Brown, Rebecca; Johnstone, Edward D; Heazell, Alexander E P
2016-01-01
Continuous longer-term fetal monitoring has been proposed to address limitations of current technologies in the detection of fetal compromise. We aimed to assess professionals' views regarding current fetal-monitoring techniques and proposed longer-term continuous fetal monitoring. A questionnaire was designed and validated to assess obstetricians' and midwives' use of current fetal-monitoring techniques and their views towards continuous monitoring. 125 of 173 received responses (72% obstetricians, 28% midwives) were analysed. Professionals had the strongest views about supporting evidence for the most commonly employed fetal-monitoring techniques (maternal awareness of fetal movements, ultrasound assessment of fetal growth and umbilical artery Doppler). 45.1% of professionals agreed that a continuous monitoring device would be beneficial (versus 28.7% who disagreed); this perceived benefit was not influenced by professionals' views regarding current techniques or professional background. Professionals have limited experience of continuous fetal monitoring, but most respondents believed that it would increase maternal anxiety (64.3%) and would have concerns with its use in clinical practice (81.7%). Continuous fetal monitoring would be acceptable to the majority of professionals. However, development of these technologies must be accompanied by extended examination of professionals' and women's views to determine barriers to its introduction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Continuous Seismic Threshold Monitoring
1992-05-31
Continuous threshold monitoring is a technique for using a seismic network to monitor a geographical area continuously in time. The method provides...area. Two approaches are presented. Site-specific monitoring: By focusing a seismic network on a specific target site, continuous threshold monitoring...recorded events at the site. We define the threshold trace for the network as the continuous time trace of computed upper magnitude limits of seismic
Lens-free shadow image based high-throughput continuous cell monitoring technique.
Jin, Geonsoo; Yoo, In-Hwa; Pack, Seung Pil; Yang, Ji-Woon; Ha, Un-Hwan; Paek, Se-Hwan; Seo, Sungkyu
2012-01-01
A high-throughput continuous cell monitoring technique which does not require any labeling reagents or destruction of the specimen is demonstrated. More than 6000 human alveolar epithelial A549 cells are monitored for up to 72 h simultaneously and continuously with a single digital image within a cost and space effective lens-free shadow imaging platform. In an experiment performed within a custom built incubator integrated with the lens-free shadow imaging platform, the cell nucleus division process could be successfully characterized by calculating the signal-to-noise ratios (SNRs) and the shadow diameters (SDs) of the cell shadow patterns. The versatile nature of this platform also enabled a single cell viability test followed by live cell counting. This study firstly shows that the lens-free shadow imaging technique can provide a continuous cell monitoring without any staining/labeling reagent and destruction of the specimen. This high-throughput continuous cell monitoring technique based on lens-free shadow imaging may be widely utilized as a compact, low-cost, and high-throughput cell monitoring tool in the fields of drug and food screening or cell proliferation and viability testing. Copyright © 2012 Elsevier B.V. All rights reserved.
A nondestructive method for continuously monitoring plant growth.
Schwartzkopf, S H
1985-06-01
In the past, plant growth generally has been measured using destructive methods. This paper describes a nondestructive technique for continuously monitoring plant growth. The technique provides a means of directly and accurately measuring plant growth over both short and long time intervals. Application of this technique to the direct measurement of plant growth rates is illustrated using corn (Zea mays L.) as an example.
2000-02-01
HIDS] Program: Power Drive Train Crack Detection Diagnostics and Prognostics ife Usage Monitoring and Damage Tolerance; Techniques, Methodologies, and...and Prognostics , Life Usage Monitoring , and Damage Tolerance; Techniques, Methodologies, and Experiences Andrew Hess Harrison Chin William Hardman...continuing program and deployed engine monitoring systems in fixed to evaluate helicopter diagnostic, prognostic , and wing aircraft, notably on the A
NASA Astrophysics Data System (ADS)
Cordes, A.; Pollig, D.; Leonhardt, S.
2010-04-01
For monitoring the health status of individuals, proper monitoring of ventilation is desirable. Therefore, a continuous measurement technique is an advantage for many patients since it allows personal home care scenarios. As an example, monitoring of elderly people at home could enable them to live in their familiar environment on their own with the safety of a continuous monitoring. Therefore, a measurement technique without the restriction of mobility is required. Since it is possible to monitor ventilation with magnetic impedance measurements without conductive contact, this technique is well suited for the mentioned scenario. Integrated in a chair, a person's health state could be monitored in many situations, e.g. during meals, while watching TV or reading a book. In this paper, we compare different positions of coil arrays for a magnetic impedance measurement system integrated in a chair in order to monitor ventilation continuously. For limiting the costs and technical complexity of the magnetic impedance measurement system, we have a focus on coil configurations with one RF channel. To limit the needed space and thickness of the array in the backrest, planar gradiometer coil setups are investigated. All measurements will be performed with a new developed portable magnetic impedance measurement system and a standard office chair.
Continuous EEG monitoring in the intensive care unit.
Scheuer, Mark L
2002-01-01
Continuous EEG (CEEG) monitoring allows uninterrupted assessment of cerebral cortical activity with good spatial resolution and excellent temporal resolution. Thus, this procedure provides a means of constantly assessing brain function in critically ill obtunded and comatose patients. Recent advances in digital EEG acquisition, storage, quantitative analysis, and transmission have made CEEG monitoring in the intensive care unit (ICU) technically feasible and useful. This article summarizes the indications and methodology of CEEG monitoring in the ICU, and discusses the role of some quantitative EEG analysis techniques in near real-time remote observation of CEEG recordings. Clinical examples of CEEG use, including monitoring of status epilepticus, assessment of ongoing therapy for treatment of seizures in critically ill patients, and monitoring for cerebral ischemia, are presented. Areas requiring further development of CEEG monitoring techniques and indications are discussed.
Phase-shift focus monitoring techniques
NASA Astrophysics Data System (ADS)
McQuillan, Matthew; Roberts, Bill
2006-03-01
Depth of focus (DOF) has become a victim of its mathematical relationship with Numerical Aperture (NA). While NA is being increased towards one to maximize scanner resolution capabilities, DOF is being minimized because of its inverse relationship with NA. Moore's law continues to drive the semiconductor industry towards smaller and smaller devices the need for high NA to resolve these shrinking devices will continue to consume the usable depth of focus (UDOF). Due to the shrinking UDOF a demand has been created for a feature or technology that will give engineers the capability to monitor scanner focus. Developing and implementation of various focus monitoring techniques have been used to prevent undetected tool focus excursions. Two overlay techniques to monitor ArF Scanner focus have been evaluated; our evaluation results will be presented here.
Fault Detection and Safety in Closed-Loop Artificial Pancreas Systems
2014-01-01
Continuous subcutaneous insulin infusion pumps and continuous glucose monitors enable individuals with type 1 diabetes to achieve tighter blood glucose control and are critical components in a closed-loop artificial pancreas. Insulin infusion sets can fail and continuous glucose monitor sensor signals can suffer from a variety of anomalies, including signal dropout and pressure-induced sensor attenuations. In addition to hardware-based failures, software and human-induced errors can cause safety-related problems. Techniques for fault detection, safety analyses, and remote monitoring techniques that have been applied in other industries and applications, such as chemical process plants and commercial aircraft, are discussed and placed in the context of a closed-loop artificial pancreas. PMID:25049365
CONTINUOUS PERFORMANCE MONITORING TECHNIQUES FOR HAZARDOUS WASTE INCINERATORS
The report describes a study to determine the feasibility of utilizing realtime continuous exhaust measurements of combustion intermediates as a way to monitor incinerator performance. The key issue was to determine if a direct correlation exists between destruction efficiency (D...
U.S. Geological Survey continuous monitoring workshop—Workshop summary report
Sullivan, Daniel J.; Joiner, John K.; Caslow, Kerry A.; Landers, Mark N.; Pellerin, Brian A.; Rasmussen, Patrick P.; Sheets, Rodney A.
2018-04-20
Executive SummaryThe collection of high-frequency (in other words, “continuous”) water data has been made easier over the years because of advances in technologies to measure, transmit, store, and query large, temporally dense datasets. Commercially available, in-situ sensors and data-collection platforms—together with new techniques for data analysis—provide an opportunity to monitor water quantity and quality at time scales during which meaningful changes occur. The U.S. Geological Survey (USGS) Continuous Monitoring Workshop was held to build stronger collaboration within the Water Mission Area on the collection, interpretation, and application of continuous monitoring data; share technical approaches for the collection and management of continuous data that improves consistency and efficiency across the USGS; and explore techniques and tools for the interpretation of continuous monitoring data, which increases the value to cooperators and the public. The workshop was organized into three major themes: Collecting Continuous Data, Understanding and Using Continuous Data, and Observing and Delivering Continuous Data in the Future. Presentations each day covered a variety of related topics, with a special session at the end of each day designed to bring discussion and problem solving to the forefront.The workshop brought together more than 70 USGS scientists and managers from across the Water Mission Area and Water Science Centers. Tools to manage, assure, control quality, and explore large streams of continuous water data are being developed by the USGS and other organizations and will be critical to making full use of these high-frequency data for research and monitoring. Disseminating continuous monitoring data and findings relevant to critical cooperator and societal issues is central to advancing the USGS networks and mission. Several important outcomes emerged from the presentations and breakout sessions.
Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study
NASA Astrophysics Data System (ADS)
Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.
2002-08-01
Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.
HANDBOOK: CONTINUOUS EMISSION MONITORING SYSTEMS FOR NON-CRITERIA POLLUTANTS
This Handbook provides a description of the methods used to continuously monitor non-criteria pollutants emitted from stationary sources. The Handbook contains a review of current regulatory programs, the state-of-the-art sampling system design, analytical techniques, and the use...
L.R. Ahuja; S. A. El-Swaify
1979-01-01
Continuous monitoring of soil-water pressures, rainfall and runoff under natural conditions was tested as a technique for determining soil hydrologic characteristics of a remote forest watershed plot. A completely battery-powered (and thus portable) pressure transducer–scanner–recorder system was assembled for monitoring of soil-water pressures in...
Process monitoring and visualization solutions for hot-melt extrusion: a review.
Saerens, Lien; Vervaet, Chris; Remon, Jean Paul; De Beer, Thomas
2014-02-01
Hot-melt extrusion (HME) is applied as a continuous pharmaceutical manufacturing process for the production of a variety of dosage forms and formulations. To ensure the continuity of this process, the quality of the extrudates must be assessed continuously during manufacturing. The objective of this review is to provide an overview and evaluation of the available process analytical techniques which can be applied in hot-melt extrusion. Pharmaceutical extruders are equipped with traditional (univariate) process monitoring tools, observing barrel and die temperatures, throughput, screw speed, torque, drive amperage, melt pressure and melt temperature. The relevance of several spectroscopic process analytical techniques for monitoring and control of pharmaceutical HME has been explored recently. Nevertheless, many other sensors visualizing HME and measuring diverse critical product and process parameters with potential use in pharmaceutical extrusion are available, and were thoroughly studied in polymer extrusion. The implementation of process analytical tools in HME serves two purposes: (1) improving process understanding by monitoring and visualizing the material behaviour and (2) monitoring and analysing critical product and process parameters for process control, allowing to maintain a desired process state and guaranteeing the quality of the end product. This review is the first to provide an evaluation of the process analytical tools applied for pharmaceutical HME monitoring and control, and discusses techniques that have been used in polymer extrusion having potential for monitoring and control of pharmaceutical HME. © 2013 Royal Pharmaceutical Society.
Monitoring for neuroprotection. New technologies for the new millennium
NASA Technical Reports Server (NTRS)
Andrews, R. J.
2001-01-01
Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.
Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources
NASA Astrophysics Data System (ADS)
Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai
2018-01-01
Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.
Vasudevan, Srivathsan; Chen, George C K; Ahluwalia, Balpreet Singh
2008-12-01
Photothermal response (PTR) is an established pump and probe technique for real-time sensing of biological assays. Continuous and selective PTR monitoring is difficult owing to the Brownian motion changing the relative position of the target with respect to the beams. Integration of laser trapping with PTR is proposed as a solution. The proposed method is verified on red polystyrene microparticles. PTR is continuously monitored for 30 min. Results show that the mean relaxation time variation of the acquired signals is less than 5%. The proposed method is then applied to human red blood cells for continuous and selective PTR.
A continuous plutonium aerosol monitor for use in high radon environments.
Li, HuiBin; Jia, MingYan; Li, GuoShen; Wang, YinDong
2012-01-01
Radon concentration is very high in underground basements and other facilities. Radon concentration in a nuclear facility locates in the granite tunnel can be as high as 10(4) Bq m(-3) in summer. Monitoring plutonium aerosol in this circumstance is seriously interfered by radon daughters. In order to solve this problem, a new continuous aerosol monitor that can monitor very low plutonium aerosol concentration in high radon background was developed. Several techniques were used to reduce interference of radon daughters, and the minimum detectable concentrations in various radon concentrations were measured.
Remote personal health monitoring with radio waves
NASA Astrophysics Data System (ADS)
Nguyen, Andrew
2008-03-01
We present several techniques utilizing radio-frequency identification (RFID) technology for personal health monitoring. One technique involves using RFID sensors external to the human body, while another technique uses both internal and external RFID sensors. Simultaneous monitoring of many patients in a hospital setting can also be done using networks of RFID sensors. All the monitoring are done wirelessly, either continuously or periodically in any interval, in which the sensors collect information on human parts such as the lungs or heart and transmit this information to a router, PC or PDA device connected to the internet, from which patient's condition can be diagnosed and viewed by authorized medical professionals in remote locations. Instantaneous information allows medical professionals to intervene properly and timely to prevent possible catastrophic effects to patients. The continuously monitored information provides medical professionals more complete and long-term studies of patients. All of these result in not only enhancement of the health treatment quality but also significant reduction of medical expenditure. These techniques demonstrate that health monitoring of patients can be done wirelessly at any time and any place without interfering with the patients' normal activities. Implementing the RFID technology would not only help reduce the enormous and significantly growing medical costs in the U.S.A., but also help improve the health treatment capability as well as enhance the understanding of long-term personal health and illness.
Hemodynamic monitoring in the critically ill.
Voga, G
1995-06-01
Monitoring of vital functions is one of the most important and essential tools in the management of critically ill patients in the ICU. Today it is possible to detect and analyze a great variety of physiological signals by various noninvasive and invasive techniques. An intensivist should be able to select and perform the most appropriate monitoring method for the individual patient considering risk-benefit ratio of the particular monitoring technique and the need for immediate therapy, specific diagnosis, continuous monitoring and evaluation of morphology should be included. Despite rapid development of noninvasive monitoring techniques, invasive hemodynamic monitoring in still one of the most basic ICU procedures. It enables monitoring of pressures, flow and saturation, pressures in the systemic and pulmonary circulation, estimation of cardiac performance and judgment of the adequacy of the cardiocirculatory system. Carefully and correctly obtained information are basis for proper hemodynamic assessment which usually effects the therapeutic decisions.
Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz
2015-04-01
Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.
The study of insect blood-feeding behaviour. 2. Recording techniques and the use of flow charts.
Smith, J J; Friend, W G
1987-01-01
This paper continues a discussion of approaches and methodologies we have used in our studies of feeding in haematophagous insects. Described are techniques for directly monitoring behaviour: electrical recording of feeding behaviour via resistance changes in the food canal, optical methods for monitoring mouthpart activity, and a computer technique for behavioural event recording. Also described is the use of "flow charts" or "decision diagrams" to model interrelated sequences of behaviours.
NASA Astrophysics Data System (ADS)
Jacobson, Gloria; Rella, Chris; Farinas, Alejandro
2014-05-01
Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits of Signal Averaging in Atmospheric Trace-Gas Monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS)," Applied Physics, B57, pp 131-139, April 1993
Commercialization Issues For Catheter-Based Electrochemical Sensors
NASA Astrophysics Data System (ADS)
Nikolchev, Julian; Gaisford, Scott
1989-08-01
The need for continuous monitoring of key clinical parameters in hospitals is well recognized. Figure 1 shows typical time constants for blood gases, ions and enzymes in response to acute ventilatory changes and interventions. Although it can be seen that relatively low rates of data collection are necessary for many medical measurements, it is also clear that intermittent measurement of P02, PCO2 and pH are not sufficient to provide safe and effective management of the patient. Very frequent or continuous monitoring is often essential. This figure also shows why the emphasis of a large number of research efforts in this country and in Europe and Japan have as their goal the development of continuous blood gas sensors, i.e., sensors that continuously monitor blood pH, partial pressure of oxygen and partial pressure of carbon dioxide. These are three (3) of the most frequent parameters measured in hospitals and the ones having the shortest time constant. Considering that in the United States alone close to 25 million blood gas samples per year are taken from patients, the potential market for continuous monitoring sensors is enormous. The emergence of microelectronics and microfabrication technologies over the past 30 years are now pointing to a possible resolution of the well recognized need for real time monitoring of critically ill patients through catheter-based sensors. Although physicians will always prefer non-invasive monitoring techniques, there are a number of parameters that presently can only be monitored by invasive method. The emerging ability to miniaturize chemical sensors using silicon microfabrication or fiber-optic techniques offer an excellent opportunity to solve this need. In fact, the development of in vivo biomedical sensors with satisfactory performance characteristics has long been considered the ultimate application of these emerging technologies.
Decoupled tracking and thermal monitoring of non-stationary targets.
Tan, Kok Kiong; Zhang, Yi; Huang, Sunan; Wong, Yoke San; Lee, Tong Heng
2009-10-01
Fault diagnosis and predictive maintenance address pertinent economic issues relating to production systems as an efficient technique can continuously monitor key health parameters and trigger alerts when critical changes in these variables are detected, before they lead to system failures and production shutdowns. In this paper, we present a decoupled tracking and thermal monitoring system which can be used on non-stationary targets of closed systems such as machine tools. There are three main contributions from the paper. First, a vision component is developed to track moving targets under a monitor. Image processing techniques are used to resolve the target location to be tracked. Thus, the system is decoupled and applicable to closed systems without the need for a physical integration. Second, an infrared temperature sensor with a built-in laser for locating the measurement spot is deployed for non-contact temperature measurement of the moving target. Third, a predictive motion control system holds the thermal sensor and follows the moving target efficiently to enable continuous temperature measurement and monitoring.
Novel optoacoustic system for noninvasive continuous monitoring of cerebral venous blood oxygenation
NASA Astrophysics Data System (ADS)
Petrov, Yuriy; Petrov, Irene Y.; Prough, Donald S.; Esenaliev, Rinat O.
2012-02-01
Traumatic brain injury (TBI) and spinal cord injury are a major cause of death for individuals under 50 years of age. In the USA alone, 150,000 patients per year suffer moderate or severe TBI. Moreover, TBI is a major cause of combatrelated death. Monitoring of cerebral venous blood oxygenation is critically important for management of TBI patients because cerebral venous blood oxygenation below 50% results in death or severe neurologic complications. At present, there is no technique for noninvasive, accurate monitoring of this clinically important variable. We proposed to use optoacoustic technique for noninvasive monitoring of cerebral venous blood oxygenation by probing cerebral veins such as the superior sagittal sinus (SSS) and validated it in animal studies. In this work, we developed a novel, medical grade optoacoustic system for continuous, real-time cerebral venous blood oxygenation monitoring and tested it in human subjects at normal conditions and during hyperventilation to simulate changes that may occur in patients with TBI. We designed and built a highly-sensitive optoacoustic probe for SSS signal detection. Continuous measurements were performed in the near infrared spectral range and the SSS oxygenation absolute values were automatically calculated in real time using a special algorithm developed by our group. Continuous measurements performed at normal conditions and during hyperventilation demonstrated that hyperventilation resulted in approximately 12% decrease of cerebral venous blood oxygenation.
NASA Astrophysics Data System (ADS)
Thi Van Le, Khoa; Minkman, Ellen; Nguyen Thi Phuong, Thuy; Rutten, Martine; Bastiaanssen, Wim
2016-04-01
Remote sensing and citizen science can be utilized to fulfill the gap of conventional monitoring methods. However, how to engage these techniques, principally taking advantage of local capacities and of globally accessible data for satisfying the continuous data requirements and uncertainties are exciting challenges. Previous studies in Vietnam showed that official documents regulated towards responding the vital need of upgrading national water monitoring infrastructures do not put the huge potentials of free satellite images and crowd-based data collection into account, this factor also limits publications related to these techniques. In this research, a new water monitoring approach will be developed friendly with areas suffering poor quality monitoring works. Particularly, algorithms respecting to the relationship between temperature, total suspended sediment (TSS), chlorophyll and information collected by sensors onboard Landsat-8 and Sentinel-2 MSI satellites are built in the study area in Northern Vietnam; additionally, undergraduate student volunteers were sent to the sites with all the measurement activities are designed to coincide with the time when the study area captured by the satellites to compare the results. While conventional techniques are proving their irreplaceable role in the water monitoring network, the utilization of remote sensing techniques and citizen science in this study will demonstrate highly supportive values, saving monitoring costs and time; advantaging local human resources to science; providing an inclusive assessment of water quality changes along with land-use change in the study area, these approaches are excellent alternatives to meet the demand of real-time, continuous data nationwide.
Monitoring of the Educational Process during the Pedagogical Practical Training in School
ERIC Educational Resources Information Center
Saudabaeva, Gylmira; Tymbolova, Altynay; Kolumbaeva, Sholpan; Aitzhanova, Roza; Bodeev, Marat
2016-01-01
The purpose of the study is to analyze the features of monitoring the educational process during students' practical training at schools. We examined a number of methods and techniques of conducting monitoring of educational process as embodied by future teachers' practical training at secondary schools: continuous observation, method of test…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dinwiddie, Ralph Barton; Dehoff, Ryan R; Lloyd, Peter D
2013-01-01
Oak Ridge National Laboratory (ORNL) has been utilizing the ARCAM electron beam melting technology to additively manufacture complex geometric structures directly from powder. Although the technology has demonstrated the ability to decrease costs, decrease manufacturing lead-time and fabricate complex structures that are impossible to fabricate through conventional processing techniques, certification of the component quality can be challenging. Because the process involves the continuous deposition of successive layers of material, each layer can be examined without destructively testing the component. However, in-situ process monitoring is difficult due to metallization on inside surfaces caused by evaporation and condensation of metal from themore » melt pool. This work describes a solution to one of the challenges to continuously imaging inside of the chamber during the EBM process. Here, the utilization of a continuously moving Mylar film canister is described. Results will be presented related to in-situ process monitoring and how this technique results in improved mechanical properties and reliability of the process.« less
Learning temporal rules to forecast instability in continuously monitored patients
Dubrawski, Artur; Wang, Donghan; Hravnak, Marilyn; Clermont, Gilles; Pinsky, Michael R
2017-01-01
Inductive machine learning, and in particular extraction of association rules from data, has been successfully used in multiple application domains, such as market basket analysis, disease prognosis, fraud detection, and protein sequencing. The appeal of rule extraction techniques stems from their ability to handle intricate problems yet produce models based on rules that can be comprehended by humans, and are therefore more transparent. Human comprehension is a factor that may improve adoption and use of data-driven decision support systems clinically via face validity. In this work, we explore whether we can reliably and informatively forecast cardiorespiratory instability (CRI) in step-down unit (SDU) patients utilizing data from continuous monitoring of physiologic vital sign (VS) measurements. We use a temporal association rule extraction technique in conjunction with a rule fusion protocol to learn how to forecast CRI in continuously monitored patients. We detail our approach and present and discuss encouraging empirical results obtained using continuous multivariate VS data from the bedside monitors of 297 SDU patients spanning 29 346 hours (3.35 patient-years) of observation. We present example rules that have been learned from data to illustrate potential benefits of comprehensibility of the extracted models, and we analyze the empirical utility of each VS as a potential leading indicator of an impending CRI event. PMID:27274020
Use of Advanced Machine-Learning Techniques for Non-Invasive Monitoring of Hemorrhage
2010-04-01
that state-of-the-art machine learning techniques when integrated with novel non-invasive monitoring technologies could detect subtle, physiological...decompensation. Continuous, non-invasively measured hemodynamic signals (e.g., ECG, blood pressures, stroke volume) were used for the development of machine ... learning algorithms. Accuracy estimates were obtained by building models using 27 subjects and testing on the 28th. This process was repeated 28 times
Monitoring in traumatic brain injury.
Matz, P G; Pitts, L
1997-01-01
In the past several years, improvements in technology have advanced the monitoring capabilities for patients with TBI. The primary goal of monitoring the patient with TBI is to prevent secondary insults to the brain, primarily cerebral ischemia. Cerebral ischemia may occur early and without clinical correlation and portends a poor outcome. Measurement of ICP is the cornerstone of monitoring in the patient with TBI. Monitoring of ICP provides a measurement of CPP and a rough estimation of CBF. However, with alterations in pressure autoregulation, measurement of CPP does not always allow for determination of CBF. To circumvent this problem, direct measurements of CBF can be performed using clearance techniques (133Xe, N2O, Xe-CT) or invasive monitoring techniques (LDF, TDF, NIRS). Although direct and quantitative, clearance techniques do not allow for continuous monitoring. Invasive CBF monitoring techniques are new, and artifactual results can be problematic. The techniques of jugular venous saturation monitoring and TCD are well established and are powerful adjuncts to ICP monitoring. They allow the clinician to monitor cerebral oxygen extraction and blood flow velocity, respectively, for any given CPP. Use of TCD may predict posttraumatic vasospasm before clinical sequelae. Jugular venous saturation monitoring may detect clinically occult episodes of cerebral ischemia and increased oxygen extraction. Jugular venous saturation monitoring optimizes the use of hyperventilation in the treatment of intracranial hypertension. Although PET and SPECT scanning allow direct measurement of CMRO2, these techniques have limited application currently. Similarly, microdialysis is in its infancy but has demonstrated great promise for metabolic monitoring. EEG and SEP are excellent adjuncts to the monitoring arsenal and provide immediate information on current brain function. With improvements in electronic telemetry, functional monitoring by EEG or SEP may become an important part of routine monitoring in TBI.
A Wearable System for Real-Time Continuous Monitoring of Physical Activity
2018-01-01
Over the last decades, wearable systems have gained interest for monitoring of physiological variables, promoting health, and improving exercise adherence in different populations ranging from elite athletes to patients. In this paper, we present a wearable system for the continuous real-time monitoring of respiratory frequency (fR), heart rate (HR), and movement cadence during physical activity. The system has been experimentally tested in the laboratory (by simulating the breathing pattern with a mechanical ventilator) and by collecting data from one healthy volunteer. Results show the feasibility of the proposed device for real-time continuous monitoring of fR, HR, and movement cadence both in resting condition and during activity. Finally, different synchronization techniques have been investigated to enable simultaneous data collection from different wearable modules. PMID:29849993
Less or more hemodynamic monitoring in critically ill patients.
Jozwiak, Mathieu; Monnet, Xavier; Teboul, Jean-Louis
2018-06-07
Hemodynamic investigations are required in patients with shock to identify the type of shock, to select the most appropriate treatments and to assess the patient's response to the selected therapy. We discuss how to select the most appropriate hemodynamic monitoring techniques in patients with shock as well as the future of hemodynamic monitoring. Over the last decades, the hemodynamic monitoring techniques have evolved from intermittent toward continuous and real-time measurements and from invasive toward less-invasive approaches. In patients with shock, current guidelines recommend the echocardiography as the preferred modality for the initial hemodynamic evaluation. In patients with shock nonresponsive to initial therapy and/or in the most complex patients, it is recommended to monitor the cardiac output and to use advanced hemodynamic monitoring techniques. They also provide other useful variables that are useful for managing the most complex cases. Uncalibrated and noninvasive cardiac output monitors are not reliable enough in the intensive care setting. The use of echocardiography should be initially encouraged in patients with shock to identify the type of shock and to select the most appropriate therapy. The use of more invasive hemodynamic monitoring techniques should be discussed on an individualized basis.
Real-time monitoring of CO2 storage sites: Application to Illinois Basin-Decatur Project
Picard, G.; Berard, T.; Chabora, E.; Marsteller, S.; Greenberg, S.; Finley, R.J.; Rinck, U.; Greenaway, R.; Champagnon, C.; Davard, J.
2011-01-01
Optimization of carbon dioxide (CO2) storage operations for efficiency and safety requires use of monitoring techniques and implementation of control protocols. The monitoring techniques consist of permanent sensors and tools deployed for measurement campaigns. Large amounts of data are thus generated. These data must be managed and integrated for interpretation at different time scales. A fast interpretation loop involves combining continuous measurements from permanent sensors as they are collected to enable a rapid response to detected events; a slower loop requires combining large datasets gathered over longer operational periods from all techniques. The purpose of this paper is twofold. First, it presents an analysis of the monitoring objectives to be performed in the slow and fast interpretation loops. Second, it describes the implementation of the fast interpretation loop with a real-time monitoring system at the Illinois Basin-Decatur Project (IBDP) in Illinois, USA. ?? 2011 Published by Elsevier Ltd.
Kern, Christoph; Sutton, Jeff; Elias, Tamar; Lee, Robert Lopaka; Kamibayashi, Kevan P.; Antolik, Loren; Werner, Cynthia A.
2015-01-01
SO2 camera systems allow rapid two-dimensional imaging of sulfur dioxide (SO2) emitted from volcanic vents. Here, we describe the development of an SO2 camera system specifically designed for semi-permanent field installation and continuous use. The integration of innovative but largely “off-the-shelf” components allowed us to assemble a robust and highly customizable instrument capable of continuous, long-term deployment at Kīlauea Volcano's summit Overlook Crater. Recorded imagery is telemetered to the USGS Hawaiian Volcano Observatory (HVO) where a novel automatic retrieval algorithm derives SO2 column densities and emission rates in real-time. Imagery and corresponding emission rates displayed in the HVO operations center and on the internal observatory website provide HVO staff with useful information for assessing the volcano's current activity. The ever-growing archive of continuous imagery and high-resolution emission rates in combination with continuous data from other monitoring techniques provides insight into shallow volcanic processes occurring at the Overlook Crater. An exemplary dataset from September 2013 is discussed in which a variation in the efficiency of shallow circulation and convection, the processes that transport volatile-rich magma to the surface of the summit lava lake, appears to have caused two distinctly different phases of lake activity and degassing. This first successful deployment of an SO2 camera for continuous, real-time volcano monitoring shows how this versatile technique might soon be adapted and applied to monitor SO2 degassing at other volcanoes around the world.
NASA Astrophysics Data System (ADS)
Kern, Christoph; Sutton, Jeff; Elias, Tamar; Lee, Lopaka; Kamibayashi, Kevan; Antolik, Loren; Werner, Cynthia
2015-07-01
SO2 camera systems allow rapid two-dimensional imaging of sulfur dioxide (SO2) emitted from volcanic vents. Here, we describe the development of an SO2 camera system specifically designed for semi-permanent field installation and continuous use. The integration of innovative but largely ;off-the-shelf; components allowed us to assemble a robust and highly customizable instrument capable of continuous, long-term deployment at Kīlauea Volcano's summit Overlook Crater. Recorded imagery is telemetered to the USGS Hawaiian Volcano Observatory (HVO) where a novel automatic retrieval algorithm derives SO2 column densities and emission rates in real-time. Imagery and corresponding emission rates displayed in the HVO operations center and on the internal observatory website provide HVO staff with useful information for assessing the volcano's current activity. The ever-growing archive of continuous imagery and high-resolution emission rates in combination with continuous data from other monitoring techniques provides insight into shallow volcanic processes occurring at the Overlook Crater. An exemplary dataset from September 2013 is discussed in which a variation in the efficiency of shallow circulation and convection, the processes that transport volatile-rich magma to the surface of the summit lava lake, appears to have caused two distinctly different phases of lake activity and degassing. This first successful deployment of an SO2 camera for continuous, real-time volcano monitoring shows how this versatile technique might soon be adapted and applied to monitor SO2 degassing at other volcanoes around the world.
Method and apparatus for monitoring mercury emissions
Durham, Michael D.; Schlager, Richard J.; Sappey, Andrew D.; Sagan, Francis J.; Marmaro, Roger W.; Wilson, Kevin G.
1997-01-01
A mercury monitoring device that continuously monitors the total mercury concentration in a gas. The device uses the same chamber for converting speciated mercury into elemental mercury and for measurement of the mercury in the chamber by radiation absorption techniques. The interior of the chamber is resistant to the absorption of speciated and elemental mercury at the operating temperature of the chamber.
Method and apparatus for monitoring mercury emissions
Durham, M.D.; Schlager, R.J.; Sappey, A.D.; Sagan, F.J.; Marmaro, R.W.; Wilson, K.G.
1997-10-21
A mercury monitoring device that continuously monitors the total mercury concentration in a gas. The device uses the same chamber for converting speciated mercury into elemental mercury and for measurement of the mercury in the chamber by radiation absorption techniques. The interior of the chamber is resistant to the absorption of speciated and elemental mercury at the operating temperature of the chamber. 15 figs.
Clinical outcome of continuous facial nerve monitoring during primary parotidectomy.
Terrell, J E; Kileny, P R; Yian, C; Esclamado, R M; Bradford, C R; Pillsbury, M S; Wolf, G T
1997-10-01
To assess whether continuous facial nerve monitoring during parotidectomy is associated with a lower incidence of facial nerve paresis or paralysis compared with parotidectomy without monitoring and to assess the cost of such monitoring. A retrospective analysis of outcomes for patients who underwent parotidectomy with or without continuous facial nerve monitoring. University medical center. Fifty-six patients undergoing parotidectomy in whom continuous electromyographic monitoring was used and 61 patients in whom it was not used. (1) The incidence of early and persistent facial nerve paresis or paralysis and (2) the cost associated with facial nerve monitoring. Early, unintentional facial weakness was significantly lower in the group monitored by electromyograpy (43.6%) than in the unmonitored group (62.3%) (P=.04). In the subgroup of patients without comorbid conditions or surgeries, early weakness in the monitored group (33.3%) remained statistically lower than the rate of early weakness in the unmonitored group (57.5%) (P=.03). There was no statistical difference in the final facial nerve function or incidence of permanent nerve injury between the groups or subgroups. After multivariate analysis, nonmonitored status (odds ratio [OR], 3.22), advancing age (OR, 1.47 per 10 years), and longer operative times (OR, 1.3 per hour) were the only significant independent predictive variables significantly associated with early postoperative facial weakness. The incremental cost of facial nerve monitoring was $379. The results suggest that continuous electromyographic monitoring of facial muscle during primary parotidectomy reduces the incidence of short-term postoperative facial paresis. Advantages and disadvantages of this technique need to be considered together with the additional costs in deciding whether routine use of continuous monitoring is a useful, cost-effective adjunct to parotid surgery.
Detection and Monitoring of Airborne Nuclear Waste Materials. Annual Report to Department of Energy.
1979-12-04
an active core , its detection by counting techniques is often slow and impractical. For these reasons NRL under contract with DoE undertook develop ...Protection and Measurements, Tritium Measurement Techniques NCRP Report No. 47 (1976). 2. " Development of a Continuous Tritium Monitor for Fuel Reprocessing...Trans. Am. Nucl. Soc. 21, 91 (1975). 146. "Process Behavior of and Environmental Assessments of C Releases from an HTGR Fuel Reprocessing Facility" J. W
Panfili, G; Piccini, L; Maggi, L; Parini, S; Andreoni, G
2006-01-01
In this study we explored the possibility to realize a low power device for Cardiac Output continuous monitoring based on impedance cardiography technique. We assessed the possibility to develop a system able to record data allow an intra-subjective analysis based on the daily variations of this measure. The device was able to acquire and to send signals using a wireless Bluetooth transmission. The electronic circuit was designed in order to minimize power consumption, dimension and weight. The reported results were interesting for what concerns the power consumption and then noise level. In this way was obtained a wearable device that will permit to define specific clinical protocols based on continuous monitoring of the Cardiac Output signal.
Wood, Martin James; McMillen, Jason
2014-01-01
This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique.
McMillen, Jason
2014-01-01
Objective This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Methods Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Results Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. Conclusion The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. PMID:25694919
Brain Tissue Oxygen Monitoring and the Intersection of Brain and Lung: A Comprehensive Review.
Ngwenya, Laura B; Burke, John F; Manley, Geoffrey T
2016-09-01
Traumatic brain injury is a problem that affects millions of Americans yearly and for which there is no definitive treatment that improves outcome. Continuous brain tissue oxygen (PbtO2 ) monitoring is a complement to traditional brain monitoring techniques, such as intracranial pressure and cerebral perfusion pressure. PbtO2 monitoring has not yet become a clinical standard of care, due to several unresolved questions. In this review, we discuss the rationale and technology of PbtO2 monitoring. We review the literature, both historic and current, and show that continuous PbtO2 monitoring is feasible and useful in patient management. PbtO2 numbers reflect cerebral blood flow and oxygen diffusion. Thus, continuous monitoring of PbtO2 yields important information about both the brain and the lung. The preclinical and clinical studies demonstrating these findings are discussed. In this review, we demonstrate that patient management in a PbtO2 -directed fashion is not the sole answer to the problem of treating traumatic brain injury but is an important adjunct to the armamentarium of multimodal neuromonitoring. Copyright © 2016 by Daedalus Enterprises.
Glyph-based generic network visualization
NASA Astrophysics Data System (ADS)
Erbacher, Robert F.
2002-03-01
Network managers and system administrators have an enormous task set before them in this day of growing network usage. This is particularly true of e-commerce companies and others dependent on a computer network for their livelihood. Network managers and system administrators must monitor activity for intrusions and misuse while at the same time monitoring performance of the network. In this paper, we describe our visualization techniques for assisting in the monitoring of networks for both of these tasks. The goal of these visualization techniques is to integrate the visual representation of both network performance/usage as well as data relevant to intrusion detection. The main difficulties arise from the difference in the intrinsic data and layout needs of each of these tasks. Glyph based techniques are additionally used to indicate the representative values of the necessary data parameters over time. Additionally, our techniques are geared towards providing an environment that can be used continuously for constant real-time monitoring of the network environment.
A real time study on condition monitoring of distribution transformer using thermal imager
NASA Astrophysics Data System (ADS)
Mariprasath, T.; Kirubakaran, V.
2018-05-01
The transformer is one of the critical apparatus in the power system. At any cost, a few minutes of outages harshly influence the power system. Hence, prevention-based maintenance technique is very essential. The continuous conditioning and monitoring technology significantly increases the life span of the transformer, as well as reduces the maintenance cost. Hence, conditioning and monitoring of transformer's temperature are very essential. In this paper, a critical review has been made on various conditioning and monitoring techniques. Furthermore, a new method, hot spot indication technique, is discussed. Also, transformer's operating condition is monitored by using thermal imager. From the thermal analysis, it is inferred that major hotspot locations are appearing at connection lead out; also, the bushing of the transformer is the very hottest spot in transformer, so monitoring the level of oil is essential. Alongside, real time power quality analysis has been carried out using the power analyzer. It shows that industrial drives are injecting current harmonics to the distribution network, which causes the power quality problem on the grid. Moreover, the current harmonic limit has exceeded the IEEE standard limit. Hence, the adequate harmonics suppression technique is need an hour.
A Managed Care Model for the Military Departments
1990-05-15
Seattle reports that a widely used technique for electronic monitoring of a fetal heart during delivery is "no more effective than a stethoscope in 6...detecting fetal distress." The study director went on to say that obstetricians will probably continue to use the technique to avoid possible
Learning temporal rules to forecast instability in continuously monitored patients.
Guillame-Bert, Mathieu; Dubrawski, Artur; Wang, Donghan; Hravnak, Marilyn; Clermont, Gilles; Pinsky, Michael R
2017-01-01
Inductive machine learning, and in particular extraction of association rules from data, has been successfully used in multiple application domains, such as market basket analysis, disease prognosis, fraud detection, and protein sequencing. The appeal of rule extraction techniques stems from their ability to handle intricate problems yet produce models based on rules that can be comprehended by humans, and are therefore more transparent. Human comprehension is a factor that may improve adoption and use of data-driven decision support systems clinically via face validity. In this work, we explore whether we can reliably and informatively forecast cardiorespiratory instability (CRI) in step-down unit (SDU) patients utilizing data from continuous monitoring of physiologic vital sign (VS) measurements. We use a temporal association rule extraction technique in conjunction with a rule fusion protocol to learn how to forecast CRI in continuously monitored patients. We detail our approach and present and discuss encouraging empirical results obtained using continuous multivariate VS data from the bedside monitors of 297 SDU patients spanning 29 346 hours (3.35 patient-years) of observation. We present example rules that have been learned from data to illustrate potential benefits of comprehensibility of the extracted models, and we analyze the empirical utility of each VS as a potential leading indicator of an impending CRI event. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Acoustic Techniques for Structural Health Monitoring
NASA Astrophysics Data System (ADS)
Frankenstein, B.; Augustin, J.; Hentschel, D.; Schubert, F.; Köhler, B.; Meyendorf, N.
2008-02-01
Future safety and maintenance strategies for industrial components and vehicles are based on combinations of monitoring systems that are permanently attached to or embedded in the structure, and periodic inspections. The latter belongs to conventional nondestructive evaluation (NDE) and can be enhanced or partially replaced by structural health monitoring systems. However, the main benefit of this technology for the future will consist of systems that can be differently designed based on improved safety philosophies, including continuous monitoring. This approach will increase the efficiency of inspection procedures at reduced inspection times. The Fraunhofer IZFP Dresden Branch has developed network nodes, miniaturized transmitter and receiver systems for active and passive acoustical techniques and sensor systems that can be attached to or embedded into components or structures. These systems have been used to demonstrate intelligent sensor networks for the monitoring of aerospace structures, railway systems, wind energy generators, piping system and other components. Material discontinuities and flaws have been detected and monitored during full scale fatigue testing. This paper will discuss opportunities and future trends in nondestructive evaluation and health monitoring based on new sensor principles and advanced microelectronics. It will outline various application examples of monitoring systems based on acoustic techniques and will indicate further needs for research and development.
NASA Astrophysics Data System (ADS)
Saari, Markus; Rossi, Pekka; Blomberg von der Geest, Kalle; Mäkinen, Ari; Postila, Heini; Marttila, Hannu
2017-04-01
High metal concentrations in natural waters is one of the key environmental and health problems globally. Continuous in-situ analysis of metals from runoff water is technically challenging but essential for the better understanding of processes which lead to pollutant transport. Currently, typical analytical methods for monitoring elements in liquids are off-line laboratory methods such as ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (ICP combined with a mass spectrometer). Disadvantage of the both techniques is time consuming sample collection, preparation, and off-line analysis at laboratory conditions. Thus use of these techniques lack possibility for real-time monitoring of element transport. We combined a novel high resolution on-line metal concentration monitoring with catchment scale physical hydrological modelling in Mustijoki river in Southern Finland in order to study dynamics of processes and form a predictive warning system for leaching of metals. A novel on-line measurement technique based on micro plasma emission spectroscopy (MPES) is tested for on-line detection of selected elements (e.g. Na, Mg, Al, K, Ca, Fe, Ni, Cu, Cd and Pb) in runoff waters. The preliminary results indicate that MPES can sufficiently detect and monitor metal concentrations from river water. Water and Soil Assessment Tool (SWAT) catchment scale model was further calibrated with high resolution metal concentration data. We show that by combining high resolution monitoring and catchment scale physical based modelling, further process studies and creation of early warning systems, for example to optimization of drinking water uptake from rivers, can be achieved.
Detection of essential hypertension with physiological signals from wearable devices.
Ghosh, Arindam; Torres, Juan Manuel Mayor; Danieli, Morena; Riccardi, Giuseppe
2015-08-01
Early detection of essential hypertension can support the prevention of cardiovascular disease, a leading cause of death. The traditional method of identification of hypertension involves periodic blood pressure measurement using brachial cuff-based measurement devices. While these devices are non-invasive, they require manual setup for each measurement and they are not suitable for continuous monitoring. Research has shown that physiological signals such as Heart Rate Variability, which is a measure of the cardiac autonomic activity, is correlated with blood pressure. Wearable devices capable of measuring physiological signals such as Heart Rate, Galvanic Skin Response, Skin Temperature have recently become ubiquitous. However, these signals are not accurate and are prone to noise due to different artifacts. In this paper a) we present a data collection protocol for continuous non-invasive monitoring of physiological signals from wearable devices; b) we implement signal processing techniques for signal estimation; c) we explore how the continuous monitoring of these physiological signals can be used to identify hypertensive patients; d) We conduct a pilot study with a group of normotensive and hypertensive patients to test our techniques. We show that physiological signals extracted from wearable devices can distinguish between these two groups with high accuracy.
In-situ measurement of processing properties during fabrication in a production tool
NASA Technical Reports Server (NTRS)
Kranbuehl, D. E.; Haverty, P.; Hoff, M.; Loos, A. C.
1988-01-01
Progress is reported on the use of frequency-dependent electromagnetic measurements (FDEMs) as a single, convenient technique for continuous in situ monitoring of polyester cure during fabrication in a laboratory and manufacturing environment. Preliminary FDEM sensor and modeling work using the Loss-Springer model in order to develop an intelligent closed-loop, sensor-controlled cure process is described. FDEMs using impedance bridges in the Hz to MHz region is found to be ideal for automatically monitoring polyester processing properties continuously throughout the cure cycle.
Fully integrated biochip platforms for advanced healthcare.
Carrara, Sandro; Ghoreishizadeh, Sara; Olivo, Jacopo; Taurino, Irene; Baj-Rossi, Camilla; Cavallini, Andrea; de Beeck, Maaike Op; Dehollain, Catherine; Burleson, Wayne; Moussy, Francis Gabriel; Guiseppi-Elie, Anthony; De Micheli, Giovanni
2012-01-01
Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications.
Fully Integrated Biochip Platforms for Advanced Healthcare
Carrara, Sandro; Ghoreishizadeh, Sara; Olivo, Jacopo; Taurino, Irene; Baj-Rossi, Camilla; Cavallini, Andrea; de Beeck, Maaike Op; Dehollain, Catherine; Burleson, Wayne; Moussy, Francis Gabriel; Guiseppi-Elie, Anthony; De Micheli, Giovanni
2012-01-01
Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications. PMID:23112644
Electron line shape and transmission function of the KATRIN monitor spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slezák, M.
Knowledge of the neutrino mass is of particular interest in modern neutrino physics. Besides the neutrinoless double beta decay and cosmological observation information about the neutrino mass is obtained from single beta decay by observing the shape of the electron spectrum near the endpoint. The KATRIN β decay experiment aims to push the limit on the effective electron antineutrino mass down to 0.2 eV/c{sup 2}. To reach this sensitivity several systematic effects have to be under control. One of them is the fluctuations of the absolute energy scale, which therefore has to be continuously monitored at very high precision. Thismore » paper shortly describes KATRIN, the technique for continuous monitoring of the absolute energy scale and recent improvements in analysis of the monitoring data.« less
NASA Astrophysics Data System (ADS)
Larin, Kirill V.
Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in the glucose clamping experiments (characterized by slow, controlled increase of the blood glucose concentration); and (4) the accuracy of glucose concentration monitoring may substantially be improved if optimal dimensions of the probed skin area are used. The results suggest that high-resolution OCT technique has a potential for noninvasive, accurate, and continuous glucose monitoring with high sensitivity.
Continuous welding of unidirectional fiber reinforced thermoplastic tape material
NASA Astrophysics Data System (ADS)
Schledjewski, Ralf
2017-10-01
Continuous welding techniques like thermoplastic tape placement with in situ consolidation offer several advantages over traditional manufacturing processes like autoclave consolidation, thermoforming, etc. However, still there is a need to solve several important processing issues before it becomes a viable economic process. Intensive process analysis and optimization has been carried out in the past through experimental investigation, model definition and simulation development. Today process simulation is capable to predict resulting consolidation quality. Effects of material imperfections or process parameter variations are well known. But using this knowledge to control the process based on online process monitoring and according adaption of the process parameters is still challenging. Solving inverse problems and using methods for automated code generation allowing fast implementation of algorithms on targets are required. The paper explains the placement technique in general. Process-material-property-relationships and typical material imperfections are described. Furthermore, online monitoring techniques and how to use them for a model based process control system are presented.
Wu, Hongpeng; Dong, Lei; Zheng, Huadan; Yu, Yajun; Ma, Weiguang; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang; Tittel, Frank K.
2017-01-01
Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a sensitive gas detection technique which requires frequent calibration and has a long response time. Here we report beat frequency (BF) QEPAS that can be used for ultra-sensitive calibration-free trace-gas detection and fast spectral scan applications. The resonance frequency and Q-factor of the quartz tuning fork (QTF) as well as the trace-gas concentration can be obtained simultaneously by detecting the beat frequency signal generated when the transient response signal of the QTF is demodulated at its non-resonance frequency. Hence, BF-QEPAS avoids a calibration process and permits continuous monitoring of a targeted trace gas. Three semiconductor lasers were selected as the excitation source to verify the performance of the BF-QEPAS technique. The BF-QEPAS method is capable of measuring lower trace-gas concentration levels with shorter averaging times as compared to conventional PAS and QEPAS techniques and determines the electrical QTF parameters precisely. PMID:28561065
NASA Astrophysics Data System (ADS)
Gopal Madhav Annamdas, Venu; Kiong Soh, Chee
2017-01-01
Continuous structural health monitoring (SHM) and delayed SHM techniques can be contact/ contactless, surface bonded/embedded, wired/wireless and active/passive actuator-sensor systems which transfer the recorded condition of the structure to the base station almost instantaneously or with time delay respectively. The time between fatal crack initiation and its propagation leading to the collapse of key infrastructures such as aerospace, nuclear facilities, oil and gas is mostly short. Timely discovery of structural problem depends heavily on the scanning period in well-established techniques like piezoelectric (PZT) based electromechanical impedance (EMI) technique. This often takes much scanning time due to the acquisition of resonant structural peaks at all frequencies in the considered bandwidth; thus poses a challenge for its implementation in practice. On the other hand, recently developed strain sensors based on metamaterials and their breeds such as nested split-ring resonators, localized surface plasmons (LSP), etc, employ measurement of reflected or transmitted signal, with super-fast scanning in the order of at most 1/100th of the time taken by the EMI technique. This paper articulates faster measurements by reducing unnecessary resonant structural peaks and focusing on rapid monitoring using PZT and metamaterial plasmons. Our research adopted wired PZT and wireless LSP communications with impedance analyser and vector network analyser respectively. We present integrated and complementary nature of these techniques, which can be processed rapidly for key infrastructures with great effectiveness. This integration can result in both continuous and delayed SHM techniques based on time or frequency or both domains.
Space shuttle propulsion systems on-board checkout and monitoring system development study
NASA Technical Reports Server (NTRS)
1971-01-01
Investigations on the fundamental space shuttle propulsion systems program are reported, with emphasis on in-depth reviews of preliminary drafts of the guidelines. The guidelines will be used to incorporate the onboard checkout and monitoring function into the basic design of the propulsion systems and associated interfacing systems. The analysis of checkout and monitoring requirements of the Titan 3 L expandable booster propulsion systems was completed, and the techniques for accomplishing the checkout and monitoring functions were determined. Updating results of the basic study of propulsion system checkout and monitoring is continuing.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-09-24
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.
NASA Astrophysics Data System (ADS)
Lachance, R. L.; Gordley, L. L.; Marshall, B. T.; Fisher, J.; Paxton, G.; Gubeli, J. F.
