns. The results show that the sapphire/Er:Yb:YAl 3 (BO 3 ) 4 /sapphire composite crystal is an excellent active element for 1.55 μm laser.
Development of high-power CO2 lasers and laser material processing
NASA Astrophysics Data System (ADS)
Nath, Ashish K.; Choudhary, Praveen; Kumar, Manoj; Kaul, R.
2000-02-01
Scaling laws to determine the physical dimensions of the active medium and optical resonator parameters for designing convective cooled CO2 lasers have been established. High power CW CO2 lasers upto 5 kW output power and a high repetition rate TEA CO2 laser of 500 Hz and 500 W average power incorporated with a novel scheme for uniform UV pre- ionization have been developed for material processing applications. Technical viability of laser processing of several engineering components, for example laser surface hardening of fine teeth of files, laser welding of martensitic steel shroud and titanium alloy under-strap of turbine, laser cladding of Ni super-alloy with stellite for refurbishing turbine blades were established using these lasers. Laser alloying of pre-placed SiC coating on different types of aluminum alloy, commercially pure titanium and Ti-6Al-4V alloy, and laser curing of thermosetting powder coating have been also studied. Development of these lasers and results of some of the processing studies are briefly presented here.
Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.
Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R
2005-11-01
An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.
Natekar, Madhukar; Raghuveer, Hosahallli-Puttaiah; Rayapati, Dilip-Kumar; Shobha, Eshwara-Singh; Prashanth, Nagesh-Tavane; Rangan, Vinod; Panicker, Archana G
2017-06-01
The comparatively evaluate the three surgical treatment modalities namely cryosurgery, diode and CO2 laser surgery in terms of healing outcomes on the day of surgery, first and second week post operatively and recurrence at the end of 18 months was assessed. Thirty selected patients were divided randomly into three groups. Each group comprising of ten patients were subjected to one of the three modalities of treatment namely cryosurgery, diode laser or CO2 laser surgery for ablation of OL. Obtained data was analyzed using mainly using Chi-square and Anova tests. Study showed statistical significant differences (p > 0.05) for evaluation parameters like pain, edema and scar. The parameters like infection, recurrence, bleeding showed no statistical significance. Pain was significantly higher in CO2 laser surgery group as compared with diode laser group. There was no recurrence observed at the end of the 6 months follow up period in all the three study groups. Observations from the study highlights that all three surgical modalities used in this study were effective for treatment of OL, and the overall summation of the results of the study showed that laser therapy (CO2 and Diode) seems to offer better clinically significant results than cryotherapy. Key words: Oral premalignant lesion, leukoplakia, cryosurgery, CO2 laser surgery, diode laser surgery.
CO2 laser treatment for regional cutaneous malignant melanoma metastases.
van Jarwaarde, Jorien A; Wessels, Ronnie; Nieweg, Omgo E; Wouters, Michel W J M; van der Hage, Jos A
2015-01-01
Cutaneous in-transit and satellite metastases are distressing presentations of melanoma progression. The purpose of this study was to analyze the efficacy of carbon dioxide (CO2) lasers in patients with melanoma with cutaneous in-transit and satellite metastases. Results of CO2 laser therapy were retrospectively evaluated in 22 patients between January 2004 and January 2008. The number of laser treatments, postoperative morbidity, regional control, and overall survival were analyzed. Twenty-two patients received a total of 42 CO2 laser treatments. The number of lesions treated per session varied from 3 to 329. The median duration of regional control in all patients was 14 weeks (range, 3-117). In 9 of 22 patients, only 1 treatment with CO2 laser was performed resulting in a mean regional control of 11 weeks. In 10 patients, an average of 4 laser treatments (range, 1-17) was necessary to achieve regional control. Three of the 22 patients underwent isolated limb perfusion after laser treatment for disease control. This study shows that (repeated) laser treatment can achieve adequate regional control with little morbidity. CO2 laser is recommended as a first-line treatment to patients with small but numerous cutaneous satellite or in-transit lesions in whom other surgery would induce substantial morbidity.
The spectrum of laser skin resurfacing: nonablative, fractional, and ablative laser resurfacing.
Alexiades-Armenakas, Macrene R; Dover, Jeffrey S; Arndt, Kenneth A
2008-05-01
The drive to attain cosmetic facial enhancement with minimal risk and rapid recovery has inspired the field of nonsurgical skin rejuvenation. Laser resurfacing was introduced in the 1980s with continuous wave carbon dioxide (CO(2)) lasers; however, because of a high rate of side effects, including scarring, short-pulse, high-peak power, and rapidly scanned, focused-beam CO(2) lasers and normal-mode erbium-doped yttrium aluminium garnet lasers were developed, which remove skin in a precisely controlled manner. The prolonged 2-week recovery time and small but significant complication risk prompted the development of non-ablative and, more recently, fractional resurfacing in order to minimize risk and shorten recovery times. Nonablative resurfacing produces dermal thermal injury to improve rhytides and photodamage while preserving the epidermis. Fractional resurfacing thermally ablates microscopic columns of epidermal and dermal tissue in regularly spaced arrays over a fraction of the skin surface. This intermediate approach increases efficacy as compared to nonablative resurfacing, but with faster recovery as compared to ablative resurfacing. Neither nonablative nor fractional resurfacing produces results comparable to ablative laser skin resurfacing, but both have become much more popular than the latter because the risks of treatment are limited in the face of acceptable improvement. At the completion of this learning activity, participants should be familiar with the spectrum of lasers and light technologies available for skin resurfacing, published studies of safety and efficacy, indications, methodologies, side effects, complications, and management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Deyong; Li, Yunliang; Li, Hao
2015-05-15
Knowledge of dynamical structure of protein is an important clue to understand its biological function in vivo. Temperature-jump (T-jump) time-resolved transient mid-IR absorbance spectroscopy is a powerful tool in elucidating the protein dynamical structures and the folding/unfolding kinetics of proteins in solution. A home-built setup of T-jump time-resolved transient mid-IR absorbance spectroscopy with high sensitivity is developed, which is composed of a Q-switched Cr, Tm, Ho:YAG laser with an output wavelength at 2.09 μm as the T-jump heating source, and a continuous working CO laser tunable from 1580 to 1980 cm{sup −1} as the IR probe. The results demonstrate thatmore » this system has a sensitivity of 1 × 10{sup −4} ΔOD for a single wavelength detection, and 2 × 10{sup −4} ΔOD for spectral detection in amide I′ region, as well as a temporal resolution of 20 ns. Moreover, the data quality coming from the CO laser is comparable to the one using the commercial quantum cascade laser.« less
1976-07-01
A AD PROPAGATION OF HIGH POWER PULSES OF 10.6 pm RADIATION FROM A C02 TEA LASER OF NOVEL DESIGN THROUGH CLOUDS PRODUCED BY ADIABATIC E•XPANS:’)N IN...PART A: CO2 LASER uEVELOPMENT Al High Power CO2 TEA Laser 2 A2 CW CO2 Laser 6 References 8 Diagrams 9 PART 8: CLOUD PROLDUCTION 61 Cloud Chamber...offer versatility, efficienr-y and high power . This report is concerned with the attenuation of 10.eum radiatiins, both high power pulsL.o and 04, by
Ansari, Fereshteh; Sadeghi-Ghyassi, Fatemeh; Yaaghoobian, Barmak
2018-01-31
Fractional CO 2 has many indications in medicine including in treatment of acne scars and rejuvenation. The aim of this study was to evaluate the safety, efficacy, and cost-effectiveness of Fractional CO 2 Laser in comparison with other methods of rejuvenation and acne scar treatment. Several databases including Medline, OVID, EMBASE, CINHAL, SCOPUS, Web of science, CRD, and Cochrane were searched. After conducting the search and evaluation of selected publications, critical appraisal was done and eligible studies were accepted for inclusion in the systematic review. From 2667 identified publications two of the trials were eligible. The effectiveness and complications of Fractional CO 2 laser were comparable with Er:YAG but Fractional CO 2 laser was 14.7% (p = 0.01) more effective than Q-Switched ND:YAG laser. Cost affectivity of this method was the same as other alternative lasers. In conclusion Fractional CO 2 laser is an effective and safe method for curing of several kinds of skin diseases. Nevertheless there was not sufficient evidence to support its advantage. This device has equal or lower price in comparison to competent technologies except for the non- fractional ablative CO 2 laser that has the same or lower price and comparable effects.
Osman, Mai Abdel Raouf; Kassab, Ahmed Nazmi
2017-08-01
A verrucous epidermal nevus (VEN) is a skin disorder that has been treated using different treatment modalities with varying results. Ablative lasers such as carbon dioxide laser (CO 2 ) and erbium:yttrium-aluminum-garnet (Er:YAG) laser have been considered as the gold standard for the treatment of epidermal nevi. To evaluate and compare the efficacy, postoperative wound healing and side effects of pulsed CO 2 laser and Er:YAG laser for the treatment of verrucous epidermal nevi. Twenty patients with localized VEN were randomly divided into two groups. Group 1 was administered CO 2 laser and group 2 underwent Er:YAG laser treatment. A blinded physician evaluated the photographs and dermoscopic photomicrographs for the efficacy and possible side effects. All patients received one treatment session and were followed up over a 6-month period. Both lasers induced noticeable clinical improvement, but there were no significant differences between two lasers in treatment response, patient satisfaction, duration of erythema and side effects. The average time to re-epithelialization was 13.5 days with CO 2 and 7.9 days with Er:YAG laser (p< .0005). No scarring was observed in Er:YAG laser group and no lesional recurrence was detected in CO 2 laser group since treatment. Apart from re-epithelialization, both lasers showed equivalent outcomes with respect to treatment response, patient satisfaction, side effects and complications.
Pulsed infrared difference frequency generation in CdGeAs.sub.2
Piltch, Martin S.; Rink, John P.; Tallman, Charles R.
1977-03-08
The disclosure relates to a laser apparatus for generating a line-tunable pulsed infrared difference frequency output. The apparatus comprises a CO.sub.2 laser which produces a first frequency, a CO laser which produces a second frequency and a mixer for combining the output of the CO.sub.2 and CO lasers so as to produce a final output comprising a difference frequency from the first and second frequency outputs.
Pulsed infrared difference frequency generation in CdGeAs/sub 2/
Piltch, M.S.; Rink, J.P.; Tallman, C.R.
1975-11-26
A laser apparatus for generating a line-tunable pulsed infrared difference frequency output is described. The apparatus comprises a CO/sub 2/ laser which produces a first frequency, a CO laser which produces a second frequency, and a mixer for combining the output of the CO/sub 2/ and CO lasers so as to produce a final output comprising a difference frequency from the first and second frequency outputs.
Study into penetration speed during laser cutting of brain tissues.
Yilbas, Z; Sami, M; Patiroglu, T
1998-01-01
The applications of CO2 continuous-wave lasers in neurosurgery have become important in recent years. Theoretical considerations of laser applicability in medicine are subsequently confirmed experimentally. To obtain precision operation in the laser cutting process, further theoretical developments and experimental studies need to be conducted. Consequently, in the present study, the heat transfer mechanism taking place during laser-tissue interaction is introduced using Fourier theory. The results obtained from the theoretical model are compared with the experimental results. In connection with this, an experiment is designed to measure the penetration speed during the laser cutting process. The measurement is carried out using an optical method. It is found that both results for the penetration speed obtained from the theory and experiment are in a good agreement.
NASA Astrophysics Data System (ADS)
Santoni, G. W.; Daube, B. C.; Kort, E. A.; Jiménez, R.; Park, S.; Pittman, J. V.; Gottlieb, E.; Xiang, B.; Zahniser, M. S.; Nelson, D. D.; McManus, J. B.; Peischl, J.; Ryerson, T. B.; Holloway, J. S.; Andrews, A. E.; Sweeney, C.; Hall, B.; Hintsa, E. J.; Moore, F. L.; Elkins, J. W.; Hurst, D. F.; Stephens, B. B.; Bent, J.; Wofsy, S. C.
2014-06-01
We present an evaluation of aircraft observations of the carbon and greenhouse gases CO2, CH4, N2O, and CO using a direct-absorption pulsed quantum cascade laser spectrometer (QCLS) operated during the HIPPO and CalNex airborne experiments. The QCLS made continuous 1 Hz measurements with 1σ Allan precisions of 20, 0.5, 0.09, and 0.15 ppb for CO2, CH4, N2O, and CO, respectively, over > 500 flight hours on 79 research flights. The QCLS measurements are compared to two vacuum ultraviolet (VUV) CO instruments (CalNex and HIPPO), a cavity ring-down spectrometer (CRDS) measuring CO2 and CH4 (CalNex), two broadband non-dispersive infrared (NDIR) spectrometers measuring CO2 (HIPPO), two onboard gas chromatographs measuring a variety of chemical species including CH4, N2O, and CO (HIPPO), and various flask-based measurements of all four species. QCLS measurements are tied to NOAA and WMO standards using an in-flight calibration system, and mean differences when compared to NOAA CCG flask data over the 59 HIPPO research flights were 100, 1, 1, and 2 ppb for CO2, CH4, N2O, and CO, respectively. The details of the end-to-end calibration procedures and the data quality assurance and quality control (QA/QC) are presented. Specifically, we discuss our practices for the traceability of standards given uncertainties in calibration cylinders, isotopic and surface effects for the long-lived greenhouse gas tracers, interpolation techniques for in-flight calibrations, and the effects of instrument linearity on retrieved mole fractions.
Bailey, J Kevin; Blackstone, Britani N; DeBruler, Danielle M; Kim, Jayne Y; Baumann, Molly E; McFarland, Kevin L; Imeokparia, Folasade O; Supp, Dorothy M; Powell, Heather M
2018-01-01
The use of pulsed dye laser (PDL) and fractional CO 2 (FX CO 2 ) laser therapy to treat and/or prevent scarring following burn injury is becoming more widespread with a number of studies reporting reduction in scar erythema and pruritus following treatment with lasers. While the majority of studies report positive outcomes following PDL or FX CO 2 therapy, a number of studies have reported no benefit or worsening of the scar following treatment. The objective of this study was to directly compare the efficacy of PDL, FX CO 2 , and PDL + FX CO 2 laser therapy in reducing scarring post burn injury and autografting in a standardized animal model. Eight female red Duroc pigs (FRDP) received 4 standardized, 1 in. x 1 in. third degree burns that were excised and autografted. Wound sites were treated with PDL, FX CO 2 , or both at 4, 8, and 12 weeks post grafting. Grafts receiving no laser therapy served as controls. Scar appearance, morphology, size, and erythema were assessed and punch biopsies collected at weeks 4, 8, 12, and 16. At week 16, additional tissue was collected for biomechanical analyses and markers for inflammatory cytokines, extracellular matrix (ECM) proteins, re-epithelialization, pigmentation, and angiogenesis were quantified at all time points using qRT-PCR. Treatment with PDL, FX CO 2 , or PDL + FX CO 2 resulted in significantly less contraction versus skin graft only controls with no statistically significant difference among laser therapy groups. Scars treated with both PDL and FX CO 2 were visually more erythematous than other groups with a significant increase in redness between two and three standard deviations above normal skin redness. Scars treated with FX CO 2 were visually smoother and contained significantly fewer wrinkles. In addition, hyperpigmentation was significantly reduced in scars treated with FX CO 2 . The use of fractional carbon dioxide or pulsed dye laser therapy within 1 month of autografting significantly reduced scar contraction versus control, though no statistically significant difference was detected between laser modalities or use of both modalities. Overall, FX CO 2 therapy appears to be modestly more effective at reducing erythema, and improving scar texture and biomechanics. The current data adds to prior studies supporting the role of laser therapy in the treatment of burn scars and indicates more study is needed to optimize delivery protocols for maximum efficacy. Lasers Surg. Med. 50:78-87, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Structure and properties of optical-discharge plasma in CO2-laser beam near target surface
NASA Astrophysics Data System (ADS)
Danshchikov, Ye. V.; Dymshakov, V. A.; Lebedev, F. V.; Ryazanov, A. V.
1986-05-01
An experimental study of optical-discharge plasma in a CO2-laser beam at a target surface was made for the purpose of exploring the not yet understood role of this plasma in the laser-target interaction process. Such a plasma was produced by means of a quasi-continuous CO2-laser with an unstable resonator, its power being maintained constant for 1 ms periods. Its radiation was focused on the surfaces of thick and seeding thin Al, Ti, and Ta targets inclined at an approximately 70 deg. angle to the beam, inside a hermetic chamber containing air, argon, or helium under atmospheric pressure. The radiation intensity distribution over the focal plane and the nearest caustic surface in the laser beam was measured along with the plasma parameters, the latter by the methods of spectral analysis and photoelectric recording. The instrumentation for this purpose included an MDR-3 monochromator with an entrance slit, a double electron-optical converter, a memory oscillograph, and an SI-10-30 ribbon lamp as radiation reference standard. The results yielded integral diametral intensity distributions of the emission lines Ti-II (457.2 nm), Ti-I (464 nm), Ar-II (462 nm), radial and axial temperature profiles of optical discharge in metal vapor in surrounding gas, and the radial temperature profile of irradiated metal surface at successive instants of time. The results reveal marked differences between the structures and the properties of optical-discharge plasma in metal vapor and in surrounding gas, optical discharge in the former being characterized by localization within the laser beam and optical discharge in the latter being characterized by a drift away from the target.
Spectral Analysis of Vibrational Harmonic Motion by use of a Continuous-Wave CO2 Doppler Lidar
NASA Technical Reports Server (NTRS)
Jarzembski, Maurice A.; Srivastava, Vandana
1999-01-01
Vibrational motion of a harmonic oscillator was investigated using a focused continuous wave CO2 Doppler lidar at 9.1 microns wavelength. A continuum of frequencies along with many discrete, equally spaced, resonant frequency modes was observed. The frequency modes are similar in structure to the oscillatory longitudinal modes of a laser cavity and arise because of interference of the natural resonant frequency of the oscillator with specific frequencies within the continuum. The spectra revealed departures from linear motion for vigorous vibrations of the oscillator. Each consecutive resonant frequency mode occurred for a movement of the oscillator much less than the wavelength of incident lidar radiation.
Villavicencio, Alan T; Burneikiene, Sigita; Babuska, Jason M; Nelson, Ewell L; Mason, Alexander; Rajpal, Sharad
2015-04-01
The purpose of this study was to evaluate potential technical advantages of the CO2 laser technology in mini-open transforaminal lumbar interbody fusion (TLIF) surgeries and report our preliminary clinical data on the safety and clinical outcomes. There is currently no literature discussing the recently redeveloped CO2 laser technology application for lumbar fusion. Safety and clinical outcomes were compared between two groups: 24 patients that underwent CO2 laser-assisted one-level TLIF surgeries and 30 patients that underwent standard one-level TLIF surgeries without the laser. There were no neural thermal injuries or other intraoperative laser-related complications encountered in this cohort of patients. At a mean follow-up of 17.4 months, significantly reduced lower back pain scores (P=0.013) were reported in the laser-assisted patient group compared to a standard fusion patient group. Lower extremity radicular pain intensity scores were similar in both groups. Laser-assisted TLIF surgeries showed a tendency (P = 0.07) of shorter operative times that was not statistically significant. Based on this preliminary clinical report, the safety of the CO2 laser device for lumbar fusion surgeries was assessed. There were no neural thermal injuries or other intraoperative laser-related complications encountered in this cohort of patients. Further investigation of CO2 laser-assisted lumbar fusion procedures is warranted in order to evaluate its effect on clinical outcomes.
Schoenewolf, Nicola L; Hafner, Jürg; Dummer, Reinhard; Bogdan Allemann, Inja
2015-04-01
Lentigines solares (LS) on the dorsum of hands are often esthetically disturbing. Q-switched ruby laser treatment is highly effective in the treatment of these lesions. Ablative fractional photothermolysis may be a suitable alternative. We compared the Q-switched ruby laser with ablative CO2 fractional photothermolysis for the treatment of solar lentigines. To evaluate the efficacy and side-effects of 694nm Q-switched ruby laser (Sinon) with the ablative 10,600nm CO2 fractional laser (Quantel Excel O2) in an intra-individual side-to-side comparison in the treatment of LS on the dorsum of hands. Eleven patients were included in the study. The hands of each patient were randomized for treatment with the two laser systems. Three treatment sessions were scheduled at weeks 0, 4 and 8. Evaluations by patients, treating physician and blinded experts were scheduled at weeks 0, 4, 8, 16 and 24. The Q-switched ruby laser was significantly more efficacious than the ablative CO2 fractional laser for removing LS on the dorsum of hands (p = 0.01). In this first study on this topic, the Q-switched ruby laser was superior to the ablative CO2 fractional laser in the treatment of lentigines solares on the dorsum of hands.
Bahrololoomi, Zahra; Sorouri, Milad
2015-01-01
Objectives: Fluoride therapy is important for control and prevention of dental caries. Laser irradiation can increase fluoride uptake especially when combined with topical fluoride application. The objective of this study was to compare the effects of CO2 and diode lasers on enamel fluoride uptake in primary teeth. Materials and Methods: Forty human primary molars were randomly assigned to four groups (n=10). The roots were removed and the crowns were sectioned mesiodistally into buccal and lingual halves as the experimental and control groups. All samples were treated with 5% sodium fluoride (NaF) varnish. The experimental samples in the four groups were irradiated with 5 or 7W diode or 1 or 2W CO2 laser for 15 seconds and were compared with the controls in terms of fluoride uptake, which was determined using an ion selective electrode after acid dissolution of the specimens. Data were analyzed by SPSS version 16 using ANOVA treating the control measurements as covariates. Results: The estimated amount of fluoride uptake was 59.5± 16.31 ppm, 66.5± 14.9 ppm, 78.6± 12.43 ppm and 90.4± 11.51 ppm for 5W and 7 W diode and 1W and 2 W CO2 lasers, respectively, which were significantly greater than the values in the conventional topical fluoridation group (P<0.005). There were no significant differences between 7W diode laser and 1W CO2 laser, 5W and 7W diode laser, or 1W and 2W CO2 laser in this regard. Conclusion: The results showed that enamel surface irradiation by CO2 and diode lasers increases the fluoride uptake. PMID:27123018
Bahrololoomi, Zahra; Fotuhi Ardakani, Faezeh; Sorouri, Milad
2015-08-01
Fluoride therapy is important for control and prevention of dental caries. Laser irradiation can increase fluoride uptake especially when combined with topical fluoride application. The objective of this study was to compare the effects of CO2 and diode lasers on enamel fluoride uptake in primary teeth. Forty human primary molars were randomly assigned to four groups (n=10). The roots were removed and the crowns were sectioned mesiodistally into buccal and lingual halves as the experimental and control groups. All samples were treated with 5% sodium fluoride (NaF) varnish. The experimental samples in the four groups were irradiated with 5 or 7W diode or 1 or 2W CO2 laser for 15 seconds and were compared with the controls in terms of fluoride uptake, which was determined using an ion selective electrode after acid dissolution of the specimens. Data were analyzed by SPSS version 16 using ANOVA treating the control measurements as covariates. The estimated amount of fluoride uptake was 59.5± 16.31 ppm, 66.5± 14.9 ppm, 78.6± 12.43 ppm and 90.4± 11.51 ppm for 5W and 7 W diode and 1W and 2 W CO2 lasers, respectively, which were significantly greater than the values in the conventional topical fluoridation group (P<0.005). There were no significant differences between 7W diode laser and 1W CO2 laser, 5W and 7W diode laser, or 1W and 2W CO2 laser in this regard. The results showed that enamel surface irradiation by CO2 and diode lasers increases the fluoride uptake.
Comparison of four different lasers for acne scars: Resurfacing and fractional lasers.
You, Hi-Jin; Kim, Deok-Woo; Yoon, Eul-Sik; Park, Seung-Ha
2016-04-01
Acne scars are common and cause cosmetic problems. There is a multitude of treatment options for acne scars, including dermabrasion, chemical peeling, and fillers, but the advent of laser technology has greatly improved the treatment of acne scars. Although several laser systems are available, studies comparing their efficacy are limited. This study compares the results of treatments using resurfacing (carbon dioxide, CO2; erbium-doped yttrium aluminum garnet, Er:YAG) versus fractional (nonablative fractional laser, NAFL; ablative fractional laser, AFL) lasers. A retrospective photographic analysis of 58 patients who underwent laser treatment for facial atrophic acne scars was performed. Clinical improvement was assessed by six blinded investigators with a scale graded from 0 to 10. Adverse events were also noted. Mean improvement scores of the CO2, Er:YAG, NAFL, and AFL groups were 6.0, 5.8, 2.2, and 5.2, respectively. The NAFL group showed a significantly lower score than the other groups. The mean number of treatments was significantly greater in the fractional laser groups than in the resurfacing laser groups. The resurfacing laser groups had a prolonged recovery period and high risk of complications. The Er:YAG laser caused less erythema or pigmentation compared to the CO2 laser. Although the CO2 laser, Er:YAG laser, and AFL improved the acne scars, the CO2 laser had a greater downtime. Three consecutive AFL treatments are as effective as a single treatment with resurfacing lasers, with shorter social downtime periods and less adverse effects. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wu, Shikai; Xiao, Rongshi
2015-04-01
The effects of laser radiation on the characteristics of the DC tungsten inert gas (TIG) arc were investigated by applying a high power slab CO2 laser and a Yb:YAG disc laser. Experiment results reveal that the arc voltage-current curve shifts downwards, the arc column expands, and the arc temperature rises while the high power CO2 laser beam vertically interacts with the TIG arc in argon. With the increase of the laser power, the voltage-current curve of the arc shifts downwards more significantly, and the closer the laser beam impingement on the arc to the cathode, the more the decrease in arc voltage. Moreover, the arc column expansion and the arc temperature rise occur mainly in the region between the laser beam incident position and the anode. However, the arc characteristics hardly change in the cases of the CO2 laser-helium arc and YAG laser-arc interactions. The reason is that the inverse Bremsstrahlung absorption coefficients are greatly different due to the different electron densities of the argon and helium arcs and the different wave lengths of CO2 and YAG lasers.
Lidar Observations of Atmospheric CO2 Column During 2014 Summer Flight Campaigns
NASA Technical Reports Server (NTRS)
Lin, Bing; Harrison, F. Wallace; Fan, Tai-Fang
2015-01-01
Advanced knowledge in atmospheric CO2 is critical in reducing large uncertainties in predictions of the Earth' future climate. Thus, Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) from space was recommended by the U.S. National Research Council to NASA. As part of the preparation for the ASCENDS mission, NASA Langley Research Center (LaRC) and Exelis, Inc. have been collaborating in development and demonstration of the Intensity-Modulated Continuous-Wave (IM-CW) lidar approach for measuring atmospheric CO2 column from space. Airborne laser absorption lidars such as the Multi-Functional Fiber Laser Lidar (MFLL) and ASCENDS CarbonHawk Experiment Simulator (ACES) operating in the 1.57 micron CO2 absorption band have been developed and tested to obtain precise atmospheric CO2 column measurements using integrated path differential absorption technique and to evaluate the potential of the space ASCENDS mission. This presentation reports the results of our lidar atmospheric CO2 column measurements from 2014 summer flight campaign. Analysis shows that for the 27 Aug OCO-2 under flight over northern California forest regions, significant variations of CO2 column approximately 2 ppm) in the lower troposphere have been observed, which may be a challenge for space measurements owing to complicated topographic condition, heterogeneity of surface reflection and difference in vegetation evapotranspiration. Compared to the observed 2011 summer CO2 drawdown (about 8 ppm) over mid-west, 2014 summer drawdown in the same region measured was much weak (approximately 3 ppm). The observed drawdown difference could be the results of the changes in both meteorological states and the phases of growing seasons. Individual lidar CO2 column measurements of 0.1-s integration were within 1-2 ppm of the CO2 estimates obtained from on-board in-situ sensors. For weak surface reflection conditions such as ocean surfaces, the 1- s integrated signal-to-noise ratio (SNR) of lidar measurements at 11 km altitude reached 376, which was equivalent to a 10-s CO2 error 0.33 ppm. For the entire processed 2014 summer flight campaign data, the mean differences between lidar remote sensed and in-situ estimated CO2 values were about -0.013 ppm. These results indicate that current laser absorption lidar approach could meet space measurement requirements for CO2 science goals.
NASA Astrophysics Data System (ADS)
Cho, Heajin; Lee, Robert C.; Chan, Kenneth H.; Fried, Daniel
2017-02-01
Previous studies have demonstrated that the permeability changes due to the surface modification of dentin can be quantified via thermal imaging during dehydration. The CO2 laser has been shown to remove the smear layer and disinfect root canals. Moreover, thermal modification via CO2 laser irradiation can be used to convert dentin into a highly mineralized enamel-like mineral. The purpose of this study is to evaluate the radicular dentin surface modification after CO2 laser irradiation by measuring the permeability with thermal imaging. Human molar specimens (n=12) were sectioned into 4 axial walls of the pulp chamber and treated with either 10% NaClO for 1 minute, 5% EDTA for 1 minute, CO2 laser or none. The CO2 laser was operated at 9.4 μm with a pulse duration of 26 μs, pulse repetition rate of 300 Hz and a fluence of 13 J/cm2. The samples were dehydrated using an air spray for 60 seconds and imaged using a thermal camera. The resulting surface morphological changes were assessed using 3D digital microscopy. The images from digital microscopy confirmed melting of the mineral phase of dentin. The area enclosed by the time-temperature curve during dehydration, ▵Q, measured with thermal imaging increased significantly with treatments with EDTA and the CO2 laser (P<0.05). These results indicate that the surface modification due to CO2 laser treatment increases permeability of radicular dentin.
Fractional CO2 resurfacing: has it replaced ablative resurfacing techniques?
Duplechain, Jesse Kevin
2013-05-01
The author uses the pulsed ablative CO2 laser regularly for skin rejuvenation. This decision is based on the gold standard status of the CO2 modality and an innovative aftercare treatment shown in the author's practice to greatly reduce the complications of ablative pulsed CO2 laser treatment. Depending on the patient and the severity of the skin condition, the author customizes each treatment, which may also include fractional CO2 lasers, fat grafting, facelifting, or any combination of these techniques. This article presents a detailed description of the evolution of skin rejuvenation with lasers and the current role of lasers as an adjunct to face and necklift surgery. Copyright © 2013 Elsevier Inc. All rights reserved.
The stability of the active medium of RF-exited CO2 lasers with gold as catalyst
NASA Astrophysics Data System (ADS)
Cherezov, V. M.; Novgorodov, M. Z.; Ochkin, V. N.; Samorodov, V. G.; Shishkanov, E. F.; Stepanov, V. A.; Witteman, W. J.
Using mass-spectrometric investigations the gas composition of the active medium of sealed-off cw RF-excited CO2 waveguide lasers have been studied. It has been found that a low degree of CO2 dissociation and a laser power improvement can be achieved by means of a gold catalyst in the laser discharge volume. The conditions for long operational lifetimes of these lasers are described.
Eddy Covariance measurements of stable CO2 and H2O isotopologues
NASA Astrophysics Data System (ADS)
Braden-Behrens, Jelka; Knohl, Alexander
2015-04-01
The analysis of the stable isotope composition of CO2 and H2O fluxes (such as 13C, 18O and 2H in H2O and CO2) has provided valuable insights into ecosystem gas exchange. The approach builds on differences in the isotope signature of different ecosystem components that are primarily caused by the preference for or the discrimination against respective isotope species by important processes within the ecosystem (e.g. photosynthesis or leaf water diffusion). With the ongoing development of laser spectrometric methods, fast and precise measurements of isotopologue mixing ratios became possible, hence also enabling Eddy Covariance (EC) based approaches to directly measure the isotopic composition of CO2 and H2Ov net fluxes on ecosystem scale. During an eight month long measurement campaign in 2015, we plan to simultaneously measure CO2 and H2Ov isotopologue fluxes using an EC approach in a managed beech forest in Thuringia, Germany. For this purpose, we will use two different laser spectrometers for high frequency measurements of isotopic compositions: For H2Ov measurements, we will use an off axis cavity output water vapour isotope analyser (WVIA, Los Gatos Research Inc.) with 5 Hz response; and for CO2 measurements, we will use a quantum cascade laser-based system (QCLAS, Aerodyne Research Inc.) with thermoelectrically cooled detectors and up to 10 Hz measurement capability. The resulting continuous isotopologue flux measurements will be accompanied by intensive sampling campaigns on the leaf scale: Water from leaf, twig, soil and precipitation samples will be analysed in the lab using isotope ratio mass spectrometry. During data analysis we will put a focus on (i) the influence of carbon and oxygen discrimination on the isotopic signature of respective net ecosystem exchange, (ii) on the relationship between evapotranspiration and leaf water enrichment, and (iii) on the 18O exchange between carbon dioxide and water. At present, we already carried out extensive instrument performance tests for both laser spectrometers that will be presented here. In addition, we will present the instrumentation, the measurement periphery as well as anticipated analysis approaches required for the planned measurement campaign.
Clinical application of CO2 laser in periodontal treatment
NASA Astrophysics Data System (ADS)
Hayase, Yasuhiro
1994-09-01
CO2 lasers in particular are expected to have many dental applications because the CO2 laser beam exhibits strong tissue transpirative actions, such as instant coagulation, carbonization, and vaporization, and because its wavelength at 10.6 micrometers is fully absorbed by water so that the ability to make precise incisions with a high degree of safety is excellent, without damaging the deep tissues. However, clinical application of the CO2 laser has been slowed since a fiber which can conduct the laser beam to the oral cavity has only recently developed. This new fiber is an extremely flexible fiber with a minimum bending radius of 20 mm and utilizes pulse wave modes that have improved the handling characteristics in the mouth, and this has enabled us to apply the CO2 laser to a variety of periodontal conditions. The aim of this study was to evaluate the effectiveness of CO2 lasers for the early treatment of inflammation and pain relief of acute periodontitis, curettage of periodontal pockets, healing after excision of gingiva, and early improvement of gingivitis.
Laser inscription of pseudorandom structures for microphotonic diffuser applications.
Alqurashi, Tawfiq; Alhosani, Abdulla; Dauleh, Mahmoud; Yetisen, Ali K; Butt, Haider
2018-04-19
Optical diffusers provide a solution for a variety of applications requiring a Gaussian intensity distribution including imaging systems, biomedical optics, and aerospace. Advances in laser ablation processes have allowed the rapid production of efficient optical diffusers. Here, we demonstrate a novel technique to fabricate high-quality glass optical diffusers with cost-efficiency using a continuous CO2 laser. Surface relief pseudorandom microstructures were patterned on both sides of the glass substrates. A numerical simulation of the temperature distribution showed that the CO2 laser drills a 137 μm hole in the glass for every 2 ms of processing time. FFT simulation was utilized to design predictable optical diffusers. The pseudorandom microstructures were characterized by optical microscopy, Raman spectroscopy, and angle-resolved spectroscopy to assess their chemical properties, optical scattering, transmittance, and polarization response. Increasing laser exposure and the number of diffusing surfaces enhanced the diffusion and homogenized the incident light. The recorded speckle pattern showed high contrast with sharp bright spot free diffusion in the far field view range (250 mm). A model of glass surface peeling was also developed to prevent its occurrence during the fabrication process. The demonstrated method provides an economical approach in fabricating optical glass diffusers in a controlled and predictable manner. The produced optical diffusers have application in fibre optics, LED systems, and spotlights.
10-year experience of CO2-laser application in ambulance gynecology
NASA Astrophysics Data System (ADS)
Stachanov, Michael L.; Masychev, Victor I.; Velsher, Leonid Z.; Kirkin, Vladimir V.; Zhashkov, Roman V.; Kocharian, Emilia A.
2000-10-01
CO2-laser surgical systems have come to stay in everyday practice of modern physicians and are successfully used in colposcopic and laparoscopic surgery. Results, obtained in ambulance gynecology are especially impressing. CO2- laser provides high medical- and cost-effective treatment. Presented work describes many-years experience of CO2- laser application. 439 patients with various vulvaric and cervix diseases were operated within this period. Laser beam parameters were selected according to requirements ((tau)
González-Rodríguez, Alberto; de Dios López-González, Juan; del Castillo, Juan de Dios Luna; Villalba-Moreno, Juan
2011-05-01
Various authors have reported more effective fluoridation from the use of lasers combined with topical fluoride than from conventional topical fluoridation. Besides the beneficial effect of lasers in reducing the acid solubility of an enamel surface, they can also increase the uptake of fluoride. The study objectives were to compare the action of CO(2) and GaAlAs diode lasers on dental enamel and their effects on pulp temperature and enamel fluoride uptake. Different groups of selected enamel surfaces were treated with amine fluoride and irradiated with CO(2) laser at an energy power of 1 or 2 W or with diode laser at 5 or 7 W for 15 s each and compared to enamel surfaces without treatment or topical fluoridated. Samples were examined by means of environmental scanning electron microscopy (ESEM). Surfaces of all enamel samples were then acid-etched, measuring the amount of fluoride deposited on the enamel by using a selective ion electrode. Other enamel surfaces selected under the same conditions were irradiated as described above, measuring the increase in pulp temperature with a thermocouple wire. Fluorination with CO(2) laser at 1 W and diode laser at 7 W produced a significantly greater fluoride uptake on enamel (89 ± 18 mg/l) and (77 ± 17 mg/l) versus topical fluoridation alone (58 ± 7 mg/l) and no treatment (20 ± 1 mg/l). Diode laser at 5 W produced a lesser alteration of the enamel surface compared to CO(2) laser at 1 W, but greater pulp safety was provided by CO(2) laser (ΔT° 1.60° ± 0.5) than by diode laser (ΔT° 3.16° ± 0.6). Diode laser at 7 W and CO(2) laser at 2 W both caused alterations on enamel surfaces, but great pulp safety was again obtained with CO(2) (ΔT° 4.44° ± 0.60) than with diode (ΔT° 5.25° ± 0.55). Our study demonstrates that CO(2) and diode laser irradiation of the enamel surface can both increase fluoride uptake; however, laser energy parameters must be carefully controlled in order to limit increases in pulpal temperature and alterations to the enamel surface.
