Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W
2013-01-01
The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.
Gohean, Jeffrey R.; George, Mitchell J.; Pate, Thomas D.; Kurusz, Mark; Longoria, Raul G.; Smalling, Richard W.
2012-01-01
The purpose of this investigation is to utilize a computational model to compare a synchronized valveless pulsatile left ventricular assist device to continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous, pulsatile, valveless, dual piston positive displacement pump. These results were compared to measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared to the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device. PMID:23438771
Response of the Cardiovascular System to Vibration and Combined Stresses
1975-08-31
Canines were chronically instrumented for continuous measurements of ascending aortic flow ( Zepeda ), left ventricular pressure (Konigsberg), circum- flex...different animals. Each dog was chronically instrumented for continuous measuremernt of ascending aortic flow ( Zepeda ), left ventricular pressure...vibration protocol as those animals restrained vertically. METHODS Canines (16 to 22 kg) were chronically instrumented with electromagnetic flow cuffs ( Zepeda
O'Shea, Genevieve; Teuteberg, Jeffrey J; Severyn, Donald A
2013-03-01
Ventricular assist devices provide therapeutic options for patients with severe heart failure who have exhausted available medical therapies. With restoration of organ perfusion with ventricular assist devices, the heart failure resolves and quality of life and functional status improve. The current generation of continuous-flow devices present novel challenges to the clinical assessment of patients by substantially reducing or nearly eliminating any palpable pulse. Patients therefore generally have inadequate arterial pulsatility for most noninvasive monitoring devices such as pulse oximeters or automated blood pressure cuffs to work accurately. This article describes the function of continuous-flow devices and how this function affects common monitoring options, as well as how to clinically assess recipients of continuous-flow devices to promptly identify those whose condition may be deteriorating or who may be receiving inadequate perfusion.
Cornwell, William K; Tarumi, Takashi; Stickford, Abigail; Lawley, Justin; Roberts, Monique; Parker, Rosemary; Fitzsimmons, Catherine; Kibe, Julius; Ayers, Colby; Markham, David; Drazner, Mark H; Fu, Qi; Levine, Benjamin D
2015-12-15
Current-generation left ventricular assist devices provide circulatory support that is minimally or entirely nonpulsatile and are associated with marked increases in muscle sympathetic nerve activity (MSNA), likely through a baroreceptor-mediated pathway. We sought to determine whether the restoration of pulsatile flow through modulations in pump speed would reduce MSNA through the arterial baroreceptor reflex. Ten men and 3 women (54 ± 14 years) with Heartmate II continuous-flow left ventricular assist devices underwent hemodynamic and sympathetic neural assessment. Beat-to-beat blood pressure, carotid ultrasonography at the level of the arterial baroreceptors, and MSNA via microneurography were continuously recorded to determine steady-state responses to step changes (200-400 revolutions per minute) in continuous-flow left ventricular assist device pump speed from a maximum of 10,480 ± 315 revolutions per minute to a minimum of 8500 ± 380 revolutions per minute. Reductions in pump speed led to increases in pulse pressure (high versus low speed: 17 ± 7 versus 26 ± 12 mm Hg; P<0.01), distension of the carotid artery, and carotid arterial wall tension (P<0.05 for all measures). In addition, MSNA was reduced (high versus low speed: 41 ± 15 versus 33 ± 16 bursts per minute; P<0.01) despite a reduction in mean arterial pressure and was inversely related to pulse pressure (P=0.037). Among subjects with continuous-flow left ventricular assist devices, the restoration of pulsatile flow through modulations in pump speed leads to increased distortion of the arterial baroreceptors with a subsequent decline in MSNA. Additional study is needed to determine whether reduction of MSNA in this setting leads to improved outcomes. © 2015 American Heart Association, Inc.
Soucy, Kevin G; Bartoli, Carlo R; Phillips, Dustin; Giridharan, Guruprasad A; Sobieski, Michael A; Wead, William B; Dowling, Robert D; Wu, Zhongjun J; Prabhu, Sumanth D; Slaughter, Mark S; Koenig, Steven C
2017-06-01
Continuous-flow left ventricular assist devices (CF LVADs) are rotary blood pumps that improve mean blood flow, but with potential limitations of non-physiological ventricular volume unloading and diminished vascular pulsatility. In this study, we tested the hypothesis that left ventricular unloading with increasing CF LVAD flow increases myocardial flow normalized to left ventricular work. Healthy (n = 8) and chronic ischemic heart failure (IHF, n = 7) calves were implanted with CF LVADs. Acute hemodynamics and regional myocardial blood flow were measured during baseline (LVAD off, clamped), partial (2-4 L/min) and full (>4 L/min) LVAD support. IHF calves demonstrated greater reduction of cardiac energy demand with increasing LVAD support compared to healthy calves, as calculated by rate-pressure product. Coronary artery flows (p < 0.05) and myocardial blood flow (left ventricle (LV) epicardium and myocardium, p < 0.05) decreased with increasing LVAD support in normal calves. In the IHF model, blood flow to the septum, LV, LV epicardium, and LV myocardium increased significantly with increasing LVAD support when normalized to cardiac energy demand (p < 0.05). In conclusion, myocardial blood flow relative to cardiac demand significantly increased in IHF calves, thereby demonstrating that CF LVAD unloading effectively improves cardiac supply and demand ratio in the setting of ischemic heart failure.
Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak
2014-01-01
Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.
Heerdt, P M; Pond, C G; Kussman, M K; Triantafillou, A N
1993-01-01
Despite numerous technologic advances in intraoperative monitoring, the only methods routinely available for assessment of right ventricular function in lung transplant recipients are continuous measurement of right heart pressures and intermittent thermodilution determination of cardiac output and ejection fraction. Additional data may now be obtained with transesophageal echocardiography, although this technology is expensive and not widely available and requires diverting attention from a potentially unstable patient for data acquisition and analysis. Recently, a Doppler pulmonary artery catheter was introduced that measures beat-to-beat pulmonary artery blood flow-velocity, cross sectional area, and volume flow. Because of data indicating that acceleration of blood in the pulmonary artery (measured as the first derivative of either the velocity or flow waveform) is a sensitive indicator of right ventricular contractility, we have used waveforms obtained with the catheter for assessment of right ventricular pump function (stroke volume and peak pulmonary artery flow rate) and contractility in heart surgery patients. We report here our experience with this method in two patients undergoing left single lung transplantation.
Device Management and Flow Optimization on Left Ventricular Assist Device Support.
Tchoukina, Inna; Smallfield, Melissa C; Shah, Keyur B
2018-07-01
The authors discuss principles of continuous flow left ventricular assist device (LVAD) operation, basic differences between the axial and centrifugal flow designs and hemodynamic performance, normal LVAD physiology, and device interaction with the heart. Systematic interpretation of LVAD parameters and recognition of abnormal patterns of flow and pulsatility on the device interrogation are necessary for clinical assessment of the patient. Optimization of pump flow using LVAD parameters and echocardiographic and hemodynamics guidance are reviewed. Copyright © 2018 Elsevier Inc. All rights reserved.
Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S
Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard
2017-04-01
Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.
In vitro characterization of a magnetically suspended continuous flow ventricular assist device.
Kim, H C; Bearnson, G B; Khanwilkar, P S; Olsen, D B; Maslen, E H; Allaire, P E
1995-01-01
A magnetically suspended continuous flow ventricular assist device using magnetic bearings was developed aiming at an implantable ventricular assist device. The main advantage of this device includes no mechanical wear and minimal chance of blood trauma such, as thrombosis and hemolysis, because there is no mechanical contact between the stationary and rotating parts. The total system consists of two subsystems: the centrifugal pump and the magnetic bearing. The centrifugal pump is comprised of a 4 vane logarithmic spiral radial flow impeller and a brushless DC motor with slotless stator, driven by the back emf commutation scheme. Two radial and one thrust magnetic bearing that dynamically controls the position of the rotor in a radial and axial direction, respectively, contains magnetic coils, the rotor's position sensors, and feedback electronic control system. The magnetic bearing system was able to successfully suspend a 365.5g rotating part in space and sustain it for up to 5000 rpm of rotation. Average force-current square factor of the magnetic bearing was measured as 0.48 and 0.44 (kg-f/Amp2) for radial and thrust bearing, respectively. The integrated system demonstrated adequate performance in mock circulation tests by providing a 6 L/min flow rate against 100 mmHg differential pressure at 2300 rpm. Based on these in vitro performance test results, long-term clinical application of the magnetically suspended continuous flow ventricular assist device is very promising after system optimization with a hybrid system using both active (electromagnet) and passive (permanent magnets) magnet bearings.
Ghodsizad, Ali; Badiye, A; Zeriouh, M; Pae, W; Koerner, M M; Loebe, M
2016-12-14
Despite advances in pump technology, thromboembolic events and pump thrombosis are potentially life-threatening complications in patients with continuous flow ventricular assist devices. Here we describe a patient with pump thrombosis following LVAD HeartMate II implantation presenting with Aspirin and Plavix resistance and signs of acute hemolysis as manifested by high LDH, changing pump power, pulse index and reduced pump flows.
Grosman-Rimon, Liza; Billia, Filio; Fuks, Avi; Jacobs, Ira; A McDonald, Michael; Cherney, David Z; Rao, Vivek
2016-07-15
Surgically implanted continuous flow left ventricular assist devices (CF-LVADs) are currently used in patients with end-stage heart failure (HF). However, CF-LVAD therapy introduces a new set of complications and adverse events in these patients. Major adverse events with the CF-LVAD include right heart failure, vascular dysfunction, stroke, hepatic failure, and multi-organ failure, complications that may have inflammation as a common etiology. Our aim was to review the current evidence showing a relationship between these adverse events and elevated levels of inflammatory biomarkers in CF-LVAD recipients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Intraatrial baffle repair of isolated ventricular inversion with left atrial isomerism.
McElhinney, D B; Reddy, V M; Silverman, N H; Hanley, F L
1996-11-01
Isolated ventricular inversion with left atrial isomerism, partial anomalous pulmonary venous connection, and interruption of the inferior vena cava with azygos continuation to a right superior vena cava was diagnosed by echocardiography in a neonate. At 48 days of age, the patient underwent successful anatomic correction with redirection of flow from the superior vena cava and hepatic veins to the left-sided tricuspid valve, and flow from the pulmonary veins to the right-sided mitral valve. In the present report, the surgical techniques of this case are described, along with a survey of the surgical literature covering anatomic repair of isolated ventricular inversion.
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Good, Bryan C.; Deutsch, Steven; Manning, Keefe B.
2015-01-01
Purpose To investigate the effects of pulsatile and continuous pediatric ventricular assist (PVAD) flow and pediatric blood viscoelasticity on hemodynamics in a pediatric aortic graft model. Methods Hemodynamic parameters of pulsatility, along with velocity and wall shear stress (WSS), are analyzed and compared between Newtonian and viscoelastic blood models at a range of physiological pediatric hematocrits using computational fluid dynamics. Results Both pulsatile and continuous PVAD flow lead to a decrease in pulsatility (surplus hemodynamic energy (SHE), ergs/cm3) compared to healthy aortic flow but with continuous PVAD pulsatility up to 2.4 times lower than pulsatile PVAD pulsatility at each aortic outlet. Significant differences are also seen between the two flow modes in velocity and WSS. The higher velocity jet during systole with pulsatile flow leads to higher WSSs at the anastomotic toe and at the aortic branch bifurcations. The lower velocity but continuous flow jet leads to a much different flow field and higher WSSs into diastole. Under a range of physiological pediatric hematocrit (20-60%), both velocity and WSS can vary significantly with the higher hematocrit blood model generally leading to higher peak WSSs but also lower WSSs in regions of flow separation. Conclusions The large decrease in pulsatility seen from continuous PVAD flow could lead to complications in pediatric vascular development while the high WSSs during peak systole from pulsatile PVAD flow could lead to blood damage. Both flow modes lead to similar regions prone to intimal hyperplasia (IH) resulting from low time-averaged WSS (TAWSS) and high oscillatory shear index (OSI). PMID:26643646
Shah, Keyur B; Gunda, Sampath; Emani, Sitaramesh; Kanwar, Manreet K; Uriel, Nir; Colombo, Paolo C; Uber, Patricia A; Sears, Melissa L; Chuang, Joyce; Farrar, David J; Brophy, Donald F; Smallfield, George B
2017-11-01
Gastrointestinal (GI) bleeding is one of the most common complications after continuous-flow left ventricular assist device implantation. More than one third of patients with incident bleed go on to develop recurrent GI bleeding. Octreotide, a somatostatin analog, is proposed to reduce the risk of recurrent GI bleeding in this population. This multicenter, retrospective analysis evaluated 51 continuous-flow left ventricular assist device patients who received secondary prophylaxis with octreotide after their index GI bleed from 2009 to 2015. All patients had a hospitalization for GI bleed and received octreotide after discharge. Patient demographics, medical and medication history, and clinical characteristics of patients who rebled after receiving octreotide were compared with non-rebleeders. These data were also compared with matched historical control patients previously enrolled in the HMII (HeartMate II) clinical trials, none of whom received octreotide, to provide a context for the bleeding rates. Twelve patients (24%) who received secondary octreotide prophylaxis developed another GI bleed, whereas 39 (76%) did not. There were similar intergroup demographics; however, significantly more bleeders had a previous GI bleeding history before left ventricular assist device placement (33% versus 5%; P =0.02) and greater frequency of angiodysplasia confirmed during endoscopy (58% versus 23%; P =0.03). Fewer patients in this study experienced a recurrent GI bleed compared with a matched historical control group that did not receive octreotide (24% versus 43%; P =0.04). Patients with continuous-flow left ventricular assist device receiving secondary prophylaxis with octreotide had a significantly lower GI bleed recurrence compared with historical controls not treated with octreotide. Additional prospective studies are needed to confirm these data. © 2017 American Heart Association, Inc.
Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo
2018-05-22
Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.
Primary angioplasty for infarction due to isolated right ventricular artery occlusion.
Chahal, Anwar A; Kim, Min-Young; Borg, Alexander N; Al-Najjar, Yahya
2014-11-26
We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery (RCA), successfully treated by balloon angioplasty. A 58-year-old gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient's blood pressure dropped to 80/40 mmHg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient's symptoms. Repeat echocardiography showed complete resolution of the ST-elevation in leads V4R and V5R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d in-patient stay without any complications.
Ng, Boon C.; Timms, Daniel; Cohn, William E.
2018-01-01
Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9–15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states. PMID:29677212
Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David
2017-10-01
To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P <0.0001 for both). The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.
Bedzra, Edo K S; Dardas, Todd F; Cheng, Richard K; Pal, Jay D; Mahr, Claudius; Smith, Jason W; Shively, Kent; Masri, S Carolina; Levy, Wayne C; Mokadam, Nahush A
2017-12-01
To investigate the effect of pulmonary function testing on outcomes after continuous flow left ventricular assist device implantation. A total of 263 and 239 patients, respectively, had tests of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide preoperatively for left ventricular assist device implantations between July 2005 and September 2015. Kaplan-Meier analysis and multivariable Cox regressions were performed to evaluate mortality. Patients were analyzed in a single cohort and across 5 groups. Postoperative intensive care unit and hospital lengths of stay were evaluated with negative binomial regressions. There is no association of forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide with survival and no difference in mortality at 1 and 3 years between the groups (log rank P = .841 and .713, respectively). Greater values in either parameter were associated with decreased hospital lengths of stay. Only diffusing capacity of the lungs for carbon monoxide was associated with increased intensive care unit length of stay in the group analysis (P = .001). Ventilator times, postoperative pneumonia, reintubation, and tracheostomy rates were similar across the groups. Forced expiratory volume in 1 second and diffusing capacity of the lungs for carbon monoxide are not associated with operative or long-term mortality in patients undergoing continuous flow left ventricular assist device implantation. These findings suggest that these abnormal pulmonary function tests alone should not preclude mechanical circulatory support candidacy. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas
2011-12-01
As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Lee, Chih-Hsien; Wei, Jeng
The prevalence of end-stage heart failure (HF) is on the increase, however, the availability of donor hearts remains limited. Left ventricular assist devices (LVADs) are increasingly being used for treating patients with end-stage HF. LVADs are not only used as a bridge to transplantation but also as a destination therapy. HeartMate II, a new-generation, continuous-flow LVAD (cf-LVAD), is currently an established treatment option for patients with HF. Technological progress and increasing implantation of cf-LVADs have significantly improved survival in patients with end-stage HF. Here we report a case of a patient with end-stage HF who was successfully supported using cf-LVAD implantation with adjuvant tricuspid valve repair in a general district hospital.
Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Bartoli, Carlo R.; Koenig, Steven C.; Ionan, Constantine; Gillars, Kevin J.; Mitchell, Mike E.; Austin, Erle H.; Gray, Laman A.; Pantalos, George M.
2014-01-01
OBJECTIVE Despite progress with adult ventricular assist devices (VADs), limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation (ECMO) remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, ECMO was compared to either intraaortic balloon pump (IABP), pulsatile-flow (PF)VAD, or continuous-flow (CF)VAD support in a pediatric heart failure model. DESIGN Experimental. SETTING Large animal laboratory operating room. SUBJECTS Yorkshire piglets (n=47, 11.7±2.6 kg). INTERVENTIONS In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS and MAIN RESULTS Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption (VO2) were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired student t-tests compared baseline and heart failure conditions. One-way repeated-measures ANOVA compared heart failure, device support mode(s), and ECMO. Statistically significant (p<0.05) findings included: 1) improved left ventricular blood supply/demand ratio during PFVAD, CFVAD, and ECMO but not IABP support, 2) improved global myocardial blood supply/demand ratio during PFVAD, and CFVAD but not IABP or ECMO support, and 3) diminished pulsatility during ECMO and CFVAD but not IABP and PFVAD support. A profile of systems-based responses was established for each type of support. CONCLUSIONS Each type of pediatric VAD provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection. PMID:24108116
Chronic outpatient management of patients with a left ventricular assist device
Franzwa, Jennifer
2015-01-01
The use of mechanical circulatory support (MCS) as treatment for advanced heart failure (HF) has grown exponentially over the past 15 years. The continuous flow left ventricular assist device (CF-LVAD) has become the most used form of MCS in advanced HF, especially since approval of use as destination therapy (DT) and with the lack of organ availability. Long-term survival has improved and diligent outpatient management is thus particularly critical to achieve optimal outcomes. This review will discuss outpatient management strategies for patients with HF and a left ventricular assist device (LVAD). PMID:26793331
McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J
2014-01-01
A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P < .01). At follow-up (median, 312 days; range, 0-1429 days), the mean aortic insufficiency score remained low for the patients with central aortic valve closure (0.27 ± 0.46) in contrast to those without central aortic valve closure who experienced aortic insufficiency progression (0.78 ± 0.89; P = .02). In addition, the proportion of patients with more than mild aortic insufficiency was significantly less in the central aortic valve closure group (0% vs 18%; P = .05). The patients in the central aortic valve closure group were significantly older and had a greater incidence of renal failure at baseline. The 30-day mortality was greater in the central aortic valve closure group, but the late survival was similar between the 2 groups. No reoperations were required for recurrent aortic insufficiency. The results of our study have shown that repair of aortic insufficiency with a simple central coaptation stitch is effective and durable in left ventricular assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Muthiah, Kavitha; Gupta, Sunil; Otton, James; Robson, Desiree; Walker, Robyn; Tay, Andre; Macdonald, Peter; Keogh, Anne; Kotlyar, Eugene; Granger, Emily; Dhital, Kumud; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S
2014-08-01
The aim of this study was to determine the contribution of pre-load and heart rate to pump flow in patients implanted with continuous-flow left ventricular assist devices (cfLVADs). Although it is known that cfLVAD pump flow increases with exercise, it is unclear if this increment is driven by increased heart rate, augmented intrinsic ventricular contraction, or enhanced venous return. Two studies were performed in patients implanted with the HeartWare HVAD. In 11 patients, paced heart rate was increased to approximately 40 beats/min above baseline and then down to approximately 30 beats/min below baseline pacing rate (in pacemaker-dependent patients). Ten patients underwent tilt-table testing at 30°, 60°, and 80° passive head-up tilt for 3 min and then for a further 3 min after ankle flexion exercise. This regimen was repeated at 20° passive head-down tilt. Pump parameters, noninvasive hemodynamics, and 2-dimensional echocardiographic measures were recorded. Heart rate alteration by pacing did not affect LVAD flows or LV dimensions. LVAD pump flow decreased from baseline 4.9 ± 0.6 l/min to approximately 4.5 ± 0.5 l/min at each level of head-up tilt (p < 0.0001 analysis of variance). With active ankle flexion, LVAD flow returned to baseline. There was no significant change in flow with a 20° head-down tilt with or without ankle flexion exercise. There were no suction events. Centrifugal cfLVAD flows are not significantly affected by changes in heart rate, but they change significantly with body position and passive filling. Previously demonstrated exercise-induced changes in pump flows may be related to altered loading conditions, rather than changes in heart rate. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Yang, Ning; Deutsch, Steven; Paterson, Eric G.; Manning, Keefe B.
2013-01-01
Although there are many studies that focus on understanding the consequence of pumping mode (continuous vs. pulsatile) associated with ventricular assist devices (VADs) on pediatric vascular pulsatility, the impact on local hemodynamics has been largely ignored. Hence, we compare not only the hemodynamic parameters indicative of pulsatility but also the local flow fields in the aorta and the great vessels originating from the aortic arch. A physiologic graft anastomotic model is constructed based on a pediatric, patient specific, aorta with a graft attached on the ascending aorta. The flow is simulated using a previously validated second-order accurate Navier–Stokes flow solver based upon a finite volume approach. The major findings are: (1) pulsatile support provides a greater degree of vascular pulsatility when compared to continuous support, which, however, is still 20% less than pulsatility in the healthy aorta; (2) pulsatile support increases the flow in the great vessels, while continuous support decreases it; (3) complete VAD support results in turbulence in the aorta, with maximum principal Reynolds stresses for pulsatile support and continuous support of 7081 and 249 dyn/cm2, respectively; (4) complete pulsatile support results in a significant increase in predicted hemolysis in the aorta; and (5) pulsatile support causes both higher time-averaged wall shear stresses (WSS) and oscillatory shear indices (OSI) in the aorta than does continuous support. These findings will help to identify the risk of graft failure for pediatric patients with pulsatile and continuous VADs. PMID:24348881
Wu, Wei-Tao; Yang, Fang; Wu, Jingchun; Aubry, Nadine; Massoudi, Mehrdad; Antaki, James F.
2016-01-01
Continuous flow ventricular assist devices (cfVADs) provide a life-saving therapy for severe heart failure. However, in recent years, the incidence of device-related thrombosis (resulting in stroke, device-exchange surgery or premature death) has been increasing dramatically, which has alarmed both the medical community and the FDA. The objective of this study was to gain improved understanding of the initiation and progression of thrombosis in one of the most commonly used cfVADs, the Thoratec HeartMate II. A computational fluid dynamics simulation (CFD) was performed using our recently updated mathematical model of thrombosis. The patterns of deposition predicted by simulation agreed well with clinical observations. Furthermore, thrombus accumulation was found to increase with decreased flow rate, and can be completely suppressed by the application of anticoagulants and/or improvement of surface chemistry. To our knowledge, this is the first simulation to explicitly model the processes of platelet deposition and thrombus growth in a continuous flow blood pump and thereby replicate patterns of deposition observed clinically. The use of this simulation tool over a range of hemodynamic, hematological, and anticoagulation conditions could assist physicians to personalize clinical management to mitigate the risk of thrombosis. It may also contribute to the design of future VADs that are less thrombogenic. PMID:27905492
Song, Xinwei; Wood, Houston G; Olsen, Don
2004-04-01
The continuous flow ventricular assist device (VAD) is a miniature centrifugal pump, fully suspended by magnetic bearings, which is being developed for implantation in humans. The CF4 model is the first actual prototype of the final design product. The overall performances of blood flow in CF4 have been simulated using computational fluid dynamics (CFD) software: CFX, which is commercially available from ANSYS Inc. The flow regions modeled in CF4 include the inlet elbow, the five-blade impeller, the clearance gap below the impeller, and the exit volute. According to different needs from patients, a wide range of flow rates and revolutions per minute (RPM) have been studied. The flow rate-pressure curves are given. The streamlines in the flow field are drawn to detect stagnation points and vortices that could lead to thrombosis. The stress is calculated in the fluid field to estimate potential hemolysis. The stress is elevated to the decreased size of the blood flow paths through the smaller pump, but is still within the safe range. The thermal study on the pump, the blood and the surrounding tissue shows the temperature rise due to magnetoelectric heat sources and thermal dissipation is insignificant. CFD simulation proved valuable to demonstrate and to improve the performance of fluid flow in the design of a small size pump.
Kobayashi, S; Owada, N; Yambe, T; Nitta, S; Fukuju, T; Hongoh, T; Hashimoto, H
1999-08-01
A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.
Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J
2011-02-08
Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.
Bhat, Sindhoor; Mathew, Jayakala; Balakrishnan, Komrakshi R; Krishna Kumar, Ramarathnam
One of the most devastating complications of continuous flow left ventricular devices (CFLVADS) is stroke, with a higher incidence in HeartWare Ventricular Assist Device (HVAD) as compared with HEARTMATE II. The reason for the observed difference in stroke rates is unclear. Because outflow graft diameters are different, we hypothesized that this could contribute to the difference in stroke rates. A computational fluid-structure interaction model was created from the computed tomography (CT) scan of a patient. Pressures were used as the boundary condition and the flow through the cerebral vessels was derived as outputs. Flow into the innominate artery was very sensitive to the anastomosis angle for a 10 mm as compared with a 14 mm graft, with the net innominate flow severely compromised with a 10 mm graft at 45° angle. Aortic insufficiency seems to affect cerebral blood flow nonlinearly with an 80% decrease at certain angles of outflow graft anastomosis. Arterial return in to the arch through a narrow graft has important jet effects and results in significant flow perturbations in the aortic arch and cerebral vessels and stasis. A 10 mm graft is more sensitive to angle of insertion than a 14 mm graft. Under some conditions, serious hypoperfusion of the innominate artery is possible. Aortic incompetence results in significant decrease of cerebral blood flow. No stasis was found in the pulsatile flow compared with LVAD flow.
Tsiouris, Athanasios; Paone, Gaetano; Nemeh, Hassan W; Brewer, Robert J; Borgi, Jamil; Hodari, Arielle; Morgan, Jeffrey A
2015-01-01
Continuous-flow (CF) left ventricular assist devices (LVADs) have become the standard of care for patients with advanced heart failure refractory to optimal medical therapy. The goal of this study was to review our 7 year single institutional experience with CF LVADs. Mean age was 50.4 + 12.5 (17-69) years for bridge-to-transplantation (BTT) patients and 57.6 + 10.4 (31-81) years for destination therapy (DT) patients (p < 0.001). Overall, 38 patients (26%) were female and 58 (41%) were African American. Etiology of heart failure was ischemic in 54 patients (37%) and nonischemic in 93 patients (63%). Overall survival at 30 days, 6 months, 12 months, and 2 years was 93%, 89%, 84%, and 81%, respectively. Gastrointestinal bleeding (GIB) was the most common complication (24%), followed by stroke (18%), right ventricular (RV) failure (18%), ventilator-dependent respiratory failure (10%), reoperation for bleeding (10%), and driveline infection (9%). These data demonstrate excellent survival with low mortality for both BTT and DT patients on long-term LVAD support. However, for LVAD therapy to become the gold standard for long-term treatment of end-stage heart failure and a plausible alternative to heart transplantation, we need to continue to improve the incidence of frequent postoperative complications, such as RV failure, driveline infections, strokes, and GIB.
Fukushima, Norihide; Tatsumi, Eisuke; Seguchi, Osamu; Takewa, Yoshiaki; Hamasaki, Toshimitsu; Onda, Kaori; Yamamoto, Haruko; Hayashi, Teruyuki; Fujita, Tomoyuki; Kobayashi, Junjiro
2018-06-08
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. The purpose of this study (NCVC-BTD_01, National Cerebral and Cardiovascular Center-Bridge to Dicision_01) is to assess the safety and effectiveness of the newly developed extracorporeal continuous-flow ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing (BR16010) use as a bridge-to-decision therapy for patients with severe heart failure or refractory cardiogenic shock. NCVC-BTD_01 is a single-center, single-arm, open-label, exploratory, medical device, investigator-initiated clinical study. It is conducted at the National Cerebral and Cardiovascular Center in Japan. A total of nine patients will be enrolled in the study. The study was planned using Simon's minimax two-stage phase design. The primary endpoint is a composite of survival free of device-related serious adverse events and complications during device support. For left ventricular assistance, withdrawal of a trial device due to cardiac function recovery or exchange to other ventricular assist devices (VADs) for the purpose of bridge to transplantation (BTT) during 30 days after implantation will be considered study successes. For right ventricular assistance, withdrawal of tal device due to right ventricular function recovery within 30 days after implantation will be considered a study success. Secondary objectives include changes in brain natriuretic peptide levels (7 days after implantation of a trial device and the day of withdrawal of a trial device), period of mechanical ventricular support, changes in left ventricular ejection fraction (7 days after implantation of a trial device and the day of withdrawal of a trial device), and changes in left ventricular diastolic dimension (7 days after implantation of a trial device and the day of withdrawal of a trial device). We will disseminate the findings through regional, national, and international conferences and through peer-reviewed journals. UMIN Clinical Trials Registry (UMIN-CTR; R000033243) registered on 8 September 2017.
Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam
2017-05-01
Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.
Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito
2006-12-01
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.
Gómez Bueno, Manuel; Segovia Cubero, Javier; Serrano Fiz, Santiago; Ugarte Basterrechea, Juan; Hernández Pérez, Francisco José; Goirigolzarri Artaza, Josebe; Castedo Mejuto, Evaristo; Burgos Lázaro, Raúl; García Montero, Carlos; Moñivas Palomero, Vanessa; Mingo Santos, Susana; González Román, Ana Isabel; Álvarez Avelló, José Manuel; Vidal Fernández, Mercedes; Forteza Gil, Alberto; Alonso-Pulpón, Luis
2017-09-01
Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Hakim, R; Black, P M
1998-01-01
After the initial description of normal pressure hydrocephalus (NPH) and its clinical triad, there has been a continuous interest from clinicians and researchers to set different diagnostic criteria that would make the selection of candidates for shunt surgery easier and more precise. A preliminary group of 12 patients was given a diagnosis of idiopathic normal pressure hydrocephalus by clinical and radiologic criteria. Each patient underwent two different tests: a magnetic resonance imaging-cerebrospinal fluid (MRI-CSF) flow study and a lumbo-ventricular perfusion test. The purpose was to compare the correlation of the results obtained with these tests and the clinical results obtained after CSF diversion. Eleven patients were given shunts and one was managed with lumbar punctures. One year after treatment, 10 of the 12 patients had improved with good results. The MRI-CSF flow studies were reliable in six patients; there were five false negatives and one false positive. The lumbo-ventricular perfusion test showed reliability in nine patients; there were two false negatives and one false positive. In only three patients were the results of both of these tests in accordance with the outcome. Even though there are few patients in this study so far, the data suggests that at the present time the most predictive guides for the diagnosis of NPH and its outcome after shunting are the clinical criteria and the radiological findings in computed tomography (CT) and/or MRI rather than lumbo-ventricular perfusion and CSF flow studies.
Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M
2010-10-01
Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.
Zhang, Qi; Gao, Bin; Chang, Yu
2017-02-27
BACKGROUND Partial support, as a novel support mode, has been widely applied in clinical practice and widely studied. However, the precise mechanism of partial support of LVAD in the intra-ventricular flow pattern is unclear. MATERIAL AND METHODS In this study, a patient-specific left ventricular geometric model was reconstructed based on CT data. The intra-ventricular flow pattern under 3 simulated conditions - "heart failure", "partial support", and "full support" - were simulated by using fluid-structure interaction (FSI). The blood flow pattern, wall shear stress (WSS), time-average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated to evaluate the hemodynamic effects. RESULTS The results demonstrate that the intra-ventricular flow pattern is significantly changed by the support level of BJUT-II VAD. The intra-ventricular vortex was enhanced under partial support and was eliminated under full support, and the high OSI and RRT regions changed from the septum wall to the cardiac apex. CONCLUSIONS In brief, the support level of the BJUT-II VAD has significant effects on the intra-ventricular flow pattern. The partial support mode of BJUT-II VAD can enhance the intra-ventricular vortex, while the distribution of high OSI and RRT moved from the septum wall to the cardiac apex. Hence, the partial support mode of BJUT-II VAD can provide more benefit for intra-ventricular flow pattern.
Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe
2018-05-08
Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index <2 (OR 3.3 [1.7-6.1], p = 0.001), a right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index <300 mm Hg/ml/m (OR 4.3 [2.5-7.3], p < 0.001), and a United Network for Organ Sharing modified Model for End-Stage Liver Disease Excluding INR score >17 (OR 3.5 [1.9-6.9], p < 0.001) as the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.
Effect of atrial systole on canine and porcine coronary blood flow.
Bellamy, R F
1981-09-01
A feature of phasic coronary flow patterns recorded in conscious chronically instrumented dogs is the atrial cove--a transient depression of arterial flow that occurs during atrial systole. The association between the hemodynamic effects of atrial systole and the atrial cove was studied in anesthetized dogs and pigs with complete heart block. Many atrial coves are available for study in these preparations because atrial activity continues unabated during the diastolic ventricular arrest that follows cessation of electrical pacing. The effect of atrial systole is to translate the pressure-flow relation found during diastole to a higher intercept pressure without change in slope. The increase in the intercept pressure equals the increase in intramyocardial pressure measured with microtransducers embedded in the left ventricular wall. The decrement in flow during the atrial cove is a direct function of the change in intramyocardial pressure and an inverse function of coronary vascular resistance. Each atrial systole is associated with a forward flow transient in the coronary veins, the peak of which occurs at the same instant as does the nadir of atrial flow. These data suggest that the coronary vessels are acting as collapsible tubes and that the waterfall model of the coronary circulation is applicable. The following sequence is proposed to account for the atrial cove. Atrial systole ejects a bolus of blood into the left ventricle increasing both ventricular cavity and intramyocardial pressures. The increase in intramyocardial pressure raises the back pressure opposing coronary flow, reducing the arterial perfusion pressure gradient and causing flow to fall.
Functional morphology and patterns of blood flow in the heart of Python regius.
Starck, J Matthias
2009-06-01
Brightness-modulated ultrasonography, continuous-wave Doppler, and pulsed-wave Doppler-echocardiography were used to analyze the functional morphology of the undisturbed heart of ball pythons. In particular, the action of the muscular ridge and the atrio-ventricular valves are key features to understand how patterns of blood flow emerge from structures directing blood into the various chambers of the heart. A step-by-step image analysis of echocardiographs shows that during ventricular diastole, the atrio-ventricular valves block the interventricular canals so that blood from the right atrium first fills the cavum venosum, and blood from the left atrium fills the cavum arteriosum. During diastole, blood from the cavum venosum crosses the muscular ridge into the cavum pulmonale. During middle to late systole the muscular ridge closes, thus prohibiting further blood flow into the cavum pulmonale. At the same time, the atrio-ventricular valves open the interventricular canal and allow blood from the cavum arteriosum to flow into the cavum venosum. In the late phase of ventricular systole, all blood from the cavum pulmonale is pressed into the pulmonary trunk; all blood from the cavum venosum is pressed into both aortas. Quantitative measures of blood flow volume showed that resting snakes bypass the pulmonary circulation and shunt about twice the blood volume into the systemic circulation as into the pulmonary circulation. When digesting, the oxygen demand of snakes increased tremendously. This is associated with shunting more blood into the pulmonary circulation. The results of this study allow the presentation of a detailed functional model of the python heart. They are also the basis for a functional hypothesis of how shunting is achieved. Further, it was shown that shunting is an active regulation process in response to changing demands of the organism (here, oxygen demand). Finally, the results of this study support earlier reports about a dual pressure circulation in Python regius.
Tamez, Daniel; LaRose, Jeffrey A.; Shambaugh, Charles; Chorpenning, Katherine; Soucy, Kevin G; Sobieski, Michael A; Sherwood, Leslie; Giridharan, Guruprasad A; Monreal, Gretel; Koenig, Steven C; Slaughter, Mark S
2014-01-01
Implantation of ventricular assist devices (VADs) for treatment of end-stage heart failure (HF) falls decidedly short of clinical demand, which exceeds 100,000 HF patients per year. VAD implantation often requires major surgical intervention with associated risk of adverse events and long recovery periods. To address these limitations, HeartWare, Inc. (Miami Lakes, FL) has developed a platform of miniature ventricular devices with progressively reduced surgical invasiveness and innovative patient peripherals. One surgical implant concept is a transapical version of the miniaturized left ventricular assist device (MVAD). The HeartWare MVAD Pump® is a small, continuous flow, full-support device that has a displacement volume of 22mL. A new cannula configuration has been developed for transapical implantation, where the outflow cannula is positioned across the aortic valve. The two primary objectives for this feasibility study were to evaluate anatomic fit and surgical approach and efficacy of the transapical MVAD configuration. Anatomic fit and surgical approach were demonstrated using human cadavers (n=4). Efficacy was demonstrated in acute (n =2) and chronic (n = 1) bovine model experiments and assessed by improvements in hemodynamics, biocompatibility, flow dynamics, and histopathology. Potential advantages of the MVAD Pump include flow support in the same direction as the native ventricle, elimination of cardiopulmonary bypass, and minimally-invasive implantation. PMID:24399057
Topilsky, Yan; Oh, Jae K; Atchison, Fawn W; Shah, Dipesh K; Bichara, Valentina M; Schirger, John A; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-02-01
Continuous-flow left ventricular assist devices (LVADs) have become part of the standard of care for the treatment of advanced heart failure. However, knowledge of normal values for transthoracic echocardiographic examination and measurements in these patients are lacking. All transthoracic echocardiographic examinations in 63 consecutive patients, performed 90 and 180 days after surgery with the implantation of a HeartMate II continuous-flow LVAD between February 2007 and January 2010, were retrospectively analyzed. All patients had to be outpatients at 3 and 6 months after surgery and considered stable on LVAD therapy (New York Heart Association class I or II and no need for inotropes, intravenous furosemide, or hospitalization). End-diastolic and end-systolic diameters and left ventricular mass decreased considerably compared with baseline measurements before LVAD implantation. Mitral inflow deceleration time increased (188 ± 70 vs 132.5 ± 27 msec, P = .009) and left atrial volume (84.1 ± 33 vs 141.7 ± 62 mL, P = .003) and E/e' ratio decreased (20.3 ± 9 vs 26 ± 11, P = .01), all consistent with decreased left ventricular filling pressure. Estimated right ventricular (RV) and right atrial pressure decreased significantly (34.1 ± 10 vs 51.7 ± 14 mm Hg and 9.5 ± 5 vs 14.4 ± 5 mm Hg, respectively, P < .0001 for both). Quantitatively estimated RV function (P = .02), RV fractional area change (27.9 ± 10% vs 37.4 ± 10.9%, P < .0001), and the RV index of myocardial performance (0.32 ± 0.1 vs 0.65 ± 0.2 vs 0.32 ± .01, P < .0001) improved, suggesting improved RV efficiency. LVAD therapy resulted in significant decreases in the severity of mitral regurgitation. Tricuspid regurgitation improved in patients who had concurrent tricuspid surgical correction and was unchanged otherwise. Aortic regurgitation severity increased 3 months after LVAD implantation. There were no significant differences in any of the echocardiographic parameters in the 6-month evaluation compared with the 3-month evaluation. This is the first report of selected typical echocardiographic values in a group of stable patients with normally functioning HeartMate II continuous-flow LVADs. A stable functioning continuous LVAD is associated with evidence of efficient unloading of the left ventricle, improved RV function, significant improvement in mitral regurgitation, improvement in tricuspid regurgitation only in patients undergoing repair, and increased aortic regurgitation. These normal data provide a basis for future echocardiographic studies after LVAD implantation. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Mycobacterium chimaera left ventricular assist device infections.
Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S
2017-06-01
A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.
Pereira, Naveen L; Chen, Dong; Kushwaha, Sudhir S; Park, Soon J
2010-10-01
The recommended anticoagulation regimen during continuous-flow axial left ventricular assist device (LVAD) support is aspirin and warfarin with a targeted international normalized ratio of 2.0-3.0. We report two patients in whom recurrent gastrointestinal bleeding during LVAD support necessitated discontinuation of this anti-thrombotic regimen for a year or more. Despite this, neither patients developed thrombotic complications during 29 patient-months of follow-up. An acquired von Willebrand factor (VWF) abnormality reflected by the absence or decreased abundance of the highest molecular weight multimers was demonstrated in both patients. The gold standard test for platelet function, light transmission platelet aggregometry was measured in one patient and was normal, indicative that the predominant abnormality in the coagulation profile of these patients is an acquired VWF syndrome. Clinical trials are required to address the question whether it is safe to discontinue anticoagulation in LVAD patients with acquired VWF abnormalities.
Hyler, Stefan; Pischke, Søren E; Halvorsen, Per Steinar; Espinoza, Andreas; Bergsland, Jacob; Tønnessen, Tor Inge; Fosse, Erik; Skulstad, Helge
2015-04-01
Sensitive methods for the early detection of myocardial dysfunction are still needed, as ischemia is a leading cause of decreased ventricular function during and after heart surgery. The aim of this study was to test the hypothesis that low-grade ischemia could be detected quantitatively by a miniaturized epicardial ultrasound transducer (Ø = 3 mm), allowing continuous monitoring. In 10 pigs, transducers were positioned in the left anterior descending and circumflex coronary artery areas. Left ventricular pressure was obtained by a micromanometer. The left internal mammary artery was grafted to the left anterior descending coronary artery, which was occluded proximal to the anastomosis. Left internal mammary artery flow was stepwise reduced by 25%, 50%, and 75% for 18 min each. From the transducers, M-mode traces were obtained, allowing continuous tissue velocity traces and displacement measurements. Regional work was assessed as left ventricular pressure-displacement loop area. Tissue lactate measured from intramyocardial microdialysis was used as reference method to detect ischemia. All steps of coronary flow reduction demonstrated reduced peak systolic velocity (P < .05) and regional work (P < .01).The decreases in peak systolic velocity and regional work were closely related to the degree of ischemia, demonstrated by their correlations with lactate (R = -0.74, P < .01, and R = -0.64, P < .01, respectively). The circumflex coronary artery area was not affected by any of the interventions. The epicardially attached miniaturized ultrasound transducer allowed the precise detection of different levels of coronary flow reduction. The results also showed a quantitative and linear relationship among coronary flow, ischemia, and myocardial function. Thus, the ultrasound transducer has the potential to improve the monitoring of myocardial ischemia and to detect graft failure during and after heart surgery. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad
2017-12-01
This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod
2018-05-29
Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.
Topilsky, Yan; Oh, Jae K; Shah, Dipesh K; Boilson, Barry A; Schirger, John A; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-03-01
The purpose of the study was to identify echocardiographic predictors of adverse outcome in patients implanted with continuous-flow left ventricular assist devices (LVAD). Continuous flow LVAD have become part of the standard of care for the treatment of advanced heart failure. However, knowledge of echocardiographic predictors of outcome after LVAD are lacking. Overall, 83 patients received continuous-flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, California) from February 2007 to June 2010. The LVAD database, containing various echocardiographic parameters, was examined to analyze their influence on in-hospital mortality, a compound cardiac event (in-hospital mortality or acute right ventricular [RV] dysfunction), and long-term mortality. Eight patients died before discharge (operative mortality 9.6%), and another 15 patients were considered to have acute RV dysfunction immediately after surgery. Patients with relatively small left ventricular end-diastolic diameters (<63 mm) had significantly higher risk for in-hospital mortality (odds ratio [OR]: 0.9; 95% confidence interval [CI]: 0.83 to 0.99; p = 0.04) or occurrence of the compound cardiac event (OR: 0.89; 95% CI: 0.84 to 0.95; p < 0.001). The most significant predictor of outcome was the decreased timing interval between the onset and the cessation of tricuspid regurgitation flow corrected for heart rate (TRDc), a surrogate for early systolic equalization of RV and right atrial pressure. Short TRDc predicted in-hospital mortality (OR: 0.85; 95% CI: 0.74 to 0.97; p = 0.01) and the compound cardiac event (OR: 0.83; 95% CI: 0.74 to 0.91; p < 0.0001). Multivariate analysis based on a logistic regression model demonstrated that the accuracy of predicting the 30-day compound adverse outcome was improved with the addition of echocardiographic variables when added to the commonly used hemodynamic or clinical scores. TRDc predicted long-term survival, with adjusted risk ratios of 0.89 for death from any cause (95% CI: 0.83 to 0.96; p = 0.003) and 0.88 for cardiac-related death (95% CI: 0.77 to 0.98; p = 0.03). The presence of either a relatively small left ventricle (<63 mm) or early systolic equalization of RV and right atrial pressure (short TRDc) demonstrated by echocardiography is associated with increased 30-day morbidity and mortality. Prediction of early adverse outcomes by echocardiographic parameters is additive to laboratory or hemodynamic variables. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Compostella, Leonida; Russo, Nicola; Setzu, Tiziana; Bottio, Tomaso; Compostella, Caterina; Tarzia, Vincenzo; Livi, Ugolino; Gerosa, Gino; Iliceto, Sabino; Bellotto, Fabio
2015-01-01
An increasing number of patients with end-stage heart failure are being treated with continuous-flow left ventricular assist devices (cf-LVADs). These patients provide new challenges to the staff in exercise-based cardiac rehabilitation (CR) programs. Even though experience remains limited, it seems that patients supported by cf-LVADs may safely engage in typical rehabilitative activities, provided that some attention is paid to specific aspects, such as the presence of a short external drive line. In spite of initial physical deconditioning, CR allows progressive improvement of symptoms such as fatigue and dyspnea. Intensity of rehabilitative activities should ideally be based on measured aerobic capacity and increased appropriately over time. Regular, long-term exercise training results in improved physical fitness and survival rates. Appropriate adjustment of cf-LVAD settings, together with maintenance of adequate blood volume, provides maximal output, while avoiding suction effects. Ventricular arrhythmias, although not necessarily constituting an immediate life-threatening situation, deserve treatment as they could lead to an increased rate of hospitalization and poorer quality of life. Atrial fibrillation may worsen symptoms of right ventricular failure and reduce exercise tolerance. Blood pressure measurements are possible in cf-LVAD patients only using a Doppler technique, and a mean blood pressure ≤80 mmHg is considered "ideal." Some patients may present with orthostatic intolerance, related to autonomic dysfunction. While exercise training constitutes the basic rehabilitative tool, a comprehensive intervention that includes psychological and social support could better meet the complex needs of patients in which cf-LVAD may offer prolonged survival.
Time course of pressure and flow in ascending aorta during ejection.
Perlini, S; Soldà, P L; Piepoli, M; Calciati, A; Paro, M; Marchetti, G; Meno, F; Finardi, G; Bernardi, L
1991-02-01
To analyze aortic flow and pressure relationships, 10 closed-chest anaesthetised dogs were instrumented with electromagnetic aortic flow probes and micromanometers in the left ventricle and ascending aorta. Left ventricular ejection time was divided into: time to peak flow (T1) (both pressure and flow rising), peak flow to peak pressure time (T2) (pressure rising, flow decreasing), and peak pressure to dicrotic notch time (T3) (pressure and flow both decreasing). These time intervals were expressed as percent of total ejection time. Load-active interventions rose markedly T2 (from 4.2 +/- 5.5 to 19.4 +/- 3.5 after phenylephrine (p less than 0.02); from 4.2 +/- 6.5 to 21.2 +/- 5.3 after dextran (p less than 0.02)). Conversely, dobutamine reduced T2 from 4.4 +/- 5.9 to -2.5 +/- 6.5 (p less than 0.05). Thus, during load-active interventions aortic pressure increases for a longer T2 time although forward flow is decreasing, as a result of higher aortic elastic recoil during ejection. Conversely, beta 1-adrenergic stimulation significantly shortens T2. Dynamic pressure-flow relationship is thus continuously changing during ejection. T2 seems to be inversely related to the efficiency of left ventricular ejection dynamics.
Morales, Maria-Aurora; Neglia, Danilo; L'Abbate, Antonio
2008-08-01
Myocardial blood flow during pharmacological vasodilatation is depressed in patients with idiopathic dilated cardiomyopathy even the in absence of overt heart failure; the extent of myocardial blood flow abnormalities is not predictable by left ventricular ejection fraction (LVEF) and diastolic dimensions. To assess whether myocardial blood flow impairment in idiopathic dilated cardiomyopathy without overt heart failure can be related to Doppler-derived dP/dt and to echocardiographically determined left ventricular end systolic stress - which is linked to myocardial blood flow reserve in advanced disease. Twenty-six patients, New York Heart Association Class I-II, (LVEF 37.4 +/- 1.4%, left ventricular diastolic dimensions 62.6 +/- 0.9 mm) underwent resting/dipyridamole [13N]NH3 flow positron emission tomography and an ultrasonic study. Regional myocardial blood flow values (ml/min per g) were computed from positron emission tomography data in 13 left ventricular (LV) myocardial regions and averaged to provide mean myocardial blood flow and myocardial blood flow reserve, defined as dipyridamole/resting mean myocardial blood flow ratio. Resting myocardial blood flow was 0.686 +/- 0.045, dipyridamole myocardial blood flow 1.39 +/- 0.15 and myocardial blood flow reserve 2.12 +/- 0.2, lower than in controls (P < 0.01). The ratio dP/dt was directly related to dipyridamole myocardial blood flow and myocardial blood flow reserve (r = 0.552 and 0.703, P < 0.005 and P < 0.0001); no relation was found between myocardial blood flow and LVEF left ventricular diastolic dimensions, and left ventricular end systolic stress. In idiopathic dilated cardiomyopathy patients without overt heart failure, the extent of myocardial blood flow reserve impairment is related to dP/dt but not to more classical indices of left ventricular function.
Kosaka, Ryo; Fukuda, Kyohei; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi
2013-01-01
In order to monitor the condition of a patient using a left ventricular assist system (LVAS), blood flow should be measured. However, the reliable determination of blood-flow rate has not been established. The purpose of the present study is to develop a noninvasive blood-flow meter using a curved cannula with zero compensation for an axial flow blood pump. The flow meter uses the centrifugal force generated by the flow rate in the curved cannula. Two strain gauges served as sensors. The first gauges were attached to the curved area to measure static pressure and centrifugal force, and the second gauges were attached to straight area to measure static pressure. The flow rate was determined by the differences in output from the two gauges. The zero compensation was constructed based on the consideration that the flow rate could be estimated during the initial driving condition and the ventricular suction condition without using the flow meter. A mock circulation loop was constructed in order to evaluate the measurement performance of the developed flow meter with zero compensation. As a result, the zero compensation worked effectively for the initial calibration and the zero-drift of the measured flow rate. We confirmed that the developed flow meter using a curved cannula with zero compensation was able to accurately measure the flow rate continuously and noninvasively.
Development of an implantable ventricular assist system.
Macris, M P; Parnis, S M; Frazier, O H; Fuqua, J M; Jarvik, R K
1997-02-01
This study describes the present state of progress in the development of the Jarvik 2000 ventricular assist system. Designed for implantation in the human thorax, the system consists of a small (25 cm3, 90 g) intraventricular axial-flow blood pump that transmits power and data via internal electronics and a transcutaneous energy transfer system. The pump is powered by portable internal and external polymer lithium ion batteries. The only moving part, the pump rotor, contains a permanent magnet of a brushless direct-current motor that mounts an axial-flow impeller and partial magnetic thrust support, with blood-immersed radial and thrust bearings. The motor uses a redundant coil and electric lead design, which permits continued operation in case of wire breakage. Seven calves have been supported for an average of 107 days (range, 40 to 162 days) with prototypes of the Jarvik 2000 ventricular assist system. No physiologic complications have occurred. When its user is at rest, the pump produces flows of 5 to 6 L/min with a decreased arterial pulse contour. Renal and hepatic functions have remained normal throughout the duration of all studies. Mean plasma free hemoglobin levels ranged from 4.3 to 11.4 mg/dL (mean, 6.3 mg/dL) for each study. Pathologic analyses of the heart and kidneys revealed no damage related to the device. These studies indicate that the Jarvik 2000 ventricular assist system is feasible in animals and holds promise for long-term support of patients.
Acute microcirculatory response to nicotine in frog web.
Horimoto, M; Koyama, T
1982-01-01
Acute effects of nicotine (NC) on the microcirculation of frog webs were studied by measuring the blood flow velocity in arterioles, and by determining the diameter of both arterioles and venules. Simultaneous recordings of the ventricular pressure and heart rate were obtained in order to compute the vascular resistance and to interpret the changes in microcirculation. The web of right hindlimb was immersed in a solution of NC (2.6 to 3.4 mg/ml) for 4 min. Blood flow velocity in web arterioles of left hindlimb was measured by means of a laser Doppler microscope. Internal diameters of web microvessels were determined using a micrometer on the ocular lens of the microscope. Mean flow velocity (MV) and pulsatile amplitude (PA) were calculated from the pulsatile flow-velocity contour for each vessel. Both MV and PA were increased after the immersion of the web in NC solution. Although the magnitude of the increment in MV was proportional to that in ventricular pressure, the vasodilation of both arterioles and venules and the flow rate in arterioles higher than the initial state continued even after the ventricular pressure had returned to the initial control value. Calculation of the relative change in vascular resistance in web arterioles following NC administration suggested a vasodilator response to NC. Furthermore, our results indicate that sufficient NC can be absorbed across the web epithelium to produce a systemic vascular response when the concentration of NC in the bathing solution is 2.6 mg/ml.
Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.
Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N
1993-01-01
There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)
Management of pump thrombosis in patients with left ventricular assist devices.
Stulak, John M; Sharma, Shashank; Maltais, Simon
2015-04-01
The gradual evolution of left ventricular assist device (LVAD) therapy has resulted in a durable option for patients as either a bridge to transplantation (BTT) or a destination therapy (DT). Outcomes with current continuous-flow devices continue to demonstrate significant patient benefit, not only in enhanced survival but also in improved functional capacity and quality of life. While the lessening of adverse events through time has resulted in more widespread adoption of this therapy, there continues to be unintended consequences, including, most notably, infection, bleeding, and thrombosis. Beginning in 2011, centers and collaborative groups began to observe a significant increase in the incidence of pump thrombosis with the HeartMate II LVAD (Thoratec Corp., Pleasanton, CA, USA). However, this clinical scourge is not limited to the HeartMate II, as the HeartWare Ventricular Assist System (HVAD; HeartWare Inc., Framingham, MA, USA) has also had these same issues, which led to pump modifications and the appreciation of more strict control of blood pressure and anticoagulation with this pump design. We review the current status of the field of mechanical circulatory support in its approach to diagnosis, management, and prevention of LVAD pump thrombosis.
Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J
2014-01-01
Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP < 60, 60-70, 70-80, 80-90, and ≥90), the correlation of CO with LVAD flow differed (R = 0.42, 0.67, 0.48, 0.32, 0.32, respectively). Indicating better correlation when mean blood pressure is 60 to 70 mm Hg. Left ventricular assist device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.
Bovendeerd, Peter H M; Borsje, Petra; Arts, Theo; van De Vosse, Frans N
2006-12-01
The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity.
Wang, Yu; Koenig, Steven C; Slaughter, Mark S; Giridharan, Guruprasad A
2015-01-01
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R
2014-01-01
Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all <10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.
Drews, Thorsten; Potapov, Evgenij; Weng, Yugo; Pasic, Miralem; Hetzer, Roland
2014-01-01
Objective This manuscript summarizes our surgical experience with the implantation of recent continuous-flow left ventricular assist devices (LVADs), with special emphasis on the HeartWare HVAD pump. Methods The HeartWare HVAD is, in our experience currently implanted in four different techniques: (I) “Classical” LVAD implantation with heart-lung machine and median sternotomy; (II) “Minimally-invasive” implantation without sternotomy and without heart-lung machine; (III) “Lateral implantation” to the descending aorta; (IV) Using two continuous-flow LVADs for implantable biventricular support. Results Five-hundred and four HeartWare HVADs have been implanted using the described techniques in our institution up to now. Conclusions The HeartWare HVAD is a versatile device. It has been found to be eminently suited to these four different modes of implantation. PMID:25452906
Phan, Kevin; Huo, Ya Ruth; Zhao, Dong Fang; Yan, Tristan D; Tchantchaleishvili, Vakhtang
2016-01-01
Several studies have reported that a portion of patients who exhibit cardiac recovery during left ventricular assist device (LVAD) support can have their device explanted with reasonable long-term survival. The aim of this systematic review is to assess the survival and cardiac function in patients with explanted LVADs from the current literature. Electronic search was performed to identify all studies in English literature assessing LVAD explantation. All identified articles were systematically assessed using the inclusion and exclusion criteria. Selected studies were subjected to quantitative assessment. From 5 electronic databases, 11 studies (213 patients) were included. Pooled mean perioperative mortality rate of those explanted was 9.2% (95% CI, 5.0-14.5%; I = 0). Pooled mean late mortality rate was 15% (95% CI, 9.0-22.1%; I = 31%). The pooled 1, 5, and 10 year survival postexplant was 91, 76, and 65.7%, respectively. Pooled postweaning freedom from heart failure (HF) recurrence reached 81.3%. Subset analysis demonstrated that patients explanted from a continuous-flow LVAD versus pulsatile LVAD had a lower rate of HF recurrence (6.6 vs. 28.3%, p = 0.03) and LVAD reimplantation (7.5 vs. 37%, p = 0.001). Before LVAD explantation, overall mean left ventricular ejection fraction (LVEF) was 49%. Weighted pooled early and late postexplantation mean LVEF was 47.3 and 41.2%, respectively. Late postexplantation LVEF was significantly higher in the continuous-flow versus pulsatile LVAD subgroup (41.5 vs. 24%, p = 0.001). This review shows encouraging safety and 10 year survival outcomes after explantation of LVADs in carefully selected patients, with rates better than expected after a heart transplant. Recovery of the native heart is the most desirable clinical outcome in patients supported with LVADs and should be actively sought.
Pennell, Thomas; Yi, Juneyoung L; Kaufman, Bruce A; Krishnamurthy, Satish
2016-03-01
OBJECT Mechanical failure-which is the primary cause of CSF shunt malfunction-is not readily diagnosed, and the specific reasons for mechanical failure are not easily discerned. Prior attempts to measure CSF flow noninvasively have lacked the ability to either quantitatively or qualitatively obtain data. To address these needs, this preliminary study evaluates an ultrasonic transit time flow sensor in pediatric and adult patients with external ventricular drains (EVDs). One goal was to confirm the stated accuracy of the sensor in a clinical setting. A second goal was to observe the sensor's capability to record real-time continuous CSF flow. The final goal was to observe recordings during instances of flow blockage or lack of flow in order to determine the sensor's ability to identify these changes. METHODS A total of 5 pediatric and 11 adult patients who had received EVDs for the treatment of hydrocephalus were studied in a hospital setting. The primary EVD was connected to a secondary study EVD that contained a fluid-filled pressure transducer and an in-line transit time flow sensor. Comparisons were made between the weight of the drainage bag and the flow measured via the sensor in order to confirm its accuracy. Data from the pressure transducer and the flow sensor were recorded continuously at 100 Hz for a period of 24 hours by a data acquisition system, while the hourly CSF flow into the drip chamber was recorded manually. Changes in the patient's neurological status and their time points were noted. RESULTS The flow sensor demonstrated a proven accuracy of ± 15% or ± 2 ml/hr. The flow sensor allowed real-time continuous flow waveform data recordings. Dynamic analysis of CSF flow waveforms allowed the calculation of the pressure-volume index. Lastly, the sensor was able to diagnose a blocked catheter and distinguish between the blockage and lack of flow. CONCLUSIONS The Transonic flow sensor accurately measures CSF output within ± 15% or ± 2 ml/hr, diagnoses the blockage or lack of flow, and records real-time continuous flow data in patients with EVDs. Calculations of a wide variety of diagnostic parameters can be made from the waveform recordings, including resistance and compliance of the ventricular catheters and the compliance of the brain. The sensor's clinical applications may be of particular importance to the noninvasive diagnosis of shunt malfunctions with the development of an implantable device.
Real-time segmentation in 4D ultrasound with continuous max-flow
NASA Astrophysics Data System (ADS)
Rajchl, M.; Yuan, J.; Peters, T. M.
2012-02-01
We present a novel continuous Max-Flow based method to segment the inner left ventricular wall from 3D trans-esophageal echocardiography image sequences, which minimizes an energy functional encoding two Fisher-Tippett distributions and a geometrical constraint in form of a Euclidean distance map in a numerically efficient and accurate way. After initialization the method is fully automatic and is able to perform at up to 10Hz making it available for image-guided interventions. Results are shown on 4D TEE data sets from 18 patients with pathological cardiac conditions and the speed of the algorithm is assessed under a variety of conditions.
Miyamoto, Takuma; Karimov, Jamshid H; Fukamachi, Kiyotaka
2018-03-01
Continuous-flow (CF) left ventricular assist devices (LVADs) are widely used to treat end-stage heart failure. Despite substantial improvement in clinical results, numerous complications remain associated with this technology. Worsening renal function is one, associated with morbidity and mortality in patients supported by CF LVADs. The effects of CF LVAD support on renal function have been investigated since the mid-1990s by many research groups. Area covered: We review the current status of LVAD therapy, experimental results regarding the effects of types of flow generated by LVADs on renal function and pathology, changes in renal function after LVAD implant, the influence of renal function on outcomes, and risk factors for renal dysfunction post implant. This information was obtained through online databases and direct extraction of single studies. Expert commentary: Immediately after CF LVAD implantation, renal function improves temporarily as patients recover from the kidneys' previously low perfusion and congestive state. However, many studies have shown that this initially recovered renal function gradually declines during long-term CF LVAD support. Although it is known that CF LVAD support adversely affects renal function over the long term, just how it does has not yet been clearly defined in terms of clinical symptoms or signs.
Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.
Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J
2014-03-01
Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Borsje, Petra; Arts, Theo; van De Vosse, Frans N.
2006-01-01
The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity. PMID:17048105
The effects of hypoxemia on myocardial blood flow during exercise.
Paridon, S M; Bricker, J T; Dreyer, W J; Reardon, M; Smith, E O; Porter, C B; Michael, L; Fisher, D J
1989-03-01
We evaluated the adequacy of regional and transmural blood flow during exercise and rapid pacing after 1 wk of hypoxemia. Seven mature mongrel dogs were made hypoxemic (mean O2 saturation = 72.4%) by anastomosis of left pulmonary artery to left atrial appendage. Catheters were placed in the left atrium, right atrium, pulmonary artery, and aorta. Atrial and ventricular pacing wires were placed. An aortic flow probe was placed to measure cardiac output. Ten nonshunted dogs, similarly instrumented, served as controls. Recovery time was approximately 1 wk. Cardiac output, mean aortic pressure, and oxygen saturation were measured at rest, with ventricular pacing, atrial pacing, and with treadmill exercise. Ventricular and atrial pace and exercise were at a heart rate of 200. Right ventricular free wall, left ventricular free wall, and septal blood flow were measured with radionuclide-labeled microspheres. Cardiac output, left atrial blood pressure, and aortic blood pressure were similar between the two groups of dogs in all testing states. Myocardial blood flow was significantly higher in the right and left ventricular free wall in the hypoxemic animals during resting and exercise testing states. Myocardial oxygen delivery was similar between the two groups of animals. Pacing resulted in an increase in myocardial blood flow in the control animals but not the hypoxemic animals.(ABSTRACT TRUNCATED AT 250 WORDS)
B-type natriuretic peptide levels and continuous-flow left ventricular assist devices.
Sareyyupoglu, Basar; Boilson, Barry A; Durham, Lucian A; McGregor, Christopher G A; Daly, Richard C; Redfield, Margaret M; Edwards, Brooks S; Frantz, Robert P; Pereira, Naveen L; Park, Soon J
2010-01-01
We postulated that postoperative B-type natriuretic peptide (BNP) levels would be reflective of the degree of hemodynamic support rendered by various pump speeds settings (RPM) of continuous-flow left ventricular assist devices (LVADs). Twenty LVAD patients were evaluated prospectively (Jarvik 2000: n = 9, HeartMate II: n = 11). The mean age was 57.7 ± 14.9 years, and 14 were male. B-type natriuretic peptide levels were drawn while the patients were supported on LVADs at variable RPM settings. The RPM settings were correlated with the changes in BNP levels. Eleven patients underwent LVAD implantation for a lifelong support while the rest were as a bridge therapy to transplantation. Four patients required LVAD change out for various causes of pump failure. Postoperative BNP levels decreased dramatically with the initiation of LVAD support. The levels correlated inversely with the degree of hemodynamic support rendered at various RPM settings of the HeartMate II (p < 0.001). Overall, BNP levels decreased significantly in 2 days after RPM increase. We observed a significant inverse correlation between the postoperative BNP levels and the degree of LVAD support. The effective LVAD support seems to result in a marked reduction in BNP levels, and monitoring serial BNP levels may be helpful in managing patients supported on continuous LVAD.
Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J
2012-06-01
The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P < .001), worse right ventricular dysfunction (right ventricular end-diastolic area, 33.6 ± 6.2 mm vs 31.6 ± 8.5 mm; P = .05), higher mean right atrial pressure (17.4 ± 7.1 mm Hg vs 14.9 ± 5.1 mm Hg; P = .03), and a higher Kormos score (2.6 ± 2.1 vs 1.2 ± 1.4; P = .0008) preoperatively. One month after surgery, tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Guha, Ashrith; Nguyen, Duc; Cruz-Solbes, Ana S; Amione-Guerra, Javier; Schutt, Robert C; Bhimaraj, Arvind; Trachtenberg, Barry H; Park, Myung H; Graviss, Edward A; Gaber, Osama; Suarez, Erik; Montane, Eva; Torre-Amione, Guillermo; Estep, Jerry D
Patients bridged to transplant (BTT) with continuous-flow left ventricular assist devices (CF-LVADs) have increased in the past decade. Decision support tools for these patients are limited. We developed a risk score to estimate prognosis and guide decision-making. We included heart transplant recipients bridged with CF-LVADs from the United Network for Organ Sharing (UNOS) database and divided them into development (2,522 patients) and validation cohorts (1,681 patients). Univariate and multivariate Cox proportional hazards models were performed. Variables that independently predicted outcomes (age, African American race, recipient body mass index [BMI], intravenous [IV] antibiotic use, pretransplant dialysis, and total bilirubin) were assigned weight using linear transformation, and risk scores were derived. Patients were grouped by predicted posttransplant mortality: low risk (≤ 38 points), medium risk (38-41 points), and high risk (≥ 42 points). We performed Cox proportional hazards analysis on wait-listed CF-LVAD patients who were not transplanted. Score significantly discriminated survival among the groups in the development cohort (6.7, 12.9, 20.7; p = 0.001), validation cohort (6.4, 10.1, 13.6; p < 0.001), and ambulatory cohort (6.4, 11.5, 17.2; p < 0.001). We derived a left ventricular assist device (LVAD) BTT risk score that effectively identifies CF-LVAD patients who are at higher risk for worse outcomes after heart transplant. This score may help physicians weigh the risks of transplantation in patients with CF-LVAD.
Roszelle, Breigh N.; Deutsch, Steven; Manning, Keefe B.
2010-01-01
In order to aid the ongoing concern of limited organ availability for pediatric heart transplants, Penn State has continued development of a pulsatile Pediatric Ventricular Assist Device (PVAD). Initial studies of the PVAD observed an increase in thrombus formation due to differences in flow field physics when compared to adult sized devices, which included a higher degree of three-dimensionality. This unique flow field brings into question the use of 2D planar particle image velocimetry (PIV) as a flow visualization technique, however the small size and high curvature of the PVAD make other tools such as stereoscopic PIV impractical. In order to test the reliability of the 2D results, we perform a pseudo-3D PIV study using planes both parallel and normal to the diaphragm employing a mock circulatory loop containing a viscoelastic fluid that mimics 40% hematocrit blood. We find that while the third component of velocity is extremely helpful to a physical understanding of the flow, particularly of the diastolic jet and the development of a desired rotational pattern, the flow data taken parallel to the diaphragm is sufficient to describe the wall shear rates, a critical aspect to the study of thrombosis and design of such pumps. PMID:19936926
Left atrial booster function in valvular heart disease.
Heidenreich, F P; Shaver, J A; Thompson, M E; Leonard, J J
1970-09-01
This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flow for each cardiac cycle by transposition of the Gorlin formula. Left ventricular ejection time and left ventricular stroke work in aortic stenosis or left ventricular mean systolic pressure in mitral stenosis were also determined. Control observations were recorded during sequential A-V pacing with well-timed atrial systole. Cardiac cycles were then produced with no atrial contraction but undisturbed atrial reservoir function by intermittently interrupting the atrial pacing stimulus during sequential A-V pacing. This intervention significantly reduced valvular gradient, flow, left ventricular ejection time, and left ventricular mean systolic pressure or stroke work. Cardiac cycles were then produced with atrial booster action eliminated by instituting synchronous A-V pacing. The resultant simultaneous contraction of the atrium and ventricle not only eliminated effective atrial systole but also placed atrial systole during the normal period of atrial reservoir function. This also significantly reduced all the hemodynamic measurements. However, comparison of the magnitude of change from these two different pacing interventions showed no greater impairment of hemodynamic state when both booster pump action and reservoir function were impaired than when booster pump action alone was impaired. The study confirms the potential benefit of well placed atrial booster pump action in valvular heart disease in man.
Jeong, Daniel; Anagnostopoulos, Petros V; Roldan-Alzate, Alejandro; Srinivasan, Shardha; Schiebler, Mark L; Wieben, Oliver; François, Christopher J
2015-05-01
Ventricular kinetic energy measurements may provide a novel imaging biomarker of declining ventricular efficiency in patients with repaired tetralogy of Fallot. Our purpose was to assess differences in ventricular kinetic energy with 4-dimensional flow magnetic resonance imaging between patients with repaired tetralogy of Fallot and healthy volunteers. Cardiac magnetic resonance, including 4-dimensional flow magnetic resonance imaging, was performed at rest in 10 subjects with repaired tetralogy of Fallot and 9 healthy volunteers using clinical 1.5T and 3T magnetic resonance imaging scanners. Right and left ventricular kinetic energy (KERV and KELV), main pulmonary artery flow (QMPA), and aortic flow (QAO) were quantified using 4-dimensional flow magnetic resonance imaging data. Right and left ventricular size and function were measured using standard cardiac magnetic resonance techniques. Differences in peak systolic KERV and KELV in addition to the QMPA/KERV and QAO/KELV ratios between groups were assessed. Kinetic energy indices were compared with conventional cardiac magnetic resonance parameters. Peak systolic KERV and KELV were higher in patients with repaired tetralogy of Fallot (6.06 ± 2.27 mJ and 3.55 ± 2.12 mJ, respectively) than in healthy volunteers (5.47 ± 2.52 mJ and 2.48 ± 0.75 mJ, respectively), but were not statistically significant (P = .65 and P = .47, respectively). The QMPA/KERV and QAO/KELV ratios were lower in patients with repaired tetralogy of Fallot (7.53 ± 5.37 mL/[cycle mJ] and 9.65 ± 6.61 mL/[cycle mJ], respectively) than in healthy volunteers (19.33 ± 18.52 mL/[cycle mJ] and 35.98 ± 7.66 mL/[cycle mJ], respectively; P < .05). QMPA/KERV and QAO/KELV were weakly correlated to ventricular size and function. Greater ventricular kinetic energy is necessary to generate flow in the pulmonary and aortic circulations in repaired tetralogy of Fallot. Quantification of ventricular kinetic energy in patients with repaired tetralogy of Fallot is a new observation. Future studies are needed to determine whether changes in ventricular kinetic energy can provide earlier evidence of ventricular dysfunction and guide future medical and surgical interventions. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.