2015-12-01
Currently there is no efficient and affordable way to monitor gas releases over small to large areas. We have demonstrated the ability to accurately measure key greenhouse and pollutant gasses with low cost solar observations using the breakthrough sensor technology called the "Pupil Imaging Gas Correlation", PIGC™, which provides size and complexity reduction while providing exceptional resolution and coverage for various gas sensing applications. It is a practical implementation of the well-known Gas Filter Correlation Radiometry (GFCR) technique used for the HALOE and MOPITT satellite instruments that were flown on successful NASA missions in the early 2000s. This strong space heritage brings performance and reliability to the ground instrument design. A methane (CH4) abundance sensitivity of 0.5% or better of ambient column with uncooled microbolometers has been demonstrated with 1 second direct solar observations. These under $10 k sensors can be deployed in precisely balanced autonomous grids to monitor the flow of chosen gasses, and infer their source locations. Measureable gases include CH4, 13CO2, N2O, NO, NH3, CO, H2S, HCN, HCl, HF, HDO and others. A single instrument operates in a dual operation mode, at no additional cost, for continuous (real-time 24/7) local area perimeter monitoring for the detection of leaks for safety & security needs, looking at an artificial light source (for example a simple 60 W light bulb placed 100 m away), while simultaneously allowing solar observation for quasi-continuous wide area total atmospheric column scanning (3-D) for environmental monitoring (fixed and mobile configurations). The second mode of operation continuously quantifies the concentration and flux of specific gases over different ground locations, determined the amount of targeted gas being released from the area or getting into the area from outside locations, allowing better tracking of plumes and identification of sources. This paper reviews the measurement technique, performance demonstration and grid deployment strategy.
NASA Astrophysics Data System (ADS)
Wang, Chun-Hsiung; Chiu, Shih-Yung; Hsu, Yu-Hsiang; Lee, Shu-Sheng; Lee, Chih-Kung
2017-06-01
A non-contact arterial-induced skin vibration inspection system is implemented. This optical metrology system is constructed with shadow Moiré configuration and the fringe analysis algorithm. Developed with the Region of Interested (ROI) capturing technique and the Two-dimensional Wavelet Transform (2D-CWT) method, this algorithm is able to retrieve the height-correlated phase information from the shadow Moiré fringe patterns. Using a commercial video camera or a CMOS image sensor, this system could monitor the skin-vibration induced by the cyclic deformation of inner layered artery. The cross-sectional variation and the rhythm of heart cycle could be continuously measured for health monitoring purposes. The average vibration amplitude of the artery at the wrist ranges between 20 μm and 50 μm, which is quite subtle comparing with the skin surface structure. Having the non-stationary motion of human body, the traditional phase shifting (PS) technique can be very unstable due to the requirement of several frames of images, especially for case that artery is continuously pumping. To bypass this fundamental issue, the shadow Moiré technique is introduced to enhance the surface deformation characteristic. And the phase information is retrieved by the means of spectrum filtering instead of PS technique, which the phase is calculated from intensity maps of multiple images. The instantaneous surface can therefore be reconstructed individually from each frame, enabling the subtle arterial-induced skin vibration measurement. The comparative results of phase reconstruction between different fringe analysis algorithms will be demonstrated numerically and experimentally. And the electrocardiography (ECG) results will used as the reference for the validity of health monitoring potential of the non-contact arterial-induced skin vibration inspection system.
NASA Astrophysics Data System (ADS)
Tauro, Flavia; Grimaldi, Salvatore
2017-04-01
Recently, several efforts have been devoted to the design and development of innovative, and often unintended, approaches for the acquisition of hydrological data. Among such pioneering techniques, this presentation reports recent advancements towards the establishment of a novel noninvasive and potentially continuous methodology based on the acquisition and analysis of images for spatially distributed observations of the kinematics of surface waters. The approach aims at enabling rapid, affordable, and accurate surface flow monitoring of natural streams. Flow monitoring is an integral part of hydrological sciences and is essential for disaster risk reduction and the comprehension of natural phenomena. However, water processes are inherently complex to observe: they are characterized by multiscale and highly heterogeneous phenomena which have traditionally demanded sophisticated and costly measurement techniques. Challenges in the implementation of such techniques have also resulted in lack of hydrological data during extreme events, in difficult-to-access environments, and at high temporal resolution. By combining low-cost yet high-resolution images and several velocimetry algorithms, noninvasive flow monitoring has been successfully conducted at highly heterogeneous scales, spanning from rills to highly turbulent streams, and medium-scale rivers, with minimal supervision by external users. Noninvasive image data acquisition has also afforded observations in high flow conditions. Latest novelties towards continuous flow monitoring at the catchment scale have entailed the development of a remote gauge-cam station on the Tiber River and integration of flow monitoring through image analysis with unmanned aerial systems (UASs) technology. The gauge-cam station and the UAS platform both afford noninvasive image acquisition and calibration through an innovative laser-based setup. Compared to traditional point-based instrumentation, images allow for generating surface flow velocity maps which fully describe the kinematics of the velocity field in natural streams. Also, continuous observations provide a close picture of the evolving dynamics of natural water bodies. Despite such promising achievements, dealing with images also involves coping with adverse illumination, massive data handling and storage, and data-intensive computing. Most importantly, establishing a novel observational technique requires estimation of the uncertainty associated to measurements and thorough comparison to existing benchmark approaches. In this presentation, we provide answers to some of these issues and perspectives for future research.
Monitoring beach changes using GPS surveying techniques
Morton, Robert; Leach, Mark P.; Paine, Jeffrey G.; Cardoza, Michael A.
1993-01-01
The adaptation of Global Positioning System (GPS) surveying techniques to beach monitoring activities is a promising response to this challenge. An experiment that employed both GPS and conventional beach surveying was conducted, and a new beach monitoring method employing kinematic GPS surveys was devised. This new method involves the collection of precise shore-parallel and shore-normal GPS positions from a moving vehicle so that an accurate two-dimensional beach surface can be generated. Results show that the GPS measurements agree with conventional shore-normal surveys at the 1 cm level, and repeated GPS measurements employing the moving vehicle demonstrate a precision of better than 1 cm. In addition, the nearly continuous sampling and increased resolution provided by the GPS surveying technique reveals alongshore changes in beach morphology that are undetected by conventional shore-normal profiles. The application of GPS surveying techniques combined with the refinement of appropriate methods for data collection and analysis provides a better understanding of beach changes, sediment transport, and storm impacts.
Guerrero-Domínguez, R; González-González, G; Rubio-Romero, R; Federero-Martínez, F; Jiménez, I
2016-05-01
The intraoperative neurophysiological monitoring is a technique used to test and monitor nervous function. This technique has become essential in some neurosurgery interventions, since it avoids neurological injuries during surgery and reduces morbidity. The experience of intraoperative neurophysiological monitoring is limited in some clinical cases due to the low incidence of pregnant women undergoing a surgical procedure. A case is presented of a 29-weeks pregnant woman suffering from a cervical intraspinal tumour with intense pain, which required surgery. The collaboration of a multidisciplinary team composed of anaesthesiologists, neurosurgeons, neurophysiologists and obstetricians, the continuous monitoring of the foetus, the intraoperative neurophysiological monitoring, and maintaining the neurophysiological and utero-placental variables were crucial for the proper development of the surgery. According to our experience and the limited publications in the literature, no damaging effects of this technique were detected at maternal-foetal level. On the contrary, it brings important benefits during the surgery and for the final result. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Continuous acoustic emission monitoring of reinforced concrete under accelerated corrosion
NASA Astrophysics Data System (ADS)
Di Benedetti, M.; Loreto, G.; Nanni, A.; Matta, F.; Gonzalez-Nunez, M. A.
2011-04-01
The development of techniques capable of evaluating deterioration of reinforced concrete (RC) structures is instrumental to the advancement of techniques for the structural health monitoring (SHM) and service life estimate for constructed facilities. One of the main causes leading to degradation of RC is the corrosion of the steel reinforcement. This process can be modeled phenomenologically, while laboratory tests aimed at studying durability responses are typically accelerated in order to provide useful results within a realistic period of time. To assess the condition of damage in RC, a number of nondestructive methods have been recently studied. Acoustic emission (AE) is emerging as a nondestructive tool to detect the onset and progression of deterioration mechanisms. In this paper, the development of accelerated corrosion and continuous AE monitoring test set-up for RC specimens are presented. Relevant information are provided with regard to the characteristics of the corrosion circuit, continuous measurement and acquisition of corrosion potential, selection of AE sensors and AE parameter setting. The effectiveness of the setup in detecting and characterizing the initiation and progression of the corrosion phenomenon is discussed on the basis of preliminary results from small-scale, pre-cracked RC specimens, which are representative of areas near the clear cover in typical RC bridge members.
Sutha, P; Jayanthi, V E
2017-12-08
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
López, María Mercedes; Guasch, Emilia; Schiraldi, Renato; Maggi, Genaro; Alonso, Eduardo; Gilsanz, Fernando
2016-01-01
Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Evaluation of Biofilms and the Effects of Biocides Thereon
NASA Technical Reports Server (NTRS)
Pierson, Duane L. (Inventor); Koenig, David W. (Inventor); Mishra, Saroj K. (Inventor)
2002-01-01
Biofilm formation is monitored by real-time continuous measurement. Images are formed of sessile cells on a surface and planktonic cells adjacent the surface. The attachment of cells to the surface is measured and quantitated, and sessile and planktonic cells are distinguished using image processing techniques. Single cells as well as colonies are monitored on or adjacent a variety of substrates. Flowing streams may be monitored. The effects of biocides on biofilms commonly isolated from recyclable water systems are measured.
Working papers: applicability of Box Jenkins techniques to gasoline consumption forecasting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Reliable consumption forecasts are needed, however, traditional linear time-series techniques don't adequately account for an environment so subject to change. This report evaluates the use of Box Jenkins techniques for gasoline consumption forecasting. Box Jenkins methods were applied to data obtained from the Colorado Petroleum Association and the Colorado Highway Users Fund to ''predict'' 1978 and 1979 consumption. These results prove the Box Jenkins techniques to be quite effective. Forecasts for 1980-81 are included along with suggestions for continuous use of the technique to monitor consumption.
NASA Astrophysics Data System (ADS)
Larin, Kirill V.; Ashitkov, Taras V.; Larina, Irina V.; Petrova, Irina Y.; Eledrisi, Mohsen S.; Motamedi, Massoud; Esenaliev, Rinat O.
2002-06-01
Continuous noninvasive monitoring of blood glucose concentration can improve management of Diabetes Mellitus, reduce mortality, and considerably improve quality of life of diabetic patients. Recently, we proposed to use the OCT technique for noninvasive glucose monitoring. In this paper, we tested noninvasive blood glucose monitoring with the OCT technique in phantoms, animals, and human subjects. An OCT system with the wavelength of 1300 nm was used in our experiments. Phantom studies performed on aqueous suspensions of polystyrene microspheres and milk showed 3.2% decrease of exponential slope of OCT signals when glucose concentration increased from 0 to 100 mM. Theoretical calculations based on the Mie theory of scattering support the results obtained in phantoms. Bolus glucose injections and glucose clamping experiments were performed in animals (New Zealand rabbits and Yucatan micropigs). Good correlation between changes in the OCT signal slope and actual blood glucose concentration were observed in these experiments. First studies were performed in healthy human subjects (using oral glucose tolerance tests). Dependence of the slope of the OCT signals on the actual blood glucose concentration was similar to that obtained in animal studies. Our studies suggest that the OCT technique can potentially be used for noninvasive blood glucose monitoring.
Webb, R. Chad; Ma, Yinji; Krishnan, Siddharth; Li, Yuhang; Yoon, Stephen; Guo, Xiaogang; Feng, Xue; Shi, Yan; Seidel, Miles; Cho, Nam Heon; Kurniawan, Jonas; Ahad, James; Sheth, Niral; Kim, Joseph; Taylor VI, James G.; Darlington, Tom; Chang, Ken; Huang, Weizhong; Ayers, Joshua; Gruebele, Alexander; Pielak, Rafal M.; Slepian, Marvin J.; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.
2015-01-01
Continuous monitoring of variations in blood flow is vital in assessing the status of microvascular and macrovascular beds for a wide range of clinical and research scenarios. Although a variety of techniques exist, most require complete immobilization of the subject, thereby limiting their utility to hospital or clinical settings. Those that can be rendered in wearable formats suffer from limited accuracy, motion artifacts, and other shortcomings that follow from an inability to achieve intimate, noninvasive mechanical linkage of sensors with the surface of the skin. We introduce an ultrathin, soft, skin-conforming sensor technology that offers advanced capabilities in continuous and precise blood flow mapping. Systematic work establishes a set of experimental procedures and theoretical models for quantitative measurements and guidelines in design and operation. Experimental studies on human subjects, including validation with measurements performed using state-of-the-art clinical techniques, demonstrate sensitive and accurate assessment of both macrovascular and microvascular flow under a range of physiological conditions. Refined operational modes eliminate long-term drifts and reduce power consumption, thereby providing steps toward the use of this technology for continuous monitoring during daily activities. PMID:26601309
Overview of selected surrogate technologies for continuous suspended-sediment monitoring
Gray, J.R.; Gartner, J.W.
2006-01-01
Surrogate technologies for inferring selected characteristics of suspended sediments in surface waters are being tested by the U.S. Geological Survey and several partners with the ultimate goal of augmenting or replacing traditional monitoring methods. Optical properties of water such as turbidity and optical backscatter are the most commonly used surrogates for suspended-sediment concentration, but use of other techniques such as those based on acoustic backscatter, laser diffraction, digital photo-optic, and pressure-difference principles is increasing for concentration and, in some cases, particle-size distribution and flux determinations. The potential benefits of these technologies include acquisition of automated, continuous, quantifiably accurate data obtained with increased safety and at less expense. When suspended-sediment surrogate data meet consensus accuracy criteria and appropriate sediment-record computation techniques are applied, these technologies have the potential to revolutionize the way fluvial-sediment data are collected, analyzed, and disseminated.
ERIC Educational Resources Information Center
von Davier, Alina A.
2012-01-01
Maintaining comparability of test scores is a major challenge faced by testing programs that have almost continuous administrations. Among the potential problems are scale drift and rapid accumulation of errors. Many standard quality control techniques for testing programs, which can effectively detect and address scale drift for small numbers of…
Continuously monitoring the parity of superconducting qubits in a 2D cQED architecture
NASA Astrophysics Data System (ADS)
Blok, Machiel; Flurin, Emmanuel; Livingston, William; Colless, James; Dove, Allison; Siddiqi, Irfan
Continuous measurements of joint qubit properties such as their parity can reveal insight into the collapse dynamics of entangled states and are a prerequisite for implementing continuous quantum error correction. Here it is crucial that the measurement collects no information other than the parity to avoid measurement induced dephasing. In a cQED architecture, a full-parity measurement can be implemented by strongly coupling two transmon qubits to a single high-Q planar resonator (χ >> κ). We will discuss the experimental implementation of this on-chip technique and the prospects to extend it to more qubits. This will allow us to monitor, in real-time, the projection into multi-partite entangled states and continuously detect errors on a logical qubit encoded in an entangled subspace. This work was supported by Army Research Office.
Buy, Xavier; Tok, Chung-Hong; Szwarc, Daniel; Bierry, Guillaume; Gangi, Afshin
2009-05-01
Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO(2) displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO(2) dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO(2) volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.
NASA Astrophysics Data System (ADS)
Kondrat'eva, O. E.; Roslyakov, P. V.; Burdyukov, D. A.; Khudolei, O. D.; Loktionov, O. A.
2017-10-01
According to Federal Law no. 219-FZ, dated July 21, 2014, all enterprises that have a significant negative impact on the environment shall continuously monitor and account emissions of harmful substances into the atmospheric air. The choice of measuring equipment that is included in continuous emission monitoring and accounting systems (CEM&ASs) is a complex technical problem; in particular, its solution requires a comparative analysis of gas analysis systems; each of these systems has its advantages and disadvantages. In addition, the choice of gas analysis systems for CEM&ASs should be maximally objective and not depend on preferences of separate experts and specialists. The technique of choosing gas analysis equipment that was developed in previous years at Moscow Power Engineering Institute (MPEI) has been analyzed and the applicability of the mathematical tool of a multiple criteria analysis to choose measuring equipment for the continuous emission monitoring and accounting system have been estimated. New approaches to the optimal choice of gas analysis equipment for systems of the continuous monitoring and accounting of harmful emissions from thermal power plants have been proposed, new criteria of evaluation of gas analysis systems have been introduced, and weight coefficients have been determined for these criteria. The results of this study served as a basis for the Preliminary National Standard of the Russian Federation "Best Available Technologies. Automated Systems of Continuous Monitoring and Accounting of Emissions of Harmful (Polluting) Substances from Thermal Power Plants into the Atmospheric Air. Basic Requirements," which was developed by the Moscow Power Engineering Institute, National Research University, in cooperation with the Council of Power Producers and Strategic Electric Power Investors Association and the All-Russia Research Institute for Materials and Technology Standardization.
Zurauskas, Mantas; Bradu, Adrian; Ferguson, Daniel R; Hammer, Daniel X; Podoleanu, Adrian
2016-03-01
This paper presents a novel instrument for biosciences, useful for studies of moving embryos. A dual sequential imaging/measurement channel is assembled via a closed-loop tracking architecture. The dual channel system can operate in two regimes: (i) single-point Doppler signal monitoring or (ii) fast 3-D swept source OCT imaging. The system is demonstrated for characterizing cardiac dynamics in Drosophila melanogaster larva. Closed loop tracking enables long term in vivo monitoring of the larvae heart without anesthetic or physical restraint. Such an instrument can be used to measure subtle variations in the cardiac behavior otherwise obscured by the larvae movements. A fruit fly larva (top) was continuously tracked for continuous remote monitoring. A heartbeat trace of freely moving larva (bottom) was obtained by a low coherence interferometry based doppler sensing technique. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Evaluation of performance of asphalt pavements constructed using intelligent compaction techniques.
DOT National Transportation Integrated Search
2014-10-01
The long-term performance of asphalt pavements depends on the quality of the subgrade and : asphalt layers. Intelligent compaction methods continuously monitor the modulus/stiffness of : subgrade and asphalt layers during compaction process and have ...
Lee, Yi-Hsuan; von Davier, Alina A
2013-07-01
Maintaining a stable score scale over time is critical for all standardized educational assessments. Traditional quality control tools and approaches for assessing scale drift either require special equating designs, or may be too time-consuming to be considered on a regular basis with an operational test that has a short time window between an administration and its score reporting. Thus, the traditional methods are not sufficient to catch unusual testing outcomes in a timely manner. This paper presents a new approach for score monitoring and assessment of scale drift. It involves quality control charts, model-based approaches, and time series techniques to accommodate the following needs of monitoring scale scores: continuous monitoring, adjustment of customary variations, identification of abrupt shifts, and assessment of autocorrelation. Performance of the methodologies is evaluated using manipulated data based on real responses from 71 administrations of a large-scale high-stakes language assessment.
Applying NISHIJIN historical textile technique for e-Textile.
Kuroda, Tomohiro; Hirano, Kikuo; Sugimura, Kazushige; Adachi, Satoshi; Igarashi, Hidetsugu; Ueshima, Kazuo; Nakamura, Hideo; Nambu, Masayuki; Doi, Takahiro
2013-01-01
The e-Textile is the key technology for continuous ambient health monitoring to increase quality of life of patients with chronic diseases. The authors introduce techniques of Japanese historical textile, NISHIJIN, which illustrate almost any pattern from one continuous yarn within the machine weaving process, which is suitable for mixed flow production. Thus, NISHIJIN is suitable for e-Textile production, which requires rapid prototyping and mass production of very complicated patterns. The authors prototyped and evaluated a few vests to take twelve-lead electrocardiogram. The result tells that the prototypes obtains electrocardiogram, which is good enough for diagnosis.
Evaluation of High-Precision Sensors in Structural Monitoring
Erol, Bihter
2010-01-01
One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i) evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii) providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers) and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA). Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant. PMID:22163499
A high-availability architecture for continuous monitoring of sleep disorders.
Iovanovici, Alexandru; Topirceanu, Alexandru; Udrescu, Mihai; Prodan, Lucian; Mihaicuta, Stefan
2015-01-01
We present a complete technical solution for continuously monitoring vital signs required for observing sleep apnoea events, one of the major sleep respiratory disorders. Based on industry accepted medical devices, we developed a GSM-based remote data acquisition and transfer module that is integrated via a set of web services into the server side of the application. The back-end is responsible with aggregating all the data, and, based on machine learning techniques, it provides a first level of filtering in order to warn about possible abnormalities. The proposed solution is currently under the test phase at the "Victor Babes" Hospital in Timisoara, Romania.
Coral lipids and environmental stress.
Harriott, V J
1993-04-01
Environmental monitoring of coral reefs is presently limited by difficulties in recognising coral stress, other than by monitoring coral mortality over time. A recent report described an experiment demonstrating that a measured lipid index declined in shaded corals. The technique described might have application in monitoring coral health, with a decline in coral lipid index as an indicator of coral stress. The application of the technique as a practical monitoring tool was tested for two coral species from the Great Barrier Reef. Consistent with the previous results, lipid index for Pocillopora damicornis initially declined over a period of three weeks in corals maintained in filtered seawater in the dark, indicating possible utilization of lipid stored as energy reserves. However, lipid index subsequently rose to near normal levels. In contrast, lipid index of Acropora formosa increased after four weeks in the dark in filtered seawater. The results showed considerable variability in lipid content between samples from the same colony. Results were also found to be dependent on fixation times and sample weight, introducing potential error into the practical application of the technique. The method as described would be unsuitable for monitoring environmental stress in corals, but the search for a practical method to monitor coral health should continue, given its importance in coral reef management.
Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel
2010-01-01
The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables. PMID:22399898
Domingo, Christian; Blanch, Lluis; Murias, Gaston; Luján, Manel
2010-01-01
The interest in measuring physiological parameters (especially arterial blood gases) has grown progressively in parallel to the development of new technologies. Physiological parameters were first measured invasively and at discrete time points; however, it was clearly desirable to measure them continuously and non-invasively. The development of intensive care units promoted the use of ventilators via oral intubation ventilators via oral intubation and mechanical respiratory variables were progressively studied. Later, the knowledge gained in the hospital was applied to out-of-hospital management. In the present paper we review the invasive and non-invasive techniques for monitoring respiratory variables.
Ocak, Işık; Kara, Atila; Ince, Can
2016-12-01
The clinical relevance of microcirculation and its bedside observation started gaining importance in the 1990s since the introduction of hand-held video microscopes. From then, this technology has been continuously developed, and its clinical relevance has been established in more than 400 studies. In this paper, we review the different types of video microscopes, their application techniques, the microcirculation of different organ systems, the analysis methods, and the software and scoring systems. The main focus of this review will be on the state-of-art technique, CytoCam-incident dark-field imaging, and the most recent technological and technical updates concerning microcirculation monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-01-01
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70–200 mg/dL), revealing high system performance for a wide glycemic state range (45–500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting. PMID:27669267
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
NASA Astrophysics Data System (ADS)
Holford, Karen M.; Eaton, Mark J.; Hensman, James J.; Pullin, Rhys; Evans, Sam L.; Dervilis, Nikolaos; Worden, Keith
2017-04-01
The acoustic emission (AE) phenomenon has many attributes that make it desirable as a structural health monitoring or non-destructive testing technique, including the capability to continuously and globally monitor large structures using a sparse sensor array and with no dependency on defect size. However, AE monitoring is yet to fulfil its true potential, due mainly to limitations in location accuracy and signal characterisation that often arise in complex structures with high levels of background noise. Furthermore, the technique has been criticised for a lack of quantitative results and the large amount of operator interpretation required during data analysis. This paper begins by introducing the challenges faced in developing an AE based structural health monitoring system and then gives a review of previous progress made in addresing these challenges. Subsequently an overview of a novel methodology for automatic detection of fatigue fractures in complex geometries and noisy environments is presented, which combines a number of signal processing techniques to address the current limitations of AE monitoring. The technique was developed for monitoring metallic landing gear components during pre-flight certification testing and results are presented from a full-scale steel landing gear component undergoing fatigue loading. Fracture onset was successfully identify automatically at 49,000 fatigue cycles prior to final failure (validated by the use of dye penetrant inspection) and the fracture position was located to within 10 mm of the actual location.
Randolph, Gregory W.; Barczynski, Marcin; Dionigi, Gianlorenzo; Wu, Che-Wei; Chiang, Feng-Yu; Machens, Andreas; Kamani, Dipti; Dralle, Henning
2016-01-01
The continuous intraoperative neural monitoring (CIONM) technique is increasingly acknowledged as a useful tool to recognize impending nerve injury and to abort the related manoeuvre to prevent nerve injury during thyroid surgery. CIONM provides valuable real-time information constantly, which is really useful during complex thyroid surgeries especially in the settings of unusual anatomy. Thus, CIONM overcomes the key methodological limitation inherent in intermittent nerve monitoring (IINOM); which is allowing the nerve to be at risk in between the stimulations. The clinically important combined electromyographic (EMG) event, indicative of impending recurrent laryngeal nerve (RLN) injury, prevents the majority of traction related injuries to the anatomically intact RLN enabling modification of the causative surgical manoeuvre in 80% of cases. These EMG changes can progress to loss of EMG signal with postoperative vocal cord palsy (VCP) if corrective action is not taken. As a further extension, CIONM also helps to identify intraoperative functional nerve recovery with restitution of amplitude to ≥50% of initial baseline; this allows continuing of resection of contralateral side. CIONM facilitates for early corrective action before permanent damage to the nerve has been done. CIONM is a recent but rapidly evolving technique, constantly being refined by various studies focusing on improvement in its implementation and interpretation, as well as on the elimination of the technical snags. PMID:28149807
Timely detection and monitoring of oil leakage by satellite optical data.
NASA Astrophysics Data System (ADS)
Grimaldi, C. S. L.; Coviello, I.; Lacava, T.; Pergola, N.; Tramutoli, V.
2009-04-01
Sea oil pollution can derive from different sources. Accidental release of oil into the oceans caused by "human errors" (tankers collisions and/or shipwrecks) or natural hazards (hurricanes, landslides, earthquakes) have remarkable ecological impact on maritime and coastal environments. Katrina Hurricane, for example, hitting oil and gas infrastructures off USA coasts caused the destruction of more than 100 platforms and the release into the sea of more than 10,000 gallons of crude oil. In order to reduce the environmental impact of such kind of technological hazards, timely detection and continuously updated information are fundamental. Satellite remote sensing can give a significant contribution in such a direction. Nowadays, SAR (Synthetic Aperture Radar) technology has been recognized as the most efficient for oil spill detection and mapping, thanks to the high spatial resolution and all-time/weather capability of the present operational sensors. Anyway, due to their current revisiting cycles, SAR systems cannot be profitably used for a rapid detection and for a continuous and near real-time monitoring of these phenomena. Until COSMO-Skymed SAR constellation, that will be able to improve SAR observational frequency, will not be fully operational, passive optical sensors on board meteorological satellites, thanks to their high temporal resolution, may represent a suitable alternative for early detection and continuous monitoring of oil spills, provided that adequate and reliable data analysis techniques exist. Recently, an innovative technique for oil spill detection and monitoring, based on the general Robust Satellite Techniques (RST) approach, has been proposed. It exploits the multi-temporal analysis of optical data acquired by both AVHRR (Advanced Very High Resolution Radiometer) and MODIS (Moderate Resolution Imaging Spectroradiometer) sensors in order to detect, automatically and timely, the presence of oil spill over the sea surface, trying to minimize the "false-detections" possibly caused by spurious effects (e.g. clouds). In this paper, preliminary results obtained applying the proposed methodology to different test-cases are shown and discussed.
Monitoring and modeling of ultrasonic wave propagation in crystallizing mixtures
NASA Astrophysics Data System (ADS)
Marshall, T.; Challis, R. E.; Tebbutt, J. S.
2002-05-01
The utility of ultrasonic compression wave techniques for monitoring crystallization processes is investigated in a study of the seeded crystallization of copper II sulfate pentahydrate from aqueous solution. Simple models are applied to predict crystal yield, crystal size distribution and the changing nature of the continuous phase. A scattering model is used to predict the ultrasonic attenuation as crystallization proceeds. Experiments confirm that modeled attenuation is in agreement with measured results.
NASA Astrophysics Data System (ADS)
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Hydrologic Monitoring in the Deep Subsurface to Support Repository Performance
NASA Astrophysics Data System (ADS)
Hubbell, J. M.; Heath, G. L.; Scott, C. L.
2007-12-01
The INL has installed and operated several vadose and ground water monitoring systems in arid and humid sites to depths of about 200m. Some of these systems have been in continuous operation for over 12 years. It is important that the systems be physically robust, simple, yet versatile enough that it can operate for extended time periods with little or no maintenance. Monitoring instruments are frequently installed and run to characterize the site, collect data during site operation, and continue to run for long-term stewardship, necessitating sensors that can be maintained or serviced. Sensors are carefully chosen based on the perceived data requirements over the life of the site. An emphasis is given on direct measurements such as tensiometers (portable and advanced), neutron probe, drain gauge, temperature, wells or sampling for fluids and gases. Other complementary data can include using TDR/capacitance, radiation detectors, and larger scale geophysical techniques (3-d resistivity and EM) for volumetric measurements. Commercially available instruments may have to be modified for their use at greater depths, to allow multiple instruments in a single borehole or to perform the intended monitoring function. Access tubes (some open at the bottom) can be placed to allow insertion of multiple sensors (radiation, neutron and portable sensors/samplers), future drilling/sampling and to install new instruments at a later time. The installation techniques and backfill materials must be chosen and the measurement technique tested to ensure representative data collection for the parameters of interest. The data collection system can be linked to climatic data (precipitation, barometric pressure, snow depth, runoff, surface water sources) that may influence the site's subsurface hydrology. The instruments are then connected to a real-time automated data collection system that collect, stores, and provides access to the data. These systems have been developed that allow easy access, automatic data quality checks with notification, processing, and presentation of the data in real time through the web. The systems can be designed to manipulate/test the system remotely. Data from several sites will be presented showing that continuous monitoring is necessary to detect rapid changes in the deep vadose zone and ground water at fractured rock sites.
Optical Drug Monitoring: Photoacoustic Imaging of Nanosensors to Monitor Therapeutic Lithium In Vivo
Cash, Kevin J.; Li, Chiye; Xia, Jun; Wang, Lihong V.; Clark, Heather A.
2015-01-01
Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes. PMID:25588028
Cash, Kevin J; Li, Chiye; Xia, Jun; Wang, Lihong V; Clark, Heather A
2015-02-24
Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal, we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes.
Depth discrimination in acousto-optic cerebral blood flow measurement simulation
NASA Astrophysics Data System (ADS)
Tsalach, A.; Schiffer, Z.; Ratner, E.; Breskin, I.; Zeitak, R.; Shechter, R.; Balberg, M.
2016-03-01
Monitoring cerebral blood flow (CBF) is crucial, as inadequate perfusion, even for relatively short periods of time, may lead to brain damage or even death. Thus, significant research efforts are directed at developing reliable monitoring tools that will enable continuous, bed side, simple and cost-effective monitoring of CBF. All existing non invasive bed side monitoring methods, which are mostly NIRS based, such as Laser Doppler or DCS, tend to underestimate CBF in adults, due to the indefinite effect of extra-cerebral tissues on the obtained signal. If those are to find place in day to day clinical practice, the contribution of extra-cerebral tissues must be eliminated and data from the depth (brain) should be extracted and discriminated. Recently, a novel technique, based on ultrasound modulation of light was developed for non-invasive, continuous CBF monitoring (termed ultrasound-tagged light (UTL or UT-NIRS)), and shown to correlate with readings of 133Xe SPECT and laser Doppler. We have assembled a comprehensive computerized simulation, modeling this acousto-optic technique in a highly scattering media. Using the combination of light and ultrasound, we show how depth information may be extracted, thus distinguishing between flow patterns taking place at different depths. Our algorithm, based on the analysis of light modulated by ultrasound, is presented and examined in a computerized simulation. Distinct depth discrimination ability is presented, suggesting that using such method one can effectively nullify the extra-cerebral tissues influence on the obtained signals, and specifically extract cerebral flow data.
Tomson, Todd T; Passman, Rod
Insertable cardiac monitors (ICMs) have provided clinicians with a superb tool for assessing infrequent or potentially asymptomatic arrhythmias. ICMs have shown their usefulness in the evaluation of unexplained syncope, providing high diagnostic yields in a cost-effective manner. While unexplained syncope continues to be the most common reason for their use, ICMs are increasingly being used for the monitoring of atrial fibrillation (AF). Recent trials have demonstrated that a substantial proportion of patients with cryptogenic stroke have AF detected only by the prolonged monitoring provided by ICMs. A particularly promising and emerging use for ICMs is in the management of anticoagulation in patients with known paroxysmal AF. The introduction in recent years of ICMs with automatic AF detection algorithms and continuous remote monitoring in combination with novel oral anticoagulants have opened the door for targeted anticoagulation guided by remote monitoring, a strategy that has recently shown promise in pilot studies of this technique. While further research is needed before official recommendations can be given, this use of ICMs opens exciting new possibilities for personalized medicine that could potentially reduce bleeding risk and improve quality of life in patients with atrial fibrillation.
DS Sentry: an acquisition ASIC for smart, micro-power sensing applications
NASA Astrophysics Data System (ADS)
Liobe, John; Fiscella, Mark; Moule, Eric; Balon, Mark; Bocko, Mark; Ignjatovic, Zeljko
2011-06-01
Unattended ground monitoring that combines seismic and acoustic information can be a highly valuable tool in intelligence gathering; however there are several prerequisites for this approach to be viable. The first is high sensitivity as well as the ability to discriminate real threats from noise and other spurious signals. By combining ground sensing with acoustic and image monitoring this requirement may be achieved. Moreover, the DS Sentry®provides innate spurious signal rejection by the "active-filtering" technique employed as well as embedding some basic statistical analysis. Another primary requirement is spatial and temporal coverage. The ideal is uninterrupted, long-term monitoring of an area. Therefore, sensors should be densely deployed and consume very little power. Furthermore, sensors must be inexpensive and easily deployed to allow dense placements in critical areas. The ADVIS DS Sentry®, which is a fully-custom integrated circuit that enables smart, micro-power monitoring of dynamic signals, is the foundation of the proposed system. The core premise behind this technology is the use of an ultra-low power front-end for active monitoring of dynamic signals in conjunction with a highresolution, Σ Δ-based analog-to-digital converter, which utilizes a novel noise rejection technique and is only employed when a potential threat has been detected. The DS Sentry® can be integrated with seismic accelerometers and microphones and user-programmed to continuously monitor for signals with specific signatures such as impacts, footsteps, excavation noise, vehicle-induced ground vibrations, or speech, while consuming only microwatts of power. This will enable up to several years of continuous monitoring on a single small battery while concurrently mitigating false threats.
NASA Astrophysics Data System (ADS)
Watlet, A.; Van Camp, M. J.; Poulain, A.; Hallet, V.; Rochez, G.; Quinif, Y.; Meus, P.; Kaufmann, O.; Francis, O.
2016-12-01
Karst systems are highly heterogeneous which makes their hydrology difficult to understand. Geophysical techniques offer non-invasive and integrative methods that help interpreting such systems as a whole. Among these techniques, gravimetry has been increasingly used in the last decade to characterize the hydrological behavior of complex systems, e.g. karst environments or volcanoes. We present a continuous microgravimetric monitoring of 3 years in the karstic area of Rochefort (Belgium), that shows multiple occurrences of caves and karstic features. The gravity record includes measurements of a GWR superconducting gravimeter, a Micro-g LaCoste gPhone and an absolute FG5 gravimeter. Together with meteorological measurements and a surface/in-cave hydrogeological monitoring, we were able to improve the knowledge of hydrological processes. On the one hand, the data allowed identifying seasonal groundwater content changes in the unsaturated zone of the karst area, most likely to be linked to temporary groundwater storage occurring in the most karstified layers closed to the surface. Combined with additional geological information, modelling of the gravity signal based on the vertical potential of the gravitational attraction was then particularly useful to estimate the seasonal recharge leading to the temporary subsurface groundwater storage. On the other hand, the gravity monitoring of flash floods occurring in deeper layers after intense rainfall events informed on the effective porosity gradient of the limestones. Modelling was then helpful to identify the hydrogeological role played by the cave galleries with respect to the hosting limestones during flash floods. These results are also compared with measurements of an in-cave gravimetric monitoring performed with a gPhone spring gravimeter. An Electrical Resistivity Tomography monitoring is also conducted at site and brings additional information useful to verify the interpretation made with the gravimetric monitoring.
DOT National Transportation Integrated Search
2002-03-01
As CFRP composites continue to gain acceptance in structural rehabilitation of deteriorating infrastructure, the consequent need for comprehensive and rapid in-situ quality assessment has arisen. Conditioned by the inevitable presence of material-, i...
USDA-ARS?s Scientific Manuscript database
Catechin (monomer), purified grape skin proanthocyanidin (polymer), and purified grape seed proanthocyanidin (polymer) underwent monitored accelerated oxidation under continuous oxygenation and UV light, at a constant 20 °C. Compounds were dissolved in model wine solutions with (and without) catecho...
Multimodal brain monitoring in fulminant hepatic failure
Paschoal Jr, Fernando Mendes; Nogueira, Ricardo Carvalho; Ronconi, Karla De Almeida Lins; de Lima Oliveira, Marcelo; Teixeira, Manoel Jacobsen; Bor-Seng-Shu, Edson
2016-01-01
Acute liver failure, also known as fulminant hepatic failure (FHF), embraces a spectrum of clinical entities characterized by acute liver injury, severe hepatocellular dysfunction, and hepatic encephalopathy. Cerebral edema and intracranial hypertension are common causes of mortality in patients with FHF. The management of patients who present acute liver failure starts with determining the cause and an initial evaluation of prognosis. Regardless of whether or not patients are listed for liver transplantation, they should still be monitored for recovery, death, or transplantation. In the past, neuromonitoring was restricted to serial clinical neurologic examination and, in some cases, intracranial pressure monitoring. Over the years, this monitoring has proven insufficient, as brain abnormalities were detected at late and irreversible stages. The need for real-time monitoring of brain functions to favor prompt treatment and avert irreversible brain injuries led to the concepts of multimodal monitoring and neurophysiological decision support. New monitoring techniques, such as brain tissue oxygen tension, continuous electroencephalogram, transcranial Doppler, and cerebral microdialysis, have been developed. These techniques enable early diagnosis of brain hemodynamic, electrical, and biochemical changes, allow brain anatomical and physiological monitoring-guided therapy, and have improved patient survival rates. The purpose of this review is to discuss the multimodality methods available for monitoring patients with FHF in the neurocritical care setting. PMID:27574545
NASA Astrophysics Data System (ADS)
Altunbek, Mine; Kelestemur, Seda; Culha, Mustafa
2015-12-01
Surface-enhanced Raman scattering (SERS) continues to strive to gather molecular level information from dynamic biological systems. It is our ongoing effort to utilize the technique for understanding of the biomolecular processes in living systems such as eukaryotic and prokaryotic cells. In this study, the technique is investigated to identify cell death mechanisms in 2D and 3D in vitro cell culture models, which is a very important process in tissue engineering and pharmaceutical applications. Second, in situ biofilm formation monitoring is investigated to understand how microorganisms respond to the environmental stimuli, which inferred information can be used to interfere with biofilm formation and fight against their pathogenic activity.
Assessing dry weather flow contribution in TSS and COD storm events loads in combined sewer systems.
Métadier, M; Bertrand-Krajewski, J L
2011-01-01
Continuous high resolution long term turbidity measurements along with continuous discharge measurements are now recognised as an appropriate technique for the estimation of in sewer total suspended solids (TSS) and Chemical Oxygen Demand (COD) loads during storm events. In the combined system of the Ecully urban catchment (Lyon, France), this technique is implemented since 2003, with more than 200 storm events monitored. This paper presents a method for the estimation of the dry weather (DW) contribution to measured total TSS and COD event loads with special attention devoted to uncertainties assessment. The method accounts for the dynamics of both discharge and turbidity time series at two minutes time step. The study is based on 180 DW days monitored in 2007-2008. Three distinct classes of DW days were evidenced. Variability analysis and quantification showed that no seasonal effect and no trend over the year were detectable. The law of propagation of uncertainties is applicable for uncertainties estimation. The method has then been applied to all measured storm events. This study confirms the interest of long term continuous discharge and turbidity time series in sewer systems, especially in the perspective of wet weather quality modelling.
NASA Astrophysics Data System (ADS)
Heise, H. Michael; Damm, Uwe; Kondepati, Venkata R.
2006-02-01
For clinical research, in-vivo blood glucose monitoring is an ongoing important topic to improve glycemic control in patients with non-adequate blood glucose regulation. Critically ill patients received much interest, since the intensive insulin therapy treatment, as established for diabetics, reduces mortality significantly. Despite the existence of commercially available, mainly amperometric biosensors, continued interest is in infrared spectroscopic techniques for reagent-free glucose monitoring. For stable long-term operation, avoiding also sensor recalibration, a bed-side device coupled to a micro-dialysis probe was developed for quasi-continuous glucose monitoring. Multivariate calibration is required for glucose concentration prediction due to the complex composition of dialysates from interstitial body fluid. Measurements were carried out with different test persons, each experiment lasting for more than 8 hours. Owing to low dialysis recovery rates, glucose concentrations in the dialysates were between 0.83 and 4.44 mM. Standard errors of prediction (SEP) obtained with Partial Least Squares (PLS) calibration and different cross-validation strategies were mainly between 0.13 and 0.18 mM based on either full interval data or specially selected spectral variables.
Self-calibration techniques of underwater gamma ray spectrometers.
Vlachos, D S
2005-01-01
In situ continuous monitoring of radioactivity in the water environment has many advantages compared to sampling and analysis techniques but a few shortcomings as well. Apart from the problems encountered in the assembly of the carrying autonomous systems, continuous operation some times alters the response function of the detectors. For example, the continuous operation of a photomultiplier tube results in a shift in the measured spectrum towards lower energies, making thus necessary the re-calibration of the detector. In this work, it is proved, that when measuring radioactivity in seawater, a photo peak around 50 keV will be always present in the measured spectrum. This peak is stable, depends only on the scattering rates of photons in seawater and, when it is detectable, can be used in conjunction with other peaks (40K and/or 208Tl) as a reference peak for the continuous calibration of the detector.
AMON: a wearable multiparameter medical monitoring and alert system.
Anliker, Urs; Ward, Jamie A; Lukowicz, Paul; Tröster, Gerhard; Dolveck, François; Baer, Michel; Keita, Fatou; Schenker, Eran B; Catarsi, Fabrizio; Coluccini, Luca; Belardinelli, Andrea; Shklarski, Dror; Alon, Menachem; Hirt, Etienne; Schmid, Rolf; Vuskovic, Milica
2004-12-01
This paper describes an advanced care and alert portable telemedical monitor (AMON), a wearable medical monitoring and alert system targeting high-risk cardiac/respiratory patients. The system includes continuous collection and evaluation of multiple vital signs, intelligent multiparameter medical emergency detection, and a cellular connection to a medical center. By integrating the whole system in an unobtrusive, wrist-worn enclosure and applying aggressive low-power design techniques, continuous long-term monitoring can be performed without interfering with the patients' everyday activities and without restricting their mobility. In the first two and a half years of this EU IST sponsored project, the AMON consortium has designed, implemented, and tested the described wrist-worn device, a communication link, and a comprehensive medical center software package. The performance of the system has been validated by a medical study with a set of 33 subjects. The paper describes the main concepts behind the AMON system and presents details of the individual subsystems and solutions as well as the results of the medical validation.
Hybrid CARS for Non-Invasive Blood Glucose Monitoring
NASA Astrophysics Data System (ADS)
Wang, Xi; Pestov, Dmitry; Zhang, Aihua; Murawski, Robert; Sokolov, Alexei; Welch, George; Laane, Jaan; Scully, Marlan
2007-10-01
We develop a spectroscopy technique that combines the advantages of both the frequency-resolved coherent anti-Stokes Raman scattering (CARS) and the time-resolved CARS. We use broadband preparation pulses to get an instantaneous coherent excitation of multiplex molecular vibration levels and subsequent optically shaped time-delayed narrowband probing pulse to detect these vibrations. This technique can suppress the nonresonant background and retrieve the molecular fingerprint signal efficiently and rapidly. We employ this technique to glucose detection, the final goal of which is accurate, non-invasive (i.e. painless) and continuous monitoring of blood glucose concentration in the Diabetes diagnosis to replace the current glucose measurement process, which requires painful fingerpricks and therefore cannot be performed more than a few times a day. We have gotten the CARS spectra of glucose aqueous solution down to 2 mM.
Pickwell, Andrew J; Dorey, Robert A; Mba, David
2011-09-01
Monitoring the condition of complex engineering structures is an important aspect of modern engineering, eliminating unnecessary work and enabling planned maintenance, preventing failure. Acoustic emissions (AE) testing is one method of implementing continuous nondestructive structural health monitoring. A novel thick-film (17.6 μm) AE sensor is presented. Lead zirconate titanate thick films were fabricated using a powder/sol composite ink deposition technique and mechanically patterned to form a discrete thick-film piezoelectric AE sensor. The thick-film sensor was benchmarked against a commercial AE device and was found to exhibit comparable responses to simulated acoustic emissions.
Transcranial Doppler: Techniques and advanced applications: Part 2
Sharma, Arvind K.; Bathala, Lokesh; Batra, Amit; Mehndiratta, Man Mohan; Sharma, Vijay K.
2016-01-01
Transcranial Doppler (TCD) is the only diagnostic tool that can provide continuous information about cerebral hemodynamics in real time and over extended periods. In the previous paper (Part 1), we have already presented the basic ultrasound physics pertaining to TCD, insonation methods, and various flow patterns. This article describes various advanced applications of TCD such as detection of right-to-left shunt, emboli monitoring, vasomotor reactivity (VMR), monitoring of vasospasm in subarachnoid hemorrhage (SAH), monitoring of intracranial pressure, its role in stoke prevention in sickle cell disease, and as a supplementary test for confirmation of brain death. PMID:27011639
Deformation Monitoring and Analysis of Lsp Landslide Based on Gbinsar
NASA Astrophysics Data System (ADS)
Zhou, L.; Guo, J.; Yang, F.
2018-05-01
Monitoring and analyzing the deformation of the river landslide in city to master the deformation law of landslide, which is an important means of landslide safety assessment. In this paper, aiming at the stability of the Liu Sha Peninsula Landslide during its strengthening process after the landslide disaster. Continuous and high precision deformation monitoring of the landslide was carried out by GBInSAR technique. Meanwhile, the two-dimensional deformation time series pictures of the landslide body were retrieved by the time series analysis method. The deformation monitoring and analysis results show that the reinforcement belt on the landslide body was basically stable and the deformation of most PS points on the reinforcement belt was within 1 mm. The deformation of most areas on the landslide body was basically within 4 mm, and the deformation presented obvious nonlinear changes. GBInSAR technique can quickly and effectively obtain the entire deformation information of the river landslide and the evolution process of deformation.
NASA Astrophysics Data System (ADS)
Zhao, Chaoying; Zhang, Qin; He, Yang; Peng, Jianbing; Yang, Chengsheng; Kang, Ya
2016-04-01
Small baseline subsets interferometric synthetic aperture radar technique is analyzed to detect and monitor the loess landslide in the southern bank of the Jinghe River, Shaanxi province, China. Aiming to achieve the accurate preslide time-series deformation results over small spatial scale and abrupt temporal deformation loess landslide, digital elevation model error, coherence threshold for phase unwrapping, and quality of unwrapping interferograms must be carefully checked in advance. In this experience, land subsidence accompanying a landslide with the distance <1 km is obtained, which gives a sound precursor for small-scale loess landslide detection. Moreover, the longer and continuous land subsidence has been monitored while deformation starting point for the landslide is successfully inverted, which is key to monitoring the similar loess landslide. In addition, the accelerated landslide deformation from one to two months before the landslide can provide a critical clue to early warning of this kind of landslide.
NASA Astrophysics Data System (ADS)
Talakokula, Visalakshi; Bhalla, Suresh; Gupta, Ashok
2018-01-01
Concrete is the most widely used material in civil engineering construction. Its life begins when the hydration process is activated after mixing the cement granulates with water. In this paper, a non-dimensional hydration parameter, obtained from piezoelectric ceramic (PZT) patches bonded to rebars embedded inside concrete, is employed to monitor the early age hydration of concrete. The non-dimensional hydration parameter is derived from the equivalent stiffness determined from the piezo-impedance transducers using the electro-mechanical impedance (EMI) technique. The focus of the study is to monitor the hydration process of cementitious materials commencing from the early hours and continue till 28 days using single non-dimensional parameter. The experimental results show that the proposed piezo-based non-dimensional hydration parameter is very effective in monitoring the early age hydration, as it has been derived from the refined structural impedance parameters, obtained by eliminating the PZT contribution, and using both the real and imaginary components of the admittance signature.
NASA Astrophysics Data System (ADS)
Davies, N.; Davies-Shaw, D.; Shaw, J. D.
2007-02-01
We report firsthand on innovative developments in non-invasive, biophotonic techniques for a wide range of diagnostic, imaging and treatment options, including the recognition and quantification of cancerous, pre-cancerous cells and chronic inflammatory conditions. These techniques have benefited from the ability to target the affected site by both monochromatic light and broad multiple wavelength spectra. The employment of such wavelength or color-specific properties embraces the fluorescence stimulation of various photosensitizing drugs, and the instigation and detection of identified fluorescence signatures attendant upon laser induced fluorescence (LIF) phenomena as transmitted and propagated by precancerous, cancerous and normal tissue. In terms of tumor imaging and therapeutic and treatment options, we have exploited the abilities of various wavelengths to penetrate to different depths, through different types of tissues, and have explored quantifiable absorption and reflection characteristics upon which diagnostic assumptions can be reliably based and formulated. These biophotonic-based diagnostic, sensing and imaging techniques have also benefited from, and have been further enhanced by, the integrated ability to provide various power levels to be employed at various stages in the procedure. Applications are myriad, including non-invasive, non destructive diagnosis of in vivo cell characteristics and functions; light-based tissue analysis; real-time monitoring and mapping of brain function and of tumor growth; real time monitoring of the surgical completeness of tumor removal during laser-imaged/guided brain resection; diagnostic procedures based on fluorescence life-time monitoring, the monitoring of chronic inflammatory conditions (including rheumatoid arthritis), and continuous blood glucose monitoring in the control of diabetes.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) The extent to which the program would involve innovative teaching techniques; (3) The availability of... and teaching and is allowed to participate in the planning, organization, operation, and evaluation of... program; (10) The adequacy of the methods for monitoring and evaluating the program on a continuing basis...
Code of Federal Regulations, 2012 CFR
2012-10-01
...) The extent to which the program would involve innovative teaching techniques; (3) The availability of... and teaching and is allowed to participate in the planning, organization, operation, and evaluation of... program; (10) The adequacy of the methods for monitoring and evaluating the program on a continuing basis...
Code of Federal Regulations, 2014 CFR
2014-10-01
...) The extent to which the program would involve innovative teaching techniques; (3) The availability of... and teaching and is allowed to participate in the planning, organization, operation, and evaluation of... program; (10) The adequacy of the methods for monitoring and evaluating the program on a continuing basis...
Slope stability radar for monitoring mine walls
NASA Astrophysics Data System (ADS)
Reeves, Bryan; Noon, David A.; Stickley, Glen F.; Longstaff, Dennis
2001-11-01
Determining slope stability in a mining operation is an important task. This is especially true when the mine workings are close to a potentially unstable slope. A common technique to determine slope stability is to monitor the small precursory movements, which occur prior to collapse. The slope stability radar has been developed to remotely scan a rock slope to continuously monitor the spatial deformation of the face. Using differential radar interferometry, the system can detect deformation movements of a rough wall with sub-millimeter accuracy, and with high spatial and temporal resolution. The effects of atmospheric variations and spurious signals can be reduced via signal processing means. The advantage of radar over other monitoring techniques is that it provides full area coverage without the need for mounted reflectors or equipment on the wall. In addition, the radar waves adequately penetrate through rain, dust and smoke to give reliable measurements, twenty-four hours a day. The system has been trialed at three open-cut coal mines in Australia, which demonstrated the potential for real-time monitoring of slope stability during active mining operations.