Comparing mechanical effects and sound production of KTP, thulium, and CO2 laser in stapedotomy.
Kamalski, Digna M A; Verdaasdonk, Rudolf M; de Boorder, Tjeerd; Vincent, Robert; Versnel, Huib; Grolman, Wilko
2014-08-01
The mechanical and acoustic effects that occur during laser-assisted stapedotomy differ among KTP, CO2, and thulium lasers. Making a fenestration in stapedotomy with a laser minimizes the risk of a floating footplate caused by mechanical forces. Theoretically, the lasers used in stapedotomy could inflict mechanical trauma because of absorption in the perilymph, causing vaporization bubbles. These bubbles can generate a shock wave, when imploding. In an inner ear model, we made a fenestration in a fresh human stapes with KTP, CO2, and thulium laser. During the fenestration, we performed high-speed imaging from different angles to capture mechanical effects. The sounds produced by the fenestration were recorded simultaneously with a hydrophone; these recordings were compared with acoustics produced by a conventional microburr fenestration. KTP laser fenestration showed little mechanical effects, with minimal sound production. With CO2 laser, miniscule bubbles arose in the vestibule; imploding of these bubbles corresponded to the acoustics. Thulium laser fenestration showed large bubbles in the vestibule, with a larger sound production than the other two lasers. Each type of laser generated significantly less noise than the microburr. The microburr maximally reached 95 ± 7 dB(A), compared with 49 ± 8 dB(A) for KTP, 68 ± 4 dB(A) for CO2, and 83 ± 6 dB(A) for thulium. Mechanical and acoustic effects differ among lasers used for stapedotomy. Based on their relatively small effects, KTP and CO2 lasers are preferable to thulium laser.
Laser detection of CO2 concentration in human breath at various diseases
NASA Astrophysics Data System (ADS)
Ageev, Boris G.; Nikiforova, Olga Y.
2015-12-01
Absorption spectra of human breath in 10 μm region were recorded by the use of intracavity laser photo-acoustic gas analyzer based on tunable waveguide CO2 laser. Healthy persons and patients with various diseases were studied. For determination of CO2 concentration in exhalation samples gas analyzer was calibrated by reference gaseous mixture CO2-N2. It was obtained that CO2 concentration values in human breath of healthy persons are greater than that of patients with various diseases.
Diaz, E C; Lindgren, B W; Gong, E M
2014-12-01
Demonstrate and report initial results using a carbon dioxide (CO2) laser for detrusor tunnel creation in robot-assisted laparoscopic extravesical ureteral reimplant (RALUR). Retrospective chart review was performed for cases of RALUR from 2011 to 2014. Patients undergoing complex reconstruction (ureteral tailoring, dismembered reimplant, concomitant ureteroureterostomy), and those who had incomplete follow-up were excluded. Variables, including use of the CO2 laser, were collected and correlated with outcomes. 23 patients representing 40 ureteral units were included for analysis. A CO2 laser was used in 9/23 (39%) patients and 16/40 (40%) ureteral units. Intraoperative mucosotomy was reported in 3/14 (21%) patients for the electrocautery group and 1/9 (11%) patients for the CO2 laser group. Resolution of VUR was observed in 11/14 (79%), and 9/9 (100%) of patients for the electrocautery group and the CO2 laser group, respectively. Two complications were identified in the electrocautery group of patients: ileus (Clavien 2), and transient bilateral ureteral obstruction requiring placement of ureteral stents (Clavien 3B). There were no complications in the CO2 laser group. Creation of the detrusor tunnel with a CO2 laser is safe and effective, and is associated with a lower rate of failure and complication in this cohort. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Hsu, Tuan-Ti; Yeh, Chia-Hung; Kao, Chia-Tze; Chen, Yi-Wen; Huang, Tsui-Hsien; Yang, Jaw-Ji; Shie, Ming-You
2015-07-01
Mineral trioxide aggregate (MTA) has been successfully used in clinical applications in endodontics. Studies show that the antibacterial effects of CO2 laser irradiation are highly efficient when bacteria are embedded in biofilm because of a photothermal mechanism. The aim of this study was to confirm the effects of CO2 laser irradiation on MTA with regard to both material characterization and cell viability. MTA was irradiated with a dental CO2 laser using directly mounted fiber optics in the wound healing mode with a spot area of 0.25 cm(2) and then stored in an incubator at 100% relative humidity and 37°C for 1 day to set. The human dental pulp cells cultured on MTA were analyzed along with their proliferation and odontogenic differentiation behaviors. The results indicate that the setting time of MTA after irradiation by the CO2 laser was significantly reduced to 118 minutes rather than the usual 143 minutes. The maximum diametral tensile strength and x-ray diffraction patterns were similar to those obtained without CO2 laser irradiation. However, the CO2 laser irradiation increased the amount of Ca and Si ions released from the MTA and regulated cell behavior. CO2 laser-irradiated MTA promoted odontogenic differentiation of hDPCs, with the increased formation of mineralized nodules on the substrate's surface. It also up-regulated the protein expression of multiple markers of odontogenic and the expression of dentin sialophosphoprotein protein. The current study provides new and important data about the effects of CO2 laser irradiation on MTA with regard to the decreased setting time and increased ion release. Taking cell functions into account, the Si concentration released from MTA with laser irradiation may be lower than a critical value, and this information could lead to the development of new regenerative therapies for dentin and periodontal tissue. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Vachiramon, Vasanop; Panmanee, Wikanda; Techapichetvanich, Thanya; Chanprapaph, Kumutnart
2016-04-01
Solar lentigines are benign pigmented lesions that occur mostly on sun-exposed areas. Q-switched and ablative lasers are effective for removing these lesions but the high incidence of postinflammatory hyperpigmentation raises concern in darker skin types. The objective of this study is to compare the efficacy and degree of postinflammatory hyperpigmentation with the Q-switched Nd:YAG and fractional carbon dioxide (CO2 ) laser for treatment of solar lentigines in Asians. Twenty-five Thai patients (skin phototype III-IV) with at least two lesions of solar lentigines on upper extremities were enrolled in this study. Two lesions were randomly selected for the treatment with a single session of Q-switched Nd:YAG or fractional CO2 laser. Outcomes were evaluated using physician grading scale, colorimeter, and patient self-assessment at 6 and 12 weeks after treatment. Side effects were recorded. A total of 532 nm Q-switched Nd:YAG laser showed significant improvement of pigmentation over fractional CO2 laser at 6th and 12th week by both colorimeter assessment and physician grading scale (P < 0.05). No significant difference in postinflammatory hyperpigmentation from both lasers was observed. In terms of patient self-assessment, 80% of the patients treated with 532 nm Q-switched Nd:YAG laser had excellent results compared to 8% in fractional CO2 laser group. However, fractional CO2 laser treatment had faster healing time and less pain score compared to Q-switched Nd:YAG laser. Q-switched Nd:YAG is superior to fractional CO2 laser for treatment of solar lentigines but requires longer healing time and produces more pain. The incidence of postinflammatory hyperpigmentation was not significantly different with both lasers. Further studies are needed to obtain the proper parameter and the treatment frequency of fractional CO2 laser in solar lentigines. © 2016 Wiley Periodicals, Inc.
Fractional CO2 laser treatment for vaginal laxity: A preclinical study.
Kwon, Tae-Rin; Kim, Jong Hwan; Seok, Joon; Kim, Jae Min; Bak, Dong-Ho; Choi, Mi-Ji; Mun, Seok Kyun; Kim, Chan Woong; Ahn, Seungwon; Kim, Beom Joon
2018-05-07
Various studies have investigated treatment for vaginal laxity with microablative fractional carbon dioxide CO 2 laser in humans; however, this treatment has not yet been studied in an animal model. Herein, we evaluate the therapeutic effects of fractional CO 2 laser for tissue remodeling of vaginal mucosa using a porcine model, with the aim of improving vaginal laxity. The fractional CO 2 laser enables minimally invasive and non-incisional procedures. By precisely controlling the laser energy pulses, energy is sent to the vaginal canal and the introitus area to induce thermal denaturation and contraction of collagen. We examined the effects of fractional CO 2 laser on a porcine model via clinical observation and ultrasound measurement. Also, thermal lesions were histologically examined via hematoxylin-eosin staining, Masson's trichrome staining, and Elastica van Gieson staining and immunohistochemistry. The three treatment groups, which were determined according to the amount of laser-energy applied (60, 90, and 120 mJ), showed slight thermal denaturation in the vaginal mucosa, but no abnormal reactions, such as excessive hemorrhaging, vesicles, or erythema, were observed. Histologically, we also confirmed that the denatured lamina propria induced by fractional CO 2 laser was dose-dependently increased after laser treatment. The treatment groups also showed an increase in collagen and elastic fibers due to neocollagenesis and angiogenesis, and the vaginal walls became firmer and tighter because of increased capillary and vessel formation. Also, use of the fractional CO 2 laser increased HSP (heat shock protein) 70 and collagen type I synthesis. Our results show that microablative fractional CO 2 laser can produce remodeling of the vaginal connective tissue without causing damage to surrounding tissue, and the process of mucosa remodeling while under wound dressings enables collagen to increase and the vaginal wall to become thick and tightened. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
Computer modeling of pulsed CO2 lasers for lidar applications
NASA Technical Reports Server (NTRS)
Spiers, Gary D.
1993-01-01
The object of this effort is to develop code to enable the accurate prediction of the performance of pulsed transversely excited (TE) CO2 lasers prior to their construction. This is of particular benefit to the NASA Laser Atmospheric Wind Sounder (LAWS) project. A benefit of the completed code is that although developed specifically for the pulsed CO2 laser much of the code can be modified to model other laser systems of interest to the lidar community. A Boltzmann equation solver has been developed which enables the electron excitation rates for the vibrational levels of CO2 and N2, together with the electron ionization and attachment coefficients to be determined for any CO2 laser gas mixture consisting of a combination of CO2, N2, CO, He and CO. The validity of the model has been verified by comparison with published material. The results from the Boltzmann equation solver have been used as input to the laser kinetics code which is currently under development. A numerical code to model the laser induced medium perturbation (LIMP) arising from the relaxation of the lower laser level has been developed and used to determine the effect of LIMP on the frequency spectrum of the LAWS laser output pulse. The enclosed figures show representative results for a laser operating at 0.5 atm. with a discharge cross-section of 4.5 cm to produce a 20 J pulse with aFWHM of 3.1 microns. The first four plots show the temporal evolution of the laser pulse power, energy evolution, LIMP frequency chirp and electric field magnitude. The electric field magnitude is taken by beating the calculated complex electric field and beating it with a local oscillator signal. The remaining two figures show the power spectrum and energy distribution in the pulse as a function of the varying pulse frequency. The LIMP theory has been compared with experimental data from the NOAA Windvan Lidar and has been found to be in good agreement.
Frega, Antonio; Schimberni, Mauro; Ralli, Eleonora; Verrone, Antonella; Manzara, Federica; Schimberni, Matteo; Nobili, Flavia; Caserta, Donatella
2016-08-01
The treatment of Bartholin's gland cysts by traditional surgery is characterized by some disadvantages and complications such as hemorrhage, postoperative dyspareunia, infections, necessity for a general anesthesia. Contrarily, CO2 laser surgery might be less invasive and more effective as it solves many problems of traditional surgery. The aim of our study is to describe CO2 laser technique evaluating its feasibility, complication rate and results vs traditional surgery. Among patients treated for Bartholin's gland cyst, we enrolled 62 patients comparing traditional surgical excision vs CO2 laser surgery of whom 27 patients underwent traditional surgery, whereas 35 patients underwent CO2 laser surgery. Mean operative time, complication rate, recurrence rate and short- and long-term outcomes were assessed. The procedures required a mean operative time of 9 ± 5.3 min for CO2 laser surgery and 42.2 ± 13.8 for traditional surgery. Two patients (5.7 %) needed an hemostatic suture for intraoperative bleeding in the laser CO2 laser technique against 14.8 % for traditional surgery. Carbon dioxide allows a complete healing in a mean time of 22 days without scarring, hematomas or wound infections and a return to daily living in a mean time of 2 days. Instead, patients undergone traditional surgery required a mean time of 14 days to return to daily life with a healing mean time completed in 28 days. The minimum rate of intra- and post-operative complications, the ability to perform it under local anesthesia in an outpatient setting make CO2 laser surgery more cost-effective than traditional surgery.
Review of Laser Ablation Process for Single Wall Carbon Nanotube Production
NASA Technical Reports Server (NTRS)
Arepalli, Sivaram
2003-01-01
Different types of lasers are now routinely used to prepare single wall carbon nanotubes (SWCNTs). The original method developed by researchers at Rice University utilized a "double pulse laser oven" process. A graphite target containing about 1 atomic percent of metal catalysts is ablated inside a 1473K oven using laser pulses (10 ns pulse width) in slow flowing argon. Two YAG lasers with a green pulse (532 nm) followed by an IR pulse (1064 nm) with a 50 ns delay are used for ablation. This set up produced single wall carbon nanotube material with about 70% purity having a diameter distribution peaked around 1.4 nm. The impurities consist of fullerenes, metal catalyst clusters (10 to 100 nm diameter) and amorphous carbon. The rate of production with the initial set up was about 60 mg per hour with 10Hz laser systems. Several researchers have used variations of the lasers to improve the rate, consistency and study effects of different process parameters on the quality and quantity of SWCNTs. These variations include one to three YAG laser systems (Green, Green and IR), different pulse widths (nano to microseconds as well as continuous) and different laser wavelengths (Alexandrite, CO, CO2, free electron lasers in the near to far infrared). It is noted that yield from the single laser (Green or IR) systems is only a fraction of the two laser systems. The yield seemed to scale up with the repetition rate of the laser systems (10 to 60 Hz) and depended on the beam uniformity and quality of the laser pulses. The shift to longer wavelength lasers (free electron, CO and CO2) did not improve the quality, but increased the rate of production because these lasers are either continuous (CW) or high repetition rate pulses (kHz to MHz). The average power and the peak power of the lasers seem to influence the yields. Very high peak powers (MegaWatts per square centimeter) are noted to increase ablation of bigger particles with reduced yields of SWCNTs. Increased average powers seem to help the conversion of the carbon from target into vapor phase to improve formation of nanotubes. The use of CW far infrared lasers reduced the need for the oven, at the expense of controlled ablation. Some of these variations are tried with different combinations and concentrations of metal catalysts (Nickel with Cobalt, Iron, Palladium and Platinum) different buffer gases (e.g. Helium); with different oven temperatures (Room temperature to 1473K); under different flow conditions (1 to 1000 kPa) and even different porosities of the graphite targets. It is to be noted that the original Cobalt and Nickel combination worked best, possibly because of improved carbonization with stable crystalline phases. The mean diameter and yield seemed to increase with increasing oven temperatures. Thermal conductivity of the buffer gas and flow conditions dictate the quality as well as quantity of the SWCNTs. Faster flows, lower pressures and heavier gases seem to increase the yields. This review will attempt to cover all these variations and their relative merits. Possible growth mechanisms under these different conditions will also be discussed.
Threshold analysis of pulsed lasers with application to a room-temperature Co:MgF2 laser
NASA Technical Reports Server (NTRS)
Harrison, James; Welford, David; Moulton, Peter F.
1989-01-01
Rate-equation calculations are used to model accurately the near-threshold behavior of a Co:MgF2 laser operating at room temperature. The results demonstrate the limitations of the conventional threshold analysis in cases of practical interest. This conclusion is applicable to pulsed solid-state lasers in general. The calculations, together with experimental data, are used to determine emission cross sections for the Co:MgF2 laser.
Controlling chaotic behavior in CO2 and other lasers
NASA Astrophysics Data System (ADS)
1993-06-01
Additional substantial experimental progress has been made, in the third month of the project, in setting up equipment and testing for producing chaotic behavior with a CO2 laser. The project goal is to synchronize and control chaos in CO2 and other lasers, and thereby increase the power in ensembles of coupled laser sources. Numerous investigations into the chaos regime have been made, a second CO2 laser has been brought on stream, and work is progressing in the fourth month toward coupling the two lasers and control of the first laser. It is also intended to submit at least two papers to the Second Experimental Chaos Conference which is supported by the Office of Naval Research. Abstracts to those two papers are attached. Last month's report discussed the experimental investigation of nonlinear dynamics of CO2 lasers which involved a new technique of inducing chaos. In this new technique, an acoustically modulated feedback of the laser light was used and led to chaotic dynamics at a very low modulation frequency of 375 Hz. Since then, new results have been obtained by an Electro-Optical Modulation (EOM) technique. In the new setup, the electro-optical modulator is placed in an external cavity outside the laser.
Real time, ambient air laser monitor for rare CO2 isotopic tracers: Δ13 C18 O16 O and Δ17 O
NASA Astrophysics Data System (ADS)
Nelson, David; Shorter, Joanne; McManus, Barry; Jervis, Dylan; Zahniser, Mark; Ono, Shuhei
2017-04-01
Greenhouse gas (GHG) emissions are the primary drivers of global climate change and hence there is a crucial need to quantify their sources and sinks. A powerful technique to help constrain source and sink strengths in GHG exchange processes is the analysis of the relative proportions of isotopic variants of GHGs. We present a new laser isotope monitor based on Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) to measure the primary clumped isotopologue of CO2 (Δ13 C18 O16 O) and to simultaneously measure the mass independent 17 O-CO2 content (Δ17 O). The instrument directly measures dried atmospheric samples without cryogenic preconcentration of CO2 . The instrument has several novel features. The instrument's sensitivity is enhanced by employing a 400 meter optical absorption cell. Measurement drift is suppressed by using a rapid sample switching method with frequent comparison to a working reference. A new dual-pressure measurement scheme is demonstrated. This scheme solves the dynamic range challenge that arises in simultaneously measuring the main isotopologues of CO2 together with much less abundant clumped isotopologue species. Our initial results address measurement precision, measurement drift and calibration. We show the potential to reach 0.03 per mil repeatability with time resolution of 3 minutes and with minimal drift over an 18 hour measurement period. The instrument is sufficiently compact to be field deployed thus providing the possibility of continuous measurements of Δ13 C18 O16 O and Δ17 O rather than occasional flask samples.
Comparison of ultrasonic and CO₂laser pretreatment methods on enzyme digestibility of corn stover.
Tian, Shuang-Qi; Wang, Zhen-Yu; Fan, Zi-Luan; Zuo, Li-Li
2012-01-01
To decrease the cost of bioethanol production, biomass recalcitrance needs to be overcome so that the conversion of biomass to bioethanol becomes more efficient. CO(2) laser irradiation can disrupt the lignocellulosic physical structure and reduce the average size of fiber. Analyses with Fourier transform infrared spectroscopy, specific surface area, and the microstructure of corn stover were used to elucidate the enhancement mechanism of the pretreatment process by CO(2) laser irradiation. The present work demonstrated that the CO(2) laser had potential to enhance the bioconversion efficiency of lignocellulosic waste to renewable bioethanol. The saccharification rate of the CO(2) laser pretreatment was significantly higher than ultrasonic pretreatment, and reached 27.75% which was 1.34-fold of that of ultrasonic pretreatment. The results showed the impact of CO(2) laser pretreatment on corn stover to be more effective than ultrasonic pretreatment.
Treatment of Bartholin gland cyst with CO2 laser
Speck, Neila Maria de Góis; Boechat, Karol Pereira Ruela; dos Santos, Georgia Mouzinho Lima; Ribalta, Julisa Chamorro Lascasas
2016-01-01
ABSTRACT Objective To describe the results of treatment with CO2 laser for Bartholin gland cysts. Methods Thirty-one women with Bartholin gland cysts were treated with CO2 laser at an outpatient´s setting. Skin incision was performed with focused laser beam, the capsule was opened to drain mucoid content, followed by internal vaporization of impaired capsule. Results There were no complications. Five patients had recurrence of the cyst and were submitted to a second and successful session. Conclusion CO2 laser surgery was effective to treat Bartholin gland cysts with minimal or no complications, and can be performed at an outpatient´s setting. PMID:27074230
CO2 laser oscillators for laser radar applications
NASA Technical Reports Server (NTRS)
Freed, C.
1990-01-01
This paper reviews the spectral purity, frequency stability, and long-term stabilization of newly developed CO2 isotope lasers. Extremely high spectral purity, and short-term stability of less than 1.5 x 10 to the -13th have been achieved. A brief description on using CO2 isotope lasers as secondary frequency standards and in optical radar is given. The design and output characteristics of a single frequency, TEM00q mode, variable pulse width, hybrid TE CO2 laser system is also described. The frequency chirp in the output has been measured and almost completely eliminated by means of a novel technique.
NASA Astrophysics Data System (ADS)
Prokhorov, Ivan; Kluge, Tobias; Janssen, Christof
2016-04-01
Precise clumped isotopes analysis of carbon dioxide opens up new horizons of atmospheric and biogeochemical research. Recent advances in laser and spectroscopic techniques provides us necessary instrumentation to access extremely low sub-permill variations of multiply-substituted isotopologues. We present an advanced analysis method of carbon dioxide clumped isotopes using direct absorption spectroscopy. Our assessments predict the ultimate precision of the new method on the sub-permill level comparable to state of the art mass spectrometry. Among the most auspicious intrinsic properties of this method we highlight genuine Δ16O13C18O and Δ16O13C18O measurements without isobaric interference, measurement cycle duration of several minutes versus hours for mass spectrometric analysis, reduced sample size of ˜ 10 μmol and high flexibility, allowing us to perform in-situ measurements. The pilot version of the instrument is being developed in an international collaboration framework between Heidelberg University, Germany and Pierre and Marie Curie University, Paris, France. It employs two continuous interband quantum cascade lasers tuned at 4.439 μm and 4.329 μm to measure doubly ( 16O13C18O, 16O13C17O) and singly ( 16O12C16O, 16O13C16O, 16O12C17O, 16O12C18O) substituted isotopologues, respectively. Two identical Herriot cells are filled with dry pure CO2 sample and reference gas at working pressure of 1 - 10 mbar. Cells provide optical path lengths of ˜ 17 m for the laser tuned at doubly substituted isotopologues lines and use a single pass for the laser tuned at the stronger lines of singly substituted isotopologues. Light outside of the gas cells is coupled into optical fiber to avoid absorption by ambient air CO2. Simulations predict sub-permill precision at working pressure of 1 mbar and room temperature stabilised at the ±10 mK level. Our prime target is to apply the proposed method for continuous in-situ analysis of CO2. We are foreseeing potential applications to the following environmental issues: assessments of distinct sources of atmospheric CO2, temperature reconstructions from terrestrial and marine archives, extra-terrestrial atmosphere studies, etc.
Yaaghoobian, Barmak; Sadeghi-Ghyassi, Fatemeh; Hajebrahimi, Sakineh
2017-01-01
Background and aims Skin rejuvenation is one of high demand cosmetic interventions in Iran. Fractional CO2 Laser is a high power ablative laser which has variety of utilization in medicine including treatment of acne scars and rejuvenation. The aim of this study was to evaluate the safety, efficacy, and cost-effectiveness of Fractional CO2 Laser in comparison with other methods of rejuvenation and acne scar treatment. Methods A systematic database search including Medline (via OVID and PubMed), EMBASE, CINHAL, Cochrane Library, CRD, SCOPUS and Web of Science conducted. After screening search results, selected publications appraised by CASP and Cochrane Collaboration's tool for assessing risk of bias and eligible studies included in the systematic review. In economic evaluation, all costs and benefits analyzed from Iran ministry of health's perspective. Results From 2667 publications, two randomized control trials were eligible and included in the study. The affectivity and complications of Fractional CO2 laser were comparable with Er: YAG but Fractional CO2 laser was 14.7% (P=0.01) more effective than Q-Switched ND: YAG laser. Cost affectivity of this method was the same as other alternative lasers. Conclusions Fractional CO2 laser is an effective and safe method for curing several kinds of skin. Never the less there was not sufficient evidence to support its advantage. This device has equal or lower price in comparison to competent technologies except for the non- fractional ablative Co2 laser that has the same or lower price and comparable effects.
Low-Temperature CO-Oxidation Catalysts for Long-Life CO2 Lasers
NASA Technical Reports Server (NTRS)
Schryer, David R. (Editor); Hoflund, Gar B. (Editor)
1990-01-01
Low-temperature CO-oxidation catalysts are necessary for closed-cycle pulsed CO2 lasers as well as for other applications, including air purification. The papers presented in this volume discuss several such catalysts, including information on catalyst preparation, techniques for enhancing catalyst performance, laboratory and laser test results, and mechanistic considerations.
CO2 laser induced refractive index changes in optical polymers.
Liu, Qing; Chiang, Kin Seng; Reekie, Laurence; Chow, Yuk Tak
2012-01-02
We study the infrared photosensitivity properties of two optical polymer materials, benzocyclobutene (BCB) and epoxy OPTOCAST 3505, with a 10.6 μm CO2 laser. We discover that the CO2 laser radiation can lower the refractive index of BCB by as much as 5.5 × 10(-3), while inducing no measurable index change in the epoxy. As confirmed by Fourier transform infrared spectroscopy, the observed index change in BCB can be attributed to photothermal modification of chemical bonds in the material by the CO2 laser radiation. Our findings open up a new possibility of processing polymer materials with a CO2 laser, which could be further developed for application in the areas of post-processing and direct-writing of polymer waveguide devices.
NASA Astrophysics Data System (ADS)
Shukla, P. P.; Lawrence, J.
2011-02-01
The fracture toughness property ( K1C) of Si 3N 4 and ZrO 2 engineering ceramics was investigated by means of CO 2 and a fibre laser surface treatment. Near surface modifications in the hardness were investigated by employing the Vickers indentation method. Crack lengths and the crack geometry were then measured by using the optical microscopy. A co-ordinate measuring machine was used to investigate the diamond indentations and to measure the lengths of the cracks. Thereafter, computational and analytical methods were employed to determine the K1C. An increase in the K1C of both ceramics was found by the CO 2 and the fibre laser surface treatment in comparison to the as-received surfaces. The K1C of the CO 2 laser radiated surface of the Si 3N 4 was over 3% higher in comparison to that of the fibre laser treated surface. This was by softening of the near surface layer of the Si 3N 4 which comprised of lowering of hardness, which in turn increased the crack resistance. The effects were not similar in ZrO 2 ceramic to that of the Si 3N 4 as the fibre laser radiation in this case had produced an increase of 34% compared to that of the CO 2 laser radiation. This occurred due to propagation of lower crack resulting from the Vickers indentation test during the fibre laser surface treatment which inherently affected the end K1C through an induced compressive stress layer. The K1C modification of the two ceramics treated by the CO 2 and the fibre laser was also believed to be influenced by the different laser wavelength and its absorption co-efficient, the beam delivery system as well as the differences in the brightness of the two lasers used.
NASA Astrophysics Data System (ADS)
Abshire, J. B.; Riris, H.; Allan, G. R.; Weaver, C.; Mao, J.; Hasselbrack, W.
2009-04-01
Accurate measurements of tropospheric CO2 abundances with global-coverage are needed to quantify processes that regulate CO2 exchange with the land and oceans. The 2007 Decadal Survey for Earth Science by the US National Research Council recommended a space-based CO2 measuring mission called ASCENDS. We have been developing a technique for the remote measurement of tropospheric CO2 concentrations from aircraft and as a candidate for the ASCENDS mission. It uses the 1570-nm CO2 band and a dual channel laser absorption spectrometer (ie DIAL used in altimeter mode). It uses several tunable laser transmitters allowing simultaneous measurement of the absorption from a CO2 absorption line in the 1570 nm band, O2 extinction in the oxygen A-band, and surface height and aerosol backscatter in the same path. It directs the narrow co-aligned laser beams toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. During the measurement, the lasers are stepped in wavelength across the CO2 line and an O2 line (near 765 nm) at a ~ 1 kHz rate. The receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. We use pulsed laser signals and time gating to isolate the laser echo signals from the surface, and to reject photons scattered from thin clouds and aerosols in the path. Previously we had constructed breadboard versions of our CO2 and O2 sensors, using tunable diode lasers, fiber laser amplifiers and 20 cm diameter telescopes. We have used them to make measurements of gas absorptions over 0.2, 0.4 and 1.3 km long outdoor paths. We also have also calculated several characteristics of the technique for space and have performed an initial space mission accommodation study. During 2008 we reconfigured our lidar for airborne use and made measurements of atmospheric CO2 absorption in the nadir column from the aircraft to the surface during 5 flights. The airborne lidar sweeps the laser wavelength across the CO2 line in either 10 or 20 steps per measurement. The line scan rate is ~ 1 KHz and the laser pulse widths are 1 usec. The time resolved laser backscatter is collected by the telescope and detected by a photomultiplier and recorded by a photon counting timing system. We installed our lidar on the NASA Glenn Lear-25 aircraft in October and first made measurements using the 1571.4 nm CO2 absorption line while flying in northern Ohio. We made laser backscatter and absorption measurements over a variety of land surface types, water surfaces and through thin clouds, broken clouds and to cloud tops. Strong laser signals were observed at altitudes from 2.5 to 11 km on two flights. We completed three additional flights during December 2008 and gathered over 6 hours of atmospheric CO2 column measurements using the 1572.02 and 1572.33 nm CO2 lines. Airborne CO2 line shape and absorption measurements were made while flying at 3-11 km altitudes over southwestern Ohio. Subsequently two flights were made from Ponca City OK, just east of the US Department of Energy's (DOE) ARM site. We made 4 hours of airborne measurements in square patterns around the ARM site at altitudes from 3-8 km. The increased CO2 line absorptions at higher altitudes were evident in all flights. The December flights were also coordinated with DOE investigators who flew an in-situ CO2 sensor on a Cessna aircraft inside the CO2 sounder's flight pattern. These yielded two height resolved profiles of CO2 concentrations from 5 km to the surface, which are being analyzed with radiosonde measurements for comparisons. More details of the flights, measurements and their analysis will be described in the presentation.
Laser plasmatron for diamond coating deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glova, A. F., E-mail: afglova@triniti.ru; Lysikov, A. Yu.; Malyuta, D. D.
2016-12-15
An experimental installation with a laser plasmatron based on a continuous wave CO{sub 2} laser with a radiation power of up to 3.5 kW has been created. The plasmatron design makes it possible to bring out the plasma jet into atmospheric air both along and across the laser beam direction. The spatial temperature distributions on the metal substrate surface heated by the plasma jet are measured. The threshold power for optical discharge maintenance as a function of the gas flow rate and the focal length of the focusing lens are obtained for an Ar and Ar/CH{sub 4}/H{sub 2} gas mixturemore » under atmospheric pressure; the radiation spectrum of the discharge plasma is measured. A one-dimensional model of the discharge for estimation of its geometrical parameters in a convergent laser beam with consideration of radiation refraction on the discharge is given.« less
Diode-pumped 1.5-1.6 μm laser operation in Er³⁺ doped YbAl₃(BO₃)₄ microchip.
Chen, Yujin; Lin, Yanfu; Zou, Yuqi; Huang, Jianhua; Gong, Xinghong; Luo, Zundu; Huang, Yidong
2014-06-02
Er3+ doped YbAl3(BO3)4 crystal with large absorption coefficient of 184 cm(-1) at pump wavelength of 976 nm is a promising microchip gain medium of 1.5-1.6 μm laser. End-pumped by a 976 nm diode laser, 1.5-1.6 μm continuous-wave laser with maximum output power of 220 mW and slope efficiency of 8.1% was obtained at incident pump power of 4.54 W in a c-cut 200-μm-thick Er:YbAl3(BO3)4 microchip. When a Co2+:Mg0.4Al2.4O4 crystal was used as the saturable absorber, 1521 nm passively Q-switched pulse laser with about 0.19 μJ energy, 265 ns duration, and 96 kHz repetition rate was realized.
BESTIA - the next generation ultra-fast CO 2 laser for advanced accelerator research
Pogorelsky, Igor V.; Babzien, Markus; Ben-Zvi, Ilan; ...
2015-12-02
Over the last two decades, BNL’s ATF has pioneered the use of high-peak power CO 2 lasers for research in advanced accelerators and radiation sources. In addition, our recent developments in ion acceleration, Compton scattering, and IFELs have further underscored the benefits from expanding the landscape of strong-field laser interactions deeper into the mid-infrared (MIR) range of wavelengths. This extension validates our ongoing efforts in advancing CO 2 laser technology, which we report here. Our next-generation, multi-terawatt, femtosecond CO 2 laser will open new opportunities for studying ultra-relativistic laser interactions with plasma in the MIR spectral domain, including new regimesmore » in the particle acceleration of ions and electrons.« less
Frequency Stabilization of DFB Laser Diodes at 1572 nm for Spaceborne Lidar Measurements of CO2
NASA Technical Reports Server (NTRS)
Numata, Kenji; Chen, Jeffrey R.; Wu, Stewart T.; Abshire, James B.; Krainak, Michael A.
2010-01-01
We report a fiber-based, pulsed laser seeder system that rapidly switches among 6 wavelengths across atmospheric carbon dioxide (CO2) absorption line near 1572.3 nm for measurements of global CO2 mixing ratios to 1-ppmv precision. One master DFB laser diode has been frequency-locked to the CO2 line center using a frequency modulation technique, suppressing its peak-to-peak frequency drifts to 0.3 MHz at 0.8 sec averaging time over 72 hours. Four online DFB laser diodes have been offset-locked to the master laser using phase locked loops, with virtually the same sub-MHz absolute accuracy. The 6 lasers were externally modulated and then combined to produce the measurement pulse train.
Circumcision using CO2 laser: report of 860 cases
NASA Astrophysics Data System (ADS)
Chen, Wen B.; Chen, Zi-Fu; Zhan, Tian-qi; Gao, Xiang-Xun; Huang, Chao
1993-03-01
Eight-hundred-sixty cases of circumcision using CO2 laser are reported. The age of patients ranged from 9 - 65 years, with a mean age of 23.8 years. The technique was simple and can be quickly accomplished by a single operator. After local anesthesia the glans penis was protected by a protector. Then, circumcision was performed with a CO2 laser -- HeNe laser combined machine. There was an HeNe laser aiming system in this machine thus the surgeon had a three-dimensional visible indicator of the incision. The focusing CO2 laser beam was used for cutting the prepuce during the operation. There was almost no operative bleeding. All the patients needed no antibiotic postoperatively. Complications were minimal and satisfactory results were achieved.
Heterodyne frequency measurements on N2O at 5.3 and 9.0 microns
NASA Technical Reports Server (NTRS)
Wells, J. S.; Jennings, D. A.; Hinz, A.; Murray, J. S.; Maki, A. G.
1985-01-01
Heterodyne frequency measurements on the 01(1)1-00(0)0 band of N2O have been made with the use of a tunable-diode laser, CO laser transfer oscillator, and a CO2 laser frequency synthesizer. A beat frequency was measured between a CO laser and tunable-diode laser whose frequency was locked to the peak of N2O absorption features. The frequency of the CO laser was simultaneously determined by neasuring the beat frequency with respect to a reference synthesized from two CO2 lasers. New rovibrational constants are given for the 01(1)1 state of N2O, which are in excellent agreement with previous results, although the band center is 4 MHz higher than in the previous measurements. A table for the line frequencies and their absolute uncertainties is given for the N2O absorption lines in the wave-number region from 1830 to 1920 kaysers. Some additional frequency measurements near the lower-frequency end of the 02(0)0-00(0)0 band have also been made with respect to a C-12)(0-18)2 laser.
Fifteen terawatt picosecond CO2 laser system.
Haberberger, D; Tochitsky, S; Joshi, C
2010-08-16
The generation of a record peak-power of 15 TW (45 J, 3 ps) in a single CO(2) laser beam is reported. Using a master oscillator-power amplifier laser system, it is shown that up to 100 J of energy can be extracted in a train of 3 ps laser pulses separated by 18 ps, a characteristic time of the CO(2) molecule. The bandwidth required for amplifying the short injected laser pulse train in a 2.5 atm final CO(2) amplifier is provided by field broadening of the medium at intensities of up to 140 GW/cm(2). The measured saturation energy for 3 ps pulses is 120 mJ/cm(2) which confirms that energy is simultaneously extracted from six rovibrational lines.
