40 CFR 60.1715 - What types of continuous emission monitoring must I perform?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines... must I perform? To continuously monitor emissions, you must perform four tasks: (a) Install continuous...
40 CFR 60.1225 - What types of continuous emission monitoring must I perform?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30... emissions, you must perform four tasks: (a) Install continuous emission monitoring systems for certain...
40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring...
Code of Federal Regulations, 2010 CFR
2010-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... monitoring system according to § 60.13. (c) Complete an initial evaluation of your continuous opacity monitoring system according to Performance Specification 1 in appendix B of this part. Complete the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring system equipment, if I choose to use this option? 60.4345 Section 60.4345... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4345 What are the requirements for the continuous emission monitoring system equipment, if I...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring... additional requirements must I meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values and applicable performance specifications...
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems...
40 CFR 60.175 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc... monitor and record the opacity of gases discharged into the atmosphere from any sintering machine. The... volume. (i) The continuous monitoring system performance evaluation required under § 60.13(c) shall be...
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission...
40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced...
40 CFR Table 4 to Subpart Hhhhhhh... - Applicability of the General Provisions to Part 63
Code of Federal Regulations, 2014 CFR
2014-07-01
... SSM plan for continuous monitoring systems No. § 63.8(c)(5) Continuous opacity monitoring system...) Written procedures for continuous monitoring systems Yes, except for last sentence, which refers to an SSM plan. SSM plans are not required § 63.8(e) Continuous monitoring systems performance evaluation Yes...
40 CFR Table 7 to Subpart Vvvv of... - Applicability and Timing of Notifications
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.9(e). b. A notification of the date for the continuous monitoring system performance evaluation as... control device performance test and continuous monitoring system performance evaluation. ... Notifications 7 Table 7 to Subpart VVVV of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
Continued Monitoring of Indiana's SPS9-A Site
DOT National Transportation Integrated Search
2012-07-01
This study was initiated to continue monitoring the performance of five test sections placed in 1997 to compare the performance of : Superpave asphalt mixtures with different binder grades and one test section designed using the Marshall mix design m...
Use of Continuous Integration Tools for Application Performance Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vergara Larrea, Veronica G; Joubert, Wayne; Fuson, Christopher B
High performance computing systems are becom- ing increasingly complex, both in node architecture and in the multiple layers of software stack required to compile and run applications. As a consequence, the likelihood is increasing for application performance regressions to occur as a result of routine upgrades of system software components which interact in complex ways. The purpose of this study is to evaluate the effectiveness of continuous integration tools for application performance monitoring on HPC systems. In addition, this paper also describes a prototype system for application perfor- mance monitoring based on Jenkins, a Java-based continuous integration tool. The monitoringmore » system described leverages several features in Jenkins to track application performance results over time. Preliminary results and lessons learned from monitoring applications on Cray systems at the Oak Ridge Leadership Computing Facility are presented.« less
CONTINUOUS PERFORMANCE MONITORING TECHNIQUES FOR HAZARDOUS WASTE INCINERATORS
The report describes a study to determine the feasibility of utilizing realtime continuous exhaust measurements of combustion intermediates as a way to monitor incinerator performance. The key issue was to determine if a direct correlation exists between destruction efficiency (D...
40 CFR 63.567 - Recordkeeping and reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... emissions and monitoring system performance reports—(1) Schedule for summary report and excess emissions and monitoring system performance reports. Excess emissions and parameter monitoring exceedances are defined in... install a CMS shall submit an excess emissions and continuous monitoring system performance report and/or...
Rinzler, Charles C.; Gray, William C.; Faircloth, Brian O.; Zediker, Mark S.
2016-02-23
A monitoring and detection system for use on high power laser systems, long distance high power laser systems and tools for performing high power laser operations. In particular, the monitoring and detection systems provide break detection and continuity protection for performing high power laser operations on, and in, remote and difficult to access locations.
40 CFR 63.2994 - How do I verify the performance of monitoring equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring equipment. (2) Conduct a performance evaluation of the continuous monitoring system (CMS...-specific performance evaluation plan, conduct of the performance evaluation, and reporting of performance... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I verify the performance of...
Measuring, managing and maximizing refinery performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bascur, O.A.; Kennedy, J.P.
1996-01-01
Implementing continuous quality improvement is a confluence of total quality management, people empowerment, performance indicators and information engineering. Supporting information technologies allow a refiner to narrow the gap between management objectives and the process control level. Dynamic performance monitoring benefits come from production cost savings, improved communications and enhanced decision making. A refinery workgroup information flow model helps automate continuous improvement of processes, performance and the organization. The paper discusses the rethinking of refinery operations, dynamic performance monitoring, continuous process improvement, the knowledge coordinator and repository manager, an integrated plant operations workflow, and successful implementation.
ERIC Educational Resources Information Center
Wells, Deborah L.; Moorman, Robert H.; Werner, Jon M.
2007-01-01
As a form of performance monitoring, electronic performance monitoring (EPM) offers the opportunity for unobtrusive and continuous performance data gathering. These strengths can also make EPM stressful and threatening. Many features of performance evaluation systems, including the organizational purposes for which they are used, can affect…
40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2014 CFR
2014-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... Units Model Rule-Monitoring § 60.2730 What monitoring equipment must I install and what parameters must...) of this section must be expressed in milligrams per dry standard cubic meter corrected to 7 percent...
40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2013 CFR
2013-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... Units Model Rule-Monitoring § 60.2730 What monitoring equipment must I install and what parameters must...) of this section must be expressed in milligrams per dry standard cubic meter corrected to 7 percent...
40 CFR Table 4 to Subpart Hhhhhhh... - Applicability of the General Provisions to Part 63
Code of Federal Regulations, 2013 CFR
2013-07-01
... to develop SSM plan for continuous monitoring systems No. § 63.8(c)(5) Continuous opacity monitoring... to an SSM plan. SSM plans are not required § 63.8(e) Continuous monitoring systems performance...)(iv), (b)(2)(v) Actions taken to minimize emissions during SSM No. § 63.10(b)(2)(vi) Recordkeeping for...
40 CFR 60.185 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) The continuous monitoring system performance evaluation required under § 60.13(c) shall be completed... monitoring system performance evaluation required under § 60.13(c), the reference method referred to under... be Method 6. For the performance evaluation, each concentration measurement shall be of one hour...
Continuation of superpave projects monitoring.
DOT National Transportation Integrated Search
2011-07-01
This study involved the continuous monitoring of material properties and field performance of : twelve Superpave project sections in Florida for the establishment of reasonable and effective mixture : design guidelines and criteria, the identificatio...
Code of Federal Regulations, 2010 CFR
2010-07-01
... initial evaluation of your continuous opacity monitoring system according to Performance Specification 1 in appendix B of 40 CFR part 60. Complete this evaluation by 180 days after your final compliance... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF STATE PLANS...
32 CFR 767.10 - Monitoring of performance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 5 2013-07-01 2013-07-01 false Monitoring of performance. 767.10 Section 767.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES APPLICATION... DEPARTMENT OF THE NAVY Permit Guidelines § 767.10 Monitoring of performance. Permitted activities will be...
32 CFR 767.10 - Monitoring of performance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 5 2012-07-01 2012-07-01 false Monitoring of performance. 767.10 Section 767.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES APPLICATION... DEPARTMENT OF THE NAVY Permit Guidelines § 767.10 Monitoring of performance. Permitted activities will be...
32 CFR 767.10 - Monitoring of performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 5 2010-07-01 2010-07-01 false Monitoring of performance. 767.10 Section 767.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES APPLICATION... DEPARTMENT OF THE NAVY Permit Guidelines § 767.10 Monitoring of performance. Permitted activities will be...
32 CFR 767.10 - Monitoring of performance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 5 2014-07-01 2014-07-01 false Monitoring of performance. 767.10 Section 767.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES APPLICATION... DEPARTMENT OF THE NAVY Permit Guidelines § 767.10 Monitoring of performance. Permitted activities will be...
32 CFR 767.10 - Monitoring of performance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 5 2011-07-01 2011-07-01 false Monitoring of performance. 767.10 Section 767.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES APPLICATION... DEPARTMENT OF THE NAVY Permit Guidelines § 767.10 Monitoring of performance. Permitted activities will be...
Continuation of superpave projects monitoring.
DOT National Transportation Integrated Search
2011-07-01
This study involved the continuous monitoring of material properties and field performance of twelve Superpave project sections in Florida for the establishment of reasonable and effective mixture design guidelines and criteria, the identification an...
Department of Defense Chemical and Biological Defense Program. FY2004-2006 Performance Plan
2005-03-01
Agents (NTAs) Compare the direct effects of PAF on smooth muscle, hematic constituents, and lung to determine role in toxicity. Continue to identify...Range Biometric Target ID System Explore technologies for a long range biometric target identification system. Air Containment Monitoring System...Continue development of systems for contained air monitoring for chemical agents.Long Range Biometric Air Containment Monitoring System Continued
10 CFR 600.341 - Monitoring and reporting program and financial performance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Monitoring and reporting program and financial performance. 600.341 Section 600.341 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL... Organizations Post-Award Requirements § 600.341 Monitoring and reporting program and financial performance. (a...
40 CFR 60.1330 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false How do I monitor the injection rate of activated carbon? 60.1330 Section 60.1330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustio...
40 CFR 60.1330 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false How do I monitor the injection rate of activated carbon? 60.1330 Section 60.1330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustio...
40 CFR 60.1330 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false How do I monitor the injection rate of activated carbon? 60.1330 Section 60.1330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustio...
40 CFR 60.2255 - How must I monitor opacity for air curtain incinerators?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false How must I monitor opacity for air curtain incinerators? 60.2255 Section 60.2255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Commercial and Industrial Solid...
40 CFR 60.2255 - How must I monitor opacity for air curtain incinerators?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false How must I monitor opacity for air curtain incinerators? 60.2255 Section 60.2255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Commercial and Industrial Solid...
40 CFR 60.1330 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false How do I monitor the injection rate of activated carbon? 60.1330 Section 60.1330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustio...
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, Eun-Hyung; Lee, Soo-Youn
2010-01-01
Blood glucose monitoring has been established as a valuable tool in the management of diabetes. Since maintaining normal blood glucose levels is recommended, a series of suitable glucose biosensors have been developed. During the last 50 years, glucose biosensor technology including point-of-care devices, continuous glucose monitoring systems and noninvasive glucose monitoring systems has been significantly improved. However, there continues to be several challenges related to the achievement of accurate and reliable glucose monitoring. Further technical improvements in glucose biosensors, standardization of the analytical goals for their performance, and continuously assessing and training lay users are required. This article reviews the brief history, basic principles, analytical performance, and the present status of glucose biosensors in the clinical practice. PMID:22399892
An evaluation of continuous emissions monitoring systems for improving industrial boiler efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerlin, H.M.; Hall, R.C.
1996-12-31
An experimental evaluation of currently available continuous emissions monitoring systems has been conducted at an industrial boiler facility. The analyzers used in the study represented a range of sensors and sampling systems. The performance of three systems was monitored and compared over a six-month period. Careful records were also kept on installation, calibration and maintenance requirements. Research results suggest that (at present) the close-coupled extractive systems using a zirconium oxide sensor (for O{sub 2}) and a catalytic combustibles sensor (for CO/combustibles) offer the most reliable, trouble-free performance. The project also provided valuable insights on a variety of issues relating tomore » the continuous monitoring of emissions from industrial boilers.« less
An evaluation of continuous emissions monitoring systems for improving industrial boiler efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerlin, H.M.; Hall, R.C.
1996-05-01
An experimental evaluation of currently available continuous emissions monitoring systems has been conducted at an industrial boiler facility. The analyzers used in the study represented a range of sensors and sampling systems. The performance of three systems was monitored and compared over a six-month period. Careful records were also kept on installation, calibration and maintenance requirements. Research results suggest that (at present) the close-coupled extractive systems using a zirconium oxide sensor (for O{sub 2}) and a catalytic combustibles sensor (for CO/combustibles) offer the most reliable, trouble-free performance. The project also provided valuable insights on a variety of issues relating tomore » the continuous monitoring of emissions from industrial boilers.« less
Evaluation of the Eberline AMS-3A and AMS-4 Beta continuous air monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, M.L.; Sisk, D.R.
1996-03-01
Eberline AMS-3A-1 and AMS-4 beta continuous air monitors were tested against the criteria set forth in the ANSI Standards N42.18, Specification and Performance of On-site Instrumentation for Continuously Monitoring Radioactivity in Effluents, and ANSI N42.17B, Performance Specification for Health Physics Instrumentation - Occupational Airborne Radioactivity Monitoring Instrumentation. ANSI N42.18 does not, in general, specify testing procedures for demonstrating compliance with the criteria set forth in the standard; therefore, wherever possible, the testing procedures given in ANSI N42.17B were adopted. In all cases, the more restrictive acceptance criteria and/or the more demanding test conditions of the two standards were used.
28 CFR 66.40 - Monitoring and reporting program performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... performance. 66.40 Section 66.40 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) UNIFORM... Requirements Reports, Records, Retention, and Enforcement § 66.40 Monitoring and reporting program performance... assure compliance with applicable Federal requirements and that performance goals are being achieved...
40 CFR 60.473 - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...
40 CFR 60.473 - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...
40 CFR 60.473 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt Processing and Asphalt Roofing Manufacture § 60.473 Monitoring of operations. (a) The owner or operator...
40 CFR 63.2161 - What performance tests and other procedures must I use if I monitor brew ethanol?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true What performance tests and other procedures must I use if I monitor brew ethanol? 63.2161 Section 63.2161 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National...
Code of Federal Regulations, 2014 CFR
2014-07-01
... limited to the following: (i) Inspecting the fabric filter for air leaks, torn or broken bags or filter... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... maintain your bag leak detection system in continuous operation according to your monitoring plan required...
Code of Federal Regulations, 2013 CFR
2013-07-01
... limited to the following: (i) Inspecting the fabric filter for air leaks, torn or broken bags or filter... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... maintain your bag leak detection system in continuous operation according to your monitoring plan required...
Continued monitoring of instrumented pavement in Ohio
DOT National Transportation Integrated Search
2003-12-01
Performance and environmental data continued to be monitored throughout this study on the Ohio SHRP Test Road. : Response testing included three new series of controlled vehicle tests and two sets of nondestructive tests. Cracking in two : SPS-2 sect...
Continued monitoring of instrumented pavement in Ohio.
DOT National Transportation Integrated Search
2002-12-01
Performance and environmental data continued to be monitored throughout this study on the Ohio SHRP Test Road. Response testing included three new series of controlled vehicle tests and two sets of nondestructive tests. Cracking in two SPS-2 sections...
Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.
2018-01-01
Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0-11.2) to 10.0% (95% confidence interval 6.75-13.25) and decreased the number of severe hypoglycemic events.Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring interventions to usual care. However, the uncertainty around the ICERs was large. The net budget impact of publicly funding continuous glucose monitoring assuming a 20% annual increase in adoption of continuous glucose monitoring would range from $8.5 million in year 1 to $16.2 million in year 5.Patient engagement surrounding the topic of continuous glucose monitoring was robust. Patients perceived that these devices provided important social, emotional, and medical and safety benefits in managing type 1 diabetes, especially in children. Continuous glucose monitoring was more effective than self-monitoring of blood glucose in managing type 1 diabetes for some outcomes, such as time spent in the target glucose range and time spent outside the target glucose range (moderate certainty in this evidence). We were less certain that continuous glucose monitoring would reduce the number of severe hypoglycemic events. Compared with self-monitoring of blood glucose, the costs of continuous glucose monitoring were higher, with only small increases in health benefits. Publicly funding continuous glucose monitoring for the type 1 diabetes population in Ontario would result in additional costs to the health system over the next 5 years. Adult patients and parents of children with type 1 diabetes reported very positive experiences with continuous glucose monitoring. The high ongoing cost of continuous glucose monitoring devices was seen as the greatest barrier to their widespread use.
Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment
Vandersluis, Stacey; Kabali, Conrad; Djalalov, Sandjar; Gajic-Veljanoski, Olga; Wells, David; Holubowich, Corinne
2018-01-01
Background Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. Methods We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Results Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0–11.2) to 10.0% (95% confidence interval 6.75–13.25) and decreased the number of severe hypoglycemic events. Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring interventions to usual care. However, the uncertainty around the ICERs was large. The net budget impact of publicly funding continuous glucose monitoring assuming a 20% annual increase in adoption of continuous glucose monitoring would range from $8.5 million in year 1 to $16.2 million in year 5. Patient engagement surrounding the topic of continuous glucose monitoring was robust. Patients perceived that these devices provided important social, emotional, and medical and safety benefits in managing type 1 diabetes, especially in children. Conclusions Continuous glucose monitoring was more effective than self-monitoring of blood glucose in managing type 1 diabetes for some outcomes, such as time spent in the target glucose range and time spent outside the target glucose range (moderate certainty in this evidence). We were less certain that continuous glucose monitoring would reduce the number of severe hypoglycemic events. Compared with self-monitoring of blood glucose, the costs of continuous glucose monitoring were higher, with only small increases in health benefits. Publicly funding continuous glucose monitoring for the type 1 diabetes population in Ontario would result in additional costs to the health system over the next 5 years. Adult patients and parents of children with type 1 diabetes reported very positive experiences with continuous glucose monitoring. The high ongoing cost of continuous glucose monitoring devices was seen as the greatest barrier to their widespread use. PMID:29541282
Batchu, S; Narasimhachar, H; Mayeda, J C; Hall, T; Lopez, J; Nguyen, T; Banister, R E; Lie, D Y C
2017-07-01
Doppler-based non-contact vital signs (NCVS) sensors can monitor heart rates, respiration rates, and motions of patients without physically touching them. We have developed a novel single-board Doppler-based phased-array antenna NCVS biosensor system that can perform robust overnight continuous NCVS monitoring with intelligent automatic subject tracking and optimal beam steering algorithms. Our NCVS sensor achieved overnight continuous vital signs monitoring with an impressive heart-rate monitoring accuracy of over 94% (i.e., within ±5 Beats-Per-Minute vs. a reference sensor), analyzed from over 400,000 data points collected during each overnight monitoring period of ~ 6 hours at a distance of 1.75 meters. The data suggests our intelligent phased-array NCVS sensor can be very attractive for continuous monitoring of low-acuity patients.
Methods for accurate cold-chain temperature monitoring using digital data-logger thermometers
NASA Astrophysics Data System (ADS)
Chojnacky, M. J.; Miller, W. M.; Strouse, G. F.
2013-09-01
Complete and accurate records of vaccine temperature history are vital to preserving drug potency and patient safety. However, previously published vaccine storage and handling guidelines have failed to indicate a need for continuous temperature monitoring in vaccine storage refrigerators. We evaluated the performance of seven digital data logger models as candidates for continuous temperature monitoring of refrigerated vaccines, based on the following criteria: out-of-box performance and compliance with manufacturer accuracy specifications over the range of use; measurement stability over extended, continuous use; proper setup in a vaccine storage refrigerator so that measurements reflect liquid vaccine temperatures; and practical methods for end-user validation and establishing metrological traceability. Data loggers were tested using ice melting point checks and by comparison to calibrated thermocouples to characterize performance over 0 °C to 10 °C. We also monitored logger performance in a study designed to replicate the range of vaccine storage and environmental conditions encountered at provider offices. Based on the results of this study, the Centers for Disease Control released new guidelines on proper methods for storage, handling, and temperature monitoring of vaccines for participants in its federally-funded Vaccines for Children Program. Improved temperature monitoring practices will ultimately decrease waste from damaged vaccines, improve consumer confidence, and increase effective inoculation rates.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What operating parameter monitoring equipment must I install, and what operating parameters must I monitor? 60.3043 Section 60.3043 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What operating parameter monitoring equipment must I install, and what operating parameters must I monitor? 60.2944 Section 60.2944 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Operator...
40 CFR 60.175 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc Smelters § 60.175 Monitoring of operations. (a) The owner or operator of any primary zinc smelter subject...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false How do I establish a valid parameter range if I have chosen to continuously monitor parameters? 60.4410 Section 60.4410 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...
Development and Installation of a Continuous Water Monitoring Systems for the AEDC
1992-08-01
AEDC-TR-92-8 Development and Installation of Continuous Water Monitoring Systems for the AEDC ES Industries 701 South Route 73 Berlin, NJ 08009...Development and Installation of a Continuous Water Monitoring System for the AEDC E AUTHOR(S) Przybyciel, M., Behm, J., and Sampey, T. 7. PERFORMING...Maximum 200 words) A system to sample and analyze water from Rowland Creek at AEDC for hydrocarbon contaminants has been developed under a Small
40 CFR 60.423 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...
40 CFR 60.423 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...
40 CFR 60.423 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...
40 CFR 60.423 - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...
40 CFR 60.423 - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Ammonium Sulfate Manufacture § 60.423 Monitoring of operations. (a) The owner or operator of any ammonium sulfate manufacturing... monitoring devices which can be used to determine the mass flow of ammonium sulfate feed material streams to...
45 CFR 602.40 - Monitoring and reporting program performance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 45 Public Welfare 3 2014-10-01 2014-10-01 false Monitoring and reporting program performance. 602.40 Section 602.40 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE... inspections and certified percentage-of-completion data are relied on heavily by Federal agencies to monitor...
45 CFR 602.40 - Monitoring and reporting program performance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 45 Public Welfare 3 2012-10-01 2012-10-01 false Monitoring and reporting program performance. 602.40 Section 602.40 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE... inspections and certified percentage-of-completion data are relied on heavily by Federal agencies to monitor...
Code of Federal Regulations, 2010 CFR
2010-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is... Performance Specification 1 in appendix B of this part. Complete the evaluation within 60 days after your...
NASA Technical Reports Server (NTRS)
Simon, Donald L.
2010-01-01
Aircraft engine performance trend monitoring and gas path fault diagnostics are closely related technologies that assist operators in managing the health of their gas turbine engine assets. Trend monitoring is the process of monitoring the gradual performance change that an aircraft engine will naturally incur over time due to turbomachinery deterioration, while gas path diagnostics is the process of detecting and isolating the occurrence of any faults impacting engine flow-path performance. Today, performance trend monitoring and gas path fault diagnostic functions are performed by a combination of on-board and off-board strategies. On-board engine control computers contain logic that monitors for anomalous engine operation in real-time. Off-board ground stations are used to conduct fleet-wide engine trend monitoring and fault diagnostics based on data collected from each engine each flight. Continuing advances in avionics are enabling the migration of portions of the ground-based functionality on-board, giving rise to more sophisticated on-board engine health management capabilities. This paper reviews the conventional engine performance trend monitoring and gas path fault diagnostic architecture commonly applied today, and presents a proposed enhanced on-board architecture for future applications. The enhanced architecture gains real-time access to an expanded quantity of engine parameters, and provides advanced on-board model-based estimation capabilities. The benefits of the enhanced architecture include the real-time continuous monitoring of engine health, the early diagnosis of fault conditions, and the estimation of unmeasured engine performance parameters. A future vision to advance the enhanced architecture is also presented and discussed
Method for Continuous Monitoring of Electrospray Ion Formation
NASA Astrophysics Data System (ADS)
Metzler, Guille; Crathern, Susan; Bachmann, Lorin; Fernández-Metzler, Carmen; King, Richard
2017-10-01
A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography-selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. [Figure not available: see fulltext.
40 CFR 63.7505 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance with the applicable emission limit for hydrogen chloride or mercury using fuel analysis if the..., fuel analysis, or continuous monitoring systems (CMS), including a continuous emission monitoring..., you must demonstrate compliance for hydrogen chloride or mercury using performance testing, if subject...
Test/QA Plan for Verification of Semi-Continuous Ambient Air Monitoring Systems - Second Round
Test/QA Plan for Verification of Semi-Continuous Ambient Air Monitoring Systems - Second Round. Changes reflect performance of second round of testing at new location and with various changes to personnel. Additional changes reflect general improvements to the Version 1 test/QA...
40 CFR 63.7952 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... performance tests and performance evaluations as required by § 63.10(b)(2)(viii). (4) The records of initial... your continuous monitoring system. (2) Performance evaluation plans, including previous (i.e... Section 63.7952 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TEST OF DIOXIN EMISSION MONITORS
The performance of four dioxin emission monitors including two long-term sampling devices, the DMS (DioxinMonitoringSystem) and AMESA (Adsorption Method for Sampling Dioxins and Furans), and two semi-real-time continuous monitors, RIMMPA-TOFMS (Resonance Ionization with Multi-Mir...
Ricci, Francesco; Caprio, Felice; Poscia, Alessandro; Valgimigli, Francesco; Messeri, Dimitri; Lepori, Elena; Dall'Oglio, Giorgio; Palleschi, Giuseppe; Moscone, Danila
2007-04-15
Glucose biosensors based on the use of planar screen-printed electrodes modified with an electrochemical mediator and with glucose oxidase have been optimised for their application in the continuous glucose monitoring in diabetic patients. A full study of their operative stability and temperature dependence has been accomplished, thus giving useful information for in vivo applications. The effect of dissolved oxygen concentration in the working solution was also studied in order to evaluate its effect on the linearity of the sensors. Glucose monitoring performed with serum samples was performed to evaluate the effect of matrix components on operative stability and demonstrated an efficient behaviour for 72 h of continuous monitoring. Finally, these studies led to a sensor capable of detecting glucose at concentrations as low as 0.04 mM and with a good linearity up to 2.0 mM (at 37 degrees C) with an operative stability of ca. 72 h, thus demonstrating the possible application of these sensors for continuous glucose monitoring in conjunction with a microdialysis probe. Moreover, preliminary in vivo experiments for ca. 20 h have demonstrated the feasibility of this system.
40 CFR 60.2725 - May I conduct a repeat performance test to establish new operating limits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model... during any performance test used to demonstrate compliance. Model Rule—Monitoring ...
40 CFR 60.2725 - May I conduct a repeat performance test to establish new operating limits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model... during any performance test used to demonstrate compliance. Model Rule—Monitoring ...
... please enable JavaScript. A Holter monitor is a machine that continuously records the heart’s rhythms. The monitor is worn for 24 to 48 hours during normal activity. How the Test is Performed Electrodes (small conducting patches) are stuck ...
INDIRECT MEASUREMENT OF BIOLOGICAL ACTIVITY TO MONITOR NATURAL ATTENUATION
The remediation of ground water contamination by natural attenuation, specifically biodegradation, requires continual monitoring. This research is aimed at improving methods for evaluating the long-term performance of Monitored Natural Attenuation (MNA), specifically changes in ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... human specimens or bacterial growth detected by continuous monitoring blood culture systems. This draft... versus SA in either human specimens or bacterial growth detected by continuous monitoring blood culture... devices that detect MRSA by growth in culture media or those devices that test for the protein, penicillin...
34 CFR 75.118 - Requirements for a continuation award.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wants to receive a continuation award shall submit a performance report that provides the most current performance and financial expenditure information, as directed by the Secretary, that is sufficient to meet... Evaluation by the recipient, § 75.720 Financial and performance reports, § 74.51 Monitoring and reporting...
40 CFR 62.14453 - What must I monitor?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 9 2014-07-01 2014-07-01 false What must I monitor? 62.14453 Section 62.14453 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Performance Testing and Monitoring Requirements § 62.14453 What must I monitor? (a) If your HMIWI uses...