NASA Astrophysics Data System (ADS)
Lösler, Michael; Haas, Rüdiger; Eschelbach, Cornelia
2013-08-01
The Global Geodetic Observing System (GGOS) requires sub-mm accuracy, automated and continual determinations of the so-called local tie vectors at co-location stations. Co-location stations host instrumentation for several space geodetic techniques and the local tie surveys involve the relative geometry of the reference points of these instruments. Thus, these reference points need to be determined in a common coordinate system, which is a particular challenge for rotating equipment like radio telescopes for geodetic Very Long Baseline Interferometry. In this work we describe a concept to achieve automated and continual determinations of radio telescope reference points with sub-mm accuracy. We developed a monitoring system, including Java-based sensor communication for automated surveys, network adjustment and further data analysis. This monitoring system was tested during a monitoring campaign performed at the Onsala Space Observatory in the summer of 2012. The results obtained in this campaign show that it is possible to perform automated determination of a radio telescope reference point during normal operations of the telescope. Accuracies on the sub-mm level can be achieved, and continual determinations can be realized by repeated determinations and recursive estimation methods.
NASA Astrophysics Data System (ADS)
Zhu, Zhengfan; Gan, Qingbo; Yang, Xin; Gao, Yang
2017-08-01
We have developed a novel continuation technique to solve optimal bang-bang control for low-thrust orbital transfers considering the first-order necessary optimality conditions derived from Lawden's primer vector theory. Continuation on the thrust amplitude is mainly described in this paper. Firstly, a finite-thrust transfer with an ;On-Off-On; thrusting sequence is modeled using a two-impulse transfer as initial solution, and then the thrust amplitude is decreased gradually to find an optimal solution with minimum thrust. Secondly, the thrust amplitude is continued from its minimum value to positive infinity to find the optimal bang-bang control, and a thrust switching principle is employed to determine the control structure by monitoring the variation of the switching function. In the continuation process, a bifurcation of bang-bang control is revealed and the concept of critical thrust is proposed to illustrate this phenomenon. The same thrust switching principle is also applicable to the continuation on other parameters, such as transfer time, orbital phase angle, etc. By this continuation technique, fuel-optimal orbital transfers with variable mission parameters can be found via an automated algorithm, and there is no need to provide an initial guess for the costate variables. Moreover, continuation is implemented in the solution space of bang-bang control that is either optimal or non-optimal, which shows that a desired solution of bang-bang control is obtained via continuation on a single parameter starting from an existing solution of bang-bang control. Finally, numerical examples are presented to demonstrate the effectiveness of the proposed continuation technique. Specifically, this continuation technique provides an approach to find multiple solutions satisfying the first-order necessary optimality conditions to the same orbital transfer problem, and a continuation strategy is presented as a preliminary approach for solving the bang-bang control of many-revolution orbital transfers.
Microfabricated fuel heating value monitoring device
Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM
2010-05-04
A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.
Fatigue crack monitoring with coupled piezoelectric film acoustic emission sensors
NASA Astrophysics Data System (ADS)
Zhou, Changjiang
Fatigue-induced cracking is a commonly seen problem in civil infrastructures reaching their original design life. A number of high-profile accidents have been reported in the past that involved fatigue damage in structures. Such incidences often happen without prior warnings due to lack of proper crack monitoring technique. In order to detect and monitor the fatigue crack, acoustic emission (AE) technique, has been receiving growing interests recently. AE can provide continuous and real-time monitoring data on damage progression in structures. Piezoelectric film AE sensor measures stress-wave induced strain in ultrasonic frequency range and its feasibility for AE signal monitoring has been demonstrated recently. However, extensive work in AE monitoring system development based on piezoelectric film AE sensor and sensor characterization on full-scale structures with fatigue cracks, have not been done. A lack of theoretical formulations for understanding the AE signals also hinders the use of piezoelectric film AE sensors. Additionally, crack detection and source localization with AE signals is a very important area yet to be explored for this new type of AE sensor. This dissertation presents the results of both analytical and experimental study on the signal characteristics of surface stress-wave induced AE strain signals measured by piezoelectric film AE sensors in near-field and an AE source localization method based on sensor couple theory. Based on moment tensor theory, generalized expression for AE strain signal is formulated. A special case involving the response of piezoelectric film AE sensor to surface load is also studied, which could potentially be used for sensor calibration of this type of sensor. A new concept of sensor couple theory based AE source localization technique is proposed and validated with both simulated and experimental data from fatigue test and field monitoring. Two series of fatigue tests were conducted to perform fatigue crack monitoring on large-scale steel test specimens using piezoelectric film AE sensors. Continuous monitoring of fatigue crack growth in steel structures is demonstrated in these fatigue test specimens. The use of piezoelectric film AE sensor for field monitoring of existing fatigue crack is also demonstrated in a real steel I-girder bridge located in Maryland. The sensor couple theory based AE source localization is validated using a limited number of piezoelectric film AE sensor data from both fatigue test specimens and field monitoring bridge. Through both laboratory fatigue test and field monitoring of steel structures with active fatigue cracks, the signal characteristics of piezoelectric film AE sensor have been studied in real-world environment.
Noninvasive oxygen monitoring techniques.
Wahr, J A; Tremper, K K
1995-01-01
As this article demonstrates, tremendous progress has been made in the techniques of oxygen measurement and monitoring over the past 50 years. From the early developments during and after World War II, to the most recent applications of solid state and microprocessor technology today, every patient in a critical care situation will have several continuous measurements of oxygenation applied simultaneously. Information therefore is available readily to alert personnel of acute problems and to guide appropriate therapy. The majority of effort to date has been placed on measuring oxygenation of arterial or venous blood. The next generation of devices will attempt to provide information about living tissue. Unlike the devices monitoring arterial or venous oxygen content, no "gold standards" exist for tissue oxygenation, so calibration will be difficult, as will interpretation of the data provided. The application of these devices ultimately may lead to a much better understanding of how disease (and the treatment of disease) alters the utilization of oxygen by the tissues.
Monitoring Neural Activity with Bioluminescence during Natural Behavior
Naumann, Eva A.; Kampff, Adam R.; Prober, David A.; Schier, Alexander F.; Engert, Florian
2010-01-01
Existing techniques for monitoring neural activity in awake, freely behaving vertebrates are invasive and difficult to target to genetically identified neurons. Here we describe the use of bioluminescence to non-invasively monitor the activity of genetically specified neurons in freely behaving zebrafish. Transgenic fish expressing the Ca2+-sensitive photoprotein GFP-apoAequorin (GA) in most neurons generated large and fast bioluminescent signals related to neural activity, neuroluminescence, that could be recorded continuously for many days. To test the limits of this technique, GA was specifically targeted to the hypocretin-positive neurons of the hypothalamus. We found that neuroluminescence generated by this group of ~20 neurons was associated with periods of increased locomotor activity and identified two classes of neural activity corresponding to distinct swim latencies. Thus, our neuroluminescence assay can report, with high temporal resolution and sensitivity, the activity of small subsets of neurons during unrestrained behavior. PMID:20305645
NASA Astrophysics Data System (ADS)
Delvecchio, S.; Bonfiglio, P.; Pompoli, F.
2018-01-01
This paper deals with the state-of-the-art strategies and techniques based on vibro-acoustic signals that can monitor and diagnose malfunctions in Internal Combustion Engines (ICEs) under both test bench and vehicle operating conditions. Over recent years, several authors have summarized what is known in critical reviews mainly focused on reciprocating machines in general or on specific signal processing techniques: no attempts to deal with IC engine condition monitoring have been made. This paper first gives a brief summary of the generation of sound and vibration in ICEs in order to place further discussion on fault vibro-acoustic diagnosis in context. An overview of the monitoring and diagnostic techniques described in literature using both vibration and acoustic signals is also provided. Different faulty conditions are described which affect combustion, mechanics and the aerodynamics of ICEs. The importance of measuring acoustic signals, as opposed to vibration signals, is due since the former seem to be more suitable for implementation on on-board monitoring systems in view of their non-intrusive behaviour, capability in simultaneously capturing signatures from several mechanical components and because of the possibility of detecting faults affecting airborne transmission paths. In view of the recent needs of the industry to (-) optimize component structural durability adopting long-life cycles, (-) verify the engine final status at the end of the assembly line and (-) reduce the maintenance costs monitoring the ICE life during vehicle operations, monitoring and diagnosing system requests are continuously growing up. The present review can be considered a useful guideline for test engineers in understanding which types of fault can be diagnosed by using vibro-acoustic signals in sufficient time in both test bench and operating conditions and which transducer and signal processing technique (of which the essential background theory is here reported) could be considered the most reliable and informative to be implemented for the fault in question.
Fabric-based Pressure Sensor Array for Decubitus Ulcer Monitoring
Chung, Philip; Rowe, Allison; Etemadi, Mozziyar; Lee, Hanmin; Roy, Shuvo
2015-01-01
Decubitus ulcers occur in an estimated 2.5 million Americans each year at an annual cost of $11 billion to the U.S. health system. Current screening and prevention techniques for assessing risk for decubitus ulcer formation and repositioning patients every 1–2 hours are labor-intensive and can be subjective. We propose use of a Bluetooth-enabled fabric-based pressure sensor array as a simple tool to objectively assess and continuously monitor decubitus ulcer risk. PMID:24111232
Biological water quality monitoring using chemiluminescent and bioluminescent techniques
NASA Technical Reports Server (NTRS)
Thomas, R. R.
1978-01-01
Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.
Analyzing the value of monitoring duodenal mucosal perfusion using photoplethysmography.
Fink, Mitchell P
2014-10-13
Photoplethysmography (PPG) is a technique that permits noninvasive measurement of changes in the volume of tissues. A novel device uses PPG to assess changes in duodenal mucosal perfusion. When tested in septic piglets, data obtained using this device correlate with the blood lactate concentration and duodenal serosal microvascular blood flow as measured with a laser Doppler flowmeter. This new PPG-based approach for continuously monitoring gut mucosal perfusion warrants further development, leading to prospective clinical trials in patients.
The potential risk of human exposure from an accidental or intentional release of CWAs into a civilian population continues to drive the need for screening and monitoring techniques for these compounds. In particular, rapid and reliable methods for detecting CWAs such as the nitr...
A nuclear scanning method for estimating wear level nonuniformities
NASA Astrophysics Data System (ADS)
Ivanov, E. A.; Pascovici, G.; Racolta, P. M.
1993-09-01
The residual radioactivity measuring method has been upgraded to estimate wear level nonuniformities in the circumference of a piston ring after a certain working time in the combustion engine testing bench. The piston ring was irradiated by the thin layer activation (TLA) technique and its radioactivity was continuously monitored.
Mobile Technology to Support the Interactive Classroom
ERIC Educational Resources Information Center
Fardoun, Habib M.; Awada, Hachem
2017-01-01
At the current classrooms, teachers continue using traditional techniques for monitoring the class. However, there are more participation of mobile devices, and concretely, the tablets. In addition, the network access by both students and teachers in daily life is something usual and a routine work. For this reason, the authors propose the…
The Effects of Self-Management Training on Academic Performance.
ERIC Educational Resources Information Center
Dean, Mark R.; And Others
1983-01-01
Self-management techniques--e.g., self-monitoring and self-recording--designed to increase the amount of time a student studies had positive results in this study involving undergraduate psychology students. Increases of one letter grade were obtained, and the majority of the students continued use of the methods. (RM)
Okamura, Naomi; Kobayashi, Yo; Sugano, Shigeki; Fujie, Masakatsu G
2017-07-01
Static stretching is widely performed to decrease muscle tone as a part of rehabilitation protocols. Finding out the optimal duration of static stretching is important to minimize the time required for rehabilitation therapy and it would be helpful for maintaining the patient's motivation towards daily rehabilitation tasks. Several studies have been conducted for the evaluation of static stretching; however, the recommended duration of static stretching varies widely between 15-30 s in general, because the traditional methods for the assessment of muscle tone do not monitor the continuous change in the target muscle's state. We have developed a method to monitor the viscoelasticity of one muscle continuously during static stretching, using a wearable indentation tester. In this study, we investigated a suitable signal processing method to detect the time required to change the muscle tone, utilizing the data collected using a wearable indentation tester. By calculating a viscoelastic index with a certain time window, we confirmed that the stretching duration required to bring about a decrease in muscle tone could be obtained with an accuracy in the order of 1 s.
Rumbold, P L S; Dodd-Reynolds, C J; Stevenson, E
2013-10-01
Electronic capture of free-living subjective appetite data can provide a more reliable alternative to traditional pen and paper visual analogue scales (P&P VAS), whilst reducing researcher workload. Consequently, the aim of this study was to explore the agreement between P&P VAS and a wristwatch-based electronic appetite rating system known as the PRO-Diary© technique, for monitoring free-living appetite sensations in 7-10 year old children. On one occasion, using a within-subject design, the 12 children (n=6 boys; n=6 girls) recorded their subjective appetite (hunger, prospective food consumption, and fullness), at two time points before lunch (11:30 and 12:00) and every 60 min thereafter until 21:00. The agreement between the P&P VAS and PRO-Diary© technique was explored using 95% limits of agreement and 95% confidence intervals (95% CI) calculated using the Bland and Altman (1986) technique. For hunger, prospective food consumption and fullness, the 95% limits of agreement were -1±25 mm (95% CI: lower limit -8mm; upper limit +6mm), 0±21 mm (95% CI: lower limit -6mm; upper limit +6mm) and -6±24 mm (95% CI: lower limit -14 mm; upper limit +1mm), respectively. Given the advantages associated with electronic data capture (inexpensive; integrated alarm; data easily downloaded), we conclude that the PRO-Diary© technique is an equivalent method to employ when continuously monitoring free-living appetite sensations in 7-10 year old children, but should not be used interchangeably with P&P VAS. Copyright © 2013 Elsevier Ltd. All rights reserved.
Relative velocity change measurement based on seismic noise analysis in exploration geophysics
NASA Astrophysics Data System (ADS)
Corciulo, M.; Roux, P.; Campillo, M.; Dubuq, D.
2011-12-01
Passive monitoring techniques based on noise cross-correlation analysis are still debated in exploration geophysics even if recent studies showed impressive performance in seismology at larger scale. Time evolution of complex geological structure using noise data includes localization of noise sources and measurement of relative velocity variations. Monitoring relative velocity variations only requires the measurement of phase shifts of seismic noise cross-correlation functions computed for successive time recordings. The existing algorithms, such as the Stretching and the Doublet, classically need great efforts in terms of computation time, making them not practical when continuous dataset on dense arrays are acquired. We present here an innovative technique for passive monitoring based on the measure of the instantaneous phase of noise-correlated signals. The Instantaneous Phase Variation (IPV) technique aims at cumulating the advantages of the Stretching and Doublet methods while proposing a faster measurement of the relative velocity change. The IPV takes advantage of the Hilbert transform to compute in the time domain the phase difference between two noise correlation functions. The relative velocity variation is measured through the slope of the linear regression of the phase difference curve as a function of correlation time. The large amount of noise correlation functions, classically available at exploration scale on dense arrays, allows for a statistical analysis that further improves the precision of the estimation of the velocity change. In this work, numerical tests first aim at comparing the IPV performance to the Stretching and Doublet techniques in terms of accuracy, robustness and computation time. Then experimental results are presented using a seismic noise dataset with five days of continuous recording on 397 geophones spread on a ~1 km-squared area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Fulin; Department of Materials Science and Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7; Zurob, Hatem S., E-mail: zurobh@mcmaster.ca
In situ electrical resistivity monitoring technique was employed to continuously evaluate the precipitate evolution of an Al–Zn–Mg–Cu-based commercial alloy during typical artificial aging treatments. The effects of artificial aging on the precipitates stability during non-isothermal heat treatments were also explored. Conventional hardness test, transmission electron microscopy and differential scanning calorimetry were also adopted to verify the electrical resistivity results. The results indicated that both the precipitation process and its timely rate could be followed by the monitored electrical resistivity during artificial aging treatments. The electrical resistivity results gave overall information on continuous precipitation and dissolution processes, especially under high heatingmore » rates. Samples artificial aging heat treated at 120 °C for 24 h followed by aging at 150 °C for 24 h presented more stable state and coarser precipitates than the samples only artificial aging heat treated at 120 °C for 24 h or triple artificial aging heat treated at 120 °C/24 h + 195 °C/15 min + 120 °/24 h. While the incoherent η precipitates in the samples artificial aging heat treated at 120 °C for 24 h followed by aging at 150 °C for 24 h were more easiness to coarsening and dissolve during non-isothermal heat treatments as well. - Highlights: • In situ electrical resistivity monitoring technique was employed on an Al-Zn-Mg-Cu alloy. • The precipitate evolution during typical artificial aging treatments was studied. • The precipitate stability during non-isothermal heat treatments was explored. • The electrical resistivity wonderfully monitored continuous precipitation and dissolution. • The alloy submitted to a T7 treatment presents a more stable state during heating due to incoherent η precipitates.« less
Sonification of network traffic flow for monitoring and situational awareness
2018-01-01
Maintaining situational awareness of what is happening within a computer network is challenging, not only because the behaviour happens within machines, but also because data traffic speeds and volumes are beyond human ability to process. Visualisation techniques are widely used to present information about network traffic dynamics. Although they provide operators with an overall view and specific information about particular traffic or attacks on the network, they often still fail to represent the events in an understandable way. Also, because they require visual attention they are not well suited to continuous monitoring scenarios in which network administrators must carry out other tasks. Here we present SoNSTAR (Sonification of Networks for SiTuational AwaReness), a real-time sonification system for monitoring computer networks to support network administrators’ situational awareness. SoNSTAR provides an auditory representation of all the TCP/IP traffic within a network based on the different traffic flows between between network hosts. A user study showed that SoNSTAR raises situational awareness levels by enabling operators to understand network behaviour and with the benefit of lower workload demands (as measured by the NASA TLX method) than visual techniques. SoNSTAR identifies network traffic features by inspecting the status flags of TCP/IP packet headers. Combinations of these features define particular traffic events which are mapped to recorded sounds to generate a soundscape that represents the real-time status of the network traffic environment. The sequence, timing, and loudness of the different sounds allow the network to be monitored and anomalous behaviour to be detected without the need to continuously watch a monitor screen. PMID:29672543
Sonification of network traffic flow for monitoring and situational awareness.
Debashi, Mohamed; Vickers, Paul
2018-01-01
Maintaining situational awareness of what is happening within a computer network is challenging, not only because the behaviour happens within machines, but also because data traffic speeds and volumes are beyond human ability to process. Visualisation techniques are widely used to present information about network traffic dynamics. Although they provide operators with an overall view and specific information about particular traffic or attacks on the network, they often still fail to represent the events in an understandable way. Also, because they require visual attention they are not well suited to continuous monitoring scenarios in which network administrators must carry out other tasks. Here we present SoNSTAR (Sonification of Networks for SiTuational AwaReness), a real-time sonification system for monitoring computer networks to support network administrators' situational awareness. SoNSTAR provides an auditory representation of all the TCP/IP traffic within a network based on the different traffic flows between between network hosts. A user study showed that SoNSTAR raises situational awareness levels by enabling operators to understand network behaviour and with the benefit of lower workload demands (as measured by the NASA TLX method) than visual techniques. SoNSTAR identifies network traffic features by inspecting the status flags of TCP/IP packet headers. Combinations of these features define particular traffic events which are mapped to recorded sounds to generate a soundscape that represents the real-time status of the network traffic environment. The sequence, timing, and loudness of the different sounds allow the network to be monitored and anomalous behaviour to be detected without the need to continuously watch a monitor screen.
Jan, Saber; Northington, Frances J; Parkinson, Charlamaine M; Stafstrom, Carl E
2017-01-01
Electroencephalogram (EEG) monitoring techniques for neonatal hypoxia-ischemia (HI) are evolving over time, and the specific type of EEG utilized could influence seizure diagnosis and management. We examined whether the type of EEG performed affected seizure treatment decisions (e.g., the choice and number of antiseizure drugs [ASDs]) in therapeutic hypothermia-treated neonates with HI from 2007 to 2015 in the Johns Hopkins Hospital Neonatal Intensive Care Unit. During this period, 3 different EEG monitoring protocols were utilized: Period 1 (2007-2009), single, brief conventional EEG (1 h duration) at a variable time during therapeutic hypothermia treatment, i.e., ordered when a seizure was suspected; Period 2 (2009-2013), single, brief conventional EEG followed by amplitude-integrated EEG for the duration of therapeutic hypothermia treatment and another brief conventional EEG after rewarming; and Period 3 (2014-2015), continuous video-EEG (cEEG) for the duration of therapeutic hypothermia treatment (72 h) plus for an additional 12 h during and after rewarming. One hundred and sixty-two newborns were included in this retrospective cohort study. As a function of the type and duration of EEG monitoring, we assessed the risk (likelihood) of receiving no ASD, at least 1 ASD, or ≥2 ASDs. We found that the risk of a neonate being prescribed an ASD was 46% less during Period 3 (cEEG) than during Period 1 (brief conventional EEG only) (95% CI 6-69%, p = 0.03). After adjusting for initial EEG and MRI results, compared with Period 1, there was a 38% lower risk of receiving an ASD during Period 2 (95% CI: 9-58%, p = 0.02) and a 67% lower risk during Period 3 (95% CI: 23-86%, p = 0.01). The risk ratio of receiving ≥2 ASDs was not significantly different across the 3 periods. In conclusion, in addition to the higher sensitivity and specificity of continuous video-EEG monitoring, fewer infants are prescribed an ASD when undergoing continuous forms of EEG monitoring (aEEG or cEEG) than those receiving conventional EEG. We recommend that use of continuous video-EEG be considered whenever possible, both to treat seizures more specifically and to avoid overtreatment. © 2017 S. Karger AG, Basel.
Hayes, Robert
2004-10-01
In most nuclear facilities, fixed air samplers and sometimes portable air samplers are used where some probability of a release exists but is not expected, and so the added expense and effort of using a continuous air monitor is not deemed justified. When a release is suspected, naturally occurring radioactive material buildup on the filter typically prevents any quantitative measurements within the first day or so. Likewise, outdoor air measurements suffer from the same limitations (such as those taken during the Los Alamos fires) and so any rapid quantifiable measurements of fixed air sampler/portable air sampler filters which are technically defendable (even though conservative) are of use. The technique presented here is only intended for use in routine health physics survey applications and does not presently appear to be appropriate for sub pico Curie activity determinations. This study evaluates the utility of using a portable continuous air monitor as an alpha spectrometer to make transuranic activity determinations of samples using both the built in algorithm for air monitoring and a simple region of interest analysis. All samples evaluated were from air sample filters taken using a portable air sampler. Samples were taken over many months to quantify effects from natural variation in radon progeny activity distributions.
Field evaluation of Fourier transform infrared continuous emissions monitoring (FTIR CEM) systems
NASA Astrophysics Data System (ADS)
Dunder, Thomas A.; Geyer, Thomas J.; Kinner, Laura L.; Plummer, Grant M.
1995-02-01
Recent environmental regulations, including the Clean Air Act and the Enhanced Monitoring Regulations, may require continuous emissions monitoring (CEM) of hazardous air pollutants (HAPs). A promising technique for this application is Fourier transform infrared spectroscopy (FTIR). FTIR spectroscopy can, in principle, be used to monitor virtually any gas phase species. Two evaluations of FTIR CEM systems are discussed. The first study, performed in 1993 - 94, compared two FTIR CEM systems on a side-by-side basis in an extended field test at two coal-fired electric power plants. The FTIR CEM systems monitored the legally mandated criteria pollutants and diluents (CO, CO2, NO, NO2, and SO2) as well as H2O. In addition, one system monitored two HAPs (HCl and HF) and NH3. The FTIR CEM measurements were compared with those from the compliance CEM systems at the facilities. Several relative accuracy test audits were also performed to verify the FTIR CEM accuracy. The second evaluation was recently commenced on behalf of the Environmental Protection Agency. In this study, FTIR CEM systems are evaluated specifically for the monitoring of HAP species by conducting laboratory and field tests. The evaluation culminates in the development of proposed performance specifications and protocols for FTIR CEM systems.
Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W
2015-05-01
Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring and most recently toward insertable device monitoring for several years. Significant advantages and disadvantages pertaining to these monitoring options will be addressed in this review. Insertable cardiac monitors have several advantages over external monitoring techniques and may signify a clinical turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation.
Chandraratna, P Anthony N; Mohar, Dilbahar S; Sidarous, Peter F; Brar, Prabhjyot; Miller, Jeffrey; Shah, Nissar; Kadis, John; Ali, Ashgar; Mohar, Prabhsimran
2012-09-01
This investigation was designed to test the hypothesis that continuous cardiac imaging using an ultrasound transducer developed in our laboratory (ContiScan) is superior to electrocardiogram (ECG) monitoring in the diagnosis of coronary artery disease (CAD) in patients with acute non-ST segment elevation chest pain syndromes. Seventy patients with intermediate to high probability of CAD who presented with typical anginal chest pain and no evidence of ST segment elevation on the ECG were studied. The 2.5-MHz transducer is spherical in its distal part mounted in an external housing to permit steering in 360 degrees. The transducer was placed at the left sternal border to image the left ventricular short-axis view and recorded on video tape at baseline, during and after episodes of chest pain. Two ECG leads were continuously monitored. The presence of CAD was confirmed by coronary arteriography or nuclear or echocardiographic stress testing. Twenty-four patients had regional wall motion abnormalities (RWMA) on their initial echo which were unchanged during the period of monitoring. All had evidence of CAD. Twenty-eight patients had transient RWMA. All had evidence of CAD. Eighteen patients had normal wall motion throughout the monitoring period, 14 of these had no evidence of CAD, and four had evidence of CAD. These four patients did not have chest pain during monitoring. The sensitivity, specificity, and accuracy of echocardiographic monitoring for diagnosing non-ST elevation myocardial infarction was 88%, 100%, and 91% respectively. The sensitivity, specificity, and accuracy of the ECG for diagnosis of CAD were 31%, 100%, and 52%, respectively. Echocardiography was superior to ECG (P < 0.001). The data indicate that continuous cardiac imaging is superior to ECG monitoring for the diagnosis of CAD in patients presenting with acute non-ST segment elevation chest pain syndromes. This technique could be a useful adjunct to ECG monitoring for myocardial ischemia in the acute care setting. © 2012, Wiley Periodicals, Inc.
Gerosa, G; Mazzali, C; Ballarin-Denti, A
2001-10-31
Ozone is the most harmful air pollutant for plant ecosystems in the Mediterranean and Alpine areas due to its biological and economic damage to crops and forests. In order to evaluate the relation between ozone exposure and vegetation injury under on-field conditions, suitable ozone monitoring techniques were investigated. In the framework of a 5-year research project aimed at ozone risk assessment on forests, both continuous analysers and passive samplers were employed during the summer seasons (1994-1998) in different sites of a wide mountain region (80 x 40 km2) on the southern slope of the European Alps. Continuous analysers allowed the recording of ozone hourly concentration means necessary both to calculate specific exposure indexes (such as AOT, SUM, W126) and to record daily time-courses. Passive samplers, even though supplied only weekly mean concentration values, made it possible to estimate the altitude concentration gradient useful to correct the altitude dependence of ozone concentrations to be inserted into exposure indexes. In-canopy ozone profiles were also determined by placing passive samplers at different heights inside the forest canopy. Vertical ozone soundings by means of tethered balloons (kytoons) allowed the measurement of the vertical concentration gradient above the forest canopy. They also revealed ozone reservoirs aloft and were useful to explain the ozone advection dynamic in mountain slopes where ground measurement proved to be inadequate. An intercomparison between passive (PASSAM, CH) and continuous measurements highlighted the necessity to accurately standardize all the exposure operations, particularly the pre- and postexposure conservation at cold temperature to avoid dye (DPE) activity. Advantages and disadvantages from each mentioned technique are discussed.
NASA Astrophysics Data System (ADS)
Stankovic, Miljan R.; Fujii, Alan M.; Kirby, Debra; Boas, David A.; Ntziachristos, Vasilis; Stubblefield, Phillip G.
1997-12-01
The present study demonstrated that optical variables HbT and SmcO2 can be used to monitor changes in cerebral hemodynamics and oxygenation during asphyxia. Unfortunately none of the individual optical variables alone could be used to monitor changes in cerebral hemodynamics and oxygenation under a variety of possible clinical circumstances. However, all variables together, forming patterns unique to the commonly occurring physiological conditions, might potentially serve as a `silver standard' to aid interpretations of optical signals in clinical settings where `gold standard' techniques are not available, i.g. in the human fetus and neonate.
NASA Astrophysics Data System (ADS)
Stankovic, Miljan R.; Fujii, Alan M.; Kirby, Debra; Boas, David A.; Ntziachristos, Vasilis; Stubblefield, Phillip G.
1998-01-01
The present study demonstrated that optical variables HbT and SmcO2 can be used to monitor changes in cerebral hemodynamics and oxygenation during asphyxia. Unfortunately none of the individual optical variables alone could be used to monitor changes in cerebral hemodynamics and oxygenation under a variety of possible clinical circumstances. However, all variables together, forming patterns unique to the commonly occurring physiological conditions, might potentially serve as a `silver standard' to aid interpretations of optical signals in clinical settings where `gold standard' techniques are not available, i.g. in the human fetus and neonate.
Health monitoring of prestressing tendons in post-tensioned concrete structures
NASA Astrophysics Data System (ADS)
Salamone, Salvatore; Bartoli, Ivan; Nucera, Claudio; Phillips, Robert; Lanza di Scalea, Francesco
2011-04-01
Currently 90% of bridges built in California are post-tensioned box-girder. In such structures the steel tendons are the main load-carrying components. The loss of prestress, as well as the presence of defects or the tendon breakage, can be catastrophic for the entire structure. Unfortunately, today there is no well-established method for the monitoring of prestressing (PS) tendons that can provide simultaneous information related to the presence of defects and the level of prestress in a continuous, real time manner. If such a monitoring system were available, considerable savings would be achieved in bridge maintenance since repairs would be implemented in a timely manner without traffic disruptions. This paper presents a health monitoring system for PS tendons in post-tensioned structures of interest to Caltrans. Such a system uses ultrasonic guided waves and embedded sensors to provide simultaneously and in real time, (a) measurements of the level of applied prestress, and (b) defect detection at early grow stages. The proposed PS measurement technique exploits the sensitivity of ultrasonic waves to the inter-wire contact developing in a multi-wire strand as a function of prestress level. In particular the nonlinear ultrasonic behavior of the tendon under changing levels of prestress is monitored by tracking higher-order harmonics at (nω) arising under a fundamental guided-wave excitation at (ω). Moreover this paper also present real-time damage detection and location in post-tensioned bridge joints using Acoustic Emission techniques. Experimental tests on large-scale single-tendon PT joint specimens, subjected to multiple load cycles, will be presented to validate the monitoring of PS loads (through nonlinear ultrasonic probing) and the monitoring of damage progression and location (through acoustic emission techniques). Issues and potential for the use of such techniques to monitor post-tensioned bridges in the field will be discussed.
HALT to qualify electronic packages: a proof of concept
NASA Astrophysics Data System (ADS)
Ramesham, Rajeshuni
2014-03-01
A proof of concept of the Highly Accelerated Life Testing (HALT) technique was explored to assess and optimize electronic packaging designs for long duration deep space missions in a wide temperature range (-150°C to +125°C). HALT is a custom hybrid package suite of testing techniques using environments such as extreme temperatures and dynamic shock step processing from 0g up to 50g of acceleration. HALT testing used in this study implemented repetitive shock on the test vehicle components at various temperatures to precipitate workmanship and/or manufacturing defects to show the weak links of the designs. The purpose is to reduce the product development cycle time for improvements to the packaging design qualification. A test article was built using advanced electronic package designs and surface mount technology processes, which are considered useful for a variety of JPL and NASA projects, i.e. (surface mount packages such as ball grid arrays (BGA), plastic ball grid arrays (PBGA), very thin chip array ball grid array (CVBGA), quad flat-pack (QFP), micro-lead-frame (MLF) packages, several passive components, etc.). These packages were daisy-chained and independently monitored during the HALT test. The HALT technique was then implemented to predict reliability and assess survivability of these advanced packaging techniques for long duration deep space missions in much shorter test durations. Test articles were built using advanced electronic package designs that are considered useful in various NASA projects. All the advanced electronic packages were daisychained independently to monitor the continuity of the individual electronic packages. Continuity of the daisy chain packages was monitored during the HALT testing using a data logging system. We were able to test the boards up to 40g to 50g shock levels at temperatures ranging from +125°C to -150°C. The HALT system can deliver 50g shock levels at room temperature. Several tests were performed by subjecting the test boards to various g levels ranging from 5g to 50g, test durations of 10 minutes to 60 minutes, hot temperatures of up to +125°C and cold temperatures down to -150°C. During the HALT test, electrical continuity measurements of the PBGA package showed an open-circuit, whereas the BGA, MLF, and QFPs showed signs of small variations of electrical continuity measurements. The electrical continuity anomaly of the PBGA occurred in the test board within 12 hours of commencing the accelerated test. Similar test boards were assembled, thermal cycled independently from -150°C to +125°C and monitored for electrical continuity through each package design. The PBGA package on the test board showed an anomalous electrical continuity behavior after 959 thermal cycles. Each thermal cycle took around 2.33 hours, so that a total test time to failure of the PBGA was 2,237 hours (or ~3.1 months) due to thermal cycling alone. The accelerated technique (thermal cycling + shock) required only 12 hours to cause a failure in the PBGA electronic package. Compared to the thermal cycle only test, this was an acceleration of ~186 times (more than 2 orders of magnitude). This acceleration process can save significant time and resources for predicting the life of a package component in a given environment, assuming the failure mechanisms are similar in both the tests. Further studies are in progress to make systematic evaluations of the HALT technique on various other advanced electronic packaging components on the test board. With this information one will be able to estimate the number of mission thermal cycles to failure with a much shorter test program. Further studies are in progress to make systematic study of various components, constant temperature range for both the tests. Therefore, one can estimate the number of hours to fail in a given thermal and shock levels for a given test board physical properties.
Experimental analysis of a mobile health system for mood disorders.
Massey, Tammara; Marfia, Gustavo; Potkonjak, Miodrag; Sarrafzadeh, Majid
2010-03-01
Depression is one of the leading causes of disability. Methods are needed to quantitatively classify emotions in order to better understand and treat mood disorders. This research proposes techniques to improve communication in body sensor network (BSN) that gathers data on the affective states of the patient. These BSNs can continuously monitor, discretely quantify, and classify a patient's depressive states. In addition, data on the patient's lifestyle can be correlated with his/her physiological conditions to identify how various stimuli trigger symptoms. This continuous stream of data is an improvement over a snapshot of localized symptoms that a doctor often collects during a medical examination. Our research first quantifies how the body interferes with communication in a BSN and detects a pattern between the line of sight of an embedded device and its reception rate. Then, a mathematical model of the data using linear programming techniques determines the optimal placement and number of sensors in a BSN to improve communication. Experimental results show that the optimal placement of embedded devices can reduce power cost up to 27% and reduce hardware costs up to 47%. This research brings researchers a step closer to continuous, real-time systemic monitoring that will allow one to analyze the dynamic human physiology and understand, diagnosis, and treat mood disorders.
Complications of thyroid surgery.
Findlay, John M; Mihai, Radu
2011-03-01
The first recorded thyroid operation is credited to Albucacis in Spain in around the year 1000. About 170 years later, Frugardi attempted to induce atrophy of a goitre by transfixing it with shoelaces. From this surgical technique evolved slowly via methods including mass ligatures, chemical cautery, morcellation and injection of turpentine, to the more familiar concepts of modern thyroidectomy (Hegner, 1932; Dionigi et al, 2008). Today, surgeons continue to refine the technique via new equipment such as Harmonic scalpels and nerve monitors, and novel techniques such as minimally-invasive and non-cervical approaches (e.g. via the axilla or the mouth).
Detecting Vital Signs with Wearable Wireless Sensors
Yilmaz, Tuba; Foster, Robert; Hao, Yang
2010-01-01
The emergence of wireless technologies and advancements in on-body sensor design can enable change in the conventional health-care system, replacing it with wearable health-care systems, centred on the individual. Wearable monitoring systems can provide continuous physiological data, as well as better information regarding the general health of individuals. Thus, such vital-sign monitoring systems will reduce health-care costs by disease prevention and enhance the quality of life with disease management. In this paper, recent progress in non-invasive monitoring technologies for chronic disease management is reviewed. In particular, devices and techniques for monitoring blood pressure, blood glucose levels, cardiac activity and respiratory activity are discussed; in addition, on-body propagation issues for multiple sensors are presented. PMID:22163501
USDA-ARS?s Scientific Manuscript database
Termite activity had been continuously monitored in four sections of City Park since 2002. Between 2002 and 2005, 12 distinct Formosan subterranean termite, Coptotermes formosanus Shiraki, colonies had been delineated using mark-release-recapture techniques. This study examines how the distribution ...
Microfabrication techniques for integrated sensors and microsystems.
Wise, K D; Najafi, K
1991-11-29
Integrated sensors and actuators are rapidly evolving to provide an important link between very large scale integrated circuits and nonelectronic monitoring and control applications ranging from biomedicine to automated manufacturing. As they continue to expand, entire microsystems merging electrical, mechanical, thermal, optical, magnetic, and perhaps chemical components should be possible on a common substrate.
USDA-ARS?s Scientific Manuscript database
Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...
Laboratory calibration of impact plates for measuring gravel size and mass
USDA-ARS?s Scientific Manuscript database
Continuous monitoring of gravel transport in rivers is necessary for understanding the impact of dam removal on river systems. Impact plates, such as those deployed on the Elwha River in the state of Washington, USA, are a promising technique; however, relating the data generated by the plates to s...
NASA Astrophysics Data System (ADS)
Chinellato, Giulia; Kenner, Robert; Iasio, Christian; Mair, Volkmar; Mosna, David; Mulas, Marco; Phillips, Marcia; Strada, Claudia; Zischg, Andreas
2014-05-01
In high mountain regions the choice of appropriate sites for infrastructure such as roads, railways, cable cars or hydropower dams is often very limited. In parallel, the increasing demand for supply infrastructure in the Alps induces a continuous transformation of the territory. The new role played by the precautionary monitoring in the risk governance becomes fundamental and may overcome the modeling of future events, which represented so far the predominant approach to these sort of issues. Furthermore the consequence of considering methodologies alternative to those more exclusive allow to reduce costs and increasing the frequency of measurements, updating continuously the cognitive framework of existing hazard condition in most susceptible territories. The scale factor of the observed area and the multiple purpose of such regional ordinary surveys make it convenient to adopt Radar Satellite-based systems, but they need to be integrated with terrestrial systems for validation and eventual early warning purposes. Significant progress over the past decade in Remote Sensing (RS), Proximal Sensing and integration-based sensor networks systems now provide technologies, that allow to implement monitoring systems for ordinary surveys of extensive areas or regions, which are affected by active natural processes and slope instability. The Interreg project SloMove aims to provide solutions for such challenges and focuses on using remote sensing monitoring techniques for the monitoring of mass movements in two test sites, in South Tyrol (Italy) and in Grisons Canton (Switzerland). The topics faced in this project concern mass movements and slope deformation monitoring techniques, focusing mainly on the integration of multi-temporal interferometry, new generation of terrestrial technologies for differential digital terrain model elaboration provided by laser scanner (TLS), and GNSS-based topographic surveys, which are used not only for validation purpose, but also for adding value and information to the whole monitoring survey. The test sites are currently observed by an original integrated methodology specifically developed within the aim of the project. The integrated monitoring design includes reference targets for the different monitoring systems placed together on the same point or rigid foundation, to facilitate the comparison of the data and, in the operational use, to be able to switch consistently from one to the other system. The principal goal of the project is to define a shared procedure to select scalable technologies, best practices and institutional action plans more adequate to deal with different sort of hazard related to ground displacement, in densely populated mountain areas containing recreational and critical infrastructures. Keywords: integrated monitoring, multi-temporal interferometry, artificial reflectors; mass movement, SloMove.eu
Corrosion monitoring on a large steel pressure vessel by thin-layer activation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, G.; Boulton, L.H.; Hodder, D.
1989-12-01
Thin-layer activation (TLA) is a technique in which a surface is irradiated by a nuclear accelerator and thereby labeled with an accurate depth profile of low-level radioactivity. By monitoring this activity it is possible to calculate how much of that surface has been removed by corrosion. As the radioactivity is marked by the emission of penetrating gamma rays, it is possible to monitor this corrosion remotely through several centimeters of steel. This technique has been used to monitor erosion-corrosion occurring on the inner carbon steel wall of a continuous Kraft pulp digester at a paper mill. Representative coupons of themore » same steel as the digester wall were irradiated and fixed to the walls in the liquor extraction zone during a maintenance shutdown. The loss of metal over the six months was measured by external monitoring of gamma radiation through the vessel wall, and converted to a corrosion rate. Subsequent weight-loss measurements and comparison with ultrasonic thickness measurements established that the corrosion rate measured gave accurate results over a much shorter time scale. TLA thus enables current, rather than historical corrosion rates to be measured in a large steel pressure vessel.« less
Field test of an alternative longwall gate road design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, R.M.; Vandergrift, T.L.; McDonnell, J.P.
1994-01-01
The US Bureau of Mines (USBM) MULSIM/ML modeling technique has been used to analyze anticipated stress distributions for a proposed alternative longwall gate road design for a western Colorado coal mine. The model analyses indicated that the alternative gate road design would reduce stresses in the headgate entry. To test the validity of the alternative gate road design under actual mining conditions, a test section of the alternative system was incorporated into a subsequent set of gate roads developed at the mine. The alternative gate road test section was instrumented with borehole pressure cells, as part of an ongoing USBMmore » research project to monitor ground pressure changes as longwall mining progressed. During the excavation of the adjacent longwall panels, the behavior of the alternative gate road system was monitored continuously using the USBM computer-assisted Ground Control Management System. During these field tests, the alternative gate road system was first monitored and evaluated as a headgate, and later monitored and evaluated as a tailgate. The results of the field tests confirmed the validity of using the MULSIM/NL modeling technique to evaluate mine designs.« less
Development of Rayleigh Doppler lidar for measuring middle atmosphere winds
NASA Astrophysics Data System (ADS)
Raghunath, K.; Patra, A. K.; Narayana Rao, D.
Interpretation of most of the middle and upper atmospheric dynamical and chemical data relies on the climatological description of the wind field Rayleigh Doppler lidar is one instrument which monitors wind profiles continuously though continuity is limited to clear meteorological conditions in the middle atmosphere A Doppler wind lidar operating in incoherent mode gives excellent wind and temperature information at these altitudes with necessary spectral sensitivity It observes atmospheric winds by measuring the spectral shift of the scattered light due to the motions of atmospheric molecules with background winds and temperature by spectral broadening The presentation is about the design and development of Incoherent Doppler lidar to obtain wind information in the height regions of 30-65 km The paper analyses and describes various types of techniques that can be adopted viz Edge technique and Fringe Imaging technique The paper brings out the scientific objectives configuration simulations error sources and technical challenges involved in the development of Rayleigh Doppler lidar The presentation also gives a novel technique for calibrating the lidar
Fang, Wei; Ni, Zhaohui; Qian, Jiaqi
2014-01-01
The proportion of end-stage renal disease (ESRD) patients on peritoneal dialysis (PD) has increased very fast in China over the last decade. Renji Hospital, affiliated with Shanghai Jiaotong University School of Medicine, is a recognized high-quality PD unit with a high PD utilization rate, excellent patient and technique survival (1-year and 5-year patient survival rate of 93% and 71%, and 1-year and 5-year technique survival of 96% and 82%, respectively), low peritonitis rate and a well-documented good quality of life of the treated patients. We believe that a dedicated and experienced PD team, a structured patient training program, continuous patient support, establishing and utilizing standardized protocols, starting PD with low dialysis dose, monitoring key performance indicators (KPIs), and continuous quality improvement (CQI) are the key factors underlying this successful PD program. PMID:24962961
Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.
Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther
2017-07-01
Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.
The history of the coronary care unit.
Khush, Kiran K; Rapaport, Elliot; Waters, David
2005-10-01
The first coronary care units were established in the early 1960s in an attempt to reduce mortality from acute myocardial infarction. Pioneering cardiologists recognized the threat of death due to malignant arrhythmias in the postinfarction setting, and developed techniques for successful external defibrillation. The ability to abort sudden death led to continuous monitoring of the cardiac rhythm and an organized system of cardiopulmonary resuscitation, incorporating external defibrillation with cardiac drugs and specialized equipment. Arrhythmia monitoring and cardiopulmonary resuscitation could be performed by trained nursing staff, which eliminated delays in treatment and significantly reduced mortality. These early triumphs in aborting sudden death led to the development of techniques to treat cardiogenic shock, limit infarct size and initiate prehospital coronary care, all of which laid the foundation for the current era of interventional cardiology.
Multimodal intraoperative monitoring: an overview and proposal of methodology based on 1,017 cases
Eggspuehler, Andreas; Muller, Alfred; Dvorak, Jiri
2007-01-01
To describe different currently available tests of multimodal intraoperative monitoring (MIOM) used in spine and spinal cord surgery indicating the technical parameters, application and interpretation as an easy understanding systematic overview to help implementation of MIOM and improve communication between neurophysiologists and spine surgeons. This article aims to give an overview and proposal of the different MIOM-techniques as used daily in spine and spinal cord surgery at our institution. Intensive research in neurophysiology over the past decades has lead to a profound understanding of the spinal cord, nerve functions and their intraoperative functional evaluation in anaesthetised patients. At present, spine surgeons and neurophysiologist are faced with 1,883 publications in PubMed on spinal cord monitoring. The value and the limitations of single monitoring methods are well documented. The diagnostic power of the multimodal approach in a larger study population in spine surgery, as measured with sensitivity and specificity, is dealt with elsewhere in this supplement (Sutter et al. in Eur Spine J Suppl, 2007). This paper aims to give a detailed description of the different modalities used in this study. Description of monitoring techniques of the descending and ascending spinal cord and nerve root pathways by motor evoked potentials of the spinal cord and muscles elicited after transcranial electrical motor cortex, spinal cord, cauda equina and nerve root stimulation, continuous EMG, sensory cortical and spinal evoked potentials, as well as direct spinal cord evoked potentials applied on 1,017 patients. The method of MIOM, continuously adapted according to the site, stage of surgery and potential danger to nerve tissues, proved to be applicable with online results, reliable and furthermore teachable. PMID:17653777
Blast optimization for improved dragline productivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humphreys, M.; Baldwin, G.
1994-12-31
A project aimed at blast optimization for large open pit coal mines is utilizing blast monitoring and analysis techniques, advanced dragline monitoring equipment, and blast simulation software, to assess the major controlling factors affecting both blast performance and subsequent dragline productivity. This has involved collaborative work between the explosives supplier, mine operator, monitoring equipment manufacturer, and a mining research organization. The results from trial blasts and subsequently monitored dragline production have yielded promising results and continuing studies are being conducted as part of a blast optimization program. It should be stressed that the optimization of blasting practices for improved draglinemore » productivity is a site specific task, achieved through controlled and closely monitored procedures. The benefits achieved at one location can not be simply transferred to another minesite unless similar improvement strategies are first implemented.« less
Facial nerve mapping and monitoring in lymphatic malformation surgery.
Chiara, Jospeh; Kinney, Greg; Slimp, Jefferson; Lee, Gi Soo; Oliaei, Sepehr; Perkins, Jonathan A
2009-10-01
Establish the efficacy of preoperative facial nerve mapping and continuous intraoperative EMG monitoring in protecting the facial nerve during resection of cervicofacial lymphatic malformations. Retrospective study in which patients were clinically followed for at least 6 months postoperatively, and long-term outcome was evaluated. Patient demographics, lesion characteristics (i.e., size, stage, location) were recorded. Operative notes revealed surgical techniques, findings, and complications. Preoperative, short-/long-term postoperative facial nerve function was standardized using the House-Brackmann Classification. Mapping was done prior to incision by percutaneously stimulating the facial nerve and its branches and recording the motor responses. Intraoperative monitoring and mapping were accomplished using a four-channel, free-running EMG. Neurophysiologists continuously monitored EMG responses and blindly analyzed intraoperative findings and final EMG interpretations for abnormalities. Seven patients collectively underwent 8 lymphatic malformation surgeries. Median age was 30 months (2-105 months). Lymphatic malformation diagnosis was recorded in 6/8 surgeries. Facial nerve function was House-Brackmann grade I in 8/8 cases preoperatively. Facial nerve was abnormally elongated in 1/8 cases. EMG monitoring recorded abnormal activity in 4/8 cases--two suggesting facial nerve irritation, and two with possible facial nerve damage. Transient or long-term facial nerve paresis occurred in 1/8 cases (House-Brackmann grade II). Preoperative facial nerve mapping combined with continuous intraoperative EMG and mapping is a successful method of identifying the facial nerve course and protecting it from injury during resection of cervicofacial lymphatic malformations involving the facial nerve.
Instrumentation techniques for monitoring shock and detonation waves
NASA Astrophysics Data System (ADS)
Dick, R. D.; Parrish, R. L.
1985-09-01
CORRTEX (Continuous Reflectometry for Radius Versus Time Experiments), SLIFER (Shorted Location Indication by Frequency of Electrical Resonance), and pin probes were used to monitor several conditions of blasting such as the detonation velocity of the explosive, the functioning of the stemming column confining the explosive, and rock mass motion. CORRTEX is a passive device that employs time-domain reflectometry to interrogate the two-way transit time of a coaxial cable. SLIFER is an active device that monitors the changing frequency resulting from a change in length of a coaxial cable forming an element of an oscillator circuit. Pin probes in this application consist of RG-174 coaxial cables, each with an open circuit, placed at several known locations within the material. Each cable is connected to a pulse-forming network and a voltage source. When the cables are shorted by the advancing wave, time-distance data are produced from which a velocity can be computed. Each technique, installation of the gauge, examples of the signals, and interpretation of the records are described.
Sustainability and in situ monitoring in battery development
NASA Astrophysics Data System (ADS)
Grey, C. P.; Tarascon, J. M.
2017-01-01
The development of improved rechargeable batteries represents a major technological challenge for this new century, as batteries constitute the limiting components in the shift from petrol (gasoline) powered to electric vehicles, while also enabling the use of more renewable energy on the grid. To minimize the ecological implications associated with their wider use, we must integrate sustainability of battery materials into our research endeavours, choosing chemistries that have a minimum footprint in nature and that are more readily recycled or integrated into a full circular economy. Sustainability and cost concerns require that we greatly increase the battery lifetime and consider second lives for batteries. As part of this, we must monitor the state of health of batteries continuously during operation to minimize their degradation. It is thus important to push the frontiers of operando techniques to monitor increasingly complex processes. In this Review, we will describe key advances in both more sustainable chemistries and operando techniques, along with some of the remaining challenges and possible solutions, as we personally perceive them.
Automatic aeroponic irrigation system based on Arduino’s platform
NASA Astrophysics Data System (ADS)
Montoya, A. P.; Obando, F. A.; Morales, J. G.; Vargas, G.
2017-06-01
The recirculating hydroponic culture techniques, as aeroponics, has several advantages over traditional agriculture, aimed to improve the efficiently and environmental impact of agriculture. These techniques require continuous monitoring and automation for proper operation. In this work was developed an automatic monitored aeroponic-irrigation system based on the Arduino’s free software platform. Analog and digital sensors for measuring the temperature, flow and level of a nutrient solution in a real greenhouse were implemented. In addition, the pH and electric conductivity of nutritive solutions are monitored using the Arduino’s differential configuration. The sensor network, the acquisition and automation system are managed by two Arduinos modules in master-slave configuration, which communicate one each other wireless by Wi-Fi. Further, data are stored in micro SD memories and the information is loaded on a web page in real time. The developed device brings important agronomic information when is tested with an arugula culture (Eruca sativa Mill). The system also could be employ as an early warning system to prevent irrigation malfunctions.
Sustainability and in situ monitoring in battery development.