Wada, Ryuichi; Matsumi, Yutaka; Nakayama, Tomoki; Hiyama, Tetsuya; Fujiyoshi, Yasushi; Kurita, Naoyuki; Muramoto, Kenichiro; Takanashi, Satoru; Kodama, Naomi; Takahashi, Yoshiyuki
2017-12-01
Isotope ratios of carbon dioxide and water vapour in the near-surface air were continuously measured for one month in an urban area of the city of Nagoya in central Japan in September 2010 using laser spectroscopic techniques. During the passages of a typhoon and a stationary front in the observation period, remarkable changes in the isotope ratios of CO 2 and water vapour were observed. The isotope ratios of both CO 2 and water vapour decreased during the typhoon passage. The decreases can be attributed to the air coming from an industrial area and the rainout effects of the typhoon, respectively. During the passage of the stationary front, δ 13 C-CO 2 and δ 18 O-CO 2 increased, while δ 2 H-H 2 Ov and δ 18 O-H 2 Ov decreased. These changes can be attributed to the air coming from rural areas and the air surrounding the observational site changing from a subtropical air mass to a subpolar air mass during the passage of the stationary front. A clear relationship was observed between the isotopic CO 2 and water vapour and the meteorological phenomena. Therefore, isotopic information of CO 2 and H 2 Ov could be used as a tracer of meteorological information.
Chemical engineering design of CO oxidation catalysts
NASA Technical Reports Server (NTRS)
Herz, Richard K.
1987-01-01
How a chemical reaction engineer would approach the challenge of designing a CO oxidation catalyst for pulsed CO2 lasers is described. CO oxidation catalysts have a long history of application, of course, so it is instructive to first consider the special requirements of the laser application and then to compare them to the characteristics of existing processes which utilize CO oxidation catalysts. All CO2 laser applications require a CO oxidation catalyst with the following characteristics: (1) active at stoichiometric ratios of O2 and CO, (2) no inhibition by CO2 or other components of the laser environment, (3) releases no particulates during vibration or thermal cycling, and (4) long lifetime with a stable activity. In all applications, low consumption of power is desirable, a characteristic especially critical in aerospace applications and, thus, catalyst activity at low temperatures is highly desirable. High power lasers with high pulse repetition rates inherently require circulation of the gas mixture and this forced circulation is available for moving gas past the catalyst. Low repetition rate lasers, however, do not inherently require gas circulation, so a catalyst that did not require such circulation would be favorable from the standpoint of minimum power consumption. Lasers designed for atmospheric penetration of their infrared radiation utilize CO2 formed from rare isotopes of oxygen and this application has the additional constraint that normal abundance oxygen isotopes in the catalyst must not exchange with rare isotopes in the gas mixture.
In vitro analysis of laser meniscectomy.
Vangsness, C T; Akl, Y; Nelson, S J; Liaw, L H; Smith, C F; Marshall, G J
1995-01-01
Partial meniscectomies were performed on 32 fresh human meniscal autopsy specimens. The following laser systems were tested: carbon dioxide (CO2), neodymium:yttrium aluminum garnet (Nd:YAG), potassium titanyl phosphate (KTP), holmium:YAG (Ho:YAG), and excimer. Meniscectomies with these lasers were compared with scalpel, mechanical, and electrocautery meniscectomies. Lasers were applied to specimens in and out of normal saline. Routine hematoxylin and eosin and sirius red sections were prepared for each specimen, and the depths of thermal changes were analyzed. Scanning electron microscopy was used to visualize the meniscectomy interface. Among these specimens, the scalpel and mechanical meniscectomies showed the least extension of cellular changes (range, 10-15 nm). The excimer laser caused the least tissue changes of the lasers tested. Tissue changes were less extensive with the pulsed CO2 laser than with the holmium:YAG, neodymium:YAG, and KTP lasers. Scanning electron microscopy showed that use of the scalpel meniscectomy resulted in the smoothest meniscectomy edge, followed by use of the excimer, CO2, holmium:YAG, neodymium:YAG, and KTP lasers. The most surface disruption occurred with electrocautery. Meniscectomies under saline required more energy and took longer in each case, with the holmium:YAG, neodymium:YAG, and CO2 laser cutting the best. Saline meniscectomies showed less thermal change. The CO2 and KTP lasers cut best in air.
Frequency tuning characteristics of a Q-switched Co:MgF2 laser
NASA Technical Reports Server (NTRS)
Lovold, S.; Moulton, P. F.; Killinger, D. K.; Menyuk, N.
1985-01-01
A tunable Q-switched Co:MgF2 laser has been developed for atmospheric remote sensing applications. Frequency tuning is provided by a quartz etalon and a specially designed three-element birefringent filter covering the whole gain bandwidth of the Co:MgF2 laser. The laser has good temporal and spectral characteristics, with an emission linewidth of approximately 3 GHz (0.1 per cm).
Carbon analysis for inspecting carbonation of concrete using a TEA CO2 laser-induced plasma.
Kagawa, Kiichiro; Idris, Nasrullah; Wada, Munehide; Kurniawan, Hendrik; Tsuyuki, Kenichiro; Miura, Satoru
2004-08-01
It has been demonstrated that a spectrochemical analysis of carbon using the laser plasma method can be successfully applied to inspect the carbonation of concrete by detecting carbon produced in aged concrete by a chemical reaction of Ca(OH)2 with CO2 gas in environmental air, turning into CaCO3, which induces degradation of the quality of building concrete. A comparative study has been made using a TEA CO2 laser (500-1000 mJ) and a Q-switched Nd-YAG laser (50-200 mJ) to search for the optimum conditions for carbon analysis, proving the advantage of the TEA CO2 laser for this purpose. Also, it was clarified that laser irradiation with suitable defocusing conditions is a crucial point for obtaining high sensitivity in the detection of carbon. Practical experiments on the inspection of carbonation were carried out using both a concrete sample that had been intentionally carbonated by exposure to high concentrations of CO2 gas and a naturally carbonated concrete sample. As a result, good coincidence was observed between the laser method and the ordinary method, which uses the chemical indicator phenolphthalein, implying that this laser technique is applicable as an in situ quantitative method of inspection for carbonation of concrete.
LASER BIOLOGY AND MEDICINE: Laser analysis of the 13C/12C isotope ratio in CO2 in exhaled air
NASA Astrophysics Data System (ADS)
Stepanov, E. V.
2002-11-01
Tunable diode lasers (TDLs) are applied to the diagnostics of gastroenterological diseases using respiratory tests and preparations enriched with the stable 13C isotope. This method of the analysis of the 13C/12C isotope ratio in CO2 in exhaled air is based on the selective measurement of the resonance absorption at the vibrational — rotational structure of 12CO2 and 13CO2. The CO2 transmission spectra in the region of 4.35 μm were measured with a PbEuSe double-heterostructure TDL. The accuracy of carbon isotope ratio measurements in CO2 of exhaled air performed with the TDL was ~0.5%. The data of clinical tests of the developed laser-based analyser are presented.
Faghihi, Gita; Nouraei, Saeid; Asilian, Ali; Keyvan, Shima; Abtahi-Naeini, Bahareh; Rakhshanpour, Mehrdad; Nilforoushzadeh, Mohammad Ali; Hosseini, Sayed Mohsen
2015-01-01
Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO2) laser resurfacing combined with punch elevation with fractional CO2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18–55) with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56). Their evaluation found that fractional CO2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO2 laser treatment alone, assessed 4 months after treatment (P = 0.02). Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO2 laser treatment was significant on both treatment sides (P < 0.05). Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring. PMID:26538695
Experimental Investigation for 100-Joule-class TEA CO2 Laser and Gas Interaction
NASA Astrophysics Data System (ADS)
Dou, Zhiguo; Yao, Honglin; Wang, Jun; Wen, Ming; Wang, Peng; Yang, Jan; Li, Chong
2006-05-01
Impulse coupling coefficient Cm is one of the most important performance parameters in laser propulsion. Cm is the impulse increment of lightcraft that per joule laser beam energy acts on. The TEA CO2 laser, whose single pulse energy is 100-Joule-class and wavelength is 10.6μm, is adopted by experimental research. In experimental environment cabin, the parabolic lightcraft is fixed on impact pendulum. Using Air, N2, He, CO2, N2-He and N2-CO2, different Cm is obtained. Experimental results indicate that Cm of the mixed gas is improved through changing gas component ratio.
NASA Astrophysics Data System (ADS)
Shen, J. D.; Yang, W. B.; Kumar, A.; Zhao, H. H.; Lai, Y. J.; Feng, L. S.; Xu, Q. Y.; Zhang, Y. Q.; Du, J.; Li, Q.
2018-04-01
Polycrystalline-BiFeO3(BFO)/Co bilayers were grown by pulsed laser deposition (PLD) and magnetron sputtering, with fast laser annealing under magnetic field. The enhanced exchange bias (EB) had been found in the BFO/Co bilayers (Appl. Surf. Sci. 367 (2016) 418). In order to reveal the origin of the enhanced EB in the samples, X-ray absorption Spectroscopy (XAS) of Fe 2p, Co 2p and O 1s were performed. The Co 2p XAS indicated the increase of Co oxidation state and the Fe 2p XAS of sample A and B under laser annealing processes showed that crystal field splitting energy decreased and led to the weakening of spin-orbit coupling with the increasing of the laser fluence. It was considered that the appearance of the oxidation state of Co and Fe2+ ions and the existence of the unidirectional anisotropy due to the laser fluence was responsible for the results and also for the enhanced EB.
NASA Astrophysics Data System (ADS)
Stepanov, Eugene V.; Zyrianov, Pavel V.; Miliaev, Valerii A.; Selivanov, Yurii G.; Chizhevskii, Eugene G.; Os'kina, Svetlana; Ivashkin, Vladimir T.; Nikitina, Elena I.
1999-07-01
An analyzer of 13CO2/12CO2 ratio in exhaled air based on lead-salt tunable diode lasers is presented. High accuracy of the carbon isotope ratio detection in exhaled carbon dioxide was achieved with help of very simple optical schematics. It was based on the use of MBE laser diodes operating in pulse mode and on recording the resonance CO2 absorption at 4.2 micrometers . Special fast acquisition electronics and software were applied for spectral data collection and processing. Developed laser system was tested in a clinical train aimed to assessment eradication efficiency in therapy of gastritis associated with Helicobacter pylori infection. Data on the 13C-urea breath test used for P.pylori detection and obtained with tunable diode lasers in the course of the trail was compared with the results of Mass-Spectroscopy analysis and histology observations. The analyzer can be used also for 13CO2/12CO2 ratio detection in exhalation to perform gastroenterology breath test based on using other compounds labeled with stable isotopes.
CO.sub.2 optically pumped distributed feedback diode laser
Rockwood, Stephen D.
1980-01-01
A diode laser optically pumped by a CO.sub.2 coherent source. Interference fringes generated by feeding the optical pumping beam against a second beam, periodically alter the reflectivity of the diode medium allowing frequency variation of the output signal by varying the impingent angle of the CO.sub.2 laser beams.
NASA Astrophysics Data System (ADS)
Schellhas, Helmut F.; Barnes, Alfonso E.
1982-12-01
Multipurpose surgical CO2 lasers marketed in the USA have been developed to be applicable to a variety of surgical procedures in many surgical fields. They are all suited for endoscopic surgical procedures and can be fitted to all standard surgical microscopes. They all can adjust the focal length of the laser beam to the different standard focal lengths of the surgical microscope which for instance in laryngoscopy is 400 mm and in colposcopy 300 mm. One laser instrument can even change the spot size in a given focal distance which is very advantageous for some microsurgical procedures (Merrimack Laboratories 820). All multipurpose surgical CO2 laser systems provide a multi-articulated surgical arm for free-hand surgery. The surgical arms are cumbersome to use but they are adapted to the surgeons needs with ingenuity. The practicality of the multi-articulated surgical arms depends mostly on the distance of the handpiece from the surgical console which now is also overbridged by the laser tube in most surgical laser system. The spot size of the beam is variable in most handpieces by interchangeable lenses which modify the focal distance of the beam and the power density. Another common feature in all systems is a coaxial He-Ne pilot light which provides a red spot which unfortunately becomes invisible in a bleeding surgical field. Most surgical laser systems have a spacial mode of TEM 00 which is essential for incisional surgery. The continuous mode of beam delivery is used for incisional surgery and also for most endoscopic procedures.
NASA Astrophysics Data System (ADS)
Obland, M. D.; Nehrir, A. R.; Liu, Z.; Chen, S.; Campbell, J. F.; Lin, B.; Kooi, S. A.; Fan, T. F.; Choi, Y.; Plant, J.; Yang, M. M.; Browell, E. V.; Harrison, F. W.; Meadows, B.; Dobler, J. T.; Zaccheo, T. S.
2015-12-01
This work describes advances in critical lidar technologies and techniques developed as part of the ASCENDS CarbonHawk Experiment Simulator (ACES) system for measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The ACES design demonstrates advancements in: (1) enhanced power-aperture product through the use and operation of multiple co-aligned laser transmitters and a multi-aperture telescope design; (2) high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration operation; and (4) advanced algorithms for cloud and aerosol discrimination. The ACES instrument, an Intensity-Modulated Continuous-Wave (IM-CW) lidar, was designed for high-altitude aircraft operations and can be directly applied to space instrumentation to meet the ASCENDS mission requirements. Specifically, the lidar simultaneously transmits three IM-CW laser beams from the high power EDFAs operating near 1571 nm. The outgoing laser beams are aligned to the field of view of three fiber-coupled 17.8-cm diameter telescopes, and the backscattered light collected by the same three telescopes is sent to the detector/TIA subsystem, which has a bandwidth of 4.9 MHz and operates service-free with a tactical Dewar and cryocooler. The electronic bandwidth is only slightly higher than 1 MHz, effectively limiting the noise level. Two key laser modulation approaches are being tested to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. This work provides an over view of these technologies, the modulation approaches, and results from recent test flights.
NASA Astrophysics Data System (ADS)
Obland, M. D.; Liu, Z.; Campbell, J. F.; Lin, B.; Kooi, S. A.; Carrion, W.; Hicks, J.; Fan, T. F.; Nehrir, A. R.; Browell, E. V.; Meadows, B.; Davis, K. J.
2016-12-01
This work describes advances in critical lidar technologies and techniques developed as part of the ASCENDS CarbonHawk Experiment Simulator (ACES) system for measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The ACES design demonstrates advancements in: (1) enhanced power-aperture product through the use and operation of multiple co-aligned laser transmitters and a multi-aperture telescope design; (2) high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration operation; and (4) advanced algorithms for cloud and aerosol discrimination. The ACES instrument, an Intensity-Modulated Continuous-Wave (IM-CW) lidar, was designed for high-altitude aircraft operations and can be directly applied to space instrumentation to meet the ASCENDS mission requirements. Specifically, the lidar simultaneously transmits three IM-CW laser beams from the high power EDFAs operating near 1571 nm. The outgoing laser beams are aligned to the field of view of three fiber-coupled 17.8-cm diameter telescopes, and the backscattered light collected by the same three telescopes is sent to the detector/TIA subsystem, which has a bandwidth of 4.9 MHz and operates service-free with a tactical Dewar and cryocooler. The electronic bandwidth is only slightly higher than 1 MHz, effectively limiting the noise level. Two key laser modulation approaches are being tested to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. This work provides an over view of these technologies, the modulation approaches, and results from recent test flights during the Atmospheric Carbon and Transport - America (ACT-America) Earth Venture Suborbital flight campaign.
Theoretical investigation of discharge parameters in magnetized radio frequency excited CO2 lasers
NASA Astrophysics Data System (ADS)
Tavassoli, H.; Sohbatzadeh, F.; Latifi, H.
2003-06-01
In the present paper the magnetic field effects on discharge parameters in rf excited CO2 lasers are calculated. A rf generated plasma imbedded in an external, constant, and homogeneous magnetic field is considered. The continuity equation is used to derive the electron density. Quasineutrality condition and ambipolar diffusion are used. Electron attachment coefficient is neglected. Local electric field, local electron density, and thickness of charge layers are derived as a function of distance from the electrodes and magnetic field. The thickness of charge layers in the presence of magnetic field is always smaller than one without the magnetic field. When the magnetic field increases, the electron density increases in all regions of discharge, and the electric field reduces in the charge layers but increases in the middle part of discharge.
NASA Technical Reports Server (NTRS)
Nelson, L. S.; Blander, M.; Keil, K.; Skaggs, S. R.
1972-01-01
Chondrule-like spherules were formed from individual freely falling subcooled droplets of alumina, enstatite, forsterite, enstatite-albite and forsterite-albite mixtures that had been melted with a focused continuous CO2 laser beam. Their textures (rimmed, excentro-radial, barred, glassy) are strikingly similar to those of many meteoritic chondrules. It is suggested that the phenomena associated with rapid crystallization from the supercooled melt are responsible for the various textures observed in the artificial spherules as well as in similar meteoritic chondrules. It is suggested that the textures observed would also result from rapid crystallization of relatively slowly cooling molten droplets that may have been produced in larger scale events, including condensation from a nebula of solar composition and solidification in an ambient medium of high temperature.
Advanced infrared laser modulator development
NASA Technical Reports Server (NTRS)
Cheo, P. K.; Wagner, R.; Gilden, M.
1984-01-01
A parametric study was conducted to develop an electrooptic waveguide modulator for generating continuous tunable sideband power from an infrared CO2 laser. Parameters included were the waveguide configurations, microstrip dimensions device impedance, and effective dielectric constants. An optimum infrared laser modulator was established and was fabricated. This modulator represents the state-of-the-art integrated optical device, which has a three-dimensional topology to accommodate three lambda/4 step transformers for microwave impedance matching at both the input and output terminals. A flat frequency response of the device over 20 HGz or = 3 dB) was achieved. Maximum single sideband to carrier power greater than 1.2% for 20 W microwave input power at optical carrier wavelength of 10.6 microns was obtained.
Zhou, Dechun; Bai, Xuemei; Zhou, Hang
2017-03-17
Ho 3+ /Tm 3+ co-doped 50TeO 2 -25GeO 2 -3WO 3 -5La 2 O 3 -3Nb 2 O 5 -5Li 2 O-9BaF 2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm 3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho 3+ is greatly influenced by the doping concentration ratio of Ho 3+ to Tm 3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10 -21 cm 2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm -1 , which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser.
NASA Astrophysics Data System (ADS)
Zhou, Dechun; Bai, Xuemei; Zhou, Hang
2017-03-01
Ho3+/Tm3+ co-doped 50TeO2-25GeO2-3WO3-5La2O3-3Nb2O5-5Li2O-9BaF2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho3+ is greatly influenced by the doping concentration ratio of Ho3+ to Tm3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10-21 cm2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm-1, which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser.
Zhou, Dechun; Bai, Xuemei; Zhou, Hang
2017-01-01
Ho3+/Tm3+ co-doped 50TeO2-25GeO2-3WO3-5La2O3-3Nb2O5-5Li2O-9BaF2 glass fiber is prepared with the rod-tube drawing method of 15 μm core diameter and 125 μm inner cladding diameter applied in the 2.0 μm-infrared laser. The 2.0 μm luminescence properties of the core glass are researched and the fluorescence intensity variation for different Tm3+ doping concentration is systematically analyzed. The results show that the 2.0 μm luminescence of Ho3+ is greatly influenced by the doping concentration ratio of Ho3+ to Tm3+ and that the maximum fluorescence intensity of the core glass can be obtained and its emission cross section can reach 0.933 × 10−21 cm2 when the sensitized proportion of holmium to thulium is 0.3 to 0.7 (mol%). Simultaneously, the maximum phonon energy of the core glass sample is 753 cm−1, which is significantly lower than that of silicate, gallate and germanate glass and the smaller matrix phonon energy can be conductive to the increase 2.0 μm-band emission intensity. The continuous laser with the maximum laser output power of 0.993 W and 2051 nm -wavelength of 31.9%-slope efficiency is output within the 0.5 m glass fiber and the experiment adopts 1560 nm erbium-doped fiber laser(EDFL) as the pump source and the self-built all-fiber laser. Therefore, the glass fiber has excellent laser characteristics and it is suitable for the 2.0 μm-band laser. PMID:28303946
Manolis, Evangelos N; Tsakris, Athanassios; Kaklamanos, Ioannis; Markogiannakis, Antonios; Siomos, Konstadinos
2006-03-01
Although beam-scanning carbon dioxide (CO2) lasers have provided a highly efficient tool for esthetic skin rejuvenation there has been no comprehensive animal studies looking into microbial skin changes following CO2 laser skin resurfacing. To evaluate the in vivo effects of CO2 laser skin resurfacing in an experimental rat model in comparison with mechanical abrasion on the skin microbial flora. Four separate cutaneous sections of the right dorsal surface of 10 Wistar rats were treated with a CO2 laser, operating at 18 W and delivering a radiant energy of 5.76 J/cm2, while mechanical abrasions of the skin were created on four sections of the left dorsal surface using a scalpel. Samples for culture and biopsies were obtained from the skin surfaces of the rats on day 1 of application of the CO2 laser or mechanical abrasion, as well as 10, 30, and 90 days after the procedure. The presence of four microorganisms (staphylococci, streptococci, diphtheroids, and yeasts) was evaluated as a microbe index for the skin flora, and colony counts were obtained using standard microbiological methods. Skin biopsy specimens, following CO2 laser treatment, initially showed epidermal and papillary dermal necrosis and later a re-epithelization of the epidermis as well as the generation of new collagen on the upper papillary dermis. The reduction in microbial counts on day 1 of the CO2 laser-inflicted wound was statistically significant for staphylococci and diphtheroids compared with the baseline counts (p=.004 and p<.001, respectively), and for staphylococci, diphtheroids, and yeasts compared with the scalpel-inflicted wound on the same day (p=0.029, p<.001, and p=.030, respectively). Skin resurfacing using CO2 lasers considerably reduces microbial counts of most microorganisms in comparison with either normal skin flora or a scalpel-inflicted wound. This might contribute to the positive clinical outcome of laser skin resurfacing.
In vitro evaluation of enamel demineralization after several overlapping CO2 laser applications.
Vieira, K A; Steiner-Oliveira, C; Soares, L E S; Rodrigues, L K A; Nobre-dos-Santos, M
2015-02-01
This study aimed to evaluate the effects of repeated CO2 laser applications on the inhibition of enamel demineralization. Sixty-five human dental enamel slabs were randomly assigned to the following groups (n = 13): control (C), one application of the CO2 laser (L1), two applications of the CO2 laser (L2), three applications of the CO2 laser (L3), and four applications of the CO2 laser (L4). Enamel slabs were irradiated by a 10.6-μm CO2 laser operating at 5 J/cm(2). The slabs were subjected to a pH-cycling regimen and then analyzed by FT-Raman spectroscopy, energy-dispersive X-ray fluorescence spectrometry (EDXRF), cross-sectional micro-hardness, and scanning electron microscopy (SEM). Statistical analysis was performed using ANOVA and Tukey tests (p < 0.05). FT-Raman spectroscopy showed a reduced carbonate content for L1, L3, and L4 groups when compared to C (p < 0.05). The EDXRF data showed no statistical differences between the control and irradiated groups for calcium and phosphorus components (p > 0.05). Cross-sectional micro-hardness data showed a statistically significant difference between the control and all irradiated groups (p < 0.05), but no difference was found among the irradiated groups (p > 0.05) up to 30-μm depth. A tendency of lower demineralization occurred in deeper depths for L3 and L4 groups. The SEM results showed that with repeated applications of the CO2 laser, a progressive melting and recrystallization of the enamel surface occurred. Repeated irradiations of dental enamel may enhance the inhibition of enamel demineralization.
Szymański, Marcin; Morshed, Kamal; Mills, Robert P
2007-01-01
The aim of the study was to assess the effect of CO(2) laser on stapes prostheses and measure the heat transmission to the vestibule in experiment model. CO(2) laser was applied on two types of prostheses with power settings (2 and 6W; 0.05 s). Transmission of heat to the 'vestibule' was measured using type K thermocouple and DC-80 data logger during application of the laser on prostheses using a training model of temporal bone. Application of the laser on stainless steel prosthesis did not have any effect on the structure of the prosthesis. The use of the laser on the fluoroplastic-wire piston caused melting and produced holes in the piston. Greater temperature rises occurred with stainless steel than with the fluoroplastic-wire piston. Application of CO(2) laser on stainless steel pistons with 6W can produce inner ear trauma. The use of the laser on fluoroplastic-wire piston is not likely to irritate the inner ear.
Pulsed laser facilities operating from UV to IR at the Gas Laser Lab of the Lebedev Institute
NASA Astrophysics Data System (ADS)
Ionin, Andrei; Kholin, Igor; Vasil'Ev, Boris; Zvorykin, Vladimir
2003-05-01
Pulsed laser facilities developed at the Gas Lasers Lab of the Lebedev Physics Institute and their applications for different laser-matter interactions are discussed. The lasers operating from UV to mid-IR spectral region are as follows: e-beam pumped KrF laser (λ= 0.248 μm) with output energy 100 J; e-beam sustained discharge CO2(10.6 μm) and fundamental band CO (5-6 μm) lasers with output energy up to ~1 kJ; overtone CO laser (2.5-4.2 μm) with output energy ~ 50 J and N2O laser (10.9 μm) with output energy of 100 J; optically pumped NH3 laser (11-14 μm). Special attention is paid to an e-beam sustained discharge Ar-Xe laser (1.73 μm ~ 100 J) as a potential candidate for a laser-propulsion facility. The high energy laser facilities are used for interaction of laser radiation with polymer materials, metals, graphite, rocks, etc.
NASA Astrophysics Data System (ADS)
Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli
2018-04-01
The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12CO2 and 13CO2 were mixed with N2 at various molar fraction ratios to obtain Raman quantification factors (F12CO2 and F13CO2), which provide a theoretical basis for calculating the δ13C value. And the corresponding values were 0.523 (0 < C12CO2/CN2 < 2) and 1.11998 (0 < C13CO2/CN2 < 1.5) respectively. It has shown that the representative Raman peak area can be used for the determination of δ13C values within the relative errors range of 0.076% to 1.154% in 13CO2/12CO2 binary mixtures when F12CO2/F13CO2 is 0.466972625. In addition, measurement of δ13C values by Micro-Laser Raman analysis were carried out on natural CO2 gas from Shengli Oil-field at room temperature under different pressures. The δ13C values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of δ13C values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (δ13C values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining δ13C values in natural CO2 gas reservoirs.
NASA Astrophysics Data System (ADS)
Kuo, Chun-Liang; Kao, Chia-Tze; Fang, Hsin-Yuan; Huang, Tsui-Hsien; Chen, Yi-Wen; Shie, Ming-You
2015-03-01
Macrophage cells are the important effector cells in the immune reaction which are indispensable for osteoclastogenesis; their heterogeneity and plasticity renders macrophages a primer target for immune system modulation. In recent years, there have been very few studies about the effects of macrophage cells on laser treatment-regulated osteoclastogenesis. In this study, RAW 264.7 macrophage cells were treated with RANKL to regulate osteoclastogenesis. We used a CO2 laser as a model biostimulation to investigate the role of osteoclastogenic. We also evaluated cell viability, cell death and cathepsin K expression. The CO2 laser inhibited a receptor activator of the NF-ĸB ligand (RANKL)-induced formation of osteoclasts during the osteoclast differentiation process. It was also found that irradiation for two times reduced RANKL-enhanced TRAP activity in a dose-dependent manner. Furthermore, CO2 laser-treatment diminished the expression and secretion of cathepsin K elevated by RANKL and was concurrent with the inhibition of TRAF6 induction and NF-ĸB activation. The current report demonstrates that CO2 laser abrogated RANKL-induced osteoclastogenesis by retarding osteoclast differentiation. The CO2 laser can modulate every cell through dose-dependent in vitro RANKL-mediated osteoclastogenesis, such as the proliferation and fusion of preosteoclasts and the maturation of osteoclasts. Therefore, the current results serve as an improved explanation of the cellular roles of macrophage cell populations in osteoclastogenesis as well as in alveolar bone remodeling by CO2 laser-treatment.
NASA Astrophysics Data System (ADS)
DeRowe, Ari; Ophir, Dov; Finkelstein, Y.; Katzir, Abraham
1993-07-01
CO2 laser myringotomy has previously been proven effective in patients with serous otitis media for short term aeration of the middle ear. However, the system based on a microscope and a coaxially aligned laser is cumbersome and expensive. Also, conventional optical fibers do not transmit CO2 laser energy ((lambda) equals 10.6 micrometers ). We have developed a silver halide optical fiber of diameter 0.9 mm and lengths of several meters, with high transmission at 10.6 micrometers . Using a hand held otoscope coupled to a fiberoptic delivery system CO2 laser myringotomies were performed first in guinea pigs and then in humans. In the animal model the feasibility of the procedure was proven. Different irradiation parameters were studied and a `dose dependent' relationship was found between the total energy used and the duration of a patent myringotomy. This system was used to perform CO2 laser myringotomies under local anesthesia in five patients with serous otitis media and conductive hearing loss. None of the patients complained of discomfort and no scarring was noted. All patients had subjective and audiometric documentation of hearing improvement. The average duration of a patent myringotomy was 21 days. In two patients the effusion recurred. CO2 laser myringotomy utilizing a hand held otoscope coupled to an optical fiber capable of transmitting CO2 laser energy may prove simple and effective in the treatment of serous otitis media.
Basir, Mahshid Mohammadi; Rezvani, Mohammad Bagher; Chiniforush, Nasim; Moradi, Zohreh
2016-01-01
Tooth restoration immediately after bleaching is challenging due to the potential problems in achieving adequate bond strength. The aim of this study was to evaluate the effect of surface treatment with ER:YAG, ND:YAG, CO2 lasers and 10% sodium ascorbate solution on immediate microtensile bond strength of composite resin to recently bleached enamel. Ninety sound molar teeth were randomly divided into three main groups (n:30) : NB (without bleaching), HB (bleached with 38% carbamide peroxide) and OB (bleached with Heydent bleaching gel assisted by diode laser). Each group was divided into five subgroups (n:6) : Si (without surface treatment), Er (Er:YAG laser), CO2 (CO2 laser), Nd (Nd:YAG laser) and As (Immersion in 10% sodium ascorbate solution). The bonding system was then applied and composite build-ups were constructed. The teeth were sectioned by low speed saw to obtain enamel- resin sticks and submitted to microtensile bond testing. Statistical analyses were done using two- way ANOVA, Tukey and Tamhane tests. µTBS of bleached teeth irradiated with ND:YAG laser was not significantly different from NB-Nd group. Microtensile bond strength of OB-Er group was higher than NB-Er and HB-Er groups. The mean µTBS of HB-CO2 group was higher than NB-CO2 group; the average µTBS of HB-As and OB-As groups was also higher than NB-As group. Use of Nd:YAG, CO2 lasers and 10% sodium ascorbate solution could improve the bond strength in home-bleached specimens. Application of ND:YAG laser on nonbleached specimens and Er:YAG laser on office-bleached specimens led to the highest µTBS in comparison to other surface treatments in each main group.
NASA Astrophysics Data System (ADS)
Baranov, V. Yu; Drokov, G. F.; Kuz'menko, V. A.; Mezhevov, V. S.; Pigul'skaya, V. V.
1986-05-01
The results of experiments on using hopcalite to stabilize the gas mixture composition in pulse-periodic and single-pulse CO2 lasers are reported. A study was made of the reasons for a fall in the activity of the catalyst with time under typical CO2 laser conditions and a catalyst regeneration regime was selected. The use of hopcalite ensured prolonged operation of a high-power pulse-periodic CO2 laser without replenishment of the gas mixture in a closed loop. Certain characteristic features concerning the use of hopcalite are described.
Paulos, Renato Siva; Seino, Priscila Yumi; Fukushima, Karen Akemi; Marques, Marcia Martins; de Almeida, Fernanda Campos Sousa; Ramalho, Karen Muller; de Freitas, Patricia Moreira; Brugnera, Aldo; Moreira, Maria Stella
2017-05-01
The aim of this study was to investigate Nd:YAG and CO 2 laser effects in the prevention of demineralization in deeper layers of enamel via successive acid challenge cycles. Lasers are promising in the prevention of enamel demineralization around the orthodontic brackets; however, there are very few studies that evaluate if the effects of treatment could be extended after successive acid challenge cycles due to permanent enamel structural alterations. Human enamel samples were divided into five groups (n = 12): G1-application of 1.23% acidulated fluoride phosphate gel (AFP, control); G2-Nd:YAG laser irradiation (0.6 W, 84.9 J/cm 2 , 10 Hz, 110 μs, contact mode); G3-Nd:YAG laser irradiation associated with AFP; G4-CO 2 laser irradiation (0.5 W, 28.6 J/cm 2 , 50 Hz, 5 μs, and 10 mm focal distance); and G5-CO 2 laser irradiation associated with AFP. The samples were submitted to successive acid challenge cycles. Quantitative light-induced fluorescence and scanning electron microscopy were used to assess enamel demineralization. The data were statistically compared (α = 5%). G1: 50.87 ± 4.57; G2: 47.72 ± 2.87; G3: 50.96 ± 4.01; G4: 28.21 ± 2.19; and G5: 30.13 ± 6.38. The CO 2 laser groups had significantly lower mineral losses than those observed in all other groups after successive acid challenge cycles. Only the CO 2 laser (10.6 μm) irradiation prevents enamel demineralization around the orthodontic brackets even after exposure to successive acid challenges. The CO 2 laser at 10.6 μm showed a deeper effect in enamel regarding caries prevention.
Au, Sonoa; Liolios, Ana M; Goldman, Mitchel P
2015-02-01
The picosecond Alexandrite laser has shown increased efficacy in tattoo removal in comparison to Q-switched lasers. However, bulla formation is a well-known and expected side effect of this novel treatment and causes patient discomfort. To analyze the incidence of bulla formation after tattoo treatment using the combination of the picosecond Alexandrite laser and fractionated CO2 ablation. This is a retrospective chart review to determine the incidence of bulla formation after laser tattoo removal in 95 patients who were treated with either with the picosecond Alexandrite laser alone or in combination with fractional CO2 ablation. Twenty-six patients (32%) treated with the picosecond laser alone experienced blistering, whereas none of the patients treated with the combination of the picosecond laser and fractionated CO2 ablation experienced blistering. The difference in incidence of bulla formation between the 2 groups was found to be statistically significant (p < .05). This study shows a significant decrease in bulla formation associated with tattoo treatment when fractionated CO2 ablation is added to the picosecond Alexandrite laser, which is consistent with observations from a previous case series. This is important because decreasing extensive blistering likely results in increased patient satisfaction and willingness to return for future treatments.
Kraeva, Ekaterina; Ho, Derek; Jagdeo, Jared
2016-11-01
Rhinophyma, a late complication of rosacea (phymatous subtype), is a chronic, progressive dermatological condition. The classic pre- sentation of rhinophyma is nodular, thickened skin over the distal nose, and is often accompanied by underlying erythema secondary to in ammation. Due to the unpleasant aesthetic and dis guring appearance, rhinophyma may be associated with a signi cant nega- tive psychosocial impact, resulting in decreased patient quality-of-life. Treatment of rhinophyma is challenging as topical and systemic pharmacotherapies have shown limited ef cacy. We present a case of a 39-year-old African-American male with long-standing, mild rhinophyma who was successfully treated with two sessions of fractionated carbon dioxide (CO2) laser. We also review the medical literature on fractionated CO2 laser treatment of rhinophyma. To the best of our knowledge, this is the rst report of successful treat- ment of rhinophyma using fractionated CO2 laser in an African-American man (Fitzpatrick VI). We believe that fractionated CO2 laser may be a safe and ef cacious treatment modality for rhinophyma in skin of color patients (Fitzpatrick IV-VI) and early intervention with fractionated CO2 laser to prevent rhinophyma worsening may yield better results than late intervention. J Drugs Dermatol. 2016;15(11):1465-1468..
Fiber optically guided CO2 laser myringotomy through an otoscope: animal experimentation
NASA Astrophysics Data System (ADS)
DeRowe, Ari; Ophir, Dov; Katzir, Abraham
1992-08-01
We have developed an otoscope which contains an optical fiber capable of transmitting CO2 laser energy. Such a hand-held unit may prove useful in the treatment of acute otitis media and otitis media with effusion. We used crystalline fibers (0.9 mm diameter) capable of transmitting CO2 laser energy. Four guinea pigs were anaesthetized. In one ear a laser myringotomy was performed using 7.5 watts for 0.1 seconds. The diameter of the myringotomy was 1.5 mm. In the other ear a similar conventional myringotomy was performed. After three weeks three laser and three conventional myringotomies were closed. On the average conventional myringotomies closed 50% sooner than laser myringotomies. Temporal bones from three guinea pigs were removed and sectioned according to accepted methods. No histological differences were found between ears. This experiment has proven the feasibility of using an otoscope for fiberoptically guided CO2 laser myringotomy.
NASA Technical Reports Server (NTRS)
Javan, A.
1979-01-01
A tunable multiatmospheric pulsed CO2 laser with emphasis on experimental features and supporting theoretical analyses important to differential absorption lidar and Doppler lidar measurement of pollutants and wind velocities is reported. The energy deposition and the means to produce the uniform high density plasma in the multiatmospheric medium, through UV preionization of an organic seed gas is discussed. Design features of the pulsed CO2 laser are presented. The radiative processes which are operative and prevent the laser from breaking into oscillations in a large number of modes over its broad amplification bandwidth are described. The mode competition for the transient pulsed laser oscillation in a standing wave and traveling wave ring laser configuration is discussed and contrasted with the approach to steady state oscillations. The latter findings are important to transient injection locking for production of a highly stable pulsed CO2 laser output.
Industrial 2-kW TEA CO2 laser for paint stripping of aircraft
NASA Astrophysics Data System (ADS)
Schweizer, Gerhard; Werner, L.