40 CFR 62.14453 - What must I monitor?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 9 2013-07-01 2013-07-01 false What must I monitor? 62.14453 Section 62.14453 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Performance Testing and Monitoring Requirements § 62.14453 What must I monitor? (a) If your HMIWI uses...
40 CFR 63.8810 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... data. Monitoring failures that are caused by poor maintenance or careless operation are not... performance evaluation of each CMS in accordance with your site-specific monitoring plan. (4) You must operate...
7 CFR 3016.40 - Monitoring and reporting program performance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Monitoring and reporting program performance. 3016.40 Section 3016.40 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND COOPERATIVE...
29 CFR 1470.40 - Monitoring and reporting program performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 4 2010-07-01 2010-07-01 false Monitoring and reporting program performance. 1470.40 Section 1470.40 Labor Regulations Relating to Labor (Continued) FEDERAL MEDIATION AND CONCILIATION SERVICE... not met. (iii) Additional pertinent information including, when appropriate, analysis and explanation...
Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses.
Ascaso, Francisco J; Huerva, Valentín
2016-04-01
: The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.
40 CFR 60.1820 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false How do I monitor the injection rate of activated carbon? 60.1820 Section 60.1820 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal...
40 CFR 60.1820 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false How do I monitor the injection rate of activated carbon? 60.1820 Section 60.1820 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal...
40 CFR 60.1820 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false How do I monitor the injection rate of activated carbon? 60.1820 Section 60.1820 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal...
40 CFR 60.1820 - How do I monitor the injection rate of activated carbon?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false How do I monitor the injection rate of activated carbon? 60.1820 Section 60.1820 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal...
40 CFR 60.2865 - How must I monitor opacity for air curtain incinerators?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false How must I monitor opacity for air curtain incinerators? 60.2865 Section 60.2865 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and...
40 CFR 60.2865 - How must I monitor opacity for air curtain incinerators?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false How must I monitor opacity for air curtain incinerators? 60.2865 Section 60.2865 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and...
Code of Federal Regulations, 2010 CFR
2010-07-01
...—Requirements for Continuous Emission Monitoring Systems (CEMS) For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for your CEMS If needed to meet minimum data requirements, use the folloiwng alternate methods in appendix A of...
Code of Federal Regulations, 2011 CFR
2011-07-01
...—Requirements for Continuous Emission Monitoring Systems (CEMS) For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for your CEMS If needed to meet minimum data requirements, use the folloiwng alternate methods in appendix A of...
NASA Technical Reports Server (NTRS)
Wilson, Deborah M.
2015-01-01
This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The next performance monitoring event is scheduled for July 2015.
7 CFR 3015.91 - Monitoring by recipients.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Monitoring by recipients. 3015.91 Section 3015.91 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Monitoring and Reporting Program Performance...
McLean, Thomas D; Moore, Murray E; Justus, Alan L; Hudston, Jonathan A; Barbé, Benoît
2016-11-01
Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. The Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch's minute hand, and as it rotates, more of the underlying source is revealed. The measured alpha activity increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. Data obtained using the Dynamic Radioactive Source has been used to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.
McLean, Thomas D.; Moore, Murray E.; Justus, Alan L.; ...
2016-01-01
Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached tomore » the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.« less
Integrated photovoltaic (PV) monitoring system
NASA Astrophysics Data System (ADS)
Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti
2012-09-01
The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.
Blood Glucose Monitoring Devices
... of interferences ability to transmit data to a computer cost of the meter cost of the test ... Performance FDA expands indication for continuous glucose monitoring system, first to replace fingerstick testing for diabetes treatment ...
Evaluation of High-Precision Sensors in Structural Monitoring
Erol, Bihter
2010-01-01
One of the most intricate branches of metrology involves the monitoring of displacements and deformations of natural and anthropogenic structures under environmental forces, such as tidal or tectonic phenomena, or ground water level changes. Technological progress has changed the measurement process, and steadily increasing accuracy requirements have led to the continued development of new measuring instruments. The adoption of an appropriate measurement strategy, with proper instruments suited for the characteristics of the observed structure and its environmental conditions, is of high priority in the planning of deformation monitoring processes. This paper describes the use of precise digital inclination sensors in continuous monitoring of structural deformations. The topic is treated from two viewpoints: (i) evaluation of the performance of inclination sensors by comparing them to static and continuous GPS observations in deformation monitoring and (ii) providing a strategy for analyzing the structural deformations. The movements of two case study objects, a tall building and a geodetic monument in Istanbul, were separately monitored using dual-axes micro-radian precision inclination sensors (inclinometers) and GPS. The time series of continuous deformation observations were analyzed using the Least Squares Spectral Analysis Technique (LSSA). Overall, the inclinometers showed good performance for continuous monitoring of structural displacements, even at the sub-millimeter level. Static GPS observations remained insufficient for resolving the deformations to the sub-centimeter level due to the errors that affect GPS signals. With the accuracy advantage of inclination sensors, their use with GPS provides more detailed investigation of deformation phenomena. Using inclinometers and GPS is helpful to be able to identify the components of structural responses to the natural forces as static, quasi-static, or resonant. PMID:22163499
NASA Astrophysics Data System (ADS)
Lee, Seung Yup; Pakela, Julia M.; Hedrick, Taylor L.; Vishwanath, Karthik; Helton, Michael C.; Chung, Yooree; Kolodziejski, Noah J.; Stapels, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann
2017-02-01
In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.
Lens-free shadow image based high-throughput continuous cell monitoring technique.
Jin, Geonsoo; Yoo, In-Hwa; Pack, Seung Pil; Yang, Ji-Woon; Ha, Un-Hwan; Paek, Se-Hwan; Seo, Sungkyu
2012-01-01
A high-throughput continuous cell monitoring technique which does not require any labeling reagents or destruction of the specimen is demonstrated. More than 6000 human alveolar epithelial A549 cells are monitored for up to 72 h simultaneously and continuously with a single digital image within a cost and space effective lens-free shadow imaging platform. In an experiment performed within a custom built incubator integrated with the lens-free shadow imaging platform, the cell nucleus division process could be successfully characterized by calculating the signal-to-noise ratios (SNRs) and the shadow diameters (SDs) of the cell shadow patterns. The versatile nature of this platform also enabled a single cell viability test followed by live cell counting. This study firstly shows that the lens-free shadow imaging technique can provide a continuous cell monitoring without any staining/labeling reagent and destruction of the specimen. This high-throughput continuous cell monitoring technique based on lens-free shadow imaging may be widely utilized as a compact, low-cost, and high-throughput cell monitoring tool in the fields of drug and food screening or cell proliferation and viability testing. Copyright © 2012 Elsevier B.V. All rights reserved.
The semi-continuous Monitor for AeRosols and Gases in Ambient air (MARGA) was evaluated using laboratory and field data with a focus on chromatography. The performance and accuracy assessment revealed various errors and uncertainties resulting from mis-identification and mis-int...
The semi-continuous Monitor for AeRosols and Gases in Ambient air (MARGA) was evaluated using laboratory and field data with a focus on chromatography. The performance and accuracy assessment revealed various errors and uncertainties resulting from mis-identification and mis-int...
40 CFR 60.203 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate..., calibrate, maintain, and operate a monitoring device which can be used to determine the mass flow of... maintain a daily record of equivalent P2O5 feed by first determining the total mass rate in Mg/hr of...
Field evaluation of Fourier transform infrared continuous emissions monitoring (FTIR CEM) systems
NASA Astrophysics Data System (ADS)
Dunder, Thomas A.; Geyer, Thomas J.; Kinner, Laura L.; Plummer, Grant M.
1995-02-01
Recent environmental regulations, including the Clean Air Act and the Enhanced Monitoring Regulations, may require continuous emissions monitoring (CEM) of hazardous air pollutants (HAPs). A promising technique for this application is Fourier transform infrared spectroscopy (FTIR). FTIR spectroscopy can, in principle, be used to monitor virtually any gas phase species. Two evaluations of FTIR CEM systems are discussed. The first study, performed in 1993 - 94, compared two FTIR CEM systems on a side-by-side basis in an extended field test at two coal-fired electric power plants. The FTIR CEM systems monitored the legally mandated criteria pollutants and diluents (CO, CO2, NO, NO2, and SO2) as well as H2O. In addition, one system monitored two HAPs (HCl and HF) and NH3. The FTIR CEM measurements were compared with those from the compliance CEM systems at the facilities. Several relative accuracy test audits were also performed to verify the FTIR CEM accuracy. The second evaluation was recently commenced on behalf of the Environmental Protection Agency. In this study, FTIR CEM systems are evaluated specifically for the monitoring of HAP species by conducting laboratory and field tests. The evaluation culminates in the development of proposed performance specifications and protocols for FTIR CEM systems.
A hydrogen fuel cell for rapid, enzyme-catalysed organic synthesis with continuous monitoring.
Wan, Lei; Megarity, Clare F; Siritanaratkul, Bhavin; Armstrong, Fraser A
2018-01-23
A one-pot fuel cell for specific, enzyme-catalysed organic synthesis, with continuous monitoring of rate and reaction progress, combines an electrode catalysing rapid, reversible and diffusion-controlled interconversion of NADP + and NADPH with a Pt electrode catalysing 2H + /H 2 interconversion. This Communication demonstrates its performance and characteristics using the reductive amination of 2-oxoglutarate as a test system.
SNAP 19 Viking Program. Bimonthly technical progress report, October 1979-November 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-12-01
Monitoring and evaluation of Viking 1 Lander power system data continued. The RTG series power range as measured at the PCDA was 65 to 68 watts at fin root temperatures between 280/sup 0/F and 310/sup 0/F. The Mars landed performance history of Viking 1 include both the minimum and maximum data for each of the SOL days. Monitoring and evaluation of Viking 2 Lander power system data continued. The RTG series power range as measured at the PCDA was 71 to 72 watts at fin root temperatures between 230/sup 0/F and 260/sup 0/F. The Mars landed performance history of Vikingmore » 2 include both the minimum and maximum data for each of the SOL days. The performance of both power systems continues to be very satisfactory. Power system performance data for Pioneer 10 and Pioneer 11 spacecraft were monitored through the reporting period. The estimated RTG system net power was 116 watts for Pioneer 10 and 118 watts for Pioneer Saturn. The September 1 encounter with Saturn appears to have had no deleterious effect on the RTG's of the spacecraft power system. The telemetry signals from both spacecrafts remain satisfactory.« less
Novel optoacoustic system for noninvasive continuous monitoring of cerebral venous blood oxygenation
NASA Astrophysics Data System (ADS)
Petrov, Yuriy; Petrov, Irene Y.; Prough, Donald S.; Esenaliev, Rinat O.
2012-02-01
Traumatic brain injury (TBI) and spinal cord injury are a major cause of death for individuals under 50 years of age. In the USA alone, 150,000 patients per year suffer moderate or severe TBI. Moreover, TBI is a major cause of combatrelated death. Monitoring of cerebral venous blood oxygenation is critically important for management of TBI patients because cerebral venous blood oxygenation below 50% results in death or severe neurologic complications. At present, there is no technique for noninvasive, accurate monitoring of this clinically important variable. We proposed to use optoacoustic technique for noninvasive monitoring of cerebral venous blood oxygenation by probing cerebral veins such as the superior sagittal sinus (SSS) and validated it in animal studies. In this work, we developed a novel, medical grade optoacoustic system for continuous, real-time cerebral venous blood oxygenation monitoring and tested it in human subjects at normal conditions and during hyperventilation to simulate changes that may occur in patients with TBI. We designed and built a highly-sensitive optoacoustic probe for SSS signal detection. Continuous measurements were performed in the near infrared spectral range and the SSS oxygenation absolute values were automatically calculated in real time using a special algorithm developed by our group. Continuous measurements performed at normal conditions and during hyperventilation demonstrated that hyperventilation resulted in approximately 12% decrease of cerebral venous blood oxygenation.
40 CFR 60.2865 - How must I monitor opacity for air curtain incinerators?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Air...
ERIC Educational Resources Information Center
Miller, Steven E.; Seiberling, Chris
2004-01-01
This article represents the second part of a series in this journal called "How to Perform a Security Audit." It continues the conversation on setting up a process for identifying security-related concerns and implementation safeguards. It continues the conversation from the perspective of system monitoring. This article discusses how to use a…
NASA Astrophysics Data System (ADS)
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Continuous glucose monitoring in acute coronary syndrome.
Rodríguez-Quintanilla, Karina Alejandra; Lavalle-González, Fernando Javier; Mancillas-Adame, Leonardo Guadalupe; Zapata-Garrido, Alfonso Javier; Villarreal-Pérez, Jesús Zacarías; Tamez-Pérez, Héctor Eloy
2013-01-01
Diabetes mellitus is an independent risk factor for cardiovascular disease. To compare the efficacy of devices for continuous glucose monitoring and capillary glucose monitoring in hospitalized patients with acute coronary syndrome using the following parameters: time to achieve normoglycemia, period of time in normoglycemia, and episodes of hypoglycemia. We performed a pilot, non-randomized, unblinded clinical trial that included 16 patients with acute coronary artery syndrome, a capillary or venous blood glucose ≥ 140 mg/dl, and treatment with a continuous infusion of fast acting human insulin. These patients were randomized into 2 groups: a conventional group, in which capillary measurement and recording as well as insulin adjustment were made every 4h, and an intervention group, in which measurement and recording as well as insulin adjustment were made every hour with a subcutaneous continuous monitoring system. Student's t-test was applied for mean differences and the X(2) test for qualitative variables. We observed a statistically significant difference in the mean time for achieving normoglycemia, favoring the conventional group with a P = 0.02. Continuous monitoring systems are as useful as capillary monitoring for achieving normoglycemia. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Integrated monitoring technologies for the management of a Soil-Aquifer-Treatment (SAT) system.
NASA Astrophysics Data System (ADS)
Papadopoulos, Alexandros; Kallioras, Andreas; Kofakis, Petros; Bumberger, Jan; Schmidt, Felix; Athanasiou, Georgios; Uzunoglou, Nikolaos; Amditis, Angelos; Dietrich, Peter
2016-04-01
Artificial recharge of groundwater has an important role to play in water reuse as treated wastewater effluent can be infiltrated into the ground for aquifer recharge. As the effluent moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. The pilot site of Lavrion Technological & Cultural Park (LTCP) of the National Technical University of Athens (NTUA), involves the employment of plot infiltration basins at experimental scale, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. Τhe LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved by the development and installation of an integrated system of prototype sensing technologies, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time and Frequency Domain Reflectometry (TDR & FDR) sensors is developed and will be installed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. Additionally, the system contains two different radar-based sensing systems that will be offering (i) identification of preferential flow effects of the TDR/FDR sensors and (ii) monitoring of the water table within the shallow karst aquifer layer. The above technique will offer continuous monitoring of infiltration rates and identify possible mechanical or biological clogging effects. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.
40 CFR 60.544 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Rubber Tire... organic compounds based on a detection principle such as infrared, photoionization, or thermal...
ST-segment monitoring: putting standards into practice.
Flanders, Sonya A
2007-01-01
ST-segment monitoring is one key reason that continuous electrocardiographic monitoring is performed in hospitals, and can help with early detection of myocardial ischemia for at-risk patients. Although ST-segment monitoring research, guidelines, and expert consensus statements have been published, ST-segment monitoring has not been implemented in all appropriate clinical areas. The purpose of this article is to present relevant research, review the latest practice standards, and discuss issues important to nurses wishing to implement ST-segment monitoring.
NASA Astrophysics Data System (ADS)
Kallioras, Andreas; Tsertou, Athanasia; Foglia, Laura; Bumberger, Jan; Vienken, Thomas; Dietrich, Peter; Schüth, Christoph
2014-05-01
Artificial recharge of groundwater has an important role to play in water reuse. Treated sewage effluent can be infiltrated into the ground for recharge of aquifers. As the effluent water moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. Recharge systems for SAT can be designed as infiltration-recovery systems, where all effluent water is recovered as such from the aquifer, or after blending with native groundwater. SAT typically removes essentially all suspended solids, biochemical oxygen demand (BOD), and pathogens (viruses, bacteria, protozoa, and helminthic eggs). Concentrations of synthetic organic carbon, phosphorous, and heavy metals are greatly reduced. The pilot site of LTCP will involve the employment of infiltration basins, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. T he LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved through the development and installation of an integrated system of prototype sensors, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time Domain Reflectometry (TDR) sensors will be developed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. The above technique will offer continuous monitoring of infiltration rates and possible mechanical clogging effects. The qualitative monitoring of the unsaturated zone will be achieved through the installation of appropriate pore-water samplers within a multi-level basis, ensuring repeatability of sampling of infiltrating water of impaired quality. This study also involves the qualitative and quantitative assessment of the Lavrion multi-aquifer system through continuous monitoring of the performance of (i) the alluvial aquifer and its potential for additional water treatment as well as (ii) the effects of the SAT system for countermeasuring seawater intrusion in the area of Lavrion. Additionally, setup and calibration of numerical flow and transport models for evaluating and optimizing different operational modes of the SAT system within both saturated and unsaturated zones will be conducted. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.
Hall, Travis; Nguyen, Tam Q.; Mayeda, Jill C.; Lie, Paul E.; Lopez, Jerry; Banister, Ron E.
2017-01-01
It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients’ long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient’s vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping without hectic movements nearby. PMID:29140281
Hall, Travis; Lie, Donald Y C; Nguyen, Tam Q; Mayeda, Jill C; Lie, Paul E; Lopez, Jerry; Banister, Ron E
2017-11-15
It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients' long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient's vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping without hectic movements nearby.
Code of Federal Regulations, 2011 CFR
2011-07-01
... evaluation, you must collect the appropriate operating parameter monitoring system data, average the... 760 °C or higher. (f) You must conduct a performance evaluation for each continuous monitoring system... Level 1 controls, § 63.1063(d) for Tank Level 2 controls, § 63.926(a) for Container Level 1 controls...
Code of Federal Regulations, 2013 CFR
2013-07-01
... evaluation, you must collect the appropriate operating parameter monitoring system data, average the... 760 °C or higher. (f) You must conduct a performance evaluation for each continuous monitoring system... Level 1 controls, § 63.1063(d) for Tank Level 2 controls, § 63.926(a) for Container Level 1 controls...
Code of Federal Regulations, 2012 CFR
2012-07-01
... evaluation, you must collect the appropriate operating parameter monitoring system data, average the... 760 °C or higher. (f) You must conduct a performance evaluation for each continuous monitoring system... Level 1 controls, § 63.1063(d) for Tank Level 2 controls, § 63.926(a) for Container Level 1 controls...
Van den Bosch, Kyle; Matthews, Jeffrey W
2017-04-01
Under the US Clean Water Act, wetland restoration is used to compensate for adverse impacts to wetlands. Following construction, compensation wetlands are monitored for approximately 5 years to determine if they comply with project-specific performance standards. Once a compensation site complies with performance standards, it is assumed that the site will continue to meet standards indefinitely. However, there have been few assessments of long-term compliance. We surveyed, in 2012, 30 compensation sites 8-20 years after restoration to determine whether projects continued to meet performance standards. Additionally, we compared floristic quality of compensation sites to the quality of adjacent natural wetlands to determine whether wetland condition in compensation sites could be predicted based on the condition of nearby wetlands. Compensation sites met, on average, 65% of standards during the final year of monitoring and 53% of standards in 2012, a significant decrease in compliance. Although forested wetlands often failed to meet standards for planted tree survival, the temporal decrease in compliance was driven by increasing dominance by invasive plants in emergent wetlands. The presumption of continued compliance with performance standards after a 5-year monitoring period was not supported. Wetlands restored near better quality natural wetlands achieved and maintained greater floristic quality, suggesting that landscape context was an important determinant of long-term restoration outcomes. Based on our findings, we recommend that compensation wetlands should be monitored for longer time periods, and we suggest that nearby or adjacent natural wetlands provide good examples of reasonably achievable restoration outcomes in a particular landscape.
Glance strategies for using an in-vehicle touch-screen monitor.
DOT National Transportation Integrated Search
2009-04-01
In this study, subjects in a driving simulator followed a lead vehicle that continuously changed speed : while they also performed a secondary task on a touch-screen monitor that could be located at various : positions within the simulator. Subjects ...
Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu
2018-01-01
We present a high throughput crop physiology condition monitoring system and corresponding monitoring method. The monitoring system can perform large-area chlorophyll fluorescence imaging and multispectral imaging. The monitoring method can determine the crop current condition continuously and non-destructively. We choose chlorophyll fluorescence parameters and relative reflectance of multispectral as the indicators of crop physiological status. Using tomato as experiment subject, the typical crop physiological stress, such as drought, nutrition deficiency and plant disease can be distinguished by the monitoring method. Furthermore, we have studied the correlation between the physiological indicators and the degree of stress. Besides realizing the continuous monitoring of crop physiology, the monitoring system and method provide the possibility of machine automatic diagnosis of the plant physiology. Highlights: A newly designed high throughput crop physiology monitoring system and the corresponding monitoring method are described in this study. Different types of stress can induce distinct fluorescence and spectral characteristics, which can be used to evaluate the physiological status of plants.
40 CFR 60.143 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...
40 CFR 60.143 - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...
40 CFR 60.143 - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... which the affected facility demonstrated compliance with the mass standards under § 60.142(a)(1), (b)(1... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary...
PACS administrators' and radiologists' perspective on the importance of features for PACS selection.
Joshi, Vivek; Narra, Vamsi R; Joshi, Kailash; Lee, Kyootai; Melson, David
2014-08-01
Picture archiving and communication systems (PACS) play a critical role in radiology. This paper presents the criteria important to PACS administrators for selecting a PACS. A set of criteria are identified and organized into an integrative hierarchical framework. Survey responses from 48 administrators are used to identify the relative weights of these criteria through an analytical hierarchy process. The five main dimensions for PACS selection in order of importance are system continuity and functionality, system performance and architecture, user interface for workflow management, user interface for image manipulation, and display quality. Among the subdimensions, the highest weights were assessed for security, backup, and continuity; tools for continuous performance monitoring; support for multispecialty images; and voice recognition/transcription. PACS administrators' preferences were generally in line with that of previously reported results for radiologists. Both groups assigned the highest priority to ensuring business continuity and preventing loss of data through features such as security, backup, downtime prevention, and tools for continuous PACS performance monitoring. PACS administrators' next high priorities were support for multispecialty images, image retrieval speeds from short-term and long-term storage, real-time monitoring, and architectural issues of compatibility and integration with other products. Thus, next to ensuring business continuity, administrators' focus was on issues that impact their ability to deliver services and support. On the other hand, radiologists gave high priorities to voice recognition, transcription, and reporting; structured reporting; and convenience and responsiveness in manipulation of images. Thus, radiologists' focus appears to be on issues that may impact their productivity, effort, and accuracy.
Continuous intra-arterial blood-gas monitoring
NASA Astrophysics Data System (ADS)
Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.
1993-05-01
Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.
Bearg, D W
1998-09-01
This article summarizes an approach for improving the indoor air quality (IAQ) in a building by providing feedback on the performance of the ventilation system. The delivery of adequate quantities of ventilation to all building occupants is necessary for the achievement of good IAQ. Feedback on the performance includes information on the adequacy of ventilation provided, the effectiveness of the distribution of this air, the adequacy of the duration of operation of the ventilation system, and the identification of leakage into the return plenum, either of outdoor or supply air. Keeping track of ventilation system performance is important not only in terms of maintaining good IAQ, but also making sure that this system continues to perform as intended after changes in building use. Information on the performance of the ventilation system is achieved by means of an automated sampling system that draws air from multiple locations and delivers it to both a carbon dioxide monitor and dew point sensor. The use of single shared sensors facilitates calibration checks as well as helps to guarantee data integrity. This approach to monitoring a building's ventilation system offers the possibility of achieving sustainable performance of this important aspect of good IAQ.
Hanford Site ground-water monitoring for 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dresel, P.E.; Luttrell, S.P.; Evans, J.C.
This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1993 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1993 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporatedmore » to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1992 and June 1993. The greatest declines occurred in the 200-West Area. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal. Water levels remained nearly constant in the vicinity of B Pond, as a result of continued disposal to the pond. Water levels measured from wells in the unconfined aquifer north and east of the Columbia River indicate that the primary source of recharge is irrigation practices.« less
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media.
Ghaffari, Seyed Alireza; Caron, William-O; Loubier, Mathilde; Normandeau, Charles-O; Viens, Jeff; Lamhamedi, Mohammed S; Gosselin, Benoit; Messaddeq, Younes
2015-07-21
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3- in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications.
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media
Ghaffari, Seyed Alireza; Caron, William-O.; Loubier, Mathilde; Normandeau, Charles-O.; Viens, Jeff; Lamhamedi, Mohammed S.; Gosselin, Benoit; Messaddeq, Younes
2015-01-01
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3− in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications. PMID:26197322
NASA Astrophysics Data System (ADS)
Lösler, Michael; Haas, Rüdiger; Eschelbach, Cornelia
2013-08-01
The Global Geodetic Observing System (GGOS) requires sub-mm accuracy, automated and continual determinations of the so-called local tie vectors at co-location stations. Co-location stations host instrumentation for several space geodetic techniques and the local tie surveys involve the relative geometry of the reference points of these instruments. Thus, these reference points need to be determined in a common coordinate system, which is a particular challenge for rotating equipment like radio telescopes for geodetic Very Long Baseline Interferometry. In this work we describe a concept to achieve automated and continual determinations of radio telescope reference points with sub-mm accuracy. We developed a monitoring system, including Java-based sensor communication for automated surveys, network adjustment and further data analysis. This monitoring system was tested during a monitoring campaign performed at the Onsala Space Observatory in the summer of 2012. The results obtained in this campaign show that it is possible to perform automated determination of a radio telescope reference point during normal operations of the telescope. Accuracies on the sub-mm level can be achieved, and continual determinations can be realized by repeated determinations and recursive estimation methods.
The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techn...
10 CFR 61.53 - Environmental monitoring.
Code of Federal Regulations, 2010 CFR
2010-01-01
... NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.53 Environmental monitoring. (a) At the time a... radionuclides would indicate that the performance objectives of subpart C may not be met. (c) During the land...
10 CFR 61.53 - Environmental monitoring.
Code of Federal Regulations, 2012 CFR
2012-01-01
... NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.53 Environmental monitoring. (a) At the time a... radionuclides would indicate that the performance objectives of subpart C may not be met. (c) During the land...
10 CFR 61.53 - Environmental monitoring.
Code of Federal Regulations, 2013 CFR
2013-01-01
... NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.53 Environmental monitoring. (a) At the time a... radionuclides would indicate that the performance objectives of subpart C may not be met. (c) During the land...
10 CFR 61.53 - Environmental monitoring.
Code of Federal Regulations, 2014 CFR
2014-01-01
... NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.53 Environmental monitoring. (a) At the time a... radionuclides would indicate that the performance objectives of subpart C may not be met. (c) During the land...
10 CFR 61.53 - Environmental monitoring.
Code of Federal Regulations, 2011 CFR
2011-01-01
... NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.53 Environmental monitoring. (a) At the time a... radionuclides would indicate that the performance objectives of subpart C may not be met. (c) During the land...
AMON: a wearable multiparameter medical monitoring and alert system.