Grey, C P; Tarascon, J M
2016-12-20
The development of improved rechargeable batteries represents a major technological challenge for this new century, as batteries constitute the limiting components in the shift from petrol (gasoline) powered to electric vehicles, while also enabling the use of more renewable energy on the grid. To minimize the ecological implications associated with their wider use, we must integrate sustainability of battery materials into our research endeavours, choosing chemistries that have a minimum footprint in nature and that are more readily recycled or integrated into a full circular economy. Sustainability and cost concerns require that we greatly increase the battery lifetime and consider second lives for batteries. As part of this, we must monitor the state of health of batteries continuously during operation to minimize their degradation. It is thus important to push the frontiers of operando techniques to monitor increasingly complex processes. In this Review, we will describe key advances in both more sustainable chemistries and operando techniques, along with some of the remaining challenges and possible solutions, as we personally perceive them.
Modern developments for ground-based monitoring of fire behavior and effects
Colin C. Hardy; Robert Kremens; Matthew B. Dickinson
2010-01-01
Advances in electronic technology over the last several decades have been staggering. The cost of electronics continues to decrease while system performance increases seemingly without limit. We have applied modern techniques in sensors, electronics and instrumentation to create a suite of ground based diagnostics that can be used in laboratory (~ 1 m2), field scale...
NASA Astrophysics Data System (ADS)
Han, Xiuzhen; Ma, Jianwen; Bao, Yuhai
2006-12-01
Currently the function of operational locust monitor system mainly focused on after-hazards monitoring and assessment, and to found the way effectively to perform early warning and prediction has more practical meaning. Through 2001, 2002 two years continuously field sample and statistics for locusts eggs hatching, nymph growth, adults 3 phases observation, sample statistics and calculation, spectral measurements as well as synchronically remote sensing data processing we raise the view point of Remote Sensing three stage monitor the locust hazards. Based on the point of view we designed remote sensing monitor in three stages: (1) during the egg hitching phase remote sensing can retrieve parameters of land surface temperature (LST) and soil moisture; (2) during nymph growth phase locust increases appetite greatly and remote sensing can calculate vegetation index, leaf area index, vegetation cover and analysis changes; (3) during adult phase the locust move and assembly towards ponds and water ditches as well as less than 75% vegetation cover areas and remote sensing combination with field data can monitor and predicts potential areas for adult locusts to assembly. In this way the priority of remote sensing technology is elaborated effectively and it also provides technique support for the locust monitor system. The idea and techniques used in the study can also be used as reference for other plant diseases and insect pests.
Update to permeable pavement research at the Edison ...
Abstract: The EPA’s Urban Watershed Management Branch (UWMB) has been monitoring the permeable pavement demonstration site at the Edison Environmental Center, NJ since 2010. This site has three different types of permeable pavement including: interlocking concrete permeable pavers; porous concrete; and permeable asphalt. The parking lot is instrumented with water content reflectometers and thermistors for continuous monitoring and has four lined sections for each surface to capture permeable pavement infiltrate for water quality analyses.Previous technical releases concerning the demonstration site focused on monitoring techniques, observed chloride and nutrient concentrations, and infiltration and evaporation rates. Thispresentation summarizes past findings and addresses current water quality efforts. This presentation summarizes past findings and addresses current water quality efforts.
Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L.
2016-05-15
Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmablemore » translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three-dimensional position estimation from monoscopic imaging permits continuous, uninterrupted intrafraction motion monitoring even in the presence of gantry rotation, which may block kV sources or imagers. This potentially allows for more accurate treatment delivery, by ensuring that the prostate does not deviate substantially from the initial setup position.« less
NASA Astrophysics Data System (ADS)
Colla, C.; Gabrielli, E.
2017-01-01
To evaluate the complex behaviour of masonry structures under mechanical loads, numerical models are developed and continuously implemented at diverse scales, whilst, from an experimental viewpoint, laboratory standard mechanical tests are usually carried out by instrumenting the specimens via traditional measuring devices. Extracted values collected in the few points where the tools were installed are assumed to represent the behaviour of the whole specimen but this may be quite optimistic or approximate. Optical monitoring techniques may help in overcoming some of these limitations by providing full-field visualization of mechanical parameters. Photoelasticity and the more recent DIC, employed to monitor masonry columns during compression tests are here presented and a lab case study is compared listing procedures, data acquisitions, advantages and limitations. It is shown that the information recorded by traditional measuring tools must be considered limited to the specific instrumented points. Instead, DIC in particular among the optical techniques, is proving both a very precise global and local picture of the masonry performance, opening new horizons towards a deeper knowledge of this complex construction material. The applicability of an innovative DIC procedure to cultural heritage constructions is also discussed.
Monitoring a Complex Physical System using a Hybrid Dynamic Bayes Net
NASA Technical Reports Server (NTRS)
Lerner, Uri; Moses, Brooks; Scott, Maricia; McIlraith, Sheila; Keller, Daphne
2005-01-01
The Reverse Water Gas Shift system (RWGS) is a complex physical system designed to produce oxygen from the carbon dioxide atmosphere on Mars. If sent to Mars, it would operate without human supervision, thus requiring a reliable automated system for monitoring and control. The RWGS presents many challenges typical of real-world systems, including: noisy and biased sensors, nonlinear behavior, effects that are manifested over different time granularities, and unobservability of many important quantities. In this paper we model the RWGS using a hybrid (discrete/continuous) Dynamic Bayesian Network (DBN), where the state at each time slice contains 33 discrete and 184 continuous variables. We show how the system state can be tracked using probabilistic inference over the model. We discuss how to deal with the various challenges presented by the RWGS, providing a suite of techniques that are likely to be useful in a wide range of applications. In particular, we describe a general framework for dealing with nonlinear behavior using numerical integration techniques, extending the successful Unscented Filter. We also show how to use a fixed-point computation to deal with effects that develop at different time scales, specifically rapid changes occuring during slowly changing processes. We test our model using real data collected from the RWGS, demonstrating the feasibility of hybrid DBNs for monitoring complex real-world physical systems.
NASA Astrophysics Data System (ADS)
Reagan, Daniel; Sabato, Alessandro; Niezrecki, Christopher
2017-04-01
Civil engineering structures such as bridges, buildings, and tunnels continue to be used despite aging and deterioration well past their design life. In 2013, the American Society of Civil Engineers (ASCE) rated the state of the U.S. bridges as mediocre, despite the $12.8 billion USD annually invested. Traditional inspection and monitoring techniques may produce inconsistent results, are labor intensive and too time-consuming to be considered effective for large-scale monitoring. Therefore, new structural health monitoring systems must be developed that are automated, highly accurate, minimally invasive, and cost effective. Three-dimensional (3D) digital image correlation (DIC) systems possess the capability of extracting full-field strain, displacement, and geometry profiles. Furthermore, as this measurement technique is implemented within an Unmanned Aerial Vehicle (UAV) the capability to expedite the optical-based measurement process is increased as well as the infrastructure downtime being reduced. These resulting integrity maps of the structure of interest can be easily interpreted by trained personal. Within this paper, the feasibility of performing DIC measurements using a pair of cameras installed on a UAV is shown. Performance is validated with in-flight measurements. Also, full-field displacement monitoring, 3D measurement stitching, and 3D point-tracking techniques are employed in conjunction with 3D mapping and data management software. The results of these experiments show that the combination of autonomous flight with 3D DIC and other non-contact measurement systems provides a highly valuable and effective civil inspection platform.
Wearable PWV technologies to measure Blood Pressure: eliminating brachial cuffs.
Solá, J; Proença, M; Chételat, O
2013-01-01
The clinical demand for technologies to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is strong: new generation of BP monitors are expected to be not only accurate, but also non-occlusive. In this paper we review recent advances on the use of the so-called Pulse Wave Velocity (PWV) technologies to estimate BP in a beat-by-beat basis. After introducing the working principle and underlying methodological limitations, two implementation examples are provided. Pilot studies have demonstrated that novel PWV-based BP monitors depict accuracy scores falling within the limits of the British Hypertensive Society (BHS) Grade A standard. The reported techniques pave the way towards ambulatory-compliant, continuous and non-occlusive BP monitoring devices, where the use of inflation cuffs is drastically reduced.
Koop, A; Cobbold, P H
1993-01-01
We have devised a technique for monitoring cytoplasmic ATP continuously in single hepatocytes. Single isolated rat hepatocytes were injected with the ATP-dependent luminescent protein firefly luciferase, and then superfused with 45 microM luciferin in air-equilibrated medium. Signals of approx. 10-200 photoelectron counts per second could be recorded from individual healthy cells for up to 3 h. The response of the luminescent signal to chemical hypoxia (2-5 mM CN- and 5-10 mM 2-deoxyglucose) was monitored. We found a great cell-to-cell variability in the time course of the ATP decline in response to CN-, 2-deoxyglucose or to their combination; the time for the signal to fall to 10% of the original (corresponding to approx. 100 microM ATP) ranged from approx. 20 to 75 min. This resistance of the cytoplasmic ATP concentration to depletion after blockade of oxidative phosphorylation and glycolysis could be abolished by pretreatment of the cells with etomoxir, which blocks mitochondrial beta-oxidation. Etomoxir alone had no effect on the luciferase signal, but etomoxir-pre-treated cells showed a prompt fall in the luciferase signal starting within 1-2 min of application of cyanide and 2-deoxyglucose and falling to 10% of the original signal in approx. 6-10 min. The technique allows cytoplasmic ATP changes to be monitored in single hepatocytes at concentrations of 1 mM or lower, but more precise calibration of the signal will require correction for the effects of cytoplasmic pH changes. PMID:8216212
Report of the panel on international programs
NASA Technical Reports Server (NTRS)
Anderson, Allen Joel; Fuchs, Karl W.; Ganeka, Yasuhiro; Gaur, Vinod; Green, Andrew A.; Siegfried, W.; Lambert, Anthony; Rais, Jacub; Reighber, Christopher; Seeger, Herman
1991-01-01
The panel recommends that NASA participate and take an active role in the continuous monitoring of existing regional networks, the realization of high resolution geopotential and topographic missions, the establishment of interconnection of the reference frames as defined by different space techniques, the development and implementation of automation for all ground-to-space observing systems, calibration and validation experiments for measuring techniques and data, the establishment of international space-based networks for real-time transmission of high density space data in standardized formats, tracking and support for non-NASA missions, and the extension of state-of-the art observing and analysis techniques to developing nations.
Single station monitoring of volcanoes using seismic ambient noise
NASA Astrophysics Data System (ADS)
De Plaen, R. S.; Lecocq, T.; Caudron, C.; Ferrazzini, V.; Francis, O.
2016-12-01
During volcanic eruptions, magma transport causes gas release, pressure perturbations and fracturing in the plumbing system. The potential subsequent surface deformation that can be detected using geodetic techniques and deep mechanical processes associated with magma pressurization and/or migration and their spatial-temporal evolution can be monitored with volcanic seismicity. However, these techniques respectively suffer from limited sensitivity to deep changes and a too short-term temporal distribution to expose early aseismic processes such as magma pressurisation. Seismic ambient noise cross-correlation uses the multiple scattering of seismic vibrations by heterogeneities in the crust to retrieves the Green's function for surface waves between two stations by cross-correlating these diffuse wavefields. Seismic velocity changes are then typically measured from the cross-correlation functions with applications for volcanoes, large magnitude earthquakes in the far field and smaller magnitude earthquakes at smaller distances. This technique is increasingly used as a non-destructive way to continuously monitor small seismic velocity changes ( 0.1%) associated with volcanic activity, although it is usually limited to volcanoes equipped with large and dense networks of broadband stations. The single-station approach may provide a powerful and reliable alternative to the classical "cross-stations" approach when measuring variation of seismic velocities. We implemented it on the Piton de la Fournaise in Reunion Island, a very active volcano with a remarkable multi-disciplinary continuous monitoring. Over the past decade, this volcano was increasingly studied using the traditional cross-station approach and therefore represents a unique laboratory to validate our approach. Our results, tested on stations located up to 3.5 km from the eruptive site, performed as well as the classical approach to detect the volcanic eruption in the 1-2 Hz frequency band. This opens new perspectives to successfully forecast volcanic activity at volcanoes equipped with a single 3-component seismometer.
A real-time monitoring system for the facial nerve.
Prell, Julian; Rachinger, Jens; Scheller, Christian; Alfieri, Alex; Strauss, Christian; Rampp, Stefan
2010-06-01
Damage to the facial nerve during surgery in the cerebellopontine angle is indicated by A-trains, a specific electromyogram pattern. These A-trains can be quantified by the parameter "traintime," which is reliably correlated with postoperative functional outcome. The system presented was designed to monitor traintime in real-time. A dedicated hardware and software platform for automated continuous analysis of the intraoperative facial nerve electromyogram was specifically designed. The automatic detection of A-trains is performed by a software algorithm for real-time analysis of nonstationary biosignals. The system was evaluated in a series of 30 patients operated on for vestibular schwannoma. A-trains can be detected and measured automatically by the described method for real-time analysis. Traintime is monitored continuously via a graphic display and is shown as an absolute numeric value during the operation. It is an expression of overall, cumulated length of A-trains in a given channel; a high correlation between traintime as measured by real-time analysis and functional outcome immediately after the operation (Spearman correlation coefficient [rho] = 0.664, P < .001) and in long-term outcome (rho = 0.631, P < .001) was observed. Automated real-time analysis of the intraoperative facial nerve electromyogram is the first technique capable of reliable continuous real-time monitoring. It can critically contribute to the estimation of functional outcome during the course of the operative procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Farnebo, S; Winbladh, A; Zettersten, E K; Sandström, P; Gullstrand, P; Samuelsson, A; Theodorson, E; Sjöberg, F
2010-01-01
Delayed detection of ischemia is one of the most feared postoperative complications. Early detection of impaired blood flow and close monitoring of the organ-specific metabolic status may therefore be critical for the surgical outcome. Urea clearance is a new technique for continuous monitoring of alterations in blood flow and metabolic markers with acceptable temporal characteristics. We compare this new microdialysis technique with the established microdialysis ethanol technique to assess hepatic blood flow. Six pigs were used in a liver ischemia/reperfusion injury model. Microdialysis catheters were placed in liver segment IV and all circulation was stopped for 80 min, followed by reperfusion for 220 min. Urea and ethanol clearance was calculated from the dialysate and correlated with metabolic changes. A laser Doppler probe was used as reference of restoration of blood flow. Both urea and ethanol clearance reproducibly depicted changes in liver blood flow in relation to metabolic changes and laser Doppler measurements. The two techniques highly correlated both overall and during the reperfusion phase (r = 0.8) and the changes were paralleled by altered perfusion as recorded by laser Doppler. Copyright © 2010 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Lishnevskii, A. E.; Benghin, V. V.
2018-03-01
The DB-8 detectors of the ISS radiation monitoring system (RMS) have operated almost continuously onboard the ISS service module since August 2001 till December 2014. The RMS data obtained were used for the daily monitoring of the radiation environment aboard the station. This paper considers the technique of RMS data analysis that allows one to distinguish the contributions of galactic cosmic rays and the Earth's inner radiation belt to the daily dose based on the dosimetry data obtained as a result of the station's passage in areas of the highest geomagnetic latitudes. The paper presents the results of an analysis of the dosimetry data based on this technique for 2005-2011, as well as a comparison with similar results the authors obtained previously using the technique based on an analysis of the dosimetry data obtained during station passages in the area of the South Atlantic Anomaly.
Current techniques in acid-chloride corrosion control and monitoring at The Geysers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirtz, Paul; Buck, Cliff; Kunzman, Russell
1991-01-01
Acid chloride corrosion of geothermal well casings, production piping and power plant equipment has resulted in costly corrosion damage, frequent curtailments of power plants and the permanent shut-in of wells in certain areas of The Geysers. Techniques have been developed to mitigate these corrosion problems, allowing continued production of steam from high chloride wells with minimal impact on production and power generation facilities.The optimization of water and caustic steam scrubbing, steam/liquid separation and process fluid chemistry has led to effective and reliable corrosion mitigation systems currently in routine use at The Geysers. When properly operated, these systems can yield steammore » purities equal to or greater than those encountered in areas of The Geysers where chloride corrosion is not a problem. Developments in corrosion monitoring techniques, steam sampling and analytical methodologies for trace impurities, and computer modeling of the fluid chemistry has been instrumental in the success of this technology.« less
Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman
2015-01-01
Recent advances in the field of centrifugal microfluidic disc suggest the need for electrical interface in the disc to perform active biomedical assays. In this paper, we have demonstrated an active application powered by the energy harvested from the rotation of the centrifugal microfluidic disc. A novel integration of power harvester disc onto centrifugal microfluidic disc to perform localized heating technique is the main idea of our paper. The power harvester disc utilizing electromagnetic induction mechanism generates electrical energy from the rotation of the disc. This contributes to the heat generation by the embedded heater on the localized heating disc. The main characteristic observed in our experiment is the heating pattern in relative to the rotation of the disc. The heating pattern is monitored wirelessly with a digital temperature sensing system also embedded on the disc. Maximum temperature achieved is 82 °C at rotational speed of 2000 RPM. The technique proves to be effective for continuous heating without the need to stop the centrifugal motion of the disc.
Applied Remote Sensing Program (ARSP)
NASA Technical Reports Server (NTRS)
Johnson, J. D.; Foster, K. E.; Mouat, D. A.; Miller, D. A.; Conn, J. S.
1976-01-01
The activities and accomplishments of the Applied Remote Sensing Program during FY 1975-1976 are reported. The principal objective of the Applied Remote Sensing Program continues to be designed projects having specific decision-making impacts as a principal goal. These projects are carried out in cooperation and collaboration with local, state and federal agencies whose responsibilities lie with planning, zoning and environmental monitoring and/or assessment in the application of remote sensing techniques. The end result of the projects is the use by the involved agencies of remote sensing techniques in problem solving.
Brouckaert, Davinia; De Meyer, Laurens; Vanbillemont, Brecht; Van Bockstal, Pieter-Jan; Lammens, Joris; Mortier, Séverine; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas
2018-04-03
Near-infrared chemical imaging (NIR-CI) is an emerging tool for process monitoring because it combines the chemical selectivity of vibrational spectroscopy with spatial information. Whereas traditional near-infrared spectroscopy is an attractive technique for water content determination and solid-state investigation of lyophilized products, chemical imaging opens up possibilities for assessing the homogeneity of these critical quality attributes (CQAs) throughout the entire product. In this contribution, we aim to evaluate NIR-CI as a process analytical technology (PAT) tool for at-line inspection of continuously freeze-dried pharmaceutical unit doses based on spin freezing. The chemical images of freeze-dried mannitol samples were resolved via multivariate curve resolution, allowing us to visualize the distribution of mannitol solid forms throughout the entire cake. Second, a mannitol-sucrose formulation was lyophilized with variable drying times for inducing changes in water content. Analyzing the corresponding chemical images via principal component analysis, vial-to-vial variations as well as within-vial inhomogeneity in water content could be detected. Furthermore, a partial least-squares regression model was constructed for quantifying the water content in each pixel of the chemical images. It was hence concluded that NIR-CI is inherently a most promising PAT tool for continuously monitoring freeze-dried samples. Although some practicalities are still to be solved, this analytical technique could be applied in-line for CQA evaluation and for detecting the drying end point.
Monte Carlo simulation of non-invasive glucose measurement based on FMCW LIDAR
NASA Astrophysics Data System (ADS)
Xiong, Bing; Wei, Wenxiong; Liu, Nan; He, Jian-Jun
2010-11-01
Continuous non-invasive glucose monitoring is a powerful tool for the treatment and management of diabetes. A glucose measurement method, with the potential advantage of miniaturizability with no moving parts, based on the frequency modulated continuous wave (FMCW) LIDAR technology is proposed and investigated. The system mainly consists of an integrated near-infrared tunable semiconductor laser and a detector, using heterodyne technology to convert the signal from time-domain to frequency-domain. To investigate the feasibility of the method, Monte Carlo simulations have been performed on tissue phantoms with optical parameters similar to those of human interstitial fluid. The simulation showed that the sensitivity of the FMCW LIDAR system to glucose concentration can reach 0.2mM. Our analysis suggests that the FMCW LIDAR technique has good potential for noninvasive blood glucose monitoring.
Integrated monitoring technologies for the management of a Soil-Aquifer-Treatment (SAT) system.
NASA Astrophysics Data System (ADS)
Papadopoulos, Alexandros; Kallioras, Andreas; Kofakis, Petros; Bumberger, Jan; Schmidt, Felix; Athanasiou, Georgios; Uzunoglou, Nikolaos; Amditis, Angelos; Dietrich, Peter
2016-04-01
Artificial recharge of groundwater has an important role to play in water reuse as treated wastewater effluent can be infiltrated into the ground for aquifer recharge. As the effluent moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. The pilot site of Lavrion Technological & Cultural Park (LTCP) of the National Technical University of Athens (NTUA), involves the employment of plot infiltration basins at experimental scale, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. Τhe LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved by the development and installation of an integrated system of prototype sensing technologies, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time and Frequency Domain Reflectometry (TDR & FDR) sensors is developed and will be installed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. Additionally, the system contains two different radar-based sensing systems that will be offering (i) identification of preferential flow effects of the TDR/FDR sensors and (ii) monitoring of the water table within the shallow karst aquifer layer. The above technique will offer continuous monitoring of infiltration rates and identify possible mechanical or biological clogging effects. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.
Experiences and recommendations in deploying a real-time, water quality monitoring system
NASA Astrophysics Data System (ADS)
O'Flynn, B.; Regan, F.; Lawlor, A.; Wallace, J.; Torres, J.; O'Mathuna, C.
2010-12-01
Monitoring of water quality at a river basin level to meet the requirements of the Water Framework Directive (WFD) using conventional sampling and laboratory-based techniques poses a significant financial burden. Wireless sensing systems offer the potential to reduce these costs considerably, as well as provide more useful, continuous monitoring capabilities by giving an accurate idea of the changing environmental and water quality in real time. It is unlikely that the traditional spot/grab sampling will provide a reasonable estimate of the true maximum and/or mean concentration for a particular physicochemical variable in a water body with marked temporal variability. When persistent fluctuations occur, it is likely only to be detected through continuous measurements, which have the capability of detecting sporadic peaks of concentration. Thus, in situ sensors capable of continuous sampling of parameters required under the WFD would therefore provide more up-to-date information, cut monitoring costs and provide better coverage representing long-term trends in fluctuations of pollutant concentrations. DEPLOY is a technology demonstration project, which began planning and station selection and design in August 2008 aiming to show how state-of-the-art technology could be implemented for cost-effective, continuous and real-time monitoring of a river catchment. The DEPLOY project is seen as an important building block in the realization of a wide area autonomous network of sensors capable of monitoring the spatial and temporal distribution of important water quality and environmental target parameters. The demonstration sites chosen are based in the River Lee, which flows through Ireland's second largest city, Cork, and were designed to include monitoring stations in five zones considered typical of significant river systems--these monitor water quality parameters such as pH, temperature, depth, conductivity, turbidity and dissolved oxygen. Over one million data points have been collected since the multi-sensor system was deployed in May 2009. Extreme meteorological events have occurred during the period of deployment and the collection of real-time water quality data as well as the knowledge, experience and recommendations for future deployments are discussed.
Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny
2014-03-01
Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30 cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72 h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25 cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49 ml min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63 ml min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17 ml min⁻¹ with continuous cuff pressure monitoring (P <0.001). Using a SACETT tracheal tube with a subglottic aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48 ml min⁻¹ (P <0.001). Subglottic secretions leaked past the tracheal tube cuff with all tube types and cuff pressure monitoring strategies in this model. Significantly higher rates were observed with continuous cuff pressure monitoring and significantly lower rates were observed when using a tracheal tube with a subglottic aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.
Monitoring displacements of an earthen dam using GNSS and remote sensing
NASA Astrophysics Data System (ADS)
Dardanelli, Gino; La Loggia, Goffredo; Perfetti, Nicola; Capodici, Fulvio; Puccio, Luigi; Maltese, Antonino
2014-10-01
This paper shows the results of a scientific research in which a GNSS continuous monitoring system for earth-dam deformations has been developed, then, deformations have been related with reservoir water surface and level. The experiment was conducted near Bivona (Sicily, Italy), on the Castello dam (Magazzolo Lake). On the top of the dam three control points were placed and three GNSS permanent stations were installed. The three stations continuously transmitted data to the control centre of the University of Palermo. The former has been determined using freely available satellite data (specifically Landsat 7 SLC-Off) collected during the whole study period (DOYs 101 to 348 2011). Issues related with the un-scanned rows filling and to better distinguish water from land pixels on the shoreline. The aim of this work is various: first of all, we want to evaluate whether the GPS post processing techniques can provide static results comparable to other monitoring techniques, such as spirit levelling. The study could take a significant importance given that the Italian legislation until today does not provide for the use of this technology to manage or monitor dams displacements or other civil engineering constructions. The use of GPS data in structural monitoring could in fact reduce some management costs. Usually the conventional GPS monitoring methods, where a base station GPS receiver must be located near the dam, did not ensure that the accuracy of results have been independent from the displacement of the crown (top end of dam). In this paper, a new approach in the area of study of the GNSS permanent network has been engaged to solve these problems. Field-testing results show that the new GNSS approach has excellent performances, and the monitoring of different section of the dam could reveal important information on its deformation, that its not operationally possible to retrieve elsewhere. The post-processing accuracy positioning is around 1-5 mm for the deformations monitoring of the Castello dam. Displacements of different sections of the dam reveal different behaviour (in time and periodicity) that looks to be related with water surface (and level) retrieved from remote sensing.
The changes of cerebral hemodynamics during ketamine induced anesthesia in a rat model.
Bae, Jayyoung; Shin, Teo J; Kim, Seonghyun; Choi, Dong-Hyuk; Cho, Dongrae; Ham, Jinsil; Manca, Marco; Jeong, Seongwook; Lee, Boreom; Kim, Jae G
2018-05-25
Current electroencephalogram (EEG) based-consciousness monitoring technique is vulnerable to specific clinical conditions (eg, epilepsy and dementia). However, hemodynamics is the most fundamental and well-preserved parameter to evaluate, even under severe clinical situations. In this study, we applied near-infrared spectroscopy (NIRS) system to monitor hemodynamic change during ketamine-induced anesthesia to find its correlation with the level of consciousness. Oxy-hemoglobin (OHb) and deoxy-hemoglobin concentration levels were continuously acquired throughout the experiment, and the reflectance ratio between 730 and 850 nm was calculated to quantify the hemodynamic changes. The results showed double peaks of OHb concentration change during ketamine anesthesia, which seems to be closely related to the consciousness state of the rat. This finding suggests the possibility of NIRS based-hemodynamic monitoring as a supplementary parameter for consciousness monitoring, compensating drawbacks of EEG signal based monitoring. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
NASA Astrophysics Data System (ADS)
Larin, Kirill V.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.
2003-10-01
Approximately 14 million people in the USA and more than 140 million people worldwide suffer from Diabetes Mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for chemical analysis. Recently we proposed to use optical coherence tomography (OCT) for continuous noninvasive blood glucose sensing through skin. In this paper we tested the OCT technique for noninvasive monitoring of blood glucose concentration in lip tissue of New Zealand rabbits and Yucatan micropigs during glucose clamping experiments. Obtained results show good agreement with results obtained in skin studies, good correlation of changes in the OCT signal slope measured at the depth of 250 to 500 μm with changes in blood glucose concentration, and higher stability of the OCT data points than that obtained from skin.
Prévoteau, Antonin; Geirnaert, Annelies; Arends, Jan B A; Lannebère, Sylvain; Van de Wiele, Tom; Rabaey, Korneel
2015-07-01
Monitoring in vitro the metabolic activity of microorganisms aids bioprocesses and enables better understanding of microbial metabolism. Redox mediators can be used for this purpose via different electrochemical techniques that are either complex or only provide non-continuous data. Hydrodynamic chronoamperometry using a rotating disc electrode (RDE) can alleviate these issues but was seldom used and is poorly characterized. The kinetics of Faecalibacterium prausnitzii A2-165, a beneficial gut microbe, were determined using a RDE with riboflavin as redox probe. This butyrate producer anaerobically ferments glucose and reduces riboflavin whose continuous monitoring on a RDE provided highly accurate kinetic measurements of its metabolism, even at low cell densities. The metabolic reaction rate increased linearly over a broad range of cell concentrations (9 × 10(4) to 5 × 10(7) cells.mL(-1)). Apparent Michaelis-Menten kinetics was observed with respect to riboflavin (KM = 6 μM; kcat = 5.3 × 10(5) s(-1), at 37 °C) and glucose (KM = 6 μM; kcat = 2.4 × 10(5) s(-1)). The short temporal resolution allows continuous monitoring of fast cellular events such as kinetics inhibition with butyrate. Furthermore, we detected for the first time riboflavin reduction by another potential probiotic, Butyricicoccus pullicaecorum. The ability of the RDE for fast, accurate, simple and continuous measurements makes it an ad hoc tool for assessing bioprocesses at high resolution.
NASA Astrophysics Data System (ADS)
Hua, H.; Owen, S. E.; Yun, S.; Lundgren, P.; Fielding, E. J.; Agram, P.; Manipon, G.; Stough, T. M.; Simons, M.; Rosen, P. A.; Wilson, B. D.; Poland, M. P.; Cervelli, P. F.; Cruz, J.
2013-12-01
Space-based geodetic measurement techniques such as Interferometric Synthetic Aperture Radar (InSAR) and Continuous Global Positioning System (CGPS) are now important elements in our toolset for monitoring earthquake-generating faults, volcanic eruptions, hurricane damage, landslides, reservoir subsidence, and other natural and man-made hazards. Geodetic imaging's unique ability to capture surface deformation with high spatial and temporal resolution has revolutionized both earthquake science and volcanology. Continuous monitoring of surface deformation and surface change before, during, and after natural hazards improves decision-making from better forecasts, increased situational awareness, and more informed recovery. However, analyses of InSAR and GPS data sets are currently handcrafted following events and are not generated rapidly and reliably enough for use in operational response to natural disasters. Additionally, the sheer data volumes needed to handle a continuous stream of InSAR data sets also presents a bottleneck. It has been estimated that continuous processing of InSAR coverage of California alone over 3-years would reach PB-scale data volumes. Our Advanced Rapid Imaging and Analysis for Monitoring Hazards (ARIA-MH) science data system enables both science and decision-making communities to monitor areas of interest with derived geodetic data products via seamless data preparation, processing, discovery, and access. We will present our findings on the use of hybrid-cloud computing to improve the timely processing and delivery of geodetic data products, integrating event notifications from USGS to improve the timely processing for response, as well as providing browse results for quick looks with other tools for integrative analysis.
Schiepek, Günter K; Stöger-Schmidinger, Barbara; Aichhorn, Wolfgang; Schöller, Helmut; Aas, Benjamin
2016-01-01
Objective: The aim of this case report is to demonstrate the feasibility of a systemic procedure (synergetic process management) including modeling of the idiographic psychological system and continuous high-frequency monitoring of change dynamics in a case of dissociative identity disorder. The psychotherapy was realized in a day treatment center with a female client diagnosed with borderline personality disorder (BPD) and dissociative identity disorder. Methods: A three hour long co-creative session at the beginning of the treatment period allowed for modeling the systemic network of the client's dynamics of cognitions, emotions, and behavior. The components (variables) of this idiographic system model (ISM) were used to create items for an individualized process questionnaire for the client. The questionnaire was administered daily through an internet-based monitoring tool (Synergetic Navigation System, SNS), to capture the client's individual change process continuously throughout the therapy and after-care period. The resulting time series were reflected by therapist and client in therapeutic feedback sessions. Results: For the client it was important to see how the personality states dominating her daily life were represented by her idiographic system model and how the transitions between each state could be explained and understood by the activating and inhibiting relations between the cognitive-emotional components of that system. Continuous monitoring of her cognitions, emotions, and behavior via SNS allowed for identification of important triggers, dynamic patterns, and psychological mechanisms behind seemingly erratic state fluctuations. These insights enabled a change in management of the dynamics and an intensified trauma-focused therapy. Conclusion: By making use of the systemic case formulation technique and subsequent daily online monitoring, client and therapist continuously refer to detailed visualizations of the mental and behavioral network and its dynamics (e.g., order transitions). Effects on self-related information processing, on identity development, and toward a more pronounced autonomy in life (instead of feeling helpless against the chaoticity of state dynamics) were evident in the presented case and documented by the monitoring system.
Fine PM measurements: personal and indoor air monitoring.
Jantunen, M; Hänninen, O; Koistinen, K; Hashim, J H
2002-12-01
This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.
Esenaliev, Rinat O.
2017-01-01
Abstract. Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels. PMID:28444150
NASA Astrophysics Data System (ADS)
Esenaliev, Rinat O.
2017-09-01
Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels.
Beta/alpha continuous air monitor
Becker, Gregory K.; Martz, Dowell E.
1989-01-01
A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinguishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts.
NASA Technical Reports Server (NTRS)
Jiang, Jonathan H.; Wang, Ding-Yi; Romans, Larry J.; Ao, Chi O.; Schwartz, Michael J.; Stiller, Gabriele P.; von Clarmann, Thomas; Lopez-Puertas, Manuel; Funke, Bernd; Gil-Lopez, Sergio;
2003-01-01
A new generation GPS flight receiver was launched on the Argentinian satellite SAC-C in 2001. It has demonstrated the potential applicability for the continuous monitoring of the earth's atmosphere with radio occultation technology, and providing high vertical resolution profiles of temperature and water vapour data complementary to other sounding techniques.
Real-time imaging of subarachnoid hemorrhage in piglets with electrical impedance tomography.
Dai, Meng; Wang, Liang; Xu, Canhua; Li, Lianfeng; Gao, Guodong; Dong, Xiuzhen
2010-09-01
Subarachnoid hemorrhage (SAH) is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would significantly reduce the rate of disability and mortality, and improve the prognosis of the patients. Although the present medical imaging techniques generally have high sensitivity to identify bleeding, the use of an additional, non-invasive imaging technique capable of continuously monitoring SAH is required to prevent contingent bleeding or re-bleeding. In this study, electrical impedance tomography (EIT) was applied to detect the onset of SAH modeled on eight piglets in real time, with the subsequent process being monitored continuously. The experimental SAH model was introduced by one-time injection of 5 ml fresh autologous arterial blood into the cisterna magna. Results showed that resistivity variations within the brain caused by the added blood could be detected using the EIT method and may be associated not only with the resistivity difference among brain tissues, but also with variations of cerebrospinal fluid dynamics. In conclusion, EIT has unique potential for use in clinical practice to provide invaluable real-time neuroimaging data for SAH after the improvement of electrode design, anisotropic realistic modeling and instrumentation.
Rostami, Elham; Engquist, Henrik; Enblad, Per
2014-01-01
Ischemia is a common and deleterious secondary injury following traumatic brain injury (TBI). A great challenge for the treatment of TBI patients in the neurointensive care unit (NICU) is to detect early signs of ischemia in order to prevent further advancement and deterioration of the brain tissue. Today, several imaging techniques are available to monitor cerebral blood flow (CBF) in the injured brain such as positron emission tomography (PET), single-photon emission computed tomography, xenon computed tomography (Xenon-CT), perfusion-weighted magnetic resonance imaging (MRI), and CT perfusion scan. An ideal imaging technique would enable continuous non-invasive measurement of blood flow and metabolism across the whole brain. Unfortunately, no current imaging method meets all these criteria. These techniques offer snapshots of the CBF. MRI may also provide some information about the metabolic state of the brain. PET provides images with high resolution and quantitative measurements of CBF and metabolism; however, it is a complex and costly method limited to few TBI centers. All of these methods except mobile Xenon-CT require transfer of TBI patients to the radiological department. Mobile Xenon-CT emerges as a feasible technique to monitor CBF in the NICU, with lower risk of adverse effects. Promising results have been demonstrated with Xenon-CT in predicting outcome in TBI patients. This review covers available imaging methods used to monitor CBF in patients with severe TBI.
Rostami, Elham; Engquist, Henrik; Enblad, Per
2014-01-01
Ischemia is a common and deleterious secondary injury following traumatic brain injury (TBI). A great challenge for the treatment of TBI patients in the neurointensive care unit (NICU) is to detect early signs of ischemia in order to prevent further advancement and deterioration of the brain tissue. Today, several imaging techniques are available to monitor cerebral blood flow (CBF) in the injured brain such as positron emission tomography (PET), single-photon emission computed tomography, xenon computed tomography (Xenon-CT), perfusion-weighted magnetic resonance imaging (MRI), and CT perfusion scan. An ideal imaging technique would enable continuous non-invasive measurement of blood flow and metabolism across the whole brain. Unfortunately, no current imaging method meets all these criteria. These techniques offer snapshots of the CBF. MRI may also provide some information about the metabolic state of the brain. PET provides images with high resolution and quantitative measurements of CBF and metabolism; however, it is a complex and costly method limited to few TBI centers. All of these methods except mobile Xenon-CT require transfer of TBI patients to the radiological department. Mobile Xenon-CT emerges as a feasible technique to monitor CBF in the NICU, with lower risk of adverse effects. Promising results have been demonstrated with Xenon-CT in predicting outcome in TBI patients. This review covers available imaging methods used to monitor CBF in patients with severe TBI. PMID:25071702
A VCSEL based system for on-site monitoring of low level methane emission
NASA Astrophysics Data System (ADS)
Kannath, A.; Hodgkinson, J.; Gillard, R. G.; Riley, R. J.; Tatam, R. P.
2011-03-01
Continuous monitoring of methane emissions has assumed greater significance in the recent past due to increasing focus on global warming issues. Many industries have also identified the need for ppm level methane measurement as a means of gaining carbon credits. Conventional instruments based on NDIR spectroscopy are unable to offer the high selectivity and sensitivity required for such measurements. Here we discuss the development of a robust VCSEL based system for accurate low level measurements of methane. A possible area of application is the measurement of residual methane whilst monitoring the output of flare stacks and exhaust gases from methane combustion engines. The system employs a Wavelength Modulation Spectroscopy (WMS) scheme with second harmonic detection at 1651 nm. Optimum modulation frequency and ramp rates were chosen to maintain high resolution and fast response times which are vital for the intended application. Advanced data processing techniques were used to achieve long term sensitivity of the order of 10-5 in absorbance. The system is immune to cross interference from other gases and its inherent design features makes it ideal for large scale commercial production. The instrument maintains its calibration and offers a completely automated continuous monitoring solution for remote on site deployment.
Detecting Bioterrorism: Is Chemistry Enough?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omberg, Kristin M.
2014-03-13
This slide shows how most bioaerosol detection systems work. There is a lot of concern in the biothreat community, and in the federal government, about a large-scale aerosolized attack. Because of that, we’ve implemented environmental monitoring programs that use aerosol collectors to continuously monitor for the presence of threat agents in the air. Air samples are usually analyzed using PCR, which is one of the most effective analytical techniques we have for identifying DNA. Experiments and modeling have shown these systems are effective, and can warn public health of an impending crisis in time to mount an effective response.
MBE growth of vertical-cavity surface-emitting laser structure without real-time monitoring
NASA Astrophysics Data System (ADS)
Wu, C. Z.; Tsou, Y.; Tsai, C. M.
1999-05-01
Evaluation of producing a vertical-cavity surface-emitting laser (VCSEL) epitaxial structure by molecular beam epitaxy (MBE) without resorting to any real-time monitoring technique is reported. Continuous grading of Al xGa 1- xAs between x=0.12 to x=0.92 was simply achieved by changing the Al and Ga cell temperatures in no more than three steps per DBR period. Highly uniform DBR and VCSEL structures were demonstrated with a multi-wafer MBE system. Run-to-run standard deviation of reflectance spectrum center wavelength was 0.5% and 1.4% for VCSEL etalon wavelength.
Ude, Christian; Ben-Dov, Nadav; Jochums, André; Li, Zhaopeng; Segal, Ester; Scheper, Thomas; Beutel, Sascha
2016-05-01
The online monitoring of recombinant protein aggregate inclusion bodies during microbial cultivation is an immense challenge. Measurement of scattered and reflected light offers a versatile and non-invasive measurement technique. Therefore, we investigated two methods to detect the formation of inclusion bodies and monitor their production: (1) online 180° scattered light measurement (λ = 625 nm) using a sensor platform during cultivation in shake flask and (2) online measurement of the light reflective interference using a porous Si-based optical biosensor (SiPA). It could be shown that 180° scattered light measurement allows monitoring of alterations in the optical properties of Escherichia coli BL21 cells, associated with the formation of inclusion bodies during cultivation. A reproducible linear correlation between the inclusion body concentration of the non-fluorescent protein human leukemia inhibitory factor (hLIF) carrying a thioredoxin tag and the shift ("Δamp") in scattered light signal intensity was observed. This was also observed for the glutathione-S-transferase-tagged green fluorescent protein (GFP-GST). Continuous online monitoring of reflective interference spectra reveals a significant increase in the bacterium refractive index during hLIF production in comparison to a non-induced reference that coincide with the formation of inclusion bodies. These online monitoring techniques could be applied for fast and cost-effective screening of different protein expression systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Theodorakis, M.C.; Simpson, D.R.; Leung, D.M.
1983-02-01
A new method for monitoring tablet disintegration in vivo was developed. In this method, the tablets were labeled with a short-lived radionuclide, technetium 99m, and monitored by a gamma camera. Several innovations were introduced with this method. First, computer reconstruction algorithms were used to enhance the scintigraphic images of the disintegrating tablet in vivo. Second, the use of a four-pinhole collimator to acquire multiple views of the tablet resulted in high count rates and reduced acquisition times of the scintigraphic images. Third, the magnification of the scintigraphic images achieved by pinhole collimation led to significant improvement in resolution. Fourth, themore » radioinuclide was incorporated into the granulation so that the whole mass of the tablet was uniformly labeled with high levels of activity. This technique allowed the continuous monitoring of the disintegration process of tablets in vivo in experimental animals. Multiple pinhole collimation and the labeling process permitted the acquisition of quality scintigraphic images of the labeled tablet every 30 sec. The resolution of the method was tested in vitro and in vivo.« less
NASA Astrophysics Data System (ADS)
Cropper, Paul M.; Overson, Devon K.; Cary, Robert A.; Eatough, Delbert J.; Chow, Judith C.; Hansen, Jaron C.
2017-11-01
Particulate matter (PM) is among the most harmful air pollutants to human health, but due to its complex chemical composition is poorly characterized. A large fraction of PM is composed of organic compounds, but these compounds are not regularly monitored due to limitations in current sampling and analysis techniques. The Organic Aerosol Monitor (GC-MS OAM) combines a collection device with thermal desorption, gas chromatography and mass spectrometry to quantitatively measure the carbonaceous components of PM on an hourly averaged basis. The GC-MS OAM is fully automated and has been successfully deployed in the field. It uses a chemically deactivated filter for collection followed by thermal desorption and GC-MS analysis. Laboratory tests show that detection limits range from 0.2 to 3 ng for 16 atmospherically relevant compounds, with the possibility for hundreds more. The GC-MS OAM was deployed in the field for semi-continuous measurement of the organic markers, levoglucosan, dehydroabietic acid, and polycyclic aromatic hydrocarbons (PAHs) from January to March 2015. Results illustrate the significance of this monitoring technique to characterize the organic components of PM and identify sources of pollution.
Martínez-Arkarazo, I; Sarmiento, A; Maguregui, M; Castro, K; Madariaga, J M
2010-08-01
Any restoration performed on cultural heritage artworks must guarantee a low impact on the treated surfaces. Although completely risk-free methods do not exist, the use of tailor-made procedures and the continuous monitoring by portable instrumentation is surely one of the best approaches to conduct a modern restoration process. In this work, a portable Raman monitoring, combined sometimes with spectroscopic techniques providing the elemental composition, is the key analysis technique in the three-step restoration protocol proposed: (a) in situ analysis of the surface to be treated (original composition and degradation products/pollutants) and the cleaning agents used as extractants, (b) the thermodynamic study of the species involved in the treatment in order to design a suitable restoration method and (c) application and monitoring of the treatment. Two cleaning operations based on new technologies were studied and applied to two artworks on mineral supports: a wall painting affected by nitrate impact, and a black crusted stone (chalk) altarpiece. Raman bands of nitrate and gypsum, respectively, decreased after the step-by-step operations in each case, which helped restorers to decide when the treatment was concluded, thus avoiding any further damage to the treated surface of the artworks.
40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1250 What is my schedule for evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13...
Surface-enhanced Raman for monitoring toxins in water
NASA Astrophysics Data System (ADS)
Spencer, Kevin M.; Sylvia, James M.; Clauson, Susan L.; Bertone, Jane F.; Christesen, Steven D.
2004-02-01
Protection of the drinking water supply from a terrorist attack is of critical importance. Since the water supply is vast, contamination prevention is difficult. Therefore, rapid detection of contaminants, whether a military chemical/biological threat, a hazardous chemical spill, naturally occurring toxins, or bacterial build-up is a priority. The development of rapid environmentally portable and stable monitors that allow continuous monitoring of the water supply is ideal. EIC Laboratories has been developing Surface-Enhanced Raman Spectroscopy (SERS) to detect chemical agents, toxic industrial chemicals (TICs), viruses, cyanotoxins and bacterial agents. SERS is an ideal technique for the Joint Service Agent Water Monitor (JSAWM). SERS uses the enhanced Raman signals observed when an analyte adsorbs to a roughened metal substrate to enable trace detection. Proper development of the metal substrate will optimize the sensitivity and selectivity towards the analytes of interest.
Failure Control Techniques for the SSME
NASA Technical Reports Server (NTRS)
Taniguchi, M. H.
1987-01-01
Since ground testing of the Space Shuttle Main Engine (SSME) began in 1975, the detection of engine anomalies and the prevention of major damage have been achieved by a multi-faceted detection/shutdown system. The system continues the monitoring task today and consists of the following: sensors, automatic redline and other limit logic, redundant sensors and controller voting logic, conditional decision logic, and human monitoring. Typically, on the order of 300 to 500 measurements are sensed and recorded for each test, while on the order of 100 are used for control and monitoring. Despite extensive monitoring by the current detection system, twenty-seven (27) major incidents have occurred. This number would appear insignificant compared with over 1200 hot-fire tests which have taken place since 1976. However, the number suggests the requirement for and future benefits of a more advanced failure detection system.
40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring...
Nondestructive Testing of Overhead Transmission LINES—NUMERICAL and Experimental Investigation
NASA Astrophysics Data System (ADS)
Kulkarni, S.; Hurlebaus, S.
2009-03-01
Overhead transmission lines are periodically inspected using both on-ground and helicopter-aided visual inspection. Factors including sun glare, cloud cover, close proximity to power lines and the rapidly changing visual circumstances make airborne inspection of power lines a particularly hazardous task. In this study, a finite element model is developed that can be used to create the theoretical dispersion curves of an overhead transmission line. The numerical results are then verified with experimental test using a non-contact and broadband laser detection technique. The methodology developed in this study can be further extended to a continuous monitoring system and be applied to other cable monitoring applications, such as bridge cable monitoring, which would otherwise put human inspectors at risk.
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...
Development of a thick film PZT foil sensor for use in structural health monitoring applications.
Pickwell, Andrew J; Dorey, Robert A; Mba, David
2013-02-01
Acoustic emission (AE) monitoring is a technique of growing interest in the field of nondestructive testing (NDT). The use of AE devices to monitor the health of structural components is currently limited by the cost of AE equipment, which prohibits the permanent placement of AE devices on structures for the purposes of continuous monitoring and the monitoring of areas with limited access. Micro electromechanical systems (MEMS) can provide solutions to these problems. We present the manufacture of a 4.4-μm-thick lead zirconate titanate (PZT) film on a 110-μm-thick titanium foil substrate for use as an AE sensor. The thick-film sensor is benchmarked against commercially available AE sensors in static and dynamic monitoring applications. The thick-film AE device is found to perform well in the detection of AE in static applications. A low signal-to-noise ratio is found to prohibit the detection of AE in a dynamic application.
Microimaging of transient guest profiles to monitor mass transfer in nanoporous materials
NASA Astrophysics Data System (ADS)
Kärger, Jörg; Binder, Tomas; Chmelik, Christian; Hibbe, Florian; Krautscheid, Harald; Krishna, Rajamani; Weitkamp, Jens
2014-04-01
The intense interactions of guest molecules with the pore walls of nanoporous materials is the subject of continued fundamental research. Stimulated by their thermal energy, the guest molecules in these materials are subject to a continuous, irregular motion, referred to as diffusion. Diffusion, which is omnipresent in nature, influences the efficacy of nanoporous materials in reaction and separation processes. The recently introduced techniques of microimaging by interference and infrared microscopy provide us with a wealth of information on diffusion, hitherto inaccessible from commonly used techniques. Examples include the determination of surface barriers and the sticking coefficient's analogue, namely the probability that, on colliding with the particle surface, a molecule may continue its diffusion path into the interior. Microimaging is further seen to open new vistas in multicomponent guest diffusion (including the detection of a reversal in the preferred diffusion pathways), in guest-induced phase transitions in nanoporous materials and in matching the results of diffusion studies under equilibrium and non-equilibrium conditions.
NASA Astrophysics Data System (ADS)
Chakrabartty, Shantanu; Feng, Tao; Aono, Kenji
2013-04-01
A key challenge in structural health monitoring (SHM) sensors embedded inside civil structures is that elec- tronics need to operate continuously such that mechanical events of interest can be detected and appropriately analyzed. Continuous operation however requires a continuous source of energy which cannot be guaranteed using conventional energy scavenging techniques. The paper describes a hybrid energy scavenging SHM sensor which experiences zero down-time in monitoring mechanical events of interest. At the core of the proposed sensor is an analog floating-gate storage technology that can be precisely programmed at nano-watt and pico- watt power levels. This facilitates self-powered, non-volatile data logging of the mechanical events of interest by scavenging energy directly from the mechanical events itself. Remote retrieval of the stored data is achieved using a commercial off-the-shelf Gen-2 radio-frequency identification (RFID) reader which periodically reads an electronic product code (EPC) that encapsulates the sensor data. The Gen-2 interface also facilitates in simultaneous remote access to multiple sensors and also facilitates in determining the range and orientation of the sensor. The architecture of the sensor is based on a token-ring topology which enables sensor channels to be dynamically added or deleted through software control.
NASA Astrophysics Data System (ADS)
Yhokha, Akano; Goswami, Pradeep K.; Chang, Chung-Pai; Yen, Jiun-Yee; Ching, Kuo-En; Aruche, K. Manini
2018-02-01
Orogenic movements and sub-tropical climate have rendered the slopes of the Himalayan region intensely deformed and weathered. As a result, the incidences of slope failure are quite common all along the Himalayan region. The Lesser Himalayan terrane is particularly vulnerable to mass-movements owing to geological fragility, and many parts of it are bearing a high-risk of associated disaster owing to the high population density. An important step towards mitigation of such disasters is the monitoring of slope movement. Towards this, the Persistent Scatterer Interferometry (PSI) technique can be applied. In the present study, the PSI technique is employed in Lesser Himalayan town of Nainital in Uttarakhand state of India to decipher and monitor slope movements. A total of 15 multi-date ENVISAT ASAR satellite images, acquired during August 2008 to August 2010 period, were subjected to PSI, which revealed a continuous creep movement along the hillslopes located towards the eastern side of the Nainital lake. The higher reaches of the hill seem to be experiencing accelerated creep of {˜ }21 mm/year, which decreases downslope to {˜ }5 mm/year. Based on spatial pattern of varying PSI Mean LOS Velocity (MLV) values, high (H), moderate (M), low (L) and very low (S) creeping zones have been delineated in the hillslopes. Given the long history of mass movements and continuously increasing anthropogenic activities in Nainital, these results call for immediate measures to avert any future disaster in the town.
Broadband geophysical time series data from a stressed environment
NASA Astrophysics Data System (ADS)
Pun, W.; Saleh, R.; Zwaan, D.; Milkereit, B.; Valley, B.; Pilz, M.; Milkereit, C.; Milkereit, R.
