In-situ continuous water analyzing module
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid analyzing system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectometer and the volatile components are continuously analyzed by the mass spectrometer.
In-situ continuous water monitoring system
Thompson, Cyril V.; Wise, Marcus B.
1998-01-01
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer.
In-situ continuous water monitoring system
Thompson, C.V.; Wise, M.B.
1998-03-31
An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer. 2 figs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... change the system response. (b) Measurement principles. This procedure verifies that the updating and... gas detectors used to generate a continuously combined/compensated concentration measurement signal... verifies that the measurement system meets a minimum response time. For this procedure, ensure that all...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications § 1065.308 Continuous..., the gas concentrations must be adjusted to account for the dilution from ambient air drawn into the... recommended when blending span gases diluted in N2 with span gases diluted in air. You may use a multi-gas...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications § 1065.308 Continuous..., the gas concentrations must be adjusted to account for the dilution from ambient air drawn into the... recommended when blending span gases diluted in N2 with span gases diluted in air. You may use a multi-gas...
21 CFR 868.1400 - Carbon dioxide gas analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon dioxide gas analyzer. 868.1400 Section 868.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1400 Carbon dioxide gas analyzer. (a) Identification. A carbon dioxide gas analyzer...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications § 1065.308 Continuous... adjusted to account for the dilution from ambient air drawn into the probe. We recommend you use the final... gases diluted in air. You may use a multi-gas span gas, such as NO-CO-CO2-C3H8-CH4, to verify multiple...
21 CFR 868.1430 - Carbon monoxide gas analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868.1430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a) Identification. A carbon monoxide gas...
Hanson, M.L.; Tabor, C.D. Jr.
1961-12-01
A mass spectrometer for analyzing the components of a gas is designed which is capable of continuous automatic operation such as analysis of samples of process gas from a continuous production system where the gas content may be changing. (AEC)
21 CFR 868.1500 - Enflurane gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Enflurane gas analyzer. 868.1500 Section 868.1500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1500 Enflurane gas analyzer. (a...
21 CFR 868.1620 - Halothane gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Halothane gas analyzer. 868.1620 Section 868.1620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1620 Halothane gas analyzer. (a...
21 CFR 868.1075 - Argon gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Argon gas analyzer. 868.1075 Section 868.1075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1075 Argon gas analyzer. (a) Identification. An...
21 CFR 868.1075 - Argon gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Argon gas analyzer. 868.1075 Section 868.1075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1075 Argon gas analyzer. (a) Identification. An...
Code of Federal Regulations, 2010 CFR
2010-07-01
... which you sample and record gas-analyzer concentrations. (b) Measurement principles. This test verifies... appropriate frequency to prevent loss of information. This test also verifies that the measurement system... instructions. Adjust the measurement system as needed to optimize performance. Run this verification with the...
Comparative study of gas-analyzing systems designed for continuous monitoring of TPP emissions
NASA Astrophysics Data System (ADS)
Kondrat'eva, O. E.; Roslyakov, P. V.
2017-06-01
Determining the composition of combustion products is important in terms of both control of emissions into the atmosphere from thermal power plants and optimization of fuel combustion processes in electric power plants. For this purpose, the concentration of oxygen, carbon monoxide, nitrogen, and sulfur oxides in flue gases is monitored; in case of solid fuel combustion, fly ash concentration is monitored as well. According to the new nature conservation law in Russia, all large TPPs shall be equipped with continuous emission monitoring and measurement systems (CEMMS) into the atmosphere. In order to ensure the continuous monitoring of pollutant emissions, direct round-the-clock measurements are conducted with the use of either domestically produced or imported gas analyzers and analysis systems, the operation of which is based on various physicochemical methods and which can be generally used when introducing CEMMS. Depending on the type and purposes of measurement, various kinds of instruments having different features may be used. This article represents a comparative study of gas-analysis systems for measuring the content of polluting substances in exhaust gases based on various physical and physicochemical analysis methods. It lists basic characteristics of the methods commonly applied in the area of gas analysis. It is proven that, considering the necessity of the long-term, continuous operation of gas analyzers for monitoring and measurement of pollutant emissions into the atmosphere, as well as the requirements for reliability and independence from aggressive components and temperature of the gas flow, it is preferable to use optical gas analyzers for the aforementioned purposes. In order to reduce the costs of equipment comprising a CEMMS at a TPP and optimize the combustion processes, electrochemical and thermomagnetic gas analyzers may also be used.
Code of Federal Regulations, 2013 CFR
2013-07-01
... discrete-mode testing. For this check we consider water vapor a gaseous constituent. This verification does... for water removed from the sample done in post-processing according to § 1065.659 and it does not... humidification vessel that contains water. You must humidify NO2 span gas with another moist gas stream. We...
Code of Federal Regulations, 2014 CFR
2014-07-01
... discrete-mode testing. For this check we consider water vapor a gaseous constituent. This verification does... for water removed from the sample done in post-processing according to § 1065.659 (40 CFR 1066.620 for... contains water. You must humidify NO2 span gas with another moist gas stream. We recommend humidifying your...
Real-time exhaust gas modular flowmeter and emissions reporting system for mobile apparatus
NASA Technical Reports Server (NTRS)
Breton, Leo Alphonse Gerard (Inventor)
2002-01-01
A real-time emissions reporting system includes an instrument module adapted to be detachably connected to the exhaust pipe of a combustion engine to provide for flow of exhaust gas therethrough. The instrument module includes a differential pressure probe which allows for determination of flow rate of the exhaust gas and a gas sampling tube for continuously feeding a sample of the exhaust gas to a gas analyzer or a mounting location for a non-sampling gas analyzer. In addition to the module, the emissions reporting system also includes an elastomeric boot for detachably connecting the module to the exhaust pipe of the combustion engine, a gas analyzer for receiving and analyzing gases sampled within the module and a computer for calculating pollutant mass flow rates based on concentrations detected by the gas analyzer and the detected flowrate of the exhaust gas. The system may also include a particulate matter detector with a second gas sampling tube feeding same mounted within the instrument module.
Katz, S.; Weber, C.W.
1960-02-16
A reagent gas and a sample gas are chemically combined on a continuous basis in a reaction zone maintained at a selected temperature. The reagent gas and the sample gas are introduced to the reaction zone at preselected. constant molar rates of flow. The reagent gas and the selected gas in the sample mixture combine in the reaction zone to form a product gas having a different number of moles from the sum of the moles of the reactants. The difference in the total molar rates of flow into and out of the reaction zone is measured and indicated to determine the concentration of the selected gas.
21 CFR 868.1620 - Halothane gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... infrared or ultraviolet radiation. (b) Classification. Class II (performance standards). ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Halothane gas analyzer. 868.1620 Section 868.1620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
Continuous analysis of nitrogen dioxide in gas streams of plants
NASA Technical Reports Server (NTRS)
Durkin, W. T.; Kispert, R. C.
1969-01-01
Analyzer and sampling system continuously monitors nitrogen dioxide concentrations in the feed and tail gas streams of a facility recovering nitric acid. The system, using a direct calorimetric approach, makes use of readily available equipment and is flexible and reliable in operation.
A continuous physiological data collector
NASA Technical Reports Server (NTRS)
Bush, J. C.
1972-01-01
COP-DAC system utilizes oxygen and carbon dioxide analyzers, gas-flow meter, gas breathe-through system, analog computer, and data storage system to provide actual rather than average measurements of physiological and metabolic functions.
Kimoto, Hideshi; Nozaki, Ken; Kudo, Setsuko; Kato, Ken; Negishi, Akira; Kayanne, Hajime
2002-03-01
A fully automated, continuous-flow-through type analyzer was developed to observe rapid changes in the concentration of total inorganic carbon (CT) in coastal zones. Seawater and an H3PO4 solution were fed into the analyzer's mixing coil by two high-precision valveless piston pumps. The CO2 was stripped from the seawater and moved into a carrier gas, using a newly developed continuous-flow-through CO2 extractor. A mass flow controller was used to assure a precise flow rate of the carrier gas. The CO2 concentration was then determined with a nondispersive infrared gas analyzer. This analyzer achieved a time-resolution of as good as 1 min. In field experiments on a shallow reef flat of Shiraho (Ishigaki Island, Southwest Japan), the analyzer detected short-term, yet extreme, variations in CT which manual sampling missed. Analytical values obtained by the analyzer on the boat were compared with those determined by potentiometric titration with a closed cell in a laboratory: CT(flow-through) = 0.980 x CT(titration) + 38.8 with r2 = 0.995 (n = 34; September 1998).
40 CFR 75.11 - Specific provisions for monitoring SO2 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... wood and 14.0% for natural gas (boilers, only); or (2) Install, operate, maintain, and quality assure a continuous moisture monitoring system for measuring and recording the moisture content of the flue gases, in... monitoring systems are acceptable: a continuous moisture sensor; an oxygen analyzer (or analyzers) capable of...
40 CFR 75.11 - Specific provisions for monitoring SO2 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wood and 14.0% for natural gas (boilers, only); or (2) Install, operate, maintain, and quality assure a continuous moisture monitoring system for measuring and recording the moisture content of the flue gases, in... monitoring systems are acceptable: a continuous moisture sensor; an oxygen analyzer (or analyzers) capable of...
Code of Federal Regulations, 2012 CFR
2012-07-01
... for water removed from the sample done in post-processing according to § 1065.659 and it does not... initial installation (i.e., test cell commissioning) and after any modifications to the system that would... concentration is updated and recorded at an appropriate frequency to prevent loss of information. This test also...
Code of Federal Regulations, 2011 CFR
2011-07-01
... for water removed from the sample done in post-processing according to § 1065.659 and it does not... initial installation (i.e., test cell commissioning) and after any modifications to the system that would... concentration is updated and recorded at an appropriate frequency to prevent loss of information. This test also...
Code of Federal Regulations, 2011 CFR
2011-07-01
... meets a minimum response time. You may use the results of this test to determine transformation time, t... you use any analog or real-time digital filters during emission testing, you must operate those... the rise time and fall time as needed. You may also configure analog or digital filters before...
NASA Astrophysics Data System (ADS)
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Atmospheric Carbon Dioxide Record from In Situ Measurements at Baring Head (1970 - 1993)
Manning, M. R. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand; Gomez, A. J. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand; Pohl, K. P. [National Institute of Water and Atmospheric Research, Ltd. Lower Hutt, New Zealand
1994-01-01
Determinations of atmospheric CO2 mixing ratios are made using a Siemens Ultramat-3 nondispersive infrared (NDIR) gas analyzer. The NDIR CO2 analyzer is connected via a gas manifold consisting of stainless steel tubing and computer-controlled solenoid switches to 12 gas cylinders and 2 sample air lines. The NDIR analyzer compares ambient air CO2 mixing ratios relative to known CO2 mixing ratios in tanks of compressed reference gases. The analyzer operates in a differential mode, with a "zero" reference gas of CO2 mixing ratio 20 to 30 parts per million (ppm) below ambient air CO2 levels flowing continuously through one cell of the analyzer at ~10 mL/min. When atmospheric CO2 is measured, a diaphragm pump pulls air through a sampling line at ~5 L/min. A small fraction of this (180 mL/min) is dried cryogenically to a temperature of approximately ¬70° Celsius and passed through the sample cell of the CO2 analyzer. Both the "zero" and sample gas are exhausted into the observatory building.
Zhou, Junwen; Liu, Shiyu; Zhou, Nan; Fan, Liangliang; Zhang, Yaning; Peng, Peng; Anderson, Erik; Ding, Kuan; Wang, Yunpu; Liu, Yuhuan; Chen, Paul; Ruan, Roger
2018-05-01
A continuous fast microwave-assisted pyrolysis system was designed, fabricated, and tested with sewage sludge. The system is equipped with continuous biomass feeding, mixing of biomass and microwave absorbent, and separated catalyst upgrading. The effect of the sludge pyrolysis temperature (450, 500, 550, and 600 °C) on the products yield, distribution and potentially energy recovery were investigated. The physical, chemical, and energetic properties of the raw sewage sludge and bio-oil, char and gas products obtained were analyzed using elemental analyzer, GC-MS, Micro-GC, SEM and ICP-OES. While the maximum bio-oil yield of 41.39 wt% was obtained at pyrolysis temperature of 550 °C, the optimal pyrolysis temperature for maximum overall energy recovery was 500 °C. The absence of carrier gas in the process may be responsible for the high HHV of gas products. This work could provide technical support for microwave-assisted system scale-up and sewage sludge utilization. Copyright © 2018 Elsevier Ltd. All rights reserved.
40 CFR 63.1573 - What are my monitoring alternatives?
Code of Federal Regulations, 2014 CFR
2014-07-01
... operate a continuous gas analyzer to measure and record the concentration of carbon dioxide, carbon... control room instrumentations, dscm/min (dscf/min); %CO2 = Carbon dioxide concentration in regenerator... catalytic regenerator atmospheric exhaust gas flow rate for your catalytic reforming unit during the coke...
40 CFR 63.1573 - What are my monitoring alternatives?
Code of Federal Regulations, 2012 CFR
2012-07-01
... operate a continuous gas analyzer to measure and record the concentration of carbon dioxide, carbon... control room instrumentations, dscm/min (dscf/min); %CO2 = Carbon dioxide concentration in regenerator... catalytic regenerator atmospheric exhaust gas flow rate for your catalytic reforming unit during the coke...
40 CFR 63.1573 - What are my monitoring alternatives?
Code of Federal Regulations, 2013 CFR
2013-07-01
... continuous gas analyzer to measure and record the concentration of carbon dioxide, carbon monoxide, and... instrumentations, dscm/min (dscf/min); %CO2 = Carbon dioxide concentration in regenerator exhaust, percent by... regenerator atmospheric exhaust gas flow rate for your catalytic reforming unit during the coke burn and...
40 CFR 86.331-79 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86... difference between the span-gas response and the zero-gas response. Incrementally adjust the fuel flow above...
40 CFR 86.331-79 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for New Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86... difference between the span-gas response and the zero-gas response. Incrementally adjust the fuel flow above...
An automatic gas chromatograph with a flame photometric detector that samples and analyzes hydrogen sulfide and carbonyl sulfide at 30-s intervals is described. Temperature programming was used to elute trace amounts of carbon disulfide present in each injection from a Supelpak-S...
Wise, Marcus B.; Thompson, Cyril V.
1998-01-01
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds.
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
Non Lyapunov stability of a constant spatially developing 2-D gas flow
NASA Astrophysics Data System (ADS)
Balint, Agneta M.; Balint, Stefan; Tanasie, Loredana
2017-01-01
Different types of stabilities (global, local) and instabilities (global absolute, local convective) of the constant spatially developing 2-D gas flow are analyzed in a particular phase space of continuously differentiable functions, endowed with the usual algebraic operations and the topology generated by the uniform convergence on the plane. For this purpose the Euler equations linearized at the constant flow are used. The Lyapunov stability analysis was presented in [1] and this paper is a continuation of [1].
2010-02-01
the flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a...umbilical line, a vacuum pump, a dry gas meter, and a calibrated orifice connected to an inclined oil manometer. The moisture content was less than 2% so...flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a chromel
Wise, M.B.; Thompson, C.V.
1998-07-14
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds. 3 figs.
49 CFR 192.617 - Investigation of failures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS... operator shall establish procedures for analyzing accidents and failures, including the selection of...
40 CFR 86.111-90 - Exhaust gas analytical system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the determination of carbon monoxide... analyzers may be used if shown to yield equivalent results and if approved in advance by the Administrator...
40 CFR 86.111-90 - Exhaust gas analytical system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the determination of carbon monoxide... analyzers may be used if shown to yield equivalent results and if approved in advance by the Administrator...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
NASA Astrophysics Data System (ADS)
Balint, Stefan; Balint, Agneta M.
2017-01-01
Different types of stabilities (global, local) and instabilities (global absolute, local convective) of the constant spatially developing 1-D gas flow are analyzed in the phase space of continuously differentiable functions, endowed with the usual algebraic operations and the topology generated by the uniform convergence on the real axis. For this purpose the Euler equations linearized at the constant flow are used. The Lyapunov stability analysis was presented in [1] and this paper is a continuation of [1].
Design and Testing of Trace Contaminant Injection and Monitoring Systems
NASA Technical Reports Server (NTRS)
Broerman, Craig D.; Sweterlitsch, Jeff
2009-01-01
In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.
Continuous intra-arterial blood-gas monitoring
NASA Astrophysics Data System (ADS)
Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.
1993-05-01
Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.
Transient pressure analysis of fractured well in bi-zonal gas reservoirs
NASA Astrophysics Data System (ADS)
Zhao, Yu-Long; Zhang, Lie-Hui; Liu, Yong-hui; Hu, Shu-Yong; Liu, Qi-Guo
2015-05-01
For hydraulic fractured well, how to evaluate the properties of fracture and formation are always tough jobs and it is very complex to use the conventional method to do that, especially for partially penetrating fractured well. Although the source function is a very powerful tool to analyze the transient pressure for complex structure well, the corresponding reports on gas reservoir are rare. In this paper, the continuous point source functions in anisotropic reservoirs are derived on the basis of source function theory, Laplace transform method and Duhamel principle. Application of construction method, the continuous point source functions in bi-zonal gas reservoir with closed upper and lower boundaries are obtained. Sequentially, the physical models and transient pressure solutions are developed for fully and partially penetrating fractured vertical wells in this reservoir. Type curves of dimensionless pseudo-pressure and its derivative as function of dimensionless time are plotted as well by numerical inversion algorithm, and the flow periods and sensitive factors are also analyzed. The source functions and solutions of fractured well have both theoretical and practical application in well test interpretation for such gas reservoirs, especial for the well with stimulated reservoir volume around the well in unconventional gas reservoir by massive hydraulic fracturing which always can be described with the composite model.
ARM Airborne Continuous carbon dioxide measurements
Biraud, Sebastien
2013-03-26
The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.
Alvarez, J.L.; Watson, L.D.
1988-01-21
An apparatus and method for continuously analyzing liquids by creating a supersonic spray which is shaped and sized prior to delivery of the spray to a analysis apparatus. The gas and liquid is sheared into small particles which are of a size and uniformity to form a spray which can be controlled through adjustment of pressures and gas velocity. The spray is shaped by a concentric supplemental flow of gas. 5 figs.
A dryer for rapid response on-line expired gas measurements.
Deno, N S; Kamon, E
1979-06-01
A dryer is described for use in on-line breath-by-breath gas analysis systems. The dryer continuously removes water vapor by condensation and controls the sample gas at 2 degrees C dew-point temperature or 5 Torr water vapor partial pressure. It is designed to operate at gas sampling flow rates from 0.5 to 1 1.min-1. The step-response time for the described system including a Beckman LB-2 CO2 analyzer, sampling tubing, and dryer is 120 ms at 1 l.min-1. The time required for gas samples to transport through the dryer is 105 ms at a gas sampling-flow rate of 1 l.min=1.
NASA Astrophysics Data System (ADS)
Kondrat'eva, O. E.; Roslyakov, P. V.; Burdyukov, D. A.; Khudolei, O. D.; Loktionov, O. A.
2017-10-01
According to Federal Law no. 219-FZ, dated July 21, 2014, all enterprises that have a significant negative impact on the environment shall continuously monitor and account emissions of harmful substances into the atmospheric air. The choice of measuring equipment that is included in continuous emission monitoring and accounting systems (CEM&ASs) is a complex technical problem; in particular, its solution requires a comparative analysis of gas analysis systems; each of these systems has its advantages and disadvantages. In addition, the choice of gas analysis systems for CEM&ASs should be maximally objective and not depend on preferences of separate experts and specialists. The technique of choosing gas analysis equipment that was developed in previous years at Moscow Power Engineering Institute (MPEI) has been analyzed and the applicability of the mathematical tool of a multiple criteria analysis to choose measuring equipment for the continuous emission monitoring and accounting system have been estimated. New approaches to the optimal choice of gas analysis equipment for systems of the continuous monitoring and accounting of harmful emissions from thermal power plants have been proposed, new criteria of evaluation of gas analysis systems have been introduced, and weight coefficients have been determined for these criteria. The results of this study served as a basis for the Preliminary National Standard of the Russian Federation "Best Available Technologies. Automated Systems of Continuous Monitoring and Accounting of Emissions of Harmful (Polluting) Substances from Thermal Power Plants into the Atmospheric Air. Basic Requirements," which was developed by the Moscow Power Engineering Institute, National Research University, in cooperation with the Council of Power Producers and Strategic Electric Power Investors Association and the All-Russia Research Institute for Materials and Technology Standardization.
Further development and testing of the metabolic gas analyzer
NASA Technical Reports Server (NTRS)
1973-01-01
Continued development of a metabolic monitor utilizing a mass spectrometer and digital computer to perform measurements and data reduction, is reported. The device prints-out breath-by-breath values for 02 consumption, C02 production, minute volume and tidal volume. The flow is measured by introduction of a tracer gas to the expired gas stream. Design modifications to reduce pressure drop in the flow splitter to one inch of water at 600 liters/min flow and to extend the range of linear flow measurement to 1000 liters/min are discussed.
Alvarez, Joseph L.; Watson, Lloyd D.
1989-01-01
An apparatus and method for continuously analyzing liquids by creating a supersonic spray which is shaped and sized prior to delivery of the spray to a analysis apparatus. The gas and liquid are mixed in a converging-diverging nozzle where the liquid is sheared into small particles which are of a size and uniformly to form a spray which can be controlled through adjustment of pressures and gas velocity. The spray is shaped by a concentric supplemental flow of gas.
NASA Technical Reports Server (NTRS)
1996-01-01
The Stak-Tracker CEM (Continuous Emission Monitor) Gas Analyzer is an air quality monitor capable of separating the various gases in a bulk exhaust stream and determining the amounts of individual gases present within the stream. The monitor is produced by GE Reuter- Stokes, a subsidiary of GE Corporate Research & Development Center. The Stak-Tracker uses a Langley Research Center software package which measures the concentration of a target gas by determining the degree to which molecules of that gas absorb an infrared beam. The system is environmental-friendly, fast and has relatively low installation and maintenance costs. It is applicable to gas turbines and various industries including glass, paper and cement.
Diffusion limit of Lévy-Lorentz gas is Brownian motion
NASA Astrophysics Data System (ADS)
Magdziarz, Marcin; Szczotka, Wladyslaw
2018-07-01
In this paper we analyze asymptotic behaviour of a stochastic process called Lévy-Lorentz gas. This process is aspecial kind of continuous-time random walk in which walker moves in the fixed environment composed of scattering points. Upon each collision the walker performs a flight to the nearest scattering point. This type of dynamics is observed in Lévy glasses or long quenched polymers. We show that the diffusion limit of Lévy-Lorentz gas with finite mean distance between scattering centers is the standard Brownian motion. Thus, for long times the behaviour of the Lévy-Lorentz gas is close to the diffusive regime.
DOT National Transportation Integrated Search
2008-01-31
The emissions from in-use commercial aircraft engines have been analyzed for selected gas-phase species and particulate characteristics using continuous extractive sampling 1-2 min downwind from operational taxi- and runways at Hartsfield-Jackson Atl...
A True Eddy Accumulation - Eddy Covariance hybrid for measurements of turbulent trace gas fluxes
NASA Astrophysics Data System (ADS)
Siebicke, Lukas
2016-04-01
Eddy covariance (EC) is state-of-the-art in directly and continuously measuring turbulent fluxes of carbon dioxide and water vapor. However, low signal-to-noise ratios, high flow rates and missing or complex gas analyzers limit it's application to few scalars. True eddy accumulation, based on conditional sampling ideas by Desjardins in 1972, requires no fast response analyzers and is therefore potentially applicable to a wider range of scalars. Recently we showed possibly the first successful implementation of True Eddy Accumulation (TEA) measuring net ecosystem exchange of carbon dioxide of a grassland. However, most accumulation systems share the complexity of having to store discrete air samples in physical containers representing entire flux averaging intervals. The current study investigates merging principles of eddy accumulation and eddy covariance, which we here refer to as "true eddy accumulation in transient mode" (TEA-TM). This direct flux method TEA-TM combines true eddy accumulation with continuous sampling. The TEA-TM setup is simpler than discrete accumulation methods while avoiding the need for fast response gas analyzers and high flow rates required for EC. We implemented the proposed TEA-TM method and measured fluxes of carbon dioxide (CO2), methane (CH4) and water vapor (H2O) above a mixed beech forest at the Hainich Fluxnet and ICOS site, Germany, using a G2301 laser spectrometer (Picarro Inc., USA). We further simulated a TEA-TM sampling system using measured high frequency CO2 time series from an open-path gas analyzer. We operated TEA-TM side-by-side with open-, enclosed- and closed-path EC flux systems for CO2, H2O and CH4 (LI-7500, LI-7200, LI-6262, LI-7700, Licor, USA, and FGGA LGR, USA). First results show that TEA-TM CO2 fluxes were similar to EC fluxes. Remaining differences were similar to those between the three eddy covariance setups (open-, enclosed- and closed-path gas analyzers). Measured TEA-TM CO2 fluxes from our physical sampling system closely reproduced dynamics of simulated TEA-TM fluxes. In conclusion this study introduces a new approach to trace gas flux measurements using transient-mode true eddy accumulation. First TEA-TM CO2 fluxes compared favorably with side-by-side EC fluxes, in agreement with our previous experiments comparing discrete TEA to EC. True eddy accumulation has thus potential for measuring turbulent fluxes of a range of atmospheric tracers using slow response analyzers.
NASA Astrophysics Data System (ADS)
Li, Qiangqiang; Ma, Yunfeng; Du, Boying; Wang, Qi; Hu, Qiongqiong; Bian, Yushan
2018-02-01
In this study, continuous kitchen waste fermentation and anaerobic digestion experiments were conducted to analyze the gas production potential, and to study the correlation between gas production rate and volatile fatty acid (VFAs) and its component concentration. During the experiment, the total solid(TS) concentration of the reaction system was increased by adding the kitchen waste, analysis of kitchen waste dry fermentation process to start, run, imbalance and imbalance after recovery and the parameters in the process of realizing the change trend and influencing factors of dry fermentation process, pH and ammonia concentration.
Schwarzer, Patrik; Kuhn, Sven-Olaf; Stracke, Sylvia; Gründling, Matthias; Knigge, Stephan; Selleng, Sixten; Helm, Maximilian; Friesecke, Sigrun; Abel, Peter; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid
2015-09-08
Ionized calcium (iCa) concentration is often used in critical care and measured using blood gas analyzers at the point of care. Controlling and adjusting regional citrate anticoagulation (RCA) for continuous renal replacement therapy (CRRT) involves measuring the iCa concentration in two samples: systemic with physiological iCa concentrations and post filter samples with very low iCa concentrations. However, modern blood gas analyzers are optimized for physiological iCa concentrations which might make them less suitable for measuring low iCa in blood with a high concentration of citrate. We present results of iCa measurements from six different blood gas analyzers and the impact on clinical decisions based on the recommendations of the dialysis' device manufacturer. The iCa concentrations of systemic and post filter samples were measured using six distinct, frequently used blood gas analyzers. We obtained iCa results of 74 systemic and 84 post filter samples from patients undergoing RCA for CRRT at the University Medicine of Greifswald. The systemic samples showed concordant results on all analyzers with median iCa concentrations ranging from 1.07 to 1.16 mmol/L. The medians of iCa concentrations for post filter samples ranged from 0.21 to 0.50 mmol/L. Results of >70% of the post filter samples would lead to major differences in decisions regarding citrate flow depending on the instrument used. Measurements of iCa in post filter samples may give misleading information in monitoring the RCA. Recommendations of the dialysis manufacturer need to be revised. Meanwhile, little weight should be given to post filter iCa. Reference methods for low iCa in whole blood containing citrate should be established.
Continuous high-solids corn liquefaction and fermentation with stripping of ethanol.
Taylor, Frank; Marquez, Marco A; Johnston, David B; Goldberg, Neil M; Hicks, Kevin B
2010-06-01
Removal of ethanol from the fermentor during fermentation can increase productivity and reduce the costs for dewatering the product and coproduct. One approach is to recycle the fermentor contents through a stripping column, where a non-condensable gas removes ethanol to a condenser. Previous research showed that this approach is feasible. Savings of $0.03 per gallon were predicted at 34% corn dry solids. Greater savings were predicted at higher concentration. Now the feasibility has been demonstrated at over 40% corn dry solids, using a continuous corn liquefaction system. A pilot plant, that continuously fed corn meal at more than one bushel (25 kg) per day, was operated for 60 consecutive days, continuously converting 95% of starch and producing 88% of the maximum theoretical yield of ethanol. A computer simulation was used to analyze the results. The fermentation and stripping systems were not significantly affected when the CO(2) stripping gas was partially replaced by nitrogen or air, potentially lowering costs associated with the gas recycle loop. It was concluded that previous estimates of potential cost savings are still valid. (c) 2010. Published by Elsevier Ltd. All rights reserved.
Youn, Woong-Kyu; Kim, Chan-Soo; Hwang, Nong-Moon
2013-10-01
The generation of charged nanoparticles in the gas phase has been continually reported in many chemical vapor deposition processes. Charged silicon nanoparticles in the gas phase were measured using a differential mobility analyzer connected to an atmospheric-pressure chemical vapor deposition reactor at various nitrogen carrier gas flow rates (300-1000 standard cubic centimeter per minute) under typical conditions for silicon deposition at the reactor temperature of 900 degrees C. The carrier gas flow rate affected not only the growth behavior of nanostructures but also the number concentration and size distribution of both negatively and positively charged nanoparticles. As the carrier gas flow rate decreased, the growth behavior changed from films to nanowires, which grew without catalytic metal nanoparticles on a quartz substrate.
An engineering assessment of gas/surface interactions in free-molecular aerodynamics
NASA Technical Reports Server (NTRS)
Knox, E. C.; Liver, Peter A.; Collins, Frank G.
1991-01-01
Data available on the gas/surface interaction (GSI) phenomenon, particularly in the rarefied to near-free-molecular flow regime are collected, categorized, and analyzed with a purpose of developing a GSI model that could be used as a guide to spacecraft designers. The study shows that there are not enough useful data for building a high-confidence GSI model. However, sufficient results are obtained to suggest that continued reliance on the diffuse GSI model is inappropriate, particularly in the near-free-molecular regime.
NASA Technical Reports Server (NTRS)
Williams, K. G.
1974-01-01
The results of a program to develop a prototype gas filter correlation NDIR analyzer capable of providing the required HCl measurement capability, while maintaining an adequate rejection of any other gases anticipated in the atmosphere are presented. Examples of the performance of the prototype analyzer are presented which show an rms noise equivalent concentration of 0.06 ppm of HCl was achieved while maintaining an electronically determined 10% to 90% time response to gas samples of about 2 seconds. No measureable response was observed to CO2, CO, and H2O while maintaining an adequate rejection of the hydrocarbons, for example CH4 and n-hexane. The experiments were performed which demonstrate that the span stability of the HCl gas filter correlation analyzer is unaffected by the presence of water vapor and which support the belief that the incorporation of a relatively open-volume, multiple path sample cell into the instrument would enable ground station as well as airborne measurements of trace quantities of HCl in the ambient atmosphere to be performed.
Characterizing the variation in pH measurements with apheresis platelets.
Moroff, Gary; Seetharaman, Shalini; Kurtz, James; Wagner, Stephen J
2011-11-01
pH measurements of platelet (PLT) components remain a key parameter when assessing how storage and shipping conditions influence the retention of PLT properties. Studies were conducted to characterize variations in pH measured with two pH meters and a blood gas analyzer. Samples were obtained from apheresis PLT units that were stored with or without continuous agitation to measure a range of pH values. pH values were determined with pH meters at room temperature (20-24°C) upon placing of samples in 5-mL sterile polypropylene tubes and with the blood gas analyzer at 37°C upon injection of identical samples, with conversion to 22°C. The calculated coefficient of variation (%CV) of pH measurements using pH meters (n = 10) was 0.43% or less. The %CV values were comparable with different samples having pH values ranging from 6.0 to 7.4. The %CV levels with the blood gas analyzer were comparable to those observed with the pH meters. The difference in the mean pH values for the two pH meters was no greater than 0.10 units, with 9 of 10 samples having differences in values of 0.05 or less; however, greater differences of values (0.1 to 0.2) were observed between pH measured using the blood gas analyzer and pH meters. Our data show good precision and comparability of pH measurements with two pH meters. Differences in pH values were greater on comparison of the blood gas analyzer with the pH meters. © 2011 American Association of Blood Banks.
The 3-D CFD modeling of gas turbine combustor-integral bleed flow interaction
NASA Technical Reports Server (NTRS)
Chen, D. Y.; Reynolds, R. S.
1993-01-01
An advanced 3-D Computational Fluid Dynamics (CFD) model was developed to analyze the flow interaction between a gas turbine combustor and an integral bleed plenum. In this model, the elliptic governing equations of continuity, momentum and the k-e turbulence model were solved on a boundary-fitted, curvilinear, orthogonal grid system. The model was first validated against test data from public literature and then applied to a gas turbine combustor with integral bleed. The model predictions agreed well with data from combustor rig testing. The model predictions also indicated strong flow interaction between the combustor and the integral bleed. Integral bleed flow distribution was found to have a great effect on the pressure distribution around the gas turbine combustor.
CHARACTERIZATION OF THE FINE PARTICLE AND GASEOUS EMISSIONS DURING SCHOOL BUS IDLING
The particulate matter (PM) and gaseous emissions from six diesel school buses were determined over a simulated idling period typical of schools in the northeastern U.S. Testing was conducted for both continuous idle and hot restart conditions using particle and gas analyzers. Th...
Code of Federal Regulations, 2011 CFR
2011-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
Code of Federal Regulations, 2014 CFR
2014-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
Code of Federal Regulations, 2013 CFR
2013-07-01
... stream components, not carbon equivalents. Car-seal means a seal that is placed on a device that is used..., flow inducing devices that transport gas or vapor from an emission point to a control device. A closed...), analyze, and provide a record of process or control system parameters. Continuous record means...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sample bag with a known volume of zero grade air measured by a gas flow meter meeting the performance....121-90 Section 86.121-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the most common...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sample bag with a known volume of zero grade air measured by a gas flow meter meeting the performance....121-90 Section 86.121-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the most common...
Woskov, Paul P.; Cohn, Daniel R.; Titus, Charles H.; Surma, Jeffrey E.
1997-01-01
Microwave-induced plasma for continuous, real time trace element monitoring under harsh and variable conditions. The sensor includes a source of high power microwave energy and a shorted waveguide made of a microwave conductive, high temperature capability refractory material communicating with the source of the microwave energy to generate a plasma. The high power waveguide is constructed to be robust in a hot, hostile environment. It includes an aperture for the passage of gases to be analyzed and a spectrometer is connected to receive light from the plasma. Provision is made for real time in situ calibration. The spectrometer disperses the light, which is then analyzed by a computer. The sensor is capable of making continuous, real time quantitative measurements of desired elements, such as the heavy metals lead and mercury. The invention may be incorporated into a high temperature process device and implemented in situ for example, such as with a DC graphite electrode plasma arc furnace. The invention further provides a system for the elemental analysis of process streams by removing particulate and/or droplet samples therefrom and entraining such samples in the gas flow which passes through the plasma flame. Introduction of and entraining samples in the gas flow may be facilitated by a suction pump, regulating gas flow, gravity or combinations thereof.
International Space Station Major Constituent Analyzer On-Orbit Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Erwin, Phillip M.; Cougar, Tamara; Ulrich, BettyLynn
2017-01-01
The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. The most recent ORU 02 and ORU 08 assemblies in the LAB MCA are operating nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance. Finally, the Node 3 MCA is being brought to an operational configuration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooke, M.; DeRoos, F.; Rising, B.
1984-10-01
The report gives results of an evaluation of the sampling and analysis of ultratrace levels of dibenzodioxins using EPA's recommended source sampling procedures (Modified Method 5 (MM5) train and the Source Assessment Sampling System--SASS). A gas-fired combustion system was used to simulate incineration flue gas, and a precision liquid injection system was designed for the program. The precision liquid injector was used to administer dilute solutions of 1,2,3,4-tetrachlorodibenzo-p-dioxin (1,2,3,4-TCDD) directly into a hot--260C (500F)--flue gas stream. Injections occurred continuously during the sampling episode so that very low gas-phase concentrations of 1,2,3,4-TCDD were continuously mixed with the flue gases. Recoveries weremore » measured for eight burn experiments. For all but one, the recoveries could be considered quantitative, demonstrating efficient collection by the EPA sampling systems. In one study, the components and connecting lines from a sampling device were analyzed separately to show where the 1,2,3,4-TCDD deposited in the train.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, L.R.; Vadie, A.A.
1998-01-20
There are ten injection wells receiving nutrients and twenty producing wells in test patterns are being monitoring for responses. Petrophysical studies of recovered core sample from the 3 newly drilled wells are still in progress. Monthly collection of produced fluids from the test and control wells in all patterns continued with the following tasks being performed: aliphatic profile (gas chromatographic analysis); API gravity and absolute viscosity under reservoir temperature; pH of produced water; surface tension (ST) of produced water (water-air); interfacial tension (IFT) for produced oil-water system; microbiological population; and inorganic analyses (nitrate, phosphate, sulfate, sulfide, chloride, potassium, and hardness).more » Production data on all wells in all patterns continues to be evaluated. Increased gas production that has been noted in some wells could be the result of microbial activity or from previous unswept areas of the reservoir. Samples of gas were collected from selected production wells and analyzed by gas chromatography using a Fisher Model No. 12 Gas Partitioner. The results of analyses from four sets of samples are given.« less
Ontañon, I; Sanz, J; Escudero, A; de Marcos, S; Ferreira, V; Galbán, J
2015-04-03
A homemade flow cell attached to a commercial Gas Chromatograph equipped with a Flame Ionization Detector (FID) has been designed for the continuous monitoring of volatile compounds released during heating edible oils. Analytical parameters such as mass of sample, temperature and flow rates have been optimized and the obtained results have been compared with the corresponding thermographs from standard TG systems. Results show that under optimum conditions, the profiles of volatiles released upon heating are comparable to the profiles of TG curves, suggesting that the FID based system could be an alternative to TGA. Additionally, volatiles have been retained in a Lichrolut EN(®) resin, eluted and analyzed by Gas Chromatography-Mass Spectrometry. In this case, forty five compounds have been identified (acids, alcohols, alkanes, aldehydes, ketones and furans) and compared with the FID signals, working both in air or nitrogen atmosphere. It has been concluded that the oxidative thermal degradation is prevented in the presence of a nitrogen atmosphere. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of various stopping gases for 3He-based position sensitive neutron detectors
NASA Astrophysics Data System (ADS)
Doumas, A.; Smith, G. C.
2012-05-01
A range of solid state, scintillator and gas based detectors are being developed for use at the next generation of high flux neutron facilities. Since gas detectors are expected to continue to play a key role in future specific thermal neutron experiments, a comparison of the performance characteristics of prospective stopping gases is beneficial. Gas detectors typically utilize the reaction 3He(n,p)t to detect thermal neutrons; the 3He gas is used in a mixture containing a particular stopping gas in order to maintain relatively short ranges for the proton and triton pair emitted from the n-3He reaction. Common stopping gases include hydrocarbons (e.g. propane), carbon tetrafluoride, and noble gases such as argon and xenon. For this study, we utilized the Monte Carlo simulation code "Stopping and Range of Ions in Matter" to analyze the expected behavior of argon, xenon, carbon dioxide, difluoroethane and octafluoropropane as stopping gases for thermal neutron detectors. We also compare these findings to our previously analyzed performance of propane, butane and carbon tetrafluoride. A discussion of these gases includes their behavior in terms of proton and triton range, ionization distribution and straggle.
Modeling and Simulation of the Off-gas in an Electric Arc Furnace
NASA Astrophysics Data System (ADS)
Meier, Thomas; Gandt, Karima; Echterhof, Thomas; Pfeifer, Herbert
2017-12-01
The following paper describes an approach to process modeling and simulation of the gas phase in an electric arc furnace (EAF). The work presented represents the continuation of research by Logar, Dovžan, and Škrjanc on modeling the heat and mass transfer and the thermochemistry in an EAF. Due to the lack of off-gas measurements, Logar et al. modeled a simplified gas phase under consideration of five gas components and simplified chemical reactions. The off-gas is one of the main continuously measurable EAF process values and the off-gas flow represents a heat loss up to 30 pct of the entire EAF energy input. Therefore, gas phase modeling offers further development opportunities for future EAF optimization. This paper presents the enhancement of the previous EAF gas phase modeling by the consideration of additional gas components and a more detailed heat and mass transfer modeling. In order to avoid the increase of simulation time due to more complex modeling, the EAF model has been newly implemented to use an efficient numerical solver for ordinary differential equations. Compared to the original model, the chemical components H2, H2O, and CH4 are included in the gas phase and equilibrium reactions are implemented. The results show high levels of similarity between the measured operational data from an industrial scale EAF and the theoretical data from the simulation within a reasonable simulation time. In the future, the dynamic EAF model will be applicable for on- and offline optimizations, e.g., to analyze alternative input materials and mode of operations.
NASA Astrophysics Data System (ADS)
Siebicke, Lukas
2017-04-01
The eddy covariance (EC) method is state-of-the-art in directly measuring vegetation-atmosphere exchange of CO2 and H2O at ecosystem scale. However, the EC method is currently limited to a small number of atmospheric tracers by the lack of suitable fast-response analyzers or poor signal-to-noise ratios. High resource and power demands may further restrict the number of spatial sampling points. True eddy accumulation (TEA) is an alternative method for direct and continuous flux observations. Key advantages are the applicability to a wider range of air constituents such as greenhouse gases, isotopes, volatile organic compounds and aerosols using slow-response analyzers. In contrast to relaxed eddy accumulation (REA), true eddy accumulation (Desjardins, 1977) has the advantage of being a direct method which does not require proxies. True Eddy Accumulation has the potential to overcome above mentioned limitations of eddy covariance but has hardly ever been successfully demonstrated in practice in the past. This study presents flux measurements using an innovative approach to true eddy accumulation by directly, continuously and automatically measuring trace gas fluxes using a flow-through system. We merge high-frequency flux contributions from TEA with low-frequency covariances from the same sensors. We show flux measurements of CO2, CH4 and H2O by TEA and EC above an old-growth forest at the ICOS flux tower site "Hainich" (DE-Hai). We compare and evaluate the performance of the two direct turbulent flux measurement methods eddy covariance and true eddy accumulation using side-by-side trace gas flux observations. We further compare performance of seven instrument complexes, i.e. combinations of sonic anemometers and trace gas analyzers. We compare gas analyzers types of open-path, enclosed-path and closed-path design. We further differentiate data from two gas analysis technologies: infrared gas analysis (IRGA) and laser spectrometry (open path and CRDS closed-path laser spectrometers). We present results of CO2 and H2O fluxes from the following six instruments, i.e. combinations of sonic anemometers/gas analyzers (and methods): METEK-uSonic3/Picarro-G2301 (TEA), METEK-uSonic3/LI-7500 (EC), Gill-R3/LI-6262 (EC), Gill-R3/LI-7200 (EC), Gill-HS/LI-7200 (EC), Gill-R3/LGR-FGGA (EC). Further, we present results of much more difficult to measure CH4 fluxes from the following three instruments, i.e. combinations of sonic anemometers/gas analyzers (and methods): METEK-uSonic3/Picarro-G2301 (TEA), Gill-R3/LI-7700 (EC), Gill-R3/LGR-FGGA (EC). We observed that CO2, CH4 and H2O fluxes from the side-by-side measurements by true eddy accumulation and eddy covariance methods correlated well. Secondly, the difference between the TEA and EC methods using the same sonic anemometer but different gas analyzer was often smaller than the mismatch of the various side-by-side eddy covariance measurements using different sonic anemometers and gas analyzers. Signal-to-noise ratios of CH4 fluxes from the true eddy accumulation system system were superior to both eddy covariance sensors (open-path LI-7700 and closed-path CRDS LGR-FGGA sensors). We conclude that our novel implementation of the true eddy accumulation method demonstrated high signal-to-noise ratios, applicability to slow-response gas analyzers, small power consumption and direct proxy-free ecosystem-scale trace gas flux measurements of CO2, CH4 and H2O. The current results suggest that true eddy accumulation would be suitable and should be applied as the method-of-choice for direct flux measurements of a large number of atmospheric constituents beyond CO2 and H2O, including isotopes, aerosols, volatile organic compounds and other trace gases for which eddy covariance might not be a viable alternative. We will further develop true eddy accumulation as a novel approach using multiplexed systems for spatially distributed flux measurements.