Pinney, Sean P
2015-10-01
Clinical outcomes for patients with advanced heart failure receiving left ventricular assist devices are driven by appropriate patient selection, refined surgical technique, and coordinated medical care. Perhaps even more important is innovative pump design. The introduction and widespread adoption of continuous-flow ventricular assist devices has led to a paradigm shift within the field of mechanical circulatory support, making the promise of lifetime device therapy closer to reality. The disruption caused by this new technology, on the one hand, produced meaningful improvements in patient survival and quality of life, but also introduced new clinical challenges, such as bleeding, pump thrombosis, and acquired valvular heart disease. Further evolution within this field will require financial investment to sustain innovation leading to a fully implantable, durable, and cost-effective pump for a larger segment of patients with advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Arakawa, Mamoru; Nishimura, Takashi; Takewa, Yoshiaki; Umeki, Akihide; Ando, Masahiko; Kishimoto, Yuichiro; Kishimoto, Satoru; Fujii, Yutaka; Date, Kazuma; Kyo, Shunei; Adachi, Hideo; Tatsumi, Eisuke
2016-06-01
We previously developed a novel control system for a continuous-flow left ventricular assist device (LVAD), the EVAHEART, and demonstrated that sufficient pulsatility can be created by increasing its rotational speed in the systolic phase (pulsatile mode) in a normal heart animal model. In the present study, we assessed this system in its reliability and ability to follow heart rate variability. We implanted an EVAHEART via left thoracotomy into five goats for the Study for Fixed Heart Rate with ventricular pacing at 80, 100, 120 and 140 beats/min and six goats for the Study for native heart rhythm. We tested three modes: the circuit clamp, the continuous mode and the pulsatile mode. In the pulsatile mode, rotational speed was increased during the initial 35 % of the RR interval by automatic control based on the electrocardiogram. Pulsatility was evaluated by pulse pressure and dP/dt max of aortic pressure. As a result, comparing the pulsatile mode with the continuous mode, the pulse pressure was 28.5 ± 5.7 vs. 20.3 ± 7.9 mmHg, mean dP/dt max was 775.0 ± 230.5 vs 442.4 ± 184.7 mmHg/s at 80 bpm in the study for fixed heart rate, respectively (P < 0.05). The system successfully determined the heart rate to be 94.6 % in native heart rhythm. Furthermore, pulse pressure was 41.5 ± 7.9 vs. 27.8 ± 5.6 mmHg, mean dP/dt max was 716.2 ± 133.9 vs 405.2 ± 86.0 mmHg/s, respectively (P < 0.01). In conclusion, our newly developed the pulsatile mode for continuous-flow LVADs reliably provided physiological pulsatility with following heart rate variability.
Laser restoration of flow in occluded ventricular shunts for pediatric neurosurgery
NASA Astrophysics Data System (ADS)
Christens-Barry, William A.; Guarnieri, Michael; Carson, Benjamin S.
1998-01-01
We have investigated the use of short pulses of infrared ((lambda) equals 2.09 micrometers ) light from a Ho:YAG laser to photofragment occlusions and restore flow in ventricular shunts, which provide the sole means of maintaining proper intracranial pressure in hydrocephalus patients. These experiments employed model tissues, a polymeric model compound, and patient explants in order to determine appropriate pulse energies and delivery rates for removal of occlusions material. Laser energy doses and rates of occlusion removal were established for these materials. Laser energy doses that do not damage the shunt device or surrounding tissue were identified. Optical fibers (25 ga. or smaller) can be introduced through the dome of current shunt devices and threaded to the occlusion site. Clinical application will require the continued development of an introducer tool for the transcutaneous insertion of the optical fiber into the shunt device and irrigation techniques for removing the occlusion detritus generated by photofragmentation treatment. Using this approach, a minimally invasive and benign procedure for in situ restoration of flow in occluded neurological implant devices becomes possible.
Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J
2003-09-01
We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.
Experimental study on the effect of an artificial cardiac valve on the left ventricular flow
NASA Astrophysics Data System (ADS)
Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun
2017-09-01
The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.
MacLea, H B; Boon, J A; Bright, J M
2013-01-01
Hypertrophic cardiomyopathy (HCM) is heterogeneous in both people and cats, with variability in the distribution of hypertrophy, hemodynamic characteristics, and Doppler echocardiographic findings. To document the Doppler echocardiographic characteristics of midventricular obstruction in some cats with HCM. Eight cats with hypertrophic cardiomyopathy. Retrospective case series. The medical records of cats presenting to the cardiology service at Colorado State University between February 2009 and January 2012 were reviewed. All cats had a physical examination; Doppler systolic blood pressure measurement; and transthoracic two-dimensional (2D), M-mode, and Doppler echocardiography were performed. A more thorough evaluation of the echocardiographic images and measurements was performed. Cats included in this study had echocardiograms of adequate quality to confirm the diagnosis of midventricular obstruction by documentation of left midventricular concentric hypertrophy; a midventricular turbulent Doppler color flow pattern; and high velocity, late-peaking flow at the area of turbulence. Cats with evidence of systemic hypertension defined as a systolic Doppler blood pressure of greater than 170 mmHg were excluded. All 8 cats had left ventricular hypertrophy at the level of the papillary muscles; left, midventricular hypertrophy; and in 4/8 cats there was apical hypertrophy or basilar hypertrophy of the interventricular septum. Color flow Doppler revealed turbulent flow in 8/8 cats and spectral Doppler (continuous and pulsed wave) revealed increased flow velocities and late-peaking flow profiles at the level of the left midventricle. Two of 8 cats had a bifid midventricular flow profile in which there was a midsystolic decline in left ventricular velocities with elevated velocities extending into early diastole. The peak left ventricular outflow velocity in all 8 cats was normal. A variant of HCM characterized by hypertrophy at the level of the papillary muscles with midventricular obstruction is present in some cats. Recognition of this variant of feline HCM allows identification of HCM in cats with murmurs where the more classic features of HCM are not present. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Right Ventricular Perfusion: Physiology and Clinical Implications.
Crystal, George J; Pagel, Paul S
2018-01-01
Regulation of blood flow to the right ventricle differs significantly from that to the left ventricle. The right ventricle develops a lower systolic pressure than the left ventricle, resulting in reduced extravascular compressive forces and myocardial oxygen demand. Right ventricular perfusion has eight major characteristics that distinguish it from left ventricular perfusion: (1) appreciable perfusion throughout the entire cardiac cycle; (2) reduced myocardial oxygen uptake, blood flow, and oxygen extraction; (3) an oxygen extraction reserve that can be recruited to at least partially offset a reduction in coronary blood flow; (4) less effective pressure-flow autoregulation; (5) the ability to downregulate its metabolic demand during coronary hypoperfusion and thereby maintain contractile function and energy stores; (6) a transmurally uniform reduction in myocardial perfusion in the presence of a hemodynamically significant epicardial coronary stenosis; (7) extensive collateral connections from the left coronary circulation; and (8) possible retrograde perfusion from the right ventricular cavity through the Thebesian veins. These differences promote the maintenance of right ventricular oxygen supply-demand balance and provide relative resistance to ischemia-induced contractile dysfunction and infarction, but they may be compromised during acute or chronic increases in right ventricle afterload resulting from pulmonary arterial hypertension. Contractile function of the thin-walled right ventricle is exquisitely sensitive to afterload. Acute increases in pulmonary arterial pressure reduce right ventricular stroke volume and, if sufficiently large and prolonged, result in right ventricular failure. Right ventricular ischemia plays a prominent role in these effects. The risk of right ventricular ischemia is also heightened during chronic elevations in right ventricular afterload because microvascular growth fails to match myocyte hypertrophy and because microvascular dysfunction is present. The right coronary circulation is more sensitive than the left to α-adrenergic-mediated constriction, which may contribute to its greater propensity for coronary vasospasm. This characteristic of the right coronary circulation may increase its vulnerability to coronary vasoconstriction and impaired right ventricular perfusion during administration of α-adrenergic receptor agonists.
Effect of the mitral valve on diastolic flow patterns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Jung Hee; Vedula, Vijay; Mittal, Rajat, E-mail: mittal@jhu.edu
2014-12-15
The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diodemore » type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed.« less
Design and numeric evaluation of a novel axial-flow left ventricular assist device.
Toptop, Koral; Kadipasaoglu, Kamuran A
2013-01-01
Virtual design characteristics and performance of the first Turkish axial-flow left ventricular assist device (LVAD) are presented, with emphasis on rotor geometry. The patented rotor design includes a central flow channel carved inside the main block, which carries permanent magnets. A concentric rotor-stator gap minimizes the distance between respective magnets, improving electromagnetic efficiency and creating a second blood pathway. Dual sets of three helical blades, placed on the shaft and external surface of the rotor block, ensure unidirectionality. Hemodynamic performance was tested with computational fluid dynamics (CFD); and rotor-blade geometry was optimized, to maximize overall efficiency d and minimize backflow and wall shear stresses. For a shaft radius of 4.5 mm, rotor blade height of 2.5 mm, and blade inlet and exit metal angles of 67° and 32°, pump operation at the nominal head-flow combination (5 L/min and 100.4 mm Hg) was achieved at a rotor speed of 10,313 rpm. At the nominal point, backflow as percent of total flow was 7.29 and 29.87% at rotor inlet and exit, respectively; overall hydraulic efficiency reached 21.59%; and maximum area-averaged shroud shear was 520 Pa. Overall efficiency peaked at 24.07% for a pump flow of 6.90 L/min, and averaged at 22.57% within the flow range of 4-8 L/min. We concluded that the design satisfies initial rotor design criteria, and that continued studies with diffuser optimization and transient flow analysis are warranted.
Future Prospects for the Total Artificial Heart.
Sunagawa, Gengo; Horvath, David J; Karimov, Jamshid H; Moazami, Nader; Fukamachi, Kiyotaka
2016-01-01
A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.
Zhu, Shidong; Luo, Lin; Yang, Bibo; Li, Xinghui; Wang, Xiaohao
2017-12-01
Ventricular assist devices (LVADs) are increasingly recognized for supporting blood circulation in heart failure patients who are non-transplant eligible. Because of its volume, the traditional pulsatile device is not easy to implant intracorporeally. Continuous flow LVADs (CF-LVADs) reduce arterial pulsatility and only offer continuous flow, which is different from physiological flow, and may cause long-term complications in the cardiovascular system. The aim of this study was to design a new pulsatile assist device that overcomes this disadvantage, and to test this device in the cardiovascular system. Firstly, the input and output characteristics of the new device were tested in a simple cardiovascular mock system. A detailed mathematical model was established by fitting the experimental data. Secondly, the model was tested in four pathological cases, and was simulated and coupled with a fifth-order cardiovascular system and a new device model using Matlab software. Using assistance of the new device, we demonstrated that the left ventricle pressure, aortic pressure, and aortic flow of heart failure patients improved to the levels of a healthy individual. Especially, in state IV level heart failure patients, the systolic blood pressure increased from 81.34 mmHg to 132.1 mmHg, whereas the diastolic blood pressure increased from 54.28 mmHg to 78.7 mmHg. Cardiac output increased from 3.21 L/min to 5.16 L/min. The newly-developed assist device not only provided a physiological flow that was similar to healthy individuals, but also effectively improved the ability of the pathological ventricular volume. Finally, the effects of the new device on other hemodynamic parameters are discussed.
Diastolic heart failure associated with hemangiosarcoma infiltrating left ventricular walls in a dog
Osuga, Tatsuyuki; Nakamura, Kensuke; Morita, Tomoya; Kagawa, Yumiko; Ohta, Hiroshi; Takiguchi, Mitsuyoshi
2017-01-01
A 9-year-old Shetland sheepdog was diagnosed with cardiogenic pulmonary edema. Echocardiography revealed focally thickened left ventricular free wall and interventricular septum and left atrial dilation. Left ventricular systolic function was preserved. Doppler echocardiography of transmitral flow indicated restrictive left ventricular filling. Cardiac histopathology demonstrated hemangiosarcoma infiltrating the left ventricular walls. PMID:29089652
Osuga, Tatsuyuki; Nakamura, Kensuke; Morita, Tomoya; Kagawa, Yumiko; Ohta, Hiroshi; Takiguchi, Mitsuyoshi
2017-11-01
A 9-year-old Shetland sheepdog was diagnosed with cardiogenic pulmonary edema. Echocardiography revealed focally thickened left ventricular free wall and interventricular septum and left atrial dilation. Left ventricular systolic function was preserved. Doppler echocardiography of transmitral flow indicated restrictive left ventricular filling. Cardiac histopathology demonstrated hemangiosarcoma infiltrating the left ventricular walls.
Baranowski, Jacek; Delshad, Baz; Ahn, Henrik
2017-01-01
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelectromechanical system pressure sensor (Titan, ISS Inc., Ypsilanti, MI) was placed in the left atrium in four patients at the time of LVAD implantation. Titan sensor LAP was measured in all four patients on the intensive care unit and in three patients at home. Ramped speed tests were performed using LAP and echocardiography in three patients. The left ventricular end-diastolic diameter (cm), flow (L/min), power consumption (W), and blood pressure (mm Hg) were measured at each step. Measurements were performed over 36, 84, 137, and 180 days, respectively. The three discharged patients had equipment at home and were able to perform daily recordings. There were significant correlations between sensor pressure and pump speed, LV and LA size and pulmonary capillary wedge pressure, respectively (r = 0.92–0.99, p < 0.05). There was no device failure, and there were no adverse consequences of its use. PMID:27676410
Impact of Pulmonary Flow Study Pressure on Outcomes After One-Stage Unifocalization.
Trezzi, Matteo; Albanese, Sonia B; Albano, Antonio; Rinelli, Gabriele; D'Anna, Carolina; Polito, Angelo; Cetrano, Enrico; Carotti, Adriano
2017-12-01
The purpose of this study was to evaluate the accuracy of the pulmonary flow study in (1) predicting the feasibility of concomitant intracardiac repair after one-stage unifocalization; and in (2) predicting long-term survival and the onset of right ventricular dysfunction after surgery. Between October 1996 and July 2015, a flow study was obtained in 95 patients undergoing complete one-stage unifocalization for pulmonary atresia with ventricular septal defect and major aortopulmonary collaterals. The ability to achieve 100% flow (approximately 2.5 L · min -1 · m -2 ) into the pulmonary bed at a mean pressure of 30 mm Hg or less was utilized as an indicator for acceptability of ventricular septal defect closure. Overall survival was 78% ± 6% at 15 years. Sixty-four patients underwent successful one-stage intracardiac repair. The flow study accurately predicted suitability for VSD closure (area under the curve = 0.855). After one-stage ventricular septal defect closure, no difference in survival was observed after stratification according to flow study pressures (25 mm Hg or less versus greater than 25 mm Hg, log rank p = 0.20). At a median follow-up of 7 years, no association was found between flow study pressure and the onset of right ventricular dysfunction (p = 0.21). Overall, the inability to achieve final intracardiac repair was a strong predictor of death (hazard ratio 9.14, 95% confidence interval: 1.98 to 42.07, p < 0.0001). Suitability for ventricular septal defect closure is reliably defined by the flow study with a cutoff of 30 mm Hg. Flow study pressure values do not affect long-term outcomes. The ability to obtain intracardiac repair (in either one or more stages) is the strongest predictor of survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Nguyen, Yen Ngoc; Ismail, Munirah; Kabinejadian, Foad; Tay, Edgar Lik Wui; Leo, Hwa Liang
2018-04-01
Intra-ventricular flow dynamics has recently emerged as an important evaluation and diagnosis tool in different cardiovascular conditions. The formation of vortex pattern during the cardiac cycle has been suggested to play important epigenetic and energy-modulation roles in cardiac remodelling, adaptations and mal-adaptations. In this new perspective, flow alterations due to different cardiovascular procedures can affect the long-term outcome of those procedures. Especially, repairs and replacements performed on atrioventricular valves are likely to exert direct impact on intra-ventricular flow pattern. In this review, current consensus around the roles of vortex dynamics in cardiac function is discussed. An overview of physiological vortex patterns found in healthy left and right ventricles as well as post-operative ventricular flow phenomenon owing to different atrioventricular valvular procedures are reviewed, followed by the summary of different vortex identification schemes used to characterise intraventricular flow. This paper also emphasises on future research directions towards a comprehensive understanding of intra-cardiac flow and its clinical relevance. The knowledge could encourage more effective pre-operative planning and better outcomes for current clinical practices. Copyright © 2018. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovetz, H.S.; Shaffer, F.; Schaub, R.
This paper discusses a series of experiments to visualize and measure flow fields in the Novacor left ventricular assist system (LVAS). The experiments utilize a multiple exposure, optical imaging technique called fluorescent image tracking velocimetry (FITV) to hack the motion of small, neutrally-buoyant particles in a flowing fluid.
Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A
2016-09-01
Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The tricuspid annulus had a complex 3D saddle-shaped geometry that was unaffected during experimental conditions. In healthy sheep hearts, left ventricular unloading increased septal-free wall RV diameter and reduced the length of the septal annulus, without altering the motion or geometry of the tricuspid annulus. Acute left ventricular unloading alone in healthy sheep was not sufficient to significantly perturb tricuspid annular dynamics and result in tricuspid insufficiency. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Pediatric experience with the VentrAssist LVAD.
Ruygrok, Peter N; Esmore, Don S; Alison, Peter M; Finucane, Kirsten A; McGuinness, Shay P; McGeorge, Alastair D; Negri, Justin; Jones, Kylie; Gibbs, Helen C
2008-08-01
The purpose of this study is to describe the first experience of implanting a new left ventricular assist device in pediatric patients with end-stage heart failure. In two recent prospective, international, multicenter clinical trials, three children (aged = 16 years) were implanted successfully with the VentrAssist (Ventracor Limited, Chatswood, Australia), a relatively small, novel, continuous flow, third-generation left ventricular assist device. Despite the patients' disease severity (each child was in extremis at the time of implantation), VentrAssist (Ventracor Limited) implantation enabled each patient to be discharged home from the hospital. All patients survived for more than 1 year. One patient was successfully transplanted and another was bridged to an adequate degree of recovery; unfortunately, the third patient died on postoperative day 375 while waiting for a suitable donor heart. Consistent with the complications associated with left ventricular assist devices in adults, the main complications in these pediatric patients were infection and thromboembolism. The VentrAssist may provide a major advancement in the management of larger children and adolescents with end-stage heart failure.
Allaire, P; Hilton, E; Baloh, M; Maslen, E; Bearnson, G; Noh, D; Khanwilkar, P; Olsen, D
1998-06-01
A new centrifugal continuous flow ventricular assist device, the CFVAD III, which is fully magnetic bearing suspended, has been developed. It has only one moving part (the impeller), has no contact (magnetic suspension), is compact, and has minimal heating. A centrifugal impeller of 2 inch outer diameter is driven by a permanent magnet brushless DC motor. This paper discusses the design, construction, testing, and performance of the magnetic bearings in the unit. The magnetic suspension consists of an inlet side magnetic bearing and an outlet side magnetic bearing, each divided into 8 pole segments to control axial and radial displacements as well as angular displacements. The magnetic actuators are composed of several different materials to minimize size and weight while having sufficient load capacity to support the forces on the impeller. Flux levels in the range of 0.1 T are employed in the magnetic bearings. Self sensing electronic circuits (without physical sensors) are employed to determine the impellar position and provide the feedback control signal needed for the magnetic bearing control loops. The sensors provide position sensitivity of approximately 0.025 mm. A decentralized 5 axis controller has been developed using modal control techniques. Proportional integral derivative controls are used for each axis to levitate the magnetically supported impeller.
Long-Term Survival in Patients Receiving a Continuous-Flow Left Ventricular Assist Device.
Gosev, Igor; Kiernan, Michael S; Eckman, Peter; Soleimani, Behzad; Kilic, Ahmet; Uriel, Nir; Rich, Jonathan D; Katz, Jason N; Cowger, Jennifer; Lima, Brian; McGurk, Siobhan; Brisco-Bacik, Meredith A; Lee, Sanjin; Joseph, Susan M; Patel, Chetan B
2018-03-01
Long-term survivors after implantation of left ventricular assist devices (LVADs) are increasing in prevalence. We describe the characteristics and outcomes in patients surviving longer than 4 years on LVAD support. We performed a multicenter, retrospective analysis of patients surviving at least 4 years on continuous-flow LVAD (CF-LVAD) support with a HeartMate II at centers participating in the Evolving Mechanical support Research Group. Between 2005 and 2010, 156 long-term survivors were identified with a mean survival of 7.1 years (95% confidence interval: 6.7 to 7.5 years). The mean age was 58.2 ± 15.2 years and 30.1% were women. Readmission rate was low at 1.1 events per patient per year with the most common reasons leading to readmission being infection (0.10 readmissions per patient per year) and gastrointestinal bleeding (0.07 readmissions per patient per year). Two years after implantation, 97% of patients were either New York Heart Association functional class I or II, with 92% at 4 years. Patients surviving 4 years on CF-LVAD support can anticipate ongoing long-term survival with sustained improvements in functionality and low rates of rehospitalization. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A computational fluid dynamics simulation framework for ventricular catheter design optimization.
Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A
2017-11-10
OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.
Kirklin, James K.; Naftel, David C.; Pagani, Francis D.; Kormos, Robert L.; Stevenson, Lynne; Miller, Marissa; Young, James B.
2012-01-01
Objective(s) Average two-year survival following cardiac transplantation is approximately 80%. The evolution and subsequent approval of larger pulsatile and, more recently, continuous flow mechanical circulatory support (MCS) technology for destination therapy (DT) offers the potential for triage of some patients awaiting cardiac transplantation to DT. Methods The National Heart, Lung and Blood Institute Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) is a national multi-institutional study of chronic mechanical circulatory support. Between June 2006 and December 2011, 127 pulsatile and 1160 continuous flow pumps (24% of total primary LVADs) carried an initial strategy of DT therapy. Results By multivariable analysis, risk factors (p<0.05) for mortality following DT included older age, larger body mass index, history of cancer, history of cardiac surgery, INTERMACS level I (cardiogenic shock), dialysis, increased BUN, use of a pulsatile flow device and use of a RVAD. Among continuous flow LVAD patients who were not in cardiogenic shock, a particularly favorable survival was associated with no cancer, patients not in cardiogenic shock, and BUN < 50, resulting in one and two year survival of 88 and 80%. Conclusions 1) Evolution from pulsatile to continuous flow technology has dramatically improved one and two year survival; 2) Destination Therapy is not appropriate for patients with rapid hemodynamic deterioration; or severe right ventricular failure 4) Important subsets of continuous flow DT patients now enjoy survival which is competitive with heart transplantation out to about two years. PMID:22795459
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.
Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson
2018-05-10
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
Suzuki, Gen; Weil, Brian R.; Leiker, Merced M.; Ribbeck, Amanda E.; Young, Rebeccah F.; Cimato, Thomas R.; Canty, John M.
2014-01-01
Background Cardiosphere-derived cells (CDCs) improve ventricular function and reduce fibrotic volume when administered via an infarct-related artery using the “stop-flow” technique. Unfortunately, myocyte loss and dysfunction occur globally in many patients with ischemic and non-ischemic cardiomyopathy, necessitating an approach to distribute CDCs throughout the entire heart. We therefore determined whether global intracoronary infusion of CDCs under continuous flow improves contractile function and stimulates new myocyte formation. Methods and Results Swine with hibernating myocardium from a chronic LAD occlusion were studied 3-months after instrumentation (n = 25). CDCs isolated from myocardial biopsies were infused into each major coronary artery (∼33×106 icCDCs). Global icCDC infusion was safe and while ∼3% of injected CDCs were retained, they did not affect ventricular function or myocyte proliferation in normal animals. In contrast, four-weeks after icCDCs were administered to animals with hibernating myocardium, %LADWT increased from 23±6 to 51±5% (p<0.01). In diseased hearts, myocyte proliferation (phospho-histone-H3) increased in hibernating and remote regions with a concomitant increase in myocyte nuclear density. These effects were accompanied by reductions in myocyte diameter consistent with new myocyte formation. Only rare myocytes arose from sex-mismatched donor CDCs. Conclusions Global icCDC infusion under continuous flow is feasible and improves contractile function, regresses myocyte cellular hypertrophy and increases myocyte proliferation in diseased but not normal hearts. New myocytes arising via differentiation of injected cells are rare, implicating stimulation of endogenous myocyte regeneration as the primary mechanism of repair. PMID:25402428
Development of an Inlet Pressure Sensor for Control in a Left Ventricular Assist Device
Fritz, Bryan; Cysyk, Joshua; Newswanger, Ray; Weiss, William; Rosenberg, Gerson
2010-01-01
A Tesla type continuous flow left ventricular assist device (VAD) has been designed by Penn State and Advanced Bionics, Inc. (ABI). When a continuous flow device is employed, care must be taken to limit low pressures in the ventricle that can produce an obstruction to the inlet cannula or trigger arrhythmias. Design of an inexpensive, semi-conductor strain gage inlet pressure sensor to detect suction has been completed. The research and design analysis included finite element modeling of the sensing region. Sensitivity, step-response, temperature dependence and hysteresis tests have been performed on prototype units. All sensors were able to withstand the maximum expected strain of 82 μin/in at 500 mmHg internal pressure. Average sensitivity was 0.52 ±0.24 μV/mmHg with 0.5 V excitation (n=5 units). Step response time for a 0 to 90 mmHg step change averaged 22 milliseconds. Hysteresis was measured by applying and holding 75mmHg internal pressure for 4 hours, followed by a zero pressure measurement, and ranged from -15 mmHg to 4.1 mmHg (n=3 units). Offset drift varied between 180 and -140 mmHg over a four week period. (n=2 units). Span temperature sensitivity ranged from 18 to -21 μV/°C (n=5 units). Gain temperature sensitivity ranged from -7.4 to 4.9 μV/°C (n=5 units). With the inherent drift, it is currently not possible to use the transducer to measure actual pressures, but it can easily be used to measure pressure changes throughout the cardiac cycle. This signal can then be used in the control system to avoid ventricular suction events. PMID:20335797
Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study.
Radovancevic, Branislav; Gregoric, Igor D; Tamez, Daniel; Vrtovec, Bojan; Tuzun, Egemen; Chee, Hyun Keun; Moore, Sheila; Jarvik, Robert K; Frazier, O H
2003-01-01
Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.
Defrance, Carine; Bollache, Emilie; Kachenoura, Nadjia; Perdrix, Ludivine; Hrynchyshyn, Nataliya; Bruguière, Eric; Redheuil, Alban; Diebold, Benoit; Mousseaux, Elie
2012-09-01
Accurate quantification of aortic valve stenosis (AVS) is needed for relevant management decisions. However, transthoracic Doppler echocardiography (TTE) remains inconclusive in a significant number of patients. Previous studies demonstrated the usefulness of phase-contrast cardiovascular magnetic resonance (PC-CMR) in noninvasive AVS evaluation. We hypothesized that semiautomated analysis of aortic hemodynamics from PC-CMR might provide reproducible and accurate evaluation of aortic valve area (AVA), aortic velocities, and gradients in agreement with TTE. We studied 53 AVS patients (AVA(TTE)=0.87±0.44 cm(2)) and 21 controls (AVA(TTE)=2.96±0.59 cm(2)) who had TTE and PC-CMR of aortic valve and left ventricular outflow tract on the same day. PC-CMR data analysis included left ventricular outflow tract and aortic valve segmentation, and extraction of velocities, gradients, and flow rates. Three AVA measures were performed: AVA(CMR1) based on Hakki formula, AVA(CMR2) based on continuity equation, AVA(CMR3) simplified continuity equation=left ventricular outflow tract peak flow rate/aortic peak velocity. Our analysis was reproducible, as reflected by low interoperator variability (<4.56±4.40%). Comparison of PC-CMR and TTE aortic peak velocities and mean gradients resulted in good agreement (r=0.92 with mean bias=-29±62 cm/s and r=0.86 with mean bias=-12±15 mm Hg, respectively). Although good agreement was found between TTE and continuity equation-based CMR-AVA (r>0.94 and mean bias=-0.01±0.38 cm(2) for AVA(CMR2), -0.09±0.28 cm(2) for AVA(CMR3)), AVA(CMR1) values were lower than AVA(TTE) especially for higher AVA (mean bias=-0.45±0.52 cm(2)). Besides, ability of PC-CMR to detect severe AVS, defined by TTE, provided the best results for continuity equation-based methods (accuracy >94%). Our PC-CMR semiautomated AVS evaluation provided reproducible measurements that accurately detected severe AVS and were in good agreement with TTE.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Indrajith, Sujatha Desai; Agarwal, Ravi
2017-01-01
A 26-year-old lady presented with exertional dyspnea, palpitations, central cyanosis, and oxygen saturations of 80% in room air. Her electrocardiogram, echocardiogram, and cardiac magnetic resonance were diagnostic of arrhythmogenic right ventricular dysplasia. There was no documented ventricular arrhythmia or syncopal episodes and Holter recordings were repeatedly normal. Cardiac hemodynamics showed right to left shunt through atrial septal defect, low pulmonary blood flow, normal atrial pressures, and minimally elevated right ventricular end-diastolic pressures. Since her presenting symptoms and cyanosis were attributed to reduced pulmonary blood flow, she underwent off-pump cavopulmonary anastomosis between right superior vena cava and right pulmonary artery. As we intended to avoid the adverse effect of extracorporeal circulation on the myocardial function and pulmonary vasculature, we did not attempt to reduce the size of the atrial septal defect. Her postoperative period was uneventful; oxygen saturation improved to 89% with significant improvement in effort tolerance. At 18-month follow-up, there were no ventricular arrhythmias on surveillance. The clinical presentation of this disease may vary from serious arrhythmias warranting defibrillators and electrical ablations at one end to right ventricular pump failure warranting cardiomyoplasty or right ventricular exclusion procedures at the other end. However, when the presentation was unusual with severe cyanosis through a stretched foramen ovale leading to reduced pulmonary blood flows, Glenn shunt served as a good palliation and should be considered as one of the options in such patients.
[Behavior of late ventricular potentials in acute experimental myocardial ischemia].
Duck, H J; Pankau, H; Köhler, H
1985-06-01
Locally retarded depolarizations of the ischaemic myocardium are regarded as frequent trigger mechanisms of dangerous ventricular arrhythmias. Up to now, however, there are scarcely systematic investigations concerning their concrete developmental conditions in man, since late potentials can be made evident only by means of expensive invasive methods or signal mediation techniques. Therefore, an animal model should be built, which is suitable for the control of new therapy conceptions with antiarrhythmic drugs. The investigations were performed on 22 pigs in whom under insufflation anaesthesia altogether 10 pressure, flow and contractility parameters as well as 6 epicardial ECG signals were continuously recorded. The episodes of ischaemia were caused by LAD occlusions of different duration and intensity. Typical late potentials could be registered in 5 animals who all had survived complete interruptions of the coronary blood flow of longer than 10 min. The mean duration of the late potentials was 20 +/- 9.2 ms, their amplitudes reached from 150 to 600 microV. Also with regard to time and cycle constancy, the delay of the late Q-potential and the morphology they corresponded to the homogeneous phenomenon, known from man. They always could be derived only from electrodes outside the immediate zone of ischaemia. Neither partial occlusions nor complete interruption of the coronary blood flow in intervals shorter than 10 minutes led to the development of a late potential. The animal model used altogether appears very suitable to investigate the medicamentous influencibility of arrhythmogenic areas of the myocardium under direct control of the dynamic behaviour of ventricular late potentials.
Cardiovascular function during sustained +G/z/ stress
NASA Technical Reports Server (NTRS)
Erickson, H. H.; Sandler, H.; Stone, H. L.
1976-01-01
The development of aerospace systems capable of very high levels of positive vertical accelerators stress has created a need for a better understanding of the cardiovascular responses to acceleration. Using a canine model, the heart and cardiovascular system were instrumented to continuously measure coronary blood flow, cardiac output, left ventricular and aortic root pressure, and oxygen saturation in the aorta, coronary sinus, and right ventricle. The animals were exposed to acceleration profiles up to +6 G, 120 s at peak G; a seatback angle of 45 deg was simulated in some experiments. Radiopaque contrast medium was injected to visualize the left ventricular chamber, coronary vasculature, aorta, and branches of the aorta. The results suggest mechanisms responsible for arrhythmias which may occur, and subendocardial hemorrhage which has been reported in other animals.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
Granegger, Marcus; Moscato, Francesco; Casas, Fernando; Wieselthaler, Georg; Schima, Heinrich
2012-08-01
Estimation of instantaneous flow in rotary blood pumps (RBPs) is important for monitoring the interaction between heart and pump and eventually the ventricular function. Our group has reported an algorithm to derive ventricular contractility based on the maximum time derivative (dQ/dt(max) as a substitute for ventricular dP/dt(max) ) and pulsatility of measured flow signals. However, in RBPs used clinically, flow is estimated with a bandwidth too low to determine dQ/dt(max) in the case of improving heart function. The aim of this study was to develop a flow estimator for a centrifugal pump with bandwidth sufficient to provide noninvasive cardiac diagnostics. The new estimator is based on both static and dynamic properties of the brushless DC motor. An in vitro setup was employed to identify the performance of pump and motor up to 20 Hz. The algorithm was validated using physiological ventricular and arterial pressure waveforms in a mock loop which simulated different contractilities (dP/dt(max) 600 to 2300 mm Hg/s), pump speeds (2 to 4 krpm), and fluid viscosities (2 to 4 mPa·s). The mathematically estimated pump flow data were then compared to the datasets measured in the mock loop for different variable combinations (flow ranging from 2.5 to 7 L/min, pulsatility from 3.5 to 6 L/min, dQ/dt(max) from 15 to 60 L/min/s). Transfer function analysis showed that the developed algorithm could estimate the flow waveform with a bandwidth up to 15 Hz (±2 dB). The mean difference between the estimated and measured average flows was +0.06 ± 0.31 L/min and for the flow pulsatilities -0.27 ± 0.2 L/min. Detection of dQ/dt(max) was possible up to a dP/dt(max) level of 2300 mm Hg/s. In conclusion, a flow estimator with sufficient frequency bandwidth and accuracy to allow determination of changes in ventricular contractility even in the case of improving heart function was developed. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Cilia driven flow networks in the brain
NASA Astrophysics Data System (ADS)
Wang, Yong; Faubel, Regina; Westendorf, Chrsitian; Eichele, Gregor; Bodenschatz, Eberhard
Neurons exchange soluble substances via the cerebrospinal fluid (CSF) that fills the ventricular system. The walls of the ventricular cavities are covered with motile cilia that constantly beat and thereby induce a directional flow. We recently discovered that cilia in the third ventricle generate a complex flow pattern leading to partitioning of the ventricular volume and site-directed transport paths along the walls. Transient and daily recurrent alterations in the cilia beating direction lead to changes in the flow pattern. This has consequences for delivery of CSF components along the near wall flow. The contribution of this cilia-induced flow to overall CSF flow remains to be investigated. The state-of-art lattice Boltzmann method is adapted for studying the CFS flow. The 3D geometry of the third ventricle at high resolution was reconstructed. Simulation of CSF flow without cilia in this geometry confirmed that the previous idea about unidirectional flow does not explain how different components of CSF can be delivered to their various target sites. We study the contribution of the cilia-induced flow pattern to overall CSF flow and identify target areas for site-specific delivery of CSF-constituents with respect to the temporal changes.
Oxygen and carbon dioxide transport in time-dependent blood flow past fiber rectangular arrays
NASA Astrophysics Data System (ADS)
Zierenberg, Jennifer R.; Fujioka, Hideki; Hirschl, Ronald B.; Bartlett, Robert H.; Grotberg, James B.
2009-03-01
The influence of time-dependent flows on oxygen and carbon dioxide transport for blood flow past fiber arrays arranged in in-line and staggered configurations was computationally investigated as a model for an artificial lung. Both a pulsatile flow, which mimics the flow leaving the right heart and passing through a compliance chamber before entering the artificial lung, and a right ventricular flow, which mimics flow leaving the right heart and directly entering the artificial lung, were considered in addition to a steady flow. The pulsatile flow was modeled as a sinusoidal perturbation superimposed on a steady flow while the right ventricular flow was modeled to accurately depict the period of flow acceleration (increasing flow) and deceleration (decreasing flow) during systole followed by zero flow during diastole. It was observed that the pulsatile flow yielded similar gas transport as compared to the steady flow, while the right ventricular flow resulted in smaller gas transport, with the decrease increasing with Re. The pressure drop across the fiber array (a measure of the resistance), work (an indicator of the work required of the right heart), and shear stress (a measure of potential blood cell activation and damage) are lowest for steady flow, followed by pulsatile flow, and then right ventricular flow. The pressure drop, work, shear stress, and Sherwood numbers (a measure of the gas transport efficiency) decrease with increasing porosity and are smaller for AR <1 as compared to AR >1 (AR is the distance between fibers in the flow direction/distance between fibers in direction perpendicular to flow), although for small porosities the Sherwood numbers are of similar magnitude. In general, for any fiber array geometry, high pressure drop, work, and shear stresses correlate with high Sherwood numbers, and low pressure drop, work, and shear stresses correlate with low Sherwood numbers creating a need for a compromise between pressure drop/work/shear stresses and gas transport.
Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.
Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R
1998-08-01
Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The degrees of increase of diastolic flows in the left anterior descending coronary artery and the ACB with IABP and LVAD were significantly greater than in the arterial grafts (p < 0.01). The diastolic flows in the internal thoracic artery and descending aorta-coronary bypass graft increased less than in the native left anterior descending coronary artery and ACB during left ventricular assistance, particularly with IABP. It is important for the selection of tactics for the management of catastrophic status after coronary bypass grafting to consider the hemodynamic characteristics of the graft.
Early signs that predict later haemodynamically significant patent ductus arteriosus.
Engür, Defne; Deveci, Murat; Türkmen, Münevver K
2016-03-01
Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.
Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R
2018-02-23
Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Influence of the hole geometry on the flow distribution in ventricular catheters for hydrocephalus.
Giménez, Ángel; Galarza, Marcelo; Pellicer, Olga; Valero, José; Amigó, José M
2016-07-15
Hydrocephalus is a medical condition consisting of an abnormal accumulation of cerebrospinal fluid within the brain. A catheter is inserted in one of the brain ventricles and then connected to an external valve to drain the excess of cerebrospinal fluid. The main drawback of this technique is that, over time, the ventricular catheter ends up getting blocked by the cells and macromolecules present in the cerebrospinal fluid. A crucial factor influencing this obstruction is a non-uniform flow pattern through the catheter, since it facilitates adhesion of suspended particles to the walls. In this paper we focus on the effects that tilted holes as well as conical holes have on the flow distribution and shear stress. We have carried out 3D computational simulations to study the effect of the hole geometry on the cerebrospinal fluid flow through ventricular catheters. All the simulations were done with the OpenFOAM® toolbox. In particular, three different groups of models were investigated by varying (i) the tilt angles of the holes, (ii) the inner and outer diameters of the holes, and (iii) the distances between the so-called hole segments. The replacement of cylindrical holes by conical holes was found to have a strong influence on the flow distribution and to lower slightly the shear stress. Tilted holes did not involve flow distribution changes when the hole segments are sufficiently separated, but the mean shear stress was certainly reduced. The authors present new results about the behavior of the fluid flow through ventricular catheters. These results complete earlier work on this topic by adding the influence of the hole geometry. The overall objective pursued by this research is to provide guidelines to improve existing commercially available ventricular catheters.
Kimura, Taro; Yokoyama, Yoshimasa; Sakota, Daisuke; Nagaoka, Eiki; Kitao, Takashi; Takakuda, Kazuo; Takatani, Setsuo
2013-03-01
The impact of continuous flow left ventricular assist device (LVAD) pumping on platelet aggregation was investigated in animal experiments utilizing six calves. A single-use MagLev centrifugal blood pump, MedTech MagLev, was used to bypass the calves' hearts from the left atrium to the descending aorta at a flow rate of 50 ml/kg/min. The LVAD's impact on blood coagulation activities was evaluated based on the platelet aggregability, which was measured with a turbidimetric assay method during the preoperative, operative, and postoperative periods. Heparin and warfarin were used for anticoagulation, while aspirin was used for the antiplatelet therapy. A decrease in platelet aggregation immediately after the pump started was observed in the cases of successful long-term pump operation, while the absence of such a decrease might have caused coagulation-related complications to terminate the experiments. Thus, the platelet aggregability was found to be significantly affected by the pump, and its initial trend may be related to the long-term outcome of the mechanical circulatory support.
Fluid dynamics model of mitral valve flow: description with in vitro validation.
Thomas, J D; Weyman, A E
1989-01-01
A lumped variable fluid dynamics model of mitral valve blood flow is described that is applicable to both Doppler echocardiography and invasive hemodynamic measurement. Given left atrial and ventricular compliance, initial pressures and mitral valve impedance, the model predicts the time course of mitral flow and atrial and ventricular pressure. The predictions of this mathematic formulation have been tested in an in vitro analog of the left heart in which mitral valve area and atrial and ventricular compliance can be accurately controlled. For the situation of constant chamber compliance, transmitral gradient is predicted to decay as a parabolic curve, and this has been confirmed in the in vitro model with r greater than 0.99 in all cases for a range of orifice area from 0.3 to 3.0 cm2, initial pressure gradient from 2.4 to 14.2 mm Hg and net chamber compliance from 16 to 29 cc/mm Hg. This mathematic formulation of transmitral flow should help to unify the Doppler echocardiographic and catheterization assessment of mitral stenosis and left ventricular diastolic dysfunction.
Vaujois, Laurence; Boucoiran, Isabelle; Preuss, Christophe; Brassard, Myriam; Houde, Christine; Fouron, Jean C; Raboisson, Marie-Josée
2017-09-01
The relationship between interatrial communication, ductus arteriosus, and pulmonary flow in transposition of the great arteries and intact ventricular septum may help predict postnatal desaturation. Echocardiographic data of 45 fetuses with transposition of the great arteries and intact ventricular septum and 50 age-matched controls were retrospectively reviewed. Interatrial communication, left and right ventricular output, flow in the ductus arteriosus, as well as effective pulmonary flow were measured. Patients were divided into two groups on the basis of postnatal saturations: group 1 had saturations ⩽50% and group 2 >50%. Of 45 fetuses, 13 (26.7%) were classified into group 1. Compared with fetuses in group 2, they had a smaller interatrial communication (2.9 versus 4.0 mm, p=0.004) and more retrograde diastolic flow in the ductus arteriosus (92 versus 23%, p=0.002). Both groups showed a significant decrease in ductal flow compared with controls. Patients in group 2 had a higher effective pulmonary flow compared with controls. There was a mild correlation between left ventricular output and size of the interatrial communication (Spearman's rank correlation 0.44). A retrograde diastolic flow is present in most of the fetuses with postnatal desaturation. Fetuses with transposition of the great arteries have a lower flow through the ductus arteriosus compared with controls. Fetuses without restrictive foramen ovale have higher effective pulmonary flow. Peripheral pulmonary vasodilatation due to higher oxygen saturation in pulmonary arteries in the case of transposition of the great arteries could be one possible cause.
Vest, Amanda R; Mistak, Stanley M; Hachamovitch, Rory; Mountis, Maria M; Moazami, Nader; Young, James B
2016-10-01
Diabetes mellitus (DM) is a risk factor for mortality among patients with heart failure as well as for patients who undergo cardiothoracic surgery. However it is unknown whether DM is associated with increased mortality or major complications during continuous-flow left ventricular assist device (CF-LVAD) support. We retrospectively reviewed 300 consecutive adults who received CF-LVADs at a single center in the years 2006-2013; 129 patients had DM before LVAD, as defined by American Diabetes Association criteria (HbA1c ≥6.5% and/or taking DM medications). Compared with the non-DM group, DM patients were older, with a higher pre-LVAD body mass index, more ischemic heart failure etiology, and higher pre-LVAD creatinine. Ninety-three patients died on LVAD support, 43 with DM and 50 without DM (P = .4526). After control for 9 covariates in a Cox proportional hazards model, DM was unassociated with all-cause mortality (hazard ratio 0.883, 95% confidence interval 0.571-1.366; P = .5768). Diabetes was also unassociated with the adverse event end points of stroke/transient ischemic attack, intracerebral hemorrhage, pump thrombosis, and device-related infections. Diabetes is common in LVAD recipients (43% of the present cohort) but does not increase mortality or rates of major adverse events during CF-LVAD support. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.
1986-07-01
Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less
Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse
NASA Technical Reports Server (NTRS)
Back, L. H.; Selzer, R. H.; Gordon, D. G.; Ledbetter, D. C.; Crawford, D. W.
1984-01-01
An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.
Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients.
Gurvits, Grigoriy E; Fradkov, Elena
2017-06-14
Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, postoperative and nonsurgical bleeding. A significant number of left ventricular assist devices (LVAD) recipients may experience recurrent gastrointestinal hemorrhage, mainly due to combination of antiplatelet and vitamin K antagonist therapy, activation of fibrinolytic pathway, acquired von Willebrand factor deficiency, and tendency to develop small intestinal angiodysplasias due to increased rotary speed of the pump. Gastrointestinal bleeding in LVAD patients remains a source of increased morbidity including the need for blood transfusions, extended hospital stays, multiple readmissions, and overall mortality. Management of gastrointestinal bleeding in LVAD patients involves multidisciplinary approach in stabilizing the patients, addressing risk factors and performing structured endoluminal evaluation with focus on upper gastrointestinal tract including jejunum to find and eradicate culprit lesion. Medical and procedural intervention is largely successful and universal bleeding cessation occurs in transplanted patients.
A computer model of the pediatric circulatory system for testing pediatric assist devices.
Giridharan, Guruprasad A; Koenig, Steven C; Mitchell, Michael; Gartner, Mark; Pantalos, George M
2007-01-01
Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.
Mouton Paradot, Gaëlle; Baledent, Olivier; Sallioux, Guillaume; Lehmann, Pierre; Gondry-Jouet, Catherine; Le Gars, Daniel
2010-02-01
The diagnosis and management of patients with idiopathic normal-pressure hydrocephalus (NPH) remain somewhat controversial and there is no clear guideline for assessing the post-shunt outcome. The objective of this study was to investigate whether cerebrospinal fluid (CSF) flow dynamics is linked to post-shunt improvement. Fourteen NPH patients (nine males and five females; mean age, 68 years) investigated by magnetic resonance imaging (MRI) before surgical diversion of CSF were retrospectively reviewed. Phase-contrast sequences were added to the morphological clinical protocol for quantification of CSF oscillations, which were recorded at the level of the cerebral aqueduct and the C2 and C3 subarachnoid spaces (SAS). The phase-contrast images were analysed with custom-designed dedicated flow segmentation software. The oscillations measured in this hydrocephalus population were compared to a previously studied healthy population. A difference of at least two standard deviations was used to define a hyperdynamic or hypodynamic state of CSF flow. The cervical CSF flow of the hydrocephalus patients was not significantly different from those of the volunteer population. Of the 14 hydrocephalus patients, 12 had a good response to the shunt. Of these, 10 presented an increased ventricular CSF flow, one a low ventricular CSF flow, and the last one had a normal ventricular CSF flow. Phase-contrast MRI can help develop guidelines for surgical management of NPH. The shunt responders appear to be the patients with hyperdynamic ventricular CSF flow and normal cervical CSF flow. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Honda, Takashi; Itatani, Keiichi; Takanashi, Manabu; Kitagawa, Atsushi; Ando, Hisashi; Kimura, Sumito; Oka, Norihiko; Miyaji, Kagami; Ishii, Masahiro
2017-10-01
Vector flow mapping is a novel echocardiographic flow visualization method, and it has enabled us to quantitatively evaluate the energy loss in the left ventricle (intraventricular energy loss). Although intraventricular energy loss is assumed to be a part of left ventricular workload itself, it is unclear what this parameter actually represents. The aim of the present study was to elucidate the characteristics of intraventricular energy loss. We enrolled 26 consecutive children with ventricular septal defect (VSD). On echocardiography vector flow mapping, intraventricular energy loss was measured in the apical 3-chamber view. We measured peak energy loss and averaged energy loss in the diastolic and systolic phases, and subsequently compared these parameters with catheterization parameters and serum brain natrium peptide (BNP) level. Diastolic, peak, and systolic energy loss were strongly and positively correlated with right ventricular systolic pressure (r=0.76, 0.68, and 0.56, p<0.0001, = 0.0001, and 0.0029, respectively) and right ventricular end diastolic pressure (r=0.55, 0.49, and 0.49, p=0.0038, 0.0120, and 0.0111, respectively). In addition, diastolic, peak, and systolic energy loss were significantly correlated with BNP (r=0.75, 0.69 and 0.49, p<0.0001, < 0.0001, and=0.0116, respectively). In children with VSD, elevated right ventricular pressure is one of the factors that increase energy loss in the left ventricle. The results of the present study encourage further studies in other study populations to elucidate the characteristics of intraventricular energy loss for its possible clinical application. Copyright © 2017 Elsevier B.V. All rights reserved.
Ma, Jianying; Qian, Juying; Zeng, Xin; Sun, Aijun; Chang, Shufu; Chen, Zhangwei; Zou, Yunzeng
2012-01-01
Introduction Although coronary microembolization (CME) is a frequent phenomenon in patients undergoing percutaneous coronary intervention, few data are available on the changes in left ventricular ejection fraction (LVEF) and coronary flow reserve (CFR) after CME. Material and methods In this study, six miniature swine of either sex (body weight 21-25 kg) were used to prepare a CME model. After coronary angiography, 1.2 × 105 microspheres (42 µm) were selectively infused into the left anterior descending artery via an infusion catheter. Left ventricular ejection fraction was evaluated using transthoracic echocardiography; myocardial blood flow was measured using coloured microspheres; and CFR and coronary pressure were measured using Doppler and a pressure wire. Results Left ventricular ejection fraction was 0.77 ±0.08 at baseline, 0.69 ±0.08 at 2 h, 0.68 ±0.08 at 6 h, and 0.76 ±0.06 at 1 week (2 h vs. baseline p < 0.05; 6 h vs. baseline p < 0.01). After CME, left ventricular end systolic volume (LVESV) and end diastolic volume (LVEDV) were significant larger 1 week later (p < 0.01 for both), while CFR was significantly reduced at 6 h (1.24 ±0.10 at 6 h vs. 1.77 ±0.30 at baseline, p < 0.01) and myocardial blood flow remained unchanged. Serum ET-1 level was significantly higher only at 6 h after CME (6 h vs. baseline p < 0.05). Conclusions Reduction of CFR and LVEF is significant at 6 h after CME and recovers 1 week later with left ventricular dilation. PMID:22457677
Obel, O A; Luddington, L; Maarouf, N; Aytemir, K; Ekwall, C; Malik, M; Camm, A J
2005-01-01
Objective: To prospectively determine whether ventricular rate and regularity are significant determinants of the velocity and magnitude of left atrial appendage (LAA) flow. Design and patients: 12 patients with atrial fibrillation (AF), high degree atrioventricular block, and indwelling permanent pacemakers were studied. Setting: Cardiology department of a tertiary referral centre. Interventions: Pacing was triggered by an external programmable transcutaneous device. Patients were paced at 60, 120, and 150 beats/min in both regular and irregular rhythm. LAA flow velocity and magnitude were assessed with transoesophageal Doppler echocardiography. Main outcome measures: Peak and mean LAA inflow and outflow velocity, and time-velocity interval (TVI) of LAA flow. Results: Increasing ventricular rate was associated with significantly lower peak inflow (p < 0.01), peak outflow (p < 0.05), mean inflow (p < 0.01), and mean outflow (p < 0.05) velocities and with a lower TVI of LAA filling and emptying velocities (p < 0.01). This effect was noted at rates of 60 beats/min compared with both 120 and 150 beats/min. At a pacing rate of 120 beats/min there was a significantly higher total TVI when pacing at a regular than at an irregular rhythm (40.16 (14.6) cm v 30.74 (10.9) cm, p < 0.05). Conclusions: In this study, LAA filling velocities in patients in AF were significantly influenced by paced ventricular rate and to a much lesser extent ventricular rhythm. These results suggest that rapid ventricular rates may predispose to stasis in the LAA in AF. PMID:15894771
NASA Astrophysics Data System (ADS)
Larsson, David; Spühler, Jeannette H.; Günyeli, Elif; Weinkauf, Tino; Hoffman, Johan; Colarieti-Tosti, Massimiliano; Winter, Reidar; Larsson, Matilda
2017-03-01
Echocardiography is the most commonly used image modality in cardiology, assessing several aspects of cardiac viability. The importance of cardiac hemodynamics and 4D blood flow motion has recently been highlighted, however such assessment is still difficult using routine echo-imaging. Instead, combining imaging with computational fluid dynamics (CFD)-simulations has proven valuable, but only a few models have been applied clinically. In the following, patient-specific CFD-simulations from transthoracic dobutamin stress echocardiography have been used to analyze the left ventricular 4D blood flow in three subjects: two with normal and one with reduced left ventricular function. At each stress level, 4D-images were acquired using a GE Vivid E9 (4VD, 1.7MHz/3.3MHz) and velocity fields simulated using a presented pathway involving endocardial segmentation, valve position identification, and solution of the incompressible Navier-Stokes equation. Flow components defined as direct flow, delayed ejection flow, retained inflow, and residual volume were calculated by particle tracing using 4th-order Runge-Kutta integration. Additionally, systolic and diastolic average velocity fields were generated. Results indicated no major changes in average velocity fields for any of the subjects. For the two subjects with normal left ventricular function, increased direct flow, decreased delayed ejection flow, constant retained inflow, and a considerable drop in residual volume was seen at increasing stress. Contrary, for the subject with reduced left ventricular function, the delayed ejection flow increased whilst the retained inflow decreased at increasing stress levels. This feasibility study represents one of the first clinical applications of an echo-based patient-specific CFD-model at elevated stress levels, and highlights the potential of using echo-based models to capture highly transient flow events, as well as the ability of using simulation tools to study clinically complex phenomena. With larger patient studies planned for the future, and with the possibility of adding more anatomical features into the model framework, the current work demonstrates the potential of patient-specific CFD-models as a tool for quantifying 4D blood flow in the heart.
Kingma, J G; Linderoth, B; Ardell, J L; Armour, J A; DeJongste, M J; Foreman, R D
2001-08-13
Electrical stimulation of the dorsal aspect of the upper thoracic spinal cord is used increasingly to treat patients with angina pectoris refractory to conventional therapeutic strategies. The purpose of this study was to determine whether spinal cord stimulation (SCS) in dogs affects regional myocardial blood flow and left-ventricular (LV) function before and during transient obstruction of the left anterior descending coronary artery (LAD). In anesthetized dogs, regional myocardial blood flow distribution was determined using radiolabeled microspheres and left-ventricular function was measured by impedance-derived pressure-volume loops. SCS was accomplished by stimulating the dorsal T1-T2 segments of the spinal cord using epidural bipolar electrodes at 90% of motor threshold (MT) (50 Hz, 0.2-ms duration). Effects of 5-min SCS were assessed under basal conditions and during 4-min occlusion of the LAD. SCS alone evoked no change in regional myocardial blood flow or cardiovascular indices. Transient LAD occlusion significantly diminished blood flow within ischemic, but not in non-ischemic myocardial tissue. Left ventricular pressure-volume loops were shifted rightward during LAD occlusion. Cardiac indices were altered similarly during LAD occlusion and concurrent SCS. SCS does not influence the distribution of blood flow within the non-ischemic or ischemic myocardium. Nor does it modify LV pressure-volume dynamics in the anesthetized experimental preparation.
Di Molfetta, Arianna; Ferrari, Gianfranco; Iacobelli, Roberta; Filippelli, Sergio; Fresiello, Libera; Gagliardi, Maria G; Toscano, Alessandro; Trivella, Maria G; Amodeo, Antonio
2015-12-01
Right ventricular failure (RVF) is one of the major complications during LVAD. Apart from drug therapy, the most reliable option is the implantation of RVAD. However, BIVAD have a poor prognosis and increased complications. Experiments have been conducted on alternative approaches, such as the creation of an atrial septal defect (ASD), a cavo-aortic shunt (CAS) including the LVAD and a cavo-pulmonary connection (CPC). This work aims at realizing a lumped parameter model (LPM) to compare the acute hemodynamic effects of ASD, CPC, CAS, RVAD in LVAD pediatric patients with RVF. Data of 5 pediatric patients undergoing LVAD were retrospectively collected to reproduce patients baseline hemodynamics with the LPM. The effects of continuous flow LVAD implantation complicated by RVF was simulated and then the effects of ASD, CPC, CAS and RVAD treatments were simulated for each patient. The model successfully reproduced patients' baseline and the hemodynamic effects of the surgical strategies. Simulating the different surgical strategies, an unloading of the right ventricle and an increment of left ventricular preload were observed with an improvement of the hemodynamics (total cardiac output: ASD +15%, CPC +10%, CAS +70% RVAD +20%; right ventricular external work: ASD -19%, CPC -46%, CAS -76%, RVAD -32%; left ventricular external work: ASD +12%, CPC +28%, RVAD +64%). The use of numerical model could offer an additional support for clinical decision-making, also potentially reducing animal experiments, to compare the outcome of different surgical strategies to treat RVF in LVAD.
In vivo quantification of intraventricular flow during left ventricular assist device support
NASA Astrophysics Data System (ADS)
Vu, Vi; Wong, Kin; Del Alamo, Juan; Aguilo, Pablo M. L.; May-Newman, Karen; Department of Bioengineering, San Diego State University Collaboration; Department of Mechanical; Aerospace Engineering, University of California San Diego Collaboration; Mechanical Assist Device Program, Sharp Memorial Hospital Collaboration
2014-11-01
Left ventricular assist devices (LVADs) are mechanical pumps that are surgically connected to the left ventricle (LV) and aorta to increase aortic flow and end-organ perfusion. Clinical studies have demonstrated that LVADs improve patient health and quality of life and significantly reduce the mortality of cardiac failure. However, In the presence of left ventricular assisted devices (LVAD), abnormal flow patterns and stagnation regions are often linked to thrombosis. The aim of our study is to evaluate the flow patterns in the left ventricle of the LVAD-assisted heart, with a focus on alterations in vortex development and blood stasis. To this aim, we applied color Doppler echocardiography to measure 2D, time resolved velocity fields in patients before and after implantation of LVADs. In agreement with our previous in vitro studies (Wong et al., Journal of Biomechanics 47, 2014), LVAD implantation resulted in decreased flow velocities and increased blood residence time near the outflow tract. The variation of residence time changes with LVAD operational speed was characterized for each patient.
Krauss, J K; Regel, J P; Vach, W; Jüngling, F D; Droste, D W; Wakhloo, A K
1997-01-01
We investigate the predictive value of cerebrospinal fluid (CSF) flow void on outcome after shunting in a prospective series of patients with idiopathic normal pressure hydrocephalus (NPH). The degree and extension of CSF flow void were examined on T2-weighted magnetic resonance imaging scans of 37 elderly patients with idiopathic NPH who underwent subsequent shunting. The degree of flow void was assessed in comparison with the signal of large cerebral arteries. The extension was evaluated via the calculation of sum scores for the occurrence of flow void in different locations of the ventricular system. Those parameters were not considered in the decision to perform shunting. CSF flow void in the aqueduct and the adjacent third and fourth ventricles of the 37 patients with idiopathic NPH was compared with that of 37 age-matched control patients. CSF flow void scores in patients with idiopathic NPH were investigated for correlations between postoperative outcome scores and ventricular width indices. No difference was found between the occurrence of aqueductal CSF flow void in patients with idiopathic NPH and the control group. A significant difference, however, was noted for the extension of the CSF flow void, which was greater in the NPH group. Postoperative improvement was found in 33 of 37 patients with idiopathic NPH at a mean follow-up of 15.6 months. Only small, statistically not significant correlations were found between CSF flow void and postoperative outcome. Flow void sum scores, however, correlated significantly with ventricular width indices. The degree and extension of CSF flow void on T2-weighted magnetic resonance imaging scans have little predictive value for outcome after shunting in patients with idiopathic NPH. The greater extension of the CSF flow void in patients with NPH is most likely related to increased ventricular width. It is not useful to consider CSF flow void findings on conventional magnetic resonance imaging scans in making the decision to offer shunting in patients with idiopathic NPH.
Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S
1997-01-01
We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.
Takaseya, Tohru; Fumoto, Hideyuki; Shiose, Akira; Arakawa, Yoko; Rao, Santosh; Horvath, David J; Massiello, Alex L; Mielke, Nicole; Chen, Ji-Feng; Zhou, Qun; Dessoffy, Raymond; Kramer, Larry; Benefit, Stephen; Golding, Leonard A R; Fukamachi, Kiyotaka
2010-12-01
The purpose of this study was to evaluate in vivo the biocompatibility of BioMedFlex (BMF), a new resilient, hard-carbon, thin-film coating, as a blood journal bearing material in Cleveland Heart's (Charlotte, NC, USA) continuous-flow right and left ventricular assist devices (RVADs and LVADs). BMF was applied to RVAD rotating assemblies or both rotating and stator assemblies in three chronic bovine studies. In one case, an LVAD with a BMF-coated stator was also implanted. Cases 1 and 3 were electively terminated at 18 and 29 days, respectively, with average measured pump flows of 4.9 L/min (RVAD) in Case 1 and 5.7 L/min (RVAD) plus 5.7 L/min (LVAD) in Case 3. Case 2 was terminated prematurely after 9 days because of sepsis. The sepsis, combined with running the pump at minimum speed (2000 rpm), presented a worst-case biocompatibility challenge. Postexplant evaluation of the blood-contacting journal bearing surfaces showed no biologic deposition in any of the four pumps. Thrombus inside the RVAD inlet cannula in Case 3 is believed to be the origin of a nonadherent thrombus wrapped around one of the primary impeller blades. In conclusion, we demonstrated that BMF coatings can provide good biocompatibility in the journal bearing for ventricular assist devices. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Litzler, Pierre-Yves; Smail, Hassiba; Barbay, Virginie; Nafeh-Bizet, Catherine; Bouchart, François; Baste, Jean-Marc; Abriou, Caroline; Bessou, Jean-Paul
2014-01-01
We report our 5-year experience of continuous flow left ventricular assist device (LVAD) implantation without the use of anti-platelet therapy. Between February 2006 and September 2011, 27 patients (26 men; 1 woman) were implanted with a continuous flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, CA, USA). The mean age was 55.7 ± 9.9 years. The mean duration of support was 479 ± 436 (1-1555) days with 35.4 patient-years on support. Twenty-one patients were implanted as a bridge to transplantation and 6 for destination therapy. The anticoagulation regimen was fluindione for all patients, with aspirin for only 4 patients. At the beginning of our experience, aspirin was administered to 4 patients for 6, 15, 60 and 460 days. Due to gastrointestinal (GI) bleeding and epistaxis, aspirin was discontinued, and since August 2006, no patients have received anti-platelet therapy. At 3 years, the survival rate during support was 76%. The most common postoperative adverse event was GI bleeding (19%) and epistaxis (30%) (median time: 26 days) for patients receiving fluindione and aspirin. The mean International Normalized Ratio (INR) was 2.58 ± 0.74 during support. Fifteen patients have been tested for acquired Von Willebrand disease. A diminished ratio of collagen-binding capacity and ristocetin cofactor activity to Von Willebrand factor antigen was observed in 7 patients. In the postoperative period, 2 patients presented with ischaemic stroke at 1 and 8 months. One of these 2 patients had a previous history of carotid stenosis with ischaemic stroke. There were no patients with haemorrhagic stroke, transient ischaemic attack or pump thrombosis. The event rate of stroke (ischaemic and haemorrhagic) per patient-year was 0.059 among the patients without aspirin with fluindione regimen only. A fluindione regimen without aspirin in long-duration LVAD support appears to not increase thromboembolic events and could lead to a diminished risk of haemorrhagic stroke.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, C.G.; Werman, H.A.; Davis, E.A.
1987-02-01
Although epinephrine has been shown to improve myocardial blood flow during cardiopulmonary resuscitation (CPR), the effects of standard as well as larger doses of epinephrine on regional myocardial blood flow have not been examined. In this study we compared the effects of various doses of epinephrine on regional myocardial blood flow after a 10 min arrest in a swine preparation. Fifteen swine weighing greater than 15 kg each were instrumented for regional myocardial blood flow measurements with tracer microspheres. Regional blood flow was measured during normal sinus rhythm. After 10 min of ventricular fibrillation, CPR was begun and regional myocardialmore » blood flow was determined. Animals were then randomly assigned to receive 0.02, 0.2, or 2.0 mg/kg epinephrine by peripheral injection. One minute after drug administration, regional myocardial blood flow measurements were repeated. The adjusted regional myocardial blood flows (ml/min/100 g) for animals given 0.02, 0.2, and 2.0 mg/kg epinephrine, respectively, were as follows: left atrium, 0.9, 67.4, and 58.8; right atrium, 0.3, 46.2, and 38.5; right ventricle, 0.7, 82.3, and 66.9; right interventricular septum, 1.7, 125.5, and 99.1; left interventricular septum, 2.8, 182.8, 109.5; mesointerventricular septum, 16.8, 142.2, and 79.2; left ventricular epicardium, 19.2, 98.5 and 108.7; left ventricular mesocardium, 22.8, 135.0, and 115.8; and left ventricular endocardium, 2.5, 176.1, and 132.9). All comparisons between the groups receiving 0.02 and 0.2 mg/kg epinephrine were statistically significant (p less than .05).« less
Sjöberg, Pia; Bidhult, Sebastian; Bock, Jelena; Heiberg, Einar; Arheden, Håkan; Gustafsson, Ronny; Nozohoor, Shahab; Carlsson, Marcus
2018-04-17
Indications for pulmonary valve replacement (PVR) in patients with pulmonary regurgitation (PR) after repaired tetralogy of Fallot (rToF) are debated. We aimed to compare right (RV) and left ventricular (LV) kinetic energy (KE) measured by 4D-flow magnetic resonance imaging (MRI) in patients to controls, to further understand the pathophysiological effects of PR. Fifteen patients with rToF with PR > 20% and 14 controls underwent MRI. Ventricular volumes and KE were quantified from cine MRI and 4D-flow, respectively. Lagrangian coherent structures were used to discriminate KE in the PR. Restrictive RV physiology was defined as end-diastolic forward flow. LV systolic peak KE was lower in rToF, 2.8 ± 1.1 mJ, compared to healthy volunteers, 4.8 ± 1.1 mJ, p < 0.0001. RV diastolic peak KE was higher in rToF (7.7 ± 4.3 mJ vs 3.1 ± 1.3 mJ, p = 0.0001) and the difference most pronounced in patients with non-restrictive RV physiology. KE was primarily located in the PR volume at the time of diastolic peak KE, 64 ± 17%. This is the first study showing disturbed KE in patients with rToF and PR, in both the RV and LV. The role of KE as a potential early marker of ventricular dysfunction to guide intervention needs to be addressed in future studies. • Kinetic energy (KE) reflects ventricular performance • KE is a potential marker of ventricular dysfunction in Fallot patients • KE is disturbed in both ventricles in patients with tetralogy of Fallot • KE contributes to the understanding of the pathophysiology of pulmonary regurgitation • Lagrangian coherent structures enable differentiation of ventricular inflows.
Djordjevic Dikic, Ana; Nikcevic, Gabrijela; Raspopovic, Srdjan; Jovanovic, Velibor; Tesic, Milorad; Beleslin, Branko; Stepanovic, Jelena; Giga, Vojislav; Milasinovic, Goran
2014-12-01
The aim of the study was to assess the value of coronary flow reserve (CFR) for predicting improvement of left ventricular function after cardiac resynchronization therapy (CRT). Study population included 40 patients (mean age 58 ± 9 years) with heart failure (ejection fraction 25, 7 ± 5, 4%) and QRS duration of 158 ± 22 ms, planned for CRT. Before and after CRT implantation, CFR was measured non-invasively during hyperaemia induced with adenosine. Responders were defined by decrease in end-systolic volume ≥15%. Follow-up echocardiography and CFR measurements were obtained after 6 months. At baseline there was no significant difference in left ventricular ejection fraction (LVEF), QRS duration, 6 min walk test distance and coronary flow velocity at rest between responder (n = 26) vs. non-responder group (n = 14, P = ns). Before CRT implantation, responders compared with non-responders, showed a greater increase in coronary flow velocity during hyperaemia, and consequently higher CFR: 2.41 ± 0.60 vs. 1.61 ± 0.45 (P = 0.001). There was significant correlation between CFR before CRT implantation and LVEF after 6 months (r = 0.545, P = 0.001). End-diastolic, end-systolic left ventricular diameter, and CFR before CRT were predictors of LV functional improvement. By multivariate analysis, only CFR before CRT was independent predictor of left ventricular recovery in the follow-up period (P = 0.001). Our results demonstrate that preserved CFR in patients with dilated cardiomyopathy is predictive of left ventricular improvement after CRT implantation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Kishimoto, Satoru; Takewa, Yoshiaki; Tsukiya, Tomonori; Mizuno, Toshihide; Date, Kazuma; Sumikura, Hirohito; Fujii, Yutaka; Ohnuma, Kentaro; Togo, Konomi; Katagiri, Nobumasa; Naito, Noritsugu; Kishimoto, Yuichiro; Nakamura, Yoshinobu; Nishimura, Motonobu; Tatsumi, Eisuke
2018-03-01
The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58-68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000-4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.
Arvidsson, Per M; Töger, Johannes; Carlsson, Marcus; Steding-Ehrenborg, Katarina; Pedrizzetti, Gianni; Heiberg, Einar; Arheden, Håkan
2017-02-01
Intracardiac blood flow is driven by hemodynamic forces that are exchanged between the blood and myocardium. Previous studies have been limited to 2D measurements or investigated only left ventricular (LV) forces. Right ventricular (RV) forces and their mechanistic contribution to asymmetric redirection of flow in the RV have not been measured. We therefore aimed to quantify 3D hemodynamic forces in both ventricles in a cohort of healthy subjects, using magnetic resonance imaging 4D flow measurements. Twenty five controls, 14 elite endurance athletes, and 2 patients with LV dyssynchrony were included. 4D flow data were used as input for the Navier-Stokes equations to compute hemodynamic forces over the entire cardiac cycle. Hemodynamic forces were found in a qualitatively consistent pattern in all healthy subjects, with variations in amplitude. LV forces were mainly aligned along the apical-basal longitudinal axis, with an additional component aimed toward the aortic valve during systole. Conversely, RV forces were found in both longitudinal and short-axis planes, with a systolic force component driving a slingshot-like acceleration that explains the mechanism behind the redirection of blood flow toward the pulmonary valve. No differences were found between controls and athletes when indexing forces to ventricular volumes, indicating that cardiac force expenditures are tuned to accelerate blood similarly in small and large hearts. Patients' forces differed from controls in both timing and amplitude. Normal cardiac pumping is associated with specific force patterns for both ventricles, and deviation from these forces may be a sensitive marker of ventricular dysfunction. Reference values are provided for future studies. NEW & NOTEWORTHY Biventricular hemodynamic forces were quantified for the first time in healthy controls and elite athletes (n = 39). Hemodynamic forces constitute a slingshot-like mechanism in the right ventricle, redirecting blood flow toward the pulmonary circulation. Force patterns were similar between healthy subjects and athletes, indicating potential utility as a cardiac function biomarker. Copyright © 2017 the American Physiological Society.