2011-12-01
As classical exploration geophysical tools and techniques find new application in time lapse and monitoring studies, a fresh look at the performance and repeatability of various geophysical techniques is worth to take a closer look. We used an active, deep mine site close to Sudbury (Canada) for 3D deployment of broadband geophysical sensors for passive monitoring and detecting anomalous regions in the earth based on physical rock properties. In addition, we conducted controlled source experiments to evaluate repeatability of geophysical sources. To extend from detection to monitoring, continuous repeated measurements are necessary over a long period of time. If a controlled source is stable, the convolution problem is simplified such that any variation in the geophysical data is an effect of the earth's response. Repeated measurements are important for in-mine use to provide a better insight of stress and strain changes due to natural events and mining processes. The development, build-up and redistribution of stress lead to rock failures that can have disastrous consequences if they occur in an uncontrolled manner. In this project, different continuous and repeated in-situ geophysical measurements from a deep underground mine were analyzed to validate the feasibility of in-mine monitoring. Data acquisition tests covered both active and passive methods: gravity meter, fibre optic strain meters, fixed and portable three-component seismic arrays, EM induction coils and borehole based DC/IP resistivity sensors. The newly acquired data cover a wide range of frequencies which allow the study of short- and long-period events, ranging from 10-5 Hz to 10 kHz. Earth tides, global seismic events, tremors, acoustic emissions (microseismic events) and blasts were recorded within a 3D volume.
Caduff, A; Dewarrat, F; Talary, M; Stalder, G; Heinemann, L; Feldman, Yu
2006-12-15
The aim of this work was to evaluate the performance of a novel non-invasive continuous glucose-monitoring system based on impedance spectroscopy (IS) in patients with diabetes. Ten patients with type 1 diabetes (mean+/-S.D., age 28+/-8 years, BMI 24.2+/-3.2 kg/m(2) and HbA(1C) 7.3+/-1.6%) and five with type 2 diabetes (age 61+/-8 years, BMI 27.5+/-3.2 kg/m(2) and HbA(1C) 8.3+/-1.8%) took part in this study, which comprised a glucose clamp experiment followed by a 7-day outpatient evaluation. The measurements obtained by the NI-CGMD and the reference blood glucose-measuring techniques were evaluated using retrospective data evaluation procedures. Under less controlled outpatient conditions a correlation coefficient of r=0.640 and a standard error of prediction (SEP) of 45 mg dl(-1) with a total of 590 paired glucose measurements was found (versus r=0.926 and a SEP of 26 mg dl(-1) under controlled conditions). Clark error grid analyses (EGA) showed 56% of all values in zone A, 37% in B and 7% in C-E. In conclusion, these results indicate that IS in the used technical setting allows retrospective, continuous and truly non-invasive glucose monitoring under defined conditions for patients with diabetes. Technical advances and developments are needed to expand on this concept to bring the results from the outpatient study closer to those in the experimental section of the study. Further studies will not only help to evaluate the performance and limitations of using such a technique for non non-invasive glucose monitoring but also help to verify technical extensions towards a IS-based concept that offers improved performance under real life operating conditions.
NASA Astrophysics Data System (ADS)
E. Romero, Carlos; De Saro, Robert
Coal is a non-uniform material with large inherent variability in composition, and other important properties, such as calorific value and ash fusion temperature. This quality variability is very important when coal is used as fuel in steam generators, since it affects boiler operation and control, maintenance and availability, and the extent and treatment of environmental pollution associated with coal combustion. On-line/in situ monitoring of coal before is fed into a boiler is a necessity. A very few analytical techniques like X-ray fluorescence and prompt gamma neutron activation analysis are available commercially with enough speed and sophistication of data collection for continuous coal monitoring. However, there is still a need for a better on-line/in situ technique that has higher selectivity, sensitivity, accuracy and precision, and that is safer and has a lower installation and operating costs than the other options. Laser induced breakdown spectroscopy (LIBS) is ideal for coal monitoring in boiler applications as it need no sample preparation, it is accurate and precise it is fast, and it can detect all of the elements of concern to the coal-fired boiler industry. LIBS data can also be adapted with advanced data processing techniques to provide real-time information required by boiler operators nowadays. This chapter summarizes development of LIBS for on-line/in situ coal applications in utility boilers.
Zijlstra, Carolien; Lund, Ivar; Justesen, Annemarie F; Nicolaisen, Mogens; Jensen, Peter Kryger; Bianciotto, Valeria; Posta, Katalin; Balestrini, Raffaella; Przetakiewicz, Anna; Czembor, Elzbieta; van de Zande, Jan
2011-06-01
The possibility of combining novel monitoring techniques and precision spraying for crop protection in the future is discussed. A generic model for an innovative crop protection system has been used as a framework. This system will be able to monitor the entire cropping system and identify the presence of relevant pests, diseases and weeds online, and will be location specific. The system will offer prevention, monitoring, interpretation and action which will be performed in a continuous way. The monitoring is divided into several parts. Planting material, seeds and soil should be monitored for prevention purposes before the growing period to avoid, for example, the introduction of disease into the field and to ensure optimal growth conditions. Data from previous growing seasons, such as the location of weeds and previous diseases, should also be included. During the growing season, the crop will be monitored at a macroscale level until a location that needs special attention is identified. If relevant, this area will be monitored more intensively at a microscale level. A decision engine will analyse the data and offer advice on how to control the detected diseases, pests and weeds, using precision spray techniques or alternative measures. The goal is to provide tools that are able to produce high-quality products with the minimal use of conventional plant protection products. This review describes the technologies that can be used or that need further development in order to achieve this goal. Copyright © 2011 Society of Chemical Industry.
Beta/alpha continuous air monitor
Becker, G.K.; Martz, D.E.
1988-06-27
A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.
Shih, Jeanne-Louise; Kobayashi, Makiko; Jen, Cheng-Kuei
2010-09-01
Piezoelectric films have been deposited by a sol-gel spray technique onto 75-μm-thick titanium and stainless steel (SS) membranes and have been fabricated into flexible ultrasonic transducers (FUTs). FUTs using titanium membranes were glued and those using SS membranes brazed onto steel pipes, procedures that serve as on-site installation techniques for the purpose of offering continuous thickness monitoring capabilities at up to 490 °C. At 150 °C, the thickness measurement accuracy of a pipe with an outer diameter of 26.6 mm and a wall thickness of 2.5 mm was estimated to be 26 μm and the center frequency of the FUT was 10.8 MHz. It is demonstrated that the frequency bandwidth of the FUTs and SNR of signals using glue or brazing materials as high-temperature couplant for FUTs are sufficient to inspect the steel pipes even with a 2.5 mm wall thickness.
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems...
NASA Astrophysics Data System (ADS)
Huang, H. H.; Hsu, Y. J.; Kuo, C. Y.; Chen, C. C.; Kuo, L. W.; Chen, R. F.; Lin, C. R.; Lin, P. P.; Lin, C. W.; Lin, M. L.; Wang, K. L.
2017-12-01
A unique landslide monitoring project integrating multidisciplinary geophysics experiments such as GPS, inclinometer, piezometer, and spontaneous potential log has been established at Lantai, Ilan area to investigating the possible detachment depth range and the physical mechanism of a slowly creeping landslide. In parallel with this, a lately deployed local seismic network also lends an opportunity to employ the passive seismic imaging technique to detect the time-lapse changes of seismic velocity in and around the landslide area. Such technique that retrieves Green's functions by cross-correlation of continuous ambient noise has opened new opportunities to seismologically monitoring the environmental and tectonic events such as ground water variation, magma intrusion under volcanos, and co-seismic medium damage in recent years. Integrating these geophysical observations, we explore the primary controls of derived seismic velocity changes and especially the hydrological response of the landslide to the passage of Megi typhoon in the last September 2016, which could potentially further our understanding of the dynamic system of landslides and in turn help the hazard mitigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohd, Shukri; Holford, Karen M.; Pullin, Rhys
2014-02-12
Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup usingmore » H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure.« less
Real-time understanding of lignocellulosic bioethanol fermentation by Raman spectroscopy
2013-01-01
Background A substantial barrier to commercialization of lignocellulosic ethanol production is a lack of process specific sensors and associated control strategies that are essential for economic viability. Current sensors and analytical techniques require lengthy offline analysis or are easily fouled in situ. Raman spectroscopy has the potential to continuously monitor fermentation reactants and products, maximizing efficiency and allowing for improved process control. Results In this paper we show that glucose and ethanol in a lignocellulosic fermentation can be accurately monitored by a 785 nm Raman spectroscopy instrument and novel immersion probe, even in the presence of an elevated background thought to be caused by lignin-derived compounds. Chemometric techniques were used to reduce the background before generating calibration models for glucose and ethanol concentration. The models show very good correlation between the real-time Raman spectra and the offline HPLC validation. Conclusions Our results show that the changing ethanol and glucose concentrations during lignocellulosic fermentation processes can be monitored in real-time, allowing for optimization and control of large scale bioconversion processes. PMID:23425590
Adaptive neural network/expert system that learns fault diagnosis for different structures
NASA Astrophysics Data System (ADS)
Simon, Solomon H.
1992-08-01
Corporations need better real-time monitoring and control systems to improve productivity by watching quality and increasing production flexibility. The innovative technology to achieve this goal is evolving in the form artificial intelligence and neural networks applied to sensor processing, fusion, and interpretation. By using these advanced Al techniques, we can leverage existing systems and add value to conventional techniques. Neural networks and knowledge-based expert systems can be combined into intelligent sensor systems which provide real-time monitoring, control, evaluation, and fault diagnosis for production systems. Neural network-based intelligent sensor systems are more reliable because they can provide continuous, non-destructive monitoring and inspection. Use of neural networks can result in sensor fusion and the ability to model highly, non-linear systems. Improved models can provide a foundation for more accurate performance parameters and predictions. We discuss a research software/hardware prototype which integrates neural networks, expert systems, and sensor technologies and which can adapt across a variety of structures to perform fault diagnosis. The flexibility and adaptability of the prototype in learning two structures is presented. Potential applications are discussed.
40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
Continuous monitoring of bacterial attachment
NASA Technical Reports Server (NTRS)
Koeing, D. W.; Mishra, S. K.; Pierson, D. L.
1994-01-01
A major concern with the Space Station Freedom (SSF) water supply system is the control of longterm microbial contamination and biofilm development in the water storage and distribution systems. These biofilms have the potential for harboring pathogens as well as microbial strains containing resistance factors that could negatively influence crew health. The proposed means for disinfecting the water system on SSF (iodine) may encourage the selection of resistant strains. In fact, biofilm bacteria were observed in water lines from the Space Shuttle Columbia (OV-102); therefore, an alternative remediation method is required to disinfect spacecraft water lines. A thorough understanding of colonization events and the physiological parameters that will influence bacteria adhesion is required. The limiting factor for development of this technology is the ability to continuously monitor adhesion events and the effects of biocides on sessile bacteria. Methods were developed to allow bacterial adhesion and subsequent biocidal treatment to be monitored continuously. This technique couples automated image analysis with a continuous flow of a bacterial suspension through an optical flow cell. A strain of Pseudomonas cepacia isolated from the water supply of the Space Shuttle Discovery (OV-103) during STS-39 was grown in a nitrogen-limited continuous culture. This culture was challenged continuously with iodine during growth, and the adhesion characteristics of this strain was measure with regard to flow rate. Various biocides (ozone, hypochlorite, and iodine) were added to the flow stream to evaluate how well each chemical removed the bacteria. After biocide treatment, a fresh bacterial suspension was introduced into the flow cell, and the attachment rate was evaluated on the previously treated surface. This secondary fouling was again treated with biocide to determine the efficacy of multiple batch chemical treatments in removing biofilm.
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
Puchades, R.; Maquieira, A.; Atienza, J.; Herrero, M. A.
1990-01-01
Flow injection analysis (FIA) has emerged as an increasingly used laboratory tool in chemical analysis. Employment of the technique for on-line sample treatment and on-line measurement in chemical process control is a growing trend. This article reviews the recent applications of FlA. Most papers refer to on-line sample treatment. Although FIA is very well suited to continuous on-line process monitoring, few examples have been found in this areamost of them have been applied to water treatment or fermentation processes. PMID:18925271
Self-control program in the treatment of obesity.
Rosen, L W
1981-06-01
In a pilot study utilizing self-control techniques for the purpose of modifying the cue-reactive eating habits of obese patients, three subjects maintained a continuous weight loss throughout the first year of treatment. Techniques included goal setting, self-monitoring, brief delay and self-confrontation prior to eating unauthorized food and direct observation of oneself in a mirror when eating unauthorized food. All patients are expected to remain in treatment for the foreseeable future with no termination of the program despite apparent success with regard to control of their feeding disturbance. The rationale for this approach is discussed.
NASA Astrophysics Data System (ADS)
Chtouki, Toufik; Vergne, Jerome; Provost, Floriane; Malet, Jean-Philippe; Burtin, Arnaud; Hibert, Clément
2017-04-01
The Super-Sauze landslide is located on the southern part of the Barcelonnette Basin (French Alps) and has developed in a soft clay-shale environment. It is one of the four sites continuously monitored through a wide variety of geophysical and hydro-geological techniques in the framework of the OMIV French national landslide observatory. From early June to mid-July 2016, a temporary dense seismic array has been installed in the most active part of the landslide and at its surroundings. 50 different sites with an average inter-station distance of 50m have been instrumented with 150 miniaturized and autonomous seismic stations (Zland nodes), allowing a continuous record of the seismic signal at frequencies higher than 0.2Hz over an almost regular grid. Concurrently, a Ground-Based InSAR device allowed for a precise and continuous monitoring of the surface deformation. Overall, this experiment is intended to better characterize the spatio-temporal evolution of the deformation processes related to various type of forcing. We analyze the continuous records of ambient seismic noise recorded by the dense array. Using power spectral densities, we characterize the various types of natural and anthropogenic seismic sources, including the effect of water turbulence and bedload transport in the small nearby torrents. We also compute the correlation of the ambient diffuse seismic noise in various frequency bands for the 2448 station pairs to recover the empirical Green functions between them. The temporal evolution of the coda part of these noise correlation functions allows monitoring and localizing shear wave velocity variations in the sliding mass. Here we present some preliminary results of this analysis and compare the seismic variations to meteorological data and surface deformation.
NASA Astrophysics Data System (ADS)
Sung, Wen-Pei; Shih, Ming-Hsiang
2016-04-01
Global warming phenomena are increasingly serious, the El Niño and La Niña continue to occur repeatedly, causing the irregular drought and flood problem repeatedly. Mountain form of Taiwan is steep and storage ability of rainwater is insufficient to supply the livelihood of people and usage of industry which need to rely on rainwater reservoir. Thus, to ensure the water supply and self-reliance energy supply, one of ways to keep water resource is to build reservoir. Nevertheless, Taiwan is located on Pacific seismic belt; additionally, geological conditions are not fine, over-developed in the hills lead to more natural disasters in the future. Thus, strong shakes and typhoons which caused a degree of severe landslides around dam lead to reduce catchment of dam to result in affecting the safety of dam. Otherwise, the cracks and rusts in dam, induced by the defects of material, bad construction and seismic excitation respectively, thus, the mechanics phenomena of dam and its affiliated structures with crack are probing into the cause of stress concentration, induced high crack increase rate, affect the safety and usage of dam. This research is aimed at the safety evaluation technique of dam and its affiliated structures to develop three dimensional digital image correlation techniques for monitoring the safety of dam and its affiliated structures. Namely, developing the unmanned mobile on two axis of digital image correlation method is to detect the digital images from geometric scanning techniques for dam structure. This developed technique combined with Unmanned Aerial Vehicle (UAV) to develop the near filed scanning and monitoring techniques for local deformation and cracks on dam and its affiliated structures.
NASA Astrophysics Data System (ADS)
Prévoteau, Antonin; Geirnaert, Annelies; Arends, Jan B. A.; Lannebère, Sylvain; van de Wiele, Tom; Rabaey, Korneel
2015-07-01
Monitoring in vitro the metabolic activity of microorganisms aids bioprocesses and enables better understanding of microbial metabolism. Redox mediators can be used for this purpose via different electrochemical techniques that are either complex or only provide non-continuous data. Hydrodynamic chronoamperometry using a rotating disc electrode (RDE) can alleviate these issues but was seldom used and is poorly characterized. The kinetics of Faecalibacterium prausnitzii A2-165, a beneficial gut microbe, were determined using a RDE with riboflavin as redox probe. This butyrate producer anaerobically ferments glucose and reduces riboflavin whose continuous monitoring on a RDE provided highly accurate kinetic measurements of its metabolism, even at low cell densities. The metabolic reaction rate increased linearly over a broad range of cell concentrations (9 × 104 to 5 × 107 cells.mL-1). Apparent Michaelis-Menten kinetics was observed with respect to riboflavin (KM = 6 μM kcat = 5.3×105 s-1, at 37 °C) and glucose (KM = 6 μM kcat = 2.4 × 105 s-1). The short temporal resolution allows continuous monitoring of fast cellular events such as kinetics inhibition with butyrate. Furthermore, we detected for the first time riboflavin reduction by another potential probiotic, Butyricicoccus pullicaecorum. The ability of the RDE for fast, accurate, simple and continuous measurements makes it an ad hoc tool for assessing bioprocesses at high resolution.
Noise-based seismic monitoring of the Campi Flegrei caldera
NASA Astrophysics Data System (ADS)
Zaccarelli, Lucia; Bianco, Francesca
2017-03-01
The Campi Flegrei caldera is one of the highest risk volcanic fields worldwide, because of its eruptive history and the large population hosted within the caldera. It experiences bradiseismic crises: sudden uplift with low energetic seismic swarm occurrences. No seismicity is recorded out of these deformation rate changes. Therefore, a continuous seismic monitoring of the caldera is possible only by means of the ambient seismic noise. We apply a noise-based seismic monitoring technique to the cross correlations of 5 year recordings at the mobile seismic network. The resulting relative velocity variations are compared to the temporal behavior of the geophysical and geochemical observations routinely sampled at Campi Flegrei. We discriminate between two kinds of crustal stress field variations acting at different timescales. They are related to a possible magmatic intrusion and to the gradual heating of the hydrothermal system, respectively. This study sets up the basis for future volcano monitoring strategies.
Telefetalcare: a first prototype of a wearable fetal electrocardiograph.
Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G
2011-01-01
Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.
Non-invasive heart rate monitoring system using giant magneto resistance sensor.
Kalyan, Kubera; Chugh, Vinit Kumar; Anoop, C S
2016-08-01
A simple heart rate (HR) monitoring system designed and developed using the Giant Magneto-Resistance (GMR) sensor is presented in this paper. The GMR sensor is placed on the wrist of the human and it provides the magneto-plethysmographic signal. This signal is processed by the simple analog and digital instrumentation stages to render the heart rate indication. A prototype of the system has been built and test results on 26 volunteers have been reported. The error in HR estimation of the system is merely 1 beat per minute. The performance of the system when layer of cloth is present between the sensor and the human body is investigated. The capability of the system as a HR variability estimator has also been established through experimentation. The proposed technique can be used as an efficient alternative to conventional HR monitors and is well suited for remote and continuous monitoring of HR.
Remote Safety Monitoring for Elderly Persons Based on Omni-Vision Analysis
Xiang, Yun; Tang, Yi-ping; Ma, Bao-qing; Yan, Hang-chen; Jiang, Jun; Tian, Xu-yuan
2015-01-01
Remote monitoring service for elderly persons is important as the aged populations in most developed countries continue growing. To monitor the safety and health of the elderly population, we propose a novel omni-directional vision sensor based system, which can detect and track object motion, recognize human posture, and analyze human behavior automatically. In this work, we have made the following contributions: (1) we develop a remote safety monitoring system which can provide real-time and automatic health care for the elderly persons and (2) we design a novel motion history or energy images based algorithm for motion object tracking. Our system can accurately and efficiently collect, analyze, and transfer elderly activity information and provide health care in real-time. Experimental results show that our technique can improve the data analysis efficiency by 58.5% for object tracking. Moreover, for the human posture recognition application, the success rate can reach 98.6% on average. PMID:25978761
Structural Monitoring and Field Test for Kao Ping Hsi Cable-Stayed Bridge in Taiwan
NASA Astrophysics Data System (ADS)
Chen, Chern-Hwa
2010-05-01
This work applies system identification techniques to analyze the measured data from structural monitoring system and field test for Kao Ping Hsi cable-stayed bridge in Taiwan. The continuous wavelet transform algorithm can be used to identify the dynamic characteristics of the cable-stayed bridge under environmental vibration. The identified results with traffic flow were compared with those obtained from ambient vibration test. The excellent agreement both the identified results from different traffic conditions indicates that the traffic flow would not significantly change the natural frequencies of the cable-stayed bridge. The modal parameters identified from the field vibration test will be compared with those used in the finite element analysis. The results obtained herein will be used as the damage detection for monitoring the long-term safety of the Kao Ping Hsi cable-stayed bridge by using structural monitoring system.
40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...
40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...
40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...
40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Optical glucose monitoring using vertical cavity surface emitting lasers (VCSELs)
NASA Astrophysics Data System (ADS)
Talebi Fard, Sahba; Hofmann, Werner; Talebi Fard, Pouria; Kwok, Ezra; Amann, Markus-Christian; Chrostowski, Lukas
2009-08-01
Diabetes Mellitus is a common chronic disease that has become a public health issue. Continuous glucose monitoring improves patient health by stabilizing the glucose levels. Optical methods are one of the painless and promising methods that can be used for blood glucose predictions. However, having accuracies lower than what is acceptable clinically has been a major concern. Using lasers along with multivariate techniques such as Partial Least Square (PLS) can improve glucose predictions. This research involves investigations for developing a novel optical system for accurate glucose predictions, which leads to the development of a small, low power, implantable optical sensor for diabetes patients.
New approaches to some methodological problems of meteor science
NASA Technical Reports Server (NTRS)
Meisel, David D.
1987-01-01
Several low cost approaches to continuous radioscatter monitoring of the incoming meteor flux are described. Preliminary experiments were attempted using standard time frequency stations WWVH and CHU (on frequencies near 15 MHz) during nighttime hours. Around-the-clock monitoring using the international standard aeronautical beacon frequency of 75 MHz was also attempted. The techniques are simple and can be managed routinely by amateur astronomers with relatively little technical expertise. Time series analysis can now be performed using relatively inexpensive microcomputers. Several algorithmic approaches to the analysis of meteor rates are discussed. Methods of obtaining optimal filter predictions of future meteor flux are also discussed.
NASA Astrophysics Data System (ADS)
Castellote, Marta; Llorente, I.; Andrade, Carmen; Turrillas, X.; Alonso, Cruz; Campo, Javier
2006-11-01
Realkalisation is an electrochemical technique for repairing concrete structures damaged by rebar corrosion due to carbonation. The treatment aims at restoring alkalinity of the concrete by application of a continuous current between the rebar, acting as a cathode, and an external auxiliary electrode placed in a carbonate solution and connected to a positive pole of a power supply. Here we report the application of neutron diffraction in the in situ monitoring of a realkalisation treatment, analysing at the same time the development of the electro-osmotic flux and the microstructural variations in the surroundings of the rebar.
Studying the Variability of Bright Stars with the CONCAM Sky Monitoring Network
NASA Astrophysics Data System (ADS)
Pereira, W. E.; Nemiroff, R. J.; Rafert, J. B.; Perez-Ramirez, D.
2001-12-01
CONCAMs have now been deployed at some of the world's major observatories including KPNO in Arizona, Mauna Kea in Hawaii, and Wise Observatory in Israel. Data from these mobile, inexpensive and continuous sky cameras, consisting of a fish-eye lens mated to a CCD camera and run by a laptop, has been ever-increasing. Initial efforts to carry out photometric analysis of CONCAM fits images have now been fortified by a more automated technique of analyzing this data. Results of such analyses - variability of several bright stars, in particular, are presented, as well as the use of these cameras as cloud monitors to remote observers.
Remote sensing of environmental impact of land use activities
NASA Technical Reports Server (NTRS)
Paul, C. K.
1977-01-01
The capability to monitor land cover, associated in the past with aerial film cameras and radar systems, was discussed in regard to aircraft and spacecraft multispectral scanning sensors. A proposed thematic mapper with greater spectral and spatial resolutions for the fourth LANDSAT is expected to usher in new environmental monitoring capability. In addition, continuing improvements in image classification by supervised and unsupervised computer techniques are being operationally verified for discriminating environmental impacts of human activities on the land. The benefits of employing remote sensing for this discrimination was shown to far outweigh the incremental costs of converting to an aircraft-satellite multistage system.
Forward voltage short-pulse technique for measuring high power laser array junction temperature
NASA Technical Reports Server (NTRS)
Meadows, Byron L. (Inventor); Amzajerdian, Frazin (Inventor); Barnes, Bruce W. (Inventor); Baker, Nathaniel R. (Inventor)
2012-01-01
The present invention relates to a method of measuring the temperature of the P-N junction within the light-emitting region of a quasi-continuous-wave or pulsed semiconductor laser diode device. A series of relatively short and low current monitor pulses are applied to the laser diode in the period between the main drive current pulses necessary to cause the semiconductor to lase. At the sufficiently low current level of the monitor pulses, the laser diode device does not lase and behaves similar to an electronic diode. The voltage across the laser diode resulting from each of these low current monitor pulses is measured with a high degree of precision. The junction temperature is then determined from the measured junction voltage using their known linear relationship.
Fiber-Optic Surface Temperature Sensor Based on Modal Interference.
Musin, Frédéric; Mégret, Patrice; Wuilpart, Marc
2016-07-28
Spatially-integrated surface temperature sensing is highly useful when it comes to controlling processes, detecting hazardous conditions or monitoring the health and safety of equipment and people. Fiber-optic sensing based on modal interference has shown great sensitivity to temperature variation, by means of cost-effective image-processing of few-mode interference patterns. New developments in the field of sensor configuration, as described in this paper, include an innovative cooling and heating phase discrimination functionality and more precise measurements, based entirely on the image processing of interference patterns. The proposed technique was applied to the measurement of the integrated surface temperature of a hollow cylinder and compared with a conventional measurement system, consisting of an infrared camera and precision temperature probe. As a result, the optical technique is in line with the reference system. Compared with conventional surface temperature probes, the optical technique has the following advantages: low heat capacity temperature measurement errors, easier spatial deployment, and replacement of multiple angle infrared camera shooting and the continuous monitoring of surfaces that are not visually accessible.
Plate motions and deformations from geologic and geodetic data
NASA Technical Reports Server (NTRS)
Jordan, Thomas H.
1990-01-01
An analysis of geodetic data in the vicinity of the Crustal Dynamics Program (CDP) site at Vandenberg Air Force Base (VNDN) is presented. The utility of space-geodetic data in the monitoring of transient strains associated with earthquakes in tectonically active areas like California is investigated. Particular interest is in the possibility that space-geodetic methods may be able to provide critical new data on deformations precursory to large seismic events. Although earthquake precursory phenomena are not well understood, the monitoring of small strains in the vicinity of active faults is a promising technique for studying the mechanisms that nucleate large earthquakes and, ultimately, for earthquake prediction. Space-geodetic techniques are now capable of measuring baselines of tens to hundreds of kilometers with a precision of a few parts in 108. Within the next few years, it will be possible to record and analyze large-scale strain variations with this precision continuously in real time. Thus, space-geodetic techniques may become tools for earthquake prediction. In anticipation of this capability, several questions related to the temporal and spatial scales associated with subseismic deformation transients are examined.
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Continuous Turbidity Monitoring in the Indian Creek Watershed, Tazewell County, Virginia, 2006-08
Moyer, Douglas; Hyer, Kenneth
2009-01-01
Thousands of miles of natural gas pipelines are installed annually in the United States. These pipelines commonly cross streams, rivers, and other water bodies during pipeline construction. A major concern associated with pipelines crossing water bodies is increased sediment loading and the subsequent impact to the ecology of the aquatic system. Several studies have investigated the techniques used to install pipelines across surface-water bodies and their effect on downstream suspended-sediment concentrations. These studies frequently employ the evaluation of suspended-sediment or turbidity data that were collected using discrete sample-collection methods. No studies, however, have evaluated the utility of continuous turbidity monitoring for identifying real-time sediment input and providing a robust dataset for the evaluation of long-term changes in suspended-sediment concentration as it relates to a pipeline crossing. In 2006, the U.S. Geological Survey, in cooperation with East Tennessee Natural Gas and the U.S. Fish and Wildlife Service, began a study to monitor the effects of construction of the Jewell Ridge Lateral natural gas pipeline on turbidity conditions below pipeline crossings of Indian Creek and an unnamed tributary to Indian Creek, in Tazewell County, Virginia. The potential for increased sediment loading to Indian Creek is of major concern for watershed managers because Indian Creek is listed as one of Virginia's Threatened and Endangered Species Waters and contains critical habitat for two freshwater mussel species, purple bean (Villosa perpurpurea) and rough rabbitsfoot (Quadrula cylindrical strigillata). Additionally, Indian Creek contains the last known reproducing population of the tan riffleshell (Epioblasma florentina walkeri). Therefore, the objectives of the U.S. Geological Survey monitoring effort were to (1) develop a continuous turbidity monitoring network that attempted to measure real-time changes in suspended sediment (using turbidity as a surrogate) downstream from the pipeline crossings, and (2) provide continuous turbidity data that enable the development of a real-time turbidity-input warning system and assessment of long-term changes in turbidity conditions. Water-quality conditions were assessed using continuous water-quality monitors deployed upstream and downstream from the pipeline crossings in Indian Creek and the unnamed tributary. These paired upstream and downstream monitors were outfitted with turbidity, pH (for Indian Creek only), specific-conductance, and water-temperature sensors. Water-quality data were collected continuously (every 15 minutes) during three phases of the pipeline construction: pre-construction, during construction, and post-construction. Continuous turbidity data were evaluated at various time steps to determine whether the construction of the pipeline crossings had an effect on downstream suspended-sediment conditions in Indian Creek and the unnamed tributary. These continuous turbidity data were analyzed in real time with the aid of a turbidity-input warning system. A warning occurred when turbidity values downstream from the pipeline were 6 Formazin Nephelometric Units or 15 percent (depending on the observed range) greater than turbidity upstream from the pipeline crossing. Statistical analyses also were performed on monthly and phase-of-construction turbidity data to determine if the pipeline crossing served as a long-term source of sediment. Results of this intensive water-quality monitoring effort indicate that values of turbidity in Indian Creek increased significantly between the upstream and downstream water-quality monitors during the construction of the Jewell Ridge pipeline. The magnitude of the significant turbidity increase, however, was small (less than 2 Formazin Nephelometric Units). Patterns in the continuous turbidity data indicate that the actual pipeline crossing of Indian Creek had little influence of downstream water quality; co
Non-contact arrhythmia assessment in natural settings: a step toward preventive cardiac care
NASA Astrophysics Data System (ADS)
Amelard, Robert; Hughson, Richard L.; Clausi, David A.; Wong, Alexander
2017-02-01
Cardiovascular disease is a major contributor to US morbidity. Taking preventive action can greatly reduce or eliminate the impact on quality of life. However, many issues often go undetected until the patient presents a physical symptom. Non-intrusive continuous cardiovascular monitoring systems may make detecting and monitoring abnormalities earlier feasible. One candidate system is photoplethysmographic imaging (PPGI), which is able to assess arterial blood pulse characteristics in one or multiple individuals remotely from a distance. In this case study, we showed that PPGI can be used to detect cardiac arrhythmia that would otherwise require contact-based monitoring techniques. Using a novel system, coded hemodynamic imaging (CHI), strong temporal blood pulse waveform signals were extracted at a distance of 1.5 m from the participant using 850-1000 nm diffuse illumination for deep tissue penetration. Data were recorded at a sampling rate of 60 Hz, providing a temporal resolution of 17 ms. The strong fidelity of the signal allowed for both temporal and spectral assessment of abnormal blood pulse waveforms, ultimately to detect the onset of abnormal cardiac events. Data from a participant with arrhythmia was analyzed and compared against normal blood pulse waveform data to validate CHI's ability to assess cardiac arrhythmia. Results indicate that CHI can be used as a non-intrusive continuous cardiac monitoring system.
Kim, Keewon; Cho, Charles; Bang, Moon-Suk; Shin, Hyung-Ik; Phi, Ji-Hoon; Kim, Seung-Ki
2018-05-01
Intraoperative monitoring (IOM) utilizes electrophysiological techniques as a surrogate test and evaluation of nervous function while a patient is under general anesthesia. They are increasingly used for procedures, both surgical and endovascular, to avoid injury during an operation, examine neurological tissue to guide the surgery, or to test electrophysiological function to allow for more complete resection or corrections. The application of IOM during pediatric brain tumor resections encompasses a unique set of technical issues. First, obtaining stable and reliable responses in children of different ages requires detailed understanding of normal ageadjusted brain-spine development. Neurophysiology, anatomy, and anthropometry of children are different from those of adults. Second, monitoring of the brain may include risk to eloquent functions and cranial nerve functions that are difficult with the usual neurophysiological techniques. Third, interpretation of signal change requires unique sets of normative values specific for children of that age. Fourth, tumor resection involves multiple considerations including defining tumor type, size, location, pathophysiology that might require maximal removal of lesion or minimal intervention. IOM techniques can be divided into monitoring and mapping. Mapping involves identification of specific neural structures to avoid or minimize injury. Monitoring is continuous acquisition of neural signals to determine the integrity of the full longitudinal path of the neural system of interest. Motor evoked potentials and somatosensory evoked potentials are representative methodologies for monitoring. Free-running electromyography is also used to monitor irritation or damage to the motor nerves in the lower motor neuron level : cranial nerves, roots, and peripheral nerves. For the surgery of infratentorial tumors, in addition to free-running electromyography of the bulbar muscles, brainstem auditory evoked potentials or corticobulbar motor evoked potentials could be combined to prevent injury of the cranial nerves or nucleus. IOM for cerebral tumors can adopt direct cortical stimulation or direct subcortical stimulation to map the corticospinal pathways in the vicinity of lesion. IOM is a diagnostic as well as interventional tool for neurosurgery. To prove clinical evidence of it is not simple. Randomized controlled prospective studies may not be possible due to ethical reasons. However, prospective longitudinal studies confirming prognostic value of IOM are available. Furthermore, oncological outcome has also been shown to be superior in some brain tumors, with IOM. New methodologies of IOM are being developed and clinically applied. This review establishes a composite view of techniques used today, noting differences between adult and pediatric monitoring.
Sensing and Timekeeping Using A Light Trapping
2017-06-01
bioassays, condensed matter physics, mate- rial science, biothermometry, bulk magnetometry for surveying, and hyper -polarized media for NMR. 1.3.2...obtained under continuous-wave (CW) microwave field excitation when a 3 mm diameter loop of 200 µm-diameter wire is placed 5 mm above the LTDW. An...frequency-locking technique was also developed to monitor both resonances simultaneously. A closed- loop system that locks to the center frequency of
1987-12-01
assessment of data collection techniques *quantification of temporal and spatial patterns of variables *assessment of end point variability...nutrient variables are also being examined as covarlates. Development of a model to test for differences in growth patterns is continuing. At each of...condition. These variables are recorded at the end of each growing season. For evaluation of height growth patterns , a subsample of 100 seedlings per
Riboni, Daniele; Bettini, Claudio; Civitarese, Gabriele; Janjua, Zaffar Haider; Helaoui, Rim
2016-02-01
In an ageing world population more citizens are at risk of cognitive impairment, with negative consequences on their ability of independent living, quality of life and sustainability of healthcare systems. Cognitive neuroscience researchers have identified behavioral anomalies that are significant indicators of cognitive decline. A general goal is the design of innovative methods and tools for continuously monitoring the functional abilities of the seniors at risk and reporting the behavioral anomalies to the clinicians. SmartFABER is a pervasive system targeting this objective. A non-intrusive sensor network continuously acquires data about the interaction of the senior with the home environment during daily activities. A novel hybrid statistical and knowledge-based technique is used to analyses this data and detect the behavioral anomalies, whose history is presented through a dashboard to the clinicians. Differently from related works, SmartFABER can detect abnormal behaviors at a fine-grained level. We have fully implemented the system and evaluated it using real datasets, partly generated by performing activities in a smart home laboratory, and partly acquired during several months of monitoring of the instrumented home of a senior diagnosed with MCI. Experimental results, including comparisons with other activity recognition techniques, show the effectiveness of SmartFABER in terms of recognition rates. Copyright © 2016 Elsevier B.V. All rights reserved.
Chiral Process Monitoring Using Fourier Transform Microwave Spectroscopy
NASA Astrophysics Data System (ADS)
Neill, Justin L.; Muckle, Matt; Pate, Brooks
2017-06-01
We present the application of Fourier transform microwave (FTMW) spectroscopy in monitoring the chiral purity of components in a reaction mixture. This is of particular interest due to the increasing use of continuous pharmaceutical manufacturing processes, in which a number of attributes (including the chiral purity of the product) can change on short time scales. Therefore, new techniques that can accomplish this measurement rapidly are desired. The excellent specificity of FTMW spectroscopy, coupled with newly developed techniques for measuring enantiomeric excess in a mixture, have motivated this work. In collaboration with B. Frank Gupton (Virginia Commonwealth University), we are testing this application first with the synthesis of artemisinin. Artemisinin, a common drug for malaria treatment, is of high global health interest and subject to supply shortages, and therefore a strong candidate for continuous manufacturing. It also has moderately high molecular weight (282 amu) and seven chiral centers, making it a good candidate to test the capabilities of FTMW spectroscopy. Using a miniature cavity-enhanced FTMW spectrometer design, we aim to demonstrate selective component quantification in the reaction mixture. Future work that will be needed to fully realize this application will be discussed. R.D. Suenram, J.U. Grabow, A.Zuban, and I.Leonov, Rev. Sci. Instrum. 70, 2127 (1999).
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...
Integrated High Resolution Monitoring of Mediterranean vegetation
NASA Astrophysics Data System (ADS)
Cesaraccio, Carla; Piga, Alessandra; Ventura, Andrea; Arca, Angelo; Duce, Pierpaolo; Mereu, Simone
2017-04-01
The study of the vegetation features in a complex and highly vulnerable ecosystems, such as Mediterranean maquis, leads to the need of using continuous monitoring systems at high spatial and temporal resolution, for a better interpretation of the mechanisms of phenological and eco-physiological processes. Near-surface remote sensing techniques are used to quantify, at high temporal resolution, and with a certain degree of spatial integration, the seasonal variations of the surface optical and radiometric properties. In recent decades, the design and implementation of global monitoring networks involved the use of non-destructive and/or cheaper approaches such as (i) continuous surface fluxes measurement stations, (ii) phenological observation networks, and (iii) measurement of temporal and spatial variations of the vegetation spectral properties. In this work preliminary results from the ECO-SCALE (Integrated High Resolution Monitoring of Mediterranean vegetation) project are reported. The project was manly aimed to develop an integrated system for environmental monitoring based on digital photography, hyperspectral radiometry , and micrometeorological techniques during three years of experimentation (2013-2016) in a Mediterranean site of Italy (Capo Caccia, Alghero). The main results concerned the analysis of chromatic coordinates indices from digital images, to characterized the phenological patterns for typical shrubland species, determining start and duration of the growing season, and the physiological status in relation to different environmental drought conditions; then the seasonal patterns of canopy phenology, was compared to NEE (Net Ecosystem Exchange) patterns, showing similarities. However, maximum values of NEE and ER (Ecosystem respiration), and short term variation, seemed mainly tuned by inter annual pattern of meteorological variables, in particular of temperature recorded in the months preceding the vegetation green-up. Finally, green signals (gcc, ExG) from digital images was also in according to the spectral signature (NDVI) obtained for single species (in particular for Juniperus phoenicea and Pistacia lentiscus). The integrated system developed during this project can provide continuous and high-resolution data, providing a valuable support for both ecological and environmental studies in particular for the analysis of phenological plants responses to environmental and climate changes, and the validation of eco-physiological models, and supporting research on climate change adaptations. This research was funded by the Regional Administration of Sardinia, RAS, L.R. 7/2007 "Scientific Research and Technological Innovation in Sardinia ".
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission...
National protocol framework for the inventory and monitoring of bees
Droege, Sam; Engler, Joseph D.; Sellers, Elizabeth A.; Lee O'Brien,
2016-01-01
This national protocol framework is a standardized tool for the inventory and monitoring of the approximately 4,200 species of native and non-native bee species that may be found within the National Wildlife Refuge System (NWRS) administered by the U.S. Fish and Wildlife Service (USFWS). However, this protocol framework may also be used by other organizations and individuals to monitor bees in any given habitat or location. Our goal is to provide USFWS stations within the NWRS (NWRS stations are land units managed by the USFWS such as national wildlife refuges, national fish hatcheries, wetland management districts, conservation areas, leased lands, etc.) with techniques for developing an initial baseline inventory of what bee species are present on their lands and to provide an inexpensive, simple technique for monitoring bees continuously and for monitoring and evaluating long-term population trends and management impacts. The latter long-term monitoring technique requires a minimal time burden for the individual station, yet can provide a good statistical sample of changing populations that can be investigated at the station, regional, and national levels within the USFWS’ jurisdiction, and compared to other sites within the United States and Canada. This protocol framework was developed in cooperation with the United States Geological Survey (USGS), the USFWS, and a worldwide network of bee researchers who have investigated the techniques and methods for capturing bees and tracking population changes. The protocol framework evolved from field and lab-based investigations at the USGS Bee Inventory and Monitoring Laboratory at the Patuxent Wildlife Research Center in Beltsville, Maryland starting in 2002 and was refined by a large number of USFWS, academic, and state groups. It includes a Protocol Introduction and a set of 8 Standard Operating Procedures or SOPs and adheres to national standards of protocol content and organization. The Protocol Narrative describes the history and need for the protocol framework and summarizes the basic elements of objectives, sampling design, field methods, training, data management, analysis, and reporting. The SOPs provide more detail and specific instructions for implementing the protocol framework. A central database, for managing all the resulting data is under development. We welcome use of this protocol framework by our partners, as appropriate for their bee inventory and monitoring objectives.
Applicability of the PEMS technique for simplified NO X monitoring on board ships
NASA Astrophysics Data System (ADS)
Cooper, D. A.; Ekström, M.
The performance of a predictive emission monitoring system (PEMS) as a technique for NO x monitoring on medium speed marine diesel engines has been evaluated for 16 similar engines on four different ships. The PEMS function tested measured O 2 concentration in the exhaust gas, engine load, combustion air temperature and humidity, and barometric pressure to calculate the NO x concentration. Emission measurements were carried out by means of a conventional continuous emission monitoring system (CEMS) and the measured NO x concentrations were compared with those calculated by the PEMS function. For 11 of the 16 engines, the average error between measured and calculated NO x concentration was <10% of the calibration range (1725 ppm). In addition, 10 of the engines displayed correlation coefficients between measured and calculated NO x as 0.90 or higher. For two of the ships, the predicted NO x concentrations from all engines on board gave good agreement with those measured (2.6-4.7% and 2.6-8.0% average error). In other cases however, the performance of the PEMS function was poor e.g. the four engines of ship D showed average errors of 10.3-17.7%. Although similar engine models, fuel and load characteristics were compared in the tests, the specific NO x emissions at steady-state loads used varied from 12.6 up to 15.8 g k -1Wh corr. Although a single PEMS function may prove universal and adequate for calculating NO x emissions from similar engines on board the same ship, an engine specific PEMS function is recommended. The form of the PEMS function, i.e. using exhaust O 2 and engine load as inputs, is however likely to be applicable to most propeller-law diesel engines. Bearing in mind the performance criteria for using PEMS at land-based installations, the results from this study are promising. Viewed as a single data set of 56 h with 16 separate engine comparisons between CEMS and PEMS, the data set shows a relative accuracy of 14.5% i.e. within the 20% requirement of the US Environmental Protection Agency. In light of the increased interest and international guidelines for continuous NO x monitoring on board ships, the PEMS technique can offer a simple but cost-effective option.
Tracheobronchomegaly associated tracheomalacia: analysis by sleep study.
Sundaram, P; Joshi, J M
2004-01-01
Tracheobronchomegaly (TBM) occasionally may progress to extensive tracheomalacia which leads to respiratory failure. Spirometry, dynamic expiratory multidetector computed tomography (CT), bronchoscopy are used to diagnose patients of suspected tracheobronchomalacia. We used the technique of night-time monitoring of respiratory variables to show the presence of respiratory abnormalities during sleep and which was corrected by applying nasal continuous positive airway pressure (CPAP). The study showed the presence of both apnoea and hypopnoeas, which were obstructive in nature with an apnoea-hypopnoea index (AHI) of 11, no snoring and associated oxygen desaturation of 75 per cent. A second overnight study with nasal continuous positive airway pressure at a critical pressure of 8 cm, the AHI decreased to 3 along with no drop in oxygen saturation. This non-invasive technique should be considered as a diagnostic tool in tracheobronchomalacia and to know the outcome of CPAP, surgical or stent therapy in this condition.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 60.1270 Section 60.1270 Protection of Environment... Continuous Emission Monitoring § 60.1270 What is required for my continuous opacity monitoring system and how... system. (b) Install, evaluate, and operate each continuous opacity monitoring system according to § 60.13...
Acoustic Emission Beamforming for Detection and Localization of Damage
NASA Astrophysics Data System (ADS)
Rivey, Joshua Callen
The aerospace industry is a constantly evolving field with corporate manufacturers continually utilizing innovative processes and materials. These materials include advanced metallics and composite systems. The exploration and implementation of new materials and structures has prompted the development of numerous structural health monitoring and nondestructive evaluation techniques for quality assurance purposes and pre- and in-service damage detection. Exploitation of acoustic emission sensors coupled with a beamforming technique provides the potential for creating an effective non-contact and non-invasive monitoring capability for assessing structural integrity. This investigation used an acoustic emission detection device that employs helical arrays of MEMS-based microphones around a high-definition optical camera to provide real-time non-contact monitoring of inspection specimens during testing. The study assessed the feasibility of the sound camera for use in structural health monitoring of composite specimens during tensile testing for detecting onset of damage in addition to nondestructive evaluation of aluminum inspection plates for visualizing stress wave propagation in structures. During composite material monitoring, the sound camera was able to accurately identify the onset and location of damage resulting from large amplitude acoustic feedback mechanisms such as fiber breakage. Damage resulting from smaller acoustic feedback events such as matrix failure was detected but not localized to the degree of accuracy of larger feedback events. Findings suggest that beamforming technology can provide effective non-contact and non-invasive inspection of composite materials, characterizing the onset and the location of damage in an efficient manner. With regards to the nondestructive evaluation of metallic plates, this remote sensing system allows us to record wave propagation events in situ via a single-shot measurement. This is a significant improvement over the conventional wave propagation tracking technique based on laser doppler vibrometry that requires synchronization of data acquired from numerous excitations and measurements. The proposed technique can be used to characterize and localize damage by detecting the scattering, attenuation, and reflections of stress waves resulting from damage and defects. These studies lend credence to the potential development of new SHM/NDE techniques based on acoustic emission beamforming for characterizing a wide spectrum of damage modes in next-generation materials and structures without the need for mounted contact sensors.
GNSS Monitoring of Deformation within heavy civil infrastructure
NASA Astrophysics Data System (ADS)
Montillet, Jean-Philippe; Melbourne, Timothy; Szeliga, Walter; Schrock, Gavin
2015-04-01
The steady increase in precision simultaneous with the decreasing of continuous GPS monitoring has enabled the deployment of receivers for a host of new activities. Here we discuss the precision obtained from several multi-station installations operated over a five-year period on several heavy civil-engineered structures, including two earthen-fill dams and subsiding highway overpass damaged by seismic shaking. In the past 5 years, the Cascadia Hazards Institute (Pacific Northwest Geodetic Array) at Central Washington University together with the Washington department of public utilities (Land Survey) have been monitoring several structures around Seattle area including two dams (Howard Hansen and Tolt). One aim of this study is to test the use of continuous GNSS in order to detect any deformations due to rapid pool level rises or to monitor the safety of a structure when an Earthquake strikes it. In this study, data is processed using Real Time Kinematic GPS with short baseline (d < 500 m) and GPS daily position (PPP). However, multipath is the most limiting factor on accuracy for very precise positioning applications with GPS. It is very often present indoors and outdoors, especially in narrow valleys with a limited view of the sky. As a result, multipath can amount to an error of a few centimetres. Unfortunately, the accuracy requirements of precision deformation monitoring are generally at the sub centimetre level, which is presently a big challenge on an epoch-by-epoch basis with regular, carrier phase techniques. Thus, it needs to be properly mitigated. In this study, several stations are set up on the dams (4 stations on the Tolt reservoir and 10 stations on the Howard Hansen dam), and spatial filtering can then be used to mitigate multipath. In addition, several signal processing techniques are also investigated (i.e. Empirical mode decomposition, sidereal filtering, adaptive filtering). RTK GPS should allow to monitor rapid deformations, whereas GPS daily position is used to detect long-term deformations such as the pool level rises due to the melting of ice cap on surrounding mountains. Note that RTK measurements are processed with the MIT software TRACK and the GPS daily positions estimated with GAMIT-GLOBK.
Laser techniques in conservation in Europe
NASA Astrophysics Data System (ADS)
Salimbeni, Renzo
2005-06-01
The state of the art of laser techniques employed in conservation of cultural heritage is continuously growing in Europe. Many research projects organised at the European level have contributed to this achievement, being complementary to the development carried out at national level. The COST Action G7 is playing its unique role since the year 2000 in promoting the experimentation, comparing the experiences and disseminating best practices. This role has been particularly effective for monitoring of the results of many short-term research projects completed along the G7 Action lifetime. After that several laser cleaning techniques have been followed and evaluated it appears now clear an evolution of the systems, a specialization of the cleaning task, the achievement of side-effect free procedures. The validation of these advanced cleaning techniques has been extensive and diffused in many European countries, especially for stone and metals. Laser-based diagnostics have also specialised their tasks toward material analysis, defects detection and multidimensional documentation. Laser and optical methods successfully monitor deterioration effects. In many European countries interdisciplinary networks are managing the experimentation of these techniques giving them a sound scientific approach, but also a technology transfer to end-users. So doing the appreciation for these techniques is growing in all the conservation institutions involved at national level, disseminating a positive evaluation about the benefits provided by laser techniques in conservation. Several laser systems became products for the activity of professional restorers and their increasing sales demonstrate a growing utilisation throughout all Europe.
Facility design consideration for continuous mix production of class 1.3 propellant
NASA Technical Reports Server (NTRS)
Williamson, K. L.; Schirk, P. G.