Residual gas analysis for long-pulse, advanced tokamak operation.
Klepper, C C; Hillis, D L; Bucalossi, J; Douai, D; Oddon, P; Vartanian, S; Colas, L; Manenc, L; Pégourié, B
2010-10-01
A shielded residual gas analyzer (RGA) system on Tore Supra can function during plasma operation and is set up to monitor the composition of the neutral gas in one of the pumping ducts of the toroidal pumped limited. This "diagnostic RGA" has been used in long-pulse (up to 6 min) discharges for continuous monitoring of up to 15 masses simultaneously. Comparison of the RGA-measured evolution of the H(2)/D(2) isotopic ratio in the exhaust gas to that measured by an energetic neutral particle analyzer in the plasma core provides a way to monitor the evolution of particle balance. RGA monitoring of corrective H(2) injection to maintain proper minority heating is providing a database for improved ion cyclotron resonance heating, potentially with RGA-base feedback control. In very long pulses (>4 min) absence of significant changes in the RGA-monitored, hydrocarbon particle pressures is an indication of proper operation of the actively cooled, carbon-based plasma facing components. Also H(2) could increase due to thermodesorption of overheated plasma facing components.
2015-04-22
ceased. Oxygen concentration was continuously measured with a fast laser diode oxygen analyzer (O2CAP, Oxigraf, Inc., Mountain View, CA) throughout the...duration of operation. The output generated from the COGs was analyzed by a gas mass spectrometer (QGA model HAS 301, Hiden Analytical, Livonia, MI...throughout the range of bolus volumes with each device at respiratory rates of 20 and 30 breaths /min with each bolus setting. Data were recorded every
Fuel flexibility via real-time Raman fuel-gas analysis for turbine system control
NASA Astrophysics Data System (ADS)
Buric, M.; Woodruff, S.; Chorpening, B.; Tucker, D.
2015-06-01
The modern energy production base in the U.S. is increasingly incorporating opportunity fuels such as biogas, coalbed methane, coal syngas, solar-derived hydrogen, and others. In many cases, suppliers operate turbine-based generation systems to efficiently utilize these diverse fuels. Unfortunately, turbine engines are difficult to control given the varying energy content of these fuels, combined with the need for a backup natural gas supply to provide continuous operation. Here, we study the use of a specially designed Raman Gas Analyzer based on capillary waveguide technology with sub-second response time for turbine control applications. The NETL Raman Gas Analyzer utilizes a low-power visible pump laser, and a capillary waveguide gas-cell to integrate large spontaneous Raman signals, and fast gas-transfer piping to facilitate quick measurements of fuel-gas components. A U.S. Department of Energy turbine facility known as HYPER (hybrid performance system) serves as a platform for apriori fuel composition measurements for turbine speed or power control. A fuel-dilution system is used to simulate a compositional upset while simultaneously measuring the resultant fuel composition and turbine response functions in real-time. The feasibility and efficacy of system control using the spontaneous Raman-based measurement system is then explored with the goal of illustrating the ability to control a turbine system using available fuel composition as an input process variable.
International Space Station Major Constituent Analyzer On-orbit Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Erwin, Phillip M.; Wiedemann, Rachel; Matty, Chris
2016-01-01
The Major Constituent Analyzer (MCA) is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. The most recent ORU 02 and ORU 08 assemblies are operating nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance. Additionally, testing is underway to evaluate the capacity of the MCA to analyze ammonia. Finally, plans are being made to bring the second MCA on ISS to an operational configuration.
NOAA Mobile Laboratory Measures Oil and Gas Emissions
NASA Astrophysics Data System (ADS)
Kofler, J. D.; Petron, G.; Dube, W. P.; Edwards, P. M.; Brown, S. S.; Geiger, F.; Patrick, L.; Crepinsek, S.; Chen, H.; Miller, B. R.; Montzka, S. A.; Lang, P. M.; Newberger, T.; Higgs, J. A.; Sweeney, C.; Guenther, D.; Karion, A.; Wolter, S.; Williams, J.; Jordan, A.; Tans, P. P.; Schnell, R. C.
2012-12-01
A van capable of continuous real time measurements of CH4 , CO2, CO, Water Vapor, Ozone, NO, NO2, Volatile Organic Compounds VOCs including aromatics and other traces gases was driven in the oil and gas fields of the Uintah Basin in northeastern Utah. Compressor Stations, processing plants, oil and gas well heads. Separators, condensate tanks, evaporation pond disposal facilities, holding tanks, hydraulic fracturing sites, gas pipelines and more were studied using the van. The mobile measurements provide a powerful tool to get to the source of the emissions and reveal the unique chemical signature of each of the stages and components of oil and gas production as well as the overall basin and background gas concentrations. In addition to a suite of gas analyzers, the van includes a meteorological system (temperature, humidity, and wind speed and direction), GPS tracking, flask sampling system and a batter power system. Aspects of the vans hardware, sampling methods and operations are discussed along with a few highlights of the measurements.
Bian, Xu; Zhang, Yu; Li, Yibo; Gong, Xiaoyue; Jin, Shijiu
2015-01-01
This paper proposes a time-space domain correlation-based method for gas leakage detection and location. It acquires the propagated signal on the skin of the plate by using a piezoelectric acoustic emission (AE) sensor array. The signal generated from the gas leakage hole (which diameter is less than 2 mm) is time continuous. By collecting and analyzing signals from different sensors’ positions in the array, the correlation among those signals in the time-space domain can be achieved. Then, the directional relationship between the sensor array and the leakage source can be calculated. The method successfully solves the real-time orientation problem of continuous ultrasonic signals generated from leakage sources (the orientation time is about 15 s once), and acquires high accuracy location information of leakage sources by the combination of multiple sets of orientation results. According to the experimental results, the mean value of the location absolute error is 5.83 mm on a one square meter plate, and the maximum location error is generally within a ±10 mm interval. Meanwhile, the error variance is less than 20.17. PMID:25860070
Bian, Xu; Zhang, Yu; Li, Yibo; Gong, Xiaoyue; Jin, Shijiu
2015-04-09
This paper proposes a time-space domain correlation-based method for gas leakage detection and location. It acquires the propagated signal on the skin of the plate by using a piezoelectric acoustic emission (AE) sensor array. The signal generated from the gas leakage hole (which diameter is less than 2 mm) is time continuous. By collecting and analyzing signals from different sensors' positions in the array, the correlation among those signals in the time-space domain can be achieved. Then, the directional relationship between the sensor array and the leakage source can be calculated. The method successfully solves the real-time orientation problem of continuous ultrasonic signals generated from leakage sources (the orientation time is about 15 s once), and acquires high accuracy location information of leakage sources by the combination of multiple sets of orientation results. According to the experimental results, the mean value of the location absolute error is 5.83 mm on a one square meter plate, and the maximum location error is generally within a ±10 mm interval. Meanwhile, the error variance is less than 20.17.
Monte Carlo Uncertainty Quantification for an Unattended Enrichment Monitor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarman, Kenneth D.; Smith, Leon E.; Wittman, Richard S.
As a case study for uncertainty analysis, we consider a model flow monitor for measuring enrichment in gas centrifuge enrichment plants (GCEPs) that could provide continuous monitoring of all declared gas flow and provide high-accuracy gas enrichment estimates as a function of time. The monitor system could include NaI(Tl) gamma-ray spectrometers, a pressure signal-sharing device to be installed on an operator\\rq{}s pressure gauge or a dedicated inspector pressure sensor, and temperature sensors attached to the outside of the header pipe, to provide pressure, temperature, and gamma-ray spectra measurements of UFmore » $$_6$$ gas flow through unit header pipes. Our study builds on previous modeling and analysis methods development for enrichment monitor concepts and a software tool that was developed at Oak Ridge National Laboratory to generate and analyze synthetic data.« less
NASA Astrophysics Data System (ADS)
Cui, Xiaojuan; Dong, Fengzhong; Sigrist, Markus W.; Zhang, Zhirong; Wu, Bian; Xia, Hua; Pang, Tao; Sun, Pengshuai; Fertein, Eric; Chen, Weidong
2016-10-01
Effective line intensities of P branch transitions of trans-nitrous acid (HONO) in the ν3 H-O-N bending mode near 1255 cm-1 have been determined by scaling measured HONO absorption intensities by continuous-wave quantum cascade laser absorption spectroscopy to reference values. Gaseous HONO samples were synthetized in the laboratory using the reaction of H2SO4 and NaNO2 solutions and the heterogeneous formation on surfaces in the presence of ambient water vapor and NO2 gas in a sealed gas sampling bag. The quantification of HONO was performed using a denuder associated with a NOx analyzer. Observed absorption line strengths for the trans conformer are found to be by a factor of approximately 1.17 higher than previously reported line strengths.
Wamsley, Paula R.; Weimer, Carl S.; Nelson, Loren D.; O'Brien, Martin J.
2003-01-01
An oil and gas exploration system and method for land and airborne operations, the system and method used for locating subsurface hydrocarbon deposits based upon a remote detection of trace amounts of gases in the atmosphere. The detection of one or more target gases in the atmosphere is used to indicate a possible subsurface oil and gas deposit. By mapping a plurality of gas targets over a selected survey area, the survey area can be analyzed for measurable concentration anomalies. The anomalies are interpreted along with other exploration data to evaluate the value of an underground deposit. The system includes a differential absorption lidar (DIAL) system with a spectroscopic grade laser light and a light detector. The laser light is continuously tunable in a mid-infrared range, 2 to 5 micrometers, for choosing appropriate wavelengths to measure different gases and avoid absorption bands of interference gases. The laser light has sufficient optical energy to measure atmospheric concentrations of a gas over a path as long as a mile and greater. The detection of the gas is based on optical absorption measurements at specific wavelengths in the open atmosphere. Light that is detected using the light detector contains an absorption signature acquired as the light travels through the atmosphere from the laser source and back to the light detector. The absorption signature of each gas is processed and then analyzed to determine if a potential anomaly exists.
International Space Station Major Constituent Analyzer On-Orbit Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Erwin, Phillip M.; Thoresen, Souzan; Wiedemann, Rachel; Matty, Chris
2015-01-01
The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. Improvements to ion pump operation and ion source tuning have improved lifetime performance of the current ORU 02 design. The most recent ORU 02 analyzer assemblies, as well as ORU 08, have operated nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance and logistical support. Monitoring several key parameters provides the capacity to monitor ORU health and properly anticipate end of life.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, He; Yuan, Ping; Cen, Jian-Yong
2014-03-15
A cloud-to-ground lightning with six return strokes has been recorded with a slit-less spectrograph in Qinghai province. According to the spectra of return strokes without continuous current, the electron density, the channel temperature, and the gas pressure have been calculated. Then, the correlativity of these parameters has been analyzed. The results indicate that the total intensity of spectra is positive correlated to the intensity of spectral line, they both decrease with time rapidly; furthermore, the channel temperature and the gas pressure decrease with time slowly in the similar trends.
2015 Volcanic activity in Alaska—Summary of events and response of the Alaska Volcano Observatory
Dixon, James P.; Cameron, Cheryl E.; Iezzi, Alexandra M.; Wallace, Kristi
2017-09-28
The Alaska Volcano Observatory (AVO) responded to eruptions, volcanic unrest or suspected unrest, and seismic events at 14 volcanic centers in Alaska during 2015. The most notable volcanic activity consisted of continuing intermittent ash eruptions from Cleveland and Shishaldin volcanoes in the Aleutian Islands. Two eruptive episodes, at Veniaminof and Pavlof, on the Alaska Peninsula ended in 2015. During 2015, AVO re-established the seismograph network at Aniakchak, installed six new broadband seismometers throughout the Aleutian Islands, and added a Multiple component Gas Analyzer System (MultiGAS) station on Augustine.
Design development and test: Two-gas atmosphere control subsystem
NASA Technical Reports Server (NTRS)
Jackson, J. K.
1974-01-01
An atmosphere control subsystem (ACS) was developed for NASA-IBJSC which is designed to measure the major atmospheric constituents in the manned cabin of the space shuttle orbiter and control the addition of oxygen and nitrogen to maintain the partial pressures of these gases within very close limits. The ACS includes a mass spectrometer sensor (MSS) which analyzes the atmosphere of a shuttle vehicle pressurized cabin, and an electronic control assembly (ECA). The MSS was built and tested to meet the requirements for flight equipment for the M-171 Metabolic Analyzer experiment for the Skylab flight program. The instrument analyzes an atmospheric gas sample and produces continuous 0-5 vdc analog signals proportional to the partial pressures of H2, O2, N2, H2O, CO2 and total hydrocarbons having a m/e ratio between 50 and 120. It accepts signals from the MSS proportional to the partial pressures of N2 and O2 and controls the supply of these gases to the closed cabin.
High-quality eddy-covariance CO2 budgets under cold climate conditions
NASA Astrophysics Data System (ADS)
Kittler, Fanny; Eugster, Werner; Foken, Thomas; Heimann, Martin; Kolle, Olaf; Göckede, Mathias
2017-08-01
This study aimed at quantifying potential negative effects of instrument heating to improve eddy-covariance flux data quality in cold environments. Our overarching objective was to minimize heating-related bias in annual CO2 budgets from an Arctic permafrost system. We used continuous eddy-covariance measurements covering three full years within an Arctic permafrost ecosystem with parallel sonic anemometers operation with activated heating and without heating as well as parallel operation of open- and closed-path gas analyzers, the latter serving as a reference. Our results demonstrate that the sonic anemometer heating has a direct effect on temperature measurements while the turbulent wind field is not affected. As a consequence, fluxes of sensible heat are increased by an average 5 W m-2 with activated heating, while no direct effect on other scalar fluxes was observed. However, the biased measurements in sensible heat fluxes can have an indirect effect on the CO2 fluxes in case they are used as input for a density-flux WPL correction of an open-path gas analyzer. Evaluating the self-heating effect of the open-path gas analyzer by comparing CO2 flux measurements between open- and closed-path gas analyzers, we found systematically higher CO2 uptake recorded with the open-path sensor, leading to a cumulative annual offset of 96 gC m-2, which was not only the result of the cold winter season but also due to substantial self-heating effects during summer. With an inclined sensor mounting, only a fraction of the self-heating correction for vertically mounted instruments is required.
Resource conservation program in terms of Vostokgazprom environmental policy
NASA Astrophysics Data System (ADS)
Tsibulnikova, M. R.; Nadyumov, S. V.; Adam, A. M.; Korotchenko, T. V.
2016-09-01
The article examines a number of key areas of environmental policy of Vostokgazprom. The Associated Petroleum Gas program is an important step within the resource conservation and environmental protection framework. In addition, the company undertakes the extensive work on emergency response programs, and carries out continuous protection of the subsurface and control over environmental safety in all production sites. Vostokgazprom continuously modernizes the basic industrial facilities and invests money in new projects. The study analyzes the steps being taken by the company within the energy saving policy that leads to significant costs cut.
2014-12-04
is determined with an on-line, continuous NDIR analyzer and O2 is measured using an electrochemical oxygen sensor . 8 3.1.2 Modelling Approach...hydrocarbons were discussed. Additionally, the possibility to extend the reach of JetSurF model and apply it for models of soot formation in gas turbine engines was addressed.
Charpentier, Ronald R.; Cook, Troy A.
2013-01-01
Over the last decade, oil and gas well productivities were estimated using decline-curve analysis for thousands of wells as part of U.S. Geological Survey (USGS) studies of continuous (unconventional) oil and gas resources in the United States. The estimated ultimate recoveries (EURs) of these wells show great variability that was analyzed at three scales: within an assessment unit (AU), among AUs of similar reservoir type, and among groups of AUs with different reservoir types. Within a particular oil or gas AU (such as the Barnett Shale), EURs vary by about two orders of magnitude between the most productive wells and the least productive ones (excluding those that are dry and abandoned). The distributions of EURs are highly skewed, with most of the wells in the lower part of the range. Continuous AUs were divided into four categories based on reservoir type and major commodity (oil or gas): coalbed gas, shale gas, other low-permeability gas AUs (such as tight sands), and low-permeability oil AUs. Within each of these categories, there is great variability from AU to AU, as shown by plots of multiple EUR distributions. Comparing the means of each distribution within a category shows that the means themselves have a skewed distribution, with a range of approximately one to two orders of magnitude. A comparison of the three gas categories (coalbed gas, shale gas, and other low-permeability gas AUs) shows large overlap in the ranges of EUR distributions. Generally, coalbed gas AUs have lower EUR distributions, shale gas AUs have intermediate sizes, and the other low-permeability gas AUs have higher EUR distributions. The plot of EUR distributions for each category shows the range of variation among developed AUs in an appropriate context for viewing the historical development within a particular AU. The Barnett Shale is used as an example to demonstrate that dividing wells into groups by time allows one to see the changes in EUR distribution. Subdivision into groups can also be done by vertical versus horizontal wells, by length of horizontal completion, by distance to closest previously drilled well, by thickness of reservoir interval, or by any other variable for which one has or can calculate values for each well. The resulting plots show how one can subdivide the total range of productivity in shale-gas wells into smaller subsets that are more appropriate for use as analogs.
Atmospheric Carbon Dioxide Record from Mauna Loa (1958-2008)
Keeling, R. F. [Scripps Institution of Oceanography, University of California, La Jolla, California; Piper, S. C. [Scripps Institution of Oceanography, University of California, La Jolla, California; Bollenbacher, A. F. [Scripps Institution of Oceanography, University of California, La Jolla, California; Walker, J. S. [Scripps Institution of Oceanography, University of California, La Jolla, California
2009-02-01
Air samples at Mauna Loa are collected continuously from air intakes at the top of four 7-m towers and one 27-m tower. Four air samples are collected each hour for the purpose of determining the CO2 concentration. Determinations of CO2 are made by using a Siemens Ultramat 3 nondispersive infrared gas analyzer with a water vapor freeze trap. This analyzer registers the concentration of CO2 in a stream of air flowing at ~0.5 L/min. Every 30 minutes, the flow is replaced by a stream of calibrating gas or "working reference gas". In December 1983, CO2-in-N2 calibration gases were replaced with the currently used CO2-in-air calibration gases. These calibration gases and other reference gases are compared periodically to determine the instrument sensitivity and to check for possible contamination in the air-handling system. These reference gases are themselves calibrated against specific standard gases whose CO2 concentrations are determined manometrically. Greater details about the sampling methods at Mauna Loa are given in Keeling et al. (1982) and Keeling et al. (2002).
21 CFR 868.1640 - Helium gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Helium gas analyzer. 868.1640 Section 868.1640...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1640 Helium gas analyzer. (a) Identification. A helium gas analyzer is a device intended to measure the concentration of helium in a gas...
21 CFR 868.1640 - Helium gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Helium gas analyzer. 868.1640 Section 868.1640...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1640 Helium gas analyzer. (a) Identification. A helium gas analyzer is a device intended to measure the concentration of helium in a gas...
Development of a wet vapor homogeneous liquid metal MHD power system
NASA Astrophysics Data System (ADS)
1989-04-01
During the period covered by this report (October 1988 to March 1989), the following work was done: the mixing stream condensation process was analyzed, and a theoretical model for simulating this process was modified. A parametric study is being conducted at the present time; the separation processes were analyzed; and the experimental system was specified and its design is at present in an advanced stage. The mixing stream condensation process was analyzed. For the parameters defined in the SOW of this project the process was found to be a mist flow direct contact condensation, where the hot gas mixture consisting of inert gas and vapor is the continuous phase, and the subcooled liquid on which the vapor is condensed if the droplets dispersed phase. Two possibilities of creating the mist flow were considered. The first, injecting the cold Liquid Metal (LM) into the Mixing Streams Condenser (MSC) entrance as a jet and breaking it into LM fragments and the fragments into droplets by momentum transfer breakup mechanism. The second, atomizing the cooled LM stream into little droplets (approximately 100 micrometers in diameter) and accelerating them by the gas. The second possibility was preferred due to its much higher heat and mass transfer surface and coefficients relative to the first one.
Apparatus for diffusion separation
Nierenberg, William A.; Pontius, Rex B.
1976-08-10
1. The method of testing the separation efficiency of porous permeable membranes which comprises causing a stream of a gaseous mixture to flow into contact with one face of a finely porous permeable membrane under such conditions that a major fraction of the mixture diffuses through the membrane, maintaining a rectangular cross section of the gaseous stream so flowing past said membrane, continuously recirculating the gas that diffuses through said membrane and continuously withdrawing the gas that does not diffuse through said membrane and maintaining the volume of said recirculating gas constant by continuously introducing into said continuously recirculating gas stream a mass of gas equivalent to that which is continuously withdrawn from said gas stream and comparing the concentrations of the light component in the entering gas, the withdrawn gas and the recirculated gas in order to determine the efficiency of said membrane.
Desertification of the peritoneum by thin-film evaporation during laparoscopy.
Ott, Douglas E
2003-01-01
To assess the effects of gas flow during insufflation on peritoneal fluid and peritoneal tissue regarding transient thermal behavior and thin-film evaporation. The effects of laparoscopic gas on peritoneal cell desiccation and peritoneal fluid thin-film evaporation were analyzed. Measurment of tissue and peritoneal fluid and analysis of gas flow dynamics during laparoscopy. High-velocity gas interface conditions during laparoscopic gas insufflation result in peritoneal surface temperature and decreases up to 20 degrees C/second due to rapid thin-film evaporation of the peritoneal fluid. Evaporation of the thin film of peritoneal fluid extends quickly to the peritoneal cell membrane, causing peritoneal cell desiccation, internal cytoplasmic stress, and disruption of the cell membrane, resulting in loss of peritoneal surface continuity and integrity. Changing the gas conditions to 35 degrees C and 95% humidity maintains normal peritoneal fluid thin-film characteristics, cellular integrity, and prevents evaporative losses. Cold, dry gas and the characteristics of the laparoscopic gas delivery apparatus cause local peritoneal damaging alterations by high-velocity gas flow with extremely dry gas, creating extreme arid surface conditions, rapid evaporative and hydrological changes, tissue desiccation, and peritoneal fluid alterations that contribute to the process of desertification and thin-film evaporation. Peritoneal desertification is preventable by preconditioning the gas to 35 degrees C and 95% humidity.
Process feasibility study in support of silicon material task 1
NASA Technical Reports Server (NTRS)
Li, K. Y.; Hansen, K. C.; Yaws, C. L.
1978-01-01
Process system properties are analyzed for materials involved in the alternate processes under consideration for solar cell grade silicon. The following property data are reported for trichlorosilane: critical constants, vapor pressure, heat of vaporization, gas heat capacity, liquid heat capacity, density, surface tension, viscosity, thermal conductivity, heat of formation, and Gibb's free energy of formation. Work continued on the measurement of gas viscosity values of silicon source materials. Gas phase viscosity values for silicon tetrafluoride between 40 C and 200 C were experimentally determined. Major efforts were expended on completion of the preliminary economic analysis of the silane process. Cost, sensitivity and profitability analysis results are presented based on a preliminary process design of a plant to produce 1,000 metric tons/year of silicon by the revised process.
Kleeblatt, Juliane; Schubert, Jochen K; Zimmermann, Ralf
2015-02-03
A fast detection method to analyze gaseous organic compounds in complex gas mixtures was developed, using a needle trap device (NTD) in conjunction with thermal-desorption photoionization time-of-flight mass spectrometry (TD-PI-TOFMS). The mass spectrometer was coupled via a deactivated fused silica capillary to an injector of a gas chromatograph. In the hot injector, the analytes collected on the NTD were thermally desorbed and directly transferred to the PI-TOFMS ion source. The molecules are softly ionized either by single photon ionization (SPI, 118 nm) or by resonance enhanced multiphoton ionization (REMPI, 266 nm), and the molecular ion signals are detected in the TOF mass analyzer. Analyte desorption and the subsequent PI-TOFMS detection step only lasts ten seconds. The specific selectivity of REMPI (i.e., aromatic compounds) and universal ionization characteristics render PI-MS as a promising detection system. As a first demonstrative application, the alveolar phase breath gas of healthy, nonsmoking subjects was sampled on NTDs. While smaller organic compounds such as acetone, acetaldehyde, isoprene, or cysteamine can be detected in the breath gas with SPI, REMPI depicts the aromatic substances phenol and indole at 266 nm. In the breath gas of a healthy, smoking male subject, several xenobiotic substances such as benzene, toluene, styrene, and ethylbenzene can be found as well. Furthermore, the NTD-REMPI-TOFMS setup was tested for breath gas taken from a mechanically ventilated pig under continuous intravenous propofol (2,6-diisopropylphenol, narcotic drug) infusion.
NASA Astrophysics Data System (ADS)
Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.
2011-11-01
Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruise routes: from Japan to Oceania, the United States, Canada, and Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 years. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.
NASA Astrophysics Data System (ADS)
Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.
2011-07-01
Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruising routes: from Japan to Oceania, from Japan to the United States, from Japan to Canada, and from Japan to Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards (CO balanced with purified air at ppmv levels) during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 yr. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.
Bian, Xu; Li, Yibo; Feng, Hao; Wang, Jiaqiang; Qi, Lei; Jin, Shijiu
2015-01-01
This paper proposes a continuous leakage location method based on the ultrasonic array sensor, which is specific to continuous gas leakage in a pressure container with an integral stiffener. This method collects the ultrasonic signals generated from the leakage hole through the piezoelectric ultrasonic sensor array, and analyzes the space-time correlation of every collected signal in the array. Meanwhile, it combines with the method of frequency compensation and superposition in time domain (SITD), based on the acoustic characteristics of the stiffener, to obtain a high-accuracy location result on the stiffener wall. According to the experimental results, the method successfully solves the orientation problem concerning continuous ultrasonic signals generated from leakage sources, and acquires high accuracy location information on the leakage source using a combination of multiple sets of orienting results. The mean value of location absolute error is 13.51 mm on the one-square-meter plate with an integral stiffener (4 mm width; 20 mm height; 197 mm spacing), and the maximum location absolute error is generally within a ±25 mm interval. PMID:26404316
Incorporating the gas analyzer response time in gas exchange computations.
Mitchell, R R
1979-11-01
A simple method for including the gas analyzer response time in the breath-by-breath computation of gas exchange rates is described. The method uses a difference equation form of a model for the gas analyzer in the computation of oxygen uptake and carbon dioxide production and avoids a numerical differentiation required to correct the gas fraction wave forms. The effect of not accounting for analyzer response time is shown to be a 20% underestimation in gas exchange rate. The present method accurately measures gas exchange rate, is relatively insensitive to measurement errors in the analyzer time constant, and does not significantly increase the computation time.
Viscous-shock-layer analysis of hypersonic flows over long slender vehicles. Ph.D. Thesis, 1988
NASA Technical Reports Server (NTRS)
Lee, Kam-Pui; Gupta, Roop N.
1992-01-01
An efficient and accurate method for solving the viscous shock layer equations for hypersonic flows over long slender bodies is presented. The two first order equations, continuity and normal momentum, are solved simultaneously as a coupled set. The flow conditions included are from high Reynolds numbers at low altitudes to low Reynolds numbers at high altitudes. For high Reynolds number flows, both chemical nonequilibrium and perfect gas cases are analyzed with surface catalytic effects and different turbulence models, respectively. At low Reynolds number flow conditions, corrected slip models are implemented with perfect gas case. Detailed comparisons are included with other predictions and experimental data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... cyclic analyzers, the response time test shall include one cycle. 5.3.2Introduce a zero concentration of... operation when the pollutant concentration at the time for the measurement is zero. 1.6Calibration Drift...%, and 30%) calibration gas mixture. 3. Zero Drift (2-hours) a ≤2 percent of emission standard. 4. Zero...
Elemental Abundances in the Intracluster Gas and the Hot Galactic Coronae in Cluster A194
NASA Technical Reports Server (NTRS)
Forman, William R.
1997-01-01
We have completed the analysis of observations of the Coma cluster and are continuing analysis of A1367 both of which are shown to be merging clusters. Also, we are analyzing observations of the Centaurus cluster which we see as a merger based in both its temperature and surface brightness distributions. Attachment: Another collision for the coma cluster.
Ridgley, J.L.; Condon, S.M.; Hatch, J.R.
2013-01-01
Eight assessment units were defined in the Mancos-Menefee Composite TPS. Of the eight assessment units, four were assessed as conventional oil or gas accumulations and four as continuous-type accumulations. The conventional assessment units are Dakota-Greenhorn Conventional Oil and Gas Assessment Unit (AU), Gallup Sandstone Conventional Oil and Gas AU, Mancos Sandstones Conventional Oil AU, and the Mesaverde Updip Conventional Oil AU. Continuous-type assessments are Dakota-Greenhorn Continuous Gas AU, Mancos Sandstones Continuous Gas AU, Mesaverde Central-Basin Continuous Gas AU, and Menefee Coalbed Gas AU. The Mesaverde Updip Conventional AU was not quantitatively assessed for undiscovered oil and gas resources, because the producing oil fields were smaller than the 0.5 million barrel cutoff, and the potential of finding fields above this cutoff was considered to be low. Total oil resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 16.78 million barrels. Most of this resource will come from reservoirs in the Mancos Sandstones Oil AU. Gas resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 11.11 trillion cubic feet of gas (TCFG). Of this amount, 11.03 TCFG will come from continuous gas accumulations; the remainder will be gas associated with oil in conventional accumulations.Total natural gas liquids (NGL) that have the potential for additions to reserves in the next 30 years are estimated at a mean of 99.86 million barrels. Of this amount, 96.95 million barrels will come from the continuous gas assessment units, and 78.3 percent of this potential resource will come from the Mancos Sandstones Continuous Gas AU.
Atomizing, continuous, water monitoring module
Thompson, C.V.; Wise, M.B.
1997-07-08
A system for continuously analyzing volatile constituents of a liquid is described. The system contains a pump for continuously pumping the liquid to be tested at a predetermined flow rate into an extracting container through a liquid directing tube having an orifice at one end and positioned to direct the liquid into the extracting container at a flow rate sufficient to atomize the liquid within the extracting container. A continuous supply of helium carrier gas at a predetermined flow rate is directed through a tube into the extracting container and co-mingled with the atomized liquid to extract the volatile constituents contained within the atomized liquid. The helium containing the extracted volatile constituents flows out of the extracting container into a mass spectrometer for an analysis of the volatile constituents of the liquid. 3 figs.
Atomizing, continuous, water monitoring module
Thompson, Cyril V.; Wise, Marcus B.
1997-01-01
A system for continuously analyzing volatile constituents of a liquid is described. The system contains a pump for continuously pumping the liquid to be tested at a predetermined flow rate into an extracting container through a liquid directing tube having an orifice at one end and positioned to direct the liquid into the extracting container at a flow rate sufficient to atomize the liquid within the extracting container. A continuous supply of helium carrier gas at a predetermined flow rate is directed through a tube into the extracting container and co-mingled with the atomized liquid to extract the volatile constituents contained within the atomized liquid. The helium containing the extracted volatile constituents flows out of the extracting container into a mass spectrometer for an analysis of the volatile constituents of the liquid.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.613A-0 Limitations on percentage depletion in the case of oil and gas wells; table of contents...) Natural gas. (c) Regulated natural gas. (d) Natural gas sold under fixed contract. (e) Qualified natural...
Applying probabilistic well-performance parameters to assessments of shale-gas resources
Charpentier, Ronald R.; Cook, Troy
2010-01-01
In assessing continuous oil and gas resources, such as shale gas, it is important to describe not only the ultimately producible volumes, but also the expected well performance. This description is critical to any cost analysis or production scheduling. A probabilistic approach facilitates (1) the inclusion of variability in well performance within a continuous accumulation, and (2) the use of data from developed accumulations as analogs for the assessment of undeveloped accumulations. In assessing continuous oil and gas resources of the United States, the U.S. Geological Survey analyzed production data from many shale-gas accumulations. Analyses of four of these accumulations (the Barnett, Woodford, Fayetteville, and Haynesville shales) are presented here as examples of the variability of well performance. For example, the distribution of initial monthly production rates for Barnett vertical wells shows a noticeable change with time, first increasing because of improved completion practices, then decreasing from a combination of decreased reservoir pressure (in infill wells) and drilling in less productive areas. Within a partially developed accumulation, historical production data from that accumulation can be used to estimate production characteristics of undrilled areas. An understanding of the probabilistic relations between variables, such as between initial production and decline rates, can improve estimates of ultimate production. Time trends or spatial trends in production data can be clarified by plots and maps. The data can also be divided into subsets depending on well-drilling or well-completion techniques, such as vertical in relation to horizontal wells. For hypothetical or lightly developed accumulations, one can either make comparisons to a specific well-developed accumulation or to the entire range of available developed accumulations. Comparison of the distributions of initial monthly production rates of the four shale-gas accumulations that were studied shows substantial overlap. However, because of differences in decline rates among them, the resulting estimated ultimate recovery (EUR) distributions are considerably different.
Chapter 4: The Cretaceous-Lower Tertiary Composite Total Petroleum System, Wind River Basin, Wyoming
Johnson, R.C.; Finn, Thomas M.; Kirschbaum, Mark A.; Roberts, Stephen B.; Roberts, Laura N.R.; Cook, Troy; Taylor, David J.
2007-01-01
The Cretaceous-Lower Tertiary Composite Total Petroleum System (TPS) of the Wind River Basin Province includes all strata from the base of the Lower Cretaceous Cloverly Formation to the base of the Waltman Shale Member of the Paleocene age Fort Union Formation and, where the Waltman is absent, includes strata as young as the Eocene Wind River Formation. Locally, Cretaceous-sourced gas migrated into strata as old as the Mississippian Madison Limestone, and in these areas the TPS extends stratigraphically downward to include these reservoirs. The extensive vertical migration of gases in highly fractured areas of the Wind River Basin led to the commingling of gases from several Upper Cretaceous and lower Tertiary sources, thus only two petroleum systems are recognized in these rocks, the Cretaceous-Lower Tertiary Composite TPS, the subject of this report, and the Waltman Shale TPS described by Roberts and others (Chapter 5, this CD-ROM). The Cretaceous-lower Tertiary Composite TPS was subdivided into (1) seven continuous gas assessment units (AU): (a) Frontier-Muddy Continuous Gas AU, (b) Cody Sandstone Continuous Gas AU, (c) Mesaverde--Meeteetse Sandstone Gas AU, (d) Lance-Fort Union Sandstone Gas AU, (e) Mesaverde Coalbed Gas AU, (f) Meeteetse Coalbed Gas AU, and (g) Fort Union Coalbed Gas AU; (2) one continuous oil assessement unit--- Cody Fractured Shale Continuous Oil AU; and (3) one conventional assessment Unit--- Cretaceous-Tertiary Conventional Oil and Gas AU. Estimates of undiscovered resources having the potential for additions to reserves were made for all but the Cody Fractured Shale Continuous Oil AU, which is considered hypothetical and was not quantitively assessed. The mean estimate of the total oil is 41.99 million barrels, mean estimate of gas is 2.39 trillion cubic feet, and mean estimate of natural gas liquids is 20.55 million barrels. For gas, 480.66 billion cubic feet (BCFG) is estimated for the Frontier-Muddy Continuous Gas AU, 115.34 BCFG for the Cody Sandstone Continuous Gas AU, 383.16 BCFG for the Mesaverde-Meeteetse Sandstone Continuous Gas AU, 711.30 BCFG for the Lance-Fort Union Sandstone Gas AU, 107.18 BCFG for the Mesaverde Coalbed Gas AU, 21.29 BCFG for the Meeteetse Coalbed Gas AU, and 118.08 BCFG for the Fort Union Coalbed Gas AU. All the undiscovered oil and 98.94 BCFG of undiscovered gas is in the Cretaceous-Tertiary Conventional Oil and Gas AU.
21 CFR 868.1400 - Carbon dioxide gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon dioxide gas analyzer. 868.1400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1400 Carbon dioxide gas analyzer. (a) Identification. A carbon dioxide gas analyzer is a device intended to measure the concentration of carbon dioxide...
21 CFR 868.1400 - Carbon dioxide gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon dioxide gas analyzer. 868.1400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1400 Carbon dioxide gas analyzer. (a) Identification. A carbon dioxide gas analyzer is a device intended to measure the concentration of carbon dioxide...
21 CFR 868.1700 - Nitrous oxide gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nitrous oxide gas analyzer. 868.1700 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1700 Nitrous oxide gas analyzer. (a) Identification. A nitrous oxide gas analyzer is a device intended to measure the concentration of nitrous oxide...
21 CFR 868.1400 - Carbon dioxide gas analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Carbon dioxide gas analyzer. 868.1400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1400 Carbon dioxide gas analyzer. (a) Identification. A carbon dioxide gas analyzer is a device intended to measure the concentration of carbon dioxide...
21 CFR 868.1400 - Carbon dioxide gas analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Carbon dioxide gas analyzer. 868.1400 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1400 Carbon dioxide gas analyzer. (a) Identification. A carbon dioxide gas analyzer is a device intended to measure the concentration of carbon dioxide...
21 CFR 868.1690 - Nitrogen gas analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nitrogen gas analyzer. 868.1690 Section 868.1690...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1690 Nitrogen gas analyzer. (a) Identification. A nitrogen gas analyzer is a device intended to measure the concentration of nitrogen in...
21 CFR 868.1690 - Nitrogen gas analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nitrogen gas analyzer. 868.1690 Section 868.1690...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1690 Nitrogen gas analyzer. (a) Identification. A nitrogen gas analyzer is a device intended to measure the concentration of nitrogen in...
21 CFR 868.1690 - Nitrogen gas analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nitrogen gas analyzer. 868.1690 Section 868.1690...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1690 Nitrogen gas analyzer. (a) Identification. A nitrogen gas analyzer is a device intended to measure the concentration of nitrogen in...
21 CFR 868.1720 - Oxygen gas analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1720 Oxygen gas analyzer. (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory...
21 CFR 868.1720 - Oxygen gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1720 Oxygen gas analyzer. (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory...
21 CFR 868.1720 - Oxygen gas analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1720 Oxygen gas analyzer. (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory...
21 CFR 868.1720 - Oxygen gas analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1720 Oxygen gas analyzer. (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory...
21 CFR 868.1720 - Oxygen gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1720 Oxygen gas analyzer. (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory...
40 CFR 1065.672 - Drift correction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... interval gas analyzer response to the span gas concentration. x postspan = post-test interval gas analyzer... = post-test interval gas analyzer response to the zero gas concentration. Example: x refzero = 0 µmol/mol... occurred before one or more previous test intervals. (4) For any post-test interval concentrations, use...
40 CFR 1065.672 - Drift correction.
Code of Federal Regulations, 2010 CFR
2010-07-01
... interval gas analyzer response to the span gas concentration. x postspan = post-test interval gas analyzer... = post-test interval gas analyzer response to the zero gas concentration. Example: x refzero = 0 µmol/mol... occurred before one or more previous test intervals. (4) For any post-test interval concentrations, use...
40 CFR 1065.672 - Drift correction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... interval gas analyzer response to the span gas concentration. x postspan = post-test interval gas analyzer... = post-test interval gas analyzer response to the zero gas concentration. Example: x refzero = 0 µmol/mol... occurred before one or more previous test intervals. (4) For any post-test interval concentrations, use...
40 CFR 1065.672 - Drift correction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... interval gas analyzer response to the span gas concentration. x postspan = post-test interval gas analyzer... = post-test interval gas analyzer response to the zero gas concentration. Example: x refzero = 0 µmol/mol... occurred before one or more previous test intervals. (4) For any post-test interval concentrations, use...
40 CFR 1065.672 - Drift correction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... interval gas analyzer response to the span gas concentration. x postspan = post-test interval gas analyzer... = post-test interval gas analyzer response to the zero gas concentration. Example: x refzero = 0 µmol/mol... occurred before one or more previous test intervals. (4) For any post-test interval concentrations, use...
NASA Astrophysics Data System (ADS)
Blackstock, J. M.; Covington, M. D.; Williams, S. G. W.; Myre, J. M.; Rodriguez, J.
2017-12-01
Variability in CO2 fluxes within Earth's Critical zone occurs over a wide range of timescales. Resolving this and its drivers requires high-temporal resolution monitoring of CO2 both in the soil and aquatic environments. High-cost (> 1,000 USD) gas analyzers and data loggers present cost-barriers for investigations with limited budgets, particularly if high spatial resolution is desired. To overcome high-costs, we developed an Arduino based CO2 measuring platform (i.e. gas analyzer and data logger). The platform was deployed at multiple sites within the Critical Zone overlying the Springfield Plateau aquifer in Northwest Arkansas, USA. The CO2 gas analyzer used in this study was a relatively low-cost SenseAir K30. The analyzer's optical housing was covered by a PTFE semi-permeable membrane allowing for gas exchange between the analyzer and environment. Total approximate cost of the monitoring platform was 200 USD (2% detection limit) to 300 USD (10% detection limit) depending on the K30 model used. For testing purposes, we deployed the Arduino based platform alongside a commercial monitoring platform. CO2 concentration time series were nearly identical. Notably, CO2 cycles at the surface water site, which operated from January to April 2017, displayed a systematic increase in daily CO2 amplitude. Preliminary interpretation suggests key observation of seasonally increasing stream metabolic function. Other interpretations of observed cyclical and event-based behavior are out of the scope of the study; however, the presented method describes an accurate near-hourly characterization of CO2 variability. The new platform has been shown to be operational for several months, and we infer reliable operation for much longer deployments (> 1 year) given adequate environmental protection and power supply. Considering cost-savings, this platform is an attractive option for continuous, accurate, low-power, and low-cost CO2 monitoring for remote locations, globally.