1995-03-01
Paint stripping of aircraft with pulsed laser radiation has several advantages compared to traditional methods of depainting: selective removal of individual layers possible, suitable for sensitive surfaces, workpiece ready for immediate repainting, and considerable reduction of contaminated waste. For paint stripping of large aircraft pulsed lasers with average power of at least 2 kW are required. Amongst the various types of pulsed lasers technical and economical considerations clearly favor TEA CO2 lasers for this application. The first commercially available TEA CO2 laser with an average power in excess of 2 kW, especially designed for depainting, has been developed by Urenco. The key data of this laser are: pulse energy up to 9 J, repetition rate up to 330 Hz, and beam quality: `flat top'.
Single-crystal Brillouin spectroscopy with CO{sub 2} laser heating and variable q
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jin S.; Bass, Jay D.; Zhu, Gaohua
2015-06-15
We describe a Brillouin spectroscopy system integrated with CO{sub 2} laser-heating and Raman spectroscopic capabilities. Temperature is determined by measurements of the grey-body thermal radiation emitted by the hot sample, with the system response calibrated relative to a standard tungsten ribbon lamp. High-pressure laser-heating Brillouin scattering measurements of acoustic velocities on liquid water and ice compressed in a diamond-anvil cell were performed at temperatures up to 2500 ± 150 K at high pressure. Single-crystal laser-heating Brillouin measurements were made on the (111) plane of San Carlos olivine at ∼13 GPa, 1300 ± 200 K. The pressure as measured by rubymore » fluorescence is shown to be within ±0.5 GPa of the pressure on the olivine sample during laser heating when KCl and KBr are used as pressure-transmitting media. In addition, the system is designed for continuously variable scattering angles from forward scattering (near 0° scattering angle) up to near back scattering (∼141°). This novel setup allows us to probe a wide range of wave vectors q for investigation of phonon dispersion on, for example, crystals with large unit cells (on the scale of hundreds of nm)« less
[The spectra of a laser-produced plasma source with CO2, O2 and CF4 liquid aerosol spray target].
Ni, Qi-Liang; Chen, Bo
2008-11-01
A laser-produced plasma (LPP) source with liquid aerosol spray target and nanosecond laser was developed, based on both soft X-ray radiation metrology and extreme ultraviolet projection lithography (EUVL). The LPP source is composed of a stainless steel solenoid valve whose temperature can be continuously controlled, a Nd : YAG laser with pulse width, working wavelength and pulse energy being 7 ns, 1.064 microm and 1J respectively, and a pulse generator which can synchronously control the valve and the laser. A standard General Valve Corporation series 99 stainless steel solenoid valve with copper gasket seals and a Kel-F poppet are used in order to minimize leakage and poppet deformation during high-pressure cryogenic operation. A close fitting copper cooling jacket surrounds the valve body. The jacket clamps a copper coolant carrying tube 3 mm in diameter, which is fed by an automatically pressurized liquid nitrogen-filled dewar. The valve temperature can be controlled between 77 and 473 K. For sufficiently high backing pressure and low temperature, the valve reservoir gas can undergo a gas-to-liquid phase transition. Upon valve pulsing, the liquid is ejected into a vacuum and breaks up into droplets, which is called liquid aerosol spray target. For the above-mentioned LPP source, firstly, by the use of Cowan program on the basis of non-relativistic quantum mechanics, the authors computed the radiative transition wavelengths and probabilities in soft X-ray region for O4+, O5+, O6+, O7+, F5+, F6+ and F7+ ions which were correspondingly produced from the interaction of the 10(11)-10(12) W x cm(-2) power laser with liquid O2, CO2 and CF4 aerosol spray targets. Secondly, the authors measured the spectra of liquid O2, CO2 and CF4 aerosol spray target LPP sources in the 6-20 nm band for the 8 x 10(11) W x cm(-2) laser irradiance. The measured results were compared with the Cowan calculated results ones, and the radiative transition wavelength and probability for the measured spectral lines were obtained.
CO(2) Laser Fascia to Dura Soldering for Pig Dural Defect Reconstruction.
Forer, Boaz; Vasileyev, Tamar; Gil, Ziv; Brosh, Tamar; Kariv, Naam; Katzir, Abraham; Fliss, Dan M
2007-02-01
The purposes of this study were to demonstrate that laser soldering is safe and effective for tissue bonding in dural reconstruction and to compare this new reconstruction technique to an established one. A temperature-controlled fiberoptic CO(2) laser system or fibrin glue were used for in vitro dural defect reconstruction in two groups of pigs. The CO(2) laser technique was also used for dural reconstruction in live pigs. The burst pressure of the reconstructed dura by the laser system was significantly higher than that of fibrin glue (mean pressure 258.5 +/- 117.3 cm H(2)O and 76.8 +/- 47.2 cm H(2)O, respectively). There were no postoperative complications and no signs of thermal damage to the dura, fascia, or underlying tissue on histological analysis following the in vivo CO(2) laser experiments. Temperature-controlled laser soldering is an effective technique for dural repair. It creates a strong tissue bonding with no thermal damage to the tissue. The burst pressure of the reconstructed dura done with laser soldering is significantly higher than that of fibrin glue.
Effect of the CO2 laser (9.6μm) on the dental pulp in humans
NASA Astrophysics Data System (ADS)
Wigdor, Harvey A.; Walsh, Joseph T., Jr.; Mostafi, Reza
2000-03-01
There has been great interest in the potential use of a laser to replace the dental handpiece (drill). Ideally a laser emitting radiation that is absorbed strongly by both the water and hydroxyapatite in teeth, would be a more efficient laser. Previous investigators showed that the 9.3 and 9.6 micron wavelength bands of the CO2 laser contain hydroxyapatite absorption peaks. For this study, human patients who were to have teeth removed for either orthodontic or periodontal reasons were used. A total of 16 teeth were irradiated. The number of teeth treated per patient varied from 1 - 4. The laser used was a prototype CO2 laser (ESC Medical Systems, Yokneam, Israel). The CO2 laser emits 50 mJ 60 microsecond-long pulses of 9.6 micrometer radiation in a beam focused to a 300 micrometer diameter (i/e2) spot. The pulps in both the laser and handpiece prepared holes appeared similar and had no apparent inflammation or vascular changes. It appears from this small sample of laser treated human teeth that this laser has an equal effect to the dental pulpal tissue when compared to the dental handpiece.
Kamalski, Digna M A; Verdaasdonk, Rudolf M; de Boorder, Tjeerd; Vincent, Robert; Trabelzini, Franco; Grolman, Wilko
2014-06-01
High-speed thermal imaging enables visualization of heating of the vestibule during laser-assisted stapedotomy, comparing KTP, CO2, and Thulium laser light. Perforation of the stapes footplate with laser bears the risk of heating of the inner ear fluids. The amount of heating depends on absorption of the laser light and subsequent tissue ablation. The ablation of the footplate is driven by strong water absorption for the CO2 and Thulium laser. For the KTP laser wavelength, ablation is driven by carbonization of the footplate and it might penetrate deep into the inner ear without absorption in water. The thermal effects were visualized in an inner ear model, using two new techniques: (1) high-speed Schlieren imaging shows relative dynamic changes of temperatures up to 2 ms resolution in the perilymph. (2) Thermo imaging provides absolute temperature measurements around the footplate up to 40 ms resolution. The high-speed Schlieren imaging showed minimal heating using the KTP laser. Both CO2 and Thulium laser showed heating below the footplate. Thulium laser wavelength generated heating up to 0.6 mm depth. This was confirmed with thermal imaging, showing a rise of temperature of 4.7 (±3.5) °C for KTP and 9.4 (±6.9) for Thulium in the area of 2 mm below the footplate. For stapedotomy, the Thulium and CO2 laser show more extended thermal effects compared to KTP. High-speed Schlieren imaging and thermal imaging are complimentary techniques to study lasers thermal effects in tissue.
Research on catalysts for long-life closed-cycle CO2 laser oaperation
NASA Technical Reports Server (NTRS)
Sidney, Barry D.; Schryer, David R.; Upchurch, Billy T.; Hess, Robert V.; Wood, George M.
1987-01-01
Long-life, closed-cycle operation of pulsed CO2 lasers requires catalytic CO-O2 recombination both to remove O2, which is formed by discharge-induced CO2 decomposition, and to regenerate CO2. Platinum metal on a tin-oxide substrate (Pt/SnO2) has been found to be an effective catalyst for such recombination in the desired temperature range of 25 to 100 C. This paper presents a description of ongoing research at NASA-Langley on Pt/SnO2 catalyzed CO-O2 recombination. Included are studies with rare-isotope gases since rare-isotope CO2 is desirable as a laser gas for enhanced atmospheric transmission. Results presented include: (1) the effects of various catalyst pretreatment techniques on catalyst efficiency; (2) development of a technique, verified in a 30-hour test, to prevent isotopic scrambling when C(O-18) and (O-18)2 are reacted in the presence of a common-isotope Pt/Sn(O-16)2 catalyst; and (3) development of a mathematical model of a laser discharge prior to catalyst introduction.
Characterization of diamond thin films and related materials
NASA Astrophysics Data System (ADS)
McKindra, Travis Kyle
Thin carbon films including sputtered deposited graphite and CO 2 laser-assisted combustion-flame deposited graphite and diamond thin films were characterized using optical and electron microscopy, X-ray diffraction and micro-Raman spectroscopy. Amorphous carbon thin films were deposited by DC magnetron sputtering using Ar/O2 gases. The film morphology changed with the oxygen content. The deposition rate decreased as the amount of oxygen increased due to oxygen reacting with the growing film. The use of oxygen in the working gas enhanced the crystalline nature of the films. Graphite was deposited on WC substrates by a CO2 laser-assisted O2/C2H2 combustion-flame method. Two distinct microstructural areas were observed; an inner core of dense material surrounded by an outer shell of lamellar-like material. The deposits were crystalline regardless of the laser power and deposition times of a few minutes. Diamond films were deposited by a CO2 laser-assisted O 2/C2H2/C2H4 combustion-flame method with the laser focused parallel to the substrate surface. The laser enhanced diamond growth was most pronounced when deposited with a 10.532 microm CO2 laser wavelength tuned to the CH2-wagging vibrational mode of the C2H4 molecule. Nucleation of diamond thin films deposited with and without using a CO 2 laser-assisted combustion-flame process was investigated. With no laser there was nucleation of a sub-layer of grains followed by irregular grain growth. An untuned laser wavelength yielded nucleation of a sub-layer then columnar grain growth. The 10.532 microm tuned laser wavelength caused growth of columnar grains.
Optical radiation hazards of laser welding processes. Part II: CO2 laser.
Rockwell, R J; Moss, C E
1989-08-01
There has been an extensive growth within the last five years in the use of high-powered lasers in various metalworking processes. The two types of lasers used most frequently for laser welding/cutting processes are the Neodymium-yttrium-aluminum-garnet (Nd:YAG) and the carbon dioxide (CO2) systems. When such lasers are operated in an open beam configuration, they are designated as a Class IV laser system. Class IV lasers are high-powered lasers that may present an eye and skin hazard under most common exposure conditions, either directly or when the beam has been diffusely scattered. Significant control measures are required for unenclosed (open beam), Class IV laser systems since workers may be exposed to scattered or reflected beams during the operation, maintenance, and service of these lasers. In addition to ocular and/or skin exposure hazards, such lasers also may present a multitude of nonlaser beam occupational concerns. Radiant energy measurements are reported for both the scattered laser radiation and the plasma-related plume radiations released during typical high-powered CO2 laser-target interactions. In addition, the application of the nominal hazard zone (NHZ) and other control measures also are discussed with special emphasis on Class IV industrial CO2 laser systems.
Laser spectrometer for CO2 clumped isotope analysis
NASA Astrophysics Data System (ADS)
Prokhorov, Ivan; Kluge, Tobias; Janssen, Christof
2017-04-01
Carbon dioxide clumped isotope thermometry has proven to be a reliable method for biogeochemical and atmospheric research. We present a new laser spectroscopic instrument for doubly-substituted isotopologues analysis. In contrast to a conventional isotope ratio mass spectrometry (IRMS), tunable laser direct absorption spectroscopy (TLDAS) has the advantage of isotopologue-specific determination free of isobaric interferences. Tunable infrared laser based spectrometer for clumped isotope analysis is being developed in collaboration between Heidelberg University, Germany, and LERMA-IPSL, CNRS, France. The instrument employs two continuous intraband cascade lasers (ICL) tuned at 4439 and 4329 nm. The spectral windows covered by the lasers contain absorption lines of the six most abundant CO2 isotopologues, including the two doubly substituted species 16O13C18O and 16O13C17O, and all singly substituted isotopologues with 13C, 18O and 17O. A Herriott-type multi-pass cell provides two different absorption pathlengths to compensate the abundance difference between singly- and doubly-substituted isotopologues. We have reached the sub-permill precision required for clumped isotope measurements within the integration time of several seconds. The test version of the instrument demonstrates a performance comparable to state of the art IRMS. We highlight the following features of the instrument that are strong advantages compared to conventional mass spectrometry: measurement cycle in the minute range, simplified sample preparation routine, table-top layout with a potential for in-situ applications.
Observations of the Seasonal Polar Icecaps of Mars at 1064 nm
NASA Technical Reports Server (NTRS)
Zuber, Maria T.; Smith, David E.
2003-01-01
The Mars Orbiter Laser Altimeter (MOLA) is routinely making radiometric observations of Mars at a wavelength of 1064 nm. Although the altimeter function is no longer operational, the MOLA detector continues to measure the reflectivity of the surface. Observations have been obtained almost continuously since the beginning of the Mars Global Surveyor (MGS) mapping mission in February 1999, and are providing measurements relevant to understanding the seasonal cycling of CO2 surface frost.
Salvatore, Stefano; Leone Roberti Maggiore, Umberto; Athanasiou, Stavros; Origoni, Massimo; Candiani, Massimo; Calligaro, Alberto; Zerbinati, Nicola
2015-08-01
Microablative fractional CO2 laser has been proven to determine tissue remodeling with neoformation of collagen and elastic fibers on atrophic skin. The aim of our study is to evaluate the effects of microablative fractional CO2 laser on postmenopausal women with vulvovaginal atrophy using an ex vivo model. This is a prospective ex vivo cohort trial. Consecutive postmenopausal women with vulvovaginal atrophy managed with pelvic organ prolapse surgical operation were enrolled. After fascial plication, the redundant vaginal edge on one side was treated with CO2 laser (SmartXide2; DEKA Laser, Florence, Italy). Five different CO2 laser setup protocols were tested. The contralateral part of the vaginal wall was always used as control. Excessive vagina was trimmed and sent for histological evaluation to compare treated and nontreated tissues. Microscopic and ultrastructural aspects of the collagenic and elastic components of the matrix were studied, and a specific image analysis with computerized morphometry was performed. We also considered the fine cytological aspects of connective tissue proper cells, particularly fibroblasts. During the study period, five women were enrolled, and 10 vaginal specimens were finally retrieved. Four different settings of CO2 laser were compared. Protocols were tested twice each to confirm histological findings. Treatment protocols were compared according to histological findings, particularly in maximal depth and connective changes achieved. All procedures were uneventful for participants. This study shows that microablative fractional CO2 laser can produce a remodeling of vaginal connective tissue without causing damage to surrounding tissue.
NASA Astrophysics Data System (ADS)
Hsu, T.-T.; Kao, C.-T.; Chen, Y.-W.; Huang, T.-H.; Yang, J.-J.; Shie, M.-Y.
2015-05-01
Calcium silicate-based material (CS) has been successfully used in dental clinical applications. Some researches show that the antibacterial effects of CO2 laser irradiation are highly efficient when bacteria are embedded in biofilm, due to a photo-thermal mechanism. The purpose of this study was to confirm the effects of CO2 laser irradiation on CS, with regard to both material characterization and human periodontal ligament cell (hPDLs) viability. CS was irradiated with a dental CO2 laser using directly mounted fiber optics in wound healing mode with a spot area of 0.25 cm2, and then stored in an incubator at 100% relative humidity and 37 °C for 1 d to set. The hPDLs cultured on CS were analyzed, along with their proliferation and odontogenic differentiation behaviors. The results indicate that the CO2 laser irradiation increased the amount of Ca and Si ions released from the CS, and regulated cell behavior. CO2 laser-irradiated CS promoted cementogenic differentiation of hPDLs, with the increased formation of mineralized nodules on the substrate’s surface. It also up-regulated the protein expression of multiple markers of cementogenic and the expression of cementum attachment protein. The current study provides new and important data about the effects of CO2 laser irradiation on CS. Taking cell functions into account, the Si concentration released from CS with laser irradiated may be lower than a critical value, and this information could lead to the development of new regenerative therapies for dentin and periodontal tissue.
Rastogi, Pavitra Kumar; Lal, Nand; Garg, Nimit; Anand, Vishal; Singhal, Rameshwari
2012-01-01
Localised gingival recessions continue to represent an important aesthetic condition requiring treatment in periodontics. Various techniques have been tried to treat exposed root surfaces to improve aesthetics with high percentage of success and minimal discomfort. Root biomodification is done to improve the predictability of these procedures. This clinical report describes periodontal plastic procedure involving subepithelial connective tissue graft with lateral repositioned flap technique and root biomodification with CO2 laser for the management of gingival recession. PMID:22778454
A Broadband Infrared Laser Source (2.5-17 μm) for Plasma Diagnostics
NASA Astrophysics Data System (ADS)
Ionin, A. A.; Kinyaevskii, I. O.; Klimachev, Yu. M.; Kozlov, A. Yu.; Kotkov, A. A.
2017-12-01
This paper presents the results of studies aimed at the creation of a hybrid laser system which is composed of a gas lasers and a nonlinear crystal and appreciably broadens and enriches the radiation spectrum of these lasers. A highly efficient conversion (37%) is attained when generating the second harmonic in a ZnGeP2 crystal owing to an increase in the peak power of CO laser radiation in the mode locking regime. The two-cascade conversion (generation of both sum and difference frequencies) of radiation of a broadband CO laser in the single sample of such nonlinear crystals as ZnGeP2 and AgGaSe2 is demonstrated. In this case, the radiation spectrum is broadened by nearly a factor of two, and the number of detected spectral lines grows by a factor of four. The use of a comparatively simple laser system of gas-discharge CO and CO2 lasers to conversion in AgGaSe2 results in laser radiation tunable over a set of narrow spectral lines within a range from 2.5 to 16.6 μm (more than two and a half octaves).
Effects of Nd:YAG and CO2 lasers on cerebral microvasculature. Study in normal rabbit brain.
Kuroiwa, T; Tsuyumu, M; Takei, H; Inaba, Y
1986-01-01
The effect of Nd:YAG and CO2 laser beams on cerebral microvasculature was examined in experimental animals. Soft x-ray microangiography and histological examination of the brain after Nd:YAG laser exposure revealed broad avascular or oligovascular zones in the irradiated and the surrounding edematous tissue, in which the surviving vessels were narrowed and tapered without significant leakage of blood. After CO2 laser exposure, a wedge-shaped tissue defect surrounded by layers of charring, coagulation, and edema was observed. The main finding in the surrounding coagulation and edematous layers was dilatation of the vessels. Hemorrhage was sometimes observed, mainly in the edematous layer. These findings seem to explain the effective hemostatic capability of the Nd:YAG laser and the occasional hemorrhage following CO2 laser exposure, especially at high energy output.
[Experimental investigations of CO2 laser application in middle ear ossicles].
Dazert, S; Russ, D; Mlynski, R; Brors, D; Greiner, A; Aletsee, C; Helms, J
2003-07-01
During the last few years, several laser systems have been applied for procedures in middle ear surgery. In this study, we determined the technical parameters for the dissection of the middle ear ossicles with the CO(2) laser and analyzed the histological findings. The malleus necks of 16 human temporal bones were dissected under standardized conditions using a CO(2) laser with a power output between 35 and 55 kW/cm(2). The specimens were fixed and histological probes of 50- micro m thickness were prepared. The laser outputs led to crater diameters from 0.14 to 0.55 mm. As an analogy between laser energy and thermal tissue destruction, three zones of thermal damage were differentiated: a cinder zone, a carbonization zone, and a zone of dehydration. The metrical dimensions of these zones did not show any correlation to the applied laser energy. The data of this study show that commercially available CO(2) lasers are sufficient for a safe and effective partial resection of middle ear ossicles using a power output of 35 kW/cm(2).
NASA Technical Reports Server (NTRS)
Abshire, James; Riris, Haris; Allan, Graham; Weaver, Clark; Mao, Jianping; Sun, Xiaoli; Hasselbrack, William
2010-01-01
We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's planned ASCENDS space mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1570 nm band, O2 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are rapidly and precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Time gating is used to isolate the laser echo signals from the surface, and to reject laser photons scattered in the atmosphere. The time of flight of the laser pulses are also used to estimate the height of the scattering surface and to identify cases of mixed cloud and ground scattering. We have developed an airborne lidar to demonstrate the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar steps the pulsed laser's wavelength across the selected CO2 line with 20 steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a photomultiplier and is recorded by a photon counting system. We made initial airborne measurements on flights during fall 2008. Laser backscatter and absorption measurements were made over a variety of land and water surfaces and through thin clouds. The atmospheric CO2 column measurements using the 1572.33 nm CO2 lines. Two flights were made above the US Department of Energy's (DOE) SGP ARM site at altitudes from 3-8 km. These flights were coordinated with DOE investigators who flew an in-situ CO2 sensor on a Cessna aircraft under the path. The increasing CO2 line absorptions with altitudes were evident and comparison with in-situ measurements showed agreements to 6 ppm. In spring 2009 we improved the aircraft's nadir window and during July and August we made 9 additional 2 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over a variety of surface types in Nebraska, Illinois, the SGP ARM site, and near and over the Chesapeake Bay in North Carolina and eastern Virginia. Strong laser signals and clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The flights over the ARM site were underflown with in-situ measurements made from the DOE Cessna. Analysis shows that the average signal levels follow predicted values, the altimetry measurements had an uncertainty of about 4 m, and that the average optical line depths follow the number density calculated from in-situ sensor readings. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, a LaRC in-situ CO2 sensor, and the Oklahoma flights also included a JPL CO2 lidar on a Twin Otter aircraft. More details of the flights, measurements, analysis and scaling to space will be described in the presentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avtonomov, V.P.; Alexandrescu, R.; Dumitras, D.
1979-02-01
Results are presented of measurements of the Stark modulation index and absorption coefficient of CO/sub 2/ laser radiation due to the P (24) line by 1-1 difluorethane (C/sub 2/H/sub 4/F/sub 2/). The possibility of stabilizing the CO/sub 2/ laser frequency using a Stark cell is demonstrated and the laser frequency tuning efficiency within the P (24) line of the 00/sup 0/1--10/sup 0/0 transition is determined.
Perkins, Bradford G; Häber, Thomas; Nesbitt, David J
2005-09-01
An apparatus for detailed study of quantum state-resolved inelastic energy transfer dynamics at the gas-liquid interface is described. The approach relies on supersonic jet-cooled molecular beams impinging on a continuously renewable liquid surface in a vacuum and exploits sub-Doppler high-resolution laser absorption methods to probe rotational, vibrational, and translational distributions in the scattered flux. First results are presented for skimmed beams of jet-cooled CO(2) (T(beam) approximately 15 K) colliding at normal incidence with a liquid perfluoropolyether (PFPE) surface at E(inc) = 10.6(8) kcal/mol. The experiment uses a tunable Pb-salt diode laser for direct absorption on the CO(2) nu(3) asymmetric stretch. Measured rotational distributions in both 00(0)0 and 01(1)0 vibrational manifolds indicate CO(2) inelastically scatters from the liquid surface into a clearly non-Boltzmann distribution, revealing nonequilibrium dynamics with average rotational energies in excess of the liquid (T(s) = 300 K). Furthermore, high-resolution analysis of the absorption profiles reveals that Doppler widths correspond to temperatures significantly warmer than T(s) and increase systematically with the J rotational state. These rotational and translational distributions are consistent with two distinct gas-liquid collision pathways: (i) a T approximately 300 K component due to trapping-desorption (TD) and (ii) a much hotter distribution (T approximately 750 K) due to "prompt" impulsive scattering (IS) from the gas-liquid interface. By way of contrast, vibrational populations in the CO(2) bending mode are inefficiently excited by scattering from the liquid, presumably reflecting much slower T-V collisional energy transfer rates.
NASA Astrophysics Data System (ADS)
Abdul Ghani, B.
2005-09-01
"TEA CO 2 Laser Simulator" has been designed to simulate the dynamic emission processes of the TEA CO 2 laser based on the six-temperature model. The program predicts the behavior of the laser output pulse (power, energy, pulse duration, delay time, FWHM, etc.) depending on the physical and geometrical input parameters (pressure ratio of gas mixture, reflecting area of the output mirror, media length, losses, filling and decay factors, etc.). Program summaryTitle of program: TEA_CO2 Catalogue identifier: ADVW Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADVW Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Computer: P.IV DELL PC Setup: Atomic Energy Commission of Syria, Scientific Services Department, Mathematics and Informatics Division Operating system: MS-Windows 9x, 2000, XP Programming language: Delphi 6.0 No. of lines in distributed program, including test data, etc.: 47 315 No. of bytes in distributed program, including test data, etc.:7 681 109 Distribution format:tar.gz Classification: 15 Laser Physics Nature of the physical problem: "TEA CO 2 Laser Simulator" is a program that predicts the behavior of the laser output pulse by studying the effect of the physical and geometrical input parameters on the characteristics of the output laser pulse. The laser active medium consists of a CO 2-N 2-He gas mixture. Method of solution: Six-temperature model, for the dynamics emission of TEA CO 2 laser, has been adapted in order to predict the parameters of laser output pulses. A simulation of the laser electrical pumping was carried out using two approaches; empirical function equation (8) and differential equation (9). Typical running time: The program's running time mainly depends on both integration interval and step; for a 4 μs period of time and 0.001 μs integration step (defaults values used in the program), the running time will be about 4 seconds. Restrictions on the complexity: Using a very small integration step might leads to stop the program run due to the huge number of calculating points and to a small paging file size of the MS-Windows virtual memory. In such case, it is recommended to enlarge the paging file size to the appropriate size, or to use a bigger value of integration step.
Kesler, G; Koren, R; Kesler, A; Hay, N; Gal, R
1998-10-01
Until now, no suitable delivery fiber has existed for CO2 laser endodontic radiation in the apical region, where it is most difficult to eliminate the pulp tissue using conventional methods. To overcome this problem, we have designed a microprobe that reaches closer to the apex, distributing the energy density to a smaller area of the root canal and thus favorably increasing the thermal effects. A CO2 laser microprobe coupled onto a special hand piece was attached to the delivery fiber of a Sharplan 15-F CO2 laser. The study was conducted on 30 vital maxillary or mandibulary, central, lateral, or premolar teeth destined for extraction due to periodontal problems. Twenty were experimentally treated with pulsed CO2 laser delivered by this newly developed fiber after conventional root canal preparation. Temperature measured at three points on the root surface during laser treatment did not exceed 38 degrees C. Ten teeth represented the control group, in which only root canal preparation was performed in the conventional method. Histological examination of the laser-treated teeth showed coagulation necrosis and vacuolization of the remaining pulp tissue in the root canal periphery. Primary and secondary dentin appeared normal in all cases treated with 15-F CO2 laser. Gram stain and bacteriologic examination revealed complete sterilization. These results demonstrate the unique capabilities of this special microprobe in sterilization of the root canal, with no thermal damage to the surrounding tissue. The combination of classical root canal preparation with CO2 laser irradiation using this special microprobe before closing the canal can drastically change the quality of root canal fillings.
Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli
2018-04-15
The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12 CO 2 and 13 CO 2 were mixed with N 2 at various molar fraction ratios to obtain Raman quantification factors (F 12CO2 and F 13CO2 ), which provide a theoretical basis for calculating the δ 13 C value. And the corresponding values were 0.523 (0
Lepri, Taísa Penazzo; Scatolin, Renata Siqueira; Colucci, Vivian; De Alexandria, Adílis Kalina; Maia, Lucianne Cople; Turssi, Cecília Pedroso; Corona, Silmara Aparecida Milori
2014-08-01
The present study aimed to evaluate in situ the effect of CO2 laser irradiation to control the progression of enamel erosive lesions. Fifty-six slabs of bovine incisors enamel (5 × 3 × 2.5 mm(3) ) were divided in four distinct areas: (1) sound (reference area), (2) initial erosion, (3) treatment (irradiated or nonirradiated with CO2 laser), (4) final erosion (after in situ phase). The initial erosive challenge was performed with 1% citric acid (pH = 2.3), for 5 min, 2×/day, for 2 days. The slabs were divided in two groups according to surface treatment: irradiated with CO2 laser (λ = 10.6 µm; 0.5 W) and nonirradiate. After a 2-day lead-in period, 14 volunteers wore an intraoral palatal appliance containing two slabs (irradiated and nonirradiated), in two intraoral phases of 5 days each. Following a cross-over design during the first intraoral phase, half of the volunteers immersed the appliance in 100 mL of citric acid for 5 min, 3×/day, while other half of the volunteers used deionized water (control). The volunteers were crossed over in the second phase. Enamel wear was determined by an optical 3D profilometer. Three-way ANOVA for repeated measures revealed that there was no significant interaction between erosive challenge and CO2 laser irradiation (P = 0.419). Erosive challenge significantly increased enamel wear (P = 0.001), regardless whether or not CO2 laser irradiation was performed. There was no difference in enamel wear between specimens CO2 -laser irradiated and non-irradiated (P = 0.513). Under intraoral conditions, CO2 laser irradiation did not control the progression of erosive lesions in enamel caused by citric acid. © 2014 Wiley Periodicals, Inc.
Fractional CO2 Laser Resurfacing Complications
Ramsdell, William M.
2012-01-01
Fractionated CO2 laser technology has allowed physicians to resurface patients with a lower rate of complications than nonfractionated ablative laser treatment. Unfortunately, adverse effects can still occur even with the best technology and physician care. Complication prevention, detection, and treatment are an important part of a physician's ability to provide the best result when treating a patient with fractionated CO2 resurfacing. PMID:23904822
Makboul, Mohamed; Makboul, Rania; Abdelhafez, Assem Hk; Hassan, Safaa Said; Youssif, Sherif M
2014-09-01
Hypertrophic scar is a form of abnormal wound healing process in which tissue repair regulating mechanism is disrupted. Transforming growth factor β1 has a particular importance in the fibrotic scarring response. Treatment of hypertrophic scar included many chemical, physical, and surgical options. Fractional CO2 laser devices have gained acceptance as a way for managing hypertrophic scar. Aims of this study are: (a) to determine the clinical and histopathological effects of fractional CO2 laser on hypertrophic scar, (b) to evaluate the expression pattern of transforming growth factor-β1 (TGF-β1) as an important fibrogenic factor before and 6 months after fractional CO2 laser treatment. Forty patients of hypertrophic scar were selected, each patient was treated by four sessions with 1 month apart with fractional CO2 laser. Vancouver Scar Scale (VSS) was used to assess the patients before and after laser treatment. Skin biopsy was taken from eight cases before and 3 months after four fractional CO2 laser sessions and four normal skin control biopsies. All were assessed by hematoxylin-eosin (H&E), Masson's trichrome, Van Gieson and immunohistochemical (IHC) staining with TGF-β1. The epidermal thickness was assessed before and after treatment by image analyzing system software. There was statistically significant difference in VSS before and after fractional CO2 laser (P > 0.001). The epidermal thickness showed significant increase after laser treatment (P > 0.001), and there was also thinning in stratum corneum and replacement of the irregular collagen bands with organized new collagen fibrils as demonstrated by H&E and the other special stains. The study also showed significant decrease in TGF-β1 expression after laser therapy (P = 0.008). Fractional CO2 laser could be considered as a good way for hypertrophic scar management. It normalizes dermal collagen as imaged by histopathological picture and the change in TGF-β1 expression. © 2014 Wiley Periodicals, Inc.
Lee, Sang Jun; Suh, Dong Hye; Chang, Ka Yeon; Kim, Hyun Joo; Kim, Tae In; Jeong, Ki-Heon; Shin, Min Kyung; Song, Kye Yong
2016-11-01
Various modalities have been used to treat acne scars. CO 2 fractional laser is an effective and commonly used treatment. CO 2 gas injection into the dermis by needle with high pressure can cause fibrotic collagen breakage, producing the effects of subcision. CO 2 also stimulates collagen synthesis by increasing neovascularization and releasing oxygen. This study evaluated the efficacy and the safety of the combined treatment with CO 2 gas subcision and CO 2 fractional laser for acne scars. Fourteen patients with acne scars were treated with three sessions of CO 2 gas subcision at 2-week intervals and two sessions of fractional laser at 4-week interval. The clinical improvement was assessed using a 4-point scale. For histologic analysis, punch biopsy was performed before and after treatment in 10 patients. All patients experienced clinical improvements. Excellent, marked, moderate, and mild response was achieved in 1 (7%), 8 (57%), 4 (29%), and 1 patient (7%), respectively. Histologic evaluation of the biopsy specimens showed increased dermal collagen with dermal thickening and elastic fiber straightening in the reticular dermis after the treatment. The combination therapy with CO 2 gas subcision and fractional laser was satisfactory and safe for treating acne scars. Abbreviation and acronym: CO 2 : Carbon dioxide GAS: Global assessment scale H&E: hematoxylin and eosin; SD: standard deviation.
Fractional CO2 lasers contribute to the treatment of stable non-segmental vitiligo.
Yuan, Jinping; Chen, Hongqiang; Yan, Ru; Cui, Shaoshan; Li, Yuan-Hong; Wu, Yan; Gao, Xing-Hua; Chen, Hong-Duo
2016-12-01
Stable non-segmental vitiligo is often resistant to conventional therapies. The purpose of this study was to investigate the effect of three types of fractional lasers in the treatment of stable non-segmental vitiligo. Twenty patients were enrolled in the study. The vitiligo lesions of each patient were divided into four treatment parts, and all parts were treated with narrowband ultraviolet-B (NB-UVB). Three of the four parts were respectively treated with three types of fractional lasers (two ablative 10,600-nm CO 2 lasers and one non-ablative 1,565-nm laser), followed by topical betamethasone solution application. The treatment period lasted six months. Efficacy and satisfaction were respectively assessed by dermatologists and patients. The ablative CO 2 lasers, in combination with topical betamethasone solution and NB-UVB, achieved marked to excellent improvement on white patches assessed by dermatologists. Patients showed high satisfaction scores for the treatments. The non-ablative 1,565-nm fractional laser did not provide any further benefit in the treatment of vitiligo. No severe adverse events developed for any of the treatments. The treatment protocol with ablative CO 2 lasers, in combination with topical betamethasone solution and NB-UVB, was suitable for stable non-segmental vitiligo. For vitiligo, the ablative fractional CO 2 laser is more effective than the non-ablative fractional laser.
NASA Astrophysics Data System (ADS)
Osuna, J. L.; Bora, M.; Bond, T.
2015-12-01
One method to constrain photosynthesis and respiration independently at the ecosystem scale is to measure the fluxes of CO2 isotopologues. Instrumentation is currently available to makes these measurements but they are generally costly, large, bench-top instruments. Here, we present progress toward developing a laser-based sensor that can be deployed directly to a canopy to passively measure CO2 isotopologue fluxes. In this study, we perform initial proof-of-concept and sensor characterization tests in the laboratory and in the field to demonstrate performance of the Lawrence Livermore National Laboratory (LLNL) tunable diode laser flux sensor. The results shown herein demonstrate measurement of bulk CO2 as a first step toward achieving flux measurements of CO2 isotopologues. The sensor uses a Vertical Cavity Surface Emitting Laser (VCSEL) in the 2012 nm range. The laser is mounted in a multi-pass White Cell. In order to amplify the absorption signal of CO2 in this range we employ wave modulation spectroscopy, introducing an alternating current (AC) bias component where f is the frequency of modulation on the laser drive current in addition to the direct current (DC) emission scanning component. We observed a strong linear relationship (r2 = 0.998 and r2 = 0.978 at all and low CO2 concentrations, respectively) between the 2f signal and the CO2 concentration in the cell across the range of CO2 concentrations relevant for flux measurements. We use this calibration to interpret CO2 concentration of a gas flowing through the White cell in the laboratory and deployed over a grassy field. We will discuss sensor performance in the lab and in situ as well as address steps toward achieving canopy-deployed, passive measurements of CO2 isotopologue fluxes. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-675788
Cai, Tingdong; Gao, Guangzhen; Liu, Ying
2012-10-01
A multiplexed diode-laser sensor system based on second harmonic detection of wavelength modulation spectroscopy (WMS) is developed for application at elevated temperatures with two near-infrared diode lasers multiplexed using a frequency-division multiplexing scheme. One laser is tuned over a H(2)O line pair near 7079.176 and 7079.855 cm(-1), and another laser is tuned over a pair of CO(2) and CO lines near 6361.250 and 6361.344 cm(-1). Temperature and concentrations of H(2)O, CO(2), and CO could be measured simultaneously by this system. In order to remove the need for calibration and correct for transmission variation due to beam steering, mechanical misalignments, soot, and windows fouling, the WMS-1f normalized 2f method is used. Demonstration experiments are conducted in a heated static cell. The precision of temperature and the concentrations for H(2)O, CO(2), and CO are found to be 1.57%, 3.87%, 3.01%, and 3.58%, respectively. These results illustrate the potential of this sensor for applications at high temperatures.