1994-01-01
In November of 1989, NASA awarded the Advanced Solid Rocket Motor (ASRM) contract to Lockheed Missiles and Space Company (LMSC) for production of advanced solid rocket motors using the continuous mix process. Aerojet ASRM division (AAD) was selected as the facility operator and RUST International Corporation provided the engineering, procurement, and construction management services. The continuous mix process mandates that the mix and cast facilities be 'close-coupled' along with the premix facilities, creating unique and challenging requirements for the facility designer. The classical approach to handling energetic materials-division into manageable quantities, segregation, and isolation-was not available due to these process requirements and quantities involved. This paper provides a description of the physical facilities, the continuous mix process, and discusses the monitoring and detection techniques used to mitigate hazards and prevent an incident.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
NASA Astrophysics Data System (ADS)
Kallioras, Andreas; Tsertou, Athanasia; Foglia, Laura; Bumberger, Jan; Vienken, Thomas; Dietrich, Peter; Schüth, Christoph
2014-05-01
Artificial recharge of groundwater has an important role to play in water reuse. Treated sewage effluent can be infiltrated into the ground for recharge of aquifers. As the effluent water moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. Recharge systems for SAT can be designed as infiltration-recovery systems, where all effluent water is recovered as such from the aquifer, or after blending with native groundwater. SAT typically removes essentially all suspended solids, biochemical oxygen demand (BOD), and pathogens (viruses, bacteria, protozoa, and helminthic eggs). Concentrations of synthetic organic carbon, phosphorous, and heavy metals are greatly reduced. The pilot site of LTCP will involve the employment of infiltration basins, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. T he LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved through the development and installation of an integrated system of prototype sensors, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time Domain Reflectometry (TDR) sensors will be developed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. The above technique will offer continuous monitoring of infiltration rates and possible mechanical clogging effects. The qualitative monitoring of the unsaturated zone will be achieved through the installation of appropriate pore-water samplers within a multi-level basis, ensuring repeatability of sampling of infiltrating water of impaired quality. This study also involves the qualitative and quantitative assessment of the Lavrion multi-aquifer system through continuous monitoring of the performance of (i) the alluvial aquifer and its potential for additional water treatment as well as (ii) the effects of the SAT system for countermeasuring seawater intrusion in the area of Lavrion. Additionally, setup and calibration of numerical flow and transport models for evaluating and optimizing different operational modes of the SAT system within both saturated and unsaturated zones will be conducted. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
Downey, C L; Brown, J M; Jayne, D G; Randell, R
2018-06-01
Vital signs monitoring is used to identify deteriorating patients in hospital. The most common tool for vital signs monitoring is an early warning score, although emerging technologies allow for remote, continuous patient monitoring. A number of reviews have examined the impact of continuous monitoring on patient outcomes, but little is known about the patient experience. This study aims to discover what patients think of monitoring in hospital, with a particular emphasis on intermittent early warning scores versus remote continuous monitoring, in order to inform future implementations of continuous monitoring technology. Semi-structured interviews were undertaken with 12 surgical inpatients as part of a study testing a remote continuous monitoring device. All patients were monitored with both an early warning score and the new device. Interviews were audio-recorded, transcribed verbatim and analysed using thematic analysis. Patients can see the value in remote, continuous monitoring, particularly overnight. However, patients appreciate the face-to-face aspect of early warning score monitoring as it allows for reassurance, social interaction, and gives them further opportunity to ask questions about their medical care. Early warning score systems are widely used to facilitate detection of the deteriorating patient. Continuous monitoring technologies may provide added reassurance. However, patients value personal contact with their healthcare professionals and remote monitoring should not replace this. We suggest that remote monitoring is best introduced in a phased manner, and initially as an adjunct to usual care, with careful consideration of the patient experience throughout. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramuhalli, Pradeep; Hirt, Evelyn H.; Dib, Gerges
This project involved the development of enhanced risk monitors (ERMs) for active components in Advanced Reactor (AdvRx) designs by integrating real-time information about equipment condition with risk monitors. Health monitoring techniques in combination with predictive estimates of component failure based on condition and risk monitors can serve to indicate the risk posed by continued operation in the presence of detected degradation. This combination of predictive health monitoring based on equipment condition assessment and risk monitors can also enable optimization of maintenance scheduling with respect to the economics of plant operation. This report summarizes PNNL’s multi-year project on the development andmore » evaluation of an ERM concept for active components while highlighting FY2016 accomplishments. Specifically, this report provides a status summary of the integration and demonstration of the prototypic ERM framework with the plant supervisory control algorithms being developed at Oak Ridge National Laboratory (ORNL), and describes additional case studies conducted to assess sensitivity of the technology to different quantities. Supporting documentation on the software package to be provided to ONRL is incorporated in this report.« less
Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System
Chou, Willy; Wang, Hsing-Yu; Huang, Yan-Jun; Pan, Jeng-Shyang
2013-01-01
Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes. PMID:27170853
Pulse oximetry-derived respiratory rate in general care floor patients.
Addison, Paul S; Watson, James N; Mestek, Michael L; Ochs, James P; Uribe, Alberto A; Bergese, Sergio D
2015-02-01
Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. We report here on an algorithm designed to meet clinical needs by providing respiratory rate through a standard pulse oximeter. Finger photoplethysmograms were collected from a cohort of 63 GCF patients monitored during free breathing over a 25-min period. These were processed using a novel in-house algorithm based on continuous wavelet-transform technology within an infrastructure incorporating confidence-based averaging and logical decision-making processes. The computed oximeter respiratory rates (RRoxi) were compared to an end-tidal CO2 reference rate (RRETCO2). RRETCO2 ranged from a lowest recorded value of 4.7 breaths per minute (brpm) to a highest value of 32.0 brpm. The mean respiratory rate was 16.3 brpm with standard deviation of 4.7 brpm. Excellent agreement was found between RRoxi and RRETCO2, with a mean difference of -0.48 brpm and standard deviation of 1.77 brpm. These data demonstrate that our novel respiratory rate algorithm is a potentially viable method of monitoring respiratory rate in GCF patients. This technology provides the means to facilitate continuous monitoring of respiratory rate, coupled with arterial oxygen saturation and pulse rate, using a single non-invasive sensor in low acuity settings.
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
NASA Astrophysics Data System (ADS)
Chung, Chih-Yao; Wang, Jhih-Cheng; Chuang, Han-Sheng
2017-04-01
Successful treatments against bacterial infections depend on antimicrobial susceptibility testing (AST). However, conventional AST requires more than 24 h to obtain an outcome, thereby contributing to high patient mortality. An antibiotic therapy based on experiences is therefore necessary for saving lives and escalating the emergence of multidrug-resistant pathogens. Accordingly, a fast and effective drug screen is necessary for the appropriate administration of antibiotics. The mixed pathogenic nature of infectious diseases emphasizes the need to develop an assay system for polymicrobial infections. On this basis, we present a novel technique for simultaneous and quantitative monitoring of co-cultured microorganisms by coupling optical diffusometry with bead-based immunoassays. This simple integration simultaneously achieves a rapid AST analysis for two pathogens. Triple color particles were simultaneously recorded and subsequently analyzed by functionalizing different fluorescent color particles with dissimilar pathogen-specific antibodies. Results suggested that the effect of the antibiotic, gentamicin, on co-cultured Pseudomonas aeruginosa and Staphylococcus aureus was effectively distinguished by the proposed technique. This study revealed a multiplexed and time-saving (within 2 h) platform with a small sample volume (~0.5 μL) and a low initial bacterial count (50 CFU per droplet, ~105 CFU/mL) for continuously monitoring the growth of co-cultured microorganisms. This technique provides insights into timely therapies against polymicrobial diseases in the near future.
Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.
2018-01-01
Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0-11.2) to 10.0% (95% confidence interval 6.75-13.25) and decreased the number of severe hypoglycemic events.Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring interventions to usual care. However, the uncertainty around the ICERs was large. The net budget impact of publicly funding continuous glucose monitoring assuming a 20% annual increase in adoption of continuous glucose monitoring would range from $8.5 million in year 1 to $16.2 million in year 5.Patient engagement surrounding the topic of continuous glucose monitoring was robust. Patients perceived that these devices provided important social, emotional, and medical and safety benefits in managing type 1 diabetes, especially in children. Continuous glucose monitoring was more effective than self-monitoring of blood glucose in managing type 1 diabetes for some outcomes, such as time spent in the target glucose range and time spent outside the target glucose range (moderate certainty in this evidence). We were less certain that continuous glucose monitoring would reduce the number of severe hypoglycemic events. Compared with self-monitoring of blood glucose, the costs of continuous glucose monitoring were higher, with only small increases in health benefits. Publicly funding continuous glucose monitoring for the type 1 diabetes population in Ontario would result in additional costs to the health system over the next 5 years. Adult patients and parents of children with type 1 diabetes reported very positive experiences with continuous glucose monitoring. The high ongoing cost of continuous glucose monitoring devices was seen as the greatest barrier to their widespread use.
Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment
Vandersluis, Stacey; Kabali, Conrad; Djalalov, Sandjar; Gajic-Veljanoski, Olga; Wells, David; Holubowich, Corinne
2018-01-01
Background Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. Methods We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Results Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0–11.2) to 10.0% (95% confidence interval 6.75–13.25) and decreased the number of severe hypoglycemic events. Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring interventions to usual care. However, the uncertainty around the ICERs was large. The net budget impact of publicly funding continuous glucose monitoring assuming a 20% annual increase in adoption of continuous glucose monitoring would range from $8.5 million in year 1 to $16.2 million in year 5. Patient engagement surrounding the topic of continuous glucose monitoring was robust. Patients perceived that these devices provided important social, emotional, and medical and safety benefits in managing type 1 diabetes, especially in children. Conclusions Continuous glucose monitoring was more effective than self-monitoring of blood glucose in managing type 1 diabetes for some outcomes, such as time spent in the target glucose range and time spent outside the target glucose range (moderate certainty in this evidence). We were less certain that continuous glucose monitoring would reduce the number of severe hypoglycemic events. Compared with self-monitoring of blood glucose, the costs of continuous glucose monitoring were higher, with only small increases in health benefits. Publicly funding continuous glucose monitoring for the type 1 diabetes population in Ontario would result in additional costs to the health system over the next 5 years. Adult patients and parents of children with type 1 diabetes reported very positive experiences with continuous glucose monitoring. The high ongoing cost of continuous glucose monitoring devices was seen as the greatest barrier to their widespread use. PMID:29541282
40 CFR Table 4 to Subpart Hhhhhhh... - Applicability of the General Provisions to Part 63
Code of Federal Regulations, 2014 CFR
2014-07-01
... SSM plan for continuous monitoring systems No. § 63.8(c)(5) Continuous opacity monitoring system...) Written procedures for continuous monitoring systems Yes, except for last sentence, which refers to an SSM plan. SSM plans are not required § 63.8(e) Continuous monitoring systems performance evaluation Yes...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...
NASA Astrophysics Data System (ADS)
Sudhakar, P.; Kalavathi, P.; Ramakrishna Rao, D.; Satyanarayna, M.
2014-12-01
Industrialization can no longer sustain without internalization of the concerns of the receiving environment and land-use. Increased awareness and public pressure, coupled with regulatory instruments and bodies exert constant pressure on industries to control their emissions to a level acceptable to the receiving environment. However, when a group of industries come-up together as an industrial estate, the cumulative impacts of all the industries together often challenges the expected/desired quality of receiving environment, requiring stringent pollution control and monitoring measures. Laser remote sensing techniques provide powerful tools for environmental monitoring. These methods provide range resolved measurements of concentrations of various gaseous pollutants and suspended particulate matter (SPM) not only in the path of the beam but over the entire area. A three dimensional mapping of the pollutants and their dispersal can be estimated using the laser remote sensing methods on a continuous basis. Laser Radar (Lidar) systems are the measurements technology used in the laser remote sensing methods. Differential absorption lidar (DIAL) and Raman Lidar technologies have proved to be very useful for remote sensing of air pollutants. DIAL and Raman lidar systems can be applied for range resolved measurements of molecules like SO2, NO2, O3 Hg, CO, C2H4, H2O, CH4, hydrocarbons etc. in real time on a continuous basis. This paper describes the design details of the DAIL and Raman lidar techniques for measurement of various hazardous air pollutants which are being released into the atmosphere by the chemical industries operating in the Bachupally industrial Estate area at Hyderabad, India. The relative merits of the two techniques have been studied and the minimum concentration of pollutants that can be measured using these systems are presented. A dispersion model of the air pollutants in the selected chemical industrial estates at Hyderabad has been developed.
He, Yabai; Kan, Ruifeng; Englich, Florian V; Liu, Wenqing; Orr, Brian J
2010-09-13
The greenhouse-gas molecules CO(2), CH(4), and H(2)O are detected in air within a few ms by a novel cavity-ringdown laser-absorption spectroscopy technique using a rapidly swept optical cavity and multi-wavelength coherent radiation from a set of pre-tuned near-infrared diode lasers. The performance of various types of tunable diode laser, on which this technique depends, is evaluated. Our instrument is both sensitive and compact, as needed for reliable environmental monitoring with high absolute accuracy to detect trace concentrations of greenhouse gases in outdoor air.
Monitoring Earth Surface Dynamics With Optical Imagery
NASA Astrophysics Data System (ADS)
Leprince, Sébastien; Berthier, Etienne; Ayoub, François; Delacourt, Christophe; Avouac, Jean-Philippe
2008-01-01
The increasing availability of high-quality optical satellite images should allow, in principle, continuous monitoring of Earth's surface changes due to geologic processes, climate change, or anthropic activity. For instance, sequential optical images have been used to measure displacements at Earth's surface due to coseismic ground deformation [e.g., Van Puymbroeck et al., 2000], ice flow [Scambos et al., 1992; Berthier et al., 2005], sand dune migration [Crippen, 1992], and landslides [Kääb, 2002; Delacourt et al., 2004]. Surface changes related to agriculture, deforestation, urbanization, and erosion-which do not involve ground displacement-might also be monitored, provided that the images can be registered with sufficient accuracy. Although the approach is simple in principle, its use is still limited, mainly because of geometric distortion of the images induced by the imaging system, biased correlation techniques, and implementation difficulties.
Optical detection of blade flutter. [in YF-100 turbofan engine
NASA Technical Reports Server (NTRS)
Nieberding, W. C.; Pollack, J. L.
1977-01-01
The paper examines the capabilities of photoelectric scanning (PES) and stroboscopic imagery (SI) as optical monitoring tools for detection of the onset of flutter in the fan blades of an aircraft gas turbine engine. Both optical techniques give visual data in real time as well as video-tape records. PES is shown to be an ideal flutter monitor, since a single cathode ray tube displays the behavior of all the blades in a stage simultaneously. Operation of the SI system continuously while searching for a flutter condition imposes severe demands on the flash tube and affects its reliability, thus limiting its use as a flutter monitor. A better method of operation is to search for flutter with the PES and limit the use of SI to those times when the PES indicates interesting blade activity.
Assessment of the Impact of the California Water Project in the West Side of the San Joaquin Valley
NASA Technical Reports Server (NTRS)
Estes, J. E.; Kuhn, M.; Golomb, B.; Senger, L. W.; Wester, L.; Fortune, P.; Viellenave, J.
1971-01-01
The ability of remote sensing techniques to effectively monitor, on a continuing basis, the impact of a change in the water supply of an arid area is considered. Research involves the collection of a substantial body of information relative to both physical and biological phenomena or systems operative within the study area by concentrating on the accumulation of library materials, and field data.
ENDOSCOPIC DIAGNOSIS AND THERAPY IN GASTRO-ESOPAGEAL VARICEAL BLEEDING
Sanyal, Arun J.
2016-01-01
Gastroesophageal variceal hemorrhage is a medical emergency with high morbidity and mortality. Endoscopic therapy is the mainstay of management of bleeding varices. It requires attention to technique and the appropriate choice of therapy for a given patient at a given point in time. Subjects must be monitored continuously after initiation of therapy for control of bleeding and second line definitive therapies introduced quickly if endoscopic and pharmacologic treatment fails. PMID:26142034
Application of Non-destructive Methods of Stress-strain State at Hazardous Production Facilities
NASA Astrophysics Data System (ADS)
Shram, V.; Kravtsova, Ye; Selsky, A.; Bezborodov, Yu; Lysyannikova, N.; Lysyannikov, A.
2016-06-01
The paper deals with the sources of accidents in distillation columns, on the basis of which the most dangerous defects are detected. The analysis of the currently existing methods of non-destructive testing of the stress-strain state is performed. It is proposed to apply strain and acoustic emission techniques to continuously monitor dangerous objects, which helps prevent the possibility of accidents, as well as reduce the work.
Kubisch, Rebekka; Bohrn, Ulrich; Fleischer, Maximilian; Stütz, Evamaria
2012-01-01
Pollution of drinking water sources represents a continuously emerging problem in global environmental protection. Novel techniques for real-time monitoring of water quality, capable of the detection of unanticipated toxic and bioactive substances, are urgently needed. In this study, the applicability of a cell-based sensor system using selected eukaryotic cell lines for the detection of aquatic pollutants is shown. Readout parameters of the cells were the acidification (metabolism), oxygen consumption (respiration) and impedance (morphology) of the cells. A variety of potential cytotoxic classes of substances (heavy metals, pharmaceuticals, neurotoxins, waste water) was tested with monolayers of L6 cells (rat myoblasts). The cytotoxicity or cellular effects induced by inorganic ions (Ni2+ and Cu2+) can be detected with the metabolic parameters acidification and respiration down to 0.5 mg/L, whereas the detection limit for other substances like nicotine and acetaminophen are rather high, in the range of 0.1 mg/L and 100 mg/L. In a close to application model a real waste water sample shows detectable signals, indicating the existence of cytotoxic substances. The results support the paradigm change from single substance detection to the monitoring of overall toxicity. PMID:22737014
Kubisch, Rebekka; Bohrn, Ulrich; Fleischer, Maximilian; Stütz, Evamaria
2012-01-01
Pollution of drinking water sources represents a continuously emerging problem in global environmental protection. Novel techniques for real-time monitoring of water quality, capable of the detection of unanticipated toxic and bioactive substances, are urgently needed. In this study, the applicability of a cell-based sensor system using selected eukaryotic cell lines for the detection of aquatic pollutants is shown. Readout parameters of the cells were the acidification (metabolism), oxygen consumption (respiration) and impedance (morphology) of the cells. A variety of potential cytotoxic classes of substances (heavy metals, pharmaceuticals, neurotoxins, waste water) was tested with monolayers of L6 cells (rat myoblasts). The cytotoxicity or cellular effects induced by inorganic ions (Ni(2+) and Cu(2+)) can be detected with the metabolic parameters acidification and respiration down to 0.5 mg/L, whereas the detection limit for other substances like nicotine and acetaminophen are rather high, in the range of 0.1 mg/L and 100 mg/L. In a close to application model a real waste water sample shows detectable signals, indicating the existence of cytotoxic substances. The results support the paradigm change from single substance detection to the monitoring of overall toxicity.
Manufacturing of Wearable Sensors for Human Health and Performance Monitoring
NASA Astrophysics Data System (ADS)
Alizadeh, Azar
2015-03-01
Continuous monitoring of physiological and biological parameters is expected to improve performance and medical outcomes by assessing overall health status and alerting for life-saving interventions. Continuous monitoring of these parameters requires wearable devices with an appropriate form factor (lightweight, comfortable, low energy consuming and even single-use) to avoid disrupting daily activities thus ensuring operation relevance and user acceptance. Many previous efforts to implement remote and wearable sensors have suffered from high cost and poor performance, as well as low clinical and end-use acceptance. New manufacturing and system level design approaches are needed to make the performance and clinical benefits of these sensors possible while satisfying challenging economic, regulatory, clinical, and user-acceptance criteria. In this talk we will review several recent design and manufacturing efforts aimed at designing and building prototype wearable sensors. We will discuss unique opportunities and challenges provided by additive manufacturing, including 3D printing, to drive innovation through new designs, faster prototyping and manufacturing, distributed networks, and new ecosystems. We will also show alternative hybrid self-assembly based integration techniques for low cost large scale manufacturing of single use wearable devices. Coauthors: Prabhjot Singh and Jeffrey Ashe.
Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom
2005-08-01
Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.
NASA Astrophysics Data System (ADS)
Crockett, R. G. M.; Gillmore, G. K.
2009-04-01
During the second half of 2002, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in Northampton, in the (English) East Midlands. This period included the Dudley earthquake (22/09/2002) which was widely noticed by members of the public in the Northampton area. Also, at various periods during 2008 the Group has operated another pair of continuous hourly-sampling radon detectors similar distances apart in Northampton. One such period included the Market Rasen earthquake (27/02/2008) which was also widely noticed by members of the public in the Northampton area. During each period of monitoring, two time-series of radon readings were obtained, one from each detector. These have been analysed for evidence of simultaneous similar anomalies: the premise being that big disturbances occurring at big distances (in relation to the detector separation) should produce simultaneous similar anomalies but that simultaneous anomalies occurring by chance will be dissimilar. As previously reported, cross-correlating the two 2002 time-series over periods of 1-30 days duration, rolled forwards through the time-series at one-hour intervals produced two periods of significant correlation, i.e. two periods of simultaneous similar behaviour in the radon concentrations. One of these periods corresponded in time to the Dudley earthquake, the other corresponded in time to a smaller earthquake which occurred in the English Channel (26/08/2002). We here report subsequent investigation of the 2002 time-series and the 2008 time-series using spectral-decomposition techniques. These techniques have revealed additional simultaneous similar behaviour in the two radon concentrations, not revealed by the rolling correlation on the raw data. These correspond in time to the Manchester earthquake swarm of October 2002 and the Market Rasen earthquake of February 2008. The spectral-decomposition techniques effectively ‘de-noise' the data, and also remove lower-frequency variations (e.g. tidal variations), revealing the simultaneous similarities. Whilst this is very much work in progress, there is the potential that such techniques enhance the possibility that simultaneous real-time monitoring of radon levels - for short-term simultaneous anomalies - at several locations in earthquake areas might provide the core of an earthquake prediction method. Keywords: Radon; earthquakes; time series; cross-correlation; spectral-decomposition; real-time simultaneous monitoring.
Remotely Characterizing the Topographic and Thermal Evolution of Kīlauea's Lava Flow Field
NASA Astrophysics Data System (ADS)
Rumpf, M. E.; Vaughan, R. G.; Poland, M. P.
2017-12-01
New technologies in satellite data acquisition and the continuous development of analysis software capabilities are greatly improving the ability of scientists to monitor volcanoes in near-real-time. Satellite-based thermal infrared (TIR) data are used to monitor and analyze new and ongoing volcanic activity by identifying and quantifying surface thermal characteristics and lava flow discharge rates. Improved detector sensitivities provide unprecedented spatial detail in visible to shortwave infrared (VSWIR) satellite imagery. The acquisition of stereo and tri-stereo visible imagery, as well as SAR, by an increasing number of satellite systems enables the creation of digital elevation models (DEMs) at higher temporal frequencies and resolutions than in the past. Free, user-friendly software programs, such as NASA's Ames Stereo Pipeline and Google Earth Engine, ease the accessibility and usability of satellite data to users unfamiliar with traditional analysis techniques. An effective and efficient integration of these technologies can be utilized towards volcano monitoring.Here, we use the active lava flows from the East Rift Zone vents of Kīlauea Volcano, Hawai`i as a testing ground for developing new techniques in multi-sensor volcano remote sensing. We use DEMs generated from stereo and tri-stereo images captured by the WorldView3 and Pleiades satellite systems to assess topographic changes over time at the active flow fields. Time-series data of lava flow area, thickness, and discharge rate developed from thermal emission measurements collected by ASTER, Landsat 8, and WorldView3 are compared to satellite-detected topographic changes and to ground observations of flow development to identify behavioral patterns and to monitor flow field evolution. We explore methods of combining these visual and TIR data sets collected by multiple satellite systems with a variety of resolutions and repeat times. Our ultimate goal is to develop integrative tools for near-real-time volcano monitoring. In addition, we recommend improvements to future satellite mission capabilities (e.g., repeat times, resolutions) to improve lava flow monitoring techniques.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 60.1760 Section 60.1760 Protection of Environment... continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each continuous opacity...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...
Update on Fetal Monitoring: Overview of Approaches and Management of Category II Tracings.
Raghuraman, Nandini; Cahill, Alison G
2017-12-01
Electronic fetal monitoring (EFM) is widely used to assess fetal status in labor. Use of intrapartum continuous EFM is associated with a lower risk of neonatal seizures but a higher risk of cesarean or operative delivery. Category II fetal heart tracings (FHTs) are indeterminate in their ability to predict fetal acidemia. Certain patterns of decelerations and variability within this category may be predictive of neonatal morbidity. Adjunct tests of fetal well-being can be used during labor to further triage patients. Intrauterine resuscitation techniques should target the suspected etiology of intrapartum fetal hypoxia. Clinical factors play a role in the interpretation of EFM. Copyright © 2017 Elsevier Inc. All rights reserved.
Spatially-Aware Temporal Anomaly Mapping of Gamma Spectra
NASA Astrophysics Data System (ADS)
Reinhart, Alex; Athey, Alex; Biegalski, Steven
2014-06-01
For security, environmental, and regulatory purposes it is useful to continuously monitor wide areas for unexpected changes in radioactivity. We report on a temporal anomaly detection algorithm which uses mobile detectors to build a spatial map of background spectra, allowing sensitive detection of any anomalies through many days or months of monitoring. We adapt previously-developed anomaly detection methods, which compare spectral shape rather than count rate, to function with limited background data, allowing sensitive detection of small changes in spectral shape from day to day. To demonstrate this technique we collected daily observations over the period of six weeks on a 0.33 square mile research campus and performed source injection simulations.
Utilization of Envisat/ers SAR Data Over the Jharia Coalfield, India for Subsidence Monitoring
NASA Astrophysics Data System (ADS)
Srivastava, Vinay Kumar
2012-07-01
Extended abstract Jharia coalfield the prime coking coal-producing belt in India, started commercial production in 1894. Mining in Jharia coalfield (JCF) is in form of both opencast and underground mining. The area is affected by various environmental hazards such as, coal fire, subsidence, land degradation and toxic gas emissions. Currently, coal fire and subsidence are the major problems in the coalfield and causes continuous changes in topography. Monitoring of such dynamic topographic changes in a hazard-prone mining belt is a critical input for land environmental management. Such temporal topographic changes over span of the time and even short term mining activity within a year could be done from Digital Elevation Model (DEM) generated using various space-borne techniques.. Among all techniques available for generating DEM, SAR Interferometry technique has been successful and effective which offers high resolution spatial detail to a level of few cm. DEM obtained from processing of SAR Interferometry (InSAR) technique using ERS SAR data of April 12 and 13, 1995 provides high spatial resolution images which is useful for monitoring and measuring dynamic changes in land topography. Several workers have successfully InSAR this technique for mapping and monitoring of changes in land surface due to various causes. Using ERS tandem data sets of 16 and 17 May 1996 passes, DInSAR map over the Jharia coal field has been obtained from the interferogram generated by integrating information from ground control points and precise high coherence orbital parameters. Further, using ENVISAT/ ASAR data of June 5 and 6, 2007 and integrating GPS measurements at 4 ground points where corner reflectors were preinstalled for getting bright spots on images and using orbital parameters, a slant range corrected image over the study area has been obtained. shows the plot of differential phases along a particular profile l over a subsidence region in Jharia coal field and the corresponding correlation coefficients. . Further an attempt has been made to delineate subsidence area in Jharia coal field using SAR Interoferometry technique..
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...
Large Scale Application of Vibration Sensors for Fan Monitoring at Commercial Layer Hen Houses
Chen, Yan; Ni, Ji-Qin; Diehl, Claude A.; Heber, Albert J.; Bogan, Bill W.; Chai, Li-Long
2010-01-01
Continuously monitoring the operation of each individual fan can significantly improve the measurement quality of aerial pollutant emissions from animal buildings that have a large number of fans. To monitor the fan operation by detecting the fan vibration is a relatively new technique. A low-cost electronic vibration sensor was developed and commercialized. However, its large scale application has not yet been evaluated. This paper presents long-term performance results of this vibration sensor at two large commercial layer houses. Vibration sensors were installed on 164 fans of 130 cm diameter to continuously monitor the fan on/off status for two years. The performance of the vibration sensors was compared with fan rotational speed (FRS) sensors. The vibration sensors exhibited quick response and high sensitivity to fan operations and therefore satisfied the general requirements of air quality research. The study proved that detecting fan vibration was an effective method to monitor the on/off status of a large number of single-speed fans. The vibration sensor itself was $2 more expensive than a magnetic proximity FRS sensor but the overall cost including installation and data acquisition hardware was $77 less expensive than the FRS sensor. A total of nine vibration sensors failed during the study and the failure rate was related to the batches of product. A few sensors also exhibited unsteady sensitivity. As a new product, the quality of the sensor should be improved to make it more reliable and acceptable. PMID:22163544
Loeffert, Sophie Tiphaine; Melloul, Elise; Dananché, Cédric; Hénaff, Laetitia; Bénet, Thomas; Cassier, Pierre; Dupont, Damien; Guillot, Jacques; Botterel, Françoise; Wallon, Martine; Gustin, Marie-Paule; Vanhems, Philippe
2017-01-01
Introduction Monitoring fungal aerocontamination is an essential measure to prevent severe invasive aspergillosis (IA) infections in hospitals. One central block among 32 blocks of Edouard Herriot Hospital (EHH) was entirely demolished in 2015, while care activities continued in surrounding blocks. The main objective was to undertake broad environmental monitoring and clinical surveillance of IA cases to document fungal dispersion during major deconstruction work and to assess clinical risk. Methods and analysis A daily environmental survey of fungal loads was conducted in eight wards located near the demolition site. Air was collected inside and outside selected wards by agar impact samplers. Daily spore concentrations were monitored continuously by volumetric samplers at a flow rate of 10 L.min-1. Daily temperature, wind direction and speed as well as relative humidity were recorded by the French meteorological station Meteociel. Aspergillus fumigatus strains stored will be genotyped by multiple-locus, variable-number, tandem-repeat analysis. Antifungal susceptibility will be assessed by E-test strips on Roswell Park Memorial Institute medium supplemented with agar. Ascertaining the adequacy of current environmental monitoring techniques in hospital is of growing importance, considering the rising impact of fungal infections and of curative antifungal costs. The present study could improve the daily management of IA risk during major deconstruction work and generate new data to ameliorate and redefine current guidelines. Ethics and dissemination This study was approved by the clinical research and ethics committees of EHH. PMID:29175886
A new tritium monitor design based on plasma source ion implantation technique
NASA Astrophysics Data System (ADS)
Nassar, Rafat Mohammad
Tritium is an important isotope of hydrogen. The availability of tritium in our environment is manifest through both natural and artificial sources. Consequently, the requirement for tritium handling and usage will continue to increase in the future. An important future contributor is nuclear fusion power plants and facilities. Essential safety regulations and procedures require effective monitoring and measurements of tritium concentrations in workplaces. The unique characteristics of tritium impose an important role on the criteria for its detection and measurement. As tritium decays by the emission of soft beta particles, maximum 18 keV, it cannot be readily detected by commonly used detectors. Specially built monitors are required. Additional complications occur due to the presence of other radioactive isotopes or ambient radiation fields and because of the high diffusivity of tritium. When it is in oxidized form it is 25000 times more hazardous biologically than when in elemental form. Therefore, contamination of the monitor is expected and compound specific monitors are important. A summary is given of the various well known methods of detecting tritium-in-air. This covers the direct as well as the indirect measuring techniques, although each has been continually improved and further developed, nevertheless, each has its own limitations. Ionization chambers cannot discriminate against airborne P emitters. Proportional counters have a narrow operating range, 3-4 decades, and have poor performance in relatively high humid environments and require a dry counting gas. Liquid scintillation counters are sensitive, but inspection of the sample is slow and they produce chemical liquid waste. A new way to improve the sensitivity of detecting tritium with plastic scintillators has been developed. The technique is based on a non-line-of-sight implantation of tritium ions into a 20 mum plastic scintillator using a plasma source ion implantation (PSII) technique, This type of source is different, superior to the line-of-sight implantation and requires no additional beam handling. It is capable of implanting ion species in a broad beam configuration into the entire surface of a target. The technique requires a special ion source with special characteristics of the type obtained from a surfatron plasma source. This ion source has a large high ion density plasma with minimum contamination and produces ions of low temperature. It was constructed to ionize the sampled air and to produce a plasma over a wide range of pressure, 4-0.1 mTorr. A plasma source ion implantation cell was designed and constructed using mathematical modeling with personal computer, to optimize the essential variables of the design and to estimate the implantation rate under different operation conditions. Also, a high voltage pulse modulator was designed and constructed to produce a series of 10 musec pulses (up to 2 MHz) with a maximum magnitude of -60 kV. The developed device was capable of ionizing air samples and implanting the resulting ions into a plastic scintillator. Two different methods to enhance the collection and deposition of the tritium ions, have been proposed and assessed. A movable prototype device for monitoring environmental tritium in air has been designed and constructed. Although this prototype was not fully tested, the primary calculations have shown that measurable concentrations of tritium ions can be collected from an air sample, with tritium activity ranging from 0.3 Bq/cm3 down to 0.03 mBq/cm3, in a short time, to the order of seconds, on-line. This sensitivity fulfills the requirement for environmental monitoring.
Cloud-based privacy-preserving remote ECG monitoring and surveillance.
Page, Alex; Kocabas, Ovunc; Soyata, Tolga; Aktas, Mehmet; Couderc, Jean-Philippe
2015-07-01
The number of technical solutions for monitoring patients in their daily activities is expected to increase significantly in the near future. Blood pressure, heart rate, temperature, BMI, oxygen saturation, and electrolytes are few of the physiologic factors that will soon be available to patients and their physicians almost continuously. The availability and transfer of this information from the patient to the health provider raises privacy concerns. Moreover, current data encryption approaches expose patient data during processing, therefore restricting their utility in applications requiring data analysis. We propose a system that couples health monitoring techniques with analytic methods to permit the extraction of relevant information from patient data without compromising privacy. This proposal is based on the concept of fully homomorphic encryption (FHE). Since this technique is known to be resource-heavy, we develop a proof-of-concept to assess its practicality. Results are presented from our prototype system, which mimics live QT monitoring and detection of drug-induced QT prolongation. Transferring FHE-encrypted QT and RR samples requires about 2 Mbps of network bandwidth per patient. Comparing FHE-encrypted values--for example, comparing QTc to a given threshold-runs quickly enough on modest hardware to alert the doctor of important results in real-time. We demonstrate that FHE could be used to securely transfer and analyze ambulatory health monitoring data. We present a unique concept that could represent a disruptive type of technology with broad applications to multiple monitoring devices. Future work will focus on performance optimizations to accelerate expansion to these other applications. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Eckman, R.; Zawodny, J. M.; Cisewski, M. S.; Flittner, D. E.; McCormick, M. P.; Gasbarre, J. F.; Damadeo, R. P.; Hill, C. A.
2015-12-01
The Stratospheric Aerosol and Gas Experiment III/International Space Station (SAGE III/ISS) is a strategic climate continuity mission which was included in NASA's 2010 plan, "Responding to the Challenge of Climate and Environmental Change: NASA's Plan for a Climate-Centric Architecture for Earth Observations and Applications from Space." SAGE III/ISS continues the long-term, global measurements of trace gases and aerosols begun in 1979 by SAGE I and continued by SAGE II and SAGE III on Meteor 3M. Using a well characterized occultation technique, the SAGE III instrument's spectrometer will measure vertical profiles of ozone, aerosols, water vapor, nitrogen dioxide, and other trace gases relevant to ozone chemistry. The mission will launch in 2016 aboard a Falcon 9 spacecraft.The primary objective of SAGE III/ISS is to monitor the vertical distribution of aerosols, ozone, and other trace gases in the Earth's stratosphere and troposphere to enhance our understanding of ozone recovery and climate change processes in the stratosphere and upper troposphere. SAGE III/ISS will provide data necessary to assess the state of the recovery in the distribution of ozone, extend the SAGE III aerosol measurement record that is needed by both climate models and ozone models, and gain further insight into key processes contributing to ozone and aerosol variability. The multi-decadal SAGE ozone and aerosol data sets have undergone intense community scrutiny for accuracy and stability. SAGE ozone data have been used to monitor the effectiveness of the Montreal Protocol.The ISS inclined orbit of 51.6 degrees is ideal for SAGE III measurements because the orbit permits solar occultation measurement coverage to approximately +/- 70 degrees of latitude. SAGE III/ISS will make measurements using the solar occultation measurement technique, lunar occultation measurement technique, and the limb scattering measurement technique. In this presentation, we describe the SAGE III/ISS mission, its implementation, the current status of the instrument, and the testing that took place this past summer. We will focus principally on the science to be conducted by the mission.
Ground Penetrating Radar technique for railway track characterization in Portugal
NASA Astrophysics Data System (ADS)
De Chiara, Francesca; Fontul, Simona; Fortunato, Eduardo; D'Andrea, Antonio
2013-04-01
Maintenance actions are significant for transport infrastructures but, today, costs have to be necessary limited. A proper quality control since the construction phase is a key factor for a long life cycle and for a good economy policy. For this reason, suitable techniques have to be chosen and non-destructive tests represent an efficient solution, as they allow to evaluate infrastructure characteristics in a continuous or quasi-continuous way, saving time and costs, enabling to make changes if tests results do not comply with the project requirements. Ground Penetrating Radar (GPR) is a quick and effective technique to evaluate infrastructure condition in a continuous manner, replacing or reducing the use of traditional drilling method. GPR application to railways infrastructures, during construction and monitoring phase, is relatively recent. It is based on the measuring of layers thicknesses and detection of structural changes. It also enables the assessment of materials properties that constitute the infrastructure and the evaluation of the different types of defects such as ballast pockets, fouled ballast, poor drainage, subgrade settlement and transitions problems. These deteriorations are generally the causes of vertical deviations in track geometry and they cannot be detected by the common monitoring procedures, namely the measurements of track geometry. Moreover, the development of new GPR systems with higher antenna frequencies, better data acquisition systems, more user friendly software and new algorithms for calculation of materials properties can lead to a regular use of GPR. Therefore, it represents a reliable technique to assess track geometry problems and consequently to improve maintenance planning. In Portugal, rail inspection is performed with Plasser & Theurer EM120 equipment and recently 400 MHz IDS antennas were installed on it. GPR tests were performed on the Portuguese rail network and, as case study in this paper, a renewed track was considered. The aim was to detect, along the track, changes of the layers in terms of both thicknesses and materials characteristics by using specific software, Railwaydoctor. Different test campaigns were studied in order to determine and compare the materials dielectric constants that can be influenced by water content values, due to measurements performed in different seasons.
Axillary nerve monitoring during arthroscopic shoulder stabilization.
Esmail, Adil N; Getz, Charles L; Schwartz, Daniel M; Wierzbowski, Lawrence; Ramsey, Matthew L; Williams, Gerald R
2005-06-01
This study evaluated the ability of a novel intraoperative neurophysiologic monitoring method used to locate the axillary nerve, predict relative capsule thickness, and identify impending injury to the axillary nerve during arthroscopic thermal capsulorrhaphy of the shoulder. Prospective cohort study. Twenty consecutive patients with glenohumeral instability were monitored prospectively during arthroscopic shoulder surgery. Axillary nerve mapping and relative capsule thickness estimates were recorded before the stabilization portion of the procedure. During labral repair and/or thermal capsulorrhaphy, continuous and spontaneous electromyography recorded nerve activity. In addition, trans-spinal motor-evoked potentials of the fourth and fifth cervical roots and brachial plexus electrical stimulation, provided real-time information about nerve integrity. Axillary nerve mapping and relative capsule thickness were recorded in all patients. Continuous axillary nerve monitoring was successfully performed in all patients. Eleven of the 20 patients underwent thermal capsulorrhaphy alone or in combination with arthroscopic labral repair. Nine patients underwent arthroscopic labral repair alone. In 4 of the 11 patients who underwent thermal capsulorrhaphy, excessive spontaneous neurotonic electromyographic activity was noted, thereby altering the pattern of heat application by the surgeon. In 1 of these 4 patients, a small increase in the motor latency was noted after the procedure but no clinical deficit was observed. There were no neuromonitoring or clinical neurologic changes observed in the labral repair group without thermal application. At last follow-up, no patient in either group had any clinical evidence of nerve injury or complications from neurophysiologic monitoring. We successfully evaluated the use of intraoperative nerve monitoring to identify axillary nerve position, capsule thickness, and provide real-time identification of impending nerve injury and function during shoulder thermal capsulorrhaphy. The use of intraoperative nerve monitoring altered the heat application technique in 4 of 11 patients and may have prevented nerve injury. Level II, prospective cohort study.
An autonomous structural health monitoring solution
NASA Astrophysics Data System (ADS)
Featherston, Carol A.; Holford, Karen M.; Pullin, Rhys; Lees, Jonathan; Eaton, Mark; Pearson, Matthew
2013-05-01
Combining advanced sensor technologies, with optimised data acquisition and diagnostic and prognostic capability, structural health monitoring (SHM) systems provide real-time assessment of the integrity of bridges, buildings, aircraft, wind turbines, oil pipelines and ships, leading to improved safety and reliability and reduced inspection and maintenance costs. The implementation of power harvesting, using energy scavenged from ambient sources such as thermal gradients and sources of vibration in conjunction with wireless transmission enables truly autonomous systems, reducing the need for batteries and associated maintenance in often inaccessible locations, alongside bulky and expensive wiring looms. The design and implementation of such a system however presents numerous challenges. A suitable energy source or multiple sources capable of meeting the power requirements of the system, over the entire monitoring period, in a location close to the sensor must be identified. Efficient power management techniques must be used to condition the power and deliver it, as required, to enable appropriate measurements to be taken. Energy storage may be necessary, to match a continuously changing supply and demand for a range of different monitoring states including sleep, record and transmit. An appropriate monitoring technique, capable of detecting, locating and characterising damage and delivering reliable information, whilst minimising power consumption, must be selected. Finally a wireless protocol capable of transmitting the levels of information generated at the rate needed in the required operating environment must be chosen. This paper considers solutions to some of these challenges, and in particular examines SHM in the context of the aircraft environment.
SPECTROSCOPIC ONLINE MONITORING FOR PROCESS CONTROL AND SAFEGUARDING OF RADIOCHEMICAL STREAMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryan, Samuel A.; Levitskaia, Tatiana G.
2013-09-29
There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the used nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved used nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. This paper summarizes application of the absorption and vibrational spectroscopicmore » techniques supplemented by physicochemical measurements for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and spectrophotometric techniques for online real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. These techniques demonstrate robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. Satisfactory prediction of the analytes concentrations in these preliminary experiments warrants further development of the spectroscopy-based methods for radiochemical process control and safeguarding. Additionally, the ability to identify material intentionally diverted from a liquid-liquid extraction contactor system was successfully tested using on-line process monitoring as a means to detect the amount of material diverted. A chemical diversion and detection from a liquid-liquid extraction scheme was demonstrated using a centrifugal contactor system operating with the simulant PUREX extraction system of Nd(NO3)3/nitric acid aqueous phase and TBP/n-dodecane organic phase. During a continuous extraction experiment, a portion of the feed from a counter-current extraction system was diverted while the spectroscopic on-line process monitoring system was simultaneously measuring the feed, raffinate and organic products streams. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from the known mass of sample directly taken (diverted) from system feed solution.« less
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2013 CFR
2013-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2012 CFR
2012-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2014 CFR
2014-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2011 CFR
2011-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Monitoring continued equivalence. 26.45 Section 26...
40 CFR 75.40 - General demonstration requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTINUOUS EMISSION MONITORING Alternative Monitoring Systems § 75.40 General demonstration... continuous emission monitoring system may apply to the Administrator for approval of an alternative monitoring system (or system component) to determine average hourly emission data for SO2, NOX, and/or...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zemo, D.A.; Pierce, Y.G.; Gallinatti, J.D.
Cone penetrometer testing (CPT), combined with discrete-depth ground water sampling methods, can significantly reduce the time and expense required to characterize large sites that have multiple aquifers. Results from the screening site characterization can then be used to design and install a cost-effective monitoring well network. At a site in northern California, it was necessary to characterize the stratigraphy and the distribution of volatile organic compounds (VOCs). To expedite characterization, a five-week field screening program was implemented that consisted of a shallow ground water survey, CPT soundings and pore-pressure measurements, and discrete-depth ground water sampling. Based on continuous lithologic informationmore » provided by the CPT soundings, four predominantly coarse-grained, water yielding stratigraphic packages were identified. Seventy-nine discrete-depth ground water samples were collected using either shallow ground water survey techniques, the BAT Enviroprobe, or the QED HydroPunch I, depending on subsurface conditions. Using results from these efforts, a 20-well monitoring network was designed and installed to monitor critical points within each stratigraphic package. Good correlation was found for hydraulic head and chemical results between discrete-depth screening data and monitoring well data. Understanding the vertical VOC distribution and concentrations produced substantial time and cost savings by minimizing the number of permanent monitoring wells and reducing the number of costly conductor casings that had to be installed. Additionally, significant long-term cost savings will result from reduced sampling costs, because fewer wells comprise the monitoring network. The authors estimate these savings to be 50% for site characterization costs, 65% for site characterization time, and 60% for long-term monitoring costs.« less
Subcutaneous transplantation of embryonic pancreas for correction of type 1 diabetes
Gunawardana, Subhadra C.; Benninger, Richard K. P.; Piston, David W.
2009-01-01
Islet transplantation is a promising therapeutic approach for type 1 diabetes. However, current success rates are low due to progressive graft failure in the long term and inability to monitor graft development in vivo. Other limitations include the necessity of initial invasive surgery and continued immunosuppressive therapy. We report an alternative transplantation strategy with the potential to overcome these problems. This technique involves transplantation of embryonic pancreatic tissue into recipients’ subcutaneous space, eliminating the need for invasive surgery and associated risks. Current results in mouse models of type 1 diabetes show that embryonic pancreatic transplants in the subcutaneous space can normalize blood glucose homeostasis and achieve extensive endocrine differentiation and vascularization. Furthermore, modern imaging techniques such as two-photon excitation microscopy (TPEM) can be employed to monitor transplants through the intact skin in a completely noninvasive manner. Thus, this strategy is a convenient alternative to islet transplantation in diabetic mice and has the potential to be translated to human clinical applications with appropriate modifications. PMID:19066321
Wearable sensor systems for infants.
Zhu, Zhihua; Liu, Tao; Li, Guangyi; Li, Tong; Inoue, Yoshio
2015-02-05
Continuous health status monitoring of infants is achieved with the development and fusion of wearable sensing technologies, wireless communication techniques and a low energy-consumption microprocessor with high performance data processing algorithms. As a clinical tool applied in the constant monitoring of physiological parameters of infants, wearable sensor systems for infants are able to transmit the information obtained inside an infant's body to clinicians or parents. Moreover, such systems with integrated sensors can perceive external threats such as falling or drowning and warn parents immediately. Firstly, the paper reviews some available wearable sensor systems for infants; secondly, we introduce the different modules of the framework in the sensor systems; lastly, the methods and techniques applied in the wearable sensor systems are summarized and discussed. The latest research and achievements have been highlighted in this paper and the meaningful applications in healthcare and behavior analysis are also presented. Moreover, we give a lucid perspective of the development of wearable sensor systems for infants in the future.
Volcanic hazards and their mitigation: progress and problems
Tilling, R.I.
1989-01-01
A review of hazards mitigation approaches and techniques indicates that significant advances have been made in hazards assessment, volcano monioring, and eruption forecasting. For example, the remarkable accuracy of the predictions of dome-building events at Mount St. Helens since June 1980 is unprecedented. Yet a predictive capability for more voluminous and explosive eruptions still has not been achieved. Studies of magma-induced seismicity and ground deformation continue to provide the most systematic and reliable data for early detection of precursors to eruptions and shallow intrusions. In addition, some other geophysical monitoring techniques and geochemical methods have been refined and are being more widely applied and tested. Comparison of the four major volcanic disasters of the 1980s (Mount St. Helens, U.S.A. (1980), El Chichon, Mexico (1982); Galunggung, Indonesia (1982); and Nevado del Ruiz, Colombia (1985)) illustrates the importance of predisaster geoscience studies, volcanic hazards assessments, volcano monitoring, contingency planning, and effective communications between scientists and authorities. -from Author
Mourning dove hunting regulation strategy based on annual harvest statistics and banding data
Otis, D.L.
2006-01-01
Although managers should strive to base game bird harvest management strategies on mechanistic population models, monitoring programs required to build and continuously update these models may not be in place. Alternatively, If estimates of total harvest and harvest rates are available, then population estimates derived from these harvest data can serve as the basis for making hunting regulation decisions based on population growth rates derived from these estimates. I present a statistically rigorous approach for regulation decision-making using a hypothesis-testing framework and an assumed framework of 3 hunting regulation alternatives. I illustrate and evaluate the technique with historical data on the mid-continent mallard (Anas platyrhynchos) population. I evaluate the statistical properties of the hypothesis-testing framework using the best available data on mourning doves (Zenaida macroura). I use these results to discuss practical implementation of the technique as an interim harvest strategy for mourning doves until reliable mechanistic population models and associated monitoring programs are developed.
Wearable Sensor Systems for Infants
Zhu, Zhihua; Liu, Tao; Li, Guangyi; Li, Tong; Inoue, Yoshio
2015-01-01
Continuous health status monitoring of infants is achieved with the development and fusion of wearable sensing technologies, wireless communication techniques and a low energy-consumption microprocessor with high performance data processing algorithms. As a clinical tool applied in the constant monitoring of physiological parameters of infants, wearable sensor systems for infants are able to transmit the information obtained inside an infant's body to clinicians or parents. Moreover, such systems with integrated sensors can perceive external threats such as falling or drowning and warn parents immediately. Firstly, the paper reviews some available wearable sensor systems for infants; secondly, we introduce the different modules of the framework in the sensor systems; lastly, the methods and techniques applied in the wearable sensor systems are summarized and discussed. The latest research and achievements have been highlighted in this paper and the meaningful applications in healthcare and behavior analysis are also presented. Moreover, we give a lucid perspective of the development of wearable sensor systems for infants in the future. PMID:25664432
Contact thermal shock test of ceramics
NASA Technical Reports Server (NTRS)
Rogers, W. P.; Emery, A. F.
1992-01-01
A novel quantitative thermal shock test of ceramics is described. The technique employs contact between a metal-cooling rod and hot disk-shaped specimen. In contrast with traditional techniques, the well-defined thermal boundary condition allows for accurate analyses of heat transfer, stress, and fracture. Uniform equibiaxial tensile stresses are induced in the center of the test specimen. Transient specimen temperature and acoustic emission are monitored continuously during the thermal stress cycle. The technique is demonstrated with soda-lime glass specimens. Experimental results are compared with theoretical predictions based on a finite-element method thermal stress analysis combined with a statistical model of fracture. Material strength parameters are determined using concentric ring flexure tests. Good agreement is found between experimental results and theoretical predictions of failure probability as a function of time and initial specimen temperature.
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2014 CFR
2014-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2014 CFR
2014-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Monitoring continued equivalence. 26.15 Section 26...
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2013 CFR
2013-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Monitoring continued equivalence. 26.15 Section 26...
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2012 CFR
2012-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Monitoring continued equivalence. 26.15 Section 26...
Adaptive model reduction for continuous systems via recursive rational interpolation
NASA Technical Reports Server (NTRS)
Lilly, John H.
1994-01-01
A method for adaptive identification of reduced-order models for continuous stable SISO and MIMO plants is presented. The method recursively finds a model whose transfer function (matrix) matches that of the plant on a set of frequencies chosen by the designer. The algorithm utilizes the Moving Discrete Fourier Transform (MDFT) to continuously monitor the frequency-domain profile of the system input and output signals. The MDFT is an efficient method of monitoring discrete points in the frequency domain of an evolving function of time. The model parameters are estimated from MDFT data using standard recursive parameter estimation techniques. The algorithm has been shown in simulations to be quite robust to additive noise in the inputs and outputs. A significant advantage of the method is that it enables a type of on-line model validation. This is accomplished by simultaneously identifying a number of models and comparing each with the plant in the frequency domain. Simulations of the method applied to an 8th-order SISO plant and a 10-state 2-input 2-output plant are presented. An example of on-line model validation applied to the SISO plant is also presented.
Currie, Marian J; Huang, Hsin-Chia Carol; Litton, Edward; Wibrow, Bradley; Lopez, Violeta; Haren, Frank Van
2018-01-01
Introduction Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals’ physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. Key measures The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. Methods and analysis A prospective, single centre observational design with a within subjects’ assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and −3 (moderate sedation) and an anticipated length of stay >24 hours. Patients’ sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients’ self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients’ perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. Ethics and dissemination The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. Trial registration number ACTRN12615000945527; Pre-results. PMID:29358448
Delaney, Lori J; Currie, Marian J; Huang, Hsin-Chia Carol; Litton, Edward; Wibrow, Bradley; Lopez, Violeta; Haren, Frank Van
2018-01-21
Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals' physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. A prospective, single centre observational design with a within subjects' assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and -3 (moderate sedation) and an anticipated length of stay >24 hours. Patients' sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients' self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients' perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. ACTRN12615000945527; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Continuing global monitoring of anthropogenic and volcanic SO2 sources from Aura/OMI to SNPP/OMPS
NASA Astrophysics Data System (ADS)
Li, C.; Krotkov, N. A.; Carn, S. A.; Joiner, J.; McLinden, C. A.; Fioletov, V.