Klett, T.R.; Charpentier, Ronald R.
2003-01-01
The USGS FORSPAN model is designed for the assessment of continuous accumulations of crude oil, natural gas, and natural gas liquids (collectively called petroleum). Continuous (also called ?unconventional?) accumulations have large spatial dimensions and lack well defined down-dip petroleum/water contacts. Oil and natural gas therefore are not localized by buoyancy in water in these accumulations. Continuous accumulations include ?tight gas reservoirs,? coalbed gas, oil and gas in shale, oil and gas in chalk, and shallow biogenic gas. The FORSPAN model treats a continuous accumulation as a collection of petroleumcontaining cells for assessment purposes. Each cell is capable of producing oil or gas, but the cells may vary significantly from one another in their production (and thus economic) characteristics. The potential additions to reserves from continuous petroleum resources are calculated by statistically combining probability distributions of the estimated number of untested cells having the potential for additions to reserves with the estimated volume of oil and natural gas that each of the untested cells may potentially produce (total recovery). One such statistical method for combination of number of cells with total recovery, used by the USGS, is called ACCESS.
First Biogenic VOC Flux Results from the UCI Fluxtron Plant Chamber Facility
NASA Astrophysics Data System (ADS)
Seco, R.; Gu, D.; Joo, E.; Nagalingam, S.; Aristizabal, B. H.; Basu, C.; Kim, S.; Guenther, A. B.
2017-12-01
Atmospheric biogenic volatile organic compounds (BVOCs) have key environmental, ecological and biological roles, and can influence atmospheric chemistry, secondary aerosol formation, and regional climate. Quantifying BVOC emission rates and their impact on atmospheric chemistry is one of the greatest challenges with respect to predicting future air pollution in the context of a changing climate. A new facility, the UCI Fluxtron, has been developed at the Department of Earth System Science at the University of California Irvine to study the response of BVOC emissions to extreme weather and pollution stress. The UCI Fluxtron is designed for automated, continuous measurement of plant physiology and multi-modal BVOC chemical analysis from multiple plants. It consists of two controlled-environment walk-in growth chambers that contain several plant enclosures, a gas make-up system to precisely control the composition (e.g., H2O, CO2, O3 and VOC concentrations) of the air entering each enclosure. A sample manifold with automated inlet switching is used for measurements with in-situ and real-time VOC analysis instruments: H2O, CO2 fluxes can be measured continually with an infrared gas analyzer (IRGA) and BVOCs with a proton transfer reaction -time of flight- mass spectrometer (PTR-TOF-MS). Offline samples can also be taken via adsorbent cartridges to be analyzed in a thermal desorption gas chromatograph coupled to a TOF-MS detector. We present the first results of H2O, CO2 and BVOC fluxes, including the characterization and testing of the Fluxtron system. For example, measurements of young dragon tree (Paulownia elongata) individuals using whole-plant enclosures.
NASA Astrophysics Data System (ADS)
Li, Jinyi; Yang, Sen; Wang, Ruixue; Du, Zhenhui; Wei, Yingying
2017-10-01
Ammonia (NH3) is the most abundant alkalescency trace gas in the atmosphere having a foul odor, which is produced by both natural and anthropogenic sources. Chinese Emission Standard for Odor Pollutants has listed NH3 as one of the eight malodorous pollutants since 1993, specifying the emission concentration less than 1 mg/m3 (1.44ppmv). NH3 detection continuously from ppb to ppm levels is significant for protection of environmental atmosphere and safety of industrial and agricultural production. Tunable laser absorption spectroscopy (TLAS) is an increasingly important optical method for trace gas detection. TLAS do not require pretreatment and accumulation of the concentration of the analyzed sample, unlike, for example, more conventional methods such as mass spectrometry or gas chromatography. In addition, TLAS can provide high precision remote sensing capabilities, high sensitivities and fast response. Hollow waveguide (HWG) has recently emerged as a novel concept serving as an efficient optical waveguide and as a highly miniaturized gas cell. Among the main advantages of HWG gas cell compared with conventional multi-pass gas cells is the considerably decreased sample which facilitates gas exchanging. An ammonia sensor based on TLAS using a 5m HWG as the gas cell is report here. A 9.56μm, continuous-wave, distributed feed-back (DFB), room temperature quantum cascade laser (QCL), is employed as the optical source. The interference-free NH3 absorption line located at 1046.4cm-1 (λ 9556.6nm) is selected for detection by analyzing absorption spectrum from 1045-1047 cm-1 within the ν2 fundamental absorption band of ammonia. Direct absorption spectroscopy (DAS) technique is utilized and the measured spectral line is fitted by a simulation model by HITRAN database to obtain the NH3 concentration. The sensor performance is tested with standard gas and the result shows a 1σ minimum detectable concentration of ammonia is about 200 ppb with 1 sec time resolution. Benefitting from the use of QCL and HWG, the sensor is simple and compact. Moreover, the concentration inversion algorithm is simple and suitable for embedding into the microprocessor to form a more compact and miniaturized system. The absolute measurement based on DAS without calibration can reduce the influence of light variation on measurement which may attribute to the instability of electrocircuit, optical path and laser source. Therefore, the sensor based on HWG gas cell is very well suited for sensitive and real-time monitoring ammonia in the atmosphere. Furthermore, this sensor provides the capabilities for improved the in-situ gas-phase NH3 sensing relevant for emission source characterization and exhaled breath measurements.
NASA Astrophysics Data System (ADS)
Goodrich, J. P.; Zona, D.; Gioli, B.; Murphy, P.; Burba, G. G.; Oechel, W. C.
2015-12-01
Expanding eddy covariance measurements of CO2 and CH4 fluxes in the Arctic is critical for refining the global C budget. Continuous measurements are particularly challenging because of the remote locations, low power availability, and extreme weather conditions. The necessity for tailoring instrumentation at different sites further complicates the interpretation of results and may add uncertainty to estimates of annual CO2 budgets. We investigated the influence of different sensor combinations on FCO2, latent heat (LE), and FCH4, and assessed the differences in annual FCO2 estimated with different instrumentation at the same sites. Using data from four sites across the North Slope of Alaska, we resolved FCO2 and FCH4 to within 5% using different combinations of open- and closed-path gas analyzers and within 10% using heated and non-heated anemometers. A continuously heated anemometer increased data coverage relative to non-heated anemometers while resulting in comparable annual FCO2, despite over-estimating sensible heat fluxes by 15%. We also implemented an intermittent heating strategy whereby activation only when ice or snow blockage of the transducers was detected. This resulted in comparable data coverage (~ 60%) to the continuously heated anemometer, while avoiding potential over-estimation of sensible heat and gas fluxes. We found good agreement in FCO2 and FCH4 from two closed-path and one open-path gas analyzer, despite the need for large spectral corrections of closed-path fluxes and density and temperature corrections to open-path sensors. However, data coverage was generally greater when using closed-path, especially during cold seasons (36-40% vs 10-14% for the open path), when fluxes from Arctic regions are particularly uncertain and potentially critical to annual C budgets. Measurement of Arctic LE remains a challenge due to strong attenuation along sample tubes, even when heated, that could not be accounted for with spectral corrections.
The uniform quantized electron gas revisited
NASA Astrophysics Data System (ADS)
Lomba, Enrique; Høye, Johan S.
2017-11-01
In this article we continue and extend our recent work on the correlation energy of the quantized electron gas of uniform density at temperature T=0 . As before, we utilize the methods, properties, and results obtained by means of classical statistical mechanics. These were extended to quantized systems via the Feynman path integral formalism. The latter translates the quantum problem into a classical polymer problem in four dimensions. Again, the well known RPA (random phase approximation) is recovered as a basic result which we then modify and improve upon. Here we analyze the condition of thermodynamic self-consistency. Our numerical calculations exhibit a remarkable agreement with well known results of a standard parameterization of Monte Carlo correlation energies.
Highly efficient evaluation of a gas mixer using a hollow waveguide based laser spectral sensor
NASA Astrophysics Data System (ADS)
Du, Z.; Yang, X.; Li, J.; Yang, Y.; Qiao, C.
2017-05-01
This paper aims to provide a fast, sensitive, and accurate characterization of a Mass Flow Controller (MFC) based gas mixer. The gas mixer was evaluated by using a hollow waveguide based laser spectral sensor with high efficiency. Benefiting from the sensor's fast response, high sensitivity and continuous operation, multiple key parameters of the mixer, including mixing uncertainty, linearity, and response time, were acquired by a one-round test. The test results show that the mixer can blend multi-compound gases quite efficiently with an uncertainty of 1.44% occurring at a flow rate of 500 ml/min, with the linearity of 0.998 43 and the response time of 92.6 s. The results' reliability was confirmed by the relative measurement of gas concentration, in which the isolation of the sensor's uncertainty was conducted. The measured uncertainty has shown well coincidence with the theoretical uncertainties of the mixer, which proves the method to be a reliable characterization. Consequently, this sort of laser based characterization's wide appliance on gas analyzer's evaluations is demonstrated.
Highly efficient evaluation of a gas mixer using a hollow waveguide based laser spectral sensor.
Du, Z; Yang, X; Li, J; Yang, Y; Qiao, C
2017-05-01
This paper aims to provide a fast, sensitive, and accurate characterization of a Mass Flow Controller (MFC) based gas mixer. The gas mixer was evaluated by using a hollow waveguide based laser spectral sensor with high efficiency. Benefiting from the sensor's fast response, high sensitivity and continuous operation, multiple key parameters of the mixer, including mixing uncertainty, linearity, and response time, were acquired by a one-round test. The test results show that the mixer can blend multi-compound gases quite efficiently with an uncertainty of 1.44% occurring at a flow rate of 500 ml/min, with the linearity of 0.998 43 and the response time of 92.6 s. The results' reliability was confirmed by the relative measurement of gas concentration, in which the isolation of the sensor's uncertainty was conducted. The measured uncertainty has shown well coincidence with the theoretical uncertainties of the mixer, which proves the method to be a reliable characterization. Consequently, this sort of laser based characterization's wide appliance on gas analyzer's evaluations is demonstrated.
A Portable and Autonomous Mass Spectrometric System for On-Site Environmental Gas Analysis.
Brennwald, Matthias S; Schmidt, Mark; Oser, Julian; Kipfer, Rolf
2016-12-20
We developed a portable mass spectrometric system ("miniRuedi") for quantificaton of the partial pressures of He, Ne (in dry gas), Ar, Kr, N 2 , O 2 , CO 2 , and CH 4 in gaseous and aqueous matrices in environmental systems with an analytical uncertainty of 1-3%. The miniRuedi does not require any purification or other preparation of the sampled gases and therefore allows maintenance-free and autonomous operation. The apparatus is most suitable for on-site gas analysis during field work and at remote locations due to its small size (60 cm × 40 cm × 14 cm), low weight (13 kg), and low power consumption (50 W). The gases are continuously sampled and transferred through a capillary pressure reduction system into a vacuum chamber, where they are analyzed using a quadrupole mass spectrometer with a time resolution of ≲1 min. The low gas consumption rate (<0.1 mL/min) minimizes interference with the natural mass balance of gases in environmental systems, and allows the unbiased quantification of dissolved-gas concentrations in water by gas/water equilibration using membrane contractors (gas-equilibrium membrane-inlet mass spectrometry, GE-MIMS). The performance of the miniRuedi is demonstrated in laboratory and field tests, and its utility is illustrated in field applications related to soil-gas formation, lake/atmosphere gas exchange, and seafloor gas emanations.
21 CFR 868.1690 - Nitrogen gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... gas chromatography or mass spectrometry. (b) Classification. Class II (performance standards). ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nitrogen gas analyzer. 868.1690 Section 868.1690...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1690 Nitrogen gas analyzer. (a...
21 CFR 868.1690 - Nitrogen gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... gas chromatography or mass spectrometry. (b) Classification. Class II (performance standards). ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nitrogen gas analyzer. 868.1690 Section 868.1690...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1690 Nitrogen gas analyzer. (a...
Novel Apparatus for the Real-Time Quantification of Dissolved Gas Concentrations and Isotope Ratios
NASA Astrophysics Data System (ADS)
Gupta, M.; Leen, J.; Baer, D. S.; Owano, T. G.; Liem, J.
2013-12-01
Measurements of dissolved gases and their isotopic composition are critical in studying a variety of phenomena, including underwater greenhouse gas generation, air-surface exchange, and pollution migration. These studies typically involve obtaining water samples from streams, lakes, or ocean water and transporting them to a laboratory, where they are degased. The gases obtained are then generally measured using gas chromatography and isotope ratio mass spectrometry for concentrations and isotope ratios, respectively. This conventional, off-line methodology is time consuming, significantly limits the number of the samples that can be measured and thus severely inhibits detailed spatial and temporal mapping of gas concentrations and isotope ratios. In this work, we describe the development of a new membrane-based degassing device that interfaces directly to Los Gatos Research (cavity enhanced laser absorption or Off-Axis ICOS) gas analyzers (cavity enhanced laser absorption or Off-Axis ICOS analyzers) to create an autonomous system that can continuously and quickly measure concentrations and isotope ratios of dissolved gases in real time in the field. By accurately controlling the water flow rate through the membrane degasser, gas pressure on the outside of the membrane, and water pressure on the inside of the membrane, the system is able to generate precise and highly reproducible results. Moreover, by accurately measuring the gas flow rates in and out of the degasser, the gas-phase concentrations (ppm) could be converted into dissolved gas concentrations (nM). We will present detailed laboratory test data that quantifies the linearity, precision, and dynamic range of the system for the concentrations and isotope ratios of dissolved methane, carbon dioxide, and nitrous oxide. By interfacing the degassing device to a novel cavity-enhanced spectrometer (developed by LGR), preliminary data will also be presented for dissolved volatile organics (VOC) and other pollutants. Finally, the system was deployed shipboard, and field deployment data will also be presented.
A microfluidic device for open loop stripping of volatile organic compounds.
Cvetković, Benjamin Z; Dittrich, Petra S
2013-03-01
The detection of volatile organic compounds is of great importance for assessing the quality of water. In this contribution, we describe a miniaturized stripping device that allows fast online detection of organic solvents in water. The core component is a glass microfluidic chip that facilitates the creation of an annular-flowing stream of water and nitrogen gas. Volatile compounds are transferred efficiently from the water into the gas phase along the microfluidic pathway at room temperature within less than 5 s. Before exiting the microchip, the liquid phase is separated from the enriched gas phase by incorporating side capillaries through which the hydrophilic water phase is withdrawn. The gas phase is conveniently collected at the outlet reservoir by tubing. Finally, a semiconductor gas sensor analyzes the concentration of (volatile) organic compounds in the nitrogen gas. The operation and use of the stripping device is demonstrated for the organic solvents THF, 1-propanol, toluene, ethylbenzene, benzaldehyde, and methanol. The mobile, inexpensive, and continuously operating system with liquid flow rates in the low range of microliters per minute can be connected to other detectors or implemented in chemical production line for process control.
Linewidth and tuning characteristics of terahertz quantum cascade lasers.
Barkan, A; Tittel, F K; Mittleman, D M; Dengler, R; Siegel, P H; Scalari, G; Ajili, L; Faist, J; Beere, H E; Linfield, E H; Davies, A G; Ritchie, D A
2004-03-15
We have measured the spectral linewidths of three continuous-wave quantum cascade lasers operating at terahertz frequencies by heterodyning the free-running quantum cascade laser with two far-infrared gas lasers. Beat notes are detected with a GaAs diode mixer and a microwave spectrum analyzer, permitting very precise frequency measurements and giving instantaneous linewidths of less than -30 kHz. Characteristics are also reported for frequency tuning as the injection current is varied.
What controls deposition rate in electron-beam chemical vapor deposition?
White, William B; Rykaczewski, Konrad; Fedorov, Andrei G
2006-08-25
The key physical processes governing electron-beam-assisted chemical vapor deposition are analyzed via a combination of theoretical modeling and supporting experiments. The scaling laws that define growth of the nanoscale deposits are developed and verified using carefully designed experiments of carbon deposition from methane onto a silicon substrate. The results suggest that the chamber-scale continuous transport of the precursor gas is the rate controlling process in electron-beam chemical vapor deposition.
21 CFR 868.1430 - Carbon monoxide gas analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... techniques such as infrared absorption or gas chromatography. (b) Classification. Class II (performance... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a...
21 CFR 868.1430 - Carbon monoxide gas analyzer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... techniques such as infrared absorption or gas chromatography. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon monoxide gas analyzer. 868.1430 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1430 Carbon monoxide gas analyzer. (a...
Time-Resolved Rayleigh Scattering Measurements in Hot Gas Flows
NASA Technical Reports Server (NTRS)
Mielke, Amy F.; Elam, Kristie A.; Sung, Chih-Jen
2008-01-01
A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded gas flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultipler tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. Mean and rms velocity and temperature fluctuation measurements in both an electrically-heated jet facility with a 10-mm diameter nozzle and also in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA Glenn Research Center are presented.
NASA Astrophysics Data System (ADS)
Mei, Guohui; Zhang, Jiu; Zhao, Shumao; Xie, Zhi
2017-03-01
Fume exhaust system is the main component of the novel blackbody cavity sensor with a single layer tube, which removes the fume by gas flow along the exhaust pipe to keep the light path clean. However, the gas flow may break the conditions of blackbody cavity and results in the poor measurement accuracy. In this paper, we analyzed the influence of the gas flow on the temperature distribution of the measuring cavity, and then calculated the integrated effective emissivity of the non-isothermal cavity based on Monte-Carlo method, accordingly evaluated the sensor measurement accuracy, finally obtained the maximum allowable flow rate for various length of the exhaust pipe to meet the measurement accuracy. These results will help optimize the novel blackbody cavity sensor design and use it better for measuring the temperature of molten steel.
Dynamic contraction of the positive column of a self-sustained glow discharge in air flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shneider, M. N.; Mokrov, M. S.; Milikh, G. M.
We study the dynamic contraction of a self-sustained glow discharge in air in a rectangular duct with convective cooling. A two dimensional numerical model of the plasma contraction was developed in a cylindrical frame. The process is described by a set of time-dependent continuity equations for the electrons, positive and negative ions; gas and vibrational temperature; and equations which account for the convective heat and plasma losses by the transverse flux. Transition from the uniform to contracted state was analyzed. It was shown that such transition experiences a hysteresis, and that the critical current of the transition increases when themore » gas density drops. Possible coexistence of the contracted and uniform state of the plasma in the discharge, where the current flows along the density gradient of the background gas, is discussed.« less
40 CFR 86.135-90 - Dynamometer procedure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... petroleum gas-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO..., liquefied petroleum gas-fueled and methanol-fueled diesel-cycle vehicles), THC is sampled and analyzed... analyzed for THC, CO, CO2, CH4, and NOX. (3) For natural gas-fueled, liquefied petroleum gas-fueled and...
NASA Astrophysics Data System (ADS)
Melián, Gladys; Asensio-Ramos, María; Padrón, Eleazar; Barrancos, José; Hernández, Pedro A.; Pérez, Nemesio M.
2017-04-01
Tenerife is the largest island of the Canarian archipelago and several volcanic eruptions have occurred in the last 500 years, the last one in 1909. The main volcano-tectonic features of Tenerife Island are three main volcano-tectonic rifts trending N-E, N-W and N-S where, at the interception center is located Las Cañadas caldera and the stratovolcano Teide-Pico Viejo. Due to the approximately 1,500 wells and water galleries (1650 km) drilled during the last 150 years tapping the island's volcanic aquifer at different depths, Tenerife is a unique natural-scale laboratory for hydrological studies in oceanic volcanic islands. Ground waters are mainly Na+-HCO3- water type, mainly due to the continuous volcanic CO2 supply from the volcanic-hydrothermal system. A signi?cant number of these galleries show a CO2-rich inner atmosphere, and gas bubbling has also been detected inside some galleries. Since 2002, an automatic geochemical station installed at the entrance of the horizontal drilling "Fuente del Valle" (TFE02 station), Arona, Tenerife, measures the activities of 222Rn and 220Rn in the gas discharged from a CO2-rich gas bubbling spot located at 2.850 m depth. Interesting variations were recorded in the 222Rn/220Rn ratio after the period of 2004 anomalous seismicity and it has been demonstrated that this is a good control spot for volcanic surveillance (Pérez et al., 2007). Thus, in November 2016, a new type of laser based isotopic analyzer, a DeltaRayTM (Thermo Fisher Scientific) was installed in the TFE02 station to measure δ13C(CO2) directly in the gas discharged from the water. The gas, collected by means of an inverted funnel, is pumped (3 L min-1) towards the gallery entrance, where the instrumentation is located, through a polyamide pipe. During the study period the recorded data show a range of δ13C(CO2) from -6.2 to -4.2‰ vs. VPDB, with an average value of -5.1‰Ṫhese values are comparable to those ones measured in the gas sampled directly at the gas bubbling spot (˜-4.7‰ unpublished data) and analyzed with a Thermo Finnigan MAT 253 isotope ratio mass spectrometer, which supports the validity of the analytical method used. This is the first time that this type of instrumentation is used to continuously monitor the δ13C(CO2) isotopic composition of the gas discharged from a gas bubbling in a horizontal drill as a geochemical tool to evaluate the volcanic activity, in particular in Tenerife, a unique natural-scale laboratory for hydrological studies in oceanic volcanic islands. To correlate temporal variations in the δ13C(CO2) isotopic composition with changes in the seismic-volcanic activity of Tenerife, a longer observation period will be required. References: Pérez et al., 2007. Pure Appl. Geophys. DOI 10.1007/s00024-007-0280
NASA Astrophysics Data System (ADS)
Kalinowski, Paweł; Woźniak, Łukasz; Jasiński, Grzegorz; Jasiński, Piotr
2016-11-01
Gas analyzers based on gas sensors are the devices which enable recognition of various kinds of volatile compounds. They have continuously been developed and investigated for over three decades, however there are still limitations which slow down the implementation of those devices in many applications. For example, the main drawbacks are the lack of selectivity, sensitivity and long term stability of those devices caused by the drift of utilized sensors. This implies the necessity of investigations not only in the field of development of gas sensors construction, but also the development of measurement procedures or methods of analysis of sensor responses which compensate the limitations of sensors devices. One of the fields of investigations covers the dynamic measurements of sensors or sensor-arrays response with the utilization of flow modulation techniques. Different gas delivery patterns enable the possibility of extraction of unique features which improves the stability and selectivity of gas detecting systems. In this article three utilized flow modulation techniques are presented, together with the proposition of the evaluation method of their usefulness and robustness in environmental pollutants detecting systems. The results of dynamic measurements of an commercially available TGS sensor array in the presence of nitrogen dioxide and ammonia are shown.
A petroleum system model for gas hydrate deposits in northern Alaska
Lorenson, T.D.; Collett, Timothy S.; Wong, Florence L.
2011-01-01
Gas hydrate deposits are common on the North Slope of Alaska around Prudhoe Bay, however the extent of these deposits is unknown outside of this area. As part of a United States Geological Survey (USGS) and the Bureau of Land Management (BLM) gas hydrate research collaboration, well cutting and mud gas samples have been collected and analyzed from mainly industry-drilled wells on the Alaska North Slope for the purpose of prospecting for gas hydrate deposits. On the Alaska North Slope, gas hydrates are now recognized as an element within a petroleum systems approach or TPS (Total Petroleum System). Since 1979, 35 wells have been samples from as far west as Wainwright to Prudhoe Bay in the east. Geochemical studies of known gas hydrate occurrences on the North Slope have shown a link between gas hydrate and more deeply buried conventional oil and gas deposits. Hydrocarbon gases migrate from depth and charge the reservoir rock within the gas hydrate stability zone. It is likely gases migrated into conventional traps as free gas, and were later converted to gas hydrate in response to climate cooling concurrent with permafrost formation. Gas hydrate is known to occur in one of the sampled wells, likely present in 22 others based gas geochemistry and inferred by equivocal gas geochemistry in 11 wells, and absent in one well. Gas migration routes are common in the North Slope and include faults and widespread, continuous, shallowly dipping permeable sand sections that are potentially in communication with deeper oil and gas sources. The application of this model with the geochemical evidence suggests that gas hydrate deposits may be widespread across the North Slope of Alaska.
Characterization of fine particle and gaseous emissions during school bus idling.
Kinsey, J S; Williams, D C; Dong, Y; Logan, R
2007-07-15
The particulate matter (PM) and gaseous emissions from six diesel school buses were determined over a simulated waiting period typical of schools in the northeastern U.S. Testing was conducted for both continuous idle and hot restart conditions using a suite of on-line particle and gas analyzers installed in the U.S. Environmental Protection Agency's Diesel Emissions Aerosol Laboratory. The specific pollutants measured encompassed total PM-2.5 mass (PM < or = 2.5 microm in aerodynamic diameter), PM-2.5 number concentration, particle size distribution, particle-surface polycyclic aromatic hydrocarbons (PAHs), and a tracer gas (1,1,1,2,3,3,3-heptafluoropropane) in the diluted sample stream. Carbon monoxide (CO), carbon dioxide, nitrogen oxides (NO(x)), total hydrocarbons (THC), oxygen, formaldehyde, and the tracer gas were also measured in the raw exhaust. Results of the study showed little difference in the measured emissions between a 10 min post-restart idle and a 10 min continuous idle with the exception of THC and formaldehyde. However, an emissions pulse was observed during engine restart. A predictive equation was developed from the experimental data, which allows a comparison between continuous idle and hot restart for NO(x), CO, PM2.5, and PAHs and which considers factors such as the restart emissions pulse and periods when the engine is not running. This equation indicates that restart is the preferred operating scenario as long as there is no extended idling after the engine is restarted.
Laser Spectroscopy Multi-Gas Monitor: Results of Technology Demonstration on ISS
NASA Technical Reports Server (NTRS)
Mudgett, Paul D.; Pilgrim, Jeffrey S.
2015-01-01
Tunable diode laser spectroscopy (TDLS) is an up and coming trace and major gas monitoring technology with unmatched selectivity, range and stability. The technology demonstration of the 4 gas Multi-Gas Monitor (MGM), reported at the 2014 ICES conference, operated continuously on the International Space Station (ISS) for nearly a year. The MGM is designed to measure oxygen, carbon dioxide, ammonia and water vapor in ambient cabin air in a low power, relatively compact device. While on board, the MGM experienced a number of challenges, unplanned and planned, including a test of the ammonia channel using a commercial medical ammonia inhalant. Data from the unit was downlinked once per week and compared with other analytical resources on board, notably the Major Constituent Analyzer (MCA), a magnetic sector mass spectrometer. MGM spent the majority of the time installed in the Nanoracks Frame 2 payload facility in front breathing mode (sampling the ambient environment of the Japanese Experiment Module), but was also used to analyze recirculated rack air. The capability of the MGM to be operated in portable mode (via internal rechargeable lithium ion polymer batteries or by plugging into any Express Rack 28VDC connector) was a part of the usability demonstration. Results to date show unprecedented stability and accuracy of the MGM vs. the MCA for oxygen and carbon dioxide. The ammonia challenge (approx. 75 ppm) was successful as well, showing very rapid response time in both directions. Work on an expansion of capability in a next generation MGM has just begun. Combustion products and hydrazine are being added to the measurable target analytes. An 8 to 10 gas monitor (aka Gas Tricorder 1.0) is envisioned for use on ISS, Orion and Exploration missions.
Alternative Fuels Research Laboratory
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Nakley, Leah M.; Yen, Chia H.
2012-01-01
NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.
Argon Collection And Purification For Proliferation Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Achey, R.; Hunter, D.
2015-10-09
In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event wasmore » a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.« less
NASA Astrophysics Data System (ADS)
Rella, C. W.; Hoffnagle, J.; He, Y.; Tajima, S.
2015-10-01
In this paper, we present an innovative CH4, δ13CH4, and C2H6 instrument based on cavity ring-down spectroscopy (CRDS). The design and performance of the analyzer is presented in detail. The instrument is capable of precision of less than 1 ‰ on δ13CH4 with 1 in. of averaging and about 0.1 ‰ in an hour. Using this instrument, we present a comprehensive approach to atmospheric methane emissions attribution. Field measurements were performed in the Uintah Basin (Utah, USA) in the winter of 2013, using a mobile lab equipped with the CRDS analyzer, a high-accuracy GPS, a sonic anemometer, and an onboard gas storage and playback system. With a small population and almost no other sources of methane and ethane other than oil and gas extraction activities, the Uintah Basin represents an ideal location to investigate and validate new measurement methods of atmospheric methane and ethane. We present the results of measurements of the individual fugitive emissions from 23 natural gas wells and six oil wells in the region. The δ13CH4 and C2H6 signatures that we observe are consistent with the signatures of the gases found in the wells. Furthermore, regional measurements of the atmospheric CH4, δ13CH4, and C2H6 signatures throughout the basin have been made, using continuous sampling into a 450 m long tube and laboratory reanalysis with the CRDS instrument. These measurements suggest that 85 ± 7 % of the total emissions in the basin are from natural gas production.
Oil and gas reserves estimates
Harrell, R.; Gajdica, R.; Elliot, D.; Ahlbrandt, T.S.; Khurana, S.
2005-01-01
This article is a summary of a panel session at the 2005 Offshore Technology Conference. Oil and gas reserves estimates are further complicated with the expanding importance of the worldwide deepwater arena. These deepwater reserves can be analyzed, interpreted, and conveyed in a consistent, reliable way to investors and other stakeholders. Continually improving technologies can lead to improved estimates of production and reserves, but the estimates are not necessarily recognized by regulatory authorities as an indicator of "reasonable certainty," a term used since 1964 to describe proved reserves in several venues. Solutions are being debated in the industry to arrive at a reporting mechanism that generates consistency and at the same time leads to useful parameters in assessing a company's value without compromising confidentiality. Copyright 2005 Offshore Technology Conference.
Apparatus and method for monitoring of gas having stable isotopes
Clegg, Samuel M; Fessenden-Rahn, Julianna E
2013-03-05
Gas having stable isotopes is monitored continuously by using a system that sends a modulated laser beam to the gas and collects and transmits the light not absorbed by the gas to a detector. Gas from geological storage, or from the atmosphere can be monitored continuously without collecting samples and transporting them to a lab.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false 1A of Subpart W-Default Whole Gas Emission Factors for Onshore Petroleum and Natural Gas Production W Table W Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING...
Gas analysis system for the Eight Foot High Temperature Tunnel
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.; Davis, Patricia P.; Upchurch, Billy T.; Puster, Richard L.
1992-01-01
This paper describes the development of a gas collection and analysis system that is to be installed in the Eight-Foot High Temperature Tunnel (8' HTT) at NASA's Langley Research Center. This system will be used to analyze the test gas medium that results after burning a methane-air mixture to achieve the proper tunnel test parameters. The system consists of a sampling rake, a gas sample storage array, and a gas chromatographic system. Gas samples will be analyzed after each run to assure that proper combustion takes place in the tunnel resulting in a correctly balanced composition of the test gas medium. The proper ratio of gas species is critically necessary in order for the proper operation and testing of scramjet engines in the tunnel. After a variety of methane-air burn conditions have been analyzed, additional oxygen will be introduced into the combusted gas and the enriched test gas medium analyzed. The pre/post enrichment sets of data will be compared to verify that the gas species of the test gas medium is correctly balanced for testing of air-breathing engines.
Chien, T W; Chu, H; Hsu, W C; Tseng, T K; Hsu, C H; Chen, K Y
2003-08-01
The continuous emission monitoring system (CEMS) can monitor flue gas emissions continuously and instantaneously. However, it has the disadvantages of enormous cost, easily producing errors in sampling periods of bad weather, lagging response in variable ambient environments, and missing data in daily zero and span tests and maintenance. The concept of a predictive emission monitoring system (PEMS) is to use the operating parameters of combustion equipment through thermodynamic or statistical methods to construct a mathematic model that can predict emissions by a computer program. The goal of this study is to set up a PEMS in a gas-fired combined cycle power generation unit at the Hsinta station of Taiwan Power Co. The emissions to be monitored include nitrogen oxides (NOx) and oxygen (O2) in flue gas. The major variables of the predictive model were determined based on the combustion theory. The data of these variables then were analyzed to establish a regression model. From the regression results, the influences of these variables are discussed and the predicted values are compared with the CEMS data for accuracy. In addition, according to the cost information, the capital and operation and maintenance costs for a PEMS can be much lower than those for a CEMS.
33 CFR 127.201 - Sensing and alarm systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm...
33 CFR 127.201 - Sensing and alarm systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm...
Gas in the Uinta Basin, Utah - Resources in continuous accumulations
Schmoker, J.W.; Fouch, T.D.; Charpentier, R.R.
1996-01-01
Continuous-type gas plays can be envisioned as large areas within which the reservoir rock is everywhere charged with gas. As part of its 1995 National Assessment of oil and gas resources, the U.S. Geological Survey identified four continuous-type gas plays in the Uinta Basin. These occur in sandstone reservoirs of the lower Tertiary Wasatch Formation (two plays) and the underlying Upper Cretaceous Mesaverde Group (two plays). Only the play representing the eastern part of the Wasatch Formation continuous accumulation (Natural Buttes area) has been the target of appreciable drilling activity to date. The volume of undiscovered gas estimated to be recoverable from these four plays using existing technology and development practices ranges between 3.7 trillion cubic feet of gas (TCFG) (95th fractile) and 11.9 TCFG (5th fractile), and averages 7.0 TCFG. However, these are geologically based resource estimates, made without direct reference to economic viability. Economic analysis indicates that only a fraction of this assessed resource could be economically found and produced at prices less than $2.00 per thousand cubic feet of gas (MCFG), based on costs that prevailed at the beginning of 1993. Production characteristics of continuous-type gas plays vary significantly from well to well. Difficulty in identifying locations with poor production characteristics in advance of drilling contributes to the unfavorable economics of some plays. The need exists for improvements in technology and geologic understanding that increase the chances of selectively drilling the more productive locations within a continuous-type play.
A temperature-controlled photoelectrochemical cell for quantitative product analysis.
Corson, Elizabeth R; Creel, Erin B; Kim, Youngsang; Urban, Jeffrey J; Kostecki, Robert; McCloskey, Bryan D
2018-05-01
In this study, we describe the design and operation of a temperature-controlled photoelectrochemical cell for analysis of gaseous and liquid products formed at an illuminated working electrode. This cell is specifically designed to quantitatively analyze photoelectrochemical processes that yield multiple gas and liquid products at low current densities and exhibit limiting reactant concentrations that prevent these processes from being studied in traditional single chamber electrolytic cells. The geometry of the cell presented in this paper enables front-illumination of the photoelectrode and maximizes the electrode surface area to electrolyte volume ratio to increase liquid product concentration and hence enhances ex situ spectroscopic sensitivity toward them. Gas is bubbled through the electrolyte in the working electrode chamber during operation to maintain a saturated reactant concentration and to continuously mix the electrolyte. Gaseous products are detected by an in-line gas chromatograph, and liquid products are analyzed ex situ by nuclear magnetic resonance. Cell performance was validated by examining carbon dioxide reduction on a silver foil electrode, showing comparable results both to those reported in the literature and identical experiments performed in a standard parallel-electrode electrochemical cell. To demonstrate a photoelectrochemical application of the cell, CO 2 reduction experiments were carried out on a plasmonic nanostructured silver photocathode and showed different product distributions under dark and illuminated conditions.
Atmospheric Carbon Dioxide Record from In Situ Measurements at Mt. Cimone (1979-1997)
Colombo, Tiziano [Italian Meteorological Service, Sestola (MO), Italy; Santaguida, Riccardo
1998-01-01
Continuous atmospheric CO2 measurements have been carried out at Mt. Cimone since 1979. Since December 1988, air samples have also been collected approximately once per week in a pair of 2-L, electropolished, stainless steel cylindrical flasks. From 1979 until December 1988, a Hartmann and Braun URAS-2T NDIR gas analyzer was used for CO2 determinations. Currently, CO2 determinations are made through the use of a Siemens Ultramat-5E NDIR gas analyzer. Water vapor is eliminated by passing the air through a U-tube placed in an alcohol bath at -600°C. Calibration of the Ultramat-5E is accomplished by using two CO2-in-air working standard gases. These working standard gas concentrations are checked 10 days apart against three CO2-in-air mixtures that serve as secondary standards. The secondary standards are checked every 6 months against five other CO2-in-air primary standards. Hourly CO2 values are routinely plotted together with wind data. Anomalous concentrations and those affected by instrument failures or local sources are rejected. Atmospheric CO2 concentrations from Mt. Cimone are reported in the 1993 WMO/Scripps mole fraction scale. For further details on the measurement apparatus and sampling techniques used at Mt. Cimone, see Cundari et al. (1990).
A temperature-controlled photoelectrochemical cell for quantitative product analysis
NASA Astrophysics Data System (ADS)
Corson, Elizabeth R.; Creel, Erin B.; Kim, Youngsang; Urban, Jeffrey J.; Kostecki, Robert; McCloskey, Bryan D.
2018-05-01
In this study, we describe the design and operation of a temperature-controlled photoelectrochemical cell for analysis of gaseous and liquid products formed at an illuminated working electrode. This cell is specifically designed to quantitatively analyze photoelectrochemical processes that yield multiple gas and liquid products at low current densities and exhibit limiting reactant concentrations that prevent these processes from being studied in traditional single chamber electrolytic cells. The geometry of the cell presented in this paper enables front-illumination of the photoelectrode and maximizes the electrode surface area to electrolyte volume ratio to increase liquid product concentration and hence enhances ex situ spectroscopic sensitivity toward them. Gas is bubbled through the electrolyte in the working electrode chamber during operation to maintain a saturated reactant concentration and to continuously mix the electrolyte. Gaseous products are detected by an in-line gas chromatograph, and liquid products are analyzed ex situ by nuclear magnetic resonance. Cell performance was validated by examining carbon dioxide reduction on a silver foil electrode, showing comparable results both to those reported in the literature and identical experiments performed in a standard parallel-electrode electrochemical cell. To demonstrate a photoelectrochemical application of the cell, CO2 reduction experiments were carried out on a plasmonic nanostructured silver photocathode and showed different product distributions under dark and illuminated conditions.
40 CFR 89.416 - Raw exhaust gas flow.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Raw exhaust gas flow. 89.416 Section 89.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Procedures § 89.416 Raw exhaust gas flow. The exhaust gas flow shall be determined by one of the methods...
40 CFR 89.416 - Raw exhaust gas flow.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Raw exhaust gas flow. 89.416 Section 89.416 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Procedures § 89.416 Raw exhaust gas flow. The exhaust gas flow shall be determined by one of the methods...
Acikgoz, Seyyid Bilal; Genc, Ahmet Bilal; Sipahi, Savas; Yildirim, Mehmet; Cinemre, Behice; Tamer, Ali; Solak, Yalcin
2016-05-01
Several studies investigated the agreement between central laboratory biochemistry analyzers and blood gas analyzers for potassium measurements. However, data are scarce when the potassium level is moderate to severely high. We aimed to evaluate the agreement between central laboratory biochemistry analyzers and blood gas analyzer in terms of serum potassium level measurement because differences in potassium at this level translate into very different clinical actions. This was a retrospective medical record review study in which patients who presented to the emergency department and had serum potassium levels ≥6mmol/L were included. Patients who did not have simultaneous potassium measurement by blood gas analyzer were excluded. We included all patients meeting potassium criteria irrespective of their underlying disease or comorbidities. We evaluated agreement between the measurement methods with Pearson correlation, Bland-Altman plot, and Sign test. A total of 118 blood sample pairs were included. The mean serum potassium level measured by biochemistry analyzer was 6.78±0.79mmol/L, whereas it was 6.16±0.86mmol/L by blood gas analyzer (P<.001, Sign test). There was a strong correlation (P<.001, r=0.864) between the 2 methods, but agreement was relatively poor. Blood gas analyzer tended to measure potassium significantly lower than measured by biochemistry analyzer. The mean difference between the methods was 0.62±0.43mmol/L. In patients with moderate to severe hyperkalemia, blood gas analyzer and biochemistry analyzer gives significantly different serum potassium results which may be clinically important. Copyright © 2016 Elsevier Inc. All rights reserved.
Ryder, Robert T.; Aggen, Kerry L.; Hettinger, Robert D.; Law, Ben E.; Miller, John J.; Nuccio, Vito F.; Perry, William J.; Prensky, Stephen E.; Filipo, John J.; Wandrey, Craig J.
1996-01-01
INTRODUCTION: In the U.S. Geological Survey's (USGS) 1995 National Assessment of United States oil and gas resources (Gautier and others, 1995), the Appalachian basin was estimated to have, at a mean value, about 61 trillion cubic feet (TCF) of recoverable gas in sandstone and shale reservoirs of Paleozoic age. Approximately one-half of this gas resource is estimated to reside in a regionally extensive, continuous-type gas accumulation whose reservoirs consist of low-permeability sandstone of the Lower Silurian 'Clinton' sands and Medina Group (Gautier and others, 1995; Ryder, 1995). Recognizing the importance of this large regional gas accumulation for future energy considerations, the USGS initiated in January 1995 a multi-year study to evaluate the nature, distribution, and origin of natural gas in the 'Clinton' sands, Medina Group sandstones, and equivalent Tuscarora Sandstone. The project is part of a larger natural gas project, Continuous Gas Accumulations in Sandstones and Carbonates, coordinated in FY1995 by Ben E. Law and Jennie L. Ridgley, USGS, Denver. Approximately 2.6 man years were devoted to the Clinton/Medina project in FY1995. A continuous-type gas accumulation, referred to in the project, is a new term introduced by Schmoker (1995a) to identify those natural gas accumulations whose reservoirs are charged throughout with gas over a large area and whose entrapment does not involve a downdip gas-water contact. Gas in these accumulations is located downdip of the water column and, thus, is the reverse of conventional-type hydrocarbon accumulations. Commonly used industry terms that are more or less synonymous with continuous-type gas accumulations include basin- centered gas accumulation (Rose and others, 1984; Law and Spencer, 1993), tight (low-permeability) gas reservoir (Spencer, 1989; Law and others, 1989; Perry, 1994), and deep basin gas (Masters, 1979, 1984). The realization that undiscovered gas in Lower Silurian sandstone reservoirs of the Appalachian basin probably occurs in a continuous accumulation rather than in conventionally trapped, discrete accumulations represents a significant departure from the 1989 National Assessment (Mast and others, 1989; deWitt, 1993). In 1989, a direct assessment (field-size distributions required for play analysis were unavailable) of the Lower Silurian sandstone play gave, at a mean value, about 1.7 TCF of gas. The 1995 estimate (~30 TCF of gas) is so much greater than the 1989 estimate (~1.7 TCF of gas) because of the interpreted continuous nature of the accumulation and the assessment methodology applied. The methodology for continuous hydrocarbon accumulations assumes that the reservoirs in the accumulation are gas-saturated and takes into account: 1) estimated ultimate recovery (EUR) per well probability distributions, 2) optimum area that a well can drain (spacing), 3) number of untested drill sites having the appropriate spacing area, 4) success ratio of previously drilled holes, and 5) risk (Schmoker, 1995b). Davis (1984), Zagorski (1988, 1991), and Law and Spencer (1993) were among the first petroleum geologists to suggest that gas in the 'Clinton' sands and Medina Group sandstones was trapped in a basin-centered/deep basin accumulation. They recognized many of the earmarks of a basin-centered/deep basin accumulation such as low-permeability reservoirs, abnormally low formation pressure, coalesced gas fields, gas shows or production in most holes drilled, low water yields, and a general lack of structural control on entrapment. Ryder (1995) adopted this interpretation by defining four continuous-type gas plays (6728-6731) in the 'Clinton' sands-Medina Group interval (fig.1). Play 6728 (Clinton/Medina sandstone gas high potential) covers a 17,000 sq mi region of western New York, northwestern Pennsylvania, eastern Ohio, and a small part of westernmost West Virginia that is very favorable for future gas resources (fig.1). Also, this play includes a l
26 CFR 1.263A-13 - Oil and gas activities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 3 2011-04-01 2011-04-01 false Oil and gas activities. 1.263A-13 Section 1.263A... (CONTINUED) INCOME TAXES (CONTINUED) Items Not Deductible § 1.263A-13 Oil and gas activities. (a) In general... section 263A(g)) of oil or gas property. For this purpose, oil or gas property consists of each separate...