Anliker, Urs; Ward, Jamie A; Lukowicz, Paul; Tröster, Gerhard; Dolveck, François; Baer, Michel; Keita, Fatou; Schenker, Eran B; Catarsi, Fabrizio; Coluccini, Luca; Belardinelli, Andrea; Shklarski, Dror; Alon, Menachem; Hirt, Etienne; Schmid, Rolf; Vuskovic, Milica
2004-12-01
This paper describes an advanced care and alert portable telemedical monitor (AMON), a wearable medical monitoring and alert system targeting high-risk cardiac/respiratory patients. The system includes continuous collection and evaluation of multiple vital signs, intelligent multiparameter medical emergency detection, and a cellular connection to a medical center. By integrating the whole system in an unobtrusive, wrist-worn enclosure and applying aggressive low-power design techniques, continuous long-term monitoring can be performed without interfering with the patients' everyday activities and without restricting their mobility. In the first two and a half years of this EU IST sponsored project, the AMON consortium has designed, implemented, and tested the described wrist-worn device, a communication link, and a comprehensive medical center software package. The performance of the system has been validated by a medical study with a set of 33 subjects. The paper describes the main concepts behind the AMON system and presents details of the individual subsystems and solutions as well as the results of the medical validation.
Kabali, Conrad; Xie, Xuanqian; Higgins, Caroline
2017-01-01
Background Ambulatory electrocardiography (ECG) monitors are often used to detect cardiac arrhythmia. For patients with symptoms, an external cardiac loop recorder will often be recommended. The improved recording capacity of newer Holter monitors and similar devices, collectively known as longterm continuous ambulatory ECG monitors, suggests that they will perform just as well as, or better than, external loop recorders. This health technology assessment aimed to evaluate the effectiveness, cost-effectiveness, and budget impact of longterm continuous ECG monitors compared with external loop recorders in detecting symptoms of cardiac arrhythmia. Methods Based on our systematic search for studies published up to January 15, 2016, we did not identify any studies directly comparing the clinical effectiveness of longterm continuous ECG monitors and external loop recorders. Therefore, we conducted an indirect comparison, using a 24-hour Holter monitor as a common comparator. We used a meta-regression model to control for bias due to variation in device-wearing time and baseline syncope rate across studies. We conducted a similar systematic search for cost-utility and cost-effectiveness studies comparing the two types of devices; none were found. Finally, we used historical claims data (2006–2014) to estimate the future 5-year budget impact in Ontario, Canada, of continued public funding for both types of longterm ambulatory ECG monitors. Results Our clinical literature search yielded 7,815 non-duplicate citations, of which 12 cohort studies were eligible for indirect comparison. Seven studies assessed the effectiveness of longterm continuous monitors and five assessed external loop recorders. Both types of devices were more effective than a 24-hour Holter monitor, and we found no substantial difference between them in their ability to detect symptoms (risk difference 0.01; 95% confidence interval −0.18, 0.20). Using GRADE for network meta-analysis, we evaluated the quality of the evidence as low. Our budget impact analysis showed that use of the longterm continuous monitors has grown steadily in Ontario since they became publicly funded in 2006, particularly since 2011 when monitors that can record for 14 days or longer became funded, and the use of external cardiac loop recorders has correspondingly declined. The analysis suggests that, with these trends, continued public funding of both types of longterm ambulatory ECG testing will result in additional costs ranging from $130,000 to $370,000 per year over the next 5 years. Conclusions Although both longterm continuous ambulatory ECG monitors and external cardiac loop recorders were more effective than a 24-hour Holter monitor in detecting symptoms of cardiac arrhythmia, we found no evidence to suggest that these two devices differ in effectiveness. Assuming that the use of longterm continuous monitors will continue to increase in the next 5 years, the public health care system in Ontario can expect to see added costs of $130,000 to $370,000 per year. PMID:28194254
Development of Sesquioxide Ceramic for High Energy Lasers
2015-05-25
CSJ308 , Mutsuno, Atsuta- ku Nagoya 456-0023 Japan 8. PERFORMING ORGANIZATION REPORT NUMBER N/A 9. SPONSORING/MONITORING AGENCY NAME...Labo Co., Ltd.,1-2-19-CSJ308 , Mutsuno, Atsuta- ku ,Nagoya 456-0023,Japan,NA,NA 8. PERFORMING ORGANIZATION REPORT NUMBER N/A 9. SPONSORING/MONITORING...Huang, D. Shen , J. Zhang, H. Chen, Y. Wang, X. Liu, D. Tang, “Room Temperature Continuous-wave Laser Performance of LD Pumped Er:Lu2O3 and Er:Y2O3
40 CFR 63.7191 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... malfunctions. (3) Records of performance tests and performance evaluations as required in § 63.10(b)(2)(viii... measurements, raw performance evaluation measurements). (3) All required CMS measurements (including monitoring... Section 63.7191 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR Appendix A to Subpart F of... - References
Code of Federal Regulations, 2010 CFR
2010-07-01
... Indoor Air Sampling: Design and Calibration., JAPCA, 37: 1303-1307 (1987). (2) Vanderpool, R.W. and K.L... Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Performance Characteristics...
40 CFR Appendix A to Subpart F of... - References
Code of Federal Regulations, 2011 CFR
2011-07-01
... Indoor Air Sampling: Design and Calibration., JAPCA, 37: 1303-1307 (1987). (2) Vanderpool, R.W. and K.L... Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Performance Characteristics...
Belliato, Mirko; Degani, Antonella; Buffa, Antonino; Sciutti, Fabio; Pagani, Michele; Pellegrini, Carlo; Iotti, Giorgio Antonio
2017-10-01
Monitoring veno-venous extracorporeal membrane oxygenation (vvECMO) during 76 days of continuous support in a 42-years old patient with end-stage pulmonary disease, listed for double-lung transplantation. Applying a new monitor (Landing ® , Eurosets, Medolla, Italy) and describing how measured and calculated parameters can be used to understand the variable interdependency between artificial membrane lung (ML) and patient native lung (NL). During vvECMO, in order to understand how the respiratory function is shared between ML and NL, ideally we should obtain data about oxygen transfer and CO 2 removal, both by ML and NL. Measurements for NL can be made on the mechanical ventilator. Measurements for ML are typically made from gas analysis on blood samples drawn from the ECMO system before and after the oxygenator, and therefore are non-continuous. Differently, the Landing monitor provides a continuous measurement of the oxygen transfer from the ML, combined with hemoglobin level, saturation of drained blood and saturation of reinfused blood. Moreover, the Landing monitor provides hemodynamics data about circulation through the ECMO system, with blood flow, pre-oxygenator pressure and post-oxygenator pressure. Of note, measurements include the drain negative pressure, whose monitoring may be particularly useful to prevent hemolysis. Real-time monitoring of vvECMO provides data helpful to understand the complex picture of a patient with severely damaged lungs on one side and an artificial lung on the other side. Data from vvECMO monitoring may help to adapt the settings of both mechanical ventilator and vvECMO. Data about oxygen transfer by the oxygenator are important to evaluate the performance of the device and may help to avoid unnecessary replacements, thus reducing risks and costs.
Towards the Automatic Classification of Avian Flight Calls for Bioacoustic Monitoring
Bello, Juan Pablo; Farnsworth, Andrew; Robbins, Matt; Keen, Sara; Klinck, Holger; Kelling, Steve
2016-01-01
Automatic classification of animal vocalizations has great potential to enhance the monitoring of species movements and behaviors. This is particularly true for monitoring nocturnal bird migration, where automated classification of migrants’ flight calls could yield new biological insights and conservation applications for birds that vocalize during migration. In this paper we investigate the automatic classification of bird species from flight calls, and in particular the relationship between two different problem formulations commonly found in the literature: classifying a short clip containing one of a fixed set of known species (N-class problem) and the continuous monitoring problem, the latter of which is relevant to migration monitoring. We implemented a state-of-the-art audio classification model based on unsupervised feature learning and evaluated it on three novel datasets, one for studying the N-class problem including over 5000 flight calls from 43 different species, and two realistic datasets for studying the monitoring scenario comprising hundreds of thousands of audio clips that were compiled by means of remote acoustic sensors deployed in the field during two migration seasons. We show that the model achieves high accuracy when classifying a clip to one of N known species, even for a large number of species. In contrast, the model does not perform as well in the continuous monitoring case. Through a detailed error analysis (that included full expert review of false positives and negatives) we show the model is confounded by varying background noise conditions and previously unseen vocalizations. We also show that the model needs to be parameterized and benchmarked differently for the continuous monitoring scenario. Finally, we show that despite the reduced performance, given the right conditions the model can still characterize the migration pattern of a specific species. The paper concludes with directions for future research. PMID:27880836
Code of Federal Regulations, 2010 CFR
2010-07-01
...-gas ratio above the limit established during the performance test. 4. Option 3: Ni lb/hr not subject to the NSPS for PM in 40 CFR 60.102. a. Continuous opacity monitoring system. The daily average Ni operating value must not exceed the site-specific Ni operating limit established during the performance test...
Code of Federal Regulations, 2011 CFR
2011-07-01
...-gas ratio above the limit established during the performance test. 4. Option 3: Ni lb/hr not subject to the NSPS for PM in 40 CFR 60.102. a. Continuous opacity monitoring system. The daily average Ni operating value must not exceed the site-specific Ni operating limit established during the performance test...
Puls, R W; Blowes, D W; Gillham, R W
1999-08-12
A continuous hanging iron wall was installed in June, 1996, at the U. S. Coast Guard (USCG) Support Center near Elizabeth City, NC, United States, to treat overlapping plumes of chromate and chlorinated solvent compounds. The wall was emplaced using a continuous trenching machine whereby native soil and aquifer sediment was removed and the iron simultaneously emplaced in one continuous excavation and fill operation. To date, there have been seven rounds (November 1996, March 1997, June 1997, September 1997, December 1997, March 1998, and June 1998) of performance monitoring of the wall. At this time, this is the only full-scale continuous 'hanging' wall installed as a permeable reactive barrier to remediate both chlorinated solvent compounds and chromate in groundwater. Performance monitoring entails the following: sampling of 10-5 cm PVC compliance wells and 15 multi-level samplers for the following constituents: TCE, cis-dichloroethylene (c-DCE), vinyl chloride, ethane, ethene, acetylene, methane, major anions, metals, Cr(VI), Fe(II), total sulfides, dissolved H(2), Eh, pH, dissolved oxygen, specific conductance, alkalinity, and turbidity. Electrical conductivity profiles have been conducted using a Geoprobe to verify emplacement of the continuous wall as designed and to locate upgradient and downgradient wall interfaces for coring purposes. Coring has been conducted in November, 1996, in June and September, 1997, and March, 1998, to evaluate the rate of corrosion on the iron surfaces, precipitate buildup (particularly at the upgradient interface), and permeability changes due to wall emplacement. In addition to several continuous vertical cores, angled cores through the 0.6-m thick wall have been collected to capture upgradient and downgradient wall interfaces along approximate horizontal flow paths for mineralogic analyses.
[Recommendations for the evaluation and follow-up of the continuous quality improvement].
Maurellet-Evrard, S; Daunizeau, A
2013-06-01
Continual improvement of the quality in a medical laboratory is based on the implementation of tools for systematically evaluate the quality management system and its ability to meet the objectives defined. Monitoring through audit and management review, addressing complaints and nonconformities and performing client satisfaction survey are the key for the continual improvement.
Continuous monitoring of arthritis in animal models using optical imaging modalities
NASA Astrophysics Data System (ADS)
Son, Taeyoon; Yoon, Hyung-Ju; Lee, Saseong; Jang, Won Seuk; Jung, Byungjo; Kim, Wan-Uk
2014-10-01
Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities-cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging-for continuous evaluation and monitoring of arthritis in animal models. C57BL/6 mice, used for the evaluation of arthritis, were divided into three groups: arthritic mice group (AMG), positive control mice group (PCMG), and negative control mice group (NCMG). Complete Freund's adjuvant, mineral oil, and saline were injected into the footpad for AMG, PCMG, and NCMG, respectively. LSC and CPC images were acquired from 0 through 144 h after injection for all groups. EI images were calculated from CPC images. Variations in feet area, EI, and speckle index for each mice group over time were calculated for quantitative evaluation of arthritis. Histological examinations were performed, and the results were found to be consistent with those from optical imaging analysis. Thus, optical imaging modalities may be successfully applied for continuous evaluation and monitoring of arthritis in animal models.
Cybersecurity Intrusion Detection and Monitoring for Field Area Network: Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pietrowicz, Stanley
This report summarizes the key technical accomplishments, industry impact and performance of the I2-CEDS grant entitled “Cybersecurity Intrusion Detection and Monitoring for Field Area Network”. Led by Applied Communication Sciences (ACS/Vencore Labs) in conjunction with its utility partner Sacramento Municipal Utility District (SMUD), the project accelerated research on a first-of-its-kind cybersecurity monitoring solution for Advanced Meter Infrastructure and Distribution Automation field networks. It advanced the technology to a validated, full-scale solution that detects anomalies, intrusion events and improves utility situational awareness and visibility. The solution was successfully transitioned and commercialized for production use as SecureSmart™ Continuous Monitoring. Discoveries made withmore » SecureSmart™ Continuous Monitoring led to tangible and demonstrable improvements in the security posture of the US national electric infrastructure.« less
NASA Astrophysics Data System (ADS)
Bednarski, Ł.; Sieńko, R.; Howiacki, T.
2017-10-01
This article presents the possibility of using structural health monitoring system data for the analysis of structure’s operation during its life cycle. Within the specific case study it was proved, that continuous, automatic and long term monitoring of selected physical quantities such as strains and temperatures, can significantly improve the assessment of technical condition by identifying hazardous phenomena. In this work the analysis of structural behaviour of post-tensioned girders within the roofing of sport halls in Cracow, Poland, was performed based on measurement results and verified by numerical model carried out in SOFiSTiK software. Thanks to the possibility of performing calculations in real time and informing the manager of the object about abnormalities it is possible to manage the structure in effective way by, inter alia, planning the renovations or supporting decisions about snow removal.
Casner, Stephen M; Schooler, Jonathan W
2015-09-01
In laboratory studies of vigilance, participants watch for unusual events in a "sit and stare" fashion as their performance typically declines over time. But watch keepers in practical settings seldom approach monitoring in such simplistic ways and controlled environments. We observed airline pilots performing routine monitoring duties in the cockpit. Unlike laboratory studies, pilots' monitoring did not deteriorate amidst prolonged vigils. Monitoring was frequently interrupted by other pop-up tasks and misses followed. However, when free from these distractions, pilots reported copious mind wandering. Pilots often confined their mind wandering to times in which their monitoring performance would not conspicuously suffer. But when no convenient times were available, pilots mind wandered anyway and misses ensued. Real-world monitors may be caught between a continuous vigilance approach that is doomed to fail, a dynamic environment that cannot be fully controlled, and what may be an irresistible urge to let one's thoughts drift. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Cordes, A.; Pollig, D.; Leonhardt, S.
2010-04-01
For monitoring the health status of individuals, proper monitoring of ventilation is desirable. Therefore, a continuous measurement technique is an advantage for many patients since it allows personal home care scenarios. As an example, monitoring of elderly people at home could enable them to live in their familiar environment on their own with the safety of a continuous monitoring. Therefore, a measurement technique without the restriction of mobility is required. Since it is possible to monitor ventilation with magnetic impedance measurements without conductive contact, this technique is well suited for the mentioned scenario. Integrated in a chair, a person's health state could be monitored in many situations, e.g. during meals, while watching TV or reading a book. In this paper, we compare different positions of coil arrays for a magnetic impedance measurement system integrated in a chair in order to monitor ventilation continuously. For limiting the costs and technical complexity of the magnetic impedance measurement system, we have a focus on coil configurations with one RF channel. To limit the needed space and thickness of the array in the backrest, planar gradiometer coil setups are investigated. All measurements will be performed with a new developed portable magnetic impedance measurement system and a standard office chair.
The U.S. EPA’s Technology Testing and Evaluation Program has been charged by EPA to evaluate the performance of commercially available water security-related technologies. Multi-parameter water monitors for distributions systems have been evaluated as such a water security techn...
Evaluation of the semi-continuous Monitor for Aerosols and Gases in Ambient Air (MARGA, Metrohm Applikon B.V.) was conducted with an emphasis on examination of accuracy and precision associated with processing of chromatograms. Using laboratory standards and atmospheric measureme...
Measuring, managing and maximizing performance of mineral processing plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bascur, O.A.; Kennedy, J.P.
1995-12-31
The implementation of continuous quality improvement is the confluence of Total Quality Management, People Empowerment, Performance Indicators and Information Engineering. The supporting information technologies allow a mineral processor to narrow the gap between management business objectives and the process control level. One of the most important contributors is the user friendliness and flexibility of the personal computer in a client/server environment. This synergistic combination when used for real time performance monitoring translates into production cost savings, improved communications and enhanced decision support. Other savings come from reduced time to collect data and perform tedious calculations, act quickly with fresh newmore » data, generate and validate data to be used by others. This paper presents an integrated view of plant management. The selection of the proper tools for continuous quality improvement are described. The process of selecting critical performance monitoring indices for improved plant performance are discussed. The importance of a well balanced technological improvement, personnel empowerment, total quality management and organizational assets are stressed.« less
Hemodynamic monitoring in the critically ill.
Voga, G
1995-06-01
Monitoring of vital functions is one of the most important and essential tools in the management of critically ill patients in the ICU. Today it is possible to detect and analyze a great variety of physiological signals by various noninvasive and invasive techniques. An intensivist should be able to select and perform the most appropriate monitoring method for the individual patient considering risk-benefit ratio of the particular monitoring technique and the need for immediate therapy, specific diagnosis, continuous monitoring and evaluation of morphology should be included. Despite rapid development of noninvasive monitoring techniques, invasive hemodynamic monitoring in still one of the most basic ICU procedures. It enables monitoring of pressures, flow and saturation, pressures in the systemic and pulmonary circulation, estimation of cardiac performance and judgment of the adequacy of the cardiocirculatory system. Carefully and correctly obtained information are basis for proper hemodynamic assessment which usually effects the therapeutic decisions.
Kerr, David; Olateju, Tolu
2010-06-01
Pascal's Wager is a suggestion posed by the French Philosopher, Blaise Pascal, that even though the existence of God cannot be determined through reason, a person should wager that God exists because he or she has everything to gain and nothing to lose. In the area of consideration here, the optimum experimental trial of the combined use of continuous subcutaneous insulin infusion and real-time continuous glucose monitoring in free-living individuals with type 1 diabetes providing rock-solid evidence of clinical benefit has not been performed. Nevertheless, there is considerable enthusiasm for combining the technologies among healthcare professionals, patients, and manufacturers based on the belief that this approach to diabetes care must be beneficial beyond the available evidence (i.e., reason).
An investment benefiting America's highways : the long term pavement performance program
DOT National Transportation Integrated Search
2000-01-01
The Federal Highway Administration (FHWA) and the States, beginning in 1978, jointly developed and implemented a continuous data collection system called the Highway Performance Monitoring System (HPMS). Currently, the HPMS contains over 110,000 high...
Code of Federal Regulations, 2013 CFR
2013-07-01
... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...
Code of Federal Regulations, 2012 CFR
2012-07-01
... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...
Code of Federal Regulations, 2010 CFR
2010-07-01
... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Performance Tests... of NOX emission controls in accordance with § 60.4340, the appropriate parameters must be...
Evaluation of performance of asphalt pavements constructed using intelligent compaction techniques.
DOT National Transportation Integrated Search
2014-10-01
The long-term performance of asphalt pavements depends on the quality of the subgrade and : asphalt layers. Intelligent compaction methods continuously monitor the modulus/stiffness of : subgrade and asphalt layers during compaction process and have ...
In September 1997, the U.S. Department of Energy (DOE) and U.S. Environmental Protection Agency (EPA) co-sponsored a demonstration of several multimetal continuous emission monitos (CEMs). The demonstration, performed at the EPA National Risk Management Research Laboratory, Air P...
Harigae, M; Hirose, Y; Gamo, M; Hirose, M; Fujiwara, C; Matsuo, K
1999-03-01
We applied a continuous intra-arterial blood gas monitoring system (Paratrend 7) to a patient with pulmonary alveolar proteinosis during pulmonary lavage. Lavage was performed under general anesthesia with one lung ventilation. We inserted the sensor of Patatrend 7 through a 20 G catheter into the radial artery, and monitored pH, PaCO2 and PaO2 continuously throughout the procedure. SpO2 and EtCO2 were also monitored. Saline 1000-1500 ml was instilled and drained repeatedly by volume limited methods. PaO2 values by Paratrend 7 increased during instillation and decreased during drainage of the irrigating fluid. In contrast, PaCO2 value by Paratrend 7 decreased slightly during instillation and increased during drainage. The change of SpO2 was almost the same as that by Paratrend 7, but the response time of pulse oxymetry was a little quicker than Paratrend 7. During the lavage procedure, respiratory and circulatory condition changed very rapidly, and it is necessary to monitor blood gas change intensively. Paratrend 7 is useful as a perioperative monitoring system, but pulse oxymetry might be sufficient during pulmonary lavage considering its cost.
Stepping-Motion Motor-Control Subsystem For Testing Bearings
NASA Technical Reports Server (NTRS)
Powers, Charles E.
1992-01-01
Control subsystem closed-loop angular-position-control system causing motor and bearing under test to undergo any of variety of continuous or stepping motions. Also used to test bearing-and-motor assemblies, motors, angular-position sensors including rotating shafts, and like. Monitoring subsystem gathers data used to evaluate performance of bearing or other article under test. Monitoring subsystem described in article, "Monitoring Subsystem For Testing Bearings" (GSC-13432).
The Use of Continuous Electrocardiographic Holter Monitoring in Pediatric Cardiology
Begic, Zijo; Begic, Edin; Mesihovic-Dinarevic, Senka; Masic, Izet; Pesto, Senad; Halimic, Mirza; Kadic, Almira; Dobraca, Amra
2016-01-01
Objective: To show the place and role of continuous electrocardiographic twenty-four-hour ECG monitoring in daily clinical practice of pediatric cardiologists. Methods: According to protocol, 2753 patients underwent dynamic continuous ECG Holter monitoring (data collected from the “Register of ECG Holter monitoring” of Pediatric Clinic, UCC Sarajevo in period April 2003- April 2015). Results: There were 50,5% boys and 49,5% girls, aged from birth to 19 years (1,63% - neonates and infants, 2,6% - toddlers, 9,95% - preschool children, 35,5% - gradeschoolers and 50,3% children in puberty and adolescence). In 68,1% of patients Holter was performed for the first time. Indications for conducting Holter were: arrhythmias in 42,2% cases, precordial pain in 23,5%, suspicion of pre-excitation and/or pre-excitation in 10%, crisis of consciousness in 8%, uncorrected congenital/acquired heart defects in 4,2%, operated heart defects in 3,7%, hypertension in 3,1% cases, control of the pacemaker in 1,63% and other causes in 3,5% cases. Discharge diagnosis after ECG Holter monitoring were: insignificant arrhythmias in 47,1% cases, wandering pacemaker in 21,3%, pre-excitation in 16,2%, benign ventricular premature beats in 6,3%, atrioventricular block in 3%, sinus pause in 2.2% cases and other arrhythmias in 3,5%. In mentioned period 57 cases of Wolf Parkinson White syndrome were registered, in 4,5% of patients antiarrhythmic therapy was administered. Radiofrequent ablation was performed in 23 cases. Conclusion: The development of pediatric cardiac surgery has initiated development of pediatric arrhythmology as imperative segment of pediatric cardiology. Continuous ECG Holter monitoring has become irreplaceable method in everyday diagnostics and therapy of arrhythmias in children. PMID:27708487
López, María Mercedes; Guasch, Emilia; Schiraldi, Renato; Maggi, Genaro; Alonso, Eduardo; Gilsanz, Fernando
2016-01-01
Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Specification Test Procedures for Monitoring Systems for Effluent Stream Gas Volumetric Flow Rate E Appendix E... Stream Gas Volumetric Flow Rate 1. Principle and applicability. 1.1Principle. Effluent stream gas... method is applicable to subparts which require continuous gas volumetric flow rate measurement...
Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa
2015-02-09
False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.
Manufacturing of Wearable Sensors for Human Health and Performance Monitoring
NASA Astrophysics Data System (ADS)
Alizadeh, Azar
2015-03-01
Continuous monitoring of physiological and biological parameters is expected to improve performance and medical outcomes by assessing overall health status and alerting for life-saving interventions. Continuous monitoring of these parameters requires wearable devices with an appropriate form factor (lightweight, comfortable, low energy consuming and even single-use) to avoid disrupting daily activities thus ensuring operation relevance and user acceptance. Many previous efforts to implement remote and wearable sensors have suffered from high cost and poor performance, as well as low clinical and end-use acceptance. New manufacturing and system level design approaches are needed to make the performance and clinical benefits of these sensors possible while satisfying challenging economic, regulatory, clinical, and user-acceptance criteria. In this talk we will review several recent design and manufacturing efforts aimed at designing and building prototype wearable sensors. We will discuss unique opportunities and challenges provided by additive manufacturing, including 3D printing, to drive innovation through new designs, faster prototyping and manufacturing, distributed networks, and new ecosystems. We will also show alternative hybrid self-assembly based integration techniques for low cost large scale manufacturing of single use wearable devices. Coauthors: Prabhjot Singh and Jeffrey Ashe.
Kim, Jung Hyup; Rothrock, Ling; Laberge, Jason
2014-05-01
This paper provides a case study of Signal Detection Theory (SDT) as applied to a continuous monitoring dual-task environment. Specifically, SDT was used to evaluate the independent contributions of sensitivity and bias to different qualitative gauges used in process control. To assess detection performance in monitoring the gauges, we developed a Time Window-based Human-In-The-Loop (TWHITL) simulation bed. Through this test bed, we were able to generate a display similar to those monitored by console operators in oil and gas refinery plants. By using SDT and TWHITL, we evaluated the sensitivity, operator bias, and response time of flow, level, pressure, and temperature gauge shapes developed by Abnormal Situation Management(®) (ASM(®)) Consortium (www.asmconsortium.org). Our findings suggest that display density influences the effectiveness of participants in detecting abnormal shapes. Furthermore, results suggest that some shapes elicit better detection performance than others. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-09-24
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.
40 CFR 63.7947 - What are my monitoring alternatives?
Code of Federal Regulations, 2010 CFR
2010-07-01
...). (3) You must conduct a performance evaluation of the CEMS according to the requirements in § 63.8 and Performance Specification 8 (for a total organic emissions CEMS) or Performance Specification 9 (for a HAP...? 63.7947 Section 63.7947 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...
Effect of quality metric monitoring and colonoscopy performance.
Razzak, Anthony; Smith, Dineen; Zahid, Maliha; Papachristou, Georgios; Khalid, Asif
2016-10-01
Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements for compliance with my operating limits? 60.5225 Section 60.5225 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Existing Sewage Sludge Incineration Units Model Rule...
40 CFR 63.1456 - What records must I keep and how long must I keep my records?
Code of Federal Regulations, 2011 CFR
2011-07-01
... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants for Primary Copper Smelting... affiliation for each indoor process monitor participating in the performance test; (v) Copies of all visible...
40 CFR 63.1456 - What records must I keep and how long must I keep my records?
Code of Federal Regulations, 2010 CFR
2010-07-01
... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants for Primary Copper Smelting... affiliation for each indoor process monitor participating in the performance test; (v) Copies of all visible...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
40 CFR 60.256 - Continuous monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
....256 Section 60.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... rates of 25 Mg (28 tons) per year or more, a bag leak detection system according to the requirements in... performance test on an operating day average basis. (c) Each bag leak detection system used to comply with...