2017-12-01
Sulfur dioxide (SO2) is an important trace gas that has significant impacts on air quality, the climate, and stratospheric ozone. It is predominantly emitted from anthropogenic sources such as coal-fired power plants and smelters, but also has sizable sources from volcanic activity. The Ozone Monitoring Instrument (OMI) aboard NASA's Earth Observing System (EOS) Aura spacecraft has been providing global observations of both anthropogenic and volcanic SO2 since its launch in 2004. The Ozone Mapping and Profiler Suite (OMPS) nadir mapper, launched aboard the NASA/NOAA Suomi National Polar-orbiting Partnership (SNPP) satellite in 2011, will continue the 13+ year OMI SO2 time series. However, it is a significant challenge to build a coherent data record between OMI and OMPS, as the SO2 signal is relatively weak and its retrieval is subject to a number of interferences such as ozone absorption. Additionally, the two instruments also have different spectral and spatial resolutions that result in different sensitivities to SO2. Even a relatively small error in retrievals, due to either algorithmic or instrumental factors, may lead to a large inter-instrument bias in SO2. In this presentation, we report on our latest effort and progress in developing EOS continuity SNPP/OMPS SO2 products. We have applied a consistent retrieval technique based on principal component analysis (PCA) of measured radiance data to both OMI and OMPS. We show that the PCA retrieval technique, which extracts principal components (PCs) from measured radiances and applies these PCs in spectral fitting to minimize the effects of various interfering processes, is capable of producing highly consistent OMI and OMPS SO2 data for both anthropogenic sources and large volcanic eruptions. To gain a quantitative understanding of the two instruments' capabilities of monitoring SO2 sources, we have also applied a new emission estimation technique that combines satellite SO2 and wind information to both of them. This method allows SO2 emissions from 500 sources worldwide to be detected and quantified from OMI data. The OMPS-based emission estimates using the same method agree well with OMI-based ones, although OMPS detects fewer of the smaller sources seen by OMI, owing to its coarser spatial resolution.
[Technological innovations in radiation oncology require specific quality controls].
Lenaerts, E; Mathot, M
2014-01-01
During the last decade, the field of radiotherapy has benefited from major technological innovations and continuously improving treatment efficacy, comfort and safety of patients. This mainly concerns the imaging techniques that allow 4D CT scan recording the respiratory phases, on-board imaging on linear accelerators that ensure perfect positioning of the patient for treatment and irradiation techniques that reduce very significantly the duration of treatment sessions without compromising quality of the treatment plan, including IMRT (Intensity Modulated Radiation Therapy) and VMAT (Volumetric Modulated Arc therapy). In this context of rapid technological change, it is the responsibility of medical physicists to regularly and precisely monitor the perfect functioning of new techniques to ensure patient safety. This requires the use of specific quality control equipment best suited to these new techniques. We will briefly describe the measurement system Delta4 used to control individualized treatment plan for each patient treated with VMAT technology.
A Novel Application of Ultrasonic Imaging to Study Smoldering Combustion
NASA Technical Reports Server (NTRS)
Tse, S. D.; Anthenien, R. A.; Fernandez-Pello, A. Carlos; Miyasaka, K.
1997-01-01
An ultrasonic imaging technique has been developed to examine the propagation of a smolder reaction within a porous combustible material. The technique provides information about the location of a propagating smolder front, as well as line-of-sight average permeability variations of the smoldering material. The method utilizes the observation that transmission of an ultrasonic signal through a porous material increases with permeability. Since a propagating smolder reaction leaves behind char with a higher permeability than the original material, ultrasound transmission can be employed to monitor smolder progress. The technique can also be used to track the char evolution as it continues to react. Experiments are presented where the technique is applied to smoldering combustion in a two-dimensional geometry. The results have furthered the understanding of two-dimensional smolder, especially in identifying the controlling mechanisms leading to the transition from smoldering to flaming. The applicability of ultrasonic tomography to smoldering combustion has also been investigated.
Passive monitoring for near surface void detection using traffic as a seismic source
NASA Astrophysics Data System (ADS)
Zhao, Y.; Kuzma, H. A.; Rector, J.; Nazari, S.
2009-12-01
In this poster we present preliminary results based on our several field experiments in which we study seismic detection of voids using a passive array of surface geophones. The source of seismic excitation is vehicle traffic on nearby roads, which we model as a continuous line source of seismic energy. Our passive seismic technique is based on cross-correlation of surface wave fields and studying the resulting power spectra, looking for "shadows" caused by the scattering effect of a void. High frequency noise masks this effect in the time domain, so it is difficult to see on conventional traces. Our technique does not rely on phase distortions caused by small voids because they are generally too tiny to measure. Unlike traditional impulsive seismic sources which generate highly coherent broadband signals, perfect for resolving phase but too weak for resolving amplitude, vehicle traffic affords a high power signal a frequency range which is optimal for finding shallow structures. Our technique results in clear detections of an abandoned railroad tunnel and a septic tank. The ultimate goal of this project is to develop a technology for the simultaneous imaging of shallow underground structures and traffic monitoring near these structures.
Fortuna, A O; Gurd, J R
1999-01-01
During certain medical procedures, it is important to continuously measure the respiratory flow of a patient, as lack of proper ventilation can cause brain damage and ultimately death. The monitoring of the ventilatory condition of a patient is usually performed with the aid of flowmeters. However, water and other secretions present in the expired air can build up and ultimately block a traditional, restriction-based flowmeter; by using an orifice plate flowmeter, such blockages are minimized. This paper describes the design of an orifice plate flowmetering system including, especially, a description of the numerical and computational techniques adopted in order to simulate human respiratory and sinusoidal air flow across various possible designs for the orifice plate flowmeter device. Parallel computation and multigrid techniques were employed in order to reduce execution time. The simulated orifice plate was later built and tested under unsteady sinusoidal flows. Experimental tests show reasonable agreement with the numerical simulation, thereby reinforcing the general hypothesis that computational exploration of the design space is sufficiently accurate to allow designers of such systems to use this in preference to the more traditional, mechanical prototyping techniques.
Understanding fetal physiology and second line monitoring during labor.
Garabedian, C; De Jonckheere, J; Butruille, L; Deruelle, P; Storme, L; Houfflin-Debarge, V
2017-02-01
Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon...
NASA Astrophysics Data System (ADS)
Qin, Rufu; Lin, Liangzhao
2017-06-01
Coastal seiches have become an increasingly important issue in coastal science and present many challenges, particularly when attempting to provide warning services. This paper presents the methodologies, techniques and integrated services adopted for the design and implementation of a Seiches Monitoring and Forecasting Integration Framework (SMAF-IF). The SMAF-IF is an integrated system with different types of sensors and numerical models and incorporates the Geographic Information System (GIS) and web techniques, which focuses on coastal seiche events detection and early warning in the North Jiangsu shoal, China. The in situ sensors perform automatic and continuous monitoring of the marine environment status and the numerical models provide the meteorological and physical oceanographic parameter estimates. A model outputs processing software was developed in C# language using ArcGIS Engine functions, which provides the capabilities of automatically generating visualization maps and warning information. Leveraging the ArcGIS Flex API and ASP.NET web services, a web based GIS framework was designed to facilitate quasi real-time data access, interactive visualization and analysis, and provision of early warning services for end users. The integrated framework proposed in this study enables decision-makers and the publics to quickly response to emergency coastal seiche events and allows an easy adaptation to other regional and scientific domains related to real-time monitoring and forecasting.
Terrestrial photography as a complementary measurement in weather stations for snow monitoring
NASA Astrophysics Data System (ADS)
Pimentel, Rafael; José Pérez-Palazón, María; Herrero, Javier; José Polo, María
2015-04-01
Snow monitoring constitutes a basic key to know snow behaviour and evolution, which have particular features in semiarid regions (i.e. highly strong spatiotemporal variability, and the occurrence of several accumulation-melting cycles throughout the year). On one hand, traditional snow observation, such as snow surveys and snow pillows have the inconvenience of a limited accessibility during snow season and the impossibility to cover a vast extension. On the other hand, satellite remote sensing techniques, largely employed in medium to large scale regional studies, has the disadvantage of a fixed spatial and temporal resolutions which in some cases are not able to reproduce snow processes at small scale. An economic alternative is the use of terrestrial photography which scales are adapted to the study problem. At the microscale resolution permits the continuous monitoring of snow, adapting the resolution of the observation to the scales of the processes. Besides its use as raw observation datasets to calibrate and validate models' results, terrestrial photography constitutes valuable information to complement weather stations observations. It allows the discriminating possible mistakes in meteorological observations (i.e. overestimation on rain measurements) and a better understanding of snow behaviour against certain weather agents (i.e. blowing snow). Thus, terrestrial photography is a feasible and convenient technique to be included in weather monitoring stations in mountainous areas in semiarid regions.
[Remote sensing monitoring and screening for urban black and odorous water body: A review.
Shen, Qian; Zhu, Li; Cao, Hong Ye
2017-10-01
Continuous improvement of urban water environment and overall control of black and odorous water body are not merely national strategic needs with the action plan for prevention and treatment of water pollution, but also the hot issues attracting the attention of people. Most previous researches concentrated on the study of cause, evaluation and treatment measures of this phenomenon, and there are few researches on the monitoring using remote sensing, which is often a strain to meet the national needs of operational monitoring. This paper mainly summarized the urgent research problems, mainly including the identification and classification standard, research on the key technologies, and the frame of remote sensing screening systems for the urban black and odorous water body. The main key technologies were concluded too, including the high spatial resolution image preprocessing and extraction technique for black and odorous water body, the extraction of water information in city zones, the classification of the black and odorous water, and the identification and classification technique based on satellite-sky-ground remote sensing. This paper summarized the research progress and put forward research ideas of monitoring and screening urban black and odorous water body via high spatial resolution remote sensing technology, which would be beneficial to having an overall grasp of spatial distribution and improvement progress of black and odorous water body, and provide strong technical support for controlling urban black and odorous water body.
Benifla, J L; Goffinet, F; Darai, E; Madelenat, P
1994-12-01
Transabdominal amnioinfusion can be used to facilitate external cephalic version. Our technique involves filling the uterine cavity with 700 or 900 mL of 37C saline under continuous echographic monitoring. External cephalic version is done the next morning. We have used this procedure in six women, all of whom had previous unsuccessful attempts at external cephalic version. After amnioinfusion, all six patients were converted to cephalic presentation and delivered normally, without obstetric or neonatal complications.
NASA Technical Reports Server (NTRS)
Rosen, Paul A.
2012-01-01
This lecture was just a taste of radar remote sensing techniques and applications. Other important areas include Stereo radar grammetry. PolInSAR for volumetric structure mapping. Agricultural monitoring, soil moisture, ice-mapping, etc. The broad range of sensor types, frequencies of observation and availability of sensors have enabled radar sensors to make significant contributions in a wide area of earth and planetary remote sensing sciences. The range of applications, both qualitative and quantitative, continue to expand with each new generation of sensors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix B or appendix F requirements to evaluate continuous emission monitoring systems? 62.15190 Section... evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix B or appendix F requirements to evaluate continuous emission monitoring systems? 62.15190 Section... evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission...
Process Monitoring Evaluation and Implementation for the Wood Abrasive Machining Process
Saloni, Daniel E.; Lemaster, Richard L.; Jackson, Steven D.
2010-01-01
Wood processing industries have continuously developed and improved technologies and processes to transform wood to obtain better final product quality and thus increase profits. Abrasive machining is one of the most important of these processes and therefore merits special attention and study. The objective of this work was to evaluate and demonstrate a process monitoring system for use in the abrasive machining of wood and wood based products. The system developed increases the life of the belt by detecting (using process monitoring sensors) and removing (by cleaning) the abrasive loading during the machining process. This study focused on abrasive belt machining processes and included substantial background work, which provided a solid base for understanding the behavior of the abrasive, and the different ways that the abrasive machining process can be monitored. In addition, the background research showed that abrasive belts can effectively be cleaned by the appropriate cleaning technique. The process monitoring system developed included acoustic emission sensors which tended to be sensitive to belt wear, as well as platen vibration, but not loading, and optical sensors which were sensitive to abrasive loading. PMID:22163477
Problems, pitfalls and probes: Welcome to the jungle of electrochemical noise technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edgemon, G.L.
1998-02-19
The rise in electrochemical noise (EN) as a corrosion monitoring technique has resulted in unique problems associated with the field application of this method. Many issues relate to the design of the EN probe electrodes. The ability of an electrochemical noise monitoring system to identify and discriminate between localized corrosion mechanisms is related primarily to the capability of the probe to separate the corrosion cell anode from the corresponding cathode. Effectiveness of this separation is largely determined by the details of and the proper design of the probe that is in the environment of interest. No single probe design ormore » geometry can be effectively use in every situation to monitor all types of corrosion. In this paper the authors focus on a case study and probe development history related to monitoring corrosion in an extremely hostile environment using EN. While the ultimate application of EN was and continues to be successful, the case study shows that patience and persistence was necessary to meet and properly implement the monitoring program. Other possible source of problems and frustration with implementing EN are also discussed.« less
NASA Technical Reports Server (NTRS)
Tiwari, Anil
1995-01-01
Research effort was directed towards developing a near real-time, acousto-ultrasonic (AU), nondestructive evaluation (NDE) tool to study the failure mechanisms of ceramic composites. Progression of damage is monitored in real-time by observing the changes in the received AU signal during the actual test. During the real-time AU test, the AU signals are generated and received by the AU transducers attached to the specimen while it is being subjected to increasing quasi-static loads or cyclic loads (10 Hz, R = 1.0). The received AU signals for 64 successive pulses were gated in the time domain (T = 40.96 micro sec) and then averaged every second over ten load cycles and stored in a computer file during fatigue tests. These averaged gated signals are representative of the damage state of the specimen at that point of its fatigue life. This is also the first major attempt in the development and application of real-time AU for continuously monitoring damage accumulation during fatigue without interrupting the test. The present work has verified the capability of the AU technique to assess the damage state in silicon carbide/calcium aluminosilicate (SiC/CAS) and silicon carbide/ magnesium aluminosilicate (SiC/MAS) ceramic composites. Continuous monitoring of damage initiation and progression under quasi-static ramp loading in tension to failure of unidirectional and cross-ply SiC/CAS and quasi-isotropic SiC/MAS ceramic composite specimens at room temperature was accomplished using near real-time AU parameters. The AU technique was shown to be able to detect the stress levels for the onset and saturation of matrix cracks, respectively. The critical cracking stress level is used as a design stress for brittle matrix composites operating at elevated temperatures. The AU technique has found that the critical cracking stress level is 10-15% below the level presently obtained for design purposes from analytical models. An acousto-ultrasonic stress-strain response (AUSSR) model for unidirectional and cross-ply ceramic composites was formulated. The AUSSR model predicts the strain response to increasing stress levels using real-time AU data and classical laminated plate theory. The Weibull parameters of the AUSSR model are used to calculate the design stress for thermo-structural applications. Real-time AU together with the AUSSR model was used to study the failure mechanisms of SiC/CAS ceramic composites under static and fatigue loading. An S-N curve was generated for a cross-ply SiC/CAS ceramic composite material. The AU results are corroborated and complemented by other NDE techniques, namely, in-situ optical microscope video recordings and edge replication.
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2012 CFR
2012-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2014 CFR
2014-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2013 CFR
2013-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
The verification test was conducted oer a period of 30 days (October 1 to October 31, 2008) and involved the continuous operation of duplicate semi-continuous monitoring technologies at the Burdens Creek Air Monitoring Site, an existing ambient-air monitoring station located near...
Power Management and SRAM for Energy-Autonomous and Low-Power Systems
NASA Astrophysics Data System (ADS)
Chen, Gregory K.
We demonstrate the two first-known, complete, self-powered millimeter-scale computer systems. These microsystems achieve zero-net-energy operation using solar energy harvesting and ultra-low-power circuits. A medical implant for monitoring intraocular pressure (IOP) is presented as part of a treatment for glaucoma. The 1.5mm3 IOP monitor is easily implantable because of its small size and measures IOP with 0.5mmHg accuracy. It wirelessly transmits data to an external wand while consuming 4.70nJ/bit. This provides rapid feedback about treatment efficacies to decrease physician response time and potentially prevent unnecessary vision loss. A nearly-perpetual temperature sensor is presented that processes data using a 2.1muW near-threshold ARMRTM Cortex-M3(TM) muP that provides a widely-used and trusted programming platform. Energy harvesting and power management techniques for these two microsystems enable energy-autonomous operation. The IOP monitor harvests 80nW of solar power while consuming only 5.3nW, extending lifetime indefinitely. This allows the device to provide medical information for extended periods of time, giving doctors time to converge upon the best glaucoma treatment. The temperature sensor uses on-demand power delivery to improve low-load dc-dc voltage conversion efficiency by 4.75x. It also performs linear regulation to deliver power with low noise, improved load regulation, and tight line regulation. Low-power high-throughput SRAM techniques help millimeter-scale microsystems meet stringent power budgets. VDD scaling in memory decreases energy per access, but also decreases stability margins. These margins can be improved using sizing, VTH selection, and assist circuits, as well as new bitcell designs. Adaptive Crosshairs modulation of SRAM power supplies fixes 70% of parametric failures. Half-differential SRAM design improves stability, reducing VMIN by 72mV. The circuit techniques for energy autonomy presented in this dissertation enable millimeter-scale microsystems for medical implants, such as blood pressure and glucose sensors, as well as non-medical applications, such as supply chain and infrastructure monitoring. These pervasive sensors represent the continuation of Bell's Law, which accurately traces the evolution of computers as they have become smaller, more numerous, and more powerful. The development of millimeter-scale massively-deployed ubiquitous computers ensures the continued expansion and profitability of the semiconductor industry. NanoWatt circuit techniques will allow us to meet this next frontier in IC design.
Xu, Yan; Zhang, Dong-Yang; Meng, Xiang-Yun; Liu, Xi; Sheng, Sheng; Wu, Guo-Hua; Wang, Jun; Wu, Fu-An
2017-04-15
Today, continuous processing is regarded as an effective on-demand production technique of pharmaceuticals. Homemade microreactors packed with immobilized lipase under continuous-flow conditions were first applied to tailor the production of high-value caffeic acid phenethyl ester (CAPE) from methyl caffeate (MC) and 2-phenylethanol (PE) in cyclohexane via transesterification; however, this method is challenging due to the lack of a rapid platform for monitoring caffeates in microfluidic biocatalysis. The reactants were directly analyzed using Direct Analysis in Real Time Mass Spectrometry (DART-MS), and the corresponding ionization parameters were investigated. Special ions produced from MC (parent ion m/z 192.87 and product ion m/z 133.44) and CAPE (parent ion m/z 282.93 and product ion m/z 178.87) were determined using DART-MS 2 in the negative ion mode. The peak areas of the select reaction monitoring (SRM) signals were calculated to develop the standard curves for quantitative analyses of the concentration. Reasonable linear regression equations of MC and CAPE were obtained in the range of 3.125-50.000mg/L, with linear coefficients (R 2 ) of 0.9515 and 0.9973, limits of detection (LOD) of 0.005 and 0.003mg/L, limits of quantification (LOQ) of 0.02 and 0.01mg/L, and recovery ranges of 92.50-97.11% and 90.11-97.60%, respectively. The results using DART-MS 2 were in good agreement with those using conventional High-Performance Liquid Chromatography with a UV detector (HPLC-UV) and were successfully applied to monitor the kinetics constants and mass transfer coefficients in a continuous-flow packed bed microreactor. Thus, the DART-MS 2 method is an efficient tool for analyzing caffeates in microfluidic biocatalysis with limited sample preparation and short operating time. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Burba, George; Madsen, Rodney; Feese, Kristin
2014-05-01
Flux stations have been widely used to monitor emission rates of CO2 from various ecosystems for climate research for over 30 years [1]. The stations provide accurate and continuous measurements of CO2 emissions with high temporal resolution. Time scales range from 20 times per second for gas concentrations, to 15-minute, hourly, daily, and multi-year periods. The emissions are measured from the upwind area ranging from thousands of square meters to multiple square kilometers, depending on the measurement height. The stations can nearly instantaneously detect rapid changes in emissions due to weather events, as well as changes caused by variations in human-triggered events (pressure leaks, control releases, etc.). Stations can also detect any slow changes related to seasonal dynamics and human-triggered low-frequency processes (leakage diffusion, etc.). In the past, station configuration, data collection and processing were highly-customized, site-specific and greatly dependent on "school-of-thought" practiced by a particular research group. In the last 3-5 years, due to significant efforts of global and regional CO2 monitoring networks (e.g., FluxNet, Ameriflux, Carbo-Europe, ICOS, etc.) and technological developments, the flux station methodology became fairly standardized and processing protocols became quite uniform [1]. A majority of current stations compute CO2 emission rates using the eddy covariance method, one of the most direct and defensible micrometeorological techniques [1]. Presently, over 600 such flux stations are in operation in over 120 countries, using permanent and mobile towers or moving platforms (e.g., automobiles, helicopters, and airplanes). Atmospheric monitoring of emission rates using such stations is now recognized as an effective method in regulatory and industrial applications, including carbon storage [2-8]. Emerging projects utilize flux stations to continuously monitor large areas before and after the injections, to locate and quantify leakages from the subsurface, to improve storage efficiency, and for other storage characterizations [5-8]. In this presentation, the latest regulatory and methodological updates are provided regarding atmospheric monitoring of the injected CO2 behavior using flux stations. These include 2013 improvements in methodology, as well as the latest literature, including regulatory documents for using the method and step-by-step instructions on implementing it in the field. Updates also include 2013 development of a fully automated remote unattended flux station capable of processing data on-the-go to continuously output final CO2 emission rates in a similar manner as a standard weather station outputs weather parameters. References: [1] Burba G. Eddy Covariance Method for Scientific, Industrial, Agricultural and Regulatory Applications. LI-COR Biosciences; 2013. [2] International Energy Agency. Quantification techniques for CO2 leakage. IEA-GHG; 2012. [3] US Department of Energy. Best Practices for Monitoring, Verification, and Accounting of CO2 Stored in Deep Geologic Formations. US DOE; 2012. [4] Liu G. (Ed.). Greenhouse Gases: Capturing, Utilization and Reduction. Intech; 2012. [5] Finley R. et al. An Assessment of Geological Carbon Sequestration Options in the Illinois Basin - Phase III. DOE-MGSC; DE-FC26-05NT42588; 2012. [6] LI-COR Biosciences. Surface Monitoring for Geologic Carbon Sequestration. LI-COR, 980-11916, 2011. [7] Eggleston H., et al. (Eds). IPCC Guidelines for National Greenhouse Gas Inventories, IPCC NGGI P, WMO/UNEP; 2006-2011. [8] Burba G., Madsen R., Feese K. Eddy Covariance Method for CO2 Emission Measurements in CCUS Applications: Principles, Instrumentation and Software. Energy Procedia, 40C: 329-336; 2013.
Uemura, Mei; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C.; Takei, Yoshiyuki
2017-01-01
Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Methods Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. Results A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. Conclusion We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. PMID:28868824
Uemura, Mei; Yano, Yutaka; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C; Takei, Yoshiyuki
2017-08-01
Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. Copyright © 2017 Korean Diabetes Association
Design and development of a compact lidar/DIAL system for aerial surveillance of urban areas
NASA Astrophysics Data System (ADS)
Gaudio, P.; Gelfusa, M.; Malizia, A.; Richetta, M.; Antonucci, A.; Ventura, P.; Murari, A.; Vega, J.
2013-10-01
Recently surveying large areas in an automatic way, for early detection of harmful chemical agents, has become a strategic objective of defence and public health organisations. The Lidar-Dial techniques are widely recognized as a cost-effective alternative to monitor large portions of the atmosphere but, up to now, they have been mainly deployed as ground based stations. The design reported in this paper concerns the development of a Lidar-Dial system compact enough to be carried by a small airplane and capable of detecting sudden releases in air of harmful and/or polluting substances. The proposed approach consists of continuous monitoring of the area under surveillance with a Lidar type measurement. Once a significant increase in the density of backscattering substances is revealed, it is intended to switch to the Dial technique to identify the released chemicals and to determine its concentration. In this paper, the design of the proposed system is described and the simulations carried out to determine its performances are reported. For the Lidar measurements, commercially available Nd- YAG laser sources have already been tested and their performances, in combination with avalanche photodiodes, have been experimentally verified to meet the required specifications. With regard to the DIAL measurements, new compact CO2 laser sources are being investigated. The most promising candidate presents an energy per pulse of about 50 mJ typical, sufficient for a range of at least 500m. The laser also provides the so called "agile tuning" option that allows to quickly tune the wavelength. To guarantee continuous, automatic surveying of large areas, innovative solutions are required for the data acquisition, self monitoring of the system and data analysis. The results of the design, the simulations and some preliminary tests illustrate the potential of the chosen, integrated approach.
Robust satellite techniques for oil spill detection and monitoring
NASA Astrophysics Data System (ADS)
Casciello, D.; Pergola, N.; Tramutoli, V.
Discharge of oil into the sea is one of the most dangerous, among technological hazards, for the maritime environment. In the last years maritime transport and exploitation of marine resources continued to increase; as a result, tanker accidents are nowadays increasingly frequent, continuously menacing the maritime security and safety. Satellite remote sensing could contribute in multiple ways, in particular for what concerns early warning and real-time (or near real-time) monitoring. Several satellite techniques exist, mainly based on the use of SAR (Synthetic Aperture Radar) technology, which are able to recognise, with sufficient accuracy, oil spills discharged into the sea. Unfortunately, such methods cannot be profitably used for real-time detection, because of the low observational frequency assured by present satellite platforms carrying SAR sensors (the mean repetition rate is something like 30 days). On the other hand, potential of optical sensors aboard meteorological satellites, was not yet fully exploited and no reliable techniques have been developed until now for this purpose. Main limit of proposed techniques can be found in the ``fixed threshold'' approach which makes such techniques difficult to implement without operator supervision and, generally, without an independent information on the oil spill presence that could drive the choice of the best threshold. A different methodological approach (RAT, Robust AVHRR Techniques) proposed by Tramutoli (1998) and already successfully applied to several natural and environmental emergencies related to volcanic eruptions, forest fires and seismic activity. In this paper its extension to near real-time detection and monitoring of oil spills by means of NOAA-AVHRR (Advanced Very High Resolution Radiometer) records will be described. Briefly, RAT approach is an automatic change-detection scheme that considers a satellite image as a space-time process, described at each place (x,y) and time t, by the value of the satellite derived measurements V(x,y,t). Generally speaking an Absolute Local Index of Change of the Environment (ALICE) is computed and this index permits to identify signal anomalies, in the space-time domain, as deviations from a normal state preliminarily defined, for each image pixel, (e.g. in terms of time average and standard deviation) on the base only of satellite observations collected during several year in the past, in similar observational conditions (same time of the day, same month of the year). By this way local (i.e. specific for the place and the time of observation) instead than fixed thresholds are automatically set by RAT which permit to discriminate signal anomalies from those variations due to natural or observational condition variability. Using AVHRR observations in the Thermal (TIR) and Middle (MIR) Infrared region, such an approach has been applied to the extended oil spill event, occurred at the end of January 1991 in the Persian Gulf. Preliminary results will be analysed that confirm as the suggested technique is able to detect and monitoring oil spills also in the most difficult observational conditions. Automatic implementation, intrinsic exportability on whatever geographic zone and/or satellite package, high sensitivity also to low intensity signals (i.e. small or thin spills), no need for ancillary information (different form satellite data at hand), seem the most promising merits of the proposed technique. Although these results should be confirmed by further analyses on different events and extended also to other AVHRR spectral bands (VIS, NIR), this work surely encourages to continue the research in this field. Moreover, the complete independence of the RAT approach on the specific sensor and/or satellite system, will ensure its full exportability on the new generation of Earth observation satellite sensors (e.g. SEVIRI-Spinning Enhanced Visible and Infrared Imager onboard Meteosat Second generation satellite, with a repetition rate of 15 minutes and 12 spectral bands) which, thanks to their improved capabilities, could actually guarantee timely, reliable and accurate information.
In situ monitoring of the integrity of bonded repair patches on aircraft and civil infrastructures
NASA Astrophysics Data System (ADS)
Kumar, Amrita; Roach, Dennis; Beard, Shawn; Qing, Xinlin; Hannum, Robert
2006-03-01
Monitoring the continued health of aircraft subsystems and identifying problems before they affect airworthiness has been a long-term goal of the aviation industry. Because in-service conditions and failure modes experienced by structures are generally complex and unknown, conservative calendar-based or usage-based scheduled maintenance practices are overly time-consuming, labor-intensive and expensive. Metal structures such as helicopters and other transportation systems are likely to develop fatigue cracks under cyclic loads and corrosive service environments. Early detection of cracks is a key element to prevent catastrophic failure and prolong structural life. Furthermore, as structures age, maintenance service frequency and costs increase while performance and availability decrease. Current non-destructive inspection (NDI) techniques that can potentially be used for this purpose typically involve complex, time-intensive procedures, which are labor-intensive and expensive. Most techniques require access to the damaged area on at least one side, and sometimes on both sides. This can be very difficult for monitoring of certain inaccessible regions. In those cases, inspection may require removal of access panels or even structural disassembly. Once access has been obtained, automated inspection techniques likely will not be practical due to the bulk of the required equipment. Results obtained from these techniques may also be sensitive to the sweep speed, tool orientation, and downward pressure. This can be especially problematic for hand-held inspection tools where none of these parameters is mechanically controlled. As a result, data can vary drastically from one inspection to the next, from one technician to the next, and even from one sweep to the next. Structural health monitoring (SHM) offers the promise of a paradigm shift from schedule-driven maintenance to condition-based maintenance (CBM) of assets. Sensors embedded permanently in aircraft safety critical structures that can monitor damage can provide for improved reliability and streamlining of aircraft maintenance. Early detection of damage such as fatigue crack initiation can improve personnel safety and prolong service life. This paper presents the testing of an acousto-ultrasonic piezoelectric sensor based structural health monitoring system for real-time monitoring of fatigue cracks and disbonds in bonded repairs. The system utilizes a network of distributed miniature piezoelectric sensors/actuators embedded on a thin dielectric carrier film, to query, monitor and evaluate the condition of a structure. The sensor layers are extremely flexible and can be integrated with any type of metal or composite structure. Diagnostic signals obtained from a structure during structural monitoring are processed by a portable diagnostic unit. With appropriate diagnostic software, the signals can be analyzed to ascertain the integrity of the structure being monitored. Details on the system, its integration and examples of detection of fatigue crack and disbond growth and quantification for bonded repairs will be presented here.
NASA Astrophysics Data System (ADS)
Hürlimann, Marcel; Abancó, Clàudia; Moya, José; Vilajosana, Ignasi; Llosa, Jordi
2013-04-01
Sophisticated monitoring of landslides for research purpose has started in the 1990thies in the Catalan Pyrenees. Since then several types of mass movements (large landslides, debris flows, shallow landslides and rock falls) and multiples techniques have been applied. In this contribution, special attention will be given to the debris-flow monitoring system installed since summer 2009 in the Rebaixader catchment, Central Pyrenees. The monitoring system has continuously been improved during the last years and nowadays includes devices studying the three major aspects: 1) initiation, 2) flow dynamics, and 3) accumulation. While some parts of the monitoring network include a traditional wired system, the newer parts were installed using low-power wireless devices. Two major aspects will be discussed. First, results of the Rebaixader monitoring site will be presented. Second, experience regarding the monitoring will be evaluated focussing on technical aspects and the comparison between wired and wireless techniques. In the Rebaixader catchment, 6 debris flows and 11 debris floods were observed between August 2009 and October 2012. Surprisingly, also 4 major rock falls were recorded. The rainfall analysis shows that the debris flows were triggered by short, high-intensity rainstorms with a preliminary threshold of about 15 mm during 1 hour. In addition, there was observed a positive trend between event volume and rainfall amount or intensity. The analysis of the ground vibration signals shows significant differences between the time series recorded at the different geophones. These differences are associated with the geophone location in the channel (distance and material), the mounting or the data acquisition system. For instance, the most downstream geophone, installed in bedrock, shows the clearest debris-flows vibration time series, while the uppermost is the most reliable regarding the detection of rockfalls. An evaluation of wired versus wireless monitoring systems shows that wireless techniques have several advantages. They are generally smaller and due to the wireless condition the selection of the sensor location is not restricted like in the standard wired systems. Additionally, they are simple to install and consume much less power. Importantly, they are also more competitive in terms of pricing versus traditional wired solutions. Nevertheless, the adoption of this new technology has not been straightforward due to the harsh conditions where sensors are usually deployed. The later delayed and complicated the installation of some sensors in the Rebaixader site but allowed us to improve the monitoring solution. Finally, some very recent experiences on the wireless sensor network installed in a shallow landslide in the Pre-Pyrenees confirmed that this technique is a perfect solution not only for monitoring, but also for warning systems.
Monitoring Wetlands Area Using Microwave, Optical And In-Situ Data
NASA Astrophysics Data System (ADS)
Dabrowska, Katarzyna; Zielinska, Maria Budzynska
2011-01-01
The study of Wetlands has been continue within the PECS Project: “Study and implement remote sensing techniques for the assessment of carbon balances for different biomasses and soil moistures within various ecosystems”. The research has been conducted in Biebrza valley, one of the largest wetland in Europe, since 2003. Recently, to existing data base of wetlands monitoring Carbon flux measurements using the Chamber Method and Eddy Correlation Method have been included. The study aims at monitoring and mapping various soil-vegetation variables and the assessment of the level of carbon balance using optical and microwave satellite data along with ground truth observations. Optical images have been used for classification of wetlands vegetation and calculation of LAI and biomass. For the assessment of water balance, energy budget approach has been applied. Microwave images have been used for the assessment of soil moisture and biomass.
Review of Trackside Monitoring Solutions: From Strain Gages to Optical Fibre Sensors
Kouroussis, Georges; Caucheteur, Christophe; Kinet, Damien; Alexandrou, Georgios; Verlinden, Olivier; Moeyaert, Véronique
2015-01-01
A review of recent research on structural monitoring in railway industry is proposed in this paper, with a special focus on stress-based solutions. After a brief analysis of the mechanical behaviour of ballasted railway tracks, an overview of the most common monitoring techniques is presented. A special attention is paid on strain gages and accelerometers for which the accurate mounting position on the track is requisite. These types of solution are then compared to another modern approach based on the use of optical fibres. Besides, an in-depth discussion is made on the evolution of numerical models that investigate the interaction between railway vehicles and tracks. These models are used to validate experimental devices and to predict the best location(s) of the sensors. It is hoped that this review article will stimulate further research activities in this continuously expanding field. PMID:26287207
An IMS Station life cycle from a sustainment point of view
NASA Astrophysics Data System (ADS)
Brely, Natalie; Gautier, Jean-Pierre; Foster, Daniel
2014-05-01
The International Monitoring System (IMS) is to consist of 321 monitoring facilities, composed of four different technologies with a variety of designs and equipment types, deployed in a range of environments around the globe. The International Monitoring System is conceived to operate in perpetuity through maintenance, replacement and recapitalization of IMS facilities' infrastructure and equipment when the end of service life is reached [CTBT/PTS/INF.1163]. Life Cycle techniques and modellization are being used by the PTS to plan and forecast life cycle sustainment requirements of IMS facilities. Through historical data analysis, Engineering inputs and Feedback from experienced Station Operators, the PTS currently works towards increasing the level of confidence on these forecasts and sustainment requirements planning. Continued validation, feedback and improvement of source data from scientific community and experienced users is sought and essential in order to ensure limited effect on data availability and optimal costs (human and financial).
Kussman, Barry D; Wypij, David; DiNardo, James A; Newburger, Jane; Jonas, Richard A; Bartlett, Jodi; McGrath, Ellen; Laussen, Peter C
2005-11-01
Cerebral oximetry is a technique that enables monitoring of regional cerebral oxygenation during cardiac surgery. In this study, we evaluated differences in bi-hemispheric measurement of cerebral oxygen saturation using near-infrared spectroscopy in 62 infants undergoing biventricular repair without aortic arch reconstruction. Left and right regional cerebral oxygen saturation index (rSO2i) were recorded continuously after the induction of anesthesia, and data were analyzed at 12 time points. Baseline rSO2i measurements were left 65 +/- 13 and right 66 +/- 13 (P = 0.17). Mean left and right rSO2i measurements were similar (< or =2 percentage points/absolute scale units) before, during, and after cardiopulmonary bypass, irrespective of the use of deep hypothermic circulatory arrest. Further longitudinal neurological outcome studies are required to determine whether uni- or bi-hemispheric monitoring is required in this patient population.
Single-station monitoring of volcanoes using seismic ambient noise
NASA Astrophysics Data System (ADS)
De Plaen, Raphael S. M.; Lecocq, Thomas; Caudron, Corentin; Ferrazzini, Valérie; Francis, Olivier
2016-08-01
Seismic ambient noise cross correlation is increasingly used to monitor volcanic activity. However, this method is usually limited to volcanoes equipped with large and dense networks of broadband stations. The single-station approach may provide a powerful and reliable alternative to the classical "cross-station" approach when measuring variation of seismic velocities. We implemented it on the Piton de la Fournaise in Reunion Island, a very active volcano with a remarkable multidisciplinary continuous monitoring. Over the past decade, this volcano has been increasingly studied using the traditional cross-correlation technique and therefore represents a unique laboratory to validate our approach. Our results, tested on stations located up to 3.5 km from the eruptive site, performed as well as the classical approach to detect the volcanic eruption in the 1-2 Hz frequency band. This opens new perspectives to successfully forecast volcanic activity at volcanoes equipped with a single three-component seismometer.
Borycki, Dawid; Kholiqov, Oybek; Srinivasan, Vivek J
2017-02-01
Interferometric near-infrared spectroscopy (iNIRS) is a new technique that measures time-of-flight- (TOF-) resolved autocorrelations in turbid media, enabling simultaneous estimation of optical and dynamical properties. Here, we demonstrate reflectance-mode iNIRS for noninvasive monitoring of a mouse brain in vivo. A method for more precise quantification with less static interference from superficial layers, based on separating static and dynamic components of the optical field autocorrelation, is presented. Absolute values of absorption, reduced scattering, and blood flow index (BFI) are measured, and changes in BFI and absorption are monitored during a hypercapnic challenge. Absorption changes from TOF-resolved iNIRS agree with absorption changes from continuous wave NIRS analysis, based on TOF-integrated light intensity changes, an effective path length, and the modified Beer-Lambert Law. Thus, iNIRS is a promising approach for quantitative and noninvasive monitoring of perfusion and optical properties in vivo.
Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals
Peng, Rong-Chao; Yan, Wen-Rong; Zhang, Ning-Ling; Lin, Wan-Hua; Zhou, Xiao-Lin; Zhang, Yuan-Ting
2015-01-01
Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services. PMID:26393591
Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals.
Peng, Rong-Chao; Yan, Wen-Rong; Zhang, Ning-Ling; Lin, Wan-Hua; Zhou, Xiao-Lin; Zhang, Yuan-Ting
2015-09-17
Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.
Le Saux, Thomas; Hisamoto, Hideaki; Terabe, Shigeru
2006-02-03
Measurement of binding constant by chip electrophoresis is a very promising technique for the high throughput screening of non-covalent interactions. Among the different electrophoretic methods available that yield the binding parameters, continuous frontal analysis is the most appropriate for a transposition from capillary electrophoresis (CE) to microchip electrophoresis. Implementation of this methodology in microchip was exemplified by the measurement of inclusion constants of 2-naphtalenesulfonate and neutral phenols (phenol, 4-chlorophenol and 4-nitrophenol) into beta-cyclodextrin by competitive assays. The issue of competitor choice is discussed in relation to its appropriateness for proper monitoring of the interaction.
Reduction of operations and maintenance costs at geothermal power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruton, C.J.; Stevens, C.G.; Rard, J.A.
1997-12-31
To reduce chemical costs at geothermal power plants, we are investigating: (a) improved chemical processes associated with H{sub 2}S abatement techniques, and (b) the use of cross dispersive infrared spectrometry to monitor accurately, reliably, and continuously H{sub 2}S emissions from cooling towers. The latter is a new type of infrared optical technology developed by LLNL for non-proliferation verification. Initial work is focused at The Geysers in cooperation with Pacific Gas and Electric. Methods for deploying the spectrometer on-site at The Geysers are being developed. Chemical analysis of solutions involved in H{sub 2}S abatement technologies is continuing to isolate the chemicalmore » forms of sulfur produced.« less
Nanosensor system for monitoring brain activity and drowsiness
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Varadan, Vijay K.; Harbaugh, Robert
2015-04-01
Detection of drowsiness in drivers to avoid on-road collisions and accidents is one of the most important applications that can be implemented to avert loss of life and property caused by accidents. A statistical report indicates that drowsy driving is equally harmful as driving under influence of alcohol. This report also indicates that drowsy driving is the third most influencing factor for accidents and 30% of the commercial vehicle accidents are caused because of drowsy driving. With a motivation to avoid accidents caused by drowsy driving, this paper proposes a technique of correlating EEG and EOG signals to detect drowsiness. Feature extracts of EEG and blink variability from EOG is correlated to detect the sleepiness/drowsiness of a driver. Moreover, to implement a more pragmatic approach towards continuous monitoring, a wireless real time monitoring approach has been incorporated using textile based nanosensors. Thereby, acquired bio potential signals are transmitted through GSM communication module to the receiver continuously. In addition to this, all the incorporated electronics are equipped in a flexible headband which can be worn by the driver. With this flexible headband approach, any intrusiveness that may be experienced by other cumbersome hardware is effectively mitigated. With the continuous transmission of data from the head band, the signals are processed on the receiver side to determine the condition of the driver. Early warning of driver's drowsiness will be displayed in the dashboard of the vehicle as well as alertness voice and sound alarm will be sent via the vehicle radio.
Nerve sparing sutureless total thyroidectomy. Preliminary study.
Parmeggiani, Domenico; De Falco, Massimo; Avenia, Nicola; Sanguinetti, Alessandro; Fiore, Andrea; Docimo, Giovanni; Ambrosino, Pasquale; Madonna, Imma; Peltrini, Roberto; Parmeggiani, Umberto
2012-01-01
In the present study the authors assess the advantages of new technologies in thyroid surgery: to prevent nerve injury by using an intra-operative continuous nerve-monitoring techniques and to compare the real advantages of advanced coagulation devices. Among a series of 440 thyroidectomies (jan 2004-feb 2006) the Authors reviewed charts from two groups: (1) 240 total thyroidectomies performed using the traditional monopolar electrocautery, non-absorbable stitches for the principal vascular pedicles. (2) 140 total thyroidectomies performed using dedicated small bipolar electro thermal coagulator (ligasure-precise). (3) Since 2006 in a double blind group selection of 70, we've performed sutureless thyroidectomy with continuous intraoperative nerve monitoring using dedicated endotracheal tube. Mean operative time, post-operative bleeding, post-operative stay, incidence of transient or definitive laryngeal nerve lesions, incidence of permanent or transient hypocalcaemia, costs of the procedures were analyzed. Major complications in the first two groups compared with the data of the literature are absolutely over-imposable, except a reduction of incidence of transient hypocalcaemia in the Precise group, but if we compare data of the 3rd group (NIM), we find a significative reduction of transient and permanent laryngeal nerve palsy incidence. This new technology offers several advantages: (1) atraumatic; (2) easy to use; (3) continuous monitoring and audio feedback to the surgeon (4) works outside the operation field (5) high sensitiveness. Cost-analysis confirm that NIM + ligasure have same or less cost and time and probably less complications than traditional Total Thyroidectomy.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
... 1219-AB64 Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust... to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. This extension gives... Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. In response...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2014 CFR
2014-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2013 CFR
2013-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Real-time surveillance system for marine environment based on HLIF LiDAR
NASA Astrophysics Data System (ADS)
Babichenko, Sergey; Sobolev, Innokenti; Aleksejev, Valeri; Sõro, Oliver
2017-10-01
The operational monitoring of the risk areas of marine environment requires cost-effective solutions. One of the options is the use of sensor networks based on fixed installations and moving platforms (coastal boats, supply-, cargo-, and passenger vessels). Such network allows to gather environmental data in time and space with direct links to operational activities in the controlled area for further environmental risk assessment. Among many remote sensing techniques the LiDAR (Light Detection And Ranging) based on Light Induced Fluorescence (LIF) is the tool of direct assessment of water quality variations caused by chemical pollution, colored dissolved organic matter, and phytoplankton composition. The Hyperspectral LIF (HLIF) LiDAR acquires comprehensive LIF spectra and analyses them by spectral pattern recognition technique to detect and classify the substances in water remotely. Combined use of HLIF LiDARs with Real-Time Data Management System (RTDMS) provides the economically effective solution for the regular monitoring in the controlled area. OCEAN VISUALS in cooperation with LDI INNOVATION has developed Oil in Water Locator (OWL™) with RTDMS (OWL MAP™) based on HLIF LiDAR technique. This is a novel technical solution for monitoring of marine environment providing continuous unattended operations. OWL™ has been extensively tested on board of various vessels in the North Sea, Norwegian Sea, Barents Sea, Baltic Sea and Caribbean Sea. This paper describes the technology features, the results of its operational use in 2014-2017, and outlook for the technology development.
Thelin, Eric Peter; Carpenter, Keri L H; Hutchinson, Peter J; Helmy, Adel
2017-03-01
Injuries to the central nervous system continue to be vast contributors to morbidity and mortality; specifically, traumatic brain injury (TBI) is the most common cause of death during the first four decades of life. Several modalities are used to monitor patients suffering from TBI in order to prevent detrimental secondary injuries. The microdialysis (MD) technique, introduced during the 1990s, presents the treating physician with a robust monitoring tool for brain chemistry in addition to conventional intracranial pressure monitoring. Nevertheless, some limitations remain, such as limited spatial resolution. Moreover, while there have been several attempts to develop new potential pharmacological therapies in TBI, there are currently no available drugs which have shown clinical efficacy that targets the underlying pathophysiology, despite various trials investigating a plethora of pharmaceuticals. Specifically in the brain, MD is able to demonstrate penetration of the drug through the blood-brain barrier into the brain extracellular space at potential site of action. In addition, the downstream effects of drug action can be monitored directly. In the future, clinical MD, together with other monitoring modalities, can identify specific pathological substrates which require tailored treatment strategies for patients suffering from TBI.
Supramolecular Systems and Chemical Reactions in Single-Molecule Break Junctions.
Li, Xiaohui; Hu, Duan; Tan, Zhibing; Bai, Jie; Xiao, Zongyuan; Yang, Yang; Shi, Jia; Hong, Wenjing
2017-04-01
The major challenges of molecular electronics are the understanding and manipulation of the electron transport through the single-molecule junction. With the single-molecule break junction techniques, including scanning tunneling microscope break junction technique and mechanically controllable break junction technique, the charge transport through various single-molecule and supramolecular junctions has been studied during the dynamic fabrication and continuous characterization of molecular junctions. This review starts from the charge transport characterization of supramolecular junctions through a variety of noncovalent interactions, such as hydrogen bond, π-π interaction, and electrostatic force. We further review the recent progress in constructing highly conductive molecular junctions via chemical reactions, the response of molecular junctions to external stimuli, as well as the application of break junction techniques in controlling and monitoring chemical reactions in situ. We suggest that beyond the measurement of single molecular conductance, the single-molecule break junction techniques provide a promising access to study molecular assembly and chemical reactions at the single-molecule scale.
NASA Astrophysics Data System (ADS)
Mulas, Marco; Corsini, Alessandro; Soldati, Mauro; Marcato, Gianluca; Pasuto, Alessandro; Crespi, Mattia; Mazzoni, Augusto; Benedetti, Elisa; Branzanti, Mara; Manunta, Michele; Ojha, Chandrakanta; Chinellato, Giulia; Cuozzo, Giovanni; Costa, Armin; Monsorno, Roberto; Thiebes, Benni; Piantelli, Elena; Magnani, Massimo; Meroni, Marco; Mair, Volkmar
2015-04-01
The Corvara landslide is an active, large-scale, deep-seated and slow moving earthslide of about 30 Mm3 located in the Dolomites (Italy). It is frequently damaging a national road and, occasionally, isolated buildings and recreational ski facilities. Since the mid '90s it has been mapped, dated and monitored thanks to field surveys, boreholes, radiocarbon dating, inclinometers, piezometers and periodic D-GPS measurements, carried out by the Geology and the Forestry Planning offices of the Autonomous Province of Bolzano, the Municipality of Corvara in Badia, the University of Modena and Reggio Emilia, the IRPI-CNR of Padua. In 2013, a new phase of characterization and monitoring has started which also involves the EURAC's Institute for Applied Remote Sensing, the geodesy group of University La Sapienza, the CNR-IREA of Naples and the Leica Geosystems office in Italy. This new phase of characterization and monitoring is meant to investigate the opportunities of innovative SAR interferometry, D-GPS and in-place inclinometers techniques to provide for a high frequency monitoring of the study site in support to the analysis of the investigation of forcing factors leading unsteady, nonuniform landslide motion through different seasons of the year. Monitoring results are also expected to provide a validation of innovative interferometric techniques so to fully evaluate their conformity to be used as a long-term monitoring system in land-use planning and risk management procedures. The monitoring infrastructure now integrates: 16 Corner Reflector for satellite X-Band SAR interferometric products, 13 benchmarks for D-GPS periodic surveys, three on-site GPS receivers for continuous positioning and remote ftp data pushing, two in-place inclinometers and a pressure transducer to record pore-pressure variations. The coupling of SAR-based products with GPS records is achieved using especially designed Corner Reflectors having an appendix dedicated to hold Dual-Frequency GPS antennas. COSMO-SkyMed X-Band SAR acquisitions started on October 2013 and are ongoing with a temporal resolution of 16 days using STRIPMAP (HIMAGE) measuring mode. Discontinuous D-GPS Fast-Static surveys are scheduled with a triple frequency: annual for 24 points outside recent activation areas, monthly for 13 points in the active zone and a bi-weekly for 6 points located in the most active zone. Displacement high-frequency data are acquired thank to the installation of 3 Dual-Frequency GPS in permanent acquisition that have been located in the accumulation, track and source zone of the active portion of the landslide. High frequency data are also obtained by the two inclinometers operating in continuous acquisition located across the main slide surface at 48 m depth into a 90 m borehole drilled in the accumulation zone. A piezometer installed in the source zone and the meteorological station of Piz La Ila (3 km far away) of the Autonomous Province of Bolzano complete the system. The poster presents the infrastructural details of the monitoring network, the technical characteristics of data acquisition systems, the data processing procedures and the latest ongoing results.
Monitoring Knowledge Base (MKB)
The Monitoring Knowledge Base (MKB) is a compilation of emissions measurement and monitoring techniques associated with air pollution control devices, industrial process descriptions, and permitting techniques, including flexible permit development. Using MKB, one can gain a comprehensive understanding of emissions sources, control devices, and monitoring techniques, enabling one to determine appropriate permit terms and conditions.
Methods and techniques for measuring gas emissions from agricultural and animal feeding operations.
Hu, Enzhu; Babcock, Esther L; Bialkowski, Stephen E; Jones, Scott B; Tuller, Markus
2014-01-01
Emissions of gases from agricultural and animal feeding operations contribute to climate change, produce odors, degrade sensitive ecosystems, and pose a threat to public health. The complexity of processes and environmental variables affecting these emissions complicate accurate and reliable quantification of gas fluxes and production rates. Although a plethora of measurement technologies exist, each method has its limitations that exacerbate accurate quantification of gas fluxes. Despite a growing interest in gas emission measurements, only a few available technologies include real-time, continuous monitoring capabilities. Commonly applied state-of-the-art measurement frameworks and technologies were critically examined and discussed, and recommendations for future research to address real-time monitoring requirements for forthcoming regulation and management needs are provided.