26 CFR 1.263A-13 - Oil and gas activities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 3 2014-04-01 2014-04-01 false Oil and gas activities. 1.263A-13 Section 1.263A... (CONTINUED) INCOME TAXES (CONTINUED) Items Not Deductible § 1.263A-13 Oil and gas activities. (a) In general... section 263A(g)) of oil or gas property. For this purpose, oil or gas property consists of each separate...
26 CFR 1.263A-13 - Oil and gas activities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 3 2012-04-01 2012-04-01 false Oil and gas activities. 1.263A-13 Section 1.263A... (CONTINUED) INCOME TAXES (CONTINUED) Items Not Deductible § 1.263A-13 Oil and gas activities. (a) In general... section 263A(g)) of oil or gas property. For this purpose, oil or gas property consists of each separate...
26 CFR 1.263A-13 - Oil and gas activities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 3 2013-04-01 2013-04-01 false Oil and gas activities. 1.263A-13 Section 1.263A... (CONTINUED) INCOME TAXES (CONTINUED) Items Not Deductible § 1.263A-13 Oil and gas activities. (a) In general... section 263A(g)) of oil or gas property. For this purpose, oil or gas property consists of each separate...
On the physics-based processes behind production-induced seismicity in natural gas fields
NASA Astrophysics Data System (ADS)
Zbinden, Dominik; Rinaldi, Antonio Pio; Urpi, Luca; Wiemer, Stefan
2017-04-01
Induced seismicity due to natural gas production is observed at different sites around the world. Common understanding is that the pressure drop caused by gas production leads to compaction, which affects the stress field in the reservoir and the surrounding rock formations, hence reactivating pre-existing faults and inducing earthquakes. Previous studies have often assumed that pressure changes in the reservoir compartments and intersecting fault zones are equal, while neglecting multi-phase fluid flow. In this study, we show that disregarding fluid flow involved in natural gas extraction activities is often inappropriate. We use a fully coupled multiphase fluid flow and geomechanics simulator, which accounts for stress-dependent permeability and linear poroelasticity, to better determine the conditions leading to fault reactivation. In our model setup, gas is produced from a porous reservoir, cut in two compartments that are offset by a normal fault, and overlain by impermeable caprock. Results show that fluid flow plays a major role pertaining to pore pressure and stress evolution within the fault. Hydro-mechanical processes include rotation of the principal stresses due to reservoir compaction, as well as poroelastic effects caused by the pressure drop in the adjacent reservoir. Fault strength is significantly reduced due to fluid flow into the fault zone from the neighbouring reservoir compartment and other formations. We also analyze the case of production in both compartments, and results show that simultaneous production does not prevent the fault to be reactivated, but the magnitude of the induced event is smaller. Finally, we analyze scenarios for minimizing seismicity after a period of production, such as (i) well shut-in and (ii) gas re-injection. Results show that, in the case of well shut-in, a highly stressed fault zone can still be reactivated several decades after production stop, although in average the shut-in results in reduction of seismicity. In the case of gas re-injection, fault reactivation can be avoided if gas is injected directly into the compartment under depletion. However, accounting for continuous production at a given reservoir and gas re-injection at a neighbouring compartment does not stop the fault from being reactivated.
NASA Technical Reports Server (NTRS)
Ravindram, M.; Kallvinskas, J. J. (Inventor)
1985-01-01
High sulfur content carbonaceous material, such as coal is desulfurized by continuous fluidized suspension in a reactor with chlorine gas, inert dechlorinating gas and hydrogen gas. A source of chlorine gas, a source of inert gas and a source of hydrogen gas are connected to the bottom inlet through a manifold and a heater. A flow controler operates servos in a manner to continuously and sequentially suspend coal in the three gases. The sulfur content is reduced at least 50% by the treatment.
NASA Astrophysics Data System (ADS)
Baudic, Alexia; Gros, Valérie; Bonsang, Bernard; Baisnee, Dominique; Vogel, Félix; Yver Kwok, Camille; Ars, Sébastien; Finlayson, Andrew; Innocenti, Fabrizio; Robinson, Rod
2015-04-01
Since the 1970's, the natural gas consumption saw a rapid growth in large urban centers, thus becoming an important energy resource to meet continuous needs of factories and inhabitants. Nevertheless, it can be a substantial source of methane (CH4) and pollutants in urban areas. For instance, we have determined that about 20% of Volatile Organic Compounds (VOCs) in downtown Paris are originating from this emission source (Baudic, Gros et al., in preparation). Within the framework of the "Fugitive Methane Emissions" (FuME) project (Climate-KIC, EIT); 2-weeks gas measurements were conducted at a gas compressor station in Northern Europe. Continuous ambient air measurements of methane and VOCs concentrations were performed using a cavity ring-down spectrometer (model G2201, Picarro Inc., Santa Clara, USA) and two portable GC-FID (Chromatotec, Saint-Antoine, France), respectively. On-site near-field samplings were also carried out at the source of two pipelines using stainless steel flasks (later analyzed with a laboratory GC-FID). The objective of this study aims to use VOCs as additional tracers in order to better characterize the fugitive methane emissions in a complex environment, which can be affected by several urban sources (road-traffic, others industries, etc.). Moreover, these measurements have allowed determining the chemical composition of this specific source. Our results revealed that the variability of methane and some VOCs was (rather) well correlated, especially for alkanes (ethane, propane, etc.). An analysis of selected events with strong concentrations enhancement was performed using ambient air measurements; thus allowing the preliminary identification of different emission sources. In addition, some flasks were also sampled in Paris to determine the local natural gas composition. A comparison between both was then performed. Preliminary results from these experiments will be presented here.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauvaux, Thomas
Natural Gas (NG) production activities in the northeastern Marcellus shale have significantly increased in the last decade, possibly releasing large amounts of methane (CH 4) into the atmosphere from the operations at the productions sites and during the processing and transmission steps of the natural gas chain. Based on an intensive aircraft survey, leakage rates from the NG production were quantified in May 2015 and found to be in the order of 0.5% of the total production, higher than reported by the Environmental Protection Agency (EPA) but below the usually observed leakage rates over the shale gases in the US.more » Thanks to the high production rates on average at each well, leakage rates normalized by production appeared to be low in the northeastern Marcellus shale. This result confirms that natural gas production using unconventional techniques in this region is emitting relatively less CH 4 into the atmosphere than other shale reservoirs. The low emissions rate can be explained in part by the high productivity of wells drilled across the northeastern Marcellus region. We demonstrated here that atmospheric monitoring techniques can provide an independent quantification of NG leakage rates using aircraft measurements. The CH 4 analyzers were successfully calibrated at four sites across the region, measuring continuously the atmospheric CH 4 mixing ratios and isotopic 13Ch 4. Our preliminary findings confirm the low leakage rates from tower data collected over September 2015 to November 2016 compared to the aircraft mass-balance estimates in may 2015. However, several episodes revealing large releases of natural gas over several weeks showed that temporal variations in the emissions of CH 4 may increase the actual leakage rate over longer time periods.« less
Geochemistry of a naturally occurring massive marine gas hydrate
Kvenvolden, K.A.; Claypool, G.E.; Threlkeld, C.N.; Dendy, Sloan E.
1984-01-01
During Deep Sea Drilling Project (DSDP) Leg 84 a core 1 m long and 6 cm in diameter of massive gas hydrate was unexpectedly recovered at Site 570 in upper slope sediment of the Middle America Trench offshore of Guatemala. This core contained only 5-7% sediment, the remainder being the solid hydrate composed of gas and water. Samples of the gas hydrate were decomposed under controlled conditions in a closed container maintained at 4??C. Gas pressure increased and asymptotically approached the equilibrium decomposition pressure for an ideal methane hydrate, CH4.5-3/4H2O, of 3930 kPa and approached to this pressure after each time gas was released, until the gas hydrate was completely decomposed. The gas evolved during hydrate decomposition was 99.4% methane, ???0.2% ethane, and ???0.4% CO2. Hydrocarbons from propane to heptane were also present, but in concentrations of less than 100 p.p.m. The carbon-isotopic composition of methane was -41 to -44 permil(( 0 00), relative to PDB standard. The observed volumetric methane/water ratio was 64 or 67, which indicates that before it was stored and analyzed, the gas hydrate probably had lost methane. The sample material used in the experiments was likely a mixture of methane hydrate and water ice. Formation of this massive gas hydrate probably involved the following processes: (i) upward migration of gas and its accumulation in a zone where conditions favored the growth of gas hydrates, (ii) continued, unusually rapid biological generation of methane, and (iii) release of gas from water solution as pressure decreased due to sea level lowering and tectonic uplift. ?? 1984.
40 CFR 86.521-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Analyzers used with petroleum fuels and liquefied petroleum gas-fuel shall be optimized using propane. Analyzers used with natural gas-fuel for measurement of hydrocarbons shall be optimized using methane. If a... gas-fuel. Alternate methods yielding equivalent results may be used, if approved in advance by the...
40 CFR 86.521-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Analyzers used with petroleum fuels and liquefied petroleum gas-fuel shall be optimized using propane. Analyzers used with natural gas-fuel for measurement of hydrocarbons shall be optimized using methane. If a... gas-fuel. Alternate methods yielding equivalent results may be used, if approved in advance by the...
40 CFR 86.1221-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... methane. When the FID analyzer to be used for the analysis of natural gas-fueled vehicle hydrocarbon... and liquefied petroleum gas-fuel shall be optimized using propane. Analyzers used with natural gas... air (or methane in air as appropriate) calibration gases having nominal concentrations of 15, 30, 45...
40 CFR 86.521-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Analyzers used with petroleum fuels and liquefied petroleum gas-fuel shall be optimized using propane. Analyzers used with natural gas-fuel for measurement of hydrocarbons shall be optimized using methane. If a... gas-fuel. Alternate methods yielding equivalent results may be used, if approved in advance by the...
40 CFR 86.1221-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... methane. When the FID analyzer to be used for the analysis of natural gas-fueled vehicle hydrocarbon... and liquefied petroleum gas-fuel shall be optimized using propane. Analyzers used with natural gas... air (or methane in air as appropriate) calibration gases having nominal concentrations of 15, 30, 45...
NASA Astrophysics Data System (ADS)
Karacan, C. Özgen; Olea, Ricardo A.
2014-06-01
Prediction of potential methane emission pathways from various sources into active mine workings or sealed gobs from longwall overburden is important for controlling methane and for improving mining safety. The aim of this paper is to infer strata separation intervals and thus gas emission pathways from standard well log data. The proposed technique was applied to well logs acquired through the Mary Lee/Blue Creek coal seam of the Upper Pottsville Formation in the Black Warrior Basin, Alabama, using well logs from a series of boreholes aligned along a nearly linear profile. For this purpose, continuous wavelet transform (CWT) of digitized gamma well logs was performed by using Mexican hat and Morlet, as the mother wavelets, to identify potential discontinuities in the signal. Pointwise Hölder exponents (PHE) of gamma logs were also computed using the generalized quadratic variations (GQV) method to identify the location and strength of singularities of well log signals as a complementary analysis. PHEs and wavelet coefficients were analyzed to find the locations of singularities along the logs. Using the well logs in this study, locations of predicted singularities were used as indicators in single normal equation simulation (SNESIM) to generate equi-probable realizations of potential strata separation intervals. Horizontal and vertical variograms of realizations were then analyzed and compared with those of indicator data and training image (TI) data using the Kruskal-Wallis test. A sum of squared differences was employed to select the most probable realization representing the locations of potential strata separations and methane flow paths. Results indicated that singularities located in well log signals reliably correlated with strata transitions or discontinuities within the strata. Geostatistical simulation of these discontinuities provided information about the location and extents of the continuous channels that may form during mining. If there is a gas source within their zone of influence, paths may develop and allow methane movement towards sealed or active gobs under pressure differentials. Knowledge gained from this research will better prepare mine operations for potential methane inflows, thus improving mine safety.
Gentle Heating by Mixing in Cooling Flow Clusters
NASA Astrophysics Data System (ADS)
Hillel, Shlomi; Soker, Noam
2017-08-01
We analyze 3D hydrodynamical simulations of the interaction of jets and the bubbles they inflate with the intracluster medium (ICM) and show that the heating of the ICM by mixing hot bubble gas with the ICM operates over tens of millions of years and hence can smooth the sporadic activity of the jets. The inflation process of hot bubbles by propagating jets forms many vortices, and these vortices mix the hot bubble gas with the ICM. The mixing, and hence the heating of the ICM, starts immediately after the jets are launched, but continues for tens of millions of years. We suggest that the smoothing of the active galactic nucleus (AGN) sporadic activity by the long-lived vortices accounts for the recent finding of a gentle energy coupling between AGN heating and the ICM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-12-01
The feasibility of utilizing geothermal energy at a selected plant in New York State was studied. Existing oil and gas records suggests that geothermal fluid is available in the target area and based on this potential. Friendship Dairies, Inc., Friendship, NY, was selected as a potential user of geothermal energy. Currently natural gas and electricity are used as its primary energy sources. Six geothermal system configurations were analyzed based on replacement of gas or oil-fired systems for producing process heat. Each system was evaluated in terms of Internal Rate of Return on Investment (IRR), and simple payback. Six system configurationsmore » and two replaced fuels, representative of a range of situations found in the state, are analyzed. Based on the potential geothermal reserves at Friendship, each of the six system configurations are shown to be economically viable, compared to continued gas or oil-firing. The Computed IRR's are all far in excess of projected average interest rates for long term borrowings: approximately 15% for guarantee backed loans or as high as 20% for conventional financing. IRR is computed based on the total investment (equity plus debt) and cash flows before financing costs, i.e., before interest expense, but after the tax benefit of the interest deduction. The base case application for the Friendship analysis is case B/20 yr-gas which produces an IRR of 28.5% and payback of 3.4 years. Even better returns could be realized in the cases of oil-avoidance and where greater use of geothermal energy can be made as shown in the other cases considered.« less
Monitoring fluidized bed drying of pharmaceutical granules.
Briens, Lauren; Bojarra, Megan
2010-12-01
Placebo granules consisting of lactose monohydrate, corn starch, and polyvinylpyrrolidone were prepared using de-ionized water in a high-shear mixer and dried in a conical fluidized bed dryer at various superficial gas velocities. Acoustic, vibration, and pressure data obtained over the course of drying was analyzed using various statistical, frequency, fractal, and chaos techniques. Traditional monitoring methods were also used for reference. Analysis of the vibration data showed that the acceleration levels decreased during drying and reached a plateau once the granules had reached a final moisture content of 1–2 wt.%; this plateau did not differ significantly between superficial gas velocities, indicating a potential criterion to support drying endpoint identification. Acoustic emissions could not reliably identify the drying endpoint. However, high kurtosis values of acoustic emissions measured in the filtered air exhaust corresponded to high entrainment rates. This could be used for process control to adjust the fluidization gas velocity to allow drying to continue rapidly while minimizing entrainment and possible product losses.
Modern air protection technologies at thermal power plants (review)
NASA Astrophysics Data System (ADS)
Roslyakov, P. V.
2016-07-01
Realization of the ecologically safe technologies for fuel combustion in the steam boiler furnaces and the effective ways for treatment of flue gases at modern thermal power plants have been analyzed. The administrative and legal measures to stimulate introduction of the technologies for air protection at TPPs have been considered. It has been shown that both the primary intrafurnace measures for nitrogen oxide suppression and the secondary flue gas treatment methods are needed to meet the modern ecological standards. Examples of the environmentally safe methods for flame combustion of gas-oil and solid fuels in the boiler furnaces have been provided. The effective methods and units to treat flue gases from nitrogen and sulfur oxides and flue ash have been considered. It has been demonstrated that realization of the measures for air protection should be accompanied by introduction of the systems for continuous instrumentation control of the composition of combustion products in the gas path of boiler units and for monitoring of atmospheric emissions.
NASA Astrophysics Data System (ADS)
Qu, Junbo; Yan, Tie; Sun, Xiaofeng; Chen, Ye; Pan, Yi
2017-10-01
With the development of drilling technology to deeper stratum, overflowing especially gas cut occurs frequently, and then flow regime in wellbore annulus is from the original drilling fluid single-phase flow into gas & liquid two-phase flow. By using averaged two-fluid model equations and the basic principle of fluid mechanics to establish the continuity equations and momentum conservation equations of gas phase & liquid phase respectively. Relationship between pressure and density of gas & liquid was introduced to obtain hyperbolic equation, and get the expression of the dimensionless eigenvalue of the equation by using the characteristic line method, and analyze wellbore flow regime to get the critical gas content under different virtual mass force coefficients. Results show that the range of equation eigenvalues is getting smaller and smaller with the increase of gas content. When gas content reaches the critical point, the dimensionless eigenvalue of equation has no real solution, and the wellbore flow regime changed from bubble flow to bomb flow. When virtual mass force coefficients are 0.50, 0.60, 0.70 and 0.80 respectively, the critical gas contents are 0.32, 0.34, 0.37 and 0.39 respectively. The higher the coefficient of virtual mass force, the higher gas content in wellbore corresponding to the critical point of transition flow regime, which is in good agreement with previous experimental results. Therefore, it is possible to determine whether there is a real solution of the dimensionless eigenvalue of equation by virtual mass force coefficient and wellbore gas content, from which we can obtain the critical condition of wellbore flow regime transformation. It can provide theoretical support for the accurate judgment of the annular flow regime.
Low Cost Gas Turbine Off-Design Prediction Technique
NASA Astrophysics Data System (ADS)
Martinjako, Jeremy
This thesis seeks to further explore off-design point operation of gas turbines and to examine the capabilities of GasTurb 12 as a tool for off-design analysis. It is a continuation of previous thesis work which initially explored the capabilities of GasTurb 12. The research is conducted in order to: 1) validate GasTurb 12 and, 2) predict off-design performance of the Garrett GTCP85-98D located at the Arizona State University Tempe campus. GasTurb 12 is validated as an off-design point tool by using the program to predict performance of an LM2500+ marine gas turbine. Haglind and Elmegaard (2009) published a paper detailing a second off-design point method and it includes the manufacturer's off-design point data for the LM2500+. GasTurb 12 is used to predict off-design point performance of the LM2500+ and compared to the manufacturer's data. The GasTurb 12 predictions show good correlation. Garrett has published specification data for the GTCP85-98D. This specification data is analyzed to determine the design point and to comment on off-design trends. Arizona State University GTCP85-98D off-design experimental data is evaluated. Trends presented in the data are commented on and explained. The trends match the expected behavior demonstrated in the specification data for the same gas turbine system. It was originally intended that a model of the GTCP85-98D be constructed in GasTurb 12 and used to predict off-design performance. The prediction would be compared to collected experimental data. This is not possible because the free version of GasTurb 12 used in this research does not have a module to model a single spool turboshaft. This module needs to be purchased for this analysis.
A bubble-based microfluidic gas sensor for gas chromatographs.
Bulbul, Ashrafuzzaman; Kim, Hanseup
2015-01-07
We report a new proof-of-concept bubble-based gas sensor for a gas chromatography system, which utilizes the unique relationship between the diameters of the produced bubbles with the gas types and mixture ratios as a sensing element. The bubble-based gas sensor consists of gas and liquid channels as well as a nozzle to produce gas bubbles through a micro-structure. It utilizes custom-developed software and an optical camera to statistically analyze the diameters of the produced bubbles in flow. The fabricated gas sensor showed that five types of gases (CO2, He, H2, N2, and CH4) produced (1) unique volumes of 0.44, 0.74, 1.03, 1.28, and 1.42 nL (0%, 68%, 134%, 191%, and 223% higher than that of CO2) and (2) characteristic linear expansion coefficients (slope) of 1.38, 2.93, 3.45, 5.06, and 5.44 nL/(kPa (μL s(-1))(-1)). The gas sensor also demonstrated that (3) different gas mixture ratios of CO2 : N2 (100 : 0, 80 : 20, 50 : 50, 20 : 80 and 0 : 100) generated characteristic bubble diameters of 48.95, 77.99, 71.00, 78.53 and 99.50 μm, resulting in a linear coefficient of 10.26 μm (μL s(-1))(-1). It (4) successfully identified an injection (0.01 μL) of pentane (C5) into a continuous carrier gas stream of helium (He) by monitoring bubble diameters and creating a chromatogram and demonstrated (5) the output stability within only 5.60% variation in 67 tests over a month.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Ridgley, J.L.; Condon, S.M.; Hatch, J.R.
2013-01-01
Four assessment units (AU) were defined in the Fruitland TPS. Of the four AUs, one consists of conventional gas accumulations and the other three are continuous-type gas accumulations: Tertiary Conventional Gas AU, Pictured Cliffs Continuous Gas AU, Basin Fruitland Coalbed Gas (CBG) AU, and Fruitland Fairway CBG AU. No oil resources that have the potential for additions to reserves in the next 30 years were estimated for this TPS. Gas resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 29.3 trillion cubic feet of gas (TCFG). Of this amount, 23.58 TCFG will come from coal-bed gas accumulations and 83.1 percent of this total is estimated to come from the Basin Fruitland CBG AU. The remaining 5.72 TCFG is allocated to continuous-type gas accumulations (5.64 TCFG) and conventional gas accumulations (0.08 TCFG). Although the Fruitland Fairway CBG AU has produced the most significant amount of coal-bed gas to date, the area of the AU is limited. New potentially productive wells will come from infill drilling, and the number of these wells will be limited by effective drainage area. Total natural gas liquids (NGL) that have the potential for additions to reserves in the next 30 years are estimated at a mean of 17.76 million barrels. Of this amount, 16.92 million barrels will come from the Pictured Cliffs Continuous Gas AU and the remainder from the Tertiary Conventional Gas AU.
A Tale of Two Regions: Landscape Ecological Planning for Shale Gas Energy Futures
NASA Astrophysics Data System (ADS)
Murtha, T., Jr.; Schroth, O.; Orland, B.; Goldberg, L.; Mazurczyk, T.
2015-12-01
As we increasingly embrace deep shale gas deposits to meet global energy demands new and dispersed local and regional policy and planning challenges emerge. Even in regions with long histories of energy extraction, such as coal, shale gas and the infrastructure needed to produce the gas and transport it to market offers uniquely complex transformations in land use and landcover not previously experienced. These transformations are fast paced, dispersed and can overwhelm local and regional planning and regulatory processes. Coupled to these transformations is a structural confounding factor. While extraction and testing are carried out locally, regulation and decision-making is multilayered, often influenced by national and international factors. Using a geodesign framework, this paper applies a set of geospatial landscape ecological planning tools in two shale gas settings. First, we describe and detail a series of ongoing studies and tools that we have developed for communities in the Marcellus Shale region of the eastern United States, specifically the northern tier of Pennsylvania. Second, we apply a subset of these tools to potential gas development areas of the Fylde region in Lancashire, United Kingdom. For the past five years we have tested, applied and refined a set of place based and data driven geospatial models for forecasting, envisioning, analyzing and evaluating shale gas activities in northern Pennsylvania. These models are continuously compared to important landscape ecological planning challenges and priorities in the region, e.g. visual and cultural resource preservation. Adapting and applying these tools to a different landscape allow us to not only isolate and define important regulatory and policy exigencies in each specific setting, but also to develop and refine these models for broader application. As we continue to explore increasingly complex energy solutions globally, we need an equally complex comparative set of landscape ecological planning tools to inform policy, design and regional planning. Adapting tools and techniques developed in Pennsylvania where shale gas extraction is ongoing to Lancashire, where industry is still in the exploratory phase offers a key opportunity to test and refine more generalizable models.
10 CFR 590.407 - Reports of changes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Opinions and Orders § 590.407 Reports of changes. Any person authorized to import or export natural gas has a continuing obligation to give the...
Map of assessed continuous (unconventional) oil resources in the United States, 2014
,; Biewick, Laura R. H.
2015-01-01
The U.S. Geological Survey (USGS) conducts quantitative assessments of potential oil and gas resources of the onshore United States and associated coastal State waters. Since 2000, the USGS has completed assessments of continuous (unconventional) resources in the United States based on geologic studies and analysis of well-production data and has compiled digital maps of the assessment units classified into four categories: shale gas, tight gas, coalbed gas, and shale oil or tight oil (continuous oil). This is the fourth digital map product in a series of USGS unconventional oil and gas resource maps; its focus being shale-oil or tight-oil (continuous-oil) assessments. The map plate included in this report can be printed in hardcopy form or downloaded in a Geographic Information System (GIS) data package, which includes an ArcGIS ArcMap document (.mxd), geodatabase (.gdb), and a published map file (.pmf). Supporting geologic studies of total petroleum systems and assessment units, as well as studies of the methodology used in the assessment of continuous-oil resources in the United States, are listed with hyperlinks in table 1. Assessment results and geologic reports are available at the USGS websitehttp://energy.usgs.gov/OilGas/AssessmentsData/NationalOilGasAssessment.aspx.
NASA Astrophysics Data System (ADS)
Reba, M. L.; Fong, B.; Adviento-Borbe, A.; Runkle, B.
2016-12-01
The subtropical humid mid-south region produces nearly 75% of US rice. Rice cultivation contributes higher amounts of GHG emissions (CO2, CH4, and N2O) due to flooded field conditions. Accurate measurements of gas fluxes are important to regional and global climate models. A comparison between eddy covariance and static vented flux chamber measurement techniques is presented. These measurements were collected in two NE Arkansas commercial rice fields in 2015 and 2016 production seasons under two irrigation treatments: Alternate Wetting and Drying (AWD) and continuous flood (CF) irrigation. AWD can reduce GHG emissions and water use compared to CF by introducing aerobic conditions that reduce methanogen activity and drained conditions decrease water loss due to seepage or evapotranspiration. N2O was measured only with vented chambers, while CO2 and CH4 were measured with both techniques. In the vented flux chamber technique, headspace gas sampling occurred at least once a week every 20 minutes for one hour of chamber closure. Gas Chromatograph equipped with ECD and FID were used to analyze gas concentrations. Eddy covariance used high frequency measurements wind and concentration measurements to determine fluxes. Chamber measurements were found to be more sensitive during seedling and early vegetative growth while eddy covariance was more sensitive after canopy closure during mid-vegetative to reproductive growth. Unlike eddy covariance which measured net CO2 exchange, flux chamber method measured only CO2 ecosystem respiration because flux measurements occurred using an opaque chamber material.
NASA Technical Reports Server (NTRS)
1989-01-01
The M200 originated in the 1970's under an Ames Research Center/Stanford University contract to develop a small, lightweight gas analyzer for Viking Landers. Although the unit was not used on the spacecraft, it was further developed by The National Institute for Occupational Safety and Health (NIOSH). Three researchers from the project later formed Microsensor Technology, Inc. (MTI) to commercialize the analyzer. The original version (Micromonitor 500) was introduced in 1982, and the M200 in 1988. The M200, a more advanced version, features dual gas chromatograph which separate a gaseous mixture into components and measure concentrations of each gas. It is useful for monitoring gas leaks, chemical spills, etc. Many analyses are completed in less than 30 seconds, and a wide range of mixtures can be analyzed.
Majid, Ahmad A A; Wu, David T; Koh, Carolyn A
2017-10-24
In situ rheological measurements for clathrate hydrate slurries were performed using a high pressure rheometer to determine the effect of hydrate particles on the viscosity and transportability of these slurries. These measurements were conducted using a well-characterized model water-in-oil emulsion ( Delgado-Linares et al. Model Water in-Oil Emulsions for Gas Hydrate Studies in Oil Continuous Systems . Energy Fuels 2013 , 27 , 4564 - 4573 ). The emulsion consists of a model liquid hydrocarbon, water, and a surfactant mixture of sorbitane monooleate 80 (Span 80) and sodium di-2-ethylhexylsulfosuccinate (Aerosol OT, AOT). This emulsion was used as an analog to water-in-crude oil (w/o) emulsions and provides reproducible results. The flow properties of the model w/o emulsion prior to hydrate formation were investigated in terms of several parameters including water percentage, temperature and pressure. A general equation that describes the viscosity of the emulsion as a function of the aforementioned parameters was developed. This general equation was able to predict the viscosity of a saturated emulsion at various temperatures and water percentages to within ±13% error. The general equation was then used to analyze the effect of hydrate formation on the transportability of gas hydrate slurries. As for hydrate slurries investigation, measurements were performed using methane gas as the hydrate former and a straight vane impeller as a stirring system. Tests were conducted at constant temperature and pressure (1 °C and 1500 psig of methane) and water percentages ranging from 5 to 30 vol %. Results of this work were analyzed and presented in terms of relative values, i.e., viscosities of the slurries relative to the viscosities of the continuous phase at similar temperature and pressure. In this work, a correlation to predict the relative viscosity of a hydrate slurry at various hydrate volume fractions was developed. Analysis of the developed correlation showed that the model was able to predict the relative viscosity of a hydrate slurry to within ±17% error.
Laser photoacoustic sensor for air toxicity measurements
NASA Astrophysics Data System (ADS)
Prasad, Coorg R.; Lei, Jie; Shi, Wenhui; Li, Guangkun; Dunayevskiy, Ilya; Patel, C. Kumar N.
2012-06-01
US EPA's Clean Air Act lists 187 hazardous air pollutants (HAP) or airborne toxics that are considered especially harmful to health, and hence the measurement of their concentration is of great importance. Numerous sensor systems have been reported for measuring these toxic gases and vapors. However, most of these sensors are specific to a single gas or able to measure only a few of them. Thus a sensor capable of measuring many of the toxic gases simultaneously is desirable. Laser photoacoustic spectroscopy (LPAS) sensors have the potential for true broadband measurement when used in conjunction with one or more widely tunable laser sources. An LPAS gas analyzer equipped with a continuous wave, room temperature IR Quantum Cascade Laser tunable over the wavelength range of 9.4 μm to 9.7 μm was used for continuous real-time measurements of multiple gases/chemical components. An external cavity grating tuner was used to generate several (75) narrow line output wavelengths to conduct photoacoustic absorption measurements of gas mixtures. We have measured various HAPs such as Benzene, Formaldehyde, and Acetaldehyde in the presence of atmospheric interferents water vapor, and carbon dioxide. Using the preliminary spectral pattern recognition algorithm, we have shown our ability to measure all these chemical compounds simultaneously in under 3 minutes. Sensitivity levels of a few part-per-billion (ppb) were achieved with several of the measured compounds with the preliminary laboratory system.
Dubiel, Russell F.; Pitman, Janet K.; Pearson, Ofori N.; Pearson, Krystal; Kinney, Scott A.; Lewan, Michael D.; Burke, Lauri; Biewick, Laura; Charpentier, Ronald R.; Cook, Troy A.; Klett, Timothy R.; Pollastro, Richard M.; Schenk, Christopher J.
2012-01-01
Using a geology-based assessment methodology, the U.S. Geological Survey assessed means of (1) 141 million barrels of oil (MMBO), 502 billion cubic feet of natural gas (BCFG), and 16 million barrels of natural gas liquids (MMBNGL) in the conventional Eagle Ford Updip Sandstone Oil and Gas Assessment Unit (AU); (2) 853 MMBO, 1,707 BCFG, and 34 MMBNGL in the continuous Eagle Ford Shale Oil AU; and (3) 50,219 BCFG and 2,009 MMBNGL in the continuous Eagle Ford Shale Gas AU in onshore lands and State waters of the Gulf Coast.
Ren, Hong; Wang, Ye; Chen, Ming-liang; Yuan, Zheng-an; Li, Yan-ting; Huang, Pu; Hu, Jia-yu
2013-07-01
To systemically analyze the epidemiological characteristics, molecular markers of circulating group A Streptococcus (GAS) isolates and the incidence trend of scarlet fever in Shanghai from 2005 to 2012 as well as to explore the practice of GAS isolates surveillance program and the combined mathematical model in the early warning of scarlet fever. The morbidity series of scarlet fever were retrieved to analyze and fit the combined mathematical model which comprised an autoregressive integrated moving average (ARIMA) model and a neural network. GAS isolates surveillances programs were implemented on community healthy population, using the emm typing and superantigens detecting method in Shanghai during the epidemic period of scarlet fever in 2008, 2010 and 2012. The standardized prevalence of GAS isolates was estimated with the demographic data. From 2005 to 2012, there were a total of 9410 scarlet fever cases reported in Shanghai including local registered residents and immigrant population, showing that the distribution of patients as sporadic. The morbidity kept rising with seasonal and periodical variations and the peak was in 2011. The average morbidity was 6.012 per 100 000 persons. Morbidity in the the suburban was significantly higher than that in the urban areas. Children at 4 to 8 years old were easy to be involved. The mean error rate of single ARIMA model,ARIMA-GRNN and back propagation artificial neural network combined model were 0.268, 0.432 and 0.131 respectively. The predicted incidence of scarlet fever in 2013 would keep fluctuating within a narrow range from 0.446 to 3.467 per 100 000 persons. A total number of 4409 throat swab samples were collected through the GAS isolates surveillance programs in 2008, 2010 and 2012. The standardized prevalence of GAS isolates in each year were 0.000%, 0.000% and 1.092%. 18 GAS isolates were identified and 15 isolates (83.33%)belonged to emm 12.0. The morbidity of scarlet fever would continue to maintain an upward trend in Shanghai and the techniques used in GAS isolates surveillance program and in the combined mathematical model could be applied for the early warning system on scarlet fever.
Method for production of magnesium
Diaz, Alexander F.; Howard, Jack B.; Modestino, Anthony J.; Peters, William A.
1998-01-01
A continuous process for the production of elemental magnesium is described. Magnesium is made from magnesium oxide and a light hydrocarbon gas. In the process, a feed stream of the magnesium oxide and gas is continuously fed into a reaction zone. There the magnesium oxide and gas are reacted at a temperature of about 1400.degree. C. or greater in the reaction zone to provide a continuous product stream of reaction products, which include elemental magnesium. The product stream is continuously quenched after leaving the reaction zone, and the elemental magnesium is separated from other reaction products.
Method for production of magnesium
Diaz, A.F.; Howard, J.B.; Modestino, A.J.; Peters, W.A.
1998-07-21
A continuous process for the production of elemental magnesium is described. Magnesium is made from magnesium oxide and a light hydrocarbon gas. In the process, a feed stream of the magnesium oxide and gas is continuously fed into a reaction zone. There the magnesium oxide and gas are reacted at a temperature of about 1400 C or greater in the reaction zone to provide a continuous product stream of reaction products, which include elemental magnesium. The product stream is continuously quenched after leaving the reaction zone, and the elemental magnesium is separated from other reaction products. 12 figs.
NASA Astrophysics Data System (ADS)
Guha, Jayanta; Lu, Huan-Zhang; Gagnon, Michel
1990-03-01
A quadrupole mass spectrometer and a solid probe which can be inserted directly into the ionization chamber have been used to analyze gas compositions of fluid inclusions. The probe holds a solid sample which can be heated continuously or stepwise from 30 to 750°C using variable heating rates. The decrepitated gas is released directly into the spectrometer source, thus reducing contamination. A Single Ion Monitoring mode program is used for the analysis, which is capable of detecting 26 preselected gases separately, and gases at picogram levels have been analyzed with this method. Each single burst of inclusions is detected and analyzed separately using a surface area integrator, and the computer program automatically traces the baseline above the background. Gas ratios are calculated for single bursts, or bursts over different ranges of temperature, as well as the sum of the total range. Routine petrographic and microthermometric analyses are used to determine the different generations of inclusions and their decrepitation temperatures. Then tiny pieces of the doubly polished section containing representative fluid inclusions or inclusions targeted for analysis are cut and introduced into the solid probe and heated accordingly. The principal gas species which have been analyzed are CO 2, CON 2 (not discriminated), H 2O, H 2S, and nearly all light hydrocarbons. Fluid inclusions from different host minerals such as quartz, fluorite, barite, and sulfides have also been analyzed. The most important advantage of this method is that analytical results can be correlated with specific inclusion types since a small amount of sample material is required which makes it easier to choose specific areas from doubly polished sections. Another advantage is its capability to match the presence of gases in inclusions in quartz with those in associated sulfides, thereby confirming or denying that similar fluids were trapped by both the minerals. More tests are underway to examine the use of fluid inclusion data from sulfides. Preliminary tests on samples from an Archean gold deposit indicate the potential of this method, not only to detect the presence of different gases in the fluid, but also to determine gas ratios of fluid inclusions rapidly and fairly accurately. It has previously been established through alteration assemblage studies that CO 2H 2O ratios of the fluid decreased outwards from the gold-bearing zones and the new fluid inclusion data confirm this. This method also detected the presence of other gases such as CO/N 2, CH 4, C 2H 6, and H 2S, indicating a multi-component C-O-N-H-S system. This method can be useful for both reconnaissance and detailed investigations where gas compositions of fluid inclusions are important for the understanding of fluid evolution processes.
Johnson, Dwight R; Kurlan, Roger; Leckman, James; Kaplan, Edward L
2010-02-15
Determination of an immune response to group A Streptococcus (GAS) antigens, frequently anti-streptolysin O and anti-DNase B, is crucial for documentation of bona fide GAS infection. Although the importance of immunologic confirmation of infection is widely accepted, the immediate and long-term immunokinetics of the human antibody response are incompletely documented and poorly understood. Pediatric study participants (n = 160) were followed during a 2-year study with monthly throat cultures (n = 3491) and blood samples (n = 1679) obtained every 13 weeks. Recovered GAS were characterized; serum anti-streptolysin O and anti-DNase B antibody titers were determined. Antibody titers and GAS culture results were temporally correlated and analyzed. The analyses clearly document, in some instances for the first time, that an increase in antibody titer more accurately defines infection than does an absolute titer (eg, "upper limit of normal"), that antibody titers can remain elevated for many months even without GAS, and that some individuals may harbor GAS continuously for months or years without symptoms of infection and without an associated immune response. Measuring 2 different antibodies is more accurate in defining infection. Single time-point cultures and single antibody titers are often misleading. Sequential samples more accurately define infection, allowing correlation of titer increases with temporal confirmation of GAS acquisition. Understanding kinetics of the immune response(s) to GAS infection is necessary in formulating accurate clinical diagnostic conclusions, to appropriate design of clinical and epidemiological studies examining the association of GAS with subsequent sequelae, and to providing insight into pathogenetic mechanisms associated with this important human pathogen.
Analysis of trickle-bed reactor for ethanol production from syngas using Clostridium ragsdalei
NASA Astrophysics Data System (ADS)
Devarapalli, Mamatha
The conversion of syngas components (CO, CO2 and H2) to liquid fuels such as ethanol involves complex biochemical reactions catalyzed by a group of acetogens such as Clostridium ljungdahlii, Clostridium carboxidivorans and Clostridium ragsdalei. The low ethanol productivity in this process is associated with the low solubility of gaseous substrates CO and H2 in the fermentation medium. In the present study, a 1-L trickle-bed reactor (TBR) was analyzed to understand its capabilities to improve the mass transfer of syngas in fermentation medium. Further, semi-continuous and continuous syngas fermentations were performed using C. ragsdalei to evaluate the ability of the TBR for ethanol production. In the mass transfer studies, using 6-mm glass beads, it was found that the overall mass transfer coefficient (kLa/V L) increased with the increase in gas flow rate from 5.5 to 130.5 sccm. Further, an increase in the liquid flow rate in the TBR decreased the kLa/VL due to the increase in liquid hold up volume (VL) in the packing. The highest kLa/VL values of 421 h-1 and 178 h-1 were achieved at a gas flow rate of 130.5 sccm for 6-mm and 3-mm glass beads, respectively. Semi-continuous fermentations were performed with repetitive medium replacement in counter-current and co-current modes. In semi-continuous fermentations with syngas consisting of 38% CO, 5% N2, 28.5% CO2 and 28.5% H2 (by volume), the increase in H2 conversion (from 18 to 55%) and uptake (from 0.7 to 2.2 mmol/h) were observed. This increase was attributed to more cell attachment in the packing that reduced CO inhibition to hydrogenase along the column length and increased the H2 uptake. The maximum ethanol produced during counter-current and co-current modes were 3.0 g/L and 5.7 g/L, respectively. In continuous syngas fermentation, the TBR was operated at dilution rates between 0.006 h-1and 0.012 h -1 and gas flow rates between 1.5 sccm and 18.9 sccm. The highest ethanol concentration of 13 g/L was achieved at dilution and gas flow rates of 0.012 h-1 and 18.9 sccm, respectively. The molar ratio of ethanol to acetic acid of 4:1 was obtained during continuous fermentation which was 7.7 times higher than in semi-continuous fermentations. The improvement of the reactor performance in continuous mode gives scope to explore the TBR as a potential bioreactor design for large scale biofuels production.
Molecular wake shield gas analyzer
NASA Technical Reports Server (NTRS)
Hoffman, J. H.
1980-01-01
Techniques for measuring and characterizing the ultrahigh vacuum in the wake of an orbiting spacecraft are studied. A high sensitivity mass spectrometer that contains a double mass analyzer consisting of an open source miniature magnetic sector field neutral gas analyzer and an identical ion analyzer is proposed. These are configured to detect and identify gas and ion species of hydrogen, helium, nitrogen, oxygen, nitric oxide, and carbon dioxide and any other gas or ion species in the 1 to 46 amu mass range. This range covers the normal atmospheric constituents. The sensitivity of the instrument is sufficient to measure ambient gases and ion with a particle density of the order of one per cc. A chemical pump, or getter, is mounted near the entrance aperture of the neutral gas analyzer which integrates the absorption of ambient gases for a selectable period of time for subsequent release and analysis. The sensitivity is realizable for all but rare gases using this technique.
40 CFR Table Nn-2 to Subpart Nn of... - Default Values for Calculation Methodology 2 of This Subpart
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids Pt. 98, Subpt. NN, Table NN-2 Table NN-2 to Subpart NN of Part 98.../Unit) 1 Natural Gas Mscf 0.0544 Propane Barrel 0.241 Normal butane Barrel 0.281 Ethane Barrel 0.170...