Commercialization Issues For Catheter-Based Electrochemical Sensors
NASA Astrophysics Data System (ADS)
Nikolchev, Julian; Gaisford, Scott
1989-08-01
The need for continuous monitoring of key clinical parameters in hospitals is well recognized. Figure 1 shows typical time constants for blood gases, ions and enzymes in response to acute ventilatory changes and interventions. Although it can be seen that relatively low rates of data collection are necessary for many medical measurements, it is also clear that intermittent measurement of P02, PCO2 and pH are not sufficient to provide safe and effective management of the patient. Very frequent or continuous monitoring is often essential. This figure also shows why the emphasis of a large number of research efforts in this country and in Europe and Japan have as their goal the development of continuous blood gas sensors, i.e., sensors that continuously monitor blood pH, partial pressure of oxygen and partial pressure of carbon dioxide. These are three (3) of the most frequent parameters measured in hospitals and the ones having the shortest time constant. Considering that in the United States alone close to 25 million blood gas samples per year are taken from patients, the potential market for continuous monitoring sensors is enormous. The emergence of microelectronics and microfabrication technologies over the past 30 years are now pointing to a possible resolution of the well recognized need for real time monitoring of critically ill patients through catheter-based sensors. Although physicians will always prefer non-invasive monitoring techniques, there are a number of parameters that presently can only be monitored by invasive method. The emerging ability to miniaturize chemical sensors using silicon microfabrication or fiber-optic techniques offer an excellent opportunity to solve this need. In fact, the development of in vivo biomedical sensors with satisfactory performance characteristics has long been considered the ultimate application of these emerging technologies.
Continuous event monitoring via a Bayesian predictive approach.
Di, Jianing; Wang, Daniel; Brashear, H Robert; Dragalin, Vladimir; Krams, Michael
2016-01-01
In clinical trials, continuous monitoring of event incidence rate plays a critical role in making timely decisions affecting trial outcome. For example, continuous monitoring of adverse events protects the safety of trial participants, while continuous monitoring of efficacy events helps identify early signals of efficacy or futility. Because the endpoint of interest is often the event incidence associated with a given length of treatment duration (e.g., incidence proportion of an adverse event with 2 years of dosing), assessing the event proportion before reaching the intended treatment duration becomes challenging, especially when the event onset profile evolves over time with accumulated exposure. In particular, in the earlier part of the study, ignoring censored subjects may result in significant bias in estimating the cumulative event incidence rate. Such a problem is addressed using a predictive approach in the Bayesian framework. In the proposed approach, experts' prior knowledge about both the frequency and timing of the event occurrence is combined with observed data. More specifically, during any interim look, each event-free subject will be counted with a probability that is derived using prior knowledge. The proposed approach is particularly useful in early stage studies for signal detection based on limited information. But it can also be used as a tool for safety monitoring (e.g., data monitoring committee) during later stage trials. Application of the approach is illustrated using a case study where the incidence rate of an adverse event is continuously monitored during an Alzheimer's disease clinical trial. The performance of the proposed approach is also assessed and compared with other Bayesian and frequentist methods via simulation. Copyright © 2015 John Wiley & Sons, Ltd.
Software for marine ecological environment comprehensive monitoring system based on MCGS
NASA Astrophysics Data System (ADS)
Wang, X. H.; Ma, R.; Cao, X.; Cao, L.; Chu, D. Z.; Zhang, L.; Zhang, T. P.
2017-08-01
The automatic integrated monitoring software for marine ecological environment based on MCGS configuration software is designed and developed to realize real-time automatic monitoring of many marine ecological parameters. The DTU data transmission terminal performs network communication and transmits the data to the user data center in a timely manner. The software adopts the modular design and has the advantages of stable and flexible data structure, strong portability and scalability, clear interface, simple user operation and convenient maintenance. Continuous site comparison test of 6 months showed that, the relative error of the parameters monitored by the system such as temperature, salinity, turbidity, pH, dissolved oxygen was controlled within 5% with the standard method and the relative error of the nutrient parameters was within 15%. Meanwhile, the system had few maintenance times, low failure rate, stable and efficient continuous monitoring capabilities. The field application shows that the software is stable and the data communication is reliable, and it has a good application prospect in the field of marine ecological environment comprehensive monitoring.
FIELD STUDIES OF IMPREGNATED CONCRETE PIPE
The follow-on study (initiated in June 1980) continued to monitor performance of 1,400 ft of impregnated concrete pipe installed in several Texas cities. The performance of concrete pipe has been compared with that of sulfur-impregnated concrete pipe; hydrofluoric acid (HF)-treat...
Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources
NASA Technical Reports Server (NTRS)
Ding, Leibo; Kowalewski, Matthew G.; Cooper, John W.; Smith, GIlbert R.; Barnes, Robert A.; Waluschka, Eugene; Butler, James J.
2011-01-01
The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.
Zanderigo, Francesca; Sparacino, Giovanni; Kovatchev, Boris; Cobelli, Claudio
2007-09-01
The aim of this article was to use continuous glucose error-grid analysis (CG-EGA) to assess the accuracy of two time-series modeling methodologies recently developed to predict glucose levels ahead of time using continuous glucose monitoring (CGM) data. We considered subcutaneous time series of glucose concentration monitored every 3 minutes for 48 hours by the minimally invasive CGM sensor Glucoday® (Menarini Diagnostics, Florence, Italy) in 28 type 1 diabetic volunteers. Two prediction algorithms, based on first-order polynomial and autoregressive (AR) models, respectively, were considered with prediction horizons of 30 and 45 minutes and forgetting factors (ff) of 0.2, 0.5, and 0.8. CG-EGA was used on the predicted profiles to assess their point and dynamic accuracies using original CGM profiles as reference. Continuous glucose error-grid analysis showed that the accuracy of both prediction algorithms is overall very good and that their performance is similar from a clinical point of view. However, the AR model seems preferable for hypoglycemia prevention. CG-EGA also suggests that, irrespective of the time-series model, the use of ff = 0.8 yields the highest accurate readings in all glucose ranges. For the first time, CG-EGA is proposed as a tool to assess clinically relevant performance of a prediction method separately at hypoglycemia, euglycemia, and hyperglycemia. In particular, we have shown that CG-EGA can be helpful in comparing different prediction algorithms, as well as in optimizing their parameters.
Chojin, Yasuo; Ishimoto, Hiroshi; Noguchi, Shingo; Kawanami, Toshinori; Kato, Tatsuji; Mukae, Hiroshi; Yatera, Kazuhiro
To perform a bronchoscopy safely, it is very important to make a risk assessment before and after the procedure. There have been no reports of hypoxemia during sleep on the day after a bronchoscopic examination; therefore, we evaluated the oxygen saturation status during sleep on the days before and after bronchoscopy. Thirty patients that underwent bronchoscopy were studied. Continuous pulse oximetry monitoring was performed on the day before bronchoscopy and the day when the bronchoscopy was performed. The average oxygen saturation levels and the oxygen desaturation index (ODI) were evaluated. There was a significant increase (P < 0.05) in the ODI-3% during sleep on the day of the bronchoscopy compared to the day before the bronchoscopy. Clinicians should pay careful attention to hypoxia not only during bronchoscopy, but also during sleep on the night following the procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 62.15220 Section 62.15220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... the operation of my continuous emission monitoring systems and continuous opacity monitoring system...
Optimum aerobic volume control based on continuous in-line oxygen uptake monitoring.
Svardal, K; Lindtner, S; Winkler, S
2003-01-01
Dynamic adaptation of the aerated volume to changing load conditions is essential to maximise the nitrogen removal performance and to minimise energy consumption. A control strategy is presented which provides optimum aerobic volume control (OAV-control concept) based on continuous in-line oxygen uptake monitoring. For ammonium concentrations below 1 mg/l the oxygen uptake rate shows a strong and almost linear dependency on the ammonium concentration. Therefore, the oxygen uptake rate is an ideal indicator for the nitrification performance in activated sludge systems. The OAV-control concept provides dynamic variation of the minimum aerobic volume required for complete nitrification and therefore maximises the denitrification performance. In-line oxygen uptake monitoring is carried out by controlling the oxygen concentration in a continuous aerated zone of the aeration tank and measuring the total air flow to the aeration tank. The total air flow to the aeration tank is directly proportional to the current oxygen uptake rate and can therefore be used as an indicator for the required aerobic volume. The instrumentation requirements for installation of the OAV-control are relatively low, oxygen sensors in the aeration tank and an on-line air flow measurement are needed. This enables individual control of aeration tanks operated in parallel at low investment costs. The OAV-control concept is installed at the WWTP Linz-Asten (1 Mio PE) and shows very good results. Full scale results are presented.
1983-05-01
AVAILABILITY OF REPORT Approved for public release; 2b. DECLASSIFICATION I DOWNGRADING SCHEDULE Distribution Unlimited 4. PERFORMING ORGANIZATION REPORT NUMBER(S...S. MONITORING ORGANIZATION REPORT NUMBER(S) 1-88 6a. NAME OF PERFORMING ORGANIZATION 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION U.S. Army...identify by block number) FIELD GROUP SUB-GROUP Health Care; Appointment Absenteeism - ... 19, ABSTRACT (Continue on reverse if necessary and identify
ERIC Educational Resources Information Center
Parenti, Melissa A.
2016-01-01
The benefits of motivation, mental imagery, self-monitoring and guided retellings on reading comprehension have long been lauded as effective methods for improving reading achievement. At a time when technology continues to flourish, yet secondary reading performance remains at a level far below proficiency, identifying strategies that assist in…
40 CFR Table 3 to Subpart Oooo of... - Applicability of General Provisions to Subpart OOOO
Code of Federal Regulations, 2013 CFR
2013-07-01
... of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution Pt. 60, Subpt... Yes. § 60.4 Address Yes. § 60.5 Determination of construction or modification Yes. § 60.6 Review of... in subpart OOOO. § 60.12 Circumvention Yes. § 60.13 Monitoring requirements Yes Continuous monitors...
40 CFR Table 3 to Subpart Oooo of... - Applicability of General Provisions to Subpart OOOO
Code of Federal Regulations, 2014 CFR
2014-07-01
... of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution Pt. 60, Subpt... Yes. § 60.4 Address Yes. § 60.5 Determination of construction or modification Yes. § 60.6 Review of... in subpart OOOO. § 60.12 Circumvention Yes. § 60.13 Monitoring requirements Yes Continuous monitors...
40 CFR 63.1210 - What are the notification requirements?
Code of Federal Regulations, 2013 CFR
2013-07-01
... change in information already provided under § 63.9. 63.1206(b)(5)(i) Notification of changes in design...), 63.9(e) 63.9(g)(1) and (3) Notification of performance test and continuous monitoring system evaluation, including the performance test plan and CMS performance evaluation plan.1 63.1210(b) Notification...
40 CFR 63.1210 - What are the notification requirements?
Code of Federal Regulations, 2014 CFR
2014-07-01
... change in information already provided under § 63.9. 63.1206(b)(5)(i) Notification of changes in design...), 63.9(e) 63.9(g)(1) and (3) Notification of performance test and continuous monitoring system evaluation, including the performance test plan and CMS performance evaluation plan.1 63.1210(b) Notification...
40 CFR 63.9642 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Records of performance tests and performance evaluations as required in § 63.10(b)(2)(viii). (b) For each... described in § 63.10(b)(2)(vi) through (xi). (2) Monitoring data for COMS during a performance evaluation as... Section 63.9642 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
Flight Test of Propulsion Monitoring and Diagnostic System
NASA Technical Reports Server (NTRS)
Gabel, Steve; Elgersma, Mike
2002-01-01
The objective of this program was to perform flight tests of the propulsion monitoring and diagnostic system (PMDS) technology concept developed by Honeywell under the NASA Advanced General Aviation Transport Experiment (AGATE) program. The PMDS concept is intended to independently monitor the performance of the engine, providing continuous status to the pilot along with warnings if necessary as well as making the data available to ground maintenance personnel via a special interface. These flight tests were intended to demonstrate the ability of the PMDS concept to detect a class of selected sensor hardware failures, and the ability to successfully model the engine for the purpose of engine diagnosis.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
Code of Federal Regulations, 2010 CFR
2010-07-01
... meet for the operation of my continuous emission monitoring systems and continuous opacity monitoring system? 60.1765 Section 60.1765 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... continuous emission monitoring systems and continuous opacity monitoring system? Use the required span values...
Validating Future Force Performance Measures (Army Class): End of Training Longitudinal Validation
2009-09-01
Organization 66 Canal Center Plaza, Suite 700 Alexandria, Virginia 22314 8 . PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING...4 Table B. 8 . Intercorrelations among RBI Scale Scores...12. Intercorrelations among WPA Dimension and Facet Scores ...................................... 8 x xi CONTENTS (continued) Page
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peduto, E.F. Jr.; Porter, T.J.; Midgley, D.P.
1984-03-01
The report gives results of a continuous monitoring demonstration at the Columbus and Southern Ohio Electric Company's Conesville Generating Station. The purpose of the demonstration was to determine the feasibility of the requirements for monitoring and control of SO2 emissions as specified in 40 CFR, Part 60, Subpart Da, which promulgates new source performance standards (NSPS) for new utility steam generators. A secondary objective was to adhere to the draft quality assurance requirements scheduled for promulgation as Appendix F. The report describes program activities and results of the field portion, during which data were collected for about 12 months ofmore » a 16-month period.« less
NASA Astrophysics Data System (ADS)
Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.
2018-02-01
We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.
Kotamäki, Niina; Thessler, Sirpa; Koskiaho, Jari; Hannukkala, Asko O.; Huitu, Hanna; Huttula, Timo; Havento, Jukka; Järvenpää, Markku
2009-01-01
Sensor networks are increasingly being implemented for environmental monitoring and agriculture to provide spatially accurate and continuous environmental information and (near) real-time applications. These networks provide a large amount of data which poses challenges for ensuring data quality and extracting relevant information. In the present paper we describe a river basin scale wireless sensor network for agriculture and water monitoring. The network, called SoilWeather, is unique and the first of this type in Finland. The performance of the network is assessed from the user and maintainer perspectives, concentrating on data quality, network maintenance and applications. The results showed that the SoilWeather network has been functioning in a relatively reliable way, but also that the maintenance and data quality assurance by automatic algorithms and calibration samples requires a lot of effort, especially in continuous water monitoring over large areas. We see great benefits on sensor networks enabling continuous, real-time monitoring, while data quality control and maintenance efforts highlight the need for tight collaboration between sensor and sensor network owners to decrease costs and increase the quality of the sensor data in large scale applications. PMID:22574050
Electronic Reporting of Air Emissions
EPA regulations require affected sources to perform emissions source tests, conduct continuous emissions monitoring, and submit compliance and emissions reports. This site provides technical resources and access for providing such submissions.
Novel textile systems for the continuous monitoring of vital signals: design and characterization.
Trindade, Isabel G; Martins, Frederico; Dias, Rúben; Oliveira, Cristina; Machado da Silva, José
2015-08-01
In this article we present a smart textile system for the continuous monitoring of cardiorespiratory signals, produced and integrated with an industrial embroidery unit. The design of a T-shirt system, having embedded textile sensors and interconnects and custom designed circuit for data collection and Bluetooth transmission is presented. The performance of skin-contact textile electrodes, having distinctive electrical characteristics and surface morphologies, was characterized by measurements of signal to noise ratio, under dry and moisture conditions. The influence of the electrodes size and the wear resistance were addressed. Results of an electrocardiogram acquisition with a subject wearing the T-shirt and display on a smartphone are also shown. The presented smart textile systems exhibit good performance and versatility for custom demand production.
Hehmke, Bernd; Berg, Sabine; Salzsieder, Eckhard
2017-05-01
Continuous standardized verification of the accuracy of blood glucose meter systems for self-monitoring after their introduction into the market is an important clinically tool to assure reliable performance of subsequently released lots of strips. Moreover, such published verification studies permit comparison of different blood glucose monitoring systems and, thus, are increasingly involved in the process of evidence-based purchase decision making.
Evaluation of the VIIRS Ocean Color Monitoring Performance in Coastal Regions
2013-09-17
collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1...part of the VIIRS sensor calibration and validation efforts, our group has been continuously monitoring the validity of the VIlRS’s OC and atmospheric...the necessity for monitoring and assessing the validity and consistency of VIIRS’ ocean color pioducts. especially for coaslal waters. 15. SUBJECT
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring requirements for a continuous emissions monitoring system? 63.7747 Section 63.7747 Protection of... apply for alternative monitoring requirements for a continuous emissions monitoring system? (a) You may... prevention technique, a description of the continuous monitoring system or method including appropriate...
Torres Lacruz, M; Barrio Castellanos, R; García Cuartero, B; Gómez Gila, A; González Casado, I; Hermoso López, F; Luzuriaga Tomás, C; Oyarzabal Irigoyen, M; Rica Etxebarria, I; Rodríguez Rigual, M
2011-08-01
Glucose monitoring methods have made great advances in the last decade with the appearance of the continuous glucose monitoring systems (CGMS) that measure the glucose levels in the interstitial liquid, providing information about glucose patterns and trends, but do not replace the self-monitoring of capillary glucose. Improvement in diabetes control using the CGMS depends on the motivation and training received by the patient and family and on the continuity in its use. Due to the development and widespread use of these systems in clinical practice, the diabetes group of the Sociedad Española de Endocrinología Pediátrica has drafted a document of consensus for their indication and use in children and adolescents. Only a limited number of trials have been performed in children and adolescent populations. More data are needed on the use of this technology in order to define the impact on metabolic control. Copyright © 2010 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Carstea, E.; Baker, A.; Johnson, R.; Reynolds, D. M.
2009-12-01
In-line fluorescence EEM monitoring has been performed over an eleven-day period for Bournbrook River, Birmingham, UK. River water was diverted to a portable laboratory via a continuous flow pump and filter system. Fluorescence excitation-emission matrices data was recorded every 3 minutes using a flow cell (1cm pathlength) coupled to a fiber optic probe. This real-time fluorescence EEM data (Excitation, 225-400 nm at 5 nm steps, emission, 280-500 nm at 2 nm steps) was collected 'in-line'and directly compared with the spectrophotometric properties and physical and chemical parameters of river water samples collected off-line at known time intervals. Over the monitoring period, minor pollution pulses from cross connections were detected and identified hourly along with a random diesel pollution event. This work addresses the practicalities of measuring and detecting fluorescence EEM in the field and discusses the potential of this technological approach for further understanding important hydrological and biogeochemical processes. Problems associated with fouling and system failure are also reported. Example of the data generated from the continuous fluorescence EEM monitoring.
40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1250 What is my schedule for evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13...
40 CFR 60.113 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.115a - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.115a - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.113 - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.115a - Monitoring of operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.113 - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.113 - Monitoring of operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.115a - Monitoring of operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.115a - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
40 CFR 60.113 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid during the respective storage period. (b) Available data on the typical Reid vapor pressure and the maximum... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels...
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays.
Mohan, A M Vinu; Windmiller, Joshua Ray; Mishra, Rupesh K; Wang, Joseph
2017-05-15
The present work describes an attractive skin-worn microneedle sensing device for the minimally invasive electrochemical monitoring of subcutaneous alcohol. The device consists of an assembly of pyramidal microneedle structures integrated with Pt and Ag wires, each with a microcavity opening. The microneedle aperture was modified by electropolymerizing o-phenylene diamine onto the Pt wire microtransducer, followed by the immobilization of alcohol oxidase (AOx) in an intermediate chitosan layer, along with an outer Nafion layer. The resulting microneedle-based enzyme electrode displays an interference-free ethanol detection in artificial interstitial fluid without compromising its sensitivity, stability and response time. The skin penetration ability and the efficaciousness of the biosensor performance towards subcutaneous alcohol monitoring was substantiated by the ex vivo mice skin model analysis. Our results reveal that the new microneedle sensor holds considerable promise for continuous non-invasive alcohol monitoring in real-life situations. Copyright © 2017 Elsevier B.V. All rights reserved.
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Vinu Mohan, A. M.; Windmiller, Joshua Ray; Mishra, Rupesh K.; Wang, Joseph
2017-01-01
The present work describes an attractive skin-worn microneedle sensing device for the minimally invasive electrochemical monitoring of subcutaneous alcohol. The device consists of an assembly of pyramidal microneedle structures integrated with Pt and Ag wires, each with a microcavity opening. The microneedle aperture was modified by electropolymerizing o-phenylene diamine onto the Pt wire microtransducer, followed by the immobilization of alcohol oxidase (AOx) in an intermediate chitosan layer, along with an outer Nafion layer. The resulting microneedle-based enzyme electrode displays an interference-free ethanol detection in artificial interstitial fluid without compromising its sensitivity, stability and response time. The skin penetration ability and the efficaciousness of the biosensor performance towards subcutaneous alcohol monitoring was substantiated by the ex vivo mice skin model analysis. Our results reveal that the new microneedle sensor holds considerable promise for continuous non-invasive alcohol monitoring in real-life situations. PMID:28088750
Development of an electronic nose for environmental odour monitoring.
Dentoni, Licinia; Capelli, Laura; Sironi, Selena; Del Rosso, Renato; Zanetti, Sonia; Della Torre, Matteo
2012-10-25
Exhaustive odour impact assessment should involve the evaluation of the impact of odours directly on citizens. For this purpose it might be useful to have an instrument capable of continuously monitoring ambient air quality, detecting the presence of odours and also recognizing their provenance. This paper discusses the laboratory and field tests conducted in order to evaluate the performance of a new electronic nose, specifically developed for monitoring environmental odours. The laboratory tests proved the instrument was able to discriminate between the different pure substances being tested, and to estimate the odour concentrations giving correlation indexes (R2) of 0.99 and errors below 15%. Finally, the experimental monitoring tests conducted in the field, allowed us to verify the effectiveness of this electronic nose for the continuous detection of odours in ambient air, proving its stability to variable atmospheric conditions and its capability to detect odour peaks.
Passive sampling of gas-phase air toxics and criteria pollutants has become an attractive monitoring method in human exposure studies due to the relatively low sampling cost and ease of use. This study evaluates the performance of Model 3300 Ogawa(TM) Passive NO2 Samplers and 3...
Rotor Smoothing and Vibration Monitoring Results for the US Army VMEP
2009-06-01
individual component CI detection thresholds, and development of models for diagnostics, prognostics , and anomaly detection . Figure 16 VMEP Server...and prognostics are of current interest. Development of those systems requires large amounts of data (collection, monitoring , manipulation) to capture...development of automated systems and for continuous updating of algorithms to improve detection , classification, and prognostic performance. A test
Ambient air monitoring as part of the U.S. Environmental Protection Agency’s (U.S. EPA’s) Clean Air Status and Trends Network (CASTNet) currently uses filter packs to measure weekly integrated concentrations. The U.S. EPA is interested in supplementing CASTNet with semi-continuou...
Tura, A; Badanai, M; Longo, D; Quareni, L
2004-01-01
A portable monitoring device was developed to assist in the management of children with a learning disability. The device was designed for continuous home monitoring of blood oxygen saturation, heart and respiration rates, and patient activity. It could be worn on a belt, while the patient continued normal activities. Data were stored on a multimedia card and automatically transmitted to a PC at prescribed intervals via a Bluetooth wireless link. From the PC the data were transmitted to a Web server, where the information was made available to the staff involved in the patient's care. Preliminary clinical studies were performed with nine patients (four with Down's syndrome, three with cerebral palsy and two with mental retardation). Patients and families considered the device easy to use and to wear. The monitoring device identified events of possible clinical interest. Although it was designed for monitoring children with a learning disability, it may also be useful with other groups, such as elderly people.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-01-01
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70–200 mg/dL), revealing high system performance for a wide glycemic state range (45–500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting. PMID:27669267
Code of Federal Regulations, 2011 CFR
2011-07-01
... performance test deadline for PM CEMS. Relative accuracy testing for other CEMS need not be repeated if that... system. (i) Installation of the continuous monitoring system sampling probe or other interface at a... equipment specifications for the sample interface, the pollutant concentration or parametric signal analyzer...
A continuous hanging iron wall was installed in June, 1996, at the U.S. Coast Guard (USCG) Support Center near Elizabeth City, NC, United States, to treat overlapping plumes of chromate and chlorinated solvent compounds. The wall was emplaced using a continuous trenching machine...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
40 CFR 63.5767 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... by an add-on control device (i.e., you are complying with organic HAP content limits, application...-average organic HAP content as determined in § 63.5749. (d) If your facility has an add-on control device... malfunction events; control device performance tests; and continuous monitoring system performance evaluations. ...
National Centers for Environmental Prediction
Modeling Center continuously monitors its NWP model performance against different performance measures, and AIRCFT GFS SSI and forecast fits to RAOBS for last 7 days spatial bias maps for different regions different regions GFS SSI and forecast fits to RAOBS for calendar months (time series, spatial and vertical
40 CFR 60.185 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Lead... reverberatory furnace, or sintering machine discharge end. The span of this system shall be set at 80 to 100... discharged into the atmosphere from any sintering machine, electric furnace or converter subject to § 60.183...
40 CFR 63.1260 - Reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... reconstruction. An owner or operator who is subject to § 63.5(b)(3) shall submit to the Administrator an...) Notification of CMS performance evaluation. An owner or operator who is required by the Administrator to conduct a performance evaluation for a continuous monitoring system shall notify the Administrator of the...
40 CFR 63.1260 - Reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... reconstruction. An owner or operator who is subject to § 63.5(b)(3) shall submit to the Administrator an...) Notification of CMS performance evaluation. An owner or operator who is required by the Administrator to conduct a performance evaluation for a continuous monitoring system shall notify the Administrator of the...
40 CFR 63.1260 - Reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator who is subject to § 63.5(b)(3) shall submit to the Administrator an application for approval of... evaluation. An owner or operator who is required by the Administrator to conduct a performance evaluation for a continuous monitoring system shall notify the Administrator of the date of the performance...
NASA Astrophysics Data System (ADS)
Chakrabarti, Bhabesh; Fine, Philip M.; Delfino, Ralph; Sioutas, Constantinos
The need for continuous personal monitoring for exposure to particulate matter has been demonstrated by recent health studies showing effects of PM exposure on time scales of less than a few hours. Filter-based methods cannot measure this short-term variation of PM levels, which can be quite significant considering human activity patterns. The goal of this study was to evaluate the active-flow personal DataRAM for PM 2.5 (MIE pDR-1200; Thermo Electron Corp., Franklin, MA) designed as a wearable monitor to continuously measure particle exposure. The instrument precision was found to be good (2.1%) and significantly higher than the passive pDR configuration tested previously. A comparison to other proven continuous monitors resulted in good agreement at low relative humidities. Results at higher humidity followed predictable trends and provided a correction scheme that improved the accuracy of pDR readings. The pDR response to particle size also corresponded to previously observed and theoretical errors. The active flow feature of the pDR allows collection of the sampled particles on a back-up filter. The 24-h mass measured on this filter was found to compare very well with a Federal Reference Method for PM 2.5 mass.
Assessment of hypoglycaemia awareness using continuous glucose monitoring.
Kubiak, T; Hermanns, N; Schreckling, H J; Kulzer, B; Haak, T
2004-05-01
To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring. Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic. Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable. The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.