Multiparameter bifurcations and mixed-mode oscillations in Q-switched CO2 lasers.
Doedel, Eusebius J; Pando L, Carlos L
2014-05-01
We study the origin of mixed-mode oscillations and related bifurcations in a fully molecular laser model that describes CO2 monomode lasers with a slow saturable absorber. Our study indicates that the presence of isolas of periodic mixed-mode oscillations, as the pump parameter and the cavity-frequency detuning change, is inherent to Q-switched CO2 monomode lasers. We compare this model, known as the dual four-level model, to the more conventional 3:2 model and to a CO2 laser model for fast saturable absorbers. In these models, we find similarities as well as qualitative differences, such as the different nature of the homoclinic tangency to a relevant unstable periodic orbit, where the Gavrilov-Shilnikov theory and its extensions may hold. We also show that there are isolas of periodic mixed-mode oscillations in a model for CO2 lasers with modulated losses, as the pump parameter varies. The coarse-grained bifurcation diagrams of the periodic mixed-mode oscillations in these models suggest that these oscillations belong to similar classes.
CO2 lasers in the management of potentially malignant and malignant oral disorders
2012-01-01
The CO2 laser was invented in 1963 by Kumar Patel. Since the early 1970s, CO2 laser has proved to be an effective method of treatment for patients with several types of oral lesions, including early squamous cell carcinoma. Laser surgery of oral premalignant disorders is an effective tool in a complete management strategy which includes careful clinical follow-up, patient education to eliminate risk factors, reporting and biopsying of suspicious lesions and any other significant lesions. However, in a number of patients, recurrence and progression to malignancy remains a risk. CO2 laser resection has become the preferred treatment for small oral and oropharyngeal carcinomas. Laser resection does not require reconstructive surgery. There is minimal scarring and thus, optimum functional results can be expected. New and improved applications of laser surgery in the treatment of oral and maxillofacial/head and neck disorders are being explored. As more surgeons become experienced in the use of lasers and as our knowledge of the capabilities and advantages of this tool expands, lasers may play a significant role in the management of different pathologies. PMID:22546534
Rapid fibrin plug formation within cutaneous ablative fractional CO2 laser lesions.
Kositratna, Garuna; Evers, Michael; Sajjadi, Amir; Manstein, Dieter
2016-02-01
Ablative fractional laser procedures have been shown to facilitate topical drug delivery into the skin. Past studies have mainly used ex vivo models to demonstrate enhanced drug delivery and in vivo studies have investigated laser created channels over a time course of days and weeks rather than within the first few minutes and hours after exposures. We have noticed rapid in vivo fibrin plug formation within ablative fractional laser lesions impairing passage through the laser created channels. In vivo laser exposures were performed in a porcine model. A fractional CO2 laser (AcuPulse™ system, AcuScan 120™ handpiece, Lumenis, Inc., Yokneam, Israel) was programmed in quasi-continuous wave (QCW) mode, at 40W, 50 mJ per pulse, 5% coverage, nominal 120 µm spot size, 8 × 8 mm square pattern, 169 MTZs per scan. Six millimeters punch biopsies were procured at 0, 2, 5, 10, 15, 30, 60, 90 minutes after completion of each scan, then fixed in 10% formalin. 12 repeats were performed of each time point. Skin samples were processed for serial vertically cut paraffin sections (5 μm collected every 25 μm) then H&E and special immunohistochemistry staining for fibrin and platelet. Dimensions of Microscopic Treatment Zones (MTZs) and extent of fibrin plug were assessed and quantified histologically. Ex vivo laser exposures of the identical laser parameter were performed on porcine and human skin at different storage conditions. Histology procured at various predetermined time intervals after in vivo fractional CO2 laser exposures revealed a rapidly forming fibrin plug initiating at the bottom of the MTZ lesions. At longer time intervals, the fibrin plug was extending towards the superficial sections. Within the first 5 minutes, more than 25% length of the entire laser-ablated channel was filled with a fibrin plug. With increased time intervals, the cavity was progressively filled with a fibrin plug. At 90 minutes, more than 90% length of the entire laser-ablated channel was occluded. Ex vivo exposures failed to produce any significant fibrin plug formation. The current study has demonstrated rapid fibrin plug formation after ablative fractional laser procedures. It was shown that the passage through laser created pathways is critically time dependent for in vivo exposures. In contrast, ex vivo exposures do not exhibit such time dependent passage capacity. In particular, drug, substance, and cell delivery studies for ablative fractional laser treatments should take early fibrin plug formation into consideration and further investigate the impact on transdermal delivery. © 2015 Wiley Periodicals, Inc.
Thermographic study of laser on arteries.
Mnitentag, J; Marques, E F; Ribeiro, M P; Braga, G A; Navarro, M R; Veratti, A B; Armelin, E; Macruz, R; Jatene, A D
1987-01-01
We analyzed the different effects of CO2, Nd-YAG, and argon lasers on aorta by using a Thermovision infrared system that registered the laser interaction with mongrel dog aorta. The images (thermograms) obtained were processed by a computer, which associated each area of the same temperature with a determined color. These thermograms were compared to histological analysis of the respective samples and the following results were obtained: (1) After the application of each laser there is very little propagation of heat in tissue. (2) The CO2 laser makes tissue reach 100 degrees C in less than 0.05 seconds. (3) The heat dissipation time was higher with the Nd-YAG laser due to higher scattering on tissue. Based on this research we conclude that the CO2 laser was best absorbed, the Nd-YAG laser penetrated human tissue with the best results, and the argon laser had the most significant backscattering.
Strong-field physics with mid-infrared lasers
NASA Astrophysics Data System (ADS)
Pogorelsky, I. V.
2002-04-01
Mid-infrared gas laser technology promises to become a unique tool for research in strong-field relativistic physics. The degree to which physics is relativistic is determined by a ponderomotive potential. At a given intensity, a 10 μm wavelength CO2 laser reaches a 100 times higher ponderomotive potential than the 1 μm wavelength solid state lasers. Thus, we can expect a proportional increase in the throughput of such processes as laser acceleration, x-ray production, etc. These arguments have been confirmed in proof-of-principle Thomson scattering and laser acceleration experiments conducted at BNL and UCLA where the first terawatt-class CO2 lasers are in operation. Further more, proposals for the 100 TW, 100 fs CO2 lasers based on frequency-chirped pulse amplification have been conceived. Such lasers can produce physical effects equivalent to a hypothetical multi-petawatt solid state laser. Ultra-fast mid-infrared lasers will open new routes to the next generation electron and ion accelerators, ultra-bright monochromatic femtosecond x-ray and gamma sources, allow to attempt the study of Hawking-Unruh radiation, and explore relativistic aspects of laser-matter interactions. We review the present status and experiments with terawatt-class CO2 lasers, sub-petawatt projects, and prospective applications in strong-field science. .
Current status of lasers in soft tissue dental surgery.
Pick, R M; Colvard, M D
1993-07-01
The aims of this paper are to briefly describe laser physics, the types of lasers currently available for use on soft tissues focusing primarily on CO2 and Nd:YAG laser energies, the histological effects of lasers on oral tissues, laser safety, the clinical applications of lasers on oral soft tissues, and future directions. Of the two types of lasers currently available for dental applications, both the CO2 and Nd:YAG lasers can be used for frenectomies, ablation of lesions, incisional and excisional biopsies, gingivectomies, gingivoplasties, soft tissue tuberosity reductions, operculum removal, coagulation of graft donor sites, and certain crown lengthening procedures. The advantages of lasers include a relatively bloodless surgical and post-surgical course, minimal swelling and scarring, coagulation, vaporization, and cutting, minimal or no suturing, reduction in surgical time, and, in a majority of cases, much less or no post-surgical pain. CO2 lasers, compared to Nd:YAG are faster for most procedures, with less depth of tissue penetration and a well-documented history. There have been recent reports on the use of the Nd:YAG laser for periodontal scaling, gingival curettage, and root desensitization, but further research needs to be conducted. Both the CO2 and the Nd:YAG laser have limited use in conventional flap therapy.
Hsiao, Chien-Yu; Sung, Hsin-Ching; Hu, Sindy; Huang, Chun-Hsun
2016-07-01
Laser pretreatment of skin can be used to enable drugs used in dermatology to penetrate the skin to the depth necessary for their effect to take place. To compare the permeation of tranexamic acid after conventional non-fractionated ablative Er:YAG and CO2 laser pretreatment in a laser-aided transdermal delivery system. An erbium-doped yttrium aluminium garnet (Er:YAG) and a CO2 laser were used to pretreat dorsal porcine skin. Scanning electron microscopy was used to examine disruption of the skin surface. Confocal laser scanning microscopy was used to determine the depth of penetration of a reporter molecule (fluorescein isothiocyanate) into the skin. A Franz diffusion assembly was used to examine fluency-related increases in transdermal delivery of transexamic acid. Transdermal delivery of tranexamic acid increased as Er:YAG laser fluency increased. Transdermal delivery was higher when CO2 laser pretreatment was used than when Er:YAG laser pretreatment was used, but a "ceiling effect" was present and increasing the wattage did not cause a further increase in delivery. CO2 laser pretreatment also caused more extensive and deeper skin disruption than Er:YAG laser pretreatment. For conventional, non-fractionated ablative laser pretreatment, the Er:YAG laser would be an optimal choice to enhance transdermal penetration of transexamic acid.
STRONG FIELD PHYSICS WITH MID INFRARED LASERS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
POGORELSKY,I.V.
2001-08-27
Mid-infrared gas laser technology promises to become a unique tool for research in strong-field relativistic physics. The degree to which physics is relativistic is determined by a ponderomotive potential. At a given intensity, a 10 {micro}m wavelength CO{sub 2} laser reaches a 100 times higher ponderomotive potential than the 1 {micro}m wavelength solid state lasers. Thus, we can expect a proportional increase in the throughput of such processes as laser acceleration, x-ray production, etc. These arguments have been confirmed in proof-of-principle Thomson scattering and laser acceleration experiments conducted at BNL and UCLA where the first terawatt-class CO{sub 2} lasers aremore » in operation. Further more, proposals for the 100 TW, 100 fs CO{sub 2} lasers based on frequency-chirped pulse amplification have been conceived. Such lasers can produce physical effects equivalent to a hypothetical multi-petawatt solid state laser. Ultra-fast mid-infrared lasers will open new routes to the next generation electron and ion accelerators, ultra-bright monochromatic femtosecond x-ray and gamma sources, allow to attempt the study of Hawking-Unruh radiation, and explore relativistic aspects of laser-matter interactions. We review the present status and experiments with terawatt-class CO{sub 2} lasers, sub-petawatt projects, and prospective applications in strong-field science.« less
Roy, Soham; Smith, Lee P
2015-01-01
This study was designed to assess the ability of carbon dioxide (CO2) lasers and radiofrequency ablation devices (Coblator) (ArthoCare Corporation, Sunnyvale, CA) to ignite either a non-reinforced (polyvinylchloride) endotracheal tube (ETT) or an aluminum and fluoroplastic wrapped silicon ("laser safe") ETT at varying titrations of oxygen in a mechanical model of airway surgery. Non-reinforced and laser safe ETTs were suspended in a mechanical model imitating endoscopic airway surgery. A CO2 laser set at 5-30 watts was fired at the ETT at oxygen concentrations ranging from 21% to 88%. The process was repeated using a radiofrequency ablation (RFA) device. All trials were repeated to ensure accuracy. The CO2 laser ignited a fire when contacting a non-reinforced ETT in under 2 seconds at oxygen concentrations as low as 44%. The CO2 laser could not ignite a laser safe ETT under any conditions, unless it struck the non-reinforced distal tip of the ETT. With the RFA, a fire could not be ignited with either reinforced or non-reinforced ETTs. RFA presents no risk of ignition in simulated airway surgery. CO2 lasers should be utilized with a reinforced ETT or no ETT, as fires can easily ignite when lasers strike a non-reinforced ETT. Decreasing the fraction of inspired oxygen reduces the risk of fire. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Moskalenko, Konstantin L.; Sobolev, Nikolai V.; Adamovskay, Inna A.; Stepanov, Eugene V.; Nadezhdinskii, Alexander I.; McKenna-Lawlor, Susan
1994-01-01
Measurements of carbon monoxide and carbon dioxide concentrations by registration of high resolution absorption spectra are described. A fully automated diode laser system developed to simultaneously measure CO and CO2, with sensitivity for CO up to 50 ppb and CO2 up to 0.1 vol%, is described. Calculation of CO and CO2 concentrations was carried out on the base of a priori date on strength and broadening coefficients of detected absorption lines. Test procedures of such diode laser systems are described. Possible reasons affected on accuracy and reliability of obtained data (e.g., the value of diode lasers spontaneous radiation, the stability of CO content in a cell, etc.) for absolute and relative calibration procedure are discussed. The physiological level of CO concentration in the breath of non smokers and smokers under different ambient conditions of CO concentrations in the atmosphere (in Moscow and in Maynooth) are compared. Recent results on statistical studies of the behavior of CO concentrations as a function of breath holding time are represented.
Formation of surface nanolayers in chalcogenide crystals using coherent laser beams
NASA Astrophysics Data System (ADS)
Ozga, K.; Fedorchuk, A. O.; El-Naggar, A. M.; Albassam, A. A.; Kityk, V.
2018-03-01
We have shown a possibility to form laser modified surface nanolayers with thickness up to 60 nm in some ternary chalcogenide crystals (Ag3AsS3, Ag3SbS3, Tl3SbS3) The laser treatment was performed by two coherent laser beams split in a space. As the inducing lasers we have applied continuous wave (cw) Hesbnd Cd laser at wavelength 441 nm and doubled frequency cw Nd: YAG laser at 532 nm. The spectral energies of these lasers were higher with respect to the energy gaps of the studied crystals. The optical anisotropy was appeared and defected by monitoring of birefringence at probing wavelength of cw Hesbnd Ne laser at λ = 3390 nm. The changes of the laser stimulated near the surface layer morphology was monitored by TEM and AFM methods as well as by the reflected optical second harmonic generation at fundamental wavelength of microsecond CO2 laser generating at wavelength 10600 nm. This technique may open a new approach for the formation of the near the surface nanolayers in chalcogenides using external cw laser illumination.
Wandhöfer, A; Bally, G; Kauffmann, G; Karduck, A
1977-10-31
By comparing the effects of CO2- and Nd:YAG-laser radiation (mainly differing in wave-length by a factor of 10), a surgical instrument suitable for Otorhinolaryngology had to be found. The studies were performed on the rabbit's auricle in order to examine the effect of the laser irradiation mainly on the cartilage. The CO2-laser was found to be more efficient in cutting and caused less extended tissue damage than the Nd:YAG-laser. The latter seems to be more suitable for soft tissue surgery.
Synthesis of the Plasma Chemistry Occurring in High Power CO2 Lasers
1978-12-01
AFIT/GEP/PH/78D-13 44 SYNTHESIS OF THE PLASMA CHEMISTRY D D C OCCURRING IN HIGH POWER CO 2 LASERS ’Una CTHESIS David E. Toodle AFIT/GEP/PH/78D-13 2nd...inves- tivation is the plasma chemistry occurring in the laser discharge. These studies are ultimately related to the development of flowing and...aids in the understanding of plasma chemistry pro- cesses in the CO2 laser discharge. I would like to thank the whole staff of the Advanced Concepts
Wong, Yu-Tung; Finley, Charles C; Giallo, Joseph F; Buckmire, Robert A
2011-08-01
To introduce a novel method of combining robotics and the CO(2) laser micromanipulator to provide excellent precision and performance repeatability designed for surgical applications. Pilot feasibility study. We developed a portable robotic controller that appends to a standard CO(2) laser micromanipulator. The robotic accuracy and laser beam path repeatability were compared to six experienced users of the industry standard micromanipulator performing the same simulated surgical tasks. Helium-neon laser beam video tracking techniques were employed. The robotic controller demonstrated superiority over experienced human manual micromanipulator control in accuracy (laser path within 1 mm of idealized centerline), 97.42% (standard deviation [SD] 2.65%), versus 85.11% (SD 14.51%), P = .018; and laser beam path repeatability (area of laser path divergence on successive trials), 21.42 mm(2) (SD 4.35 mm(2) ) versus 65.84 mm(2) (SD 11.93 mm(2) ), P = .006. Robotic micromanipulator control enhances accuracy and repeatability for specific laser tasks. Computerized control opens opportunity for alternative user interfaces and additional safety features. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.
Peng, Wen Yu; Goldenstein, Christopher S; Mitchell Spearrin, R; Jeffries, Jay B; Hanson, Ronald K
2016-11-20
The development and demonstration of a four-color single-ended mid-infrared tunable laser-absorption sensor for simultaneous measurements of H2O, CO2, CO, and temperature in combustion flows is described. This sensor operates by transmitting laser light through a single optical port and measuring the backscattered radiation from within the combustion device. Scanned-wavelength-modulation spectroscopy with second-harmonic detection and first-harmonic normalization (scanned-WMS-2f/1f) was used to account for variable signal collection and nonabsorption losses in the harsh environment. Two tunable diode lasers operating near 2551 and 2482 nm were utilized to measure H2O concentration and temperature, while an interband cascade laser near 4176 nm and a quantum cascade laser near 4865 nm were used for measuring CO2 and CO, respectively. The lasers were modulated at either 90 or 112 kHz and scanned across the peaks of their respective absorption features at 1 kHz, leading to a measurement rate of 2 kHz. A hybrid demultiplexing strategy involving both spectral filtering and frequency-domain demodulation was used to decouple the backscattered radiation into its constituent signals. Demonstration measurements were made in the exhaust of a laboratory-scale laminar methane-air flat-flame burner at atmospheric pressure and equivalence ratios ranging from 0.7 to 1.2. A stainless steel reflective plate was placed 0.78 cm away from the sensor head within the combustion exhaust, leading to a total absorption path length of 1.56 cm. Detection limits of 1.4% H2O, 0.6% CO2, and 0.4% CO by mole were reported. To the best of the authors' knowledge, this work represents the first demonstration of a mid-infrared laser-absorption sensor using a single-ended architecture in combustion flows.
Hybrid Modes in Long Wavelength Free Electron Lasers
2010-12-01
response, including the time for reviewing instruction, searching existing data sources, gathering and maintaining the data needed, and completing and...diffraction along one axis, allowing free space diffraction along the other axis. We continue the analysis of the relativistic electron beam, co-propagating...control diffraction along one axis, allowing free space diffraction along the other axis. We continue the analysis of the relativistic electron beam, co
Effects of contaminants in CO2 lasers.
NASA Technical Reports Server (NTRS)
Smith, N. S.
1973-01-01
A theoretical model which includes the effects of contaminants is developed for the high flow electric discharge CO2-N2-He laser. The model couples the excitation and relaxation processes, CO2 dissociation, and negative ion formation with the flow processes. An analysis of the effects of CO, O2, NO, and N2O impurities on the average small signal gain is presented. CO decreases the gain by collisional depopulation of the upper laser level, and O2, NO, and N2O reduce the gain by decreasing the electron density by forming stable negative ions. In particular, N2O exhibits a strong quenching effect because of its large dissociation cross section for the formation of O(-).
Diffusion-cooled high-power single-mode waveguide CO2 laser for transmyocardial revascularization
NASA Astrophysics Data System (ADS)
Berishvili, I. I.; Bockeria, L. A.; Egorov, E. N.; Golubev, Vladimir S.; Galushkin, Michail G.; Kheliminsky, A. A.; Panchenko, Vladislav Y.; Roshin, A. P.; Sigaev, I. Y.; Vachromeeva, M. N.; Vasiltsov, Victor V.; Yoshina, V. I.; Zabelin, Alexandre M.; Zelenov, Evgenii V.
1999-01-01
The paper presents the results on investigations and development of multichannel waveguide CO2 laser with diffusion cooling of active medium excited by discharge of audio-frequency alternating current. The description of high-power single-mode CO2 laser with average beam power up to 1 kW is presented. The result of measurement of the laser basic parameters are offered, as well as the outcomes of performances of the laser head with long active zone, operating in waveguide mode. As an example of application of these laser, various capabilities a description of the developed medical system 'Genom' used in the transmyocardial laser revascularization (TMLR) procedure and clinical results of the possibilities of the TMLR in the surgical treatment are presented.
Laser abrasion for cosmetic and medical treatment of facial actinic damage
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, L.M.; Lask, G.P.; Glassberg, E.
1989-06-01
Previous studies have shown the carbon dioxide (CO/sub 2/) laser to be effective in the treatment of actinic cheilitis. After CO/sub 2/ laser abrasion, normal skin and marked cosmetic improvement of the lip were noted. In our study, twenty-three patients were treated with CO/sub 2/ laser abrasions for cosmetic improvement of facial lines and actinic changes. Pre- and postoperative histopathologic examinations were made on two patients. Preoperative examination of specimens from actinically damaged skin showed atypical keratinocytes in the basal layer of the epidermis, with overlying dense compact orthokeratosis and parakeratosis. Abundant solar elastosis was seen in the papillary dermis.more » Postoperative histologic specimens showed a normal-appearing epidermis with fibrosis in the papillary dermis and minimal solar elastosis (about four weeks after laser treatment). At present, various modalities are available for the regeneration of the aged skin, including chemical peels and dermabrasion. Significantly fewer complications were noted with CO/sub 2/ laser abrasion than with these methods. Thus, CO/sub 2/ laser abrasion can be useful in the cosmetic and medical treatment of the aged skin. Marked clinical and histologic improvement has been demonstrated.« less
Measurement of Concentration of CO2 in Atmosphere In Situ Based on TDLAS
NASA Astrophysics Data System (ADS)
Xin, Fengxin; Guo, Jinjia; Chen, Zhen; Liu, Zhishen
2014-11-01
As one of the main greenhouse gases in the atmosphere, CO2 has a significant impact on global climate change and the ecological environment. Because of close relationship between human activities and the CO2 emissions, it is very meaningful of detecting atmospheric CO2 accurately. Based on the technology of tunable diode laser absorption spectroscopy, the wavelength of distributed feedback laser is modulated, Fresnel lens is used as the receiving optical system, which receives the laser-beam reflected by corner reflector, and focuses the receiving laser-beam to the photoelectric detector. The second harmonic signal is received through lock-in amplifier and collected by AD data acquisition card, after that the system is built up. By choosing the infrared absorption line of CO2 at 1.57μm, the system is calibrated by 100% CO2 gas cell. The atmospheric CO2 in situ is measured with long open-path way. Furthermore, the results show that CO2 concentration decreases along time in the morning of day. It is proved that TDLAS technology has many advantages, including fast response, high sensitivity and resolution. This research provides a technique for monitoring secular change of CO2 in atmosphere.
Measurement of Concentration of CO2 in Atmosphere In Situ Based on TDLAS
NASA Astrophysics Data System (ADS)
Xin, Fengxin; Guo, Jinjia; Chen, Zhen; Liu, Zhishen
2014-11-01
As one of the main greenhouse gases in the atmosphere, CO2has a significant impact on global climate change and the ecological environment. Because of close relationship between human activities and the CO2 emissions, it is very meaningful of detecting atmospheric CO2accurately. Based on the technology of tunable diode laser absorption spectroscopy, the wavelength of distributed feedback laser is modulated, Fresnel lens is used as the receiving optical system, which receives the laser-beam reflected by corner reflector, and focuses the receiving laser-beam to the photoelectric detector. The second harmonic signal is received through lock-in amplifier and collected by AD data acquisition card, after that the system is built up.By choosing the infrared absorption line of CO2at 1.57μm, the system is calibrated by 100% CO2 gas cell. The atmospheric CO2 in situ is measured with long open-path way. Furthermore, the results show that CO2 concentration decreases along time in the morning of day. It is proved that TDLAS technology has many advantages, including fast response, high sensitivity and resolution. This research provides a technique for monitoring secular change of CO2 in atmosphere.
Fractional CO2 lasers for the treatment of atrophic acne scars: a review of the literature.
Magnani, Lauren Rose; Schweiger, Eric S
2014-04-01
This review examines the efficacy and safety of fractional CO2 lasers for the treatment of atrophic scarring secondary to acne vulgaris. We reviewed 20 papers published between 2008 and 2013 that conducted clinical studies using fractional CO2 lasers to treat atrophic scarring. We discuss the prevalence and pathogenesis of acne scarring, as well as the laser mechanism. The histologic findings are included to highlight the ability of these lasers to induce the collagen reorganization and formation that improves scar appearance. We considered the number of treatments and different laser settings to determine which methods achieve optimal outcomes. We noted unique treatment regimens that yielded superior results. An overview of adverse effects is included to identify the most common ones. We concluded that more studies need to be done using uniform treatment parameters and reporting in order to establish which fractional CO2 laser treatment approaches allow for the greatest scar improvement.
Zane, Cristina; Facchinetti, Elena; Arisi, Mariachiara; Ortel, Bernhard; Calzavara-Pinton, Piergiacomo
2017-07-01
Pulsed CO2 laser is a treatment of superficial basal cell carcinoma (sBCC) although robust clinical evidence has not been reported so far. The authors investigated efficacy, safety, time to wound healing, cosmetic outcome, patient satisfaction, and cost-effectiveness ratio of pulsed CO2 laser in comparison to cryotherapy and surgery. BCCs of the trunk and extremities were randomized to one of the treatments. After 90 days, efficacy and cosmetic outcome were assessed. Patients recorded the time to complete healing of the wound and scored their overall satisfaction. Two hundred forty patients were randomized. After 3 months, complete remission (CR) rate with pulsed CO2 laser was 78.8%. This was significantly lower than surgery, whereas the CR rate with cryotherapy was not significantly different. Cosmetic result was better with surgery. High satisfaction was reported by 65.0% of patients treated with CO2 ablation. Time of wound healing was significantly shorter with CO2 laser. In comparison to cryotherapy, pulsed CO2 laser showed no statistically significant difference in efficacy, cosmetic outcome, and patient satisfaction. Time to healing was shorter; the cost and cost-effectiveness ratio were similar. Surgery had the greatest efficacy rate. The main limitation of this study was the short duration of follow-up (3 months).
Outcomes of radiofrequency ablation (RFA) and CO2 laser for early glottic cancer.
Shuang, Yu; Li, Chao; Zhou, Xuan; Huang, Yongwang; Zhang, Lun
2016-01-01
In the present study, the voice and functional outcomes of radiofrequency ablation (RFA) and CO2 laser for early glottic cancer were evaluated. One hundred sixty eight patients with early glottic cancer from October 2007 to June 2015 were included. Ninety-seven patients underwent RFA and seventy-one patients underwent CO2 laser. The operation time and score of visual analog scale (VAS) for pain on the second day after surgery were recorded. The electronic laryngoscopy was performed at one week, one month and three months of postoperation. The operation time in RFA was shorter than that in CO2 laser (8.52±1.43min vs. 11.76±1.67min, P<0.05). There was no statistical difference in VAS scores between two operation methods (2.86±0.52 vs. 2.89±0.68, P>0.05). One month after operation, the mucosal recovery in RFA group was better than that in CO2 laser group (P<0.05). The alterations of acoustic parameters Jitter, Shimmer and HNR at three time points after operation showed statistical significances in both RFA and CO2 laser groups (P<0.05). The significant differences in acoustic parameters between two groups were also observed (P<0.05). There were no differences in three-year survival rate, local recurrence rate, recurrence rate with anterior commissure involvement and postoperative adhesion rate with anterior commissure between the patients with RFA and CO2 laser (P>0.05). No patient underwent tracheotomy and had symptoms of bucking, dyspnea, severe pain, hemoptysis and other serious complications. Both RFA and CO2 laser are safe and effective for the treatment of early glottic cancer. RFA has the advantage of quick voice recovery, low mucosa injury and short operation time, which is worthy for wide clinical application. Copyright © 2016 Elsevier Inc. All rights reserved.
CO2 laser and/or fluoride enamel treatment against in situ/ex vivo erosive challenge.
Jordão, Maísa Camillo; Forti, Gustavo Manzano; Navarro, Ricardo Scarparo; Freitas, Patrícia Moreira; Honório, Heitor Marques; Rios, Daniela
2016-01-01
This in situ/ex vivo study investigated the effect of CO2 laser irradiation and acidulated phosphate fluoride gel (APF) application, separately and in combination, on enamel resistance to erosion. During 2 experimental 5-day crossover phases, 8 volunteers wore intraoral appliances containing bovine enamel blocks which were submitted to four groups: 1st phase - control, untreated and CO2 laser irradiation, 2nd phase - fluoride application and fluoride application before CO2 laser irradiation. Laser irradiation was performed at 10.6 µm wavelength, 5 µs pulse duration and 50 Hz frequency, with average power input and output of 2.3 W and 2.0 W, respectively (28.6 J/cm2). APF gel (1.23%F, pH 3.5) was applied on enamel surface with a microbrush and left on for 4 minutes. Then, the enamel blocks were fixed at the intraoral appliance level. The erosion was performed extraorally 4 times daily for 5 min in 150 mL of cola drink. Enamel loss was measured profilometrically after treatment and after the in situ phase. The data were tested using one-way Repeated Measures Anova and Tukey's test (p<0.05). CO2 laser alone (2.00±0.39 µm) did not show any significantly preventive effect against enamel erosion when compared with the control group (2.41±1.20 µm). Fluoride treated enamel, associated (1.50±0.30 µm) or not (1.47±0.63 µm) with laser irradiation, significantly differed from the control. The APF application decreased enamel wear; however, CO2 laser irradiation did not enhance fluoride ability to reduce enamel wear.
CO2 laser and/or fluoride enamel treatment against in situ/ex vivo erosive challenge
JORDÃO, Maísa Camillo; FORTI, Gustavo Manzano; NAVARRO, Ricardo Scarparo; FREITAS, Patrícia Moreira; HONÓRIO, Heitor Marques; RIOS, Daniela
2016-01-01
ABSTRACT Objective This in situ/ex vivo study investigated the effect of CO2 laser irradiation and acidulated phosphate fluoride gel (APF) application, separately and in combination, on enamel resistance to erosion. Material and Methods During 2 experimental 5-day crossover phases, 8 volunteers wore intraoral appliances containing bovine enamel blocks which were submitted to four groups: 1st phase - control, untreated and CO2 laser irradiation, 2nd phase - fluoride application and fluoride application before CO2 laser irradiation. Laser irradiation was performed at 10.6 µm wavelength, 5 µs pulse duration and 50 Hz frequency, with average power input and output of 2.3 W and 2.0 W, respectively (28.6 J/cm2). APF gel (1.23%F, pH 3.5) was applied on enamel surface with a microbrush and left on for 4 minutes. Then, the enamel blocks were fixed at the intraoral appliance level. The erosion was performed extraorally 4 times daily for 5 min in 150 mL of cola drink. Enamel loss was measured profilometrically after treatment and after the in situ phase. The data were tested using one-way Repeated Measures Anova and Tukey's test (p<0.05). Results CO2 laser alone (2.00±0.39 µm) did not show any significantly preventive effect against enamel erosion when compared with the control group (2.41±1.20 µm). Fluoride treated enamel, associated (1.50±0.30 µm) or not (1.47±0.63 µm) with laser irradiation, significantly differed from the control. Conclusion The APF application decreased enamel wear; however, CO2 laser irradiation did not enhance fluoride ability to reduce enamel wear. PMID:27383703
NASA Astrophysics Data System (ADS)
Prakash, Shashi; Kumar, Subrata
2017-09-01
CO2 lasers are commonly used for fabricating polymer based microfluidic devices. Despite several key advantages like low cost, time effectiveness, easy to operate and no requirement of clean room facility, CO2 lasers suffer from few disadvantages like thermal bulging, improper dimensional control, difficulty to produce microchannels of other than Gaussian cross sectional shapes and inclined surface walls. Many microfluidic devices require square or rectangular cross-sections which are difficult to produce using normal CO2 laser procedures. In this work, a thin copper sheet of 40 μm was used as a mask above the PMMA (Polymethyl-methacrylate) substrate while fabricating the microchannels utilizing the raster scanning feature of the CO2 lasers. Microchannels with different width dimensions were fabricated utilizing a CO2 laser in with mask and without-mask conditions. A comparison of both the fabricating process has been made. It was found that microchannels with U shape cross section and rectangular cross-section can efficiently be produced using the with mask technique. In addition to this, this technique can provide perfect dimensional control and better surface quality of the microchannel walls. Such a microchannel fabrication process do not require any post-processing. The fabrication of mask using a nanosecond fiber laser has been discussed in details. An underwater laser fabrication method was adopted to overcome heat related defects in mask preparation. Overall, the technique was found to be easy to adopt and significant improvements were observed in microchannel fabrication.
NASA Astrophysics Data System (ADS)
Baranov, V. Yu; Dolgov, V. A.; Malyuta, D. D.; Mezhevov, V. S.; Semak, V. V.
1987-12-01
The profile of pulses emitted by a TEA CO2 laser with an unstable resonator changed as a result of interaction of laser radiation with the surface of a metal in the presence of a breakdown plasma. This influence of a target on laser operation and its possible applications in laser processing of materials are analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kupenko, I., E-mail: kupenko@esrf.fr; Strohm, C.; ESRF-The European Synchrotron, CS 40220, 38043 Grenoble Cedex 9
2015-11-15
Developments in pulsed laser heating applied to nuclear resonance techniques are presented together with their applications to studies of geophysically relevant materials. Continuous laser heating in diamond anvil cells is a widely used method to generate extreme temperatures at static high pressure conditions in order to study the structure and properties of materials found in deep planetary interiors. The pulsed laser heating technique has advantages over continuous heating, including prevention of the spreading of heated sample and/or the pressure medium and, thus, a better stability of the heating process. Time differentiated data acquisition coupled with pulsed laser heating in diamondmore » anvil cells was successfully tested at the Nuclear Resonance beamline (ID18) of the European Synchrotron Radiation Facility. We show examples applying the method to investigation of an assemblage containing ε-Fe, FeO, and Fe{sub 3}C using synchrotron Mössbauer source spectroscopy, FeCO{sub 3} using nuclear inelastic scattering, and Fe{sub 2}O{sub 3} using nuclear forward scattering. These examples demonstrate the applicability of pulsed laser heating in diamond anvil cells to spectroscopic techniques with long data acquisition times, because it enables stable pulsed heating with data collection at specific time intervals that are synchronized with laser pulses.« less
1995-03-01
"Holmium:YAG (Ho:YAG)" is the shorthand name for a family of solid-state lasers that use the doping element holmium in a laser crystal (e.g., YAG [yttrium-aluminum-garnet]) and that emit energy at approximately 2.1 microns. This wavelength is relatively new to medicine and has been used in laser surgery for only about the last six years. Like the carbon dioxide (CO2) laser when it was first used clinically, the Ho:YAG laser is poised for rapid and wide-spread use. Ho:YAG lasers, like CO2 lasers, offer precise cutting with minimal damage to adjacent tissue; however, unlike CO2 lasers, they also offer fiberoptic delivery (which is ideal for endoscopic use) and the ability to treat tissue in a liquid-filled environment (e.g., saline, blood). The initial specialty for which the Ho:YAG laser was used was arthroscopic surgery, especially diskectomy. Today, it is effectively used in many surgical specialties, including general surgery, urology, laparoscopy, neurosurgery, lithotripsy, angioplasty, orthopedic surgery (which includes procedures such as meniscectomy, bone sculpting [may also be performed in plastic surgery], and some experimental surgery, such as cartilage shrinking to tighten loose joints), and dentistry. Because of its broad range of potential applications, it has been called the "Swiss Army Knife" of lasers. High-powered Ho:YAG lasers, which enable surgeons to work more quickly and cut more smoothly, have been made available only within the last three years (units offering > 20 W) to 18 months (units offering > 60 W). Because of this rapid increase, high-powered units are still relatively expensive, and it is not yet clear whether maximum power outputs will continue to increase or whether the cost of higher-power units will begin to come down. Although low-power and high-power Ho:YAG lasers can be used for the same procedures, their different ranges of possible clinical techniques make them better suited to different applications: low-power units are preferable for small-joint and some head-and-neck surgeries or for office use, and high-power units are more suitable for use in major surgery, such as gastrointestinal surgery or surgery in large joints. This evaluation includes two units at both ends of the Ho:YAG power spectrum--one 10 W and one 60 W--and thus provides a guide to evaluating other Ho:YAG lasers that are currently available or that will be entering the market.(ABSTRACT TRUNCATED AT 400 WORDS)
Photolasertherapy for the treatment of infections in neurosurgery: experimental and clinical study
NASA Astrophysics Data System (ADS)
Lombard, Gian F.
1996-12-01
At the first time, the CO2 laser was utilised in infective neurosurgical pathology as a surgical cutting instrument to remove inflammatory pseudomembranes in chronic osteomyelitis, and as a vaporising instmment on the dura mater surface. Successively, the instrument, defocused and at a low power, was used for prolonged and diffuse photo coagulation ofthe surgical cavity, particularly, ofthe dural surface and ofthe osteomyelitic bone edges, with the aim to sterilise tissues. So, we saw a shortening of the average time of wound healing and a lack of recurrence of the septic pathology. Then, we have treated, with CO2 laser, intracranial infective pathology: i.e. primary abscesses, capsulated or not, circumscribed purulent encephalitis, secondary abscesses in surgical cavities (patients operated for intracranial hematomas and tumors). In these cases we have obtained a lack of septic recurrences and an improvement ofneurological post-operative course. Thank to these results, we have continued to use laser in infective pathology; for giving an experimental support to these results we have carried on researches in vivo (on the experimental animal) to see the interaction between the laser and inflammatory tissue, and in vitro (on bacterial culture: in solid and liquid media) to see the laser effect on the bacterial cell. The bacterial cell has been also sensibiized to the photo dynamic effect of the laser (Argon, He-Ne), with hematoporphyrin. The goal of these experiments is to understand the role of thermal, photochemical, and mechanic resonance laser effects in the interaction between laser radiation and bacterial cell.