Vadlin, Sofia; Åslund, Cecilia; Rehn, Mattias; Nilsson, Kent W
2015-12-01
The objective of the study is to evaluate the psychometric properties of the Gaming Addiction Identification Test (GAIT) and its parent version (GAIT-P), in a representative community sample of adolescents and parents in Västmanland, Sweden. Self-rated and parent-rated gaming addictive symptoms identified by GAIT and GAIT-P were analyzed for frequency of endorsement, internal consistency, concordance, factor structure, prevalence of Internet gaming disorder (IGD), concurrence with the Gaming Addiction Scale for Adolescents, 7-item version (GAS) and the parent version of GAS (GAS-P), and for sex differences. The 12-month prevalence of IGD was found to be 1.3% with GAIT and 2.4% with GAIT-P. Results also indicate promising psychometric results within this population, with high internal consistency, and high concurrent validity with GAS and GAS-P. Concordance between adolescents and parents ratings was high, although moderate in girls. Although exploratory factor analysis indicated poor model fit, it also indicated unidimensionality and high factor loadings in all analyses. GAIT and GAIT-P are suitable for continued use in measuring gaming addiction in adolescents, and, with the additional two items, they now cover all nine IGD criteria. © 2015 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
40 CFR 264.1054 - Standards: Pressure relief devices in gas/vapor service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service. 264.1054 Section 264.1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE... relief devices in gas/vapor service. (a) Except during pressure releases, each pressure relief device in...
49 CFR 192.1007 - What are the required elements of an integrity management plan?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas... threats and risks to its gas distribution pipeline. (2) Consider the information gained from past design...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM...
Soil Gas Dynamics and Microbial Activity in the Unsaturated Zone of a Regulated River
NASA Astrophysics Data System (ADS)
Christensen, H.; Ferencz, S. B.; Cardenas, M. B.; Neilson, B. T.; Bennett, P. C.
2017-12-01
Over 60% of the world's rivers are dammed, and are therefore regulated. In some river systems, river regulation is the dominant factor governing fluid exchange and soil gas dynamics in the hyporheic region and overlying unsaturated zone of the river banks. Where this is the case, it is important to understand the effects that an artificially-induced change in river stage can have on the chemical, plant, and microbial components of the unsaturated zone. Daily releases from an upstream dam cause rapid stage fluctuations in the Lower Colorado River east of Austin, Texas. For this study, we utilized an array of water and gas wells along a transect perpendicular to the river to investigate the biogeochemical process occurring in this mixing zone. The gas wells were installed at several depths up to 1.5 meters, and facilitated the continuous monitoring of soil gases as the pulse percolated through the river bank. Water samples collected from the screened wells penetrated to depths below the water table and were analyzed for nutrients, carbon, and major ions. Additionally, two soil cores were taken at different distances from the river and analyzed for soil moisture and grain size. These cores were also analyzed for microbial activity using the total heterotroph count method and the acetylene inhibition technique, a sensitive method of measuring denitrifying activity. The results provide a detailed picture of soil gas flux and biogeochemical processes in the bank environment in a regulated river. Findings indicate that a river pulse that causes a meter-scale change in river stage causes small, centimeter-scale pulses in the water table. We propose that these conditions create an area of elevated microbial respiration at the base of the unsaturated zone that appears to be decoupled from normal diurnal fluctuations. Along the transect, CO2 concentrations increased with increasing depth down to the water table. CO2 concentrations were highest in the time following a pulse, and the lowest concentrations were recorded following the trough in river stage.
Resource-assessment perspectives for unconventional gas systems
Schmoker, J.W.
2002-01-01
Concepts are described for assessing those unconventional gas systems that can also be defined as continous accumulations. Continuous gas accumulations exist more or less independently of the water column and do not owe their existence directly to the bouyancy of gas in water. They cannot be represented in terms of individual, countable fields or pools delineated by downdip water contacts. For these reasons, traditional resource-assessment methods based on estimating the sizes and numbers of undiscovered discrete fields cannot not be applied to continuous accumulations. Specialized assessment methods are required. Unconventional gas systems that are also continous accumulations include coalbed methane, basin-centered gas, so-called tight gas, fractured shale (and chalk) gas, and gas hydrates. Deep-basin and bacterial gas systems may or may not be continuous accumulations, depending on their geologic setting. Two basic resource-assessment approaches have been employed for continous accumulations. The first approach is based on estimates of gas in place. A volumetric estimate of total gas in place is commonly coupled with an overall recovery factor to narrow the assessment scope from a treatment of gas volumes residing in sedimentary strata to a prediction of potential additions to reserves. The second approach is based on the production performance of continous gas reservoirs, as shown empirically by wells and reservoir-simulation models. In these methods, production characteristics (as opposed to gas in place) are the foundation for forecasts of potential additions to reserves.
Mapping the Fluid Pathways and Permeability Barriers of a Large Gas Hydrate Reservoir
NASA Astrophysics Data System (ADS)
Campbell, A.; Zhang, Y. L.; Sun, L. F.; Saleh, R.; Pun, W.; Bellefleur, G.; Milkereit, B.
2012-12-01
An understanding of the relationship between the physical properties of gas hydrate saturated sedimentary basins aids in the detection, exploration and monitoring one of the world's upcoming energy resources. A large gas hydrate reservoir is located in the MacKenzie Delta of the Canadian Arctic and geophysical logs from the Mallik test site are available for the gas hydrate stability zone (GHSZ) between depths of approximately 850 m to 1100 m. The geophysical data sets from two neighboring boreholes at the Mallik test site are analyzed. Commonly used porosity logs, as well as nuclear magnetic resonance, compressional and Stoneley wave velocity dispersion logs are used to map zones of elevated and severely reduced porosity and permeability respectively. The lateral continuity of horizontal permeability barriers can be further understood with the aid of surface seismic modeling studies. In this integrated study, the behavior of compressional and Stoneley wave velocity dispersion and surface seismic modeling studies are used to identify the fluid pathways and permeability barriers of the gas hydrate reservoir. The results are compared with known nuclear magnetic resonance-derived permeability values. The aim of investigating this heterogeneous medium is to map the fluid pathways and the associated permeability barriers throughout the gas hydrate stability zone. This provides a framework for an understanding of the long-term dissociation of gas hydrates along vertical and horizontal pathways, and will improve the knowledge pertaining to the production of such a promising energy source.
Ambient Field Analysis at Groningen Gas Field
NASA Astrophysics Data System (ADS)
Spica, Z.; Nakata, N.; Beroza, G. C.
2016-12-01
We analyze continuous ambient-field data at Groningen gas field (Netherlands) through cross-correlation processing. The Groningen array is composed of 75 shallow boreholes with 6 km spacing, which contain a 3C surface accelerometer and four 5-Hz 3C borehole geophones spaced at 50 m depth intervals. We successfully retrieve coherent waves from ambient seismic field on the 9 components between stations. Results show high SNR signal in the frequency range of 0.125-1 Hz, and the ZZ, ZR, RZ, RR and TT components show much stronger wave energy than other components as expected. This poster discuss the different type of waves retrieved, the utility of the combination of borehole and surface observations, future development as well as the importance to compute the 9 components of the Green's tensor to better understand the wave field propriety with ambient noise.
Ma, Yufei; Yu, Guang; Zhang, Jingbo; Yu, Xin; Sun, Rui; Tittel, Frank K
2015-03-27
A sensitive trace gas sensor platform based on quartz-enhanced photoacoustic spectroscopy (QEPAS) is reported. A 1.395 μm continuous wave (CW), distributed feedback pigtailed diode laser was used as the excitation source and H2O was selected as the target analyte. Two kinds of quartz tuning forks (QTFs) with a resonant frequency (f0) of 30.72 kHz and 38 kHz were employed for the first time as an acoustic wave transducer, respectively for QEPAS instead of a standard QTF with a f0 of 32.768 kHz. The QEPAS sensor performance using the three different QTFs was experimentally investigated and theoretically analyzed. A minimum detection limit of 5.9 ppmv and 4.3 ppmv was achieved for f0 of 32.768 kHz and 30.72 kHz, respectively.
Neural net controlled tag gas sampling system for nuclear reactors
Gross, Kenneth C.; Laug, Matthew T.; Lambert, John D. B.; Herzog, James P.
1997-01-01
A method and system for providing a tag gas identifier to a nuclear fuel rod and analyze escaped tag gas to identify a particular failed nuclear fuel rod. The method and system include disposing a unique tag gas composition into a plenum of a nuclear fuel rod, monitoring gamma ray activity, analyzing gamma ray signals to assess whether a nuclear fuel rod has failed and is emitting tag gas, activating a tag gas sampling and analysis system upon sensing tag gas emission from a failed nuclear rod and evaluating the escaped tag gas to identify the particular failed nuclear fuel rod.
Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.
Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R
2005-11-01
An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.
Hall, David O; Fernández, F G Acién; Guerrero, E Cañizares; Rao, K Krishna; Grima, E Molina
2003-04-05
The production of the microalga Phaeodactylum tricornutum in an outdoor helical reactor was analyzed. First, fluid dynamics, mass-transfer capability, and mixing of the reactor was evaluated at different superficial gas velocities. Performance of the reactor was controlled by power input per culture volume. A maximum liquid velocity of 0.32 m s(-1) and mass transfer coefficient of 0.006 s(-1) were measured at 3200 W m(-3). A model of the influence of superficial gas velocity on the following reactor parameters was proposed: gas hold-up, induced liquid velocity, and mass transfer coefficient, with the accuracy of the model being demonstrated. Second, the influence of superficial gas velocity on the yield of the culture was evaluated in discontinuous and continuous cultures. Mean daily values of culture parameters, including dissolved oxygen, biomass concentration, chlorophyll fluorescence (F(v)/F(m) ratio), growth rate, biomass productivity, and photosynthetic efficiency, were determined. Different growth curves were measured when the superficial gas velocity was modified-the higher the superficial gas velocity, the higher the yield of the system. In continuous mode, biomass productivity increased by 35%, from 1.02 to 1.38 g L(-1) d(-1), when the superficial gas velocity increased from 0.27 to 0.41 m s(-1). Maximal growth rates of 0.068 h(-1), biomass productivities up to 1.4 g L(-1) d(-1), and photosynthetic efficiency of up to 15% were obtained at the higher superficial gas velocity of 0.41 m s(-1). The fluorescence parameter, F(v)/F(m), which reflects the maximal efficiency of PSII photochemistry, showed that the cultures were stressed at average irradiances within the culture higher than 280 microE m(-2) s(-1) at every superficial gas velocity. For nonstressed cultures, the yield of the system was a function of average irradiance inside the culture, with the superficial gas velocity determining this relationship. When superficial gas velocity was increased, higher growth rates, biomass productivities, and photosynthetic efficiencies were obtained for similar average irradiance values. The higher the superficial gas velocity, the higher the liquid velocity, with this increase enhancing the movement of the cells inside the culture. In this way the efficiency of the cells increased and higher biomass concentrations and productivities were reached for the same solar irradiance. Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 82: 62-73, 2003.
Gas absorption/desorption temperature-differential engine
NASA Technical Reports Server (NTRS)
Miller, C. G.
1981-01-01
Continuously operating compressor system converts 90 percent of gas-turbine plant energy to electricity. Conventional plants work in batch mode, operating at 40 percent efficiency. Compressor uses metal hydride matrix on outside of rotating drum to generate working gas, hydrogen. Rolling valve seals allow continuous work. During operation, gas is absorbed, releasing heat, and desorbed with heat gain. System conserves nuclear and fossil fuels, reducing powerplant capital and operating costs.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids Pt. 98, Subpt. NN, Table NN-1 Table NN-1 to Subpart NN of Part 98... CO2emission factor (kg CO2/MMBtu) Natural Gas 1.026 MMBtu/Mscf 53.06 Propane 3.84 MMBtu/bbl 62.87 Normal...
German, Sean R; Edwards, Martin A; Chen, Qianjin; Liu, Yuwen; Luo, Long; White, Henry S
2016-12-12
In this article, we address the fundamental question: "What is the critical size of a single cluster of gas molecules that grows and becomes a stable (or continuously growing) gas bubble during gas evolving reactions?" Electrochemical reactions that produce dissolved gas molecules are ubiquitous in electrochemical technologies, e.g., water electrolysis, photoelectrochemistry, chlorine production, corrosion, and often lead to the formation of gaseous bubbles. Herein, we demonstrate that electrochemical measurements of the dissolved gas concentration, at the instant prior to nucleation of an individual nanobubble of H 2 , N 2 , or O 2 at a Pt nanodisk electrode, can be analyzed using classical thermodynamic relationships (Henry's law and the Young-Laplace equation - including non-ideal corrections) to provide an estimate of the size of the gas bubble nucleus that grows into a stable bubble. We further demonstrate that this critical nucleus size is independent of the radius of the Pt nanodisk employed (<100 nm radius), and weakly dependent on the nature of the gas. For example, the measured critical surface concentration of H 2 of ∼0.23 M at the instant of bubble formation corresponds to a critical H 2 nucleus that has a radius of ∼3.6 nm, an internal pressure of ∼350 atm, and contains ∼1700 H 2 molecules. The data are consistent with stochastic fluctuations in the density of dissolved gas, at or near the Pt/solution interface, controlling the rate of bubble nucleation. We discuss the growth of the nucleus as a diffusion-limited process and how that process is affected by proximity to an electrode producing ∼10 11 gas molecules per second. Our study demonstrates the advantages of studying a single-entity, i.e., an individual nanobubble, in understanding and quantifying complex physicochemical phenomena.
Wang, Lixin; Caylor, Kelly K; Dragoni, Danilo
2009-02-01
The (18)O and (2)H of water vapor serve as powerful tracers of hydrological processes. The typical method for determining water vapor delta(18)O and delta(2)H involves cryogenic trapping and isotope ratio mass spectrometry. Even with recent technical advances, these methods cannot resolve vapor composition at high temporal resolutions. In recent years, a few groups have developed continuous laser absorption spectroscopy (LAS) approaches for measuring delta(18)O and delta(2)H which achieve accuracy levels similar to those of lab-based mass spectrometry methods. Unfortunately, most LAS systems need cryogenic cooling and constant calibration to a reference gas, and have substantial power requirements, making them unsuitable for long-term field deployment at remote field sites. A new method called Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) has been developed which requires extremely low-energy consumption and neither reference gas nor cryogenic cooling. In this report, we develop a relatively simple pumping system coupled to a dew point generator to calibrate an ICOS-based instrument (Los Gatos Research Water Vapor Isotope Analyzer (WVIA) DLT-100) under various pressures using liquid water with known isotopic signatures. Results show that the WVIA can be successfully calibrated using this customized system for different pressure settings, which ensure that this instrument can be combined with other gas-sampling systems. The precisions of this instrument and the associated calibration method can reach approximately 0.08 per thousand for delta(18)O and approximately 0.4 per thousand for delta(2)H. Compared with conventional mass spectrometry and other LAS-based methods, the OA-ICOS technique provides a promising alternative tool for continuous water vapor isotopic measurements in field deployments. Copyright 2009 John Wiley & Sons, Ltd.
Ryder, Robert T.; Ruppert, Leslie F.; Ryder, Robert T.
2014-01-01
Both conventional oil and gas resources and continuous (unconventional) gas resources are present in the UticaLower Paleozoic TPS. Conventional oil and gas resources in the Utica-Lower Paleozoic TPS were assessed by the U.S. Geological Survey (USGS) in 2002 in the following assessment units (AU): (1) the Lower Paleozoic Carbonates in Thrust Belt AU, (2) the Knox Unconformity AU, (3) the Black River-Trenton Hydrothermal Dolomite AU, and (4) the Lockport Dolomite AU. The total estimated undiscovered oil and gas resources for these four AUs, at a mean value, was about 46 million barrels of oil (MMBO) and about 3 trillion cubic feet of gas (TCFG), respectively. In contrast, continuous (unconventional) gas resources in the TPS were assessed by the USGS in 2002 in four AUs associated with the “Clinton” sandstone, Medina sandstone, Medina Group sandstones, Tuscarora Sandstone, and sandstones in the Queenston Shale. The total estimated undiscovered gas for these four AUs, at a mean value, was about 26.8 TCFG. A hypothetical Utica Shale AU for oil(?) and continuous gas is identified in this report. In 2012, the Utica Shale was recognized by the USGS as a continuous AU and was assessed by Kirschbaum and others (2012).
On Road Study of Colorado Front Range Greenhouse Gases Distribution and Sources
NASA Astrophysics Data System (ADS)
Petron, G.; Hirsch, A.; Trainer, M. K.; Karion, A.; Kofler, J.; Sweeney, C.; Andrews, A.; Kolodzey, W.; Miller, B. R.; Miller, L.; Montzka, S. A.; Kitzis, D. R.; Patrick, L.; Frost, G. J.; Ryerson, T. B.; Robers, J. M.; Tans, P.
2008-12-01
The Global Monitoring Division and Chemical Sciences Division of the NOAA Earth System Research Laboratory have teamed up over the summer 2008 to experiment with a new measurement strategy to characterize greenhouse gases distribution and sources in the Colorado Front Range. Combining expertise in greenhouse gases measurements and in local to regional scales air quality study intensive campaigns, we have built the 'Hybrid Lab'. A continuous CO2 and CH4 cavity ring down spectroscopic analyzer (Picarro, Inc.), a CO gas-filter correlation instrument (Thermo Environmental, Inc.) and a continuous UV absorption ozone monitor (2B Technologies, Inc., model 202SC) have been installed securely onboard a 2006 Toyota Prius Hybrid vehicle with an inlet bringing in outside air from a few meters above the ground. To better characterize point and distributed sources, air samples were taken with a Portable Flask Package (PFP) for later multiple species analysis in the lab. A GPS unit hooked up to the ozone analyzer and another one installed on the PFP kept track of our location allowing us to map measured concentrations on the driving route using Google Earth. The Hybrid Lab went out for several drives in the vicinity of the NOAA Boulder Atmospheric Observatory (BAO) tall tower located in Erie, CO and covering areas from Boulder, Denver, Longmont, Fort Collins and Greeley. Enhancements in CO2, CO and destruction of ozone mainly reflect emissions from traffic. Methane enhancements however are clearly correlated with nearby point sources (landfill, feedlot, natural gas compressor ...) or with larger scale air masses advected from the NE Colorado, where oil and gas drilling operations are widespread. The multiple species analysis (hydrocarbons, CFCs, HFCs) of the air samples collected along the way bring insightful information about the methane sources at play. We will present results of the analysis and interpretation of the Hybrid Lab Front Range Study and conclude with perspectives on how we will adapt the measurement strategy to study CO2 anthropogenic emissions in Denver Basin.
a Mini Multi-Gas Detection System Based on Infrared Principle
NASA Astrophysics Data System (ADS)
Zhijian, Xie; Qiulin, Tan
2006-12-01
To counter the problems of gas accidents in coal mines, family safety resulted from using gas, a new infrared detection system with integration and miniaturization has been developed. The infrared detection optics principle used in developing this system is mainly analyzed. The idea that multi gas detection is introduced and guided through analyzing single gas detection is got across. Through researching the design of cell structure, the cell with integration and miniaturization has been devised. The way of data transmission on Controller Area Network (CAN) bus is explained. By taking Single-Chip Microcomputer (SCM) as intelligence handling, the functional block diagram of gas detection system is designed with its hardware and software system analyzed and devised. This system designed has reached the technology requirement of lower power consumption, mini-volume, big measure range, and able to realize multi-gas detection.
40 CFR 60.697 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... shall maintain continuous records of the temperature of the gas stream in the combustion zone of the... of an affected facility that uses a catalytic incinerator shall maintain continuous records of the... continuous records of the VOC concentration level or reading of organics of the control device outlet gas...
40 CFR 60.697 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... shall maintain continuous records of the temperature of the gas stream in the combustion zone of the... of an affected facility that uses a catalytic incinerator shall maintain continuous records of the... continuous records of the VOC concentration level or reading of organics of the control device outlet gas...
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.613A-1 Post-1974 limitations on percentage depletion in case of oil and gas wells; general...
40 CFR 80.33 - Controls applicable to natural gas retailers and wholesale purchaser-consumers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Controls applicable to natural gas... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Controls and Prohibitions § 80.33 Controls applicable to natural gas retailers and wholesale purchaser-consumers. (a) After...
40 CFR 80.33 - Controls applicable to natural gas retailers and wholesale purchaser-consumers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Controls applicable to natural gas... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Controls and Prohibitions § 80.33 Controls applicable to natural gas retailers and wholesale purchaser-consumers. (a) After...
40 CFR 80.33 - Controls applicable to natural gas retailers and wholesale purchaser-consumers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Controls applicable to natural gas... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Controls and Prohibitions § 80.33 Controls applicable to natural gas retailers and wholesale purchaser-consumers. (a) After...
40 CFR 60.5375 - What standards apply to gas well affected facilities?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What standards apply to gas well affected facilities? 60.5375 Section 60.5375 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natural Gas...
40 CFR 60.5375 - What standards apply to gas well affected facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What standards apply to gas well affected facilities? 60.5375 Section 60.5375 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Crude Oil and Natural Gas...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1015 What must...
Chemical vapor deposition of epitaxial silicon
Berkman, Samuel
1984-01-01
A single chamber continuous chemical vapor deposition (CVD) reactor is described for depositing continuously on flat substrates, for example, epitaxial layers of semiconductor materials. The single chamber reactor is formed into three separate zones by baffles or tubes carrying chemical source material and a carrier gas in one gas stream and hydrogen gas in the other stream without interaction while the wafers are heated to deposition temperature. Diffusion of the two gas streams on heated wafers effects the epitaxial deposition in the intermediate zone and the wafers are cooled in the final zone by coolant gases. A CVD reactor for batch processing is also described embodying the deposition principles of the continuous reactor.
NASA Technical Reports Server (NTRS)
Kavaya, M. J. (Inventor)
1981-01-01
A Stark effect spectrophone using a pulsed or continuous wave laser having a beam with one or more absorption lines of a constituent of an unknown gas is described. The laser beam is directed through windows of a closed cell while the unknown gas to be modified flows continuously through the cell between electric field plates disposed in the cell on opposite sides of the beam path through the cell. When the beam is pulsed, energy absorbed by the gas increases at each point along the beam path according to the spectral lines of the constituents of the gas for the particular field strengths at those points. The pressure measurement at each point during each pulse of energy yields a plot of absorption as a function of electric field for simultaneous detection of the gas constituents. Provision for signal averaging and modulation is included.
Flow-based ammonia gas analyzer with an open channel scrubber for indoor environments.
Ohira, Shin-Ichi; Heima, Minako; Yamasaki, Takayuki; Tanaka, Toshinori; Koga, Tomoko; Toda, Kei
2013-11-15
A robust and fully automated indoor ammonia gas monitoring system with an open channel scrubber (OCS) was developed. The sample gas channel dimensions, hydrophilic surface treatment to produce a thin absorbing solution layer, and solution flow rate of the OCS were optimized to connect the OCS as in-line gas collector and avoid sample humidity effects. The OCS effluent containing absorbed ammonia in sample gas was injected into a derivatization solution flow. Derivatization was achieved with o-phthalaldehyde and sulfite in pH 11 buffer solution. The product, 1-sulfonateisoindole, is detected with a home-made fluorescence detector. The limit of detection of the analyzer based on three times the standard deviation of baseline noise was 0.9 ppbv. Sample gas could be analyzed 40 times per hour. Furthermore, relative humidity of up to 90% did not interfere considerably with the analyzer. Interference from amines was not observed. The developed gas analysis system was calibrated using a solution-based method. The system was used to analyze ammonia in an indoor environment along with an off-site method, traditional impinger gas collection followed by ion chromatographic analysis, for comparison. The results obtained using both methods agreed well. Therefore, the developed system can perform on-site monitoring of ammonia in indoor environments with improved time resolution compared with that of other methods. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.937 What is a...
Neural net controlled tag gas sampling system for nuclear reactors
Gross, K.C.; Laug, M.T.; Lambert, J.B.; Herzog, J.P.
1997-02-11
A method and system are disclosed for providing a tag gas identifier to a nuclear fuel rod and analyze escaped tag gas to identify a particular failed nuclear fuel rod. The method and system include disposing a unique tag gas composition into a plenum of a nuclear fuel rod, monitoring gamma ray activity, analyzing gamma ray signals to assess whether a nuclear fuel rod has failed and is emitting tag gas, activating a tag gas sampling and analysis system upon sensing tag gas emission from a failed nuclear rod and evaluating the escaped tag gas to identify the particular failed nuclear fuel rod. 12 figs.
Long-term greenhouse gas measurements from aircraft
NASA Astrophysics Data System (ADS)
Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.
2013-03-01
In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. Flights typically last 8 h and cover a large area, traveling from Kodiak up to Barrow, Alaska, with altitude profiles near the coast and in the interior. NOAA instrumentation on each flight includes a flask sampling system, a continuous cavity ring-down spectroscopy (CRDS) carbon dioxide (CO2)/methane (CH4)/carbon monoxide (CO)/water vapor (H2O) analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction and present an assessment of analyzer performance over a three-year period. Overall analytical uncertainty of CRDS measurements in 2011 is estimated to be 0.15 ppm, 1.4 ppb, and 5 ppb for CO2, CH4, and CO, respectively, considering short-term precision, calibration uncertainties, and water vapor correction uncertainty. The stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 4 ppb for CO2, CH4, and CO, respectively, based on differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. We conclude that the uncertainty reported for our measurements would not be significantly affected if the measurements were made without in-flight calibrations, provided ground calibrations and testing were performed regularly. Comparisons between in situ CRDS measurements and flask measurements are consistent with expected measurement uncertainties for CH4 and CO, but differences are larger than expected for CO2. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving the observed flask versus in situ CO2 differences rather than the CRDS measurements.
Long-term greenhouse gas measurements from aircraft
NASA Astrophysics Data System (ADS)
Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.
2012-10-01
In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. NOAA has installed window-replacement inlet plates on two USCG C-130 aircraft and deploys a pallet with NOAA instrumentation on each ADA flight. Flights typically last 8 h and cover a very large area, traveling from Kodiak, AK in the south up to Barrow, AK in the north, and making altitude profiles near the coast as well as in the interior. NOAA instrumentation on each flight includes: a flask sampling system, a continuous CO2/CH4/CO/H2O analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. GPS time and location from the aircraft's navigation system are also collected. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. Instruments on this aircraft are designed and deployed to be able to collect air samples and data autonomously, so that NOAA personnel visit the site only for installation at the beginning of each season. We present an assessment of the cavity ring-down spectroscopy (CRDS) CO2/CH4/CO/H2O analyzer performance operating on an aircraft over a three-year period. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction. Short and long-term stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 5 ppb for CO2, CH4, CO respectively, considering differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving biases in the comparison between flasks and in-situ CRDS measurements.
Trace Gas Analyzer (TGA) program
NASA Technical Reports Server (NTRS)
1977-01-01
The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.
NASA Astrophysics Data System (ADS)
Hayakawa, Hisao; Takada, Satoshi; Garzó, Vicente
2017-10-01
The Enskog kinetic theory for moderately dense gas-solid suspensions under simple shear flow is considered as a model to analyze the rheological properties of the system. The influence of the environmental fluid on solid particles is modeled via a viscous drag force plus a stochastic Langevin-like term. The Enskog equation is solved by means of two independent but complementary routes: (i) Grad's moment method and (ii) event-driven Langevin simulation of hard spheres. Both approaches clearly show that the flow curve (stress-strain rate relation) depends significantly on the volume fraction of the solid particles. In particular, as the density increases, there is a transition from the discontinuous shear thickening (observed in dilute gases) to the continuous shear thickening for denser systems. The comparison between theory and simulations indicates that while the theoretical predictions for the kinetic temperature agree well with simulations for densities φ ≲0.5 , the agreement for the other rheological quantities (the viscosity, the stress ratio, and the normal stress differences) is limited to more moderate densities (φ ≲0.3 ) if the inelasticity during collisions between particles is not large.
NASA Astrophysics Data System (ADS)
Kim-Hak, D.; Hoffnagle, J.; Rella, C.; Sun, M.
2016-12-01
Oxygen is a major and vital component of the Earth atmosphere representing about 21% of its composition. It is consumed or produced through biochemical processes such as combustion, respiration, and photosynthesis. Although atmospheric oxygen is not a greenhouse gas, it can be used as a top-down constraint on the carbon cycle. The variation observations of oxygen in the atmosphere are very small, in the order of the few ppm's. This presents the main technical challenge for measurement as a very high level of precision is required and only few methods including mass spectrometry, fuel cell, and paramagnetic are capable of overcoming it. Here we present new developments of a high-precision gas analyzer that utilizes the technique of Cavity Ring-Down Spectroscopy to measure oxygen concentration and oxygen isotope. Its compact and ruggedness design combined with high precision and long-term stability allows the user to deploy the instrument in the field for continuous monitoring of atmospheric oxygen level. Measurements have a 1-σ 5-minute averaging precision of 1-2 ppm for O2 over a dynamic range of 0-20%. We will present supplemental data acquired from our 10m tower measurements in Santa Clara, CA.
Dencic, Ivana; Hessel, Volker; de Croon, Mart H J M; Meuldijk, Jan; van der Doelen, Christianus W J; Koch, Kasper
2012-02-13
The miniaturization of continuous processes has been of increasing interest in the past decade, and microreaction technology and flow chemistry have moved from academic and industrial research to commercial applications. With industry taking up such innovations, this trend is also reflected in the patenting behavior of companies active in this area. This review is a continuation of the review paper on microreactor patents published by Hessel et al. and indicates major changes in patenting trends since 2006. Moreover, a different patent database search algorithm is presented, which complements the algorithm explained in the previous review. In addition, the preservation of intellectual property is analyzed for multiphase reactions and particularly solid-catalyzed gas-liquid reactions in microreactors, which play an important role in the chemical and pharmaceutical industries and are reactions that benefit largely from microprocessing. Among other results, we show that the number of patents has increased in this field, with solid-catalyst design and deposition, control of the flow pattern, and ensured stable flow as the main challenges. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hayakawa, Hisao; Takada, Satoshi; Garzó, Vicente
2017-10-01
The Enskog kinetic theory for moderately dense gas-solid suspensions under simple shear flow is considered as a model to analyze the rheological properties of the system. The influence of the environmental fluid on solid particles is modeled via a viscous drag force plus a stochastic Langevin-like term. The Enskog equation is solved by means of two independent but complementary routes: (i) Grad's moment method and (ii) event-driven Langevin simulation of hard spheres. Both approaches clearly show that the flow curve (stress-strain rate relation) depends significantly on the volume fraction of the solid particles. In particular, as the density increases, there is a transition from the discontinuous shear thickening (observed in dilute gases) to the continuous shear thickening for denser systems. The comparison between theory and simulations indicates that while the theoretical predictions for the kinetic temperature agree well with simulations for densities φ≲0.5, the agreement for the other rheological quantities (the viscosity, the stress ratio, and the normal stress differences) is limited to more moderate densities (φ≲0.3) if the inelasticity during collisions between particles is not large.
40 CFR 98.405 - Procedures for estimating missing data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids... of natural gas liquids or natural gas supplied during any period is unavailable (e.g., if a flow...
40 CFR 98.405 - Procedures for estimating missing data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids... of natural gas liquids or natural gas supplied during any period is unavailable (e.g., if a flow...
40 CFR 98.405 - Procedures for estimating missing data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids... of natural gas liquids or natural gas supplied during any period is unavailable (e.g., if a flow...
40 CFR 98.405 - Procedures for estimating missing data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids... of natural gas liquids or natural gas supplied during any period is unavailable (e.g., if a flow...
40 CFR 98.405 - Procedures for estimating missing data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids... of natural gas liquids or natural gas supplied during any period is unavailable (e.g., if a flow...
False alarm recognition in hyperspectral gas plume identification
Conger, James L [San Ramon, CA; Lawson, Janice K [Tracy, CA; Aimonetti, William D [Livermore, CA
2011-03-29
According to one embodiment, a method for analyzing hyperspectral data includes collecting first hyperspectral data of a scene using a hyperspectral imager during a no-gas period and analyzing the first hyperspectral data using one or more gas plume detection logics. The gas plume detection logic is executed using a low detection threshold, and detects each occurrence of an observed hyperspectral signature. The method also includes generating a histogram for all occurrences of each observed hyperspectral signature which is detected using the gas plume detection logic, and determining a probability of false alarm (PFA) for all occurrences of each observed hyperspectral signature based on the histogram. Possibly at some other time, the method includes collecting second hyperspectral data, and analyzing the second hyperspectral data using the one or more gas plume detection logics and the PFA to determine if any gas is present. Other systems and methods are also included.
Fiber optic coupled multipass gas minicell, design assembly thereof
Bond, Tiziana C.; Bora, Mihail; Engel, Michael A.; McCarrick, James F.; Moran, Bryan D.
2016-01-12
A method directs a gas of interest into a minicell and uses an emitting laser to produce laser emission light that is directed into the minicell and onto the gas of interest. The laser emission light is reflected within the cell to make multipasses through the gas of interest. After the multipasses through the gas of interest the laser light is analyzed to produces gas spectroscopy data. The minicell receives the gas of interest and a transmitting optic connected to the minicell that directs a beam into the minicell and onto the gas of interest. A receiving optic connected to the minicell receives the beam from the gas of interest and directs the beam to an analyzer that produces gas spectroscopy data.
Brownfield, Michael E.; Schenk, Christopher J.; Charpentier, Ronald R.; Klett, Timothy R.; Pitman, Janet K.; Tennyson, Marilyn E.; Gaswirth, Stephanie B.; Mercier, Tracey J.; Le, Phuong A.; Leathers, Heidi M.
2015-01-01
The U.S. Geological Survey estimated mean volumes of undiscovered, technically recoverable resources of 282 million barrels of conventional oil, 576 billion cubic feet of conventional gas, 1.3 billion barrels of continuous oil, and 4.6 trillion cubic feet of shale gas in the Baltic Depression Province.
NASA Astrophysics Data System (ADS)
Changnon, David; Creech, Tamara; Marsili, Nathan; Murrell, William; Saxinger, Michael
1999-06-01
During the 1997/98 El Niño event, a Northern Illinois University (NIU) faculty member and a group of undergraduate meteorology students interacted with the university's heating plant manager to determine whether climate information and forecast tools could assist him with NIU's natural gas purchase decisions each fall. Based on the El Niño-driven temperature forecasts and information developed by the faculty-directed student group, which indicated that northern Illinois would experience a warmer than average winter (December through March), the manager chose the option to ride the market on a continuous basis, buying incrementally to reduce total natural gas expenditures, rather than lock into a fixed price.To aid this annual decision process, winter El Niño-Southern Oscillation (ENSO) classifications, based on sea surface temperature (SST) data measured in the Niño-3 region, were analyzed to determine whether relationships existed between local mean winter temperature and the ENSO phenomena during the 1951-97 period. An SST ENSO model, which uses the past winter's ENSO state along with the SST trends from April through September, was developed to predict the upcoming winter's temperatures (above, near, or below average). The model predicted an 83% chance of a winter experiencing average to below-average temperatures following an El Niño winter, regardless of trend. Those winters following a non-ENSO winter with steady or increasing SST trends experienced average or above-average temperatures 79% of the time. These results supported the manager's natural gas decision, which in turn saved NIU approximately $500,000 and aided in the university's decision to hire a full-time applied meteorologist to provide advice on a continuing basis.
Comparative study of DPAL and XPAL systems and selection principal of parameters
NASA Astrophysics Data System (ADS)
Huang, Wei; Tan, Rongqing; Li, Zhiyong; Han, Gaoce; Li, Hui
2016-10-01
A theoretical model based on common pump structure is proposed to analyze the laser output characteristics of DPAL (Diode pumped alkali vapor laser) and XPAL (Exciplex pumped alkali laser) in this paper. The model predicts that an optical-to-optical efficiency approaching 80% can be achieved for continuous-wave four- and five-XPAL systems with broadband pumping which is several times of pumped linewidth for DPAL. Operation parameters including pumped intensity, temperature, cell' s length, mixed gas concentration, pumped linewidth and output mirror reflectivity are analyzed for DPAL and XPAL systems basing on the kinetic model. The result shows a better performance in Cs-Ar XPAL laser with requirements of relatively high Ar concentration, high pumped intensity and high temperature. Comparatively, for Cs-DPAL laser, lower temperature and lower pumped intensity should be acquired. In addition, the predictions of selection principal of temperature and cell's length are also presented. The conception of the equivalent "alkali areal density" is proposed in this paper. It is defined as the product of the alkali density and cell's length. The result shows that the output characteristics of DPAL (or XPAL) system with the same alkali areal density but different temperatures turn out to be equal. It is the areal density that reflects the potential of DPAL or XPAL systems directly. A more detailed analysis of similar influences of cavity parameters with the same areal density is also presented. The detailed results of continuous-wave DPAL and XPAL performances as a function of pumped laser linewidth and mixed gas pressure are presented along with an analysis of influences of output coupler.
2006-04-17
of the droplet phase are then used for validation of theoretical models of the gas-droplet plume flow. Based on experimental and numerical results...with the continuous model adequately reproduces the Arrhenius rate at high temperatures but significantly underpredicts the theoretical rate at low...continuous model and discrete model of real gas effects, and the results on the shock -wave stand-off distance were compared with the experimental data of
Performance of the future MOMA GC-ITMS instrument
NASA Astrophysics Data System (ADS)
Grand, Noel; Buch, Arnaud; Veronica, Pinnick; Szopa, Cyril; Danell, Ryan; Van Amerom, Friso H. W.; Glavin, Daniel P.; Freissinet, Caroline; Arevalo, Ricardo; Stalport, Fabien; Getty, Stephanie; Coll, Patrice; Steinninger, Harald; Brinckerhoff, William; Mahaffy, Paul; Goesmann, Fred; Raulin, F.; Goetz, Walter; MOMA Team
2016-10-01
The Mars Organic Molecule Analyzer (MOMA) experiment aboard the future ExoMars mission will be the continuation of the SAM expirement aboard the Curiosity rover, with the search for the organic composition of the Mars surface. With ExoMars the sample will be extracted as deep as 2 meters below the martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatiles compounds) of the Martian soil MOMA is composed with an UV laser desorption / ionization (LDI) and a pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS). In order to analyze refractory organic compounds and chirality samples which undergo GC-ITMS analysis may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]).To optimize and test the performance of the GC-ITMS instrument we have performed several coupling tests campaigns between the GC, providing by the French team (LISA, LATMOS, CentraleSupelec), and the MS, providing by the US team (NASA, GSFC). Last campaign has been done with the ETU models which is similar to the flight model and which include the oven and the taping station providing by the German team (MPS).The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation.
Computational analysis of a multistage axial compressor
NASA Astrophysics Data System (ADS)
Mamidoju, Chaithanya
Turbomachines are used extensively in Aerospace, Power Generation, and Oil & Gas Industries. Efficiency of these machines is often an important factor and has led to the continuous effort to improve the design to achieve better efficiency. The axial flow compressor is a major component in a gas turbine with the turbine's overall performance depending strongly on compressor performance. Traditional analysis of axial compressors involves throughflow calculations, isolated blade passage analysis, Quasi-3D blade-to-blade analysis, single-stage (rotor-stator) analysis, and multi-stage analysis involving larger design cycles. In the current study, the detailed flow through a 15 stage axial compressor is analyzed using a 3-D Navier Stokes CFD solver in a parallel computing environment. Methodology is described for steady state (frozen rotor stator) analysis of one blade passage per component. Various effects such as mesh type and density, boundary conditions, tip clearance and numerical issues such as turbulence model choice, advection model choice, and parallel processing performance are analyzed. A high sensitivity of the predictions to the above was found. Physical explanation to the flow features observed in the computational study are given. The total pressure rise verses mass flow rate was computed.
Continuous pH monitoring in a perfused bioreactor system using an optical pH sensor
NASA Technical Reports Server (NTRS)
Jeevarajan, Antony S.; Vani, Sundeep; Taylor, Thomas D.; Anderson, Melody M.
2002-01-01
Monitoring and regulating the pH of the solution in a bioprocess is one of the key steps in the success of bioreactor operation. An in-line optical pH sensor, based on the optical absorption properties of phenol red present in the medium, was developed and tested in this work for use in NASA space bioreactors based on a rotating wall-perfused vessel system supporting a baby hamster kidney (BHK-21) cell culture. The sensor was tested over three 30-day and one 124-day cell runs. The pH sensor initially was calibrated and then used during the entire cell culture interval. The pH reported by the sensor was compared to that measured by a fiber optically coupled Shimadzu spectrophotometer and a blood gas analyzer. The maximum standard error of prediction for all the four cell runs for development pH sensor against BGA was +/-0.06 pH unit and for the fiber optically coupled Shimadzu spectrophotometer against the blood gas analyzer was +/-0.05 pH unit. The pH sensor system performed well without need of recalibration for 124 days. Copyright 2002 Wiley Periodicals, Inc.
Performance profiles of major energy producers, 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-01-01
The energy industry generally and petroleum and natural gas operations in particular are frequently reacting to a variety of unsettling forces. Falling oil prices, economic upswings, currency devaluations, increasingly rigorous environmental quality standards, deregulation of electricity markets, and continued advances in exploration and production technology were among the challenges and opportunities to the industry in 1997. To analyze the extent to which these and other developments have affected energy industry financial and operating performance, strategies, and industry structure, the Energy Information Administration (EIA) maintains the Financial Reporting Systems (FRS). Through Form EIA-28, major US energy companies annually report to themore » FRS. Financial and operating information is reported by major lines of business, including oil and gas production (upstream), petroleum refining and marketing (downstream), other energy operations, and nonenergy business. Performance Profiles of Major Producers 1997 examines the interplays of energy markets, companies` strategies, and government policies (in 1997 and in historical context) that gave rise to the results given here. The report also analyzes other key aspects of energy company financial performance as seen through the multifaceted lens provided by the FRS data and complementary data for industry overall. 41 figs., 77 tabs.« less
40 CFR 1066.425 - Performing emission tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... as described in paragraph (g)(5) of this section and zero and span all batch gas analyzers as soon as practical before any batch sample analysis. You may perform this batch analyzer zero and span before the end... value after stabilizing a zero gas to the analyzer. Stabilization may include time to purge the analyzer...
NASA Astrophysics Data System (ADS)
Yuhang, X.