Hybrid Modeling Improves Health and Performance Monitoring
NASA Technical Reports Server (NTRS)
2007-01-01
Scientific Monitoring Inc. was awarded a Phase I Small Business Innovation Research (SBIR) project by NASA's Dryden Flight Research Center to create a new, simplified health-monitoring approach for flight vehicles and flight equipment. The project developed a hybrid physical model concept that provided a structured approach to simplifying complex design models for use in health monitoring, allowing the output or performance of the equipment to be compared to what the design models predicted, so that deterioration or impending failure could be detected before there would be an impact on the equipment's operational capability. Based on the original modeling technology, Scientific Monitoring released I-Trend, a commercial health- and performance-monitoring software product named for its intelligent trending, diagnostics, and prognostics capabilities, as part of the company's complete ICEMS (Intelligent Condition-based Equipment Management System) suite of monitoring and advanced alerting software. I-Trend uses the hybrid physical model to better characterize the nature of health or performance alarms that result in "no fault found" false alarms. Additionally, the use of physical principles helps I-Trend identify problems sooner. I-Trend technology is currently in use in several commercial aviation programs, and the U.S. Air Force recently tapped Scientific Monitoring to develop next-generation engine health-management software for monitoring its fleet of jet engines. Scientific Monitoring has continued the original NASA work, this time under a Phase III SBIR contract with a joint NASA-Pratt & Whitney aviation security program on propulsion-controlled aircraft under missile-damaged aircraft conditions.
Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing
2016-01-01
The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients.
Monitoring of a steep rockfall area experiencing fast displacements in Kåfjord, Northern Norway
NASA Astrophysics Data System (ADS)
Dreiås Majala, Gudrun; Harald Blikra, Lars; Skrede, Ingrid; Kristensen, Lene
2016-04-01
An unstable rockfall area in Kåfjord, Northern Norway, was recognized during periodic monitoring campaigns in July and early September 2015. The LiSALab ground based Interferometric Synthethic Aperture Radar (GB InSAR) from Ellegi were used. A relatively sharply defined steep area of 1200 m2 (6.000 - 12.000 m3) was documented to be in movement. Norwegian Water Resources and Energy Directorate (NVE) was at this point performing mitigation work in terms of an embarkment within the rockfall run-out area. The monitoring system was reinstalled and adjusted to perform continuous monitoring with an early-warning aim. The section for rockslide management in NVE was responsible for the monitoring and the warning to the municipality and Police. The displacements increased from about 1 mm/day in July to 3 cm/day in mid September. People were evalcuated due to increased velocities the 16th of September. The displacements continued to increase in several stages, and with a distinct accelleration the 2nd of October. The velocity peaked in a short window to more than 200 cm/day, and it ended with a partly frontal and sideway collapse of the unstable area. However, large parts of the area stabilized again, and the run-out lengths from the small rockfalls were limited. The GB InSAR system operated exceptionally well during the event, and were able to follow continuously the displacements during the accelleration stage until collapse as the processing time window was frequently adjusted to the changes in velocity. We were also able to follow inidividual rockfalls from the images - primarily as the rockfall impact points on the slope below showed up clearly on the radar images. The area continued to stabilize due to falling temperatures, and the mitigation work were finished during the fall. The displacements seem to be correlated to the increasing temperatures in late summer and precipitation events.
29 CFR Appendix A to Subpart M of... - Determining Roof Widths
Code of Federal Regulations, 2013 CFR
2013-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... monitoring system alone as a means of providing fall protection during the performance of roofing operations...
29 CFR Appendix A to Subpart M of... - Determining Roof Widths
Code of Federal Regulations, 2014 CFR
2014-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... monitoring system alone as a means of providing fall protection during the performance of roofing operations...
29 CFR Appendix A to Subpart M of... - Determining Roof Widths
Code of Federal Regulations, 2010 CFR
2010-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... monitoring system alone as a means of providing fall protection during the performance of roofing operations...
29 CFR Appendix A to Subpart M of... - Determining Roof Widths
Code of Federal Regulations, 2012 CFR
2012-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... monitoring system alone as a means of providing fall protection during the performance of roofing operations...
29 CFR Appendix A to Subpart M of... - Determining Roof Widths
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fall Protection Pt. 1926... monitoring system alone as a means of providing fall protection during the performance of roofing operations...
40 CFR 63.7902 - What are my inspection and monitoring requirements for containers?
Code of Federal Regulations, 2010 CFR
2010-07-01
... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation Containers... this section, as applicable to your site remediation. (1) You must perform the verification procedure...
Nerve sparing sutureless total thyroidectomy. Preliminary study.
Parmeggiani, Domenico; De Falco, Massimo; Avenia, Nicola; Sanguinetti, Alessandro; Fiore, Andrea; Docimo, Giovanni; Ambrosino, Pasquale; Madonna, Imma; Peltrini, Roberto; Parmeggiani, Umberto
2012-01-01
In the present study the authors assess the advantages of new technologies in thyroid surgery: to prevent nerve injury by using an intra-operative continuous nerve-monitoring techniques and to compare the real advantages of advanced coagulation devices. Among a series of 440 thyroidectomies (jan 2004-feb 2006) the Authors reviewed charts from two groups: (1) 240 total thyroidectomies performed using the traditional monopolar electrocautery, non-absorbable stitches for the principal vascular pedicles. (2) 140 total thyroidectomies performed using dedicated small bipolar electro thermal coagulator (ligasure-precise). (3) Since 2006 in a double blind group selection of 70, we've performed sutureless thyroidectomy with continuous intraoperative nerve monitoring using dedicated endotracheal tube. Mean operative time, post-operative bleeding, post-operative stay, incidence of transient or definitive laryngeal nerve lesions, incidence of permanent or transient hypocalcaemia, costs of the procedures were analyzed. Major complications in the first two groups compared with the data of the literature are absolutely over-imposable, except a reduction of incidence of transient hypocalcaemia in the Precise group, but if we compare data of the 3rd group (NIM), we find a significative reduction of transient and permanent laryngeal nerve palsy incidence. This new technology offers several advantages: (1) atraumatic; (2) easy to use; (3) continuous monitoring and audio feedback to the surgeon (4) works outside the operation field (5) high sensitiveness. Cost-analysis confirm that NIM + ligasure have same or less cost and time and probably less complications than traditional Total Thyroidectomy.
40 CFR 60.3040 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.3040 Section 60.3040 Protection of Environment ENVIRONMENTAL... continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon... carbon monoxide. (b) You must install, evaluate, and operate each continuous emission monitoring system...
Operational experience of continuous air monitoring of smoke for ²³⁹Pu during a wildfire.
Whicker, Jeffrey J; Baltz, David; Eisele, William F; Hart, Orval F; McNaughton, Michael W; Green, Andrew A
2012-08-01
Smoke from a wildfire in northern New Mexico that moved along the border of the Los Alamos National Laboratory (LANL) was monitored for ²³⁹Pu in the event that the fire might cross into LANL property containing locations with low, but greater than background, levels of ²³⁹Pu and other alpha-emitting radionuclides. Three Environmental Continuous Air Monitors (ECAMs) in operation at LANL at the time of the fire provided near real-time measurements of the ²³⁹Pu in the smoke. Sampling data from routine measurements of PM-10 and PM-2.5 concentrations in the city of Los Alamos showed that smoke in the air rose during the fire to several hundred μg m⁻³, which produced limited visibility (several hundred meters) and resulted in poor air quality alerts for about a week-long period. Previous studies have shown that airborne dust can significantly impair continuous air monitors, so the purpose of this study was to assess the performance of the ECAMs under smoky conditions, which is important for many emergency response scenarios. Additionally, ECAMs are not required to be tested in smoke by ANSI standards, so there is little to no published data on performance of any ECAM while sampling smoke. Results show that the deployed ECAMs had reduced flow as the filter clogged with fine particles, but the goodness-of-fit parameter of the peak shape fitting algorithms and the minimum detectable concentration and dose were not impacted until the flow was reduced by more than about 20%, and even then they were within tolerable limits. Overall, ECAM performance was not impacted during the fire even under heavy smoke conditions and fluctuating radon levels, though changing the filters to limit any reductions in flow to less than 20% would maintain optimal ECAM performance.
Emerging Technologies for Real-Time Continuous Monitoring of Wellbore Integrity
NASA Astrophysics Data System (ADS)
Freifeld, B. M.
2017-12-01
Assessment of a well's integrity has traditionally been carried out through periodic wireline logging, often performed only when an operational problem was noted at the surface. There are several emerging technologies that can be installed permanently as part of the well completion and offer the ability to monitor operations while providing continuous indicators to evaluate the structural health of a well. Permanent behind casing instrumentation, such as pressure and temperature gauges can monitor for behind casing leakage. Similarly, fiber-optic distributed temperature and acoustic sensing provide additional information for assessing unwanted movement of fluid, which is indicative of problems either inside or outside of casing. Furthermore, these technologies offer the benefit of providing real-time continuous streams of information that serve as leading-indicators of wellbore problems to allow for early intervention. Additional research is still needed to develop best practices for the installation and operation of these technologies, as they increase cost and add additional risks that must be managed.
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring systems for sulfur dioxide, nitrogen...
Real-Time Management of Multimodal Streaming Data for Monitoring of Epileptic Patients.
Triantafyllopoulos, Dimitrios; Korvesis, Panagiotis; Mporas, Iosif; Megalooikonomou, Vasileios
2016-03-01
New generation of healthcare is represented by wearable health monitoring systems, which provide real-time monitoring of patient's physiological parameters. It is expected that continuous ambulatory monitoring of vital signals will improve treatment of patients and enable proactive personal health management. In this paper, we present the implementation of a multimodal real-time system for epilepsy management. The proposed methodology is based on a data streaming architecture and efficient management of a big flow of physiological parameters. The performance of this architecture is examined for varying spatial resolution of the recorded data.
Ultimate limits for quantum magnetometry via time-continuous measurements
NASA Astrophysics Data System (ADS)
Albarelli, Francesco; Rossi, Matteo A. C.; Paris, Matteo G. A.; Genoni, Marco G.
2017-12-01
We address the estimation of the magnetic field B acting on an ensemble of atoms with total spin J subjected to collective transverse noise. By preparing an initial spin coherent state, for any measurement performed after the evolution, the mean-square error of the estimate is known to scale as 1/J, i.e. no quantum enhancement is obtained. Here, we consider the possibility of continuously monitoring the atomic environment, and conclusively show that strategies based on time-continuous non-demolition measurements followed by a final strong measurement may achieve Heisenberg-limited scaling 1/{J}2 and also a monitoring-enhanced scaling in terms of the interrogation time. We also find that time-continuous schemes are robust against detection losses, as we prove that the quantum enhancement can be recovered also for finite measurement efficiency. Finally, we analytically prove the optimality of our strategy.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
... as of June 30 of the relevant year to monitor trends on an annual basis. To continue our time-series... video programming? 24. MVPD Performance. We seek comment on the information and time- series data we... Television Performance. We seek information and time- series data for the analysis of various performance...
Continuous Seismic Threshold Monitoring
1992-05-31
Continuous threshold monitoring is a technique for using a seismic network to monitor a geographical area continuously in time. The method provides...area. Two approaches are presented. Site-specific monitoring: By focusing a seismic network on a specific target site, continuous threshold monitoring...recorded events at the site. We define the threshold trace for the network as the continuous time trace of computed upper magnitude limits of seismic
Landsat still contributing to environmental research
Loveland, Thomas R.; Cochrane, Mark A.; Henebry, Geoffrey M.
2008-01-01
Landsat data have enabled continuous global monitoring of both human-caused and other land cover disturbances since 1972. Recently degraded performance and intermittent service of the Landsat 7 and Landsat 5 sensors, respectively, have raised concerns about the condition of global Earth observation programs. However, Landsat imagery is still useful for landscape change detection and this capability should continue into the foreseeable future.
APDS: Autonomous Pathogen Detection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langlois, R G; Brown, S; Burris, L
An early warning system to counter bioterrorism, the Autonomous Pathogen Detection System (APDS) continuously monitors the environment for the presence of biological pathogens (e.g., anthrax) and once detected, it sounds an alarm much like a smoke detector warns of a fire. Long before September 11, 2001, this system was being developed to protect domestic venues and events including performing arts centers, mass transit systems, major sporting and entertainment events, and other high profile situations in which the public is at risk of becoming a target of bioterrorist attacks. Customizing off-the-shelf components and developing new components, a multidisciplinary team developed APDS,more » a stand-alone system for rapid, continuous monitoring of multiple airborne biological threat agents in the environment. The completely automated APDS samples the air, prepares fluid samples in-line, and performs two orthogonal tests: immunoassay and nucleic acid detection. When compared to competing technologies, APDS is unprecedented in terms of flexibility and system performance.« less
40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I collect with my continuous emission monitoring systems and is this requirement enforceable? 62... with my continuous emission monitoring systems and is this requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the...
40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... collect with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2010 CFR
2010-07-01
... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...
Code of Federal Regulations, 2011 CFR
2011-07-01
... must I collect with my continuous parameter monitoring systems and is this requirement enforceable? 62... with my continuous parameter monitoring systems and is this requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1...
40 CFR 62.15180 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems used? 62.15180 Section 62.15180 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Continuous Emission Monitoring § 62.15180 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems, and is the data collection... with my continuous emission monitoring systems, and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure...
40 CFR 60.1725 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems used? 60.1725 Section 60.1725 Protection of Environment ENVIRONMENTAL... Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1725 How are the data from the continuous emission monitoring systems used? You must use data from the continuous emission monitoring...
Li, Gen; Ma, Ke; Sun, Jian; Jin, Gui; Qin, Mingxin; Feng, Hua
2017-01-01
Cerebral edema is a common disease, secondary to craniocerebral injury, and real-time continuous monitoring of cerebral edema is crucial for treating patients after traumatic brain injury. This work established a noninvasive and noncontact system by monitoring the magnetic induction phase shift (MIPS) which is associated with brain tissue conductivity. Sixteen rabbits (experimental group n = 10, control group, n = 6) were used to perform a 24 h MIPS and intracranial pressure (ICP) simultaneously monitored experimental study. For the experimental group, after the establishment of epidural freeze-induced cerebral edema models, the MIPS presented a downward trend within 24 h, with a change magnitude of −13.1121 ± 2.3953°; the ICP presented an upward trend within 24 h, with a change magnitude of 12–41 mmHg. The ICP was negatively correlated with the MIPS. In the control group, the MIPS change amplitude was −0.87795 ± 1.5146 without obvious changes; the ICP fluctuated only slightly at the initial value of 12 mmHg. MIPS had a more sensitive performance than ICP in the early stage of cerebral edema. These results showed that this system is basically capable of monitoring gradual increases in the cerebral edema solution volume. To some extent, the MIPS has the potential to reflect the ICP changes. PMID:28282851
Code of Federal Regulations, 2014 CFR
2014-07-01
... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...
Code of Federal Regulations, 2013 CFR
2013-07-01
... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...
USDA-ARS?s Scientific Manuscript database
Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...
Sparacino, Giovanni; Zanon, Mattia; Facchinetti, Andrea; Zecchin, Chiara; Maran, Alberto; Cobelli, Claudio
2012-01-01
Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community. PMID:23202020
Sparacino, Giovanni; Zanon, Mattia; Facchinetti, Andrea; Zecchin, Chiara; Maran, Alberto; Cobelli, Claudio
2012-10-12
Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.
APDS: the autonomous pathogen detection system.
Hindson, Benjamin J; Makarewicz, Anthony J; Setlur, Ujwal S; Henderer, Bruce D; McBride, Mary T; Dzenitis, John M
2005-04-15
We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic acid-based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for 7 days in a major U.S. transportation hub is reported.
On predicting monitoring system effectiveness
NASA Astrophysics Data System (ADS)
Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo
2015-03-01
While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.
NASA Astrophysics Data System (ADS)
Schmidt, J. B.
1985-09-01
This thesis investigates ways of improving the real-time performance of the Stockpoint Logistics Integrated Communication Environment (SPLICE). Performance evaluation through continuous monitoring activities and performance studies are the principle vehicles discussed. The method for implementing this performance evaluation process is the measurement of predefined performance indexes. Performance indexes for SPLICE are offered that would measure these areas. Existing SPLICE capability to carry out performance evaluation is explored, and recommendations are made to enhance that capability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... must collect with my continuous parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... I must collect with my continuous emission monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages...
Leal, Yenny; Gonzalez-Abril, Luis; Lorencio, Carol; Bondia, Jorge; Vehi, Josep
2013-07-01
Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources AGENCY... direct final rule titled ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA...
Chen, Yin-Chun; Huang, Yu-Yao; Li, Hung-Yuan; Liu, Shih-Wei; Hsieh, Sheng-Hwu; Lin, Chia-Hung
2015-01-01
The identification of type 1 diabetes in diabetic subjects receiving insulin therapy is sometimes difficult. The purpose of this study is to evaluate whether results of professional continuous glucose monitoring can improve the identification of type 1 diabetes.From 2007 to 2012, 119 adults receiving at least twice-daily insulin therapy and professional continuous glucose monitoring were recruited. Type 1 diabetes was diagnosed by endocrinologists according to American Diabetes Association standards, including a very low C-peptide level (<0.35 pg/mL) or the presence of diabetic ketoacidosis. Continuous glucose monitoring was applied for 3 days.Among 119 subjects, 86 were diagnosed with type 1 diabetes. Subjects with type 1 diabetes were younger (33.8 vs 52.3 years old, P < 0.001), had lower body mass index (BMI, 21.95 vs 24.42, P = 0.003), lower serum creatinine (61.77 vs 84.65 μmol/L, P = 0.001), and higher estimated glomerular filtration rate (108.71 vs 76.48 mg/mL/min/1.73m2, P < 0.001) than subjects with type 2 diabetes. Predictive scores for identification of type 1 diabetes were constructed, including age, BMI, average mean amplitude of glucose excursion in days 2 and 3, and the area under the curve of nocturnal hyperglycemic and hypoglycemic states. The area under the receiver operating characteristic curve was 0.90. With the cutoff of 0.58, the sensitivity was 86.7% and the specificity was 80.8%. The good performance was validated by the leave-one-out method (sensitivity 83.3%, specificity 73.1%).Professional continuous glucose monitoring is a useful tool that improves identification of type 1 diabetes among diabetic patients receiving insulin therapy.
Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro
2015-12-01
Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
The Timer-Logger-Communicator for Continuous, Mobile Measurement of Wheelchair Pressure Reliefs
Grip, Jeffrey C.; Merbitz, Charles T.
1985-01-01
A recently developed device which provides continuous, direct monitoring of the pressure-relief performance of persons confined to wheelchairs is reported. A custom portable computer records the data, which is transferred for analysis to an Apple IIe. The mobile computer can also signal the patient to relieve pressure based on preset criteria and the patient's performance. Teaching lift-offs to prevent ischial pressure sores is the object. Data collected with the device are used clinically and for research. Examples of such data are presented. The benefits of the device are reviewed.
Long-Term Monitoring of Pavement Maintenance Materials Test Sites
DOT National Transportation Integrated Search
1998-06-01
The Strategic Highway Research Program's {SHRP) H-106 pothole repair experiment was part of the most extensive pavement maintenance experiment ever conducted. Started under SHRP and continued under the Long-Term Pavement Performance program's Long-Te...
Long-Term Pavement Performance Program
DOT National Transportation Integrated Search
2015-12-01
The LTPP program will yield additional benefits as data are added to the database and as data analysis effortssome currently planned and some yet to be identifiedare completed. Continued monitoring of the test sections that remain in service is...
Applications and Methods for Continuous Monitoring of Physiological Chemistry
2016-02-04
product and test platform to verify the performance characteristics of the enzymes when used in diagnostic device fabrication. 1.3 Results This...project had three primary objectives: 1. Engineer a cortisol oxidase enzyme suitable for use in diagnostic devices 2. Large scale production and...for both animal and human use , and for direct sale to other entities to manufacture biosensors and other products for human monitoring. The enzymes
Fluidized Bed Boiler Assessment for Navy Applications
1986-11-01
rather than removing it from the flue gas later with "scrubbing" devices. Intro- duction of limestone in the bed will reduce SO emissions; two...boiler in a satisfactory manner, the bed level, combustion temperature, and the flue gas composition and temperature should be continuously monitored...The flue gas composition should be c^-ɝely monitored for pollutants and combustion efficiency. EVOLUTION OF FBC BOILERS The performance of FBC
Ferreira, J; Seoane, F; Lindecrantz, K
2013-01-01
Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.
Progress toward an advanced condition monitoring system for reusable rocket engines
NASA Technical Reports Server (NTRS)
Maram, J.; Barkhoudarian, S.
1987-01-01
A new generation of advanced sensor technologies will allow the direct measurement of critical/degradable rocket engine components' health and the detection of degraded conditions before component deterioration affects engine performance, leading to substantial improvements in reusable engines' operation and maintenance. When combined with a computer-based engine condition-monitoring system, these sensors can furnish a continuously updated data base for the prediction of engine availability and advanced warning of emergent maintenance requirements. Attention is given to the case of a practical turbopump and combustion device diagnostic/prognostic health-monitoring system.
Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring.
Sharma, Sanjiv; Huang, Zhenyi; Rogers, Michelle; Boutelle, Martyn; Cass, Anthony E G
2016-11-01
We describe here a minimally invasive glucose biosensor based on a microneedle array electrode fabricated from an epoxy-based negative photoresist (SU8 50) and designed for continuous measurement in the dermal compartment with minimal pain. These minimally invasive, continuous monitoring sensor devices (MICoMS) were produced by casting the structures in SU8 50, crosslinking and then metallising them with platinum or silver to obtain the working and reference electrodes, respectively. The metallised microneedle array electrodes were subsequently functionalised by entrapping glucose oxidase in electropolymerised polyphenol (PP) film. Sensor performance in vitro showed that glucose concentrations down to 0.5 mM could be measured with a response times (T 90 ) of 15 s. The effect of sterilisation by Co60 irradiation was evaluated. In preparation for further clinical studies, these sensors were tested in vivo in a healthy volunteer for a period of 3-6 h. The sensor currents were compared against point measurements obtained with a commercial capillary blood glucometer. The epoxy MICoMS devices showed currents values that could be correlated with these. Graphical Abstract Microneedle arrays for continuous glucose monitoring in dermal interstitial fluid.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 60.1270 Section 60.1270 Protection of Environment... Continuous Emission Monitoring § 60.1270 What is required for my continuous opacity monitoring system and how... system. (b) Install, evaluate, and operate each continuous opacity monitoring system according to § 60.13...
Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology.
Hoss, Udo; Budiman, Erwin Satrya
2017-05-01
The use of commercially available continuous glucose monitors for diabetes management requires sensor calibrations, which until recently are exclusively performed by the patient. A new development is the implementation of factory calibration for subcutaneous glucose sensors, which eliminates the need for user calibrations and the associated blood glucose tests. Factory calibration means that the calibration process is part of the sensor manufacturing process and performed under controlled laboratory conditions. The ability to move from a user calibration to factory calibration is based on several technical requirements related to sensor stability and the robustness of the sensor manufacturing process. The main advantages of factory calibration over the conventional user calibration are: (a) more convenience for the user, since no more fingersticks are required for calibration and (b) elimination of use errors related to the execution of the calibration process, which can lead to sensor inaccuracies. The FreeStyle Libre ™ and FreeStyle Libre Pro ™ flash continuous glucose monitoring systems are the first commercially available sensor systems using factory-calibrated sensors. For these sensor systems, no user calibrations are required throughout the sensor wear duration.
Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology
Budiman, Erwin Satrya
2017-01-01
Abstract The use of commercially available continuous glucose monitors for diabetes management requires sensor calibrations, which until recently are exclusively performed by the patient. A new development is the implementation of factory calibration for subcutaneous glucose sensors, which eliminates the need for user calibrations and the associated blood glucose tests. Factory calibration means that the calibration process is part of the sensor manufacturing process and performed under controlled laboratory conditions. The ability to move from a user calibration to factory calibration is based on several technical requirements related to sensor stability and the robustness of the sensor manufacturing process. The main advantages of factory calibration over the conventional user calibration are: (a) more convenience for the user, since no more fingersticks are required for calibration and (b) elimination of use errors related to the execution of the calibration process, which can lead to sensor inaccuracies. The FreeStyle Libre™ and FreeStyle Libre Pro™ flash continuous glucose monitoring systems are the first commercially available sensor systems using factory-calibrated sensors. For these sensor systems, no user calibrations are required throughout the sensor wear duration. PMID:28541139
Site environmental report for Calendar Year 1994 on radiological and nonradiological parameters
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-30
Battelle Memorial Institute`s nuclear research facilities are currently being maintained in a surveillance and maintenance (S&M) mode with continual decontamination and decommissioning (D&D) activities being conducted under Department of Energy (DOE) Contract W-7405-ENG-92. These activities are referred to under the Contract as the Battelle Columbus Laboratories Decommissioning Project (BCLDP). Operations referenced in this report are performed in support of S&M and D&D activities. Battelle`s King Avenue facility is not considered in this report to the extent that the West Jefferson facility is. The source term at the King Avenue site is a small fraction of the source term at themore » West Jefferson site. Off site levels of radionuclides that could be attributed to the west Jefferson and King Avenue nuclear operations wereindistinguishable from background levels at specific locations where air, water, and direct radiation measurements were performed. Environmental monitoring continued to demonstrate compliance by Battelle with federal, state and local regulations. Routine, nonradiological activities performed include monitoring liquid effluents and monitoring the ground water system for the West Jefferson North site. Samples of various environmental media including air, water, grass, fish, field and garden crops, sediment and soil were collected from the region surrounding the two sites and analyzed.« less
Poca, M; Sahuquillo, J
2001-01-01
The study of cerebrospinal fluid (CSF) dynamics is central to the diagnosis of adult chronic hydrocephalus (ACH). At present, many neurology and neurosurgery departments use one or more tests to guide diagnosis of this syndrome and to predict patient response to shunting. In specialised centres, the study of CSF dynamics is combined with continuous intracranial pressure (ICP) monitoring. Determination of several variables of CSF dynamics and definitions of qualitative and quantitative characteristics of ICP can be used to establish whether the hydrocephalus is active, compensated or arrested. CSF dynamics and ICP monitoring can also be used to check the correct functioning of the shunt and can be of use in the clinical management of patients with pseudotumor cerebri. Moreover, ICP monitoring is used to guide the treatment of several acute neurological processes. The aim of this review is to describe the fundamentals of CSF dynamics studies and the bases of continuous ICP monitoring. The advantages and disadvantages of several hydrodynamic tests that can be performed by lumbar puncture, as well as the normal and abnormal characteristics of an ICP recording, are discussed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...
Code of Federal Regulations, 2012 CFR
2012-07-01
... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliance for NOX if I do not use water or steam injection? 60.4340 Section 60.4340 Protection of... NEW STATIONARY SOURCES Standards of Performance for Stationary Combustion Turbines Monitoring § 60.4340 How do I demonstrate continuous compliance for NOX if I do not use water or steam injection? (a...