Raman Spectroscopic Measurements of Co2 Dissolved in Seawater for Laser Remote Sensing in Water
NASA Astrophysics Data System (ADS)
Somekawa, Toshihiro; Fujita, Masayuki
2016-06-01
We examined the applicability of Raman lidar technique as a laser remote sensing tool in water. The Raman technique has already been used successfully for measurements of CO2 gas dissolved in water and bubbles. Here, the effect of seawater on CO2 Raman spectra has been evaluated. A frequency doubled Q-switched Nd:YAG laser (532 nm) was irradiated to CO2 gas dissolved in a standard seawater. In seawater, the Raman signals at 984 and 1060-1180 cm-1 from SO42- were detected, which shows no spectral interference caused by Raman signals derived from CO2.
Rink, John P.
1977-01-01
The disclosure relates to a pulsed gas laser comprising an optical resonant cavity, a CO.sub.2 lasing medium, structure for containing the CO.sub.2 lasing medium within the optical cavity and a device for causing a population inversion in the lasing medium, with a novel improvement comprising structure for causing a laser pulse comprising a wavelength in the near 14 .mu.m and near 16 .mu.m range. The structure for cooling the CO.sub.2 lasing medium to less than about -40.degree. C as well is a structure for pumping the maximum inversion of CO.sub.2 molecules within the lasing medium by minimizing the population in the 010 level.
NASA Astrophysics Data System (ADS)
Ma, Liu Hao; Lau, Lok Yin; Ren, Wei
2017-03-01
We report in situ measurements of non-uniform temperature, H2O and CO2 concentration distributions in a premixed methane-air laminar flame using tunable diode laser absorption spectroscopy (TDLAS). A mid-infrared, continuous-wave, room-temperature interband cascade laser (ICL) at 4183 nm was used for the sensitive detection of CO2 at high temperature.The H2O absorption lines were exploited by one distributed feedback (DFB) diode laser at 1343 nm and one ICL at 2482 nm to achieve multi-band absorption measurements with high species concentration sensitivity, high temperature sensitivity, and immunity to variations in ambient conditions. A novel profile-fitting function was proposed to characterize the non-uniform temperature and species concentrations along the line-of-sight in the flame by detecting six absorption lines of CO2 and H2O simultaneously. The flame temperature distribution was measured at different heights above the burner (5-20 mm), and compared with the thermocouple measurement with heat-transfer correction. Our TDLAS measured temperature of the central flame was in excellent agreement (<1.5% difference) with the thermocouple data.The TDLAS results were also compared with the CFD simulations using a detailed chemical kinetics mechanism (GRI 3.0) and considering the heat loss to the surroundings.The current CFD simulation overpredicted the flame temperature in the gradient region, but was in excellent agreement with the measured temperature and species concentration in the core of the flame.
Monolithic thermally bonded Er3+, Yb3+:glass/Co2+:MgAl2O4 microchip lasers
NASA Astrophysics Data System (ADS)
Mlynczak, Jaroslaw; Belghachem, Nabil
2015-12-01
The highest ever reported 10 kW peak power in monolithic thermally bonded Er3+, Yb3+:glass/Co2+:MgAl2O4 microchip laser was achieved. To show the superiority of monolithic microchip lasers over those with external mirrors the laser generation characteristics of the same samples in both cases were compared.
Intense laser beams; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1992
NASA Technical Reports Server (NTRS)
Wade, Richard C. (Editor); Ulrich, Peter B. (Editor)
1992-01-01
Various papers on intense laser beams are presented. Individual topics addressed include: novel methods of copper vapor laser excitation, UCLA IR FEL, lasing characteristics of a large-bore copper vapor laser (CVL), copper density measurement of a large-bore CVL, high-power XeCl excimer laser, solid state direct-drive circuit for pumping gas lasers, united energy model for FELs, intensity and frequency instabilities in double-mode CO2 lasers, comparison of output power stabilities of CO and CO2 lasers, increasing efficiency of sealed-off CO lasers, thermal effects in singlet delta oxygen generation, optical extraction from the chemical oxygen-iodine laser medium, generation and laser diagnostic analysis of bismuth fluoride. Also discussed are: high-Q resonator design for an HF overtone chemical lasers, improved coatings for HF overtone lasers, scaled atmospheric blooming experiment, simulation on producing conjugate field using deformable mirrors, paraxial theory of amplitude correction, potential capabilities of adaptive optical systems in the atmosphere, power beaming research at NASA, system evaluations of laser power beaming options, performance projections for laser beam power to space, independent assessment of laser power beaming options, removal of atmospheric CFCs by lasers, efficiency of vaporization cutting by CVL.
Radmanesh, Mohammad; Rafiei, Zohreh
2015-04-01
The eyebrow tattoo removal using Q-switched lasers is usually prolonged. Other modalities may be required to enhance the efficacy and shorten the treatment course. To compare the efficacy of Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) laser alone versus combination of Q-switched Nd:YAG and Ultrapulse CO2 lasers for eyebrow tattoo removal after a single session. After local anesthesia, the right eyebrow of 20 patients was treated with Ultrapulse CO2 laser with the parameters of 4 J/cm(2) and 3.2 J/cm(2) for the first and the second passes. Both eyebrows were then treated with 1064-nm and 532-nm Q-switched Nd:YAG laser. The spot size and pulse duration were 3 mm and 5 nanoseconds for both wavelengths, and the fluence was 7 J/cm(2) for 1064 nm and 3 J/cm (2) for 532 nm. The side treated with combination of Q-switched Nd:YAG and CO2 lasers improved 75-100% in 6 of 20 patients versus only 1 of 20 in the side treated with Q-switched Nd:YAG alone. Similarly, the right side in 13 of 20 patients showed more than 50% improvement with combination therapy versus the left side (the monotherapy side), where only 6 of 20 cases showed more than 50% improvement. The Mann-Whitney test was 2.85 for the right side and 1.95 for the left side (P value = 0.007). Using Ultra pulse CO2 laser enhances the efficacy of Q-switched Nd:YAG laser in eyebrow tattoo removal.
A new second-puncture probe for CO2 laser laparoscopy.
Daniell, J F; Herbert, C M
1985-02-01
A new second-puncture probe system was designed for aiming and firing the CO2 laser under laparoscopic control. The probe allows simultaneous suction of the smoke from vaporization and insufflation of fresh CO2 for maintenance of an adequate pneumoperitoneum during use. A 200-mm focusing lens attaches the probe to any surgical CO2 laser with an articulated arm. The new probe is 10 cm shorter than standard probes, allowing the application of a wider range of power densities during laser laparoscopy and making surgery easier to perform. Our initial experiences with this new instrument have involved both laboratory animals and patients with endometriosis, adnexal adhesions and distal tubal obstruction.
Multiline CO2 laser with Q-switching for generation of terahertz radiation
NASA Astrophysics Data System (ADS)
Ionin, A. A.; Kinyaevskiy, I. O.; Klimachev, Yu M.; Stepanishchev, V. V.; Khafizov, I. Zh
2017-12-01
In this paper we consider the method of obtaining THz radiation by difference frequency generation (DFG) of multiline CO2 laser. For this purpose a multiline CO2 laser with Q-switching was created. The three strongest lines, 9 R(18), 9 P(20) and 9 P(22) with wavelengths ∼9.28, ∼9.55 and ∼9.57 μm respectively, held 85% of CO2 laser power, and can be used to obtain difference frequency at a wavelength of ∼310 μm. DFG of other spectral lines fall within the range of 263 ÷ 8100 μm. Different nonlinear crystals for DFG and filters to separate THz radiation were considered.
Combined Tin-Containing Fluoride Solution and CO2 Laser Treatment Reduces Enamel Erosion in vitro.
Esteves-Oliveira, Marcella; Witulski, Nadine; Hilgers, Ralf-Dieter; Apel, Christian; Meyer-Lueckel, Hendrik; Eduardo, Carlos de Paula
2015-01-01
The aim of this in vitro study was to evaluate the effect of combined CO2 laser and tin-containing fluoride treatment on the formation and progression of enamel erosive lesions. Ninety-six human enamel samples were obtained, stored in thymol solution and, after surface polishing, randomly divided into 6 different surface treatment groups (n = 16 in each group) as follows: no treatment, control (C); one CO2 laser irradiation (L1); two CO2 laser irradiations (L2); daily application of fluoride solution (F); combined daily fluoride solution + one CO2 laser irradiation (L1F), and combined daily fluoride solution + two CO2 laser irradiations (L2F). Laser irradiation was performed at 0.3 J/cm2 (5 µs/226 Hz/10.6 µm) on day 1 (L1) and day 6 (L2). The fluoride solution contained AmF/NaF (500 ppm F), and SnCl2 (800 ppm Sn) at pH 4.5. After surface treatment the samples were submitted to an erosive cycling over 10 days, including immersion in citric acid (2 min/0.05 M/pH = 2.3) 6 times daily and storage in remineralization solution (≥1 h) between erosive attacks. At the end of each cycling day, the enamel surface loss (micrometers) was measured using a 3D laser profilometer. Data were statistically analyzed by means of a 2-level mixed effects model and linear contrasts (α = 0.05). Group F (-3.3 ± 2.0 µm) showed significantly lower enamel surface loss than groups C (-27.22 ± 4.1 µm), L1 (-18.3 ± 4.4 µm) and L2 (-16.3 ± 5.3 µm) but higher than L1F (-1.0 ± 4.4 µm) and L2F (1.4 ± 3.2 µm, p < 0.05). Under the conditions of this in vitro study, the tin-containing fluoride solution caused 88% reduction of enamel surface loss, while its combination with CO2 laser irradiation at 0.3 J/cm2 hampered erosive loss almost completely. © 2015 S. Karger AG, Basel.
High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement
NASA Technical Reports Server (NTRS)
Singh, Uprendra N.; Bai, Yingxin; Yu, Jirong; Petros, Mulugeta; Petzar, Paul J.; Trieu, Bo C.; Lee, Hyung
2009-01-01
A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.
NASA Astrophysics Data System (ADS)
Uno, Kazuyuki; Jitsuno, Takahisa
2018-05-01
In a longitudinally excited CO2 laser that had a 45 cm-long discharge tube with a 1:1:2 mixture of CO2/N2/He gas at a pressure of 3.0 kPa, we realized the generation of a short laser pulse with a spike pulse width of about 200 ns and a pulse tail length of several tens of microseconds, control of the energy ratio of the spike pulse part to the pulse tail part in the short laser pulse, the generation of a long laser pulse with a pulse width of several tens of microseconds, and control of the pulse width in the long laser pulse, by using four types of excitation circuits in which the capacitance was adjusted. In the short laser pulse, the energy ratio was in the range 1:14-1:112. In the long laser pulse, the pulse width was in the range 25.7-82.7 μs.
Development of a Pulsed 2-micron Laser Transmitter for CO2 Sensing from Space
NASA Technical Reports Server (NTRS)
Singh, Upendra N.; Yu, Jirong; Bai, Yingxin; Petros, Mulugeta; Menzies, Robert T.
2011-01-01
NASA Langley Research Center (LaRC), in collaboration with NASA Jet Propulsion Laboratory (JPL), is engaged in the development and demonstration of a highly efficient, versatile, 2-micron pulsed laser that can be used in a pulsed Differential Absorption Lidar (DIAL)/Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution CO2 measurements to investigate sources, sinks, and fluxes of CO2. This laser transmitter will feature performance characteristics needed for an ASCENDS system that will be capable of delivering the CO2 measurement precision required by the Earth Science Decadal Survey (DS).
Lin, Bing; Ismail, Syed; Wallace Harrison, F; Browell, Edward V; Nehrir, Amin R; Dobler, Jeremy; Moore, Berrien; Refaat, Tamer; Kooi, Susan A
2013-10-10
The focus of this study is to model and validate the performance of intensity-modulated continuous-wave (IM-CW) CO(2) laser absorption spectrometer (LAS) systems and their CO(2) column measurements from airborne and satellite platforms. The model accounts for all fundamental physics of the instruments and their related CO(2) measurement environments, and the modeling results are presented statistically from simulation ensembles that include noise sources and uncertainties related to the LAS instruments and the measurement environments. The characteristics of simulated LAS systems are based on existing technologies and their implementation in existing systems. The modeled instruments are specifically assumed to be IM-CW LAS systems such as the Exelis' airborne multifunctional fiber laser lidar (MFLL) operating in the 1.57 μm CO(2) absorption band. Atmospheric effects due to variations in CO(2), solar radiation, and thin clouds, are also included in the model. Model results are shown to agree well with LAS atmospheric CO(2) measurement performance. For example, the relative bias errors of both MFLL simulated and measured CO(2) differential optical depths were found to agree to within a few tenths of a percent when compared to the in situ observations from the flight of 3 August 2011 over Railroad Valley (RRV), Nevada, during the summer 2011 flight campaign. In addition, the horizontal variations in the model CO(2) differential optical depths were also found to be consistent with those from MFLL measurements. In general, the modeled and measured signal-to-noise ratios (SNRs) of the CO(2) column differential optical depths (τd) agreed to within about 30%. Model simulations of a spaceborne IM-CW LAS system in a 390 km dawn/dusk orbit for CO(2) column measurements showed that with a total of 42 W of transmitted power for one offline and two different sideline channels (placed at different locations on the side of the CO(2) absorption line), the accuracy of the τd measurements for surfaces similar to the playa of RRV, Nevada, will be better than 0.1% for 10 s averages. For other types of surfaces such as low-reflectivity snow and ice surfaces, the precision and bias errors will be within 0.23% and 0.1%, respectively. Including thin clouds with optical depths up to 1, the SNR of the τd measurements with 0.1 s integration period for surfaces similar to the playa of RRV, Nevada, will be greater than 94 and 65 for sideline positions placed +3 and +10 pm, respectively, from the CO(2) line center at 1571.112 nm. The CO(2) column bias errors introduced by the thin clouds are ≤0.1% for cloud optical depth ≤0.4, but they could reach ∼0.5% for more optically thick clouds with optical depths up to 1. When the cloud and surface altitudes and scattering amplitudes are obtained from matched filter analysis, the cloud bias errors can be further reduced. These results indicate that the IM-CW LAS instrument approach when implemented in a dawn/dusk orbit can make accurate CO(2) column measurements from space with preferential weighting across the mid to lower troposphere in support of a future ASCENDS mission.
NASA Astrophysics Data System (ADS)
Nadezhdinsky, A. I.; Ponurovsky, Ya. Ya.; Shapovalov, Y. P.; Popov, I. P.; Stavrovsky, D. B.; Khattatov, V. U.; Galaktionov, V. V.; Kuzmichev, A. S.
2012-11-01
The Federal Agency for Hydrometeorology of the Russian Federation created the flying laboratory on board the passenger airplane Yak-42D for geophysical monitoring of the environment, including aircraft measurements of vertical concentrations of greenhouse gases in the troposphere. Within the limits of this project, General Physics Institute of the Russian Academy of Science developed airborne tunable diode laser spectrometer (TDLS) on the basis of diode lasers of a near-IR range for measurement of the altitude profiles of CO2, CH4, H2O and its isotopes. TDLS complex was integrated aboard in standard 19-in. rack. Air samples, taken over an aircraft on the pipeline, were injected into the optical cell. Using the system of inflow and heating, the air was set laminar with a flowrate of 0.2 l/s at a reduced pressure of 100 mbar for detecting narrow absorption lines of water vapor isotopes. For registration of the absorption spectra and for the measurement of greenhouse gas concentrations in online mode, modulation-correlation technique was used. Diode laser spectrometer output data were transferred to the airborne central computer. Sensitivity of TDLS measurements was 20-30 ppm for water, 3-4 ppm for CO2 and 20-25 ppb for CH4. Time of one-unit measurement is about 30 ms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeLoach, L.D.; Page, R.H.; Wilke, G.D.
The absorption and emission properties of transition metal (TM)-doped Zinc chalcogenides have been investigated to understand their potential application as room-temperature, mid-infrared tunable laser media. Crystals of ZnS, ZnSe, and ZnTe, individually doped with Cr{sup 2+}, Co{sup 2+}, Ni{sup 2+}, or Fe{sup 2+}, have been evaluated. The absorption and emission properties are presented and discussed in terms of the energy levels from which they arise. The absorption spectra of the crystals studied exhibit strong bands between 1.4 and 2.0 {micro}m which overlap with the output of strained-layer InGaAs diodes. The room-temperature emission spectra reveal wide-band emissions from 2--3 {micro}m formore » Cr and from 2.8--1.0 {micro}m for Co. Laser demonstrations of Cr:ZnS and Cr:ZnSe have been performed in a laser-pumped laser cavity with a Co:MgF{sub 2} pump laser. The output of both lasers were determined to peak at wavelengths near 2.35 {micro}m, and both lasers demonstrated a maximum slope efficiency of approximately 20%. Based on these initial results, the Cr{sup 2+} ion is predicted to be a highly favorable laser ion for the mid-IR when doped into the zinc chalcogenides; Co{sup 2+} may also serve usefully, but laser demonstrations yet remain to be performed.« less
Mikkelsen, Peter Riis; Dufour, Deirde Nathalie; Zarchi, Kian; Jemec, Gregor B E
2015-02-01
Hidradenitis suppurativa (HS) is a debilitating disease and is difficult to treat. Validation of surgical techniques is therefore of great importance in the management of HS. Carbon dioxide (CO2) laser evaporation has been shown effective, but larger-scale studies are scarce. To determine the recurrence rate, time to recurrence, and factors influencing disease recurrence in skin treated with CO2 laser evaporation, and healing by secondary intention; and patients' satisfaction with treatment. Fifty-eight patients treated with CO2 laser evaporation were interviewed regarding recurrence and satisfaction after a mean of 25.7 months. Seventeen of 58 (29%) reported recurrence of HS lesions within the borders of the treated areas after a mean of 12.7 months. Obesity was a risk factor for recurrence with a hazard ratio of 4.53. Fifty-five patients (95%) reported some or great improvement, and 91% would recommend the CO2 laser surgery to other HS patients. This study supports the claim that CO2 laser treatment is an effective modality for recurrent HS lesions in a majority of patients. The authors identified obesity as a risk factor for recurrence. Self-reported satisfaction is high, and only 3 of 58 report no change in the condition. None reported a worsening.
Hao, L; Lawrence, J; Phua, Y F; Chian, K S; Lim, G C; Zheng, H Y
2005-04-01
An effective and novel technique for improving the biocompatibility of a biograde 316 LS stainless steel through the application of CO(2) laser treatment to modify the surface properties of the material is described herein. Different surface properties, such as surface roughness, surface oxygen content, and surface energy for CO(2) laser-treated 316 LS stainless steel, untreated, and mechanically roughened samples were analyzed, and their effects on the wettability characteristics of the material were studied. It was found that modification of the wettability characteristics of the 316 LS stainless steel following CO(2) laser treatment was achieved. This improvement was identified as being mainly due to the change in the polar component of the surface energy. One-day cell adhesion tests showed that cells not only adhered and spread better, but also grew faster on the CO(2) laser-treated sample than on either the untreated or mechanically roughened sample. Further, compared with the untreated sample, MTT cell proliferation analysis revealed that the mechanically roughed surface resulted in a slight enhancement, and CO(2) laser treatment brought about a significant increase in cell proliferation. An increase in the wettability of the 316 LS stainless steel was observed to positively correlate with the cell proliferation. (c) 2004 Wiley Periodicals, Inc.
Fractional CO2 laser for vulvovaginal atrophy (VVA) dyspareunia relief in breast cancer survivors.
Pieralli, Annalisa; Fallani, Maria Grazia; Becorpi, Angelamaria; Bianchi, Claudia; Corioni, Serena; Longinotti, Manuela; Tredici, Zelinda; Guaschino, Secondo
2016-10-01
The aim of this study was to evaluate the efficacy of fractional CO2 laser therapy in breast cancer survivors as a therapeutic method for vulvovaginal atrophy (VVA) dyspareunia. 50 patients (mean age 53.3 years) underwent fractional microablative CO2 laser treatment for dyspareunia in oncological menopause (mean time of menopause 6.6 years). The Gloria Bachmann's Vaginal Health Index (VHI) score was chosen as system to evaluate the presence of VVA and its improvement after the treatment. Intensity of dyspareunia was evaluated using a visual analog scale (VAS). Data indicated a significant improvement in VVA dyspareunia (p < 1.86e-22) in breast cancer survivors who had undergone 3 sessions of vaginal fractional CO2 laser treatment. Moreover, VHI scores were significantly higher 30 days post-treatment (T4) (p < 0.0001). 76 % of patients were satisfied or very satisfied with the treatment results. The majority (52 %) of patients were satisfied after a long-term follow-up (mean time 11 months). No adverse events due to fractional CO2 laser treatment occurred. The treatment with fractionated CO2 laser appeared to be a feasible and effective treatment for VVA dyspareunia in breast cancer survivors with contraindications to hormonal treatments.
The dynamics of a surface plasma generated by an independent source in the field of laser emission
NASA Astrophysics Data System (ADS)
Kovalev, A. S.; Popov, A. M.; Seleznev, B. V.; Feoktistov, V. A.
1986-09-01
A study is made of the evolution of a plasma formation generated by a high-power short pulse of an Nd laser on a metal surface, with the relatively weak emission of a CO2 laser focused on the surface. The thresholds of a sustained breakdown plasma are measured as a function of the plasma-generating pulse energy. The dynamics of plasma front propagation along the target surface and in the direction opposite to the laser beam direction is investigated. It is shown that the use of an additional laser with an energy less than that of the CO2 laser by 2-3 orders of magnitude makes it possible to generate a surface plasma capable of absorbing and transferring to the target a significantly greater fraction of the CO2 laser energy.
Seino, Priscila Yumi; Freitas, Patrícia Moreira; Marques, Márcia Martins; de Souza Almeida, Fernanda Campos; Botta, Sérgio Brossi; Moreira, Maria Stella Nunes Araújo
2015-02-01
One possible undesirable consequence of orthodontic therapy is the development of incipient caries lesions of enamel around brackets. The aim of this study was to compare the effects of CO2 (λ = 10.6 μm) and Nd:YAG (λ = 1,064 nm) lasers associated or not with topical fluoride application on the prevention of caries lesions around brackets. Brackets were bonded to the enamel of 65 premolars. The experimental groups (n = 13) were: G1--application of 1.23% acidulated fluoride phosphate gel (AFP, control); G2--Nd:YAG laser irradiation (0.6 W, 84.9 J/cm(2), 10 Hz, 110 μs, contact mode); G3--Nd:YAG laser irradiation associated with AFP; G4--CO2 laser irradiation (0.5 W, 28.6 J/cm(2), 50 Hz, 5 μs, and 10 mm focal distance); and G5--CO2 laser irradiation associated with AFP. Quantitative light-induced fluorescence was used to assess enamel demineralization. The data were statistically compared (α = 5%). The highest demineralization occurred in the Nd:YAG laser group (G2, 26.15% ± 1.94). The demineralization of all other groups was similar to that of the control group. In conclusion, CO2 laser alone was able to control enamel demineralization around brackets at the same level as that obtained with topical fluoride application.
NASA Astrophysics Data System (ADS)
Browell, E. V.; Dobler, J. T.; Kooi, S. A.; Fenn, M. A.; Choi, Y.; Vay, S. A.; Harrison, F. W.; Moore, B.
2011-12-01
This paper discusses the latest flight test results of a multi-frequency intensity-modulated (IM) continuous-wave (CW) laser absorption spectrometer (LAS) that operates near 1.57 μm for remote CO2 column measurements. This IM-LAS system is under development for a future space-based mission to determine the global distribution of regional-scale CO2 sources and sinks, which is the objective of the NASA Active Sensing of CO2 Emissions during Nights, Days, and Seasons (ASCENDS) mission. A prototype of the ASCENDS system, called the Multi-frequency Fiber Laser Lidar (MFLL), has been flight tested in eleven airborne campaigns since May 2005. This paper compares the most recent results obtained during the 2010 and 2011 UC-12 and DC-8 flight tests, where MFLL remote CO2 column measurements were evaluated against airborne in situ CO2 profile measurements traceable to World Meteorological Organization standards. The major change to the MFLL system in 2011 was the implementation of several different IM modes, which could be quickly changed in flight, to directly compare the precision and accuracy of MFLL CO2 measurements in each mode. The different IM modes that were evaluated included "fixed" IM frequencies near 50, 200, and 500 kHz; frequencies changed in short time steps (Stepped); continuously swept frequencies (Swept); and a pseudo noise (PN) code. The Stepped, Swept, and PN modes were generated to evaluate the ability of these IM modes to desensitize MFLL CO2 column measurements to intervening optically thin aerosols/clouds. MFLL was flown on the NASA Langley UC-12 aircraft in May 2011 to evaluate the newly implemented IM modes and their impact on CO2 measurement precision and accuracy, and to determine which IM mode provided the greatest thin cloud rejection (TCR) for the CO2 column measurements. Within the current hardware limitations of the MFLL system, the "fixed" 50 kHz results produced similar SNR values to those found previously. The SNR decreased as expected with increasing IM frequency with the SNR(500 kHz) equal to 31% of SNR(50 kHz). The absolute accuracy of the 50 kHz CO2 measurement showed a previously observed altitude-dependent trend that was greatly reduced at 200 kHz. Laboratory experiments have duplicated this effect which results mainly from IM frequency cross talk between LAS wavelengths in the erbium-doped fiber amplifier (EDFA) and which is reduced when operating at higher IM frequencies. Performance of the Stepped, Swept, and PN modes were evaluated in close time proximity to each other, and these results will be discussed in this paper. A second series of ASCENDS flight tests were conducted on the NASA DC-8 from 25 July to 12 August 2011 over similar local land and ocean targets as in 2010 and with additional long-range flights planned over the corn fields of Iowa, forests in northern Wisconsin, and ice fields of southeastern Alaska. MFLL CO2 measurement results from this field campaign will also be presented.
Waibel, Jill S; Rudnick, Ashley; Nousari, Carlos; Bhanusali, Dhaval G
2016-01-01
Topical drug delivery is the foundation of all dermatological therapy. Laser-assisted drug delivery (LAD) using fractional ablative laser is an evolving modality that may allow for a greater precise depth of penetration by existing topical medications, as well as more efficient transcutaneous delivery of large drug molecules. Additional studies need to be performed using energy-driven methods that may enhance drug delivery in a synergistic manner. Processes such as iontophoresis, electroporation, sonophoresis, and the use of photomechanical waves aid in penetration. This study evaluated in vivo if there is increased efficacy of fractional CO2 ablative laser with immediate acoustic pressure wave device. Five patients were treated and biopsied at 4 treatment sites: 1) topically applied aminolevulinic acid (ALA) alone; 2) fractional ablative CO2 laser and topical ALA alone; 3) fractional ablative CO2 laser and transdermal acoustic pressure wave device delivery system; and 4) topical ALA with transdermal delivery system. The comparison of the difference in the magnitude of diffusion with both lateral spread of ALA and depth diffusion of ALA was measured by fluorescence microscopy. For fractional ablative CO2 laser, ALA, and transdermal acoustic pressure wave device, the protoporphyrin IX lateral fluorescence was 0.024 mm on average vs 0.0084 mm for fractional ablative CO2 laser and ALA alone. The diffusion for the acoustic pressure wave device was an order of magnitude greater. We found that our combined approach of fractional ablative CO2 laser paired with the transdermal acoustic pressure wave device increased the depth of penetration of ALA.
Generation of energetic, picosecond seed pulses for CO2 laser using Raman shifter
NASA Astrophysics Data System (ADS)
Welch, Eric; Tochitsky, Sergei; Joshi, Chan
2017-03-01
We present a new concept for generating 3 ps seed pulses for a high-power CO2 laser amplifier that are multiple orders more energetic than seed pulses generated by slicing from a nanosecond CO2 laser pulse. We propose to send a 1 µm picosecond laser through a C6D6 Raman shifter and mix both the pump and shifted components in a DFG crystal to produce pulses at 10.6 µm. Preliminary results of a proof-of-principle experiment are presented.
Lee, Gi Soo; Irace, Alexandra; Rahbar, Reza
2017-06-01
To report the use of flexible fiber CO2 laser in the endoscopic management of pediatric airway cases. A retrospective review was conducted of patients who underwent CO2 laser-assisted airway procedures between September 2007 and January 2014 at a tertiary pediatric hospital. Sixty-eight patients underwent 80 procedures utilizing flexible fiber CO2 laser. Procedures included supraglottoplasty (n = 32), laryngeal cleft repair (type I [n = 10], type II [n = 7], type III [n = 6]), suprastomal granuloma excision (n = 6), cordotomy (n = 4), laryngeal neurofibroma excision (n = 4), laryngeal granulomatous mass excision (n = 1), subglottic stenosis excision (n = 6), division of glottic web (n = 2), subglottic cyst excision (n = 1), and supraglottic biopsy (n = 1). Ages ranged from 8 days to 21 years (median 11 months). No intraoperative or postoperative complications related to the use of laser were noted. The flexible fiber CO2 laser can be safely and effectively used to address a variety of pediatric airway lesions. Previously, the use of CO2 laser in minimally invasive airway surgery has been limited due to the articulating arm carrier, absence of a hand piece, and the direct line-of sight view required. The fiber allows the cutting beam to be directed at the site of the lesion and bypasses limitations posed by other laser systems. Copyright © 2017 Elsevier B.V. All rights reserved.
High-powered CO2 -lasers and noise control
NASA Astrophysics Data System (ADS)
Honkasalo, Antero; Kuronen, Juhani
High-power CO2 -lasers are being more and more widely used for welding, drilling and cutting in machine shops. In the near future, different kinds of surface treatments will also become routine practice with laser units. The industries benefitting most from high power lasers will be: the automotive industry, shipbuilding, the offshore industry, the aerospace industry, the nuclear and the chemical processing industries. Metal processing lasers are interesting from the point of view of noise control because the working tool is a laser beam. It is reasonable to suppose that the use of such laser beams will lead to lower noise levels than those connected with traditional metal processing methods and equipment. In the following presentation, the noise levels and possible noise-control problems attached to the use of high-powered CO2 -lasers are studied.
Laser myringotomy with the CO2 Otoscan laser
NASA Astrophysics Data System (ADS)
Sedlmaier, Benedikt W.; Jivanjee, Antonio; Schoenfeld, Uwe; Jovanovic, Sergije
2000-06-01
Tympanic ventilation is the treatment of choice for otitis media with effusion (OME). CO2 laser myringotomy has already proven its value and is finding increasing clinical application. The ventilation time in the middle ear is essentially determined by the size of the laser perforation. Perforations exceeding 2 mm in diameter enable tympanic ventilation for about three weeks and thus compete with the ventilation tube in the treatment of OME. IN a prospective study, laser myringotomy is performed in 84 children with OME with the new CO2 laser otoscope Otoscan. The closure time was 17 days in average for a preformation diameter of 2 mm. In the further clinical course, the ear-drums healed without atrophic scar formation. In an observation period of six month the recurrency rate of effusion was approximately 10 percent. Laser myringotomy seems to be an useful method in the operative therapy of secretory otitis media.
Atmospheric transmission of CO2 laser radiation with application to laser Doppler systems
NASA Technical Reports Server (NTRS)
Murty, S. S. R.
1975-01-01
The molecular absorption coefficients of carbon dioxide, water vapor, and nitrous oxide are calculated at the P16, P18, P20, P22, and P24 lines of the CO2 laser for temperatures from 200 to 300 K and for pressures from 100 to 1100 mb. The temperature variation of the continuum absorption coefficient of water vapor is taken into account semi-empirically from Burch's data. The total absorption coefficient from the present calculations falls within + or - 20 percent of the results of McClatchey and Selby. The transmission loss which the CO2 pulsed laser Doppler system experiences was calculated for flight test conditions for the five P-lines. The total transmission loss is approximately 7 percent higher at the P16 line and 10 percent lower at the P24 line compared to the P20 line. Comparison of the CO2 laser with HF and DF laser transmission reveals the P2(8) line at 3.8 micrometers of the DF laser is much better from the transmission point of view for altitudes below 10 km.
Nonlinear optical properties of Nd3+-Li+ co-doped ZnS-PVP thin films
NASA Astrophysics Data System (ADS)
Talwatkar, S. S.; Sunatkari, A. L.; Tamgadge, Y. S.; Muley, G. G.
2018-04-01
The nonlinear optical properties of Nd3+-Li+ co-doped ZnS-PVP nanocomposite were studied using a continuous wave (CW) He-Ne laser (λ = 632.8 nm)by z-scan technique. The nonlinear refractive index (n2), absorption coefficient (β) and third order nonlinear susceptibility (χ(3)) of PVP thin films embedded with Nd3+-Li+ co-doped ZnS NPs was found in the order of 10-7 cm2/W, 10-6 cm/W and 10-7 esu respectively. The nonlinearity found increasing with Nd3+-Li+ co-dopant concentration. Based on the results, it is proposed that this material is a new class of luminescent material suitable in optoelectronics devices application, especially in light-emitting devices, electroluminescent devices, display devices, etc.
[Experimental investigation of laser plasma soft X-ray source with gas target].
Ni, Qi-liang; Gong, Yan; Lin, Jing-quan; Chen, Bo; Cao, Jian-lin
2003-02-01
This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free. And it has higher operating frequency than gas target soft X-ray sources whose nozzle is controlled by a solenoid valve. A channel electron multiplier (CEM) operating in analog mode is used to detect the soft X-ray generated by the laser plasma source, and the CEM's output is fed to to a charge-sensitive preamplifier for further amplification purpose. Output charges from the CEM are proportional to the amplitude of the preamplifier's output voltage. Spectra of CO2, Xe and Kr at 8-14 nm wavelength which can be used for soft X-ray projection lithography are measured. The spectrum for CO2 consists of separate spectral lines originate mainly from the transitions in Li-like and Be-like ions. The Xe spectrum originating mainly from 4d-5f, 4d-4f, 4d-6p and 4d-5p transitions in multiply charged xenon ions. The spectrum for Kr consists of separate spectral lines and continuous broad spectra originating mainly from the transitions in Cu-, Ni-, Co- and Fe-like ions.
NASA Astrophysics Data System (ADS)
Hawkins, Jan F.; McCauley, Charles T.
2005-04-01
The purpose of this study was to evaluate the outcome of horses treated for cutaneous masses with the carbon dioxide (CO2) laser. The records of 65 horses were examined. Surgery was performed under general anesthesia or standing under sedation and local anesthesia. Excision was performed freehand using a focused beam with power settings ranging from 10 to 32 Watts in a continuous mode. Following en bloc removal of masses the subcutaneous tissue and wound margins were photovaporized using a defocused beam. Follow-up information was obtained via telephone interview with owners or referring veterinarians Cutaneous masses were divided into three groups: sarcoid (29), neoplasia including squamous cell carcinoma (15), melanoma (6), schwanoma (2), fibroma (1), and fibrosarcoma (1), and non-neoplastic masses (11). Mass reoccurrence developed in 8 of 29 (28%) sarcoids and 4 of 14 (29%) squamous cell carcinoma. No reoccurrence was reported for horses diagnosed with melanoma, schwanoma, fibrosarcoma, fibroma, or any of the non-neoplastic masses. Sixty of 63 owners (95%) reported that they were satisfied with the outcome of the procedure. This study demonstrates that the CO2 laser is an effective means of treating cutaneous masses in horses.
Clinical applications of CO2 laser resurfacing in the treatment of various pathologic skin disorders
NASA Astrophysics Data System (ADS)
Giler, Shamai
1997-12-01
CO2 laser skin resurfacing devices are widely used in cosmetic surgery for the treatment of facial rhytides, acne scars and aging skin. This technique is also useful in the treatment of various benign and premalignant or multiple pathological skin conditions and disorders originating in the epidermal, dermal and skin appendages, vascular lesions, epidermal nevi, infected wounds and ulcers, and keloids. Various surgical techniques have been developed in our clinic using laser resurfacing in the treatment of more than 2,000 patients with various skin pathologic disorders. We describe our experience with the various techniques used. The precise depth control and ablation properties combined with the hemostatic and sterilizing effects of the CO2 laser beam, reduction of the possibility of bleeding, infection and damage to healthy tissues, make the CO2 laser resurfacing techniques the treatment of choice for cosmetic surgery and treatment of benign, premalignant and multiple pathologic skin conditions.