Bartoli, Carlo R; Kang, Jooeun; Zhang, David; Howard, Jessica; Acker, Michael; Atluri, Pavan; Motomura, Tadashi
2017-04-01
Supraphysiologic shear stress from continuous-flow left ventricular assist devices (LVADs) accelerates von Willebrand factor (vWF) degradation and predisposes patients to nonsurgical bleeding. It is unknown whether unique design characteristics of LVADs differentially affect vWF degradation. We tested the hypothesis that the centrifugal-flow EVAHEART (Evaheart, Houston, TX) left ventricular assist system (LVAS), which was designed to minimize shear stress (low operational revolutions per minute [rpm], larger flow gaps, low shear stress, flat H-Q curve), reduced vWF degradation versus the axial-flow HeartMate II (Thoratec, Pleasanton, CA) LVAD. Whole human blood was obtained from volunteer donors (n = 22). Blood was circulated for 12 hours in mock circulatory loops through a HeartMate II (n = 10; 11,400 rpm, 6.3 ± 0.8 L/min, 76 ± 2 mm Hg) or an EVAHEART LVAS (n = 12; 2,300 rpm, 5.7 ± 0.1 L/min, 80 ± 1 mm Hg). vWF degradation was characterized with electrophoresis and immunoblotting for large vWF multimers and 11 vWF degradation fragments. The HeartMate II eliminated large vWF multimers and significantly (p < 0.05) increased 10 of 11 vWF degradation fragments at 6 and 12 hours. The increase was approximately 2.0-fold at 6 hours and 2.2-fold at 12 hours. In contrast, the EVAHEART LVAS modestly reduced large vWF multimers and significantly increased 5 of 11 and 8 of 11 vWF degradation fragments at 6 and 12 hours, respectively. The increase was approximately 1.5-fold at 6 hours and 1.7-fold at 12 hours. The EVAHEART LVAS caused significantly less degradation (p < 0.01) than the HeartMate II of the 140 kDa vWF fragment (cleavage product of ADAMTS-13, the vWF protease). The EVAHEART LVAS caused significantly less vWF degradation than the HeartMate II in a mock circulatory loop with whole human blood. LVAD design features may minimize vWF degradation. These data may inform the design and operation of next-generation LVADs to minimize blood trauma. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Traeger, Brad; Srivatsa, Sanjay S.; Beussman, Kevin M.; Wang, Yechun; Suzen, Yildirim B.; Rybicki, Frank J.; Mazur, Wojciech; Miszalski-Jamka, Tomasz
2016-04-01
Aortic stenosis is the most common valvular heart disease. Assessing the contribution of the valve as a portion to total ventricular load is essential for the aging population. A CT scan for one patient was used to create one in vivo tricuspid aortic valve geometry and assessed with computational fluid dynamics (CFD). CFD simulated the pressure, velocity, and flow rate, which were used to assess the Gorlin formula and continuity equation, current clinical diagnostic standards. The results demonstrate an underestimation of the anatomic orifice area (AOA) by Gorlin formula and overestimation of AOA by the continuity equation, using peak velocities, as would be measured clinically by Doppler echocardiography. As a result, we suggest that the Gorlin formula is unable to achieve the intended estimation of AOA and largely underestimates AOA at the critical low-flow states present in heart failure. The disparity in the use of echocardiography with the continuity equation is due to the variation in velocity profile between the outflow tract and the valve orifice. Comparison of time-averaged orifice areas by Gorlin and continuity with instantaneous orifice areas by planimetry can mask the errors of these methods, which is a result of the assumption that the blood flow is inviscid.
Lim, Ki Moo; Constantino, Jason; Gurev, Viatcheslav; Zhu, Renjun; Trayanova, Natalia A.
2012-01-01
Left ventricular-assist devices (LVADs) are used to supply blood to the body of patients with heart failure. Pressure unloading is greater for counter-pulsating LVADs than for continuous LVADs. However, several clinical trials have demonstrated that myocardial recovery is similar for both types of LVAD. This study examined the contractile energy consumption of the myocardium with continuous and counter-pulsating LVAD support to ascertain the effect of the different LVADs on myocardial recovery. We used a three-dimensional electromechanical model of canine ventricles, with models of the circulatory system and an LVAD. We compared the left ventricular peak pressure (LVPP) and contractile ATP consumption between pulsatile and continuous LVADs. With the continuous and counter-pulsating LVAD, the LVPP decreased to 46 and 10%, respectively, and contractile ATP consumption decreased to 60 and 50%. The small difference between the contractile ATP consumption of these two types of LVAD may explain the comparable effects of the two types on myocardial recovery. PMID:22076841
Fischer, Quentin; Huisse, Marie-Geneviève; Voiriot, Guillaume; Caron, Claudine; Lepage, Laurent; Dilly, Marie-Pierre; Nataf, Patrick; Ajzenberg, Nadine; Kirsch, Matthias
2015-01-01
Bleeding originating in the gastrointestinal (GI) tract is one of the most common adverse events after left ventricular assist device (LVAD) implantation. In these patients, GI bleeding appears to be the consequence of altered hemostasis on the one hand and alterations of the GI microvasculature on the other. We report the case of a patient who suffered repeated, severe GI bleeding early after implantation of a HeartMate II continuous-flow LVAD. After failure of conventional treatment strategies, GI bleeding was controlled using repeated transfusions of a purified von Willebrand factor (VWF) concentrate, almost devoid of Factor VIII (Wilfactin, LFB). No episodes of pump thrombosis were noted. Subsequent to VWF transfusions, we observed a progressive normalization of circulating vascular endothelial growth factor levels. Our data raise the possibility that, in addition to its hemostatic properties, transfusions of VWF might have acted as an antiangiogenic factor. © 2014 AABB.
Koueik, Joyce; Rocque, Brandon G; Henry, Jordan; Bragg, Taryn; Paul, Jennifer; Iskandar, Bermans J
2018-02-01
Continuous irrigation is an important adjunct for successful intraventricular endoscopy, particularly for complex cases. It allows better visualization by washing out blood and debris, improves navigation by expanding the ventricles, and assists with tissue dissection. A method of irrigation delivery using a centrifugal pump designed originally for cardiac surgery is presented. The BioMedicus centrifugal pump has the desirable ability to deliver a continuous laminar flow of fluid that excludes air from the system. A series of modifications to the pump tubing was performed to adapt it to neuroendoscopy. Equipment testing determined flow and pressure responses at various settings and simulated clinical conditions. The pump was then studied clinically in 11 endoscopy cases and eventually used in 310 surgical cases. Modifications of the pump tubing allowed for integration with different endoscopy systems. Constant flow rates were achieved with and without surgical instruments through the working ports. Optimal flow rates ranged between 30 and 100 ml/min depending on endoscope size. Intraoperative use was well tolerated with no permanent morbidity and showed consistent flow rates, minimal air accumulation, and seamless irrigation bag replacement during prolonged surgery. Although the pump is equipped with an internal safety mechanism to protect against pressure buildup when outflow obstructions occur, equipment testing revealed that flow cessation is not instantaneous enough to protect against sudden intracranial pressure elevation. A commonly available cardiac pump system was modified to provide continuous irrigation for intraventricular endoscopy. The system alleviates the problems of inconsistent flow rates, air in the irrigation lines, and delays in changing irrigation bags, thereby optimizing patient safety and surgical efficiency. Safe use of the pump requires good ventricular outflow and, clearly, sound surgical judgment.
Arvidsson, Per M; Töger, Johannes; Heiberg, Einar; Carlsson, Marcus; Arheden, Håkan
2013-05-15
Kinetic energy (KE) of atrial blood has been postulated as a possible contributor to ventricular filling. Therefore, we aimed to quantify the left (LA) and right (RA) atrial blood KE using cardiac magnetic resonance (CMR). Fifteen healthy volunteers underwent CMR at 3 T, including a four-dimensional phase-contrast flow sequence. Mean LA KE was lower than RA KE (1.1 ± 0.1 vs. 1.7 ± 0.1 mJ, P < 0.01). Three KE peaks were seen in both atria: one in ventricular systole, one during early ventricular diastole, and one during atrial contraction. The systolic LA peak was significantly smaller than the RA peak (P < 0.001), and the early diastolic LA peak was larger than the RA peak (P < 0.05). Rotational flow contained 46 ± 7% of total KE and conserved energy better than nonrotational flow did. The KE increase in early diastole was higher in the LA (P < 0.001). Systolic KE correlated with the combination of atrial volume and systolic velocity of the atrioventricular plane displacement (r(2) = 0.57 for LA and r(2) = 0.64 for RA). Early diastolic KE of the LA correlated with left ventricle (LV) mass (r(2) = 0.28), however, no such correlation was found in the right heart. This suggests that LA KE increases during early ventricular diastole due to LV elastic recoil, indicating that LV filling is dependent on diastolic suction. Right ventricle (RV) relaxation does not seem to contribute to atrial KE. Instead, RA KE generated during ventricular systole may be conserved in a hydraulic "flywheel" and transferred to the RV through helical flow, which may contribute to RV filling.
Amione-Guerra, Javier; Cruz-Solbes, Ana S; Gonzalez Bonilla, Hilda; Estep, Jerry D; Guha, Ashrith; Bhimaraj, Arvind; Suarez, Erik E; Bruckner, Brian A; Torre-Amione, Guillermo; Park, Myung H; Trachtenberg, Barry H
The model for end-stage liver disease (MELD) has been used as a predictor of mortality after left ventricular assist device (LVAD) placement. However, improvement or worsening of MELD and how those changes affect outcomes is unknown. We performed a retrospective analysis of 244 patients implanted with a continuous flow (CF) LVAD. Patients were dichotomized at admission into low- or high-risk categories using a cutoff of MELD ≥ 19, and they were reclassified at day of implant forming four groups: Group LL (low to low, remained low risk), LH (low to high, worsened to high risk), HH (high to high, remained high risk), and HL (high to low, improved to low risk). Patients who improved to a low risk (group HL) had the same 1 year survival as those that remained low risk (group LL; 80% vs. 77%; p = 0.6). However, patients who were initially classified as low risk and worsened to a high risk (group LH) had a survival that was worse than those that were consistently high risk (group HH; 55% vs. 10%; p = 0.01). Model for end-stage liver disease reclassification after adjusting for commonly attributed risk factors remained an independent predictor for mortality, including patients classified as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 1 and 2. In conclusion, our MELD score reclassification is an independent and powerful predictor of mortality in patients undergoing LVAD implantation.
Durand, Marlene L; Ennis, Stephanie C; Baker, Joshua N; Camuso, Janice M; McEachern, Kathleen M; Kotton, Camille N; Lewis, Gregory D; Garcia, Jose P; MacGillivray, Thomas E
2017-02-01
This retrospective cohort study evaluated the effect of topical polymyxin-trimethoprim (poly) prophylaxis on the incidence of driveline infections (DLIs) in patients with continuous-flow left ventricular assist devices. All 84 cases implanted 2005-2014 with device support ≥30 days were reviewed; support ranged 1 m-5.2 yrs. Beginning 2008, poly was applied to the exit site with dressing changes. Sixty-five patients received poly (poly group) for duration of follow-up, 19 did not (no-poly); group baseline characteristics were similar. No patient developed side effects from poly. Nineteen DLIs (10 in no-poly) occurred; not using poly was a risk factor. 89% of poly group DLIs were superficial, 4 were culture-negative. DLI-related bacteremia occurred in 11% of no-poly group and 0% of poly group. Compared with no-poly, poly group demonstrated improved freedom from DLI by Kaplan-Meier analysis (P < 0.0001) and a 75% lower overall and 95% lower deep DLI incidence (P ≤ 0.001). Deep DLIs occurred in 31.6% of no-poly vs. 1.5% of poly patients (P = 0.0004), although mean support duration (1 yr) and % support >1 yr (38%) were similar. These findings, which should be confirmed with larger comparative studies, suggest that topical polymyxin-trimethoprim prophylaxis may be effective in preventing DLIs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Right Ventricular Hemodynamics in Patients with Pulmonary Hypertension
NASA Astrophysics Data System (ADS)
Browning, James; Fenster, Brett; Hertzberg, Jean; Schroeder, Joyce
2012-11-01
Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for characterization of blood flow in the right ventricle (RV), including calculation of vorticity and circulation, and qualitative visual assessment of coherent flow patterns. In this study, we investigate qualitative and quantitative differences in right ventricular hemodynamics between subjects with pulmonary hypertension (PH) and normal controls. Fifteen (15) PH subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine right ventricular diastolic function as well as pulmonary artery systolic pressure (PASP). Velocity vectors, vorticity vectors, and streamlines in the RV were visualized in Paraview and total RV Early (E) and Atrial (A) wave diastolic vorticity was quantified. Visualizations of blood flow in the RV are presented for PH and normal subjects. The hypothesis that PH subjects exhibit different RV vorticity levels than normals during diastole is tested and the relationship between RV vorticity and PASP is explored. The mechanics of RV vortex formation are discussed within the context of pulmonary arterial pressure and right ventricular diastolic function coincident with PH.
NASA Technical Reports Server (NTRS)
Erickson, H. H.; Stone, H. L.
1972-01-01
The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.
Recovery of Serum Cholesterol Predicts Survival After Left Ventricular Assist Device Implantation
Vest, Amanda R.; Kennel, Peter J.; Maldonado, Dawn; Young, James B.; Mountis, Maria M.; Naka, Yoshifumi; Colombo, Paolo C.; Mancini, Donna M.; Starling, Randall C.; Schulze, P. Christian
2017-01-01
Background Advanced systolic heart failure is associated with myocardial and systemic metabolic abnormalities, including low levels of total cholesterol and low-density lipoprotein. Low cholesterol and low-density lipoprotein have been associated with greater mortality in heart failure. Implantation of a left ventricular assist device (LVAD) reverses some of the metabolic derangements of advanced heart failure. Methods and Results A cohort was retrospectively assembled from 2 high-volume implantation centers, totaling 295 continuous-flow LVAD recipients with ≥2 cholesterol values available. The cohort was predominantly bridge-to-transplantation (67%), with median age of 59 years and 49% ischemic heart failure cause. Total cholesterol, low-density lipoprotein, high-density lipoprotein, and triglyceride levels all significantly increased after LVAD implantation (median values from implantation to 3 months post implantation 125–150 mg/dL, 67–85 mg/dL, 32–42 mg/dL, and 97–126 mg/dL, respectively). On Cox proportional hazards modeling, patients achieving recovery of total cholesterol levels, defined as a median or greater change from pre implantation to 3 months post-LVAD implantation, had significantly better unadjusted survival (hazard ratio, 0.445; 95% confidence interval, 0.212–0.932) and adjusted survival (hazard ratio, 0.241; 95% confidence interval, 0.092–0.628) than those without cholesterol recovery after LVAD implantation. The continuous variable of total cholesterol at 3 months post implantation and the cholesterol increase from pre implantation to 3 months were also both significantly associated with survival during LVAD support. Conclusions Initiation of continuous-flow LVAD support was associated with significant recovery of all 4 lipid variables. Patients with a greater increase in total cholesterol by 3 months post implantation had superior survival during LVAD support. PMID:27623768
Bartoli, Carlo R.; Rogers, Benjamin D.; Ionan, Constantine E.; Koenig, Steven C.; Pantalos, George M.
2013-01-01
OBJECTIVE Counterpulsation with an intraaortic balloon pump (IABP) has not achieved the same successes or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. METHODS In Yorkshire piglets (n=19, 13.0±0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7cc) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. RESULTS Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105±3bmp, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. CONCLUSIONS Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. PMID:24139614
Bartoli, Carlo R; Rogers, Benjamin D; Ionan, Constantine E; Pantalos, George M
2014-05-01
Counterpulsation with an intra-aortic balloon pump (IABP) has not achieved the same success or clinical use in pediatric patients as in adults. In a pediatric animal model, IABP efficacy was investigated to determine whether IABP timing with a high-fidelity blood pressure signal may improve counterpulsation therapy versus a low-fidelity signal. In Yorkshire piglets (n = 19; weight, 13.0 ± 0.5 kg) with coronary ligation-induced acute ischemic left ventricular failure, pediatric IABPs (5 or 7 mL) were placed in the descending thoracic aorta. Inflation and deflation were timed with traditional criteria from low-fidelity (fluid-filled) and high-fidelity (micromanometer) blood pressure signals during 1:1 support. Aortic, carotid, and coronary hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption was calculated from coronary sinus and arterial blood samples. Left ventricular myocardial blood flow and end-organ blood flow were measured with microspheres. Despite significant suprasystolic diastolic augmentation and afterload reduction at heart rates of 105 ± 3 beats per minute, left ventricular myocardial blood flow, myocardial oxygen consumption, the myocardial oxygen supply/demand relationship, cardiac output, and end-organ blood flow did not change. Statistically significant end-diastolic coronary, carotid, and aortic flow reversal occurred with IABP deflation. Inflation and deflation timed with a high-fidelity versus low-fidelity signal did not attenuate systemic flow reversal or improve the myocardial oxygen supply/demand relationship. Systemic end-diastolic flow reversal limited counterpulsation efficacy in a pediatric model of acute left ventricular failure. Adjustment of IABP inflation and deflation timing with traditional criteria and a high-fidelity blood pressure waveform did not improve IABP efficacy or attenuate flow reversal. End-diastolic flow reversal may limit the efficacy of IABP counterpulsation therapy in pediatric patients with traditional timing criteria. Investigation of alternative deflation timing strategies is warranted. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Effect of diastolic flow patterns on the function of the left ventricle
NASA Astrophysics Data System (ADS)
Seo, Jung Hee; Mittal, Rajat
2013-11-01
Direct numerical simulations are used to study the effect of intraventricular flow patterns on the pumping efficiency and the blood mixing and transport characteristics of the left ventricle. The simulations employ a geometric model of the left ventricle which is derived from contrast computed tomography. A variety of diastolic flow conditions are generated for a fixed ejection fraction in order to delineate the effect of flow patterns on ventricular performance. The simulations indicate that the effect of intraventricular blood flow pattern on the pumping power is physiologically insignificant. However, diastolic flow patterns have a noticeable effect on the blood mixing as well as the residence time of blood cells in the ventricle. The implications of these findings on ventricular function are discussed.
Inhaled Milrinone After Left Ventricular Assist Device Implantation.
Haglund, Nicholas A; Burdorf, Adam; Jones, Tara; Shostrom, Valerie; Um, John; Ryan, Timothy; Shillcutt, Sasha; Fischer, Patricia; Cox, Zachary L; Raichlin, Eugenia; Anderson, Daniel R; Lowes, Brian D; Dumitru, Ioana
2015-10-01
Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacokinetics (plasma milrinone levels), and cost data were collected.Mean age was 56 ± 9 years, 90% were male, and mean INTERMACS profile was 2.5 ± 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 ± 35.4, 111.3 ± 70.9, 135.9 ± 41.5, 205.0 ± 86.7, 176.8 ± 61.3 187.6 ± 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Downey, J M; Kirk, E S
1975-06-01
The mechanism whereby systole inhibits coronary blood flow was examined. A branch of the left coronary artery was maximally dilated with an adenosine infusion, and the pressure-flow relationship was obtained for beating and arrested states. The pressure-flow curve for the arrested state was shifted toward higher pressures and in the range of pressures above peak ventricular pressure was linear and parallel to that for the arrested state. Below this range the curve for the beating state converged toward that for the arrested state and was convex to the pressure axis. These results were compared with a model of the coronary vasculature that consisted of numerous parallel channels, each responding to local intramyocardial pressure by forming vascular waterfalls. When intramyocardial pressure in the model was assigned values from zero at the epicardium to peak ventricular pressure at the endocardium, pressure-flow curves similar to the experimental ones resulted. Thus, we conclude that systole inhibits coronary perfusion by the formation of vascular waterfalls and that the intramyocardial pressures responsible for this inhibition do not significantly exceed peak ventricular pressure.
Ventricular septal defect closure in a patient with achondroplasia.
Nakanishi, Keisuke; Kawasaki, Shiori; Amano, Atsushi
2017-01-01
Achondroplasia with co-morbid CHD is rare, as are reports of surgical treatment for such patients. We present the case of a 13-year-old girl with achondroplasia and ventricular septal defect. Her ventricular septal defect was surgically repaired focussing on the cardiopulmonary bypass flow, healing of the sternum, and her frail neck cartilage. The surgery and recovery were without complications.
Use of a Left Ventricular Assist Device as a Bridge to Transplantation in a Pediatric Patient
Frazier, O.H.; Bricker, J. Timothy; Macris, Michael P.; Cooley, Denton A.
1989-01-01
Despite many advances in heart transplantation and in mechanical circulatory support, the benefits of staged cardiac transplantation have not been extended to the pediatric transplant recipient, chiefly because implantable circulatory assist devices are still too large. Extracorporeal devices, however, can overcome this impediment. Here we report the 1st case, to our knowledge, in which an extracorporeal left ventricular assist device has been used in a child to support circulation prior to cardiac transplantation. The patient was a 9-year-old boy in New York Heart Association functional class IV, with congestive heart failure as a result of idiopathic biventricular cardiomegaly. In mid-May of 1987, while awaiting a suitable donor, he suffered severe oliguria after an episode of circulatory arrest. Therefore we decided to maintain his circulation—and consequently his peripheral organ function—with an extracorporeal left ventricular assist device. After establishing cardiopulmonary bypass under normothermia and without cardiac arrest, we established flow from the left ventricle through a 36-Fr wire-reinforced straight cannula to a Biomedicus BP-80 centrifugal force pump, with return to the proximal ascending aorta through a 28-Fr wire-reinforced straight cannula. The patient's hemodynamic course under subsequent mechanical circulatory support was remarkably stable, with controllable systemic hypertension and no evidence of hemolysis. Although cardiac activity was minimal and systemic blood flow nonpulsatile, the patient's renal, pulmonary, and hepatic functions improved, and his peripheral circulation was well preserved. After 12 hours of support, a donor heart became available, and a routine orthotopic cardiac transplant was performed. Upon removal, the left ventricular assist device showed a small amount of thrombus formation. The patient's postoperative recovery has been easily manageable, and 20 months after transplant he enjoys unrestricted physical activity. We conclude that an extracorporeal left ventricular assist device can be used as a bridge to cardiac transplantation in children. Moreover, this application of a continuous force centrifugal pump without adverse effect encourages the conclusion that long-term maintenance of terminal heart disease patients might be possible through development of small, implantable pumps with the potential of lower power requirements and reduced thrombogenesis. (Texas Heart Institute Journal 1989;16:46-50) PMID:15227237
Prototype continuous flow ventricular assist device supported on magnetic bearings.
Allaire, P E; Kim, H C; Maslen, E H; Olsen, D B; Bearnson, G B
1996-06-01
This article describes a prototype continuous flow pump (CFVAD2) fully supported in magnetic bearings. The pump performance was measured in a simulated adult human circulation system. The pump delivered 6 L/min of flow at 100 mm Hg of differential pressure head operating at 2,400 rpm in water. The pump is totally supported in 4 magnetic bearings: 2 radial and 2 thrust. Magnetic bearings offer the advantages of no required lubrication and large operating clearances. The geometry and other properties of the bearings are described. Bearing parameters such as load capacity and current gains are discussed. Bearing coil currents were measured during operation in air and water. The rotor was operated in various orientations to determine the actuator current gains. These values were then used to estimate the radial and thrust forces acting on the rotor in both air and water. Much lower levels of force were found than were expected, allowing for a very significant reduction in the size of the next prototype. Hemolysis levels were measured in the prototype pump and found not to indicate damage to the blood cells.
Schelhorn, Juliane; Neudorf, Ulrich; Schemuth, Haemi; Nensa, Felix; Nassenstein, Kai; Schlosser, Thomas W
2015-11-01
Patients with corrected tetralogy of Fallot (cToF) are prone to develop pulmonary regurgitation and right ventricular enlargement resulting in long-term complications, thus correct right ventricular volumetric monitoring is crucial. However, it remains controversial which cardiovascular magnetic resonance imaging (CMRI) slice orientation is most appropriate in cToF for the analysis of the right ventricular volume. To investigate which slice orientation is most suited for right ventricular volumetry in cToF we compared short-axis and axial slices, and furthermore we compared right ventricular data between CMRI and echocardiography. Thirty CMRI examinations of 27 patients with cToF were included retrospectively. Right ventricular end-diastolic (EDV) and end-systolic volume (ESV) were derived from short-axis and axial cine CMRI planes. Furthermore, pulmonary trunk forward flow in phase-contrast CMRI and right ventricular inner diastolic diameter in echocardiography (R VIDdiast) were measured. By Bland-Altman and variance analysis intra- and inter-observer agreement were assessed for cine CMRI data. By Pearson correlation CMRI cine and phase-contrast data and CMRI cine and echocardiographic data were compared. Intra- and inter-observer variability for right ventricular EDV were significantly lower in axial slices (P = 0.016, P = 0.010). For right ventricular ESV a trend towards a lower intra- and inter-observer variability in axial slices was found (P = 0.063, P = 0.138). Right ventricular stroke volume in short-axis (r = 0.872, P < 0.001) and in axial (r = 0.914, P < 0.001) planes correlated highly, respectively very highly with pulmonary trunk forward flow in phase-contrast CMRI. R VIDdiast correlated highly with right ventricular EDV assessed by short-axis and axial CMRI (P < 0.001, P < 0.001). Due to lower intra- and inter-observer variability, axial slices are recommended for right ventricular volumetry in cToF. © The Foundation Acta Radiologica 2014.
Tuo, Giulia; Volpe, Paolo; Buffi, Davide; De Robertis, Valentina; Marasini, Maurizio
2014-01-01
To describe the antenatal and neonatal echocardiographic morphology and flow pattern of the ductus arteriosus in patients with tetralogy of Fallot. We included patients with a prenatal diagnosis of tetralogy of Fallot between January 2006 and December 2012. Among the 52 fetuses with tetralogy of Fallot the severity of right ventricular outflow obstruction was considered mild in 32, moderate in 14, and severe in 6. In the mild right ventricular outflow obstruction group (n = 32) all had normal ductal morphology and flow pattern, eight (25%) elected for termination of pregnancy and two died in the neonatal period from extracardiac causes. In the moderate right ventricular outflow obstruction group (n = 14) the fetuses had a small ductus arteriosus with antegrade but abnormal flow velocity, one (7%) elected for termination of pregnancy. Immediately after birth the ductus arteriosus was very small or already closed at echocardiographic examination. Two out of 13 patients (15%) developed severe hypoxic spells and underwent modified Blalock-Taussig shunt during the neonatal period. Six fetuses were considered to have severe right ventricular outflow obstruction with flow reversal in the ductus arteriosus, three (50%) of whom elected for termination of pregnancy. The other three newborns underwent modified Blalock-Taussig shunt. In fetuses with tetralogy of Fallot, ductal diameter can be reduced even up to prenatal closure. Prenatal ductal morphology assessment may be useful for improving management of patients with moderate right ventricular outflow obstruction and small ductus arteriosus who may become cyanotic at birth. © 2013 Wiley Periodicals, Inc.
Flow-related Right Ventricular - Pulmonary Arterial Pressure Gradients during Exercise.
Wright, Stephen P; Opotowsky, Alexander R; Buchan, Tayler A; Esfandiari, Sam; Granton, John T; Goodman, Jack M; Mak, Susanna
2018-06-06
The assumption of equivalence between right ventricular and pulmonary arterial systolic pressure is fundamental to several assessments of right ventricular or pulmonary vascular hemodynamic function. Our aims were to 1) determine whether systolic pressure gradients develop across the right ventricular outflow tract in healthy adults during exercise, 2) examine the potential correlates of such gradients, and 3) consider the effect of such gradients on calculated indices of right ventricular function. Healthy untrained and endurance-trained adult volunteers were studied using right-heart catheterization at rest and during submaximal cycle ergometry. Right ventricular and pulmonary artery pressures were simultaneously transduced, and cardiac output was determined by thermodilution. Systolic pressures, peak and mean gradients, and indices of chamber, vascular, and valve function were analyzed offline. Summary data are reported as mean ± standard deviation or median [interquartile range]. No significant right ventricular outflow tract gradients were observed at rest (mean gradient = 4 [3-5] mmHg), and calculated effective orifice area was 3.6±1.0 cm2. Right ventricular systolic pressure increases during exercise were greater than that of pulmonary artery systolic pressure. Accordingly, mean gradients developed during light exercise (8 [7-9] mmHg) and increased during moderate exercise (12 [9-14] mmHg, p < 0.001). The magnitude of the mean gradient was linearly related to cardiac output (r2 = 0.70, p < 0.001). In healthy adults without pulmonic stenosis, systolic pressure gradients develop during exercise, and the magnitude is related to blood flow rate.
Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino
2018-01-01
Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Mechanical circulatory support in pediatrics.
Steffen, Robert J; Miletic, Kyle G; Schraufnagel, Dean P; Vargo, Patrick R; Fukamachi, Kiyotaka; Stewart, Robert D; Moazami, Nader
2016-05-01
End-stage heart failure affects thousands of children yearly and mechanical circulatory support is used at many points in their care. Extracorporeal membrane oxygenation supports both the failing heart and lungs, which has led to its use as an adjunct to cardiopulmonary resuscitation as well as in post-operative cardiogenic shock. Continuous-flow ventricular assist devices (VAD) have replaced pulsatile-flow devices in adults and early studies have shown promising results in children. The Berlin paracorporeal pulsatile VAD recently gained U.S. Food and Drug Administration approval and remains the only VAD approved in pediatrics. Failing univentricular hearts and other congenitally corrected lesions are new areas for mechanical support. Finding novel uses, improving durability, and minimizing complications are areas of growth in pediatric mechanical circulatory support.
Zhang, Y; Yuan, H Y; Liu, X B; Wen, S S; Xu, G; Cui, H J; Zhuang, J; Chen, J M
2018-06-01
As a result of right ventricular outflow tract reconstruction, which is the important and basic step of complex cardiac surgery, the blood flow of right ventricular outflow tract is unobstructed, while pulmonary valve regurgitation and right heart dysfunction could be happened. These problems are often ignored in early days, more and more cases of right heart dysfunction need clinical intervention, which is quite difficult and less effective. How to protect effectively the right ventricular function is the focus. At present main methods to protect the right ventricular function include trying to avoid or reduce length of right ventricular incision, reserving or rebuilding the function of the pulmonary valve, using growth potential material for surgery. The protection of the right ventricular function is a systemic project, it involves many aspects, single measures is difficult to provide complete protection, only the comprehensive use of various protection strategy, can help to improve the long-term prognosis.
Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist.
Kono, S; Nishimura, K; Nishina, T; Akamatsu, T; Komeda, M
2000-01-01
A magnetically suspended centrifugal pump (MSCP), developed for long-term ventricular assist, is reliable and durable because it has no shaft or seal. However, with nonvalve pumps such as a MSCP, regurgitation occurs when they accidentally stop without cannula clamping. We investigated the hemodynamics during temporary stoppage of a MSCP being used as a left ventricular assist system (LVAS), comparing two inflow cannulation sites. In four sheep (weight, 35-45 kg), microspheres were injected into the left main coronary artery to induce heart failure. An outflow cannula was sutured onto the descending aorta, and two inflow cannulae were inserted into the left atrium and the left ventricle. The MSCP was stopped with both the left ventricular cannula and left atrial cannula clamped, and the hemodynamics and P-V loops were recorded. Each cannula was then unclamped in order, and similar parameters were recorded. LVEDP increased at unclamping of the left ventricular cannula (ULVC), and rose further at unclamping of the left atrial cannula (ULAC). Aortic pressure did not change at ULVC, but decreased at ULAC. The effective systemic flow that subtracted the regurgitant flow through the MSCP from left ventricular output was half at ULVC and almost 0 at ULAC. When stopping centrifugal pumps without circuit clamping, hemodynamic deterioration is less at ULVC than at ULAC. This finding suggests that left ventricular inflow cannulation is recommended to allow more time in emergency situations.
Díaz-Arrieta, Gustavo; Mendoza-Hernández, María Elsa; Pacheco-Aranda, Erika; Rivas-Duro, Miguel; Robles-Parra, Héctor Manuel; Espinosa-Vázquez, Raúl Arturo; Hernández-Cabrera, Jorge
2010-01-01
In diabetic patients with chronic renal failure (CRF) treated with dialysis, the diastolic and systolic left ventricular dysfunction is frequent. The aim was to assess by echocardiography the prevalence of diastolic and systolic ventricular dysfunction in diabetic patients with CRF treated with continuous ambulatory peritoneal dialysis (CAPD). Sixty diabetic patients with CRF in CAPD were studied. The mean age was 54.5 +/- 12 years (27-78 years). The left ventricular filling pattern (LVFP) as a diastolic function parameter and left ventricular ejection fraction (LVEF) as a systolic function parameter were measured by transthoracic echocardiography. Descriptive statistical analysis was used. 27 (45 %) patients were women and 33 (55 %) were men. In 55 (91.7 %) left ventricular concentric hypertrophy was observed. Fifty-two patients (86.7 %) showed LVFP type I; three (5 %) had the type II; two (3.3 %) showed pseudonormal pattern and three (5 %) had a normal LVFP. The LVEF was 0.63 +/- 0.09 (CI = 0.41-0.82). Forty nine (81.7 %) patients had LVEF equal or greater than 0.55. The prevalence of diastolic left ventricular dysfunction was 95 % and the prevalence of systolic left ventricular dysfunction was 18.3%.
Gazmuri, Raúl J; Kaufman, Christopher L; Baetiong, Alvin; Radhakrishnan, Jeejabai
2016-01-01
Several characteristics of the ventricular fibrillation (VF) waveform have been found predictive of successful defibrillation and hypothesized to reflect the myocardial energy state. In an open-chest swine model of VF, we modeled "average CPR" using extracorporeal circulation (ECC) and assessed the time course of coronary blood flow, myocardial metabolism, and myocardial structure in relation to the amplitude spectral area (AMSA) of the VF waveform without artifacts related to chest compression. VF was induced and left untreated for 8 minutes in 16 swine. ECC was then started adjusting its flow to maintain a coronary perfusion pressure of 10 mmHg for 10 minutes. AMSA was calculated in the frequency domain and analyzed continuously with a 2.1 s timeframe and a Tukey window that moved ahead every 0.5 s. AMSA progressively declined during untreated VF. With ECC, AMSA increased from 7.0 ± 1.9 mV·Hz (at minute 8) to 12.8 ± 3.3 mV·Hz (at minute 14) (p < 0.05) without subsequent increase and showing a modest correlation with coronary blood flow of borderline statistical significance (r = 0.489, p = 0.0547). Myocardial energy measurements showed marked reduction in phosphocreatine and moderate reduction in ATP with increases in ADP, AMP, and adenosine along with myocardial lactate, all indicative of ischemia. Yet, ischemia did not resolve during ECC despite a coronary blood flow of ~ 30% of baseline. AMSA increased upon return of coronary blood flow during ECC. However, the maximal level was reached after ~ 6 minutes without further change. The significance of the findings for determining the optimal timing for delivering an electrical shock during resuscitation from VF remains to be further explored.
Detection of ventricular fibrillation from multiple sensors
NASA Astrophysics Data System (ADS)
Lindsley, Stephanie A.; Ludeman, Lonnie C.
1992-07-01
Ventricular fibrillation is a potentially fatal medical condition in which the flow of blood through the body is terminated due to the lack of an organized electric potential in the heart. Automatic implantable defibrillators are becoming common as a means for helping patients confronted with repeated episodes of ventricular fibrillation. Defibrillators must first accurately detect ventricular fibrillation and then provide an electric shock to the heart to allow a normal sinus rhythm to resume. The detection of ventricular fibrillation by using an array of multiple sensors to distinguish between signals recorded from single (normal sinus rhythm) or multiple (ventricular fibrillation) sources is presented. An idealistic model is presented and the analysis of data generated by this model suggests that the method is promising as a method for accurately and quickly detecting ventricular fibrillation from signals recorded from sensors placed on the epicardium.
Liu, Jie; Cao, Tie-Sheng; Yuan, Li-Jun; Duan, Yun-You; Yang, Yi-Lin
2006-05-16
Assessment of cardiac preload is important for clinical management of some emergencies related to hypovolemia. Effects of acute simulated hypovolemia on Doppler blood flow velocity indices of tricuspid valve (TV) and superior vena cava (SVC) were investigated in order to find sensitive Doppler indices for predicting right ventricular preload. Doppler flow patterns of SVC and TV in 12 healthy young men were examined by transthoracic echocardiography (TTE) during graded lower body negative pressure (LBNP) of up to -60 mm Hg which simulated acute hypovolemia. Peak velocities of all waves and their related ratios (SVC S/D and tricuspid E/A) were measured, calculated and statistically analyzed. Except for the velocity of tricuspid A wave, velocities of all waves and their related ratios declined during volume decentralization. Of all indices measured, the peak velocities of S wave and AR wave in SVC correlated most strongly with levels of LBNP (r = -0.744 and -0.771, p < 0.001). The S and AR velocities are of good values in assessing right ventricular preload. Monitoring SVC flow may provide a relatively noninvasive means to assess direct changes in right ventricular preload.
21 CFR 882.4060 - Ventricular cannula.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ventricular cannula. 882.4060 Section 882.4060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4060 Ventricular cannula. (a...
21 CFR 882.4060 - Ventricular cannula.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ventricular cannula. 882.4060 Section 882.4060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4060 Ventricular cannula. (a...
Zhang, Chuan; Zha, Dao-Gang; DU, Rong-Sheng; Hu, Feng; Li, Sheng-Hui; Wu, Xiao-Yuan; Liu, Yi-Li
2009-07-01
To assess the value of velocity vector imaging (VVI) and quantitative tissue velocity imaging (QTVI) in assessing left ventricular diastolic function of the dogs with acute myocardial ischemia. Six healthy mongrel dogs were subjected to ligation of the left circumflex artery or left anterior descending artery to induce coronary artery stenosis of varying degrees. The mean peak diastolic velocity (Em) of the ventricular walls around the mitral annulus was recorded with VVI or QTVI in the coronary blood flow. The left ventricular end diastolic pressure (LVEDP) was measured with pigtail catheter in the left ventricle. As the coronary blood flow decreased, LVEDP was gradually increased, and Em measured by VVI or QTVI were also gradually decreased. A good linear correlation was shown between Em measured by VVI or QTVI and LVEDP (r=-0.834, P<0.001, and r=-0.68, P<0.001, respectively). A significant difference was observed in the correlation coefficient between VVI and QTVI (Z=2.625, P=0.0087). VVI and QTVI both provide good noninvasive means for measuring left ventricular diastolic function. VVI, a new echocardiographic modality without angular dependence, is better than QTVI in evaluating left ventricular diastolic function.
Krams, R; Sipkema, P; Westerhof, N
1990-06-01
In this study on the isolated, maximally vasodilated, blood-perfused cat heart we investigated the relation between left ventricular developed pressure (delta Piv) and coronary oscillatory flow amplitude (diastolic minus systolic flow, delta F) at different levels of constant perfusion pressure (Pp). We hypothesized that the effect of cardiac contraction on the phasic flow results from the changing elastic properties of cardiac muscle. The coronary vessel compartment can, as can the left ventricular lumen compartment, be described by a time-varying elastance. This concept predicts that the effect of left ventricular pressure on delta F is small, whereas the effect of Pp is considerable. Both the waterfall model and the intramyocardial pump model predict the inverse. The relation between delta Piv and delta F at a Pp of 10 kPa is delta F = (4.71 +/- 3.08).delta Piv + 337 +/- 75 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 7); the relation between (constant levels of) Pp and delta F at a constant delta Piv of 10 kPa is delta F = 51.Pp + 211 (slope in ml.min-1.100 g-1.kPa-1 and intercept in ml.min-1.100 g-1; n = 6). The differences in slope are best predicted by the time-varying elastance concept.
Development and evaluation of endurance test system for ventricular assist devices.
Sumikura, Hirohito; Homma, Akihiko; Ohnuma, Kentaro; Taenaka, Yoshiyuki; Takewa, Yoshiaki; Mukaibayashi, Hiroshi; Katano, Kazuo; Tatsumi, Eisuke
2013-06-01
We developed a novel endurance test system that can arbitrarily set various circulatory conditions and has durability and stability for long-term continuous evaluation of ventricular assist devices (VADs), and we evaluated its fundamental performance and prolonged durability and stability. The circulation circuit of the present endurance test system consisted of a pulsatile pump with a small closed chamber (SCC), a closed chamber, a reservoir and an electromagnetic proportional valve. Two duckbill valves were mounted in the inlet and outlet of the pulsatile pump. The features of the circulation circuit are as follows: (1) the components of the circulation circuit consist of optimized industrial devices, giving durability; (2) the pulsatile pump can change the heart rate and stroke length (SL), as well as its compliance using the SCC. Therefore, the endurance test system can quantitatively reproduce various circulatory conditions. The range of reproducible circulatory conditions in the endurance test circuit was examined in terms of fundamental performance. Additionally, continuous operation for 6 months was performed in order to evaluate the durability and stability. The circulation circuit was able to set up a wide range of pressure and total flow conditions using the SCC and adjusting the pulsatile pump SL. The long-term continuous operation test demonstrated that stable, continuous operation for 6 months was possible without leakage or industrial device failure. The newly developed endurance test system demonstrated a wide range of reproducible circulatory conditions, durability and stability, and is a promising approach for evaluating the basic characteristics of VADs.
Shi, Jie; Stonnington, Cynthia M; Thompson, Paul M; Chen, Kewei; Gutman, Boris; Reschke, Cole; Baxter, Leslie C; Reiman, Eric M; Caselli, Richard J; Wang, Yalin
2015-01-01
Mild Cognitive Impairment (MCI) is a transitional stage between normal aging and dementia and people with MCI are at high risk of progression to dementia. MCI is attracting increasing attention, as it offers an opportunity to target the disease process during an early symptomatic stage. Structural magnetic resonance imaging (MRI) measures have been the mainstay of Alzheimer's disease (AD) imaging research, however, ventricular morphometry analysis remains challenging because of its complicated topological structure. Here we describe a novel ventricular morphometry system based on the hyperbolic Ricci flow method and tensor-based morphometry (TBM) statistics. Unlike prior ventricular surface parameterization methods, hyperbolic conformal parameterization is angle-preserving and does not have any singularities. Our system generates a one-to-one diffeomorphic mapping between ventricular surfaces with consistent boundary matching conditions. The TBM statistics encode a great deal of surface deformation information that could be inaccessible or overlooked by other methods. We applied our system to the baseline MRI scans of a set of MCI subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI: 71 MCI converters vs. 62 MCI stable). Although the combined ventricular area and volume features did not differ between the two groups, our fine-grained surface analysis revealed significant differences in the ventricular regions close to the temporal lobe and posterior cingulate, structures that are affected early in AD. Significant correlations were also detected between ventricular morphometry, neuropsychological measures, and a previously described imaging index based on fluorodeoxyglucose positron emission tomography (FDG-PET) scans. This novel ventricular morphometry method may offer a new and more sensitive approach to study preclinical and early symptomatic stage AD. Copyright © 2014 Elsevier Inc. All rights reserved.
Shi, Jie; Stonnington, Cynthia M.; Thompson, Paul M.; Chen, Kewei; Gutman, Boris; Reschke, Cole; Baxter, Leslie C.; Reiman, Eric M.; Caselli, Richard J.; Wang, Yalin
2014-01-01
Mild Cognitive Impairment (MCI) is a transitional stage between normal aging and dementia and people with MCI are at high risk of progression to dementia. MCI is attracting increasing attention, as it offers an opportunity to target the disease process during an early symptomatic stage. Structural magnetic resonance imaging (MRI) measures have been the mainstay of Alzheimer’s disease (AD) imaging research, however, ventricular morphometry analysis remains challenging because of its complicated topological structure. Here we describe a novel ventricular morphometry system based on the hyperbolic Ricci flow method and tensor-based morphometry (TBM) statistics. Unlike prior ventricular surface parameterization methods, hyperbolic conformal parameterization is angle-preserving and does not have any singularities. Our system generates a one-to-one diffeomorphic mapping between ventricular surfaces with consistent boundary matching conditions. The TBM statistics encode a great deal of surface deformation information that could be inaccessible or overlooked by other methods. We applied our system to the baseline MRI scans of a set of MCI subjects from the Alzheimer’s Disease Neuroimaging Initiative (ADNI: 71 MCI converters vs. 62 MCI stable). Although the combined ventricular area and volume features did not differ between the two groups, our fine-grained surface analysis revealed significant differences in the ventricular regions close to the temporal lobe and posterior cingulate, structures that are affected early in AD. Significant correlations were also detected between ventricular morphometry, neuropsychological measures, and a previously described imaging index based on fluorodeoxyglucose positron emission tomography (FDG-PET) scans. This novel ventricular morphometry method may offer a new and more sensitive approach to study preclinical and early symptomatic stage AD. PMID:25285374
Wei, Xufeng; Sanchez, Pablo G; Liu, Yang; Li, Tieluo; Watkins, A Claire; Wu, Zhongjun J; Griffith, Bartley P
2015-01-01
Despite the significant contribution of the Fontan procedure to the therapy of complex congenital heart diseases, many patients progress to failure of their Fontan circulation. The use of ventricular assist devices to provide circulatory support to these patients remains challenging. In the current study, a continuous axial-flow pump was used to support a univentricular Fontan circulation. A modified Fontan circulation (atrio-pulmonary connection) was constructed in six Yorkshire piglets (8-14 kg). A Dacron conduit (12 mm) with two branches was constructed to serve as a complete atrio-pulmonary connection without the use of cardiopulmonary bypass. The Impella pump was inserted into the conduit through an additional Polytetrafluoroethylene (PTFE) graft in five animals. Hemodynamic data were collected for 6 hours under the supported Fontan circulation. The control animal died after initiating the Fontan circulation independent of resuscitation. Four pump supported animals remained hemodynamically stable for 6 hours with pump speeds between 18,000 rpm and 22,000 rpm (P1-P3). Oxygen saturation was maintained between 95% and 100%. Normal organ perfusion was illustrated by blood gas analysis and biochemical assays. A continuous axial-flow pump can be used for temporal circulatory support to the failing Fontan circulation as "bridge" to heart transplantation or recovery.
Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device
NASA Astrophysics Data System (ADS)
Smith, P. Alex; Cohn, William; Metcalfe, Ralph
2017-11-01
A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.
Akintunde, Adeseye A.; Adebayo, Philip B.; Aremu, Ademola A.; Opadijo, Oladimeji G.
2013-01-01
Aim To determine the association of carotid atherosclerosis and right ventricular diastolic dysfunction (DD) among treated hypertensive Nigerian patients. Methods This was a single center cross-sectional study performed at the Cardiology Clinic of LAUTECH Teaching Hospital, Ogbomoso, Nigeria between January and December 2012. The study included 122 hypertensive Nigerians (mean age, 57.3 ± 14.7 years, 36.9% women). Patients’ clinical, demographic, and echocardiographic parameters were obtained. Diastolic dysfunction was assessed with the trans-tricuspid Doppler flow. Results Patients with DD were significantly older than those with normal diastolic function. Mean and maximum carotid intima media thickness measurements were significantly higher among patients with right ventricular DD than in those with normal diastolic function. Mean systolic blood pressure (148.3 ± 31.9 vs 128.0 ± 2.8 mm Hg, P = 0.049) and interventricular septal thickness in diastole (12.8 ± 2.3 vs 11.6 ± 2.8mm, P = 0.048) were significantly higher and tricuspid annular pulmonary systolic excursion (33.6 ± 4.9 vs 23.0 ± 4.2 mm, P = 0.035) was significantly lower in patients with right ventricular DD than in those with normal diastolic function. Carotid intima media thickness measurements were correlated with early trans-tricuspid Doppler flow and early transtricuspid diastolic flow/late right atrial transtricupsid diastolic flow ratio. Conclusion Right ventricular DD in hypertensive patients was significantly correlated with increased carotid atherosclerosis. Carotid intima media thickness measurements may therefore be a surrogate marker for DD in hypertensive subjects. PMID:24382850
21 CFR 870.3545 - Ventricular bypass (assist) device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ventricular bypass (assist) device. 870.3545 Section 870.3545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3545 Ventricular...
21 CFR 870.3545 - Ventricular bypass (assist) device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ventricular bypass (assist) device. 870.3545 Section 870.3545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3545 Ventricular...
Grupper, Avishay; Park, Soon J; Pereira, Naveen L; Schettle, Sarah D; Gerber, Yariv; Topilsky, Yan; Edwards, Brooks S; Daly, Richard C; Stulak, John M; Joyce, Lyle D; Kushwaha, Sudhir S
2015-08-01
Restrictive cardiomyopathy (RCM) patients have poor prognosis due to progressive heart failure characterized by impaired ventricular filling of either or both ventricles. The goal of this study was to evaluate the outcome of end-stage RCM patients after left ventricular assist device (LVAD) implantation and to determine factors that may be associated with improved survival. This investigation is a retrospective study of prospectively collected data that include 28 consecutive patients with end-stage RCM who received continuous-flow LVADs at the Mayo Clinic, Rochester, Minnesota. Outcome was assessed by survival with LVAD support until heart transplantation or all-cause mortality. The mean follow-up time post-LVAD implantation was 448 ± 425 days. The mean hospitalization time was 29 ± 19 days and was complicated mainly by post-operative right ventricular (RV) failure requiring short-term medical support. The short-term in-hospital mortality was 14%. Ten patients underwent heart transplantation with 100% survival post-transplant during the follow-up period. One-year survival for patients with LVADs without transplantation was 64%, and was not significantly different between amyloidosis and non-amyloidosis patients. Larger left ventricle (LV) end-diastolic and end-systolic dimensions were significantly associated with improved survival rates (RR = 0.94 and 0.95, p < 0.05, respectively), and left ventricular end-diastolic diameter (LVEDD) ≤46 mm was associated with increased mortality post-LVAD implantation. LVAD is a feasible, life-saving therapy for end-stage heart failure related to RCM, especially as a bridge to transplant and in patients with larger LV dimensions. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Topilsky, Yan; Hasin, Tal; Oh, Jae K; Borgeson, Daniel D; Boilson, Barry A; Schirger, John A; Clavell, Alfredo L; Frantz, Robert P; Tsutsui, Rayji; Liu, Mingya; Maltais, Simon; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J
2011-11-01
Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16-1.48]; P<0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22-18]; P=0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48-0.95]; P=0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21-13.3]; P=0.01). Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.
NASA Astrophysics Data System (ADS)
Tan, Sean Guo-Dong; Kim, Sangho; Leo, Hwa Liang
2016-06-01
Mechanical heart valve prostheses are often implanted in young patients due to their durability and long-term reliability. However, existing designs are known to induce elevated levels of blood damage and blood platelet activation. As a result, there is a need for patients to undergo chronic anti-coagulation treatment to prevent thrombosis, often resulting in bleeding complications. Furthermore, recent studies have suggested that the implantation of a mechanical prosthetic valve at the mitral position results in a significant alteration of the left ventricular flow field which may contribute to flow turbulence. This study proposes a bi-leaflet mechanical heart valve design (Bio-MHV) that mimics the geometry of a human mitral valve, with the aim of reducing turbulence levels in the left ventricle by replicating physiological flow patterns. An in vitro three-dimensional particle velocimetry imaging experiment was carried out to compare the hemodynamic performance of the Bio-MHV with that of the clinically established ATS valve. The Bio-MHV was found to replicate physiological left ventricular flow patterns and produced lower turbulence levels.
Halkar, Meghana; Nowacki, Amy S; Kendall, Kay; Efeovbokhan, Nephertiti; Gorodeski, Eiran Z; Moazami, Nader; Starling, Randall C; Young, James B; Lee, Sangjin; Tang, W H Wilson
2018-01-01
Psychosocial assessment of patients comprises an important element in the selection process of appropriate candidates for left ventricular assist device (LVAD) implantation. We sought to determine the association of the well-validated psychosocial assessment of candidates for transplantation (PACT) scale to clinical outcomes post-LVAD implantation. The PACT scale was used retrospectively to reconstruct psychosocial profiles of all patients who underwent a continuous-flow LVAD implantation for all indications at our institution between March 2008 and August 2012 (N = 230). Psychosocial elements including social support, psychological health, lifestyle factors, comprehension of the operation, and follow-up were evaluated. The primary outcome was overall survival, and the secondary outcomes were hospital readmission, pump thrombosis, hemolysis, gastrointestinal (GI) bleeding, and LVAD driveline infections. The mean age of patients was 55.3 years, with 83% being male; 58% (N = 135) were bridge to transplant and 42% (N = 95) were destination therapy. Up to 1-year post-LVAD implant, there were no statistical differences among the 5 PACT candidate groups in terms of survival ( P = .79), hospital readmissions ( P = .55), suspected or confirmed pump thrombosis ( P = .31), hemolysis ( P = .43), GI bleeding ( P = .71), or driveline infections ( P = .06). In this single-center retrospective review, post hoc reconstruction of psychosocial profiles using the PACT scale and independent assessment of postimplant outcomes, including survival and adverse events, did not show any association. However, given the small number of patients in the low score PACT groups as well as limited duration of follow-up, further studies are required to elucidate the association.
Deo, Salil V; Sharma, Vikas; Cho, Yang Hyun; Shah, Ishan K; Park, Soon J
2014-01-01
Aortic insufficiency (AI) may occur while supported on a left ventricular assist device (LVAD). We conducted a systematic review to determine the incidence, predictors, and consequences of AI during LVAD support. MEDLINE was searched for original studies presenting clinical data regarding patients who developed AI during LVAD implant. Seven observational studies (657 patients) were selected for review; 65% of patients underwent implantation with a continuous-flow device (Cf-LVAD). The incidence of AI was 25% (11-42%) (Support period: 412 ± 281 days). AI increased by 4% (1-6%) per month of support (p < 0.01). AI-positive patients were older at implant (weighted mean difference, 7.7 [4.3; 11.1]; p < 0.01). Female sex (0.002 ± 0.001; p = 0.01) and smaller body surface area (-0.003 ± 0.001 per m; p < 0.01) correlated with progressive AI. Destination therapy patients (odds ratio [OR], 5.3 [1.2, 24]; p = 0.02) and those with Cf-LVAD pumps were likely to develop AI (hazard ratio [HR], 2.2 [1.2, 3.8]; p < 0.01). A closed aortic valve was associated with AI (OR, 4.7 [1.9, 11.8]; p < 0.01). Survival was comparable in both cohorts (HR, 1.5 [0.81, 2.8]; p = 0.2). A significant number of patients develop de novo AI during LVAD support. Advanced age, longer support duration, continuous-flow pumps, and a closed aortic valve are associated with AI. Large cohort studies would improve our understanding of this condition.
Møller-Helgestad, Ole K; Poulsen, Christian B; Christiansen, Evald H; Lassen, Jens F; Ravn, Hanne B
2015-01-15
Cardiogenic shock as a complication to an acute myocardial infarction has an unacceptably high death rate that has not changed for the last 15years. Mortality is partly related to organ hypoperfusion and mechanical assist devices are used for the most severe cases but we do not know which assist device is the best option. Therefore, we have investigated how an IABP and an Impella®-pump influenced blood flow to the brain, heart and kidneys, in a closed-chest porcine model of severe left ventricular failure. 13 pigs were anesthetised and left ventricular failure was induced by occluding the proximal LAD for 45min followed by 30min of reperfusion. Blood flow was measured in the carotid artery, the LAD, and the renal artery. The Impella® and IABP were inserted via the femoral arteries, and the two devices were tested individually and combined after induction of heart failure. Carotid- (p=0.01) and renal blood flow (p=0.045) were higher on Impella®-support, compared to no support. None of the devices altered the blood flow in the LAD. Cardiac power output (p<0.005) and left ventricular work (p<0.00) were also higher on Impella®-support compared to no support. Haemodynamics and blood flow to the brain and kidneys were significantly better on Impella®-support, suggesting that the Impella® is superior to the IABP in a state of ischaemia induced left ventricular failure. These data, however, needs to be confirmed in a proper clinical trial with patients in cardiogenic shock. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Dekker, André L A J; Reesink, Koen D; van der Veen, Frederik H; van Ommen, G Vincent A; Geskes, Gijs G; Soemers, A Cecilia M; Maessen, Jos G
2003-04-01
Acute mitral regurgitation (MR) is present in 10% of patients presenting with cardiogenic shock. To stabilize these patients, intra-aortic balloon pumping (IABP) is recommended, but the mechanism of IABP support in these patients is unknown. This animal study was designed to describe the hemodynamic effect of intra-aortic balloon pumping during cardiogenic shock induced by acute MR. In eight calves, left ventricular pressure-volume loops, aortic and left atrial pressure, and aortic, carotid artery, and coronary blood flow were recorded. Acute MR (range 36%-79%) was created by placing a metal cage in the mitral valve. Hemodynamic data was obtained at control, during acute MR, and during acute MR with 1:1 IABP support. Acute MR caused a decrease in cardiac output (-32%, P = 0.018), blood pressure, and carotid artery flow, whereas left ventricular output (+127%, P = 0.018), end-diastolic volume, and left atrial pressure all significantly increased. Stroke work, ejection fraction, and coronary blood flow were not significantly changed, and no signs of ischemia were seen on the ECG. The IABP raised average cardiac output by 31% (P = 0.012) and significantly raised blood pressure and flow to the brain while decreasing systemic vascular resistance. Left ventricular function and mean coronary blood flow did not change, but diastolic coronary flow became more important as shown by the increase in diastolic fraction from 64% to 95%. (P = 0.028). Average MR dropped by 7.5% (P = 0.025). In conclusion, application of the IABP during acute MR lowers aortic impedance, resulting in less MR and more output toward the aorta without changing left ventricular function.
Djordjevic-Dikic, Ana; Beleslin, Branko; Stepanovic, Jelena; Giga, Vojislav; Tesic, Milorad; Dobric, Milan; Stojkovic, Sinisa; Nedeljkovic, Milan; Vukcevic, Vladan; Dikic, Nenad; Petrasinovic, Zorica; Nedeljkovic, Ivana; Tomasevic, Miloje; Vujisic-Tesic, Bosiljka; Ostojic, Miodrag
2011-05-01
The aim of this study was to evaluate the relation of basal and hyperemic coronary flow with myocardial functional improvement in patients with previous myocardial infarction undergoing elective percutaneous coronary intervention (PCI). Coronary flow was measured using transthoracic Doppler echocardiography in 50 patients (41 men; mean age, 53 ± 8 years) with previous myocardial infarction before, 24 hours, and 3 months after elective PCI. Diastolic deceleration time (DDT) was measured from the peak diastolic velocity to the point of intercept of initial decay slope with baseline. Coronary flow reserve (CFR) was calculated as the ratio of hyperemic to basal peak diastolic flow velocities. In comparison with patients without improvements in left ventricular function, patients with recovered left ventricular function had longer DDTs before angioplasty (841 ± 286 vs. 435 ± 80 msec, P < .001). CFR was significantly higher in recovered compared with nonrecovered patients (2.60 ± 0.70 vs. 2.16 ± 0.34, P = .034) 24 hours after PCI. Global and regional wall motion scores before PCI, end-diastolic and end-systolic volumes, and CFR 24 hours after PCI and DDT before PCI were univariate predictors of left ventricular functional recovery. By multivariate analysis, DDT and regional wall motion score before PCI were independent predictors of left ventricular recovery in the follow-up period (P = .003 and P = .007, respectively). In patients with previous myocardial infarction undergoing elective PCI, evaluation of basal coronary flow pattern and measurement of DDT before angioplasty may predict functional improvement of myocardium in the follow-up period and could be useful quantitative parameters in the evaluation of potential improvement in myocardial function. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Jang, Jaeseong; Ahn, Chi Young; Jeon, Kiwan; Choi, Jung-il; Lee, Changhoon; Seo, Jin Keun
2015-03-01
A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color Doppler echocardiography measurement. From 3D incompressible Navier- Stokes equation, a 2D incompressible Navier-Stokes equation with a mass source term is derived to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. For demonstrating a feasibility of the proposed method, we have performed numerical simulations of the forward problem and numerical analysis of the reconstruction method. First, we construct a 3D moving LV region having a specific stroke volume. To obtain synthetic intra-ventricular flows, we performed a numerical simulation of the forward problem of Navier-Stokes equation inside the 3D moving LV, computed 3D intra-ventricular velocity fields as a solution of the forward problem, projected the 3D velocity fields on the imaging plane and took the inner product of the 2D velocity fields on the imaging plane and scanline directional velocity fields for synthetic scanline directional projected velocity at each position. The proposed method utilized the 2D synthetic projected velocity data for reconstructing LV blood flow. By computing the difference between synthetic flow and reconstructed flow fields, we obtained the averaged point-wise errors of 0.06 m/s and 0.02 m/s for u- and v-components, respectively.
Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L.; Iaizzo, Paul A.; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin
2018-01-01
The aim of the present study is to characterize the hemodynamics of left ventricular (LV) geometries to examine the impact of trabeculae and papillary muscles (PMs) on blood flow using high performance computing (HPC). Five pairs of detailed and smoothed LV endocardium models were reconstructed from high-resolution magnetic resonance images (MRI) of ex-vivo human hearts. The detailed model of one LV pair is characterized only by the PMs and few big trabeculae, to represent state of art level of endocardial detail. The other four detailed models obtained include instead endocardial structures measuring ≥1 mm2 in cross-sectional area. The geometrical characterizations were done using computational fluid dynamics (CFD) simulations with rigid walls and both constant and transient flow inputs on the detailed and smoothed models for comparison. These simulations do not represent a clinical or physiological scenario, but a characterization of the interaction of endocardial structures with blood flow. Steady flow simulations were employed to quantify the pressure drop between the inlet and the outlet of the LVs and the wall shear stress (WSS). Coherent structures were analyzed using the Q-criterion for both constant and transient flow inputs. Our results show that trabeculae and PMs increase the intra-ventricular pressure drop, reduce the WSS and disrupt the dominant single vortex, usually present in the smoothed-endocardium models, generating secondary small vortices. Given that obtaining high resolution anatomical detail is challenging in-vivo, we propose that the effect of trabeculations can be incorporated into smoothed ventricular geometries by adding a porous layer along the LV endocardial wall. Results show that a porous layer of a thickness of 1.2·10−2 m with a porosity of 20 kg/m2 on the smoothed-endocardium ventricle models approximates the pressure drops, vorticities and WSS observed in the detailed models. PMID:29760665
Spranger, Marty D.; Kaur, Jasdeep; Sala-Mercado, Javier A.; Krishnan, Abhinav C.; Abu-Hamdah, Rania; Alvarez, Alberto; Machado, Tiago M.; Augustyniak, Robert A.
2017-01-01
Increases in myocardial oxygen consumption during exercise mainly occur via increases in coronary blood flow (CBF) as cardiac oxygen extraction is high even at rest. However, sympathetic coronary constrictor tone can limit increases in CBF. Increased sympathetic nerve activity (SNA) during exercise likely occurs via the action of and interaction among activation of skeletal muscle afferents, central command, and resetting of the arterial baroreflex. As SNA is heightened even at rest in subjects with hypertension (HTN), we tested whether HTN causes exaggerated coronary vasoconstriction in canines during mild treadmill exercise with muscle metaboreflex activation (MMA; elicited by reducing hindlimb blood flow by ~60%) thereby limiting increases in CBF and ventricular performance. Experiments were repeated after α1-adrenergic blockade (prazosin; 75 µg/kg) and in the same animals following induction of HTN (modified Goldblatt 2K1C model). HTN increased mean arterial pressure from 97.1 ± 2.6 to 132.1 ± 5.6 mmHg at rest and MMA-induced increases in CBF, left ventricular dP/dtmax, and cardiac output were markedly reduced to only 32 ± 13, 26 ± 11, and 28 ± 12% of the changes observed in control. In HTN, α1-adrenergic blockade restored the coronary vasodilation and increased in ventricular function to the levels observed when normotensive. We conclude that exaggerated MMA-induced increases in SNA functionally vasoconstrict the coronary vasculature impairing increases in CBF, which limits oxygen delivery and ventricular performance in HTN. NEW & NOTEWORTHY We found that metaboreflex-induced increases in coronary blood flow and ventricular contractility are attenuated in hypertension. α1-Adrenergic blockade restored these parameters toward normal levels. These findings indicate that the primary mechanism mediating impaired metaboreflex-induced increases in ventricular function in hypertension is accentuated coronary vasoconstriction. Listen to this article’s corresponding podcast at http://ajpheart.podbean.com/e/metaboreflex-induced-functional-coronary-vasoconstriction/. PMID:27769997
Traumatic Brain Injury-Induced Ependymal Ciliary Loss Decreases Cerebral Spinal Fluid Flow
Xiong, Guoxiang; Elkind, Jaclynn A.; Kundu, Suhali; Smith, Colin J.; Antunes, Marcelo B.; Tamashiro, Edwin; Kofonow, Jennifer M.; Mitala, Christina. M.; Stein, Sherman C.; Grady, M. Sean; Einhorn, Eugene; Cohen, Noam A.
2014-01-01
Abstract Traumatic brain injury (TBI) afflicts up to 2 million people annually in the United States and is the primary cause of death and disability in young adults and children. Previous TBI studies have focused predominantly on the morphological, biochemical, and functional alterations of gray matter structures, such as the hippocampus. However, little attention has been given to the brain ventricular system, despite the fact that altered ventricular function is known to occur in brain pathologies. In the present study, we investigated anatomical and functional alterations to mouse ventricular cilia that result from mild TBI. We demonstrate that TBI causes a dramatic decrease in cilia. Further, using a particle tracking technique, we demonstrate that cerebrospinal fluid flow is diminished, thus potentially negatively affecting waste and nutrient exchange. Interestingly, injury-induced ventricular system pathology resolves completely by 30 days after injury as ependymal cell ciliogenesis restores cilia density to uninjured levels in the affected lateral ventricle. PMID:24749541
Sharif, Dawod; Abu-Salem, Mira; Sharif-Rasslan, Amal; Rosenschein, Uri
2017-10-01
Patients with acute ST-elevation myocardial infarction (STEMI) and increased platelet count treated by fibrinolysis have worse outcomes. The aim of this study was to test the hypothesis that platelet blood count at admission in patients with acute STEMI treated by primary percutaneous coronary intervention affects coronary flow, myocardial perfusion and recovery of left ventricular systolic function. A total of 174 patients presenting with acute anterior STEMI and treated with primary percutaneous coronary intervention were included and divided into subgroups of admission platelet blood count of <200 K, 200-300 K, 300-400 K and >400 K. Evaluation of coronary artery flow and myocardial blush grade was performed according to the TIMI criteria. Electrocardiographic ST elevation resolution post-primary percutaneous coronary intervention was evaluated. Doppler echocardiographic evaluation of left anterior descending coronary artery velocities early and late after primary percutaneous coronary intervention and assessment of left ventricular ejection fraction and wall motion score index (WMSI) of left ventricular and left anterior descending coronary artery territory were performed. Post-primary percutaneous coronary intervention TIMI, myocardial blush grade and ST elevation resolution were similar in all groups. Patients with platelet counts <200 K had higher peak diastolic left anterior descending coronary artery velocity both early and late after primary percutaneous coronary intervention, and higher prevalence of left anterior descending coronary artery velocity deceleration time exceeding 600 ms, (45.5% vs. 40%, P<0.05). Patients with platelet counts >400 K presented with worse left ventricular ejection fraction, left ventricular WMSI and left anterior descending coronary artery WMSI, and before discharge this subgroup had worse left ventricular WMSI and left anterior descending coronary artery WMSI, P<0.01. Patients with anterior STEMI treated by primary percutaneous coronary intervention with lower admission platelet count had higher left anterior descending coronary artery diastolic velocities, better myocardial perfusion with more patients having left anterior descending coronary artery-descending coronary artery velocity deceleration time >600 ms. Patients with higher platelet counts had lower left ventricular systolic function both at admission and before discharge.
Dissociation of end systole from end ejection in patients with long-term mitral regurgitation.
Brickner, M E; Starling, M R
1990-04-01
To determine whether left ventricular (LV) end systole and end ejection uncouple in patients with long-term mitral regurgitation, 59 patients (22 control patients with atypical chest pain, 21 patients with aortic regurgitation, and 16 patients with mitral regurgitation) were studied with micromanometer LV catheters and radionuclide angiograms. End systole was defined as the time of occurrence (Tmax) of the maximum time-varying elastance (Emax), and end ejection was defined as the time of occurrence of minimum ventricular volume (minV) and zero systolic flow as approximated by the aortic dicrotic notch (Aodi). The temporal relation between end systole and end ejection in the control patients was Tmax (331 +/- 42 [SD] msec), minV (336 +/- 36 msec), and then, zero systolic flow (355 +/- 23 msec). This temporal relation was maintained in the patients with aortic regurgitation. In contrast, in the patients with mitral regurgitation, the temporal relation was Tmax (266 +/- 49 msec), zero systolic flow (310 +/- 37 msec, p less than 0.01 vs. Tmax), and then, minV (355 +/- 37 msec, p less than 0.001 vs. Tmax and p less than 0.01 vs. Aodi). Additionally, the average Tmax occurred earlier in the patients with mitral regurgitation than in the control patients and patients with aortic regurgitation (p less than 0.01, for both), whereas the average time to minimum ventricular volume was similar in all three patient groups. Moreover, the average time to zero systolic flow also occurred earlier in the patients with mitral regurgitation than in the control patients (p less than 0.01) and patients with aortic regurgitation (p less than 0.05). Because of the dissociation of end systole from minimum ventricular volume in the patients with mitral regurgitation, the end-ejection pressure-volume relations calculated at minimum ventricular volume did not correlate (r = -0.09), whereas those calculated at zero systolic flow did correlate (r = 0.88) with the Emax slope values. We conclude that end ejection, defined as minimum ventricular volume, dissociates from end systole in patients with mitral regurgitation because of the shortened time to LV end systole in association with preservation of the time to LV end ejection due to the low impedance to ejection presented by the left atrium. Therefore, pressure-volume relations calculated at minimum ventricular volume might not be useful for assessing LV chamber performance in some patients with mitral regurgitation.
Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device.
Burgreen, Greg W; Loree, Howard M; Bourque, Kevin; Dague, Charles; Poirier, Victor L; Farrar, David; Hampton, Edward; Wu, Z Jon; Gempp, Thomas M; Schöb, Reto
2004-10-01
The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of physiological operating conditions. The HeartMate III is a centrifugal flow pump with a magnetically suspended rotor. The complete pump was analyzed using computational fluid dynamics (CFD) analysis and experimental particle imaging flow visualization (PIFV). A comparison of CFD predictions to experimental imaging shows good agreement. Both CFD and experimental PIFV confirmed well-behaved flow fields in the main components of the HeartMate III pump: inlet, volute, and outlet. The HeartMate III is shown to exhibit clean flow features and good surface washing across its entire operating range.