Murphy, Jennifer C.; Farmer, James; Layton, Alice
2016-06-13
The U.S. Geological Survey, in cooperation with the Tennessee Duck River Development Agency, monitored water quality at several locations in the upper Duck River watershed between October 2007 and September 2010. Discrete water samples collected at 24 sites in the watershed were analyzed for water quality, and Escherichia coli (E. coli) and enterococci concentrations. Additional analyses, including the determination of anthropogenic-organic compounds, bacterial concentration of resuspended sediment, and bacterial-source tracking, were performed at a subset of sites. Continuous monitoring of streamflow, turbidity, and specific conductance was conducted at seven sites; a subset of sites also was monitored for water temperature and dissolved oxygen concentration. Multiple-regression models were developed to predict instantaneous E. coli concentrations and loads at sites with continuous monitoring. This data collection effort, along with the E. coli models and predictions, support analyses of the relations among land use, bacteria source and transport, and basin hydrology in the upper Duck River watershed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
40 CFR 60.1235 - How are the data from the continuous emission monitoring systems used?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems used? 60.1235 Section 60.1235 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1235 How are the data from the continuous emission monitoring systems... oxides, and carbon monoxide to demonstrate continuous compliance with the emission limits specified in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Continuous methane monitoring device... Installations § 77.211-1 Continuous methane monitoring device; installation and operation; automatic deenergization of electric equipment. Continuous methane monitoring devices shall be set to deenergize...
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2011 CFR
2011-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
40 CFR 60.3038 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2010 CFR
2010-07-01
... December 9, 2004 Model Rule-Monitoring § 60.3038 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for... system according to the “Monitoring Requirements” in § 60.13. ...
International Space Station Major Constituent Analyzer On-Orbit Performance
NASA Technical Reports Server (NTRS)
Gardner, Ben D.; Erwin, Phillip M.; Thoresen, Souzan; Wiedemann, Rachel; Matty, Chris
2015-01-01
The Major Constituent Analyzer is a mass spectrometer based system that measures the major atmospheric constituents on the International Space Station. A number of limited-life components require periodic change-out, including the ORU 02 analyzer and the ORU 08 Verification Gas Assembly. Improvements to ion pump operation and ion source tuning have improved lifetime performance of the current ORU 02 design. The most recent ORU 02 analyzer assemblies, as well as ORU 08, have operated nominally. For ORU 02, the ion source filaments and ion pump lifetime continue to be key determinants of MCA performance and logistical support. Monitoring several key parameters provides the capacity to monitor ORU health and properly anticipate end of life.
Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing
2016-01-01
Objectives The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. Methods A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Results Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Conclusion Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients. PMID:27093294
Downey, C L; Brown, J M; Jayne, D G; Randell, R
2018-06-01
Vital signs monitoring is used to identify deteriorating patients in hospital. The most common tool for vital signs monitoring is an early warning score, although emerging technologies allow for remote, continuous patient monitoring. A number of reviews have examined the impact of continuous monitoring on patient outcomes, but little is known about the patient experience. This study aims to discover what patients think of monitoring in hospital, with a particular emphasis on intermittent early warning scores versus remote continuous monitoring, in order to inform future implementations of continuous monitoring technology. Semi-structured interviews were undertaken with 12 surgical inpatients as part of a study testing a remote continuous monitoring device. All patients were monitored with both an early warning score and the new device. Interviews were audio-recorded, transcribed verbatim and analysed using thematic analysis. Patients can see the value in remote, continuous monitoring, particularly overnight. However, patients appreciate the face-to-face aspect of early warning score monitoring as it allows for reassurance, social interaction, and gives them further opportunity to ask questions about their medical care. Early warning score systems are widely used to facilitate detection of the deteriorating patient. Continuous monitoring technologies may provide added reassurance. However, patients value personal contact with their healthcare professionals and remote monitoring should not replace this. We suggest that remote monitoring is best introduced in a phased manner, and initially as an adjunct to usual care, with careful consideration of the patient experience throughout. Copyright © 2018 Elsevier B.V. All rights reserved.
Planning Risk-Based SQC Schedules for Bracketed Operation of Continuous Production Analyzers.
Westgard, James O; Bayat, Hassan; Westgard, Sten A
2018-02-01
To minimize patient risk, "bracketed" statistical quality control (SQC) is recommended in the new CLSI guidelines for SQC (C24-Ed4). Bracketed SQC requires that a QC event both precedes and follows (brackets) a group of patient samples. In optimizing a QC schedule, the frequency of QC or run size becomes an important planning consideration to maintain quality and also facilitate responsive reporting of results from continuous operation of high production analytic systems. Different plans for optimizing a bracketed SQC schedule were investigated on the basis of Parvin's model for patient risk and CLSI C24-Ed4's recommendations for establishing QC schedules. A Sigma-metric run size nomogram was used to evaluate different QC schedules for processes of different sigma performance. For high Sigma performance, an effective SQC approach is to employ a multistage QC procedure utilizing a "startup" design at the beginning of production and a "monitor" design periodically throughout production. Example QC schedules are illustrated for applications with measurement procedures having 6-σ, 5-σ, and 4-σ performance. Continuous production analyzers that demonstrate high σ performance can be effectively controlled with multistage SQC designs that employ a startup QC event followed by periodic monitoring or bracketing QC events. Such designs can be optimized to minimize the risk of harm to patients. © 2017 American Association for Clinical Chemistry.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the option in paragraph (a)(1)(iii) in § 63.1564 (Ni lb/hr), and you use continuous parameter monitoring systems, you must establish an operating limit for the equilibrium catalyst Ni concentration based on the laboratory analysis of the equilibrium catalyst Ni concentration from the initial performance...
Nielsen, R G; Wilson, G S
1987-12-25
Low-level adsorption on the stationary phase has been studied using immunochemical reagents. An immunoaffinity column has been evaluated using affinity-purified radioisotope-labeled monoclonal antibodies. Recovery experiments including continuous immunosorbent monitoring have been performed. Proper characterization of an immunoaffinity separation can result in the recovery of immunologically active material in high yield.
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes.
Slattery, David; Choudhary, Pratik
2017-05-01
With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important diagnostic and therapeutic option in optimizing diabetes management. CGM systems are now more accurate, smaller, and easier to use compared to original models. Randomized controlled trials (RCTs) have demonstrated that CGM can improve Hemoglobin A1c (HbA1C) and reduce glucose variability in both continuous subcutaneous insulin infusion and multiple daily injection users. When used in an automated "insulin-suspend" system, reduced frequency of hypoglycemia and shorter time spent in hypoglycemic range have been demonstrated. Despite the potential benefits CGM has to offer in clinical practice, concerns exist on the accuracy of these devices and patient compliance with therapy, which may prevent the true clinical benefit of CGM being achieved, as observed in RCTs. Flash glucose monitoring systems FreeStyle ® Libre™ (Abbott Diabetes Care, Alameda, CA) are as accurate as many CGM systems available and have the added benefit of being factory calibrated. Studies have shown that flash glucose monitoring systems are very well tolerated by patients and effectively reduce glucose variability, increasing time in range.
40 CFR 60.2941 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.2941 Section 60.2941 Protection of Environment ENVIRONMENTAL... emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems... emission monitoring systems daily and quarterly as specified in appendix F of this part. ...
DOT National Transportation Integrated Search
2001-11-01
For concrete rehabilitation, application of fiber reinforced polymer composites continues to grow in popularity. However, performance and expected lifetime of such rehabilitation measures are greatly depending on quality of workmanship and are jeopar...
Code of Federal Regulations, 2011 CFR
2011-07-01
... per million dry volume absolute value of the mean difference between the method and the continuous... activities (including, as applicable, calibration checks and required zero and span adjustments). Any such...
Vehicle-based drowsy driver detection : current status and future prospects
DOT National Transportation Integrated Search
1994-01-01
Driver drowsiness is a major, though elusive, cause of traffic crashes. As part of its : IVHS/human factors program, NHTSA is supporting research to develop in-vehicle systems . : to continuously monitor driver alertness and performance. Scientific s...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use...
Radüntz, Thea
2017-01-01
One goal of advanced information and communication technology is to simplify work. However, there is growing consensus regarding the negative consequences of inappropriate workload on employee's health and the safety of persons. In order to develop a method for continuous mental workload monitoring, we implemented a task battery consisting of cognitive tasks with diverse levels of complexity and difficulty. We conducted experiments and registered the electroencephalogram (EEG), performance data, and the NASA-TLX questionnaire from 54 people. Analysis of the EEG spectra demonstrates an increase of the frontal theta band power and a decrease of the parietal alpha band power, both under increasing task difficulty level. Based on these findings we implemented a new method for monitoring mental workload, the so-called Dual Frequency Head Maps (DFHM) that are classified by support vectors machines (SVMs) in three different workload levels. The results are in accordance with the expected difficulty levels arising from the requirements of the tasks on the executive functions. Furthermore, this article includes an empirical validation of the new method on a secondary subset with new subjects and one additional new task without any adjustment of the classifiers. Hence, the main advantage of the proposed method compared with the existing solutions is that it provides an automatic, continuous classification of the mental workload state without any need for retraining the classifier—neither for new subjects nor for new tasks. The continuous workload monitoring can help ensure good working conditions, maintain a good level of performance, and simultaneously preserve a good state of health. PMID:29276490
Zhong, D; Zhou, Y; Li, Y; Wang, Y; Zhou, W; Cheng, Q; Chen, L; Zhao, J; Li, X; Yan, X
2014-07-01
It is well accepted that recurrent laryngeal nerve paralysis is a severe complication of esophagectomy or lymphadenectomy performed adjacent to the recurrent laryngeal nerves. Herein, determination of the effectiveness of implementing continuous recurrent laryngeal nerve monitoring to reduce the incidence of recurrent laryngeal nerve paralysis after esophagectomy was sought. A total of 115 patients diagnosed with esophageal cancer were enrolled in the thoracic section of the Tangdu Hospital of the Fourth Military Medical University from April 2008 to April 2009. Clinical parameters of patients, the morbidity, and the mortality following esophageal resection were recorded and compared. After the surgery, a 2-year follow up was completed. It was found that recurrent laryngeal nerve paralysis and postoperative pneumonia were more frequently diagnosed in the patients that did not receive continuous recurrent laryngeal nerve monitoring (6/61 vs. 0/54). Furthermore, positive mediastinal lymph nodes (P = 0.015), total mediastinal lymph nodes (P < 0.001), positive total lymph nodes (P = 0.027), and total lymph nodes (P < 0.001) were more often surgically removed in the patients with continuous recurrent laryngeal nerve monitoring. These patients also had a higher 2-year survival rate (P = 0.038) after surgery. It was concluded that continuous intraoperative recurrent laryngeal nerve monitoring is technically safe and effectively identifies the recurrent laryngeal nerves. This may be a helpful method for decreasing the incidence of recurrent laryngeal nerve paralysis and postoperative pneumonia, and for improving the efficiency of lymphadenectomy. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Peters, Johanna; Teske, Andreas; Taute, Wolfgang; Döscher, Claas; Höft, Michael; Knöchel, Reinhard; Breitkreutz, Jörg
2018-02-15
The trend towards continuous manufacturing in the pharmaceutical industry is associated with an increasing demand for advanced control strategies. It is a mandatory requirement to obtain reliable real-time information on critical quality attributes (CQA) during every process step as the decision on diversion of material needs to be performed fast and automatically. Where possible, production equipment should provide redundant systems for in-process control (IPC) measurements to ensure continuous process monitoring even if one of the systems is not available. In this paper, two methods for real-time monitoring of granule moisture in a semi-continuous fluid-bed drying unit are compared. While near-infrared (NIR) spectroscopy has already proven to be a suitable process analytical technology (PAT) tool for moisture measurements in fluid-bed applications, microwave resonance technology (MRT) showed difficulties to monitor moistures above 8% until recently. The results indicate, that the newly developed MRT sensor operating at four resonances is capable to compete with NIR spectroscopy. While NIR spectra were preprocessed by mean centering and first derivative before application of partial least squares (PLS) regression to build predictive models (RMSEP = 0.20%), microwave moisture values of two resonances sufficed to build a statistically close multiple linear regression (MLR) model (RMSEP = 0.07%) for moisture prediction. Thereby, it could be verified that moisture monitoring by MRT sensor systems could be a valuable alternative to NIR spectroscopy or could be used as a redundant system providing great ease of application. Copyright © 2017 Elsevier B.V. All rights reserved.
Salinas, Maria; López-Garrigós, Maite; Gutiérrez, Mercedes; Lugo, Javier; Sirvent, Jose Vicente; Uris, Joaquin
2010-01-01
Laboratory performance can be measured using a set of model key performance indicators (KPIs). The design and implementation of KPIs are important issues. KPI results from 7 years are reported and their implementation, monitoring, objectives, interventions, result reporting and delivery are analyzed. The KPIs of the entire laboratory process were obtained using Laboratory Information System (LIS) registers. These were collected automatically using a data warehouse application, spreadsheets and external quality program reports. Customer satisfaction was assessed using surveys. Nine model laboratory KPIs were proposed and measured. The results of some examples of KPIs used in our laboratory are reported. Their corrective measurements or the implementation of objectives led to improvement in the associated KPIs results. Measurement of laboratory performance using KPIs and a data warehouse application that continuously collects registers and calculates KPIs confirmed the reliability of indicators, indicator acceptability and usability for users, and continuous process improvement.
Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
Bin, Na-Ryum; Song, Hongmei; Wu, Chiping; Lau, Marcus; Sugita, Shuzo; Eubanks, James H.; Zhang, Liang
2017-01-01
We describe here a simple, cost-effective apparatus for continuous tethered electroencephalographic (EEG) monitoring of spontaneous recurrent seizures in mice. We used a small, low torque slip ring as an EEG commutator, mounted the slip ring onto a standard mouse cage and connected rotary wires of the slip ring directly to animal's implanted headset. Modifications were made in the cage to allow for a convenient installation of the slip ring and accommodation of animal ambient activity. We tested the apparatus for hippocampal EEG recordings in adult C57 black mice. Spontaneous recurrent seizures were induced using extended hippocampal kindling (≥95 daily stimulation). Control animals underwent similar hippocampal electrode implantations but no stimulations were given. Combined EEG and webcam monitoring were performed for 24 h daily for 5–9 consecutive days. During the monitoring periods, the animals moved and accessed water and food freely and showed no apparent restriction in ambient cage activities. Ictal-like hippocampal EEG discharges and concurrent convulsive behaviors that are characteristics of spontaneous recurrent seizures were reliably recorded in a majority of the monitoring experiments in extendedly kindled but not in control animals. However, 1–2 rotary wires were disconnected from the implanted headset in some animals after continuous recordings for ≥5 days. The key features and main limitations of our recording apparatus are discussed. PMID:28959196
Outcomes of Subdural Grid Electrode Monitoring in the Stereoelectroencephalography Era.
Mullin, Jeffrey P; Sexton, Daniel; Al-Omar, Soha; Bingaman, William; Gonzalez-Martinez, Jorge
2016-05-01
Subdural grid (SDG) electrodes have been the gold standard of invasive monitoring in medically refractory epilepsy; however, in some centers, application of SDGs has been reduced by the progressive application of stereoelectroencephalography (SEEG). This study reviews the efficacy of SDG electrode monitoring after the incorporation of the SEEG methodology at our institution. We retrospectively reviewed 102 patients undergoing intracranial monitoring via SDG electrodes during the years 2010-2013 at our institution. The series includes all patients who underwent SDG placement after the incorporation of SEEG in our extraoperative invasive monitoring armamentarium. Average patient age was 29.9 years old; the series included 31 pediatric patients. There were 49 male patients and 53 female patients. The mean length of follow-up was 21.5 months. The epileptogenic zone was localized in 99 (97%) patients. Surgical resection was performed in 84 patients, and 70% experienced Engel class I freedom from seizures. Invasive monitoring via SDG electrodes continues to be an efficacious option for select patients with medically refractory epilepsy, mainly when the hypothetical epileptogenic zone is anatomically restricted to superficial cortical areas and in close relation with eloquent cortex. This is the first report of epilepsy outcomes after SDG monitoring at a center that also performs SEEG monitoring. Our results suggest a complementary benefit of performing both techniques at 1 institution. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Jacobson, Gloria; Rella, Chris; Farinas, Alejandro
2014-05-01
Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits of Signal Averaging in Atmospheric Trace-Gas Monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS)," Applied Physics, B57, pp 131-139, April 1993
Sachat, Alexandros El; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos
2017-03-11
Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3-11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants' ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications.
El Sachat, Alexandros; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos
2017-01-01
Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3–11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants’ ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications. PMID:28287488
Future United States Role in European Security
1992-08-26
MONITORING ORGANIZATION REPORT NUMBER(S) 6a. NAME OF PERFORMING ORGANIZATION 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION US Army War College (if...necessary and identify by block number) FIELD GROUP SUB- GROUP 19, ABSTRACT (Continue on reverse if necessary and identify by block number) See reverse...concerning these forces: Of course, they used NATO rules of engagement and worked to NATO standards. They had trained together as NATO forces and
Miniaturized pulse oximeter sensor for continuous vital parameter monitoring
NASA Astrophysics Data System (ADS)
Fiala, Jens; Reichelt, Stephan; Werber, Armin; Bingger, Philipp; Zappe, Hans; Förster, Katharina; Klemm, Rolf; Heilmann, Claudia; Beyersdorf, Friedhelm
2007-07-01
A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cu. which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.
Okamura, Naomi; Kobayashi, Yo; Sugano, Shigeki; Fujie, Masakatsu G
2017-07-01
Static stretching is widely performed to decrease muscle tone as a part of rehabilitation protocols. Finding out the optimal duration of static stretching is important to minimize the time required for rehabilitation therapy and it would be helpful for maintaining the patient's motivation towards daily rehabilitation tasks. Several studies have been conducted for the evaluation of static stretching; however, the recommended duration of static stretching varies widely between 15-30 s in general, because the traditional methods for the assessment of muscle tone do not monitor the continuous change in the target muscle's state. We have developed a method to monitor the viscoelasticity of one muscle continuously during static stretching, using a wearable indentation tester. In this study, we investigated a suitable signal processing method to detect the time required to change the muscle tone, utilizing the data collected using a wearable indentation tester. By calculating a viscoelastic index with a certain time window, we confirmed that the stretching duration required to bring about a decrease in muscle tone could be obtained with an accuracy in the order of 1 s.
Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz
2015-04-01
Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.
2012-06-01
GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND...8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR...challenges, our commitment to reduce costs even as we continue to improve performance , and DLA’s enduring partnerships within and external to the Defense
Cronin, Edmond M; Varma, Niraj
2012-07-01
Traditional follow-up of cardiac implantable electronic devices involves the intermittent download of largely nonactionable data. Remote monitoring represents a paradigm shift from episodic office-based follow-up to continuous monitoring of device performance and patient and disease state. This lessens device clinical burden and may also lead to cost savings, although data on economic impact are only beginning to emerge. Remote monitoring technology has the potential to improve the outcomes through earlier detection of arrhythmias and compromised device integrity, and possibly predict heart failure hospitalizations through integration of heart failure diagnostics and hemodynamic monitors. Remote monitoring platforms are also huge databases of patients and devices, offering unprecedented opportunities to investigate real-world outcomes. Here, the current status of the field is described and future directions are predicted.
Lieberman, Harris R; Kramer, F Matthew; Montain, Scott J; Niro, Philip
2007-05-01
Limited opportunities to study human cognitive performance in non-laboratory, ambulatory situations exist. However, advances in technology make it possible to extend behavioral assessments to the field. One of the first devices to measure human behavior in the field was the wrist-worn actigraph. This device acquires minute-by-minute information on an individual's physical activity and can distinguish sleep from waking, the most basic aspect of behavior. Our laboratory developed a series of wrist-worn devices, not much larger than a watch, which assess reaction time, vigilance and memory. The devices concurrently assess motor activity with greater temporal resolution than standard actigraphs. They also continuously monitor multiple environmental variables including temperature, humidity, sound, and light. These monitors have been employed during training and simulated military operations to collect behavioral and environmental information that would typically be unavailable under such circumstances. Development of the vigilance monitor, and how each successive version extended capabilities of the device are described. Data from several studies are presented, including studies conducted in harsh field environments during a simulated infantry assault, an officer training course. The monitors simultaneously documented environmental conditions, patterns of sleep and activity and effects of nutritional manipulations on cognitive performance. They provide a new method to relate cognitive performance to real world environmental conditions and assess effects of various interventions on human behavior in the field. They can also monitor cognitive performance in real time, and if it is degraded, attempt to intervene to maintain
Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.
Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe
2014-01-01
As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.
Large Scale Application of Vibration Sensors for Fan Monitoring at Commercial Layer Hen Houses
Chen, Yan; Ni, Ji-Qin; Diehl, Claude A.; Heber, Albert J.; Bogan, Bill W.; Chai, Li-Long
2010-01-01
Continuously monitoring the operation of each individual fan can significantly improve the measurement quality of aerial pollutant emissions from animal buildings that have a large number of fans. To monitor the fan operation by detecting the fan vibration is a relatively new technique. A low-cost electronic vibration sensor was developed and commercialized. However, its large scale application has not yet been evaluated. This paper presents long-term performance results of this vibration sensor at two large commercial layer houses. Vibration sensors were installed on 164 fans of 130 cm diameter to continuously monitor the fan on/off status for two years. The performance of the vibration sensors was compared with fan rotational speed (FRS) sensors. The vibration sensors exhibited quick response and high sensitivity to fan operations and therefore satisfied the general requirements of air quality research. The study proved that detecting fan vibration was an effective method to monitor the on/off status of a large number of single-speed fans. The vibration sensor itself was $2 more expensive than a magnetic proximity FRS sensor but the overall cost including installation and data acquisition hardware was $77 less expensive than the FRS sensor. A total of nine vibration sensors failed during the study and the failure rate was related to the batches of product. A few sensors also exhibited unsteady sensitivity. As a new product, the quality of the sensor should be improved to make it more reliable and acceptable. PMID:22163544
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity monitoring system and how are the data used? 60.1760 Section 60.1760 Protection of Environment... continuous opacity monitoring system and how are the data used? (a) Install, calibrate, maintain, and operate a continuous opacity monitoring system. (b) Install, evaluate, and operate each continuous opacity...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems Use the following methods in appendix A of this part to validate poollutant concentratin...
Cardiopulmonary Laboratory AFSC 904X0
1990-10-01
SET UP POSITIVE END EXPIRATORY PRESSURE (PEEP) DEVICES 100 J321 SET UP CONTINUOUS POSITIVE AIRWAY PRESSURE ( CPAP ) DEVICES 100 J298 ASSIST PHYSICIAN IN...PRESSURE VENTILATORS 61 COMPUTERIZED PULMONARY FUNCTION ANALYZERS 61 TREADMILLS 59 HOLTER MONITOR EQUIPMENT 57 CPAP EQUIPMENT 54 PRESSURE REGULATORS 48...SUCTIONING PROCEDURES 95 J321 SET UP CONTINUOUS POSITIVE AIRWAY PRESSURE ( CPAP ) DEVICES 95 J332 SET UP VOLUME VENTILATORS 93 F148 PERFORM ARTERIAL PUNCTURES 93
Real-Time GPS Monitoring for Earthquake Rapid Assessment in the San Francisco Bay Area
NASA Astrophysics Data System (ADS)
Guillemot, C.; Langbein, J. O.; Murray, J. R.
2012-12-01
The U.S. Geological Survey Earthquake Science Center has deployed a network of eight real-time Global Positioning System (GPS) stations in the San Francisco Bay area and is implementing software applications to continuously evaluate the status of the deformation within the network. Real-time monitoring of the station positions is expected to provide valuable information for rapidly estimating source parameters should a large earthquake occur in the San Francisco Bay area. Because earthquake response applications require robust data access, as a first step we have developed a suite of web-based applications which are now routinely used to monitor the network's operational status and data streaming performance. The web tools provide continuously updated displays of important telemetry parameters such as data latency and receive rates, as well as source voltage and temperature information within each instrument enclosure. Automated software on the backend uses the streaming performance data to mitigate the impact of outages, radio interference and bandwidth congestion on deformation monitoring operations. A separate set of software applications manages the recovery of lost data due to faulty communication links. Displacement estimates are computed in real-time for various combinations of USGS, Plate Boundary Observatory (PBO) and Bay Area Regional Deformation (BARD) network stations. We are currently comparing results from two software packages (one commercial and one open-source) used to process 1-Hz data on the fly and produce estimates of differential positions. The continuous monitoring of telemetry makes it possible to tune the network to minimize the impact of transient interruptions of the data flow, from one or more stations, on the estimated positions. Ongoing work is focused on using data streaming performance history to optimize the quality of the position, reduce drift and outliers by switching to the best set of stations within the network, and automatically select the "next best" station to use as reference. We are also working towards minimizing the loss of streamed data during concurrent data downloads by improving file management on the GPS receivers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous parameter monitoring systems and is the data collection... parameter monitoring systems and is the data collection requirement enforceable? (a) Where continuous parameter monitoring systems are used, obtain 1-hour arithmetic averages for three parameters: (1) Load...
7 CFR 3015.93 - Significant developments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Significant developments. 3015.93 Section 3015.93 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Monitoring and Reporting Program Performance...
77 FR 71171 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-29
... DHSS/DHIMS Information Systems User Satisfaction Survey, 0720-TBD. Needs and Uses: The information... (DHIMS) in a repeatable process for continued monitoring of user satisfaction using established... will determine user satisfaction with overall ease of use, access to information needed to perform...
GPS Monitor Station Upgrade Program at the Naval Research Laboratory
NASA Technical Reports Server (NTRS)
Galysh, Ivan J.; Craig, Dwin M.
1996-01-01
One of the measurements made by the Global Positioning System (GPS) monitor stations is to measure the continuous pseudo-range of all the passing GPS satellites. The pseudo-range contains GPS and monitor station clock errors as well as GPS satellite navigation errors. Currently the time at the GPS monitor station is obtained from the GPS constellation and has an inherent inaccuracy as a result. Improved timing accuracy at the GPS monitoring stations will improve GPS performance. The US Naval Research Laboratory (NRL) is developing hardware and software for the GPS monitor station upgrade program to improve the monitor station clock accuracy. This upgrade will allow a method independent of the GPS satellite constellation of measuring and correcting monitor station time to US Naval Observatory (USNO) time. THe hardware consists of a high performance atomic cesium frequency standard (CFS) and a computer which is used to ensemble the CFS with the two CFS's currently located at the monitor station by use of a dual-mixer system. The dual-mixer system achieves phase measurements between the high-performance CFS and the existing monitor station CFS's to within 400 femtoseconds. Time transfer between USNO and a given monitor station is achieved via a two way satellite time transfer modem. The computer at the monitor station disciplines the CFS based on a comparison of one pulse per second sent from the master site at USNO. The monitor station computer is also used to perform housekeeping functions, as well as recording the health status of all three CFS's. This information is sent to the USNO through the time transfer modem. Laboratory time synchronization results in the sub nanosecond range have been observed and the ability to maintain the monitor station CFS frequency to within 3.0 x 10 (sup minus 14) of the master site at USNO.