2017-12-01
A pumping test was carried out to explore the transfer rules of pressure drop in coal reservoir during the drainage. The experiment was divided into three stages. In the first stage, the pump displacement of 3m3/h was used to reduce the bottom hole flowing pressure and stopped until the continuous gas phase was produced; Undertaking the first stage, in the second stage, when the gas phase was continuously produced, the pump was stopped immediately. As the bottom hole flowing pressure going up without gas phase, pumping started again for a week. In the third stage ,the well pumping was carried out at the bottom hole pressure drop rate of 30Kpa/d after two months' recovery. Combined with the data of regional geology and fractured well, taking the characteristics of macroscopic coal rocks, development of pore and fracture in coal and isothermal adsorption test as the background, the features of reservoir output in each stage of the experiment were analyzed and compared, and then the transfer rules of pressure drop contained in the differences of the output was studied further. In the first and third stage of the experiment, the output of liquid phase was much larger than the space volume of coal reservoir pore and fracture in the range of 100m2. In the second stage, the output of the continuous gas phase appeared around 0.7Mpa when the continuous gas phase appears below the critical desorption pressure of 0.25Mpa during the whole experiment. The results indicate that, the transfer of pressure drop in the coal reservoir of this well is mainly horizontal, and the liquid phase produced in the reservoir mainly comes from the recharge of the reservoir at the far end of the relative high pressure area; the adsorption space of coalbed methane in the coal matrix as well as the main migration channel of fluid in the reservoir doesn't belong to the same pressure system and there exists the communication barrier between them. In addition, the increasing of the effective stress has little influence on the communication between these two systems. The definition of transfer rules in coal reservoir pressure drop, also the understanding of the correlation between the rules and characteristics of the reservoir output has great guiding significance to the establishment of pressure drop system in coalbed methane well as well as the analysis of production problems.
NASA Astrophysics Data System (ADS)
Boldyrev, A. V.; Karelin, D. L.; Muljukin, V. L.
2016-11-01
Conducted numerical research of static characteristics of the rotary gate valve at different angles of its deviation. for this purpose were set different values of pressure differential on the valve depending on which, was determined the mass flow and torque on valve axes. The mathematical model is provided by continuity equations, average on Reynolds, Navier-Stokes and energy, the equation of the perfect gas, the equations of two-layer k-e of model of turbulence. When calculating the current near walls are used Wolfstein's model and the hybrid wall functions of Reichardt for the speed and temperature. The task is solved in three-dimensional statement with use of conditions of symmetry. The structure of the current is analyzed: zones of acceleration and flow separation, whirlwinds, etc. Noted growth of hydraulic resistance of the valve with reduction of slope angle of the valve and with the increase in mass flow. Established increase of torque with reduction of the deviation angle of the valve and with increase in the mass expense.
Ceballos, Diana; Zielinska, Barbara; Fujita, Eric; Sagebiel, John
2007-03-01
Gasoline tracers were collected on solid-phase microextraction (SPME) fibers and analyzed by capillary gas chromatography with photoionization detector (GC/PID). This was part of a larger study to quantify personal exposure to motor vehicle gasoline evaporative and combustive emissions in high-end exposure microenvironments (MEs). The SPME fiber selected for this application was a 75-microm carboxen/polydimethylsiloxane. Sequential 10-min samples were collected for measurement of benzene, toluene, ethylbenzene, and ortho-, meta-, and para-xylene in different MEs in Atlanta, GA, in summer 2002 and Reno, NV, in spring 2003. Field calibrations were performed with certified gas standards in 1-L Tedlar bags for varying concentrations and exposure times. SPME detection limits were approximately 0.2 ppbv with a precision of 3-17% and accuracy of 30%. A dynamic system was designed for temperature and relative humidity calibrations, with corrections for the effects of these variables performed when necessary. SPME data compared satisfactorily with integrated canister samples, continuous PID, and field portable mass spectrometer data.
40 CFR 86.140-94 - Exhaust sample analysis.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-cycle and methanol-fueled, natural gas-fueled and liquefied petroleum gas-fueled (if non-heated FID option is used) diesel vehicle HC: (1) Zero the analyzers and obtain a stable zero reading. Recheck after...: (1) Zero HFID analyzer and obtain a stable zero reading. (2) Introduce span gas and set instrument...
40 CFR 86.140-94 - Exhaust sample analysis.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-cycle and methanol-fueled, natural gas-fueled and liquefied petroleum gas-fueled (if non-heated FID option is used) diesel vehicle HC: (1) Zero the analyzers and obtain a stable zero reading. Recheck after...: (1) Zero HFID analyzer and obtain a stable zero reading. (2) Introduce span gas and set instrument...
NASA Astrophysics Data System (ADS)
Rey Sanchez, C.; Morin, T. H.; Stefanik, K. C.; Wrighton, K. C.; Bohrer, G.
2016-12-01
Wetlands are important carbon dioxide (CO2) sinks but also the largest source of methane (CH4), a powerful greenhouse gas. Wetlands are often heterogeneous landscapes with highly diverse land covers and different paths of CH4 release and CO2 uptake. Understanding the ecosystem level greenhouse gas budget of a wetland involves understanding several carbon fluxes associated with each of the different land cover patches. We studied CO2 and CH4 fluxes from different land cover types at the Old Woman Creek (OWC) National Estuarine Research Reserve, at the Lake Erie shore in Northern Ohio. OWC is composed of four main types of land cover: open water, emergent cattail vegetation (Typha spp), floating vegetation (Nelimbo spp), and mud flats. CH4 and CO2 gas exchange was measured in each patch type using enclosed chambers monthly during the growing seasons of 2015 and 2016. During the same period of time, an eddy covariance tower was deployed in a representative section of the wetland to measure continuous site-level CO2 and CH4 fluxes. A footprint model was used to account for the relative contributions of each patch type to the flux measured by the tower. The chamber measurements were used to constrain the contributions of each patch within the flux tower footprint, and to correct the flux measurements to the whole-wetland total flux. We analyzed the spatial and temporal variability of methane and carbon dioxide and related this variation to some of the most important environmental drivers at the site. We used these data to analyze the implications of different arrangements of land cover types on the carbon balance and greenhouse-gas budget in wetlands.
Dubiel, Russell F.; Pearson, Ofori N.; Pitman, Janet K.; Pearson, Krystal M.; Kinney, Scott A.
2012-01-01
The U.S. Geological Survey (USGS) recently assessed the technically recoverable undiscovered oil and gas onshore and in State waters of the Gulf Coast region of the United States. The USGS defined three assessment units (AUs) with potential undiscovered conventional and continuous oil and gas resources in Upper Cretaceous (Cenomanian to Turonian) strata of the Eagle Ford Group and correlative rocks. The assessment is based on geologic elements of a total petroleum system, including hydrocarbon source rocks (source rock maturation, hydrocarbon generation and migration), reservoir rocks (sequence stratigraphy and petrophysical properties), and traps (formation, timing, and seals). Conventional oil and gas undiscovered resources are in updip sandstone reservoirs in the Upper Cretaceous Tuscaloosa and Woodbine Formations (or Groups) in Louisiana and Texas, respectively, whereas continuous oil and continuous gas undiscovered resources reside in the middip and downdip Upper Cretaceous Eagle Ford Shale in Texas and the Tuscaloosa marine shale in Louisiana. Conventional resources in the Tuscaloosa and Woodbine are included in the Eagle Ford Updip Sandstone Oil and Gas AU, in an area where the Eagle Ford Shale and Tuscaloosa marine shale display vitrinite reflectance (Ro) values less than 0.6%. The continuous Eagle Ford Shale Oil AU lies generally south of the conventional AU, is primarily updip of the Lower Cretaceous shelf edge, and is defined by thermal maturity values within shales of the Eagle Ford and Tuscaloosa that range from 0.6 to 1.2% Ro. Similarly, the Eagle Ford Shale Gas AU is defined downdip of the shelf edge where source rocks have Ro values greater than 1.2%. For undiscovered oil and gas resources, the USGS assessed means of: 1) 141 million barrels of oil (MMBO), 502 billion cubic feet of natural gas (BCFG), and 4 million barrels of natural gas liquids (MMBNGL) in the Eagle Ford Updip Sandstone Oil and Gas AU; 2) 853 MMBO, 1707 BCFG, and 34 MMBNGL in the Eagle Ford Shale Oil AU; and 3) 50,219 BCFG and 2009 MMBNGL in the Eagle Ford Shale Gas AU.
Continuous pressure letdown system
Sprouse, Kenneth M.; Matthews, David R.; Langowski, Terry
2010-06-08
A continuous pressure letdown system connected to a hopper decreases a pressure of a 2-phase (gas and solid) dusty gas stream flowing through the system. The system includes a discharge line for receiving the dusty gas from the hopper, a valve, a cascade nozzle assembly positioned downstream of the discharge line, a purge ring, an inert gas supply connected to the purge ring, an inert gas throttle, and a filter. The valve connects the hopper to the discharge line and controls introduction of the dusty gas stream into the discharge line. The purge ring is connected between the discharge line and the cascade nozzle assembly. The inert gas throttle controls a flow rate of an inert gas into the cascade nozzle assembly. The filter is connected downstream of the cascade nozzle assembly.
26 CFR 1.613A-2 - Exemption for certain domestic gas wells.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.613A-2 Exemption for certain... section 613 with respect to: (1) Regulated natural gas (as defined in paragraph (c) of § 1.613A-7), (2) Natural gas sold under a fixed contract (as defined in paragraph (d) of § 1.613A-7), and (3) Any...
Lorenson, T.D.; Collett, Timothy S.
2011-01-01
Gas hydrate deposits are common on the North Slope of Alaska around Prudhoe Bay; however, the extent of these deposits is unknown outside of this area. As part of a U.S. Geological Survey (USGS) and Bureau of Land Management gas hydrate research collaboration, well-cutting and mud-gas samples have been collected and analyzed from mainly industry-drilled wells on the North Slope for the purpose of prospecting for gas hydrate deposits. On the Alaska North Slope, gas hydrates are now recognized as an element within a petroleum systems approach or "total petroleum system." Since 1979, 35 wells have been sampled from as far west as Wainwright to Prudhoe Bay in the east. Regionally, the USGS has assessed the gas hydrate resources of the North Slope and determined that there is about 85.4 trillion cubic feet of technically recoverable hydrate-bound gas within three assessment units. The assessment units are defined mainly by three separate stratigraphic sections and constrained by the physical temperatures and pressures where gas hydrate can form. Geochemical studies of known gas hydrate occurrences on the North Slope have shown a link between gas hydrate and more deeply buried conventional oil and gas deposits. The link is established when hydrocarbon gases migrate from depth and charge the reservoir rock within the gas hydrate stability zone. It is likely gases migrated into conventional traps as free gas and were later converted to gas hydrate in response to climate cooling concurrent with permafrost formation. Results from this study indicate that some thermogenic gas is present in 31 of the wells, with limited evidence of thermogenic gas in four other wells and only one well with no thermogenic gas. Gas hydrate is known to occur in one of the sampled wells, likely present in 22 others on the basis of gas geochemistry, and inferred by equivocal gas geochemistry in 11 wells, and one well was without gas hydrate. Gas migration routes are common in the North Slope and include faults and widespread, continuous shallowly dipping permeable sand sections that are potentially in communication with deeper oil and gas sources. The application of the petroleum system model with the geochemical evidence suggests that gas hydrate deposits may be widespread across the North Slope of Alaska.
Marchewka, W.; Mohamed, K.; Addis, J.; Karnack, F.
2015-01-01
A tube bundle system (TBS) is a mechanical system for continuously drawing gas samples through tubes from multiple monitoring points located in an underground coal mine. The gas samples are drawn via vacuum pump to the surface and are typically analyzed for oxygen, methane, carbon dioxide and carbon monoxide. Results of the gas analyses are displayed and recorded for further analysis. Trends in the composition of the mine atmosphere, such as increasing methane or carbon monoxide concentration, can be detected early, permitting rapid intervention that prevents problems, such as a potentially explosive atmosphere behind seals, fire or spontaneous combustion. TBS is a well-developed technology and has been used in coal mines around the world for more than 50 years. Most longwall coal mines in Australia deploy a TBS, usually with 30 to 40 monitoring points as part of their atmospheric monitoring. The primary uses of a TBS are detecting spontaneous combustion and maintaining sealed areas inert. The TBS might also provide mine atmosphere gas composition data after a catastrophe occurs in an underground mine, if the sampling tubes are not damaged. TBSs are not an alternative to statutory gas and ventilation airflow monitoring by electronic sensors or people; rather, they are an option to consider in an overall mine atmosphere monitoring strategy. This paper describes the hardware, software and operation of a TBS and presents one example of typical data from a longwall coal mine PMID:26306052
Tube bundle system: for monitoring of coal mine atmosphere.
Zipf, R Karl; Marchewka, W; Mohamed, K; Addis, J; Karnack, F
2013-05-01
A tube bundle system (TBS) is a mechanical system for continuously drawing gas samples through tubes from multiple monitoring points located in an underground coal mine. The gas samples are drawn via vacuum pump to the surface and are typically analyzed for oxygen, methane, carbon dioxide and carbon monoxide. Results of the gas analyses are displayed and recorded for further analysis. Trends in the composition of the mine atmosphere, such as increasing methane or carbon monoxide concentration, can be detected early, permitting rapid intervention that prevents problems, such as a potentially explosive atmosphere behind seals, fire or spontaneous combustion. TBS is a well-developed technology and has been used in coal mines around the world for more than 50 years. Most longwall coal mines in Australia deploy a TBS, usually with 30 to 40 monitoring points as part of their atmospheric monitoring. The primary uses of a TBS are detecting spontaneous combustion and maintaining sealed areas inert. The TBS might also provide mine atmosphere gas composition data after a catastrophe occurs in an underground mine, if the sampling tubes are not damaged. TBSs are not an alternative to statutory gas and ventilation airflow monitoring by electronic sensors or people; rather, they are an option to consider in an overall mine atmosphere monitoring strategy. This paper describes the hardware, software and operation of a TBS and presents one example of typical data from a longwall coal mine.
The Effect of Thermal Convection on Earth-Atmosphere CO2 Gas Exchange in Aggregated Soil
NASA Astrophysics Data System (ADS)
Ganot, Y.; Weisbrod, N.; Dragila, M. I.
2011-12-01
Gas transport in soils and surface-atmosphere gas exchange are important processes that affect different aspects of soil science such as soil aeration, nutrient bio-availability, sorption kinetics, soil and groundwater pollution and soil remediation. Diffusion and convection are the two main mechanisms that affect gas transport, fate and emissions in the soils and in the upper vadose zone. In this work we studied CO2 soil-atmosphere gas exchange under both day-time and night-time conditions, focusing on the impact of thermal convection (TCV) during the night. Experiments were performed in a climate-controlled laboratory. One meter long columns were packed with matrix of different grain size (sand, gravel and soil aggregates). Air with 2000 ppm CO2 was injected into the bottom of the columns and CO2 concentration within the columns was continuously monitored by an Infra Red Gas Analyzer. Two scenarios were compared for each soil: (1) isothermal conditions, representing day time conditions; and (2) thermal gradient conditions, i.e., atmosphere colder than the soil, representing night time conditions. Our results show that under isothermal conditions, diffusion is the major mechanism for surface-atmosphere gas exchange for all grain sizes; while under night time conditions the prevailing mechanism is dependent on the air permeability of the matrix: for sand and gravel it is diffusion, and for soil aggregates it is TCV. Calculated CO2 flux for the soil aggregates column shows that the TCV flux was three orders of magnitude higher than the diffusive flux.
40 CFR 98.400 - Definition of the source category.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.400 Definition of the source category. This supplier category consists of natural gas liquids fractionators and local natural gas distribution companies. (a) Natural gas liquids fractionators are installations that...
40 CFR 98.400 - Definition of the source category.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.400 Definition of the source category. This supplier category consists of natural gas liquids fractionators and local natural gas distribution companies. (a) Natural gas liquids fractionators are installations that...
40 CFR 98.400 - Definition of the source category.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.400 Definition of the source category. This supplier category consists of natural gas liquids fractionators and local natural gas distribution companies. (a) Natural gas liquids fractionators are installations that...
40 CFR 98.400 - Definition of the source category.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.400 Definition of the source category. This supplier category consists of natural gas liquids fractionators and local natural gas distribution companies. (a) Natural gas liquids fractionators are installations that...
40 CFR 98.400 - Definition of the source category.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.400 Definition of the source category. This supplier category consists of natural gas liquids fractionators and local natural gas distribution companies. (a) Natural gas liquids fractionators are installations that...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-22
... a continued high level of reliability of interstate natural gas pipelines and that this will, in turn, ensure a continued high level of reliability of the electric transmission grid.\\40\\ Consumers...
49 CFR 193.2507 - Monitoring operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... watching or listening from an attended control center for warning alarms, such as gas, temperature...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
26 CFR 1.611-2 - Rules applicable to mines, oil and gas wells, and other natural deposits.
Code of Federal Regulations, 2011 CFR
2011-04-01
... other natural deposits. 1.611-2 Section 1.611-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.611-2 Rules applicable to mines, oil and gas wells, and other natural deposits. (a) Computation of cost...
Risk analysis of urban gas pipeline network based on improved bow-tie model
NASA Astrophysics Data System (ADS)
Hao, M. J.; You, Q. J.; Yue, Z.
2017-11-01
Gas pipeline network is a major hazard source in urban areas. In the event of an accident, there could be grave consequences. In order to understand more clearly the causes and consequences of gas pipeline network accidents, and to develop prevention and mitigation measures, the author puts forward the application of improved bow-tie model to analyze risks of urban gas pipeline network. The improved bow-tie model analyzes accident causes from four aspects: human, materials, environment and management; it also analyzes the consequences from four aspects: casualty, property loss, environment and society. Then it quantifies the causes and consequences. Risk identification, risk analysis, risk assessment, risk control, and risk management will be clearly shown in the model figures. Then it can suggest prevention and mitigation measures accordingly to help reduce accident rate of gas pipeline network. The results show that the whole process of an accident can be visually investigated using the bow-tie model. It can also provide reasons for and predict consequences of an unfortunate event. It is of great significance in order to analyze leakage failure of gas pipeline network.
Study, optimization, and design of a laser heat engine
NASA Technical Reports Server (NTRS)
1978-01-01
Laser heat engine concepts, proposed for satellite applications, were analyzed to determine which engine concepts best meet the requirements of high efficiency (50 percent or better) continuous operation in space. The best laser heat engine for a near-term experimental demonstration, selected on the basis of high overall operating efficiency, high power-to-weight characteristics, and availability of the required technology, is an Otto/Diesel cycle piston engine using a diamond window to admit CO2 laser radiation. The technology with the greatest promise of scaling to megawatt power levels in the long term is the energy exchanger/gas turbine combination.
Preliminary analysis of a downsized advanced gas-turbine engine in a subcompact car
NASA Technical Reports Server (NTRS)
Klann, J. L.; Johnsen, R. L.
1982-01-01
Relative fuel economy advantages exist for a ceramic turbine engine when it is downsized for a small car were investigated. A 75 kW (100 hp) single shaft engine under development was analytically downsized to 37 kW (50 hp) and analyzed with a metal belt continuously variable transmission in a synthesized car. With gasoline, a 25% advantage was calculated over that of a current spark ignition engine, scaled to the same power, using the same transmission and car. With diesel fuel, a 21% advantage was calculated over that of a similar diesel engine vehicle.
Feedback between neutral winds and auroral arc electrodynamics
NASA Technical Reports Server (NTRS)
Lyons, L. R.; Walterscheid, R. L.
1986-01-01
The feedback between neutral atmospheric winds and the electrodynamics of a stable, discrete auroral arc is analyzed. The ionospheric current continuity equation and the equation for neutral gas acceleration by ion drag are solved simultaneously, as a function of time. The results show that, in general, the electric field in the ionosphere adjusts to neutral wind acceleration so as to keep auroral field-aligned currents and electron acceleration approximately independent of time. It is thus concluded that the neutral winds that develop as a result of the electrodynamical forcing associated with an arc do not significantly affect the intensity of the arc.
Analysis of volatile organic compounds. [trace amounts of organic volatiles in gas samples
NASA Technical Reports Server (NTRS)
Zlatkis, A. (Inventor)
1977-01-01
An apparatus and method are described for reproducibly analyzing trace amounts of a large number of organic volatiles existing in a gas sample. Direct injection of the trapped volatiles into a cryogenic percolum provides a sharply defined plug. Applications of the method include: (1) analyzing the headspace gas of body fluids and comparing a profile of the organic volatiles with standard profiles for the detection and monitoring of disease; (2) analyzing the headspace gas of foods and beverages and comparing the profile with standard profiles to monitor and control flavor and aroma; and (3) analyses for determining the organic pollutants in air or water samples.
Real-time airborne particle analyzer
Reilly, Peter T.A.
2012-10-16
An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.
49 CFR 193.2059 - Flammable vapor-gas dispersion protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Flammable vapor-gas dispersion protection. 193.2059 Section 193.2059 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE...
49 CFR 192.939 - What are the required reassessment intervals?
Code of Federal Regulations, 2010 CFR
2010-10-01
....939 Section 192.939 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas...
49 CFR 192.947 - What records must an operator keep?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 192.947 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline...
49 CFR 193.2001 - Scope of part.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... LNG facilities used in the transportation of gas by pipeline that is subject to the pipeline safety...
49 CFR 193.2503 - Operating procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... pressure so that the resultant gas is within limits established for the vaporizer and the downstream piping...
49 CFR 192.949 - How does an operator notify PHMSA?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 192.949 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity...
49 CFR 192.1011 - What records must an operator keep?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 192.1011 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline...
Assessment of undiscovered oil and gas resources in the Ventura Basin Province, California, 2016
Tennyson, Marilyn E.; Schenk, Christopher J.; Pitman, Janet K.; Lillis, Paul G.; Klett, Timothy R.; Brownfield, Michael E.; Finn, Thomas M.; Gaswirth, Stephanie B.; Hawkins, Sarah J.; Marra, Kristen R.; Mercier, Tracey J.; Le, Phuong A.; Leathers-Miller, Heidi M.
2017-10-02
The U.S. Geological Survey (USGS) completed a geology-based assessment of undiscovered, technically recoverable conventional and continuous oil and gas resources in the part of the Ventura Basin Province that lies onshore or within State waters (within 3 miles of the shoreline) of California (fig. 1). Conventional oil and gas resources are those that have migrated upward into structural or stratigraphic traps from deep zones where the oil and gas is generated; water is present below the oil or gas. Continuous accumulations, in contrast, are those in which oil or gas is pervasively present in essentially all wells that penetrate them, that may not be structurally or stratigraphically trapped, and that typically lack oil-water or gas-water contacts. They are commonly produced with well-stimulation technology, such as hydraulic fracturing, referred to as “unconventional.” The same stimulation technology, however, is also used in many conventionally trapped accumulations. We estimated both the likely range of oil and gas volumes remaining to be discovered in accumulations similar to existing conventional oil and gas fields in the Ventura Basin Province (previously assessed by Keller [1995] as 1,060 million barrels of oil [MMBO], 1,900 billion cubic feet of gas [BCFG], and 60 million barrels of natural gas liquids [MMBNGL]), and the potential for oil and gas that might be present in a continuous accumulation at extreme depth in the floor of the basin.
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403...). Fuel = Total annual volume of product “h” supplied (volume per year, in Mscf for natural gas and bbl... procedures below. (1) For natural gas that is received for redelivery to downstream gas transmission...
Farmery, A D; Hahn, C E
2000-08-01
Tidal ventilation gas-exchange models in respiratory physiology and medicine not only require solution of mass balance equations breath-by-breath but also may require within-breath measurements, which are instantaneous functions of time. This demands a degree of temporal resolution and fidelity of integration of gas flow and concentration signals that cannot be provided by most clinical gas analyzers because of their slow response times. We have characterized the step responses of the Datex Ultima (Datex Instrumentation, Helsinki, Finland) gas analyzer to oxygen, carbon dioxide, and nitrous oxide in terms of a Gompertz four-parameter sigmoidal function. By inversion of this function, we were able to reduce the rise times for all these gases almost fivefold, and, by its application to real on-line respiratory gas signals, it is possible to achieve a performance comparable to the fastest mass spectrometers. With the use of this technique, measurements required for non-steady-state and tidal gas-exchange models can be made easily and reliably in the clinical setting.
Continuous versus Arrested Spreading of Biofilms at Solid-Gas Interfaces: The Role of Surface Forces
NASA Astrophysics Data System (ADS)
Trinschek, Sarah; John, Karin; Lecuyer, Sigolène; Thiele, Uwe
2017-08-01
We introduce and analyze a model for osmotically spreading bacterial colonies at solid-air interfaces that includes wetting phenomena, i.e., surface forces. The model is based on a hydrodynamic description for liquid suspensions which is supplemented by bioactive processes. We show that surface forces determine whether a biofilm can expand laterally over a substrate and provide experimental evidence for the existence of a transition between continuous and arrested spreading for Bacillus subtilis biofilms. In the case of arrested spreading, the lateral expansion of the biofilm is confined, albeit the colony is biologically active. However, a small reduction in the surface tension of the biofilm is sufficient to induce spreading. The incorporation of surface forces into our hydrodynamic model allows us to capture this transition in biofilm spreading behavior.
Thermoelectric Devices Advance Thermal Management
NASA Technical Reports Server (NTRS)
2007-01-01
Thermoelectric (TE) devices heat, cool, and generate electricity when a temperature differential is provided between the two module faces. In cooperation with NASA, Chico, California-based United States Thermoelectric Consortium Inc. (USTC) built a gas emissions analyzer (GEA) for combustion research. The GEA precipitated hydrocarbon particles, preventing contamination that would hinder precise rocket fuel analysis. The USTC research and design team uses patent-pending dimple, pin-fin, microchannel and microjet structures to develop and design heat dissipation devices on the mini-scale level, which not only guarantee high performance of products, but also scale device size from 1 centimeter to 10 centimeters. USTC continues to integrate the benefits of TE devices in its current line of thermal management solutions and has found the accessibility of NASA technical research to be a valuable, sustainable resource that has continued to positively influence its product design and manufacturing
A critical evaluation of automated blood gas measurements in comparative respiratory physiology.
Malte, Christian Lind; Jakobsen, Sashia Lindhøj; Wang, Tobias
2014-12-01
Precise measurements of blood gases and pH are of pivotal importance to respiratory physiology. However, the traditional electrodes that could be calibrated and maintained at the same temperature as the experimental animal are increasingly being replaced by new automated blood gas analyzers. These are typically designed for clinical use and automatically heat the blood sample to 37°C for measurements. While most blood gas analyzers allow for temperature corrections of the measurements, the underlying algorithms are based on temperature-effects for human blood, and any discrepancies in the temperature dependency between the blood sample from a given species and human samples will bias measurements. In this study we review the effects of temperature on blood gases and pH and evaluate the performance of an automated blood gas analyzer (GEM Premier 3500). Whole blood obtained from pythons and freshwater turtles was equilibrated in rotating Eschweiler tonometers to a variety of known P(O2)'s and P(CO2)'s in gas mixtures prepared by Wösthoff gas mixing pumps and blood samples were measured immediately on the GEM Premier 3500. The pH measurements were compared to measurements using a Radiometer BMS glass capillary pH electrode kept and calibrated at the experimental temperature. We show that while the blood gas analyzer provides reliable temperature-corrections for P(CO2) and pH, P(O2) measurements were substantially biased. This was in agreement with the theoretical considerations and emphasizes the need for critical calibrations/corrections when using automated blood gas analyzers. Copyright © 2014 Elsevier Inc. All rights reserved.
26 CFR 1.613A-3 - Exemption for independent producers and royalty owners.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.613A-3 Exemption for... domestic natural gas (as defined in paragraphs (a) and (b) of § 1.613A-7) as does not exceed the taxpayer's depletable natural gas quantity (as defined in paragraph (i) of § 1.613A-7), and the applicable percentage...
Assessment of continuous oil and gas resources of the Cooper Basin, Australia, 2016
Schenk, Christopher J.; Tennyson, Marilyn E.; Mercier, Tracey J.; Klett, Timothy R.; Finn, Thomas M.; Le, Phuong A.; Brownfield, Michael E.; Gaswirth, Stephanie B.; Marra, Kristen R.; Hawkins, Sarah J.; Leathers-Miller, Heidi M.
2016-07-15
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean continuous resources of 482 million barrels of oil and 29.8 trillion cubic feet of gas in the Cooper Basin of Australia.
Assessment of continuous gas resources in the Khorat Plateau Province, Thailand and Laos, 2016
Schenk, Christopher J.; Klett, Timothy R.; Mercier, Tracey J.; Finn, Thomas M.; Tennyson, Marilyn E.; Gaswirth, Stephanie B.; Marra, Kristen R.; Le, Phuong A.; Drake, Ronald M.
2017-05-25
Using a geology-based assessment methodology, the U.S. Geological Survey assessed mean undiscovered, technically recoverable resources of 2.3 trillion cubic feet of continuous gas in the Khorat Plateau Province of Thailand and Laos.
29 CFR 1926.1086 - Mixed-gas diving.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Diving Specific Operations Procedures § 1926.1086 Mixed-gas diving. Note: The requirements applicable to construction work under this section are...
49 CFR 192.919 - What must be in the baseline assessment plan?
Code of Federal Regulations, 2010 CFR
2010-10-01
....919 Section 192.919 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas...
Higley, D.K.; Gaswirth, S.B.; Abbott, M.M.; Charpentier, R.R.; Cook, T.A.; Ellis, G.S.; Gianoutsos, N.J.; Hatch, J.R.; Klett, T.R.; Nelson, Philip H.; Pawlewicz, M.J.; Pearson, O.N.; Pollastro, R.M.; Schenk, C.J.
2011-01-01
The U.S. Geological Survey, using a geoscience-based assessment methodology, estimated mean technically-recoverable undiscovered continuous and conventional resources that total 495 million barrels of oil, 27.5 trillion cubic feet of natural gas, and 410 million barrels of natural gas liquids in the Anadarko Basin Province; this assessment includes the Las Animas arch area of southeastern Colorado. The province is at a mature stage of exploration and development for conventional resources. Mean undiscovered continuous resources are estimated at 79 percent of oil, 90 percent of natural gas, and 81 percent of natural gas liquids in the province.
Chemical recognition of gases and gas mixtures with terahertz waves.
Jacobsen, R H; Mittleman, D M; Nuss, M C
1996-12-15
A time-domain chemical-recognition system for classifying gases and analyzing gas mixtures is presented. We analyze the free induction decay exhibited by gases excited by far-infrared (terahertz) pulses in the time domain, using digital signal-processing techniques. A simple geometric picture is used for the classif ication of the waveforms measured for unknown gas species. We demonstrate how the recognition system can be used to determine the partial pressures of an ammonia-water gas mixture.
Chemical recognition of gases and gas mixtures with terahertz waves
NASA Astrophysics Data System (ADS)
Jacobsen, R. H.; Mittleman, D. M.; Nuss, M. C.
1996-12-01
A time-domain chemical-recognition system for classifying gases and analyzing gas mixtures is presented. We analyze the free induction decay exhibited by gases excited by far-infrared (terahertz) pulses in the time domain, using digital signal-processing techniques. A simple geometric picture is used for the classification of the waveforms measured for unknown gas species. We demonstrate how the recognition system can be used to determine the partial pressures of an ammonia-water gas mixture.
Electron-less negative ion extraction from ion-ion plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rafalskyi, Dmytro; Aanesland, Ane
2015-03-09
This paper presents experimental results showing that continuous negative ion extraction, without co-extracted electrons, is possible from highly electronegative SF{sub 6} ion-ion plasma at low gas pressure (1 mTorr). The ratio between the negative ion and electron densities is more than 3000 in the vicinity of the two-grid extraction and acceleration system. The measurements are conducted by both magnetized and non-magnetized energy analyzers attached to the external grid. With these two analyzers, we show that the extracted negative ion flux is almost electron-free and has the same magnitude as the positive ion flux extracted and accelerated when the grids aremore » biased oppositely. The results presented here can be used for validation of numerical and analytical models of ion extraction from ion-ion plasma.« less
Biopurification of industrial waste gas from rubber regeneration.
Sun, Peishi; Yang, Xianwan; Huang, Ruohua; Bin, Huang; Zheng, Sunsheng; Wei, Zaishan; Xu, Xiaoyi; Lu, Jilai; Sun, Xing; Chen, Liuxin
2004-12-01
By using the biopurifying technology, the organic waste gas in low concentrations emitted from the rubber-regeneration process was purified in this research. The result of the 100-day continuous running test of the industrial test device indicated that the purification efficiency of toluene in the rubber-regeneration waste gas could be maintained at about 90% for a long period of time and the treated waste gas could meet the China National Emission Standard. The cost of waste gas biotreatment was about 0.12-0.14% of rubber-regeneration production value of the factory. The biopurifying technology of waste gas displayed its excellent technical advancement and economic rationale. The following industrialized device was run continuously and passed the examination and acceptance by the local EPA.
Delay time correction of the gas analyzer in the calculation of anatomical dead space of the lung.
Okubo, T; Shibata, H; Takishima, T
1983-07-01
By means of a mathematical model, we have studied a way to correct the delay time of the gas analyzer in order to calculate the anatomical dead space using Fowler's graphical method. The mathematical model was constructed of ten tubes of equal diameter but unequal length, so that the amount of dead space varied from tube to tube; the tubes were emptied sequentially. The gas analyzer responds with a time lag from the input of the gas signal to the beginning of the response, followed by an exponential response output. The single breath expired volume-concentration relationship was examined with three types of expired flow patterns of which were constant, exponential and sinusoidal. The results indicate that the time correction by the lag time plus time constant of the exponential response of the gas analyzer gives an accurate estimation of anatomical dead space. Time correction less inclusive than this, e.g. lag time only or lag time plus 50% response time, gives an overestimation, and a correction larger than this results in underestimation. The magnitude of error is dependent on the flow pattern and flow rate. The time correction in this study is only for the calculation of dead space, as the corrected volume-concentration curves does not coincide with the true curve. Such correction of the output of the gas analyzer is extremely important when one needs to compare the dead spaces of different gas species at a rather faster flow rate.
40 CFR 98.364 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... by Gas Chromatography (incorporated by reference see § 98.7). All gas composition monitors shall be...-90 (Reapproved 2006) Standard Practice for Analysis of Reformed Gas by Gas Chromatography... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Manure Management § 98.364 Monitoring and QA/QC requirements...
40 CFR 98.364 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... by Gas Chromatography (incorporated by reference see § 98.7). All gas composition monitors shall be...-90 (Reapproved 2006) Standard Practice for Analysis of Reformed Gas by Gas Chromatography... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Manure Management § 98.364 Monitoring and QA/QC requirements...
49 CFR 192.620 - Alternative maximum allowable operating pressure for certain steel pipelines.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY...) At points where gas with potentially deleterious contaminants enters the pipeline, use filter...
Assessment of undiscovered continuous oil and gas resources in the Hanoi Trough, Vietnam, 2017
Schenk, Christopher J.; Tennyson, Marilyn E.; Mercier, Tracey J.; Woodall, Cheryl A.; Le, Phuong A.; Klett, Timothy R.; Finn, Thomas M.; Leathers-Miller, Heidi M.; Gaswirth, Stephanie B.; Marra, Kristen R.
2018-02-13
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 52 million barrels of oil and 591 billion cubic feet of gas in the Hanoi Trough of Vietnam.
NASA Astrophysics Data System (ADS)
Wan, Z.; Xu, X.; Wang, X.
2016-12-01
The mud diapir/volcano is an important indicator for gas hydrate exploration, which develops widely in continental slopes. There are many mud diapirs/volcanoes developed in northern South China Sea continental slope. Guangzhou Marine Geological Survey (GMGS) of the Chinese Ministry of Land and Resources targeted mud diapirs/volcanoes and deployed gas hydrate drilling in the Shenhu area. An obvious mud diapir developed below borehole number SH5, and bottom-simulating reflection (BSR) was also detected, but no gas hydrates were found at this borehole. We analyzed the thermal structure of mud diapirs and their relationship to the occurrence of gas hydrates. The in situ temperature at the seafloor is approximately 2.2 2.5oC in the study area. Seafloor heat flow values of SH5 is 71.4mW/m2. Temperature increases rapidly to 17oC from 40 m to 100 m and stays in the range of 17 to 19oC below 100 m. And the thermal conductivity value of SH5 is approximately 1.0 W/m·k from top to bottom. The evolution of the mud diapir/volcanoes can be divided into three stages within a continuous geological process controlling the gas hydrate reservoir. During the late stage, liquid from the mud diapir/volcanoes begins to invade the gas hydrate stability zone . Because of the high unit heat capacity of liquid, the whole temperature field of the surrounding layers increases significantly when the mud diapir/volcanoes pierces upwards. This high heat flow leads to decomposition of the gas hydrates. Therefore, the reason of SH5 did not find gas hydrates may be that the mud diapir had pierced through during the late stage, leading to gas hydrate decomposition, even though there is an obvious BSR. This work was supported by Science and Technology Program of Guangzhou (No. 201607010214) and National Nature Science Foundation of China (No. 91128203,41102077).
26 CFR 1.612-4 - Charges to capital and to expense in case of oil and gas wells.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 7 2011-04-01 2009-04-01 true Charges to capital and to expense in case of oil and gas wells. 1.612-4 Section 1.612-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.612-4 Charges to...
An on-line acoustic fluorocarbon coolant mixture analyzer for the ATLAS silicon tracker
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bates, R.; Battistin, M.; Berry, S.
2011-07-01
The ATLAS silicon tracker community foresees an upgrade from the present octafluoro-propane (C{sub 3}F{sub 8}) evaporative cooling fluid - to a composite fluid with a probable 10-20% admixture of hexafluoro-ethane (C{sub 2}F{sub 6}). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C{sub 3}F{sub 8}/C{sub 2}F{sub 6} mixturemore » ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound 'chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C{sub 3}F{sub 8}/C{sub 2}F{sub 6} flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semiconductor manufacture and anesthetic gas mixtures. (authors)« less
An On-Line Acoustic Fluorocarbon Coolant Mixture Analyzer for the ATLAS Silicon Tracker
NASA Astrophysics Data System (ADS)
Bates, R.; Battistin, M.; Berry, S.; Bitadze, A.; Bonneau, P.; Bousson, N.; Boyd, G.; Botelho-Direito, J.; DiGirolamo, B.; Doubek, M.; Egorov, K.; Godlewski, J.; Hallewell, G.; Katunin, S.; Mathieu, M.; McMahon, S.; Nagai, K.; Perez-Rodriguez, E.; Rozanov, A.; Vacek, V.; Vitek, M.
2012-10-01
The ATLAS silicon tracker community foresees an upgrade from the present octafluoropropane (C3F8) evaporative cooling fluid to a composite fluid with a probable 10-20% admixture of hexafluoroethane (C2F6). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C3F8/C2F6 mixture ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound `chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C3F8/C2F6 flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semi-conductor manufacture and anesthetic gas mixtures.
Luukkonen, Antti A M; Lehto, Tiina M; Hedberg, Pirjo S M; Vaskivuo, Tommy E
2016-04-01
Intensive care units, operating rooms, emergency departments, and neonatology units need rapid measurements of blood gases, electrolytes, and metabolites. These analyses can be performed in a central laboratory or at the clinic with traditional or compact cassette-type blood gas analyzers such as the epoc blood gas testing system for analyzing whole blood samples at the bedside. In this study, the performance and interchangeability of a hand-held epoc blood gas analyzer was evaluated. The analytical performance of the epoc analyzer was evaluated by determining within-and between-run precisions. The accuracy of the epoc analyzer was assessed by comparing patient results from the device with those obtained with the Siemens Rapidlab 1265 and Rapidpoint RP500 and Siemens Dimension Vista and Sysmex XE-2100 analyzers. The following parameters were measured: pH, pCO2, pO2, Hb (calc), Na+, K+, iCa2+, glucose, and lactate. The CV% of the epoc's between-day imprecision for the various parameters varied from 0.4 to 8.6. The within-run imprecision CV% varied from 0.6 to 5.2. The squared regression coefficient (R2) between the epoc and RL1265 varied from 0.94 to 0.99, with the exception of Na+ and Ca2+ (R2≥0.82). The correlation (R2) of Na+ and K+ between epoc and Dimension Vista was 0.73 and 0.89, respectively. The correlation (R2) of Hb between the epoc and the XE-2100 analyzer was 0.94. With most of the measured blood gas parameters, the epoc analyzer correlated well with reference techniques. The epoc analyzer is suitable for rapid measurement of the blood gases, the electrolytes, and the metabolites in the ICU.
GAS-FOVEAL CONTACT: A New Approach to Evaluating Positioning Regimens in Macular Hole Surgery.
Alberti, Mark; la Cour, Morten
2018-05-01
To compare gas-foveal contact in face-down positioning (FDP) and nonsupine positioning (NSP), to analyze causes of gas-foveal separation and to determine how gas-foveal contact affects clinical outcome after idiopathic macular hole repair. Single center, randomized controlled study. Participants with an idiopathic macular hole were allocated to either FDP or NSP. Primary outcome was gas-foveal contact, calculated by analyzing positioning in relation to intraocular gas fill. Positioning was measured with an electronic device recording positioning for 72 hours postoperatively. Positioning data were available for 33/35 in the FDP group and 35/37 in the NSP group, thus results are based on 68 analyzed participants. Median gas-foveal contact was 99.82% (range 73.6-100.0) in the FDP group and 99.57% (range 85.3-100.0) in the NSP group (P = 0.22). In a statistical model, gas fill had a significant relation to gas-foveal contact (P < 0.0001), whereas whether the surgeon prescribed FDP or NSP was not significant (P = 0.20). Of clinical relevance, gas-foveal contact seemed to influence idiopathic macular hole closure (P = 0.02). We found no significant difference in gas-foveal contact between the positioning groups. The role of positioning after idiopathic macular hole surgery seems to be better characterized from examining both patient positioning and gas fill objectively. We propose gas-foveal contact as a new outcome for evaluating positioning regimens.
Discovery sequence and the nature of low permeability gas accumulations
Attanasi, E.D.
2005-01-01
There is an ongoing discussion regarding the geologic nature of accumulations that host gas in low-permeability sandstone environments. This note examines the discovery sequence of the accumulations in low permeability sandstone plays that were classified as continuous-type by the U.S. Geological Survey for the 1995 National Oil and Gas Assessment. It compares the statistical character of historical discovery sequences of accumulations associated with continuous-type sandstone gas plays to those of conventional plays. The seven sandstone plays with sufficient data exhibit declining size with sequence order, on average, and in three of the seven the trend is statistically significant. Simulation experiments show that both a skewed endowment size distribution and a discovery process that mimics sampling proportional to size are necessary to generate a discovery sequence that consistently produces a statistically significant negative size order relationship. The empirical findings suggest that discovery sequence could be used to constrain assessed gas in untested areas. The plays examined represent 134 of the 265 trillion cubic feet of recoverable gas assessed in undeveloped areas of continuous-type gas plays in low permeability sandstone environments reported in the 1995 National Assessment. ?? 2005 International Association for Mathematical Geology.
1991-07-01
predicted by equation using actual chart response obtained from each calibration gas response. (Concentration of cal. gas,l Calibration error, % span • ppm...Analyzer predicted by cali- Col. gas Chart divisions equation* bration Cylinder conc., error,** Drift,***INo. ppm or % Pretest Posttest Pretest Posttest...2m ~J * Correlation coef. * qgq’jq **Analyzer ca.error, % spn (Cal. gas conc. conc. predicted ) x 1003 cal spanSpan value Acceptable limit x ɚ% of
NASA Astrophysics Data System (ADS)
Gardner, A.; Baer, D. S.; Owano, T. G.; Provencal, R. A.; Gupta, M.; Parsotam, V.; Graves, P.; Goldstein, A.; Guha, A.