Vortex Formation Time is Not an Index of Ventricular Function
Vlachos, Pavlos P.; Little, William C.
2015-01-01
The diastolic intraventricular ring vortex formation and pinch-off process may provide clinically useful insights into diastolic function in health and disease. The vortex ring formation time (FT) concept, based on hydrodynamic experiments dealing with unconfined (large tank) flow, has attracted considerable attention and popularity. Dynamic conditions evolving within the very confined space of a filling, expansible ventricular chamber with relaxing and rebounding viscoelastic muscular boundaries, diverge from unconfined (large tank) flow and encompass rebounding walls’ suction and myocardial relaxation. Indeed, clinical/physiological findings seeking validation in vivo failed to support the notion that FT is an index of normal/abnormal diastolic ventricular function. Therefore, FT as originally proposed cannot and should not be utilized as such an index. Evidently, physiologically accurate models accounting for coupled hydrodynamic and (patho)physiological myocardial wall interactions with the intraventricular flow are still needed to enhance our understanding and yield diastolic function indices useful and reliable in the clinical setting. PMID:25609509
Nascimbene, Angelo; Hernandez, Ruben; George, Joggy K.; Parker, Anita; Bergeron, Angela L.; Pradhan, Subhashree; Vijayan, K. Vinod; Civitello, Andrew; Simpson, Leo; Nawrot, Maria; Lee, Vei-Vei; Mallidi, Hari R.; Delgado, Reynolds M.; Dong, Jing Fei; Frazier, O.H.
2014-01-01
BACKGROUND Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. METHODS We enrolled 20 patients undergoing implantation of the HeartMate II LVAD and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. RESULTS During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm (n=1), non–ST-elevation myocardial infarction (n=2), arterial thrombosis (n=2), gastrointestinal bleeding (n=2), and stroke (n=3). Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11%±1.26 vs 0.69±0.46, P=0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39%±1.22 at discharge and then leveled to 1.97%±1.25 at 3-month follow-up. Importantly, patients who developed an adverse event had significantly higher levels of PS+ microparticles than did patients with no events (3.82%±1.17 vs 1.57%±0.59, P<0.001), even though the 2 patient groups did not markedly differ in other clinical and hematologic parameters. CONCLUSIONS Our results suggest that an elevation of PS+ microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events. PMID:24656391
Smolich, Joseph J
2014-02-15
Although a reduction in lung liquid volume increases fetal pulmonary blood flow, the changes in central flow patterns that sustain this increased pulmonary perfusion are unknown. To address this issue, eight anesthetized late-gestation fetal sheep were instrumented with pulmonary trunk (PT), ductus arteriosus (DA), and left pulmonary artery (PA) micromanometer catheters and transit-time flow probes, with blood flow profile and wave intensity analyses performed at baseline and after withdrawal of lung liquid via an endotracheal tube. Reducing lung liquid volume by 19 ± 6 ml/kg (mean ± SD) augmented right ventricular power by 34% (P < 0.001), with distribution of an accompanying increase in mean PT blood flow (245 ± 63 ml/min, P < 0.001) to the lungs (169 ± 91 ml/min, P = 0.001) and across the DA (77 ± 92 ml/min, P = 0.04). However, although PT and DA flow increments were confined to systole and were related to an increased magnitude of flow-increasing, forward-running compression waves, the rise in PA flow spanned both systole (108 ± 66 ml/min) and diastole (61 ± 32 ml/min). Flow profile analysis showed that the step-up in PA diastolic flow was associated with diminished PA diastolic backflow and accompanied by a lesser degree of diastolic right-to-left DA shunting. These data suggest that an increased pulmonary blood flow after reduction of lung liquid volume is associated with substantial changes in PT-DA-PA interactions and underpinned by two main factors: 1) enhanced right ventricular pump function that increases PA systolic inflow and 2) decreased PA diastolic backflow that arises from a fundamental change in PA reservoir function, thereby resulting in greater passage of systolic inflow through the lungs.
Weymann, Alexander; Patil, Nikhil P; Sabashnikov, Anton; Mohite, Phrashant N; Garcia Saez, Diana; Bireta, Christian; Wahlers, Thorsten; Karck, Matthias; Kallenbach, Klaus; Ruhparwar, Arjang; Fatullayev, Javid; Amrani, Mohamed; De Robertis, Fabio; Bahrami, Toufan; Popov, Aron-Frederik; Simon, Andre R
2015-04-01
The purpose of this study was to evaluate the effects and outcome of continuous-flow left ventricular assist device (cf-LVAD) therapy in patients with preoperative acute hepatic failure. The study design was a retrospective review of prospectively collected data. Included were 42 patients who underwent cf-LVAD implantation (64.3% HeartMate II, 35.7% HeartWare) between July 2007 and May 2013 with preoperative hepatic failure defined as elevation of greater than or equal to two liver function parameters above twice the upper normal range. Mean patient age was 35 ± 12.5 years, comprising 23.8% females. Dilated cardiomyopathy was present in 92.9% of patients (left ventricular ejection fraction 17.3 ± 5.9%). Mean support duration was 511 ± 512 days (range: 2-1996 days). Mean preoperative laboratory parameters for blood urea nitrogen, serum creatinine, total bilirubin, and alanine aminotransferase were 9.5 ± 5.4 mg/dL, 110.3 ± 42.8 μmol/L, 51.7 ± 38.3 mmol/L, and 242.1 ± 268.6 U/L, respectively. All parameters decreased significantly 1 month postoperatively. The mean preoperative modified Model for Endstage Liver Disease excluding international normalized ratio score was 16.03 ± 5.57, which improved significantly after cf-LVAD implantation to 10.62 ± 5.66 (P < 0.001) at 7 days and 5.83 ± 4.98 (P < 0.001) at 30 days postoperatively. One-year and 5-year survival was 75.9 and 48.1%, respectively. 21.4% of the patients underwent LVAD explantation for myocardial recovery, 16.7% were successfully transplanted, and 7.1% underwent LVAD exchange for device failure over the follow-up period. Patients with preexisting acute hepatic failure are reasonable candidates for cf-LVAD implantation, with excellent rates of recovery and survival, suggesting that cf-LVAD therapy should not be denied to patients merely on grounds of "preoperative elevated liver enzymes/hepatopathy." Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Sacco, Federica; Paun, Bruno; Lehmkuhl, Oriol; Iles, Tinen L; Iaizzo, Paul A; Houzeaux, Guillaume; Vázquez, Mariano; Butakoff, Constantine; Aguado-Sierra, Jazmin
2018-06-11
Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches employ smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band and papillary muscles (PMs). Four paired detailed and smoothed RV endocardium models (two male and two female) were reconstructed from ex-vivo human hearts high-resolution magnetic resonance images (MRI). Detailed models include structures with ≥1 mm 2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics (CFD) simulations with steady and transient inflows, using high performance computing (HPC). The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress (WSS). Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the WSS and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity. This article is protected by copyright. All rights reserved.
Manson, Amy; Poyade, Matthieu; Rea, Paul
2015-10-19
The use of computer-aided learning in education can be advantageous, especially when interactive three-dimensional (3D) models are used to aid learning of complex 3D structures. The anatomy of the ventricular system of the brain is difficult to fully understand as it is seldom seen in 3D, as is the flow of cerebrospinal fluid (CSF). This article outlines a workflow for the creation of an interactive training tool for the cerebral ventricular system, an educationally challenging area of anatomy. This outline is based on the use of widely available computer software packages. Using MR images of the cerebral ventricular system and several widely available commercial and free software packages, the techniques of 3D modelling, texturing, sculpting, image editing and animations were combined to create a workflow in the creation of an interactive educational and training tool. This was focussed on cerebral ventricular system anatomy, and the flow of cerebrospinal fluid. We have successfully created a robust methodology by using key software packages in the creation of an interactive education and training tool. This has resulted in an application being developed which details the anatomy of the ventricular system, and flow of cerebrospinal fluid using an anatomically accurate 3D model. In addition to this, our established workflow pattern presented here also shows how tutorials, animations and self-assessment tools can also be embedded into the training application. Through our creation of an established workflow in the generation of educational and training material for demonstrating cerebral ventricular anatomy and flow of cerebrospinal fluid, it has enormous potential to be adopted into student training in this field. With the digital age advancing rapidly, this has the potential to be used as an innovative tool alongside other methodologies for the training of future healthcare practitioners and scientists. This workflow could be used in the creation of other tools, which could be developed for use not only on desktop and laptop computers but also smartphones, tablets and fully immersive stereoscopic environments. It also could form the basis on which to build surgical simulations enhanced with haptic interaction.
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Shu, Fangjun; Vandenberghe, Stijn; Brackett, Jaclyn; Antaki, James F
2015-09-01
Rotodynamic blood pumps (also known as rotary or continuous flow blood pumps) are commonly evaluated in vitro under steady flow conditions. However, when these devices are used clinically as ventricular assist devices (VADs), the flow is pulsatile due to the contribution of the native heart. This study investigated the influence of this unsteady flow upon the internal hemodynamics of a centrifugal blood pump. The flow field within the median axial plane of the flow path was visualized with particle image velocimetry (PIV) using a transparent replica of the Levacor VAD. The replica was inserted in a dynamic cardiovascular simulator that synchronized the image acquisition to the cardiac cycle. As compared to steady flow, pulsatile conditions produced periodic, transient recirculation regions within the impeller and separation in the outlet diffuser. Dimensional analysis revealed that the flow characteristics could be uniquely described by the non-dimensional flow coefficient (Φ) and its time derivative ([Formula: see text]), thereby eliminating impeller speed from the experimental matrix. Four regimes within the Φ-[Formula: see text] plane were found to classify the flow patterns, well-attached or disturbed. These results and methods can be generalized to provide insights for both design and operation of rotodynamic blood pumps for safety and efficacy.
Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings.
Allaire, P E; Kim, H C; Maslen, E H; Olsen, D B; Bearnson, G B
1996-05-01
This article describes a prototype continuous flow pump (CFVAD2) fully supported in magnetic bearings. The pump performance was measured in a simulated adult human circulation system. The pump delivered 6 L/min of flow at 100 mm Hg of differential pressure head operating at 2,400 rpm in water. The pump is totally supported in 4 magnetic bearings: 2 radial and 2 thrust. Magnetic bearings offer the advantages of no required lubrication and large operating clearances. The geometry and other properties of the bearings are described. Bearing parameters such as load capacity and current gains are discussed. Bearing coil currents were measured during operation in air and water. The rotor was operated in various orientations to determine the actuator current gains. These values were then used to estimate the radial and thrust forces acting on the rotor in both air and water. Much lower levels of force were found than were expected, allowing for a very significant reduction in the size of the next prototype. Hemolysis levels were measured in the prototype pump and found not to indicate damage to the blood cells. © 1996 International Society for Artificial Organs.
Gaffey, Ann C; Chen, Carol W; Chung, Jennifer J; Han, Jason; Bermudez, Christian A; Wald, Joyce; Atluri, Pavan
2018-02-13
Continuous-flow left ventricular assist devices (CF-LVAD) have become the standard of care for patients with end stage heart failure. Device reliability has increased, bringing the potential for VAD, compared to transplant, into debate. However, complications continue to limit VADs as first line therapy. Bleeding is a major morbidity. A debate exists as to the difference in bleeding profile between the major centrifugal and axial flow devices. We hypothesized that there would be similar adverse bleeding event profiles between the 2 major CF-LVADs. We retrospectively investigated isolated CF LVADs performed at our institution between July 2010 and July 2015: HeartMateII (HMII, n = 105) and HeartWare (HVAD, n = 34). We reviewed demographic, perioperative and short- and long-term outcomes. There was no significant difference in demographics or comorbidities. There was a low incidence of gastrointestinal (GI) bleed 3.9% in HMII and 2.9% in HVAD (p = 0.78). Preoperatively, the cohorts did not differ in coagulation measures (p = 0.95). Within the post-operative period, there was no difference in product transfusion: red blood cells (p = 0.10), fresh frozen plasma (p = 0.19), and platelets (p = 0.89). Post-operatively, a higher but not significantly different number of HMII patients returned to the operating room for bleeding (n = 27) compared to HVAD (n = 6, p = 0.35). There was no difference in rates of stroke (p = 0.65), re-intubation (p = 0.60), driveline infection (p = 0.05), and GI bleeding (p = 0.31). The patients had equivalent ICU LOS (p = 0.86) and index hospitalization LOS (p = 0.59). We found no difference in the rate of bleeding complications between the current commercially available axial and centrifugal flow devices.
Rossano, Joseph W; Lorts, Angela; VanderPluym, Christina J; Jeewa, Aamir; Guleserian, Kristine J; Bleiweis, Mark S; Reinhartz, Olaf; Blume, Elizabeth D; Rosenthal, David N; Naftel, David C; Cantor, Ryan S; Kirklin, James K
2016-05-01
Continuous-flow (CF) ventricular assist devices (VADs) have largely replaced pulsatile-flow VADs in adult patients. However, there are few data on CF VADs among pediatric patients. In this study we aimed to describe the overall use, patients' characteristics and outcomes of CF VADs in this population. The Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS) is a national registry for U.S. Food and Drug Adminstration (FDA)-approved VADs in patients <19 years of age. Patients undergoing placement of durable CF VADs between September 2012 and June 2015 were included and outcomes were compared with those of adults from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). CF VADs were implanted in 109 patients at 35 hospitals. The median age at implantation was 15 years (2.8 to 18.9 years) and median weight was 62 kg (range 16 to 141 kg). The underlying disease was cardiomyopathy in 89 (82%) patients. The INTERMACS level at time of implant was Level 1 in 20 (19%), Level 2 in 64 (61%) and Levels 3 to 7 in 21 (20%) patients. Most were implanted as LVADs (n = 102, 94%). Median duration of support was 2.3 months (range <1 day to 28 months). Serious adverse event rates were low, including neurologic dysfunction (early event rate 4.1 per 100 patient-months with 2 late events). Competing outcomes analysis at 6 months post-implant indicated 61% transplanted, 31% alive with device in place and 8% death before transplant. These outcomes compared favorably with the 3,894 adults supported with CF VADs as a bridge to transplant. CF VADs are commonly utilized in older children and adolescents, with excellent survival rates. Further study is needed to understand impact of patient and device characteristics on outcomes in pediatric patients. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Aquilano, Giulia; Galletti, Silvia; Aceti, Arianna; Vitali, Francesca; Faldella, Giacomo
2014-06-21
Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4-5 cmH2O) because they developed RDS within the first 24-72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH2O, Plow 4-5 cmH2O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO2 levels after bi-level CPAP ventilation was observed; pCO2 variations did not correlate with modifications of central blood flow (LVO: ρ=0.11, p=0,657; RVO: ρ=-0.307, p=0.216; SVC: ρ=-0.13, p=0.197). Central blood flow doesn't change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants.
Acute control of pulmonary regurgitation with a balloon "valve". An experimental investigation.
Siwek, L G; Applebaum, R E; Jones, M; Clark, R E
1985-09-01
Operations for certain congenital cardiac lesions can produce pulmonary regurgitation. Pulmonary regurgitation contributes to right ventricular dysfunction, which may cause early postoperative morbidity and mortality. To ameliorate the problems of pulmonary regurgitation during the early postoperative period, we evaluated a method for its acute control. Complete pulmonary valvectomy was performed utilizing inflow occlusion in eight sheep. A catheter with a 15 ml spherical balloon was positioned in the pulmonary arterial trunk; its inflation and deflation were regulated by an intra-aortic balloon pump unit. Blood flow from the pulmonary arterial trunk and forward and regurgitant fraction were determined from electromagnetic flow transducer recordings. The regurgitant fraction with uncontrolled pulmonary regurgitation was 38% +/- 3% (forward flow = 42 +/- 5 ml/beat and regurgitant flow = 16 +/- 2 ml/beat). Inflation of the balloon during diastole was timed to completely eliminate pulmonary regurgitation. This balloon control of pulmonary regurgitation increased pulmonary arterial diastolic pressure from 12 +/- 1 to 17 +/- 1 mm Hg (p less than 0.0001) and decreased pulmonary arterial systolic pressure from 31 +/- 3 to 27 +/- 1 mm Hg (p = 0.06). Pulmonary arterial pulse pressure decreased from 19 +/- 3 to 9 +/- 1 mm Hg (p less than 0.003). Elimination of pulmonary regurgitation decreased right ventricular stroke volume (25 +/- 3 versus 42 +/- 5 ml/beat, p less than 0.0002) and resulted in a 46% reduction in right ventricular stroke work (5.0 +/- 0.6 versus 9.4 +/- 1.0 gm-m/beat, p less than 0.001) with no change in net forward pulmonary artery flow. Thus, acute pulmonary regurgitation can be controlled and this control improves overall hemodynamic status and decreases right ventricular work.
Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D
2011-12-01
Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.
A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure.
Mehra, Mandeep R; Naka, Yoshifumi; Uriel, Nir; Goldstein, Daniel J; Cleveland, Joseph C; Colombo, Paolo C; Walsh, Mary N; Milano, Carmelo A; Patel, Chetan B; Jorde, Ulrich P; Pagani, Francis D; Aaronson, Keith D; Dean, David A; McCants, Kelly; Itoh, Akinobu; Ewald, Gregory A; Horstmanshof, Douglas; Long, James W; Salerno, Christopher
2017-02-02
Continuous-flow left ventricular assist systems increase the rate of survival among patients with advanced heart failure but are associated with the development of pump thrombosis. We investigated the effects of a new magnetically levitated centrifugal continuous-flow pump that was engineered to avert thrombosis. We randomly assigned patients with advanced heart failure to receive either the new centrifugal continuous-flow pump or a commercially available axial continuous-flow pump. Patients could be enrolled irrespective of the intended goal of pump support (bridge to transplantation or destination therapy). The primary end point was a composite of survival free of disabling stroke (with disabling stroke indicated by a modified Rankin score >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove the device at 6 months after implantation. The trial was powered for noninferiority testing of the primary end point (noninferiority margin, -10 percentage points). Of 294 patients, 152 were assigned to the centrifugal-flow pump group and 142 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 131 patients (86.2%) in the centrifugal-flow pump group and in 109 (76.8%) in the axial-flow pump group (absolute difference, 9.4 percentage points; 95% lower confidence boundary, -2.1 [P<0.001 for noninferiority]; hazard ratio, 0.55; 95% confidence interval [CI], 0.32 to 0.95 [two-tailed P=0.04 for superiority]). There were no significant between-group differences in the rates of death or disabling stroke, but reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (1 [0.7%] vs. 11 [7.7%]; hazard ratio, 0.08; 95% CI, 0.01 to 0.60; P=0.002). Suspected or confirmed pump thrombosis occurred in no patients in the centrifugal-flow pump group and in 14 patients (10.1%) in the axial-flow pump group. Among patients with advanced heart failure, implantation of a fully magnetically levitated centrifugal-flow pump was associated with better outcomes at 6 months than was implantation of an axial-flow pump, primarily because of the lower rate of reoperation for pump malfunction. (Funded by St. Jude Medical; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).
Coronary blood flow during percutaneous hemopump in patients at high risk for angioplasty
NASA Astrophysics Data System (ADS)
Geschwind, Herbert J.; Dubois-Rande, Jean Luc; Dupouy, Patrick J.; Larrazet, Fabrice S.; Kvasnicka, Jan; El-Ghalid, Ahmed; Deleuze, Philippe; Loisance, Daniel
1995-05-01
Hemopump is a ventricular assist device which is aimed at improving the management of high- risk patients for PTCA. The aim of the study was to access coronary blood flow velocity during hemopump. The hemopump was inserted percutaneously into the femoral artery. Coronary blood flow was measured with a 12 MHz Doppler-tipped guidewire proximal and distal to the stenosis before, during and after PTCA. Coronary vascular reserve was assessed by intracoronary 12 mg bolus injection of Papaverine. Collateral flow was assessed during balloon occlusion by inverted velocity signals below baseline. Eight patients aged 59 +/- 11 yrs, with unstable angina, a last patent vessel and/or major left ventricular dysfunction (EF < 0.20) had hemopump during PTCA of stenosis (86 +/- 14%) of the LAD (n equals 4) or the LCX (n equals 4). Collateral flow was slightly increased (+25 +/- 18%) by the Hemopump. Hemopump did not strongly affect coronary flow velocity, did not significantly increase collateral flow and increased slightly coronary vascular reserve.
Pulsatile flow in ventricular catheters for hydrocephalus
NASA Astrophysics Data System (ADS)
Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.
2017-05-01
The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.
Left ventricular assist device therapy in patients with restrictive and hypertrophic cardiomyopathy.
Topilsky, Yan; Pereira, Naveen L; Shah, Dipesh K; Boilson, Barry; Schirger, John A; Kushwaha, Sudhir S; Joyce, Lyle D; Park, Soon J
2011-05-01
Left ventricular assist device (LVAD) is being increasingly used in patients with end-stage dilated and ischemic cardiomyopathy. There have been no clinical trials addressing the use of LVAD therapy in patients with end-stage heart failure caused by restrictive (RCM) or hypertrophic cardiomyopathy (HCM). The purpose of this study was therefore to analyze the outcome of LVAD therapy in these patients. Eighty-three patients received continuous axial flow LVAD (Heart mate II, Thoratec, Pleasanton, CA) from February 2007 to May 2010 at our institution. We analyzed the baseline characteristics and surgical and long-term impact of LVAD therapy in 8 patients with RCM or HCM and compared their outcomes with the 75 patients with dilated and ischemic cardiomyopathy. Compared with patients with ischemic or dilated cardiomyopathy, patients with RCM and HCM have significantly smaller left ventricular end-diastolic dimensions (52.5±6 mm versus 68.6±8 mm; P<0.0001) and increased thickness of septal (16 [12, 19] mm versus 10[8.5, 11] mm, P=0.0003) and higher left ventricular ejection fraction (21 [20, 36]% versus 17 [15, 22]%; P=0.0009). We found no difference in early mortality (12.5% versus 9.3%, P=0.57) or length of hospital stay (11 [8, 45] days versus 18.5 [12.2, 27.7] days; P=0.51) between the 2 groups. The right atrial pressure was higher (18 [15, 20] mm Hg versus 12 [9, 15] mm Hg, P=0.03), and pump flow was lower (4.3 [3.8, 4.5] L versus 5.2 [4.7, 5.5] L, P=0.001) after LVAD implantation in patients with RCM and HCM. Central venous catheter related infections were more common in patients with RCM and HCM (87.5% versus 44.5%, P=0.006). There was no difference in the total number of blood units transfused. Median (min, max) follow-up duration after LVAD implantation was 166 [1, 1044] days. The 1-year actuarial survival rate was not different between the 2 groups (87.5% [95% confidence interval, 52.9% to 97.8%] versus 73.2 [95% confidence interval, 60% to 85%]; P=0.77). Our preliminary data show that patients with end-stage heart failure caused by RCM or HCM may benefit from continuous axial flow LVAD therapy. This small study suggests that mortality is comparable with those patients who have dilated or ischemic cardiomyopathy, but right heart failure, prolonged inotropic use, and central venous catheter infections are more common in patients with RCM and HCM who were treated with LVAD. Because of the small numbers the differences should be interpreted cautiously, and prospective clinical trials would be required to recommend this therapy for these patients as bridge to transplantation or destination treatment.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-11-01
Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.
Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng
2012-01-01
OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204
Reeder, G S; Currie, P J; Fyfe, D A; Hagler, D J; Seward, J B; Tajik, A J
1984-11-01
Extracardiac valved conduits are often employed in the repair of certain complex congenital heart defects; late obstruction is a well recognized problem that usually requires catheterization for definitive diagnosis. A reliable noninvasive method for detecting conduit stenosis would be clinically useful in identifying the small proportion of patients who develop this problem. Continuous wave Doppler echocardiography has been used successfully to estimate cardiac valvular obstructive lesions noninvasively. Twenty-three patients with prior extracardiac conduit placement for complex congenital heart disease underwent echocardiographic and continuous wave Doppler echocardiographic examinations to determine the presence and severity of conduit stenosis. In 20 of the 23 patients, an adequate conduit flow velocity profile was obtained, and in 10 an abnormally increased conduit flow velocity was present. All but one patient had significant obstruction proven at surgery and in one patient, surgery was planned. In three patients, an adequate conduit flow velocity profile could not be obtained but obstruction was still suspected based on high velocity tricuspid regurgitant Doppler signals. In these three patients, subsequent surgery also proved that conduit stenosis was present. Doppler-predicted gradients and right ventricular pressures showed an overall good correlation (r = 0.90) with measurements at subsequent cardiac catheterization. Continuous wave Doppler echocardiography appears to be a useful noninvasive tool for the detection and semiquantitation of extracardiac conduit stenosis.
Right Heart Vorticity and Right Ventricular Diastolic Dysfunction
NASA Astrophysics Data System (ADS)
Browning, James; Hertzberg, Jean; Fenster, Brett; Schroeder, Joyce
2015-11-01
Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for the 3-dimensional characterization of blood flow in the right ventricle (RV) and right atrium (RA). In this study, we investigate and quantify differences in the characteristics of coherent rotating flow structures (vortices) in the RA and RV between subjects with right ventricular diastolic dysfunction (RVDD) and normal controls. Fifteen RVDD subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine RVDD stage as well as pulmonary artery systolic pressure (PASP). CMR data was used for RA and RV vortex quantification and visualization during early ventricular diastole and the results are compared between healthy subjects and those with RVDD. The resulting trends are discussed and hypotheses are presented regarding differences in vortex characteristics between healthy and RVDD subjects cohorts.
Computational Flow Analysis of a Left Ventricular Assist Device
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Kwak, Dochan; Benkowski, Robert
1995-01-01
Computational fluid dynamics has been developed to a level where it has become an Indispensable part of aerospace research and design. Technology developed foe aerospace applications am also be utilized for the benefit of human health. For example, a flange-to-flange rocket engine fuel-pump simulation includes the rotating and non-rotating components: the flow straighteners, the impeller, and diffusers A Ventricular Assist Device developed by NASA Johnson Space Center and Baylor College of Medicine has a design similar to a rocket engine fuel pump in that it also consists of a flow straightener, an impeller, and a diffuser. Accurate and detailed knowledge of the flowfield obtained by incompressible flow calculations can be greatly beneficial to designers in their effort to reduce the cost and improve the reliability of these devices. In addition to the geometric complexities, a variety of flow phenomena are encountered in biofluids Then include turbulent boundary layer separation, wakes, transition, tip vortex resolution, three-dimensional effects, and Reynolds number effects. In order to increase the role of Computational Fluid Dynamics (CFD) in the design process the CFD analysis tools must be evaluated and validated so that designers gain Confidence in their use. The incompressible flow solver, INS3D, has been applied to flow inside of a liquid rocket engine turbopump components and extensively validated. This paper details how the computational flow simulation capability developed for liquid rocket engine pump component analysis has bean applied to the Left Ventricular Assist Device being developed jointly by NASA JSC and Baylor College of Medicine.
An implantable centrifugal blood pump for long term circulatory support.
Yamazaki, K; Litwak, P; Kormos, R L; Mori, T; Tagusari, O; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Umezu, M; Tomioka, J; Koyanagi, H; Griffith, B P
1997-01-01
A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.
Marks, J D; Pantalos, G M; Long, J W; Kinoshita, M; Everett, S D; Olsen, D B
1999-01-01
Unlike the mechanisms of intraaortic balloon pump (IABP) support, the mechanisms by which transvalvular axial flow Hemopump (HP) support benefit dysfunctional myocardium are less clearly understood. To help elucidate these mechanisms, hemodynamic, metabolic, and mechanical indexes of left ventricular function were measured during conditions of control, ischemic dysfunction, IABP support, and HP support. A large animal (calf) model of left ventricular dysfunction was created with multiple coronary ligations. Peak intraventricular pressure increased with HP support and decreased with IABP support. Intramyocardial pressure (an indicator of intramyocardial stress), time rate of pressure change (an indicator of contractility), and left ventricular myocardial oxygen consumption decreased with IABP and HP support. Left ventricular work decreased with HP support and increased with IABP support. During HP support, indexes of wall stress, work, and contractility, all primary determinants of oxygen consumption, were reduced. During IABP support, indexes of wall stress and contractility were reduced and external work increased. These changes were attributed primarily to changes in ventricular preload, and geometry for HP support, and to a reduction in afterload for IABP support. These findings support the hypothesis that both HP and IABP support reduce intramyocardial stress development and the corresponding oxygen consumption, although via different mechanisms.
Rennyson, Stephen L; Shah, Keyur B; Tang, Daniel G; Kasirajan, Vigneshwar; Pedram, Sammy; Cahoon, William; Malhotra, Rajiv
2013-01-01
Left ventricular support devices (LVADs) are associated with a propensity toward gastrointestinal bleeding. A postulated mechanism is related to gastrointestinal arteriovenous malformations secondary to nonpulsatile flow. We describe a case of LVAD-related, gastrointestinal bleeding successfully treated with a combination of subcutaneous and intramuscular depot formulations of octreotide.
Histotripsy for Pediatric Cardiac Applications: In Vivo Neonatal Pig Model
NASA Astrophysics Data System (ADS)
Miller, Ryan M.; Owens, Gabe; Ensing, Gregory; Ludomirsky, Achiau; Cain, Charles; Xu, Zhen
2010-03-01
This study investigated the in vivo feasibility of using histotripsy to non-invasively create a flow channel between the ventricles by generating a perforation of the ventricular septum, clinically referred to as a ventricular septum defect (VSD). The overall goal is to develop a non-invasive procedure to aid in the treatment of neonatal patients with complex congenital heart diseases such as Hypoplastic Left Heart Syndrome (HLHS). Histotripsy is a therapeutic ultrasound technique that produces mechanical fractionation of soft tissue through controlled cavitation. The study was conducted in a live and intact neonatal pig model. The ventricular septum in the neonatal pig heart was treated with histotripsy delivered by a spherically focused 1 MHz transducer positioned outside the chest wall. Histotripsy treatment was applied using 5-cycle ultrasound pulses at 1 kHz pulse repetition frequency with 12-18 MPa peak negative pressure. The treatment was guided and monitored with ultrasound imaging. In all nine subjects treated, a bubble cloud was generated on the ventricular septum using histotripsy, and visualized with ultrasound imaging. Within 20 seconds to 4 minutes following the initiation of a bubble cloud, a VSD was created in all nine pigs and confirmed by the detection of blood flow through the ventricular septum with color Doppler ultrasound. Gross morphology and histology on all hearts showed a demarcated perforation in the ventricular septum. This study shows that a VSD can be created in an intact neonatal animal using extracorporeal histotripsy under real-time ultrasound guidance.
Anatomy of the ventricular septal defect in outflow tract defects: similarities and differences.
Mostefa-Kara, Meriem; Bonnet, Damien; Belli, Emre; Fadel, Elie; Houyel, Lucile
2015-03-01
The study objective was to analyze the anatomy of the ventricular septal defect found in various phenotypes of outflow tract defects. We reviewed 277 heart specimens with isolated outlet ventricular septal defect without subpulmonary stenosis (isolated outlet ventricular septal defect, 19); tetralogy of Fallot (71); tetralogy of Fallot with pulmonary atresia (51); common arterial trunk (54); double outlet right ventricle (65) with subaortic, doubly committed, or subpulmonary ventricular septal defect; and interrupted aortic arch type B (17). Special attention was paid to the rims of the ventricular septal defect viewed from the right ventricular side and the relationships between the tricuspid and aortic valves. The ventricular septal defect was always located in the outlet of the right ventricle, between the 2 limbs of the septal band. There was a fibrous continuity between the tricuspid and aortic valves in 74% of specimens with isolated outlet ventricular septal defect, 66% of specimens with tetralogy of Fallot, 39% of specimens with tetralogy of Fallot with pulmonary atresia, 4.6% of specimens with double outlet right ventricle, 1.8% of specimens with common arterial trunk, and zero of specimens with interrupted aortic arch type B (P < .005). When present, this continuity always involved the anterior tricuspid leaflet. The ventricular septal defect in outflow tract defects is always an outlet ventricular septal defect, cradled between the 2 limbs of the septal band. However, there are some differences regarding the posteroinferior and superior rims of the ventricular septal defect. These differences suggest an anatomic continuum from the isolated outlet ventricular septal defect to the interrupted aortic arch type B rather than distinct physiologic phenotypes, related to various degrees of abnormal rotation of the outflow tract during heart development: minimal in isolated outlet ventricular septal defect; incomplete in tetralogy of Fallot, tetralogy of Fallot with pulmonary atresia, and double outlet right ventricle; absent in common arterial trunk; and excessive in interrupted aortic arch type B. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Li, Bin; Yang, Hui; Wang, Xiaochen; Zhan, Yongkun; Sheng, Wei; Cai, Huanhuan; Xin, Haoyang; Liang, Qianqian; Zhou, Ping; Lu, Chao; Qian, Ruizhe; Chen, Sifeng; Yang, Pengyuan; Zhang, Jianyi; Shou, Weinian; Huang, Guoying; Liang, Ping; Sun, Ning
2017-09-29
Most infarctions occur in the left anterior descending coronary artery and cause myocardium damage of the left ventricle. Although current pluripotent stem cells (PSCs) and directed cardiac differentiation techniques are able to generate fetal-like human cardiomyocytes, isolation of pure ventricular cardiomyocytes has been challenging. For repairing ventricular damage, we aimed to establish a highly efficient purification system to obtain homogeneous ventricular cardiomyocytes and prepare engineered human ventricular heart muscles in a dish. The purification system used TALEN-mediated genomic editing techniques to insert the neomycin or EGFP selection marker directly after the myosin light chain 2 (MYL2) locus in human pluripotent stem cells. Purified early ventricular cardiomyocytes were estimated by immunofluorescence, fluorescence-activated cell sorting, quantitative PCR, microelectrode array, and patch clamp. In subsequent experiments, the mixture of mature MYL2-positive ventricular cardiomyocytes and mesenchymal cells were cocultured with decellularized natural heart matrix. Histological and electrophysiology analyses of the formed tissues were performed 2 weeks later. Human ventricular cardiomyocytes were efficiently isolated based on the purification system using G418 or flow cytometry selection. When combined with the decellularized natural heart matrix as the scaffold, functional human ventricular heart muscles were prepared in a dish. These engineered human ventricular muscles can be great tools for regenerative therapy of human ventricular damage as well as drug screening and ventricular-specific disease modeling in the future.
Berg, Robert A; Sorrell, Vincent L; Kern, Karl B; Hilwig, Ronald W; Altbach, Maria I; Hayes, Melinda M; Bates, Kathryn A; Ewy, Gordon A
2005-03-08
Most out-of-hospital ventricular fibrillation (VF) is prolonged (>5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29% but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34%. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF (<5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF (5 to 15 minutes) does not.
Hollow mandrin facilitates external ventricular drainage placement.
Heese, O; Regelsberger, J; Kehler, U; Westphal, M
2005-07-01
Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.
Forman, Mervyn B; Jackson, Edwin K
2007-11-01
High risk ST segment elevation myocardial infarction (STEMI) patients undergoing reperfusion therapy continue to exhibit significant morbidity and mortality due in part to myocardial reperfusion injury. Importantly, preclinical studies demonstrate that progressive microcirculatory failure (the "no-reflow" phenomenon) contributes significantly to myocardial reperfusion injury. Diagnostic techniques to measure tissue perfusion have validated this concept in humans, and it is now clear that abnormal tissue perfusion occurs frequently in STEMI patients undergoing reperfusion therapy. Moreover, because tissue perfusion correlates poorly with epicardial blood flow (TIMI flow grade), clinical studies show that tissue perfusion is an independent predictor of early and late mortality in STEMI patients and is associated with infarct size, ventricular function, CHF and ventricular arrhythmias. The mechanisms responsible for abnormal tissue perfusion are multifactorial and include both mechanical obstruction and vasoconstrictor humoral factors. Adenosine, an endogenous nucleoside, maintains microcirculatory flow following reperfusion by activating four well-characterized extracellular receptors. Because activation of adenosine receptors attenuates the mechanical and functional mechanisms leading to the "no reflow" phenomenon and activates other cardioprotective pathways as well, it is not surprising that both experimental and clinical studies show striking myocardial salvage with intravenous infusions of adenosine administered in the peri-reperfusion period. For example, a post hoc analysis of the AMISTAD II trial indicates a significant reduction in 1 and 6-month mortality in STEMI patients undergoing reperfusion therapy who are treated with adenosine within 3 hours of symptoms. In conclusion, adenosine's numerous cardioprotective effects, including attenuation of the "no-reflow" phenomenon, support its use in high risk STEMI undergoing reperfusion.
Fresiello, Libera; Gu, Y John; Ferrari, Gianfranco; Di Molfetta, Arianna; Rakhorst, Gerhard
2011-05-01
The pulsatile catheter pump (PUCA pump) is a left ventricular assist device that provides additional flow to the left ventricle. It is usually run in order to ensure a counterpulsation effect, as in the case of the intra-aortic balloon pump (IABP). Because of this similarity, a comparison between the PUCA pump and the IABP was conducted from both the hemodynamic and energetic points of view. Numerical models of the two devices were created and connected to the CARDIOSIM cardiovascular simulator. The PUCA and IABP models were then verified using in vivo experimental data and literature data, respectively. Numerical experiments were conducted for different values of left ventricular end systolic elastance (Els) and systemic arterial compliance (Csa). The energetic comparison was conducted taking into account the diastolic pressure time index and the endocardial viability ratio. Hemodynamic results expressed as cardiac output (CO) and mean coronary blood flow (CBF) show that both the IABP and the PUCA pump efficacy decrease with higher values of Els and Csa. The IABP especially shows higher sensitivity to these parameters, to the extent that in some cases CO actually drops and CBF does not increase. On the other hand, for lower values of Csa, IABP performance improves so much that the PUCA pump flow needs to be increased in order to ensure a hemodynamic effect comparable to that of the IABP. Energetic results show a trend similar to the hemodynamic ones. The study will be continued by investigating other energetic variables and the autonomic response of the cardiovascular system.
NASA Astrophysics Data System (ADS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 ° head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 ° upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alterating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.
1998-01-01
Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.
Malakan Rad, Elaheh; Awad, Sawsan; Hijazi, Ziyad M
2014-01-01
Congenital left ventricular outpouchings (LVOs) are reported under five overlapping and poorly defined terms including left ventricular accessory chamber, left ventricular aneurysm (LVA), left ventricular diverticulum (LVD), double-chambered LV, and accessory left ventricle. Diagnostic criteria are frequently mixed and not mutually exclusive. They convey no information regarding treatment strategy and prognosis. The aim of this systematic review is to provide a clear and inclusive classification, with therapeutic and prognostic implications, for congenital LVOs. We performed three separate sets of search on three subjects including "congenital left ventricular outpouchings," "important and simply measurable markers of left ventricular function," and "relationship of mechanics of intraventricular blood flow and optimal vortex formation in left ventricle and elliptical geometry of LV." We enrolled case series, review articles, and case reports with literature review. All types of acquired LVO's were excluded. We studied the abstracts of all searched articles. We focused on diagnostic criteria and patients' outcome. To examine the validity and reliability of the novel classification, fifteen previous studies were revisited using the novel classification. A total of 20 papers from 11 countries fulfilled our inclusion criteria. The age of patients ranged from prenatal age to geriatric age range. Diagnostic criteria were clearly stated only for two of the above five terms (i.e., congenital LVA and congenital LVD). Cases with mixed diagnostic criteria were frequent.Elliptical geometry of left ventricle was found to have significant impact on effective blood flow mechanics in LV. A simple inclusive classification for congenital LVOs, with therapeutic and prognostic implications, was introduced. The cornerstone of this classification is elliptical LV geometry. Large-type IIc LVO have dismal prognosis, if left untreated. LVO type I and small LVO type IIa have the best prognosis. © 2014 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurford, W.; Lowenstein, E.; Zapol, W.
1985-05-01
To determine whether branched chain fatty acid extraction is reduced during right ventricular (RV) dysfunction due to acute pulmonary artery hypertension, studies were done in 6 anesthetized dogs. Regional branched chain fatty acid extraction was measured by comparing the myocardial uptake of I-125 labeled 15-(p-(iodophenyl))-3-methylpentadecanoic acid (I-PDA) to myocardial blood flow. Acute pulmonary hypertension was induced by incremental intravenous injection of 100 micron diameter glass beads into six pentobarbital anesthetized, mechanically ventilated dogs. Myocardial blood flow was measured by radiolabeled microspheres both under baseline conditions and during pulmonary hypertension. Mean RV pressure rose from 12 +- 2 (mean +- SEM)more » to 30 +-3mmHg resulting in a 225 +- 16% increase in RV stroke work. RV ejection fraction, as assessed by gated blood pool scans fell from 39 +- 2 to 18 +- 2%. Left ventricular (LV) pressures, stroke work and ejection fraction were unchanged. Myocardial blood flow increased 132 + 59% in the RV free wall and 67 +- 22% in the RV septum. LV blood flow was unchanged. Despite increased RV work and myocardial blood flow, no differences were noted in the branched chain fatty acid extraction ratios among LV or RV free walls or septum. The authors conclude that early RV dysfunction associated with pulmonary artery hypertension is not due to inadequate myocardial blood flow or branched chain fatty acid extraction.« less
Saeki, A; Recchia, F A; Senzaki, H; Kass, D A
1996-01-01
1. The role of nitric oxide (NO) in the regulation of basal coronary perfusion and ventricular chamber energetics was studied in isovolumetrically contracting isolated blood-perfused canine hearts. Hearts were cross-perfused by a donor animal prior to isolation, and chamber volume controlled by a servo-pump. Coronary sinus flow and arterial-coronary sinus oxygen difference were measured to determine energetic efficiency. 2. NO synthase (NOS) was competitively inhibited by NG-monomethyl-L-arginine (L-NMMA; 0.5 mg kg-1, intracoronary), resulting in a reduction of acetylcholine (50 micrograms min-1)-induced flow augmentation from 143 to 62% (P < 0.001). 3. NOS inhibition had no significant effect on basal coronary flow. Coronary pressure-flow relationships were determined at a constant cardiac workload by varying mean perfusion pressure between 20 and 150 mmHg. Neither the shape of the relationship, nor the low-pressure value at which flow regulation was substantially diminished were altered by NOS inhibition. 4. Myocardial efficiency was assessed by the relationship between myocardial oxygen consumption and total pressure-volume area (PVA), with cavity volume altered to generate varying PVAs. This relative load-independent measure of energetic efficiency was minimally altered by NOS inhibition. 5. These results contrast with isolated crystalloid-perfused heart experiments and suggest that in hearts with highly controlled ventricular loading and whole-blood perfusion, effects of basal NO production on coronary perfusion and left ventricular energetics are minimal. PMID:8866868
Bartoli, Carlo R.; Dowling, Robert D.
2011-01-01
Synopsis The recent, widespread success of mechanical circulatory support has ushered in a new era of cardiovascular medicine in which numerous implantable devices exist to treat advanced heart failure. As cardiac assist devices gain prevalence in the clinical management of cardiovascular disease, it is increasingly important to raise awareness of novel device systems, the unique mechanisms by which they function, and implications for patient management. In this article, we present state-of-the-art devices that are currently under development or in clinical trials. Devices are categorized as Standard Full-Support (HeartMate III, CorAide, Evaheart LVAS), Less-Invasive Full-Support (MVAD), Partial-Support (CircuLite Synergy Pocket Micro-Pump, Reitan Catheter Pump, Procyrion CAD, C-Pulse, Symphony Counterpulsation Device) Right Ventricular Assist Device (RVAD; DexAide, Impella RD Recover, Impella RP), and Total Artificial Heart (TAH; CardioWest, AbioCor II, Continuous-Flow TAH, Continuous-Flow BiVAD). Implantation strategy, mechanism of action, durability, efficacy, hemocompatibility, and human factors such as quality of life during device support are considered. The feasibility of novel strategies for unloading the failing heart is examined. PMID:22062206
NASA Technical Reports Server (NTRS)
Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.;
2001-01-01
Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-10-01
To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure-flow relationship. Prospective study. Tertiary care hospital. 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure-flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non-Q-wave MI (22.5 (9.1) mm Hg), to Q-wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non-infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end-diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. After an MI, the coronary pressure-flow relationship is shifted to the right both in the infarcted and in the non-infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction.
Lei, M H; Chen, J J; Ko, Y L; Cheng, J J; Kuan, P; Lien, W P
1995-01-01
This study assessed the usefulness of continuous wave Doppler echocardiography and color flow mapping in evaluating pulmonary regurgitation (PR) and estimating pulmonary artery (PA) pressure. Forty-three patients were examined, and high quality Doppler spectral recordings of PR were obtained in 32. All patients underwent cardiac catheterization, and simultaneous PA and right ventricular (RV) pressures were recorded in 17. Four Doppler regurgitant flow velocity patterns were observed: pandiastolic plateau, biphasic, peak and plateau, and early diastolic triangular types. The peak diastolic and end-diastolic PA-to-RV pressure gradients derived from the Doppler flow profiles correlated well with the catheter measurements (r = 0.95 and r = 0.95, respectively). As PA pressure increased, the PR flow velocity became higher; a linear relationship between either systolic or mean PA pressure and Doppler-derived peak diastolic pressure gradient was noted (r = 0.90 and 0.94, respectively). Based on peak diastolic gradients of < 15, 15-30 or > 30 mm Hg, patients could be separated as those with mild, moderate or severe pulmonary hypertension, respectively (p < 0.05). A correlation was also observed between PA diastolic pressure and Doppler-derived end-diastolic pressure gradient (r = 0.91). Moreover, the Doppler velocity decay slope of PR closely correlated with that derived from the catheter method (r = 0.98). The decay slope tended to be steeper with the increment in regurgitant jet area and length obtained from color flow mapping. In conclusion, continuous wave Doppler evaluation of PR is a useful means for noninvasive estimation of PA pressure, and the Doppler velocity decay slope seems to reflect the severity of PR.
Modeling and control of a brushless DC axial flow ventricular assist device.
Giridharan, Guruprasad A; Skliar, Mikhail; Olsen, Donald B; Pantalos, George M
2002-01-01
This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.
Capoccia, Massimo
2016-12-12
The impact of left ventricular assist devices (LVADs) for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs), based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs). The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial) and the HeartWare HVAD (centrifugal) rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal) is now emerging as the new promising device with encouraging preliminary results. There are now enough pumps on the market: it is time to focus on the complications in order to achieve the full potential and selling-point of this type of technology for the treatment of the increasing heart failure patient population.
Aggarwal, Sourabh; Xie, Feng; High, Robin; Pavlides, Gregory; Porter, Thomas R
2018-06-01
Although microvascular flow abnormalities have been observed following epicardial recanalization in acute ST-segment elevation myocardial infarction (STEMI), the prevalence and severity of these abnormalities in the current era of rapid percutaneous coronary intervention (PCI) has not been evaluated. The objective of this study was to assess microvascular perfusion (MVP) following successful primary PCI in patients with STEMI and how it affects clinical outcome. In this single-center, retrospective study, 170 patients who successfully underwent emergent PCI for STEMI were assessed using real-time myocardial contrast echocardiography using a continuous infusion of intravenous commercial microbubbles (3% Definity). Three patterns of myocardial contrast replenishment were observed following intermittent high-mechanical index impulses: infarct zone replenishment within 4 sec (normal MVP), delays in contrast replenishment but normal plateau intensity (delayed MVP [dMVP]), and both delays in replenishment and reduced plateau intensity (microvascular obstruction [MVO]). Changes in left ventricular ejection fraction at 6 months and clinical event rate at 12 months (death, recurrent infarction, need for defibrillator placement, or heart failure admission) were compared. Normal MVP was seen in 62 patients (36%), dMVP in 49 (29%), and MVO in 59 (35%). Left anterior descending coronary artery infarct location was the only parameter independently associated with dMVP or MVO, independent of age, cardiac risk factors, door-to-dilation time, pre-PCI Thrombolysis In Myocardial Infarction flow grade, and thrombus burden. A dMVP pattern had a similar reduction in left ventricular ejection fraction as MVO at hospital discharge but had recovery of left ventricular ejection fraction at 6 months and a greater than fourfold lower event rate than the MVO group (P < .001). MVO and dMVP are frequently seen following contemporary successful PCI for STEMI, especially following left anterior descending coronary artery infarction. Despite a similar area at risk, a dMVP pattern has better functional recovery and clinical outcome than MVO. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Hombach, V; Kebbel, U; Höpp, H W; Winter, U J; Braun, V; Deutsch, H; Hirche, H; Hilger, H H
1982-12-24
A new ECG-amplifier system for recording cardiac microvolt potentials from the body surface is described. The improvement in signal-to-noise ratio was achieved by using specially designed suction electrodes, which were isolated from each other; by applying parallel signal averaging from four electrode pairs via four low-noise amplifiers; and by conducting the registration in Faraday cage. in 14 normal subjects, 12 patients with coronary heart disease and one patient with surgically corrected ventricular septal defect and pulmonary stenosis, pre-P-potentials (possible sinus node activity), His bundle potentials and ventricular late potentials were recorded with differing degrees of success. Variations of the time intervals to the preceding QRS complex were observed within the S-T segment in six of nine patients with demonstrable ventricular late ventricular late potentials. The advantage of such continuously recording ECG system lies in the highly accurate registration of cardiac micropotentials, particularly with ventricular late potentials that are changing in time, whereas the signal-averaging technique does not provide such possibilities.
Campbell, K B; Shroff, S G; Kirkpatrick, R D
1991-06-01
Based on the premise that short-time-scale, small-amplitude pressure/volume/outflow behavior of the left ventricular chamber was dominated by dynamic processes originating in cardiac myofilaments, a prototype model was built to predict pressure responses to volume perturbations. In the model, chamber pressure was taken to be the product of the number of generators in a pressure-bearing state and their average volumetric distortion, as in the muscle theory of A.F. Huxley, in which force was equal to the number of attached crossbridges and their average lineal distortion. Further, as in the muscle theory, pressure generators were assumed to cycle between two states, the pressure-bearing state and the non-pressure-bearing state. Experiments were performed in the isolated ferret heart, where variable volume decrements (0.01-0.12 ml) were removed at two commanded flow rates (flow clamps, -7 and -14 ml/sec). Pressure responses to volume removals were analyzed. Although the prototype model accounted for most features of the pressure responses, subtle but systematic discrepancies were observed. The presence or absence of flow and the magnitude of flow affected estimates of model parameters. However, estimates of parameters did not differ when the model was fitted to flow clamps with similar magnitudes of flows but different volume changes. Thus, prototype model inadequacies were attributed to misrepresentations of flow-related effects but not of volume-related effects. Based on these discrepancies, an improved model was built that added to the simple two-state cycling scheme, a pathway to a third state. This path was followed only in response to volume change. The improved model eliminated the deficiencies of the prototype model and was adequate in accounting for all observations. Since the template for the improved model was taken from the cycling crossbridge theory of muscle contraction, it was concluded that, in spite of the complexities of geometry, architecture, and regional heterogeneity of function and structure, crossbridge mechanisms dominated the short-time-scale dynamics of left ventricular chamber behavior.
Angadi, Siddhartha S; Mookadam, Farouk; Lee, Chong D; Tucker, Wesley J; Haykowsky, Mark J; Gaesser, Glenn A
2015-09-15
Heart failure with preserved ejection fraction (HFpEF) is a major cause of morbidity and mortality. Exercise training is an established adjuvant therapy in heart failure; however, the effects of high-intensity interval training (HIIT) in HFpEF are unknown. We compared the effects of HIIT vs. moderate-intensity aerobic continuous training (MI-ACT) on peak oxygen uptake (V̇o₂peak), left ventricular diastolic dysfunction, and endothelial function in patients with HFpEF. Nineteen patients with HFpEF (age 70 ± 8.3 yr) were randomized to either HIIT (4 × 4 min at 85-90% peak heart rate, with 3 min active recovery) or MI-ACT (30 min at 70% peak heart rate). Fifteen patients completed exercise training (HIIT: n = 9; MI-ACT: n = 6). Patients trained 3 days/wk for 4 wk. Before and after training patients underwent a treadmill test for V̇o₂peak determination, 2D-echocardiography for assessment of left ventricular diastolic dysfunction, and brachial artery flow-mediated dilation (FMD) for assessment of endothelial function. HIIT improved V̇o₂peak (pre = 19.2 ± 5.2 ml·kg(-1)·min(-1); post = 21.0 ± 5.2 ml·kg(-1)·min(-1); P = 0.04) and left ventricular diastolic dysfunction grade (pre = 2.1 ± 0.3; post = 1.3 ± 0.7; P = 0.02), but FMD was unchanged (pre = 6.9 ± 3.7%; post = 7.0 ± 4.2%). No changes were observed following MI-ACT. A trend for reduced left atrial volume index was observed following HIIT compared with MI-ACT (-3.3 ± 6.6 vs. +5.8 ± 10.7 ml/m(2); P = 0.06). In HFpEF patients 4 wk of HIIT significantly improved V̇o₂peak and left ventricular diastolic dysfunction. HIIT may provide a more robust stimulus than MI-ACT for early exercise training adaptations in HFpEF. Copyright © 2015 the American Physiological Society.
Moller, Thomas; Lindberg, Harald; Lund, May Brit; Holmstrom, Henrik; Dohlen, Gaute; Thaulow, Erik
2018-06-01
We previously demonstrated an abnormally high right ventricular systolic pressure response to exercise in 50% of adolescents operated on for isolated ventricular septal defect. The present study investigated the prevalence of abnormal right ventricular systolic pressure response in 20 adult (age 30-45 years) patients who underwent surgery for early ventricular septal defect closure and its association with impaired ventricular function, pulmonary function, or exercise capacity. The patients underwent cardiopulmonary tests, including exercise stress echocardiography. Five of 19 patients (26%) presented an abnormal right ventricular systolic pressure response to exercise ⩾ 52 mmHg. Right ventricular systolic function was mixed, with normal tricuspid annular plane systolic excursion and fractional area change, but abnormal tricuspid annular systolic motion velocity (median 6.7 cm/second) and isovolumetric acceleration (median 0.8 m/second2). Left ventricular systolic and diastolic function was normal at rest as measured by the peak systolic velocity of the lateral wall and isovolumic acceleration, early diastolic velocity, and ratio of early diastolic flow to tissue velocity, except for ejection fraction (median 53%). The myocardial performance index was abnormal for both the left and right ventricle. Peak oxygen uptake was normal (mean z score -0.4, 95% CI -2.8-0.3). There was no association between an abnormal right ventricular systolic pressure response during exercise and right or left ventricular function, pulmonary function, or exercise capacity. Abnormal right ventricular pressure response is not more frequent in adult patients compared with adolescents. This does not support the theory of progressive pulmonary vascular disease following closure of left-to-right shunts.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Fukamachi, Kiyotaka; Popović, Zoran B; Inoue, Masahiro; Doi, Kazuyoshi; Schenk, Soren; Ootaki, Yoshio; Kopcak, Michael W; McCarthy, Patrick M
2004-03-01
The objective of this study was to evaluate the changes in mitral annular and left ventricular dimensions and left ventricular pressure-volume relations produced by the Myocor Coapsys device that has been developed to treat functional mitral regurgitation (MR) off-pump. The Coapsys device, which consists of anterior and posterior epicardial pads connected by a sub-valvular chord, was implanted in seven dogs with functional MR resulting from pacing induced cardiomyopathy. The Coapsys device was then sized by drawing the posterior leaflet and annulus toward the anterior leaflet. During sizing, MR grade was assessed using color flow Doppler echocardiography. Final device size was selected when MR was eliminated or minimized. Following implantation, heart failure was maintained by continued pacing for a period of 8 weeks. Mitral annular and left ventricular dimensions and left ventricular pressure-volume relations were evaluated by two-dimensional echocardiography and a conductance catheter, respectively, at pre-sizing, post-sizing, and after 8 weeks. All implants were performed on beating hearts without cardiopulmonary bypass. Mean MR grade was reduced from 2.9+/-0.7 at pre-sizing to 0.7+/-0.8 at post-sizing (P<0.001), and was maintained at 0.8+/-0.8 after 8 weeks (P<0.01). The septal-lateral dimensions were significantly reduced at both mitral annular level [2.4+/-0.2 cm at pre-sizing, 1.5+/-0.3 cm at post-sizing (P<0.001) and 1.8+/-0.3 cm after 8 weeks (P<0.05)] and mid-papillary level [4.1+/-0.4 cm at pre-sizing, 2.4+/-0.2 cm at post-sizing (P<0.001) and 3.3+/-0.4 cm after 8 weeks (P<0.001)]. The end-systolic pressure-volume relation shifted leftward at post-sizing with a significantly steeper slope (P=0.03). There was a significant (P=0.03) leftward shift of the end-diastolic pressure-volume relation at post-sizing. After 8 weeks, these changes in pressure-volume relations tended to return to pre-sizing relations. The Coapsys device significantly reduced MR by treating both the mitral annular dilatation and the papillary muscle displacement. Despite these significant dimensional changes, the Coapsys device did not negatively affect the left ventricular pressure-volume relations.
Liu, Guang-Mao; Jin, Dong-Hai; Jiang, Xi-Hang; Zhou, Jian-Ye; Zhang, Yan; Chen, Hai-Bo; Hu, Sheng-Shou; Gui, Xing-Min
The ventricular assist pumps do not always function at the design point; instead, these pumps may operate at unfavorable off-design points. For example, the axial ventricular assist pump FW-2, in which the design point is 5 L/min flow rate against 100 mm Hg pressure increase at 8,000 rpm, sometimes works at off-design flow rates of 1 to 4 L/min. The hemolytic performance of the FW-2 at both the design point and at off-design points was estimated numerically and tested in vitro. Flow characteristics in the pump were numerically simulated and analyzed with special attention paid to the scalar sheer stress and exposure time. An in vitro hemolysis test was conducted to verify the numerical results. The simulation results showed that the scalar shear stress in the rotor region at the 1 L/min off-design point was 70% greater than at the 5 L/min design point. The hemolysis index at the 1 L/min off-design point was 3.6 times greater than at the 5 L/min design point. The in vitro results showed that the normalized index of hemolysis increased from 0.017 g/100 L at the 5 L/min design point to 0.162 g/100 L at the 1 L/min off-design point. The hemolysis comparison between the different blood pump flow rates will be helpful for future pump design point selection and will guide the usage of ventricular assist pumps. The hemolytic performance of the blood pump at the working point in the clinic should receive more focus.
Kuznetsova, Tatiana; Cauwenberghs, Nicholas; Knez, Judita; Thijs, Lutgarde; Liu, Yan-Ping; Gu, Yu-Mei; Staessen, Jan A
2015-04-01
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited information is available regarding the relationship between RRI and cardiac hemodynamics. We investigated these associations in randomly recruited subjects from a general population. In 171 participants (48.5% women; mean age, 52.2 years), using pulsed wave Doppler, we measured RRI (mean, 0.60) and left ventricular outflow tract (LVOT) and transmitral (E and A) blood flow peak velocities and its velocity time integrals (VTI). Using carotid applanation tonometry, we measured central pulse pressure and arterial stiffness indexes such as augmentation pressure and carotid-femoral pulse wave velocity. In stepwise regression analysis, RRI independently and significantly increased with female sex, age, body weight, brachial pulse pressure, and use of β-blockers, whereas it decreased with body height and mean arterial pressure. In multivariable-adjusted models with central pulse pressure and arterial stiffness indexes as the explanatory variables, we observed a significant and positive correlation of RRI only with central pulse pressure (P < 0.0001). Among the Doppler indexes of left ventricular blood flow, RRI was significantly and positively associated with LVOT and E peak velocities (P ≤ 0.012) and VTIs (P ≤ 0.010). We demonstrated that in unselected subjects RRI was significantly associated with central pulse pressure and left ventricular systolic and diastolic Doppler blood flow indexes. Our findings imply that in addition to the anthropometric characteristics, cardiac hemodynamic factors influence the intrarenal arterial Doppler waveform patterns. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
PCI in Patients Supported With CF-LVADs: Indications, Safety, and Outcomes.
Anyanwu, Emeka C; Ota, Takeyoshi; Sayer, Gabriel; Nathan, Sandeep; Jeevanandam, Valluvan; Shah, Atman; Uriel, Nir
2016-06-01
Patients with heart failure supported with left ventricular assist devices (LVADs) may require coronary intervention during their support. This case series seeks to explore the indications, safety, and outcomes of percutaneous coronary intervention (PCI) in this population. Electronic medical records of patients with LVADs undergoing PCI at a large academic medical center were reviewed. Demographics, reason for PCI, procedural success, complications, and outcomes were collected. From 2010-2014, a total of 6 patients underwent PCI post LVAD implantation. Three patients had PCI in the early postimplantation period (1-3 days post LVAD implantation) while the other three received it later in the LVAD support period. Three indications for PCI were found in the reviewed cases: right ventricular failure (right coronary artery stenting), bridge to left ventricular recovery, and ventricular tachycardia (VT) storm. All patients were maintained on triple blood thinning therapy (aspirin, clopidogrel, and warfarin). There were no acute complications during the interventions; however, 2 patients died in the early intervention period and 2 died much later. The 2 deaths in the early intervention period were related to fatal gastrointestinal bleeding while on dual-antiplatelet therapy and warfarin, and intractable VT that PCI did not correct. The 2 deaths in the late postintervention period occurred due to unknown causes nearly 1 and 2 years post intervention, respectively. PCI was performed in patients with continuous-flow LVAD with several possible indications and without acute complications. The utility of PCI in this patient population, however, is likely limited by the risk of bleeding related to combined antiplatelet and anticoagulation therapies as well as lack of immediate apparent benefit. Further studies are necessary to better characterize this risk as well as quantify any potential long-term benefits.
Kaku, T; Sakurai, S; Furuno, Y; Yashiro, A; Nakashima, Y; Kuroiwa, A
1995-08-01
We evaluated the effects of systolic anterior motion systolic anterior motion of the mitral valve on cardiac haemodynamics. Seven adult mongrel dogs in which systolic anterior motion-septal contact was observed after dobutamine administration were used. To exclude the effects of left ventricular function and morphology, a stone removal basket catheter was placed in the left ventricular outflow tract, and haemodynamics were compared with the basket closed and opened. The basket was opened five times in three dogs not showing systolic anterior motion-septal contact, but the basket itself did not effect the haemodynamics. In the seven dogs that showed systolic anterior motion-septal contact without left ventricular hypertrophy, the basket was opened a total of 33 times in the presence of various degrees of systolic anterior motion-septal contact. After opening the basket, systolic anterior motion was reduced echocardiographically, and significant (P<0.01) changes were observed in the left ventricle-aorta pressure gradient (from 68 +/- 22 to 25 +/- 15 mm Hg), the systolic ejection period (from 146 +/- 19 to 135 +/- 16 ms), and the stroke volume (SV; from 9.4 +/- 2.9 to 10.1 +/- 3.3 ml). After basket inflation, aortic pressure and aortic flow waveforms changed but the peak pressure and flow velocity did not. The temporal distribution of left ventricular ejection also definitely changed after the basket was opened. No changes were observed in the peak dp/dt, peak negative dp/dt, time constant, left ventricular end-diastolic pressure, or left atrial pressure. These observations in this animal model of systolic anterior motion without left ventricular hypertrophy suggest that: (1) there is no potential for generation of an intra-cavity gradient in the absence of systolic anterior motion of the mitral valve, so that (2) systolic anterior motion narrowed the left ventricular outflow tract and, consequently, produced the systolic ejection period, and affected the left ventricular ejection dynamics, and that (3) the basket catheter is useful because it allows these assessments in the same heart with a nearly fixed left ventricular contractility, at least in our animal model.
Fraser, Katharine H; Zhang, Tao; Taskin, M Ertan; Griffith, Bartley P; Wu, Zhongjun J
2010-01-01
Cannulation is necessary when blood is removed from the body, for example in hemodialysis, cardiopulmonary bypass, blood oxygenators, and ventricular assist devices. Artificial blood contacting surfaces are prone to thrombosis, especially in the presence of stagnant or recirculating flow. In this work, computational fluid dynamics was used to investigate the blood flow fields in three clinically available cannulae (Medtronic DLP 12, 16 and 24 F), used as drainage for pediatric circulatory support, and to calculate parameters which may be indicative of thrombosis potential. The results show that using the 24 F cannula below flow rates of about 0.75 l/min produces hemodynamic conditions which may increase the risk of blood clotting within the cannula. No reasons are indicated for not using the 12 or 16 F cannulae with flow rates between 0.25 and 3.0 l/min. PMID:20400890
Aerodynamic and acoustic effects of ventricular gap.
Alipour, Fariborz; Karnell, Michael
2014-03-01
Supraglottic compression is frequently observed in individuals with dysphonia. It is commonly interpreted as an indication of excessive circumlaryngeal muscular tension and ventricular medialization. The purpose of this study was to describe the aerodynamic and acoustic impact of varying ventricular medialization in a canine model. Subglottal air pressure, glottal airflow, electroglottograph, acoustic signals, and high-speed video images were recorded in seven excised canine larynges mounted in vitro for laryngeal vibratory experimentation. The degree of gap between the ventricular folds was adjusted and measured using sutures and weights. Data were recorded during phonation when the ventricular gap was narrow, neutral, and large. Glottal resistance was estimated by measures of subglottal pressure and glottal flow. Glottal resistance increased systematically as ventricular gap became smaller. Wide ventricular gaps were associated with increases in fundamental frequency and decreases in glottal resistance. Sound pressure level did not appear to be impacted by the adjustments in ventricular gap used in this research. Increases in supraglottic compression and associated reduced ventricular width may be observed in a variety of disorders that affect voice quality. Ventricular compression may interact with true vocal fold posture and vibration resulting in predictable changes in aerodynamic, physiological, acoustic, and perceptual measures of phonation. The data from this report supports the theory that narrow ventricular gaps may be associated with disordered phonation. In vitro and in vivo human data are needed to further test this association. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Liu, Ying; Zhang, Haowei; Zhang, Hang
2015-12-01
The early damage detection and evaluation are of great significance in treatment and prognosis to the left ventricular function for children with tumor. In this paper, it is reported that the early damage of the left ventricular function was observed by pulsed wave Doppler (PWD) and tissue Doppler imaging (TDI) in our laboratory. Eighty children half a year to fourteen years old were included in this study. The cardiac function indices in chemotherapy group and control group were measured and compared. The results showed that there was significant difference in mitral and tricuspid annulus flow spectrum between the two groups. Compared with PWD,TDI is more prompt, objective and accurate in detecting early damage of left ventricular function in children with tumor. And TDI is a good method for early identification of ventricular function damage in children with tumor.
VENTRICULAR SEPTAL DEFECT IN A CRAB-EATING FOX (CERDOCYON THOUS).
Sousa, Marlos Gonçalves; de Córdova, Fabiano Mendes; Ramos, Adriano Tony; Viana, Eduardo Borges; de Castro Conti, Laura Monteiro
2016-06-01
Congenital heart diseases are not commonly diagnosed in wild animals. It is not surprising that few reports exist in the literature, so that prevalence of these anomalies is unknown in wild species. We report a case of a ventricular septal defect documented in a free-ranging crab-eating fox (Cerdocyon thous). This animal presented with rapid, labored breathing, and on physical examination, pulmonary crackles and a holosystolic murmur were auscultated. The echocardiogram with Doppler showed discontinuity of the dorsal section of the ventricular septum, which allowed a turbulent systolic flow to move from the left to the right ventricle. The postmortem examination confirmed the absence of a dorsal connection between the septum and the atrioventricular junction, and pronounced left ventricular myocardial dilation was observed on histopathology. To the authors' knowledge, this is the first report of a perimembranous ventricular septal defect in a crab-eating fox.
Ukwatta, Eranga; Arevalo, Hermenegild; Li, Kristina; Yuan, Jing; Qiu, Wu; Malamas, Peter; Wu, Katherine C.
2016-01-01
Accurate representation of myocardial infarct geometry is crucial to patient-specific computational modeling of the heart in ischemic cardiomyopathy. We have developed a methodology for segmentation of left ventricular (LV) infarct from clinically acquired, two-dimensional (2D), late-gadolinium enhanced cardiac magnetic resonance (LGE-CMR) images, for personalized modeling of ventricular electrophysiology. The infarct segmentation was expressed as a continuous min-cut optimization problem, which was solved using its dual formulation, the continuous max-flow (CMF). The optimization objective comprised of a smoothness term, and a data term that quantified the similarity between image intensity histograms of segmented regions and those of a set of training images. A manual segmentation of the LV myocardium was used to initialize and constrain the developed method. The three-dimensional geometry of infarct was reconstructed from its segmentation using an implicit, shape-based interpolation method. The proposed methodology was extensively evaluated using metrics based on geometry, and outcomes of individualized electrophysiological simulations of cardiac dys(function). Several existing LV infarct segmentation approaches were implemented, and compared with the proposed method. Our results demonstrated that the CMF method was more accurate than the existing approaches in reproducing expert manual LV infarct segmentations, and in electrophysiological simulations. The infarct segmentation method we have developed and comprehensively evaluated in this study constitutes an important step in advancing clinical applications of personalized simulations of cardiac electrophysiology. PMID:26731693
Schönberger, Markus; Deutsch, Steven; Manning, Keefe B
2012-01-01
Ventricular assist devices are a commonly used heart failure therapy for adult patients as bridge-to-transplant or bridge-to-recovery tools. The application of adult ventricular assist devices in pediatric patients has led to increased thrombotic events. Therefore, we have been developing a pediatric ventricular assist device (PVAD), the Penn State 12 cc PVAD. It is designed for patients with a body weight of 5-15 kg and has a stroke volume of 12 cc. Clot formation is the major concern. It is correlated to the coagulability of blood, the blood contacting materials and the fluid dynamics within the system. The intent is for the PVAD to be a long term therapy. Therefore, the system may be oriented in different positions according to the patient's behavior. This study evaluates for the first time the impact of position on the flow patterns within the Penn State 12 cc PVAD, which may help to improve the PVAD design concerning chamber and ports geometries. The fluid dynamics are visualized by particle image velocimetry. The evaluation is based on inlet jet behavior and calculated wall shear rates. Vertical and horizontal model orientations are compared, both with a beat rate of 75, outlet pressures of 90/60 mm Hg and a flow rate of 1.3 l/min. The results show a significant change of the inlet jet behavior and the development of a rotational flow pattern. Vertically, the inlet jet is strong along the wall. It initiates a rotational flow pattern with a wandering axis of rotation. In contrast, the horizontal model orientation results show a weaker inlet jet along the wall with a nearly constant center of rotation location, which can be correlated to a higher risk of thrombotic events. In addition, high speed videography illustrates differences in the diaphragm motion during diastole. Diaphragm opening trajectories measurements determine no significant impact of the density of the blood analog fluids. Hence, the results correlate to human blood.
Probe for production and measurement of acute mitral regurgitant flow in dog.