Xu, Wei; Riley, Erin A; Austin, Elena; Sasakura, Miyoko; Schaal, Lanae; Gould, Timothy R; Hartin, Kris; Simpson, Christopher D; Sampson, Paul D; Yost, Michael G; Larson, Timothy V; Xiu, Guangli; Vedal, Sverre
2017-03-01
Air pollution exposure prediction models can make use of many types of air monitoring data. Fixed location passive samples typically measure concentrations averaged over several days to weeks. Mobile monitoring data can generate near continuous concentration measurements. It is not known whether mobile monitoring data are suitable for generating well-performing exposure prediction models or how they compare with other types of monitoring data in generating exposure models. Measurements from fixed site passive samplers and mobile monitoring platform were made over a 2-week period in Baltimore in the summer and winter months in 2012. Performance of exposure prediction models for long-term nitrogen oxides (NO X ) and ozone (O 3 ) concentrations were compared using a state-of-the-art approach for model development based on land use regression (LUR) and geostatistical smoothing. Model performance was evaluated using leave-one-out cross-validation (LOOCV). Models performed well using the mobile peak traffic monitoring data for both NO X and O 3 , with LOOCV R 2 s of 0.70 and 0.71, respectively, in the summer, and 0.90 and 0.58, respectively, in the winter. Models using 2-week passive samples for NO X had LOOCV R 2 s of 0.60 and 0.65 in the summer and winter months, respectively. The passive badge sampling data were not adequate for developing models for O 3 . Mobile air monitoring data can be used to successfully build well-performing LUR exposure prediction models for NO X and O 3 and are a better source of data for these models than 2-week passive badge data.
Moser, Othmar; Mader, Julia K; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Koehler, Gerd; Messerschmidt, Janin; Hofmann, Peter
2016-08-10
Continuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP₁), and 5% below the second lactate turn point (LTP₂) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05). In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (-3.44, 5.15) mmol·L(-1), -0.45 (-3.95, 3.05) mmol·L(-1), -0.31 (-8.83, 8.20) mmol·L(-1) and at 1.17 (-2.06, 4.40) mmol·L(-1), 0.11 (-5.79, 6.01) mmol·L(-1), 1.48 (-2.60, 5.57) mmol·L(-1) in HIIE for the same intensities. Clinically-acceptable results (except for CON H) were found. CGM estimated BG to be clinically acceptable, except for CON H. Additionally, using CGM may increase avoidance of exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise.
Wood, Martin James; McMillen, Jason
2014-01-01
This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique.
McMillen, Jason
2014-01-01
Objective This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Methods Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Results Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. Conclusion The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. PMID:25694919
NASA Astrophysics Data System (ADS)
Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Gaul, Andrew; Jager, Simon; Desgeorges, Yohann
2012-04-01
An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight non-composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of approximately 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The analysis of monitoring results starts with a discussion of the monitoring of long-term deformations. Next, the assessment of the floor vibration serviceability performance is outlined. Then, the forced vibration tests conducted on the whole building at different construction stages are reviewed. The system identification results from seismic shaking records are also discussed. Finally, updating of a finite element model of the building is conducted.
Design and implementation of a remote UAV-based mobile health monitoring system
NASA Astrophysics Data System (ADS)
Li, Songwei; Wan, Yan; Fu, Shengli; Liu, Mushuang; Wu, H. Felix
2017-04-01
Unmanned aerial vehicles (UAVs) play increasing roles in structure health monitoring. With growing mobility in modern Internet-of-Things (IoT) applications, the health monitoring of mobile structures becomes an emerging application. In this paper, we develop a UAV-carried vision-based monitoring system that allows a UAV to continuously track and monitor a mobile infrastructure and transmit back the monitoring information in real- time from a remote location. The monitoring system uses a simple UAV-mounted camera and requires only a single feature located on the mobile infrastructure for target detection and tracking. The computation-effective vision-based tracking solution based on a single feature is an improvement over existing vision-based lead-follower tracking systems that either have poor tracking performance due to the use of a single feature, or have improved tracking performance at a cost of the usage of multiple features. In addition, a UAV-carried aerial networking infrastructure using directional antennas is used to enable robust real-time transmission of monitoring video streams over a long distance. Automatic heading control is used to self-align headings of directional antennas to enable robust communication in mobility. Compared to existing omni-communication systems, the directional communication solution significantly increases the operation range of remote monitoring systems. In this paper, we develop the integrated modeling framework of camera and mobile platforms, design the tracking algorithm, develop a testbed of UAVs and mobile platforms, and evaluate system performance through both simulation studies and field tests.
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2013 CFR
2013-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2012 CFR
2012-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2014 CFR
2014-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Monitoring continued equivalence. 26.45 Section 26...
21 CFR 26.45 - Monitoring continued equivalence.
Code of Federal Regulations, 2011 CFR
2011-04-01
... COMMUNITY Specific Sector Provisions for Medical Devices § 26.45 Monitoring continued equivalence. Monitoring activities will be carried out in accordance with § 26.69. ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Monitoring continued equivalence. 26.45 Section 26...
40 CFR 75.40 - General demonstration requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTINUOUS EMISSION MONITORING Alternative Monitoring Systems § 75.40 General demonstration... continuous emission monitoring system may apply to the Administrator for approval of an alternative monitoring system (or system component) to determine average hourly emission data for SO2, NOX, and/or...
Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi
2013-07-01
Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and presented separately for clinically different categories, e.g., hypoglycemia, exercise, or night and day. © 2013 Diabetes Technology Society.
Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya
2018-01-01
Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.
Jung, Ho-Yeon; Kim, In-Ho; Jung, Hyung-Jo
2017-01-01
Cable structure is a major component of long-span bridges, such as cable-stayed and suspension bridges, and it transfers the main loads of bridges to the pylons. As these cable structures are exposed to continuous external loads, such as vehicle and wind loads, vibration control and continuous monitoring of the cable are required. In this study, an electromagnetic (EM) damper was designed and fabricated for vibration control and monitoring of the cable structure. EM dampers, also called regenerative dampers, consist of permanent magnets and coils. The electromagnetic force due to the relative motion between the coil and the permanent magnet can be used to control the vibration of the structure. The electrical energy can be used as a power source for the monitoring system. The effects of the design parameters of the damper were numerically analyzed and the damper was fabricated. The characteristics of the damper were analyzed with various external load changes. Finally, the vibration-control and energy-harvesting performances of the cable structure were evaluated through a hybrid simulation. The vibration-control and energy-harvesting performances for various loads were analyzed and the applicability to the cable structure of the EM damper was evaluated. PMID:29088077
Jung, Ho-Yeon; Kim, In-Ho; Jung, Hyung-Jo
2017-10-31
Cable structure is a major component of long-span bridges, such as cable-stayed and suspension bridges, and it transfers the main loads of bridges to the pylons. As these cable structures are exposed to continuous external loads, such as vehicle and wind loads, vibration control and continuous monitoring of the cable are required. In this study, an electromagnetic (EM) damper was designed and fabricated for vibration control and monitoring of the cable structure. EM dampers, also called regenerative dampers, consist of permanent magnets and coils. The electromagnetic force due to the relative motion between the coil and the permanent magnet can be used to control the vibration of the structure. The electrical energy can be used as a power source for the monitoring system. The effects of the design parameters of the damper were numerically analyzed and the damper was fabricated. The characteristics of the damper were analyzed with various external load changes. Finally, the vibration-control and energy-harvesting performances of the cable structure were evaluated through a hybrid simulation. The vibration-control and energy-harvesting performances for various loads were analyzed and the applicability to the cable structure of the EM damper was evaluated.
Klueh, Ulrike; Czajkowski, Caroline; Ludzinska, Izabela; Qiao, Yi; Frailey, Jackman; Kreutzer, Donald L.
2016-01-01
The accumulation of macrophages (MΦ) at the sensor-tissue interface is thought to be a major player in controlling tissue reactions and sensor performance in vivo. Nevertheless until recently no direct demonstration of the causal relationship between MΦ aggregation and loss of sensor function existed. Using a Continuous Glucose Monitoring (CGM) murine model we previously demonstrated that genetic deficiencies of MΦ or depletion of MΦ decreased MΦ accumulation at sensor implantation sites, which led to significantly enhanced CGM performance, when compared to normal mice. Additional studies in our laboratories have also demonstrated that MΦ can act as “metabolic sinks” by depleting glucose levels at the implanted sensors in vitro and in vivo. In the present study we extended these observations by demonstrating that MΦ chemokine (CCL2) and receptor (CCR2) knockout mice displayed a decrease in inflammation and MΦ recruitment at sensor implantation sites, when compared to normal mice. This decreased MΦ recruitment significantly enhanced CGM performance when compared to control mice. These studies demonstrated the importance of the CCL2 family of chemokines and related receptors in MΦ recruitment and sensor performance and suggest chemokine targets for enhancing CGM in vivo. PMID:27376197
a Continuous Health Monitoring Guided Wave Fmd System for Retrofit to Existing Offshore Oilrigs
NASA Astrophysics Data System (ADS)
Mijarez, R.; Solis, L.; Martinez, F.
2010-02-01
An automatic health monitoring guided wave flood member detection (FMD) system, for retrofit to existing offshore oilrigs is presented. The system employs a microcontroller piezoelectric (PZT) based transmitter and a receiver instrumentation package composed of a PZT 40 kHz ultrasound transducer and a digital signal processor (DSP) module connected to a PC via USB for monitoring purposes. The transmitter and receiver were attached, non-intrusively, to the external wall of a steel tube; 1 m×27 cm×2 mm. Experiments performed in the laboratory have successfully identified automatically flooded tubes.
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2014 CFR
2014-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
40 CFR 60.1230 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to the “Monitoring Requirements” in § 60.13. (c) You must monitor the oxygen (or carbon dioxide... systems must I install for gaseous pollutants? 60.1230 Section 60.1230 Protection of Environment... Continuous Emission Monitoring § 60.1230 What continuous emission monitoring systems must I install for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring data I must collect with my continuous emission monitoring systems and is the data collection... monitoring systems and is the data collection requirement enforceable? (a) Where continuous emission monitoring systems are required, obtain 1-hour arithmetic averages. Make sure the averages for sulfur dioxide...
Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W
2015-05-01
Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring and most recently toward insertable device monitoring for several years. Significant advantages and disadvantages pertaining to these monitoring options will be addressed in this review. Insertable cardiac monitors have several advantages over external monitoring techniques and may signify a clinical turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation.
NASA Astrophysics Data System (ADS)
Young, Li-Hao; Li, Chiao-Hsin; Lin, Ming-Yeng; Hwang, Bing-Fang; Hsu, Hui-Tsung; Chen, Yu-Cheng; Jung, Chau-Ren; Chen, Kuan-Chi; Cheng, Dung-Hung; Wang, Ven-Shing; Chiang, Hung-Che; Tsai, Perng-Jy
2016-11-01
To reduce sampling artifacts and to improve time-resolved measurements of inorganic aerosol system, a recently commercialized semi-continuous In-situ Gas and Aerosol Composition (IGAC) monitoring system was evaluated against a reference annular denuder system (ADS; denuder/two-stage filter pack) at a suburban site over a year, during which the average PM2.5 was 37.0 ± 24.8 μg/m3. A suite of eight ions SO42-, NO3-, Cl-, NH4+, Na+, K+, Ca2+ and Mg2+ and two gases SO2 and NH3 were the target species. In comparison to the reference ADS method, the IGAC performed well in measuring the major ions SO42-, NO3- and NH4+, and the SO2. For those species, the linear slopes, intercepts and R2 values between the two methods all passed the performance evaluation criteria outlined by earlier similar studies. The performance of IGAC on Cl-, Na+, K+ and NH3 was marginally acceptable, whereas Ca2+ and Mg2+ could not be properly evaluated due to the low concentrations (<0.2 μg/m3) and hence inadequate amount of sample size. The ionic balance of the hourly IGAC samples averaged very close to unity, as did the daily ADS samples, though the former was considerably more variable than the latter. The overall performance of the IGAC has been shown to be comparable to other similar monitors and its improvements are discussed.
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2014 CFR
2014-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Monitoring continued equivalence. 26.15 Section 26...
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2013 CFR
2013-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Monitoring continued equivalence. 26.15 Section 26...
21 CFR 26.15 - Monitoring continued equivalence.
Code of Federal Regulations, 2012 CFR
2012-04-01
... COMMUNITY Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.15 Monitoring continued equivalence. Monitoring activities for the purpose of maintaining equivalence shall include review... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Monitoring continued equivalence. 26.15 Section 26...
Vermeul, Vince R.; Strickland, Chris E.; Thorne, Paul D.; ...
2014-12-31
The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to 1) evaluate CO2 mass balance and 2) detect any unforeseen loss in CO2 containment. The monitoring program will include direct monitoring of the injection stream and reservoir, and early-leak-detection monitoring directly above the primary confining zone. It will also implement an adaptive monitoringmore » strategy whereby monitoring results are continually evaluated and the monitoring network is modified as required, including the option to drill additional wells in out-years. Wells will be monitored for changes in CO2 concentration and formation pressure, and other geochemical/isotopic signatures that provide indication of CO2 or brine leakage. Indirect geophysical monitoring technologies that were selected for implementation include passive seismic, integrated surface deformation, time-lapse gravity, and pulsed neutron capture logging. Near-surface monitoring approaches that have been initiated include surficial aquifer and surface- water monitoring, soil-gas monitoring, atmospheric monitoring, and hyperspectral data acquisition for assessment of vegetation conditions. Initially, only the collection of baseline data sets is planned; the need for additional near- surface monitoring will be continually evaluated throughout the design and operational phases of the project, and selected approaches may be reinstituted if conditions warrant. Given the current conceptual understanding of the subsurface environment, early and appreciable impacts to near-surface environments are not expected.« less
Use of a continuous glucose sensor in an extracorporeal life support circuit.
Steil, Garry M; Alexander, Jamin; Papas, Alexandra; Monica, Langer; Modi, Biren P; Piper, Hannah; Jaksic, Tom; Gottlieb, Rebecca; Agus, Michael S D
2011-01-01
Standard care for infants on extracorporeal life support (ECLS) relies on intermittent measurement of blood glucose (BG); however, this can lead to significant changes in BG that go unrecognized for several hours. The present study was designed to assess performance and clinical applicability of a subcutaneous glucose sensor technology modified for use as a blood-contacting sensor within the ECLS circuit. Twelve children, aged 3 years or less, requiring ECLS support were studied. Three continuous glucose sensors (Medtronic MiniMed) were inserted into hubs placed in line with the ECLS circuit. Blood glucose was assessed with a laboratory analyzer (BG(LAB); Bayer Rapidlab 860) approximately every 5 h (mean 4.9 ± 3.3 h) with more frequent samples obtained with a bedside monitor (HemoCue) as needed. Sensor current (I(SIG)) was transmitted to a laptop computer and retrospectively calibrated using BGLAB. Sensor performance was assessed by mean absolute relative difference (MARD), linear regression slope and intercept, and correlation, all with BGLAB as reference. The BGLAB averaged 107.6 ± 36.4 mg/dl (mean ± standard deviation) ranging from 58 to 366 mg/dl. The MARD was 11.4%, with linear regression slope (0.86 ± 0.030) and intercept (9.0 ± 3.2 mg/dl) different from 1 and 0, respectively (p < .05), and correlation (r² = 0.76; p < .001). The system was not associated with any adverse events, and placement and removal into the hubs was easily accomplished. Instances in which more frequent BG values were obtained using a bedside HemoCue (BGHEMO) monitor showed the sensor to respond rapidly to changes. We conclude that continuous sensors can be adapted for use in an ECLS circuit with accuracy similar to or better than that achieved with the subcutaneous site. Continuous glucose monitoring in this population can rapidly detect changes in BG that would not otherwise be observed. Further studies will be needed to assess the benefit of continuous glucose monitoring in this population. © 2010 Diabetes Technology Society.
Öztürk, Semi; Aktemur, Tuğba; Kalyoncuoğlu, Muhsin; Durmuş, Gündüz; Can, Mehmet
2017-04-01
A 52-year-old man complaining of persistent recurring chest pain at night underwent coronary angiogram at another institution. Normal coronaries were observed and he was discharged with muscle spasmolytic prescription. Since symptoms had continued, 24-hour Holter monitoring was ordered at our facility and results revealed huge ST elevation and polymorphic ventricular tachycardia. Cold pressor test performed in catheterization laboratory also resulted in ventricular tachycardia. Nifedipine was prescribed and follow-up Holter monitoring revealed no further vasospastic episodes. Utility of 24-hour Holter rhythm monitoring and cold pressor test in patients with recurrent chest pain at night is demonstrated in this report.
Biondi, Loredana; Pellicanò, Roberta; Caligiuri, Vincenzo; Nava, Donatella
2014-01-01
Food allergens are substances able to induce an abnormal immunological response in sensitive individuals. The presence of allergens in food must be reported in tables (Directive 2003/89/EC). In this study we report the data of a monitoring plan carried out in the Campania Region during the 2012 for the detection of allergens (ovoalbumine and β-lattoglobulin) in food of different origin. The analisys were performed by means of ELISA assays. The percentage of analyzes with the presence of allegens not declared on the label is 4.3%, out of a total of 208 analyzes. It is therefore important to continue monitoring activities by the competent Authorities. PMID:27800313
Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F
2016-06-01
Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.
Cistern and planter box monitoring in Camden, NJ revisited ...
The Camden County Municipal Utilities Authority installed green infrastructure Stormwater Control Measures at multiple locations around the city of Camden, NJ. The Stormwater Control Measures include raised downspout planter boxes and cisterns. EPA is monitoring a subset of the locations to document the performance of individual Stormwater Control Measures. The selected monitoring sites include two sets of raised downspout planter boxes and five cisterns. These Stormwater Control Measures are being monitored: to investigate their hydrologic performances, to document water consumption patterns of cisterns for a better understanding of the supply and demand relationship, and to analyze cistern water quality. The continuous electronic monitoring devices included time domain reflectometers, rain gauges and pressure transducers. EPA decided to monitor these Stormwater Control Measures for three years and second year monitoring is ongoing. Monitoring data present the internal water flow patterns and media saturation frequency of the raised planter boxes and the capture ratio, water use patterns and water quality analysis of cisterns. Second year monitoring shows larger capture ratio for cisterns compared to the first year data and higher metal concentration at one site. The high metal concentration was later resolved by flushing the cistern and resampling. The presentation will summarize the comparison between first and second year data, providing results from the
AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF FOUR MERCURY EMISSION SAMPLING SYSTEMS
CEMs - Tekran Instrument Corp. Series 3300 and Thermo Electron's Mercury Freedom System Continuous Emission Monitors (CEMs) for mercury are designed to determine total and/or chemically speciated vapor-phase mercury in combustion emissions. Performance for mercury CEMs are cont...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Scope. 3015.90 Section 3015.90 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Monitoring and Reporting Program Performance § 3015.90...
7 CFR 275.19 - Monitoring and evaluation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Corrective Action § 275.19... Project Area/Management Unit Corrective Action Plan is implemented and achieves the anticipated results...
Code of Federal Regulations, 2011 CFR
2011-07-01
... the units of the emission standard, or 5 parts per million dry volume absolute value of the mean... zero and span adjustments). Any such periods that you do not collect data using the continuous...
DOT National Transportation Integrated Search
2015-06-01
As part of designing, constructing, and maintaining the bridge infrastructure in : Iowa, the Iowa Department of Transportation (DOT) has, in recent years, focused : efforts on investigating the use of new high-performance materials, new design : conc...
Continuous Monitoring of Essential Tremor Using a Portable System Based on Smartwatch.
Zheng, Xiaochen; Vieira Campos, Alba; Ordieres-Meré, Joaquín; Balseiro, Jose; Labrador Marcos, Sergio; Aladro, Yolanda
2017-01-01
Essential tremor (ET) shows amplitude fluctuations throughout the day, presenting challenges in both clinical and treatment monitoring. Tremor severity is currently evaluated by validated rating scales, which only provide a timely and subjective assessment during a clinical visit. Motor sensors have shown favorable performances in quantifying tremor objectively. A new highly portable system was used to monitor tremor continuously during daily lives. It consists of a smartwatch with a triaxial accelerometer, a smartphone, and a remote server. An experiment was conducted involving eight ET patients. The average effective data collection time per patient was 26 (±6.05) hours. Fahn-Tolosa-Marin Tremor Rating Scale (FTMTRS) was adopted as the gold standard to classify tremor and to validate the performance of the system. Quantitative analysis of tremor severity on different time scales is validated. Significant correlations were observed between neurologist's FTMTRS and patient's FTMTRS auto-assessment scores ( r = 0.84; p = 0.009), between the device quantitative measures and the scores from the standardized assessments of neurologists ( r = 0.80; p = 0.005) and patient's auto-evaluation ( r = 0.97; p = 0.032), and between patient's FTMTRS auto-assessment scores day-to-day ( r = 0.87; p < 0.001). A graphical representation of four patients with different degrees of tremor was presented, and a representative system is proposed to summarize the tremor scoring at different time scales. This study demonstrates the feasibility of prolonged and continuous monitoring of tremor severity during daily activities by a highly portable non-restrictive system, a useful tool to analyze efficacy and effectiveness of treatment.
40 CFR 60.2939 - What continuous emission monitoring systems must I install?
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems must I install? 60.2939 Section 60.2939 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... and Qualification Monitoring § 60.2939 What continuous emission monitoring systems must I install? (a) You must install, calibrate, maintain, and operate continuous emission monitoring systems for carbon...
Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T
2017-07-01
Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.
[A design and study of a novel electronic device for cuff-pressure monitoring].
Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang
2017-06-01
To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P = 0.000), the drops below 20 cmH 2 O began at 8th hour; but when measured by electronic manometer, all the value stayed unchanged around the baseline in 24 hours (F = 0.511, P = 0.796). Compared with traditional mechanical manometer, cuff pressures monitored by our novel electronic manometer were steadier in both continuous and intermittent monitoring. The device is compact and convenient, and can provide a good solution for continuously monitor of the tracheal cuff pressure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix B or appendix F requirements to evaluate continuous emission monitoring systems? 62.15190 Section... evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix B or appendix F requirements to evaluate continuous emission monitoring systems? 62.15190 Section... evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission...
Low-Cost Space Hardware and Software
NASA Technical Reports Server (NTRS)
Shea, Bradley Franklin
2013-01-01
The goal of this project is to demonstrate and support the overall vision of NASA's Rocket University (RocketU) through the design of an electrical power system (EPS) monitor for implementation on RUBICS (Rocket University Broad Initiatives CubeSat), through the support for the CHREC (Center for High-Performance Reconfigurable Computing) Space Processor, and through FPGA (Field Programmable Gate Array) design. RocketU will continue to provide low-cost innovations even with continuous cuts to the budget.
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-01-01
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at −700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m. PMID:28475168
Deformation Monitoring of Waste-Rock-Backfilled Mining Gob for Ground Control.
Zhao, Tongbin; Zhang, Yubao; Zhang, Zhenyu; Li, Zhanhai; Ma, Shuqi
2017-05-05
Backfill mining is an effective option to mitigate ground subsidence, especially for mining under surface infrastructure, such as buildings, dams, rivers and railways. To evaluate its performance, continual long-term field monitoring of the deformation of backfilled gob is important to satisfy strict public scrutiny. Based on industrial Ethernet, a real-time monitoring system was established to monitor the deformation of waste-rock-backfilled gob at -700 m depth in the Tangshan coal mine, Hebei Province, China. The designed deformation sensors, based on a resistance transducer mechanism, were placed vertically between the roof and floor. Stress sensors were installed above square steel plates that were anchored to the floor strata. Meanwhile, data cables were protected by steel tubes in case of damage. The developed system continually harvested field data for three months. The results show that industrial Ethernet technology can be reliably used for long-term data transmission in complicated underground mining conditions. The monitoring reveals that the roof subsidence of the backfilled gob area can be categorized into four phases. The bearing load of the backfill developed gradually and simultaneously with the deformation of the roof strata, and started to be almost invariable when the mining face passed 97 m.
NASA Astrophysics Data System (ADS)
Lachance, R. L.; Gordley, L. L.; Marshall, B. T.; Fisher, J.; Paxton, G.; Gubeli, J. F.
2015-12-01
Currently there is no efficient and affordable way to monitor gas releases over small to large areas. We have demonstrated the ability to accurately measure key greenhouse and pollutant gasses with low cost solar observations using the breakthrough sensor technology called the "Pupil Imaging Gas Correlation", PIGC™, which provides size and complexity reduction while providing exceptional resolution and coverage for various gas sensing applications. It is a practical implementation of the well-known Gas Filter Correlation Radiometry (GFCR) technique used for the HALOE and MOPITT satellite instruments that were flown on successful NASA missions in the early 2000s. This strong space heritage brings performance and reliability to the ground instrument design. A methane (CH4) abundance sensitivity of 0.5% or better of ambient column with uncooled microbolometers has been demonstrated with 1 second direct solar observations. These under $10 k sensors can be deployed in precisely balanced autonomous grids to monitor the flow of chosen gasses, and infer their source locations. Measureable gases include CH4, 13CO2, N2O, NO, NH3, CO, H2S, HCN, HCl, HF, HDO and others. A single instrument operates in a dual operation mode, at no additional cost, for continuous (real-time 24/7) local area perimeter monitoring for the detection of leaks for safety & security needs, looking at an artificial light source (for example a simple 60 W light bulb placed 100 m away), while simultaneously allowing solar observation for quasi-continuous wide area total atmospheric column scanning (3-D) for environmental monitoring (fixed and mobile configurations). The second mode of operation continuously quantifies the concentration and flux of specific gases over different ground locations, determined the amount of targeted gas being released from the area or getting into the area from outside locations, allowing better tracking of plumes and identification of sources. This paper reviews the measurement technique, performance demonstration and grid deployment strategy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon dioxide...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2012 CFR
2012-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2014 CFR
2014-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2013 CFR
2013-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
40 CFR 60.1315 - Must I meet other requirements for continuous monitoring?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous monitoring? 60.1315 Section 60.1315 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Requirements § 60.1315 Must I meet other requirements for continuous monitoring? You must also monitor three... at the inlet of your particulate matter air pollution control device. (c) Carbon feed rate if...
The verification test was conducted oer a period of 30 days (October 1 to October 31, 2008) and involved the continuous operation of duplicate semi-continuous monitoring technologies at the Burdens Creek Air Monitoring Site, an existing ambient-air monitoring station located near...
A Demonstration of GPS Landslide Monitoring Using Online Positioning User Service (OPUS)
NASA Astrophysics Data System (ADS)
Wang, G.
2011-12-01
Global Positioning System (GPS) technologies have been frequently applied to landslide study, both as a complement, and as an alternative to conventional surveying methods. However, most applications of GPS for landslide monitoring have been limited to the academic community for research purposes. High-accuracy GPS has not been widely equipped in geotechnical companies and used by technicians. The main issue that limits the applications of GPS in the practice of high-accuracy landslide monitoring is the complexity of GPS data processing. This study demonstrated an approach using the Online Positioning User Service (OPUS) (http://www.ngs.noaa.gov/OPUS) provided by the National Geodetic Survey (NGS) of National Oceanic and Atmospheric Administration (NOAA) to process GPS data and conduct long-term landslide monitoring in the Puerto Rico and Virgin Islands Region. Continuous GPS data collected at a creeping landslide site during two years were used to evaluate different scenarios for landslide surveying: continuous or campaign, long duration or short duration, morning or afternoon (different weather conditions). OPUS uses Continuously Operating Reference Station (CORS) managed by NGS (http://www.ngs.noaa.giv/CORS/) as references and user data as a rover to solve a position. There are 19 CORS permanent GPS stations in the Puerto Rico and Virgin Islands region. The dense GPS network provides a precise and reliable reference frame for subcentimeter-accuracy landslide monitoring in this region. Our criterion for the accuracy was the root-mean-square (RMS) of OPUS solutions over a 2-year period with respect to true landslide displacement time series overt the same period. The true landslide displacements were derived from a single-baseline (130 m) GPS processing by using 24-hour continuous data. If continuous GPS surveying is performed in the field, then OPUS static processing can provide 0.6 cm horizontal and 1.1 cm vertical precision with few outliers. If repeated campaign-style surveying is performed in the field, then the choice of observation time window and duration are very important. In order to detect a suspected sliding mass and track the kinematics of a creeping landslide, sub-centimeter horizontal accuracy is often required. OPUS static solutions for sessions of 4 hours or longer and OPUS rapid-static solutions for sessions as short as 15 minutes can achieve accuracy at this level if data collection during extreme weather conditions is avoided, such as rainfall and storm time. This study also indicated that rainfall events can seriously degrade the performance of high-accuracy GPS. Field GPS landslide surveying should avoid rainfall time that is usually accompanied by thunderstorms and the passage of weather fronts.