Kennedy, M M
1998-01-01
Can anyone single-handedly create a caring environment without adding hours to his or her work week? As turnover continues to rise, it's worth considering. Techniques managers say have worked for them are suggested, including: Monitor workloads; celebrate successes; make niceness an expectation; mentor; offer training as often as possible; stamp out problems before they go public; consider offering flexible hours and extended leaves for all; and introduce yeast to keep people stimulated. Will these strategies--all of which may not work for you--fatten your bonus this year? Probably not, unless top management is monitoring retention and doing occasional exit interviews. However, one of the byproducts is that employees don't stop with each other. They begin to treat patients better, something neither bribery nor threats may produce.
NASA Technical Reports Server (NTRS)
Griffin, Timothy P.; Naylor, Guy R.; Hritz, Richard J.; Barrett, Carolyn A.
1997-01-01
The main engines of the Space Shuttle use hydrogen and oxygen as the fuel and oxidant. The explosive and fire hazards associated with these two components pose a serious danger to personnel and equipment. Therefore prior to use the main engines undergo extensive leak tests. Instead of using hazardous gases there tests utilize helium as the tracer element. This results in a need to monitor helium in the ppm level continuously for hours. The major challenge in developing such a low level gas monitor is the sample delivery system. This paper discuss a system developed to meet the requirements while also being mobile. Also shown is the calibration technique, stability, and accuracy results for the system.
NASA Technical Reports Server (NTRS)
Narasimhan, Sriram; Dearden, Richard; Benazera, Emmanuel
2004-01-01
Fault detection and isolation are critical tasks to ensure correct operation of systems. When we consider stochastic hybrid systems, diagnosis algorithms need to track both the discrete mode and the continuous state of the system in the presence of noise. Deterministic techniques like Livingstone cannot deal with the stochasticity in the system and models. Conversely Bayesian belief update techniques such as particle filters may require many computational resources to get a good approximation of the true belief state. In this paper we propose a fault detection and isolation architecture for stochastic hybrid systems that combines look-ahead Rao-Blackwellized Particle Filters (RBPF) with the Livingstone 3 (L3) diagnosis engine. In this approach RBPF is used to track the nominal behavior, a novel n-step prediction scheme is used for fault detection and L3 is used to generate a set of candidates that are consistent with the discrepant observations which then continue to be tracked by the RBPF scheme.
Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.
Moy, Foong Ming; Ray, Amita; Buckley, Brian S; West, Helen M
2017-06-11
Self-monitoring of blood glucose (SMBG) is recommended as a key component of the management plan for diabetes therapy during pregnancy. No existing systematic reviews consider the benefits/effectiveness of various techniques of blood glucose monitoring on maternal and infant outcomes among pregnant women with pre-existing diabetes. The effectiveness of the various monitoring techniques is unclear. To compare techniques of blood glucose monitoring and their impact on maternal and infant outcomes among pregnant women with pre-existing diabetes. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016), searched reference lists of retrieved studies and contacted trial authors. Randomised controlled trials (RCTs) and quasi-RCTs comparing techniques of blood glucose monitoring including SMBG, continuous glucose monitoring (CGM) or clinic monitoring among pregnant women with pre-existing diabetes mellitus (type 1 or type 2). Trials investigating timing and frequency of monitoring were also included. RCTs using a cluster-randomised design were eligible for inclusion but none were identified. Two review authors independently assessed study eligibility, extracted data and assessed the risk of bias of included studies. Data were checked for accuracy. The quality of the evidence was assessed using the GRADE approach. This review update includes at total of 10 trials (538) women (468 women with type 1 diabetes and 70 women with type 2 diabetes). The trials took place in Europe and the USA. Five of the 10 included studies were at moderate risk of bias, four studies were at low to moderate risk of bias, and one study was at high risk of bias. The trials are too small to show differences in important outcomes such as macrosomia, preterm birth, miscarriage or death of baby. Almost all the reported GRADE outcomes were assessed as being very low-quality evidence. This was due to design limitations in the studies, wide confidence intervals, small sample sizes, and few events. In addition, there was high heterogeneity for some outcomes.Various methods of glucose monitoring were compared in the trials. Neither pooled analyses nor individual trial analyses showed any clear advantages of one monitoring technique over another for primary and secondary outcomes. Many important outcomes were not reported.1. Self-monitoring versus standard care (two studies, 43 women): there was no clear difference for caesarean section (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.40 to 1.49; one study, 28 women) or glycaemic control (both very low-quality), and not enough evidence to assess perinatal mortality and neonatal mortality and morbidity composite. Hypertensive disorders of pregnancy, large-for-gestational age, neurosensory disability, and preterm birth were not reported in either study.2. Self-monitoring versus hospitalisation (one study, 100 women): there was no clear difference for hypertensive disorders of pregnancy (pre-eclampsia and hypertension) (RR 4.26, 95% CI 0.52 to 35.16; very low-quality: RR 0.43, 95% CI 0.08 to 2.22; very low-quality). There was no clear difference in caesarean section or preterm birth less than 37 weeks' gestation (both very low quality), and the sample size was too small to assess perinatal mortality (very low-quality). Large-for-gestational age, mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.3. Pre-prandial versus post-prandial glucose monitoring (one study, 61 women): there was no clear difference between groups for caesarean section (RR 1.45, 95% CI 0.92 to 2.28; very low-quality), large-for-gestational age (RR 1.16, 95% CI 0.73 to 1.85; very low-quality) or glycaemic control (very low-quality). The results for hypertensive disorders of pregnancy: pre-eclampsia and perinatal mortality are not meaningful because these outcomes were too rare to show differences in a small sample (all very low-quality). The study did not report the outcomes mortality or morbidity composite, neurosensory disability or preterm birth.4. Automated telemedicine monitoring versus conventional system (three studies, 84 women): there was no clear difference for caesarean section (RR 0.96, 95% CI 0.62 to 1.48; one study, 32 women; very low-quality), and mortality or morbidity composite in the one study that reported these outcomes. There were no clear differences for glycaemic control (very low-quality). No studies reported hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), neurosensory disability or preterm birth.5.CGM versus intermittent monitoring (two studies, 225 women): there was no clear difference for pre-eclampsia (RR 1.37, 95% CI 0.52 to 3.59; low-quality), caesarean section (average RR 1.00, 95% CI 0.65 to 1.54; I² = 62%; very low-quality) and large-for-gestational age (average RR 0.89, 95% CI 0.41 to 1.92; I² = 82%; very low-quality). Glycaemic control indicated by mean maternal HbA1c was lower for women in the continuous monitoring group (mean difference (MD) -0.60 %, 95% CI -0.91 to -0.29; one study, 71 women; moderate-quality). There was not enough evidence to assess perinatal mortality and there were no clear differences for preterm birth less than 37 weeks' gestation (low-quality). Mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.6. Constant CGM versus intermittent CGM (one study, 25 women): there was no clear difference between groups for caesarean section (RR 0.77, 95% CI 0.33 to 1.79; very low-quality), glycaemic control (mean blood glucose in the 3rd trimester) (MD -0.14 mmol/L, 95% CI -2.00 to 1.72; very low-quality) or preterm birth less than 37 weeks' gestation (RR 1.08, 95% CI 0.08 to 15.46; very low-quality). Other primary (hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), mortality or morbidity composite, and neurosensory disability) or GRADE outcomes (preterm birth less than 34 weeks' gestation) were not reported. This review found no evidence that any glucose monitoring technique is superior to any other technique among pregnant women with pre-existing type 1 or type 2 diabetes. The evidence base for the effectiveness of monitoring techniques is weak and additional evidence from large well-designed randomised trials is required to inform choices of glucose monitoring techniques.
Continuous monitoring of kidney transplant perfusion with near-infrared spectroscopy.
Malakasioti, Georgia; Marks, Stephen D; Watson, Tom; Williams, Fariba; Taylor-Allkins, Mariesa; Mamode, Nizam; Morgan, Justin; Hayes, Wesley N
2018-05-11
Current reliance on clinical, laboratory and Doppler ultrasound (DUS) parameters for monitoring kidney transplant perfusion in the immediate post-operative period in children risks late recognition of allograft hypoperfusion and vascular complications. Near-infrared spectroscopy (NIRS) is a real-time, non-invasive technique for monitoring tissue oxygenation percutaneously. NIRS monitoring of kidney transplant perfusion has not previously been validated to the gold standard of DUS. We examined whether NIRS tissue oxygenation indices can reliably assess blood flow in established paediatric kidney transplants. Paediatric kidney transplant recipients ages 1-18 years with stable allograft function were eligible. Participants underwent routine DUS assessment of kidney transplant perfusion, including resistive index (RI) and peak systolic velocity at the upper and lower poles. NIRS data [tissue oxygenation index (TOI%)] were recorded for a minimum of 2 min with NIRS sensors placed on the skin over upper and lower allograft poles. Twenty-nine subjects with a median age of 13.3 (range 4.8-17.8) years and a median transplant vintage of 26.5 months participated. Thirteen (45%) were female and 20 (69%) were living donor kidney recipients. NIRS monitoring was well tolerated by all, with 96-100% valid measurements. Significant negative correlations were observed between NIRS TOI% and DUS RI at both the upper and lower poles (r = -0.4 and -0.6, P = 0.04 and 0.001, respectively). Systolic blood pressure but not estimated glomerular filtration rate also correlated with NIRS TOI% (P = 0.01). NIRS indices correlate well with DUS perfusion and haemodynamic parameters in established paediatric kidney transplant recipients. Further studies are warranted to extend NIRS use for continuous real-time monitoring of early post-transplant perfusion status.
Code of Federal Regulations, 2012 CFR
2012-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... Combustion Units Constructed on or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1735... to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2010 CFR
2010-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... monitoring system according to § 60.13. (c) Complete an initial evaluation of your continuous opacity monitoring system according to Performance Specification 1 in appendix B of this part. Complete the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... appendix F requirements to evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... appendix F requirements to evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or...
On the potential of RST approach for a continuous monitoring of flooded areas
NASA Astrophysics Data System (ADS)
Faruolo, Mariapia; Coviello, Irina; Lacava, Teodosio; Pergola, Nicola; Tramutoli, Valerio
2010-05-01
In recent decades many efforts have been made in the field of remote sensing for the management of flood risk. In fact, among all natural disasters floods are probably the most frequent, causing high human suffering and large losses. All activities designed to mitigate and manage flood risk, in order to be effective and to help civil protection agencies in limiting losses of life, human suffering and damages, need of timely information about the onset of floods, their extent, intensity and duration. At present, sensors aboard meteorological satellites, mainly thanks to their high temporal resolution, may furnish frequent and updated images, ensuring a continuous monitoring of areas involved by a flood. In particular, optical instruments on board polar satellites, like NOAA-AVHRR (National Oceanic and Atmospheric Administration-Advanced Very High Resolution Radiometer) and more recently EOS-MODIS (Earth Observing System-Moderate Resolution Imaging Spectroradiometer) have been used for dynamic flood monitoring. A robust methodology for satellite based flood monitoring and detection, named RST (Robust Satellite Technique), has been recently developed and implemented using data acquired by AVHRR and MODIS to identify flooded areas with reliability and timeliness. Such an approach, based on a multi-temporal analysis of co-located satellite records and an automatic change detection scheme, has been used to analyze floods occurred in different geographic areas and observational conditions. In detail, in order to identify flooded areas within the region of interest, the spectral behavior of water in the visible (VIS) and near infrared (NIR) bands of such satellite systems has been successfully exploited. Starting from these satisfactory results, the main purpose of this paper is to show, in the case of several flooding events occurred recently in different parts of the world, the achievements arising from the use of such methodology also to data acquired in the thermal infrared (TIR) region in order to guarantee a continuous monitoring of flooded areas both during night and day.
Continuous positive airway pressure: Physiology and comparison of devices.
Gupta, Samir; Donn, Steven M
2016-06-01
Nasal continuous positive airway pressure (CPAP) is increasingly used for respiratory support in preterm babies at birth and after extubation from mechanical ventilation. Various CPAP devices are available for use that can be broadly grouped into continuous flow and variable flow. There are potential physiologic differences between these CPAP systems and the choice of a CPAP device is too often guided by individual expertise and experience rather than by evidence. When interpreting the evidence clinicians should take into account the pressure generation sources, nasal interface, and the factors affecting the delivery of pressure, such as mouth position and respiratory drive. With increasing use of these devices, better monitoring techniques are required to assess the efficacy and early recognition of babies who are failing and in need of escalated support. Copyright © 2016 Elsevier Ltd. All rights reserved.
40 CFR 60.1715 - What types of continuous emission monitoring must I perform?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines... must I perform? To continuously monitor emissions, you must perform four tasks: (a) Install continuous...
Spatial and Temporal Monitoring Resolutions for CO2 Leakage Detection at Carbon Storage Sites
NASA Astrophysics Data System (ADS)
Yang, Y. M.; Dilmore, R. M.; Daley, T. M.; Carroll, S.; Mansoor, K.; Gasperikova, E.; Harbert, W.; Wang, Z.; Bromhal, G. S.; Small, M.
2016-12-01
Different leakage monitoring techniques offer different strengths in detection sensitivity, coverage, feedback time, cost, and technology availability, such that they may complement each other when applied together. This research focuses on quantifying the spatial coverage and temporal resolution of detection response for several geophysical remote monitoring and direct groundwater monitoring techniques for an optimal monitoring plan for CO2 leakage detection. Various monitoring techniques with different monitoring depths are selected: 3D time-lapse seismic survey, wellbore pressure, groundwater chemistry and soil gas. The spatial resolution in terms of leakage detectability is quantified through the effective detection distance between two adjacent monitors, given the magnitude of leakage and specified detection probability. The effective detection distances are obtained either from leakage simulations with various monitoring densities or from information garnered from field test data. These spatial leakage detection resolutions are affected by physically feasible monitoring design and detection limits. Similarly, the temporal resolution, in terms of leakage detectability, is quantified through the effective time to positive detection of a given size of leak and a specified detection probability, again obtained either from representative leakage simulations with various monitoring densities or from field test data. The effective time to positive detection is also affected by operational feedback time (associated with sampling, sample analysis and data interpretation), with values obtained mainly through expert interviews and literature review. In additional to the spatial and temporal resolutions of these monitoring techniques, the impact of CO2 plume migration speed and leakage detection sensitivity of each monitoring technique are also discussed with consideration of how much monitoring is necessary for effective leakage detection and how these monitoring techniques can be better combined in a time-space framework. The results of the spatial and temporal leakage detection resolutions for several geophysical monitoring techniques and groundwater monitoring are summarized to inform future monitoring designs at carbon storage sites.
NASA Astrophysics Data System (ADS)
Galfond, B.; Riemer, D. D.; Swart, P. K.
2014-12-01
In order for Carbon Capture Utilization and Storage (CCUS) to gain wide acceptance as a method for mitigating atmospheric CO2 concentrations, schemes must be devised to ensure that potential leakage is detected. New regulations from the US Environmental Protection Agency require monitoring and accounting for Class VI injection wells, which will remain a barrier to wide scale CCUS deployment until effective and efficient monitoring techniques have been developed and proven. Monitoring near-surface CO2 at injection sites to ensure safety and operational success requires high temporal resolution CO2 concentration and carbon isotopic (δ13C) measurements. The only technologies currently capable of this rapid measurement of δ13C are optical techniques such as Cavity Ringdown Spectroscopy (CRDS). We have developed a comprehensive remote monitoring approach using CRDS and a custom manifold system to obtain accurate rapid measurements from a large sample area over an extended study period. Our modified Picarro G1101-i CRDS allows for automated rapid and continuous field measurement of δ13CO2 and concentrations of relevant gas species. At our field site, where preparations have been underway for Enhanced Oil Recovery (EOR) operations, we have been able to measure biogenic effects on a diurnal scale, as well as variation due to precipitation and seasonality. Taking these background trends into account, our statistical treatment of real data has been used to improve signal-to-noise ratios by an order of magnitude over published models. Our system has proven field readiness for the monitoring of sites with even modest CO2 fluxes.
Sarraguça, Mafalda C; Paulo, Ana; Alves, Madalena M; Dias, Ana M A; Lopes, João A; Ferreira, Eugénio C
2009-10-01
The performance of an activated sludge reactor can be significantly enhanced through use of continuous and real-time process-state monitoring, which avoids the need to sample for off-line analysis and to use chemicals. Despite the complexity associated with wastewater treatment systems, spectroscopic methods coupled with chemometric tools have been shown to be powerful tools for bioprocess monitoring and control. Once implemented and optimized, these methods are fast, nondestructive, user friendly, and most importantly, they can be implemented in situ, permitting rapid inference of the process state at any moment. In this work, UV-visible and NIR spectroscopy were used to monitor an activated sludge reactor using in situ immersion probes connected to the respective analyzers by optical fibers. During the monitoring period, disturbances to the biological system were induced to test the ability of each spectroscopic method to detect the changes in the system. Calibration models based on partial least squares (PLS) regression were developed for three key process parameters, namely chemical oxygen demand (COD), nitrate concentration (N-NO(3)(-)), and total suspended solids (TSS). For NIR, the best results were achieved for TSS, with a relative error of 14.1% and a correlation coefficient of 0.91. The UV-visible technique gave similar results for the three parameters: an error of approximately 25% and correlation coefficients of approximately 0.82 for COD and TSS and 0.87 for N-NO(3)(-) . The results obtained demonstrate that both techniques are suitable for consideration as alternative methods for monitoring and controlling wastewater treatment processes, presenting clear advantages when compared with the reference methods for wastewater treatment process qualification.
NASA Astrophysics Data System (ADS)
Volkmann, T. H. M.; Van Haren, J. L. M.; Kim, M.; Harman, C. J.; Pangle, L.; Meredith, L. K.; Troch, P. A.
2017-12-01
Stable isotope analysis is a powerful tool for tracking flow pathways, residence times, and the partitioning of water resources through catchments. However, the capacity of stable isotopes to characterize catchment hydrological dynamics has not been fully exploited as commonly used methodologies constrain the frequency and extent at which isotopic data is available across hydrologically-relevant compartments (e.g. soil, plants, atmosphere, streams). Here, building upon significant recent developments in laser spectroscopy and sampling techniques, we present a fully automated monitoring network for tracing water isotopes through the three model catchments of the Landscape Evolution Observatory (LEO) at the Biosphere 2, University of Arizona. The network implements state-of-the-art techniques for monitoring in great spatiotemporal detail the stable isotope composition of water in the subsurface soil, the discharge outflow, and the atmosphere above the bare soil surface of each of the 330-m2 catchments. The extensive valving and probing systems facilitate repeated isotope measurements from a total of more than five-hundred locations across the LEO domain, complementing an already dense array of hydrometric and other sensors installed on, within, and above each catchment. The isotope monitoring network is operational and was leveraged during several months of experimentation with deuterium-labelled rain pulse applications. Data obtained during the experiments demonstrate the capacity of the monitoring network to resolve sub-meter to whole-catchment scale flow and transport dynamics in continuous time. Over the years to come, the isotope monitoring network is expected to serve as an essential tool for collaborative interdisciplinary Earth science at LEO, allowing us to disentangle changes in hydrological behavior as the model catchments evolve in time through weathering and colonization by plant communities.
Geophysical monitoring technology for CO2 sequestration
NASA Astrophysics Data System (ADS)
Ma, Jin-Feng; Li, Lin; Wang, Hao-Fan; Tan, Ming-You; Cui, Shi-Ling; Zhang, Yun-Yin; Qu, Zhi-Peng; Jia, Ling-Yun; Zhang, Shu-Hai
2016-06-01
Geophysical techniques play key roles in the measuring, monitoring, and verifying the safety of CO2 sequestration and in identifying the efficiency of CO2-enhanced oil recovery. Although geophysical monitoring techniques for CO2 sequestration have grown out of conventional oil and gas geophysical exploration techniques, it takes a long time to conduct geophysical monitoring, and there are many barriers and challenges. In this paper, with the initial objective of performing CO2 sequestration, we studied the geophysical tasks associated with evaluating geological storage sites and monitoring CO2 sequestration. Based on our review of the scope of geophysical monitoring techniques and our experience in domestic and international carbon capture and sequestration projects, we analyzed the inherent difficulties and our experiences in geophysical monitoring techniques, especially, with respect to 4D seismic acquisition, processing, and interpretation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1280... Modification or Reconstruction is Commenced After June 6, 2001 Continuous Emission Monitoring § 60.1280 What must I do if any of my continuous emission monitoring systems are temporarily unavailable to meet the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 62.15215 Section 62.15215 Protection of Environment... required for my continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each...
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are temporarily unavailable to meet the data collection requirements? 60.1280... Modification or Reconstruction is Commenced After June 6, 2001 Continuous Emission Monitoring § 60.1280 What must I do if any of my continuous emission monitoring systems are temporarily unavailable to meet the...
Auletta, Sveva; Bonfiglio, Rita; Wunder, Andreas; Varani, Michela; Galli, Filippo; Borri, Filippo; Scimeca, Manuel; Niessen, Heiko G; Schönberger, Tanja; Bonanno, Elena
2018-03-01
Inflammatory bowel diseases are lifelong disorders affecting the gastrointestinal tract characterized by intermittent disease flares and periods of remission with a progressive and destructive nature. Unfortunately, the exact etiology is still not completely known, therefore a causal therapy to cure the disease is not yet available. Current treatment options mainly encompass the use of non-specific anti-inflammatory agents and immunosuppressive drugs that cause significant side effects that often have a negative impact on patients' quality of life. As the majority of patients need a long-term follow-up it would be ideal to rely on a non-invasive technique with good compliance. Currently, the gold standard diagnostic tools for managing IBD are represented by invasive procedures such as colonoscopy and histopathology. Nevertheless, recent advances in imaging technology continue to improve the ability of imaging techniques to non-invasively monitor disease activity and treatment response in preclinical models of IBD. Novel and emerging imaging techniques not only allow direct visualization of intestinal inflammation, but also enable molecular imaging and targeting of specific alterations of the inflamed murine mucosa. Furthermore, molecular imaging advances allow us to increase our knowledge on the critical biological pathways involved in disease progression by characterizing in vivo processes at a cellular and molecular level and enabling significant improvements in the understanding of the etiology of IBD. This review presents a critical and updated overview on the imaging advances in animal models of IBD. Our aim is to highlight the potential beneficial impact and the range of applications that imaging techniques could offer for the improvement of the clinical monitoring and management of IBD patients: diagnosis, staging, determination of therapeutic targets, monitoring therapy and evaluation of the prognosis, personalized therapeutic approaches.
Continuous monitoring of high-rise buildings using seismic interferometry
NASA Astrophysics Data System (ADS)
Mordret, A.; Sun, H.; Prieto, G. A.; Toksoz, M. N.; Buyukozturk, O.
2016-12-01
The linear seismic response of a building is commonly extracted from ambient vibration measurements. Seismic deconvolution interferometry performed on ambient vibration measurements can also be used to estimate the dynamic characteristics of a building, such as the velocity of shear-waves travelling inside the building as well as a damping parameter depending on the intrinsic attenuation of the building and the soil-structure coupling. The continuous nature of the ambient vibrations allows us to measure these parameters repeatedly and to observe their temporal variations. We used 2 weeks of ambient vibration recorded by 36 accelerometers installed in the Green Building on the Massachusetts Institute of Technology campus (Cambridge, MA) to continuously monitor the shear-wave speed and the attenuation factor of the building. Due to the low strain of the ambient vibrations, the observed changes are totally reversible. The relative velocity changes between a reference deconvolution function and the current deconvolution functions are measured with two different methods: 1) the Moving Window Cross-Spectral technique and 2) the stretching technique. Both methods show similar results. We show that measuring the stretching coefficient for the deconvolution functions filtered around the fundamental mode frequency is equivalent to measuring the wandering of the fundamental frequency in the raw ambient vibration data. By comparing these results with local weather parameters, we show that the relative air humidity is the factor dominating the relative seismic velocity variations in the Green Building, as well as the wandering of the fundamental mode. The one-day periodic variations are affected by both the temperature and the humidity. The attenuation factor, measured as the exponential decay of the fundamental mode waveforms, shows a more complex behaviour with respect to the weather measurements.
Operational monitoring of land-cover change using multitemporal remote sensing data
NASA Astrophysics Data System (ADS)
Rogan, John
2005-11-01
Land-cover change, manifested as either land-cover modification and/or conversion, can occur at all spatial scales, and changes at local scales can have profound, cumulative impacts at broader scales. The implication of operational land-cover monitoring is that researchers have access to a continuous stream of remote sensing data, with the long term goal of providing for consistent and repetitive mapping. Effective large area monitoring of land-cover (i.e., >1000 km2) can only be accomplished by using remotely sensed images as an indirect data source in land-cover change mapping and as a source for land-cover change model projections. Large area monitoring programs face several challenges: (1) choice of appropriate classification scheme/map legend over large, topographically and phenologically diverse areas; (2) issues concerning data consistency and map accuracy (i.e., calibration and validation); (3) very large data volumes; (4) time consuming data processing and interpretation. Therefore, this dissertation research broadly addresses these challenges in the context of examining state-of-the-art image pre-processing, spectral enhancement, classification, and accuracy assessment techniques to assist the California Land-cover Mapping and Monitoring Program (LCMMP). The results of this dissertation revealed that spatially varying haze can be effectively corrected from Landsat data for the purposes of change detection. The Multitemporal Spectral Mixture Analysis (MSMA) spectral enhancement technique produced more accurate land-cover maps than those derived from the Multitemporal Kauth Thomas (MKT) transformation in northern and southern California study areas. A comparison of machine learning classifiers showed that Fuzzy ARTMAP outperformed two classification tree algorithms, based on map accuracy and algorithm robustness. Variation in spatial data error (positional and thematic) was explored in relation to environmental variables using geostatistical interpolation techniques. Finally, the land-cover modification maps generated for three time intervals (1985--1990--1996--2000), with nine change-classes revealed important variations in land-cover gain and loss between northern and southern California study areas.
Improving nurses' knowledge of continuous ST-segment monitoring.
Chronister, Connie
2014-01-01
Continuous ST-segment monitoring can result in detection of myocardial ischemia, but in clinical practice, continuous ST-segment monitoring is conducted incorrectly and underused by many registered nurses (RNs). Many RNs are unable to correctly institute ST-segment monitoring guidelines because of a lack of education. To evaluate whether an educational intervention, provided to 32 RNs, increases knowledge and correct clinical decision making (CDM) for the use of continuous ST-segment monitoring. At a single institution, an ST-segment monitoring class was provided to RNs in 2 cardiovascular units. Knowledge and correct CDM instruments were used for a baseline pretest and subsequent posttest after ST-segment monitoring education. Statistical significance between pretest and posttest scores for knowledge and correct CDM practice was noted with dependent t tests (P = .0001). Many RNs responsible for electrocardiographic monitoring are not aware of evidence-based ST-segment monitoring practice guidelines and cannot properly place precordial leads needed for ST-segment monitoring. Knowledge and correct CDM with ST-segment monitoring can be improved with focused education.
Hirsch, Irl B; Verderese, Carol A
2017-11-01
Recent consensus statements strongly advocate downloading and interpreting continuous glucose data for diabetes management in patients with type 1 or 2 diabetes. Supplementing periodic glycated hemoglobin (A1C) testing with intermittent continuous glucose monitoring (CGM) using a standardized report form known as the ambulatory glucose profile (AGP) is an evolving standard of care. The rationale for this approach and its implementation with a recently approved novel monitoring technology are explored. Search of the medical literature, professional guidelines, and real-world evidence guided this introduction of an integrative practice framework that uses AGP in conjunction with intermittent flash continuous glucose monitoring (FCGM) as a supplement to A1C testing. The combination of intermittent continuous glucose pattern analysis, standardized glucose metrics, and a readily interpretable data report has the potential to practically extend the recognized benefits of CGM to more patients and clarify the relationship between A1C and average glucose levels in individual cases. Novel FCGM technologies portend greater use of continuous forms of glucose monitoring and wider adoption of AGP report analysis. Additional formal and empirical evidence is needed to more fully characterize best practice. A1C = glycated hemoglobin; AGP = ambulatory glucose profile; CGM = continuous glucose monitoring; FCGM = flash continuous glucose monitoring; IQR = interquartile range; SMBG = self-monitoring of blood glucose.
Lidar investigations of thermal regime and aerosol stratification of the stratosphere over tomsk
NASA Astrophysics Data System (ADS)
Matvienko, Gennady; Marichev, Valeriy; Bochkovsky, Dmitry
2018-04-01
One of the important applications of lidar techniques is the study of thermal regime and aerosol content of the stratosphere. Such investigations in monitoring mode were started at the Institute of atmospheric optics since 1994 and are continued to date. The main attention is paid for the study of the unexpected disturbances caused by winter stratospheric warming. In this paper we present the results of the study of the vertical distribution of temperature and aerosol over Tomsk of last years.
NASA Astrophysics Data System (ADS)
Fiorini, A. R.; Fumero, R.; Marchesi, R.
1983-03-01
Extracorporeal circulation allows direct access inside the chest: it may be used to carry out physiological research. The thermo-chemical protection of myocardium during heart surgery, called cardioplegy, is one of the latest outstanding techniques in patient safety. Thermocardiography monitoring during the infusion of the cardioplegic solution allows continuous assessment of rapid temperature distribution changes and shows exactly the extent of myocardium involved. Using a peculiar pseudocolor digital image enhancement, it is possible to emphasize involved areas coronary flow and to model the thermo-fluid-dynamical actions of inspected heart.
InSAR Monitoring of Landslides using RADARSAT and Alos
NASA Astrophysics Data System (ADS)
Singhroy, V.; Pierre-Jean, A.; Pavlic, G.
2009-05-01
We present the results of InSAR monitoring of several landslides using RADARDAT, and ALOS satellites. InSAR techniques are increasingly being used in slope stability assessment. Our research has shown that differential InSAR and coherent target monitoring techniques using field corner reflectors are useful to monitor landslide activity along strategic transportation and energy corridors. The Mackenzie Valley in northern Canada is experiencing one of the highest rates on mean annual air temperature for any region in Canada, thereby triggering melting in the permafrost, which results in active layer detachment slides. There are approximately 2000 landslides along the proposed Mackenzie Valley pipeline route. In addition, the Trans Canada Highway in the Canadian Rockies are affected by several rock avalanches and slow retrogressive slides. The ALOS PALSAR InSAR results show that we can observe deformation on both vegetated and exposed rock areas on the Little Smokey slide and the Frank Slide. RADARSAT-1 InSAR images indicate the different level of activity of the slopes (large and small) during different periods of the year. RADARSAT-2 is providing the high resolution rapid revisit capabilities needed to continuously monitor these active slopes along Canadian strategic energy and transportation corridors. The information produced by our InSAR activity maps on various landslides are used to realign the pipeline route in sensitive permafrost areas, and to install slope stability measures along the Trans-Canada and Provincial Highways. Using these different satellites we are able to develop guidelines for more reliable uses of these SAR missions Keywords: InSAR, landslides, RADARSAT, ALOS .
Monitoring fossil fuel sources of methane in Australia
NASA Astrophysics Data System (ADS)
Loh, Zoe; Etheridge, David; Luhar, Ashok; Hibberd, Mark; Thatcher, Marcus; Noonan, Julie; Thornton, David; Spencer, Darren; Gregory, Rebecca; Jenkins, Charles; Zegelin, Steve; Leuning, Ray; Day, Stuart; Barrett, Damian
2017-04-01
CSIRO has been active in identifying and quantifying methane emissions from a range of fossil fuel sources in Australia over the past decade. We present here a history of the development of our work in this domain. While we have principally focused on optimising the use of long term, fixed location, high precision monitoring, paired with both forward and inverse modelling techniques suitable either local or regional scales, we have also incorporated mobile ground surveys and flux calculations from plumes in some contexts. We initially developed leak detection methodologies for geological carbon storage at a local scale using a Bayesian probabilistic approach coupled to a backward Lagrangian particle dispersion model (Luhar et al. JGR, 2014), and single point monitoring with sector analysis (Etheridge et al. In prep.) We have since expanded our modelling techniques to regional scales using both forward and inverse approaches to constrain methane emissions from coal mining and coal seam gas (CSG) production. The Surat Basin (Queensland, Australia) is a region of rapidly expanding CSG production, in which we have established a pair of carefully located, well-intercalibrated monitoring stations. These data sets provide an almost continuous record of (i) background air arriving at the Surat Basin, and (ii) the signal resulting from methane emissions within the Basin, i.e. total downwind methane concentration (comprising emissions including natural geological seeps, agricultural and biogenic sources and fugitive emissions from CSG production) minus background or upwind concentration. We will present our latest results on monitoring from the Surat Basin and their application to estimating methane emissions.
Toward minimally invasive, continuous glucose monitoring in vivo
NASA Astrophysics Data System (ADS)
Vrancic, Christian; Gretz, Norbert; Kröger, Niels; Neudecker, Sabine; Pucci, Annemarie; Petrich, Wolfgang
2012-01-01
Diabetes mellitus is a disorder of glucose metabolism and it is one of the most challenging diseases, both from a medical and economic perspective. People with diabetes can benefit from a frequent or even continuous monitoring of their blood glucose concentrations. The approach presented here takes advantage of the observational nature of biomedical vibrational spectroscopy in contrast to chemical reactions which consume glucose. The particular technique employed here is based on the high sensitivity of mid-infrared transmission spectroscopy where strong vibrational bands of glucose can be monitored at wavelengths around 10 μm. The strong absorption of water in this spectral region was mitigated by the use of quantum cascade lasers and very short interaction path lengths below 50 μm. Various sensor concepts have been explored. In one of the concepts, the interaction of mid-infrared radiation with glucose is established within a miniature measurement cavity, formed by a gap between two silver halide fibers. In recent experiments, an additional quantum cascade laser was used for reference purposes. The long-term drift could significantly be reduced for time intervals > 1000 s, e. g., by more than 60% for a 3 hour interval. This extension for the compensation of long-term drifts of the measurement system in vitro is an important contribution towards the applicability in vivo.
Kögler, Martin; Paul, Andrea; Anane, Emmanuel; Birkholz, Mario; Bunker, Alex; Viitala, Tapani; Maiwald, Michael; Junne, Stefan; Neubauer, Peter
2018-06-08
The application of Raman spectroscopy as a monitoring technique for bioprocesses is severely limited by a large background signal originating from fluorescing compounds in the culture media. Here we compare time-gated Raman (TG-Raman)-, continuous wave NIR-process Raman (NIR-Raman) and continuous wave micro-Raman (micro-Raman) approaches in combination with surface enhanced Raman spectroscopy (SERS) for their potential to overcome this limit. For that purpose, we monitored metabolite concentrations of Escherichia coli bioreactor cultivations in cell-free supernatant samples. We investigated concentration transients of glucose, acetate, AMP and cAMP at alternating substrate availability, from deficiency to excess. Raman and SERS signals were compared to off-line metabolite analysis of carbohydrates, carboxylic acids and nucleotides. Results demonstrate that SERS, in almost all cases, led to a higher number of identifiable signals and better resolved spectra. Spectra derived from the TG-Raman were comparable to those of micro-Raman resulting in well-discernable Raman peaks, which allowed for the identification of a higher number of compounds. In contrast, NIR-Raman provided a superior performance for the quantitative evaluation of analytes, both with and without SERS nanoparticles when using multivariate data analysis. This article is protected by copyright. All rights reserved. © 2018 American Institute of Chemical Engineers.
Thermal photogrammetric imaging: A new technique for monitoring dome eruptions
NASA Astrophysics Data System (ADS)
Thiele, Samuel T.; Varley, Nick; James, Mike R.
2017-05-01
Structure-from-motion (SfM) algorithms greatly facilitate the generation of 3-D topographic models from photographs and can form a valuable component of hazard monitoring at active volcanic domes. However, model generation from visible imagery can be prevented due to poor lighting conditions or surface obscuration by degassing. Here, we show that thermal images can be used in a SfM workflow to mitigate these issues and provide more continuous time-series data than visible-light equivalents. We demonstrate our methodology by producing georeferenced photogrammetric models from 30 near-monthly overflights of the lava dome that formed at Volcán de Colima (Mexico) between 2013 and 2015. Comparison of thermal models with equivalents generated from visible-light photographs from a consumer digital single lens reflex (DSLR) camera suggests that, despite being less detailed than their DSLR counterparts, the thermal models are more than adequate reconstructions of dome geometry, giving volume estimates within 10% of those derived using the DSLR. Significantly, we were able to construct thermal models in situations where degassing and poor lighting prevented the construction of models from DSLR imagery, providing substantially better data continuity than would have otherwise been possible. We conclude that thermal photogrammetry provides a useful new tool for monitoring effusive volcanic activity and assessing associated volcanic risks.
Update to Permeable Pavement Research at the Edison ...
The EPA’s Urban Watershed Management Branch (UWMB) has been monitoring the permeable pavement demonstration site at the Edison Environmental Center, NJ since 2010. This site has three different types of permeable pavements including interlocking concrete permeable pavers, pervious concrete, and porous asphalt. The permeable pavements are limited to parking spaces while adjacent driving lanes are impermeable and drain to the permeable surfaces. The parking lot is instrumented for continuous monitoring with thermistors and water content reflectometers that measure moisture as infiltrate passes through the storage gallery beneath the permeable pavements into the underlying native soil. Each permeable surface of the parking lot has four lined sections that capture infiltrate in tanks for water quality analyses; these tanks are capable of holding volumes up to 4.1 m3, which represents up to 38 mm (1.5 in.) for direct rainfall on the porous pavement and runoff from adjacent driving lanes that drain into the permeable surface.Previous technical releases concerning the demonstration site focused on monitoring techniques, observed chloride and nutrient concentrations, surface hydrology, and infiltration and evaporation rates. This presentation summarizes these past findings and addresses current water quality efforts including pH, solids analysis, total organic carbon, and chemical oxygen demand. Stormwater runoff continues to be a major cause of water pollution in
National survey of cardiologists' standard of practice for continuous ST-segment monitoring.
Sandau, Kristin E; Sendelbach, Sue; Frederickson, Joel; Doran, Karen
2010-03-01
Continuous ST-segment monitoring can be used to detect early and transient cardiac ischemia. The American Heart Association and American Association of Critical-Care Nurses recommend its use among specific patients, but such monitoring is routine practice in only about half of US hospitals. To determine cardiologists' awareness and practice standards regarding continuous ST-segment monitoring and the physicians' perceptions of appropriate patient selection, benefits and barriers, and usefulness of this technology. An electronic survey was sent to a random sample of 915 US cardiologists from a pool of 4985 certified cardiologists. Of 200 responding cardiologists, 55% were unaware of the consensus guidelines. Of hospitals where respondents admitted patients, 49% had a standard of practice for using continuous ST-segment monitoring for cardiac patients. Most cardiologists agreed or strongly agreed that patients in the cardiovascular laboratory (87.5%) and intensive care unit (80.5%) should have such monitoring. Cardiologists routinely ordered ST monitoring for patients with acute coronary syndrome (67%) and after percutaneous coronary intervention (60%). The primary factor associated with higher perceptions for benefits, clinical usefulness, and past use of continuous ST-segment monitoring was whether or not hospitals in which cardiologists practiced had a standard of practice for using this monitoring. A secondary factor was awareness of published consensus guidelines for such monitoring. Respondents (55%) were unaware of published monitoring guidelines. Hospital leaders could raise awareness by multidisciplinary review of evidence and possibly incorporating continuous ST-segment monitoring into hospitals' standards of practice.
Code of Federal Regulations, 2012 CFR
2012-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... Commenced After June 6, 2001 Continuous Emission Monitoring § 60.1245 Am I exempt from any appendix B or... carbon dioxide) continuous emission monitoring system. Therefore, your oxygen (or carbon dioxide...
Evaluation method of leachate leaking from carcass burial site
NASA Astrophysics Data System (ADS)
Park, S.; Kim, H.; Lee, M.; Lee, K.; Kim, S.; Kim, M.; Kim, H.; Kim, T.; Han, J.
2012-12-01
More than 150,000 cattle carcasses and 3,140,000 pig carcasses were buried all over the nation in Korea because of 2010 outbreak of foot and mouth disease (FMD). Various disposal Techniques such as incineration, composting, rendering, and burial have been developed and applied to effectively dispose an animal carcass. Since a large number of carcasses should be disposed for a short-term period to prevent the spread of FMD virus, most of the carcasses were disposed by mass burial technique. However, a long-term management and monitoring of leachate discharges are required because mass burial can cause soil and groundwater contamination. In this study, we used key parameters related to major components of leachate such as NH4-N, NO3-N, Cl-, E.coli and electrical conductivity as potential leachate contamination indicator to determine leachate leakage from the site. We monitored 300 monitoring wells in both burial site and the monitoring well 5m away from burial sites to identify leachate leaking from burial site. Average concentration of NH3-N in 300 monitoring wells, both burial site and the well 5m away from burial sites, were 2,593 mg/L and 733 mg/L, respectively. 24% out of 300 monitoring wells showed higher than 10 mg/L NH4-N, 100 mg/L Cl- and than 800 μS/cm electrical conductivity. From this study, we set up 4 steps guidelines to evaluate leachate leakage like; step 1 : High potential step of leachate leakage, step 2 : Middle potential step of leachate leakage, step 3 : Low potential step of leachate leakage, step 4 : No leachate leakage. On the basis of this result, we moved 34 leachate leaking burial sites to other places safely and it is necessary to monitor continuously the monitoring wells for environmental protection and human health.
Visual Sensing for Urban Flood Monitoring
Lo, Shi-Wei; Wu, Jyh-Horng; Lin, Fang-Pang; Hsu, Ching-Han
2015-01-01
With the increasing climatic extremes, the frequency and severity of urban flood events have intensified worldwide. In this study, image-based automated monitoring of flood formation and analyses of water level fluctuation were proposed as value-added intelligent sensing applications to turn a passive monitoring camera into a visual sensor. Combined with the proposed visual sensing method, traditional hydrological monitoring cameras have the ability to sense and analyze the local situation of flood events. This can solve the current problem that image-based flood monitoring heavily relies on continuous manned monitoring. Conventional sensing networks can only offer one-dimensional physical parameters measured by gauge sensors, whereas visual sensors can acquire dynamic image information of monitored sites and provide disaster prevention agencies with actual field information for decision-making to relieve flood hazards. The visual sensing method established in this study provides spatiotemporal information that can be used for automated remote analysis for monitoring urban floods. This paper focuses on the determination of flood formation based on image-processing techniques. The experimental results suggest that the visual sensing approach may be a reliable way for determining the water fluctuation and measuring its elevation and flood intrusion with respect to real-world coordinates. The performance of the proposed method has been confirmed; it has the capability to monitor and analyze the flood status, and therefore, it can serve as an active flood warning system. PMID:26287201
Denaï, Mouloud A; Mahfouf, Mahdi; Mohamad-Samuri, Suzani; Panoutsos, George; Brown, Brian H; Mills, Gary H
2010-05-01
Thoracic electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring technique whose aim is to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. The purpose of this paper is to discuss the fundamentals of EIT and demonstrate the principles of mechanical ventilation, lung recruitment, and EIT imaging on a comprehensive physiological model, which combines a model of respiratory mechanics, a model of the human lung absolute resistivity as a function of air content, and a 2-D finite-element mesh of the thorax to simulate EIT image reconstruction during mechanical ventilation. The overall model gives a good understanding of respiratory physiology and EIT monitoring techniques in mechanically ventilated patients. The model proposed here was able to reproduce consistent images of ventilation distribution in simulated acutely injured and collapsed lung conditions. A new advisory system architecture integrating a previously developed data-driven physiological model for continuous and noninvasive predictions of blood gas parameters with the regional lung function data/information generated from absolute EIT (aEIT) is proposed for monitoring and ventilator therapy management of critical care patients.
NASA Technical Reports Server (NTRS)
Abdul-Aziz, Ali; Baaklini, George Y.; Roth, Don J.
2004-01-01
Engine makers and aviation safety government institutions continue to have a strong interest in monitoring the health of rotating components in aircraft engines to improve safety and to lower maintenance costs. To prevent catastrophic failure (burst) of the engine, they use nondestructive evaluation (NDE) and major overhauls for periodic inspections to discover any cracks that might have formed. The lowest cost fluorescent penetrant inspection NDE technique can fail to disclose cracks that are tightly closed during rest or that are below the surface. The NDE eddy current system is more effective at detecting both crack types, but it requires careful setup and operation and only a small portion of the disk can be practically inspected. So that sensor systems can sustain normal function in a severe environment, health-monitoring systems require the sensor system to transmit a signal if a crack detected in the component is above a predetermined length (but below the length that would lead to failure) and lastly to act neutrally upon the overall performance of the engine system and not interfere with engine maintenance operations. Therefore, more reliable diagnostic tools and high-level techniques for detecting damage and monitoring the health of rotating components are very essential in maintaining engine safety and reliability and in assessing life.
Markides, Andreas; Skillman, Severin; Acton, Sahr Thomas; Elsaleh, Tarek; Hassanpour, Masoud; Ahrabian, Alireza; Kenny, Mark; Klein, Stuart; Rostill, Helen; Nilforooshan, Ramin; Barnaghi, Payam
2018-01-01
The number of people diagnosed with dementia is expected to rise in the coming years. Given that there is currently no definite cure for dementia and the cost of care for this condition soars dramatically, slowing the decline and maintaining independent living are important goals for supporting people with dementia. This paper discusses a study that is called Technology Integrated Health Management (TIHM). TIHM is a technology assisted monitoring system that uses Internet of Things (IoT) enabled solutions for continuous monitoring of people with dementia in their own homes. We have developed machine learning algorithms to analyse the correlation between environmental data collected by IoT technologies in TIHM in order to monitor and facilitate the physical well-being of people with dementia. The algorithms are developed with different temporal granularity to process the data for long-term and short-term analysis. We extract higher-level activity patterns which are then used to detect any change in patients’ routines. We have also developed a hierarchical information fusion approach for detecting agitation, irritability and aggression. We have conducted evaluations using sensory data collected from homes of people with dementia. The proposed techniques are able to recognise agitation and unusual patterns with an accuracy of up to 80%. PMID:29723236
[Analysis of the current status of neuroanesthesia in Spain using a national survey].
Fábregas, N; Salvador, L; Valero, R; Carrero, E; Gomar, C; Nalda, M A
1998-05-01
Advances in complementary diagnostic explorations, surgical support technology and the complexity of neurophysiological monitoring require anesthesiologists to acquire specific knowledge for dealing with neurosurgery. We aimed to study the implantation of new anesthetic-surgical techniques in the field of neurosurgery, and the state of neuroanesthesia as a subspecialty in Spain. A 20-item postal questionnaire sent to anesthesiology department heads of Spanish hospitals with neurosurgery teams. We received responses from 62% of the hospitals surveyed. Of these, 69% performed stereotaxic surgery, 30% functional cerebral surgery (for Parkinson's disease and epilepsy) and 21% offered neuroendoscopy. In 38% of the hospitals cerebral metabolism was monitored (hemoglobin oxygen saturation in the jugular or regional cerebral oxygen saturation) and/or cerebral electrophysiology (electroencephalogram, evoked potentials) and in 23.8% flows and pressures were measured (transcranial precordial and/or tracheoesophageal Doppler). Anesthesiologists specializing in neurosurgery are present in 62% of the hospitals. Interventionist neuroradiology is performed in 57%. It was noteworthy that 14.3% do not regularly have an anesthesiologist present during such high risk procedures. Although most centers continue performing "classical" neurosurgery with standard monitoring, a substantial proportion of hospitals (38%) show evidence of advancing in anesthetic techniques for neurosurgery in Spain. Anesthesia for neurosurgery as a subspecialty is available in 62% of the responding hospitals.
NASA Astrophysics Data System (ADS)
Meng, Xiaobo; Chen, Haichao; Niu, Fenglin; Tang, Youcai; Yin, Chen; Wu, Furong
2018-02-01
We introduce an improved matching and locating technique to detect and locate microseismic events (-4 < ML < 0) associated with hydraulic fracturing treatment. We employ a set of representative master events to act as template waveforms and detect slave events that strongly resemble master events through stacking cross correlograms of both P and S waves between the template waveforms and the continuous records of the monitoring array. Moreover, the residual moveout in the cross correlograms across the array is used to locate slave events relative to the corresponding master event. In addition, P wave polarization constraint is applied to resolve the lateral extent of slave events in the case of unfavorable array configuration. We first demonstrate the detectability and location accuracy of the proposed approach with a pseudo-synthetic data set. Compared to the matched filter analysis, the proposed approach can significantly enhance detectability at low false alarm rate and yield robust location estimates of very low SNR events, particularly along the vertical direction. Then, we apply the method to a real microseismic data set acquired in the Weiyuan shale reservoir of China in November of 2014. The expanded microseismic catalog provides more easily interpretable spatiotemporal evolution of microseismicity, which is investigated in detail in a companion paper.
Toward a comprehensive landscape vegetation monitoring framework
NASA Astrophysics Data System (ADS)
Kennedy, Robert; Hughes, Joseph; Neeti, Neeti; Larrue, Tara; Gregory, Matthew; Roberts, Heather; Ohmann, Janet; Kane, Van; Kane, Jonathan; Hooper, Sam; Nelson, Peder; Cohen, Warren; Yang, Zhiqiang
2016-04-01
Blossoming Earth observation resources provide great opportunity to better understand land vegetation dynamics, but also require new techniques and frameworks to exploit their potential. Here, I describe several parallel projects that leverage time-series Landsat imagery to describe vegetation dynamics at regional and continental scales. At the core of these projects are the LandTrendr algorithms, which distill time-series earth observation data into periods of consistent long or short-duration dynamics. In one approach, we built an integrated, empirical framework to blend these algorithmically-processed time-series data with field data and lidar data to ascribe yearly change in forest biomass across the US states of Washington, Oregon, and California. In a separate project, we expanded from forest-only monitoring to full landscape land cover monitoring over the same regional scale, including both categorical class labels and continuous-field estimates. In these and other projects, we apply machine-learning approaches to ascribe all changes in vegetation to driving processes such as harvest, fire, urbanization, etc., allowing full description of both disturbance and recovery processes and drivers. Finally, we are moving toward extension of these same techniques to continental and eventually global scales using Google Earth Engine. Taken together, these approaches provide one framework for describing and understanding processes of change in vegetation communities at broad scales.
Enshaeifar, Shirin; Zoha, Ahmed; Markides, Andreas; Skillman, Severin; Acton, Sahr Thomas; Elsaleh, Tarek; Hassanpour, Masoud; Ahrabian, Alireza; Kenny, Mark; Klein, Stuart; Rostill, Helen; Nilforooshan, Ramin; Barnaghi, Payam
2018-01-01
The number of people diagnosed with dementia is expected to rise in the coming years. Given that there is currently no definite cure for dementia and the cost of care for this condition soars dramatically, slowing the decline and maintaining independent living are important goals for supporting people with dementia. This paper discusses a study that is called Technology Integrated Health Management (TIHM). TIHM is a technology assisted monitoring system that uses Internet of Things (IoT) enabled solutions for continuous monitoring of people with dementia in their own homes. We have developed machine learning algorithms to analyse the correlation between environmental data collected by IoT technologies in TIHM in order to monitor and facilitate the physical well-being of people with dementia. The algorithms are developed with different temporal granularity to process the data for long-term and short-term analysis. We extract higher-level activity patterns which are then used to detect any change in patients' routines. We have also developed a hierarchical information fusion approach for detecting agitation, irritability and aggression. We have conducted evaluations using sensory data collected from homes of people with dementia. The proposed techniques are able to recognise agitation and unusual patterns with an accuracy of up to 80%.