Błochowiak, Katarzyna; Andrysiak, Piotr; Sidorowicz, Krzysztof; Witmanowski, Henryk; Hędzelek, Wiesław; Sokalski, Jerzy
2015-10-01
Benign neoplasms and hyperplastic tumorous lesions are common oral pathologies. These lesions require to be surgically removed by conventional surgery, laser, or electrosurgery. Surgical treatment aims at complete removal of pathological lesions and ensuring proper healing of the tissues to minimize the risk of lesion recurrence. To present possible applications of Er:YAG and CO2 lasers in removal of benign neoplasms and tumorous lesions developing on oral mucosa as well as to specify indications and limitations of these two methods. Temperature-induced injuries due to laser light application, possibility of post-operative histopathological evaluation of the removed tissue, efficacy of the cut and coagulation, healing process and completeness of laser surgeries give rise to our special concern. The main asset of the CO2 laser comparing to Er:YAG laser is an effective coagulation while thermal injury to the tissues is its limitation, especially with multiple passage of the beam and too high power applied. Er:YAG laser application does not exclude histopathological examination of the removed lesion tissue which is its advantage over CO2 laser. Still, insufficient coagulation is a limitation ofits use in the case of richly vascularized lesions.
Detection of NO sub x,C2H4 concentrations by using CO and CO2 lasers
NASA Technical Reports Server (NTRS)
Gengchen, W.; Qinxin, K.
1986-01-01
A laser, especially the infrared line tunable laser, opens up a new way to monitor the atmospheric environment, and already has gotten effective practical application. One of the most serious problems in open path remote measurement at atmospheric pressure is the broadening effect which leads to increased linewidths, spectral interferences, and, as a result, tends to reduce detection sensitivity, so measuring laser wavelengths should be selected carefully, and interaction between the measuring wavelength and gas to be measured must be known very well. Therefore, N2O, No, NO2, CH4, NH3 and C2H4 absorption properties at some lines of CO and CO2 line tunable lasers were studied. The absorption coefficients of NO, NO2, and C2H4; some results on detection of NO sub x, C2H4 concentrations in both laboratory and field; and selection of measuring wavelengths and error analysis are discussed.
NASA Astrophysics Data System (ADS)
Chan, Chi-Wai; Carson, Louise; Smith, Graham C.; Morelli, Alessio; Lee, Seunghwan
2017-05-01
Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.
Parameter optimization for selective laser melting of TiAl6V4 alloy by CO2 laser
NASA Astrophysics Data System (ADS)
Baitimerov, R. M.; Lykov, P. A.; Radionova, L. V.; Safonov, E. V.
2017-10-01
TiAl6V4 alloy is one of the widely used materials in powder bed fusion additive manufacturing technologies. In recent years selective laser melting (SLM) of TiAl6V4 alloy by fiber laser has been well studied, but SLM by CO2-lasers has not. SLM of TiAl6V4 powder by CO2-laser was studied in this paper. Nine 10×10×10 mm cubic specimens were fabricated using different SLM process parameters. All of the fabricated specimens have a good dense structure and a good surface finish quality without dimensional distortion. The lowest porosity that was achieved was about 0.5%.
Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.
Sosis, M B; Dillon, F X
1991-02-01
To determine whether the filling of tracheal tube cuffs with saline would decrease their combustibility during laser surgery, 20 polyvinylchloride tracheal tubes were studied. The cuffed end of each tracheal tube was inserted into the neck of an empty flask, and the tube and flask were flushed with oxygen for 5 min before cuff inflation. Ten tracheal tubes had their cuffs inflated with air, and 10 were inflated with saline. A Lasersonics LS880 CO2 laser, set to 5 W for five of each of the two types of filled cuffs and to 40 W for the other pair of five tubes, was fired continuously at the cuffs for up to 1 min. No combustion occurred at the 5-W setting. The times to cuff perforation when the laser was set at 5 W were (mean +/- SD) 1.00 +/- 0.83 and 4.21 +/- 3.91 s for the air- and saline-filled cuffs, respectively, a difference that was not statistically significant. The time to deflation of the saline-filled cuff (104.6 +/- 67.5 s) was, however, significantly longer than that of the air-filled cuff (2.59 +/- 1.97 s). When the tracheal tube cuffs were exposed to 40-W laser radiation, the cuff and adjacent tube shaft ignited in all cases when the cuffs were inflated with air, but only in one of five cases when the cuffs were filled with saline (P less than 0.05). The filling of tracheal tube cuffs with saline provides simple, moderately effective partial protection of the cuff of endotracheal tubes during CO2 laser airway surgery.
Monte-Carlo based Uncertainty Analysis For CO2 Laser Microchanneling Model
NASA Astrophysics Data System (ADS)
Prakash, Shashi; Kumar, Nitish; Kumar, Subrata
2016-09-01
CO2 laser microchanneling has emerged as a potential technique for the fabrication of microfluidic devices on PMMA (Poly-methyl-meth-acrylate). PMMA directly vaporizes when subjected to high intensity focused CO2 laser beam. This process results in clean cut and acceptable surface finish on microchannel walls. Overall, CO2 laser microchanneling process is cost effective and easy to implement. While fabricating microchannels on PMMA using a CO2 laser, the maximum depth of the fabricated microchannel is the key feature. There are few analytical models available to predict the maximum depth of the microchannels and cut channel profile on PMMA substrate using a CO2 laser. These models depend upon the values of thermophysical properties of PMMA and laser beam parameters. There are a number of variants of transparent PMMA available in the market with different values of thermophysical properties. Therefore, for applying such analytical models, the values of these thermophysical properties are required to be known exactly. Although, the values of laser beam parameters are readily available, extensive experiments are required to be conducted to determine the value of thermophysical properties of PMMA. The unavailability of exact values of these property parameters restrict the proper control over the microchannel dimension for given power and scanning speed of the laser beam. In order to have dimensional control over the maximum depth of fabricated microchannels, it is necessary to have an idea of uncertainty associated with the predicted microchannel depth. In this research work, the uncertainty associated with the maximum depth dimension has been determined using Monte Carlo method (MCM). The propagation of uncertainty with different power and scanning speed has been predicted. The relative impact of each thermophysical property has been determined using sensitivity analysis.
[The use of lasers in dermatology].
Lecocq, C; Pirard, D; del Marmol, V; Berlingin, E
2013-01-01
Albert Einstein is undoubtedly the father of lasers. But it is not until 1964 that the first dermatological lasers were introduced. The Nd-YAG laser, the CO2 laser were developed by Kumar Patel. In a 40 year period lasers not only were diversified but have also become safer and miniaturized. This article hopes to strengthen general practionners' and specialist's knowledge of the different categories of available lasers. The most frequently used ones are ablative lasers (CO2-Erbium), vascular lasers (Nd-YAG, KTP, pulsed dye laser) and the pigment lasers (Q-Switched Nd-YAG, Alexandrite). A description of these lasers and their indications in dermatology will be discussed.
NASA Technical Reports Server (NTRS)
Chen, W.; Mouret, G.; Boucher, D.; Tittel, F. K.
2001-01-01
A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of 12 cm-1 and a temperature tuning rate of 1.02 cm-1/degree C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described.
Lepri, Taísa Penazzo; Colucci, Vivian; Turssi, Cecília Pedroso; Corona, Silmara Aparecida Milori
2015-06-01
Interest in erosion and its role in tooth wear has increased considerably. Due to the limited contribution of patients in modifying their dietary habits, therapeutic resources aiming to reduce the progression of erosion-like lesions have been discussed. This study sought to evaluate the effect of TiF4 and CO2 laser in controlling the permeability of in situ eroded enamel. Ten volunteers wore an intraoral palatal device containing two enamel slabs, treated with TiF4 gel and TiF4 gel + CO2 or placebo gel and placebo gel + CO2. After the washout period, volunteers were crossed over to the other treatment. During both phases, specimens were submitted to erosive challenges and then evaluated for permeability measured as the percentage of copper ion penetration over the total enamel thickness. Two-way analysis of variance (ANOVA) revealed that there was a significant interaction between the factors under study (p = 0.0002). Tukey's test showed that TiF4 significantly reduced the enamel permeability of eroded enamel specimens, regardless of whether CO2 laser irradiation was performed. It may be concluded that when the placebo gel was applied, CO2 laser was able to reduce enamel permeability; however, when TiF4 was applied, laser irradiation did not imply a reduction in permeability. TiF4 provided a lower permeability of eroded enamel, regardless of whether the CO2 laser was used. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Abdel-Kader, Mahmoud H.; El-Nozahy, Adel M.; Ahmed, Salwa M. S.; Khalifa, Ibtesam A.
2007-02-01
The present work was carried out to evaluate the actual effect of subleathal dosage of LD30 of two different lasers (Argon-ion and CO2 lasers) on the main metabolites, phosphatases enzymes, transaminases, acetylcholinestrase and peroxidases in the one day adult stage of Trogoderma granarium treated as 2-3 days old pupae. Our results clearly indicated that two different wavelengths of laser radiation increased significantly the total proteins content, whereas no significant changes occurred in the total lipids for the two laser radiation wavelenghts. On the other hand the total carbohydrates were significantly decreased when irradiating using CO2 laser wavelength which is not the case for the Argon-ion laser radiation. Significant changes of phosphatases occurred for both wavelengths. Inhibition of transaminases GOT (glutamic oxaloacetic transaminases) and insignificant changes of GPT (glutamic pyruvic oxaloacetic transaminases) was observed for both laser wavelengths. Significant inhibition of acetyl cholinestrase was observed using CO2 laser and insignificant changes were recorded for Argon ion laser radiation where as insignificant decrease of peroxideses was observed for both lasers.
Mathew, Anju; Reddy, N. Venugopal; Sugumaran, D. K.; Peter, Joby; Shameer, M.; Dauravu, Liju Marcely
2013-01-01
Background: Dental caries is essentially a process of diffusion and dissolution. If the aspect of dissolution can be curtailed some degree of prevention can be achieved. Aims: The present study was carried out to evaluate and compare the effect of Er:YAG laser and Co2 laser irradiation combined with acidulated phosphate fluoride treatment on in vitro acid resistance of human enamel. Design: An in vitro study was carried out on 30 human premolars to evaluate the enamel's acid resistance using an atomic emission spectrometry analysis. Materials and Methods: A total of 60 enamel specimens were prepared from 30 human premolars and were randomly assigned to 6 groups: (1) Untreated (control); (2) 1.23% acidulated phosphate fluoride (APF) gel application alone for 4 min; (3) Er:YAG laser treatment alone; (4) Co2 laser treatment alone; (5) Er:YAG laser + APF gel application; (6) Co2 laser + APF gel application. The specimens were then individually immersed in 5 ml of acetate buffer solution (0.1 mol/L, pH 4.5) and incubated at 37°C for 24 h, and the acid resistance was evaluated by determining the calcium ion concentration using the atomic emission spectrometry. Statistical Analysis: An ANOVA model was constructed (P value of 0.05), followed by Tukey's test for multiple pair wise comparisons of mean values. Results: Significant differences were found between the control group and the test groups (P < 0.001). Conclusions: Combining acidulated phosphate fluoride with either Er:YAG or Co2 laser had a synergistic effect in decreasing the enamel demineralization more than either fluoride treatment or laser treatment alone. PMID:24015004
NASA Astrophysics Data System (ADS)
Spearrin, R. M.; Goldenstein, C. S.; Schultz, I. A.; Jeffries, J. B.; Hanson, R. K.
2014-07-01
A mid-infrared laser absorption sensor was developed for gas temperature and carbon oxide (CO, CO2) concentrations in high-enthalpy, hydrocarbon combustion flows. This diagnostic enables non-intrusive, in situ measurements in harsh environments produced by hypersonic propulsion ground test facilities. The sensing system utilizes tunable quantum cascade lasers capable of probing the fundamental mid-infrared absorption bands of CO and CO2 in the 4-5 µm wavelength domain. A scanned-wavelength direct absorption technique was employed with two lasers, one dedicated to each species, free-space fiber-coupled using a bifurcated hollow-core fiber for remote light delivery on a single line of sight. Scanned-wavelength modulation spectroscopy with second-harmonic detection was utilized to extend the dynamic range of the CO measurement. The diagnostic was field-tested on a direct-connect scramjet combustor for ethylene-air combustion. Simultaneous, laser-based measurements of carbon monoxide and carbon dioxide provide a basis for evaluating combustion completion or efficiency with temporal and spatial resolution in practical hydrocarbon-fueled engines.
Robati, Reza M; Asadi, Elmira
2017-02-01
Ablative fractional lasers were introduced for treating facial rhytides. Few studies have compared fractional CO 2 and Er:YAG lasers on cutaneous photodamages by a split trial. The aim of the present study was to compare these modalities in a randomized controlled double-blind split-face design with multiple sessions and larger sample size compared to previous studies done before. Forty patients with facial wrinkles were enrolled. Patients were randomly assigned to receive three monthly treatments on each side of the face, one with a fractional CO 2 and one with a fractional Er:YAG laser. The evaluations included investigating clinical outcome determined by two independent dermatologists not enrolled in the treatment along with measuring skin biomechanical property of cheeks using a sensitive biometrologic device with the assessment of cutaneous resonance running time (CRRT). Moreover, possible side effects and patients' satisfaction have been recorded at baseline, 1 month after each treatment, and 3 months after the last treatment session. Clinical assessment showed both modalities significantly reduce facial wrinkles (p value < 0.05), with no appreciable difference between two lasers. Mean CRRT values also decreased significantly after the laser treatment compared to the baseline in both laser groups. There was no serious long-standing adverse effect after both laser treatments, but the discomfort was more pronounced by the participants after CO 2 laser treatment. According to the present study, both fractional CO 2 and fractional Er:YAG lasers show considerable clinical improvement of facial skin wrinkles with no serious adverse effects, but post-treatment discomfort seems to be lower with Er:YAG laser.
Thoracoscopic CO laser coagulation shrinkage of blebs in treatment of spontaneous pneumothorax
NASA Astrophysics Data System (ADS)
Sensaki, Koji; Arai, Tsunenori; Kikuchi, Keiichi; Takagi, Keigo; Tanaka, Susumu; Kikuchi, Makoto
1992-06-01
Spontaneous pneumothorax is a common disease in young people. Operative intervention has been done in most of the recurrent cases. Recently thoracoscopic treatment has been tested as a less invasive treatment modarity. We adopted carbon monoxide (CO) laser for thoracoscopic treatment of recurrent spontaneous pneumothorax. CO laser (wavelength; 5.4 micrometers ) could be delivered by chalcogenide glass (As - S) covered with a teflon sheath and ZnSe fiber tip. The sterilized flexible bronchoscope was inserted through the thoracoscopic outer sheath under local anesthesia. Shrinkage of blebs was obtained by non-contact method of CO laser irradiation. Laser power at the tip was 2.5 - 5 W and irradiation duration was 0.5 s each. Excellent shrinkage of bleb and bulla could be obtained by CO laser without perforation complication. Advantages of CO laser as a thoracoscopic treatment were: (1) capability of fiber delivery (flexible thoracoscopy was easy to operate and clear to visualize the blebs which were frequently found at the apical portion of the lung, and (2) shallow extinction length (good shrinkage of blebs, low risk of perforation, and thin layer of carbonization). In conclusion, our new technique of thoracoscopic CO laser irradiation was found to be a safe and effective treatment of spontaneous pneumothorax.
Kraeva, Ekaterina; Ho, Derek; Jagdeo, Jared
2017-09-01
Keloids are fibrous growths that occur as a result of abnormal response to dermal injury. Keloids are cosmetically disfiguring and may impair function, often resulting in decreased patient quality-of-life. Treatment of keloids remains challenging, and rate of recurrence is high. We present a case of a 39-year-old African-American man (Fitzpatrick VI) with a 10-year history of keloid, who was successfully treated with eight sessions of fractionated carbon dioxide (CO2) laser immediately followed by laser-assisted drug delivery (LADD) of topical triamcinolone acetonide (TAC) ointment and review the medical literature on fractionated CO2 laser treatment of keloids. To the best of our knowledge, this is the first report of successful treatment of a keloid using combination therapy of fractionated CO2 laser and LADD with topical TAC ointment in an African-American man (Fitzpatrick VI) with excellent cosmetic results sustained at 22 months post-treatment. We believe that this combination treatment modality may be safe and efficacious for keloids in skin of color (Fitzpatrick IV-VI) and other patients. This case highlights the ability of laser surgeons to safely use fractionated CO2 lasers in patients of all skin colors.
J Drugs Dermatol. 2017;16(9):925-927.
.Laser versus cold instruments for microlaryngoscopic surgery.
Zeitels, S M
1996-05-01
Controversy has arisen concerning the merits of the CO2 laser in microlaryngoscopic surgery because of the potentially harmful effects that the injudicious application of the laser could have on voice production. In an effort to develop a logical approach to instrument selection, the author examined the use of both cold instruments and the CO2 laser in the treatment of various benign and malignant lesions. A retrospective review of 307 microlaryngeal procedures performed over a 3-year period revealed that 263 (86%) were glottal and 44 (14%) were supraglottal. Of the 263 glottal procedures, 203 (77%) employed cold instruments alone and 60 (23%) used both cold instruments and the CO2 laser. The laser was used to assist in all 44 supraglottal procedures. Therefore, 203 (66%) of 307 procedures were done with cold instruments alone, and 104 (34%) of 307 procedures were performed using the CO2 laser with cold instruments. Lesions were stratified on the basis of pathology and size, as well as surgical approach. A primary phonomicrosurgical principle in glottal surgery is to maximally preserve the vocal fold's layered microstructure (laminae propria and epithelium). Precise tangential dissection was necessary for achieving this goal. For limited lesions, this dissection was best accomplished with cold instruments alone. The CO2 laser facilitated hemostatic surgical dissection for all supraglottal lesions and for selected larger glottal lesions in which bleeding would obscure visualization of the microanatomy of the musculomembranous vocal fold.
Usefulness of the infrared heterodyne radiometer in remote sensing of atmospheric pollutants.
NASA Technical Reports Server (NTRS)
Menzies, R. T.; Shumate, M. S.
1971-01-01
The application of narrow-band optical receivers to the problem of sensing atmospheric pollution is discussed. The emission/absorption lines of many major atmospheric pollutant molecules overlap the operating frequency bands of CO2 laser and CO laser heterodyne receivers. Several remote pollution sensing systems which are based upon utilization of these spectral overlaps are described, and an analysis of their potential is presented. The possibility of using other lasers (e.g.: the PbSnTe tunable diode laser) as local oscillators is also considered. Results of laboratory experiments with a CO2 laser heterodyne radiometer are presented.
Constantin, Alina; Dumitrescu, Madalina; Mihai Corotchi, Maria Cristina; Jianu, Dana; Simionescu, Maya
2017-01-01
CO 2 laser has a beneficial effect on stem cells by mechanisms that are not clearly elucidated. We hypothesize that the effect of fractional CO 2 laser on human adipose-derived stem cells (ADSC) could be due to changes in redox homeostasis and secretion of factors contributing to cellular proliferation and angiogenic potential. ADSC incubated in medium containing 0.5 or 10 % FBS were exposed to a single irradiation of a 10,600-nm fractional CO 2 laser; non-irradiated ADSC were used as control. Viability/proliferation of ADSC was assessed by MTT assay; the intracellular reactive oxygen species (ROS) levels and the mitochondrial membrane potential (∆Ψ m ) were determined with DCFH-DA and JC-1 fluorescent probes, respectively. Molecules secreted by ADSC in the medium were determined by ELISA assay, and their capacity to support endothelial tube-like formation by the Matrigel assay. The results showed that compared to controls, ADSC kept in low FBS medium and irradiated with CO 2 laser at 9 W exhibited: (a) increased proliferation (∼20 %), (b) transient increase of mitochondrial ROS and the capacity to restore Δψ m after rotenone induced depolarization, and (c) augmented secretion in the conditioned medium of MMP-2 (twofold), MMP-9 (eightfold), VEGF (twofold), and adiponectin (∼50 %) that have the capacity to support angiogenesis of endothelial progenitor cells. In conclusion, the mechanisms underlying the benefic effect of CO 2 laser on ADSC are the activation of the redox pathways which increases cell proliferation and enhances secretion of angiogenic molecules. These results explain, in part, the mechanisms involved in the increased regenerative potential of CO 2 laser-exposed ADSC that could be exploited for clinical applications.
Treatment of striae distensae with needling therapy versus CO2 fractional laser.
Khater, Mohamed H; Khattab, Fathia M; Abdelhaleem, Manal R
2016-01-01
Striae are atrophic dermal scars with overlying epidermal atrophy causing cosmetic concern. This study assesses and compares the efficacy and safety of needling therapy versus CO2 fractional laser in treatment of striae. Twenty Egyptian female patients with striae in the abdomen and lower limbs were involved in the study. The patients were treated with needling therapy and CO2 laser every 1 month for 3 sessions. Follow-up by digital photography and skin biopsy was conducted at baseline and 6 months after treatment. Clinical improvement was assessed by comparing photographs and patient's satisfaction before and after treatment. Nine of 10 (90%) needle-treated patients showed improvement. Among them, 3 (30%) had good, 4 (40%) had fair, and 2 (20%) had poor improvements; however, 1 (10%) did not show any improvement after the treatment. In CO2-laser treated patients, 5 of 10 (50%) of the patients showed clinical improvement; 1 (10%) were good, 3 (30%) were fair, and 1 (10%) were poor; however, 5 (50%) did not show improvement. The results support the use of microneedle therapy over CO2 lasers for striae treatment.
Lévesque, Luc; Noël, Jean-Marc; Scott, Calum
2015-12-01
Temperature of porcine bone specimens are investigated by aiming a pulsed CO2 laser beam at the bone-air surface. This method of controlling temperature is believed to be flexible in medical applications as it avoids the uses of thermal devices, which are often cumbersome and generate rather larger temperature variations with time. The control of temperature using this method is modeled by the heat-conduction equation. In this investigation, it is assumed that the energy delivered by the CO2 laser is confined within a very thin surface layer of roughly 9 μm. It is shown that temperature can be maintained at a steady temperature using a CO2 laser and we demonstrate that the method can be adapted to be used in tandem with another laser beam. This method to control the temperature is believed to be useful in de-contamination of bone during the implantation treatment, in bone augmentation when using natural or synthetic materials and in low-level laser therapy.
"One-shot" CO2 versus Er:YAG laser stapedotomy: is the outcome the same?
Marchese, Maria Raffaella; Scorpecci, Alessandro; Cianfrone, Francesca; Paludetti, Gaetano
2011-03-01
To assess and compare the functional results obtained by means of multiple-shot Erbium: yttrium-aluminum-garnet (Er:YAG) laser to those obtained using "one-shot" CO(2) laser stapedotomy in patients affected by otosclerosis. A retrospective case review was performed. Of the total number of 123 patients (114 ears) who underwent primary small-fenestra stapedotomy from January 2006 to September 2008, seven patients who received multiple-shot laser CO(2) stapedotomy were excluded from the study. The remaining 116 patients (104 ears) were sorted, and "one-shot" CO(2) laser stapedotomy (group A) was performed in 35/104 and Er:YAG laser stapedotomy (group B) in 69/104. After surgery, air conduction-pure tone average (AC-PTA) and air-bone gap (ABG) improved significantly in both groups, whereas sensorineural hearing loss (SNHL) and bone conduction (BC)-PTA did not change in both the groups. In group A, the postoperative ABG was significantly better (12.63 vs. 14.86 dB). Moreover, after "one-shot" stapedotomy, the AC-PTA significantly improved in all tested frequencies. On the contrary, in group B the AC-PTA improved significantly only in two frequencies (0.5 and 1 kHz). Consistent with previous reports, our findings confirm that laser stapedotomy is a safe and effective surgery, regardless of the technique. Based on our functional results, the "one-shot" CO(2) laser technique seems to be associated with a significantly better postoperative ABG if compared to Er:YAG laser stapedotomy.
Early effect of fractional CO2 laser treatment in Post-menopausal women with vaginal atrophy.
Eder, Scott Evan
2018-03-31
Fractional CO 2 lasers have been shown to provide improvement of vulvovaginal atrophy (VVA). The aim of the current study was to assess the early effect of a fractional CO 2 laser system in treating postmenopausal women with clinical symptoms of VVA. 28 healthy post-menopausal women (mean age 60.1 ± 5.55 years) with VVA-related symptoms were treated with fractional CO 2 laser 3 times, in 4-week intervals. At each study visit, VHIS score and VVA symptom severity were recorded. Sexual function was assessed with the Female Sexual Function Index (FSFI). One month following the first laser treatment, the mean VHIS score was significantly improved (13.89 ± 4.25 vs. baseline 11.93 ± 3.82; p < 0.05), and improved further at 3 and 6 months following all three laser treatments (16.43 ± 4.20 and 17.46 ± 4.07, respectively). Almost all VVA symptoms were significantly improved at one month following the first treatment. A further significant improvement in VVA symptoms was noted at 3 and 6 months following the third laser treatment. Following treatments, the FSFI score increased significantly (22.36 ± 10.40 vs. baseline 13.78 ± 7.70; p < 0.05), and remained significantly higher than baseline at the 3- and 6-month follow-up visits. CO 2 laser therapy for post-menopausal women can be considered an effective therapeutic option providing relief of symptoms already noted after one laser treatment.
The use of pulsed CO2 lasers for the treatment of vulvovaginal atrophy.
Salvatore, Stefano; Athanasiou, Stavros; Candiani, Massimo
2015-12-01
This article reviews the literature regarding the safety and efficacy of the use of a pulsed CO2 laser for the treatment of vulvovaginal atrophy (VVA). Prospective observational studies have demonstrated histological changes after the use of pulsed CO2 laser vaginally in atrophic conditions. Increased collagen and extracellular matrix production has been reported together with an increase in the thickness of the vaginal epithelium with the formation of new papilla. Three different observational studies reported a significant improvement of VVA assessed subjectively (with a 10-point visual analogue scale) and objectively (using the Vaginal Health Index) after a cycle of three treatments of pulsed CO2 laser. Also sexual function (assessed with the Female Sexual Function Index) and quality of life (evaluated with the SF12 questionnaire) significantly improved. No complications or side-effects were reported during or after the laser procedure that was performed in an outpatient setting. Increasing evidence with histological and clinical data supports the use of pulsed CO2 lasers in the treatment of VVA; however, no randomized control trial (sham versus treatment) has yet been produced and no data on the duration of therapy are currently available.
Stereotactic CO2 laser therapy for hydrocephalus
NASA Astrophysics Data System (ADS)
Kozodoy-Pins, Rebecca L.; Harrington, James A.; Zazanis, George A.; Nosko, Michael G.; Lehman, Richard M.
1994-05-01
A new fiber-optic delivery system for CO2 radiation has been used to successfully treat non-communicating hydrocephalus. This system consists of a hollow sapphire waveguide employed in the lumen of a stereotactically-guided neuroendoscope. CO2 gas flows through the bore of the hollow waveguide, creating a path for the laser beam through the cerebrospinal fluid (CSF). This delivery system has the advantages of both visualization and guided CO2 laser radiation without the same 4.3 mm diameter scope. Several patients with hydrocephalus were treated with this new system. The laser was used to create a passage in the floor of the ventricle to allow the flow of CSF from the ventricles to the sub-arachnoid space. Initial postoperative results demonstrated a relief of the clinical symptoms. Long-term results will indicate if this type of therapy will be superior to the use of implanted silicone shunts. Since CO2 laser radiation at 10.6 micrometers is strongly absorbed by the water in tissue and CSF, damage to tissue surrounding the lesion with each laser pulse is limited. The accuracy and safety of this technique may prove it to be an advantageous therapy for obstructive hydrocephalus.
NASA Technical Reports Server (NTRS)
Sokoloski, Martin M. (Editor)
1989-01-01
Various papers on laser applications in meteorology and earth and atmospheric remote sensing are presented. The individual topics addressed include: solid state lasers for the mid-IR region, tunable chromium lasers, GaInAsSb/AlGaAsSb injection lasers for remote sensing applications, development and design of an airborne autonomous wavemeter for laser tuning, fabrication of lightweight Si/SiC lidar mirrors, low-cost double heterostructure and quantum-well laser array development, nonlinear optical processes for the mid-IR region, simulated space-based Doppler lidar performance in regions of backscatter inhomogeneities, design of CO2 recombination catalysts for closed-cycle CO2 lasers, density measurements with combined Raman-Rayleigh lidar, geodynamics applications of spaceborne laser ranging, use of aircraft laser ranging data for forest mensuration, remote active spectrometer, multiwavelngth and triple CO2 lidars for trace gas detection, analysis of laser diagnostics in plumes, laser atmospheric wind sounder, compact Doppler lidar system using commercial off-the-shelf components, and preliminary design for a laser atmospheric wind sounder.
Nowak, Krzysztof M; Ohta, Takeshi; Suganuma, Takashi; Yokotsuka, Toshio; Fujimoto, Junichi; Mizoguchi, Hakaru; Endo, Akira
2012-11-15
In this Letter, we investigate, for the first time to our knowledge, the spectral properties of a quantum-cascade laser (QCL) from a point of view of a new application as a laser seeder for a nanosecond-pulse high-repetition frequency CO(2) laser operating at 10.6 μm wavelength. The motivation for this work is a renewed interest in such a pulse format and wavelength driven by a development of extreme UV (EUV) laser-produced-plasma (LPP) sources. These sources use pulsed multikilowatt CO(2) lasers to drive the EUV-emitting plasmas. Basic spectral performance characteristics of a custom-made QCL chip are measured, such as tuning range and chirp rate. The QCL is shown to have all essential qualities of a robust seed source for a high-repetition nanosecond-pulsed CO(2) laser required by EUV LPP sources.
Laser discrimination by stimulated emission of a phosphor
NASA Technical Reports Server (NTRS)
Mathur, V. K.; Chakrabarti, K.
1991-01-01
A method for discriminating sources of UV, near infrared, and far infrared laser radiation was discovered. This technology is based on the use of a single magnesium sulfide phosphor doubly doped with rare earth ions, which is thermally/optically stimulated to generate colors correlatable to the incident laser radiation. The phosphor, after initial charging by visible light, exhibits green stimulated luminescence when exposed to a near infrared source (Nd: YAG laser). On exposure to far infrared sources (CO2 laser) the phosphor emission changes to orange color. A UV laser produces both an orange red as well as green color. A device using this phosphor is useful for detecting the laser and for discriminating between the near infrared, far infrared, and UV lasers. The technology is also capable of infrared laser diode beam profiling since the radiation source leaves an imprint on the phosphor that can be photographed. Continued development of the technology offers potential for discrimination between even smaller bandwidths within the infrared spectrum, a possible aid to communication or wavemixing devices that need to rapidly identify and process optical signals.
Du, Feiya; Yu, Yusheng; Zhou, Zhiqin; Wang, Liujia; Zheng, Shusen
2018-04-01
Fractional CO 2 laser is one of the most effective treatment options used to resurface scars. However, most previous studies have been performed on mature scars at least 2 months after surgery. Recent studies have emphasized the importance of early treatment to reduce scar formation. In the present study, we described our experience with fractional CO 2 laser intervention before skin suture during scar revision surgery in Asians, and found the treatment was safe and effective.
Laser arthroscopic surgery of the shoulder and knee
NASA Astrophysics Data System (ADS)
Smith, Chadwick F.; Johansen, Ed; Bonvalet, Todd; Sutter, Leroy V., Jr.; Marshall, G. June
1990-06-01
The laser is used less in orthopaedics than in any other medical specialty. Improving technology and the impressive effect of the CO2 laser on orthopaedic tissues has, however, accelerated the interest of orthopaedic surgeons over the past two years. The carbon dioxide laser is now commonly used in orthopaedics for difficult to access lesions of the knee - particularly those of a degenerative nature with high surface area and low volume. The results are presented in this paper and reveal no evidence of lasting complications. Although several types of lasers are being experimentally utilized in orthopaedics, the YAG and CO2 lasers are the only lasers commonly utilized. The YAG laser is utilized for shoulder arthroscopy and offers the advantage of passage of energy through fiber and the ability to utilize the tool in an aqueous environment. It is too early to determine as to whether or not the YAG laser or the CO2 laser will be the most efficient energy delivery system for use in the shoulder.
Residual stress and damage-induced critical fracture on CO2 laser treated fused silica
NASA Astrophysics Data System (ADS)
Matthews, M. J.; Stolken, J. S.; Vignes, R. M.; Norton, M. A.; Yang, S.; Cooke, J. D.; Guss, G. M.; Adams, J. J.
2009-10-01
Localized damage repair and polishing of silica-based optics using mid- and far-IR CO2 lasers has been shown to be an effective method for increasing optical damage threshold in the UV. However, it is known that CO2 laser heating of silicate surfaces can lead to a level of residual stress capable of causing critical fracture either during or after laser treatment. Sufficient control of the surface temperature as a function of time and position is therefore required to limit this residual stress to an acceptable level to avoid critical fracture. In this work we present the results of 351 nm, 3ns Gaussian damage growth experiments within regions of varying residual stress caused by prior CO2 laser exposures. Thermally stressed regions were non-destructively characterized using polarimetry and confocal Raman microscopy to measure the stress induced birefringence and fictive temperature respectively. For 1~40s square pulse CO2 laser exposures created over 0.5-1.25kW/cm2 with a 1-3mm 1/e2 diameter beam (Tmax~1500-3000K), the critical damage site size leading to fracture increases weakly with peak temperature, but shows a stronger dependence on cooling rate, as predicted by finite element hydrodynamics simulations. Confocal micro-Raman was used to probe structural changes to the glass over different thermal histories and indicated a maximum fictive temperature of 1900K for Tmax>=2000K. The effect of cooling rate on fictive temperature caused by CO2 laser heating are consistent with finite element calculations based on a Tool-Narayanaswamy relaxation model.
Impact of CO2 laser and stannous fluoride on primary tooth erosion.
Rocha, Cristiane Tomaz; Turssi, Cecilia Pedroso; Rodrigues-Júnior, Antonio Luiz; Corona, Silmara Aparecida Milori
2016-04-01
This study evaluated in vitro the effect of input power of CO2 laser, either associated or not to stannous fluoride (SnF2) gel, for the control of intrinsic erosion in primary teeth. One hundred four enamel slabs (3 × 3 × 2 mm) from human primary molars were flattened and polished. Adhesive tapes were placed on their surface leaving a window of 3 × 1 mm. Slabs were then cycled four times in 0.01 M hydrochloric acid (pH 2, 2 min) and in artificial saliva (2 h) for creation of erosive lesions. Specimens were randomly assigned into eight groups (n = 13) according to fluoride application [absent (control) or 0.4% stannous fluoride gel (SnF2)] and input power of CO2 laser [unlased (control), 0.5, 1.0 or 1.5 W]. The CO2 laser irradiation was performed in an ultra-pulse mode (100 μs of pulse duration), 4-mm working distance, for 10 s. Specimens were then submitted to further erosive episodes for 5 days and evaluated for enamel relative permeability. Fluoride did not show any protective effect for any of the laser-treated groups or control (p = 0.185). However, a significant effect was detected for input power of CO2 laser (p = 0.037). Tukey's test showed that there was a significant statistically difference between specimens irradiated with 0.5 and 1.5 W (p = 0.028). The input power of 0.5 W showed lower permeability. Variation of input power CO2 laser can influence enamel permeability, at the power of 1.5 W which promoted greater permeability.
Design and development of equipment for laser wire stripping
NASA Technical Reports Server (NTRS)
Iceland, W. F.
1977-01-01
Three laser wire strippers have been built for the stripping of Kapton-insulated wire, the baseline wire of the space shuttle orbiter. The strippers are: (1) a bench-model stripper powered with a cw CO2 10.6-micron laser, (2) a hand-held stripper powered with a cw 1.06-micron Nd-YAG laser with an output of 5-7 watts, and (3) a hand-held stripper with a five-inch-long CO2 laser inside the stripping head.
Spectroscopic detection of biological NO with a quantum cascade laser
NASA Technical Reports Server (NTRS)
Menzel, L.; Kosterev, A. A.; Curl, R. F.; Tittel, F. K.; Gmachl, C.; Capasso, F.; Sivco, D. L.; Baillargeon, J. N.; Hutchinson, A. L.; Cho, A. Y.;
2001-01-01
Two configurations of a continuous wave quantum cascade distributed feedback laser-based gas sensor for the detection of NO at a parts per billion (ppb) concentration level, typical of biomedical applications, have been investigated. The laser was operated at liquid nitrogen temperature near lambda = 5.2 microns. In the first configuration, a 100 m optical path length multi-pass cell was employed to enhance the NO absorption. In the second configuration, a technique based on cavity-enhanced spectroscopy (CES) was utilized, with an effective path length of 670 m. Both sensors enabled simultaneous analysis of NO and CO2 concentrations in exhaled air. The minimum detectable NO concentration was found to be 3 ppb with a multi-pass cell and 16 ppb when using CES. The two techniques are compared, and potential future developments are discussed.
Fabrication of versatile cladding light strippers and fiber end-caps with CO2 laser radiation
NASA Astrophysics Data System (ADS)
Steinke, M.; Theeg, T.; Wysmolek, M.; Ottenhues, C.; Pulzer, T.; Neumann, J.; Kracht, D.
2018-02-01
We report on novel fabrication schemes of versatile cladding light strippers and end-caps via CO2 laser radiation. We integrated cladding light strippers in SMA-like connectors for reliable and stable fiber-coupling of high-power laser diodes. Moreover, the application of cladding light strippers in typical fiber geometries for high-power fiber lasers was evaluated. In addition, we also developed processes to fuse end-caps to fiber end faces via CO2 laser radiation and inscribe the fibers with cladding light strippers near the end-cap. Corresponding results indicate the great potential of such devices as a monolithic and low-cost alternative to SMA connectors.