Kléber, A G; Simon, R; Rutishauser, W
1976-02-01
A probe for production and measurement of acute mitral regurgitation in dogs is described. It consists of a tube that is introduced into the mitral valve through the left atrial appendage. Regurgitant flow through the tube is measured by an electromagnetic device. Variation of flow and zero flow are achieved by narrowing or occluding the tube with a rubber cuff. In animals weighing 30-50 kg, the probe does not produce significant mitral stenosis and the mitral leaflets fit closely around the probe during ventricular systole. The instantaneous relationship between mitral regurgitant flow (MRF) and the gradient between left ventricular and left atrial pressure shows a marked delay of MRF at the beginning and end of regurgitation. This delay can be attributed to some extent to electrical phase lag and to the small movement of the probe relative to the mitral valve during the cardiac cycle. Measurement of regurgitant stroke volume is affected by this movement only to a small extent.
Transthoracic Ultrafast Doppler Imaging of Human Left Ventricular Hemodynamic Function
Osmanski, Bruno-Félix; Maresca, David; Messas, Emmanuel; Tanter, Mickael; Pernot, Mathieu
2016-01-01
Heart diseases can affect intraventricular blood flow patterns. Real-time imaging of blood flow patterns is challenging because it requires both a high frame rate and a large field of view. To date, standard Doppler techniques can only perform blood flow estimation with high temporal resolution within small regions of interest. In this work, we used ultrafast imaging to map in 2D human left ventricular blood flow patterns during the whole cardiac cycle. Cylindrical waves were transmitted at 4800 Hz with a transthoracic phased array probe to achieve ultrafast Doppler imaging of the left ventricle. The high spatio-temporal sampling of ultrafast imaging permits to rely on a much more effective wall filtering and to increase sensitivity when mapping blood flow patterns during the pre-ejection, ejection, early diastole, diastasis and late diastole phases of the heart cycle. The superior sensitivity and temporal resolution of ultrafast Doppler imaging makes it a promising tool for the noninvasive study of intraventricular hemodynamic function. PMID:25073134
Diastolic blood pressure-estimated left ventricular dp/dt.
Yilmaz, Hüseyin; Minareci, Kenan; Kabukçu, Mehmet; Sancaktar, Oktay
2002-02-01
Peak dp/dt is one of the best isovolumic phase indexes of the myocardial contractile state requiring invasive procedures or presence of mitral regurgitation severe enough to measure in clinical practice by Doppler echocardiography. In this study, we sought the correlation between two noninvasive methods of measurements for left ventricular dp/dt-diastolic blood pressure- (DBP) estimated and continuous-wave Doppler-derived dp/dt-min electrocardiographic/echocardiographic study to emphasize the clinical feasibility of the DBP-estimated method. Thirty-six randomized patients (27 male, 9 female; 58 +/- 8 years) with mild mitral regurgitation were enrolled in this study. DBP-estimated dp/dt was calculated from DBP minus the left ventricular end-diastolic pressure (LVEDP) over the isovolumetric contraction time (IVCT). LVEDP was assumed to be 10 mmHg for all patients. Doppler-determined left ventricular dp/dt was derived from the continuous-wave Doppler spectrum of mitral regurgitation jet by dividing the magnitude of the left ventricular atrial pressure gradient rise between 1 mm/sec-3 mm/sec of mitral regurgitant velocity signal by the time taken for this change. Left ventricular dp/dt by Doppler was 1122 +/- 303 mmHg/sec and blood pressure-estimated dp/dt was 1063 +/- 294 mmHg/sec. There was a high correlation (r = 0.97, P < 0.001) of dp/dt between the two techniques. DBP and IVCT can generate left ventricular dp/dt without invasive procedures, even in the absence of mitral regurgitation in clinical practice.
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Van Herck, P L; Carlier, S G; Claeys, M J; Haine, S E; Gorissen, P; Miljoen, H; Bosmans, J M; Vrints, C J
2007-01-01
Objective To investigate the underlying mechanisms of a decreased coronary flow reserve after myocardial infarction (MI) by analysing the characteristics of the diastolic hyperaemic coronary pressure–flow relationship. Design Prospective study. Setting Tertiary care hospital. Patients 68 patients with a recent MI and 27 patients with stable angina pectoris (AP; control group). Main outcome measures The intercept with the pressure axis (the zero flow pressure or Pzf) and slope index of the pressure–flow relationship (SIPF) were calculated from the simultaneously recorded hyperaemic intracoronary blood flow velocity and aortic pressure after successful coronary stenting. Results A stepwise increase in Pzf from AP (14.6 (8.0) mm Hg), over non‐Q‐wave MI (22.5 (9.1) mm Hg), to Q‐wave MI (37.1 (12.9) mm Hg; p<0.001) was observed. Similar changes in Pzf were found in a reference artery perfusing the non‐infarcted myocardium. Multivariate analysis showed that in both regions the left ventricular end‐diastolic pressure (LVEDP) was the most important determinant of the Pzf. The SIPF was not statistically different in the treated vessel between patients with MI and AP, but was increased in MI patients with a markedly increased LVEDP. Conclusions After an MI, the coronary pressure–flow relationship is shifted to the right both in the infarcted and in the non‐infarcted remote myocardium, as shown by the increased Pzf. The correlation with Pzf suggests that elevated left ventricular filling pressures contribute to the impediment of myocardial perfusion in patients with infarction. PMID:17395671
Ion beam sputter-etched ventricular catheter for hydrocephalus shunt
NASA Technical Reports Server (NTRS)
Banks, B. A. (Inventor)
1983-01-01
A cerebrospinal fluid shunt in the form of a ventricular catheter for controlling the condition of hydrocephalus by relieving the excessive cerebrospinal fluid pressure is described. A method for fabrication of the catheter and shunting the cerebral fluid from the cerebral ventricles to other areas of the body is also considered. Shunt flow failure occurs if the ventricle collapse due to improper valve function causing overdrainage. The ventricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large openings at its inlet end and a multiplicity of microscopic openings along its lateral surfaces.
Simko, Fedor; Pechanova, Olga; Pelouch, Vaclav; Krajcirovicova, Kristina; Celec, Peter; Palffy, Roland; Bednarova, Kristina; Vrankova, Stanislava; Adamcova, Michaela; Paulis, Ludovit
2010-09-01
Blood pressure enhancement induced by continuous light exposure represents an attractive but rarely investigated model of experimental hypertension. The aim of this study was to show whether the combination of continuous light (24 h/day) exposure and chronic N-nitro-L-arginine-methyl ester (L-NAME) treatment induces remodelling of the left ventricle and whether captopril or melatonin can modify these potential alterations. Six groups of 3-month-old Wistar rats (nine per group) were treated for 6 weeks: control (untreated), L-NAME (40 mg/kg per day), exposed to continuous light, L-NAME treated and exposed to continuous light (L24), L24 rats treated with either captopril 100 mg/kg per day, or melatonin (10 mg/kg/24 h). Systolic blood pressure (SBP), relative weights of the left ventricle, endothelial nitric oxide synthase (eNOS) and angiotensin-converting enzyme (ACE) expression in tissues, malondialdehyde and advanced oxidation protein product concentrations in the plasma and hydroxyproline levels in collagenous protein fractions were measured. The continuous light and L-NAME treatment led to hypertension, left ventricular hypertrophy (LVH) and fibrosis. An increase in SBP was completely prevented by captopril and partly by melatonin in the L24 group. Both drugs reduced oxidative damage and attenuated enhanced expression of ACE in the myocardium. Neither of the drugs prevented the attenuation of eNOS expression in the combined hypertensive model. Only captopril reduced LVH development in L24, whereas captopril and melatonin reduced left ventricular hydroxyproline concentrations in soluble and insoluble collagen, respectively. The total hydroxyproline concentration was reduced only by melatonin. In hypertension induced by a combination of continuous light and L-NAME treatment, melatonin and captopril protect the heart against pathological left ventricular remodelling differently.
Verma, Sean; Bassily, Emmanuel; Leighton, Shane; Mhaskar, Rahul; Sunjic, Igor; Martin, Angel; Rihana, Nancy; Jarmi, Tambi; Bassil, Claude
2017-07-01
Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer's exact at the significance level of 0.05. Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period.
Myocardial oxygen delivery after experimental hemorrhagic shock.
Archie, J P; Mertz, W R
1978-01-01
The two components of myocardial oxygen delivery, coronary blood flow to capillaries and diffusion from capillaries to mitochondria, were studied in six dogs, (1) prior to shock, (2) after three hours of hemorrhage shock at a mean systemic arterial pressure of 40 torr, (3) after reinfusion of shed blood, and (4) during the irreversible late posttransfusion stage. There was a maldistribution of left ventricular coronary flow during late shock consistent with subendocardial ischemia. Cardiac performance was significantly impaired after resuscitation and all dogs became irreversible. Total and regional left ventricular coronary blood flow and myocardial oxygen delivery to capillaries were significantly greater than preshock values in (3) but not different from preshock values in (4). However, the myocardial oxygen diffusion area to distance ratio was significantly lower than preshock values in (3), and slightly lower in (4). These data suggest that myocardial oxygen diffusion may be impaired in the early post transfusion period, (3). Accordingly, the probable etiology of left ventricular dysfunction and possibly irreversibility after resuscitation from hemorrhagic shock is subendocardial ischemia during shock with either post-resuscitation impairment of myocardial oxygen diffusion, or in cellular oxygen utilization, or both. PMID:629622
Voelker, W; Reul, H; Nienhaus, G; Stelzer, T; Schmitz, B; Steegers, A; Karsch, K R
1995-02-15
Valvular resistance and stroke work loss have been proposed as alternative measures of stenotic valvular lesions that may be less flow dependent and, thus, superior over valve area calculations for the quantification of aortic stenosis. The present in vitro study was designed to compare the impacts of valvular resistance, stroke work loss, and Gorlin valve area as hemodynamic indexes of aortic stenosis. In a pulsatile aortic flow model, rigid stenotic orifices in varying sizes (0.5, 1.0, 1.5 and 2.0 cm2) and geometry were studied under different hemodynamic conditions. Ventricular and aortic pressures were measured to determine the mean systolic ventricular pressure (LVSPm) and the transstenotic pressure gradient (delta Pm). Transvalvular flow (Fm) was assessed with an electromagnetic flowmeter. Valvular resistance [VR = 1333.(delta Pm/Fm)] and stroke work loss [SWL = 100.(delta Pm/LVSPm)] were calculated and compared with aortic valve area [AVA = Fm/(50 square root of delta Pm)]. The measurements were performed for a large range of transvalvular flows. At low-flow states, flow augmentation (100-->200 mL/s) increased calculated valvular resistance between 21% (2.0 cm2 orifice) and 66% (0.5-cm2 orifice). Stroke work loss demonstrated an increase from 43% (2.0 cm2) to 100% (1.0 cm2). In contrast, Gorlin valve area revealed only a moderate change from 29% (2.0 cm2) to 5% (0.5 cm2). At physiological flow rates, increase in transvalvular flow (200-->300 mL/s) did not alter calculated Gorlin valve area, whereas valvular resistance and stroke work loss demonstrated a continuing increase. Our experimental results were adopted to interpret the results of three clinical studies in aortic stenosis. The flow-dependent increase of Gorlin valve area, which was found in the cited clinical studies, can be elucidated as true further opening of the stenotic valve but not as a calculation error due to the Gorlin formula. Within the physiological range of flow, calculated aortic valve area was less dependent on hemodynamic conditions than were valvular resistance and stroke work loss, which varied as a function of flow. Thus, for the assessment of the severity of aortic stenosis, the Gorlin valve area is superior over valvular resistance and stroke work loss, which must be indexed for flow to adequately quantify the hemodynamic severity of the obstruction.
Magalang, Ulysses J.; Richards, Kathryn; McCarthy, Beth; Fathala, Ahmed; Khan, Meena; Parinandi, Narasimham; Raman, Subha V.
2009-01-01
Study Objectives. There are few data on the effects of continuous positive airway pressure (CPAP) therapy on the structural and functional characteristics of the right heart in patients with obstructive sleep apnea (OSA). We sought to leverage the advantages of cardiac magnetic resonance imaging (CMR) and hypothesized that CPAP treatment would improve right ventricular (RV) function in a group of patients with OSA who were free of other comorbid conditions. Methods. Patients with severe (apnea-hypopnea index ≥ 30/h) untreated OSA were prospectively enrolled. CMR included 3-dimensional measurement of biventricular size and function, and rest/stress myocardial perfusion and was performed at baseline and after 3 months of CPAP therapy. Results. Fifteen patients with mild to moderate desaturation were enrolled; 2 could not undergo CMR due to claustrophobia and obesity. There were significant decreases in the Epworth Sleepiness Scale score (p < 0.0001) and RV end-systolic and RV end-diastolic volumes (p < 0.05) with CPAP. There was a trend toward improvement in RV ejection fraction, but the improvement did not reach statistical significance. Other measures such as left ventricular volumes, left ventricular ejection fraction, myocardial perfusion reserve index, and thickness of the interventricular septum and ventricular free wall did not change significantly. Conclusions: This preliminary study found that CPAP treatment decreases RV volumes in patients with severe OSA who are otherwise healthy. CMR offers a novel technique to determine the effects of CPAP on ventricular structure and function in patients with OSA. A randomized controlled study is needed to confirm the results of our study. Citation: Magalang UJ; Richards K; McCarthy B; Fathala A; Khan M; Parinandi N; Raman SV. Continuous positive airway pressure therapy reduces right ventricular volume in patients with obstructive sleep apnea: a cardiovascular magnetic resonance study. J Clin Sleep Med 2009;5(2):110-114. PMID:19968042
Tripathi, Mukesh; Kaushik, Soma; Pandey, Rajesh
2006-11-01
Progressive hyperkalaemia is common in end stage renal disease patients waiting for renal transplantation. Ventricular tachycardia and ventricular fibrillation due to hyperkalaemia are life-threatening complications in these patients. In live and related renal transplant, after induction and anaesthesia, ventricular fibrillation and pulmonary oedema occurred. After immediate resuscitation by defibrillation and intravenous injection of adrenaline, the patient was put on continuous femoral arteriovenous haemofiltration (CAVH). This improved his pulmonary oedema, controlled hyperkalaemia and surgery could be completed uninterruptedly. After anaesthetising live and related kidney donor for nephrectomy, since it is not prudent to stop recipient surgery because of unforeseen complication, the authors wish to recommend CAVH as an alternative method to prevent life threatening cardiac complication of hyperkalaemia.
Neilan, Tomas G.; Farhad, Hoshang; Dodson, John A.; Shah, Ravi V.; Abbasi, Siddique A.; Bakker, Jessie P.; Michaud, Gregory F.; van der Geest, Rob; Blankstein, Ron; Steigner, Michael; John, Roy M.; Jerosch‐Herold, Michael; Malhotra, Atul; Kwong, Raymond Y.
2013-01-01
Background Sleep apnea (SA) is associated with an increased risk of atrial fibrillation (AF). We sought to determine the effect of SA on cardiac structure in patients with AF, whether therapy for SA was associated with beneficial cardiac structural remodelling, and whether beneficial cardiac structural remodelling translated into a reduced risk of recurrence of AF after pulmonary venous isolation (PVI). Methods and Results A consecutive group of 720 patients underwent a cardiac magnetic resonance study before PVI. Patients with SA (n=142, 20%) were more likely to be male, diabetic, and hypertensive and have an increased pulmonary artery pressure, right ventricular volume, atrial dimensions, and left ventricular mass. Treated SA was defined as duration of continuous positive airway pressure therapy of >4 hours per night. Treated SA patients (n=71, 50%) were more likely to have paroxysmal AF, a lower blood pressure, lower ventricular mass, and smaller left atrium. During a follow‐up of 42 months, AF recurred in 245 patients. The cumulative incidence of AF recurrence was 51% in patients with SA, 30% in patients without SA, 68% in patients with untreated SA, and 35% in patients with treated SA. In a multivariable model, the presence of SA (hazard ratio 2.79, CI 1.97 to 3.94, P<0.0001) and untreated SA (hazard ratio 1.61, CI 1.35 to 1.92, P<0.0001) were highly associated with AF recurrence. Conclusions Patients with SA have an increased blood pressure, pulmonary artery pressure, right ventricular volume, left atrial size, and left ventricular mass. Therapy with continuous positive airway pressure is associated with lower blood pressure, atrial size, and ventricular mass, and a lower risk of AF recurrence after PVI. PMID:24275628
NASA Technical Reports Server (NTRS)
Fogarty, Jennifer A.
2010-01-01
A NASA engineer received a heart transplant performed by Drs. DeBakey and Noon after suffering a serious heart attack. 6 months later that engineer returned to work at NASA determined to use space technology to help people with heart disease. A relationship between NASA and Drs. DeBakey and Noon was formed and the group worked to develop a low cost, low power implantable ventricular assist device (VAD). NASA patented the method to reduce pumping damage to red blood cells and the design of a continuous flow heart pump (#5,678,306 and #5,947,892). The technology and methodology were licensed exclusively to MicroMed Technology, Inc.. In late 1998 MicroMed received international quality and electronic certifications and began clinical trials in Europe. Ventricular assist devices were developed to bridge the gap between heart failure and transplant. Early devices were cumbersome, damaged red blood cells, and increased the risk of developing dangerous blood clots. Application emerged from NASA turbopump technology and computational fluid dynamics analysis capabilities. To develop the high performance required of the Space Shuttle main engines, NASA pushed the state of the art in the technology of turbopump design. NASA supercomputers and computational fluid dynamics software developed for use in the modeling analysis of fuel and oxidizer flow through rocket engines was used in the miniaturization and optimization of a very small heart pump. Approximately 5 million people worldwide suffer from chronic heart failure at a cost of 40 billion dollars In the US, more than 5000 people are on the transplant list and less than 3000 transplants are performed each year due to the lack of donors. The success of ventricular assist devices has led to an application as a therapeutic destination as well as a bridge to transplant. This success has been attributed to smaller size, improved efficiency, and reduced complications such as the formation of blood clots and infection.
Nascimbene, Angelo; Hernandez, Ruben; George, Joggy K; Parker, Anita; Bergeron, Angela L; Pradhan, Subhashree; Vijayan, K Vinod; Civitello, Andrew; Simpson, Leo; Nawrot, Maria; Lee, Vei-Vei; Mallidi, Hari R; Delgado, Reynolds M; Dong, Jing Fei; Frazier, O H
2014-05-01
Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p < 0.001), even though the 2 patient groups did not markedly differ in other clinical and hematologic parameters. Our results suggest that an elevation of PS+ microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
2014-01-01
Background Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. Objective To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. Design A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4–5 cmH2O) because they developed RDS within the first 24–72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH2O, Plow 4–5 cmH2O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. Results No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO2 levels after bi-level CPAP ventilation was observed; pCO2 variations did not correlate with modifications of central blood flow (LVO: ρ = 0.11, p = 0,657; RVO: ρ = −0.307, p = 0.216; SVC: ρ = −0.13, p = 0.197). Conclusions Central blood flow doesn’t change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants. PMID:24952579
Yokoyama, Yoshimasa; Kawaguchi, Osamu; Kitao, Takashi; Kimura, Taro; Steinseifer, Ulrich; Takatani, Setsuo
2010-09-01
The ventricular performance is dependent on the drainage effect of rotary blood pumps (RBPs) and the performance of RBPs is affected by the ventricular pulsation. In this study, the interaction between the ventricle and RBPs was examined using the pressure-volume (P-V) diagram of the ventricle and dynamic head pressure-bypass flow (H-Q) curves (H, head pressure: arterial pressure minus ventricular pressure vs. Q, bypass flow) of the RBPs. We first investigated the relationships in a mock loop with a passive fill ventricle, followed by validation in ex vivo animal experiments. An apical drainage cannula with a micro-pressure sensor was especially fabricated to obtain ventricular pressure, while three pairs of ultrasonic crystals placed on the heart wall were used to derive ventricular volume. The mock loop-configured ventricular apical-descending aorta bypass revealed that the external work of the ventricle expressed by the area inside the P-V diagrams (EW(Heart) ) correlated strongly with the area inside dynamic H-Q curves (EW(VAD)), with the coefficients of correlation being R² = 0.869 ∼ 0.961. The results in the mock loop were verified in the ex vivo studies using three Shiba goats (10-25 kg in body weight), showing the correlation coefficients of R² = 0.802 ∼ 0.817. The linear regression analysis indicated that the increase in the bypass flow reduced pulsatility in the ventricle expressed in EW(Heart) as well as in EW(VAD) . Experimental results, both mock loop and animal studies, showed that the interaction between cardiac external work and H-Q performance of RBPs can be expressed by the relationships "EW(Heart) versus EW(VAD) ." The pulsatile nature of the native heart can be expressed in the area underneath the H-Q curves of RBPs EW(VAD) during left heart bypass indicating the status of the level of assistance by RBPs and the native heart function. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Cardiovascular studies using the chimpanzee (Pan troglodytes)
NASA Technical Reports Server (NTRS)
Hinds, J. E.; Cothran, L. N.; Hawthorne, E. W.
1977-01-01
Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.
Markus, Marcello Ricardo Paulista; Stritzke, Jan; Lieb, Wolfgang; Mayer, Björn; Luchner, Andreas; Döring, Angela; Keil, Ulrich; Hense, Hans-Werner; Schunkert, Heribert
2008-10-01
It is unclear whether persistent prehypertension causes structural or functional alterations of the heart. We examined echocardiographic data of 1005 adults from a population-based survey at baseline in 1994/1995 and at follow-up in 2004/2005. We compared individuals who had either persistently normal (<120 mmHg systolic and <80 mmHg diastolic, n = 142) or prehypertensive blood pressure (120-139 mmHg or 80-89 mmHg, n = 119) at both examinations using multivariate regression modeling. Over 10 years, left ventricular end-diastolic diameters were stable and did not differ between the two groups. However, the prehypertensive blood pressure group displayed more pronounced ageing-related increases of left ventricular wall thickness (+4.7 versus +11.9%, P < 0.001) and left ventricular mass (+8.6 versus +15.7%, P = 0.006). Prehypertension was associated with a raised incidence of left ventricular concentric remodeling (adjusted odds ratio 10.7, 95% confidence interval 2.82-40.4) and left ventricular hypertrophy (adjusted odds ratio 5.33, 1.58-17.9). The ratio of early and late diastolic peak transmitral flow velocities (E/A) decreased by 7.7% in the normal blood pressure versus 15.7% in the prehypertensive blood pressure group (P = 0.003) and at follow-up the ratio of early diastolic peak transmitral flow and early diastolic peak myocardial relaxation velocities (E/EM) was higher (9.1 versus 8.5, P = 0.031) and left atrial size was larger (36.5 versus 35.3 mm, P = 0.024) in the prehypertensive blood pressure group. Finally, the adjusted odds ratio for incident diastolic dysfunction was 2.52 (1.01-6.31) for the prehypertensive blood pressure group. Persistent prehypertension accelerates the development of hypertrophy and diastolic dysfunction of the heart.
Kutty, Shelby; Li, Ling; Danford, David A; Houle, Helene; Datta, Saurabh; Mancina, Joel; Xiao, Yunbin; Pedrizzetti, Gianni; Porter, Thomas R
2014-12-01
The purpose of this investigation was to test the hypothesis that flow patterns in the right ventricle are abnormal in patients with repaired tetralogy of Fallot (TOF). High-resolution echocardiographic contrast particle imaging velocimetry was used to investigate rotation intensity and kinetic energy dissipation of right ventricular (RV) flow in patients with TOF compared with normal controls. Forty-one subjects (16 with repaired TOF and varying degrees of RV dilation and 25 normal controls) underwent prospective contrast imaging using the lipid-encapsulated microbubble (Definity) on Sequoia systems. A mechanical index of 0.4, three-beat high-frame rate (>60 Hz) captures, and harmonic frequencies were used. Rotation intensity and kinetic energy dissipation of flow in the right and left ventricles were studied (Hyperflow). Ventricular volumes and ejection fractions in all subjects were derived from same-day cardiac magnetic resonance (CMR). Measurable planar maps were obtained for the left ventricle in 14 patients and the right ventricle in 10 patients among those with TOF and for the left ventricle in 23 controls and the right ventricle in 21 controls. Compared with controls, the TOF group had higher RV indexed end-diastolic volumes (117.8 ± 25.5 vs 88 ± 15.4 mL/m(2), P < .001) and lower RV ejection fractions (44.6 ± 3.6% vs 51.8 ± 3.6%, P < .001). Steady-streaming (heartbeat-averaged) flow rotation intensities were higher in patients with TOF for the left ventricle (0.4 ± 0.13 vs 0.29 ± 0.08, P = .012) and the right ventricle (0.53 ± 0.15 vs 0.26 ± 0.12, P < .001), whereas kinetic energy dissipation in TOF ventricles was lower (for the left ventricle, 0.51 ± 0.29 vs 1.52 ± 0.69, P < .001; for the right ventricle, 0.4 ± 0.24 vs 1.65 ± 0.91, P < .001). It is feasible to characterize RV and left ventricular flow parameters and planar maps in adolescents and adults with repaired TOF using echocardiographic contrast particle imaging velocimetry. Intraventricular flow patterns in the abnormal and/or enlarged right ventricle in patients with TOF differ from those in normal young adults. The rotation intensity and energy dissipation trends in this investigation suggest that they may be quantitative markers of RV and left ventricular compliance abnormalities in patients with repaired TOF. This hypothesis merits further investigation. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Right Heart Vortex Entrainment Volume and Right Ventricular Diastolic Dysfunction
NASA Astrophysics Data System (ADS)
Browning, James; Hertzberg, Jean; Fenster, Brett; Schroeder, Joyce
2014-11-01
Recent advances in cardiac magnetic resonance imaging (CMR) have allowed for the 3-dimensional characterization of blood flow in the right ventricle (RV) and right atrium (RA). In this study, we investigate and quantify differences in the characteristics of coherent rotating flow structures (vortices) in the RA and RV between subjects with right ventricular diastolic dysfunction (RVDD) and normal controls. Fifteen RVDD subjects and 10 age-matched controls underwent same day 3D time resolved CMR and echocardiography. Echocardiography was used to determine RVDD stage as well as pulmonary artery systolic pressure (PASP). CMR data was used for RA and RV vortex quantification and visualization during early and late ventricular diastole. RA and RV vortex entrainment volume is quantified and visualized using the Lambda-2 criterion, and the results are compared between healthy subjects and those with RVDD. The resulting trends are discussed and hypotheses are presented regarding differences in vortex characteristics between healthy and RVDD subjects cohorts.
77-year-old female with syncope.
Abdelsalam, Mahmoud A; Geske, Jeffrey B
2017-02-15
A 77-year-old female was referred for evaluation of an episode of syncope while eating breakfast. There was no history of fall, syncope, prodrome, dyspnoea, chest discomfort or palpitations. Medical history was notable for hyperlipidaemia and treated hypertension. Blood pressure was 140/90 mm Hg, pulse 85 beats per minute (BPM). No murmurs were present on cardiac examination. ECG revealed normal sinus rhythm with left ventricular (LV) hypertrophy (see online supplementary figure S1). Holter monitor demonstrated rare premature ventricular complexes (<1% of beats), without heart block or ventricular tachycardia. Transthoracic echocardiogram is shown in figure 1. Which of the following is the explanation for the flow indicated by the yellow arrow? Aortic stenosisCoronary artery flow, indicative of coronary fistulaHypertrophic cardiomyopathy with apical pouchHypertensive heart diseaseMitral stenosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Aortic Wave Dynamics and Its Influence on Left Ventricular Workload
Pahlevan, Niema M.; Gharib, Morteza
2011-01-01
The pumping mechanism of the heart is pulsatile, so the heart generates pulsatile flow that enters into the compliant aorta in the form of pressure and flow waves. We hypothesized that there exists a specific heart rate at which the external left ventricular (LV) power is minimized. To test this hypothesis, we used a computational model to explore the effects of heart rate (HR) and aortic rigidity on left ventricular (LV) power requirement. While both mean and pulsatile parts of the pressure play an important role in LV power requirement elevation, at higher rigidities the effect of pulsatility becomes more dominant. For any given aortic rigidity, there exists an optimum HR that minimizes the LV power requirement at a given cardiac output. The optimum HR shifts to higher values as the aorta becomes more rigid. To conclude, there is an optimum condition for aortic waves that minimizes the LV pulsatile load and consequently the total LV workload. PMID:21853075
Chambers, J. B.; Monaghan, M. J.; Jackson, G.
1988-01-01
Imaging echocardiography is an important extension of the clinical examination and will answer most questions in an emergency-for example, whether an enlarged cardiac shadow on the chest radiograph represents ventricular dilatation or an effusion. Doppler ultrasonography is essential for hospitals with an interest in cardiology because it provides direct haemodynamic data that are complementary to imaging. It requires more skill than imaging and may also be time consuming. Colour flow Doppler mapping is speedy and simple to use and aids the interpretation of continuous wave Doppler. It is therefore a natural companion to conventional Doppler, but there would have to be a high clinical load to justify its purchase. Images FIG 3 FIG 4 FIG 4 FIG 5 FIG 6 PMID:3143434
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera Sole, Ricardo
Objective: The main objective of this study was to evaluate the effects of the treatment with eprosartan on cardiac hypertrophy in hypertensive patients using the echocardiogram to measure the hypertrophy of left ventricle. We studied 60 untreated patients diagnosed of mild to moderate hypertension which received after the diagnosis 600 mg/day of eprosartan, a novel direct angiotensin inhibitor recently introduced to treat hypertension. All patients were submitted to a standard echocardiographic study before the treatment and after 6 months of it We evaluated by echocardiogram the following parameters: left ventricular septum and posterior wall thickness, left ventricular mass, E/A indexmore » of mitral flow considering abnormal when this index was less than 1, and left ventricular ejection fraction. Results: at the beginning we found a systolic/diastolic pressures of 165{+-}9/ 96{+-}4 mmHg compared with the end of study of 124{+-}2/79{+-}3 mmHg (p<0.05). Septum and posterior wall thickness were respectively at baseline 13.2{+-}2 and 12.1{+-}1.1 mmHg and at the end 11.5{+-}1.2 and 10.5{+-}1.3 mmHg (p<0.05 for both of them). The E/A mitral flow index was less than 1 at baseline in 45 patients compared with 19 patients after treatment (p<0.05). Respect to left ventricular mass we found at the beginning 232{+-}7.5 gr., compared to 194{+-}9 gr., at the end of this study (p<0.05). We did not find any significant differences regarding left ventricular ejection fraction between both groups. Conclusions: we can remark that eprosartan is a very useful drug to reduce not only blood pressure but also left ventricular hypertrophy and improve left ventricular diastolic function in patients with essential hypertension according with parameters measured with non invasive methods.« less
Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.
Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael
2016-01-01
In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Hallbergson, Anna; Esch, Jesse J; Tran, Trang X; Lock, James E; Marshall, Audrey C
2016-10-01
We have taken a novel approach using oral rapamycin - sirolimus - as a medical adjunct to percutaneous therapy in patients with in-stent stenosis and high risk of right ventricular failure. Peripheral pulmonary artery stenosis can result in right ventricular hypertension, dysfunction, and death. Percutaneous pulmonary artery angioplasty and stent placement acutely relieve obstructions, but patients frequently require re-interventions due to re-stenosis. In patients with tetralogy of Fallot or arteriopathy, the problem of in-stent stenosis contributes to the rapidly recurrent disease. Rapamycin was administered to 10 patients (1.5-18 years) with peripheral pulmonary stenosis and in-stent stenosis and either right ventricular hypertension, pulmonary blood flow maldistribution, or segmental pulmonary hypertension. Treatment was initiated around the time of catheterisation and continued for 1-3 months. Potential side-effects were monitored by clinical review and blood tests. Target serum rapamycin level (6-10 ng/ml) was accomplished in all patients; eight of the nine patients who returned for clinically indicated catheterisations demonstrated reduction in in-stent stenosis, and eight of the 10 patients experienced no significant side-effects. Among all, one patient developed diarrhoea requiring drug discontinuation, and one patient experienced gastrointestinal bleeding while on therapy that was likely due to an indwelling feeding tube and this patient tolerated rapamycin well following tube removal. Our initial clinical experience supports that patients with peripheral pulmonary artery stenosis can be safely treated with rapamycin. Systemic rapamycin may provide a novel medical approach to reduce in-stent stenosis.
Blood Pump Development Using Rocket Engine Flow Simulation Technology
NASA Technical Reports Server (NTRS)
Kwak, Dochan; Kiris, Cetin
2001-01-01
This paper reports the progress made towards developing complete blood flow simulation capability in humans, especially in the presence of artificial devices such as valves and ventricular assist devices. Devices modeling poses unique challenges different from computing the blood flow in natural hearts and arteries. There are many elements needed to quantify the flow in these devices such as flow solvers, geometry modeling including flexible walls, moving boundary procedures and physiological characterization of blood. As a first step, computational technology developed for aerospace applications was extended to the analysis and development of a ventricular assist device (VAD), i.e., a blood pump. The blood flow in a VAD is practically incompressible and Newtonian, and thus an incompressible Navier-Stokes solution procedure can be applied. A primitive variable formulation is used in conjunction with the overset grid approach to handle complex moving geometry. The primary purpose of developing the incompressible flow analysis capability was to quantify the flow in advanced turbopump for space propulsion system. The same procedure has been extended to the development of NASA-DeBakey VAD that is based on an axial blood pump. Due to massive computing requirements, high-end computing is necessary for simulating three-dimensional flow in these pumps. Computational, experimental, and clinical results are presented.
Hemodynamic Performance of a Novel Right Ventricular Assist Device (PERKAT).
Kretzschmar, Daniel; Schulze, P Christian; Ferrari, Markus W
Acute right ventricular failure (RVF) is an increasing clinical problem and a life-threatening condition. Right ventricular assist devices represent a reasonable treatment option for patients with refractory RVF. We here present a novel percutaneously implantable device for right ventricular support. The PERKAT device is based on a nitinol stent cage, which is covered with valve-carrying foils. A flexible outlet trunk with a pigtail tip is connected to the distal part. The device is driven by an intra-aortic balloon pump (IABP) drive unit, which inflates/deflates a standard IABP-balloon placed within the stent cage. In-vitro evaluation was done in a liquid bath containing water or blood analog. The PERKAT device was tested in different afterload settings using two different IABP-balloons and varying inflation/deflation rates. We detected flow rates ranging from 1.97 to 3.93 L/min depending on the afterload setting, inflation/deflation rate, balloon size, and the medium used. Flow rates between water and blood analog were nearly comparable, and in the higher inflation/deflation rate settings slightly higher with water. Based on this promising in vitro data, the innovative percutaneously implantable PERKAT device has a potential to become a therapeutic option for patients with RVF refractory to medical treatment.
Left ventricular structural and functional characteristics in Cushing's syndrome.
Muiesan, Maria Lorenza; Lupia, Mario; Salvetti, Massimo; Grigoletto, Consuelo; Sonino, Nicoletta; Boscaro, Marco; Rosei, Enrico Agabiti; Mantero, Franco; Fallo, Francesco
2003-06-18
This study was designed to evaluate left ventricular (LV) anatomy and function in patients with Cushing's syndrome. A high prevalence of LV hypertrophy and concentric remodeling has been reported in Cushing's syndrome, although no data have been reported on LV systolic and diastolic function. Forty-two consecutive patients with Cushing's syndrome and 42 control subjects, matched for age, gender, and blood pressure, were studied. Left ventricular mass index (LVMI) and relative wall thickness (RWT) were measured by echocardiography, endocardial and midwall fractional shortening (FS) were assessed, and diastolic filling was measured by Doppler transmitral flow. The RWT was significantly greater in Cushing patients than in controls. Left ventricular hypertrophy and concentric remodeling were observed in 10 and 26 patients with Cushing's syndrome, respectively. In Cushing patients, midwall FS was significantly reduced compared with controls (16.2 +/- 3% vs. 21 +/- 4.5%, p = 0.01). The ratio of transmitral E and A flow velocities was reduced and E deceleration time was prolonged in Cushing patients compared with controls (p = 0.03 and p < 0.001, respectively). In patients with Cushing's syndrome, cardiac structural changes are associated with reduced midwall systolic performance and with diastolic dysfunction that may contribute to the high risk of cardiovascular events observed in these patients.
Hydrocephalus secondary to obstruction of the lateral apertures in two dogs.
Kent, M; Glass, E N; Haley, A C; Shaikh, L S; Sequel, M; Blas-Machado, U; Bishop, T M; Holmes, S P; Platt, S R
2016-11-01
Traditionally, hydrocephalus is divided into communicating or non-communicating (obstructive) based on the identification of a blockage of cerebrospinal fluid (CSF) flow through the ventricular system. Hydrocephalus ex vacuo refers to ventricular enlargement as a consequence of neuroparenchymal loss. Hydrocephalus related to obstruction of the lateral apertures of the fourth ventricles has rarely been described. The clinicopathologic findings in two dogs with hydrocephalus secondary to obstruction of the lateral apertures of the fourth ventricle are reported. Signs were associated with a caudal cervical spinal cord lesion in one dog and a caudal brain stem lesion in the other dog. Magnetic resonance imaging (MRI) disclosed dilation of the ventricular system, including the lateral recesses of the fourth ventricle. In one dog, postmortem ventriculography confirmed obstruction of the lateral apertures. Microscopic changes were identified in the choroid plexus in both dogs, yet a definitive cause of the obstructions was not identified. The MRI findings in both dogs are similar to membranous occlusion of the lateral and median apertures in human patients. MRI detection of dilation of the entire ventricular system in the absence of an identifiable cause should prompt consideration of an obstruction of the lateral apertures. In future cases, therapeutic interventions aimed at re-establishing CSF flow or ventriculoperitoneal catheterisation should be considered. © 2016 Australian Veterinary Association.
Echocardiographic assessment of left ventricular diastolic function.
Pirat, Bahar; Zoghbi, William A
2007-09-01
Assessment of diastolic function and left ventricular filling pressures in the setting of both normal and reduced systolic function is of major importance particularly in patients with dyspnea. Since multiple echocardiography parameters are used to assess diastolic function each with some limitations, a comprehensive approach should be applied. Transmitral Doppler flow should be evaluated in combination with newer, less load dependent Doppler techniques. Tissue Doppler imaging provides accurate, well validated data regarding diastolic properties and filling pressures of the left ventricle. Tissue Doppler imaging should be the part of a routine echocardiography study due to its ease of use and high reproducibility. Pulmonary vein Doppler and flow propagation velocity should be incorporated into the evaluation when needed.
Mechanism of reduction of mitral regurgitation with vasodilator therapy.
Yoran, C; Yellin, E L; Becker, R M; Gabbay, S; Frater, R W; Sonnenblick, E H
1979-04-01
Acute mitral regurgitation was produced in six open chest dogs by excising a portion of the anterior valve leaflet. Electromagnetic flow probes were placed in the left atrium around the mitral anulus and in the ascending aorta to determine phasic left ventricular filling volume, regurgitant volume and stroke volume. The systolic pressure gradient was calculated from simultaneously measured high fidelity left atrial and left ventricular pressures. The effective mitral regurgitant orifice area was calculated from Gorlin's hydraulic equation. Infusion of nitroprusside resulted in a significant reduction in mitral regurgitation. No significant change occurred in the systolic pressure gradient between the left ventricle and the left atrium because both peak left ventricular pressure and left atrial pressure were reduced. The reduction of mitral regurgitation was largely due to reduction in the size of the mitral regurgitant orifice. Reduction of ventricular volume rather than the traditional concept of reduction of impedance of left ventricular ejection may explain the effects of vasodilators in reducing mitral regurgitation.
Jobe, A; Ikegami, M; Jacobs, H; Jones, S
1984-01-01
Prematurely delivered lambs were treated with radiolabeled natural surfactant by either tracheal instillation at birth and before the onset of mechanical ventilation, or after 23 +/- 1 (+/- SE) min of mechanical ventilation. Right ventricular blood flow distributions, left ventricular outputs, and left-to-right ductal shunts were measured with radiolabeled microspheres. After sacrifice, the lungs of lambs receiving surfactant at birth inflated uniformly with constant distending pressure while the lungs of lambs treated after a period of ventilation had aerated, partially aerated, and atelectatic areas. All lungs were divided into pieces which were weighed and catalogued as to location. The amount of radiolabeled surfactant and microsphere-associated radioactivity in each piece of lung was quantified. Surfactant was relatively homogenously distributed to pieces of lung from lambs that were treated with surfactant at birth; 48% of lung pieces received amounts of surfactant within +/- 25% of the mean value. Surfactant was preferentially recovered from the aerated pieces of lungs of lambs treated after a period of mechanical ventilation, and the distribution of surfactant to these lungs was very nonhomogeneous. Right ventricular blood flow distributions to the lungs were quite homogeneous in both groups of lambs. However, in 8 of 12 lambs, pulmonary blood flow was preferentially directed away from those pieces of lung that received relatively large amounts of surfactant and toward pieces of lung that received less surfactant. This acute redirection of pulmonary blood flow distribution may result from the local changes in compliances within the lung following surfactant instillation. PMID:6546766
Huber, Christoph H; Tozzi, Piergiorgio; Hurni, Michel; von Segesser, Ludwig K
2004-06-01
The new magnetically suspended axial pump is free of seals, bearings, mechanical friction and wear. In the absence of a drive shaft or flow meter, pump flow assessment is made with an algorithm based on currents required for impeller rotation and stabilization. The aim of this study is to validate pump performance, algorithm-based flow and effective flow. A series of bovine experiments was realized after equipment with pressure transducers, continuous-cardiac-output-catheter, intracardiac ultrasound (AcuNav) over 6 h. Pump implantation was through a median sternotomy (LV-->VAD-->calibrated transonic-flow-probe-->aorta). A transonic-HT311-flow-probe was fixed onto the outflow cannula for flow comparison. Animals were electively sacrificed and at necropsy systematic pump inspection and renal embolus score was realized. Observation period was 340+/-62.4 min. The axial pump generated a mean arterial pressure of 58.8+/-14.3 mmHg (max 117 mmHg) running at a speed of 6591.3+/-1395.4 rev./min (min 5000/max 8500 rev./min) and generating 2.5+/-1.0 l/min (min 1.4/max 6.0 l/min) of flow. Correlation between the results of the pump flow algorithm and measured pump flow was linear (y=1.0339x, R2=0.9357). VAD explants were free of macroscopic thrombi. Renal embolus score was 0+/-0. The magnetically suspended axial flow pump provides excellent left ventricular support. The pump flow algorithm used is accurate and reliable. Therefore, there is no need for direct flow measurement.
Radulescu, D; Buzdugan, E; Ciuleanu, T E; Todor, N; Stoicescu, L
2013-01-01
The aim of this study was to assess whether treatment with angiotensin converting enzyme inhibitors (ACEI) can prevent the alteration of left ventricular systolic and diastolic performance in cancer patients treated with different chemotherapy regimens containing epirubicin. In this prospective study , 68 patients with different malignant tumors treated with epirubicin and perindopril in different chemotherapy protocols (study group), and a gender- and age-matched group of 68 patients with different malignant tumors treated with epirubicin without perindopril in different chemotherapy protocols (control group), were assessed by Doppler echocardiography. Left ventricular systolic function was assessed by measuring left ventricular ejection fraction (EF). Left ventricular diastolic function was assessed by Doppler ultrasound by evaluating the transmitral flow. We also assessed the QTc on the 12 lead electrocardiograms. At the end of chemotherapy the left ventricular systolic function was less altered in the study group compared to the control group and was superior in the study group (epirubicin+ACEI) compared to the control group (epirubicin alone). We documented a significantly deteriorated left ventricular diastolic function in both groups at the completion of chemotherapy. QTc time in both arms was also significantly prolonged. In the present echo-Doppler study we documented a preserved left ventricular systolic performance in patients with various malignancies treated with epirubicin plus perindopril. Although co-treatment with ACEI prevented the alteration of systolic performance, it failed to prevent the deterioration of the left ventricular diastolic performance impairment due to poor left ventricular compliance.
Sugiyama, Atsushi; Takahara, Akira; Yatomi, Yutaka; Satoh, Yoshioki; Nakamura, Yuji; Hashimoto, Keitaro
2003-06-01
Given the limited information, physiological roles of Rho-kinase in the cardiac conduction system and ventricular repolarization process were assessed in comparison with those in the coronary vascular tone. A specific Rho-kinase inhibitor Y-27632 was administered to the nutrient coronary artery of the canine isolated, blood-perfused atrioventricular node preparation under the monitoring of the ventricular monophasic action potentials. Administration of Y-27632 moderately suppressed the atrioventricular nodal conduction, slightly but significantly accelerated the repolarization process, and potently increased the coronary blood flow, whereas it hardly affected the intraventricular conduction. The estimated concentrations of Y-27632 causing the currently observed effects were enough to inhibit Rho-kinase. These results suggest that constitutional Rho-kinase functions to moderately facilitate the atrioventricular nodal conduction, slightly delay ventricular repolarization process, and significantly increase the coronary vascular tone.
Ylitalo, Pekka; Jokinen, Eero; Lauerma, Kirsi; Holmström, Miia; Pitkänen-Argillander, Olli M
2018-02-01
Right ventricular dysfunction in patients with tetralogy of Fallot and significant pulmonary regurgitation may lead to systolic dysfunction of the left ventricle due to altered ventricular interaction. We were interested in determining whether chronic pulmonary regurgitation affects the preload of the left ventricle. In addition, we wanted to study whether severe chronic pulmonary regurgitation would alter the preload of the left ventricle when compared with patients having preserved pulmonary valve annulus. The study group comprised 38 patients with tetralogy of Fallot who underwent surgical repair between 1990 and 2003. Transannular patching was required in 21 patients to reconstruct the right ventricular outflow tract. Altogether, 48 age- and gender-matched healthy volunteers were recruited. Cardiac MRI was performed on all study patients to assess the atrial and ventricular volumes and function. Severe pulmonary regurgitation (>30 ml/m2) was present in 13 patients, of whom 11 had a transannular patch, but only two had a preserved pulmonary valve annulus. The ventricular preload volumes from both atria were significantly reduced in patients with severe pulmonary regurgitation, and left ventricular stroke volumes (44.1±4.7 versus 58.9±10.7 ml/m2; p<0.0001) were smaller compared with that in patients with pulmonary regurgitation <30 ml/m2 or in controls. In patients with tetralogy of Fallot, severe pulmonary regurgitation has a significant effect on volume flow through the left atrium. Reduction in left ventricular preload volume may be an additional factor contributing to left ventricular dysfunction.
Partitioned fluid-solid coupling for cardiovascular blood flow: left-ventricular fluid mechanics.
Krittian, Sebastian; Janoske, Uwe; Oertel, Herbert; Böhlke, Thomas
2010-04-01
We present a 3D code-coupling approach which has been specialized towards cardiovascular blood flow. For the first time, the prescribed geometry movement of the cardiovascular flow model KaHMo (Karlsruhe Heart Model) has been replaced by a myocardial composite model. Deformation is driven by fluid forces and myocardial response, i.e., both its contractile and constitutive behavior. Whereas the arbitrary Lagrangian-Eulerian formulation (ALE) of the Navier-Stokes equations is discretized by finite volumes (FVM), the solid mechanical finite elasticity equations are discretized by a finite element (FEM) approach. Taking advantage of specialized numerical solution strategies for non-matching fluid and solid domain meshes, an iterative data-exchange guarantees the interface equilibrium of the underlying governing equations. The focus of this work is on left-ventricular fluid-structure interaction based on patient-specific magnetic resonance imaging datasets. Multi-physical phenomena are described by temporal visualization and characteristic FSI numbers. The results gained show flow patterns that are in good agreement with previous observations. A deeper understanding of cavity deformation, blood flow, and their vital interaction can help to improve surgical treatment and clinical therapy planning.
An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).
Yamazaki, K; Litwak, P; Tagusari, O; Mori, T; Kono, K; Kameneva, M; Watach, M; Gordon, L; Miyagishima, M; Tomioka, J; Umezu, M; Outa, E; Antaki, J F; Kormos, R L; Koyanagi, H; Griffith, B P
1998-06-01
A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).
Jung, Mette Holme; Hansen, Peter Bo; Sander, Kaare; Olsen, Peter Skov; Rossing, Kasper; Boesgaard, Soeren; Russell, Stuart D; Gustafsson, Finn
2014-04-01
Continuous-flow left ventricular assist device (CF-LVAD) implantation is associated with improved quality of life, but the effect on exercise capacity is less well documented. It is uncertain whether a fixed CF-LVAD pump speed, which allows for sufficient circulatory support at rest, remains adequate during exercise. The aim of this study was to evaluate the effects of fixed versus incremental pump speed on peak oxygen uptake (peak VO2) during a maximal exercise test. In CF-LVAD (HeartMate II) patients exercise testing measuring peak oxygen uptake (VO2) was performed on an ergometer bike twice in one day: once with fixed pump speed (testfix) and once with incremental pump speed (testinc). The order of testfix and testinc in each patient was determined by randomization. During testinc pump speed was increased from the baseline value by 400 rpm/2 min. Fourteen patients (aged 23–69 years) were included with a mean support duration of 465±483 days. Baseline CF-LVAD speed was 9357±238 rpm and during testinc speed was increased by a mean of 1486±775 rpm. Mean peak VO2 was significantly higher in testinc compared with testfix (15.4±5.9 mL/kg/min vs. 14.1±6.3 mL/kg/min; P=0.012), corresponding to a 9.2% increase. All exercise tests (n=28) were adequately performed with RER>1. Increasing pump speed during exercise augments peak VO2 in patients supported with CF-LVADs. An automatic speed-change function in future generations of CF-LVADs might improve functional capacity. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.
Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad
2017-06-01
Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad
2016-01-01
Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072
Trachtenberg, Barry H; Cordero-Reyes, Andrea M; Aldeiri, Molham; Alvarez, Paulino; Bhimaraj, Arvind; Ashrith, Guha; Elias, Barbara; Suarez, Erik E; Bruckner, Brian; Loebe, Matthias; Harris, Richard L; Zhang, J Yi; Torre-Amione, Guillermo; Estep, Jerry D
2015-02-01
Common adverse events in patients supported with Continuous-flow left ventricular assist devices (CF-LVAD) include infections and cerebrovascular accidents (CVA). Some studies have suggested a possible association between blood stream infection (BSI) and CVA. Medical records of patients who received Heartmate II (HMII) CF-LVADs in 2008-2012 at a single center were reviewed. CVA was categorized as either hemorrhagic (HCVA) or ischemic (ICVA). BSI was divided into persistent (pBSI) and nonpersistent (non-pBSI). pBSI was defined as BSI with the same organism on repeated blood culture >72 hours from initial blood culture despite antibiotics. Univariate and multivariate analyses were performed to determine predictors. A total of 149 patients had HMII implanted; 76% were male, and the overall mean age was 55.4 ± 13 years. There were a total of 19 (13%) patients who had CVA (7 HCVA and 12 ICVA) at a median of 295 days (range 5-1,096 days) after implantation. There were a total of 28 (19%) patients with pBSI and 17 (11%) patients with non-pBSI. Patients with pBSI had a trend toward greater BMI (31 kg/m(2) vs 27 kg/m(2); P = .09), and longer duration of support (1,019 d vs 371 d; P < .001) compared with those with non-pBSI. Persistent BSI was associated with an increased risk of mortality and with all-cause CVA on multivariate analysis (odds ratio [OR] 5.97; P = .003) as well as persistent Pseudomonas aeruginosa infection (OR 4.54; P = .048). Persistent BSI is not uncommon in patients supported by CF-LVAD and is highly associated with all-cause CVA and increased all-cause mortality. Copyright © 2015 Elsevier Inc. All rights reserved.
Tomizawa, Yutaka; Tanaka, Akiko; Kitahara, Hiroto; Sakuraba, Atsushi; Uriel, Nir; Jeevanandam, Valluvan; Ota, Takeyoshi
2018-06-01
Large scale data on preoperative risk stratification for gastrointestinal bleeding (GIB) following continuous-flow left ventricular assist device (CF-LVAD) implantation are scarce. To identify independent predictors for GIB following CF-LVAD implantation. We conducted a retrospective cohort study of consecutive 243 patients who underwent CF-LVAD implantation (HeartMateII) from January 2009 to March 2015 at the University of Chicago Medical Center. GIB was defined as the presence of overt bleeding or occult GIB with ≥ 2 g/dl drop in hemoglobin (Hgb) from recorded baseline values and hemoccult-positive stool. The preoperative and postoperative data were reviewed. Within a median follow-up duration of 408 (IQR 113-954) days, 83 (34%) patients developed GIB after a median of 149 (IQR 27-615) days after implantation of CF-LVAD. There were no significant differences between the groups of GIB and non-GIB with respect to preoperative demographics and comorbidity except for ethnicity. The source of bleeding was identified in 39 (47%) patients and arteriovenous malformation or submucosal streaming vessel was the most frequent cause of bleeding (18/39, 46%). Multivariate-adjusted analysis demonstrated preoperative central venous pressure (CVP) ≥ 18 mmHg (HR 3.56; 95% CI 1.16-10.9; p = 0.026), mean pulmonary artery pressure (mPA) ≥ 36 mmHg (HR 4.14; 95% CI 1.35-12.7; p = 0.013), and the presence of moderate/severe tricuspid valve disease (HR 1.01; 95% CI 1.01-3.86; p = 0.046) were associated with the risk of GIB. In this study, preoperative right-sided cardiac congestion (i.e., increased CVP, mPA and the presence of moderate/severe tricuspid valve disease) was associated with GIB in patients with CF-LVAD.
Sandoval, Elena; Singh, Steve K; Carillo, Julius A; Baldwin, Andrew C W; Ono, Masahiro; Anand, Jatin; Frazier, O H; Mallidi, Hari R
2017-10-01
Mitral regurgitation (MR) is common in patients with end-stage heart failure. We assessed the effect of performing concomitant mitral valve repair during continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with severe preoperative MR. We performed a single-centre, retrospective review of all patients who underwent CF-LVAD implantation between December 1999 and December 2013 (n = 469). Patients with severe preoperative MR (n = 78) were identified and then stratified according to whether they underwent concomitant valve repair. Univariate and survival analyses were performed, and multivariable regression was used to determine predictors of survival. Of the 78 patients with severe MR, 21 underwent valve repair at the time of CF-LVAD implantation (repair group) and 57 did not (non-repair group). A comparison of the 2 groups showed significant differences between groups: INTERMACS I 16.985 vs 9.52%, (P = 0.039), cardiopulmonary bypass time 82.09 vs 109.4 min (P = 0.0042) and the use of HeartMate II 63.16 vs 100% (P = 0.001). Survival analysis suggested trends towards improved survival and a lower incidence of heart failure-related readmissions in the repair group. Multivariable regression analysis showed no significant independent predictors of survival (mitral valve repair: odds ratio 0.4, 95% confidence interval 0.8-1.5; P = 0.2). Despite the lack of statistical significance, trends towards improved survival and a lower incidence of heart failure events suggest that mitral valve repair may be beneficial in patients undergoing CF-LVAD implantation. Given the known relationship between severe MR and mortality, further study is encouraged to confirm the value of mitral valve repair in these patients. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Kato, Atsuko; Drolet, Christian; Yoo, Shi-Joon; Redington, Andrew N; Grosse-Wortmann, Lars
2016-06-07
The left pulmonary artery (LPA) contributes more than the right (RPA) to total pulmonary regurgitation (PR) in patients after tetralogy of Fallot (TOF) repair, but the mechanism of this difference is not well understood. This study aimed to analyze the interplay between heart and lung size, mediastinal geometry, and differential PR. Forty-eight Cardiovascular Magnetic Resonance (CMR) studies in patients after TOF repair were analyzed. In addition to the routine blood flow and ventricular volume quantification cardiac angle between the thoracic anterior-posterior line and the interventricular septum, right and left lung areas as well as right and left hemithorax areas were measured on an axial image. Statistical analysis was performed to compare flow parameters between RPA and LPA and to assess correlation among right ventricular volume, pulmonary blood flow parameters and lung area. There was no difference between LPA and RPA diameters. The LPA showed significantly less total forward flow (2.49 ± 0.87 L/min/m(2) vs 2.86 ± 0.89 L/min/m(2); p = 0.02), smaller net forward flow (1.40 ± 0.51 vs 1.89 ± 0.60 mL/min/m(2); p = <0.001), and greater regurgitant fraction (RF) (34 ± 10 % vs 43 ± 12 %; p = 0.001) than the RPA. There was no difference in regurgitant flow volume between RPA and LPA (p = 0.29). Indexed right ventricular end-diastolic volume (RVEDVi) correlated with LPA RF (R = 0.48, p < 0.001), but not with RPA RF (p = 0.09). Larger RVEDVi correlated with a more leftward cardiac axis (R = 0.46, p < 0.001) and with smaller left lung area (R = -0.58, p < 0.001). LPA RF, but not RPA RF, correlated inversely with left lung area (R = -0.34, p = 0.02). The follow-up CMRs in 20 patients showed a correlation of the rate of RV enlargement with the rates of LPA RF worsening (R = 0.50, p = 0.03), and of increasing left lung compression (R = -0.55, p = 0.012). An enlarged and levorotated heart is associated with left lung compression and impaired flow into the left lung.
PULMONARY CIRCULATION AT EXERCISE
NAEIJE, R; CHESLER, N
2012-01-01
The pulmonary circulation is a high flow and low pressure circuit, with an average resistance of 1 mmHg.min.L−1 in young adults, increasing to 2.5 mmHg.min.L−1 over 4–6 decades of life. Pulmonary vascular mechanics at exercise are best described by distensible models. Exercise does not appear to affect the time constant of the pulmonary circulation or the longitudinal distribution of resistances. Very high flows are associated with high capillary pressures, up to a 20–25 mmHg threshold associated with interstitial lung edema and altered ventilation/perfusion relationships. Pulmonary artery pressures of 40–50 mmHg, which can be achieved at maximal exercise, may correspond to the extreme of tolerable right ventricular afterload. Distension of capillaries that decrease resistance may be of adaptative value during exercise, but this is limited by hypoxemia from altered diffusion/perfusion relationships. Exercise in hypoxia is associated with higher pulmonary vascular pressures and lower maximal cardiac output, with increased likelihood of right ventricular function limitation and altered gas exchange by interstitial lung edema. Pharmacological interventions aimed at the reduction of pulmonary vascular tone have little effect on pulmonary vascular pressure-flow relationships in normoxia, but may decrease resistance in hypoxia, unloading the right ventricle and thereby improving exercise capacity. Exercise in patients with pulmonary hypertension is associated with sharp increases in pulmonary artery pressure and a right ventricular limitation of aerobic capacity. Exercise stress testing to determine multipoint pulmonary vascular pressures-flow relationships may uncover early stage pulmonary vascular disease. PMID:23105961
Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike
2018-02-24
To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.
NASA Astrophysics Data System (ADS)
Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.
2017-11-01
In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.
Verma, Sean; Bassily, Emmanuel; Leighton, Shane; Mhaskar, Rahul; Sunjic, Igor; Martin, Angel; Rihana, Nancy; Jarmi, Tambi; Bassil, Claude
2017-01-01
Background Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. Methods In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer’s exact at the significance level of 0.05. Results Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). Conclusion Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period. PMID:28611860
NASA Technical Reports Server (NTRS)
Nakatani, S.; Thomas, J. D.; Vandervoort, P. M.; Zhou, J.; Greenberg, N. L.; Savage, R. M.; McCarthy, P. M.
1997-01-01
OBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.
Srimachai, Sirintorn; Devaux, Sylvie; Demougeot, Celine; Kumphune, Sarawut; Ullrich, Nina D; Niggli, Ernst; Ingkaninan, Kornkanok; Kamkaew, Natakorn; Scholfield, C Norman; Tapechum, Sompol; Chootip, Krongkarn
2017-02-20
This study explored Bacopa monnieri, a medicinal Ayurvedic herb, as a cardioprotectant against ischemia/reperfusion injury using cardiac function and coronary flow as end-points. In normal isolated rat hearts, coronary flow, left ventricular developed pressure, heart rate, and functional recovery were measured using the Langendorff preparation. Hearts were perfused with either (i) Krebs-Henseleit (normal) solution, (control), or with 30, 100 μg/ml B. monnieri ethanolic extract (30 min), or (ii) with normal solution or extract for 10 min preceding no-perfusion ischemia (30 min) followed by reperfusion (30 min) with normal solution. Infarct volumes were measured by triphenyltetrazolium staining. L-type Ca 2+ -currents (I Ca, L ) were measured by whole-cell patching in HL-1 cells, a mouse atrial cardiomyocyte cell line. Cytotoxicity of B. monnieri was assessed in rat isolated ventricular myocytes by trypan blue exclusion. In normally perfused hearts, B. monnieri increased coronary flow by 63 ± 13% (30 μg/ml) and 216 ± 21% (100 μg/ml), compared to control (5 ± 3%) (n = 8-10, p < 0.001). B. monnieri treatment preceding ischemia/reperfusion improved left ventricular developed pressure by 84 ± 10% (30 μg/ml), 82 ± 10% (100 μg/ml) and 52 ± 6% (control) compared to pre- ischemia/reperfusion. Similarly, functional recovery showed a sustained increase. Moreover, B. monnieri (100 μg/ml) reduced the percentage of infarct size from 51 ± 2% (control) to 25 ± 2% (n = 6-8, p < 0.0001). B. monnieri (100 μg/ml) reduced I Ca, L by 63 ± 4% in HL-1 cells. Ventricular myocyte survival decreased at higher concentrations (50-1000 μg/ml) B. monnieri. B. monnieri improves myocardial function following ischemia/reperfusion injury through recovery of coronary blood flow, contractile force and decrease in infarct size. Thus this may lead to a novel cardioprotectant strategy.
Schönberger, Markus; Deutsch, Steven; Manning, Keefe B.
2012-01-01
Ventricular assist devices are a commonly used heart failure therapy for adult patients as bridge-to-transplant or bridge-to-recovery tool. The application of adult ventricular assist devices in pediatric patients has led to increased thrombotic events. Therefore, we have been developing a pediatric ventricular assist device, the Penn State 12 cc PVAD. It is designed for patients with a body weight of 5 to 15 kg and has a stroke volume of 12 cc. Clot formation is the major concern. It is correlated to the coagulability of blood, the blood contacting materials and the fluid dynamics within the system. The intent is for the PVAD to be a long term therapy. Therefore, the system may be oriented in different positions according to the patient’s behavior. This study evaluates for the first time the impact of position on the flow patterns within the Penn State 12 cc PVAD, which may help to improve the PVAD design concerning chamber and ports geometries. The fluid dynamics are visualized by particle image velocimetry. The evaluation is based on inlet jet behavior and calculated wall shear rates. Vertical and horizontal model orientations are compared, both with a beat rate of 75, outlet pressures of 90/60 mmHg and a flow rate of 1.3 l/min. The results show a significant change of the inlet jet behavior and the development of a rotational flow pattern. Vertically, the inlet jet is strong along the wall. It initiates a rotational flow pattern with a wandering axis of rotation. In contrast, the horizontal model orientation results show a weaker inlet jet along the wall with a nearly constant center of rotation location, which can be correlated to a higher risk of thrombotic events. In addition high speed videography illustrates differences in the diaphragm motion during diastole. Diaphragm opening trajectories measurements determine no significant impact of the density of the blood analog fluids. Hence, the results correlate to human blood. PMID:22929894
Järverud, K; Ollmar, S; Brodin, L A
2002-09-01
Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.
Effect of free fatty acids on myocardial function and metabolism in the ischemic dog heart
Kjekshus, John K.; Mjøs, Ole D.
1972-01-01
Since elevation of plasma concentrations of free fatty acids (FFA) increases myocardial oxygen consumption without influencing mechanical performance in normal hearts, it was the purpose of this study to determine whether FFA would modify mechanical performance at limited oxygen supply. Left coronary blood flow was reduced by gradual clamping of a shunt from the left carotid artery until moderate ventricular dilatation supervened. Left ventricular systolic pressure (LVSP), its maximal rate of rise (dP/dt) and stroke volume (SV) were unchanged or slightly reduced. The ischemia resulted in a decrease in myocardial oxygen consumption (MVO2) from 9.7±1.1 ml/min to 7.9±0.8 ml/min, and myocardial lactate uptake was reduced or reversed to excretion. Increasing the plasma concentrations of FFA from 359±47 μEq/1 to 3688±520 μEq/1 by intravenous infusion of a triglyceride emulsion and heparin resulted in further ventricular dilatation, accompanied by increased excretion of lactate. The ventricular decompensation and enhancement of anaerobic myocardial metabolism associated with increased uptake of FFA was not related to changes in coronary flow, MVO2, or LVSP. dP/dt and SV were virtually unchanged. Intravenous infusion of glucose/insulin, which lowered plasma concentrations of FFA, reversed ventricular dilatation and lactate excretion. The data support the hypothesis that high concentrations of FFA play a significant role in increasing myocardial oxygen requirement and thereby promote depression of contractility of the hypoxic heart in experimental animals. Images PMID:5032525
Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.
Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo
2006-07-01
Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.
Zuchinali, Priccila; Souza, Gabriela C; Pimentel, Maurício; Chemello, Diego; Zimerman, André; Giaretta, Vanessa; Salamoni, Joyce; Fracasso, Bianca; Zimerman, Leandro I; Rohde, Luis E
2016-12-01
The presumed proarrhythmic action of caffeine is controversial. Few studies have assessed the effect of high doses of caffeine in patients with heart failure due to left ventricular systolic dysfunction at high risk for ventricular arrhythmias. To compare the effect of high-dose caffeine or placebo on the frequency of supraventricular and ventricular arrhythmias, both at rest and during a symptom-limited exercise test. Double-blinded randomized clinical trial with a crossover design conducted at the heart failure and cardiac transplant clinic of a tertiary-care university hospital. The trial included patients with chronic heart failure with moderate-to-severe systolic dysfunction (left ventricular ejection fraction <45%) and New York Heart Association functional class I to III between March 5, 2013, and October 2, 2015. Caffeine (100 mg) or lactose capsules, in addition to 5 doses of 100 mL decaffeinated coffee at 1-hour intervals, for a total of 500 mg of caffeine or placebo during a 5-hour protocol. After a 1-week washout period, the protocol was repeated. Number and percentage of ventricular and supraventricular premature beats assessed by continuous electrocardiographic monitoring. We enrolled 51 patients (37 [74%] male; mean [SD] age, 60.6 [10.9] years) with predominantly moderate-to-severe left ventricular systolic dysfunction (mean [SD] left ventricular ejection fraction, 29% [7%]); 31 [61%] had an implantable cardioverter-defibrillator device. No significant differences between the caffeine and placebo groups were observed in the number of ventricular (185 vs 239 beats, respectively; P = .47) and supraventricular premature beats (6 vs 6 beats, respectively; P = .44), as well as in couplets, bigeminal cycles, or nonsustained tachycardia during continuous electrocardiographic monitoring. Exercise test-derived variables, such as ventricular and supraventricular premature beats, duration of exercise, estimated peak oxygen consumption, and heart rate, were not influenced by caffeine ingestion. We observed no increases in ventricular premature beats (91 vs 223 vs 207 beats, respectively) in patients with higher levels of plasma caffeine concentration compared with lower plasma levels (P = .91) or with the placebo group (P = .74). Acute ingestion of high doses of caffeine did not induce arrhythmias in patients with systolic heart failure and at high risk for ventricular arrhythmias. clinicaltrials.gov Identifier: NCT02045992.
Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele
2018-04-13
To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P < .05). Retrograde perfusion from the level of the conduit insertion in the descending thoracic aorta toward the aortic arch accounted for 6.9% of total cardiac output and 11% of total conduit flow. We did not observe any significant reduction in left ventricular stroke volume at postoperative evaluation compared with preoperative evaluation (P = .435). No differences were observed between preoperative and postoperative CBF at the gray matter, dorsal default-mode network, and sensorimotor levels (P = .394). After AVB surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Cho, In-Jeong; Shim, Chi Young; Moon, Sun-Ha; Lee, Hyun-Jin; Hong, Geu-Ru; Chung, Namsik; Ha, Jong-Won
2017-05-01
The shape and duration of left ventricular outflow tract (LVOT) flow has not been applied to assess the central haemodynamics, although LVOT flow is confronted with afterload of arterial system during systole. The aim of this study was to evaluate whether the LVOT flow parameters are related with central systolic blood pressure (BP) and arterial compliance at rest and as well as during exercise. We studied 258 subjects (175 females, age 61 ± 11 years) with normal left ventricular (LV) systolic function who underwent supine bicycle stress echocardiography and arterial tonometry simultaneously at rest and at peak exercise. Deceleration time (DT) of LVOT flow and RR interval were measured and deceleration time corrected for heart rate (DTc) was calculated. Peripheral and central haemodynamic parameters including systolic and diastolic BP, and augmentation index at a heart rate of 75 (AIx@75) were assessed using radial artery tonometry. Carotid femoral pulse wave velocity (PWV) was measured. Deceleration time corrected for heart rate was independently associated with central systolic BP and AIx@75 at rest (P < 0.001 and 0.006). Similarly, it also showed significant independent correlations with central systolic BP and AIx@75 during peak exercise (P = 0.006 and P = 0.021). In addition, DTc which measured both at rest and at peak exercise demonstrated significant positive correlations with PWV, suggesting association of prolonged DTc with arterial stiffening (P = 0.023 and P = 0.005). Prolongation of LVOT flow DTc represents raised central systolic BP and increased arterial stiffness not only at rest but also during exercise. Therefore, central aortic pressures and arterial stiffness influence the DT of LVOT flow at rest as well as during exercise in individuals with normal LV systolic function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Tan, Yong-Qiang Benjamin; Ngiam, Jinghao Nicholas; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong
2016-10-15
Paradoxical low-flow aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) has only been described in severe AS. Controversy surrounds prognosis and management but no studies have reported this phenomenon in mild or moderate AS. We investigated the prevalence of flow and gradient patterns in this population, characterising their clinical and echocardiographic profile. Consecutive subjects (n=1362) with isolated AS: mild (n=462, aortic valve area≥1.5cm(2), 2.5m/s
NASA Technical Reports Server (NTRS)
Pasquet, A.; Garcia, M. J.; Thomas, J. D.
1999-01-01
Over the past decade, Doppler echocardiography has become a well-established tool for the diagnosis of left ventricular diastolic dysfunction. Unfortunately, in many clinical situations traditional Doppler indices of transmittal and pulmonary venous flow are inconclusive, primarily due to their dependence on left atrial pressure. Recently, new Doppler indices that are much less dependent on preload have been developed, based on intraventricular flow propagation and intrinsic myocardial velocity. These methodologies provide direct assessment of ventricular relaxation and the small intraventricular pressure gradients essential to efficient filling of the ventricle. We review in this article the theoretical and experiment background of these new echo techniques as well as how they can be implemented in routine clinical practice.
Gehlen, H; Kroker, K; Deegen, E; Stadler, P
2004-03-01
30 warmblood horses were examined before and after sedation with 20 micrograms/kg BW detomidine, to determine changes of cardiac function parameters, using B-mode, M-mode and Doppler echocardiography. 15 horses showed a heart murmur, but no clinical signs of cardiac heart failure, 15 horses had neither a heart murmur nor other signs of cardiac disease. After sedation with detomidine we could recognise a significant increase of end-diastolic left atrium diameter, an increase of end-systolic left ventricular diameter and aortic root diameter. The end-systolic thickness of papillary muscle and interventricular septum showed a decrease. Fractional shortening and amplitude of left ventricular wall motion was decreased after sedation. The mitral valve echogram revealed a presystolic valve closure and an inflection in the Ac slope (B-notch) in xy horses before sedation. Both increased after sedation with detomidine. Doppler echocardiography showed a decrease of blood flow velocity and velocity time integral (VTI) in the left and right ventricular outflow tract after sedation. Regurgitant flow signals were intensified following sedation in xy horses, especially at the mitral valve.