2010-12-01
Development and Deployment of Mobile Emissions Laboratory for Continuous Long-Term Unattended Measurements of Greenhouse Gases, Fluxes, Isotopes and Pollutants A. Gardner(1), D. Baer (1), T. Owano (1), R. Provencal (1), V. Parsotam (1), P. Graves (1), M. Gupta (1), Allen Goldstein (2), Abhinav Guha (2) (1) Los Gatos Research, 67 East Evelyn Avenue, Suite 3, Mountain View, CA 94041-1529 (2) Department of Environmental Science, Policy, and Management, University of California at Berkeley Quantifying the Urban Fossil Fuel Plume: Convergence of top-down and bottom-up approaches (Session A54). We report on the design, development and deployment of a novel Mobile Emissions Laboratory, consisting of innovative laser-based gas analyzers, for rapid measurements of multiple greenhouse gases and pollutants. Designed for real-time mobile and stationery emissions monitoring, the Mobile Emissions Laboratory was deployed at several locations during 2010, including CalNEX 2010, Caldecott Tunnel (Oakland, CA), and Altamont Landfill (Livermore, CA), to record real-time continuous measurements of isotopic CO2 (δ13C, CO2), methane (CH4), acetylene (C2H2), nitrous oxide (N2O), carbon monoxide (CO), and isotopic water vapor (H2O; δ18O, δ2H). The commercial gas analyzers are based on novel cavity-enhanced laser absorption spectroscopy. The portable analyzers provide measurements in real time, require about 150 watts (each) of power and do not need liquid nitrogen to operate. These instruments have been applied in the field for applications that require high data rates (for eddy correlation flux), wide dynamic range (e.g., for chamber flux and other applications with concentrations that can be 10-1000 times higher than typical ambient levels) and highest accuracy (atmospheric monitoring stations). The Mobile Emissions Laboratory, which contains onboard batteries for long-term unattended measurements without access to mains power, can provide regulatory agencies, monitoring stations, scientists and researchers with temporally and spatially resolved data (including measurements of important greenhouse gases, isotopes and pollutants) necessary for compliance monitoring, hot-spot detection, as well as cap and trade, at any location. Details of extended measurement campaigns (including lessons learned) at the various field sites (urban and rural environments) will be presented.
Enomoto, Catherine B.; Trippi, Michael H.; Higley, Debra K.; Rouse, William A.; Dulong, Frank T.; Klett, Timothy R.; Mercier, Tracey J.; Brownfield, Michael E.; Leathers-Miller, Heidi M.; Finn, Thomas M.; Marra, Kristen R.; Le, Phuong A.; Woodall, Cheryl A.; Schenk, Christopher J.
2018-04-19
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 10.7 trillion cubic feet of natural gas in Upper Devonian shales of the Appalachian Basin Province.
DOT National Transportation Integrated Search
1985-05-01
Laboratory rats were exposed continuously to measured atmospheric concentrations of hydrogen chloride (HC1) gas until they expired. The exposure time required to produce lethality was measured, as was the time at which physical incapacitation occurre...
49 CFR 192.935 - What additional preventive and mitigative measures must an operator take?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.935 What additional preventive and mitigative...
77 FR 17119 - Pipeline Safety: Cast Iron Pipe (Supplementary Advisory Bulletin)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... national attention and highlight the need for continued safety improvements to aging gas pipeline systems... 26, 1992) covering the continued use of cast iron pipe in natural gas distribution pipeline systems...
West, John B; Crouch, Daniel R; Fine, Janelle M; Makadia, Dipen; Wang, Daniel L; Prisk, G Kim
2018-02-13
It would be valuable to have a noninvasive method of measuring impaired pulmonary gas exchange in patients with lung disease and thus reduce the need for repeated arterial punctures. This study reports the results of using a new test in a group of outpatients attending a pulmonary clinic. Inspired and expired partial pressure of oxygen (PO 2 ) and Pco 2 are continually measured by small, rapidly responding analyzers. The arterial PO 2 is calculated from the oximeter blood oxygen saturation level and the oxygen dissociation curve. The PO 2 difference between the end-tidal gas and the calculated arterial value is called the oxygen deficit. Studies on 17 patients with a variety of pulmonary diseases are reported. The mean ± SE oxygen deficit was 48.7 ± 3.1 mm Hg. This finding can be contrasted with a mean oxygen deficit of 4.0 ± 0.88 mm Hg in a group of 31 normal subjects who were previously studied (P < .0001). The analysis emphasizes the value of measuring the composition of alveolar gas in determining ventilation-perfusion ratio inequality. This factor is largely ignored in the classic index of impaired pulmonary gas exchange using the ideal alveolar PO 2 to calculate the alveolar-arterial oxygen gradient. The results previously reported in normal subjects and the present studies suggest that this new noninvasive test will be valuable in assessing abnormal gas exchange in the clinical setting. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Dynamic Contraction of the Positive Column of a Self-Sustained Glow Discharge in Molecular Gas Flow
NASA Astrophysics Data System (ADS)
Shneider, Mikhail
2014-10-01
Contraction of the gas discharge, when current contracts from a significant volume of weakly ionized plasma into a thin arc channel, was attracted attention of scientists for more than a century. Studies of the contraction (also called constriction) mechanisms, besides carrying interesting science, are of practical importance, especially when contraction should be prevented. A set of time-dependent two-dimensional equations for the non-equilibrium weakly-ionized nitrogen/ air plasma is formulated. The process is described by a set of time-dependent continuity equations for the electrons, positive and negative ions; gas and vibrational temperature; by taking into account the convective heat and plasma losses by the transverse flux. Transition from the uniform to contracted state was analyzed. It was shown that such transition experiences a hysteresis, and that the critical current of the transition increases when the pressure (gas density) drops. Possible coexistence of the contracted and uniform state of the plasma in the discharge where the current flows along the density gradient of the background gas was discussed. In this talk the problems related to the dynamic contraction of the current channel inside a quasineutral positive column of a self-sustained glow discharge in molecular gas in a rectangular duct with convection cooling will be discussed. Study presented in this talk was stimulated by the fact that there are large number of experiments on the dynamic contraction of a glow discharge in nitrogen and air flows and a many of possible applications. Similar processes play a role in the powerful gas-discharge lasers. In addition, the problem of dynamic contraction in the large volume of non-equilibrium weakly ionized plasma is closely related to the problem of streamer to leader transitions in lightning and blue jets.
49 CFR 192.625 - Odorization of gas.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; (iii) A gas dehydration plant; or (iv) An industrial plant using gas in a process where the presence of... 49 Transportation 3 2010-10-01 2010-10-01 false Odorization of gas. 192.625 Section 192.625... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS...
40 CFR 98.404 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.404... determine the quantity of NGLs and natural gas using methods in common use in the industry for billing... National Standards Institute (ANSI), the American Gas Association (AGA), the American Society of Mechanical...
40 CFR 98.407 - Records that must be retained.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.407... support volumes of natural gas and NGLs that are reported under this part. (b) Records documenting any... on the accuracy of measurements of volumes of natural gas and NGLs delivered to customers or on...
40 CFR 98.406 - Data reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.406 Data..., isobutane, and pentanes plus. (3) Annual volumes in Mscf of natural gas received for processing. (4) Annual... report for each LDC shall contain the following information. (1) Annual volume in Mscf of natural gas...
40 CFR 98.407 - Records that must be retained.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.407... volumes of natural gas and NGLs that are reported under this part. (b) Records documenting any estimates... on the accuracy of measurements of volumes of natural gas and NGLs delivered to customers or on...
40 CFR 98.406 - Data reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.406 Data..., isobutane, and pentanes plus. (3) Annual volumes in Mscf of natural gas received for processing. (4) Annual... Mscf of natural gas received by the LDC at its city gate stations for redelivery on the LDC's...
40 CFR 98.406 - Data reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.406 Data..., isobutane, and pentanes plus. (3) Annual volumes in Mscf of natural gas received for processing. (4) Annual... Mscf of natural gas received by the LDC at its city gate stations for redelivery on the LDC's...
40 CFR 98.404 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.404... determine the quantity of NGLs and natural gas using methods in common use in the industry for billing... National Standards Institute (ANSI), the American Gas Association (AGA), the American Society of Mechanical...
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403... natural gas processing plants from local production, received as a liquid and vaporized for delivery, or... local production, or natural gas that was received as a liquid, vaporized and delivered, and any other...
40 CFR 98.407 - Records that must be retained.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.407... volumes of natural gas and NGLs that are reported under this part. (b) Records documenting any estimates... on the accuracy of measurements of volumes of natural gas and NGLs delivered to customers or on...
40 CFR 98.406 - Data reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.406 Data..., isobutane, and pentanes plus. (3) Annual volumes in Mscf of natural gas received for processing. (4) Annual... shall contain the following information. (1) Annual volume in Mscf of natural gas received by the LDC at...
40 CFR 98.407 - Records that must be retained.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.407... volumes of natural gas and NGLs that are reported under this part. (b) Records documenting any estimates... on the accuracy of measurements of volumes of natural gas and NGLs delivered to customers or on...
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403... (Mscf) for natural gas and bbl for NGLs). HHVh = Higher heating value of product “h” supplied (MMBtu... LDC shall follow the procedures below. (1) For natural gas that is received for redelivery to...
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403... (Mscf) for natural gas and bbl for NGLs). HHVh = Higher heating value of product “h” supplied (MMBtu... LDC shall follow the procedures below. (1) For natural gas that is received for redelivery to...
40 CFR 98.404 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.404... determine the quantity of NGLs and natural gas using methods in common use in the industry for billing... National Standards Institute (ANSI), the American Gas Association (AGA), the American Society of Mechanical...
40 CFR 98.404 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.404... determine the quantity of NGLs and natural gas using methods in common use in the industry for billing... National Standards Institute (ANSI), the American Gas Association (AGA), the American Society of Mechanical...
40 CFR 98.406 - Data reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.406 Data..., isobutane, and pentanes plus. (3) Annual volumes in Mscf of natural gas received for processing. (4) Annual... Mscf of natural gas received by the LDC at its city gate stations for redelivery on the LDC's...
40 CFR 98.407 - Records that must be retained.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.407... natural gas and NGLs that are reported under this part. (b) Records documenting any estimates of missing... accuracy of measurements of volumes of natural gas and NGLs delivered to customers or on behalf of...
40 CFR 98.404 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.404... determine the quantity of NGLs and natural gas using methods in common use in the industry for billing... National Standards Institute (ANSI), the American Gas Association (AGA), the American Society of Mechanical...
40 CFR 98.403 - Calculating GHG emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.403... (Mscf) for natural gas and bbl for NGLs). HHVh = Higher heating value of product “h” supplied (MMBtu... LDC shall follow the procedures below. (1) For natural gas that is received for redelivery to...
40 CFR 98.236 - Data reporting requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment type. (8) For gas emitted from produced oil sent to atmospheric tanks: (i) For wellhead gas-liquid... collectively for Calculation Methodology 3 and 4 of § 98.233(j). (iii) For wellhead gas-liquid separators and... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Petroleum and Natural Gas Systems § 98.236 Data reporting...
NASA Astrophysics Data System (ADS)
Sun, Y. W.; Liu, C.; Xie, P. H.; Hartl, A.; Chan, K. L.; Tian, Y.; Wang, W.; Qin, M.; Liu, J. G.; Liu, W. Q.
2015-12-01
In this paper, we demonstrate achieving accurate industrial SO2 emissions monitoring using a portable multi-channel gas analyzer with an optimized retrieval algorithm. The introduced analyzer features with large dynamic measurement range and correction of interferences from other co-existing infrared absorbers, e.g., NO, CO, CO2, NO2, CH4, HC, N2O and H2O. Both effects have been the major limitations of industrial SO2 emissions monitoring. The multi-channel gas analyzer measures 11 different wavelength channels simultaneously in order to achieve correction of several major problems of an infrared gas analyzer, including system drift, conflict of sensitivity, interferences among different infrared absorbers and limitation of measurement range. The optimized algorithm makes use of a 3rd polynomial rather than a constant factor to quantify gas-to-gas interference. The measurement results show good performance in both linear and nonlinear range, thereby solving the problem that the conventional interference correction is restricted by the linearity of both intended and interfering channels. The result implies that the measurement range of the developed multi-channel analyzer can be extended to the nonlinear absorption region. The measurement range and accuracy are evaluated by experimental laboratory calibration. An excellent agreement was achieved with a Pearson correlation coefficient (r2) of 0.99977 with measurement range from ~5 ppmv to 10 000 ppmv and measurement error <2 %. The instrument was also deployed for field measurement. Emissions from 3 different factories were measured. The emissions of these factories have been characterized with different co-existing infrared absorbers, covering a wide range of concentration levels. We compared our measurements with the commercial SO2 analyzers. The overall good agreements are achieved.
Field intercomparison of four methane gas analyzers suitable for eddy covariance flux measurements
NASA Astrophysics Data System (ADS)
Peltola, O.; Mammarella, I.; Haapanala, S.; Burba, G.; Vesala, T.
2013-06-01
Performances of four methane gas analyzers suitable for eddy covariance measurements are assessed. The assessment and comparison was performed by analyzing eddy covariance data obtained during summer 2010 (1 April to 26 October) at a pristine fen, Siikaneva, Southern Finland. High methane fluxes with pronounced seasonality have been measured at this fen. The four participating methane gas analyzers are commercially available closed-path units TGA-100A (Campbell Scientific Inc., USA), RMT-200 (Los Gatos Research, USA), G1301-f (Picarro Inc., USA) and an early prototype open-path unit Prototype-7700 (LI-COR Biosciences, USA). The RMT-200 functioned most reliably throughout the measurement campaign, during low and high flux periods. Methane fluxes from RMT-200 and G1301-f had the smallest random errors and the fluxes agree remarkably well throughout the measurement campaign. Cospectra and power spectra calculated from RMT-200 and G1301-f data agree well with corresponding temperature spectra during a high flux period. None of the gas analyzers showed statistically significant diurnal variation for methane flux. Prototype-7700 functioned only for a short period of time, over one month, in the beginning of the measurement campaign during low flux period, and thus, its overall accuracy and season-long performance were not assessed. The open-path gas analyzer is a practical choice for measurement sites in remote locations due to its low power demand, whereas for G1301-f methane measurements interference from water vapor is straightforward to correct since the instrument measures both gases simultaneously. In any case, if only the performance in this intercomparison is considered, RMT-200 performed the best and is the recommended choice if a new fast response methane gas analyzer is needed.
Fürhacker, M; Pressl, A; Allabashi, R
2003-09-01
Mixtures of different amines including tertiary amines (methyldiethanolamine, MDEA) are commonly used for the removal of CO2 from gas mixtures or in gas sweetening processes for the extraction of CO2 and H2S. The absorber solutions used can be released into the industrial waste water due to continuous substitution of degraded MDEA, periodically cleaning processes or an accidental spill. In this study, the aerobic biodegradability of MDEA was investigated in a standardised batch test and a continuous flow experiment (40 l/d). The results of the batch test indicated that the MDEA-solution was non-biodegradable during the test period of 28 days, whereas the continuous flow experiments showed biodegradation of more than 96% based on TOC-measurements. This was probably due to the adaptation of the microorganisms to this particular waste water contamination during continuous flow experiment.
Hunt, Andrew G.
2015-08-12
This report addresses the standard operating procedures used by the U.S. Geological Survey’s Noble Gas Laboratory in Denver, Colorado, U.S.A., for the measurement of dissolved gases (methane, nitrogen, oxygen, and carbon dioxide) and noble gas isotopes (helium-3, helium-4, neon-20, neon-21, neon-22, argon-36, argon-38, argon-40, kryton-84, krypton-86, xenon-103, and xenon-132) dissolved in water. A synopsis of the instrumentation used, procedures followed, calibration practices, standards used, and a quality assurance and quality control program is presented. The report outlines the day-to-day operation of the Residual Gas Analyzer Model 200, Mass Analyzer Products Model 215–50, and ultralow vacuum extraction line along with the sample handling procedures, noble gas extraction and purification, instrument measurement procedures, instrumental data acquisition, and calculations for the conversion of raw data from the mass spectrometer into noble gas concentrations per unit mass of water analyzed. Techniques for the preparation of artificial dissolved gas standards are detailed and coupled to a quality assurance and quality control program to present the accuracy of the procedures used in the laboratory.
NASA Astrophysics Data System (ADS)
Aochi, Hideo; Burnol, André
2018-05-01
The source mechanism of the M L 4.0 25 April 2016 Lacq earthquake (Aquitaine Basin, South-West France) is analyzed from the available public data and discussed with respect to the geometry of the nearby Lacq gas field. It is one of the biggest earthquakes in the area in the past few decades of gas extraction and the biggest after the end of gas exploitation in 2013. The routinely obtained location shows its hypocenter position inside the gas reservoir. We first analyze its focal mechanism through regional broad-band seismograms recorded in a radius of about 50 km epicentral distances and obtain EW running normal faulting above the reservoir. While the solution is stable using regional data only, we observe a large discrepancy between the recorded data on nearby station URDF and the forward modeling up to 1 Hz. We then look for the best epicenter position through performing wave propagation simulations and constraining the potential source area by the peak ground velocity (PGV). The resulting epicentral position is a few to several km away to the north or south direction with respect to station URDF such that the simulated particle motions are consistent with the observation. The initial motion of the seismograms shows that the epicenter position in the north from URDF is preferable, indicating the north-east of the Lacq reservoir. This study is an application of full waveform simulations and characterization of near-field ground motion in terms of an engineering factor such as PGV. The finally obtained solution gives a moment magnitude of M w 3.9 and the best focal depth of 4 km, which corresponds to the crust above the reservoir rather than its interior. This position is consistent with the tendency of Coulomb stress change due to a compaction at 5 km depth in the crust. Therefore, this earthquake can be interpreted as a relaxation of the shallow crust due to a deeper gas reservoir compaction so that the occurrence of similar events cannot be excluded in the near future. It would be necessary to continue monitoring such local induced seismicity in order to better understand the reservoir/overburden behavior and better assess the local seismic hazard even after the end of gas exploitation.
NASA Astrophysics Data System (ADS)
Srikanth, A.; Manikandan, M.
2018-02-01
The present study investigates the microstructure and mechanical properties of joints fabricated by Continuous and pulsed current gas tungsten arc welded alloy 600. Welding was done by autogenous mode. The macro examination was carried out to evaluate the welding defects in the weld joints. Optical and Scanning Electron Microscope (SEM) were performed to assess the microstructural changes in the fusion zone. Energy Dispersive Spectroscopy (EDS) analysis was carried to evaluate the microsegregation of alloying elements in the fusion zone. The tensile test was conducted to assess the strength of the weld joints. The results show that no welding defects were observed in the fusion zones of Continuous and Pulsed current Gas Tungsten Arc Welding. The refined microstructure was found in the pulsed current compared to continuous current mode. Microsegregation was not noticed in the weld grain boundary of continuous and pulsed current mode. The pulsed current shows improved mechanical properties compared to the continuous current mode.
Akmalov, Artem E; Chistyakov, Alexander A; Kotkovskii, Gennadii E
2017-08-01
Application of laser-induced desorption was investigated as a method of increasing the efficiency of gas phase analyzers on principles of field asymmetric ion mobility spectrometry. Mass spectrometric data of investigations of laser desorption of pentaerythritoltetranitrate molecules and cyclotetramethylenetetranitramine molecules from quartz substrate under vacuum were obtained. Laser sources a Nd 3+ :YAG with nanosecond pulse duration (λ = 532 nm) and a continuous wave diode laser (λ = 440 nm) were used. It was shown that both laser sources have different desorption abilities. This is expressed in various time of appearance of desorbed products that is caused by different heating mechanisms of surface layer. The desorbed quantity under action of both laser sources exceeds the detection threshold for all modern gas phase analyzers. It should be noted that despite the presence of surface dissociation of explosives under laser radiation, the quantity of nondissociated molecules is large enough for detection by ion mobility and field asymmetric ion mobility spectrometers. The optimal parameters of laser radiation for effective removal (evaporation) molecules of low-volatile compounds from surfaces are defined. The conclusion about preferable use of a Nd 3+ :YAG laser for increasing the detection ability of detectors based on ion mobility spectrometry was made.
CO adsorption on N2-precovered NaY faujasite: a FTIR analysis of the resulting adsorbed species.
Cairon, Olivier
2013-08-26
To productively complete the information regarding the reversible adsorption of a gas mixture on the micropores of cationic zeolites, the adsorption of the two gases N2 and CO on NaY faujasite is taken as a model case study. We analyze herein CO adsorption (77 K) on two distinct N2-precovered NaY sets (low and medium). We outline the continuous desorption of N2 adducts during CO admittance to full N2 desorption for the highest CO loadings. These features contrast with preceding results obtained for N2 loading on CO-precovered NaY. By comparing these results with the sole CO admission and combining both studies regarding the co-adsorption sets, we demonstrate the influence of the basic strength of the two gases regarding the nature of the surface-adsorbed species formed. We also propose and discuss a hypothesis regarding the formation of adsorbed mixed species having both N2 and CO as ligands. These new findings strengthen the statistical response of IR signatures as a helpful proposal for analyzing adsorbed species and their assignments. This survey completes the molecular understanding of gas-mixture adsorption that lacks experimental data to date. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fast automotive diesel exhaust measurement using quantum cascade lasers
NASA Astrophysics Data System (ADS)
Herbst, J.; Brunner, R.; Lambrecht, A.
2013-12-01
Step by step, US and European legislations enforce the further reduction of atmospheric pollution caused by automotive exhaust emissions. This is pushing automotive development worldwide. Fuel efficient diesel engines with SCRtechnology can impede NO2-emission by reduction with NH3 down to the ppm range. To meet the very low emission limits of the Euro6 resp. US NLEV (National Low Emission Vehicle) regulations, automotive manufacturers have to optimize continuously all phases of engine operation and corresponding catalytic converters. Especially nonstationary operation holds a high potential for optimizing gasoline consumption and further reducing of pollutant emissions. Test equipment has to cope with demanding sensitivity and speed requirements. In the past Fraunhofer IPM has developed a fast emission analyzer called DEGAS (Dynamic Exhaust Gas Analyzer System), based on cryogenically cooled lead salt lasers. These systems have been used at Volkswagen AG`s test benches for a decade. Recently, IPM has developed DEGAS-Next which is based on cw quantum cascade lasers and thermoelectrically cooled detectors. The system is capable to measure three gas components (i.e. NO, NO2, NH3) in two channels with a time resolution of 20 ms and 1 ppm detection limits. We shall present test data and a comparison with fast FTIR measurements.
49 CFR 192.925 - What are the requirements for using External Corrosion Direct Assessment (ECDA)?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.925 What are the requirements for using...
Assessment of continuous oil and gas resources in the Pannonian Basin Province, Hungary, 2016
Schenk, Christopher J.; Klett, Timothy R.; Le, Phuong A.; Brownfield, Michael E.; Leathers-Miller, Heidi M.
2017-06-29
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 119 million barrels of oil and 944 billion cubic feet of gas in the Hungarian part of the Pannonian Basin Province.
Schenk, Christopher J.; Tennyson, Marilyn E.; Mercier, Tracey J.; Woodall, Cheryl A.; Finn, Thomas M.; Brownfield, Michael E.; Le, Phuong A.; Klett, Timothy R.; Gaswirth, Stephanie B.; Marra, Kristen R.; Leathers-Miller, Heidi M.; Potter, Christopher J.
2018-02-07
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 2.0 billion barrels of oil and 20.3 trillion cubic feet of gas in the Bohaiwan Basin Province, China.
49 CFR 192.1009 - What must an operator report when compression couplings fail?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1009 What must an operator report when compression...
49 CFR 192.909 - How can an operator change its integrity management program?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.909 How can an operator change its integrity management...
49 CFR 192.943 - When can an operator deviate from these reassessment intervals?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.943 When can an operator deviate from these reassessment...
High voltage gas insulated transmission line with continuous particle trapping
Cookson, Alan H.; Dale, Steinar J.
1983-01-01
This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.
Marra, Kristen R.; Charpentier, Ronald R.; Schenk, Christopher J.; Lewan, Michael D.; Leathers-Miller, Heidi M.; Klett, Timothy R.; Gaswirth, Stephanie B.; Le, Phuong A.; Mercier, Tracey J.; Pitman, Janet K.; Tennyson, Marilyn E.
2016-07-15
In 2015, the U.S. Geological Survey (USGS) released an updated assessment of undiscovered, technically recoverable shale gas and shale oil resources of the Mississippian Barnett Shale in north-central Texas (Marra and others, 2015). The Barnett Shale was assessed using the standard continuous (unconventional) methodology established by the USGS for two assessment units (AUs): (1) Barnett Continuous Gas AU, and (2) Barnett Mixed Continuous Gas and Oil AU. A third assessment unit, the Western Barnett Continuous Oil AU, was also defined but was not quantitatively assessed because of limited data within the extent of the AU. The purpose of this report is to provide supplemental documentation of the quantitative input parameters applied in the Barnett Shale assessment.
High-bandwidth continuous-flow arc furnace
Hardt, David E.; Lee, Steven G.
1996-01-01
A high-bandwidth continuous-flow arc furnace for stream welding applications includes a metal mass contained in a crucible having an orifice. A power source charges an electrode for generating an arc between the electrode and the mass. The arc heats the metal mass to a molten state. A pressurized gas source propels the molten metal mass through the crucible orifice in a continuous stream. As the metal is ejected, a metal feeder replenishes the molten metal bath. A control system regulates the electrode current, shielding gas pressure, and metal source to provide a continuous flow of molten metal at the crucible orifice. Independent control over the electrode current and shield gas pressure decouples the metal flow temperature and the molten metal flow rate, improving control over resultant weld characteristics.
High-bandwidth continuous-flow arc furnace
Hardt, D.E.; Lee, S.G.
1996-08-06
A high-bandwidth continuous-flow arc furnace for stream welding applications includes a metal mass contained in a crucible having an orifice. A power source charges an electrode for generating an arc between the electrode and the mass. The arc heats the metal mass to a molten state. A pressurized gas source propels the molten metal mass through the crucible orifice in a continuous stream. As the metal is ejected, a metal feeder replenishes the molten metal bath. A control system regulates the electrode current, shielding gas pressure, and metal source to provide a continuous flow of molten metal at the crucible orifice. Independent control over the electrode current and shield gas pressure decouples the metal flow temperature and the molten metal flow rate, improving control over resultant weld characteristics. 4 figs.
40 CFR 1065.362 - Non-stoichiometric raw exhaust FID O2 interference verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... air source during testing, use zero air as the FID burner's air source for this verification. (4) Zero the FID analyzer using the zero gas used during emission testing. (5) Span the FID analyzer using a span gas that you use during emission testing. (6) Check the zero response of the FID analyzer using...
Quality assured measurements of animal building emissions: gas concentrations.
Heber, Albert J; Ni, Ji-Qin; Lim, Teng T; Tao, Pei-Chun; Schmidt, Amy M; Koziel, Jacek A; Beasley, David B; Hoff, Steven J; Nicolai, Richard E; Jacobson, Larry D; Zhang, Yuanhui
2006-10-01
Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.
Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.
2009-01-01
Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N values. Comparative ??13C and ??15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional SO2 Emissions Data Protocol for Gas-Fired and Oil-Fired Units D Appendix D to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. D Appendix D to Part 75—Optional SO2 Emissions Data...
Sequential continuous flow processes for the oxidation of amines and azides by using HOF·MeCN.
McPake, Christopher B; Murray, Christopher B; Sandford, Graham
2012-02-13
The generation and use of the highly potent oxidising agent HOF·MeCN in a controlled single continuous flow process is described. Oxidations of amines and azides to corresponding nitrated systems by using fluorine gas, water and acetonitrile by sequential gas-liquid/liquid-liquid continuous flow procedures are reported. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Farmery, A D; Hahn, C E
2001-04-01
The use of sidestream infrared and paramagnetic clinical gas analyzers is widespread in anesthesiology and respiratory medicine. For most clinical applications, these instruments are entirely satisfactory. However, their ability to measure breath-by-breath volumetric gas fluxes, as required for measurement of airway dead space, oxygen uptake, and so on, is usually inferior to that of the mass spectrometer, and this is thought to be due, in part, to their slower response times. We describe how volumetric gas analysis with the Datex Ultima analyzer, although reasonably accurate for spontaneous ventilation, gives very inaccurate results in conditions of positive-pressure ventilation. We show that this problem is a property of the gas sampling system rather than the technique of gas analysis itself. We examine the source of this error and describe how cyclic changes in airway pressure result in variations in the flow rate of the gas within the sampling catheter. This results in the phenomenon of "time distortion," and the resultant gas concentration signal becomes a nonlinear time series. This corrupted signal cannot be aligned or integrated with the measured flow signal. We describe a method to correct for this effect. With the use of this method, measurements required for breath-by-breath gas-exchange models can be made easily and reliably in the clinical setting.
DOE R&D Accomplishments Database
Freifeld, Barry M.; Kneafsey, Timothy J.; Tomutsa, Liviu; Stern, Laura A.; Kirby, Stephen H.
2002-02-28
X-ray computed tomography (CT) is a method that has been used extensively in laboratory experiments for measuring rock properties and fluid transport behavior. More recently, CT scanning has been applied successfully to detect the presence and study the behavior of naturally occurring hydrates. In this study, we used a modified medical CT scanner to image and analyze the progression of a dissociation front in a synthetic methane hydrate/sand mixture. The sample was initially scanned under conditions at which the hydrate is stable (atmospheric pressure and liquid nitrogen temperature, 77 K). The end of the sample holder was then exposed to the ambient air, and the core was continuously scanned as dissociation occurred in response to the rising temperature. CT imaging captured the advancing dissociation front clearly and accurately. The evolved gas volume was monitored as a function of time. Measured by CT, the advancing hydrate dissociation front was modeled as a thermal conduction problem explicitly incorporating the enthalpy of dissociation, using the Stefan moving-boundary-value approach. The assumptions needed to perform the analysis consisted of temperatures at the model boundaries. The estimated value for thermal conductivity of 2.6 W/m K for the remaining water ice/sand mixture is higher than expected based on conduction alone; this high value may represent a lumped parameter that incorporates the processes of heat conduction, methane gas convection, and any kinetic effects that occur during dissociation. The technique presented here has broad implications for future laboratory and field testing that incorporates geophysical techniques to monitor gas hydrate dissociation.
Organiscak, J.A.; Beck, T.W.
2015-01-01
The U.S. National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently studied several redirected scrubber discharge configurations in its full-scale continuous miner gallery for both dust and gas control when using an exhaust face ventilation system. Dust and gas measurements around the continuous mining machine in the laboratory showed that the conventional scrubber discharge directed outby the face with a 12.2-m (40-ft) exhaust curtain setback appeared to be one of the better configurations for controlling dust and gas. Redirecting all the air toward the face equally up both sides of the machine increased the dust and gas concentrations around the machine. When all of the air was redirected toward the face on the off-curtain side of the machine, gas accumulations tended to be reduced at the face, at the expense of increased dust levels in the return and on the curtain side of the mining machine. A 6.1-m (20-ft) exhaust curtain setback without the scrubber operating resulted in the lowest dust levels around the continuous mining machine, but this configuration resulted in some of the highest levels of dust in the return and gas on the off-curtain side of the mining face. Two field studies showed some similarities to the laboratory findings, with elevated dust levels at the rear corners of the continuous miner when all of the scrubber exhaust was redirected toward the face either up the off-tubing side or equally up both sides of the mining machine. PMID:26251566
Requirements for long-life operation of inert gas hollow cathodes: Preliminary report
NASA Technical Reports Server (NTRS)
Verhey, Timothy R.; Macrae, Gregory S.
1990-01-01
An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.
Automated life-detection experiments for the Viking mission to Mars
NASA Technical Reports Server (NTRS)
Klein, H. P.
1974-01-01
As part of the Viking mission to Mars in 1975, an automated set of instruments is being built to test for the presence of metabolizing organisms on that planet. Three separate modules are combined in this instrument so that samples of the Martian surface can be subjected to a broad array of experimental conditions so as to measure biological activity. The first, the Pyrolytic Release Module, will expose surface samples to a mixture of C-14O and C-14O2 in the presence of Martian atmosphere and a light source that simulates the Martian visible spectrum. The assay system is designed to determine the extent of assimilation of CO or CO2 into organic compounds. The Gas Exchange Module will incubate surface samples in a humidified CO2 atmosphere. At specified times, portions of the incubation atmosphere will be analyzed by gas chromatography to detect the release or uptake of CO2 and several additional gases. The Label Release Module will incubate surface samples with a dilute aqueous solution of simple radioactive organic substrates in Martian atmosphere, and the gas phase will be monitored continuously for the release of labeled CO2.
A review of various nozzle range of wire arc spray on FeCrBMnSi metal coating
NASA Astrophysics Data System (ADS)
Purwaningsih, Hariyati; Rochiem, Rochman; Suchaimi, Muhammad; Jatimurti, Wikan; Wibisono, Alvian Toto; Kurniawan, Budi Agung
2018-04-01
Low Temperature Hot Corrosion (LTHC) is type of hot corrosion which occurred on 700-800°C and usually on turbine blades. So, as a result the material of turbine blades is crack and degredation of rotation efficiency. Hot corrosion protection with the use of barrier that separate substrate and environment is one of using metal surface coating, wire arc spray method. This study has a purpose to analyze the effect of nozzle distance and gas pressure on FeCrBMnSi coating process using wire arc spray method on thermal resistance. The parameter of nozzle distance and gas pressure are used, resulted the best parameter on distance 400 mm and gas pressure 3 bar which has the bond strength of 12,58 MPa with porosity percentage of 5,93% and roughness values of 16,36 µm. While the examination of thermal cycle which by heating and cooling continuously, on the coating surface is formed oxide compound (Fe3O4) which cause formed crack propagation and delamination. Beside that hardness of coating surface is increase which caused by precipitate boride (Fe9B)0,2
Is the U.S. shale gas boom having an effect on the European gas market?
NASA Astrophysics Data System (ADS)
Yao, Isaac
This thesis focuses on the impact of the American shale gas boom on the European natural gas market. The study presents different tests in order to analyze the dynamics of natural gas prices in the U.S., U.K. and German natural gas market. The question of cointegration between these different markets are analyzed using several tests. More specifically, the ADF tests for the presence of a unit root. The error correction model test and the Johansen cointegration procedure are applied in order to accept or reject the hypothesis of an integrated market. The results suggest no evidence of cointegration between these markets. There currently is no evidence of an impact of the U.S. shale gas boom on the European market.
Johnson, Ronald C.; Finn, Thomas M.
2003-01-01
The U.S. Geological Survey, in a recent assessment of the undiscovered oil and gas resources in the Southwestern Wyoming Province using a Total Petroleum System (TPS) approach, estimated a mean of 84.6 trillion cubic feet of gas (TCFG), 131 million barrels of oil (MMBO) and 2.6 billion barrels of natural gas liquids (BBNGL) that have the potential to be added to reserves over the next 30 years. Only a fraction of this, however, may be economically recoverable . Of the total estimate of 84.6 TCFG, a mean of 25.78 TCFG is in continuous-type reservoirs in the Mesaverde TPS. The Mesaverde TPS is defined as all reservoirs predominantly containing gas derived from the Mesaverde Group east of the pinchout of the Lewis Shale, which acts as a top seal separating the Mesaverde TPS from the overlying Lewis TPS. Continuous-type reservoirs in the Mesaverde TPS were subdivided into the Almond Continuous Gas Assessment Unit (AU) (mean of 13.35 TCFG), Rock Springs-Ericson Continuous Gas AU (mean of 12.18 TCFG), and the Mesaverde Coalbed Gas AU (mean of 0.25 TCFG). Geologic analysis was used to determine the favorable ?sweet spots? for potential gas resources. The Almond AU has been heavily explored at depths less than 11,000 ft, thus additions to reserves will most likely be the result of infill drilling in existing fields and the discovery of sweet spots at depths greater than 11,000 ft. There is much uncertainty in the size of undiscovered resource in the Rock Springs-Ericson AU because potential reservoirs are only sparsely explored. Only a small fraction of in-place coal-bed gas is considered to be recoverable because of low permeability and problems posed by produced water.
Microfabricated fuel heating value monitoring device
Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM
2010-05-04
A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Applications for Authorization To Import or Export Natural Gas § 590.201 General. (a) Any person seeking authorization to import or export natural gas into or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Applications for Authorization To Import or Export Natural Gas § 590.201 General. (a) Any person seeking authorization to import or export natural gas into or...
49 CFR 192.1013 - When may an operator deviate from required periodic inspections under this part?
Code of Federal Regulations, 2011 CFR
2011-10-01
... to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1013 When may an operator...
49 CFR 192.1013 - When may an operator deviate from required periodic inspections under this part?
Code of Federal Regulations, 2013 CFR
2013-10-01
... to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1013 When may an operator...
49 CFR 192.1013 - When may an operator deviate from required periodic inspections under this part?
Code of Federal Regulations, 2012 CFR
2012-10-01
... to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1013 When may an operator...
Schenk, Christopher J.; Tennyson, Marilyn E.; Mercier, Tracey J.; Gaswirth, Stephanie B.; Marra, Kristen R.; Le, Phoung A.; Pitman, Janet K.; Brownfield, Michael E.; Hawkins, Sarah J.; Leathers-Miller, Heidi M.; Finn, Thomas M.; Klett, Timothy R.
2017-03-27
Using a geology-based assessment methodology, the U.S. Geological Survey estimated undiscovered, technically recoverable mean continuous resources of 656 million barrels of oil and 5.7 trillion cubic feet of gas in the Maracaibo Basin Province, Venezuela and Colombia.
49 CFR 192.913 - When may an operator deviate its program from certain requirements of this subpart?
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.913 When may an operator deviate its program...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192...
49 CFR 192.1013 - When may an operator deviate from required periodic inspections under this part?
Code of Federal Regulations, 2010 CFR
2010-10-01
... to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1013 When may an operator...
26 CFR 1.611-5 - Depreciation of improvements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) INCOME TAXES (CONTINUED) Natural Resources § 1.611-5 Depreciation of improvements. (a) In general. Section 611 provides in the case of mines, oil and gas wells, other natural deposits, and timber that...). (b) Special rules for mines, oil and gas wells, other natural deposits and timber. (1) For principles...
Schenk, Christopher J.; Brownfield, Michael E.; Tennyson, Marilyn E.; Le, Phuong A.; Mercier, Tracey J.; Finn, Thomas M.; Hawkins, Sarah J.; Gaswirth, Stephanie B.; Marra, Kristen R.; Klett, Timothy R.; Leathers-Miller, Heidi M.; Woodall, Cheryl A.
2017-09-22
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 0.45 billion barrels of oil and 1.0 trillion cubic feet of gas in the Middle and Upper Magdalena Basins, Colombia.
Schenk, Christopher J.; Tennyson, Marilyn E.; Mercier, Tracey J.; Hawkins, Sarah J.; Gaswirth, Stephanie B.; Marra, Kristen R.; Klett, Timothy R.; Le, Phuong A.; Brownfield, Michael E.; Woodall, Cheryl A.
2017-08-17
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable continuous resources of 35.1 trillion cubic feet of gas in the Amu Darya Basin Province of Turkmenistan, Uzbekistan, Iran, and Afghanistan.
Assessment of continuous oil and gas resources in the Neuquén Basin Province, Argentina, 2016
Schenk, Christopher J.; Klett, Timothy R.; Tennyson, Marilyn E.; Mercier, Tracey J.; Pitman, Janet K.; Gaswirth, Stephanie B.; Finn, Thomas M.; Brownfield, Michael E.; Le, Phuong A.; Leathers-Miller, Heidi M.; Marra, Kristen R.
2017-05-23
Using a geology-based assessment methodology, the U.S. Geological Survey assessed undiscovered, technically recoverable mean continuous resources of 14.4 billion barrels of oil and 38 trillion cubic feet of gas in the Neuquén Basin Province, Argentina.
40 CFR 65.111 - Standards: Pressure relief devices in gas/vapor service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Pressure relief devices in gas/vapor service. 65.111 Section 65.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.111 Standards...
Assessment of continuous oil and gas resources of the South Sumatra Basin Province, Indonesia, 2016
Schenk, Christopher J.; Tennyson, Marilyn E.; Klett, Timothy R.; Finn, Thomas M.; Mercier, Tracey J.; Gaswirth, Stephanie B.; Marra, Kristen R.; Le, Phuong A.; Hawkins, Sarah J.
2016-12-09
Using a geology-based assessment methodology, the U.S. Geological Survey estimated undiscovered, technically recoverable mean resources of 689 million barrels of continuous shale oil and 3.9 trillion cubic feet of shale gas in the South Sumatra Basin Province in Indonesia.
49 CFR 192.945 - What methods must an operator use to measure program effectiveness?
Code of Federal Regulations, 2010 CFR
2010-10-01
... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.945 What methods must an operator use to measure program...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.915 What knowledge...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.929 What are the...
40 CFR 98.231 - Reporting threshold.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Reporting threshold. 98.231 Section 98.231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Petroleum and Natural Gas Systems § 98.231 Reporting threshold. (a) You must report GHG emissions under this...
40 CFR 98.121 - Reporting threshold.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Reporting threshold. 98.121 Section 98.121 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Fluorinated Gas Production § 98.121 Reporting threshold. You must report GHG emissions under this subpart if your...
40 CFR 98.231 - Reporting threshold.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Reporting threshold. 98.231 Section 98.231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Petroleum and Natural Gas Systems § 98.231 Reporting threshold. (a) You must report GHG emissions under this...
40 CFR 98.231 - Reporting threshold.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Reporting threshold. 98.231 Section 98.231 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Petroleum and Natural Gas Systems § 98.231 Reporting threshold. (a) You must report GHG emissions under this...
40 CFR 98.121 - Reporting threshold.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Reporting threshold. 98.121 Section 98.121 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Fluorinated Gas Production § 98.121 Reporting threshold. You must report GHG emissions under this subpart if your...
40 CFR 98.121 - Reporting threshold.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Reporting threshold. 98.121 Section 98.121 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Fluorinated Gas Production § 98.121 Reporting threshold. You must report GHG emissions under this subpart if your...
Bult, Johannes H F; van Putten, Bram; Schifferstein, Hendrik N J; Roozen, Jacques P; Voragen, Alphons G J; Kroeze, Jan H A
2004-10-01
In continuous vigilance tasks, the number of coincident panel responses to stimuli provides an index of stimulus detectability. To determine whether this number is due to chance, panel noise levels have been approximated by the maximum coincidence level obtained in stimulus-free conditions. This study proposes an alternative method by which to assess noise levels, derived from queuing system theory (QST). Instead of critical coincidence levels, QST modeling estimates the duration of coinciding responses in the absence of stimuli. The proposed method has the advantage over previous approaches that it yields more reliable noise estimates and allows for statistical testing. The method was applied in an olfactory detection experiment using 16 panelists in stimulus-present and stimulus-free conditions. We propose that QST may be used as an alternative to signal detection theory for analyzing data from continuous vigilance tasks.