NASA Technical Reports Server (NTRS)
Abel, Robert W.; Christiansen, Walter H.; Li, Jian-Guo
1988-01-01
A proof of principle experiment to evaluate the efficacy of CO and H2O in increasing the power output for N2O and CO2 lasing mixtures has been conducted and theoretically analyzed for a blackbody radiation-pumped laser. The results for N2O-CO, CO2-CO, N2O-H2O and CO2-H2O mixtures are presented. Additions of CO to the N2O lasant increased power up to 28 percent for N2O laser mixtures, whereas additions of CO to the CO2 lasant, and the addition of H2O to both the CO2 and N2O lasants, resulted in decreased output power.
Abergel, Avraham; Gabay, Ilan; Fliss, Dan M; Katzir, Abraham; Gil, Ziv
2011-06-01
Laser soldering of a thick multilayer organ using conventional CO(2) lasers is ineffective. The purpose of this work was to develop a method for bonding the multilayer tissue of the upper aerodigestive tracts (UADT) without the need of sutures or stapling. Animal model. Academic research laboratory. The authors developed a multi-wavelength laser system, based on 2 fiber-optic lasers applied simultaneously. A highly absorbable CO(2) laser interacts with the muscular layer, and a nonabsorbable GaAs laser interacts with indocyanine-green solid albumin, placed between the mucosa and the muscular layer. The authors used an ex vivo porcine model to examine the capability of this system to effectively correct esophageal tears. The soldered esophagi burst pressure was >175 cm H(2)O (98% success rate) in 88 of the 90 experiments. A conventional CO(2) laser soldering resulted in insufficient bonding (mean burst pressure of 40 ± 7 cm H(2)O, n = 5), while the multi-wavelength laser system provided an ~9-fold tighter seal (359 ± 75.4 cm H(2)O, P < .0001, n = 15). Burst pressures after conventional suturing of the defect was significantly lower (106 ± 65.8 cm H(2)O, P < .001) than in the multi-wavelength laser system. Bonding of the UADT mucosa using a multi-wavelength, temperature-controlled laser soldering system can support significantly higher pressures then conventional CO(2) laser soldering and suture repair. The mean bonding pressure was 3.5-fold higher than the maximal swallowing pressure. Our findings provide a basis for implementation of new surgical tools for repair of esophageal perforations.
Aspects of CO2 laser engraving of printing cylinders.
Atanasov, P A; Maeno, K; Manolov, V P
1999-03-20
Results of the experimental and theoretical investigations of CO(2) laser-engraved cylinders are presented. The processed surfaces of test samples are examined by a phase-stepping laser interferometer, digital microscope, and computer-controlled profilometer. Fourier analysis is made on the patterns parallel to the axis of the laser-scribed test ceramic cylinders. The problem of the visually observed banding is discussed.
Simulation of planetary entry radiative heating with a CO2 gasdynamic laser
NASA Technical Reports Server (NTRS)
Lundell, J. H.; Dickey, R. R.; Howe, J. T.
1975-01-01
Heating encountered during entry into the atmospheres of Jupiter, Saturn, and Uranus is described, followed by a discussion of the use of a CO2 gasdynamic laser to simulate the radiative component of the heating. Operation and performance of the laser is briefly described. Finally, results of laser tests of some candidate heat-shield materials are presented.
Nemeth, A J
1993-10-01
The advances in laser surgery over the past decade have been remarkable and have significantly altered the management of a host of dermatologic disorders. This article focuses on the CO2 laser as a cutting and vaporization tool and reviews the features that distinguish CO2 laser-induced wounds from those created by a scalpel. Tissue welding, wound management after skin treatment with the visible light lasers based on the principle of selective photothermolysis, as well as the controversial field of low-energy laser therapy (biostimulation) are also addressed.
Orringer, Jeffrey S; Sachs, Dana L; Shao, Yuan; Hammerberg, Craig; Cui, Yilei; Voorhees, John J; Fisher, Gary J
2012-10-01
Fractionated ablative laser resurfacing has become a widely used treatment modality. Its clinical results are often found to approach those of traditional fully ablative laser resurfacing. To directly compare the molecular changes that result from fractionated and fully ablative carbon dioxide (CO(2)) laser resurfacing in photodamaged human skin. Photodamaged skin of 34 adult volunteers was focally treated at distinct sites with a fully ablative CO(2) laser and a fractionated CO(2) laser. Serial skin samples were obtained at baseline and several time points after treatment. Real-time reverse transcriptase polymerase chain reaction technology and immunohistochemistry were used to quantify molecular responses to each type of laser treatment. Fully ablative and fractionated CO(2) laser resurfacing induced significant dermal remodeling and collagen induction. After a single treatment, fractionated ablative laser resurfacing resulted in collagen induction that was approximately 40% to 50% as pronounced as that induced by fully ablative laser resurfacing. The fundamental cutaneous responses that result from fully ablative and fractionated carbon dioxide laser resurfacing are similar but differ in magnitude and duration, with the fully ablative procedure inducing relatively greater changes including more pronounced collagen induction. However, the molecular data reported here provide substantial support for fractionated ablative resurfacing as an effective treatment modality for improving skin texture. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
de Riese, Cornelia
2004-07-01
This presentation is designed as a brief overview of laser use in gynecology, for non-medical researchers involved in development of new laser techniques. The literature of the past decade is reviewed. Differences in penetration, absorption, and suitable delivery media for the beams dictate clinical application. The use of CO2 laser in the treatment of uterine cervical intraepithelial lesions is well established and indications as well as techniques have not changed over 30 years. The Cochrane Systematic Review from 2000 suggests no obviously superior technique. CO2 laser ablation of the vagina is also established as a safe treatment modality for VAIN. CO2 laser permits treatment of lesions with excellent cosmetic and functional results. The treatment of heavy menstrual bleeding by destruction of the endometrial lining using various techniques has been the subject of a 2002 Cochran Database Review. Among the compared treatment modalities are newer and modified laser techniques. Conclusion by reviewers is that outcomes and complication profiles of newer techniques compare favorably with the gold standard of endometrial resection. The ELITT diode laser system is one of the new successful additions. CO2 laser is also the dominant laser type used with laparoscopy for ablation of endometriotic implants. Myoma coagulation or myolysis with Nd:Yag laser through the laparoscope or hysteroscope is a conservative treatment option. Even MRI guided percutaneous approaches have been described. No long-term data are available.
Mahmoudzadeh, Majid; Rezaei-Soufi, Loghman; Farhadian, Nasrin; Jamalian, Seyed Farzad; Akbarzadeh, Mahdi; Momeni, Mohammadali; Basamtabar, Masome
2018-01-01
Introduction: Orthodontic treatment has many advantages such as esthetic improvement and self-esteem enhancement; yet it has some disadvantages such as increasing the risk of formation of white spot lesions, because it makes oral hygiene more difficult. It is rational to implement procedures to prevent these lesions. The present study was aimed to assess the effect of CO2 laser and fluoride varnish on the surface of the enamel surface microhardness around the orthodontic braces. Methods: Eighty extracted premolar teeth were selected, scaled, polished with nonfluoridated pumic and metal brackets were bonded to them. Then, they were randomly allocated to 5 groups: control (neither fluoride nor laser is used on enamel surfaces), fluoride (4 minutes fluoride varnish treatment of the enamel surfaces), CO2 laser (10.6 µm CO2 laser irradiation of the teeth), laserfluoride (fluoride application after laser irradiation) and fluoride-laser (fluoride was applied and then teeth were irradiated with laser). After surface treatment around brackets on enamel, the samples were stored in 0.1% thymol for less than 5 days and then they were exposed to a 10-day microbiological caries model. Microhardness values of enamel were evaluated with Vickers test. One sample of each group (5 teeth from 80 samples) was prepared for SEM (scanning electron microscopy) and the data from 75 remaining teeth were analyzed with analysis of variance (ANOVA) and chi-square tests (α =0.05). Results: Microhardness mean values from high to low were as follow: fluoride-laser, laser-fluoride, laser, fluoride and control. Microhardness in fluoride-laser group was significantly higher compared with that of the control group. Distribution adhesive remnant index (ARI) scores were significantly different between groups and most of bond failures occurred at the enamel-adhesive interface in groups 2 to 5 and at the adhesive-bracket interface in the control group. Conclusion: Combination of fluoride varnish and CO2 laser irradiation can reduce enamel demineralization around orthodontic brackets. PMID:29399311
Mahmoudzadeh, Majid; Rezaei-Soufi, Loghman; Farhadian, Nasrin; Jamalian, Seyed Farzad; Akbarzadeh, Mahdi; Momeni, Mohammadali; Basamtabar, Masome
2018-01-01
Introduction: Orthodontic treatment has many advantages such as esthetic improvement and self-esteem enhancement; yet it has some disadvantages such as increasing the risk of formation of white spot lesions, because it makes oral hygiene more difficult. It is rational to implement procedures to prevent these lesions. The present study was aimed to assess the effect of CO 2 laser and fluoride varnish on the surface of the enamel surface microhardness around the orthodontic braces. Methods: Eighty extracted premolar teeth were selected, scaled, polished with nonfluoridated pumic and metal brackets were bonded to them. Then, they were randomly allocated to 5 groups: control (neither fluoride nor laser is used on enamel surfaces), fluoride (4 minutes fluoride varnish treatment of the enamel surfaces), CO 2 laser (10.6 µm CO 2 laser irradiation of the teeth), laserfluoride (fluoride application after laser irradiation) and fluoride-laser (fluoride was applied and then teeth were irradiated with laser). After surface treatment around brackets on enamel, the samples were stored in 0.1% thymol for less than 5 days and then they were exposed to a 10-day microbiological caries model. Microhardness values of enamel were evaluated with Vickers test. One sample of each group (5 teeth from 80 samples) was prepared for SEM (scanning electron microscopy) and the data from 75 remaining teeth were analyzed with analysis of variance (ANOVA) and chi-square tests (α =0.05). Results: Microhardness mean values from high to low were as follow: fluoride-laser, laser-fluoride, laser, fluoride and control. Microhardness in fluoride-laser group was significantly higher compared with that of the control group. Distribution adhesive remnant index (ARI) scores were significantly different between groups and most of bond failures occurred at the enamel-adhesive interface in groups 2 to 5 and at the adhesive-bracket interface in the control group. Conclusion: Combination of fluoride varnish and CO2 laser irradiation can reduce enamel demineralization around orthodontic brackets.
Comparison between a CO2 and a Nd-YAG laser with fibertom system in the treatment of frenulum breve
NASA Astrophysics Data System (ADS)
Wozniak, Jakub; Dydowicz, Piotr; Jedrzejczak, Piotr; Opala, Tomasz; Wilczak, Maciej; Pisarska-Krawczyk, Magdalena; Pisarski, Tadeusz
1997-10-01
The study showed the treatment of frenulum breve in 24 patients. Nine of them were treated with CO2 and eight ones with Nd:YAG lasers. In seven males the classical surgical procedures were done. All patients were treated in Department of Reproduction, Institute of Gynecology and Obstetrics, Karol Marcinkowski School of Medical Sciences, Poznan, Poland between March 1995 and September 1996. All procedures were collected successful and no serious complications were observed. The all males are still under control in our department. The use of lasersurgery is the safe and efficient method in treatment of frenulum breve. Lasersurgery may be conducting as the out-patient procedure or one-day surgery because of possibility of NLA and local anesthesia. The use of CO2 seems to be the better method than Nd:YAG laser with fibertom system in treatment of frenulum breve because of shorter time of healing. There are no differences between hemostasis achieved by CO2 and Nd:YAG lasers. The incision effect is the same, when CO2 and Nd:YAG laser with fibertom system are used.
NASA Astrophysics Data System (ADS)
Qu, Zheng; Zhang, Zhaoguang; Ye, Jianguang; Yu, Jianbo
1999-09-01
This paper reports the clinical experience in transmyocardial laser revascularization (TMLR) with high power CO2 laser and evaluates the preliminary results of TMLR. TMLR may improve angina pectoris and myocardial perfusion significantly. To switch on the laser in proper order may be helpful to shorten duration of surgery. A gentle removal of fat on the apex may increase the successful transmyocardial penetration.
New refractive method for laser thermal keratoplasty with the Co:MgF2 laser.
Horn, G; Spears, K G; Lopez, O; Lewicky, A; Yang, X Y; Riaz, M; Wang, R; Silva, D; Serafin, J
1990-09-01
We have observed corneal curvature changes from laser thermal keratoplasty with a Co:MgF2 laser. We studied corneal curvature changes in rabbits and have identified specific treatment patterns and laser parameters that can correct myopia and astigmatism. These corneal changes, some as large as 8 diopters, have been stable for at least one year, and slitlamp examination demonstrates clear central corneas with normal appearance.
CO2 laser versus cold steel margin analysis following endoscopic excision of glottic cancer
2014-01-01
Objective To compare the suitability of CO2 laser with steel instruments for margin excision in transoral laser microsurgery. Methods Prospective randomized blinded study. Patients with glottic cancer undergoing laser resection were randomized to margin excision by either steel instruments or CO2 laser. Margins were analyzed for size, interpretability and degree of artifact by a pathologist who was blinded to technique. Results 45 patients were enrolled in the study with 226 total margins taken. 39 margins taken by laser had marked artifact and 0 were uninterpretable. 20 margins taken by steel instruments had marked artifact, and 2 were uninterpretable. Controlling for margin size, the laser technique was associated with increasing degrees of margin artifact (p = 0.210), but there was no difference in crude rates of uninterpretability (p = 0.24). Conclusion Laser margin excision is associated with a greater degree of artifact than steel instrument excision, but was not associated with higher rate of uninterpretability. PMID:24502856
NASA Technical Reports Server (NTRS)
Yu, Jirong; Trieu, Bo; Bai, Yingxin; Koch, Grady; Chen, Songsheng; Petzar, Paul; Singh, Upendra N.; Kavaya, Michael J.; Beyon, Jeffrey
2010-01-01
The design of a double pulsed, injection seeded, 2-micrometer compact coherent Differential absorption Lidar (DIAL) transmitter for CO2 sensing is presented. This system is hardened for ground and airborne applications. The design architecture includes three continuous wave lasers which provide controlled on and off line seeding, injection seeded power oscillator and a single amplifier operating in double pass configuration. As the derivative a coherent Doppler wind lidar, this instrument has the added benefit of providing wind information. The active laser material used for this application is a Ho: Tm:YLF crystal operates at the eye-safe wavelength. The 3-meter long folded ring resonator produces energy of 130-mJ (90/40) with a temporal pulse length around 220 nanoseconds and 530 nanosecond pulses for on and off lines respectively. The separation between the two pulses is on the order of 200 microseconds. The line width is in the order of 2.5MHz and the beam quality has an M(sup 2) of 1.1 times diffraction limited beam. A final output energy for a pair of both on and off pulses as high as 315 mJ (190/125) at a repetition rate of 10 Hz is achieved. The operating temperature is set around 20 C for the pump diode lasers and 10 C for the rod. Since the laser design has to meet high-energy as well as high beam quality requirements, close attention is paid to the laser head design to avoid thermal distortion in the rod. A side-pumped configuration is used and heat is removed uniformly by passing coolant through a tube slightly larger than the rod to reduce thermal gradient. This paper also discusses the advantage of using a long upper laser level life time laser crystal for DIAL application. In addition issues related to injection seeding with two different frequencies to achieve a transform limited line width will be presented.
Choudhri, Omar; Karamchandani, Jason; Gooderham, Peter; Steinberg, Gary K
2014-03-01
Lasers have a long history in neurosurgery, yet bulky designs and difficult ergonomics limit their use. With its ease of manipulation and multiple applications, the OmniGuide CO2 laser has reintroduced laser technology to the microsurgical resection of brain and spine lesions. This laser, delivered through a hollow-core fiber lined with a unidirectional mirror, minimizes energy loss and allows precise targeting. To analyze resections performed by the senior author from April 2009 to March 2013 of 58 cavernous malformations (CMs) in the brain and spine with the use of the OmniGuide CO2 laser, to reflect on lessons learned from laser use in eloquent areas, and to share data on comparisons of laser power calibration and histopathology. Data were collected from electronic medical records, radiology reports, operative room records, OmniGuide CO2 laser case logs, and pathology records. Of 58 CMs, approximately 50% were in the brainstem (30) and the rest were in supratentorial (26) and intramedullary spinal locations (2). Fifty-seven, ranging from 5 to 45 mm, were resected, with a subtotal resection in 1. Laser power ranged from 2 to 10 W. Pathology specimens showed minimal thermal damage compared with traditionally resected specimens with bipolar coagulation. The OmniGuide CO2 laser is safe and has excellent precision for the resection of supratentorial, brainstem, and spinal intramedullary CMs. No laser-associated complications occurred, and very low energy was used to dissect malformations from their surrounding hemosiderin-stained parenchymas. The authors recommend its use for deep-seated and critically located CMs, along with traditional tools.
NASA Astrophysics Data System (ADS)
Bailey, D. M.; Caine, K. M.; Miller, J. H. H.
2016-12-01
Continuous collection of carbon dioxide (CO2) concentrations is imperative in understanding seasonal and inter-annual variability of carbon feedbacks above thawing permafrost. Permafrost makes up one-quarter of the Earth's terrestrial surface and has the potential to release twice the amount of carbon than is currently in the atmosphere if global temperatures continue to increase. A collaborative effort with the University of Alaska - Fairbanks, NASA Goddard Space Flight Center, and our group at George Washington University is underway to monitor these feedbacks near Fairbanks, Alaska. In June 2016, we deployed an open-path tunable diode laser sensor along with a non-dispersive infrared (NDIR) sensor at the Bonanza Creek Long Term Ecological Research Site as an exploratory study for their use in collecting near-surface CO2 concentrations above thawing permafrost. The open-path instrument (OPI) collected spatially-integrated measurements approximately 1.5 meters above the surface of a young thermokarst bog over a 15-day period whereas the NDIR sensor collected localized measurements 1 meter above the surface for 16 days. Near-continuous measurements were achieved with the NDIR sensor which was limited only by the availability of solar-produced power. The OPI measurements were further limited by maintaining laser alignment under changing environmental conditions. However, the campaign achieved a nearly 80% duty cycle for the entire test period. Here we compare both the localized and spatially-integrated carbon dioxide measurements and their observed diurnal concentration cycles, whose magnitude showed a strong dependence on daily weather at the test site.
Standard guidelines of care: CO2 laser for removal of benign skin lesions and resurfacing.
Krupashankar, D S
2008-01-01
Resurfacing is a treatment to remove acne and chicken pox scars, and changes in the skin due to ageing. MACHINES: Both ablative and nonablative lasers are available for use. CO 2 laser is the gold standard in ablative lasers. Detailed knowledge of the machines is essential. INDICATIONS FOR CO 2 LASER: Therapeutic indications: Actinic and seborrheic keratosis, warts, moles, skin tags, epidermal and dermal nevi, vitiligo blister and punch grafting, rhinophyma, sebaceous hyperplasia, xanthelasma, syringomas, actinic cheilitis angiofibroma, scar treatment, keloid, skin cancer, neurofibroma and diffuse actinic keratoses. CO 2 laser is not recommended for the removal of tattoos. AESTHETIC INDICATIONS: Resurfacing for acne, chicken pox and surgical scars, periorbital and perioral wrinkles, photo ageing changes, facial resurfacing. PHYSICIANS' QUALIFICATIONS: Any qualified dermatologist (DVD or MD) may practice CO 2 laser. The dermatologist should possess postgraduate qualification in dermatology and should have had specific hands-on training in lasers either during postgraduation or later at a facility which routinely performs laser procedures under a competent dermatologist/plastic surgeon, who has experience and training in using lasers. For the use of CO 2 lasers for benign growths, a full day workshop is adequate. As parameters may vary in different machines, specific training with the available machine at either the manufacturer's facility or at another centre using the machine is recommended. CO 2 lasers can be used in the dermatologist's minor procedure room for the above indications. However, when used for full-face resurfacing, the hospital operation theatre or day care facility with immediate access to emergency medical care is essential. Smoke evacuator is mandatory. Detailed counseling with respect to the treatment, desired effects, possible postoperative complications, should be discussed with the patient. The patient should be provided brochures to study and also given adequate opportunity to seek information. Detailed consent forms need to be completed by the patients. Consent forms should include information on the machine used; possible postoperative course expected and postoperative complications. Preoperative photography should be carried out in all cases of resurfacing. Choice of the machine and the parameters depends on the site, type of lesion, result needed, and the physician's experience. Localized lesions can be treated under eutectic mixture of local anesthesia (EMLA) cream anesthesia or local infiltration anesthesia. Full-face resurfacing can be performed under general anesthesia. Proper postoperative care is important to avoid complications.
NASA Technical Reports Server (NTRS)
Abshire, James B.; Weaver, Clark J.; Riris, Haris; Mao, Jianping; Sun, Xiaoli; Allan, Graham R.; Hasselbrack, William; Browell, Edward V.
2011-01-01
We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.
Enhanced light emission near 2.7 μm from Er-Nd co-doped germanate glass
NASA Astrophysics Data System (ADS)
Bai, Gongxun; Tao, Lili; Li, Kefeng; Hu, Lili; Tsang, Yuen Hong
2013-04-01
Laser glass gain medium that can convert low cost 808 nm diode laser into 2.7 μm has attracted considerable interest due to its potential application for medical surgery fiber laser system. In this study, enhanced 2.7 μm emission has been achieved in Er3+:germanate glass by co-doping with Nd3+ ions under the excitation of an 808 nm diode laser. In the co-doped sample, the experimental results show that the harmful visible emissions via up-conversion were effectively restricted. The reduction of 1.5 μm emission was also detected in the co-doped sample, which indicates significant de-excitation of 4I13/2 Er3+ ion through energy transfer and non-radiative decay in Nd3+ ions. In conclusion, the 2.7 μm emission enhancement achieved was due to the increased optical absorption of 808 nm, efficient energy transfer (ET) with efficiency of 81.73% between Er3+ and Nd3+ ions, and shortening the lifetime of the lower lasing level 4I13/2 Er3+ in the co-doped sample. Therefore, Er3+/Nd3+ co-doped germanate glass could be used to fabricate fiber optical gain media for 2.7 μm laser generation.
Cutaneous pain effects induced by Nd:YAG and CO2 laser stimuli
NASA Astrophysics Data System (ADS)
Wang, Jia-Rui; Yu, Guang-Yuan; Yang, Zai-Fu; Chen, Hong-Xia; Hu, Dong-Dong; Zou, Xian-Biao
2012-12-01
The near infrared laser technique can activate cutaneous nociceptors with high specificity and reproducibility and be used in anti-riot equipment. This study aimed to explore cutaneous pain effect and determine the threshold induced by Nd:YAG and CO2 laser stimuli. The corresponding wavelength was 1.32μm and 10.6μm. The pain effect was assessed in three healthy subjects (1 woman and 2 men) on the skin of dorsum of both hands. The energy of each pulse and whether the subjects felt a painful sensation after each stimulus were recorded. A simplified Bliss Method was used to calculate the pain threshold which were determined under three pulse durations for Nd:YAG laser and one pulse duration for CO2 laser. As a result the pain thresholds were determined to be 5.6J/cm2, 5.4J/cm2 and 5.0J/cm2 respectively when using Nd:YAG laser, 4.0mm beam diameter, 8ms, 0.1s and 1s pulse duration. The pain threshold was 1.0J/cm2 when using CO2 laser, 4.0mm beam diameter and 0.1s pulse duration. We concluded that the threshold of cutaneous pain elicited by 1.32μm laser was independent upon the pulse duration when the exposure time ranged from 8ms to 1s. Under the same exposure condition, the threshold of cutaneous pain elicited by 1.32μm laser was higher than that elicited by 10.6μm laser.
A compact, rugged, high repetition rate CO2 laser incorporating catalyst
NASA Technical Reports Server (NTRS)
Schwarzenberger, P. M.; Matzangou, X.
1990-01-01
The principal design features and operating characteristics of a high repetition rate CO2 laser are outlined. The laser is a compact, rugged unit, completely sealed and incorporating an unheated solid catalyst. Stable operation has been successfully demonstrated over a temperature range of -35 C to 65 C.
A blackbody radiation-pumped CO2 laser experiment
NASA Technical Reports Server (NTRS)
Christiansen, W. H.; Insuik, R. J.; Deyoung, R. J.
1982-01-01
Thermal radiation from a high temperature oven was used as an optical pump to achieve lasing from CO2 mixtures. Laser output as a function of blackbody temperature and gas conditions is described. This achievement represents the first blackbody cavity pumped laser and has potential for solar pumping.
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Singh, Upendra N.; Petros, Mulugeta; Remus, Ruben; Yu, Jirong
2015-01-01
Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.
Conversion of laser energy to gas kinetic energy
NASA Technical Reports Server (NTRS)
Caledonia, G. E.
1975-01-01
Techniques for the gas phase absorption of laser radiation for conversion to gas kinetic energy are discussed. Absorption by inverse Bremsstrahlung, in which laser energy is converted at a gas kinetic rate in a spectrally continuous process, is briefly described, and absorption by molecular vibrational rotation bands is discussed at length. High pressure absorption is proposed as a means of minimizing gas bleaching and dissociation, the major disadvantages of the molecular absorption process. A band model is presented for predicting the molecular absorption spectra in the high pressure absorption region and is applied to the CO molecule. Use of a rare gas seeded with Fe(CO)5 for converting vibrational modes to translation modes is described.
Sealed-off CO2 laser with In-Au alloy sealing
NASA Astrophysics Data System (ADS)
Iehisa, N.; Fukaya, K.; Karube, N.
1986-02-01
The In-Au alloy sealing was found to satisfy all the requirements imposed on the sealed-off CO2 lasers. The sealing between different materials such as quartz, SUS 303, Si, and ZnSe was shown to withstand the thermal shock test, and gave the He leak rate lower than 1×10-9 atm cc/s both before and after the tests. It was also proved that the transmittance characteristics of dielectric coated output couplers did not change after the sealing. The sealed-off CO2 lasers with La1-xSrxCoO3 perovskite oxide cathodes sealed with this technique produced the operational life of 3000 h at the laser power level of 50 W/m.
Experimental Investigation of Airbreathing Laser Propulsion Engines: CO2TEA vs. EDL
NASA Astrophysics Data System (ADS)
Mori, Koichi; Sasoh, Akihiro; Myrabo, Leik N.
2005-04-01
Single pulse laboratory experiments were carried out with a high-power CO2 Transversely-Exited Atmospheric (TEA) laser using parabolic laser propulsion (LP) engines of historic interest: 1) an original Pirri/ AERL bell engine, and 2) a scaled-up 11-cm diameter version with identical geometry. The objective was to quantify the effects of pulse duration upon the impulse coupling coefficient performance — with pulse energy as the parametric variable. Performance data from the TEA laser are contrasted with former results derived from AVCO Everett Research Laboratory and PLVTS CO2 electron discharge lasers (EDL). The `short-pulse' 2-microsecond TEA laser tests generated results that were distinctively different from that of the `long-pulse' EDL sources. The TC-300 TEA laser employed an unstable resonator to deliver up to 380 joules, and the square output beam measured 15-cm on a side, with a hollow 8-cm center. A standard ballistic pendulum was employed to measure the performance.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-08
...). The workers were engaged in employment related to the production of infrared and CO 2 laser optics... 2 laser optics, and related materials, from 2009 to 2010 or from January- October 2010 compared to... that the workers' firm did not shift production of infrared and CO 2 laser optics, and related...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
...). The workers were engaged in employment related to the production of infrared and CO 2 laser optics... 2 laser optics, and related materials, from 2009 to 2010 or from January- October 2010 compared to... investigation revealed that the workers' firm did not shift production of infrared and CO 2 laser optics, and...
Modematic: a fast laser beam analyzing system for high power CO2-laser beams
NASA Astrophysics Data System (ADS)
Olsen, Flemming O.; Ulrich, Dan
2003-03-01
The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 describing test methods for laser beam parameters have been approved. To implement these methods in industry is difficult and especially for the infrared laser sources, such as the CO2-laser, the availabl analyzing systems are slow, difficult to apply and having limited reliability due to the nature of the detection methods. In an EUREKA-project the goal was defined to develop a laser beam analyzing system dedicated to high power CO2-lasers, which could fulfill the demands for an entire analyzing system, automating the time consuming pre-alignment and beam conditioning work required before a beam mode analyses, automating the analyzing sequences and data analysis required to determine the laser beam caustics and last but not least to deliver reliable close to real time data to the operator. The results of this project work will be described in this paper. The research project has led to the development of the Modematic laser beam analyzer, which is ready for the market.
367 cases of CO2 laser therapy on facial acne
NASA Astrophysics Data System (ADS)
Gao, Yunqing; Liu, Songhao; Zhang, You; Liu, T. C.
1996-09-01
Since 1989, we have cured 367 persons of facial acne of different course by using direct irradiation of high-power CO2 laser combing with operative therapy of low-power CO2 laser. The cure rate is 100 percent. In this paper, we stated the therapeutic approach. It was shown that this therapeutic approach is simple and effective, and its recurrence rate is zero. There are no cicatrices after healing. It is easy to accept it, and is worthy of extension.
Effect of surface-breakdown plasma on metal drilling by pulsed CO2-laser radiation
NASA Astrophysics Data System (ADS)
Arutiunian, P. V.; Baranov, V. Iu.; Bobkov, I. V.; Bol'Shakov, L. A.; Dolgov, V. A.
1988-03-01
The effect of low-threshold surface breakdown produced by short (5-microsec) CO2-laser pulses on the metal drilling process is investigated. Data on the interaction of metals with laser pulses having the same duration but different shape are shown to be different. The effect of the ambient atmospheric pressure on the laser drilling process is investigated.
Pulsed CO2 characterization for lidar use
NASA Technical Reports Server (NTRS)
Jaenisch, Holger M.
1992-01-01
An account is given of a scaled functional testbed laser for space-qualified coherent-detection lidar applications which employs a CO2 laser. This laser has undergone modification and characterization for inherent performance capabilities as a model of coherent detection. While characterization results show good overall performance that is in agreement with theoretical predictions, frequency-stability and pulse-length limitations severely limit the laser's use in coherent detection.
CO2-Doped Diamond: A Potential Solid-State CO2 Laser Material?
NASA Technical Reports Server (NTRS)
Tratt, D.
1994-01-01
This paper describes a novel concept for a solid-state CO subscript 2 laser medium which, by eschewing the gas-phase approach, may offer prospects for a compact, robust 9 - 11 (micro)m coherent source, coupled with the potentially superior frequency stability characteristics afforded by monolithic solid-state construction.
Alster, T S
1999-02-01
The development and integration of pulsed and scanned CO2 and erbium:YAG laser systems into mainstream surgical practice over the past years has revolutionized cutaneous resurfacing. These lasers are capable of delivering to skin high peak fluences to effect controlled tissue vaporization, while leaving an acceptably narrow zone of residual thermal damage. The inherent technological differences that exist between the two distant laser systems in terms of ablation depths, degree of thermal coagulation, and postoperative side-effects and complications guide patient selection and management. This article reviews the basic principles of CO2 and erbium:YAG laser resurfacing, including preoperative, intraoperative, and postoperative patient considerations. Side-effects and complications encountered after laser resurfacing are discussed with specific guidelines provided on their appropriate management. Anticipated future developments and cutting-edge research endeavors in cutaneous laser resurfacing are also briefly outlined.
QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL.
Ma, Yufei; Lewicki, Rafał; Razeghi, Manijeh; Tittel, Frank K
2013-01-14
An ultra-sensitive and selective quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor platform was demonstrated for detection of carbon monoxide (CO) and nitrous oxide (N2O). This sensor used a state-of-the art 4.61 μm high power, continuous wave (CW), distributed feedback quantum cascade laser (DFB-QCL) operating at 10°C as the excitation source. For the R(6) CO absorption line, located at 2169.2 cm(-1), a minimum detection limit (MDL) of 1.5 parts per billion by volume (ppbv) at atmospheric pressure was achieved with a 1 sec acquisition time and the addition of 2.6% water vapor concentration in the analyzed gas mixture. For the N2O detection, a MDL of 23 ppbv was obtained at an optimum gas pressure of 100 Torr and with the same water vapor content of 2.6%. In both cases the presence of water vapor increases the detected CO and N2O QEPAS signal levels as a result of enhancing the vibrational-translational relaxation rate of both target gases. Allan deviation analyses were performed to investigate the long term performance of the CO and N2O QEPAS sensor systems. For the optimum data acquisition time of 500 sec a MDL of 340 pptv and 4 ppbv was obtained for CO and N2O detection, respectively. To demonstrate reliable and robust operation of the QEPAS sensor a continuous monitoring of atmospheric CO and N2O concentration levels for a period of 5 hours were performed.
Experimental comparative study on morphological effects of different lasers on the liver.
Godlewski, G; Miro, L; Chevalier, J M; Bureau, J P
1982-01-01
Three types of laser radiation were compared as to their capabilities in hepatic surgery using 17 New Zealand rabbits. In four animals, subtotal scalpel lobectomy was performed, the hepatic pedicle being clamped. Hemostasis is obtained by means of argon or Nd YAG laser as long as the internal diameter of the vessels encountered is less than 4.5 mm. Nd YAG laser requires a power output four times higher than argon laser to obtain hemostasis. In six animals limited resection was performed by means of Nd YAG and CO2 lasers. CO2 radiation supplied insufficient hemostasis whenever the vessel diameter was more than 1 mm despite an excellent cutting power. Nd YAG radiation created an important necrosis zone due to thermal diffusion. In seven animals various focal hepatic lesions produced by the three types of laser were compared. Argon laser induced superficial and regularly round lesion, Nd YAG laser deeper, cauliflower-like lesions with thermal diffusion following especially vessels. Veins presented thrombosis of their blood content and coagulation necrosis of their wall. The amount of glycogenic granulation decreased. The CO2 laser induced very sharp punctual lesion without necrosis. Electron-microscopic sections revealed faint shadowy liver cells closet to the thermal source and bubbled mitochondria containing disrupted critea around the lesion. In later lesions Nd YAG laser produced more extensive fibrosis than argon or CO2 laser. After first clinical trials we believe that laser irradiation is actually an adjuvant safety factor in current hepatic surgery, whereas the Nd YAG laser could be of real interest in metastatic carcinoma destruction in liver.
Spectrally Tailored Pulsed Thulium Fiber Laser System for Broadband Lidar CO2 Sensing
NASA Technical Reports Server (NTRS)
Heaps, William S.; Georgieva, Elena M.; McComb, Timothy S.; Cheung, Eric C.; Hassell, Frank R.; Baldauf, Brian K.
2011-01-01
Thulium doped pulsed fiber lasers are capable of meeting the spectral, temporal, efficiency, size and weight demands of defense and civil applications for pulsed lasers in the eye-safe spectral regime due to inherent mechanical stability, compact "all-fiber" master oscillator power amplifier (MOPA) architectures, high beam quality and efficiency. Thulium fiber's longer operating wavelength allows use of larger fiber cores without compromising beam quality, increasing potential single aperture pulse energies. Applications of these lasers include eye-safe laser ranging, frequency conversion to longer or shorter wavelengths for IR countermeasures and sensing applications with otherwise tough to achieve wavelengths and detection of atmospheric species including CO2 and water vapor. Performance of a portable thulium fiber laser system developed for CO2 sensing via a broadband lidar technique with an etalon based sensor will be discussed. The fielded laser operates with approximately 280 J pulse energy in 90-150ns pulses over a tunable 110nm spectral range and has a uniquely tailored broadband spectral output allowing the sensing of multiple CO2 lines simultaneously, simplifying future potentially space based CO2 sensing instruments by reducing the number and complexity of lasers required to carry out high precision sensing missions. Power scaling and future "all fiber" system configurations for a number of ranging, sensing, countermeasures and other yet to be defined applications by use of flexible spectral and temporal performance master oscillators will be discussed. The compact, low mass, robust, efficient and readily power scalable nature of "all-fiber" thulium lasers makes them ideal candidates for use in future space based sensing applications.
Scaling studies of solar pumped lasers
NASA Astrophysics Data System (ADS)
Christiansen, W. H.; Chang, J.
1985-08-01
A progress report of scaling studies of solar pumped lasers is presented. Conversion of blackbody radiation into laser light has been demonstrated in this study. Parametric studies of the variation of laser mixture composition and laser gas temperature were carried out for CO2 and N2O gases. Theoretical analysis and modeling of the system have been performed. Reasonable agreement between predictions in the parameter variation and the experimental results have been obtained. Almost 200 mW of laser output at 10.6 micron was achieved by placing a small sapphire laser tube inside an oven at 1500 K the tube was filled with CO2 laser gas mixture and cooled by longitudinal nitrogen gas flow.
Scaling studies of solar pumped lasers
NASA Technical Reports Server (NTRS)
Christiansen, W. H.; Chang, J.
1985-01-01
A progress report of scaling studies of solar pumped lasers is presented. Conversion of blackbody radiation into laser light has been demonstrated in this study. Parametric studies of the variation of laser mixture composition and laser gas temperature were carried out for CO2 and N2O gases. Theoretical analysis and modeling of the system have been performed. Reasonable agreement between predictions in the parameter variation and the experimental results have been obtained. Almost 200 mW of laser output at 10.6 micron was achieved by placing a small sapphire laser tube inside an oven at 1500 K the tube was filled with CO2 laser gas mixture and cooled by longitudinal nitrogen gas flow.