2001-12-01
instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to...isoflurane in 100% oxy- gen) prior to insertion of the high -fidelity pressure micromanome- ters during cardiac fluoroscopy. Once the micromanometer trans...and allowed to fully recover from the isoflurane seda- tion for a period of 60 min, during which blood pressure and aortic flow were monitored to ensure
Implantation of a HeartMate II left ventricular assist device via left thoracotomy.
Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J
2012-11-01
Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Raman, Subha V.; Sahu, Anurag; Merchant, Ali Z.; Louis, Louis B.; Firstenberg, Michael S.; Sun, Benjamin
2009-01-01
Background Left ventricular assist devices (LVADs) provide a bridge to recovery or heart transplantation, but require serial assessment. Echocardiographic approaches may be limited by device artifact and acoustic window. Cardiovascular computed tomography (CCT) provides noninvasive imaging of LVADs, yet no study has evaluated CCT’s impact on clinical care. We evaluated the diagnostic findings and clinical impact of CCT for noninvasive assessment of patients with LVADs. Methods CCT examinations performed between 2005 and 2008 in patients with LVADs were identified. Acquisitions were completed on the identical 64 detector-row scanner with intravenous contrast administration; electrocardiographic gating was used in patients with pulsatile devices, while peripheral pulse gating was used in patients with continuous-flow devices. Comparison was made between CCT results and 30-day outcomes, including echocardiographic and intraoperative findings. Results Thirty-two CCT examinations from 28 patients were reviewed. Indications included evaluation of low cardiac output symptoms, assessment of cannula position, low flow reading on the LVAD, and surgical planning. CCT identified critical findings in 6 patients including thrombosis and inlet cannula malposition, all confirmed intraoperatively; one case of intra-LVAD thrombus was missed by CCT. Using intraoperative findings as the gold standard, CCT’s sensitivity was 85% and specificity was 100%. Echocardiographic LVAD evaluation did not correlate with findings on CCT (kappa = −0.29, 95% CI −0.73−0.13). Conclusions This preliminary observational cohort study indicates that noninvasive imaging using CCT of LVADs is feasible and accurate. CCT warrants consideration in the initial evaluation of symptomatic patients with LVADs. PMID:19782594
Rothfuss, M A; Pascht, U; Kissling, G
2001-01-01
The effect of long-term application of Crataegus oxyacantha on ischemia and reperfusion induced arrhythmias was investigated in Wistar rats on the heart in situ and on Langendorff preparations. Seventeen rats were fed for 8 weeks with 0.5 g/kg b.w. Crataegus extract per day, standardised to 2.2% flavonoids. Twenty age-matched untreated rats served as controls. In the hearts in situ as well as in the Langendorff preparations the left anterior descending coronary artery (LAD) was ligated for 20 min and subsequently reperfused for 30 min. ECG was continuously recorded and the time spent between start of ischemia and onset of arrhythmias was measured. In addition, during ischemia and reperfusion the number of ventricular premature beats and bigemini and the duration of salvos and ventricular flutter and fibrillation were determined. The ischemic area was evaluated in all experiments and coronary flow was measured in Langendorff preparations. In the present experiments, no cardioprotective effects of Crataegus oxyacantha could be detected, neither in the heart in situ nor in the Langendorff preparations. Although the ischemic areas were identical, arrhythmias occurred even earlier in the Crataegus collectives than in the controls. Also the number and duration of ischemia and reperfusion induced arrhythmias tended to occur longer and more frequently in the Crataegus collectives, whilst coronary flow remained unchanged. The phenomenon that Crataegus rather aggravates than prevents arrhythmias may be reduced to a Crataegus induced increase in intracellular Ca(2+)-concentration proven true for the positive inotropic effects of Crataegus.
Zhang, Xiaohai; Mirocha, James; Aintablian, Tamar; Dimbil, Sadia; Moriguchi, Jaime; Arabia, Francisco; Kobashigawa, Jon A; Reinsmoen, Nancy
2018-02-01
Increased levels of angiotensin II type 1 receptor (AT 1 R) antibody have been shown to be associated with allograft rejection. This study aims to determine the rate of development of antibody to AT 1 R after mechanical circulatory support device (MCS) implantation, and if the development of strong binding AT 1 R antibodies is associated with survival. Eighty-eight patients who had one MCS implantation were accessed based on serum availability. Mechanical circulatory support devices in this cohort included pneumatic bilateral paracorporeal ventricular assist device, continuous flow left ventricular assist device, and total artificial heart. Of 88 patients, seven patients had AT 1 R antibodies ≥40 U/mL preimplantation. For 81 patients who had AT 1 R antibodies <40 U/mL, the median value was 8 U/mL. Of these 81 patients, AT 1 R antibody levels in 55 (68%) patients reached the saturated concentration (≥40 U/mL) postimplantation (P < .0001), with the highest percentage of patients with the saturated level of AT 1 R antibody observed in the pneumatic bilateral paracorporeal ventricular assist device group. Compared to patients without the saturated level of AT 1 R antibodies, patients with the saturated AT 1 R antibody level had lower 18-month survival (P = .040). Mechanical circulatory support devices implantation significantly increases AT 1 R antibody levels. The saturated level of AT 1 R antibodies is associated with lower patient survival postimplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Grupper, Avishay; Zhao, Yanjun M; Sajgalik, Pavol; Joyce, Lyle D; Park, Soon J; Pereira, Naveen L; Stulak, John M; Burnett, John C; Edwards, Brooks S; Daly, Richard C; Kushwaha, Sudhir S; Schirger, John A
2016-06-01
Neurohormonal blockade drug therapy (NHBDT) is the cornerstone therapy in heart failure (HF) management for promoting reverse cardiac remodeling and improving outcomes. It's utility in left ventricular assist device (LVAD) supported patients remains undefined. Sixty-four patients who received continuous flow LVAD at our institution were retrospectively reviewed and divided into 2 groups: no-NHBDT group (n = 33) received LVAD support only and NHBDT group (n = 31) received concurrent NHBDT based on the clinical judgment of the attending physicians. Cardiac remodeling (echocardiographic parameters and biomarkers) and clinical outcome (functional status, HF-related hospital readmissions, and mortality) data were collected. A statistically significant increase in ejection fraction, decrease in LV end-diastolic diameter index and LV mass index, and a sustained reduction in N-terminal pro B-type natriuretic peptide (NTproBNP) were observed in the NHBDT group at 6 months after LVAD implant (p <0.05). NHBDT-treated patients experienced significantly greater improvement in New York Heart Association functional classification and 6-minute-walk distance throughout the study. The combined end point of cardiovascular death or HF hospitalization was significantly reduced in patients receiving NHBDT (p = 0.013) associated primarily with a 12.1% absolute reduction in HF-related hospitalizations (p = 0.046). In conclusion, NHBDT in LVAD-supported patients is associated with a significant reversal in adverse cardiac remodeling and a reduction in morbidity and mortality compared with LVAD support alone. Copyright © 2016 Elsevier Inc. All rights reserved.
Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C. M.; Segers, Patrick; Schaeffter, Tobias
2017-01-01
Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R2 = 0.94) but underestimated wave reflection (correlation: 0.75, R2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. PMID:28576835
Gaddum, Nicholas; Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C M; Segers, Patrick; Schaeffter, Tobias
2017-09-01
Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R 2 = 0.94) but underestimated wave reflection (correlation: 0.75, R 2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. Copyright © 2017 the American Physiological Society.
Lindholm, E E; Aune, E; Frøland, G; Kirkebøen, K A; Otterstad, J E
2014-06-01
The aim of this study was to define pre-operative echocardiographic data and explore if postoperative indices of cardiac function after open abdominal aortic surgery were affected by the anaesthetic regimen. We hypothesised that volatile anaesthesia would improve indices of cardiac function compared with total intravenous anaesthesia. Transthoracic echocardiography was performed pre-operatively in 78 patients randomly assigned to volatile anaesthesia and 76 to total intravenous anaesthesia, and compared with postoperative data. Pre-operatively, 16 patients (10%) had left ventricular ejection fraction < 46%. In 138 patients with normal left ventricular ejection fraction, 5/8 (62%) with left ventricular dilatation and 41/130 (33%) without left ventricular dilatation had evidence of left ventricular diastolic dysfunction (p < 0.001). Compared with pre-operative findings, significant increases in left ventricular end-diastolic volume, left atrial maximal volume, cardiac output, velocity of early mitral flow and early myocardial relaxation occurred postoperatively (all p < 0.001). The ratio of the velocity of early mitral flow to early myocardial relaxation remained unchanged. There were no significant differences in postoperative echocardiographic findings between patients anaesthetised with volatile anaesthesia or total intravenous anaesthesia. Patients had an iatrogenic surplus of approximately 4.1 l of fluid volume by the first postoperative day. N-terminal prohormone of brain natriuretic peptide increased on the first postoperative day (p < 0.001) and remained elevated after 30 days (p < 0.001) in both groups. Although postoperative echocardiographic alterations were most likely to be related to increased preload due to a substantial iatrogenic surplus of fluid, a component of peri-operative myocardial ischaemia cannot be excluded. Our hypothesis that volatile anaesthesia improved indices of cardiac function compared with total intravenous anaesthesia could not be verified. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Magalski, Anthony; Adamson, Philip; Gadler, Frederick; Böehm, Michael; Steinhaus, David; Reynolds, Dwight; Vlach, Kathryn; Linde, Cecilia; Cremers, Bodo; Sparks, Brandon; Bennett, Tom
2002-04-01
We describe the performance of an implantable hemodynamic monitor (IHM) that allows continuous recording of heart rate, patient activity levels, and right ventricular systolic, right ventricular diastolic, and estimated pulmonary artery diastolic pressures. Pressure parameters derived from the implantable monitor were correlated to measurements made with a balloon-tipped catheter to establish accuracy and reproducibility over time in patients with chronic heart failure (CHF). IHM devices were implanted in 32 patients with CHF (left ventricular ejection fraction, 29% +/- 11%; range, 14%-62%) and were tested with right heart catheterization at implantation and 3, 6, and 12 months later. Hemodynamic variables were digitally recorded simultaneously from the IHM and catheter. Values were recorded during supine rest, peak response of Valsalva maneuver, sitting, peak of a 2-stage (25-50 W) bicycle exercise test, and final rest period. The median of 21 paired beat-to-beat cardiac cycles was analyzed for each intervention. A total of 217 paired data values from all maneuvers were analyzed for 32 patients at implantation and 129 paired data values for 20 patients at 1 year. The IHM and catheter values were not different at baseline or at 1 year (P >.05). Combining all interventions, correlation coefficients were 0.96 and 0.94 for right ventricular systolic pressure, 0.96 and 0.83 for right ventricular diastolic pressure, and 0.87 and 0.87 for estimated pulmonary artery diastolic pressure at implantation and 1 year, respectively. The IHM and a standard reference pressure system recorded comparable right heart pressure values in patients with CHF. This implantable pressure transducer is accurate over time and provides a means to precisely monitor the hemodynamic condition of patients with CHF in a continuous fashion.
Haemodynamic and energetic properties of stunned myocardium in rabbit hearts.
Schipke, J. D.; Korbmacher, B.; Dorszewski, A.; Selcan, G.; Sunderdiek, U.; Arnold, G.
1996-01-01
OBJECTIVE--To amplify the description of myocardial stunning. DESIGN--Control versus 30 min after a 20 min no flow ischaemia. EXPERIMENTAL ANIMALS--15 isolated rabbit hearts perfused with erythrocyte suspension. MAIN OUTCOME MEASURES--Left ventricular systolic function in terms of aortic flow, peak systolic pressure (LVPmax), dP/dtmax, and the end systolic pressure-volume relation (ESPVR); early relaxation from dP/dtmin and rate of left ventricular pressure decay (tau). Passive properties: ventricular and myocardial stiffness. Coronary resistance from coronary blood flow and perfusion pressure. Total myocardial oxygen consumption (MVo2tot). Total mechanical energy via pressure-volume area (PVA). Contractile efficiency (Econ) and MVo2 of the unloaded contracting heart (MVo2unl). External mechanical efficiency (Eext) from stroke work and MVo2tot. RESULTS--Systolic variables in stunned myocardium were significantly decreased (mean (SD)): aortic flow: 38 (13) v 9 (11) ml/min; LVPmax: 112 (19) v 74 (18) mm Hg; dP/dtmax: 1475 (400) v 1075 (275) mm Hg/s. ESPVR was not significantly decreased, at 138 (73) v 125 (58) mm Hg/ml, but the volume axis intercept was shifted rightward: 0.30 (0.37) v 0.65 (0.25) ml. Likewise, early relaxation was impaired: dP/dtmin (-1275 (250) v -975 (250) mm Hg/s) and tau (37 (7) v 46 (10) ms). LVPed was significantly decreased at 19 (12) v 12 (7) mm Hg, and both the ventricular (end diastolic pressure-volume relation) and the myocardial stiffness (constant k) were increased by 75% and 31%, respectively. Coronary resistance increased non-significantly from 0.83 (0.31) to 1.04 (0.41) mm Hg/(ml/min/100 g). Decreases in PVA (570 (280) v 270 (200) mm Hg.ml/100 g), MVo2tot (40 (9) v 34 (8) microliters/beat/100 g), and MVo2unl (26 (9) v 22 (6) microliters/beat/100 g) did not reach significance, in contrast to significant decreases in Econ (31 (18) v 14 (7)%) and Eext (0.75 (0.29) v 0.18 (0.25) arbitrary units). CONCLUSIONS--Ventricular systolic function is decreased after brief episodes of ischaemia. The decrease in diastolic function probably amplifies the systolic deterioration during myocardial stunning. Passive diastolic properties are also changed, shown by increases in both ventricular and myocardial stiffness. The increase in coronary resistance indicates stunning at the vascular level which could limit oxygen supply. With maintained MVo2tot during stunning, external efficiency is decreased. Possible candidates for this metabolic stunning are inadequate excitation-contraction coupling and disturbed O2 utilisation by the contractile apparatus. Images PMID:8624873
Chopski, Steven G; Murad, Nohra M; Fox, Carson S; Stevens, Randy M; Throckmorton, Amy L
2018-05-10
The clinical implementation of mechanical circulatory assistance for a significantly dysfunctional or failing left ventricle as a bridge-to-transplant or bridge-to-recovery is on the rise. Thousands of patients with left-sided heart failure are readily benefitting from these life-saving technologies, and left ventricular failure often leads to severe right ventricular dysfunction or failure. Right ventricular failure (RVF) has a high rate of mortality caused by the risk of multisystem organ failure and prolonged hospitalization for patients after treatment. The use of a blood pump to support the left ventricle also typically results in an increase in right ventricular preload and may impair right ventricular contractility during left ventricular unloading. Patients with RVF might also suffer from severe pulmonary dysfunction, cardiac defects, congenital heart disease states, or a heterogeneity of cardiophysiologic challenges because of symptomatic congestive heart failure. Thus, the uniqueness and complexity of RVF is emerging as a new domain of significant clinical interest that motivates the development of right ventricular assist devices. In this review, we present the current state-of-the-art for clinically used blood pumps to support adults and pediatric patients with right ventricular dysfunction or failure concomitant with left ventricular failure. New innovative devices specifically for RVF are also highlighted. There continues to be a compelling need for novel treatment options to support patients with significant right heart dysfunction or failure.
Krieger, J; Grucker, D; Sforza, E; Chambron, J; Kurtz, D
1991-10-01
The effects of treatment with nasal continuous positive airway pressure (CPAP) on left ventricular ejection fraction (LVEF) were assessed in 29 patients with obstructive sleep apnea (OSA) in a prospective study using multiple gated equilibrium radionuclide angiocardiography. All patients were evaluated before CPAP treatment was initiated and were reevaluated after one year (mean +/- SE, 415 +/- 6 days), of home treatment with nasal CPAP. The mean LVEF increased from 59 +/- 1 percent to 63 +/- 1 percent (p less than 0.005). The degree of improvement in LVEF was correlated with baseline LVEF (r = 0.54; p less than 0.003), meaning that the lower the baseline value, the greater the increase with treatment. The changes were not different when subgroups of medicated and unmedicated patients were considered separately. These results show that long-term nasal CPAP treatment results in improved left ventricular function in OSA.
Mouws, Elisabeth M J P; Yaksh, Ameeta; Knops, Paul; Kik, Charles; Boersma, Eric; Bogers, Ad J J C; de Groot, Natasja M S
2017-09-01
The prevalence of ventricular dysrhythmias (VD) [ventricular premature beats (VPBs), ventricular couplets (Vcouplets), ventricular runs (Vruns)] after coronary artery bypass grafting (CABG) has so far not been examined. The goal of this study is to examine characteristics of VD and whether they precede ventricular tachyarrhythmias (VTA) during a postoperative follow-up period of 5 days using continuous rhythm registrations. In addition, we determined predictive factors of VD/VTA. Incidences and burdens of VD/VTA were calculated in patients (N=105, 83 male, 65±9 years) undergoing primary, on-pump CABG. Independent risk factors were examined using multivariate analysis. VPBs, Vcouplets, and Vruns occurred in respectively 100%, 82.9%, and 48.6% with corresponding burdens of 0.05%, 0%, and 0%. Sustained ventricular tachycardia (VT) and ventricular fibrillation (VF) did not occur in our cohort. Independent risk factors for VD included male gender, mitral valve insufficiency, hyperlipidemia, and age ≥60 years. VD are common in patients with coronary artery disease after CABG. Despite high incidences of these dysrhythmias, corresponding burdens are low and sustained VT or VF did not occur. Incidences were highest on the first postoperative day and diminished over time. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai
2016-10-01
The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.
Ndrepepa, Gjin; Kastrati, Adnan; Schwaiger, Markus; Mehilli, Julinda; Markwardt, Christina; Dibra, Alban; Dirschinger, Josef; Schömig, Albert
2005-11-01
In patients with acute myocardial infarction (AMI) before primary coronary stenting with adjunct glycoprotein IIb/IIIa receptor blockade, whether residual blood flow in the infarct-related artery (IRA) affects infarct size or myocardial salvage is not known. This study included 118 patients with ST-segment elevation AMI who received coronary stenting plus abciximab. SPECT studies were performed before and 7-14 d after stenting. Patients were divided into a group with initial Thrombolysis in Myocardial Infarction (TIMI) flow grade < or = 1 (77 patients) and a group with initial TIMI flow grade > 1 (41 patients). The initial median perfusion defect and (in brackets) the 25th and 75th percentiles were 29.1% [21.0%; 52.0%] of the left ventricle in patients with TIMI flow grade < or = 1, versus 16.5% [8.0%; 33.1%] of the left ventricle in patients with TIMI flow grade > 1 (P < 0.001). Baseline left ventricular ejection fraction (54.0% [45.0; 63.0] vs. 57.0% [40.0; 62.0], P = 0.623) or extension of hypokinetic region (28.0 [14.0; 41.0] hypokinetic chords vs. 24.0 [13.0; 39.0] hypokinetic chords, P = 0.643) did not differ significantly between the group with TIMI flow grade < or = 1 and the group with TIMI flow grade > 1. Final infarct size was 11.0% [6.1%; 23.5%] of the left ventricle in the group with TIMI flow grade < = 1, versus 6.0% [2.0%; 12.8%] of the left ventricle in the group with TIMI flow > 1 (P = 0.008). Salvage index was 0.58 [0.38; 0.76] in the group with TIMI flow grade < or = 1, versus 0.61 [0.36; 0.74] in the group with TIMI flow grade > 1 (P = 0.952). At the day 14 angiography, patients with TIMI flow grade > 1 had better left ventricular ejection fraction (61.0% [54.0%; 68.0%] vs. 56.5% [42.9%; 65.0%]; P = 0.03) and a smaller hypokinetic region (7 chords [0; 22.0] vs. 16 chords [2.5; 30.0]; P = 0.024) than did patients with TIMI flow grade < or = 1. Preserved blood flow in the IRA in patients with AMI is associated with a smaller area at risk, a smaller infarct, and better recovery of regional and global left ventricular function. The proportion of initial area at risk salvaged by coronary stenting does not seem to depend on residual blood flow in the IRA.
Marom, Gil; Chiu, Wei-Che; Slepian, Marvin J; Bluestein, Danny
2014-01-01
The total artificial heart (TAH) is a bi-ventricular mechanical circulatory support device that replaces the heart in patients with end-stage congestive heart failure. The device acts as blood pump via pneumatic activation of diaphragms altering the volume of the ventricular chambers. Flow in and out of the ventricles is controlled by mechanical heart valves. The aim of this study is to evaluate the flow regime in the TAH and to estimate the thrombogenic potential during systole. Toward that goal, three numerical models of TAHs of differing sizes, that include the deforming diaphragm and the blood flow from the left chamber to the aorta, are introduced. A multiphase model with injection of platelet particles is employed to calculate their trajectories. The shear stress accumulation in the three models are calculated along the platelets trajectories and their probability density functions, which represent the `thrombogenic footprint' of the device are compared. The calculated flow regime successfully captures the mitral regurgitation and the flows that open and close the aortic valve during systole. Physiological velocity magnitudes are found in all three models, with higher velocities and increased stress accumulation predicted for smaller devices.
Moreno, Beatriz; de Faria, Ana Paula; Ritter, Alessandra Mileni Versuti; Yugar, Lara Buonalumi Tacito; Ferreira-Melo, Silvia Elaine; Amorim, Rivadavio; Modolo, Rodrigo; Fattori, André; Yugar-Toledo, Juan Carlos; Coca, Antonio; Moreno, Heitor
2018-05-01
This study aimed to evaluate the effects of glycated hemoglobin (HbA 1c ) on flow-mediated dilation, intima-media thickness, pulse wave velocity, and left ventricular mass index in patients with resistant hypertension (RHTN) comparing RHTN-controlled diabetes mellitus and RHTN-uncontrolled type 2 diabetes mellitus. Two groups were formed: HbA 1c <7.0% (RHTN-controlled diabetes mellitus: n = 98) and HbA 1c ≥7.0% (RHTN-uncontrolled diabetes mellitus: n = 122). Intima-media thickness and flow-mediated dilation were measured by high-resolution ultrasound, left ventricular mass index by echocardiography, and arterial stiffness by carotid-femoral pulse wave velocity. No differences in blood pressure levels were found between the groups but body mass index was higher in patients with RHTN-uncontrolled diabetes mellitus. Endothelial dysfunction and arterial stiffness were worse in patients with RHTN-uncontrolled diabetes mellitus. Intima-media thickness and left ventricular mass index measurements were similar between the groups. After adjustments, multiple linear regression analyses showed that HbA 1c was an independent predictor of flow-mediated dilation and pulse wave velocity in all patients with RHTN. In conclusion, HbA 1c may predict the grade of arterial stiffness and endothelial dysfunction in patients with RHTN, and superimposed uncontrolled diabetes mellitus implicates further impairment of vascular function. ©2018 Wiley Periodicals, Inc.
Burattini, R; Sipkema, P; van Huis, G A; Westerhof, N
1985-01-01
This study was performed to elucidate the effects of cardiac contraction on coronary pressure-flow relations. On the basis of the waterfall mechanism, a lumped model of the coronary arterial system is presented consisting of a proximal (epicardial) compliance, a coronary resistance, and an intramyocardial compliance. A "back"-pressure, assumed to be proportional (constant k) to left ventricular pressure, impedes flow. From steady-state measurements of circumflex coronary artery flow and inflow pressure, together with left ventricular pressure, the values of the three model parameters and the constant k have been estimated. In the control condition proximal compliance is found to be 1.7 X 10(-12) m4s2kg-1, intramyocardial compliance 110 X 10(-12)m4s2kg-1, and resistance 7.5 X 10(9) kgm-4s-1. The proportionality constant k is close to unity. Effects of changes in left ventricular pressure and inflow pressure and the effect of vasoactive drugs on the parameters are also investigated. Changes in coronary resistance are always opposite to changes in intramyocardial compliance. Sensitivity analysis showed that epicardial compliance plays its major role during isovolumic contraction and relaxation; resistance plays a role throughout the cardiac cycle but is more important in diastole than in systole, whereas intramyocardial compliance plays a role in systole and in early diastole.
Myocardial metabolism during exposure to carbon monoxide in the conscious dog.
NASA Technical Reports Server (NTRS)
Adams, J. D.; Erickson, H. H.; Stone, H. L.
1973-01-01
Investigation of the relationship between coronary flow, heart rate, left ventricular function, and myocardial oxygen consumption at increasing levels of carboxyhemoglobin in conscious dogs. The results demonstrate a linear increase in coronary flow and heart rate as the carboxyhemoglobin increases up to 20%. Myocardial oxygen consumption declined during the same period.
Pulsatile flow in the aorta of the LVAD supported heart studied using particle image velocimetry
NASA Astrophysics Data System (ADS)
Moyedi, Zahra
Currently many patients die because of the end-stage heart failure, mainly due to the reduced number of donor heart transplant organs. Studies show that a permanent left ventricular assist device (LVAD), a battery driven pump which is surgically implanted, increased the survival rate of patients with end-stage heart failure and improved considerably their quality of life. The inlet conduit of the LVAD is attached to the left ventricle and the outflow conduit anastomosed to the ascending aorta. The purpose of LVAD support is to help a weakened heart to pump blood to the rest of the body. However LVAD can cause some alterations of the natural blood flow. When your blood comes in contact with something that isn't a natural part of your body blood clots can occur and disrupt blood flow. Aortic valve integrity is vital for optimal support of left ventricular assist LVAD. Due to the existence of high continuous transvalvular pressure on the aortic valve, the opening frequency of the valve is reduced. To prevent the development of aortic insufficiency, aortic valve closure during LVAD implantation has been performed. However, the closed aortic valve reduces wash out of the aortic root, which causes blood stagnation and potential thrombus formation. So for this reason, there is a need to minimize the risks of occurring blood clot, by having more knowledge about the flow structure in the aorta during LVAD use. The current study focuses on measuring the flow field in the aorta of the LVAD assisted heart with two different types of aortic valve (Flat and Finned) using the SDSU cardiac simulator. The pulsatile pump that mimics the natural pulsing action of the heart also added to the system. The flow field is visualized using Particle Image Velocimetry (PIV). Furthermore, The fluid mechanics of aorta has been studied when LVAD conduit attached to two different locations (proximal and distal to the aortic valve) with pump speeds of 8,000 to 10,000 revolutions per minute (RPM). As LVAD speed increases, the velocity of the defined area (close to the proximal anastomosis) increases linearly but inversely the stagnation index decreases. We observed that with Finned valve attachment, the stagnation value is lower than the flat valve so the results suggest that D1 valve has lower risk of thrombosis close to the aortic valve.
Assessment of mechanical ventricular synchrony in Doberman Pinschers with dilated cardiomyopathy.
López-Alvarez, Jordi; Fonfara, Sonja; Pedro, Brigite; Stephenson, Hannah; Cripps, Peter J; Dukes-McEwan, Joanna
2011-09-01
Loss of temporal synchrony of myocardial contraction has been shown to reduce systolic function and be responsible for disease progression in people. The objective of this study is the assessment of inter- and intra ventricular synchrony in healthy Doberman Pinschers and those with dilated cardiomyopathy (DCM) by use of conventional Doppler and tissue velocity imaging. A total of 60 scans from 35 client-owned Doberman Pinschers presented for cardiac evaluation were analysed. Retrospective analysis of data. Using the European Society of Veterinary Cardiology DCM taskforce scoring system, Doberman Pinschers were classified into 4 groups: Control (Group 1; n=12), depressed systolic function other than DCM (Group 2; n=9), preclinical DCM (Group 3; n=8) and symptomatic DCM (Group 4; n=6). The time intervals between the beginning of the QRS complex and the peak velocity of pulmonic flow (Q-P) and the peak aortic flow (Q-Ao) were used to assess global synchrony between both ventricles. The time intervals between the beginning of the QRS complex and the peak myocardial systolic velocity (Q-peak S) and the onset of myocardial systolic velocity (Q-start S) were measured at the base of the right and left ventricular free wall (RVFW and LVFW) and interventricular septum (IVS), and used to determine segmental longitudinal inter- and intra ventricular synchrony. No significant loss of global or segmental longitudinal inter- or intra ventricular synchrony was identified between the groups. Impairment of longitudinal fibre synchrony does not appear to be significantly associated with clinical status of DCM in Doberman Pinschers, although it was identified in certain individuals. Copyright © 2011 Elsevier B.V. All rights reserved.
Brain Emboli After Left Ventricular Endocardial Ablation.
Whitman, Isaac R; Gladstone, Rachel A; Badhwar, Nitish; Hsia, Henry H; Lee, Byron K; Josephson, S Andrew; Meisel, Karl M; Dillon, William P; Hess, Christopher P; Gerstenfeld, Edward P; Marcus, Gregory M
2017-02-28
Catheter ablation for ventricular tachycardia and premature ventricular complexes (PVCs) is common. Catheter ablation of atrial fibrillation is associated with a risk of cerebral emboli attributed to cardioversions and numerous ablation lesions in the low-flow left atrium, but cerebral embolic risk in ventricular ablation has not been evaluated. We enrolled 18 consecutive patients meeting study criteria scheduled for ventricular tachycardia or PVC ablation over a 9-month period. Patients undergoing left ventricular (LV) ablation were compared with a control group of those undergoing right ventricular ablation only. Patients were excluded if they had implantable cardioverter defibrillators or permanent pacemakers. Radiofrequency energy was used for ablation in all cases and heparin was administered with goal-activated clotting times of 300 to 400 seconds for all LV procedures. Pre- and postprocedural brain MRI was performed on each patient within a week of the ablation procedure. Embolic infarcts were defined as new foci of reduced diffusion and high signal intensity on fluid-attenuated inversion recovery brain MRI within a vascular distribution. The mean age was 58 years, half of the patients were men, half had a history of hypertension, and the majority had no known vascular disease or heart failure. LV ablation was performed in 12 patients (ventricular tachycardia, n=2; PVC, n=10) and right ventricular ablation was performed exclusively in 6 patients (ventricular tachycardia, n=1; PVC, n=5). Seven patients (58%) undergoing LV ablation experienced a total of 16 cerebral emboli, in comparison with zero patients undergoing right ventricular ablation ( P =0.04). Seven of 11 patients (63%) undergoing a retrograde approach to the LV developed at least 1 new brain lesion. More than half of patients undergoing routine LV ablation procedures (predominately PVC ablations) experienced new brain emboli after the procedure. Future research is critical to understanding the long-term consequences of these lesions and to determining optimal strategies to avoid them. © 2017 American Heart Association, Inc.
The late open infarct-related artery hypothesis: evidence-based medicine or not?
Brueck, Martin; Bandorski, Dirk; Kramer, Wilfried; Vogt, Paul R; Heidt, Martin C
2007-11-01
Randomized clinical trials have clearly shown that early reperfusion of coronary arteries is the established treatment of myocardial infarction preserving left ventricular function and reducing mortality. However, late patency of the infarct-related artery is an independent predictor of survival leading to the late open-artery hypothesis. This concept implies restoration of antegrade blood flow of the infarct-related artery in patients with myocardial infarction to improve survival by mechanisms less time-dependent or even time-independent. Possible explanations for this benefit include improved left ventricular function and electrical stability by perfusion of hibernating myocardium, accelerated infarct healing and limitation of ventricular remodeling. This review focuses on the evidence of late recanalization of occluded infarct-related arteries in patients with coronary artery disease.
Blood Pump Development Using Rocket Engine Flow Simulation Technology
NASA Technical Reports Server (NTRS)
Kiris, Cetin C.; Kwak, Dochan
2002-01-01
This viewgraph presentation provides information on the transfer of rocket engine flow simulation technology to work involving the development of blood pumps. Details are offered regarding the design and requirements of mechanical heart assist devices, or VADs (ventricular assist device). There are various computational fluid dynamics issues involved in the visualization of flow in such devices, and these are highlighted and compared to those of rocket turbopumps.
Numerical Analyses for Low Reynolds Flow in a Ventricular Assist Device.
Lopes, Guilherme; Bock, Eduardo; Gómez, Luben
2017-06-01
Scientific and technological advances in blood pump developments have been driven by their importance in cardiac patient treatments and in the expansion of life quality in assisted people. To improve and optimize the design and development, numerical tools were incorporated into the analyses of these mechanisms and have become indispensable in their advances. This study analyzes the flow behavior with low impeller Reynolds number, for which there is no consensus on the full development of turbulence in ventricular assist devices (VAD). For supporting analyses, computational numerical simulations were carried out in different scenarios with the same rotation speed. Two modeling approaches were applied: laminar flow and turbulent flow with the standard, RNG and realizable κ - ε; the standard and SST κ - ω models; and Spalart-Allmaras models. The results agree with the literature for VAD and the range for transient flows in stirred tanks with an impeller Reynolds number around 2800 for the tested scenarios. The turbulent models were compared, and it is suggested, based on the expected physical behavior, the use of κ-ε RNG, standard and SST κ-ω, and Spalart-Allmaras models to numerical analyses for low impeller Reynolds numbers according to the tested flow scenarios. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Iseler, Jackeline; Fox, John; Wierenga, Kelly
2018-06-01
The 30-day readmission rate for patients with a left ventricular assist device implantation at a large, urban, Midwest hospital system (from October 2013 to September 2014) was estimated at 32.1%. Readmission rates were a concern at this facility. Review of the readmissions, change in practice, and home expectations of patients and families have identified an opportunity to improve the transitions of care for this left ventricular assist device (LVAD) program. Therefore, the purpose of this project was to evaluate the effectiveness and feasibility of a transitional care model (TCM) for care of patients with left ventricular devices. Ten patients were enrolled in the pilot that was implemented in June 2015. A transitional care nurse trained to support patients with ventricular assist devices was used to facilitate patient flow. The goal was to create an individualized plan for the development or improvement of self-management skills to decrease readmission rates. The transitional care nurse collaborated with the ventricular device team. The 30-day readmission rate during the pilot was 14.3% compared to the previous annual overall rate of 42.6%. Based on these results, further research is recommended into interventions consistent with the TCM to advance care coordination and to facilitate care transition in the this fragile patient population.
Birch, A A; Eynon, C A; Schley, D
2006-01-01
The objective of this report is to highlight the potential for false pressure measurements from systems that combine intracranial pressure (ICP) measurement and ventricular drainage. If the ports of the drain become blocked to the extent that they present a high resistance to cerebrospinal fluid flow, then a significant pressure gradient between the inside and outside of the catheter may be established. Thus, any intracatheter transducer will faithfully record a pressure much lower than true ICP. This holds true for catheter-tip transducers when the transducer lies inside the catheter. In the absence of flow, however, pressures will equalize; therefore, accurate measurements may be taken if the drain is temporarily closed. We model this situation and provide simulations of expected measurements in such situations; these compare well to observed clinical readings.
Magder, Sheldon
2007-12-01
Discussions of cardiac physiology and pathophysiology most often emphasise the function of the left heart. However, right heart dysfunction plays an important role in critically ill patients and is often not recognised. This is probably because the role of the right ventricle is for generating flow more than pressure, and flow is not easy to evaluate. Of importance, when right ventricular function limits cardiac output, assessing left ventricular function gives little indication of overall cardiac performance. It has recently become evident that the right ventricle also has different genetic origins and characteristics from the left ventricle. The right and left ventricles interact through series effects, diastolic interactions and systolic interactions. The mechanisms of these, and their physiological and pathological significance are discussed.
Patel, Rajan P; Sitton, Clark W; Ketonen, Leena M; Hou, Ping; Johnson, Jason M; Romo, Seferino; Fletcher, Stephen; Shah, Manish N; Kerr, Marcia; Zaky, Wafik; Rytting, Michael E; Khatua, Soumen; Sandberg, David I
2018-03-01
Nuclear medicine studies have previously been utilized to assess for blockage of cerebrospinal fluid (CSF) flow prior to intraventricular chemotherapy infusions. To assess CSF flow without nuclear medicine studies, we obtained cine phase-contrast MRI sequences that assess CSF flow from the fourth ventricle down to the sacrum. In three clinical trials, 18 patients with recurrent malignant posterior fossa tumors underwent implantation of a ventricular access device (VAD) into the fourth ventricle, either with or without simultaneous tumor resection. Prior to infusing therapeutic agents into the VAD, cine MRI phase-contrast CSF flow sequences of the brain and total spine were performed. Velocity encoding (VENC) of 5 and 10 cm/s was used to confirm CSF flow from the fourth ventricular outlets to the cervical, thoracic, and lumbar spine. Qualitative CSF flow was characterized by neuroradiologists as present or absent. All 18 patients demonstrated CSF flow from the outlets of the fourth ventricle down to the sacrum with no evidence of obstruction. One of these patients, after disease progression, subsequently showed obstruction of CSF flow. No patient required a nuclear medicine study to assess CSF flow prior to initiation of infusions. Fourteen patients have received infusions to date, and none has had neurological toxicity. CSF flow including the fourth ventricle and the total spine can be assessed noninvasively with phase-contrast MRI sequences. Advantages over nuclear medicine studies include avoiding both an invasive procedure and radiation exposure.
Sinha, Santosh Kumar; Khanra, Dibbendhu; Jha, Mukesh Jitendra; Singh, Karandeep; Razi, Mahamdulla; Goel, Amit; Mishra, Vikas; Asif, Mohammad; Sachan, Mohit; Afdaali, Nasar; Kumar, Ashutosh; Thakur, Ramesh; Krishna, Vinay; Pandey, Umeshwar; Varma, Chandra Mohan
2016-10-01
ALCAPA syndrome (anomalous origin of the left coronary artery from the pulmonary artery) is a rare disease but lethal with clinical expression from myocardial infarction, congestive heart failure to death during early infancy and unusual survival to adulthood. We report a 73-year-old woman with ALCAPA who presented with exertional dyspnea (NYHA functional class II) over past 2 years. Physical examination revealed soft S, long mid diastolic rumbling murmur and apical pan-systolic murmur. Electrocardiography displayed biatrial enlargement and poor R progression and normal sinus rhythm. Echocardiography established calcified severe mitral stenosis (MS), presence of continuous flow entering the pulmonary trunk, turbulent continuous flow in inter-ventricular septum with left to right shunt in contrast echocardiography and normal systolic function. Coronary angiogram showed absence of left coronary artery (LCA) originating from aorta, dilated and tortuous right coronary artery (RCA) and abundant Rentrop grade 3 intercoronary collateral communicating with LCA originating from pulmonary trunk which was also confirmed on coronary CT angiogram thus establishing diagnosis of ALCAPA. It is exceedingly rare to be associated with severe MS. However, such a long survival in our patient can be explained by the severe pulmonary arterial hypertension which may be contributing to lesser coronary steal.
Sgarra, Luca; Leo, Valentina; Addabbo, Francesco; Iacobazzi, Dominga; Carratù, Maria Rosaria; Montagnani, Monica; Potenza, Maria Assunta
2014-01-01
The angiotensin (Ang) and bradykinin (BK) tissue-system plays a pivotal role in post-conditioning, but the efficacy of angiotensin type 1 receptor (AT1R) blockers (ARBs) in post-ischemic strategies is still under investigation. We evaluated functional and morphological outcomes, together with activation of cytosolic RISK pathway kinases, in rat hearts subjected to losartan (LOS) or irbesartan (IRB) post-ischemic administration. Isolated rat hearts underwent 30 min ischemia and 120 min reperfusion. Post-conditioning was obtained by intermittent (10 s/each) or continuous drug infusion during the first 3 min of reperfusion. Left ventricular end-diastolic pressure (LVEDP), left ventricular developed pressure (dLVP), coronary flow (CF), and left ventricular infarct mass (IM) were measured together with the activation status of RISK kinases Akt, p42/44 MAPK and GSK3β. When compared to hearts subjected to ischemia/reperfusion (iI/R) alone, continuous IRB or LOS administration did not significantly reduce total infarct mass (cIRB or cLOS vs. iI/R, p = 0.2). Similarly, intermittent IRB (iIRB) was not able to enhance cardioprotection. Conversely, intermittent LOS administration (iLOS) significantly ameliorated cardiac recovery (iLOS vs iI/R, p<0.01). Differences between iLOS and iIRB persisted under continuous blockade of AT2R (iLOS+cPD vs. iIRB+cPD, p<0.05). Interestingly, iLOS cardioprotection was lost when BK2R was simultaneously blocked (iLOS+cHOE vs. iI/R, p = 0.6), whereas concurrent administration of iBK and iIRB replicated iLOS effects (iIRB+iBK vs. iLOS, p = 0.7). At the molecular level, iIRB treatment did not significantly activate RISK kinases, whereas both iLOS and iBK treatments were associated with activation of the Akt/GSK3β branch of the RISK pathways (p<0.05 vs. iI/R, for both). Our results suggest that intermittent losartan is effective in mediating post-conditioning cardioprotection, whereas irbesartan is not. The infarct mass reduction by intermittent losartan seem mainly related on its specific ability to modulate BK2R, and only modestly associated on AT1R blocking properties.
Sgarra, Luca; Leo, Valentina; Addabbo, Francesco; Iacobazzi, Dominga; Carratù, Maria Rosaria; Montagnani, Monica; Potenza, Maria Assunta
2014-01-01
Introduction The angiotensin (Ang) and bradykinin (BK) tissue-system plays a pivotal role in post-conditioning, but the efficacy of angiotensin type 1 receptor (AT1R) blockers (ARBs) in post-ischemic strategies is still under investigation. We evaluated functional and morphological outcomes, together with activation of cytosolic RISK pathway kinases, in rat hearts subjected to losartan (LOS) or irbesartan (IRB) post-ischemic administration. Methods Isolated rat hearts underwent 30 min ischemia and 120 min reperfusion. Post-conditioning was obtained by intermittent (10 s/each) or continuous drug infusion during the first 3 min of reperfusion. Left ventricular end-diastolic pressure (LVEDP), left ventricular developed pressure (dLVP), coronary flow (CF), and left ventricular infarct mass (IM) were measured together with the activation status of RISK kinases Akt, p42/44 MAPK and GSK3β. Results When compared to hearts subjected to ischemia/reperfusion (iI/R) alone, continuous IRB or LOS administration did not significantly reduce total infarct mass (cIRB or cLOS vs. iI/R, p = 0.2). Similarly, intermittent IRB (iIRB) was not able to enhance cardioprotection. Conversely, intermittent LOS administration (iLOS) significantly ameliorated cardiac recovery (iLOS vs iI/R, p<0.01). Differences between iLOS and iIRB persisted under continuous blockade of AT2R (iLOS+cPD vs. iIRB+cPD, p<0.05). Interestingly, iLOS cardioprotection was lost when BK2R was simultaneously blocked (iLOS+cHOE vs. iI/R, p = 0.6), whereas concurrent administration of iBK and iIRB replicated iLOS effects (iIRB+iBK vs. iLOS, p = 0.7). At the molecular level, iIRB treatment did not significantly activate RISK kinases, whereas both iLOS and iBK treatments were associated with activation of the Akt/GSK3β branch of the RISK pathways (p<0.05 vs. iI/R, for both). Conclusions Our results suggest that intermittent losartan is effective in mediating post-conditioning cardioprotection, whereas irbesartan is not. The infarct mass reduction by intermittent losartan seem mainly related on its specific ability to modulate BK2R, and only modestly associated on AT1R blocking properties. PMID:24520397
New continuous-flow total artificial heart and vascular permeability.
Feng, Jun; Cohn, William E; Parnis, Steven M; Sodha, Neel R; Clements, Richard T; Sellke, Nicholas; Frazier, O Howard; Sellke, Frank W
2015-12-01
We tested the short-term effects of completely nonpulsatile versus pulsatile circulation after ventricular excision and replacement with total implantable pumps in an animal model on peripheral vascular permeability. Ten calves underwent cardiac replacement with two HeartMate III continuous-flow rotary pumps. In five calves, the pump speed was rapidly modulated to impart a low-frequency pulse pressure in the physiologic range (10-25 mm Hg) at a rate of 40 pulses per minute (PP). The remaining five calves were supported with a pulseless systemic circulation and no modulation of pump speed (NP). Skeletal muscle biopsies were obtained before cardiac replacement (baseline) and on postoperative days (PODs) 1, 7, and 14. Skeletal muscle-tissue water content was measured, and morphologic alterations of skeletal muscle were assessed. VE-cadherin, phospho-VE-cadherin, and CD31 were analyzed by immunohistochemistry. There were no significant changes in tissue water content and skeletal muscle morphology within group or between groups at baseline, PODs 1, 7, and 14, respectively. There were no significant alterations in the expression and/or distribution of VE-cadherin, phospho-VE-cadherin, and CD31 in skeletal muscle vasculature at baseline, PODs 1, 7, and 14 within each group or between the two groups, respectively. Although continuous-flow total artificial heart (CFTAH) with or without a pulse pressure caused slight increase in tissue water content and histologic damage scores at PODs 7 and 14, it failed to reach statistical significance. There was no significant adherens-junction protein degradation and phosphorylation in calf skeletal muscle microvasculature after CFTAH implantation, suggesting that short term of CFTAH with or without pulse pressure did not cause peripheral endothelial injury and did not increase the peripheral microvascular permeability. Copyright © 2015 Elsevier Inc. All rights reserved.
Heart failure treated with low-dose milrinone in a full-term newborn.
Sebková, S; Tomek, V; Zemanová, P; Janota, J
2012-01-01
A term newborn with a hypocontractile myocardium complicating persistent pulmonary hypertension of the newborn was successfully treated with a low-dose phosphodiesterase III inhibitor milrinone. Echocardiography diagnosed heart failure with a left ventricular ejection fraction of 35% and a left ventricular shortening fraction of 18% and severe persistent pulmonary hypertension of the newborn with oxygenation index of 28. Milrinone was started at an initial dose of 50 mcg/kg, followed by continuous infusion of 0.20 mcg/kg/min. With lowdose milrinone oxygenation index decreased to 3 within 6 hours, left ventricular ejection fraction and left ventricular shortening fraction increased to 57%, and 30%, respectively. Low doses of milrinone might be promising in the treatment of heart failure and persistent pulmonary hypertension of the newborn in term newborns.
Development of a prototype magnetically suspended rotor ventricular assist device.
Bearnson, G B; Maslen, E H; Olsen, D B; Allaire, P E; Khanwilkar, P S; Long, J W; Kim, H C
1996-01-01
A continuous flow centrifugal blood pump with magnetically suspended impeller has been designed, constructed, and tested. The system can be functionally divided into three subsystem designs: 1) centrifugal pump and flow paths, 2) magnetic bearings, and 3) brushless DC motor. The centrifugal pump is a Francis vane type design with a designed operating point of 6 L/min flow and 100 mmHg pressure rise at 2,300 RPM. Peak hydraulic efficiency is over 50%. The magnetic bearing system is an all active design with five axes of control. Rotor position sensors were developed as part of the system to provide feedback to a proportional-integral-derivative controller. The motor is a sensorless brushless DC motor. Back electromotive force voltage generated by the motor is used to provide commutation for the motor. No slots are employed in the motor design in order to reduce the radial force that the bearings must generate. Tests pumping blood in vitro were very encouraging; an index of hemolysis of 0.0086 +/- 0.0012 was measured. Further design refinement is needed to reduce power dissipation and size of the device. The concept of using magnetic bearings in a blood pump shows promise in a long-term implantable blood pump.
The role of intraventricular vortices in the left ventricular filling?
NASA Astrophysics Data System (ADS)
Martinez-Legazpi, Pablo; Bermejo, Javier; Benito, Yolanda; Alhama, Marta; Yotti, Raquel; Perez Del Villar, Candelas; Gonzalez-Mansilla, Ana; Barrio, Alicia; Fernandez-Aviles, Francisco; Del Alamo, Juan Carlos
2013-11-01
The generation of vortices during early filling is a salient feature of left ventricular hemodynamics. Existing clinical data suggest that these intraventricular vortices may facilitate pulling flow from the left atrium. To test this hypothesis, we have quantitatively dissected the contribution of the vortex to intraventricular pressure gradients by isolating its induced flow in ultrasound-derived data in 20 patients with non-ischemic dilated cardiomyopathy (NIDCM), 20 age-matched healthy controls and 20 patients with hypertrophied cardiomyopathy. We have observed that, in patients with NIDCM, the hemodynamic forces were shown to be partially supported by the flow inertia whereas that effect was minimized in healthy hearts. In patients with hypertrophied cardiomiopathy such effect was not observed. Supported by grants, PIS09/02603, RD06/0010 (RECAVA), CM12/00273 (to CPV) and BA11/00067 (to JB) from the Instituto de Salud Carlos III, Spain. PML and JCA were partially supported by NIH grant 1R21 HL108268-01.
Prevalence and hemodynamic effects of leaning during CPR
Niles, Dana E.; Sutton, Robert M.; Nadkarni, Vinay M.; Glatz, Andrew; Zuercher, Mathias; Maltese, Matthew R.; Eilevstjønn, Joar; Abella, Benjamin S.; Becker, Lance B.; Berg, Robert A.
2013-01-01
Background Cardiopulmonary resuscitation (CPR) guidelines recommend complete release between chest compressions (CC). Objective Evaluate the hemodynamic effects of leaning (incomplete chest wall release) during CPR and the prevalence of leaning during CPR. Results In piglet ventricular fibrillation cardiac arrests, 10% and 20% (1.8 kg and 3.6 kg, respectively), leaning during CPR increased right atrial pressures, decreased coronary perfusion pressures, and decreased cardiac index and left ventricular myocardial blood flow by nearly 50%. In contrast, residual leaning of a 260 g accelerometer/ force feedback device did not adversely affect cardiac index or myocardial blood flow. Among 108 adult in-hospital CPR events, leaning ≥2.5 kg was demonstrable in 91% of the events and 12% of the evaluated CC. For 12 children with in-hospital CPR, 28% of CC had residual leaning ≥2.5 kg and 89% had residual leaning ≥0.5 kg. Conclusions Leaning during CPR increases intrathoracic pressure, decreases coronary perfusion pressure, and decreases cardiac output and myocardial blood flow. Leaning is common during CPR. PMID:22208173
NASA Technical Reports Server (NTRS)
Firstenberg, M. S.; Vandervoort, P. M.; Greenberg, N. L.; Smedira, N. G.; McCarthy, P. M.; Garcia, M. J.; Thomas, J. D.
2000-01-01
OBJECTIVES: We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND: Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-mode provides a spatiotemporal representation of flow across the mitral valve. METHODS: In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS: From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([deltapI]max = 1.78+/-1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35+/-0.24 vs. 0.81+/-0.15, p< 0.0001). It also allowed an accurate approximation of the peak pressure difference ([deltapc+I]max = 0.95 [delta(p)cathh]max + 0.24, r = 0.96, p<0.001, error = 0.08+/-0.54 mm Hg). CONCLUSIONS: Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart.
Optimal Timing of Heart Transplant After HeartMate II Left Ventricular Assist Device Implantation.
Steffen, Robert J; Blackstone, Eugene H; Smedira, Nicholas G; Soltesz, Edward G; Hoercher, Katherine J; Thuita, Lucy; Starling, Randall C; Mountis, Maria; Moazami, Nader
2017-11-01
Optimal timing of heart transplantation in patients supported with second-generation left ventricular assist devices (LVADs) is unknown. Despite this, patients with LVADs continue to receive priority on the heart transplant waiting list. Our objective was to determine the optimal timing of transplantation for patients bridged with continuous-flow LVADs. A total of 301 HeartMate II LVADs (Thoratec Corp, Pleasanton, CA) were implanted in 285 patients from October 2004 to June 2013, and 86 patients underwent transplantation through the end of follow-up. Optimal transplantation timing was the product of surviving on LVAD support and surviving transplant. Three-year survival after both HeartMate II implantation and heart transplantation was unchanged when transplantation occurred within 9 months of implantation. Survival decreased as the duration of support exceeded this. Preoperative risk factors for death on HeartMate II support were prior valve operation, prior coronary artery bypass grafting, low albumin, low glomerular filtration rate, higher mean arterial pressure, hypertension, and earlier date of implant. Survival for patients without these risk factors was lowest when transplant was performed within 3 months but was relatively constant with increased duration of support. Longer duration of support was associated with poorer survival for patients with many of these risk factors. Device reimplantation, intracranial hemorrhage, and postimplant dialysis during HeartMate II support were associated with decreased survival. Survival of patients supported by the HeartMate II is affected by preoperative comorbidities and postoperative complications. Transplantation before complications is imperative in optimizing survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Double-outlet right ventricle revisited.
Ebadi, Ameneh; Spicer, Diane E; Backer, Carl L; Fricker, F Jay; Anderson, Robert H
2017-08-01
Double-outlet right ventricle is a form of ventriculoarterial connection. The definition formulated by the International Society for Nomenclature of Paediatric and Congenital Heart Disease is based on hearts with both arterial trunks supported in their greater part by a morphologically right ventricle. Bilateral infundibula and ventricular septal defects are highly debated criteria. This study examines the anatomic controversies surrounding double-outlet right ventricle. We show that hearts with double-outlet right ventricle can have atrioventricular-to-arterial valvular continuity. We emphasize the difference between the interventricular communication and the zone of deficient ventricular septation. The hearts examined were from the University of Florida in Gainesville; Johns Hopkins All Children's Hospital, St Petersburg, Fla; and Lurie Children's Hospital, Chicago, Ill. Each specimen had at least 75% of both arterial roots supported by the morphologically right ventricle, with a total of 100 hearts examined. The morphologic method was used to assess anatomic features, including arterial-atrioventricular valvular continuity, subarterial infundibular musculature, and the location of the hole between the ventricles. Most hearts had fibrous continuity between one of the arterial valves and an atrioventricular valve, with bilateral infundibula in 23%, and intact ventricular septum in 5%. Bilateral infundibula are not a defining feature of double-outlet right ventricle, representing only 23% of the specimens in our sample. The interventricular communication can have a posteroinferior muscular rim or extend to become perimembranous (58%). Double-outlet right ventricle can exist with an intact ventricular septum. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.
Ngiam, Jinghao Nicholas; Kuntjoro, Ivandito; Tan, Benjamin Y Q; Sim, Hui-Wen; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong
2017-11-01
Controversy surrounds the prognosis and management of patients with paradoxical low-flow severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF). It was not certain if patients in a particular flow category remained in the same category as disease progressed. We investigated whether there were switches in categories and if so, their predictors. Consecutive subjects (n = 203) with isolated severe AS and paired echocardiography (>180 days apart) were studied. They were divided into 4 groups, based on their flow categories and if they progressed on subsequent echocardiography to switch or remain in the same flow category. Univariate analyses of clinical and echocardiographic parameters identified predictors of these changes in flow category. One hundred eighteen were normal flow (SVI ≥ 35 mL/m 2 ), while 85 were low flow on index echocardiography. In the patients with normal flow, 33% switched to low flow. This was associated with higher valvuloarterial impedance (Zva, P < .001) and lower systemic arterial compliance (SAC, P < .001) compared to index echocardiography, and predicted by higher initial Zva (optimized cutoff >4.77 mm Hg/mL/m 2 , AUC = 0.81 [95% CI:0.75-0.87, P < .001]). In patients with low flow, 25% switched to normal flow, which was associated with lower Zva and higher SAC and the switch was predicted by a higher initial mean transaortic pressure gradient. A significant number of patients switched flow categories in severe AS with preserved LVEF on subsequent echocardiography. Changes in flow were reflected by respective changes in Zva and SAC. Identifying echocardiographic predictors of a switch in category may guide prognostication and management of such patients. © 2017, Wiley Periodicals, Inc.
Vamvakidou, Anastasia; Jin, Wenying; Danylenko, Oleksandr; Chahal, Navtej; Khattar, Rajdeep; Senior, Roxy
2018-03-09
This study aimed to assess the value of low transvalvular flow rate (FR) for the prediction of mortality compared with low stroke volume index (SVi) in patients with low-gradient (mean gradient: <40 mm Hg), low aortic valve area (<1 cm 2 ) aortic stenosis (AS) following aortic valve intervention. Transaortic FR defined as stroke volume/left ventricular ejection time is also a marker of flow; however, no data exist comparing the relative prognostic value of these 2 transvalvular flow markers in patients with low-gradient AS who had undergone valve intervention. We retrospectively followed prospectively assessed consecutive patients with low-gradient, low aortic valve area AS who underwent aortic valve intervention between 2010 and 2014 for all-cause mortality. Of the 218 patients with mean age 75 ± 12 years, 102 (46.8%) had low stroke volume index (SVi) (<35 ml/m 2 ), 95 (43.6%) had low FR (<200 ml/s), and 58 (26.6%) had low left ventricular ejection fraction <50%. The concordance between FR and SVi was 78.8% (p < 0.005). Over a median follow-up of 46.8 ± 21 months, 52 (23.9%) deaths occurred. Patients with low FR had significantly worse outcome compared with those with normal FR (p < 0.005). In patients with low SVi, a low FR conferred a worse outcome than a normal FR (p = 0.005), but FR status did not discriminate outcome in patients with normal SVi. By contrast, SVi did not discriminate survival either in patients with normal or low FR. Low FR was an independent predictor of mortality (p = 0.013) after adjusting for age, clinical prognostic factors, European System for Cardiac Operative Risk Evaluation II, dimensionless velocity index, left ventricular mass index, left ventricular ejection fraction, heart rate, time, type of aortic valve intervention, and SVi (p = 0.59). In patients with low-gradient, low valve area aortic stenosis undergoing aortic valve intervention, low FR, not low SVi, was an independent predictor of medium-term mortality. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Wiencierz, Anne Maria; Kernbach, Manuel; Ecklebe, Josephine; Monnerat, Gustavo; Tomiuk, Stefan; Raulf, Alexandra; Christalla, Peter; Malan, Daniela; Hesse, Michael; Bosio, Andreas; Fleischmann, Bernd K; Eckardt, Dominik
2015-01-01
Central questions such as cardiomyocyte subtype emergence during cardiogenesis or the availability of cardiomyocyte subtypes for cell replacement therapy require selective identification and purification of atrial and ventricular cardiomyocytes. However, current methodologies do not allow for a transgene-free selective isolation of atrial or ventricular cardiomyocytes due to the lack of subtype specific cell surface markers. In order to develop cell surface marker-based isolation procedures for cardiomyocyte subtypes, we performed an antibody-based screening on embryonic mouse hearts. Our data indicate that atrial and ventricular cardiomyocytes are characterized by differential expression of integrin α6 (ITGA6) throughout development and in the adult heart. We discovered that the expression level of this surface marker correlates with the intracellular subtype-specific expression of MLC-2a and MLC-2v on the single cell level and thereby enables the discrimination of cardiomyocyte subtypes by flow cytometry. Based on the differential expression of ITGA6 in atria and ventricles during cardiogenesis, we developed purification protocols for atrial and ventricular cardiomyocytes from mouse hearts. Atrial and ventricular identities of sorted cells were confirmed by expression profiling and patch clamp analysis. Here, we introduce a non-genetic, antibody-based approach to specifically isolate highly pure and viable atrial and ventricular cardiomyocytes from mouse hearts of various developmental stages. This will facilitate in-depth characterization of the individual cellular subsets and support translational research applications.
Wiencierz, Anne Maria; Kernbach, Manuel; Ecklebe, Josephine; Monnerat, Gustavo; Tomiuk, Stefan; Raulf, Alexandra; Christalla, Peter; Malan, Daniela; Hesse, Michael; Bosio, Andreas; Fleischmann, Bernd K.; Eckardt, Dominik
2015-01-01
Rationale Central questions such as cardiomyocyte subtype emergence during cardiogenesis or the availability of cardiomyocyte subtypes for cell replacement therapy require selective identification and purification of atrial and ventricular cardiomyocytes. However, current methodologies do not allow for a transgene-free selective isolation of atrial or ventricular cardiomyocytes due to the lack of subtype specific cell surface markers. Methods and Results In order to develop cell surface marker-based isolation procedures for cardiomyocyte subtypes, we performed an antibody-based screening on embryonic mouse hearts. Our data indicate that atrial and ventricular cardiomyocytes are characterized by differential expression of integrin α6 (ITGA6) throughout development and in the adult heart. We discovered that the expression level of this surface marker correlates with the intracellular subtype-specific expression of MLC-2a and MLC-2v on the single cell level and thereby enables the discrimination of cardiomyocyte subtypes by flow cytometry. Based on the differential expression of ITGA6 in atria and ventricles during cardiogenesis, we developed purification protocols for atrial and ventricular cardiomyocytes from mouse hearts. Atrial and ventricular identities of sorted cells were confirmed by expression profiling and patch clamp analysis. Conclusion Here, we introduce a non-genetic, antibody-based approach to specifically isolate highly pure and viable atrial and ventricular cardiomyocytes from mouse hearts of various developmental stages. This will facilitate in-depth characterization of the individual cellular subsets and support translational research applications. PMID:26618511
Doyle, Mark; Pohost, Gerald M; Bairey Merz, C Noel; Farah, Victor; Shaw, Leslee J; Sopko, George; Rogers, William J; Sharaf, Barry L; Pepine, Carl J; Thompson, Diane V; Rayarao, Geetha; Tauxe, Lindsey; Kelsey, Sheryl F; Biederman, Robert W W
2017-06-01
The Windkessel model of the cardiovascular system, both in its original wind-chamber and flow-pipe form, and in its electrical circuit analog has been used for over a century to modeled left ventricular ejection conditions. Using parameters obtained from aortic flow we formed a Flow Index that is proportional to the impedance of such a "circuit". We show that the impedance varies with ejection fraction (EF) in a manner characteristic of a resonant circuit with multiple resonance points, with each resonance point centrally located in a small range of EF values, i.e., corresponding to multiple contiguous EF bands. Two target populations were used: (I) a development group comprising male and female subjects (n=112) undergoing cardiovascular magnetic resonance (CMR) imaging for a variety of cardiac conditions. The Flow Index was developed using aortic flow data and its relationship to left ventricular EF was shown. (II) An illustration group comprised of female subjects from the Women's Ischemia Syndrome Evaluation (WISE) (n=201) followed for 5 years for occurrence of major adverse cardiovascular events (MACE). Flow data was not available in this group but since the Flow Index was related to the EF we noted the MACE rate with respect to EF. The EFs of the development population covered a wide range (9%-76%) traversing six Flow Index resonance bands. Within each Flow Index resonance band the impedance varied from highly capacitive at the lower range of EF through minimal impedance at resonance, to highly inductive at the higher range of EF, which is characteristic of a resonant circuit. When transitioning from one EF band to a higher band, the Flow Index made a sudden transition from highly inductive to capacitive impedance modes. MACE occurred in 26 (13%) of the WISE (illustration) population. Distance in EF units (Delta center ) from the central location between peaks of MACE activity was derived from EF data and was predictive of MACE rate with an area under the receiver operator curve of 0.73. Of special interest, Delta center was highly predictive of MACE in the sub-set of women with EF >60% (AUC 0.79) while EF was no more predictive than random chance (AUC 0.48). A Flow Index that describes impedance conditions of left ventricular ejection can be calculated using data obtained completely from the ascending aorta. The Flow Index exhibits a periodic variation with EF, and in a separate illustration population the occurrence of MACE was observed to exhibit a similar periodic variation with EF, even in cases of normal EF.
Technological Innovations from NASA
NASA Technical Reports Server (NTRS)
Pellis, Neal R.
2006-01-01
The challenge of human space exploration places demands on technology that push concepts and development to the leading edge. In biotechnology and biomedical equipment development, NASA science has been the seed for numerous innovations, many of which are in the commercial arena. The biotechnology effort has led to rational drug design, analytical equipment, and cell culture and tissue engineering strategies. Biomedical research and development has resulted in medical devices that enable diagnosis and treatment advances. NASA Biomedical developments are exemplified in the new laser light scattering analysis for cataracts, the axial flow left ventricular-assist device, non contact electrocardiography, and the guidance system for LASIK surgery. Many more developments are in progress. NASA will continue to advance technologies, incorporating new approaches from basic and applied research, nanotechnology, computational modeling, and database analyses.
Patent ductus arteriosus associated with congenital anomaly of coronary artery.
Maleki, Majid; Azizian, Nassrin; Esmaeilzadeh, Maryam; Moradi, Bahieh
2013-11-01
We reported a case of patent ductus arteriosus (PDA) with congenital anomaly of coronary arteries as abnormal origin of right coronary artery (RCA) and left coronary artery (LCA) from a single ostium of the right coronary sinus. A 21-year-old man referred to our institution for evaluation of cardiac murmur. He has suffered from palpitation and atypical chest pain for three months. On physical examination, a continuous murmur was heard in the second left parasternal space. Transthoracic echocardiography showed normal left and right ventricular size and systolic function (LVEF = 55%). Main pulmonary artery (PA) and left pulmonary artery (LPA) branch were considerably dilated. Considering normal coronary flow, lack of clinical evidence of myocardial ischemia and echocardiography findings, patient underwent surgical closure of PDA via left thoracotomy and after five days discharged uneventfully.
Kumar, Vipin; Jose, John; Jose, V Jacob
2014-01-01
62-year-old female presented with progressive dyspnea NYHA class III for six months. Echocardiography showed normal left ventricular (LV) systolic function, mild biatrial enlargement, an L wave in pulse wave Doppler at mitral inflow and in M mode echocardiography across mitral valve. Tissue Doppler imaging at medial mitral annulus showed an L' wave in mid diastole in addition to E' and A' wave. An L wave in pulse wave Doppler and M mode echocardiography represents continued pulmonary vein mid diastolic flow through the left atrium in to LV across mitral valve after early rapid filling. Presence of an L' wave in these patients associated with higher E/E' is indicative of advance diastolic dysfunction with elevated filling pressures. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
How best to assess right ventricular function by echocardiography*
DiLorenzo, Michael P.; Bhatt, Shivani M.; Mercer-Rosa, Laura
2016-01-01
Right ventricular function is a crucial determinant of long-term outcomes of children with heart disease. Quantification of right ventricular systolic and diastolic performance by echocardiography is of paramount importance, given the prevalence of children with heart disease, particularly those with involvement of the right heart, such as single or systemic right ventricles, tetralogy of Fallot, and pulmonary arterial hypertension. Identification of poor right ventricular performance can provide an opportunity to intervene. In this review, we will go through the different systolic and diastolic indices, as well as their application in practice. Quantification of right ventricular function is possible and should be routinely performed using a combination of different measures, taking into account each disease state. Quantification is extremely useful for individual patient follow-up. Laboratories should continue to strive to optimise reproducibility through quality improvement and quality assurance efforts in addition to investing in technology and training for new, promising techniques, such as three-dimensional echocardiography. PMID:26675593
Bavo, A M; Pouch, A M; Degroote, J; Vierendeels, J; Gorman, J H; Gorman, R C; Segers, P
2017-01-04
As the intracardiac flow field is affected by changes in shape and motility of the heart, intraventricular flow features can provide diagnostic indications. Ventricular flow patterns differ depending on the cardiac condition and the exploration of different clinical cases can provide insights into how flow fields alter in different pathologies. In this study, we applied a patient-specific computational fluid dynamics model of the left ventricle and mitral valve, with prescribed moving boundaries based on transesophageal ultrasound images for three cardiac pathologies, to verify the abnormal flow patterns in impaired hearts. One case (P1) had normal ejection fraction but low stroke volume and cardiac output, P2 showed low stroke volume and reduced ejection fraction, P3 had a dilated ventricle and reduced ejection fraction. The shape of the ventricle and mitral valve, together with the pathology influence the flow field in the left ventricle, leading to distinct flow features. Of particular interest is the pattern of the vortex formation and evolution, influenced by the valvular orifice and the ventricular shape. The base-to-apex pressure difference of maximum 2mmHg is consistent with reported data. We used a CFD model with prescribed boundary motion to describe the intraventricular flow field in three patients with impaired diastolic function. The calculated intraventricular flow dynamics are consistent with the diagnostic patient records and highlight the differences between the different cases. The integration of clinical images and computational techniques, therefore, allows for a deeper investigation intraventricular hemodynamics in patho-physiology. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Yang, Hua; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Kim, Yong Jin; Popovic, Zoran B.; Pu, Min; Greenberg, Neil L.; Cardon, Lisa A.; Eto, Yoko;
2002-01-01
BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.
Zero Flow Global Ischemia-Induced Injuries in Rat Heart Are Attenuated by Natural Honey
Najafi, Moslem; Zahednezhad, Fahimeh; Samadzadeh, Mehrban; Vaez, Haleh
2012-01-01
Purpose: In the present study, effects of preischemic administration of natural honey on cardiac arrhythmias and myocardial infarction size during zero flow global ischemia were investigated in isolated rat heart. Methods: The isolated hearts were subjected to 30 min zero flow global ischemia followed by 120 min reperfusion then perfused by a modified drug free Krebs-Henseleit solution throughout the experiment (control) or the solution containing 0.25, 0.5, 1 and 2% of natural honey for 15 min before induction of global ischemia (treated groups), respectively. Cardiac arrhythmias were determined based on the Lambeth conventions and the infarct size was measured by computerized planimetry. Results: Myocardial infarction size was 55.8±7.8% in the control group, while preischemic perfusion of honey (0.25, 0.5, 1 and 2%) reduced it to 39.3±11, 30.6±5.5 (P<0.01), 17.9±5.6 (P<0.001) and 8.7±1.1% (P<0.001), respectively. A direct linear correlation between honey concentrations and infarction size reduction was observed (R2=0.9948). In addition, total number of ventricular ectopic beats were significantly decreased by all used concentrations of honey (P<0.05) during reperfusion time. Honey (0.25, 0.5 and 1 %) also lowered incidence of irreversible ventricular fibrillation (P<0.05). Moreover, number and duration of ventricular tachycardia were reduced in all honey treated groups. Conclusion: Preischemic administration of natural honey before zero flow global ischemia can protect isolated rat heart against ischemia/reperfusion injuries as reduction of infarction size and arrhythmias. Maybe, antioxidant and free radical scavenging activities of honey, reduction of necrotized tissue and providing energy sources may involve in these cardioprotective effects of honey. PMID:24312788
Ogino, Takashi; Sawada, Masato; Takase, Hiroshi; Nakai, Chiemi; Herranz-Pérez, Vicente; Cebrián-Silla, Arantxa; Kaneko, Naoko; García-Verdugo, José Manuel; Sawamoto, Kazunobu
2016-10-15
In mammals, ventricular walls of the developing brain maintain a neurogenic niche, in which radial glial cells act as neural stem cells (NSCs) and generate new neurons in the embryo. In the adult brain, the neurogenic niche is maintained in the ventricular-subventricular zone (V-SVZ) of the lateral wall of lateral ventricles and the hippocampal dentate gyrus. In the neonatal V-SVZ, radial glial cells transform into astrocytic postnatal NSCs and multiciliated ependymal cells. On the other hand, in zebrafish, radial glial cells continue to cover the surface of the adult telencephalic ventricle and maintain a higher neurogenic potential in the adult brain. However, the cell composition of the neurogenic niche of the aged zebrafish brain has not been investigated. Here we show that multiciliated ependymal cells emerge in the neurogenic niche of the aged zebrafish telencephalon. These multiciliated cells appear predominantly in the dorsal part of the ventral telencephalic ventricular zone, which also contains clusters of migrating new neurons. Scanning electron microscopy and live imaging analyses indicated that these multiple cilia beat coordinately and generate constant fluid flow within the ventral telencephalic ventricle. Analysis of the cell composition by transmission electron microscopy revealed that the neurogenic niche in the aged zebrafish contains different types of cells, with ultrastructures similar to those of ependymal cells, transit-amplifying cells, and migrating new neurons in postnatal mice. These data suggest that the transformation capacity of radial glial cells is conserved but that its timing is different between fish and mice. J. Comp. Neurol. 524:2982-2992, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Load dependence of the effective regurgitant orifice area in a sheep model of aortic regurgitation.