21 CFR 868.5160 - Gas machine for anesthesia or analgesia.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas machine for anesthesia or analgesia. 868.5160... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5160 Gas machine for anesthesia or analgesia. (a) Gas machine for anesthesia—(1) Identification. A gas machine for anesthesia is a...
21 CFR 868.5160 - Gas machine for anesthesia or analgesia.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas machine for anesthesia or analgesia. 868.5160... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5160 Gas machine for anesthesia or analgesia. (a) Gas machine for anesthesia—(1) Identification. A gas machine for anesthesia is a...
21 CFR 868.5160 - Gas machine for anesthesia or analgesia.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas machine for anesthesia or analgesia. 868.5160... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5160 Gas machine for anesthesia or analgesia. (a) Gas machine for anesthesia—(1) Identification. A gas machine for anesthesia is a...
Pennell, William E.; Sutton, Jr., Harry G.
1981-01-01
Method and apparatus for detecting failure in a welded connection, particrly applicable to not readily accessible welds such as those joining components within the reactor vessel of a nuclear reactor system. A preselected tag gas is sealed within a chamber which extends through selected portions of the base metal and weld deposit. In the event of a failure, such as development of a crack extending from the chamber to an outer surface, the tag gas is released. The environment about the welded area is directed to an analyzer which, in the event of presence of the tag gas, evidences the failure. A trigger gas can be included with the tag gas to actuate the analyzer.
Li, Wenjing; Zhang, Jingjing; Xue, Zhongxin; Wang, Jingming; Jiang, Lei
2018-01-24
Manipulation of gas bubble behaviors is crucial for gas bubble-related applications. Generally, the manipulation of gas bubble behaviors generally takes advantage of their buoyancy force. It is very difficult to control the transportation of gas bubbles in a specific direction. Several approaches have been developed to collect and transport bubbles in aqueous media; however, most reliable and effective manipulation of gas bubbles in aqueous media occurs on the interfaces with simple shapes (i.e., cylinder and cone shapes). Reliable strategies for spontaneous and directional transport of gas bubbles on interfaces with complex shapes remain enormously challenging. Herein, a type of 3D gradient porous network was constructed on copper wire interfaces, with rectangle, wave, and helix shapes. The superhydrophobic copper wires were immersed in water, and continuous and stable gas films then formed on the interfaces. With the assistance of the Laplace pressure gradient between two bubbles, gas bubbles (including microscopic gas bubbles) in the aqueous media were subsequently transported, continuously and directionally, on the copper wires with complex shapes. The small gas bubbles always moved to the larger ones.
Ko, Dong-Hyeon; Ren, Wurong; Kim, Jin-Oh; Wang, Jun; Wang, Hao; Sharma, Siddharth; Faustini, Marco; Kim, Dong-Pyo
2016-01-26
Gas and liquid streams are invariably separated either by a solid wall or by a membrane for heat or mass transfer between the gas and liquid streams. Without the separating wall, the gas phase is present as bubbles in liquid or, in a microsystem, as gas plugs between slugs of liquid. Continuous and direct contact between the two moving streams of gas and liquid is quite an efficient way of achieving heat or mass transfer between the two phases. Here, we report a silicon nanowire built-in microsystem in which a liquid stream flows in contact with an underlying gas stream. The upper liquid stream does not penetrate into the lower gas stream due to the superamphiphobic nature of the silicon nanowires built into the bottom wall, thereby preserving the integrity of continuous gas and liquid streams, although they are flowing in contact. Due to the superamphiphobic nature of silicon nanowires, the microsystem provides the best possible interfacial mass transfer known to date between flowing gas and liquid phases, which can achieve excellent chemical performance in two-phase organic syntheses.
A relativistic toy model for Unruh black holes
NASA Astrophysics Data System (ADS)
Carbonaro, P.
2014-08-01
We consider the wave propagation in terms of acoustic geometry in a quantum relativistic system. This reduces, in the hydrodynamic limit, to the equations which govern the motion of a relativistic Fermi-degenerate gas in one space dimension. The derivation of an acoustic metric for one-dimensional (1D) systems is in general plagued with the impossibility of defining a conformal factor. Here we show that, although the system is intrinsically one-dimensional, the Unruh procedure continues to work because of the particular structure symmetry of the model. By analyzing the dispersion relation, attention is also paid to the quantum effects on the wave propagation.
Bianchini, Gregory M.; McRae, Thomas G.
1985-01-01
Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.
NASA Astrophysics Data System (ADS)
Yamakita, Yoshihiro; Tanaka, Hideyasu; Maruyama, Ryo; Yamakado, Hideo; Misaizu, Fuminori; Ohno, Koichi
2000-08-01
A highly sensitive electron energy analyzer which utilizes a "magnetic bottle" combined with a retarding electrostatic field has been developed for Penning ionization electron spectroscopy. A beam of metastable rare-gas atoms is crossed with a continuous supersonic sample beam in the source region of the analyzer. The emitted electrons are collected by an inhomogeneous magnetic field (the magnetic bottle effect) with a high efficiency of nearly 4π solid angle, which is more than 103 times higher than that of a conventional hemispherical analyzer. The kinetic energy of electrons is analyzed by scanning the retarding field in a flight tube of the analyzer in the presence of a weak magnetic field. The velocity of the metastable atoms can also be resolved by a time-of-flight method in the present instrument. Examples of Penning ionization electron energy spectra as a function of collision energy are presented for Ar and N2 with metastable He*(2 3S) atoms. This instrument has opened the possibility for extensive studies of Penning ionization electron spectroscopy for low-density species, such as clusters, ions, electronically excited species, unstable or transient species, and large molecules with low volatility.
Simulation of gas flow in micro-porous media with the regularized lattice Boltzmann method
Wang, Junjian; Kang, Qinjun; Wang, Yuzhu; ...
2017-06-01
One primary challenge for prediction of gas flow in the unconventional gas reservoir at the pore-scale such as shale and tight gas reservoirs is the geometric complexity of the micro-porous media. In this paper, a regularized multiple-relaxation-time (MRT) lattice Boltzmann (LB) model is applied to analyze gas flow in 2-dimensional micro-porous medium reconstructed by quartet structure generation set (QSGS) on pore-scale. In this paper, the velocity distribution inside the porous structure is presented and analyzed, and the effects of the porosity and specific surface area on the rarefied gas flow and apparent permeability are examined and investigated. The simulation resultsmore » indicate that the gas exhibits different flow behaviours at various pressure conditions and the gas permeability is strongly related to the pressure. Finally, the increased porosity or the decreased specific surface area leads to the increase of the gas apparent permeability, and the gas flow is more sensitive to the pore morphological properties at low-pressure conditions.« less
Simulation of gas flow in micro-porous media with the regularized lattice Boltzmann method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Junjian; Kang, Qinjun; Wang, Yuzhu
One primary challenge for prediction of gas flow in the unconventional gas reservoir at the pore-scale such as shale and tight gas reservoirs is the geometric complexity of the micro-porous media. In this paper, a regularized multiple-relaxation-time (MRT) lattice Boltzmann (LB) model is applied to analyze gas flow in 2-dimensional micro-porous medium reconstructed by quartet structure generation set (QSGS) on pore-scale. In this paper, the velocity distribution inside the porous structure is presented and analyzed, and the effects of the porosity and specific surface area on the rarefied gas flow and apparent permeability are examined and investigated. The simulation resultsmore » indicate that the gas exhibits different flow behaviours at various pressure conditions and the gas permeability is strongly related to the pressure. Finally, the increased porosity or the decreased specific surface area leads to the increase of the gas apparent permeability, and the gas flow is more sensitive to the pore morphological properties at low-pressure conditions.« less
Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro
2016-01-01
Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis. PMID:27834896
Wandrey, C.J.; Ryder, Robert T.; Nuccio, Vito F.; Aggen, Kerry L.
1997-01-01
In order to best preserve and manage our energy and natural resources we must understand the relationships between these resources and the impacts of their development. To further this understanding the U.S. Geological Survey is studying unconventional continuous-type and, to a lesser extent, conventional oil and gas accumulations and the environmental impacts associated with their development. Continuous-type gas accumulations are generally characterized by low matrix permeabilities, large areal extents, and no distinct water contacts. This basin scale map shows the overall extent of these accumulations and the general land use types that may be impacted by their development. The Appalachian Basin has the longest history of oil and gas exploration and production in the United States. Since Drake's Titusville discovery well was drilled in 1859, oil and gas has been continuously produced in the basin. While there is still a great deal of oil and gas production, new field discoveries are rare and relatively small. For most of the second half of the 20th century the Appalachian basin has been considered a mature petroleum province because most of the large plays have already been discovered and developed. One exception to this trend is the Lower Silurian Clinton Sands and Medina Group Gas play which is being developed in New York, Pennsylvania, and Ohio. This continuous-type gas play has been expanding since the early 1970's (see inset maps). In the 1980's economic incentives such as large increases in wellhead prices further stimulated continuous-type gas resource development. Continuous-type gas plays can be large in areal extent and in thickness. 'Sweetspots' (areas of greater prodcution) are hard to predict and generally associated with better than average permeabilities, and enhanced by natural fracture systems. With an overall success rate often approaching 90%, drilling most of the play with closely spaced wells is often the best way to maximize gas recovery. Some positive economic characteristics associated with the development of these continuous-type accumulations are high success rates, low drilling and development costs, and low water production, which results in low water disposal costs. Large areas within the Appalachian basin with good potential for this type of gas accumulation remain to be tested. Positive environmental characteristics include, a clean energy source, low water production, and relatively low surface impact. Some negative characteristics associated with these continuous -type accumulations are low individual well production rates and small well drainage area. Negative environmental characteristics are primarily related to the dense well spacing used to develop the resource to its full potential. Often negative environmental impacts such as surface disturbance can be greatly reduced. The number of well sites can be decreased by using a single centrally located surface location and associated facilities for several directionally or horizonatally drilled wells. This also minimizes the transportation infrastructure (access roads and pipelines) required to maintain the wells and deliver the gas. Visual impacts can be reduced by selecting well locations visible only over short distances. While the prospective area is large, potential decreases basin- ward and toward the northeast and southwest. These areas are represented by the lower potential plays 6727, 6730, and 6731. The U.S. Geological Survey landuse and landcover data was derived from USGS 1:250,000 and 1:100,000 scale maps. This information was collected between the mid 1970s to mid 1980s. The land use and land cover data was mapped and coded using the Anderson classification system (Anderson, 1975) which is a hierarchical system of general (level 1) to more specific (level 2) characterization. Level 1 characterization was used for this map; the land use and land cover designations are displayed below in the Explanation. T
Issues in Energy Economics Led by Emerging Linkages between the Natural Gas and Power Sectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Platt, Jeremy B.
2007-09-15
Fuel prices in 2006 continued at record levels, with uranium continuing upward unabated and coal, SO{sub 2} emission allowances, and natural gas all softening. This softening did not continue for natural gas, however, whose prices rose, fell and rose again, first following weather influences and, by the second quarter of 2007, continuing at high levels without any support from fundamentals. This article reviews these trends and describes the remarkable increases in fuel expenses for power generation. By the end of 2005, natural gas claimed 55% of annual power sector fuel expenses, even though it was used for only 19% ofmore » electric generation. Although natural gas is enormously important to the power sector, the sector also is an important driver of the natural gas market-growing to over 28% of the market even as total use has declined. The article proceeds to discuss globalization, natural gas price risk, and technology developments. Forces of globalization are poised to affect the energy markets in new ways-new in not being only about oil. Of particular interest in the growth of intermodal traffic and its a little-understood impacts on rail traffic patterns and transportation costs, and expected rapidly expanding LNG imports toward the end of the decade. Two aspects of natural gas price risk are discussed: how understanding the use of gas in the power sector helps define price ceilings and floors for natural gas, and how the recent increase in the natural gas production after years of record drilling could alter the supply-demand balance for the better. The article cautions, however, that escalation in natural gas finding and development costs is countering the more positive developments that emerged during 2006. Regarding technology, the exploitation of unconventional natural gas was one highlight. So too was the queuing up of coal-fired power plants for the post-2010 period, a phenomenon that has come under great pressure with many consequences including increased pressures in the natural gas market. The most significant illustration of these forces was the early 2007 suspension of development plans by a large power company, well before the Supreme Court's ruling on CO{sub 2} as a tailpipe pollutant and President Bush's call for global goals on CO{sub 2} emissions.« less
40 CFR 1065.350 - H2O interference verification for CO2 NDIR analyzers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... verification as follows: (1) Start, operate, zero, and span the CO2 NDIR analyzer as you would before an.... (2) Create a humidified test gas by bubbling zero gas that meets the specifications in § 1065.750..., as close as possible to the inlet of the analyzer. For example, measure dewpoint, T dew, and absolute...
40 CFR 1065.350 - H2O interference verification for CO2 NDIR analyzers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... verification as follows: (1) Start, operate, zero, and span the CO2 NDIR analyzer as you would before an.... (2) Create a humidified test gas by bubbling zero gas that meets the specifications in § 1065.750..., as close as possible to the inlet of the analyzer. For example, measure dewpoint, T dew, and absolute...
40 CFR 1065.350 - H2O interference verification for CO2 NDIR analyzers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... verification as follows: (1) Start, operate, zero, and span the CO2 NDIR analyzer as you would before an.... (2) Create a humidified test gas by bubbling zero gas that meets the specifications in § 1065.750..., as close as possible to the inlet of the analyzer. For example, measure dewpoint, T dew, and absolute...
40 CFR 1065.350 - H2O interference verification for CO2 NDIR analyzers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... verification as follows: (1) Start, operate, zero, and span the CO2 NDIR analyzer as you would before an.... (2) Create a humidified test gas by bubbling zero gas that meets the specifications in § 1065.750..., as close as possible to the inlet of the analyzer. For example, measure dewpoint, T dew, and absolute...
40 CFR 1065.350 - H2O interference verification for CO2 NDIR analyzers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... verification as follows: (1) Start, operate, zero, and span the CO2 NDIR analyzer as you would before an.... (2) Create a humidified test gas by bubbling zero gas that meets the specifications in § 1065.750..., as close as possible to the inlet of the analyzer. For example, measure dewpoint, T dew, and absolute...
46 CFR 153.964 - Discharge by gas pressurization.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Discharge by gas pressurization. 153.964 Section 153.964 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Cargo Transfer...
46 CFR 153.964 - Discharge by gas pressurization.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Discharge by gas pressurization. 153.964 Section 153.964 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Cargo Transfer...
46 CFR 153.964 - Discharge by gas pressurization.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Discharge by gas pressurization. 153.964 Section 153.964 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Cargo Transfer...
46 CFR 153.964 - Discharge by gas pressurization.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Discharge by gas pressurization. 153.964 Section 153.964 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Cargo Transfer...
46 CFR 153.964 - Discharge by gas pressurization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Discharge by gas pressurization. 153.964 Section 153.964 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations Cargo Transfer...
A simple technique for continuous measurement of time-variable gas transfer in surface waters
Tobias, Craig R.; Bohlke, John Karl; Harvey, Judson W.; Busenberg, Eurybiades
2009-01-01
Mass balance models of dissolved gases in streams, lakes, and rivers serve as the basis for estimating wholeecosystem rates for various biogeochemical processes. Rates of gas exchange between water and the atmosphere are important and error-prone components of these models. Here we present a simple and efficient modification of the SF6 gas tracer approach that can be used concurrently while collecting other dissolved gas samples for dissolved gas mass balance studies in streams. It consists of continuously metering SF6-saturated water directly into the stream at a low rate of flow. This approach has advantages over pulse injection of aqueous solutions or bubbling large amounts of SF6 into the stream. By adding the SF6 as a saturated solution, we minimize the possibility that other dissolved gas measurements are affected by sparging and/or bubble injecta. Because the SF6 is added continuously we have a record of changing gas transfer velocity (GTV) that is contemporaneous with the sampling of other nonconservative ambient dissolved gases. Over a single diel period, a 30% variation in GTV was observed in a second-order stream (Sugar Creek, Indiana, USA). The changing GTV could be attributed in part to changes in temperature and windspeed that occurred on hourly to diel timescales.
Transition in the equilibrium distribution function of relativistic particles.
Mendoza, M; Araújo, N A M; Succi, S; Herrmann, H J
2012-01-01
We analyze a transition from single peaked to bimodal velocity distribution in a relativistic fluid under increasing temperature, in contrast with a non-relativistic gas, where only a monotonic broadening of the bell-shaped distribution is observed. Such transition results from the interplay between the raise in thermal energy and the constraint of maximum velocity imposed by the speed of light. We study the Bose-Einstein, the Fermi-Dirac, and the Maxwell-Jüttner distributions, and show that they all exhibit the same qualitative behavior. We characterize the nature of the transition in the framework of critical phenomena and show that it is either continuous or discontinuous, depending on the group velocity. We analyze the transition in one, two, and three dimensions, with special emphasis on twodimensions, for which a possible experiment in graphene, based on the measurement of the Johnson-Nyquist noise, is proposed.
Transition in the Equilibrium Distribution Function of Relativistic Particles
Mendoza, M.; Araújo, N. A. M.; Succi, S.; Herrmann, H. J.
2012-01-01
We analyze a transition from single peaked to bimodal velocity distribution in a relativistic fluid under increasing temperature, in contrast with a non-relativistic gas, where only a monotonic broadening of the bell-shaped distribution is observed. Such transition results from the interplay between the raise in thermal energy and the constraint of maximum velocity imposed by the speed of light. We study the Bose-Einstein, the Fermi-Dirac, and the Maxwell-Jüttner distributions, and show that they all exhibit the same qualitative behavior. We characterize the nature of the transition in the framework of critical phenomena and show that it is either continuous or discontinuous, depending on the group velocity. We analyze the transition in one, two, and three dimensions, with special emphasis on twodimensions, for which a possible experiment in graphene, based on the measurement of the Johnson-Nyquist noise, is proposed. PMID:22937220
NASA Astrophysics Data System (ADS)
Bogoev, Ivan; Helbig, Manuel; Sonnentag, Oliver
2015-04-01
A growing number of studies report systematic differences in CO2 flux estimates obtained with the two main types of gas analyzers: compared to eddy-covariance systems based on closed-path (CP) gas analyzers, systems with open-path (OP) gas analyzers systematically overestimate CO2 uptake during daytime periods with high positive sensible heat fluxes, while patterns for differences in nighttime CO2 exchange are less obvious. These biases have been shown to correlate with the sign and the magnitude of the sensible heat flux and to introduce large uncertainties when calculating annual CO2 budgets. In general, CP and OP gas analyzers commonly used to measure the CO2 density in the atmosphere operate on the principle of infrared light absorption approximated by Beer-Lambert's law. Non-dispersive interference-based optical filter elements are used to select spectral bands with strong attenuation of light transmission, characteristic to the gas of interest. The intensity of the light passing through the optical sensing path depends primarily on the amount of absorber gas in the measurement volume. Besides the density of the gas, barometric pressure and air temperature are additional factors affecting the strength and the half-width of the absorption lines. These so-called spectroscopic effects are accounted for by measuring barometric pressure and air temperature in the sensing path and scaling the light-intensity measurements before applying the calibration equation. This approach works well for CP gas analyzers with an intake tube that acts as a low-pass filter on fast air-temperature fluctuations. Low-frequency response temperature sensors in the measurement cell are therefore sufficient to account for spectroscopic temperature effects. In contrast, OP gas analyzers are exposed to high-frequency air-temperature fluctuations associated with the atmospheric surface-layer turbulent heat exchange. If not corrected adequately, these fast air-temperature variations can cause systematic errors in the CO2 density measurements. Under conditions of high positive or negative sensible heat flux, air-temperature fluctuations are correlated with fluctuations of the vertical wind component and can lead to significant biases in the CO2 flux estimates. This study demonstrates that sonically derived fast-response air temperature in the optical sensing path of an OP gas analyzer can replace the slow-response measurements from the temperature sensor as a scaling parameter in the calibration model to correct for these air temperature-induced spectroscopic effects. Our approach is evaluated by comparison between different OP and CP gas analyzer-based eddy-covariance systems in ecosystems with low CO2 uptake under a range of sensible heat flux regimes and varying meteorological parameters. We show that ignoring high-frequency spectroscopic effects can lead to false interpretations of net ecosystem CO2 exchange for specific site and environmental conditions.
NASA Astrophysics Data System (ADS)
Roy, J. W.; Smith, J. E.
2006-12-01
A number of mechanisms can lead to the presence of disconnected bubbles or ganglia of gas phase in groundwater. When associated with or near a DNAPL phase, the disconnected gas phase experiences mass transfer of dissolved gases including the volatile components of the DNAPL. The properties of the gas phase interface, such as interfacial tension and contact angle, can also be affected. This work addresses the behavior of spontaneous continual growth of initially trapped seed gas bubbles within DNAPL source zones. Three different experiments were performed in a 2-dimensional transparent flow cell 15 cm by 20 cm by 1.5 cm. In each case, a DNAPL pool was created within larger glass beads over smaller glass beads that served as a capillary barrier. The DNAPL consisted of either a 1:2 (v/v) tetrachloroethene (PCE) to benzene mixture, single component PCE, or single component TCE. The experiments effectively demonstrate spontaneous gas phase expansion and vertical advective mobilization of gas bubbles and ganglia above the DNAPL source zone. A cycle of gas phase growth and mobilization was facilitated by the presence of secondary seed bubbles left behind due to snap-off during vertical bubble (ganglion) mobilization. This gas phase growth process was relatively slow but continuous and could be expected to continue until the NAPL is completely dissolved. Some implications of the demonstrated behavior for water flow and mass transfer within and near the DNAPL source zone are highlighted.
Continuous CO2 gas monitoring to clarify natural pattern and artificial leakage signals
NASA Astrophysics Data System (ADS)
Joun, W.; Ha, S. W.; Joo, Y. J.; Lee, S. S.; Lee, K. K.
2017-12-01
Continuous CO2 gas monitoring at shallow aquifer is significant for early detection and immediate handling of an aquifer impacted by leaking CO2 gas from the sequestration reservoir. However, it is difficult to decide the origin of CO2 gas because detected CO2 includes not only leaked CO2 but also naturally emitted CO2. We performed CO2 injection and monitoring tests in a shallow aquifer. Before the injection of CO2 infused water, we have conducted continuous monitoring of multi-level soil CO2 gas concentration and physical parameters such as temperature, humidity, pressure, wind speed and direction, and precipitation. The monitoring data represented that CO2 gas concentrations in unsaturated soil zone borehole showed differences at depths and daily variation (360 to 6980 ppm volume). Based on the observed data at 5 m and 8 m depths, vertical flux of gas was calculated as 0.471 L/min (LPM) for inflow from 5 m to 8 m and 9.42E-2 LPM for outflow from 8 m to 5 m. The numerical and analytical models were used to calculate the vertical flux of gas and to compare with observations. The results showed that pressure-based modeling could not explain the rapid change of CO2 gas concentration in borehole. Acknowledgement Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2 Storage" from the KEITI (Project Number: 2014001810003)
Tennyson, Marilyn E.; Charpentier, Ronald R.; Klett, Timothy R.; Brownfield, Michael E.; Pitman, Janet K.; Gaswirth, Stephanie B.; Hawkins, Sarah J.; Lillis, Paul G.; Marra, Kristen R.; Mercier, Tracey J.; Leathers, Heidi M.; Schenk, Christopher J.; Whidden, Katherine J.
2015-10-06
Using a geology-based assessment methodology, the U.S. Geological Survey assessed mean volumes of 21 million barrels of oil (MMBO), 27 billion cubic feet of gas, and 1 million barrels of natural gas liquids in two assessment units (AUs) that may contain continuous oil resources. Mean volumes of oil for the individual assessment units are 14 MMBO in the Monterey Buttonwillow AU and 7 MMBO in the Monterey Maricopa AU.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Shenyang; Setyawan, Wahyu; Joshi, Vineet V.
Xe gas bubble superlattice formation is observed in irradiated uranium–10 wt% molybdenum (U10Mo) fuels. However, the thermodynamic properties of the bubbles (the relationship among bubble size, equilibrium Xe concentration, and bubble pressure) and the mechanisms of bubble growth and superlattice formation are not well known. In this work, molecular dynamics is used to study these properties and mechanisms. The results provide important inputs for quantitative mesoscale models of gas bubble evolution and fuel performance. In the molecular dynamics simulations, the embedded-atom method (EAM) potential of U10Mo-Xe (Smirnova et al. 2013) is employed. Initial gas bubbles with low Xe concentration aremore » generated in a U10Mo single crystal. Then Xe atom atoms are continuously added into the bubbles, and the evolution of pressure and dislocation emission around the bubbles is analyzed. The relationship between pressure, equilibrium Xe concentration, and radius of the bubbles is established. It was found that the gas bubble growth is accompanied by partial dislocation emission, which results in a star-shaped dislocation structure and an anisotropic stress field. The emitted partial dislocations have a Burgers vector along the <111> direction and a slip plane of (11-2). Dislocation loop punch-out was not observed. A tensile stress was found along <110> directions around the bubble, favoring the nucleation and formation of a face-centered cubic bubble superlattice in body-centered cubic U10Mo fuels.« less
USGS Methodology for Assessing Continuous Petroleum Resources
Charpentier, Ronald R.; Cook, Troy A.
2011-01-01
The U.S. Geological Survey (USGS) has developed a new quantitative methodology for assessing resources in continuous (unconventional) petroleum deposits. Continuous petroleum resources include shale gas, coalbed gas, and other oil and gas deposits in low-permeability ("tight") reservoirs. The methodology is based on an approach combining geologic understanding with well productivities. The methodology is probabilistic, with both input and output variables as probability distributions, and uses Monte Carlo simulation to calculate the estimates. The new methodology is an improvement of previous USGS methodologies in that it better accommodates the uncertainties in undrilled or minimally drilled deposits that must be assessed using analogs. The publication is a collection of PowerPoint slides with accompanying comments.
Optoelectronics sensors of hydrocarbons based on NDIR technique
NASA Astrophysics Data System (ADS)
Prokopiuk, Artur
2017-08-01
Saturated hydrocarbons are mainly nontoxic, but as extremely flammable gases forming explosive mixtures with air. The Lower Explosive Level (LEL) for methane is 4.4%, which is very dangerous in the mining industry. Methane is also an asphyxiant gas causing coma or death. Therefore, continuous monitoring of the hydrocarbons concentration is very important. Optoelectronic methods are very attractive for this application, especially nondispersive infrared (NDIR) technique. It enables a direct, fast, and selective measurement of different gas concentrations. NDIR sensors have many advantages, which make them very promising for use as hydrocarbon detectors. Despite a lot of benefits, common used NDIR sensors have some disadvantages. They need periodic calibration and have limited detection range, from 100ppm. These parameters can be improved thanks to modernization detection scheme and use of newest IR sources and detectors. During Analyses selected IR sources and detectors were taken into account. Absorption spectra of analyzed hyrdrocarbons were studied to minimize impact interfering gases like carbon dioxide and water.
Amaral, Simone Simões; de Carvalho, João Andrade; Costa, Maria Angélica Martins; Soares Neto, Turíbio Gomes; Dellani, Rafael; Leite, Luiz Henrique Scavacini
2014-07-01
Two different types of typical Brazilian forest biomass were burned in the laboratory in order to compare their combustion characteristics and pollutant emissions. Approximately 2 kg of Amazon biomass (hardwood) and 2 kg of Araucaria biomass (softwood) were burned. Gaseous emissions of CO2, CO, and NOx and particulate matter smaller than 2.5 μm (PM2.5) were evaluated in the flaming and smoldering combustion phases. Temperature, burn rate, modified combustion efficiency, emissions factor, and particle diameter and concentration were studied. A continuous analyzer was used to quantify gas concentrations. A DataRam4 and a Cascade Impactor were used to sample PM2.5. Araucaria biomass (softwood) had a lignin content of 34.9%, higher than the 23.3% of the Amazon biomass (hardwood). CO2 and CO emissions factors seem to be influenced by lignin content. Maximum concentrations of CO2, NOx and PM2.5 were observed in the flaming phase. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cinematica del gas ionizado y perfiles de luminosidad de las Galaxias Porotos Verdes
NASA Astrophysics Data System (ADS)
Diaz, R. J.; Aguero, M.; Schirmer, M.; Holheim, K.; Levenson, N.; Winge, C.
We present preliminary spectroscopic results of a sample of green bean galaxies (GBG); known to show ultra-luminous; galaxy-wide; narrow-line regions. We analyze Gemini GMOS-S;N spectra of a sample of 12 GBG in order to obtain emission line ratios; gas kinematics and luminosity profiles in some continuous bands. We report here new results that confirm that the 5008 emission extends from 5 to 17 kpc; in all cases scales similar or larger than the stellar continuums at the spectra. In the extreme case of J145533.6+044643 the emission reaches a diameter of 17.51.6kpc. We find that the continuum half light radii extend from 3 to 7 kpc; the largest scale radius at shortest wavelengths; which is consistent with the scale lengths of large spiral galaxies or merging systems. Another new result is that the spatial variation of the continuum color profiles indicate the presence of extinction and possibly star formation. FULL TEXT IN SPANISH
Ciaffoni, Luca; O'Neill, David P; Couper, John H; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A
2016-08-01
There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible.
Park, Byeoung-Soo; Lee, Kwang-Geun; Shibamoto, Takayuki; Lee, Sung-Eun; Takeoka, Gary R
2003-01-01
Volatiles were isolated from the dried inner bark of Tabebuia impetiginosa using steam distillation under reduced pressure followed by continuous liquid-liquid extraction. The extract was analyzed by gas chromatography and gas chromatography-mass spectrometry. The major volatile constituents of T. impetiginosa were 4-methoxybenzaldehyde (52.84 microg/g), 4-methoxyphenol (38.91 microg/g), 5-allyl-1,2,3-trimethoxybenzene (elemicin; 34.15 microg/g), 1-methoxy-4-(1E)-1-propenylbenzene (trans-anethole; 33.75 microg/g), and 4-methoxybenzyl alcohol (30.29 microg/g). The antioxidant activity of the volatiles was evaluated using two different assays. The extract exhibited a potent inhibitory effect on the formation of conjugated diene hydroperoxides (from methyl linoleate) at a concentration of 1000 microg/mL. The extract also inhibited the oxidation of hexanal for 40 days at a level of 5 microg/mL. The antioxidative activity of T. impetiginosa volatiles was comparable with that of the well-known antioxidants, alpha-tocopherol, and butylated hydroxytoluene.
Electrospray Modifications for Advancing Mass Spectrometric Analysis
Meher, Anil Kumar; Chen, Yu-Chie
2017-01-01
Generation of analyte ions in gas phase is a primary requirement for mass spectrometric analysis. One of the ionization techniques that can be used to generate gas phase ions is electrospray ionization (ESI). ESI is a soft ionization method that can be used to analyze analytes ranging from small organics to large biomolecules. Numerous ionization techniques derived from ESI have been reported in the past two decades. These ion sources are aimed to achieve simplicity and ease of operation. Many of these ionization methods allow the flexibility for elimination or minimization of sample preparation steps prior to mass spectrometric analysis. Such ion sources have opened up new possibilities for taking scientific challenges, which might be limited by the conventional ESI technique. Thus, the number of ESI variants continues to increase. This review provides an overview of ionization techniques based on the use of electrospray reported in recent years. Also, a brief discussion on the instrumentation, underlying processes, and selected applications is also presented. PMID:28573082
Ciaffoni, Luca; O’Neill, David P.; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Robbins, Peter A.
2016-01-01
There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible. PMID:27532048
Ampicillin Nanoparticles Production via Supercritical CO2 Gas Antisolvent Process.
Esfandiari, Nadia; Ghoreishi, Seyyed M
2015-12-01
The micronization of ampicillin via supercritical gas antisolvent (GAS) process was studied. The particle size distribution was significantly controlled with effective GAS variables such as initial solute concentration, temperature, pressure, and antisolvent addition rate. The effect of each variable in three levels was investigated. The precipitated particles were analyzed with scanning electron microscopy (SEM) and Zetasizer Nano ZS. The results indicated that decreasing the temperature and initial solute concentration while increasing the antisolvent rate and pressure led to a decrease in ampicillin particle size. The mean particle size of ampicillin was obtained in the range of 220-430 nm by varying the GAS effective variables. The purity of GAS-synthesized ampicillin nanoparticles was analyzed in contrast to unprocessed ampicillin by FTIR and HPLC. The results indicated that the structure of the ampicillin nanoparticles remained unchanged during the GAS process.
10 CFR 590.101 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS General Provisions § 590.101 Purpose and scope... to obtain authorizations from DOE to import or export natural gas under the Natural Gas Act and by...
10 CFR 590.101 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS General Provisions § 590.101 Purpose and scope... to obtain authorizations from DOE to import or export natural gas under the Natural Gas Act and by...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS General § 153.1 Applicability. This part applies to the... bulk liquid, liquefied gas, or compressed gas cargo that is not— (1) Listed in Table 1 of this part; (2...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS General § 153.1 Applicability. This part applies to the... bulk liquid, liquefied gas, or compressed gas cargo that is not— (1) Listed in Table 1 of this part; (2...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS General § 153.1 Applicability. This part applies to the... bulk liquid, liquefied gas, or compressed gas cargo that is not— (1) Listed in Table 1 of this part; (2...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS General § 153.1 Applicability. This part applies to the... bulk liquid, liquefied gas, or compressed gas cargo that is not— (1) Listed in Table 1 of this part; (2...
Methylation of 2-Naphthol Using Dimethyl Carbonate under Continuous-Flow Gas-Phase Conditions
ERIC Educational Resources Information Center
Tundo, Pietro; Rosamilia, Anthony E.; Arico, Fabio
2010-01-01
This experiment investigates the methylation of 2-naphthol with dimethyl carbonate. The volatility of the substrates, products, and co-products allows the reaction to be performed using a continuous-flow gas-phase setup at ambient pressure. The reaction uses catalytic quantities of base, achieves high conversion, produces little waste, and…
Klett, Timothy R.; Schenk, Christopher J.; Brownfield, Michael E.; Leathers-Miller, Heidi M.; Mercier, Tracey J.; Pitman, Janet K.; Tennyson, Marilyn E.
2016-11-10
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean continuous resources of 12 billion barrels of oil and 75 trillion cubic feet of gas in the Bazhenov Formation of the West Siberian Basin Province, Russia.
40 CFR Table Hh-4 to Subpart Hh of... - Landfill Methane Oxidation Fractions
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas sent off-site). If a single monitoring location is used to monitor volumetric flow and CH4... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Landfill Methane Oxidation Fractions... (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Municipal Solid Waste Landfills Pt...
Schenk, Christopher J.; Mercier, Tracey J.; Tennyson, Marilyn E.; Woodall, Cheryl A.; Finn, Thomas M.; Pitman, Janet K.; Gaswirth, Stephanie B.; Marra, Kristen R.; Le, Phuong A.; Klett, Timothy R.; Leathers-Miller, Heidi M.
2018-04-13
Using a geology-based assessment methodology, the U.S. Geological Survey estimated mean undiscovered, technically recoverable resources of 198 billion cubic feet of continuous gas in the Phosphoria Formation of the Wyoming Thrust Belt Province, Wyoming, Idaho, and Utah.
40 CFR Table A-5 to Subpart A of... - Supplier Category List for § 98.2(a)(4)
Code of Federal Regulations, 2011 CFR
2011-07-01
... liquids suppliers (subpart NN): (A) All fractionators. (B) Local natural gas distribution companies that... (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING General Provision Pt. 98, Subpt. A... a Applicable in 2010 and Future Years Coal-to-liquids suppliers (subpart LL): (A) All producers of...
NASA Technical Reports Server (NTRS)
Rothermel, Jeffry; Chambers, Diana M.; Jarzembski, Maurice A.; Srivastava, Vandana; Bowdle, David A.; Jones, William D.
1996-01-01
Two continuous-wave(CW)focused C02 Doppler lidars (9.1 and 10.6 micrometers) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic and spectrum analyzer and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is approximately 3 x 10(exp -12)/m/sr at 9.1 micrometers and approximately 9 x 10(exp -12)/m/sr at 10.6 micrometers. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6 micrometer lidar intercomparisons were made. Measurements at 9.1 micrometers, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope C-12 O(2)-18 gas.
[Poisoning by exhaust gas of the imperfect combustion of natural gas: 22 cases study].
Dong, Li-Min; Zhao, Hai; Zhang, Ming-Chang; He, Meng
2014-10-01
To analyze the case characteristics of poisoning by exhaust gas of the imperfect combustion of natural gas and provide references for forensic identification and prevention of such accidents. Twenty-two cases of poisoning by exhaust gas of the imperfect combustion of natural gas in Minhang District during 2004 to 2013 were collected. Some aspects such as general conditions of deaths, incidence time, weather, field investigation, and autopsy were retrospectively analyzed. In the 22 cases, there were 15 males and 16 females. The age range was between 2 and 82 years old. The major occurring time was in January or February (8 cases in each) and the cases almost occurred in small area room (21 cases). There was wide crack next to the exhaust port when the gas water heater was been used in all cases. There are more prone to occurrence of exhaust gas poisoning of imperfect combustion of natural gas in small area room with a ventilation window near the exhaust port of gas water heated. It shows that the scene of combustion exhaust gas poisoning should be more concerned in the cold season.
NASA Astrophysics Data System (ADS)
Bellefleur, G.; Riedel, M.; Brent, T.
2005-12-01
Gas hydrate deposits in arctic environment generally lack the BSR signature diagnostic of their presence in marine seismic data. The absence of the BSR signature complicates the estimation of the resources within or below the permafrost and the determination of their potential impact on future energy supplies, geohazard and climate change. We present results from a detailed seismic characterization of three gas hydrate horizons (A, B and C) intersected below the permafrost in five wells of the Mallik gas hydrate field located in the Mackenzie delta (Northwest Territories, Canada). The detailed seismic characterization included attribute analyses, synthetic modeling and acoustic impedance inversion and allowed estimation of the lateral continuity of the three horizons in the vicinity of the wells. Vertical Seismic Profiling (VSP) data, 3D and 2D industry seismic data and the 5L/2L-38 geophysical logs (density, P-wave sonic velocity) were used for this study. Synthetic modeling using the sonic and density logs reveals that the base of the lower gas hydrate horizons B and C can be identified on the industry 3D and 2D seismic sections as prominent isolated reflections. The uppermost gas hydrate occurrence (horizon A) and potentially other additional smaller-scale layers are identified only on the higher-resolution VSP data. The 3D industry seismic data set processed to preserve the relative true-amplitudes was used for attribute calculations and acoustic impedance inversion. The attribute maps defined areas of continuous reflectivity for horizons B and C and structural features disrupting them. Results from impedance inversion indicate that such continuous reflectivity around the wells is most likely attributable to gas hydrates. The middle gas hydrate occurrence (horizon B) covers an area of approximately 25 000m2. Horizon C, which marks the base of gas hydrate occurrence zone, extends over a larger area of approximately 120 000m2.
,
2015-10-20
From 2000 to 2011, the U.S. Geological Survey conducted 139 quantitative assessments of continuous (unconventional) oil and gas accumulations within the United States. This report documents those assessments more fully than previously done by providing detailed documentation of both the assessment input and output. This report also compiles the data into spreadsheet tables that can be more readily used to provide analogs for future assessments, especially for hypothetical continuous accumulations.
Nonuniform dependence on initial data for compressible gas dynamics: The periodic Cauchy problem
NASA Astrophysics Data System (ADS)
Keyfitz, B. L.; Tığlay, F.
2017-11-01
We start with the classic result that the Cauchy problem for ideal compressible gas dynamics is locally well posed in time in the sense of Hadamard; there is a unique solution that depends continuously on initial data in Sobolev space Hs for s > d / 2 + 1 where d is the space dimension. We prove that the data to solution map for periodic data in two dimensions although continuous is not uniformly continuous.
NASA Astrophysics Data System (ADS)
Kollonige, D. E.; Thompson, A. M.; Nichols, M.; Fasnacht, Z.; Martins, D. K.; Dickerson, R. R.
2014-12-01
The increase in the natural gas component of the energy sector has led many state and local municipalities to begin regulation of emissions from the oil and natural gas operators with air quality (AQ) as a concern. "Top-down" measurements of trace gases in the air above wells complement "bottom-up" inventories, used by EPA and AQ stakeholders, through a more accurate depiction of regional variability of methane and other species near and downwind of oil and gas operations. Satellite observations of methane, nitrogen dioxide, formaldehyde, ozone, and other carbon gases enhance the spatial and temporal coverage of the data needed to demonstrate any long-term impacts from shale gas development. As part of a NASA AQAST (Air Quality Applied Sciences Team) project, we are evaluating satellite measurements of trace gases in regions with oil and gas operations for their application as a "top-down" constraint. For validation of the satellite instruments' sensitivities to emitted gases, we focus on regions where the DISCOVER-AQ (Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality) campaign deployed with ground and aircraft measurements, including, Maryland (2011), California and Texas (2013), and Colorado (2014). We compare vertical distributions of methane and volatile organic compounds (VOCs) nearby and downwind of oil and gas wells to locate any regional differences during the campaign time periods. This allows for better characterization of the satellite observations and their limitations for application in air quality studies in similar environments. Taking advantage of current EOS-era satellites' data records, we also analyze methane anomalies and gas correlations in the free troposphere from 2005 to present to identify trends for basins with oil and gas extraction sites and their influence on background concentrations downwind of wells. In most regions with oil and gas activity, we see continually increasing methane concentrations and about a 5-10 percent enhancement above background tropospheric concentrations. With this ongoing effort, we aim to demonstrate the benefits of satellite-derived "top-down" constraints for emissions estimates associated with oil and natural gas operations.
A portable Fourier transform infrared gas analyzer with a photoacoustic detector performed reliably during pollution prevention research at two industrial facilities. It exhibited good agreement (within approximately 6%) with other analytical instruments (dispersive infrared and ...
[Gas analyzer "HelicoSense" as a new device for diagnosis of the Helicobacter infection].
Kozlov, A V; Evstratova, Iu S; Novikova, V P; Tkachenko, E I; Khochinskaia, O Iu
2006-01-01
According to recommendations of the European Health Committee, noninvasive methods should be preferred for diagnosis of Helicobacter pylori (HP) infection in children. Equipment and reagents for respiration diagnostic tests available from foreign manufacturers have rather high cost, which hinders their use in domestic medical institutions. A new noninvasive electrochemical technique for HP detection is based on the use of HelicoSense gas analyzer. 150 patients (100 children 6-17 years old and 50 adults 18-78 years old) participated in mulicenter testing of the developed technique. Chronic gastritis was previously diagnosed by endoscopic and morphological examination in all patients. HP status was studied using bacteriological, serological, and cytological methods, as well as the Helpil test. The obtained results were compared to the results of examination with HelicoSense gas analyzer. Our study showed that HelicoSense gas analyzer provides easy use, patient's safety, and possibility of rapid testing. Its application does not require specially trained medical personnel. The device provides high specificity (86.7%) and high sensitivity (93.7%).