Clark, Matthew T.; Calland, James Forrest; Enfield, Kyle B.; Voss, John D.; Lake, Douglas E.; Moorman, J. Randall
2017-01-01
Background Charted vital signs and laboratory results represent intermittent samples of a patient’s dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. Methods and findings We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Conclusions Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients and improve performance of conventional models that use only laboratory results and vital signs. PMID:28771487
Moss, Travis J; Clark, Matthew T; Calland, James Forrest; Enfield, Kyle B; Voss, John D; Lake, Douglas E; Moorman, J Randall
2017-01-01
Charted vital signs and laboratory results represent intermittent samples of a patient's dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients and improve performance of conventional models that use only laboratory results and vital signs.
Yamazaki, Masahiro; Hasegawa, Goji; Majima, Saori; Mitsuhashi, Kazuteru; Fukuda, Takuya; Iwase, Hiroya; Kadono, Mayuko; Asano, Mai; Senmaru, Takafumi; Tanaka, Muhei; Fukui, Michiaki; Nakamura, Naoto
2014-01-01
Hemoglobin A1c is the main treatment target for patients with type 2 diabetes. It has also been shown recently that postprandial glucose and daily glucose fluctuations affect the progression of diabetic complications and atherosclerotic damages. Continuous glucose monitoring was performed in patients with type 2 diabetes to evaluate the efficacy of repaglinide vs. glimepiride on postprandial glucose spikes and fluctuations. A total of 10 Japanese patients with type 2 diabetes treated with glimepiride monotherapy were enrolled. After observation period for 8 weeks, glimepiride was changed to repaglinide. Continuous glucose monitoring was performed whilst consuming calorie-restricted diets for two days at baseline and at the end of the 12-week trial. Blood and urine samples were collected for measurement of glucose control parameters and inflammatory and oxidative stress markers on the last day of taking either glimepiride or repaglinide. Nine patients completed the trial. Although the glucose control parameters were not significantly different between glimepiride and repaglinide, the mean amplitude of glycemic excursions measured by continuous glucose monitoring was significantly reduced by changing treatment from glimepiride to repaglinide. The levels of plasminogen activator inhibitor-1, high sensitivity C-reactive protein, and urinary 8-hydoroxydeoxyguanosine were reduced significantly by repaglinide treatment. These results suggest that repaglinide may decrease the risk of cardiovascular disease in type 2 diabetes by minimizing glucose fluctuations thereby reducing inflammation and oxidative stress.
Real-time improvement of continuous glucose monitoring accuracy: the smart sensor concept.
Facchinetti, Andrea; Sparacino, Giovanni; Guerra, Stefania; Luijf, Yoeri M; DeVries, J Hans; Mader, Julia K; Ellmerer, Martin; Benesch, Carsten; Heinemann, Lutz; Bruttomesso, Daniela; Avogaro, Angelo; Cobelli, Claudio
2013-04-01
Reliability of continuous glucose monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for hypo- and hyperglycemic events. The smart CGM (sCGM) sensor concept consists of a commercial CGM sensor whose output enters three software modules, able to work in real time, for denoising, enhancement, and prediction. These three software modules were recently presented in the CGM literature, and here we apply them to the Dexcom SEVEN Plus continuous glucose monitor. We assessed the performance of the sCGM on data collected in two trials, each containing 12 patients with type 1 diabetes. The denoising module improves the smoothness of the CGM time series by an average of ∼57%, the enhancement module reduces the mean absolute relative difference from 15.1 to 10.3%, increases by 12.6% the pairs of values falling in the A-zone of the Clarke error grid, and finally, the prediction module forecasts hypo- and hyperglycemic events an average of 14 min ahead of time. We have introduced and implemented the sCGM sensor concept. Analysis of data from 24 patients demonstrates that incorporation of suitable real-time signal processing algorithms for denoising, enhancement, and prediction can significantly improve the performance of CGM applications. This can be of great clinical impact for hypo- and hyperglycemic alert generation as well in artificial pancreas devices.
2014-01-01
Background Hemoglobin A1c is the main treatment target for patients with type 2 diabetes. It has also been shown recently that postprandial glucose and daily glucose fluctuations affect the progression of diabetic complications and atherosclerotic damages. Methods Continuous glucose monitoring was performed in patients with type 2 diabetes to evaluate the efficacy of repaglinide vs. glimepiride on postprandial glucose spikes and fluctuations. A total of 10 Japanese patients with type 2 diabetes treated with glimepiride monotherapy were enrolled. After observation period for 8 weeks, glimepiride was changed to repaglinide. Continuous glucose monitoring was performed whilst consuming calorie-restricted diets for two days at baseline and at the end of the 12-week trial. Blood and urine samples were collected for measurement of glucose control parameters and inflammatory and oxidative stress markers on the last day of taking either glimepiride or repaglinide. Results Nine patients completed the trial. Although the glucose control parameters were not significantly different between glimepiride and repaglinide, the mean amplitude of glycemic excursions measured by continuous glucose monitoring was significantly reduced by changing treatment from glimepiride to repaglinide. The levels of plasminogen activator inhibitor-1, high sensitivity C-reactive protein, and urinary 8-hydoroxydeoxyguanosine were reduced significantly by repaglinide treatment. Conclusion These results suggest that repaglinide may decrease the risk of cardiovascular disease in type 2 diabetes by minimizing glucose fluctuations thereby reducing inflammation and oxidative stress. PMID:24843385
Wetland Mitigation Monitoring at the Fernald Preserve - 13200
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, Jane; Bien, Stephanie; Decker, Ashlee
The U.S. Department of Energy is responsible for 7.2 hectares (17.8 acres) of mitigation wetland at the Fernald Preserve, Ohio. Remedial activities affected the wetlands, and mitigation plans were incorporated into site-wide ecological restoration planning. In 2008, the Fernald Natural Resource Trustees developed a comprehensive wetland mitigation monitoring approach to evaluate whether compensatory mitigation requirements have been met. The Fernald Preserve Wetland Mitigation Monitoring Plan provided a guideline for wetland evaluations. The Ohio Environmental Protection Agency (Ohio EPA) wetland mitigation monitoring protocols were adopted as the means for compensatory wetland evaluation. Design, hydrologic regime, vegetation, wildlife, and biogeochemistry were evaluatedmore » from 2009 to 2011. Evaluations showed mixed results when compared to the Ohio EPA performance standards. Results of vegetation monitoring varied, with the best results occurring in wetlands adjacent to forested areas. Amphibians, particularly ambystomatid salamanders, were observed in two areas adjacent to forested areas. Not all wetlands met vegetation performance standards and amphibian biodiversity metrics. However, Fernald mitigation wetlands showed substantially higher ratings compared to other mitigated wetlands in Ohio. Also, soil sampling results remain consistent with other Ohio mitigated wetlands. The performance standards are not intended to be 'pass/fail' criteria; rather, they are reference points for use in making decisions regarding future monitoring and maintenance. The Trustees approved the Fernald Preserve Wetland Mitigation Monitoring Report with the provision that long-term monitoring of the wetlands continues at the Fernald Preserve. (authors)« less
NASA Technical Reports Server (NTRS)
Briggs, Ryan M.; Frez, Clifford; Borgentun, Carl E.; Bagheri, Mahmood; Forouhar, Siamak; May, Randy D.
2014-01-01
Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-11
...Recent EPA gas audit results indicate that some gas cylinders used to calibrate continuous emission monitoring systems on stationary sources do not meet EPA's performance specification. Reviews of stack test reports in recent years indicate that some stack testers do not properly follow EPA test methods or do not correctly calculate test method results. Therefore, EPA is proposing to amend its Protocol Gas Verification Program (PGVP) and the minimum competency requirements for air emission testing (formerly air emission testing body requirements) to improve the accuracy of emissions data. EPA is also proposing to amend other sections of the Acid Rain Program continuous emission monitoring system regulations by adding and clarifying certain recordkeeping and reporting requirements, removing the provisions pertaining to mercury monitoring and reporting, removing certain requirements associated with a class-approved alternative monitoring system, disallowing the use of a particular quality assurance option in EPA Reference Method 7E, adding an incorporation by reference that was inadvertently left out of the January 24, 2008 final rule, and clarifying the language and applicability of certain provisions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
... 1219-AB64 Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust... to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. This extension gives... Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. In response...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2014 CFR
2014-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2012 CFR
2012-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
40 CFR 60.1720 - What continuous emission monitoring systems must I install for gaseous pollutants?
Code of Federal Regulations, 2013 CFR
2013-07-01
... systems must I install for gaseous pollutants? 60.1720 Section 60.1720 Protection of Environment... or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1720 What continuous..., maintain, and operate continuous emission monitoring systems for oxygen (or carbon dioxide), sulfur dioxide...
Analysis of vehicle classification and truck weight data of the New England states
DOT National Transportation Integrated Search
1998-09-01
This report is about a statistical analysis of 1995-96 classification and weigh in motion (WIM) data from 17 continuous traffic-monitoring sites in New England. It documents work performed by Oak Ridge National Laboratory in fulfillment of 'Analysis ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Site visits. 3015.94 Section 3015.94 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Monitoring and Reporting Program Performance § 3015.94 Site...
7 CFR 215.11 - Special responsibilities of State agencies.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 215.11 Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE CHILD NUTRITION PROGRAMS SPECIAL MILK PROGRAM FOR CHILDREN § 215.11... managerial personnel to administer the Program and monitor performance of schools and child-care institutions...
7 CFR 215.11 - Special responsibilities of State agencies.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 215.11 Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE CHILD NUTRITION PROGRAMS SPECIAL MILK PROGRAM FOR CHILDREN § 215.11... managerial personnel to administer the Program and monitor performance of schools and child-care institutions...
7 CFR 215.11 - Special responsibilities of State agencies.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 215.11 Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE CHILD NUTRITION PROGRAMS SPECIAL MILK PROGRAM FOR CHILDREN § 215.11... managerial personnel to administer the Program and monitor performance of schools and child-care institutions...
7 CFR 215.11 - Special responsibilities of State agencies.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 215.11 Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE CHILD NUTRITION PROGRAMS SPECIAL MILK PROGRAM FOR CHILDREN § 215.11... managerial personnel to administer the Program and monitor performance of schools and child-care institutions...
Code of Federal Regulations, 2010 CFR
2010-01-01
... (CONTINUED) TECHNICAL ASSISTANCE GRANTS Grant Application Processing § 1775.20 Reporting. (a) Grantees shall constantly monitor performance to ensure that time schedules are being met, projected work by time periods is..., results of activity); (2) Analysis of challenges or setbacks that occurred during the grant period; (3...
Military Performance and Health Monitoring in Extreme Environments
2009-10-01
radiation and wind to give a true temperature reading . At high ambient temperatures, in particular in combination with solar radiation, objects may...Equivital multi-sensor unit enabling the real-time, parallel and continuous assessment of EKG (and heart rate), respiration (and respiration rate), skin
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
Validation of the continuous glucose monitoring sensor in preterm infants.
Beardsall, K; Vanhaesebrouck, S; Ogilvy-Stuart, A L; Vanhole, C; VanWeissenbruch, M; Midgley, P; Thio, M; Cornette, L; Ossuetta, I; Palmer, C R; Iglesias, I; de Jong, M; Gill, B; de Zegher, F; Dunger, D B
2013-03-01
Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. An international multicentre randomised controlled trial. One hundred and eighty-eight very low birth weight control infants. Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. CGMS can provide information on trends in glucose control, and guidance on the need for blood glucose assessment. This highlights the potential use of CGMS in optimising glucose control in preterm infants.
Continuous CO2 gas monitoring to clarify natural pattern and artificial leakage signals
NASA Astrophysics Data System (ADS)
Joun, W.; Ha, S. W.; Joo, Y. J.; Lee, S. S.; Lee, K. K.
2017-12-01
Continuous CO2 gas monitoring at shallow aquifer is significant for early detection and immediate handling of an aquifer impacted by leaking CO2 gas from the sequestration reservoir. However, it is difficult to decide the origin of CO2 gas because detected CO2 includes not only leaked CO2 but also naturally emitted CO2. We performed CO2 injection and monitoring tests in a shallow aquifer. Before the injection of CO2 infused water, we have conducted continuous monitoring of multi-level soil CO2 gas concentration and physical parameters such as temperature, humidity, pressure, wind speed and direction, and precipitation. The monitoring data represented that CO2 gas concentrations in unsaturated soil zone borehole showed differences at depths and daily variation (360 to 6980 ppm volume). Based on the observed data at 5 m and 8 m depths, vertical flux of gas was calculated as 0.471 L/min (LPM) for inflow from 5 m to 8 m and 9.42E-2 LPM for outflow from 8 m to 5 m. The numerical and analytical models were used to calculate the vertical flux of gas and to compare with observations. The results showed that pressure-based modeling could not explain the rapid change of CO2 gas concentration in borehole. Acknowledgement Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2 Storage" from the KEITI (Project Number: 2014001810003)
Mortellaro, Mark; DeHennis, Andrew
2014-11-15
A continuous glucose monitoring (CGM) system consisting of a wireless, subcutaneously implantable glucose sensor and a body-worn transmitter is described and clinical performance over a 28 day implant period in 12 type 1 diabetic patients is reported. The implantable sensor is constructed of a fluorescent, boronic-acid based glucose indicating polymer coated onto a miniaturized, polymer-encased optical detection system. The external transmitter wirelessly communicates with and powers the sensor and contains Bluetooth capability for interfacing with a Smartphone application. The accuracy of 19 implanted sensors were evaluated over 28 days during 6 in-clinic sessions by comparing the CGM glucose values to venous blood glucose measurements taken every 15 min. Mean absolute relative difference (MARD) for all sensors was 11.6 ± 0.7%, and Clarke error grid analysis showed that 99% of paired data points were in the combined A and B zones. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
2014-01-01
Background Monitoring of intracranial pressure (ICP) is a cornerstone in the surveillance of neurosurgical patients. The ICP is measured against a baseline pressure (i.e. zero - or reference pressure). We have previously reported that baseline pressure errors (BPEs), manifested as spontaneous shift or drifts in baseline pressure, cause erroneous readings of mean ICP in individual patients. The objective of this study was to monitor the frequency and severity of BPEs. To this end, we performed a prospective, observational study monitoring the ICP from two separate ICP sensors (Sensors 1 and 2) placed in close proximity in the brain. We characterized BPEs as differences in mean ICP despite near to identical ICP waveform in Sensors 1 and 2. Methods The study enrolled patients with aneurysmal subarachnoid hemorrhage in need of continuous ICP monitoring as part of their intensive care management. The two sensors were placed close to each other in the brain parenchyma via the same burr hole. The monitoring was performed as long as needed from a clinical perspective and the ICP recordings were stored digitally for analysis. For every patient the mean ICP as well as the various ICP wave parameters of the two sensors were compared. Results Sixteen patients were monitored median 164 hours (ranges 70 – 364 hours). Major BPEs, as defined by marked differences in mean ICP despite similar ICP waveform, were seen in 9 of them (56%). The BPEs were of magnitudes that had the potential to alter patient management. Conclusions Baseline Pressure Errors (BPEs) occur in a significant number of patients undergoing continuous ICP monitoring and they may alter patient management. The current practice of measuring ICP against a baseline pressure does not comply with the concept of State of the Art. Monitoring of the ICP waves ought to become the new State of the Art as they are not influenced by BPEs. PMID:24472296
Performance of a Press-Lam bridge : a 5-year load-testing and monitoring program
D. S. Gromala; R. C. Moody; M. M. Sprinkel
1985-01-01
This paper summarizes the results of load tests on an experimental highway bridge erected and put into service on the George Washington National Forest in Virginia in 1977. The bridge, made entirely of Press-Lam, a laminated veneer lumber (LVL) product, was load tested 1 month, 1 year, and 5 years after erection. The bridge continues to perform quite well and,...
Field performance of timber bridges. 13, Mohawk Canal stress-laminated bridge
P. D. Hilbrich Lee; X. Lauderdale
The Mohawk Canal bridge was constructed in August 1994, just outside Roll, Arizona. It is a simple-span, double-lane, stress-laminated deck superstructure, approximately 6.4 m (21 ft) long and 10.4 m (34 ft) wide and constructed with Combination 16F-V3 Douglas Fir glued-laminated timber beam laminations. The performance of the bridge was monitored continuously for 2...
NASA Astrophysics Data System (ADS)
Hu, Zhan; Lenting, Walther; van der Wal, Daphne; Bouma, Tjeerd
2015-04-01
Tidal flat morphology is continuously shaped by hydrodynamic force, resulting in highly dynamic bed elevations. The knowledge of short-term bed-level changes is important both for understanding sediment transport processes as well as for assessing critical ecological processes such as e.g. vegetation recruitment chances on tidal flats. Due to the labour involved, manual discontinuous measurements lack the ability to continuously monitor bed-elevation changes. Existing methods for automated continuous monitoring of bed-level changes lack vertical accuracy (e.g., Photo-Electronic Erosion Pin sensor and resistive rod) or limited in spatial application by using expensive technology (e.g., acoustic bed level sensors). A method provides sufficient accuracy with a reasonable cost is needed. In light of this, a high-accuracy sensor (2 mm) for continuously measuring short-term Surface-Elevation Dynamics (SED-sensor) was developed. This SED-sensor makes use of photovoltaic cells and operates stand-alone using internal power supply and data logging system. The unit cost and the labour in deployments is therefore reduced, which facilitates monitoring with a number of units. In this study, the performance of a group of SED-sensors is tested against data obtained with precise manual measurements using traditional Sediment Erosion Bars (SEB). An excellent agreement between the two methods was obtained, indicating the accuracy and precision of the SED-sensors. Furthermore, to demonstrate how the SED-sensors can be used for measuring short-term bed-level dynamics, two SED-sensors were deployed for 1 month at two sites with contrasting wave exposure conditions. Daily bed-level changes were obtained including a severe storm erosion event. The difference in observed bed-level dynamics at both sites was statistically explained by their different hydrodynamic conditions. Thus, the stand-alone SED-sensor can be applied to monitor sediment surface dynamics with high vertical and temporal resolutions, which provides opportunities to pinpoint morphological responses to various forces in a number of environments (e.g. tidal flats, beaches, rivers and dunes).
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... 16, 2006 Monitoring § 60.2940 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous...
January 2012 Groundwater Sampling at the Gnome-Coach, New Mexico, Site (Data Validation Package)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Findlay, Richard C.
2012-12-01
Annual sampling was conducted January 18, 2012, to monitor groundwater for potential radionuclide contamination at the Gnome-Coach site in New Mexico. The sampling was performed as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351, continually updated). Well LRL-7 was not sampled per instruction from the lead. A duplicate sample was collected from well USGS-1 and water levels were measured in the monitoring wells onsite.
January 2011 Groundwater Sampling at the Gnome-Coach, New Mexico, Site (Data Validation Package)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Findlay, Richard C.
2011-11-01
Annual sampling was conducted January 19, 2011, to monitor groundwater for potential radionuclide contamination at the Gnome-Coach site in New Mexico. The sampling was performed as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351, continually updated). Well LRL-7 was not sampled per instruction from the lead. A duplicate sample was collected from well USGS-1.Water levels were measured in the monitoring wells onsite.
Brown, Rebecca; Johnstone, Edward D; Heazell, Alexander E P
2016-01-01
Continuous longer-term fetal monitoring has been proposed to address limitations of current technologies in the detection of fetal compromise. We aimed to assess professionals' views regarding current fetal-monitoring techniques and proposed longer-term continuous fetal monitoring. A questionnaire was designed and validated to assess obstetricians' and midwives' use of current fetal-monitoring techniques and their views towards continuous monitoring. 125 of 173 received responses (72% obstetricians, 28% midwives) were analysed. Professionals had the strongest views about supporting evidence for the most commonly employed fetal-monitoring techniques (maternal awareness of fetal movements, ultrasound assessment of fetal growth and umbilical artery Doppler). 45.1% of professionals agreed that a continuous monitoring device would be beneficial (versus 28.7% who disagreed); this perceived benefit was not influenced by professionals' views regarding current techniques or professional background. Professionals have limited experience of continuous fetal monitoring, but most respondents believed that it would increase maternal anxiety (64.3%) and would have concerns with its use in clinical practice (81.7%). Continuous fetal monitoring would be acceptable to the majority of professionals. However, development of these technologies must be accompanied by extended examination of professionals' and women's views to determine barriers to its introduction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... Combustion Units Constructed on or Before August 30, 1999 Model Rule-Continuous Emission Monitoring § 60.1735... to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... appendix F requirements to evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1735 Section 60.1735... systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or carbon dioxide) continuous emission monitoring system. Therefore...
Code of Federal Regulations, 2010 CFR
2010-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... appendix F requirements to evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or...
Nanotechnology in glucose monitoring: advances and challenges in the last 10 years.
Scognamiglio, Viviana
2013-09-15
In the last decades, a wide multitude of research activity has been focused on the development of biosensors for glucose monitoring, devoted to overcome the challenges associated with smart analytical performances with commercial implications. Crucial issues still nowadays elude biosensors to enter the market, such as sensitivity, stability, miniaturisation, continuous and in situ monitoring in a complex matrix. A noteworthy tendency of biosensor technology is likely to push towards nanotechnology, which allows to reduce dimensions at the nanoscale, consenting the construction of arrays for high throughput analysis with the integration of microfluidics, and enhancing the performance of the biological components by using new nanomaterials. This review aims to highlight current trends in biosensors for glucose monitoring based on nanotechnology, reporting widespread representative examples of the recent approaches for nanobiosensors over the past 10 years. Progress in nanotechnology for the development of biosensing systems for blood glucose level monitoring will be discussed, in view of their design and construction on the bases of the new materials offered by nanotechnology. Copyright © 2013 Elsevier B.V. All rights reserved.
No Evidence That Gratitude Enhances Neural Performance Monitoring or Conflict-Driven Control
Saunders, Blair; He, Frank F. H.; Inzlicht, Michael
2015-01-01
It has recently been suggested that gratitude can benefit self-regulation by reducing impulsivity during economic decision making. We tested if comparable benefits of gratitude are observed for neural performance monitoring and conflict-driven self-control. In a pre-post design, 61 participants were randomly assigned to either a gratitude or happiness condition, and then performed a pre-induction flanker task. Subsequently, participants recalled an autobiographical event where they had felt grateful or happy, followed by a post-induction flanker task. Despite closely following existing protocols, participants in the gratitude condition did not report elevated gratefulness compared to the happy group. In regard to self-control, we found no association between gratitude—operationalized by experimental condition or as a continuous predictor—and any control metric, including flanker interference, post-error adjustments, or neural monitoring (the error-related negativity, ERN). Thus, while gratitude might increase economic patience, such benefits may not generalize to conflict-driven control processes. PMID:26633830
No Evidence That Gratitude Enhances Neural Performance Monitoring or Conflict-Driven Control.
Saunders, Blair; He, Frank F H; Inzlicht, Michael
2015-01-01
It has recently been suggested that gratitude can benefit self-regulation by reducing impulsivity during economic decision making. We tested if comparable benefits of gratitude are observed for neural performance monitoring and conflict-driven self-control. In a pre-post design, 61 participants were randomly assigned to either a gratitude or happiness condition, and then performed a pre-induction flanker task. Subsequently, participants recalled an autobiographical event where they had felt grateful or happy, followed by a post-induction flanker task. Despite closely following existing protocols, participants in the gratitude condition did not report elevated gratefulness compared to the happy group. In regard to self-control, we found no association between gratitude--operationalized by experimental condition or as a continuous predictor--and any control metric, including flanker interference, post-error adjustments, or neural monitoring (the error-related negativity, ERN). Thus, while gratitude might increase economic patience, such benefits may not generalize to conflict-driven control processes.
Agelastos, Anthony; Allan, Benjamin; Brandt, Jim; ...
2016-05-18
A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring onmore » a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.« less
Glyph-based generic network visualization
NASA Astrophysics Data System (ADS)
Erbacher, Robert F.
2002-03-01
Network managers and system administrators have an enormous task set before them in this day of growing network usage. This is particularly true of e-commerce companies and others dependent on a computer network for their livelihood. Network managers and system administrators must monitor activity for intrusions and misuse while at the same time monitoring performance of the network. In this paper, we describe our visualization techniques for assisting in the monitoring of networks for both of these tasks. The goal of these visualization techniques is to integrate the visual representation of both network performance/usage as well as data relevant to intrusion detection. The main difficulties arise from the difference in the intrinsic data and layout needs of each of these tasks. Glyph based techniques are additionally used to indicate the representative values of the necessary data parameters over time. Additionally, our techniques are geared towards providing an environment that can be used continuously for constant real-time monitoring of the network environment.
Operations of cleanrooms during a forest fire including protocols and monitoring results
NASA Astrophysics Data System (ADS)
Matheson, Bruce A.; Egges, Joanne; Pirkey, Michael S.; Lobmeyer, Lynette D.
2012-10-01
Contamination-sensitive space flight hardware is typically built in cleanroom facilities in order to protect the hardware from particle contamination. Forest wildfires near the facilities greatly increase the number of particles and amount of vapors in the ambient outside air. Reasonable questions arise as to whether typical cleanroom facilities can adequately protect the hardware from these adverse environmental conditions. On Monday September 6, 2010 (Labor Day Holiday), a large wildfire ignited near the Boulder, Colorado Campus of Ball Aerospace. The fire was approximately 6 miles from the Boulder City limits. Smoke levels from the fire stayed very high in Boulder for the majority of the week after the fire began. Cleanroom operations were halted temporarily on contamination sensitive hardware, until particulate and non-volatile residue (NVR) sampling could be performed. Immediate monitoring showed little, if any effect on the cleanroom facilities, so programs were allowed to resume work while monitoring continued for several days and beyond in some cases. Little, if any, effect was ever noticed in the monitoring performed.
NASA Technical Reports Server (NTRS)
Wu, S. T.
2000-01-01
The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.
Moser, Othmar; Mader, Julia K.; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R.; Koehler, Gerd; Messerschmidt, Janin; Hofmann, Peter
2016-01-01
Continuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP1), and 5% below the second lactate turn point (LTP2) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05). In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (−3.44, 5.15) mmol·L−1, −0.45 (−3.95, 3.05) mmol·L−1, −0.31 (−8.83, 8.20) mmol·L−1 and at 1.17 (−2.06, 4.40) mmol·L−1, 0.11 (−5.79, 6.01) mmol·L−1, 1.48 (−2.60, 5.57) mmol·L−1 in HIIE for the same intensities. Clinically-acceptable results (except for CON H) were found. CGM estimated BG to be clinically acceptable, except for CON H. Additionally, using CGM may increase avoidance of exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise. PMID:27517956