Reimold, S C; Byrne, J G; Caguioa, E S; Lee, C C; Laurence, R G; Peigh, P S; Cohn, L H; Lee, R T
1991-10-01
Treatment of patients with aortic regurgitation with vasodilators reduces regurgitant volume, ventricular dilation and left ventricular mass. Although these effects are presumably due to afterload reduction, it is also possible that the aortic regurgitant orifice area is not constant. To test the latter hypothesis, aortic regurgitation was created in 10 open chest sheep by partial resection of the noncoronary leaflet under direct visualization. Regurgitant flow was measured with an aortic supravalvular electromagnetic probe; aortic and left ventricular pressures were measured with catheter-tipped micromanometer pressure transducers. The effective regurgitant orifice area was calculated by a modification of the continuity equation in a manner similar to the Gorlin equation. The regurgitant orifice area was measured three times: after aortic regurgitation was created, after mean arterial pressure was increased by 15 to 25 mm Hg with intravenous dopamine and after mean arterial pressure was reduced by 15 to 25 mm Hg with intravenous sodium nitroprusside. Comparison of regurgitant volumes and areas obtained after creation of aortic regurgitation and at the conclusion of the experiment in the absence of dopamine or sodium nitroprusside demonstrated no significant change over time. Dopamine administration was associated with an 86 +/- 81% increase in regurgitant volume (p less than 0.01) and a 38 +/- 44% increase in regurgitant orifice area (p less than 0.01). Sodium nitroprusside administration resulted in a 51 +/- 14% decrease in regurgitant volume (p less than 0.001) and a 28 +/- 21% reduction in regurgitant orifice area (p = 0.007). In this model of acute aortic regurgitation, the effective regurgitant orifice area was altered by increasing or decreasing the aortic transvalvular pressure gradient.(ABSTRACT TRUNCATED AT 250 WORDS)
Yost, Gardner; Bhat, Geetha; Pappas, Patroklos; Tatooles, Antone
2018-04-18
Brain natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (ΔBNP = -693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.
Parratt, J R; Winslow, E
1971-06-01
1. The effects of intravenous infusions of quazodine (6,7-dimethoxy-4-ethylquinazoline; MJ-1988) on myocardial blood flow, myocardial metabolic heat production and on general haemodynamics have been studied in cats anaesthetized with sodium pentobarbitone.2. Quazodine (0.25 and 0.5 (mg/kg)/min for 10 min) decreased diastolic blood pressure, peripheral vascular resistance, systolic ejection time and left ventricular end-diastolic pressure. Heart rate, cardiac effort, output and external work and left ventricular dP/dt were markedly increased. These changes are indicative of increased myocardial contractility and peripheral vasodilatation.3. In a dose of (1.0 mg/kg)/min, quazodine had a more marked hypotensive effect, systolic pressure being significantly reduced, and had less effect on left ventricular dP/dt and cardiac effort. Calculated external cardiac work was slightly reduced and there were very occasional nodal arrhythmias.4. Changes in heart rate, aortic dP/dt and diastolic blood pressure induced by quazodine were unaffected by the previous administration of the beta-adrenoceptor blocking agent alprenolol in a dose (1.0 mg/kg) which abolished the effects of isoprenaline.5. In all doses, quazodine markedly increased local blood flow (by 70-540%) around an implanted myocardial heated thermocouple recorder. ;Corrected temperature', an index of local myocardial metabolic heat production, was almost unchanged and it is suggested that increased myocardial contractility, occurring with unchanged metabolic heat production and oxygen consumption, probably results from a concomitant decrease in intramural wall tension.
Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M
2009-04-01
Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.
Lukito, P; Wong, A; Jing, J; Arthur, J F; Marasco, S F; Murphy, D A; Bergin, P J; Shaw, J A; Collecutt, M; Andrews, R K; Gardiner, E E; Davis, A K
2016-11-01
Essentials Relationship of acquired von Willebrand disease (VWD) and platelet dysfunction is explored. Patients with ventricular assist devices and on extracorporeal membrane oxygenation are investigated. Acquired VWD and platelet receptor shedding is demonstrated in the majority of patients. Loss of platelet adhesion receptors glycoprotein (GP) Ibα and GPVI may increase bleeding risk. Background Ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) are associated with bleeding that is not fully explained by anticoagulant or antiplatelet use. Exposure of platelets to elevated shear in vitro leads to increased shedding. Objectives To investigate whether loss of platelet receptors occurs in vivo, and the relationship with acquired von Willebrand syndrome (AVWS). Methods Platelet counts, coagulation tests and von Willebrand factor (VWF) analyses were performed on samples from 21 continuous flow VAD (CF-VAD), 20 ECMO, 12 heart failure and seven aortic stenosis patients. Levels of platelet receptors were measured by flow cytometry or ELISA. Results The loss of high molecular weight VWF multimers was observed in 18 of 19 CF-VAD and 14 of 20 ECMO patients, consistent with AVWS. Platelet receptor shedding was demonstrated by elevated soluble glycoprotein (GP) VI levels in plasma and significantly reduced surface GPIbα and GPVI levels in CF-VAD and ECMO patients as compared with healthy donors. Platelet receptor levels were also significantly reduced in heart failure patients. Conclusions These data link AVWS and increased platelet receptor shedding in patients with CF-VADs or ECMO for the first time. Loss of the platelet surface receptors GPIbα and GPVI in heart failure, CF-VAD and ECMO patients may contribute to ablated platelet adhesion/activation, and limit thrombus formation under high/pathologic shear conditions. © 2016 International Society on Thrombosis and Haemostasis.
Park, Soon J; Milano, Carmelo A; Tatooles, Antone J; Rogers, Joseph G; Adamson, Robert M; Steidley, D Eric; Ewald, Gregory A; Sundareswaran, Kartik S; Farrar, David J; Slaughter, Mark S
2012-03-01
The HeartMate II (HMII) destination therapy (DT) trial demonstrated significant improvements in outcomes in continuous-flow left ventricular assist devices compared with patients implanted with the pulsatile-flow HeartMate XVE. The primary hypothesis of the current study is that trial patients enrolled after the initial data cohort would have better clinical outcomes. Two hundred eighty-one patients who underwent HMII for DT from May 2007 to March 2009 (Mid Trial [MT] group) were compared with the initial 133 HMII patients from March 2005 to May 2007 (Early Trial [ET] group). Patient entry criteria were the same during the 2 time periods. Survival, adverse events, and quality of life were compared between the 2 groups. Baseline characteristics were similar between the groups. Compared with the ET group, patients in the MT group had reduced adverse event rates for bleeding requiring transfusions (1.66 versus 1.13 events per patient-year, P<0.001), sepsis (0.38 versus 0.27, P=0.025), device-related infections (0.47 versus 0.27, P<0.001), and hemorrhagic stroke (0.07 versus 0.03, P=0.01). Other event rates were similar between groups including ischemic stroke (0.06 versus 0.05 events per patient-year, P=0.57). Survival at 1 year in the MT group was 73% versus 68% in the ET group (P=0.21). Additionally, there was a significant reduction in deaths caused by hemorrhagic stroke (P=0.01). Quality of life improvements were significant in both the groups (P<0.001). The benefit of DT therapy with the HMII is confirmed in subsequent trial patients, with improved adverse event rates and a strong trend for improvements in survival. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00121485.
2012-01-01
Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo). These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds). The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling caused a pattern over the thorax quite distinct from that of atrial filling. The in-vivo tests of the HCP with LVot Doppler resulted in a Pearson’s correlation of R = 0.892, and Bland-Altman plotting of SV yielded a mean bias of -1.6 ml and 2SD =14.8 ml. Conclusions The results indicate that the HCP was able to track the changes in ventricular stroke volume reliably. Furthermore, the HCP produced ventricular volume-time curves that were consistent with the literature, and may be a diagnostic tool as well. PMID:22900831
Single-Center Experience With HeartMate II Left Ventricular Assist Device Explantation.
Tchantchaleishvili, Vakhtang; Cheyne, Christina; Sherazi, Saadia; Melvin, Amber L; Hallinan, William; Chen, Leway; Todd Massey, Howard
2016-12-01
In patients with continuous flow left ventricular assist devices (CF-LVADs) myocardial recovery is uncommon. Given the heterogeneity of the population implanted and low incidence of recovery, the discovery of native left ventricular (LV) recovery and criteria for explantation of CF-LVAD system is not clearly determined. We sought to analyze the characteristics of the patients who underwent CF-LVAD explantation at our institution. Prospectively collected data on patients supported with CF-LVADs were reviewed retrospectively. Patients who underwent CF-LVAD explants were identified and their characteristics were analyzed with a focus on patient presentation and determinants of explantability. From November 2006 to June 2014, 223 patients (181 male, 42 female) underwent implantation of HeartMate II LVAD. Seven female (16.7%) and one male (0.6%) patients were explanted (P < 0.001). Mean age was 43 ± 9 years and etiology for cardiomyopathy was ischemic in three (37.5%) patients, nonischemic in four (50%) patients, and mixed in the one (12.5%) male patient of the cohort. Five (62.5%) patients presented acutely with significant hemolysis, and were found to have LV improvement as well as reduced, absent, or reversed diastolic flow velocities on echocardiography. Overall, mean lactate dehydrogenase level before explantation was 1709 ± 1168 U/L compared to the mean baseline level of 601 ± 316 U/L (P = 0.048). Mean LV ejection fraction (LVEF) improved from 17 ± 7% preimplant to 56 ± 11% pre-explantation (P < 0.001). Median number of days on CF-LVAD support was 870 (interquartile range, 209-975) while mean duration of follow-up after the CF-LVAD explantation was 276 ± 240 days. Mean LVEF dropped from 46 ± 19% postexplantation to 34 ± 10% during the most recent follow-up (P = 0.015). At our institution, patients who underwent LVAD explants were predominantly women with nonischemic cardiomyopathy. Clinical evidence of hemolysis and echocardiographic evidence of reduced or absent diastolic flow velocities were common findings in these patients. Over time, patient's native LV function declined in the absence of LVAD (after LVAD explantation). Significant challenges remain in predicting LV recovery and identifying those individuals who have recovered myocardial function significant enough to be explanted. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willerson, J.T.
1979-01-01
Nuclear Cardiology is a well-written, concise compendium of chapters that covers a wide range of topics in nuclear cardiology. Each chapter has been contributed by one or more recognized experts in the field, and the work is thoroughly referened. The physics and physiology of nuclear cardiology, myocardial imaging with /sup 201/Tl and /sup 99m/Tc pyrophosphate, left ventricular and right ventricular function, measurement of coronary blood flow with /sup 133/Xe, and microspheres are discussed, and there are chapters on metabolic imaging with positron emitters and on transmission computerized tomography of the heart.
Bauser-Heaton, Holly; Nguyen, Charles; Tacy, Theresa; Axelrod, David
2015-01-01
This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein's anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein's anomaly. By providing adequate oxygenation independent of the patient's native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.
Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut
2016-05-01
The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015, Wiley Periodicals, Inc.
Reduced coronary flow and resistance reserve in primary scleroderma myocardial disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nitenberg, A.; Foult, J.M.; Kahan, A.
1986-08-01
The maximum coronary vasodilator capacity after intravenous dipyridamole (0.14 mg X kg-1 X min-1 X 4 minutes) was studied in seven patients with primary scleroderma myocardial disease and compared to that of seven control subjects. Hemodynamic data and left ventricular angiographic data were not different in the two groups. The coronary flow reserve was evaluated by the dipyridamole/basal coronary sinus blood flow ratio (D/B CSBF) and the coronary resistance reserve by the dipyridamole/basal coronary resistance ratio (D/B CR). Coronary reserve was greatly impaired in the group with primary scleroderma myocardial disease: D/B CSBF was lower than in the control groupmore » (2.54 +/- 1.37 vs 4.01 +/- 0.56, respectively; p less than 0.05) and D/B CR was higher than in the control group (0.47 +/- 0.25 vs 0.23 +/- 0.04, respectively; p less than 0.05). Such a decreased coronary flow and resistance reserve in patients with primary scleroderma myocardial disease was not explained by an alteration of left ventricular function. It may be an important contributing factor in the pathogenesis of primary scleroderma myocardial disease.« less
Xie, Bin; Yan, Xianfeng
2017-01-01
Purpose. The aim of this study was to compare the effects of high-intensity interval training (INTERVAL) and moderate-intensity continuous training (CONTINUOUS) on aerobic capacity in cardiac patients. Methods. A meta-analysis identified by searching the PubMed, Cochrane Library, EMBASE, and Web of Science databases from inception through December 2016 compared the effects of INTERVAL and CONTINUOUS among cardiac patients. Results. Twenty-one studies involving 736 participants with cardiac diseases were included. Compared with CONTINUOUS, INTERVAL was associated with greater improvement in peak VO2 (mean difference 1.76 mL/kg/min, 95% confidence interval 1.06 to 2.46 mL/kg/min, p < 0.001) and VO2 at AT (mean difference 0.90 mL/kg/min, 95% confidence interval 0.0 to 1.72 mL/kg/min, p = 0.03). No significant difference between the INTERVAL and CONTINUOUS groups was observed in terms of peak heart rate, peak minute ventilation, VE/VCO2 slope and respiratory exchange ratio, body mass, systolic or diastolic blood pressure, triglyceride or low- or high-density lipoprotein cholesterol level, flow-mediated dilation, or left ventricular ejection fraction. Conclusions. This study showed that INTERVAL improves aerobic capacity more effectively than does CONTINUOUS in cardiac patients. Further studies with larger samples are needed to confirm our observations. PMID:28386556
NASA Technical Reports Server (NTRS)
Bauer, Fabrice; Jones, Michael; Shiota, Takahiro; Firstenberg, Michael S.; Qin, Jian Xin; Tsujino, Hiroyuki; Kim, Yong Jin; Sitges, Marta; Cardon, Lisa A.; Zetts, Arthur D.;
2002-01-01
OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.
Calkoen, Emmeline E; Elbaz, Mohammed S M; Westenberg, Jos J M; Kroft, Lucia J M; Hazekamp, Mark G; Roest, Arno A W; van der Geest, Rob J
2015-11-01
During normal left ventricular (LV) filling, a vortex ring structure is formed distal to the left atrioventricular valve (LAVV). Vortex structures contribute to efficient flow organization. We aimed to investigate whether LAVV abnormality in patients with a corrected atrioventricular septal defect (AVSD) has an impact on vortex ring formation. Whole-heart 4D flow MRI was performed in 32 patients (age: 26 ± 12 years), and 30 healthy subjects (age: 25 ± 14 years). Vortex ring cores were detected at peak early (E-peak) and peak late filling (A-peak). When present, the 3-dimensional position and orientation of the vortex ring was defined, and the circularity index was calculated. Through-plane flow over the LAVV, and the vortex formation time (VFT), were quantified to analyze the relationship of vortex flow with the inflow jet. Absence of a vortex ring during E-peak (healthy subjects 0%, vs patients 19%; P = .015), and A-peak (healthy subjects 10% vs patients 44%; P = .008) was more frequent in patients. In 4 patients, this was accompanied by a high VFT (5.1-7.8 vs 2.4 ± 0.6 in healthy subjects), and in another 2 patients with abnormal valve anatomy. In patients compared with controls, the vortex cores had a more-anterior and apical position, closer to the ventricular wall, with a more-elliptical shape and oblique orientation. The shape of the vortex core closely resembled the valve shape, and its orientation was related to the LV inflow direction. This study quantitatively shows the influence of abnormal LAVV and LV inflow on 3D vortex ring formation during LV inflow in patients with corrected AVSD, compared with healthy subjects. Copyright © 2015. Published by Elsevier Inc.
Ko, Byung-Soo; Drakos, Stavros; Kfoury, Abdallah G; Hurst, Denise; Stoddard, Gregory J; Willis, Carrie A; Delgado, Julio C; Hammond, Elizabeth H; Gilbert, Edward M; Alharethi, Rami; Revelo, Monica P; Nativi-Nicolau, Jose; Reid, Bruce B; McKellar, Stephen H; Wever-Pinzon, Omar; Miller, Dylan V; Eckels, David D; Fang, James C; Selzman, Craig H; Stehlik, Josef
2016-08-01
Immune allosensitization can be triggered by continuous-flow left ventricular assist devices (CF LVAD). However, the effect of this type of allosensitization on post-transplant outcomes remains controversial. This study examined the post-transplant course in a contemporary cohort of patients undergoing transplantation with and without LVAD bridging. We included consecutive patients who were considered for cardiac transplant from 2006 to 2015. Serum alloantibodies were detected with single-antigen beads on the Luminex platform (One Lambda Inc., Canoga Park, CA). Allosensitization was defined as calculated panel reactive antibody (cPRA) > 10%. cPRA was determined at multiple times. LVAD-associated allosensitization was defined as development of cPRA > 10% in patients with cPRA ≤ 10% before LVAD implantation. Post-transplant outcomes of interest were acute cellular rejection (ACR), antibody-mediated rejection (AMR), and survival. Allosensitization status was evaluated in 268 patients (20% female). Mean age was 52 ± 12 years, and 132 (49.3%) received CF LVADs. After LVAD implant, 30 patients (23%) became newly sensitized, and the level of sensitization appeared to diminish in many of these patients while awaiting transplant. During the study period, 225 of 268 patients underwent transplant, and 43 did not. A CF LVAD was used to bridge 50% of the transplant recipients. Compared with patients without new sensitization or those already sensitized at baseline, the patients with LVAD-associated sensitization had a higher risk of ACR (p = 0.049) and higher risk of AMR (p = 0.018) but a similar intermediate-term post-transplant survival. The patients who did not receive a transplant had higher level of allosensitization, with a baseline cPRA of 20% vs 6% in those who received an allograft and a high risk (40%) of death during follow-up. New allosensitization takes place in > 20% of patents supported with CF LVADs. Among patients who undergo transplant, this results in a higher risk of ACR and AMR, but survival remains favorable, likely due to the efficacy of current management after transplant. However, mortality in sensitized patients who do not reach transplant remains high, and new approaches are necessary to meet the needs of this group of patients. Published by Elsevier Inc.
Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S
2016-04-01
In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Rossano, Joseph W; Cantor, Ryan S; Dai, Dingwei; Shamszad, Pirouz; Huang, Yuan-Shung; Hall, Matthew; Lin, Kimberly Y; Edens, R Erik; Parrino, P Eugene; Kirklin, James K
2018-06-01
Few data exist on resource utilization with pediatric ventricular assist devices (VADs). We tested the hypothesis that device type and adverse events are associated with increased resource utilization in pediatric patients supported with VADs. The Pediatric Interagency Registry for Mechanically Assisted Circulatory Support, a national registry of VADs in patients <19 years old, and the Pediatric Health Information System, an administrative database, were merged. Univariate analysis was performed assessing the association of all factors with the total cost and length of stay first. Significant variables ( P <0.05) were subjected to multivariable analysis. The study included 142 patients from 19 centers with VAD implants from October 2012 to June 2016. The median age was 9 years (interquartile range [IQR] 2-15), 84 (59%) supported with a continuous-flow VAD. Overall median hospital costs were $750 000 (IQR $539 000 to $1 100 000) with a median hospital length of stay of 81 days (IQR 54-128). On multivariable analysis, device type and postoperative complications were not associated with resource utilization. Factors associated with increased costs included patient age, lower-volume VAD center, being intubated, being on extracorporeal membrane oxygenation, number of complex chronic medical conditions, and length of stay. Among continuous-flow VAD patients, discharge to home before transplant versus remaining hospitalized was associated with lower hospital costs (median $600 000 [IQR $400 000 to $820 000] versus median $680 000 [IQR $500 000 to $970 000], P =0.03). VADs in pediatric patients are associated with high resource utilization. Increased resource utilization was associated with lower-volume VAD centers, disease severity at VAD implantation, and the presence of complex chronic medical conditions. Further study is needed to develop cost-effective strategies in this complex population. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Mynard, Jonathan P; Smolich, Joseph J
2016-07-01
Coronary hemodynamics are known to be affected by intravascular and extravascular factors that vary regionally and transmurally between the perfusion territories of left and right coronary arteries. However, despite clinical evidence that left coronary arterial dominance portends greater cardiovascular risk, relatively little is known about the effects of left or right dominance on regional conduit arterial and microcirculatory blood flow patterns, particularly in the presence of systemic or pulmonary hypertension. We addressed this issue using a multiscale numerical model of the human coronary circulation situated in a closed-loop cardiovascular model. The coronary model represented left or right dominant anatomies and accounted for transmural and regional differences in vascular properties and extravascular compression. Regional coronary flow dynamics of the two anatomical variants were compared under normotensive conditions, raised systemic or pulmonary pressures with maintained flow demand, and after accounting for adaptations known to occur in acute and chronic hypertensive states. Key findings were that 1) right coronary arterial flow patterns were strongly influenced by dominance and systemic/pulmonary hypertension; 2) dominance had minor effects on left coronary arterial and all microvascular flow patterns (aside from mean circumflex flow); 3) although systemic hypertension favorably increased perfusion pressure, this benefit varied regionally and transmurally and was offset by increased left ventricular and septal flow demands; and 4) pulmonary hypertension had a substantial negative effect on right ventricular and septal flows, which was exacerbated by greater metabolic demands. These findings highlight the importance of interactions between coronary arterial dominance and hypertension in modulating coronary hemodynamics. Copyright © 2016 the American Physiological Society.
Saline-Induced Coronary Hyperemia: Mechanisms and Effects on Left Ventricular Function.
De Bruyne, Bernard; Adjedj, Julien; Xaplanteris, Panagiotis; Ferrara, Angela; Mo, Yujing; Penicka, Martin; Floré, Vincent; Pellicano, Mariano; Toth, Gabor; Barbato, Emanuele; Duncker, Dirk J; Pijls, Nico H J
2017-04-01
During thermodilution-based assessment of volumetric coronary blood flow, we observed that intracoronary infusion of saline increased coronary flow. This study aims to quantify the extent and unravel the mechanisms of saline-induced hyperemia. Thirty-three patients were studied; in 24 patients, intracoronary Doppler flow velocity measurements were performed at rest, after intracoronary adenosine, and during increasing infusion rates of saline at room temperature through a dedicated catheter with 4 lateral side holes. In 9 patients, global longitudinal strain and flow propagation velocity were assessed by transthoracic echocardiography during a prolonged intracoronary saline infusion. Taking adenosine-induced maximal hyperemia as reference, intracoronary infusion of saline at rates of 5, 10, 15, and 20 mL/min induced 6%, 46%, 111%, and 112% of maximal hyperemia, respectively. There was a close agreement of maximal saline- and adenosine-induced coronary flow reserve (intraclass correlation coefficient, 0.922; P <0.001). The same infusion rates given through 1 end hole (n=6) or in the contralateral artery (n=6) did not induce a significant increase in flow velocity. Intracoronary saline given on top of an intravenous infusion of adenosine did not further increase flow. Intracoronary saline infusion did not affect blood pressure, systolic, or diastolic left ventricular function. Heart rate decreased by 15% during saline infusion ( P =0.021). Intracoronary infusion of saline at room temperature through a dedicated catheter for coronary thermodilution induces steady-state maximal hyperemia at a flow rate ≥15 mL/min. These findings open new possibilities to measure maximal absolute coronary blood flow and minimal microcirculatory resistance. © 2017 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Assi, Kondo Claude; Gay, Etienne; Chnafa, Christophe; Mendez, Simon; Nicoud, Franck; Abascal, Juan F. P. J.; Lantelme, Pierre; Tournoux, François; Garcia, Damien
2017-09-01
We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an {{\\ell }2} -norm minimization of a cost function composed of a Doppler data-fidelity term and a regularizer. The latter contains three physically interpretable expressions related to 2D mass conservation, Dirichlet boundary conditions, and smoothness. A finite difference discretization of the continuous problem was adopted in a polar coordinate system, leading to a sparse symmetric positive-definite system. The three regularization parameters were determined automatically by analyzing the L-hypersurface, a generalization of the L-curve. The performance of the proposed method was numerically evaluated using (1) a synthetic flow composed of a mixture of divergence-free and curl-free flow fields and (2) simulated flow data from a patient-specific CFD (computational fluid dynamics) model of a human left heart. The numerical evaluations showed that the vector flow fields reconstructed from the Doppler components were in good agreement with the original velocities, with a relative error less than 20%. It was also demonstrated that a perturbation of the domain contour has little effect on the rebuilt velocity fields. The capability of our intraventricular vector flow mapping (iVFM) algorithm was finally illustrated on in vivo echocardiographic color Doppler data acquired in patients. The vortex that forms during the rapid filling was clearly deciphered. This improved iVFM algorithm is expected to have a significant clinical impact in the assessment of diastolic function.
Measurement of blood flow from an assist ventricle by computation of pneumatic driving parameters.
Qian, K X
1992-03-01
The measurement of blood flow from an assist ventricle is important but sometimes difficult in artificial heart experiments. Along with the development of a pneumatic cylinder-piston driver coupled with a ventricular assist device, a simplified method for measuring pump flow was established. From driving parameters such as the piston (or cylinder) displacement and air pressure, the pump flow could be calculated by the use of the equation of state for an ideal gas. The results of this method are broadly in agreement with electromagnetic and Doppler measurements.
Application of full field optical studies for pulsatile flow in a carotid artery phantom
Nemati, M.; Loozen, G. B.; van der Wekken, N.; van de Belt, G.; Urbach, H. P.; Bhattacharya, N.; Kenjeres, S.
2015-01-01
A preliminary comparative measurement between particle imaging velocimetry (PIV) and laser speckle contrast analysis (LASCA) to study pulsatile flow using ventricular assist device in a patient-specific carotid artery phantom is reported. These full-field optical techniques have both been used to study flow and extract complementary parameters. We use the high spatial resolution of PIV to generate a full velocity map of the flow field and the high temporal resolution of LASCA to extract the detailed frequency spectrum of the fluid pulses. Using this combination of techniques a complete study of complex pulsatile flow in an intricate flow network can be studied. PMID:26504652
The Short-Term Effects of Ketogenic Diet on Cardiac Ventricular Functions in Epileptic Children.
Doksöz, Önder; Çeleğen, Kübra; Güzel, Orkide; Yılmaz, Ünsal; Uysal, Utku; İşgüder, Rana; Çeleğen, Mehmet; Meşe, Timur
2015-09-01
Our primary aim was to determine the short-term effects of a ketogenic diet on cardiac ventricular function in patients with refractory epilepsy. Thirty-eight drug-resistant epileptic patients who were treated with a ketogenic diet were enrolled in this prospective study. Echocardiography was performed on all patients before beginning the ketogenic diet and after the sixth month of therapy. Two-dimensional, M-mode, color flow, spectral Doppler, and pulsed-wave tissue Doppler imaging measurements were performed on all patients. The median age of the 32 patients was 45.5 months, and 22 (57.8%) of them were male. Body weight, height, and body mass index increased significantly at the sixth month of therapy when compared with baseline values (P < 0.05). Baseline variables assessed by conventional M-mode echocardiography showed no significant difference at month 6 (P > 0.05). Doppler flow indices of mitral annulus and tricuspid annulus velocity of patients at baseline and month 6 showed no significant differences (P > 0.05). Tricuspid annular E/A ratio was lower at month 6 (P < 0.05). Although mitral annulus tissue Doppler imaging studies showed no significant difference (P > 0.05), there was a decrease in Ea velocity and Ea/Aa ratio gathered from tricuspid annulus at month 6 compared with baseline (P < 0.05). A 6-month duration ketogenic diet does not impair left ventricular functions in children with refractory epilepsy; however, it may be associated with a right ventricular diastolic dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.
Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S
2016-07-08
Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.
Broyd, Christopher J; Rigo, Fausto; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Al-Lamee, Rasha; Foin, Nicolas; Chukwuemeka, Andrew; Anderson, Jon; Parker, Jessica; Malik, Iqbal S; Mikhail, Ghada W; Francis, Darrel P; Parker, Kim; Hughes, Alun D; Mayet, Jamil; Davies, Justin E
2018-06-23
Severe aortic stenosis frequently involves the development of left ventricular hypertrophy (LVH) creating a dichotomous hemodynamic state within the coronary circulation. Whilst the increased force of ventricular contraction enhances its resultant relaxation and thus increases the distal diastolic coronary 'suction' force, the presence of LVH has a potentially opposing effect on ventricular-coronary interplay. The aim of this study was to use non-invasive coronary wave-intensity analysis (WIA) to separate and measure the sequential effects of outflow-tract obstruction relief and then left ventricular hypertrophy (LVH) regression following intervention for aortic stenosis. 15 patients with unobstructed coronary arteries undergoing aortic valve intervention (11 SAVR, 4 TAVI) were successfully assessed before and after intervention, and at 6- and 12-months post-procedure. Coronary WIA was constructed from simultaneously acquired coronary flow from transthoracic echo and pressure from an oscillometric brachial-cuff system. Immediately following intervention, a decline in the BDW was noted (9.7±5.7 vs 5.1±3.6 x10 3 Wm -2 s -1 , p<0.01). Over 12 months, LV mass-index fell from 114±19 to 82±17 kg/m 2 . Accompanying this, the BDW fraction increased to 32.8±7.2% (p=0.01 vs post-procedure) and to 34.7±6.7% at 12 months (p<0.001 vs post-procedure). In aortic stenosis, both the outflow-tract gradient and the presence of LVH impact significantly on coronary haemodynamics that cannot be appreciated by examining resting coronary flow rates alone. An immediate change in coronary wave-intensity occurs following intervention with further effects appreciable with hypertrophy regression. The improvement in prognosis with treatment is likely to be attributable to both features. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Deo, Salil V; Sharma, Vikas; Altarabsheh, Salah E; Hasin, Tal; Dillon, John; Shah, Ishan K; Durham, Lucian A; Stulak, John M; Daly, Richard C; Joyce, Lyle D; Park, Soon J
2014-03-01
Data regarding the long-term clinical effects of a continuous flow left ventricular assist device (CF-LVAD) on hepato-renal function is limited. Hence our aim was to assess changes in hepato-renal function over a one-year period in patients supported on a CF-LVAD. During the study period 126 patients underwent CF-LVAD implant. Changes in hepato-renal laboratory parameters were studied in 61/126 patients successfully supported on a CF-LVAD for period of one year. A separate cohort of a high-risk group (HCrB) of patients (56/126) with a serum creat>1.9 mg/dL (168 μmol/L) (75th percentile) or a serum bil>1.5 mg/dL (25.65 μmol/L) (75th percentile) was created. Changes in serum creatinine and bilirubin were analysed at regular intervals for this group along with the need for renal replacement therapy. Baseline creatinine and blood urea nitrogen (BUN) for the entire cohort was 1.4[1.2,1.9 mg/dL] [123.7(106,168) μmol/L) and 27[20,39.5 mg/dL] [9.6(7.1,14.1) mmol/L] respectively. After an initial reduction at the end of one month [1(0.8,1.2) mg/dL; 88(70,105) μmol/L] (p<0.0001), a gradual increase was noted over the study period to reach (1.25[1.1,1.5] mg/dL; 106(97.2,132.6) μmol/L] (p=0.0003). The serum bilirubin normalised from a [1(0.7,1.55) mg/dL] [17(18.8,25.7) μmol/L) to 0.9(0.6,1.2)mg/dL [15.4(10.2,20.5) μmol/L] (p=0.0005) and continued to decline over one year. Improvement in the synthetic function of the liver was demonstrated by a rise in the serum albumin levels to reach 4.3[4.1,4.5] [43(41,45) gm/L] at the end of one year (p<0.0001). The baseline serum creatinine and bilirubin for the high-risk cohort (HCrB) was 1.9(1.3,2.4) mg/dL [168(115,212) μmol/L] and 1.7(1.00,2.4) mg/dL [29(17.1,68.4) μmol/L] respectively. The high-risk cohort (HCrB) demonstrated a trend towards higher 30-day mortality (p=0.06). While the need for temporary renal replacement therapy was higher in this cohort (16% vs. 4%; p=0.03), only 3% need it permanently. A significant reduction in creatinine was apparent at the end of one month [1.1(0.8,1.4) mg/dL; 97(70.7,123.7) μmol/L] (p<0.0001) and then remained stable at [1.3(1.1,1.5) mg/dL; 115(97,132.6) μmol/L]. Bilirubin demonstrated a 30% decline over one month and then remained low at [0.7(0.5,0.8) mg/dL; 62(44,70) μmol/L] p=0.0005 compared to the pre-operative baseline. Hepato-renal function demonstrates early improvement and then remains stable in the majority of patients on continuous flow left ventricular assist device support for one year. High-risk patients demonstrate a higher 30-day mortality and temporary need for renal replacement therapy. Yet even in this cohort, improvement is present over a period of one year on the device, with a minimal need for permanent haemodialysis. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Desai, Ravi R; Vargas Abello, Lina Maria; Klein, Allan L; Marwick, Thomas H; Krasuski, Richard A; Ye, Ying; Nowicki, Edward R; Rajeswaran, Jeevanantham; Blackstone, Eugene H; Pettersson, Gösta B
2013-11-01
To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant tricuspid valve repair effectively and durably eliminated severe tricuspid regurgitation and improved right ventricular function toward normal, supporting an aggressive approach to important functional tricuspid regurgitation. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Desai, Ravi R.; Vargas Abello, Lina Maria; Klein, Allan L.; Marwick, Thomas H.; Krasuski, Richard A.; Ye, Ying; Nowicki, Edward R.; Rajeswaran, Jeevanantham; Blackstone, Eugene H.; Pettersson, Gösta B.
2014-01-01
Objectives To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. Methods From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+(100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. Results In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. Conclusions In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant tricuspid valve repair effectively and durably eliminated severe tricuspid regurgitation and improved right ventricular function toward normal, supporting an aggressive approach to important functional tricuspid regurgitation. PMID:23010580
Sack, Kevin L; Dabiri, Yaghoub; Franz, Thomas; Solomon, Scott D; Burkhoff, Daniel; Guccione, Julius M
2018-01-01
Predictive computation models offer the potential to uncover the mechanisms of treatments whose actions cannot be easily determined by experimental or imaging techniques. This is particularly relevant for investigating left ventricular mechanical assistance, a therapy for end-stage heart failure, which is increasingly used as more than just a bridge-to-transplant therapy. The high incidence of right ventricular failure following left ventricular assistance reflects an undesired consequence of treatment, which has been hypothesized to be related to the mechanical interdependence between the two ventricles. To investigate the implication of this interdependence specifically in the setting of left ventricular assistance device (LVAD) support, we introduce a patient-specific finite-element model of dilated chronic heart failure. The model geometry and material parameters were calibrated using patient-specific clinical data, producing a mechanical surrogate of the failing in vivo heart that models its dynamic strain and stress throughout the cardiac cycle. The model of the heart was coupled to lumped-parameter circulatory systems to simulate realistic ventricular loading conditions. Finally, the impact of ventricular assistance was investigated by incorporating a pump with pressure-flow characteristics of an LVAD (HeartMate II™ operating between 8 and 12 k RPM) in parallel to the left ventricle. This allowed us to investigate the mechanical impact of acute left ventricular assistance at multiple operating-speeds on right ventricular mechanics and septal wall motion. Our findings show that left ventricular assistance reduces myofiber stress in the left ventricle and, to a lesser extent, right ventricle free wall, while increasing leftward septal-shift with increased operating-speeds. These effects were achieved with secondary, potentially negative effects on the interventricular septum which showed that support from LVADs, introduces unnatural bending of the septum and with it, increased localized stress regions. Left ventricular assistance unloads the left ventricle significantly and shifts the right ventricular pressure-volume-loop toward larger volumes and higher pressures; a consequence of left-to-right ventricular interactions and a leftward septal shift. The methods and results described in the present study are a meaningful advancement of computational efforts to investigate heart-failure therapies in silico and illustrate the potential of computational models to aid understanding of complex mechanical and hemodynamic effects of new therapies.
Chronic animal experiment with magnetically suspended centrifugal pump.
Yamada, T; Nishimura, K; Park, C H; Kono, S; Yuasa, S; Tsukiya, T; Akamatsu, T; Matsuda, K; Ban, T
1997-07-01
We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using sheep. The flow rates ranged from 2.5-5.5 L/min. The sheep that lived the longest (46 days) died of an embolism as a result of the thrombus in the pump. No thrombus formation was observed in other pumps. Plasma free hemoglobin levels ranged from 9 to 18 mg/dl, which led to the conclusion that the hemolysis level remained within an acceptable range. Two driving modes were compared. The slope of the pressure-flow relationship plot under a constant motor current mode was steeper than that under a constant rotational speed mode, and thus, the flow fluctuation decreased. In conclusion, the MSCP is durable for more than a month at the current stage of development and is a promising device for long-term ventricular assist.
Heinz, Boeker; Lorenzo, Perniola; Markus, Risch; Holger, Himmighoffen; Beatrix, Roemer; Erich, Seifritz; Alain, Borgeat
2013-09-01
This report addresses the dilemma of continuing lithium prophylaxis and antidepressant therapy in view of cardiovascular adverse effects under electroconvulsive therapy (ECT) in patients with a long history of recurrent affective disorders. A severely depressed 48-year-old woman who had been treated with lithium for 18 years developed a ventricular tachycardia during ECT. Possible interaction with succinylcholine was taken into account, and rocuronium was used as an alternative muscle relaxant. Electroconvulsive therapy was continued without adverse effects after reduction of lithium and withdrawal from duloxetine. Systemic studies on cardiac adverse effects of serotonin and norepinephrine reuptake inhibitors and serotonin and norepinephrine reuptake inhibitor-lithium combinations during ECT are needed.
Öztürk, Semi; Aktemur, Tuğba; Kalyoncuoğlu, Muhsin; Durmuş, Gündüz; Can, Mehmet
2017-04-01
A 52-year-old man complaining of persistent recurring chest pain at night underwent coronary angiogram at another institution. Normal coronaries were observed and he was discharged with muscle spasmolytic prescription. Since symptoms had continued, 24-hour Holter monitoring was ordered at our facility and results revealed huge ST elevation and polymorphic ventricular tachycardia. Cold pressor test performed in catheterization laboratory also resulted in ventricular tachycardia. Nifedipine was prescribed and follow-up Holter monitoring revealed no further vasospastic episodes. Utility of 24-hour Holter rhythm monitoring and cold pressor test in patients with recurrent chest pain at night is demonstrated in this report.
HeartMate II left ventricular assist system: from concept to first clinical use.
Griffith, B P; Kormos, R L; Borovetz, H S; Litwak, K; Antaki, J F; Poirier, V L; Butler, K C
2001-03-01
The HeartMate II left ventricular assist device (LVAD) (ThermoCardiosystems, Inc, Woburn, MA) has evolved from 1991 when a partnership was struck between the McGowan Center of the University of Pittsburgh and Nimbus Company. Early iterations were conceptually based on axial-flow mini-pumps (Hemopump) and began with purge bearings. As the project developed, so did the understanding of new bearings, computational fluid design and flow visualization, and speed control algorithms. The acquisition of Nimbus by ThermoCardiosystems, Inc (TCI) sped developments of cannulas, controller, and power/monitor units. The system has been successfully tested in more than 40 calves since 1997 and the first human implant occurred in July 2000. Multicenter safety and feasibility trials are planned for Europe and soon thereafter a trial will be started in the United States to test 6-month survival in end-stage heart failure.
Torres-Tirado, David; Knabb, Maureen; Castaño, Irene; Patrón-Soberano, Araceli; De Las Peñas, Alejandro; Rubio, Rafael
2016-01-01
Candida glabrata (CG) is an opportunistic fungal pathogen that initiates infection by binding to host cells via specific lectin-like adhesin proteins. We have previously shown the importance of lectin-oligosaccharide binding in cardiac responses to flow and agonists. Because of the lectinic-oligosaccharide nature of CG binding, we tested the ability of CG to alter the agonist- and flow-induced changes in cardiac function in isolated perfused guinea pig hearts. Both transmission and scanning electron microscopy showed strong attachment of CG to the coronary endothelium, even after extensive washing. CG shifted the coronary flow vs. auricular-ventricular (AV) delay relationship upward, indicating that greater flow was required to achieve the same AV delay. This effect was completely reversed with mannose, partially reversed with galactose and N-acetylgalactosamine, but hyaluronan had no effect. Western blot analysis was used to determine binding of CG to isolated coronary endothelial luminal membrane (CELM) receptors, and the results indicate that flow-sensitive CELM receptors, ANG II type I, α-adrenergic 1A receptor, endothelin-2, and VCAM-1 bind to CG. In addition, CG inhibited agonist-induced effects of bradykinin, angiotensin, and phenylephrine on AV delay, coronary perfusion pressure, and left ventricular pressure. Mannose reversed the inhibitory effects of CG on the agonist responses. These results suggest that CG directly binds to flow-sensitive CELM receptors via lectinic-oligosaccharide interactions with mannose and disrupts the lectin-oligosaccharide binding necessary for flow-induced cardiac responses. Copyright © 2016 the American Physiological Society.
Yannopoulos, Demetris; Bartos, Jason A.; George, Stephen A.; Sideris, George; Voicu, Sebastian; Oestreich, Brett; Matsuura, Timothy; Shekar, Kadambari; Rees, Jennifer; Aufderheide, Tom P.
2017-01-01
Introduction Sodium nitroprusside (SNP) enhanced CPR (SNPeCPR) demonstrates increased vital organ blood flow and survival in multiple porcine models. We developed a new, coronary occlusion/ischemia model of prolonged resuscitation, mimicking the majority of out-of-hospital cardiac arrests presenting with shockable rhythms. Hypothesis SNPeCPR will increase short term (4-hour) survival compared to standard 2015 Advanced Cardiac Life Support (ACLS) guidelines in an ischemic refractory ventricular fibrillation (VF), prolonged CPR model. Methods Sixteen anesthetized pigs had the ostial left anterior descending artery occluded leading to ischemic VF arrest. VF was untreated for 5 minutes. Basic life support was performed for 10 minutes. At minute 10 (EMS arrival), animals received either SNPeCPR (n=8) or standard ACLS (n=8). Defibrillation (200J) occurred every 3 minutes. CPR continued for a total of 45 minutes, then the balloon was deflated simulating revascularization. CPR continued until return of spontaneous circulation (ROSC) or a total of 60 minutes, if unsuccessful. SNPeCPR animals received 2 mg of SNP at minute 10 followed by 1 mg every 5 minutes until ROSC. Standard ACLS animals received 0.5 mg epinephrine every 5 minutes until ROSC. Primary endpoints were ROSC and 4-hour survival. Results All SNPeCPR animals (8/8) achieved sustained ROSC versus 2/8 standard ACLS animals within one hour of resuscitation (p=0.04). The 4-hour survival was significantly improved with SNPeCPR compared to standard ACLS, 7/8 versus 1/8 respectively, p=0.0019. Conclusion SNPeCPR significantly improved ROSC and 4-hour survival compared with standard ACLS CPR in a porcine model of prolonged ischemic, refractory VF cardiac arrest. PMID:27771299
Yannopoulos, Demetris; Bartos, Jason A; George, Stephen A; Sideris, George; Voicu, Sebastian; Oestreich, Brett; Matsuura, Timothy; Shekar, Kadambari; Rees, Jennifer; Aufderheide, Tom P
2017-01-01
Sodium nitroprusside (SNP) enhanced CPR (SNPeCPR) demonstrates increased vital organ blood flow and survival in multiple porcine models. We developed a new, coronary occlusion/ischemia model of prolonged resuscitation, mimicking the majority of out-of-hospital cardiac arrests presenting with shockable rhythms. SNPeCPR will increase short term (4-h) survival compared to standard 2015 Advanced Cardiac Life Support (ACLS) guidelines in an ischemic refractory ventricular fibrillation (VF), prolonged CPR model. Sixteen anesthetized pigs had the ostial left anterior descending artery occluded leading to ischemic VF arrest. VF was untreated for 5min. Basic life support was performed for 10min. At minute 10 (EMS arrival), animals received either SNPeCPR (n=8) or standard ACLS (n=8). Defibrillation (200J) occurred every 3min. CPR continued for a total of 45min, then the balloon was deflated simulating revascularization. CPR continued until return of spontaneous circulation (ROSC) or a total of 60min, if unsuccessful. SNPeCPR animals received 2mg of SNP at minute 10 followed by 1mg every 5min until ROSC. Standard ACLS animals received 0.5mg epinephrine every 5min until ROSC. Primary endpoints were ROSC and 4-h survival. All SNPeCPR animals (8/8) achieved sustained ROSC versus 2/8 standard ACLS animals within one hour of resuscitation (p=0.04). The 4-h survival was significantly improved with SNPeCPR compared to standard ACLS, 7/8 versus 1/8 respectively, p=0.0019. SNPeCPR significantly improved ROSC and 4-h survival compared with standard ACLS CPR in a porcine model of prolonged ischemic, refractory VF cardiac arrest. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Carrasco, H A; Vicuña, A V; Molina, C; Landaeta, A; Reynosa, J; Vicuña, N; Fuenmayor, A; López, F
1985-12-01
Low-dose (7 mg/kg per day) disopyramide administration to arrhythmic chagasic patients decreased the frequency of ventricular extrasystoles in 4 of 17 patients (24%) and suppressed most complex ventricular arrhythmias in 12 of 15 patients (80%). This assessment was made from 72-h continuous Holter monitoring recorded during the course of this double blind, placebo-controlled randomized crossover study. Seven patients (41%) complained of anticholinergic side effects, but no contractile or conduction system depression was seen. Amiodarone (200 mg) given on a single blind, placebo-controlled basis to 9 of these patients reduced the frequency of ventricular extrasystoles in 6 of 9 patients (67%) and suppressed complex ventricular ectopy in 6 of 7 patients (85%). One patient was unable to tolerate this drug (11%). Both drugs seemed less effective in controlling supraventricular arrhythmias, although disopyramide eliminated paroxysms of supraventricular tachycardia in 9 of 13 (69%) and amiodarone in all 6 patients with this arrhythmia. Amiodarone appears to be a better antiarrhythmic drug for chagasic patients, due to its greater effectiveness and lower incidence of side effects.
Shiraishi, Y; Yambe, T; Yoshizawa, M; Hashimoto, H; Yamada, A; Miura, H; Hashem, M; Kitano, T; Shiga, T; Homma, D
2012-01-01
Annuloplasty for functional mitral or tricuspid regurgitation has been made for surgical restoration of valvular diseases. However, these major techniques may sometimes be ineffective because of chamber dilation and valve tethering. We have been developing a sophisticated intelligent artificial papillary muscle (PM) by using an anisotropic shape memory alloy fiber for an alternative surgical reconstruction of the continuity of the mitral structural apparatus and the left ventricular myocardium. This study exhibited the mitral regurgitation with regard to the reduction in the PM tension quantitatively with an originally developed ventricular simulator using isolated goat hearts for the sophisticated artificial PM. Aortic and mitral valves with left ventricular free wall portions of isolated goat hearts (n=9) were secured on the elastic plastic membrane and statically pressurized, which led to valvular leaflet-papillary muscle positional change and central mitral regurgitation. PMs were connected to the load cell, and the relationship between the tension of regurgitation and PM tension were measured. Then we connected the left ventricular specimen model to our hydraulic ventricular simulator and achieved hemodynamic simulation with the controlled tension of PMs.
Ito, Tadahiko; Okubo, Tadashi
2002-12-01
A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.
Chabiniok, Radomir; Wang, Vicky Y; Hadjicharalambous, Myrianthi; Asner, Liya; Lee, Jack; Sermesant, Maxime; Kuhl, Ellen; Young, Alistair A; Moireau, Philippe; Nash, Martyn P; Chapelle, Dominique; Nordsletten, David A
2016-04-06
With heart and cardiovascular diseases continually challenging healthcare systems worldwide, translating basic research on cardiac (patho)physiology into clinical care is essential. Exacerbating this already extensive challenge is the complexity of the heart, relying on its hierarchical structure and function to maintain cardiovascular flow. Computational modelling has been proposed and actively pursued as a tool for accelerating research and translation. Allowing exploration of the relationships between physics, multiscale mechanisms and function, computational modelling provides a platform for improving our understanding of the heart. Further integration of experimental and clinical data through data assimilation and parameter estimation techniques is bringing computational models closer to use in routine clinical practice. This article reviews developments in computational cardiac modelling and how their integration with medical imaging data is providing new pathways for translational cardiac modelling.
Current applications of lasers in heart disease
NASA Astrophysics Data System (ADS)
Lee, Garrett; Chan, Ming C.; Mason, Dean T.
1993-03-01
Although the laser has been in existence for abut 30 years, its application in heart disease has only been examined in the past decade. Much attention has been given its exciting potential in treating coronary artery disease. Transmitted through a catheter comprised of one or more thin optical fibers which can be threaded nonsurgically into the coronary artery, the laser can ablate atherosclerotic plaque that obstructs the artery and diminishes blood flow to the myocardium. In clinical studies, the laser can treat some obstructive lesions that are not suitable for balloon angioplasty (i.e., long and diffuse lesions, very tight stenoses, ostial lesions, calcified lesions). In patients who failed balloon angioplasty due to severe dissection or abrupt closure, the laser may seal up the dissections and restore antegrade blood flow. In addition, the laser may have other applications and treatment modalities that are still under investigation. It may ablate ectopic ventricular foci, or terminate supraventricular tachyrhythmia by destroying the heart's abnormal conduction pathways. It can cut the hypertrophied septum that is associated with left ventricular outflow tract obstruction, or create a channel in the atrial septum as a palliative procedure in newborns with transposition of the great vessels. It may provide a wider orifice for blood flow within the heart in infants with pulmonary outflow obstruction and in adults with aortic valvular stenosis. It is also capable of fusing small thin-walled blood vessels together. Further, a more intriguing possibility is its use to bore several tiny channels in the myocardium to allow oxygenated blood from within the ventricular chamber to perfuse the ischemic heart tissue.
Vallecilla, Carolina; Khiabani, Reza H; Sandoval, Néstor; Fogel, Mark; Briceño, Juan Carlos; Yoganathan, Ajit P
2014-06-03
The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of high altitude exposure on hemodynamics and ventricular function of the BDG physiology is investigated. For this purpose, a mathematical approach based on a lumped parameter model was developed to model the BDG circulation. Catheterization data from 39 BDG patients at stabilized oxygen conditions was used to determine baseline flows and pressures for the model. The effect of high altitude exposure was modeled by increasing the pulmonary vascular resistance (PVR) and heart rate (HR) in increments up to 80% and 40%, respectively. The resulting differences in vascular flows, pressures and ventricular function parameters were analyzed. By simultaneously increasing PVR and HR, significant changes (p <0.05) were observed in cardiac index (11% increase at an 80% PVR and 40% HR increase) and pulmonary flow (26% decrease at an 80% PVR and 40% HR increase). Significant increase in mean systemic pressure (9%) was observed at 80% PVR (40% HR) increase. The results show that the poor ventricular function fails to overcome the increased preload and implied low oxygenation in BDG patients at higher altitudes, especially for those with high baseline PVRs. The presented mathematical model provides a framework to estimate the hemodynamic performance of BDG patients at different PVR increments. Copyright © 2014 Elsevier Ltd. All rights reserved.
Unusual mechanism of tricuspid regurgitation in ventricular septal defect.
Desai, Ravi V; Seghatol-Eslami, Frank; Nabavizadeh, Fatemeh; Lloyd, Steven G
2011-02-01
A 37-year-old woman was diagnosed to have a small ventricular septal defect (VSD) with high velocity tricuspid regurgitation (TR) that was attributed to atrio-VSD (Gerbode). Cardiac MR revealed a small subaortic VSD in the membranous portion of the interventricular septum. The atrioventricular portion was intact. Cardiac MR clearly showed flow jet through the VSD, impinging on the anterior tricuspid leaflet during systole, and bouncing back into the right atrium as TR. This ricochet mechanism of TR in VSD may be misinterpreted as Gerbode defect or as evidence of pulmonary hypertension. © 2011, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Bulusu, Kartik V.; Plesniak, Michael W.
2013-11-01
Systolic and diastolic blood pressures, pulse pressures, and left ventricular hypertrophy contribute to cardiovascular risks. Increase of arterial stiffness due to aging and hypertension is an important factor in cardiovascular, chronic kidney and end-stage-renal-diseases. Pulse wave analysis (PWA) based on arterial pressure wave characteristics, is well established in clinical practice for evaluation of arterial distensibility and hypertension. The objective of our exploratory study in a rigid 180-degree curved artery model was to evaluate arterial pressure waveforms. Bend upstream conditions were measured using a two-component, two-dimensional, particle image velocimeter (2C-2D PIV). An ultrasonic transit-time flow meter and a catheter with a MEMS-based solid state pressure sensor, capable of measuring up to 20 harmonics of the observed pressure waveform, monitored flow conditions downstream of the bend. Our novel continuous wavelet transform algorithm (PIVlet 1.2), in addition to detecting coherent secondary flow structures is used to evaluate arterial pulse wave characteristics subjected to physiological and non-physiological inflows. Results of this study will elucidate the utility of wavelet transforms in arterial function evaluation and pulse wave speed. Supported by NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.
Recurrent Ventricular Tachycardia in Medium-Chain Acyl-Coenzyme A Dehydrogenase Deficiency.
Bala, P; Ferdinandusse, S; Olpin, S E; Chetcuti, P; Morris, A A M
2016-01-01
We report a baby with medium-chain acyl-coenzyme A dehydrogenase (MCAD) deficiency who presented on day 2 with poor feeding and lethargy. She was floppy with hypoglycaemia (1.8 mmol/l) and hyperammonaemia (182 μmol/l). Despite correction of these and a continuous intravenous infusion of glucose at 4.5-6.2 mg/kg/min, she developed generalised tonic clonic seizures on day 3. She also suffered two episodes of pulseless ventricular tachycardia, from which she was resuscitated successfully. Unfortunately, she died on day 5, following a third episode of pulseless ventricular tachycardia. Arrhythmias are generally thought to be rarer in MCAD deficiency than in disorders of long-chain fatty acid oxidation. This is, however, the sixth report of ventricular tachyarrhythmias in MCAD deficiency. Five of these involved neonates and it may be that patients with MCAD deficiency are particularly prone to ventricular arrhythmias in the newborn period. Three of the patients (including ours) had normal blood glucose concentrations at the time of the arrhythmias and had been receiving intravenous glucose for many hours. These cases suggest that arrhythmias can be induced by medium-chain acylcarnitines or other metabolites accumulating in MCAD deficiency. Ventricular tachyarrhythmias can occur in MCAD deficiency, especially in neonates.
Diagnostic value of isoproterenol testing in arrhythmogenic right ventricular cardiomyopathy.
Denis, Arnaud; Sacher, Frédéric; Derval, Nicolas; Lim, Han S; Cochet, Hubert; Shah, Ashok J; Daly, Matthew; Pillois, Xavier; Ramoul, Khaled; Komatsu, Yuki; Zemmoura, Adlane; Amraoui, Sana; Ritter, Philippe; Ploux, Sylvain; Bordachar, Pierre; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel
2014-08-01
Although the Task Force Criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC) have recently been updated, the diagnosis remains challenging in the early stages. The aim of this study was to evaluate the diagnostic value of β-adrenergic stimulation in ARVC. We evaluated 412 consecutive patients (213 men, age 41.5±16 years) referred for premature ventricular contractions evaluation or suspected ARVC. Isoproterenol testing was performed with continuous infusion of isoproterenol (45 μg/min) for 3 minutes. It was considered positive if there were either (1) polymorphic premature ventricular contractions with ≥1 couplet or (2) sustained or nonsustained ventricular tachycardia with left bundle branch block excluding right ventricular outflow tract ventricular tachycardia. ARVC was diagnosed in 35 patients at initial evaluation (23 men, aged 42±15 years). Isoproterenol testing was positive in 32 of 35 (91.4%) patients with ARVC and in 42 of 377 (11.1%) patients without ARVC (P<0.0001). Sensitivity, specificity, positive, and negative predictive values of isoproterenol testing to diagnose ARVC were 91.4%, 88.9%, 43.2%, and 99.1%, respectively. During a mean follow-up period of 5.6±4.4 years, 6 additional patients met diagnostic criteria for ARVC. Importantly, initial isoproterenol testing was positive in 6 of 6 (100%) of these patients. Survival free from ARVC diagnosis was significantly lower in the positive isoproterenol group than in the negative isoproterenol group (P<0.0001, exact log-rank test). Ventricular arrhythmogenicity during isoproterenol testing is highly sensitive (sensitivity, 91.4%) for the diagnosis of ARVC, particularly in its early stages. © 2014 American Heart Association, Inc.
Hochwald, Ori; Jabr, Mohammad; Osiovich, Horacio; Miller, Steven P; McNamara, Patrick J; Lavoie, Pascal M
2014-05-01
To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3-4. LVCO was markedly reduced (mean ± SD 126 ± 38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88 ± 27 mL/kg/min) such that SVC flow represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 ± 13 vs 123 ± 17 beats/min; P < .001) compared with immediately postwarming in the context of myocardial dysfunction. Neonates with brain injury on magnetic resonance imaging had higher SVC flow prerewarming, compared with newborns without brain injury (P = .013). Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to-cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.
Balaras, Elias; Cha, K S; Griffith, Bartley P; Gammie, James S
2009-03-01
Aortic valve bypass surgery treats aortic valve stenosis with a valve-containing conduit that connects the left ventricular apex to the descending thoracic aorta. After aortic valve bypass, blood is ejected from the left ventricle via both the native stenotic aortic valve and the conduit. We performed computational modeling to determine the effects of aortic valve bypass on aortic and cerebral blood flow, as well as the effect of conduit size on relative blood flow through the conduit and the native valve. The interaction of blood flow with the vascular boundary was modeled using a hybrid Eurelian-Lagrangian formulation, where an unstructured Galerkin finite element method was coupled with an immersed boundary approach. Our model predicted native (stenotic) valve to conduit flow ratios of 45:55, 52:48, and 60:40 for conduits with diameters of 20, 16, and 10 mm, respectively. Mean gradients across the native aortic valve were calculated to be 12.5, 13.8, and 17.6 mm Hg, respectively. Post-aortic valve bypass cerebral blood flow was unchanged from preoperative aortic valve stenosis configurations and was constant across all conduit sizes. In all cases modeled, cerebral blood flow was completely supplied by blood ejected across the native aortic valve. An aortic valve bypass conduit as small as 10 mm results in excellent relief of left ventricular outflow tract obstruction in critical aortic valve stenosis. The presence of an aortic valve bypass conduit has no effect on cerebral blood flow. All blood flow to the brain occurs via antegrade flow across the native stenotic valve; this configuration may decrease the long-term risk of cerebral thromboembolism.
Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.
Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse
2014-10-01
High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Vortex shedding in bileaflet heart valve prostheses.
Gross, J M; Shermer, C D; Hwang, N H
1988-01-01
A dynamic study of two geometrically similar bileaflet heart valve prostheses (HVP) was performed using a physiologic mock circulatory flow loop. The HVPs studied were the 25 mm St. Jude Medical (SJM) and the 25 mm Carbomedics (CMI) in the aortic position and the 27 mm SJM and 27 mm CMI in the mitral position. All data were collected at a heart rate of 70 beats/min and a cardiac output of 5.0 L/min. Flow visualization was conducted in the transparent flow chambers of the pulsatile mock circulatory flow loop using a 15 mW He-Ne laser light source. A cylindrical lens and optics system converted the incident laser beam into a thin parallel light plane, and 420 microns tracer particles were suspended in the testing fluid to illuminate the flow field at selected planes. Frame-by-frame analysis of the 16 mm high-speed cine provides detailed phasic flow patterns in the vicinity of the HVP. A series of still photographs of flow patterns, taken at approximately 22.5 degrees phase intervals, are sequentially presented for each HVP. In the aortic position, a Karman-like vortex pattern appears downstream of the SJM at the end of the ejection phase. The CMI exhibits a rather symmetrical ejection flow pattern that turns into random motion immediately after the onset of ejection. In the mitral position, the SJM again exhibits a strong core flow during ventricular filling, whereas the CMI produces a more diffuse pattern during the same period. A pair of vortices shed from both the SJM and CMI are clearly visible toward the end of the ventricular filling phase. The vortex mechanisms are discussed in light of leaflet boundary layer formation.
Vorticity is a marker of diastolic ventricular interdependency in pulmonary hypertension
Browning, James; Schroeder, Joyce D.; Shandas, Robin; Kheyfets, Vitaly O.; Buckner, J. Kern; Hunter, Kendall S.; Hertzberg, Jean R.; Fenster, Brett E.
2016-01-01
Abstract Our objective was to determine whether left ventricular (LV) vorticity (ω), the local spinning motion of a fluid element, correlated with markers of ventricular interdependency in pulmonary hypertension (PH). Maladaptive ventricular interdependency is associated with interventricular septal shift, impaired LV performance, and poor outcomes in PH patients, yet the pathophysiologic mechanisms underlying fluid-structure interactions in ventricular interdependency are incompletely understood. Because conformational changes in chamber geometry affect blood flow formations and dynamics, LV ω may be a marker of LV-RV (right ventricular) interactions in PH. Echocardiography was performed for 13 PH patients and 10 controls for assessment of interdependency markers, including eccentricity index (EI), and biventricular diastolic dysfunction, including mitral valve (MV) and tricuspid valve (TV) early and late velocities (E and A, respectively) as well as MV septal and lateral early tissue Doppler velocities (e′). Same-day 4-dimensional cardiac magnetic resonance was performed for LV E (early)-wave ω measurement. LV E-wave ω was significantly decreased in PH patients (P = 0.008) and correlated with diastolic EI (Rho = −0.53, P = 0.009) as well as with markers of LV diastolic dysfunction, including MV E(Rho = 0.53, P = 0.011), E/A (Rho = 0.56, P = 0.007), septal e′ (Rho = 0.63, P = 0.001), and lateral e′ (Rho = 0.57, P = 0.007). Furthermore, LV E-wave ω was associated with indices of RV diastolic dysfunction, including TV e′ (Rho = 0.52, P = 0.012) and TV E/A (Rho = 0.53, P = 0.009). LV E-wave ω is decreased in PH and correlated with multiple echocardiographic markers of ventricular interdependency. LV ω may be a novel marker for fluid-tissue biomechanical interactions in LV-RV interdependency. PMID:27162613
Floroff, Catherine K; Rieger, Krista L; Veasey, Tara M; Strout, Sara E; DeNino, Walter F; Meadows, Holly B; Stroud, Martha R; Toole, John M; Heyward, Dawn P; Brisco-Bacik, Meredith A; Cook, Jennifer L; Lazarchick, John; Uber, Walter E
Pump thrombosis (PT) is a severe complication of left ventricular assist device (LVAD) support. This study evaluated PT and bleeding after LVAD placement in patients responsive to a standard aspirin dose of 81 mg using platelet inhibition monitoring compared with initial nonresponders who were then titrated upward to achieve therapeutic response. Patients ≥ 18 years of age with initial placement of HeartMate II LVAD at our institution and at least one VerifyNow Aspirin test performed during initial hospitalization were included. The primary endpoints were bleeding and PT compared between initial aspirin responders and nonresponders. Of 85 patients, 19 (22%) were nonresponsive to initial aspirin therapy. Responders and nonresponders showed similar survival (p = 0.082), freedom from suspected/confirmed PT (p = 0.941), confirmed PT (p = 0.273), bleeding (p = 0.401), and incidence rates in PT and bleeding. Among the initial responders (<500 vs. 500-549 aspirin reaction units), there were no significant differences in survival (p = 0.177), freedom from suspected/confirmed PT (p = 0.542), confirmed PT (p = 0.159), bleeding (p = 0.879), and incidence of PT and bleeding. Platelet function testing may detect resistance to standard aspirin regimens used in LVAD patients. Dose escalation in initially nonresponsive patients to achieve responsiveness may confer a similar PT risk to patients initially responsive to standard aspirin dosing without increased bleeding risk.
Kitano, Tomoya; Iwasaki, Kiyotaka
The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.
Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.
Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A
2018-04-30
Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.
Regional myocardial shape and dimensions of the working isolated canine left ventricle
NASA Technical Reports Server (NTRS)
Ritman, E.; Tsuiki, K.; Donald, D.; Wood, E. H.
1975-01-01
Angiographic experiments were performed on isolated canine left ventricle preparations using donor dog to supply blood to the coronary circulation via a rotary pump to control coronary flow. The angiographic record was transferred from video tape to video disk for detailed uninterrupted sequential analysis at a frequency of 60 fields/sec. It is shown that the use of a biplane X-ray technique and a metabolically supported isolated canine left ventricle preparation provides an angiographically ideal means of measuring the mechanical dynamics of the myocardium while the intact left ventricular myocardial structure and electrical activation pattern retain most of the in situ ventricular characteristics. In particular, biplane X-ray angiography of the left ventricle can provide estimates of total ventricular function such as ejection fraction, stroke volume, and myocardial mass correct to within 15% under the angiographically ideal conditions of the preparation.
Traumatic ventricular septal defect following a stab wound to the chest.
Ito, Hideki; Saito, Shunei; Miyahara, Ken; Takemura, Haruki; Sawaki, Sadanari; Matsuura, Akio
2009-03-01
A 51-year-old man who had been suffering from depression stabbed himself in the chest with an ice pick. At presentation, an ice pick lodged in the left fifth intercostal space was moving synchronously with his heartbeat. Echocardiography revealed that the tip was penetrating the anterior wall of the right ventricle. Because the patient was tamponading, an emergency operation was carried out. The ice pick was removed following the establishment of a cardiopulmonary bypass and pericardiotomy. The perforation of the right ventricle was closed with a pledget-reinforced mattress stitch. On postoperative day 12, a holosystolic murmur was detected on auscultation. Transthoracic echocardiography revealed a ventricular septal defect 5 mm in diameter located near the apex. The pulmonary-tosystemic flow ratio was 1.1 by echocardiographic measurement. No sign of heart failure was present. Although it was agreed to manage the ventricular septal defect conservatively, careful echocardiographic follow-up is mandatory.
Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles; Sherrid, Mark V
2014-11-11
The hydrodynamic cause of systolic anterior motion of the mitral valve (SAM) is unresolved. This study hypothesized that echocardiographic vector flow mapping, a new echocardiographic technique, would provide insights into the cause of early SAM in obstructive hypertrophic cardiomyopathy (HCM). We analyzed the spatial relationship of left ventricular (LV) flow and the mitral valve leaflets (MVL) on 3-chamber vector flow mapping frames, and performed mitral valve measurements on 2-dimensional frames in patients with obstructive and nonobstructive HCM and in normal patients. We compared 82 patients (22 obstructive HCM, 23 nonobstructive HCM, and 37 normal) by measuring 164 LV pre- and post-SAM velocity vector flow maps, 82 maximum isovolumic vortices, and 328 2-dimensional frames. We observed color flow and velocity vector flow posterior to the MVL impacting them in the early systolic frames of 95% of obstructive HCM, 22% of nonobstructive HCM, and 11% of normal patients (p < 0.001). In both pre- and post-SAM frames, we measured a high angle of attack >60° of local vector flow onto the posterior surface of the leaflets whether the flow was ejection (59%) or the early systolic isovolumic vortex (41%). Ricochet of vector flow, rebounding off the leaflet into the cul-de-sac, was noted in 82% of the obstructed HCM, 9% of nonobstructive HCM, and none (0%) of the control patients (p < 0.001). Flow velocities in the LV outflow tract on the pre-SAM frame 1 and 2 mm from the tip of the anterior leaflet were low: 39 and 43 cm/s, respectively. Early systolic flow impacts the posterior surfaces of protruding MVL initiating SAM in obstructive HCM. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Zhou, Shengmei; Tan, Alex Y.; Paz, Offir; Ogawa, Masahiro; Chou, Chung-Chuan; Hayashi, Hideki; Nihei, Motoki; Fishbein, Michael C.; Chen, Lan S.; Lin, Shien-Fong; Chen, Peng-Sheng
2009-01-01
Background Beta3-adrenergic receptor (beta3-AR) stimulation inhibits cardiac contractility. Objective To test the hypothesis that beta3-AR stimulation is antiarrhythmic. Methods We implanted a radiotransmitter for continuous ECG monitoring in 18 dogs with a tendency for high incidence of spontaneous ventricular tachycardia (VT). Ten of 18 had subcutaneous continuous BRL37344 (beta3-AR agonist) infusion (experimental group) for 1 month. The other dogs were controls. Western blotting studies were performed on tissues sampled from the noninfarcted left ventricular free wall of all dogs that survived the 60-day follow up period. Results Phase-2 VT appeared significantly later in the experimental group than in the control group (p<0.05). The number of VT episodes in the experimental group was significantly lower than control during both the first month (0.5 ± 0.95 episode/d vs. 2.6 ± 2.3 episode/d) and the second month (0.2 ± 0.2 episode/d vs. 1.2 ± 1.1 episode/d, p<0.05 for both). The experimental group had shorter QTc than control (p<0.002). The experimental group had decreased protein levels for sodium calcium exchanger and dihydropyridine receptor, increased beta3-AR expression, without changes in beta1-AR, beta2-AR. The average heart weight and the left ventricular free wall thickness in the experimental group (226 ± 17 g and 15.1 ± 1.2 mm, respectively) was significantly lower than control (265 ± 21 g and 17.4 ± 2.5 mm, respectively, p<0.05 for both). There was no difference in the incidences of sudden cardiac death (SCD) in these two groups of dogs. Conclusion Beta3-AR stimulation significantly reduces the occurrence of ventricular tachycardia. PMID:18242556
Schmack, Bastian; Weymann, Alexander; Popov, Aron-Frederik; Patil, Nikhil Prakash; Sabashnikov, Anton; Kremer, Jamila; Farag, Mina; Brcic, Andreas; Lichtenstern, Christoph; Karck, Matthias; Ruhparwar, Arjang
2016-05-05
Right ventricular failure (RVF) is an unfortunate complication that continues to limit outcomes following durable left ventricular assist device (LVAD) implantation. Despite several 'RVF risk scores' having been proposed, preoperative prediction of post-LVAD RVF remains a guesstimate at best. Current strategies for institution of temporary RVAD support are invasive, necessitate additional re-thoracotomy, restrict postoperative mobilization, and/or entail prolonged retention of prosthetic material in-situ. The authors propose a novel surgical strategy comprising simultaneous implantation of a permanent LVAD and percutaneous TandemHeart® plus ProtekDuo® to provide temporary RVAD support and preempt RVF in patients with impaired RV function.
Wang, Jake X; Smith, Joshua R; Bonde, Pramod
2014-04-01
Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Singh, M. P.; Bentall, H. H.; Oakley, C. M.
1970-01-01
Successful surgical correction of the complex anomaly of interruption of the aortic arch and intracardiac ventricular septal defect is reported. The patient was a boy 5 years old when he first came under treatment. The total correction was performed in two stages. At the first operation, at the age of 7 years, continuity of the aortic arch was achieved by insertion of a Teflon graft, employing left heart bypass. The ventricular septal defect was closed at the age of 13 years on total cardiopulmonary bypass. Two and half years after the total correction the boy is alive and well. The difficulties in diagnosing the condition are discussed. The role of left heart bypass is emphasized. Images PMID:5489187
Galal, Mohammed Omar; Arfi, Muhammed Amin; Nicole, Sekarski; Payot, Maurice; Hussain, Arif; Qureshi, Shakeel
2005-11-01
A 12-year-old boy reported in outpatient department with history of shortness of breath and dyspnoea on moderate exertion. Physical examination was significant for bounding pulses and for a continuous murmur III/VI, best heard at the left upper sternal border. Echocardiography confirmed a large patent arterial duct with shortening fraction of 33%. He underwent successful transcatheter closure of the patent arterial, using Amplatzer duct occluder 12/10. Few hours later echocardiography revealed an unexpected, yet important depression of left ventricular systolic function with shortening fraction decreasing to 24% and then two weeks later decreasing further to 20%. At a follow-up after four months, he had improved clinically but left ventricular dysfunction still persisted with shortening fraction of 24%.
Zhou, Bin-Yu; Xie, Ming-Xing; Wang, Jing; Wang, Xin-Fang; Lv, Qing; Liu, Man-Wei; Kong, Shuang-Shuang; Zhang, Ping-Yu; Liu, Jin-Feng
2017-01-01
Abstract Intraventricular hydrodynamics plays an important role in evaluating cardiac function. Relationship between diastolic vortex and left ventricular (LV) filling is still rarely elucidated. The aim of this study was to evaluate the evolution of vortex during diastole in hyperthyroidism (HT) and explore the alteration of hydromechanics characteristics with sensitive indexes. Forty-three patients diagnosed with HT were classified into 2 groups according to whether myocardial damage existed: simple hyperthyroid group (HT1, n = 21) and thyrotoxic cardiomyopathy (HT2, n = 22). Twenty-seven age- and gender-matched healthy volunteers were enrolled as the control group. Offline vector flow mapping (VFM model) was used to analyze the LV diastolic blood flow patterns and fluid dynamics. Hemodynamic parameters, vortex area (A), circulation (C), and intraventricular pressure gradient (ΔP), in different diastolic phases (early, mid, and late) were calculated and analyzed. HT2, with a lower E/A ratio and left ventricular ejection fraction (LVEF), had a larger left atrium diameter (LAD) compared with those of the control group and HT1 (P < .05). Compared with the control group, the vortex size and strength, intraventricular pressure gradient during early and mid-diastole were higher in HT1 and lower in HT2 (P < .05). And in late diastole, the vortex size and strength, intraventricular pressure gradient of HT2 became higher than those of the control group (P < .05). Good correlation could be found between CE and E/A (P < .05), CM and ΔPM (P < .01), CL and FT3 (P < .05). VFM is proven practical for detecting the relationship between the changes of left ventricular diastolic vortex and the abnormal left ventricular filling. PMID:28445281
NASA Technical Reports Server (NTRS)
Qin, J. X.; Jones, M.; Shiota, T.; Greenberg, N. L.; Tsujino, H.; Firstenberg, M. S.; Gupta, P. C.; Zetts, A. D.; Xu, Y.; Ping Sun, J.;
2000-01-01
OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.
Zhou, Bin-Yu; Xie, Ming-Xing; Wang, Jing; Wang, Xin-Fang; Lv, Qing; Liu, Man-Wei; Kong, Shuang-Shuang; Zhang, Ping-Yu; Liu, Jin-Feng
2017-04-01
Intraventricular hydrodynamics plays an important role in evaluating cardiac function. Relationship between diastolic vortex and left ventricular (LV) filling is still rarely elucidated. The aim of this study was to evaluate the evolution of vortex during diastole in hyperthyroidism (HT) and explore the alteration of hydromechanics characteristics with sensitive indexes.Forty-three patients diagnosed with HT were classified into 2 groups according to whether myocardial damage existed: simple hyperthyroid group (HT1, n = 21) and thyrotoxic cardiomyopathy (HT2, n = 22). Twenty-seven age- and gender-matched healthy volunteers were enrolled as the control group. Offline vector flow mapping (VFM model) was used to analyze the LV diastolic blood flow patterns and fluid dynamics. Hemodynamic parameters, vortex area (A), circulation (C), and intraventricular pressure gradient (ΔP), in different diastolic phases (early, mid, and late) were calculated and analyzed.HT2, with a lower E/A ratio and left ventricular ejection fraction (LVEF), had a larger left atrium diameter (LAD) compared with those of the control group and HT1 (P < .05). Compared with the control group, the vortex size and strength, intraventricular pressure gradient during early and mid-diastole were higher in HT1 and lower in HT2 (P < .05). And in late diastole, the vortex size and strength, intraventricular pressure gradient of HT2 became higher than those of the control group (P < .05). Good correlation could be found between CE and E/A (P < .05), CM and ΔPM (P < .01), CL and FT3 (P < .05).VFM is proven practical for detecting the relationship between the changes of left ventricular diastolic vortex and the abnormal left ventricular filling.
Swift, Andrew J.; Wild, Jim M.; Nagle, Scott K.; Roldán-Alzate, Alejandro; François, Christopher J.; Fain, Sean; Johnson, Kevin; Capener, Dave; van Beek, Edwin J. R.; Kiely, David G.; Wang, Kang; Schiebler, Mark L.
2014-01-01
Pulmonary hypertension (PH) is a condition of varied aetiology, commonly associated with a poor clinical outcome. Patients are categorised on the basis of pathophysiological, clinical, radiological and therapeutic similarities. Pulmonary arterial hypertension (PAH) is often diagnosed late in its disease course with outcome dependent on aetiology, disease severity and response to treatment. Recent advances in quantitative MR imaging allow for a better initial characterization and measurement of the morphologic and flow related changes that accompany the response of the heart-lung axis to prolonged elevation of pulmonary arterial pressure and resistance and provide a reproducible, comprehensive and non-invasive means of assessing the course of the disease and response to treatment. Typical features of pulmonary arterial hypertension (PAH) occur primarily as a result of increased pulmonary vascular resistance and resultant increased RV afterload. Several MRI derived diagnostic markers have emerged, such as ventricular mass index (VMI), interventricular septal configuration and average pulmonary artery velocity having reported diagnostic accuracy similar to Doppler echocardiography. Furthermore, prognostic markers have been identified with independent predictive value for identification of treatment failure. Such markers include: large right ventricular end-diastolic volume index (RVEDVI), low left ventricular end diastolic volume index (LVEDVI), low right ventricular ejection fraction (RVEF) and relative area change of the pulmonary trunk. MRI is ideally suited to longitudinal follow-up of patients with PAH due to its non-invasive nature, high reproducibility and has the advantage over other biomarkers in PAH due to its sensitivity to change in morphological, functional and flow related parameters. Further study the role of MR imaging as a biomarker in the clinical environment is warranted. PMID:24552882
Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.
Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J
2016-06-01
Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.
Atrial and ventricular function after cardioversion of atrial fibrillation.
Xiong, C.; Sonnhag, C.; Nylander, E.; Wranne, B.
1995-01-01
OBJECTIVE--Previous studies on atrial recovery after cardioversion of atrial fibrillation have not taken into account new knowledge about the pathophysiology of transmitral and transtricuspid flow velocity patterns. It is possible to shed further light on this problem if atrioventricular inflow velocity, venous filling pattern, and atrioventricular annulus motion are recorded and interpreted together. DESIGN--Prospective examinations of mitral and tricuspid transvalvar flow velocities, superior caval and pulmonary venous filling, and mitral and tricuspid annulus motion were recorded using Doppler echocardiography. Examinations were performed before and 24 hours, 1 month, and 20 months after cardioversion. SETTING--Tertiary referral centre for cardiac disease with facilities for invasive and non-invasive investigation. PATIENTS--16 patients undergoing cardioversion of atrial fibrillation in whom sinus rhythm had persisted for 24 hours or more. RESULTS--Before conversion there was no identifiable A wave in transvalvar flow recordings. The total motion of the tricuspid and mitral annulus was subnormal and there was no identifiable atrial component. Venous flow patterns in general showed a low systolic velocity. After conversion, A waves and atrial components were seen in all patients and increased significantly (P < 0.01) with time. There was a similar time course for the amplitude of annulus atrial components, an increased systolic component of venous inflow, an increased A wave velocity, and a decreased E/A ratio of the transvalvar velocity curves. The ventricular component of annulus motion was unchanged. Changes in general occurred earlier on the right side than the left. CONCLUSIONS--This study indicates that, in addition to the previously known electromechanical dissociation of atrial recovery that exists after cardioversion of atrial fibrillation, there may also be a transient deterioration of ventricular function modulating the transvalvar inflow velocity recordings. Function on the right side generally becomes normal earlier than on the left. Integration of information from transvalvar inflow curves, annulus motion, and venous filling patterns gives additional insight into cardiac function. PMID:7547019
Mulloy, Daniel P.; Bhamidipati, Castigliano M.; Stone, Matthew L.; Ailawadi, Gorav; Kron, Irving L.; Kern, John A.
2012-01-01
Objectives Orthotopic heart transplantation is the standard of care for end-stage heart disease. Left ventricular assist device implantation offers an alternative treatment approach. Left ventricular assist device practice has changed dramatically since the 2008 Food and Drug Administration approval of the HeartMate II (Thoratec, Pleasanton, Calif), but at what societal cost? The present study examined the cost and efficacy of both treatments over time. Methods All patients who underwent either orthotopic heart transplantation (n = 9369) or placement of an implantable left ventricular assist device (n = 6414) from 2005 to 2009 in the Nationwide Inpatient Sample were selected. The trends in treatment use, mortality, and cost were analyzed. Results The incidence of orthotopic heart transplantation increased marginally within a 5-year period. In contrast, the annual left ventricular assist device implantation rates nearly tripled. In-hospital mortality from left ventricular assist device implantation decreased precipitously, from 42% to 17%. In-hospital mortality for orthotopic heart transplantation remained relatively stable (range, 3.8%–6.5%). The mean cost per patient increased for both orthotopic heart transplantation and left ventricular assist device placement (40% and 17%, respectively). With the observed increase in both device usage and cost per patient, the cumulative Left ventricular assist device cost increased 232% within 5 years (from $143 million to $479 million). By 2009, Medicare and Medicaid were the primary payers for nearly one half of all patients (orthotopic heart transplantation, 45%; left ventricular assist device, 51%). Conclusions Since Food and Drug Administration approval of the HeartMate II, mortality after left ventricular assist device implantation has decreased rapidly, yet has remained greater than that after orthotopic heart transplantation. The left ventricular assist device costs have continued to increase and have been significantly greater than those for orthotopic heart transplantation. Because of the evolving healthcare economics climate, with increasing emphasis on the costs and comparative effectiveness, a concerted effort at LVAD cost containment and judicious usage is essential to preserve the viability of this invaluable treatment. PMID:23246055
Atrial fibrillation management in a breeding stallion.
Heliczer, N; Mitchell, K; Lorello, O; Dauvillier, J; Burger, D; Schwarzwald, C C; Navas de Solis, C
2017-06-01
A 20-year-old warmblood breeding stallion presented to a University practice for semen collection and evaluation was incidentally diagnosed with atrial fibrillation (AF). Electrocardiogram recordings during breeding revealed inappropriately rapid tachycardia and occasional ventricular premature depolarizations/aberrant ventricular conduction. Transvenous electrical cardioversion was performed. After successful cardioversion the horse displayed supraventricular ectopy and atrial contractile dysfunction and was administered sotalol hydrochloride in an attempt to decrease the risk of AF recurrence. Supraventricular ectopy and echocardiographic evidence of atrial dysfunction gradually improved and normalized over 6 months. No direct adverse effects of the chronic anti-arrhythmic treatment were observed and libido and semen quality were unaffected. AF recurred 6 months after cardioversion and sotalol therapy was continued to control the ventricular ectopy/aberrant ventricular conduction during semen collection. Considerations regarding pathologic arrhythmias and inappropriately high heart rates in breeding stallions with AF may be similar to those in riding horses. Sotalol hydrochloride was a safe anti-arrhythmic drug in the management of this case. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Reiber, J. H. C.
1976-01-01
To automate the data acquisition procedure, a real-time contour detection and data acquisition system for the left ventricular outline was developed using video techniques. The X-ray image of the contrast-filled left ventricle is stored for subsequent processing on film (cineangiogram), video tape or disc. The cineangiogram is converted into video format using a television camera. The video signal from either the TV camera, video tape or disc is the input signal to the system. The contour detection is based on a dynamic thresholding technique. Since the left ventricular outline is a smooth continuous function, for each contour side a narrow expectation window is defined in which the next borderpoint will be detected. A computer interface was designed and built for the online acquisition of the coordinates using a PDP-12 computer. The advantage of this system over other available systems is its potential for online, real-time acquisition of the left ventricular size and shape during angiocardiography.
Winter, R; Gudmundsson, P; Ericsson, G; Willenheimer, R
2001-06-01
To study the clinical value of the colour-M-mode slope of the early diastolic left ventricular filling phase (Vp) and the early diastolic downward M-mode slope of the left atrioventricular plane displacement (EDS), compared with diastolic function assessed by traditional Doppler evaluation. In 65 consecutive patients EDS and Vp were compared with a four-degree traditional diastolic function classification, based on pulsed Doppler assessment of the early to atrial transmitral flow ratio (E/A), the E-wave deceleration time (Edt), and the systolic to diastolic (S/D) pulmonary venous inflow ratio. Vp (P=0.006) and EDS (P=0.045) were related to traditional diastolic function (Kruskal--Wallis analysis). EDS showed a trend brake between the moderate and severe diastolic dysfunction groups by traditional Doppler evaluation. Vp and EDS correlated weakly in simple linear regression analysis (r=0.33). Vp and EDS discriminated poorly between normal and highly abnormal diastolic function. Vp and EDS were significantly related to diastolic function by traditional Doppler evaluation. They were, however, not useful as single parameters of left ventricular diastolic function due to a small difference between normal and highly abnormal values, allowing for little between-measurement variability. Consequently, these methods for the evaluation of left ventricular diastolic function do not add significantly to traditional Doppler evaluation.
Left ventricular hypertrophy diagnosed after a stroke: a case report.
Umeojiako, Wilfred Ifeanyi; Kanyal, Ritesh
2018-03-22
Stroke is a recognized clinical course of hypertrophic cardiomyopathy. This interesting case showed notable difference on the electrocardiogram of a patient 4 months prior to suffering a stroke and 10 days after suffering a stroke. The pre-stroke electrocardiogram showed atrial fibrillation with a narrow QRS complex, while the post-stroke electrocardiogram showed marked left ventricular hypertrophy. Left ventricular hypertrophy was diagnosed using the Sokolow-Lyon indices. The development of left ventricular hypertrophy a few days after suffering a stroke has not previously been reported. An 83-year-old white British woman with a background history of permanent atrial fibrillation, hypertension, and previous stroke attended the emergency department with a 2-day history of exertional dyspnea, and chest tightness. On examination, she had bibasal crepitations with a systolic murmur loudest at the apex. In-patient investigations include an electrocardiogram, blood tests, chest X-ray, contrast echocardiogram, coronary angiogram, and cardiovascular magnetic resonance imaging. An electrocardiogram showed atrial fibrillation, with inferolateral T wave inversion, and left ventricular hypertrophy. A chest X-ray showed features consistent with pulmonary edema. A contrast echocardiogram showed marked hypertrophy of the mid to apical left ventricle, appearance consistent with apical hypertrophic cardiomyopathy. Coronary angiography showed eccentric shelf-type plaque with non-flow-limiting stenosis in the left coronary artery main stem. Cardiovascular magnetic resonance imaging reported findings highly suggestive of apical hypertrophic cardiomyopathy. Our patient was treated and discharged on rivaroxaban, bisoprolol, and atorvastatin with a follow-up in the cardiomyopathy outpatient clinic. Electrocardiogram diagnosis of left ventricular hypertrophy led to the diagnosis of apical hypertrophic cardiomyopathy in this patient. Left ventricular hypertrophy was only evident a few days after our patient suffered a stroke. The underlying mechanisms responsible for this remain unclear. Furthermore, differential diagnosis of hypertrophic cardiomyopathy should be considered in people with electrocardiogram criteria for left ventricular hypertrophy. Cardiovascular magnetic resonance imaging is an important diagnostic tool in identifying causes of left ventricular hypertrophy. Family screening should be recommended in patients with new diagnosis of hypertrophic cardiomyopathy.
Kamphuis, Vivian P; Westenberg, Jos J M; van der Palen, Roel L F; van den Boogaard, Pieter J; van der Geest, Rob J; de Roos, Albert; Blom, Nico A; Roest, Arno A W; Elbaz, Mohammed S M
2018-01-05
The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. EL index was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, EL index and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. EL index showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless EL index , which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
Concomitant transcatheter aortic valve and left ventricular assist device implantation.
Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias
2013-01-01
Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.
Sjöberg, Pia; Heiberg, Einar; Wingren, Pär; Ramgren Johansson, Jens; Malm, Torsten; Arheden, Håkan; Liuba, Petru; Carlsson, Marcus
2017-04-01
Four-dimensional (4D) flow magnetic resonance imaging (MRI) enables quantification of kinetic energy (KE) in intraventricular blood flow. This provides a novel way to understand the cardiovascular physiology of the Fontan circulation. In this study, we aimed to quantify the KE in functional single ventricles. 4D flow MRI was acquired in eleven patients with Fontan circulation (median age 12 years, range 3-29) and eight healthy volunteers (median age 26 years, range 23-36). Follow-up MRI after surgical or percutaneous intervention was performed in 3 patients. Intraventricular KE was calculated throughout the cardiac cycle and indexed to stroke volume (SV). The systolic/diastolic ratio of KE in Fontan patients was similar to the ratio of the controls' left ventricle (LV) or right ventricle (RV) depending on the patients' ventricular morphology (Cohen´s κ = 1.0). Peak systolic KE/SV did not differ in patients compared to the LV in controls (0.016 ± 0.006 mJ/ml vs 0.020 ± 0.004 mJ/ml, p = 0.09). Peak diastolic KE/SV in Fontan patients was lower than in the LV of the control group (0.028 ± 0.010 mJ/ml vs 0.057 ± 0.011 mJ/ml, p < 0.0001). The KE during diastole showed a plateau in patients with aortopulmonary collaterals. This is to our knowledge the first study that quantifies the intraventricular KE of Fontan patients. KE is dependent on the morphology of the ventricle, and diastolic KE indexed to SV in patients is decreased compared to controls. The lower KE in Fontan patients may be a result of impaired ventricular filling.
Terada, Tomomasa; Mori, Kazuhiro; Inoue, Miki; Yasunobu, Hayabuchi
2016-11-01
Assessment of longitudinal left ventricular (LV) function is important for early detection of cardiac dysfunction. Although mitral annular plane systolic excursion (MAPSE) obtained by M-mode echocardiography offers a simple method for assessing longitudinal LV function, normal values of MAPSE for children change according to body size. To minimize the effects of body size, MAPSE was divided by LV long-axis length (MAPSE/L). MAPSE/L was measured in 210 healthy children from birth to 15 years of age and classified into five subgroups. MAPSE/L was then compared with 10 parameters in 136 children (age, heart rate, mean blood pressure, ejection fraction of the LV (EF), peak atrial flow velocity/peak early diastolic flow velocity of mitral flow, tissue Doppler velocity during systole (s') and early diastole (e'), E/e' ratio, Tei index, and global longitudinal strain (GLS) of the LV by the speckle tracking method). MAPSE/L was significantly lower in the neonate group than in the remaining four groups. MAPSE/L then increased with age to peak at 1-5 years and gradually decreased thereafter. In all cases beyond the neonatal period, MAPSE/L was more than 0.17. Among various parameters, GLS, age, EF, Tei index and s' were significantly associated with MAPSE/L in that order. In univariate analysis, GLS was most significantly associated with MAPSE/L (r=.56). We have established normal reference values for MPSE/L in healthy children. MAPSE/L is expected to offer a simple parameter to evaluate LV longitudinal systolic function during daily routine echocardiography in children. © 2016, Wiley Periodicals, Inc.
Choi, Young Joon; Constantino, Jason; Vedula, Vijay; Trayanova, Natalia; Mittal, Rajat
2015-01-01
A methodology for the simulation of heart function that combines an MRI-based model of cardiac electromechanics (CE) with a Navier–Stokes-based hemodynamics model is presented. The CE model consists of two coupled components that simulate the electrical and the mechanical functions of the heart. Accurate representations of ventricular geometry and fiber orientations are constructed from the structural magnetic resonance and the diffusion tensor MR images, respectively. The deformation of the ventricle obtained from the electromechanical model serves as input to the hemodynamics model in this one-way coupled approach via imposed kinematic wall velocity boundary conditions and at the same time, governs the blood flow into and out of the ventricular volume. The time-dependent endocardial surfaces are registered using a diffeomorphic mapping algorithm, while the intraventricular blood flow patterns are simulated using a sharp-interface immersed boundary method-based flow solver. The utility of the combined heart-function model is demonstrated by comparing the hemodynamic characteristics of a normal canine heart beating in sinus rhythm against that of the dyssynchronously beating failing heart. We also discuss the potential of coupled CE and hemodynamics models for various clinical applications. PMID:26442254
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
[Initial experience with a new blood pump].
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-12-01
A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.
Rotacor: a new rotary blood pump.
Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A
1990-01-01
A new rotary blood pump was tested in calves for 6 hr. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotates on an eccentric shaft in a trochoidal path, thus creating a gap seal. The pump is driven by a water-cooled DC motor. For right ventricular assist, a cannula was inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assist. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 3 L at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hr, when it started to chop again; after 6 hr it was 16 mg/dl. From these preliminary results it is concluded that this new type of blood pump may be suitable as a circulatory assist device.
Taser X26 discharges in swine: ventricular rhythm capture is dependent on discharge vector.
Valentino, Daniel J; Walter, Robert J; Dennis, Andrew J; Margeta, Bosko; Starr, Frederic; Nagy, Kimberly K; Bokhari, Faran; Wiley, Dorion E; Joseph, Kimberly T; Roberts, Roxanne R
2008-12-01
Data from our previous studies indicate that Taser X26 stun devices can acutely alter cardiac function in swine. We hypothesized that most transcardiac discharge vectors would capture ventricular rhythm, but that other vectors, not traversing the heart, would fail to capture the ventricular rhythm. Using an Institutional Animal Care and Use Committee (IACUC) approved protocol, four Yorkshire pigs (25-36 kg) were anesthetized, paralyzed with succinylcholine (2 mg/kg), and then exposed to 10 second discharges from a police-issue Taser X26. For most discharges, the barbed darts were pushed manually into the skin to their full depth (12 mm) and were arranged in either transcardiac (such that a straight line connecting the darts would cross the region of the heart) or non-transcardiac vectors. A total of 11 different vectors and 22 discharge conditions were studied. For each vector, by simply rotating the cartridge 180-degrees in the gun, the primary current-emitting dart was changed and the direction of current flow during the discharge was reversed without physically moving the darts. Echocardiography and electrocardiograms (ECGs) were performed before, during, and after all discharges. p values < 0.05 were considered significant. ECGs were unreadable during the discharges because of electrical interference, but echocardiography images clearly demonstrated that ventricular rhythm was captured immediately in 52.5% (31 of 59) of the discharges on the ventral surface of the animal. In each of these cases, capture of the ventricular rhythm with rapid ventricular contractions consistent with ventricular tachycardia (VT) or flutter was seen throughout the discharge. A total of 27 discharges were administered with transcardiac vectors and ventricular capture occurred in 23 of these discharges (85.2% capture rate). A total of 32 non-transcardiac discharges were administered ventrally and capture was seen in only eight of these (25% capture rate). Ventricular fibrillation (VF) was seen with two vectors, both of which were transcardiac. In the remaining animals, VT occurred postdischarge until sinus rhythm was regained spontaneously. For most transcardiac vectors, Taser X26 caused immediate ventricular rhythm capture. This usually reverted spontaneously to sinus rhythm but potentially fatal VF was seen with two vectors. For some non-transcardiac vectors, capture was also seen but with a significantly (p < 0.0001) decreased incidence.
Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.
Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha
Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.
Malliaras, Konstantinos; Charitos, Efstratios; Diakos, Nikolaos; Pozios, Iraklis; Papalois, Apostolos; Terrovitis, John; Nanas, John
2014-12-01
We investigated the effects of intra-aortic balloon pump (IABP) counterpulsation on left ventricular (LV) contractility, relaxation, and energy consumption and probed the underlying physiologic mechanisms in 12 farm pigs, using an ischemia-reperfusion model of acute heart failure. During both ischemia and reperfusion, IABP support unloaded the LV, decreased LV energy consumption (pressure-volume area, stroke work), and concurrently improved LV mechanical performance (ejection fraction, stroke volume, cardiac output). During reperfusion exclusively, IABP also improved LV relaxation (tau) and contractility (Emax, PRSW). The beneficial effects of IABP support on LV relaxation and contractility correlated with IABP-induced augmentation of coronary blood flow. In conclusion, we find that during both ischemia and reperfusion, IABP support optimizes LV energetic performance (decreases energy consumption and concurrently improves mechanical performance) by LV unloading. During reperfusion exclusively, IABP support also improves LV contractility and active relaxation, possibly due to a synergistic effect of unloading and augmentation of coronary blood flow.
De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco
2014-02-01
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Asphyxia-activated corticocardiac signaling accelerates onset of cardiac arrest.
Li, Duan; Mabrouk, Omar S; Liu, Tiecheng; Tian, Fangyun; Xu, Gang; Rengifo, Santiago; Choi, Sarah J; Mathur, Abhay; Crooks, Charles P; Kennedy, Robert T; Wang, Michael M; Ghanbari, Hamid; Borjigin, Jimo
2015-04-21
The mechanism by which the healthy heart and brain die rapidly in the absence of oxygen is not well understood. We performed continuous electrocardiography and electroencephalography in rats undergoing experimental asphyxia and analyzed cortical release of core neurotransmitters, changes in brain and heart electrical activity, and brain-heart connectivity. Asphyxia stimulates a robust and sustained increase of functional and effective cortical connectivity, an immediate increase in cortical release of a large set of neurotransmitters, and a delayed activation of corticocardiac functional and effective connectivity that persists until the onset of ventricular fibrillation. Blocking the brain's autonomic outflow significantly delayed terminal ventricular fibrillation and lengthened the duration of detectable cortical activities despite the continued absence of oxygen. These results demonstrate that asphyxia activates a brainstorm, which accelerates premature death of the heart and the brain.
Diastolic function of the nonfilling human left ventricle.
Paulus, W J; Vantrimpont, P J; Rousseau, M F
1992-12-01
To investigate an early-diastolic left ventricular suction effect in humans, tip-micromanometer left ventricular pressure recordings were obtained in patients with mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon, which fits tightly in the mitral orifice. When mitral inflow was impeded in anesthetized dogs, left ventricular pressure decayed to a negative asymptote value. This negative asymptote value was consistent with an early diastolic suction effect. Tip-micromanometer left ventricular pressure recordings were obtained in 23 patients with symptomatic mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon. The left ventricular diastolic asymptote pressure (P(asy)) was determined in 47 nonfilling beats with a sufficiently long (greater than 200 ms) diastolic time interval (that is, the interval from minimal first derivative of left ventricular pressure to left ventricular end-diastolic pressure) and equaled 2 +/- 3 mm Hg for beats with normal intraventricular conduction and 3 +/- 2 mm Hg for beats with aberrant intraventricular conduction. Left ventricular angiography was performed in five patients during the first inflation of the Inoue balloon at the time of complete balloon expansion. Left ventricular end-diastolic volume of the nonfilling beats averaged 38 +/- 14 ml and was comparable to the left ventricular end-systolic volume (39 +/- 19 ml) measured during baseline angiography before mitral valvuloplasty. Time constants of left ventricular pressure decay were calculated on 21 nonfilling beats with a diastolic time interval greater than 200 ms, normal intraventricular conduction and peak left ventricular pressure greater than 50 mm Hg. Time constants (T0 and TBF) derived from an exponential curve fit with zero asymptote pressure and with a best-fit asymptote pressure were compared with a time constant (T(asy)) derived from an exponential curve fit with the measured diastolic left ventricular asymptote pressure. The value for T(asy) (37 +/- 9 ms) was significantly smaller than that for TBF (68 +/- 28 ms, p less than 0.001) and the value for the measured diastolic left ventricular asymptote pressure (2 +/- 4 mm Hg) was significantly larger than that for the best-fit asymptote pressure (-9 +/- 11 mm Hg, p less than 0.001). T0 (44 +/- 20 ms) was significantly (p less than 0.01) different from TBF but not from T(asy). During balloon inflation of a self-positioning Inoue balloon, left ventricular pressure decayed continuously toward a positive asymptote value and left ventricular cavity volume was comparable to the left ventricular end-systolic volume of filling beats. In these nonfilling beats, the best-fit asymptote pressure was unrelated to the measured asymptote pressure and T0 was a better measure of T(asy) than was TBF. Reduced internal myocardial restoring forces, caused by different extracellular matrix of the human heart, reduced external myocardial restoring forces caused by low coronary perfusion pressure during the balloon inflation and inward motion of the balloon-occluded mitral valve into the left ventricular cavity could explain the failure to observe significant diastolic left ventricular suction in the human heart.
Ghimire, Anukul; Andersen, Mads J; Burrowes, Lindsay M; Bouwmeester, J Christopher; Grant, Andrew D; Belenkie, Israel; Fine, Nowell M; Borlaug, Barry A; Tyberg, John V
2016-12-01
Using the reservoir-wave approach (RWA) we previously characterized pulmonary vasculature mechanics in a normal canine model. We found reflected backward-traveling waves that decrease pressure and increase flow in the proximal pulmonary artery (PA). These waves decrease right ventricular (RV) afterload and facilitate RV ejection. With pathological alterations to the pulmonary vasculature, these waves may change and impact RV performance. Our objective in this study was to characterize PA wave reflection and the alterations in RV performance in cardiac patients, using the RWA. PA pressure, Doppler-flow velocity, and pulmonary arterial wedge pressure were measured in 11 patients with exertional dyspnea. The RWA was employed to analyze PA pressure and flow; wave intensity analysis characterized PA waves. Wave-related pressure was partitioned into two components: pressures due to forward-traveling and to backward-traveling waves. RV performance was assessed by examining the work done in raising reservoir pressure and that associated with the wave components of systolic PA pressure. Wave-related work, the mostly nonrecoverable energy expended by the RV to eject blood, tended to vary directly with mean PA pressure. Where PA pressures were lower, there were pressure-decreasing/flow-increasing backward waves that aided RV ejection. Where PA pressures were higher, there were pressure-increasing/flow-decreasing backward waves that impeded RV ejection. Pressure-increasing/flow-decreasing backward waves were responsible for systolic notches in the Doppler flow velocity profiles in patients with the highest PA pressure. Pulmonary hypertension is characterized by reflected waves that impede RV ejection and an increase in wave-related work. The RWA may facilitate the development of therapeutic strategies. Copyright © 2016 the American Physiological Society.
Decreased cerebral perfusion in Duchenne muscular dystrophy patients.
Doorenweerd, Nathalie; Dumas, Eve M; Ghariq, Eidrees; Schmid, Sophie; Straathof, Chiara S M; Roest, Arno A W; Wokke, Beatrijs H; van Zwet, Erik W; Webb, Andrew G; Hendriksen, Jos G M; van Buchem, Mark A; Verschuuren, Jan J G M; Asllani, Iris; Niks, Erik H; van Osch, Matthias J P; Kan, Hermien E
2017-01-01
Duchenne muscular dystrophy is caused by dystrophin gene mutations which lead to the absence of the protein dystrophin. A significant proportion of patients suffer from learning and behavioural disabilities, in addition to muscle weakness. We have previously shown that these patients have a smaller total brain and grey matter volume, and altered white matter microstructure compared to healthy controls. Patients with more distal gene mutations, predicted to affect dystrophin isoforms Dp140 and Dp427, showed greater grey matter reduction. Now, we studied if cerebral blood flow in Duchenne muscular dystrophy patients is altered, since cerebral expression of dystrophin also occurs in vascular endothelial cells and astrocytes associated with cerebral vasculature. T1-weighted anatomical and pseudo-continuous arterial spin labeling cerebral blood flow images were obtained from 26 patients and 19 age-matched controls (ages 8-18 years) on a 3 tesla MRI scanner. Group comparisons of cerebral blood flow were made with and without correcting for grey matter volume using partial volume correction. Results showed that patients had a lower cerebral blood flow than controls (40.0 ± 6.4 and 47.8 ± 6.3 mL/100 g/min respectively, p = 0.0002). This reduction was independent of grey matter volume, suggesting that they are two different aspects of the pathophysiology. Cerebral blood flow was lowest in patients lacking Dp140. There was no difference in CBF between ambulant and non-ambulant patients. Only three patients showed a reduced left ventricular ejection fraction. No correlation between cerebral blood flow and age was found. Our results indicate that cerebral perfusion is reduced in Duchenne muscular dystrophy patients independent of the reduced grey matter volume. Copyright © 2016 Elsevier B.V. All rights reserved.
Scaling the low-shear pulsatile TORVAD for pediatric heart failure
Gohean, Jeffrey R.; Larson, Erik R.; Hsi, Brian H.; Kurusz, Mark; Smalling, Richard W.; Longoria, Raul G.
2016-01-01
This article provides an overview of the design challenges associated with scaling the low-shear pulsatile TORVAD ventricular assist device (VAD) for treating pediatric heart failure. A cardiovascular system model was used to determine that a 15 ml stroke volume device with a maximum flow rate of 4 L/min can provide full support to pediatric patients with body surface areas between 0.6 to 1.5 m2. Low shear stress in the blood is preserved as the device is scaled down and remains at least two orders of magnitude less than continuous flow VADs. A new magnetic linkage coupling the rotor and piston has been optimized using a finite element model (FEM) resulting in increased heat transfer to the blood while reducing the overall size of TORVAD. Motor FEM has also been used to reduce motor size and improve motor efficiency and heat transfer. FEM analysis predicts no more than 1°C temperature rise on any blood or tissue contacting surface of the device. The iterative computational approach established provides a methodology for developing a TORVAD platform technology with various device sizes for supporting the circulation of infants to adults. PMID:27832001
Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure.
Gohean, Jeffrey R; Larson, Erik R; Hsi, Brian H; Kurusz, Mark; Smalling, Richard W; Longoria, Raul G
This article provides an overview of the design challenges associated with scaling the low-shear pulsatile TORVAD ventricular assist device (VAD) for treating pediatric heart failure. A cardiovascular system model was used to determine that a 15 ml stroke volume device with a maximum flow rate of 4 L/min can provide full support to pediatric patients with body surface areas between 0.6 and 1.5 m. Low-shear stress in the blood is preserved as the device is scaled down and remains at least two orders of magnitude less than continuous flow VADs. A new magnetic linkage coupling the rotor and piston has been optimized using a finite element model (FEM) resulting in increased heat transfer to the blood while reducing the overall size of TORVAD. Motor FEM has also been used to reduce motor size and improve motor efficiency and heat transfer. FEM analysis predicts no more than 1°C temperature rise on any blood or tissue contacting surface of the device. The iterative computational approach established provides a methodology for developing a TORVAD platform technology with various device sizes for supporting the circulation of infants to adults.
Kong, Wei; Huang, Jian; Rollins, Dennis L; Ideker, Raymond E; Smith, William M
2007-03-01
We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and coronary artery blood flow and arterial blood pressure that are suitable for use with the system. The telemetry system consists of a front end, a backpack and a host PC. The front end is a watertight stainless steel case with all sensor electronics sealed inside; it acquires dimension, flow, pressure and five cardiac electrograms from selected locations on the heart. The backpack includes a control unit, Bluetooth radio, and batteries. The control unit digitizes eight channels of data from the front end and forwards them to the host PC via Bluetooth link. The host PC has a receiving Bluetooth radio and Labview programs to store and display data. The whole system was successfully tested on the bench and in an animal model. This telemetry system will greatly enhance the ability to study events leading to spontaneous sudden cardiac arrest.
Arterial wall histology in chronic pulsatile-flow and continuous-flow device circulatory support.
Potapov, Evgenij V; Dranishnikov, Nikolay; Morawietz, Lars; Stepanenko, Alexander; Rezai, Sajjad; Blechschmidt, Cristiane; Lehmkuhl, Hans B; Weng, Yuguo; Pasic, Miralem; Hübler, Michael; Hetzer, Roland; Krabatsch, Thomas
2012-11-01
Continuous-flow (CF) ventricular assist devices (VAD) are an established option for treatment of end-stage heart failure. However, the effect of long-term CF with lack of peripheral arterial wall motions on blood pressure regulation and end-organ arterial wall sclerosis, especially in the case of long-term support (> 3 years), remains unclear. Tissue samples obtained at autopsy from liver, kidney, coronary arteries, and brain from 27 VAD recipients supported for > 180 days between 2000 and 2010 were histologically examined to assess vascular alterations, including perivascular infiltrate, intravascular infiltrate, wall thickness, thrombosis, endothelial cell swelling, vessel wall necrosis, and peri-vascular fibrosis. Pulsatile-flow (PF) devices had been inserted in 9 patients and CF devices had been inserted in 16. The pathologist was blinded to the group distribution. Demographic, pharmacologic, and clinical data were retrospectively analyzed before surgery and during the follow-up period of up to 24 months. Median duration of support was 467 days (range, 235-1,588 days) in the PF group and 263 days (range, 182-942 days) in the CF group. Demographic and clinical data before and after surgery were similar. Amiodarone was more often used during follow-up in CF group than in the PF group (61% vs 10%, p = 0.009). Throughout the follow-up period, mean arterial pressure did not differ between recipients of the 2 pump types, nor did systolic and diastolic pressure, except at 2 weeks after VAD implantation, when systolic blood pressure was higher (p = 0.05) and diastolic lower (p = 0.03) in the PF group. Histologic studies did not identify any relevant differences in arterial wall characteristics between the 2 groups. Long-term mechanical circulatory support with CF devices does not adversely influence arterial wall properties of the end-organ vasculature. Copyright © 2012 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Hochwald, Ori; Jabr, Mohammed; Osiovich, Horacio; Miller, Steven P.; McNamara, Patrick J.; Lavoie, Pascal M.
2015-01-01
Objective To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Study design Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had a cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3–4. Results LVCO was markedly reduced (mean+/−SD: 126+/−38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88+/− 27 mL/kg/min) such that it represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 +/− 13 BPM versus 123 +/− 17 BPM; p<0.001) compared to immediately post-warming, in the context of myocardial dysfunction. Neonates with documented brain injury on MRI showed higher SVC flow pre-rewarming, compared to newborns without brain injury (p=0.013). Conclusion Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. PMID:24582011
Spiral waves are stable in discrete element models of two-dimensional homogeneous excitable media
NASA Technical Reports Server (NTRS)
Feldman, A. B.; Chernyak, Y. B.; Cohen, R. J.
1998-01-01
The spontaneous breakup of a single spiral wave of excitation into a turbulent wave pattern has been observed in both discrete element models and continuous reaction-diffusion models of spatially homogeneous 2D excitable media. These results have attracted considerable interest, since spiral breakup is thought to be an important mechanism of transition from the heart rhythm disturbance ventricular tachycardia to the fatal arrhythmia ventricular fibrillation. It is not known whether this process can occur in the absence of disease-induced spatial heterogeneity of the electrical properties of the ventricular tissue. Candidate mechanisms for spiral breakup in uniform 2D media have emerged, but the physical validity of the mechanisms and their applicability to myocardium require further scrutiny. In this letter, we examine the computer simulation results obtained in two discrete element models and show that the instability of each spiral is an artifact resulting from an unphysical dependence of wave speed on wave front curvature in the medium. We conclude that spiral breakup does not occur in these two models at the specified parameter values and that great care must be exercised in the representation of a continuous excitable medium via discrete elements.
Arrhythmia during extracorporeal shock wave lithotripsy.
Zeng, Z R; Lindstedt, E; Roijer, A; Olsson, S B
1993-01-01
A prospective study of arrhythmia during extracorporeal shock wave lithotripsy (ESWL) was performed in 50 patients, using an EDAP LT01 piezoelectric lithotriptor. The 12-lead standard ECG was recorded continuously for 10 min before and during treatment. One or more atrial and/or ventricular ectopic beats occurred during ESWL in 15 cases (30%). The occurrence of arrhythmia was similar during right-sided and left-sided treatment. One patient developed multifocal ventricular premature beats and ventricular bigeminy; another had cardiac arrest for 13.5 s. It was found that various irregularities of the heart rhythm can be caused even by treatment with a lithotriptor using piezoelectric energy to create the shock wave. No evidence was found, however, that the shock wave itself rather than vagal activation and the action of sedo-analgesia was the cause of the arrhythmia. For patients with severe underlying heart disease and a history of complex arrhythmia, we suggest that the ECG be monitored during treatment. In other cases, we have found continuous monitoring of oxygen saturation and pulse rate with a pulse oximeter to be perfectly reliable for raising the alarm when depression of respiration and vaso-vagal reactions occur.
Changes in renal function after implantation of continuous-flow left ventricular assist devices.
Hasin, Tal; Topilsky, Yan; Schirger, John A; Li, Zhuo; Zhao, Yanjun; Boilson, Barry A; Clavell, Alfredo L; Rodeheffer, Richard J; Frantz, Robert P; Edwards, Brooks S; Pereira, Naveen L; Joyce, Lyle; Daly, Richard; Park, Soon J; Kushwaha, Sudhir S
2012-01-03
The aim of this study was to determine renal outcomes after left ventricular assist device (LVAD) implantation. Renal dysfunction before LVAD placement is frequent, and it is unclear whether it is due to primary renal disease or to poor perfusion. A retrospective single-center analysis was conducted in 83 consecutive patients implanted with HeartMate II continuous-flow LVADs (Thoratec Corp., Pleasanton, California). Calculated glomerular filtration rate (GFR) was assessed on admission and 1, 3, and 6 months after implantation. To define predictors for improvement in GFR, clinical variables were examined in patients with decreased renal function (GFR <60 ml/min/1.73 m(2)) before LVAD, surviving and dialysis-free at 1 month (n = 44). GFR significantly increased from admission (53.2 ± 21.4 ml/min/1.73 m(2)) to 1 month after LVAD implantation (87.4 ± 27.9 ml/min/1.73 m(2)) (p < 0.0001). Subsequently, at 3 and 6 months, GFR remained significantly (p < 0.0001) above pre-LVAD values. Of the 51 patients with GFRs <60 ml/min/1.73 m(2) before LVAD surviving at 1 month, 34 (67%) improved to GFRs >60 ml/min/1.73 m(2). Univariate pre-operative predictors for improvement in renal function at 1 month included younger age (p = 0.049), GFR improvement with optimal medical therapy (p < 0.001), intra-aortic balloon pump use (p = 0.004), kidney length above 10 cm (p = 0.023), no treatment with angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (p = 0.029), higher bilirubin (p = 0.002), higher Lietz-Miller score (p = 0.019), and atrial fibrillation (p = 0.007). Multivariate analysis indicated pre-operative improved GFR (slope = 0.5 U per unit improved; 95% confidence interval: 0.2 to 0.8; p = 0.003), atrial fibrillation (slope = 27; 95% confidence interval: 8 to 46; p = 0.006), and intra-aortic balloon pump use (slope = 14; 95% confidence interval: 2 to 26; p = 0.02) as independent predictors. In most patients with end-stage heart failure considered for LVAD implantation, renal dysfunction is reversible and likely related to poor renal perfusion. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Jularic, Mario; Akbulak, Ruken Özge; Schäffer, Benjamin; Moser, Julia; Nuehrich, Jana; Meyer, Christian; Eickholt, Christian; Willems, Stephan; Hoffmann, Boris A
2018-03-01
During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Hövels-Gürich, Hedwig H; Konrad, Kerstin; Skorzenski, Daniela; Nacken, Claudia; Minkenberg, Ralf; Messmer, Bruno J; Seghaye, Marie-Christine
2006-03-01
The purpose of this prospective study was to assess whether neurodevelopmental status and exercise capacity of children 5 to 10 years after corrective surgery for tetralogy of Fallot or ventricular septal defect in infancy was different compared with normal children and influenced by the preoperative condition of hypoxemia or cardiac insufficiency. Forty unselected children, 20 with tetralogy of Fallot and hypoxemia and 20 with ventricular septal defect and cardiac insufficiency, operated on with combined deep hypothermic circulatory arrest and low flow cardiopulmonary bypass at a mean age of 0.7 +/- 0.3 years (mean +/- SD), underwent, at mean age 7.4 +/- 1.6 years, standardized evaluation of neurologic status, gross motor function, intelligence, academic achievement, language, and exercise capacity. Results were compared between the groups and related to preoperative, perioperative, and postoperative status and management. Rate of mild neurologic dysfunction was increased compared with normal children, but not different between the groups. Exercise capacity and socioeconomic status were not different compared with normal children and between the groups. Compared with the normal population, motor function, formal intelligence, academic achievement, and expressive and receptive language were significantly reduced (p < 0.01 to p < 0.001) in the whole group and in the subgroups, except for normal intelligence in ventricular septal defect patients. Motor dysfunction was significantly higher in the Fallot group compared with the ventricular septal defect group (p < 0.01) and correlated with neurologic dysfunction, lower intelligence, and reduced expressive language (p < 0.05 each). Reduced New York Heart Association functional class was correlated with lower exercise capacity and longer duration of cardiopulmonary bypass (p < 0.05 each). Reduced socioeconomic status significantly influenced dysfunction in formal intelligence (p < 0.01) and academic achievement (p < 0.05). Preoperative risk factors such as prenatal hypoxia, perinatal asphyxia, and preterm birth, factors of perioperative management such as cardiac arrest, lowest nasopharyngeal temperature, and age at surgery, and postoperative risk factors as postoperative cardiocirculatory insufficiency and duration of mechanical ventilation were not different between the groups and had no influence on outcome. Degree of hypoxemia in Fallot patients and degree of cardiac insufficiency in ventricular septal defect patients did not influence the outcome within the subgroups. Children with preoperative hypoxemia in infancy are at higher risk for motor dysfunction than children with cardiac insufficiency. Corrective surgery in infancy for tetralogy of Fallot or ventricular septal defect with combined circulatory arrest and low flow bypass is associated with reduced neurodevelopmental outcome, but not with reduced exercise capacity in childhood. In our experience, the general risk of long-term neurodevelopmental impairment is related to unfavorable effects of the global perioperative management. Socioeconomic status influences cognitive capabilities.
Vanden Eynden, Frederic; Mets, Gilles; De Somer, Filip; Bouchez, Stefaan; Bove, Thierry
2015-10-15
Most therapeutic strategies for acute right ventricular failure (RVF) by pressure-overload are directed to improve cardiac output and coronary perfusion pressure by vasopressive agents. The eventual role of intra-aortic balloon counterpulsation (IABP) support remains questionable. This study investigates the contribution of IABP for acute RVF by pressure-overload, in comparison with phenylephrine (PE) and norepinephrine (NOR). Acute RVF is induced by fixed pulmonary artery constriction in 6 pigs, pursuing a 50% reduction of cardiac output. Assessment of the treatment interventions included biventricular PV-loop analysis, and continuous measurement of aortic and right coronary artery flow. Restoration of baseline cardiac output was only observed by administration of NOR (Baseline=3.82±1.52ml/min - RVF=2.03±0.59ml/min - IABP=2.45±0.62ml/min - PE=2.98±0.63ml/min - NOR=3.95±0.73ml/min, p<0.001). NOR had most effect on biventricular contractility (PRSW-slope-RV: IABP +24% - PE +59% - NOR +208%, p<0.001 and PRSW-slope-LV: IABP +36% - PE +53% - NOR +196%, p<0.001), heart rate acceleration (IABP +7% - PE +12% - NOR +51%, p<0.001), and RCA flow (IABP +31% - PE +58% - NOR +180%, p<0.001), concomitant to a higher increase of LV-to-RV pressure ratio (IABP: +7% versus -3%, PE: +36% versus +8%, NOR: +101% versus 42%). The hemodynamic contribution of IABP was limited, unless a modest improvement of LV compliance during PE and NOR infusion. In a model of acute pressure-overload RV failure, IABP appears to offer limited hemodynamic benefit. The administration of norepinephrine is most effective to correct systemic output and myocardial perfusion through adding an inotropic and chronotropic effect to systemic vasopression. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Marui, Akira; Nishina, Takeshi; Saji, Yoshiaki; Yamazaki, Kazuhiro; Shimamoto, Takeshi; Ikeda, Tadashi; Sakata, Ryuzo
2010-05-01
Surgical ventricular restoration (SVR) has been introduced to restore the dilated left ventricular (LV) chamber and improve LV systolic function; however, SVR has also been reported to detrimentally affect LV diastolic properties. We sought to investigate the impact of preoperative LV diastolic function on outcomes after SVR in patients with heart failure. Sixty-seven patients (60 +/- 14 years) with LV systolic dysfunction (LV ejection fraction, 0.27 +/- 0.10) underwent SVR. They were evaluated by echocardiography preoperatively, and early (
Endothelial deletion of Ino80 disrupts coronary angiogenesis and causes congenital heart disease.
Rhee, Siyeon; Chung, Jae I; King, Devin A; D'amato, Gaetano; Paik, David T; Duan, Anna; Chang, Andrew; Nagelberg, Danielle; Sharma, Bikram; Jeong, Youngtae; Diehn, Maximilian; Wu, Joseph C; Morrison, Ashby J; Red-Horse, Kristy
2018-01-25
During development, the formation of a mature, well-functioning heart requires transformation of the ventricular wall from a loose trabecular network into a dense compact myocardium at mid-gestation. Failure to compact is associated in humans with congenital diseases such as left ventricular non-compaction (LVNC). The mechanisms regulating myocardial compaction are however still poorly understood. Here, we show that deletion of the Ino80 chromatin remodeler in vascular endothelial cells prevents ventricular compaction in the developing mouse heart. This correlates with defective coronary vascularization, and specific deletion of Ino80 in the two major coronary progenitor tissues-sinus venosus and endocardium-causes intermediate phenotypes. In vitro, endothelial cells promote myocardial expansion independently of blood flow in an Ino80-dependent manner. Ino80 deletion increases the expression of E2F-activated genes and endothelial cell S-phase occupancy. Thus, Ino80 is essential for coronary angiogenesis and allows coronary vessels to support proper compaction of the heart wall.
EVALUATION OF RIGHT AND LEFT VENTRICULAR DIASTOLIC FILLING
Pasipoularides, Ares
2013-01-01
A conceptual fluid-dynamics framework for diastolic filling is developed. The convective deceleration load (CDL) is identified as an important determinant of ventricular inflow during the E-wave (A-wave) upstroke. Convective deceleration occurs as blood moves from the inflow anulus through larger-area cross-sections toward the expanding walls. Chamber dilatation underlies previously unrecognized alterations in intraventricular flow dynamics. The larger the chamber, the larger become the endocardial surface and the CDL. CDL magnitude affects strongly the attainable E-wave (A-wave) peak. This underlies the concept of diastolic ventriculoannular disproportion. Large vortices, whose strength decreases with chamber dilatation, ensue after the E-wave peak and impound inflow kinetic energy, averting an inflow-impeding, convective Bernoulli pressure-rise. This reduces the CDL by a variable extent depending on vortical intensity. Accordingly, the filling vortex facilitates filling to varying degrees, depending on chamber volume. The new framework provides stimulus for functional genomics research, aimed at new insights into ventricular remodeling. PMID:23585308
Niwa, Koichiro
2017-12-01
Marfan syndrome, bicuspid aortic valve, and/or coarctation of the aorta are associated with medial abnormalities of the ascending aortic or para-coarctation aorta. Medial abnormalities in the ascending aorta are prevalent in other type of patients with a variety of CHDs such as single ventricle, persistent truncus arteriosus, transposition of the great arteries, hypoplastic left heart syndrome, and tetralogy of Fallot, encompassing a wide age range and may predispose to dilatation, aneurysm, and rapture necessitating aortic valve and root surgery. These CHDs exhibit ongoing dilatation of the aortic root and reduced aortic elasticity and increased aortic stiffness that may relate to intrinsic properties of the aortic root. These aortic dilatation and increased stiffness can induce aortic aneurysm, rapture of the aorta, and aortic regurgitation, but also provoke left ventricular hypertrophy, reduced coronary artery flow, and left ventricular failure. Therefore, a new clinical entity can be used to call this association of aortic pathophysiological abnormality, aortic dilation, and aorto-left ventricular interaction - "aortopathy".
Impact of Major Pulmonary Resections on Right Ventricular Function: Early Postoperative Changes.
Elrakhawy, Hany M; Alassal, Mohamed A; Shaalan, Ayman M; Awad, Ahmed A; Sayed, Sameh; Saffan, Mohammad M
2018-01-15
Right ventricular (RV) dysfunction after pulmonary resection in the early postoperative period is documented by reduced RV ejection fraction and increased RV end-diastolic volume index. Supraventricular arrhythmia, particularly atrial fibrillation, is common after pulmonary resection. RV assessment can be done by non-invasive methods and/or invasive approaches such as right cardiac catheterization. Incorporation of a rapid response thermistor to pulmonary artery catheter permits continuous measurements of cardiac output, right ventricular ejection fraction, and right ventricular end-diastolic volume. It can also be used for right atrial and right ventricular pacing, and for measuring right-sided pressures, including pulmonary capillary wedge pressure. This study included 178 patients who underwent major pulmonary resections, 36 who underwent pneumonectomy assigned as group (I) and 142 who underwent lobectomy assigned as group (II). The study was conducted at the cardiothoracic surgery department of Benha University hospital in Egypt; patients enrolled were operated on from February 2012 to February 2016. A rapid response thermistor pulmonary artery catheter was inserted via the right internal jugular vein. Preoperatively the following was recorded: central venous pressure, mean pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac output, right ventricular ejection fraction and volumes. The same parameters were collected in fixed time intervals after 3 hours, 6 hours, 12 hours, 24 hours, and 48 hours postoperatively. For group (I): There were no statistically significant changes between the preoperative and postoperative records in the central venous pressure and mean arterial pressure; there were no statistically significant changes in the preoperative and 12, 24, and 48 hour postoperative records for cardiac index; 3 and 6 hours postoperative showed significant changes. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index, in all postoperative records. For group (II): There were no statistically significant changes between the preoperative and all postoperative records for the central venous pressure, mean arterial pressure and cardiac index. There were statistically significant changes between the preoperative and postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index in all postoperative records. There were statistically significant changes between the two groups in all postoperative records for heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction and right ventricular end diastolic volume index. There is right ventricular dysfunction early after major pulmonary resection caused by increased right ventricular afterload. This dysfunction is more present in pneumonectomy than in lobectomy. Heart rate, mean pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, right ventricular ejection fraction, and right ventricular end diastolic volume index are significantly affected by pulmonary resection.
Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Zhang, Jin-Ping; Wu, Wei-Chun; Wang, Hao
2015-10-01
The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction. © 2015 by the American Institute of Ultrasound in Medicine.
Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M
1997-11-05
To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.
What the Psychiatrist Needs to Know About Ventricular Assist Devices: A Comprehensive Review.
Caro, Mario A; Rosenthal, Julie L; Kendall, Kay; Pozuelo, Leopoldo; Funk, Margo C
2016-01-01
The number of patients with end-stage heart failure using mechanical circulatory support has dramatically increased over the past decade. Left ventricular assist devices, the most common type of mechanical circulatory support, can be used as a bridge to transplant, destination therapy, and as a bridge to recovery. As this patient population continues to grow, consultation-liaison psychiatrists will become increasingly involved in their care. A thorough biopsychosocial assessment is required to ensure adequate recognition and management of medical, psychiatric, social, and ethical challenges posed by this population. We performed a literature review to identify key issues relevant to the practice of consultation-liaison psychiatrists. General functioning of left ventricular assist devices, device types, system components, life with a left ventricular assist device, preoperative evaluation, treatment of psychiatric comorbidities, and end-of-life decision-making are discussed. Consultation-liaison psychiatrists need to be familiar with the high prevalence of psychopathology in patients implanted with left ventricular assist devices. A detailed biopsychosocial formulation is required to adequately identify and, if possible, resolve a myriad of medical, psychiatric, social, and ethical challenges presented by this population. Future efforts should accurately identify and report specific psychiatric disorders and adverse events within this cohort. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.
Ghosal, Soutik; Trivedi, Jaimin; Chen, James; Rogers, Michael P; Cheng, Allen; Slaughter, Mark S; Kong, Maiying; Huang, Jiapeng
2018-06-01
Left ventricular assist device (LVAD) surgery is complex, high risk, and expensive. The authors' hypothesis is baseline regional cerebral oxygen saturation (rSO 2 ) might be a predictor of postoperative clinical outcomes. Retrospective review of 210 consecutive continuous flow LVAD patients between 2008 and 2014. The primary measure is 30-day mortality rate and secondary measures include modified major adverse cardiocerebral events (MACE), length of stay (LOS), and intensive care unit (ICU) stay. Multiple logistic regression models were applied to examine if a binary outcome variable, such as 30-day mortality and MACE, is associated with rSO 2 at baseline. Log-linear model was used to examine whether LOS or ICU stay hours is associated with rSO 2 at baseline. Single institution, academic hospital. Patients who received LVAD surgery at Jewish Hospital, Louisville, KY. All patients received LVAD surgery. Cerebral oximetry monitoring was used in both the preoperative and intraoperative periods. The authors found that higher rSO 2 at baseline is associated with lower 30-day mortality with an odds ratio of 0.94 and 95% confidence interval (0.888, 0.995) for every 1% increase of rSO 2 . For secondary outcomes, baseline rSO 2 was not significantly associated with MACE, requirement for postoperative renal failure/dialysis, reoperation for bleeding, and LOS or ICU hours. Regional cerebral oxygen saturation levels at baseline are significantly associated with 30-day mortality after LVAD surgeries. Copyright © 2017 Elsevier Inc. All rights reserved.
Nelson, Jonas A; Shaked, Oren; Fischer, John P; Mirzabeigi, Michael N; Jandali, Shareef; Kovach, Stephen J; Low, David W; Acker, Michael A; Kanchwala, Suhail K
2014-12-01
Infections and complex wounds after ventricular assist device (VAD) placement can result in significant morbidity and mortality. The purpose of this study was to evaluate complex wound management in the VAD patient, and to describe a treatment protocol for these challenging and potentially mortal complications. A retrospective study was performed to examine all patients who underwent continuous flow, second-generation VAD placement at the Hospital of the University of Pennsylvania between March 2008 and April 2013. Overall, 150 VADs were placed, with 12 (8%) patients requiring 15 operative interventions by the plastic surgery services. The most common indication for operative intervention was a complicated wound with VAD exposure (5/12, 41.7%). All patients underwent aggressive operative debridement, and 11/12 (92%) underwent vascularized soft tissue coverage. Flaps commonly utilized included rectus abdominus myocutaneous (n = 4), rectus abdominus muscle (n = 4), pectoralis major (n = 3), and omentum (n = 3). Three patients experienced complications which required a return to the operating room, including 1 flap loss, 1 hematoma, and 1 wound dehiscence requiring further soft tissue coverage. Salvage was achieved, yet a 50% mortality rate in follow-up was noted. Complex wound management in VAD patients can be achieved with aggressive debridement and vascularized soft tissue coverage, most commonly utilizing well-vascularized rectus abdominus muscle or omental flaps. Plastic surgeons should be familiar with the armamentarium at their disposal when approaching these challenging cases as VAD wound complications stand to become an increasingly prevalent issue.
Neuroimaging in normal pressure hydrocephalus
Damasceno, Benito Pereira
2015-01-01
Normal pressure hydrocephalus (NPH) is a syndrome characterized by the triad of gait disturbance, mental deterioration and urinary incontinence, associated with ventriculomegaly and normal cerebrospinal fluid (CSF) pressure. The clinical presentation (triad) may be atypical or incomplete, or mimicked by other diseases, hence the need for supplementary tests, particularly to predict postsurgical outcome, such as CSF tap-tests and computed tomography (CT) or magnetic resonance imaging (MRI). The CSF tap-test, especially the 3 to 5 days continuous external lumbar drainage of at least 150 ml/day, is the only procedure that simulates the effect of definitive shunt surgery, with high sensitivity (50-100%) and high positive predictive value (80-100%). According to international guidelines, the following are CT or MRI signs decisive for NPH diagnosis and selection of shunt-responsive patients: ventricular enlargement disproportionate to cerebral atrophy (Evans index >0.3), and associated ballooning of frontal horns; periventricular hyperintensities; corpus callosum thinning and elevation, with callosal angle between 40º and 90º; widening of temporal horns not fully explained by hippocampal atrophy; and aqueductal or fourth ventricular flow void; enlarged Sylvian fissures and basal cistern, and narrowing of sulci and subarachnoid spaces over the high convexity and midline surface of the brain. On the other hand, other imaging methods such as radionuclide cisternography, SPECT, PET, and also DTI or resting-state functional MRI, although suitable for NPH diagnosis, do not yet provide improved accuracy for identifying shunt-responsive cases. PMID:29213984
Grandin, E Wilson; Zamani, Payman; Mazurek, Jeremy A; Troutman, Gregory S; Birati, Edo Y; Vorovich, Esther; Chirinos, Julio A; Tedford, Ryan J; Margulies, Kenneth B; Atluri, Pavan; Rame, J Eduardo
2017-01-01
Right ventricular (RV) adaptation to afterload is crucial for patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. We hypothesized that stratifying patients by RV pulsatile load, using pulmonary arterial compliance (PAC), and RV response to load, using the ratio of central venous to pulmonary capillary wedge pressure (CVP:PCWP), would identify patients at high risk for early right heart failure (RHF) and 6-month mortality after cf-LVAD. During the period from January 2008 to June 2014, we identified 151 patients at our center with complete hemodynamics prior to cf-LVAD. Pulsatile load was estimated using PAC indexed to body surface area (BSA), according to the formula: indexed PAC (PACi) = [SV / (PA systolic - PA diastolic )] / BSA, where SV is stroke volume and PA is pulmonary artery. Patients were divided into 4 hemodynamic groups by PACi and CVP:PCWP. RHF was defined as the need for unplanned RVAD, inotropic support ≥14 days or death due to RHF within 14 days. Risk factors for RHF and 6-month mortality were examined using logistic regression and Cox proportional hazards modeling. Sixty-one patients (40.4%) developed RHF and 34 patients (22.5%) died within 6 months. Patients with RHF had lower PACi (0.92 vs 1.17 ml/mm Hg/m 2 , p = 0.008) and higher CVP:PCWP (0.48 vs 0.37, p = 0.001). Higher PACi was associated with reduced risk of RHF (adjusted odds ratio [adj-OR] 0.61, 95% confidence interval [CI] 0.39 to 0.94, p = 0.025) and low PACi with increased risk of 6-month mortality (adjusted hazard ratio [adj-HR] 3.18, 95% CI 1.40 to 7.25, p = 0.006). Compared to patients with low load (high PACi) and adequate right heart response to load (low CVP:PCWP), patients with low PACi and high CVP:PCWP had an increased risk of RHF (OR 4.74, 95% CI 1.23 to 18.24, p = 0.02) and 6-month mortality (HR 8.68, 95% CI 2.79 to 26.99, p < 0.001). A hemodynamic profile combining RV pulsatile load and response to load identifies patients at high risk for RHF and 6-month mortality after cf-LVAD. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Kimura, Sumito; Streiff, Cole; Zhu, Meihua; Shimada, Eriko; Datta, Saurabh; Ashraf, Muhammad; Sahn, David J
2014-02-01
The aim of this study was to assess the accuracy, feasibility, and reproducibility of determining stroke volume from a novel 3-dimensional (3D) color Doppler flow quantification method for mitral valve (MV) inflow and left ventricular outflow tract (LVOT) outflow at different stroke volumes when compared with the actual flow rate in a pumped porcine cardiac model. Thirteen freshly harvested pig hearts were studied in a water tank. We inserted a latex balloon into each left ventricle from the MV annulus to the LVOT, which were passively pumped at different stroke volumes (30-80 mL) using a calibrated piston pump at increments of 10 mL. Four-dimensional flow volumes were obtained without electrocardiographic gating. The digital imaging data were analyzed offline using prototype software. Two hemispheric flow-sampling planes for color Doppler velocity measurements were placed at the MV annulus and LVOT. The software computed the flow volumes at the MV annulus and LVOT within the user-defined volume and cardiac cycle. This novel 3D Doppler flow quantification method detected incremental increases in MV inflow and LVOT outflow in close agreement with pumped stroke volumes (MV inflow, r = 0.96; LVOT outflow, r = 0.96; P < .01). Bland-Altman analysis demonstrated overestimation of both (MV inflow, 5.42 mL; LVOT outflow, 4.46 mL) with 95% of points within 95% limits of agreement. Interobserver variability values showed good agreement for all stroke volumes at both the MV annulus and LVOT. This study has shown that the 3D color Doppler flow quantification method we used is able to compute stroke volumes accurately at the MV annulus and LVOT in the same cardiac cycle without electrocardiographic gating. This method may be valuable for assessment of cardiac output in clinical studies.
Abramov, Dmitry; Haglund, Nicholas A; Di Salvo, Thomas G
2017-08-01
Although milrinone infusion is reported to benefit left ventricular function in chronic left heart failure, few insights exist regarding its effects on pulmonary circulation and right ventricular function. We retrospectively reviewed right heart catheterization data at baseline and during continuous infusion of milrinone in 69 patients with advanced heart failure and analyzed the effects on ventricular stroke work indices, pulmonary vascular resistance and pulmonary arterial compliance. Compared to baseline, milrinone infusion after a mean 58 ± 61 days improved mean left ventricular stroke work index (1540 ± 656 vs. 2079 ± 919 mmHg·mL/m 2 , p = 0.0007) to a much greater extent than right ventricular stroke work index (616 ± 346 vs. 654 ± 332, p = 0.053); however, patients with below median stroke work indices experienced a significant improvement in both left and right ventricular stroke work performance. Overall, milrinone reduced left and right ventricular filling pressures and pulmonary and systemic vascular resistance by approximately 20%. Despite an increase in pulmonary artery capacitance (2.3 ± 1.6 to 3.0 ± 2.0, p = 0.013) and a reduction in pulmonary vascular resistance (3.8 ± 2.3 to 3.0 ± 1.7 Wood units), milrinone did not reduce the transpulmonary gradient (13 ± 7 vs. 12 ± 6 mmHg, p = 0.252), the pulmonary artery pulse pressure (25 ± 10 vs. 24 ± 10, p = 0.64) or the pulmonary artery diastolic to pulmonary capillary wedge gradient (2.0 ± 6.5 vs. 2.4 ± 6.0, p = 0.353). Milrinone improved left ventricular stroke work indices to a greater extent than right ventricular stroke work indices and had beneficial effects on right ventricular net input impedance, predominantly via augmentation of left ventricular stroke volume and passive unloading of the pulmonary circuit. Patients who had the worst biventricular performance benefited the most from chronic milrinone infusion.
Garson, Christopher D; Li, Bing; Acton, Scott T; Hossack, John A
2008-06-01
The active surface technique using gradient vector flow allows semi-automated segmentation of ventricular borders. The accuracy of the algorithm depends on the optimal selection of several key parameters. We investigated the use of conservation of myocardial volume for quantitative assessment of each of these parameters using synthetic and in vivo data. We predicted that for a given set of model parameters, strong conservation of volume would correlate with accurate segmentation. The metric was most useful when applied to the gradient vector field weighting and temporal step-size parameters, but less effective in guiding an optimal choice of the active surface tension and rigidity parameters.
Miranda, Berta; Barrabés, José A; Figueras, Jaume; Pineda, Victor; Rodríguez-Palomares, José; Lidón, Rosa-Maria; Sambola, Antonia; Bañeras, Jordi; Otaegui, Imanol; García-Dorado, David
2016-01-01
Bilirubin may elicit cardiovascular protection and heme oxygenase-1 overexpression attenuated post-infarction ventricular remodeling in experimental animals, but the association between bilirubin levels and post-infarction remodeling is unknown. In 145 patients with a first anterior ST-segment elevation acute myocardial infarction (STEMI), we assessed whether plasma bilirubin on admission predicted adverse remodeling (left ventricular end-diastolic volume [LVEDV] increase ≥20% between discharge and 6 months, estimated by magnetic resonance imaging). Patients' baseline characteristics and management were comparable among bilirubin tertiles. LVEDV increased at 6 months (P < 0.001) with respect to the initial exam, but the magnitude of this increase was similar across increasing bilirubin tertiles (10.8 [30.2], 10.1 [22.9], and 12.7 [24.3]%, P = 0.500). Median (25-75 percentile) bilirubin values in patients with and without adverse remodeling were 0.75 (0.60-0.93) and 0.73 (0.60-0.92) mg/dL (P = 0.693). Absence of final TIMI flow grade 3 (odds ratio 3.92, 95% CI 1.12-13.66) and a history of hypertension (2.04, 0.93-4.50), but not admission bilirubin, were independently associated with adverse remodeling. Bilirubin also did not predict the increase in ejection fraction at 6 months. Admission bilirubin values are not related to LVEDV or ejection fraction progression after a first anterior STEMI and do not predict adverse ventricular remodeling. Key messages Bilirubin levels are inversely related to cardiovascular disease, and overexpression of heme oxygenase-1 (the enzyme that determines bilirubin production) has prevented post-infarction ventricular remodeling in experimental animals, but the association between bilirubin levels and the progression of ventricular volumes and function in patients with acute myocardial infarction remained unexplored. In this cohort of patients with a first acute anterior ST-segment elevation myocardial infarction receiving contemporary management, bilirubin levels on admission were not predictive of the changes in left ventricular volumes or ejection fraction at 6 months measured by serial cardiac magnetic resonance imaging. The data are contrary to a significant protective effect of bilirubin against post-infarction ventricular remodeling.
Cerier, Emily; Lampert, Brent C; Kilic, Arman; McDavid, Asia; Deo, Salil V; Kilic, Ahmet
2016-01-01
Advanced heart failure has been traditionally treated via either heart transplantation, continuous inotropes, consideration for hospice and more recently via left ventricular assist devices (LVAD). Heart transplantation has been limited by organ availability and the futility of other options has thrust LVAD therapy into the mainstream of therapy for end stage heart failure. Improvements in technology and survival combined with improvements in the quality of life have made LVADs a viable option for many patients suffering from heart failure. The question of when to implant these devices in those patients with advanced, yet still ambulatory heart failure remains a controversial topic. We discuss the current state of LVAD therapy and the risk vs benefit of these devices in the treatment of heart failure. PMID:28070237